WorldWideScience

Sample records for fast reactivity measurements

  1. Central Reactivity Measurements on Assemblies 1 and 3 of the Fast Reactor FR0

    International Nuclear Information System (INIS)

    Londen, S.O.

    1966-01-01

    The reactivity effects of small samples of various materials have been measured, by the period method at the core centre of Assemblies 1 and 3 of the fast zero power reactor FR0. For some materials the reactivity change as a function of sample size has also been determined experimentally. The core of Assembly 1 consisted only of uranium enriched to 20 % whereas the core of Assembly 3 was diluted with 30 % graphite. The results have been compared with calculated values obtained with a second-order transport-theoretical perturbation model and using differently shielded cross sections depending upon sample size. Qualitative agreement has generally been found, although discrepancies still exist. The spectrum perturbation caused by the experimental arrangement has been analyzed and found to be rather important

  2. Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID

    Directory of Open Access Journals (Sweden)

    V. Sinha

    2012-12-01

    Full Text Available The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH. Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF system ("pump-and-probe" or "flow reactor" or the Comparative Reactivity Method (CRM with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS. Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID. Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques.

    Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s, sensitivity (LOD 3–6 s−1 and overall uncertainty (25% in optimum conditions for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests it

  3. The influence of spatial effects on the measurement results of reactivity in 'fast disturbances' of core parameters

    International Nuclear Information System (INIS)

    Tsyganov, S.V.; Shishkov, L.K.

    2001-01-01

    The analysis of methods for the determination of reactivity revealed an essential influence of spatial effect on the measurement precision. Using of reverse point kinetic equation for reactivity meter is assumed that the average neutron flux weigh with the importance function is known at every moment of the transient. In fact, reactivity meter represent behaviour of the neutron flux only of the part of the core, so measured value of reactivity can differ from really reactivity. Three-dimensional dynamic model of the core allow to evaluate such difference. It is supposed to evaluate correction factor for the neutron flux measured at the place where ion chamber situated with the three-dimensional model NOSTRA of the WWER core. On the basis of such algorithm we propose to build module allowing the influence of spatial effects on the results of the reactivity meter to be eliminated at real time regime. This code will be incorporated into the core monitoring system 'BLOK' (SCORPIO type) which is being developed for the Kola and Rostov NPP. The report illustrates utilization of such algorithm (Authors)

  4. Application of the Modified Source Multiplication (MSM) Technique to Subcritical Reactivity Worth Measurements in Thermal and Fast Reactor Systems

    International Nuclear Information System (INIS)

    Blaise, P.; Fougeras, Ph.; Mellier, F.

    2011-01-01

    The Amplified Source Multiplication (ASM) method and its improved Modified Source Multiplication (MSM) method have been widely used in the CEA's EOLE and MASURCA critical facilities over the past decades for the determination of reactivity worths by using fission chambers in subcritical configurations. The ASM methodology uses relatively simple relationships between count rates of efficient miniature fission chambers located in slightly subcritical reference and perturbed configurations. While this method works quite well for small reactivity variations, the raw results need to be corrected to take into account the flux perturbation at the fission chamber location. This is performed by applying to the measurement a correction factor called MSM. This paper describes in detail both methodologies, with their associated uncertainties. Applications on absorber cluster worth in the MISTRAL-4 full MOX mock-up core and the last core loaded in MASURCA show the importance of the MSM correction on raw ASM data. (authors)

  5. Automated reactivity anomaly surveillance in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.; Honeyman, D.J.; Shook, A.T.; Krohn, C.N.

    1985-01-01

    The automated technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and, thus, provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state

  6. Reactivity anomalies in the FFTF [Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.

    1987-04-01

    Experience using an automated core reactivity monitoring technique at the Fast Flux Test Facility (FFTF) through eight operating cycles is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. Reactivity worth predictions of core state changes (e.g., temperature and irradiation changes) and compensating control rod movements are required for the rod position comparison. A substantial data base now exists to evaluate changes in temperature reactivity feedback effects operational in the FFTF, rod worth changes due to core loading, temperature and irradiation effects and burnup effects associated with transmutation of fuel materials. This report summarizes preliminary work of correlating zero power and at-power rod worth measurement data, calculated burnup rates and rod worths using the latest ENDF/B-V cross section set for each cycle to evaluate the prediction models and attempt to resolve observed reactivity anomalies. 2 figs., 2 tabs

  7. Fast-scintillator measurements

    International Nuclear Information System (INIS)

    Graves, W.R.; Slaughter, D.R.; Lerche, R.A.

    1985-01-01

    The authors are investigating scintillators because their fast timing properties may be applied to the development of neutron diagnostics. Measuring the history of a target burn by direct observation of DT neutrons requires a time resolution of 20 ps. An instrument designed to measure the plasma ion temperature by neutron time of flight, when the flight path is less than or equal to 1m, requires a detector system with resolution of 60 to 100 ps. Fast plastic scintillators like NE111, BC-422, and SG180 typically have decay constants of about 1400 ps. With quenching, the decay constant can be decreased to about 700 ps - still to slow for the instruments that they would like to build. One yet-unexploited property of fast scintillators is their rise time. In 1984, they began experiments designed to measure scintillator rise times. For our application - the measurement of target burn histories - they are especially concerned with the temporal width of the sample excitation pulse, the temporal resolution of our measurement system, and the need to characterize the excitation pulse and the scintillator output simultaneously. Application of plastic scintillators to a neutron streak camera is described

  8. Fast and Objective MRTD measurement

    NARCIS (Netherlands)

    Jong, A.N. de; Bakker, S.J.M.

    1988-01-01

    Manufacturers and Users of the Thermal Imagers have spent very much time upon the definition and measurement of the generally accepted performance curve: MRTD (Minimum Resolvable Temperature Difference). The need for a cheap and fast, objective measurement method has considerably increased since the

  9. Reactivity changes in hybrid thermal-fast reactor systems during fast core flooding

    International Nuclear Information System (INIS)

    Pesic, M.

    1994-09-01

    A new space-dependent kinetic model in adiabatic approximation with local feedback reactivity parameters for reactivity determination in the coupled systems is proposed in this thesis. It is applied in the accident calculation of the 'HERBE' fast-thermal reactor system and compared to usual point kinetics model with core-averaged parameters. Advantages of the new model - more realistic picture of the reactor kinetics and dynamics during local large reactivity perturbation, under the same heat transfer conditions, are underlined. Calculated reactivity parameters of the new model are verified in the experiments performed at the 'HERBE' coupled core. The model has shown that the 'HERBE' safety system can shutdown reactor safely and fast even in the case of highly set power trip and even under conditions of big partial failure of the reactor safety system (author)

  10. Three-dimensional core analysis on a super fast reactor with negative local void reactivity

    International Nuclear Information System (INIS)

    Cao Liangzhi; Oka, Yoshiaki; Ishiwatari, Yuki; Ikejiri, Satoshi

    2009-01-01

    Keeping negative void reactivity throughout the cycle life is one of the most important requirements for the design of a supercritical water-cooled fast reactor (super fast reactor). Previous conceptual design has negative overall void reactivity. But the local void reactivity, which is defined as the reactivity change when the coolant of one fuel assembly disappears, also needs to be kept negative throughout the cycle life because the super fast reactor is designed with closed fuel assemblies. The mechanism of the local void reactivity is theoretically analyzed from the neutrons balance point of view. Three-dimensional neutronics/thermal-hydraulic coupling calculation is employed to analyze the characteristics of the super fast reactor including the local void reactivity. Some configurations of the core are optimized to decrease the local void reactivity. A reference core is successfully designed with keeping both overall and local void reactivity negative. The maximum local void reactivity is less than -30 pcm

  11. A digital instrument for reactivity measurements in a nuclear reactor

    International Nuclear Information System (INIS)

    Chwaszczewski, S.

    1979-01-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given. (author)

  12. [Fast neutron cross section measurements

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1992-01-01

    From its inception, the Nuclear Data Project at the University of Michigan has concentrated on two major objectives: (1) to carry out carefully controlled nuclear measurements of the highest possible reliability in support of the national nuclear data program, and (2) to provide an educational opportunity for students with interests in experimental nuclear science. The project has undergone a successful transition from a primary dependence on our photoneutron laboratory to one in which our current research is entirely based on a unique pulsed 14 MeV fast neutron facility. The new experimental facility is unique in its ability to provide nanosecond bursts of 14 MeV neutrons under conditions that are ''clean'' and as scatter-free as possible, and is the only one of its type currently in operation in the United States. It has been designed and put into operation primarily by graduate students, and has met or exceeded all of its important initial performance goals. We have reached the point of its routine operation, and most of the data are now in hand that will serve as the basis for the first two doctoral dissertations to be written by participating graduate students. Our initial results on double differential neutron cross sections will be presented at the May 1993 Fusion Reactor Technology Workshop. We are pleased to report that, after investing several years in equipment assembly and optimization, the project has now entered its ''data production'' phase

  13. Definition of reactivity and its measurability

    International Nuclear Information System (INIS)

    Hu Dapu

    1986-01-01

    Reactivity is the fundamental and important physical quantity in the reactor physics. The different kinds of method for defining reactivity are represented, the difference between different definitions of reactivity is indicalted and the conditions under which they have nearly the same measurable value are discussed. It is demonstrated that when the static adjointed neutron density or the neutron importance is selected to be a weight function for generating kinetic parameters used in the neutron kinetic equations, the kinetic reactivity is approximately equal to the static reactivity. Due to the constraint of the normalization condition, the shape function must be so selected that the corresponding amplitude function is proportional to the fundamental mode of neutron density variating with time. Measured reactivity by the kinetic method may vary with the position of detector, owing to the different space distribution of the prompt neutrons density and the delayed neutrons density and the effect of the higher harmonics of the neutron density. Some corresponding correction must be made in order to obtain the real static reactivity

  14. [Fast neutron cross section measurements

    International Nuclear Information System (INIS)

    1991-01-01

    In the 14 MeV Neutron Laboratory, we have continued the development of a facility that is now the only one of its kind in operation in the United States. We have refined the klystron bunching system described in last year's report to the point that 1.2 nanosecond pulses have been directly measured. We have tested the pulse shape discrimination capability of our primary NE 213 neutron detector. We have converted the RF sweeper section of the beamline to a frequency of 1 MHz to replace the function of the high voltage pulser described in last year's report which proved to be difficult to maintain and unreliable in its operation. We have also overcome several other significant experimental difficulties, including a major problem with a vacuum leak in the main accelerator column. We have completed additional testing to prove the remainder of the generation and measurement systems, but overcoming some of these experimental difficulties has delayed the start of actual data taking. We are now in a position to begin our first series of ring geometry elastic scattering measurements, and these will be underway before the end of the current contract year. As part of our longer term planning, we are continuing the conceptual analysis of several schemes to improve the intensity of our current pulsed beam. These include the provision of a duoplasmatron ion source and/or the provision of preacceleration bunching. Additional details are given later in this report. A series of measurements were carried out at the Tandem Dynamatron Facility involving the irradiation of a series of yttrium foils and the determination of activation cross sections using absolute counting techniques. The experimental work has been completed, and final analysis of the cross section data will be completed within several months

  15. Reactivity Measurement and Analysis System (RMAS-7)

    Energy Technology Data Exchange (ETDEWEB)

    Cordero, D.; Izquierdo, J.

    2015-07-01

    This paper tries to describe the Reactivity Measurement and Analysis System 7 (RMAS-7), which is an Areva’s hardware and software solution capable of accomplishing the physic startup tests in a work shift. RMAS-7 is a modular solution designed to be a powerful, convenient data collection and analysis system based on Ethernet communication network. This last feature allows RMAS-7 to have a distributed architecture. (Author)

  16. IAEA Technical Meeting on Innovative Fast Reactor Designs with Enhanced Negative Reactivity Feedback Features. Presentations

    International Nuclear Information System (INIS)

    2012-01-01

    The objective of the TM is to review and discuss the safety characteristics and the performances of the core of innovative fast reactor concepts, as well as to present the ongoing R&D activities in the area of core design and advanced simulation tools and methods for fast reactor core physics analysis. The focus is on fast spectrum cores optimized for actinide utilization and transmutation and, in particular, on core designs with enhanced negative reactivity feedback effects

  17. IAEA Technical Meeting on Innovative Fast Reactor Designs with Enhanced Negative Reactivity Feedback Features. Working Material

    International Nuclear Information System (INIS)

    2012-01-01

    The objective of the TM was to review and discuss the safety characteristics and the performances of the core of innovative fast reactor concepts, as well as to present the ongoing R&D activities in the area of core design and advanced simulation tools and methods for fast reactor core physics analysis. The focus was on fast spectrum cores optimized for actinide utilization and transmutation and, in particular, on core designs with enhanced negative reactivity feedback effects

  18. Fast Flux Test Facility (FFTF) feedback reactivity components

    International Nuclear Information System (INIS)

    Nguyen, D.H.

    1988-04-01

    The static tests conducted during Cycle 8A (1986) of the FFTF have allowed, for the first time, the experimental determination of each of the feedback reactivities caused by the following mechanisms: fuel axial expansion, control rod repositioning, core radial expansion, and subassembly bowing. A semiempirical equation was obtained to describe each of these feedback components that depended only on the relevant reactor temperature (bowing was presented in a tabular form). The Doppler and sodium density reactivities were calculated using existing mechanistic methods. Although they could also be fitted with closed-form equations depending only on temperatures, these equations are not needed in transient analyses using whole core safety computer codes, which use mechanistic methods. The static feedback reactivity model was extended to obtain a dynamic model via the concept of ''time constants.'' Besides being used for transient analyses in the FFTF, these feedback equations constitute a database for the validation and/or calibration of mechanistic feedback reactivity models. 2 refs., 6 tabs

  19. Fast response densitometer for measuring liquid density

    Science.gov (United States)

    1972-01-01

    Densitometer was developed which produces linear voltage proportional to changes in density of flowing liquid hydrogen. Unit has fast response time and good system stability, statistical variation, and thermal equilibrium. System accuracy is 2 percent of total density span. Basic design may be altered to include measurement of other flowing materials.

  20. A miniaturized technique for assessing protein thermodynamics and function using fast determination of quantitative cysteine reactivity.

    Science.gov (United States)

    Isom, Daniel G; Marguet, Philippe R; Oas, Terrence G; Hellinga, Homme W

    2011-04-01

    Protein thermodynamic stability is a fundamental physical characteristic that determines biological function. Furthermore, alteration of thermodynamic stability by macromolecular interactions or biochemical modifications is a powerful tool for assessing the relationship between protein structure, stability, and biological function. High-throughput approaches for quantifying protein stability are beginning to emerge that enable thermodynamic measurements on small amounts of material, in short periods of time, and using readily accessible instrumentation. Here we present such a method, fast quantitative cysteine reactivity, which exploits the linkage between protein stability, sidechain protection by protein structure, and structural dynamics to characterize the thermodynamic and kinetic properties of proteins. In this approach, the reaction of a protected cysteine and thiol-reactive fluorogenic indicator is monitored over a gradient of temperatures after a short incubation time. These labeling data can be used to determine the midpoint of thermal unfolding, measure the temperature dependence of protein stability, quantify ligand-binding affinity, and, under certain conditions, estimate folding rate constants. Here, we demonstrate the fQCR method by characterizing these thermodynamic and kinetic properties for variants of Staphylococcal nuclease and E. coli ribose-binding protein engineered to contain single, protected cysteines. These straightforward, information-rich experiments are likely to find applications in protein engineering and functional genomics. Copyright © 2010 Wiley-Liss, Inc.

  1. Fast measure proceeding of weak currents

    International Nuclear Information System (INIS)

    Taieb, J.

    1953-01-01

    The process of fast measure of the weak currents that we are going to describe briefly apply worthy of the provided currents by the sources to elevated value internal resistance, as it is the case for the ionization chamber, the photocells, mass spectroscopic tubes. The problem to measure weak currents is essentially a problem of amplifier and of input circuit. We intended to achieve a whole amplifier and input circuit with advanced performances, meaning that for a measured celerity we wanted to have an signal/noise ratio the most important as in the classic systems and for a same report signal/noise a more quickly done measure. (M.B.) [fr

  2. Application of a Virtual Reactivity Feedback Control Loop in Non-Nuclear Testing of a Fast Spectrum Reactor

    Science.gov (United States)

    Bragg-Sitton, Shannon M.; Forsbacka, Matthew

    2004-01-01

    For a compact, fast-spectrum reactor, reactivity feedback is dominated by core deformation at elevated temperature. Given the use of accurate deformation measurement techniques, it is possible to simulate nuclear feedback in non-nuclear electrically heated reactor tests. Implementation of simulated reactivity feedback in response to measured deflection is being tested at the NASA Marshall Space Flight Center Early Flight Fission Test Facility (EFF-TF). During tests of the SAFE-100 reactor prototype, core deflection was monitored using a high resolution camera. "virtual" reactivity feedback was accomplished by applying the results of Monte Carlo calculations (MCNPX) to core deflection measurements; the computational analysis was used to establish the reactivity worth of van'ous core deformations. The power delivered to the SAFE-100 prototype was then dusted accordingly via kinetics calculations, The work presented in this paper will demonstrate virtual reactivity feedback as core power was increased from 1 kilowatt(sub t), to 10 kilowatts(sub t), held approximately constant at 10 kilowatts (sub t), and then allowed to decrease based on the negative thermal reactivity coefficient.

  3. Fast figuring of large optics by reactive atom plasma

    Science.gov (United States)

    Castelli, Marco; Jourdain, Renaud; Morantz, Paul; Shore, Paul

    2012-09-01

    The next generation of ground-based astronomical observatories will require fabrication and maintenance of extremely large segmented mirrors tens of meters in diameter. At present, the large production of segments required by projects like E-ELT and TMT poses time frames and costs feasibility questions. This is principally due to a bottleneck stage in the optical fabrication chain: the final figuring step. State-of-the-art figure correction techniques, so far, have failed to meet the needs of the astronomical community for mass production of large, ultra-precise optical surfaces. In this context, Reactive Atom Plasma (RAP) is proposed as a candidate figuring process that combines nanometer level accuracy with high material removal rates. RAP is a form of plasma enhanced chemical etching at atmospheric pressure based on Inductively Coupled Plasma technology. The rapid figuring capability of the RAP process has already been proven on medium sized optical surfaces made of silicon based materials. In this paper, the figure correction of a 3 meters radius of curvature, 400 mm diameter spherical ULE mirror is presented. This work demonstrates the large scale figuring capability of the Reactive Atom Plasma process. The figuring is carried out by applying an in-house developed procedure that promotes rapid convergence. A 2.3 μm p-v initial figure error is removed within three iterations, for a total processing time of 2.5 hours. The same surface is then re-polished and the residual error corrected again down to λ/20 nm rms. These results highlight the possibility of figuring a metre-class mirror in about ten hours.

  4. Core concept of fast power reactor with zero sodium void reactivity

    International Nuclear Information System (INIS)

    Matveev, V.I.; Chebeskov, A.N.; Krivitsky, I.Y.

    1991-01-01

    The paper presents a core concept of BN-800 - type fast power reactor with zero sodium void reactivity (SVR). Consideration is given to the layout-and some design features of such a core. Some considerations on the determination of the required SVR value as one of the fast reactor safety criteria in accidents with coolant boiling are presented. Some methodical considerations an the development of calculation models that give a correct description of the new core features are stated. The results of the integral SVR calculation studies are included. reactivity excursions under different scenarios of sodium boiling are estimated, some corrections into the calculated SVR value are discussed. (author)

  5. Measurement of fast neutron background in SAGE

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S

    2002-01-01

    The spectrometer intended for direct measurements of ultra low fluxes of fast neutrons is described. It is sensitive to neutron fluxes of 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 and lower. The detection efficiency of fast neutrons with simultaneous energy measurement was determined from Monte-Carlo simulation to be equal to 0.11 +- 0.01. The background counting rate in the detector corresponds to a neutron flux of (6.5 +- 2.1) x 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The natural neutron flux from the surrounding mine rock at the depth of 4700 meters of water equivalent was measured to be (7.3 +- 2.4) x 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The flux of fast neutrons in the SAGE main room was measured to be < 2.3 x 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in 1.0-11.0 MeV energy range.

  6. Accurate reactivity void coefficient calculation for the fast spectrum reactor FBR-IME

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Fabiano P.C.; Vellozo, Sergio de O.; Velozo, Marta J., E-mail: fabianopetruceli@outlook.com, E-mail: vellozo@cbpf.br, E-mail: martajann@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Militar

    2017-07-01

    This paper aims to present an accurate calculation of the void reactivity coefficient for the FBR-IME, a fast spectrum reactor in development at the Engineering Military Institute (IME). The main design peculiarity lies in using mixed oxide [MOX - PuO{sub 2} + U(natural uranium)O{sub 2}] as fuel core. For this task, SCALE system was used to calculate the reactivity for several voids distributions generated by bubbles in the sodium beyond its boiling point. The results show that although the void reactivity coefficient is positive and location dependent, they are offset by other feedback effects, resulting in a negative overall coefficient. (author)

  7. SPARC fast reactor design : Design of two passively safe metal-fuelled sodium-cooled pool-type small modular fast reactors with Autonomous Reactivity Control

    OpenAIRE

    Lindström, Tobias

    2015-01-01

    In this master thesis a small modular sodium-cooled metal-fuelled pool-type fast reactor design, called SPARC - Safe and Passive with Autonomous Reactivity control, has been designed. The long term reactivity changes in the SPARC are managed by implementation of the the Autonomous Reactivity Control (ARC) system, which is the novelty of the design. The overall design is mainly based on the Integral Fast Reactor project (IFR), which experimentally demonstrated the passive safety characteristic...

  8. Enhanced fast digital integrator for magnetic measurements

    Science.gov (United States)

    Arpaia, P.; Cesaro, U.; Cimmino, P.

    2017-08-01

    An enhanced Fast Digital Integrator (eFDI) was prototyped to satisfy the new requirements arising from current on-field exploitation of the previous Fast Digital Integrator in magnetic measurements for particle accelerators at CERN. In particular, the prototype achieves improved performance in terms of offset (5 ppm on 10 V fullscale), self-calibration accuracy (1 ppm of residual error), and data throughput (100 MB/s), by simultaneously preserving high-level signal-to-noise and distortion ratio (SINAD 105 dB at 10 Hz). In this paper, initially, the specifications, the design solutions, and the main features of the eFDI are illustrated. Then, the experimental results of the metrological characterization are compared with the CERN state-of-the-art integrator FDI performance in order to highlight the achieved improvements.

  9. The Effect Of Beryllium Interaction With Fast Neutrons On the Reactivity Of ETRR-2 Research Reactor

    International Nuclear Information System (INIS)

    Aziz, M.; El Messiry, A.M.

    2000-01-01

    The effect of beryllium interactions with fast neutrons is studied for Etrr 2 research reactors. Isotope build up inside beryllium blocks is calculated under different irradiation times. a new model for the Etrr 2 research reactor is designed using MCNP code to calculate the reactivity and flux change of the reactor due to beryllium poison

  10. Effect of Fast Pyrolysis Conditions on Structural Transformation and Reactivity of Herbaceous Biomasses at High Temperatures

    DEFF Research Database (Denmark)

    Trubetskaya, Anna; Jensen, Anker D.; Jensen, Peter Arendt

    of organic and inorganic matter on the char structural transformations. The results indicate no influence of the free radicals on char reactivity and burnout. The formation of free radicals in fast pyrolysis is related to the differences in the ash composition, namely presence of K+ ions in the wheat straw...

  11. Small Sample Reactivity Measurements in the RRR/SEG Facility: Reanalysis using TRIPOLI-4

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, Andrew [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmiotti, Guiseppe [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    This work involved reanalyzing the RRR/SEG integral experiments performed at the Rossendorf facility in Germany throughout the 1970s and 80s. These small sample reactivity worth measurements were carried out using the pile oscillator technique for many different fission products, structural materials, and standards. The coupled fast-thermal system was designed such that the measurements would provide insight into elemental data, specifically the competing effects between neutron capture and scatter. Comparing the measured to calculated reactivity values can then provide adjustment criteria to ultimately improve nuclear data for fast reactor designs. Due to the extremely small reactivity effects measured (typically less than 1 pcm) and the specific heterogeneity of the core, the tool chosen for this analysis was TRIPOLI-4. This code allows for high fidelity 3-dimensional geometric modeling, and the most recent, unreleased version, is capable of exact perturbation theory.

  12. FBCT fast intensity measurement using TRIC cards

    CERN Document Server

    Allica, J C; Belohrad, D; Jensen, L; Lenardon, F; SØby, L

    2015-01-01

    At the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replaced by a fully digital system enclosed in a single VME based card. This new system called TRIC (Transformer Integration Card) is based on a 12 bit, 212 MS/s ADC and an FPGA for the signal processing. Also located on the same board one finds a 250 V/1.5 W DCDC converter used to generate precise calibration pulses.

  13. A Fast Digital Integrator for Magnetic Measurements

    CERN Document Server

    Spiezia, G

    2008-01-01

    In this work, the Fast Digitial Integrator (FDI), conceived for characterizing dynamic features of superconducting magnets and measuring fast transients of magnetic fields at the European Organization for Nuclear Research (CERN) and other high-energy physics research centres, is presented. FDI development was carried out inside a framework of cooperation between the group of Magnet Tests and Measurements of CERN and the Department of Engineering of the University of Sannio. Drawbacks related to measurement time decrease of main high-performance analog-to-digital architectures, such as Delta-Sigma and integrators, are overcome by founding the design on (i) a new generation of successive approximation converters, for high resolution (18-bit) at high rate (500 kS/s), (ii) a digital signal processor, for on-line down-sampling by integrating the input signal, (iii) a custom time base, based on a Universal Time Counter, for reducing time-domain uncertainty, and (iv) a PXI board, for high bus transfer rate, as well ...

  14. A Fast Reactive Power Optimization in Distribution Network Based on Large Random Matrix Theory and Data Analysis

    Directory of Open Access Journals (Sweden)

    Wanxing Sheng

    2016-05-01

    Full Text Available In this paper, a reactive power optimization method based on historical data is investigated to solve the dynamic reactive power optimization problem in distribution network. In order to reflect the variation of loads, network loads are represented in a form of random matrix. Load similarity (LS is defined to measure the degree of similarity between the loads in different days and the calculation method of the load similarity of load random matrix (LRM is presented. By calculating the load similarity between the forecasting random matrix and the random matrix of historical load, the historical reactive power optimization dispatching scheme that most matches the forecasting load can be found for reactive power control usage. The differences of daily load curves between working days and weekends in different seasons are considered in the proposed method. The proposed method is tested on a standard 14 nodes distribution network with three different types of load. The computational result demonstrates that the proposed method for reactive power optimization is fast, feasible and effective in distribution network.

  15. Modelling of power-reactivity coefficient measurement

    International Nuclear Information System (INIS)

    Strmensky, C.; Petenyi, V.; Jagrik, J.; Minarcin, M.; Hascik, R.; Toth, L.

    2005-01-01

    Report describes results of modeling of power-reactivity coefficient analysis on power-level. In paper we calculate values of discrepancies arisen during transient process. These discrepancies can be arisen as result of experiment evaluation and can be caused by disregard of 3D effects on neutron distribution. The results are critically discussed (Authors)

  16. Understanding the mechanism of catalytic fast pyrolysis by unveiling reactive intermediates in heterogeneous catalysis

    Science.gov (United States)

    Hemberger, Patrick; Custodis, Victoria B. F.; Bodi, Andras; Gerber, Thomas; van Bokhoven, Jeroen A.

    2017-06-01

    Catalytic fast pyrolysis is a promising way to convert lignin into fine chemicals and fuels, but current approaches lack selectivity and yield unsatisfactory conversion. Understanding the pyrolysis reaction mechanism at the molecular level may help to make this sustainable process more economic. Reactive intermediates are responsible for product branching and hold the key to unveiling these mechanisms, but are notoriously difficult to detect isomer-selectively. Here, we investigate the catalytic pyrolysis of guaiacol, a lignin model compound, using photoelectron photoion coincidence spectroscopy with synchrotron radiation, which allows for isomer-selective detection of reactive intermediates. In combination with ambient pressure pyrolysis, we identify fulvenone as the central reactive intermediate, generated by catalytic demethylation to catechol and subsequent dehydration. The fulvenone ketene is responsible for the phenol formation. This technique may open unique opportunities for isomer-resolved probing in catalysis, and holds the potential for achieving a mechanistic understanding of complex, real-life catalytic processes.

  17. Understanding the mechanism of catalytic fast pyrolysis by unveiling reactive intermediates in heterogeneous catalysis

    Science.gov (United States)

    Hemberger, Patrick; Custodis, Victoria B. F.; Bodi, Andras; Gerber, Thomas; van Bokhoven, Jeroen A.

    2017-01-01

    Catalytic fast pyrolysis is a promising way to convert lignin into fine chemicals and fuels, but current approaches lack selectivity and yield unsatisfactory conversion. Understanding the pyrolysis reaction mechanism at the molecular level may help to make this sustainable process more economic. Reactive intermediates are responsible for product branching and hold the key to unveiling these mechanisms, but are notoriously difficult to detect isomer-selectively. Here, we investigate the catalytic pyrolysis of guaiacol, a lignin model compound, using photoelectron photoion coincidence spectroscopy with synchrotron radiation, which allows for isomer-selective detection of reactive intermediates. In combination with ambient pressure pyrolysis, we identify fulvenone as the central reactive intermediate, generated by catalytic demethylation to catechol and subsequent dehydration. The fulvenone ketene is responsible for the phenol formation. This technique may open unique opportunities for isomer-resolved probing in catalysis, and holds the potential for achieving a mechanistic understanding of complex, real-life catalytic processes. PMID:28660882

  18. Non-equilibrium reactive flux: A unified framework for slow and fast reaction kinetics.

    Science.gov (United States)

    Bose, Amartya; Makri, Nancy

    2017-10-21

    The flux formulation of reaction rate theory is recast in terms of the expectation value of the reactive flux with an initial condition that corresponds to a non-equilibrium, factorized reactant density. In the common case of slow reactive processes, the non-equilibrium expression reaches the plateau regime only slightly slower than the equilibrium flux form. When the reactants are described by a single quantum state, as in the case of electron transfer reactions, the factorized reactant density describes the true initial condition of the reactive process. In such cases, the time integral of the non-equilibrium flux expression yields the reactant population as a function of time, allowing characterization of the dynamics in cases where there is no clear separation of time scales and thus a plateau regime cannot be identified. The non-equilibrium flux offers a unified approach to the kinetics of slow and fast chemical reactions and is ideally suited to mixed quantum-classical methods.

  19. Measurements of low reactivities using a reactor oscillator

    International Nuclear Information System (INIS)

    Obradovic, D.; Petrovic, M.

    1965-12-01

    Most of the methods of measuring reactivity are limited to the region from several hundreds to several thousands of pcm. The present work develops a method of measuring low reactivities from several pcm to about 600 pcm using the ROB-1 reactor oscillator on the RB reactor of the Boris Kidric Institute of Nuclear Sciences at Vinca. The accuracy of measurement is better than 1%. Several methods are used to measure low reactivities. The most often used is the method based on measuring the stable reactor period. The bottom limit of this method is about 30 porn /1,2/. For control rod calibration the method of rod oscillation is used /3,4/. This method is confronted with considerable influence of space effects /5/. Reference /6/ reports on a method for measuring the reactivity coefficient at a critical level in liquid-moderated reactors. The method is based on measuring reactor response to the oscillation of the moderator about the critical level. The present work reports on a method of determining the reactivity by measuring the phase shift between the perturbation of the effective multiplication factor and reactor response. With the use of the ROB-1 reactor oscillator, the method allows measurement of the reactivity from several pcm to about 600 pcm with an accuracy of 1% (author)

  20. Some calculations of sodium reactivity effects in a dilute fast reactor

    International Nuclear Information System (INIS)

    Codd, J.; Durston, C.; James, M.F.

    1962-04-01

    Exploratory calculations are made of the reactivity change due to loss of sodium coolant from a typical dilute fast reactor, with Pu O 2 - UO 2 - steel cermet fuel. The calculations refer to a simple spherical reactor model, and multigroup diffusion theory is used. The primary object of the investigation is to compare the predictions of three commonly used sets of multigroup constants, due to Lowenstein and Okrent (Argonne, 11 groups), Yiftah, Okrent and Moldauer (Argonne, 16 groups), and Hansen and Roach (Los Alamos, 16 groups). The results for the reactivity change obtained with these sets of constants are found to disagree in magnitude or sign. Analysis shows that resonance self-shielding in U 238 and Pu 239 below a few kev and capture in the 2.85 kev sodium resonance both have a large effect, but none of the sets allows for both phenomena. It is concluded that a necessary step towards the accurate prediction of sodium reactivity coefficients in dilute fast reactors will be the preparation of special multigroup constants below say 10 kev, which take account of both these resonance effects. This conclusion is in accord with the observation of Yiftah et al, that their multigroup set would require extension in order to apply to reactors containing an appreciable number of low energy neutrons. (author)

  1. Isothermal temperature reactivity coefficient measurement in TRIGA reactor

    International Nuclear Information System (INIS)

    Zagar, T.; Ravnik, M.; Trkov, A.

    2002-01-01

    Direct measurement of an isothermal temperature reactivity coefficient at room temperatures in TRIGA Mark II research reactor at Jozef Stefan Institute in Ljubljana is presented. Temperature reactivity coefficient was measured in the temperature range between 15 o C and 25 o C. All reactivity measurements were performed at almost zero reactor power to reduce or completely eliminate nuclear heating. Slow and steady temperature decrease was controlled using the reactor tank cooling system. In this way the temperatures of fuel, of moderator and of coolant were kept in equilibrium throughout the measurements. It was found out that TRIGA reactor core loaded with standard fuel elements with stainless steel cladding has small positive isothermal temperature reactivity coefficient in this temperature range.(author)

  2. Fast screening of analytes for chemical reactions by reactive low-temperature plasma ionization mass spectrometry.

    Science.gov (United States)

    Zhang, Wei; Huang, Guangming

    2015-11-15

    Approaches for analyte screening have been used to aid in the fine-tuning of chemical reactions. Herein, we present a simple and straightforward analyte screening method for chemical reactions via reactive low-temperature plasma ionization mass spectrometry (reactive LTP-MS). Solution-phase reagents deposited on sample substrates were desorbed into the vapor phase by action of the LTP and by thermal desorption. Treated with LTP, both reagents reacted through a vapor phase ion/molecule reaction to generate the product. Finally, protonated reagents and products were identified by LTP-MS. Reaction products from imine formation reaction, Eschweiler-Clarke methylation and the Eberlin reaction were detected via reactive LTP-MS. Products from the imine formation reaction with reagents substituted with different functional groups (26 out of 28 trials) were successfully screened in a time of 30 s each. Besides, two short-lived reactive intermediates of Eschweiler-Clarke methylation were also detected. LTP in this study serves both as an ambient ionization source for analyte identification (including reagents, intermediates and products) and as a means to produce reagent ions to assist gas-phase ion/molecule reactions. The present reactive LTP-MS method enables fast screening for several analytes from several chemical reactions, which possesses good reagent compatibility and the potential to perform high-throughput analyte screening. In addition, with the detection of various reactive intermediates (intermediates I and II of Eschweiler-Clarke methylation), the present method would also contribute to revealing and elucidating reaction mechanisms. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Synthesis and characterization of high wash fastness novel azo reactive dyes incorporating aromatic bridged diamines

    Directory of Open Access Journals (Sweden)

    Aamer Saeed

    2018-01-01

    Full Text Available A new series of azo reactive dyes containing free chlorine atoms have been synthesized. The synthetic methodology involves the diazotization of 4′4-diamino diphenylamine-2-sulfonic acid (2 followed by azo coupling with 1-amino-8-naphthol-3,6-disulfonic acid (3 in alkaline medium to yield intermediate dye (4. Condensation of the latter with 1,3,5-trichlorotriazine afforded the cyanurated dye (5. A number of novel bis aromatic diamines (1a–j were separately synthesized as bridging groups and were coupled with cyanurated dye (5 at room temperature to provide the target dyes designated as S1–S10 containing triazine and linker in a single molecule. The structures of newly synthesized compounds were confirmed by analytical data and spectroscopic techniques. The synthesized dyes were applied on cotton fibers to assess their light fastness, wash fastness and rubbing fastness and were found to possess medium to high fastness values in different dyes.

  4. Statistical measurements of fast changing electromagnetic fields

    NARCIS (Netherlands)

    Serra, Ramiro; Serra, Ramiro; Leferink, Frank Bernardus Johannes

    2010-01-01

    The present works aims at describing important statistical indexes such as the field uniformity, the field inhomogeneity and the statistics near the cavity walls for a special case of fast changing random electromagnetic fields. We generate this kind of electromagnetic environment by means of a

  5. Measurement of reactivity coefficients for code validation

    International Nuclear Information System (INIS)

    Nuding, Matthias; Loetsch, Thomas

    2005-01-01

    In the year 2003 measurements in the cold reactor state have been performed at the NPP KKI 2 in order to validate the codes that are used for reactor core calculations and especially for the proof of the shutdown margin that is produced by calculations only. For full power states code verification is quite easy because the calculations can be compared with different measured values, e.g. with the activation values determined by the aeroball system. For cold reactor states, however the data base is smaller, especially for reactor cores that are quite 'inhomogeneous' and have rather high Pu-fiss-and 235 U-contents. At the same time the cold reactor state is important regarding the shutdown margin. For these reasons the measurements mentioned above have been performed in order to check the accuracy of the codes that are used by the operator and by our organization for many years. Basically, boron concentrations and control rod worths for different configurations have been measured. The results of the calculation show a very good agreement with the measured values. Therefore, it can be stated that the operator's as well as our code system is suitable for routine use, e.g. during licensing procedures (Authors)

  6. Benchmark on traveling wave fast reactor with negative reactivity feedback obtained with MCNPX code

    International Nuclear Information System (INIS)

    Gann, V.V.; Gann, A.V.

    2012-01-01

    This paper presents results of computer simulations of traveling wave fast reactor with negative reactivity feedback. The results were obtained using MCNPX code combined with CINDER90 subroutine for depletion calculations. We considered 1-D model of TWR containing 4 m long core made of mixture of 66 at. % 238 U and 34 at. % 10 B. Ignitor made of 235 U was located in the center of the core. Boron was included as imitator of structural in-core materials and coolant. Negative reactivity feedback was adjusted to reactor power of 500 MW. In this case two burning waves originated from the igniter and travel to the ends of the core during the following 40 years; coefficient of utilization of 238 U reached 80 %. Distribution of specific power in traveling wave, isotope concentration of fission products and actinides, neutron flux, fast neutron spectrum, specific activity were calculated. Data of the computer simulation is in qualitative agreement with theoretical results obtained in slow burning wave approximation

  7. Measurement and analysis of reactivity worth of 237Np sample in cores of TCA and FCA

    International Nuclear Information System (INIS)

    Sakurai, Takeshi; Mori, Takamasa; Okajima, Shigeaki; Tani, Kazuhiro; Suzaki, Takenori; Saito, Masaki

    2009-01-01

    The reactivity worth of 22.87 grams of 237 Np oxide sample was measured and analyzed in seven uranium cores in the Tank-Type Critical Assembly (TCA) and two uranium cores in the Fast Critical Assembly (FCA) at the Japan Atomic Energy Agency. The TCA cores provided a systematic variation in the neutron spectrum between the thermal and resonance energy regions. The FCA cores, XXI and XXV, provided a hard neutron spectrum of the fast reactor and a soft one of the resonance energy region, respectively. Analyses were carried out using the JENDL-3.3 nuclear data library with a Monte Carlo method for the TCA cores and a deterministic method for the FCA cores. The ratios of calculated to experimental (C/E) reactivity worth were between 0.97 and 0.91, and showed no apparent dependence on the neutron spectrum. (author)

  8. Influence of void effects on reactivity of coupled fast-thermal system HERBE

    International Nuclear Information System (INIS)

    Ljubenov, V.; Milovanovic, S.; Milovanovic, T.; Cuknic, O.

    1997-01-01

    Coupled fast-thermal system HERBE at the experimental zero power heavy water reactor RB is a system with the significant effects of the neutron leakage and neutron absorption. Presence of a coolant void introduces a new structure in an extremely heterogeneous core. In those conditions satisfactory results of the calculation are acquired only using specified space-energy homogenization procedure. In order to analyze transient appearances and accidental cases of the reactor systems, a procedure for modeling of influence of moderator and coolant loss on reactivity ('void effect') is developed. Reduction of the moderator volume fraction in some fuel channels due to air gaps or steam generation during the accidental moderator boiling, restricts validity of the diffusion approximation in the reactor calculations. In cases of high neutron flux gradients, which are consequence of high neutron absorption, application of diffusion approximation is questionable too. The problem may be solved using transport or Monte Carlo methods, but they are not acceptable in the routine applications. Applying new techniques based on space-energy core homogenization, such as the SPH method or the discontinuity factor method, diffusion calculations become acceptable. Calculations based on the described model show that loss of part of moderator medium introduce negative reactivity in the HERBE system. Calculated local void reactivity coefficients are used in safety analysis of hypothetical accidents

  9. Measurement of reactivity effect caused by nonuniform fuel distribution

    International Nuclear Information System (INIS)

    Yamane, Yoshihiro; Hirano, Yasushi; Yasui, Hazime; Nishina, Kojiro; Shiroya, Seiji

    1991-01-01

    A reactivity effect due to a spatial variation of nuclear fuel concentration is an important problem in a reprocessing plant. To estimate this reactivity effect theoretically, the ''Goertzel's necessary condition, and th Fuel Importance'' theory have been proposed. In order to verify these theories, we have performed systematic measurements of reactivity effect due to the nonuniformity in the fuel distribution within the Kyoto University Critical Assembly. Neutron flux distribution and Fuel Importance distribution were also determined. A nonuniform assembly whose fuel concentration in the center region was 40% higher than the uniform one was found to have an excess reactivity of 0.3%Δk/k, with the same total uranium mass for which the uniform assembly was just critical. Moreover, its spatial distribution of thermal neutron flux and of Fuel Importance were more flat than those of the uniform assembly, as expected by the Goertzel's condition and the Fuel Importance theory. (Author)

  10. Space dependence of reactivity parameters on reactor dynamic perturbation measurements

    International Nuclear Information System (INIS)

    Maletti, R.; Ziegenbein, D.

    1985-01-01

    Practical application of reactor-dynamic perturbation measurements for on-power determination of differential reactivity weight of control rods and power coefficients of reactivity has shown a significant dependence of parameters on the position of outcore detectors. The space dependence of neutron flux signal in the core of a VVER-440-type reactor was measured by means of 60 self-powered neutron detectors. The greatest neutron flux alterations are located close to moved control rods and in height of the perturbation position. By means of computations, detector positions can be found in the core in which the one-point model is almost valid. (author)

  11. CYLFUX, Fast Reactor Reactivity Transients Simulation in LWR by 2-D 2 Group Diffusion

    International Nuclear Information System (INIS)

    Schmidt, A.

    1973-01-01

    1 - Nature of physical problem solved: A 2-dimensional calculation of the 2-group, space-dependent neutron diffusion equations is performed in r-z geometry using an arbitrary number of groups of delayed neutron precursors. The program is designed to simulate fast reactivity excursions in light water reactors taking into account Doppler feedback via adiabatic heatup of fuel. Axial motions of control rods may be considered including scram action on option. 2 - Method of solution: The differential equations are solved at each time step by an explicit finite difference method using two time levels. The stationary distributions are obtained by using the same algorithm. 3 - Restrictions on the complexity of the problem: No restriction to the number of space points and delayed neutron energy groups besides the computer size

  12. Fluxes of chemically reactive species inferred from mean concentration measurements

    NARCIS (Netherlands)

    Galmarini, S.; Vilà-Guerau De Arellano, J.; Duyzer, J.H.

    1997-01-01

    A method is presented for the calculation of the fluxes of chemically reactive species on the basis of routine measurements of meteorological variables and chemical species. The method takes explicity into account the influence of chemical reactions on the fluxes of the species. As a demonstration

  13. Measuring and monitoring KIPT Neutron Source Facility Reactivity

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yan [Argonne National Lab. (ANL), Argonne, IL (United States); Gohar, Yousry [Argonne National Lab. (ANL), Argonne, IL (United States); Zhong, Zhaopeng [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-08-01

    Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has keff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine the reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.

  14. A Fast and Robust Method for Measuring Optical Channel Gain

    DEFF Research Database (Denmark)

    Harbo, Anders La-Cour; Stoustrup, Jakob; Villemoes, L.F.

    2000-01-01

    We present a numerically stable and computational simple method for fast and robust measurement of optical channel gain. By transmitting adaptively designed signals through the channel, good accuracy is possible even in severe noise conditions......We present a numerically stable and computational simple method for fast and robust measurement of optical channel gain. By transmitting adaptively designed signals through the channel, good accuracy is possible even in severe noise conditions...

  15. Computer measurement system of reactor period for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1997-01-01

    The author simply introduces the hardware, principle, and software of the reactor period computer measure system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between Fission yield and Pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computer measure system makes the reactor period measurement into automation and intellectualization and also improves the speed and precision of period data process on-line

  16. The computerized reactor period measurement system for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1996-01-01

    The article simply introduces the hardware, principle, and software of the computerized reactor period measurement system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between fission yield and pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computerized measurement system makes the reactor period measurement into automatical and intelligent and also improves the speed and precision of period data on-line process

  17. Plasma turbulence measured by fast sweep reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Vermare, L.; Leclert, G.

    2004-01-01

    Traditionally devoted to electron density profile measurement we show that fast frequency sweeping reflectometry technique can bring valuable and innovative measurements onto plasma turbulence. While fast frequency sweeping technique is traditionally devoted to electron density radial profile measurements we show in this paper how we can handle the fluctuations of the reflected signal to recover plasma density fluctuation measurements with a high spatial and temporal resolution. Large size turbulence related to magneto-hydrodynamic (MHD) activity and the associated magnetic islands can be detected. The radial profile of the micro-turbulence, which is responsible for plasma anomalous transport processes, is experimentally determined through the fluctuation of the reflected phase signal. (authors)

  18. Plasma turbulence measured by fast sweep reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Vermare, L.; Heuraux, S.; Leclert, G.

    2004-01-01

    Traditionally devoted to electron density profile measurement we show that fast frequency sweeping reflectometry technique can bring valuable and innovative measurements onto plasma turbulence. While fast frequency sweeping technique is traditionally devoted to electron density radial profile measurements we show in this paper how we can handle the fluctuations of the reflected signal to recover plasma density fluctuation measurements with a high spatial and temporal resolution. Large size turbulence related to magneto-hydrodynamic (MHD) activity and the associated magnetic islands can be detected. The radial profile of the micro-turbulence, which is responsible for plasma anomalous transport processes, is experimentally determined through the fluctuation of the reflected phase signal

  19. Accuracy of single photoelectron time spread measurement of fast photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.

    1975-01-01

    The accuracy of time spread measurements of fast photomultipliers was investigated, using single photoelectrons. The effect of the finite light pulse width on the measurement accuracy was determined and discussed. Experimental data were obtained on a special measuring system for light pulse widths ranging from 200 psec to 10 nsec, using fast photomultipliers 8850 and C31024 with optimized operating conditions for minimum transit time spread. A modified exponential function expression and curve-fitting parameters are given, which fit closely the experimentally obtained data over a wide dynamic range of light pulse widths. (U.S.)

  20. Automated Measurement of Fast Mitochondrial Transport in Neurons

    Directory of Open Access Journals (Sweden)

    Kyle eMiller

    2015-11-01

    Full Text Available There is a growing recognition that fast mitochondrial transport in neurons is disrupted in multiple neurological diseases and psychiatric disorders. However a major constraint in identifying novel therapeutics based on mitochondrial transport is that the large-scale analysis of fast transport is time consuming. Here we describe methodologies for the automated analysis of fast mitochondrial transport from data acquired using a robotic microscope. We focused on addressing questions of measurement precision, speed, reliably, workflow ease, statistical processing and presentation. We used optical flow and particle tracking algorithms, implemented in ImageJ, to measure mitochondrial movement in primary cultured cortical and hippocampal neurons. With it, we are able to generate complete descriptions of movement profiles in an automated fashion of hundred of thousands of mitochondria with a processing time of approximately one hour. We describe the calibration of the parameters of the tracking algorithms and demonstrate that they are capable of measuring the fast transport of a single mitochondrion. We then show that the methods are capable of reliably measuring the inhibition of fast mitochondria transport induced by the disruption of microtubules with the drug nocodazole in both hippocampal and cortical neurons. This work lays the foundation for future large-scale screens designed to identify compounds that modulate mitochondrial motility.

  1. Detectors for timing measurements 2. Streak cameras and fast photodiodes

    International Nuclear Information System (INIS)

    Tanaka, Yoshihito; Adachi, Shin-ichi

    2009-01-01

    Measuring methods of the pulse structure and its stability of the synchrotron radiation, and the method of time resolving measurement by synchronizing the external signal with the synchrotron radiation pulse are explained. The synchrotron radiation pulse width ranges from some ten to some hundred pico-seconds, and the time resolution of the detectors should be better than some pico-seconds. The streak camera is such a fast detector. Instead of the streak camera which is large-scaled and expensive, fast photo-detectors can be employed to know entire time structures. Some examples of time-synchronized measurements using the streak camera and the fast photo-detector are presented. (K.Y.)

  2. Subcritical reactivity measurement at Angra 1 nuclear power plant

    International Nuclear Information System (INIS)

    Kuramoto, Renato Yoichi Ribeiro; Miranda, Anselmo Ferreira

    2011-01-01

    In order to speed up the Angra 1 NPP physics tests, this work intends to develop a digital reactivity meter combined with a methodology of the modified Neutron Source Multiplication (NSM) method with correction factors for subcriticality measurements at Angra 1 NPP. In the first part of this work, we have applied the Modified Neutron Source Multiplication (MNSM) Method with fundamental mode extraction, in order to improve the monitoring of the subcriticality at Angra 1 NPP during the criticality approach. In the second part, we developed a preliminary subcritical reactivity meter algorithm based on the point-reactor inverse kinetic model with six delayed neutron groups and external neutron source. The source strength was obtained through the Least Squares Inverse Kinetics Method (LSIKM). (author)

  3. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  4. Development and Investigation of Reactivity Measurement Methods in Subcritical Cores

    International Nuclear Information System (INIS)

    Wright, Johanna

    2005-05-01

    Subcriticality measurements during core loading and in future accelerator driven systems have a clear safety relevance. In this thesis two subcriticality methods are treated: the Feynman-alpha and the source modulation method. The Feynman-alpha method is a technique to determine the reactivity from the relative variance of the detector counts during a measurement period. The period length is varied to get the full time dependence of the variance-to-mean. The corresponding theoretical formula was known only with stationary sources. In this thesis, due to its relevance for novel reactivity measurement methods, the Feynman-alpha formulae for pulsed sources for both the stochastic and the deterministic cases are treated. Formulae neglecting as well as including the delayed neutrons are derived. The formulae neglecting delayed neutrons are experimentally verified with quite good agreement. The second reactivity measurement technique investigated in this thesis is the so-called source modulation technique. The theory of the method was elaborated on the assumption of point kinetics, but in practice the method will be applied by using the signal from a single local neutron detector. Applicability of the method therefore assumes point kinetic behaviour of the core. Hence, first the conditions of the point kinetic behaviour of subcritical cores was investigated. After that the performance of the source modulation technique in the general case as well as and in the limit of exact point kinetic behaviour was examined. We obtained the unexpected result that the method has a finite, non-negligible error even in the limit of point kinetic behaviour, and a substantial error in the operation range of future accelerator driven subcritical reactors (ADS). In practice therefore the method needs to be calibrated by some other method for on-line applications

  5. Development and Investigation of Reactivity Measurement Methods in Subcritical Cores

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Johanna

    2005-05-01

    Subcriticality measurements during core loading and in future accelerator driven systems have a clear safety relevance. In this thesis two subcriticality methods are treated: the Feynman-alpha and the source modulation method. The Feynman-alpha method is a technique to determine the reactivity from the relative variance of the detector counts during a measurement period. The period length is varied to get the full time dependence of the variance-to-mean. The corresponding theoretical formula was known only with stationary sources. In this thesis, due to its relevance for novel reactivity measurement methods, the Feynman-alpha formulae for pulsed sources for both the stochastic and the deterministic cases are treated. Formulae neglecting as well as including the delayed neutrons are derived. The formulae neglecting delayed neutrons are experimentally verified with quite good agreement. The second reactivity measurement technique investigated in this thesis is the so-called source modulation technique. The theory of the method was elaborated on the assumption of point kinetics, but in practice the method will be applied by using the signal from a single local neutron detector. Applicability of the method therefore assumes point kinetic behaviour of the core. Hence, first the conditions of the point kinetic behaviour of subcritical cores was investigated. After that the performance of the source modulation technique in the general case as well as and in the limit of exact point kinetic behaviour was examined. We obtained the unexpected result that the method has a finite, non-negligible error even in the limit of point kinetic behaviour, and a substantial error in the operation range of future accelerator driven subcritical reactors (ADS). In practice therefore the method needs to be calibrated by some other method for on-line applications.

  6. BENCHMARK EVALUATION OF THE INITIAL ISOTHERMAL PHYSICS MEASUREMENTS AT THE FAST FLUX TEST FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    John Darrell Bess

    2010-05-01

    The benchmark evaluation of the initial isothermal physics tests performed at the Fast Flux Test Facility, in support of Fuel Cycle Research and Development and Generation-IV activities at the Idaho National Laboratory, has been completed. The evaluation was performed using MCNP5 with ENDF/B-VII.0 nuclear data libraries and according to guidelines provided for inclusion in the International Reactor Physics Experiment Evaluation Project Handbook. Results provided include evaluation of the initial fully-loaded core critical, two neutron spectra measurements near the axial core center, 32 reactivity effects measurements (21 control rod worths, two control rod bank worths, six differential control rod worths, two shutdown margins, and one excess reactivity), isothermal temperature coefficient, and low-energy electron and gamma spectra measurements at the core center. All measurements were performed at 400 ºF. There was good agreement between the calculated and benchmark values for the fully-loaded core critical eigenvalue, reactivity effects measurements, and isothermal temperature coefficient. General agreement between benchmark experiment measurements and calculated spectra for neutrons and low-energy gammas at the core midplane exists, but calculations of the neutron spectra below the core and the low-energy gamma spectra at core midplane did not agree well. Homogenization of core components may have had a significant impact upon computational assessment of these effects. Future work includes development of a fully-heterogeneous model for comprehensive evaluation. The reactor physics measurement data can be used in nuclear data adjustment and validation of computational methods for advanced fuel cycle and nuclear reactor systems using Liquid Metal Fast Reactor technology.

  7. Skin test reactivity among Danish children measured 15 years apart

    DEFF Research Database (Denmark)

    Thomsen, SF; Ulrik, Charlotte Suppli; Porsbjerg, C

    2006-01-01

    BACKGROUND: Knowledge of secular trends in the prevalence of allergy among children stems in large part from questionnaire surveys, whereas repeated cross-sectional studies using objective markers of atopic sensitization are sparse. OBJECTIVES: To investigate whether the prevalence of skin prick...... (n = 527) and the second in 2001 (n = 480). Skin test reactivity to nine common aeroallergens was measured at both occasions. RESULTS: The prevalence of positive SPT to at least one allergen decreased from 24.1% in 1986 to 18.9% in 2001, (p = 0.05). We found a declining prevalence of sensitization...

  8. Delayed gamma power measurement for sodium-cooled fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R., E-mail: romain.coulon@cea.f [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette (France); Normand, S., E-mail: stephane.normand@cea.f [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette (France); Ban, G., E-mail: ban@lpccaen.in2p3.f [ENSICAEN, 6 Boulevard Marechal Juin, F-14050 Caen Cedex 4 (France); Barat, E.; Montagu, T.; Dautremer, T. [CEA, LIST, Laboratoire Modelisation Simulation et Systemes, F-91191 Gif-sur-Yvette (France); Brau, H.-P. [ICSM, Centre de Marcoule, BP 17171 F-30207 Bagnols sur Ceze (France); Dumarcher, V. [AREVA NP, SET, F-84500 Bollene (France); Michel, M.; Barbot, L.; Domenech, T.; Boudergui, K.; Bourbotte, J.-M. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette (France); Jousset, P. [CEA, LIST, Departement des Capteurs, du Signal et de l' Information, F-91191 Gif-sur-Yvette (France); Barouch, G.; Ravaux, S.; Carrel, F. [CEA, LIST, Laboratoire Modelisation Simulation et Systemes, F-91191 Gif-sur-Yvette (France); Saurel, N. [CEA, DAM, Laboratoire Mesure de Dechets et Expertise, F-21120 Is-sur-Tille (France); Frelin-Labalme, A.-M.; Hamrita, H. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette (France)

    2011-01-15

    Graphical abstract: Display Omitted Research highlights: {sup 20}F and {sup 23}Ne tagging agents are produced by fast neutron flux. {sup 20}F signal has been measured at the SFR Phenix prototype. A random error of only 3% for an integration time of 2 s could be achieved. {sup 20}F and {sup 23}Ne power measurement has a reduced temperature influence. Burn-up impact could be limited by simultaneous {sup 20}F and {sup 23}Ne measurement. - Abstract: Previous works on pressurized water reactors show that the nitrogen 16 activation product can be used to measure thermal power. Power monitoring using a more stable indicator than ex-core neutron measurements is required for operational sodium-cooled fast reactors, in order to improve their economic efficiency at the nominal operating point. The fluorine 20 and neon 23 produced by (n,{alpha}) and (n,p) capture in the sodium coolant have this type of convenient characteristic, suitable for power measurements with low build-up effects and a potentially limited temperature, flow rate, burn-up and breeding dependence. This method was tested for the first time during the final tests program of the French Phenix sodium-cooled fast reactor at CEA Marcoule, using the ADONIS gamma pulse analyzer. Despite a non-optimal experimental configuration for this application, the delayed gamma power measurement was pre-validated, and found to provide promising results.

  9. Evaluation of the Initial Isothermal Physics Measurements at the Fast Flux Test Facility, a Prototypic Liquid Metal Fast Breeder Reactor

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess

    2010-03-01

    The Fast Flux Test Facility (FFTF) was a 400-MWt, sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission reactor plant designed for the irradiation testing of nuclear reactor fuels and materials for the development of liquid metal fast breeder reactors (LMFBRs). The FFTF was fueled with plutonium-uranium mixed oxide (MOX) and reflected by Inconel-600. Westinghouse Hanford Company operated the FFTF as part of the Hanford Engineering Development Laboratory (HEDL) for the U.S. Department of Energy on the Hanford Site near Richland, Washington. Although the FFTF was a testing facility not specifically designed to breed fuel or produce electricity, it did provide valuable information for LMFBR projects and base technology programs in the areas of plant system and component design, component fabrication, prototype testing, and site construction. The major objectives of the FFTF were to provide a strong, disciplined engineering base for the LMFBR program, provide fast flux testing for other U.S. programs, and contribute to the development of a viable self-sustaining competitive U.S. LMFBR industry. During its ten years of operation, the FFTF acted as a national research facility to test advanced nuclear fuels, materials, components, systems, nuclear power plant operating and maintenance procedures, and active and passive reactor safety technologies; it also produced a large number of isotopes for medical and industrial users, generated tritium for the U.S. fusion research program, and participated in cooperative, international research work. Prior to the implementation of the reactor characterization program, a series of isothermal physics measurements were performed; this acceptance testing program consisted of a series of control rod worths, critical rod positions, subcriticality measurements, maximum reactivity addition rates, shutdown margins, excess reactivity, and isothermal temperature coefficient reactivity. The results of these

  10. A comparison of fast and reactive pyrolysis with insitu derivatisation of fructose, inulin and Jerusalem artichoke (Helianthus tuberosus).

    Science.gov (United States)

    Mattonai, Marco; Ribechini, Erika

    2018-08-09

    Reactive pyrolysis is a technique that provides mechanistic information by performing pyrolysis of the substrate in a sealed glass capsule at elevated temperature and pressure for relatively long time. This technique has already shown great potential for the analysis of biomass, favouring the formation of only the most thermostable compounds. In this work, both fast and reactive pyrolysis with on-line gas chromatography-mass spectrometry analysis (Py-GC/MS) are used to study fructose, inulin and Jerusalem artichoke tubers (Heliantus tuberosus). Interesting differences were found between the two systems, and became even more evident as the reaction time was increased. The most striking result was the formation of di-fructose dianhydrides (DFAs), a class of compounds with interesting biological activities. DFAs were obtained in high yields from reactive pyrolysis, but not from fast pyrolysis. Hypotheses on the pyrolysis mechanisms were made based upon the composition of the pyrolysates. This work describes for the first time the behaviour of fructans under reactive pyrolysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Characterization and reactivity of soot from fast pyrolysis of lignocellulosic compounds and monolignols

    DEFF Research Database (Denmark)

    Trubetskaya, Anna; Brown, Avery; Tompsett, Geoffrey

    2018-01-01

    This study presents the effect of lignocellulosic compounds and monolignols on the yield, nanostructure and reactivity of soot generated at 1250 °C in a drop tube furnace. The structure of soot was characterized by electron microscopy techniques, Raman spectroscopy and electron spin resonance spe...... of the extraction solvent had a strong influence on the soot reactivity. The Soxhlet extraction of softwood and wheat straw lignin soot using methanol decreased the soot reactivity, whereas acetone extraction had only a modest effect....

  12. Measurement scheme and simulation for the main reflector of FAST

    International Nuclear Information System (INIS)

    Hu, Jinwen; Nan, Rendong; Zhu, Lichun; Li, Xinyi

    2013-01-01

    FAST (five-hundred-meter aperture spherical radio telescope) is a radio telescope being built in a karst depression in Guizhou Province of China, which will be the largest single dish radio telescope in the world [1]. The reflector of the telescope is composed of over 4000 panels, and each panel could adjust its position according to observation requirements. During observations, panels in the illuminated area could form a paraboloid to correct spherical aberration [2]. Therefore, accurate measurement of the positions of panels is crucial for the operation of the telescope. In this paper, we introduce the measurement scheme for the reflector of FAST, and simulate its accuracy using direct linear transform, Gauss–Newton algorithm, Levenberg–Marquardt algorithm and an algorithm referred to as multi-point algorithm. Advantages and disadvantages of using these four methods are compared for analysis at different locations of the panels on the reflector, and suggestions are given in choosing algorithms in implementation. (paper)

  13. Nuclear data sensitivity and uncertainty assessment of sodium voiding reactivity coefficients of an ASTRID-like sodium fast reactor

    Science.gov (United States)

    Nuria, García-Herranz; Anne-Laurène, Panadero; Ana, Martinez; Sandro, Pelloni; Konstantin, Mikityuk; Andreas, Pautz

    2017-09-01

    The EU 7th Framework ESNII+ project was launched in 2013 with the strategic orientation of preparing ESNII for Horizon 2020. ESNII stands for the European Industrial Initiative on Nuclear Energy, created by the European Commission in 2010 to promote the development of a new generation of nuclear systems in order to provide a sustainable solution to cope with Europe's growing energy needs while meeting the greenhouse gas emissions reduction target. The designs selected by the ESNII+ project are technological demonstrators of Generation-IV systems. The prototype for the sodium cooled fast reactor technology is ASTRID (standing for Advanced Sodium Technological Reactor for Industrial Demonstration), which detailed design phase is foreseen to be initiated in 2019. The ASTRID core has a peculiar design which was created in order to tackle the main neutronic challenge of sodium cooled fast reactors: the inherent overall positive reactivity feedback in case of sodium voiding occurring in the core. Indeed, the core is claimed by its designers to have an overall negative reactivity feedback in this scenario. This feature was demonstrated for an ASTRID-like core within the ESNII+ framework studies performed by nine European institutions. In order to shift the paradigm towards best-estimate plus uncertainties, the nuclear data sensitivity analysis and uncertainty propagation on reactivity coefficients has to be carried out. The goal of this work is to assess the impact of nuclear data uncertainties on sodium voiding reactivity feedback coefficients in order to get a more complete picture of the actual safety margins of the ASTRID low void-core design. The nuclear data sensitivity analysis is performed in parallel using SCALE TSUNAMI-3D and the newly developed GPT SERPENT 2 module. A comparison is carried out between the two methodologies. Uncertainty on the sodium reactivity feedbacks is then calculated using TSAR module of SCALE and the necessary safety margins conclusions

  14. Nuclear data sensitivity and uncertainty assessment of sodium voiding reactivity coefficients of an ASTRID-like sodium fast reactor

    Directory of Open Access Journals (Sweden)

    Nuria García-Herranz

    2017-01-01

    Full Text Available The EU 7th Framework ESNII+ project was launched in 2013 with the strategic orientation of preparing ESNII for Horizon 2020. ESNII stands for the European Industrial Initiative on Nuclear Energy, created by the European Commission in 2010 to promote the development of a new generation of nuclear systems in order to provide a sustainable solution to cope with Europe’s growing energy needs while meeting the greenhouse gas emissions reduction target. The designs selected by the ESNII+ project are technological demonstrators of Generation-IV systems. The prototype for the sodium cooled fast reactor technology is ASTRID (standing for Advanced Sodium Technological Reactor for Industrial Demonstration, which detailed design phase is foreseen to be initiated in 2019. The ASTRID core has a peculiar design which was created in order to tackle the main neutronic challenge of sodium cooled fast reactors: the inherent overall positive reactivity feedback in case of sodium voiding occurring in the core. Indeed, the core is claimed by its designers to have an overall negative reactivity feedback in this scenario. This feature was demonstrated for an ASTRID-like core within the ESNII+ framework studies performed by nine European institutions. In order to shift the paradigm towards best-estimate plus uncertainties, the nuclear data sensitivity analysis and uncertainty propagation on reactivity coefficients has to be carried out. The goal of this work is to assess the impact of nuclear data uncertainties on sodium voiding reactivity feedback coefficients in order to get a more complete picture of the actual safety margins of the ASTRID low void-core design. The nuclear data sensitivity analysis is performed in parallel using SCALE TSUNAMI-3D and the newly developed GPT SERPENT 2 module. A comparison is carried out between the two methodologies. Uncertainty on the sodium reactivity feedbacks is then calculated using TSAR module of SCALE and the necessary safety

  15. Fast Plasma Potential Measurements Using an Emissive Probe

    Science.gov (United States)

    Ready, Amanda; Clark, Michael; Endrizzi, Douglass; Forest, Cary; Peterson, Ethan

    2017-10-01

    A heated emissive probe was developed for making direct plasma potential (Vp) measurements in rapidly fluctuating plasmas. Previous experiments on the Big Red Ball (BRB) were hindered by sudden potential drops, making Langmuir measurements of the plasma potential difficult. DC heating of a tungsten filament to emission allowed for fast (4 MHz) floating potential measurements that closely matched Vp. Two BRB experiments currently use the emissive probe. The investigation of unmagnetized, collisionless shocks used plasma potential measurements to study the sub-structure of strong plasma shocks. A separate investigation of emulated magnetospheres in laboratory plasmas used the plasma potential to map the equilibria and instabilities in the electric field of such structures. Results showing electric field measurements and comparison with cold Langmuir measurements will be presented. Future plans for probe modifications and applications to other experiments on the BRB will also be shown.

  16. A negative reactivity feedback driven by induced buoyancy after a temperature transient in lead-cooled fast reactors

    Directory of Open Access Journals (Sweden)

    Francisco J. Arias

    2018-02-01

    Full Text Available Consideration is given to the possibility to use changes in buoyancy as a negative reactivity feedback mechanism during temperature transients in heavy liquid metal fast reactors. It is shown that by the proper use of heavy pellets in the fuel elements, fuel rods could be endowed with a passive self-ejection mechanism and then with a negative feedback. A first estimate of the feasibility of the mechanism is calculated by using a simplified geometry and model. If in addition, a neutron poison pellet is introduced at the bottom of the fuel, then when the fuel element is displaced upward by buoyancy force, the reactivity will be reduced not only by disassembly of the core but also by introducing the neutron poison from the bottom. The use of induced buoyancy opens up the possibility of introducing greater amounts of actinides into the core, as well as providing a palliative solution to the problem of positive coolant temperature reactivity coefficients that could be featured by the heavy liquid metal fast reactors.

  17. Activation measurements for fast neutrons. Part E. Evaluation of fast neutron 63Ni transmission factors

    International Nuclear Information System (INIS)

    Egbert, Stephen D.

    2005-01-01

    The 63 Ni measurements for fast neutrons in copper samples are compared to the calculated free-in-air 63 Ni neutron activation given in Chapter 3 by use of transmission factors. Transmission factors were calculated to account for the modification of the fluence and activation at each sample's in situ location. For the purposes of this discussion, the transmission factor (TF) is defined as the ratio of the in situ sample activation divided by the untilted free-in-air (FIA) activation at a height of 1 m above ground at the same ground range. Examples of the application of TF's will be provided in this section. (author)

  18. Atmospheric measurements of total OH reactivity: Intercomparison of the pump-probe technique and the comparative reactivity method

    Science.gov (United States)

    Dusanter, Sebastien; Hansen, Robert; Leonardis, Thierry; Schoemaecker, Coralie; Blocquet, Marion; Fittschen, Christa; Hanoune, Benjamin; Sinha, Vinayak; Stevens, Philip; Locoge, Nadine

    2013-04-01

    The hydroxyl radical (OH) drives the oxidation of organic trace gases that can lead to the production of ozone and secondary organic aerosols in the atmosphere. A complete understanding of the sources and sinks of OH is therefore important to address issues related to both air quality and climate change. However, recent measurements of total OH reactivity [1-2], which is the inverse of the OH lifetime, have pointed out that our understanding of OH sinks is still incomplete and important reactive trace gases have not yet been identified. These measurements of total OH reactivity are of particular interest since they provide a critical test of our understanding of the OH budget. Three techniques are available to measure the total OH reactivity, including the total OH loss rate method [3], the pump-probe method [4], and the comparative reactivity method (CRM) [5]. While the first two methods are based on direct measurements of OH decays using laser-induced fluorescence instruments, the CRM is based on a different approach in which a tracer molecule is detected instead of OH to determine the ambient OH loss rate. As these instruments were deployed in different field campaigns, intercomparison exercises would be useful to ensure the accuracy of the measurements. However, such intercomparisons have not yet been published. An informal intercomparison involving a CRM instrument from the Ecole des Mines de Douai (EMD) and a pump-probe instrument from the laboratory Physicochimie des Processus de Combustion et de l'Atmosphere (PC2A) took place in an urban environment at the university of Lille (France). The two OH reactivity instruments measured continuously side by side for a duration of two weeks. Collocated measurements of trace gases were also performed using O3, NOx and SO2 monitors, as well as two automated chromatographic instruments capable of measuring more than 50 volatile organic compounds (VOC). We will present cross calibrations of the two OH reactivity

  19. MAGNETIC FIELD MEASUREMENTS FOR FAST-CHANGING MAGNETIC FIELDS

    International Nuclear Information System (INIS)

    2004-01-01

    Several recent applications for fast ramped magnets have been found that require rapid measurement of the field quality during the ramp. (In one instance, accelerator dipoles will be ramped at 1 T/sec, with measurements needed to the accuracy typically required for accelerators.) We have built and tested a new type of magnetic field measuring system to meet this need. The system consists of 16 stationary pickup windings mounted on a cylinder. The signals induced in the windings in a changing magnetic field are sampled and analyzed to obtain the field harmonics. To minimize costs, printed circuit boards were used for the pickup windings and a combination of amplifiers and ADPs used for the voltage readout system. New software was developed for the analysis. Magnetic field measurements of a model dipole developed for the SIS200 accelerator at GSI are presented. The measurements are needed to insure that eddy currents induced by the fast ramps do not impact the field quality needed for successful accelerator operation

  20. Evaluation on Calculation Accuracy of the Sodium Void Reactivity for Low Void Effect Fast Reactor Cores with Experimental Analyses

    International Nuclear Information System (INIS)

    Sugino, K.; Ishikawa, M.; Numata, K.

    2015-01-01

    Calculation accuracy of the sodium void reactivity for safety-enhanced fast reactor core concepts was evaluated with analyses of critical experiments. In these concepts, heterogeneous core configuration and sodium plenum replacement are adopted to reduce the sodium void reactivity to around zero. In the past, a variety of critical experiments for heterogeneous cores had been carried out in the ZPPR facility, some of which are compiled in the IRPhEP handbook. Further, several experiments for core with sodium plenum had been performed in the BFS-2 facility. Calculation analyses of above mentioned critical experiments have been performed by using the Japanese current reactor physics analytical system. These analyses clarified that accuracy for homogeneous and axially-heterogeneous cores was sufficient, though accuracy for the radially-heterogeneous core and/or core with sodium plenum was not satisfactory. In order to achieve satisfactory accuracy for various types of cores, investigation on several design methods was performed. (author)

  1. Monte Carlo transport correction of sodium reactivity worth spatial distribution in perspective Sodium-Cooled Fast Reactor

    International Nuclear Information System (INIS)

    Raskach, K.F.; Blyskavka, V; Kislitsyna, T.S.

    2011-01-01

    In this paper we apply Monte Carlo for calculating spatial distribution of sodium reactivity worth in the perspective Russian sodium-cooled fast reactor BN-1200. A special Monte Carlo technique applicable for calculating perturbations and derivatives of the effective multiplication factor is used. The numerical results obtained show that Monte Carlo has a good perspective to deal with such problems and to be used as a reference solution for engineering codes based on the diffusion approximation. They also allow to conclude that in the sodium blanket and in the neighboring region of the core the diffusion code used likely overestimates sodium reactivity worth. This conclusion has to be verified in future work. (author)

  2. Fast pressure measurements for the TMX-U fusion experiment

    International Nuclear Information System (INIS)

    Hunt, A.L.; Coffield, F.E.; Pickles, W.L.

    1982-01-01

    The pressure on the boundary of the Lawrence Livermore National Laboratory's (LLNL) tandem mirror (TMX-U) plasma experiment is difficult to trace for several reasons: (1) the TMX-U boundary is in the high vacuum range (10 -5 to 10 -6 Pa) and requires an ionization gauge; (2) the boundary includes high-energy neutral particles and radiation, so the gauge must be optically baffled from the plasma; (3) the gauge must be shielded from the magnetic flux density of 0.03 T; (4) maximum conductance to the gauge must be preserved so that the time response remains about 1 ms; (5) a fast electrical circuit is required to measure the small ion-current changes at a rate consistent with the geometrical and experimental time constant of 1 ms. We have developed solutions to these limitations, including fast ionization gauge (FIG) circuitry for the remote gauge operation and the CAMAC system for recording the pressure-time history in the TMX-U computer data base. We also give some examples of actual fast pressure histories during plasma operation

  3. Do GIS-derived measures of fast food retailers convey perceived fast food opportunities? Implications for food environment assessment.

    Science.gov (United States)

    Barnes, Timothy L; Colabianchi, Natalie; Freedman, Darcy A; Bell, Bethany A; Liese, Angela D

    2017-01-01

    Geographic information systems (GISs) have been used to define fast food availability, with higher availability perhaps promoting poorer quality diets. Alternative measures involve perceptions; however, few studies have examined associations between GIS-derived and perceived measures of the food environment. Telephone surveys of 705 participants within an eight-county region in South Carolina were analyzed using logistic regression to examine relationships between geographic presence of and distance to various types of food retailers and perceived fast food availability. The mean distance to the nearest fast food restaurant was 6.1 miles, with 16% of participants having a fast food restaurant within 1 mile of home. The geographic presence of and distance to all food retailer types were significantly associated with perceived availability of fast food in unadjusted models. After adjustment, only the presence of a fast food restaurant or pharmacy was significantly associated with greater odds of higher perceived availability of fast food. Greater odds of lower perceived availability of fast food were observed with the presence of a dollar store and increasing distance to the nearest supermarket or pharmacy. Measures of fast food availability, whether objective or perceived, may not be interchangeable. Researchers should carefully decide on the appropriate measurement tool-GIS-derived or perceived-in food environment studies. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Performance measurements at the fast flux test facility

    International Nuclear Information System (INIS)

    In 1984, Fast Flux Test Facility (FFTF) management recognized the need to develop a measurement system that would quantify the operational performance of the FFTF and the human resources needed to operate it. Driven by declining budgets and the need to safely manage a manpower rampdown at FFTF, an early warning system was developed. Although the initiating event for the early warning system was the need to safely manage a manpower rampdown, many related uses have evolved. The initial desired objective for the FFTF performance measurements was to ensure safety and control of key performance trends. However, the early warning system has provided a more quantitative, supportable basis upon which to make decisions. From this initial narrow focus, efforts in the FFTF plant and supporting organizations are leading to measurement of and, subsequently, improvements in productivity. Pilot projects utilizing statistical process control have started with longer range productivity improvement

  5. Distributed solar radiation fast dynamic measurement for PV cells

    Science.gov (United States)

    Wan, Xuefen; Yang, Yi; Cui, Jian; Du, Xingjing; Zheng, Tao; Sardar, Muhammad Sohail

    2017-10-01

    To study the operating characteristics about PV cells, attention must be given to the dynamic behavior of the solar radiation. The dynamic behaviors of annual, monthly, daily and hourly averages of solar radiation have been studied in detail. But faster dynamic behaviors of solar radiation need more researches. The solar radiation random fluctuations in minute-long or second-long range, which lead to alternating radiation and cool down/warm up PV cell frequently, decrease conversion efficiency. Fast dynamic processes of solar radiation are mainly relevant to stochastic moving of clouds. Even in clear sky condition, the solar irradiations show a certain degree of fast variation. To evaluate operating characteristics of PV cells under fast dynamic irradiation, a solar radiation measuring array (SRMA) based on large active area photodiode, LoRa spread spectrum communication and nanoWatt MCU is proposed. This cross photodiodes structure tracks fast stochastic moving of clouds. To compensate response time of pyranometer and reduce system cost, the terminal nodes with low-cost fast-responded large active area photodiode are placed besides positions of tested PV cells. A central node, consists with pyranometer, large active area photodiode, wind detector and host computer, is placed in the center of the central topologies coordinate to scale temporal envelope of solar irradiation and get calibration information between pyranometer and large active area photodiodes. In our SRMA system, the terminal nodes are designed based on Microchip's nanoWatt XLP PIC16F1947. FDS-100 is adopted for large active area photodiode in terminal nodes and host computer. The output current and voltage of each PV cell are monitored by I/V measurement. AS62-T27/SX1278 LoRa communication modules are used for communicating between terminal nodes and host computer. Because the LoRa LPWAN (Low Power Wide Area Network) specification provides seamless interoperability among Smart Things without the

  6. Measurements and calculation of reactivity in the IEA-R1 nuclear reactor

    International Nuclear Information System (INIS)

    Ferreira, P.S.B.

    1988-01-01

    Techniques and experimentals procedures utilized in the measurement of some nuclear parameters related to reactivity are presented. Measurements of reactivity coefficients, such as void, temperature and power, and control rod worth were made in the IEA-R1 Research Reactor. The techniques used to perform the measurements were: i) stable period (control rod calibration), ii) inverse kinetics (digital reactivity meter), iii) aluminium slab insertion in the fuel element coolant channels (void reactivity), iv) nuclear reactor core temperature changes by means of the changes in the coolant systems of reactor core (isothermal reactivity coefficient) and v) by making perturbation in the core through the control rod motions (power reactivity coefficient and control rod calibration). By using the computer codes HAMMER, HAMMER-TECHNION and CITATION, the experiments realized in the IEA-R1 reactor were simulated. From this simulation, the theoretical reactivity parameters were estimated and compared with the respective experimental results. Furthermore, in the second fuel load of Angra-1 Nuclear Power Station, the IPEN-CNEN/SP digital reactivity - meter were used in the lower power test with the aim to assess the equipment performance. Among several tests, the reacticity-meter were used in parallel with a Westinghouse analogic reativimeter-meter) to measure the heat additiona point, critical boron concentration, control rod calibration, isothermal and moderator reactivity coefficient. These tests, and the results obtained by the digital reactivity-meter are described. The results were compared with those obtained by Westinghouse analogic reactivity meter, showing excellent agreement. (author) [pt

  7. New methodology for assessing reactivity feedbacks and uncertainties in sodium-cooled fast reactors

    International Nuclear Information System (INIS)

    Bouret, C.; Buiron, L.; Rimpault, G.

    2014-01-01

    During the design of different SFR cores considered for the ASTRID reactor prototype, the main neutronic variables of interest are evaluated and then used to simulate transients. The assessment, management and reduction of uncertainties on these neutronic quantities help increase the margins and improve performance while cutting the costs of the concept. This paper aims at highlighting the benefits of using perturbation tools based on transport theory to solve the Boltzmann equation on 3D Hexagonal-Z geometry for the calculation of neutronic parameters, sensitivities and uncertainties for the heterogeneous core design. Moreover, a new methodology is proposed to access uncertainty affecting local reactivity feedback coefficients. This method allows taking into account the correlations between the different local reactivity feedback coefficients used to simulate transients. (authors)

  8. MTR fuel element burn-up measurements by the reactivity method

    International Nuclear Information System (INIS)

    Zuniga, A.; Cuya, T.R.; Ravnik, M.

    2003-01-01

    Fuel element burn-up was measured by the reactivity method in the 10 MW Peruvian MTR reactor RP-10. The main purpose of the experiment was testing the reactivity method for an MTR reactor as the reactivity method was originally developed for TRIGA reactors. The reactivity worth of each measured fuel element was measured in its original core position in order to measure the burn-up of the fuel elements that were part of the experimental core. The burn-up of each measured fuel element was derived by interpolating its reactivity worth from the reactivity worth of two reference fuel elements of known burn-up, whose reactivity worth was measured in the position of the measured fuel element. The accuracy of the method was improved by separating the reactivity effect of burn-up from the effect of the position in the core. The results of the experiment showed that the modified reactivity method for fuel element burn-up determination could be applied also to MTR reactors. (orig.)

  9. Synthesis and characterization of high wash fastness novel azo reactive dyes incorporating aromatic bridged diamines

    OpenAIRE

    Aamer Saeed; Ghulam Shabir

    2018-01-01

    A new series of azo reactive dyes containing free chlorine atoms have been synthesized. The synthetic methodology involves the diazotization of 4′4-diamino diphenylamine-2-sulfonic acid (2) followed by azo coupling with 1-amino-8-naphthol-3,6-disulfonic acid (3) in alkaline medium to yield intermediate dye (4). Condensation of the latter with 1,3,5-trichlorotriazine afforded the cyanurated dye (5). A number of novel bis aromatic diamines (1a–j) were separately synthesized as bridging groups a...

  10. Dynamics of fast ions during sawtooth oscillations in the TEXTOR tokamak measured by collective Thomson scattering

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Salewski, Mirko; Bindslev, Henrik

    2011-01-01

    Experimental investigations of sawteeth interaction with fast ions measured by collective Thomson scattering on TEXTOR are presented. Time-resolved measurements of localized 1D fast-ion distribution functions allow us to study fast-ion dynamics during several sawtooth cycles. Sawtooth oscillation...

  11. A measurement of the response to fast neutrons of several materials dosemeters

    International Nuclear Information System (INIS)

    Jones, L.T.; Kitching, S.J.; Lewis, T.A.; Playle, T.S.

    1986-07-01

    The response to fast neutrons was measured for three types of materials testing dosemeters: fast neutron dosimetry silicon diodes; beryllia, alumina and calcium fluoride TLDs; graphite walled ionisation chambers. The calibrations were made using a 3MW positive ion accelerator. The arrangement of the target, beam monitor and devices is described, and the measured fast neutron sensitivities are presented. (UK)

  12. An assessment of methods of calculating sodium voiding reactivity in plutonium fuelled fast reactors

    International Nuclear Information System (INIS)

    Butland, A.T.D.; Simmons, W.N.; Stevenson, J.M.

    1979-01-01

    After a survey of the requirements an assessment of the accuracy of calculations of the sodium void effect using UK methods and data is made on the basis of the following work. First, the analysis of small and large sodium voids in the MOZART and Zebra 13 small (300 MW(E)) fast reactor mock-ups and the BIZET large fast reactor mock-ups, all of conventional design. The analysis was carried out using the UK FGL5 fine group nuclear data library, the MURAL cell code, whole reactor diffusion theory calculations of the neutron flux and perturbation theory methods. Exact perturbation theory was used in many cases, otherwise first order perturbation theory calculations were adjusted to give results equivalent to exact perturbation theory. Second, theoretical studies of some effects, including, the effects of extrapolating to fuel operating temperatures, fuel cycle and burn-up effects, and the heterogeneity effects of large fuelled subassemblies in pin geometry. Third, theoretical studies of approximations in the calculational methods including, the importance in the whole reactor calculation of the energy group structure and the spatial mesh, the importance of reactor material boundaries in the calculation of resonance shielding effects, and the use of neutron fluxes calculated using neutron diffusion theory rather than transport theory. (U.K.)

  13. Fast-food intake and perceived and objective measures of the local fast-food environment in adolescents

    DEFF Research Database (Denmark)

    Svastisalee, Chalida; Pagh Pedersen, Trine; Schipperijn, Jasper

    2016-01-01

    OBJECTIVE: We examined associations between fast-food intake and perceived and objective fast-food outlet exposure. DESIGN: Information from the Health Behaviours in School-aged Children Study was linked to fast-food outlets in seventy-five school neighbourhoods. We used multivariate multilevel...... logistic regression analyses to examine associations between at least weekly fast-food intake and perceived and objective fast-food outlet measures. SUBJECTS: Data represent 4642 adolescents (aged 11-15 years) in Denmark. RESULTS: Boys reporting two or more fast-food outlets had 34 % higher odds consuming...... fast food at least weekly. We detected higher odds of at least weekly fast-food intake among 15-year-old 9th graders (ORall=1·74; 95 % CI 1·40, 2·18; ORboys=2·20; 95 % CI 1·66, 2·91; ORgirls=1·41; 95 % CI 1·03, 1·92), Danish speakers (ORall=2·32; 95 % CI 1·68, 3·19; ORboys=2·58; 95 % CI 1·69, 3...

  14. FAST

    DEFF Research Database (Denmark)

    Zuidmeer-Jongejan, Laurian; Fernandez-Rivas, Montserrat; Poulsen, Lars K.

    2012-01-01

    ABSTRACT: The FAST project (Food Allergy Specific Immunotherapy) aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT), using subcutaneous injections...... with aqueous food extracts may be effective but has proven to be accompanied by too many anaphylactic side-effects. FAST aims to develop a safe alternative by replacing food extracts with hypoallergenic recombinant major allergens as the active ingredients of SIT. Both severe fish and peach allergy are caused...... in depth serological and cellular immune analyses will be performed, allowing identification of novel biomarkers for monitoring treatment efficacy. FAST aims at improving the quality of life of food allergic patients by providing a safe and effective treatment that will significantly lower their threshold...

  15. Investigation on the fast co-pyrolysis of sewage sludge with biomass and the combustion reactivity of residual char.

    Science.gov (United States)

    Deng, Shuanghui; Tan, Houzhang; Wang, Xuebin; Yang, Fuxin; Cao, Ruijie; Wang, Zhao; Ruan, Renhui

    2017-09-01

    Gaining the valuable fuels from sewage sludge is a promising method. In this work, the fast pyrolysis characteristics of sewage sludge (SS), wheat straw (WS) and their mixtures in different proportions were carried out in a drop-tube reactor. The combustion reactivity of the residual char obtained was investigated in a thermogravimetric analyzer (TGA). Results indicate that SS and WS at different pyrolysis temperatures yielded different characteristic gas compositions and product distributions. The co-pyrolysis of SS with WS showed that there existed a synergistic effect in terms of higher gas and bio-oil yields and lower char yield, especially at the WS adding percentage of 80wt%. The addition of WS to SS increased the carbon content in the SS char and improved char porous structures, resulting in an improvement in the combustion reactivity of the SS char. The research results can be used to promote co-utilization of sewage sludge and biomass. Copyright © 2017. Published by Elsevier Ltd.

  16. Generation IV sodium fast reactor. Feedback reactivity coefficients to optimise safe natural core behaviour during accident transients

    International Nuclear Information System (INIS)

    Zaetta, Alain; Bernardin, Bruno; Vanier, Marc; Tommasi, Jean; Varaine, Frederic

    2009-01-01

    One of the key research goals for Generation IV Sodium-cooled Fast Reactors (SFR) is to improve their safety levels, particularly by ensuring robust core behaviour during accident conditions. A dedicated approach called COCONS has been developed to reach these objectives. This paper discusses this approach which focuses on the design of naturally safe core. It can be broken down into three stages: The first stage involves defining the role of feedback reactivity coefficients applicable during accident transients, such as unprotected reactivity insertion transients (UTOP) or unprotected loss-of-cooling-flow transients (ULOF). The parametric study has revealed the impact of the Doppler effect on UTOP and sodium temperature coefficient which is directly related to the sodium void effect for ULOF. The second stage is to define optimised ranges for these reactivity coefficients to avoid any core damage by fuel meltdown or sodium boiling. Conclusions differ greatly depending on the fuel type, e.g. oxide, metal or carbide. Fuel temperature margins before fuel meltdown and average fuel temperatures play a very important role. The third stage involves recommending several core concepts that are capable of achieving these idealistic ranges. Several new oxide fuel subassembly designs are suggested in view of reducing the maximum fuel temperature and increasing margins to fuel meltdown. Ceramic carbide fuel seems to be a very promising choice from a reactor physics viewpoint. Combined with moderator material in the core or used with the new fuel 'plate' subassembly concept, ceramic carbide fuel seems capable of achieving safe natural behaviour during either a UTOP or ULOF transient. The COCONS approach appears to be a useful tool in terms of recommending new SFR core options and comparing overall performance levels with reactor safety levels. Final optimization will require more general comparisons, taking into account all the main Generation IV goals i.e. economic

  17. Measured and evaluated fast neutron cross sections of elemental nickel

    International Nuclear Information System (INIS)

    Guenther, P.; Smith, A.; Smith, D.; Whalen, J.; Howerton, R.

    1975-07-01

    Fast neutron total and scattering cross sections of elemental nickel are measured. Differential elastic scattering cross sections are determined from incident energies of 0.3 to 4.0 MeV. The cross sections for the inelastic neutron excitation of states at: 1.156 +- 0.015, 1.324 +- 0.015, 1.443 +- 0.015, 2.136 +- 0.013, 2.255 +- 0.030, 2.449 +- 0.030, 2.614 +- 0.020 and 2.791 +- 0.025 MeV are measured to incident neutron energies of 4.0 MeV. The total neutron cross sections are determined from 0.25 to 5.0 MeV. The experimental results are discussed in the context of optical and statistical models. It is shown that resonance width-fluctuation and correlation effects are significant. The present experimental and theoretical results, together with previously reported values, are used to construct a comprehensive evaluated elemental data file in the ENDF format. Some comparisons are made with previously reported evaluated files. In addition, some selected reactions which are widely used in dosimetry and other applications are presented as supplemental evaluated isotopic-data files. The numerical quantities are presented in tabular form. (3 tables, 29 figures)

  18. An assessment of methods of calculating sodium-voiding reactivity in plutonium-fuelled fast reactors

    International Nuclear Information System (INIS)

    Butland, A.T.D.; Simmons, W.N.; Stevenson, J.M.

    1980-01-01

    After a survey of the requirements an assessment of the accuracy of calculations of the sodium-void effect using UK methods and data is made on the basis of the following work: (a) The analysis of small and large sodium voids in the MOZART and Zebra 13 small (300 MW(e)) fast reactor mock-ups and the BIZET large fast reactor mock-ups, all of conventional design. The analysis was carried out using the UK FGL5 fine group nuclear data library, the MURAL cell code, whole reactor diffusion theory calculations of the neutron flux and perturbation theory methods. Exact perturbation theory was used in many cases, otherwise first-order perturbation theory calculations were adjusted to give results equivalent to exact perturbation theory. (b) Theoretical studies of some effects, including the following: (i) The effects of extrapolating to fuel operating temperature; (ii) Fuel-cycle and burnup effects, including the gradual replacement through a fuel cycle of control-rod absorption by fission product absorption, the loss of fissile material and the change in fuel nuclide relative composition; (iii) The heterogeneity effects of large fuelled subassemblies in pin geometry. (c) Theoretical studies of approximations in the calculational methods, including the following: (i) The importance in the whole reactor calculation of the energy group structure and the spatial mesh, including comparisons of calculations in two (RZ) and three-dimensional geometry; (ii) The importance of reactor material boundaries in the calculation of resonance shielding effects; (iii) The use of neutron fluxes calculated using neutron diffusion theory rather than transport theory. (author)

  19. Fast, automated measurement of nematode swimming (thrashing without morphometry

    Directory of Open Access Journals (Sweden)

    Sattelle David B

    2009-07-01

    less than 30 s and can therefore be deployed in rapid screens. Conclusion We demonstrate that a covariance-based method yields a fast, reliable, automated measurement of C. elegans motility which can replace the far more time-consuming, manual method. The absence of a morphometry step means that the method can be applied to any nematode that swims in liquid and, together with its speed, this simplicity lends itself to deployment in large-scale chemical and genetic screens.

  20. FAST

    Science.gov (United States)

    Nathavitharana, R R; Daru, P; Barrera, A E; Mostofa Kamal, S M; Islam, S; Ul-Alam, M; Sultana, R; Rahman, M; Hossain, Md S; Lederer, P; Hurwitz, S; Chakraborty, K; Kak, N; Tierney, D B; Nardell, E

    2017-09-01

    National Institute of Diseases of the Chest and Hospital, Dhaka; Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorders, Dhaka; and Chittagong Chest Disease Hospital, Chittagong, Bangladesh. To present operational data and discuss the challenges of implementing FAST (Find cases Actively, Separate safely and Treat effectively) as a tuberculosis (TB) transmission control strategy. FAST was implemented sequentially at three hospitals. Using Xpert® MTB/RIF, 733/6028 (12.2%, 95%CI 11.4-13.0) patients were diagnosed with unsuspected TB. Patients with a history of TB who were admitted with other lung diseases had more than twice the odds of being diagnosed with unsuspected TB as those with no history of TB (OR 2.6, 95%CI 2.2-3.0, P stakeholder engagement and laboratory capacity are important for sustainability and scalability.

  1. Detailed characterization of a Comparative Reactivity Method (CRM) instrument for ambient OH reactivity measurements: experiments vs. modeling

    Science.gov (United States)

    Michoud, Vincent; Locoge, Nadine; Dusanter, Sébastien

    2015-04-01

    The Hydroxyl radical (OH) is the main daytime oxidant in the troposphere, leading to the oxidation of Volatile Organic Compounds (VOCs) and the formation of harmful pollutants such as ozone (O3) and Secondary Organic Aerosols (SOA). While OH plays a key role in tropospheric chemistry, recent studies have highlighted that there are still uncertainties associated with the OH budget, i.e the identification of sources and sinks and the quantification of production and loss rates of this radical. It has been demonstrated that ambient measurements of the total OH loss rate (also called total OH reactivity) can be used to identify and reduce these uncertainties. In this context, the Comparative Reactivity Method (CRM), developed by Sinha et al. (ACP, 2008), is a promising technique to measure total OH reactivity in ambient air and has already been used during several field campaigns. This technique relies on monitoring competitive reactions of OH with ambient trace gases and a reference compound (pyrrole) in a sampling reactor to derive ambient OH reactivity. However, this technique requires a complex data processing chain that has yet to be carefully investigated in the laboratory. In this study, we present a detailed characterization of a CRM instrument developed at Mines Douai, France. Experiments have been performed to investigate the dependence of the CRM response on humidity, ambient NOx levels, and the pyrrole-to-OH ratio inside the sampling reactor. Box modelling of the chemistry occurring in the reactor has also been performed to assess our theoretical understanding of the CRM measurement. This work shows that the CRM response is sensitive to both humidity and NOx, which can be accounted for during data processing using parameterizations depending on the pyrrole-to-OH ratio. The agreement observed between laboratory studies and model results suggests a good understanding of the chemistry occurring in the sampling reactor and gives confidence in the CRM

  2. Methods to determine fast-ion distribution functions from multi-diagnostic measurements

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko

    Understanding the behaviour of fast ions in a fusion plasma is very important, since the fusion-born alpha particles are expected to be the main source of heating in a fusion power plant. Preferably, the entire fast-ion velocity-space distribution function would be measured. However, no fast-ion ...

  3. Method of measuring reactive acoustic power density in a fluid

    Science.gov (United States)

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1985-09-03

    A method for determining reactive acoustic power density level and its direction in a fluid using a single sensor is disclosed. In the preferred embodiment, an apparatus for conducting the method, which is termed a thermoacoustic couple, consists of a stack of thin, spaced apart polymeric plates, selected ones of which include multiple bimetallic thermocouple junctions positioned along opposite end edges thereof. The thermocouple junctions are connected in series in the nature of a thermopile, and are arranged so as to be responsive to small temperature differences between the opposite edges of the plates. The magnitude of the temperature difference, as represented by the magnitude of the electrical potential difference generated by the thermopile, is found to be directly related to the level of acoustic power density in the gas. 5 figs.

  4. Cerebrovascular reactivity in migraineurs as measured by transcranial Doppler

    International Nuclear Information System (INIS)

    Thomas, T.D.; Harpold, G.J.

    1990-01-01

    Transcranial Doppler ultrasound is a relatively new diagnostic modality which allows the non-invasive assessment of intracranial circulation. A total of 10 migraine patients were studied and compared to healthy controls without headaches. Migraineurs during the headache-free interval demonstrated excessive cerebrovascular reactivity to CO 2 , evidenced by an increase in middle cerebral artery blood flow velocity of 47% ± 15% compared to 28% ± 14% in controls. Differences between the two study groups revealed no significant decrease in middle cerebral artery blood flow velocity with hypocapnia. However, the differences between middle cerebral artery blood flow velocity during hyperventilation and CO 2 inhalation were significantly different comparing migraineurs and controls. Instability of the baseline blood flow velocities was also noted in migraineurs during the interictal period. Characteristics which may allow differentiation of migraineurs from other headache populations could possibly be obtained from transcranial Doppler ultrasound flow studies. 24 refs., 2 tabs

  5. Direct measurement of NO3 radical reactivity in a boreal forest

    Science.gov (United States)

    Liebmann, Jonathan; Karu, Einar; Sobanski, Nicolas; Schuladen, Jan; Ehn, Mikael; Schallhart, Simon; Quéléver, Lauriane; Hellen, Heidi; Hakola, Hannele; Hoffmann, Thorsten; Williams, Jonathan; Fischer, Horst; Lelieveld, Jos; Crowley, John N.

    2018-03-01

    We present the first direct measurements of NO3 reactivity (or inverse lifetime, s-1) in the Finnish boreal forest. The data were obtained during the IBAIRN campaign (Influence of Biosphere-Atmosphere Interactions on the Reactive Nitrogen budget) which took place in Hyytiälä, Finland during the summer/autumn transition in September 2016. The NO3 reactivity was generally very high with a maximum value of 0.94 s-1 and displayed a strong diel variation with a campaign-averaged nighttime mean value of 0.11 s-1 compared to a daytime value of 0.04 s-1. The highest nighttime NO3 reactivity was accompanied by major depletion of canopy level ozone and was associated with strong temperature inversions and high levels of monoterpenes. The daytime reactivity was sufficiently large that reactions of NO3 with organic trace gases could compete with photolysis and reaction with NO. There was no significant reduction in the measured NO3 reactivity between the beginning and end of the campaign, indicating that any seasonal reduction in canopy emissions of reactive biogenic trace gases was offset by emissions from the forest floor. Observations of biogenic hydrocarbons (BVOCs) suggested a dominant role for monoterpenes in determining the NO3 reactivity. Reactivity not accounted for by in situ measurement of NO and BVOCs was variable across the diel cycle with, on average, ≈ 30 % missing during nighttime and ≈ 60 % missing during the day. Measurement of the NO3 reactivity at various heights (8.5 to 25 m) both above and below the canopy, revealed a strong nighttime, vertical gradient with maximum values closest to the ground. The gradient disappeared during the daytime due to efficient vertical mixing.

  6. Experimental Development and Demonstration of Ultrasonic Measurement Diagnostics for Sodium Fast Reactor Thermal-hydraulics

    Energy Technology Data Exchange (ETDEWEB)

    Tokuhiro, Akira; Jones, Byron

    2013-09-13

    This research project will address some of the principal technology issues related to sodium-cooled fast reactors (SFR), primarily the development and demonstration of ultrasonic measurement diagnostics linked to effective thermal convective sensing under normatl and off-normal conditions. Sodium is well-suited as a heat transfer medium for the SFR. However, because it is chemically reactive and optically opaque, it presents engineering accessibility constraints relative to operations and maintenance (O&M) and in-service inspection (ISI) technologies that are currently used for light water reactors. Thus, there are limited sensing options for conducting thermohydraulic measurements under normal conditions and off-normal events (maintenance, unanticipated events). Acoustic methods, primarily ultrasonics, are a key measurement technology with applications in non-destructive testing, component imaging, thermometry, and velocimetry. THis project would have yielded a better quantitative and qualitative understanding of the thermohydraulic condition of solium under varied flow conditions. THe scope of work will evaluate and demonstrate ultrasonic technologies and define instrumentation options for the SFR.

  7. Evidence of fast non-linear feedback in EBR-II rod-drop measurements

    International Nuclear Information System (INIS)

    Grimm, K.N.; Meneghetti, D.

    1987-06-01

    Feedback reactivities determine the time dependence of a reactor during and after a transient initiating event. Recent analysis of control-rod drops in the Experimental Breeder Reactor II (EBR-II) Reactor has indicated that some relatively fast feedback may exist which cannot be accounted for by the linear feedback mechanisms. The linear and deduced non-linear feedback reactivities from a control-rod drop in EBR-II run 93A using detailed temperature coefficients of reactivity in the EROS kinetics code have been reported. The transient analyses have now been examined in more detail for times close to the drop to ascertain if additional positive reactivity is being built-in early in the drop which could be gradually released later in the drop

  8. Fast-food intake and perceived and objective measures of the local fast-food environment in adolescents.

    Science.gov (United States)

    Svastisalee, Chalida; Pagh Pedersen, Trine; Schipperijn, Jasper; Jørgensen, Sanne Ellegaard; Holstein, Bjørn E; Krølner, Rikke

    2016-02-01

    We examined associations between fast-food intake and perceived and objective fast-food outlet exposure. Information from the Health Behaviours in School-aged Children Study was linked to fast-food outlets in seventy-five school neighbourhoods. We used multivariate multilevel logistic regression analyses to examine associations between at least weekly fast-food intake and perceived and objective fast-food outlet measures. Data represent 4642 adolescents (aged 11-15 years) in Denmark. Boys reporting two or more fast-food outlets had 34% higher odds consuming fast food at least weekly. We detected higher odds of at least weekly fast-food intake among 15-year-old 9th graders (ORall=1.74; 95% CI 1.40, 2.18; ORboys=2.20; 95% CI 1.66, 2.91; ORgirls=1.41; 95% CI 1.03, 1.92), Danish speakers (ORall=2.32; 95% CI 1.68, 3.19; ORboys=2.58; 95% CI 1.69, 3.93; ORgirls=2.37; 95% CI 1.46, 3.84) and those travelling 15 min or less to school (ORall=1.21; 95% CI 1.00, 1.46; ORgirls=1.44; 95% CI 1.08, 1.93) compared with 11-year-old 5th graders, non-Danish speakers and those with longer travel times. Boys from middle- (OR=1.28; 95% CI 1.00, 1.65) and girls from low-income families (OR=1.46; 95% CI 1.05, 2.04) had higher odds of at least weekly fast-food intake compared with those from high-income backgrounds. Girls attending schools with canteens (OR=1.47; 95% CI 1.00, 2.15) had higher odds of at least weekly fast-food intake than girls at schools without canteens. The present study demonstrates that perceived food outlets may impact fast-food intake in boys while proximity impacts intake in girls. Public health planning could target food environments that emphasize a better understanding of how adolescents use local resources.

  9. Detailed neutronic study of the power evolution for the European Sodium Fast Reactor during a positive insertion of reactivity

    Energy Technology Data Exchange (ETDEWEB)

    Facchini, A.; Giusti, V.; Ciolini, R. [Department of Civil and Industrial Engineering (DICI), University of Pisa, Largo Lucio Lazzarino 2, I-56126 Pisa (Italy); Tuček, K.; Thomas, D. [Joint Research Centre, Institute for Energy and Transport (JRC - IET), European Commission, P.O. Box 2, NL-1755 ZG Petten (Netherlands); D' Agata, E., E-mail: elio.dagata@ec.europa.eu [Joint Research Centre, Institute for Energy and Transport (JRC - IET), European Commission, P.O. Box 2, NL-1755 ZG Petten (Netherlands)

    2017-03-15

    Highlights: • This paper studies the effect of an unexpected runway of a control rod in the ESFR. • The power peaked fuel pin within the core was identified. • The increase of the fission power density of the fuel pin has been evaluated. • Radial/axial fission power density of the power peaked fuel pin has been evaluated. - Abstract: The new reactor concepts proposed in the Generation IV International Forum require the development and validation of new components and new materials. Inside the Collaborative Project on the European Sodium Fast Reactor, several accidental scenario have been studied. Nevertheless, none of them coped with mechanical safety assessment of the fuel cladding under accidental conditions. Among the accidental conditions considered, there is the unprotected transient of overpower (UTOP), due to the insertion, at the end of the first fuel cycle, of a positive reactivity into the reactor core as a consequence of the unexpected runaway of one control rod. The goal of the study was the search for a detailed distribution of the fission power, in the radial and axial directions, within the power peaked fuel pin under the above accidental conditions. Results show that after the control rod ejection an increase from 658 W/cm{sup 3} to 894 W/cm{sup 3}, i.e. of some 36%, is expected for the power peaked fuel pin. This information will represent the base to investigate, in a future work, the fuel cladding safety margin.

  10. Impact of nuclear data uncertainties on the reactivity of an AN ASTRID-like sodium fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Martínez, A.; García-Herranz, N.; Romojaro, P.; Alvarez-Velarde, F.; López, D.

    2015-07-01

    The EU 7 th Framework Project ESNII+ was launched in 2013 in support of the initiative ESNII (European Sustainable Nuclear Industrial Initiative) whose purpose is to design, license, construct and begin the operation of the Sodium Fast Reactor Prototype, ASTRID, before 2025. An ASTRID-like core design has been analyzed (see other paper in this conference) and it was found to have a global negative reactivity feedback to sodium voiding. Taking into account the importance of feedback coefficients on core safety, the influence of the uncertainties in nuclear data should be assessed to have an exhaustive picture of the actual safety margins of ASTRID design. The objective of this work is to contribute to the improvement of the safety of ASTRID nuclear design by assessing different uncertainty propagation methodologies of the TSUNAMI-3D module of the SCALE system [ 1 ]. In this work, TSUNAMI-3D is applied to a pin-cell of the inner zone of the ASTRID core in order to select the optimal TSUNAMI-3D parameters. These parameters will be applied in future works to the Sensitivity and Uncertainty (S/U) analysis of the full core. (Author)

  11. Hot gas flow cell for optical measurements on reactive gases

    DEFF Research Database (Denmark)

    Grosch, Helge; Fateev, Alexander; Nielsen, Karsten Lindorff

    2013-01-01

    was validated for high resolution measurements at temperatures of up to 800 K (527 degrees C) in the ultraviolet (UV) and infrared (IR) regions (190-20 000 nm). Verification of the gas temperature in the cell is provided by a thermocouple and emission/transmission measurements in the IR and UV regions. High......-resolution measurements are presented for the absorption cross-section of sulfur dioxide (SO2) in the UV range up to 773 K (500 degrees C)...

  12. Fast optical measurements and imaging of flow mixing

    DEFF Research Database (Denmark)

    Clausen, Sønnik; Fateev, Alexander; Nielsen, Karsten Lindorff

    in combustion enhancement can be also obtained. The infrared camera was also used together with special endoscope optics for fast thermal imaging of a coal-straw flame in an industrial boiler. Obtained time-resolved infrared images provided useful information for the diagnostics of the flame and fuel...

  13. Fast and precise luminosity measurement at the international linear ...

    Indian Academy of Sciences (India)

    The fast investigation of the collision quality for intrabunch feedback and the determination of beam parameters. BeamCal will be hit by a large amount of pairs from ... can be achieved, while preserving 98% of the signal. A harder definition of the cuts can improve the signal-to-background. Pramana – J. Phys., Vol. 69, No.

  14. Reactive Agility Performance in Handball; Development and Evaluation of a Sport-Specific Measurement Protocol.

    Science.gov (United States)

    Spasic, Miodrag; Krolo, Ante; Zenic, Natasa; Delextrat, Anne; Sekulic, Damir

    2015-09-01

    There is no current study that examined sport-specific tests of reactive-agility and change-of-direction-speed (CODS) to replicate real-sport environment in handball (team-handball). This investigation evaluated the reliability and validity of two novel tests designed to assess reactive-agility and CODS of handball players. Participants were female (25.14 ± 3.71 years of age; 1.77 ± 0.09 m and 74.1 ± 6.1 kg) and male handball players (26.9 ± 4.1 years of age; 1.90 ± 0.09 m and 93.90±4.6 kg). Variables included body height, body mass, body mass index, broad jump, 5-m sprint, CODS and reactive-agility tests. Results showed satisfactory reliability for reactive-agility-test and CODS-test (ICC of 0.85-0.93, and CV of 2.4-4.8%). The reactive-agility and CODS shared less than 20% of the common variance. The calculated index of perceptual and reactive capacity (P&RC; ratio between reactive-agility- and CODS-performance) is found to be valid measure in defining true-game reactive-agility performance in handball in both genders. Therefore, the handball athletes' P&RC should be used in the evaluation of real-game reactive-agility performance. Future studies should explore other sport-specific reactive-agility tests and factors associated to such performance in sports involving agile maneuvers. Key pointsReactive agility and change-of-direction-speed should be observed as independent qualities, even when tested over the same course and similar movement templateThe reactive-agility-performance of the handball athletes involved in defensive duties is closer to their non-reactive-agility-score than in their peers who are not involved in defensive dutiesThe handball specific "true-game" reactive-agility-performance should be evaluated as the ratio between reactive-agility and corresponding CODS performance.

  15. Fast optical measurements and imaging of flow mixing: Fast optical measurements and imaging of temperature in combined fossil fuel and biomass/waste systems

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, Soennik; Fateev, A.; Lindorff Nielsen, K.; Evseev, V.

    2012-02-15

    Project is focused on fast time-resolved infrared measurements of gas temperature and fast IR-imagining of flames in various combustion environments. The infrared spectrometer system was developed in the project for fast infrared spectral measurements on industrial scale using IR-fibre- optics. Fast time-and spectral-resolved measurements in 1.5-5.1 mu spectral range give information about flame characteristics like gas and particle temperatures, eddies and turbulent gas mixing. Time-resolved gas composition in that spectral range (H{sub 2}O, CH{sub 4}, CO{sub 2}, CO) which is one of the key parameters in combustion enhancement can be also obtained. The infrared camera was also used together with special endoscope optics for fast thermal imaging of a coal-straw flame in an industrial boiler. Obtained time-resolved infrared images provided useful information for the diagnostics of the flame and fuel distribustion. The applicability of the system for gas leak detection is also demonstrated. The infrared spectrometer system with minor developments was applied for fast time-resolved exhaust gas temperature measurements performed simultaneously at the three optical ports of the exhaust duct of a marine Diesel engine and visualisation of gas flow behaviour in cylinder. (Author)

  16. Reactivity change measurements on plutonium-uranium fuel elements in hector experimental techniques and results

    International Nuclear Information System (INIS)

    Tattersall, R.B.; Small, V.G.; MacBean, I.J.; Howe, W.D.

    1964-08-01

    The techniques used in making reactivity change measurements on HECTOR are described and discussed. Pile period measurements were used in the majority of oases, though the pile oscillator technique was used occasionally. These two methods are compared. Flux determinations were made in the vicinity of the fuel element samples using manganese foils, and the techniques used are described and an error assessment made. Results of both reactivity change and flux measurements on 1.2 in. diameter uranium and plutonium-uranium alloy fuel elements are presented, these measurements being carried out in a variety of graphite moderated lattices at temperatures up to 450 deg. C. (author)

  17. Fast temperature fluctuation measurements in SOL of tokamak TCV

    DEFF Research Database (Denmark)

    Horacek, J.; Nielsen, Anders Henry; Pitts, R.A.

    to compare the statistical character of turbulence in the SOL particle flux on TCV with results from the 2D fluid electrostatic model ESEL [2][4]. Using results from the fast sweeping, similar comparisons can now be made with the fluctuating Te and will be described in this contribution. We also present...... basic statistics derived from the Te time series obtained at different radii in the SOL plasma and show, in particular, that the relationship between higher moments of the probability distribution function from both experimental and simulated Te’s may be well described by the Beta probability...... distribution function, introduced for SOL turbulence in [5]. The fast Te capability also allows the SOL response to Edge Localised Modes (ELMs) to be studied and new results will be presented for the far SOL Te response during Type III ELMs....

  18. A fast gauge for energy flux density measurement

    Science.gov (United States)

    Garcia, Jorge; Bana de Schor, Beatriz

    1990-01-01

    Herein, the design and characterization of a fast energy flux density gauge are described. The gauge is based on a thermoelectrical pair with the junction made of a thin layer of silver. High absorptivity is attained by an electrolytic deposit of platinum black on the silver coat. Dynamic calibration gives a response time below 100 microsec. Computer methods to obtain the energy flux density from temperature-time history were evaluated. The results of the tests performed with igniters of pelleted boron/potassium nitrate and black powder, used in solid propellant ignition, are shown. The gauge developed can be applied to fast processes which require small response time. The gauge does not need previous calibration, it is resistant to vibrations and accelerations, and, at the same time, it is small in size, economical, and easy to build.

  19. OH Reactivity and Potential SOA Yields from Volatile Organic Compounds and Other Trace Gases Measured in Controlled Laboratory Biomass Burns

    Science.gov (United States)

    Gilman, J. B.; Warneke, C.; Kuster, W. C.; Goldan, P. D.; Veres, P. R.; Roberts, J. M.; de Gouw, J. A.; Burling, I. R.; Yokelson, R. J.

    2010-12-01

    A comprehensive suite of instruments were used to characterize volatile organic compounds (VOCs) and other trace gases (e.g., CO, CH4, NO2, etc.) emitted from controlled burns of various fuel types common to the Southeastern and Southwestern United States. These laboratory-based measurements were conducted in February 2009 at the U.S. Department of Agriculture’s Fire Sciences Laboratory in Missoula, Montana. An on-line GC-MS provided highly speciated VOC measurements of alkenes, alkanes, oxygenates, aromatics, biogenics, and nitrogen-containing compounds during the flaming or smoldering phases of replicate burns. The speciated GC-MS “grab” samples were integrated with fast-response gas-phase measurements (e.g., PTR-MS, PTR-IT-MS, NI-PT-CIMS, and FTIR) in order to determine VOC emission ratios and the fraction of identified vs. unidentifiable mass detected by PTR-MS. Emission ratios were used to calculate OH reactivity, which is a measure of potential ozone formation, as well as potential secondary organic aerosol (SOA) yields from the various fuel types. Small oxygenated VOCs had the highest emission ratios of the compounds observed. Alkenes dominated the VOC OH reactivity, which occasionally exceeded 1000 s-1. Calculated SOA yields from known precursors were dominated by aromatic VOCs, such as toluene, naphthalene (C10H8), and 1,3-benzenediol (C6H6O2, resorcinol). The contribution of several compounds not typically reported in ambient air measurements, such as substituted furans (C4H4O), pyrroles (C4H5N), and unsaturated C9 aromatics (C9H10), on OH reactivity and SOA yields will be discussed.

  20. Tunable PIE and synchronized gating detections by FastFLIM for quantitative microscopy measurements of fast dynamics of single molecules

    Science.gov (United States)

    Sun, Yuansheng; Coskun, Ulas; Ferreon, Allan Chris; Barbieri, Beniamino; Liao, Shih-Chu Jeff

    2016-03-01

    The crosstalk between two fluorescent species causes problems in fluorescence microscopy imaging, especially for quantitative measurements such as co-localization, Förster resonance energy transfer (FRET), fluorescence cross correlation spectroscopy (FCCS). In laser scanning confocal microscopy, the lasers can be switched on and off by acousto-optic tunable filters (AOTF) in the microsecond scale for alternative line scanning in order to avoid the crosstalk while minimizing the time delay between two lasers on the same pixel location. In contrast, the pulsed interleaved excitation (PIE) technique synchronizes two pulsed lasers of different wavelengths in the nanosecond scale to enable measuring superfast dynamics of two fluorescent species simultaneously and yet quantitatively without the crosstalk contamination. This feature is critical for many cell biology applications, e.g. accurate determination of stoichiometry in FRET measurements for studying protein-protein interactions or cell signal events, detection of weaker bindings in FCCS by eliminating the false cross correlation due to the crosstalk. The PIE has been used with the time correlated single photon counting (TCSPC) electronics. Here, we describe a novel PIE development using the digital frequency domain (DFD) technique -- FastFLIM, which provides tunable PIE setups and synchronized gating detections, tailored and optimized to specific applications. A few PIE setups by FastFLIM and measurement examples are described. Combined with the sensitivity of Alba and Q2 systems, the PIE allowed us to quantitatively measure the fast dynamics of single molecules.

  1. Effective neutron temperature measurements in well moderated reactor by the reactivity coefficient method

    International Nuclear Information System (INIS)

    Raisic, N.; Klinc, T.

    1968-11-01

    The ratio of the reactivity changes of a nuclear reactor produced by successive introduction of two different neutron absorbers in the reactor core, has been measured and information on effective neutron temperature at a particular point obtained. Boron was used as a l/v absorber and cadmium as an absorber sensiti ve to neutron temperature. Effective neutron temperature distribution has been deduced by moving absorbers across the reactor core and observing the corresponding reactivity changes. (author)

  2. Application of reactivity method to MTR fuel burn-up measurement

    International Nuclear Information System (INIS)

    Zuniga, A.; Ravnik, M.; Cuya, R.

    2001-01-01

    Fuel element burn-up has been measured for the first time by reactivity method in a MTR reactor. The measurement was performed in RP-10 reactor of Peruvian Institute for Nuclear Energy (IPEN) in Lima. It is a pool type 10MW material testing reactor using standard 20% enriched uranium plate type fuel elements. A fresh element and an element with well defined burn-up were selected as reference elements. Several elements in the core were selected for burn-up measurement. Each of them was replaced in its original position by both reference elements. Change in excess reactivity was measured using control rod calibration curve. The burn-up reactivity worth of fuel elements was plotted as a function of their calculated burnup. Corrected burn-up values of the measured fuel elements were calculated using the fitting function at experimental reactivity for all elements. Good agreement between measured and calculated burn-up values was observed indicating that the reactivity method can be successfully applied also to MTR fuel element burn-up determination.(author)

  3. High temperature doppler effect experiment for 238U at FCA. 1. Reactivity worth measurement with a small heated sample up to 1,500degC

    International Nuclear Information System (INIS)

    Okajima, Shigeaki; Oigawa, Hiroyuki; Mukaiyama, Takehiko; Andoh, Masaki

    1996-01-01

    The experimental device for Doppler effect measurement was developed for the Fast Critical Assembly of Japan Atomic Energy Research Institute. The Doppler effect up to 1,500degC can be measured with this device. The experimental data is to be used for evaluating and improving the calculation method of the Doppler effect in higher temperature range. The measurement technique is based on a reactivity worth measurement with a heated sample. The device is made of tungsten for the high temperature parts and stainless steel for the other structural parts. The measurements were carried out in a mock-up core of an oxide-fueled fast reactor. In the analysis of the experimental data, the Doppler reactivity worth was calculated by a first order perturbation theory and JENDL-3.2 library. A collision probability cell code with ultra-fine group structure, PEACO-X, was used to obtain the precise effective cross sections in a pin cell model of the Doppler sample. The calculation underestimates Doppler effect by about 5% in high temperature range. The Doppler effect above 1,500degC was estimated by the extrapolation of the measured data below this temperature. When the calculated and extrapolated Doppler reactivity worths at 2,000degC were compared, a good agreement between them was obtained. The significant improvement of calculation reliability of the Doppler effect in the higher temperature range was achieved by this experiment. (author)

  4. Lifetime measurement in Proserpine by reactivity modulation (1960)

    International Nuclear Information System (INIS)

    Clouet d'Orval, C.; Tachon, J.; Bertrand, J.; Lecoustey, P.

    1960-01-01

    The measurement method consists in varying the neutron flux periodically by means of an oscillator with cadmium sectors. From the signal received on a detector the lifetime τ can be determined; for various velocities ω, we have: (n/δn) 2 = (β eff /δk) 2 + (τ/δk) 2 ω 2 . Various corrections are involved, in particular the calculation of the rates of different harmonics in the oscillator signal. (author) [fr

  5. Measurements of Prompt and MHD-Induced Fast Ion Loss from National Spherical Torus Experiment Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    D.S. Darrow; S.S. Medley; A.L. Roquemore; W.W. Heidbrink; A. Alekseyev; F.E. Cecil; J. Egedal; V.Ya. Goloborod' ko; N.N. Gorelenkov; M. Isobe; S. Kaye; M. Miah; F. Paoletti; M.H. Redi; S.N. Reznik; A. Rosenberg; R. White; D. Wyatt; V.A. Yavorskij

    2002-10-15

    A range of effects may make fast ion confinement in spherical tokamaks worse than in conventional aspect ratio tokamaks. Data from neutron detectors, a neutral particle analyzer, and a fast ion loss diagnostic on the National Spherical Torus Experiment (NSTX) indicate that neutral beam ion confinement is consistent with classical expectations in quiescent plasmas, within the {approx}25% errors of measurement. However, fast ion confinement in NSTX is frequently affected by magnetohydrodynamic (MHD) activity, and the effect of MHD can be quite strong.

  6. Comparison of Total OH Reactivity Measurement Methods in Ambient Air between a Comparative Reactivity Method using PTR-MS and a LASER Technique

    Science.gov (United States)

    Okazaki, H.; Osada, T.; Nakashima, Y.; Kato, S.; Kajii, Y.

    2008-12-01

    OH radical plays an important role in atmospheric chemistry. OH reactivity measurement is essential to understand atmospheric chemical reaction processes. We have developed LASER technique to measure OH reactivity. This system requires both pump and probe lasers and high vacuum system. We have to pay a lot of efforts to bring the instrument in the field for ambient observation. Therefore we have developed a comparative reactivity method for measuring total OH reactivity recently. Since this method does not need a large space and complicated devices, it makes relatively easy to measure OH reactivity anywhere. The result of this non-laser OH reactivity measurement was compared with that of laser pump and probe technique as conducted an intensive field measurement of sub-urban air in Tokyo, July 2008. In comparative reactivity method, a regent species (X), which is ideally not present in ambient air, is introduced into the flow tube reactor and its concentration (C1) is monitored by a suitable detector under nitrogen atmospheric condition. A constant amount of OH radicals is then introduced into the flow tube to react with X under either nitrogen atmosphere (the concentration of X became C2) or ambient air (the concentration of X became C3). Total OH reactivity can be calculated by comparing C1, C2 and C3. OH radicals were produced in the photolysis of water vapor by a UV lamp. In our experiment, Pyrrole is selected as X and PTR-MS is used as a detector. The concentrations of NO, NO2, CO, SO2 were also measured. In some case, the two methods indicated some differences, for example, OH reactivity of 10 to 30 s-1 measured by LASER technique while the comparative reactivity method showed the value of only 5 to 12 s-1.This reason appears to be humidity dependence of PTR-MS sensitivity. Good agreements, for trends and absolute values, were found for comparison between the two methods during another day of experiment where both methods reveal OH reactivity ranging between

  7. IASI measurements of reactive trace species in biomass burning plumes

    Directory of Open Access Journals (Sweden)

    P.-F. Coheur

    2009-08-01

    Full Text Available This work presents observations of a series of short-lived species in biomass burning plumes from the Infrared Atmospheric Sounding Interferometer (IASI, launched onboard the MetOp-A platform in October 2006. The strong fires that have occurred in the Mediterranean Basin – and particularly Greece – in August 2007, and those in Southern Siberia and Eastern Mongolia in the early spring of 2008 are selected to support the analyses. We show that the IASI infrared spectra in these fire plumes contain distinctive signatures of ammonia (NH3, ethene (C2H4, methanol (CH3OH and formic acid (HCOOH in the atmospheric window between 800 and 1200 cm−1, with some noticeable differences between the plumes. Peroxyacetyl nitrate (CH3COOONO2, abbreviated as PAN was also observed with good confidence in some plumes and a tentative assignment of a broadband absorption spectral feature to acetic acid (CH3COOH is made. For several of these species these are the first reported measurements made from space in nadir geometry. The IASI measurements are analyzed for plume height and concentration distributions of NH3, C2H4 and CH3OH. The Greek fires are studied in greater detail for the days associated with the largest emissions. In addition to providing information on the spatial extent of the plume, the IASI retrievals allow an estimate of the total mass emissions for NH3, C2H4 and CH3OH. Enhancement ratios are calculated for the latter relative to carbon monoxide (CO, giving insight in the chemical processes occurring during the transport, the first day after the emission.

  8. Total OH reactivity measurements aboard the Zeppelin NT during the PEGASOS campaign 2012: Contributions of substance classes to the total OH reactivity

    Science.gov (United States)

    Wegener, Robert; Jäger, Julia; Hofzumahaus, Andreas; Rohrer, Franz; Bohn, Birger; Brauers, Theo; Broch, Sebastian; Gomm, Sebastian; Häseler, Rolf; Holland, Frank; Kaiser, Jennifer B.; Keutsch, Frank; Li, Xin; Lohse, Insa; Lu, Keding; Tillmann, Ralf; Wolfe, Glenn M.; Mentel, Thomas F.; Kiendler-Scharr, Astrid; Wahner, Andreas

    2014-05-01

    The hydroxyl (OH) radical is the main oxidant of atmospheric traces gases. The quantification of its sources and sinks is necessary to fully comprehend the OH concentration. Due to difficulties quantifying all the individual compounds contributing to the OH loss, the direct quantification of the OH loss termed as the total OH reactivity is a crucial approach to establish the budget of OH. Especially in forested areas, where OH reactivity is dominated by highly reactive organic compounds, the directly measured total OH reactivity could not be explained by individual trace gas measurements in recent field campaigns. This difference is termed 'missing reactivity'. Here, we present OH reactivity data together with data of volatile organic compounds (VOC) and other individual sinks of OH measured on board of the Zeppelin NT in summer 2012. The campaign was part of the Pan-European Gas AeroSOls-climate interaction Study (PEGASOS) and was performed from May to July 2012 in the area of Rotterdam (the Netherlands) and Bologna (Italy). Total OH reactivity and VOC were analyzed together with OH, HO2, CO, formaldehyde, NOx, HONO, ozone, photolysis frequencies, particle number concentrations and meteorological parameters. For these measurements the Zeppelin NT was flying at a low speed (50 km/h) and between altitudes of 100 and 900 m above ground which enabled the investigation of the vertical structure of the lower troposphere where most of the trace gas degradation takes place. On average, the total OH reactivity was 6.1 ± 1.2 s-1 over the area of Rotterdam and 3.8 ± 1.4 s-1 over the region of Bologna. During almost the entire campaign, the measured total OH reactivity could be explained by the contributions of VOC and other measured species. Only measurement in the nocturnal boundary layer, where anthropogenic emissions were enriched, showed missing reactivity which could not be related to measured compounds. Oxygenated volatile organic compounds (OVOC) contributed the

  9. K {sub infinity} measurements of HTR lattices by oscillated zero reactivity technique

    Energy Technology Data Exchange (ETDEWEB)

    Benedetti, F.; Brighenti, G.; Chiodi, P.L.; Ghilardotti, G.; Guiliani, C.

    1972-06-15

    The principles of the K {sub infinity} measurement of a HTR lattice, carried out by the oscillated zero reactivity method have been reported at the 9th DCPM. The RB-2 reactor modifications, requested for these measurements have been shown at the 10th DCPM. This report summarizes the modified RB-2 reactor characteristics, the present status of measurements, some preliminary results, and, the next measurements program. The report reflects the status of the work at the end of May 1972.

  10. Temporal evolution of confined fast-ion velocity distributions measured by collective Thomson scattering in TEXTOR

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Bindslev, Henrik; Porte, L.

    2008-01-01

    Fast ions created in the fusion processes will provide up to 70% of the heating in ITER. To optimize heating and current drive in magnetically confined plasmas insight into fast-ion dynamics is important. First measurements of such dynamics by collective Thomson scattering (CTS) were recently rep...

  11. BN600 reactivity definition

    International Nuclear Information System (INIS)

    Zheltyshev, V.; Ivanov, A.

    2000-01-01

    Since 1980, the fast BN600 reactor with sodium coolant has been operated at Beloyarsk Nuclear Power Plant. The periodic monitoring of the reactivity modifications should be implemented in compliance with the standards and regulations applied in nuclear power engineering. The reactivity measurements are carried out in order to confirm the basic neutronic features of a BN600 reactor. The reactivity measurements are aimed to justify that nuclear safety is provided in course of the in-reactor installation of the experimental core components. Two reactivity meters are to be used on BN600 operation: 1. Digital on-line reactivity calculated under stationary reactor operation on power (approximation of the point-wise kinetics is applied). 2. Second reactivity meter used to define the reactor control rod operating components efficiency under reactor startup and take account of the changing efficiency of the sensor, however, this is more time-consumptive than the on-line reactivity meter. The application of two reactivity meters allows for the monitoring of the reactor reactivity under every operating mode. (authors)

  12. A simple reactivity feedback model accounting for radial core expansion effects in the liquid metal fast reactor

    International Nuclear Information System (INIS)

    Kwon, Young Min; Lee, Yong Bum; Chang, Won Pyo; Haha, Do Hee

    2002-01-01

    The radial core expansion due to the structure temperature rise is one of major negative reactivity insertion mechanisms in metallic fueled reactor. Thermal expansion is a result of both the laws of nature and the particular core design and it causes negative reactivity feedback by the combination of increased core volume captures and increased core surface leakage. The simple radial core expansion reactivity feedback model developed for the SSC-K code was evaluated by the code-to-code comparison analysis. From the comparison results, it can be stated that the radial core expansion reactivity feedback model employed into the SSC-K code may be reasonably accurate in the UTOP analysis

  13. A simple reactivity feedback model accounting for radial core expansion effects in the liquid metal fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Young Min; Lee, Yong Bum; Chang, Won Pyo; Haha, Do Hee [KAERI, Taejon (Korea, Republic of)

    2002-10-01

    The radial core expansion due to the structure temperature rise is one of major negative reactivity insertion mechanisms in metallic fueled reactor. Thermal expansion is a result of both the laws of nature and the particular core design and it causes negative reactivity feedback by the combination of increased core volume captures and increased core surface leakage. The simple radial core expansion reactivity feedback model developed for the SSC-K code was evaluated by the code-to-code comparison analysis. From the comparison results, it can be stated that the radial core expansion reactivity feedback model employed into the SSC-K code may be reasonably accurate in the UTOP analysis.

  14. Application of Fast Dynamic Allan Variance for the Characterization of FOGs-Based Measurement While Drilling

    Directory of Open Access Journals (Sweden)

    Lu Wang

    2016-12-01

    Full Text Available The stability of a fiber optic gyroscope (FOG in measurement while drilling (MWD could vary with time because of changing temperature, high vibration, and sudden power failure. The dynamic Allan variance (DAVAR is a sliding version of the Allan variance. It is a practical tool that could represent the non-stationary behavior of the gyroscope signal. Since the normal DAVAR takes too long to deal with long time series, a fast DAVAR algorithm has been developed to accelerate the computation speed. However, both the normal DAVAR algorithm and the fast algorithm become invalid for discontinuous time series. What is worse, the FOG-based MWD underground often keeps working for several days; the gyro data collected aboveground is not only very time-consuming, but also sometimes discontinuous in the timeline. In this article, on the basis of the fast algorithm for DAVAR, we make a further advance in the fast algorithm (improved fast DAVAR to extend the fast DAVAR to discontinuous time series. The improved fast DAVAR and the normal DAVAR are used to responsively characterize two sets of simulation data. The simulation results show that when the length of the time series is short, the improved fast DAVAR saves 78.93% of calculation time. When the length of the time series is long ( 6 × 10 5 samples, the improved fast DAVAR reduces calculation time by 97.09%. Another set of simulation data with missing data is characterized by the improved fast DAVAR. Its simulation results prove that the improved fast DAVAR could successfully deal with discontinuous data. In the end, a vibration experiment with FOGs-based MWD has been implemented to validate the good performance of the improved fast DAVAR. The results of the experience testify that the improved fast DAVAR not only shortens computation time, but could also analyze discontinuous time series.

  15. Application of Fast Dynamic Allan Variance for the Characterization of FOGs-Based Measurement While Drilling.

    Science.gov (United States)

    Wang, Lu; Zhang, Chunxi; Gao, Shuang; Wang, Tao; Lin, Tie; Li, Xianmu

    2016-12-07

    The stability of a fiber optic gyroscope (FOG) in measurement while drilling (MWD) could vary with time because of changing temperature, high vibration, and sudden power failure. The dynamic Allan variance (DAVAR) is a sliding version of the Allan variance. It is a practical tool that could represent the non-stationary behavior of the gyroscope signal. Since the normal DAVAR takes too long to deal with long time series, a fast DAVAR algorithm has been developed to accelerate the computation speed. However, both the normal DAVAR algorithm and the fast algorithm become invalid for discontinuous time series. What is worse, the FOG-based MWD underground often keeps working for several days; the gyro data collected aboveground is not only very time-consuming, but also sometimes discontinuous in the timeline. In this article, on the basis of the fast algorithm for DAVAR, we make a further advance in the fast algorithm (improved fast DAVAR) to extend the fast DAVAR to discontinuous time series. The improved fast DAVAR and the normal DAVAR are used to responsively characterize two sets of simulation data. The simulation results show that when the length of the time series is short, the improved fast DAVAR saves 78.93% of calculation time. When the length of the time series is long ( 6 × 10 5 samples), the improved fast DAVAR reduces calculation time by 97.09%. Another set of simulation data with missing data is characterized by the improved fast DAVAR. Its simulation results prove that the improved fast DAVAR could successfully deal with discontinuous data. In the end, a vibration experiment with FOGs-based MWD has been implemented to validate the good performance of the improved fast DAVAR. The results of the experience testify that the improved fast DAVAR not only shortens computation time, but could also analyze discontinuous time series.

  16. Measuring reactive oxygen and nitrogen species with fluorescent probes: challenges and limitations

    Science.gov (United States)

    Kalyanaraman, Balaraman; Darley-Usmar, Victor; Davies, Kelvin J.A.; Dennery, Phyllis A.; Forman, Henry Jay; Grisham, Matthew B.; Mann, Giovanni E.; Moore, Kevin; Roberts, L. Jackson; Ischiropoulos, Harry

    2013-01-01

    The purpose of this position paper is to present a critical analysis of the challenges and limitations of the most widely used fluorescent probes for detecting and measuring reactive oxygen and nitrogen species. Where feasible, we have made recommendations for the use of alternate probes and appropriate analytical techniques that measure the specific products formed from the reactions between fluorescent probes and reactive oxygen and nitrogen species. We have proposed guidelines that will help present and future researchers with regard to the optimal use of selected fluorescent probes and interpretation of results. PMID:22027063

  17. Critical cerebral perfusion pressure at high intracranial pressure measured by induced cerebrovascular and intracranial pressure reactivity.

    Science.gov (United States)

    Bragin, Denis E; Statom, Gloria L; Yonas, Howard; Dai, Xingping; Nemoto, Edwin M

    2014-12-01

    The lower limit of cerebral blood flow autoregulation is the critical cerebral perfusion pressure at which cerebral blood flow begins to fall. It is important that cerebral perfusion pressure be maintained above this level to ensure adequate cerebral blood flow, especially in patients with high intracranial pressure. However, the critical cerebral perfusion pressure of 50 mm Hg, obtained by decreasing mean arterial pressure, differs from the value of 30 mm Hg, obtained by increasing intracranial pressure, which we previously showed was due to microvascular shunt flow maintenance of a falsely high cerebral blood flow. The present study shows that the critical cerebral perfusion pressure, measured by increasing intracranial pressure to decrease cerebral perfusion pressure, is inaccurate but accurately determined by dopamine-induced dynamic intracranial pressure reactivity and cerebrovascular reactivity. Cerebral perfusion pressure was decreased either by increasing intracranial pressure or decreasing mean arterial pressure and the critical cerebral perfusion pressure by both methods compared. Cortical Doppler flux, intracranial pressure, and mean arterial pressure were monitored throughout the study. At each cerebral perfusion pressure, we measured microvascular RBC flow velocity, blood-brain barrier integrity (transcapillary dye extravasation), and tissue oxygenation (reduced nicotinamide adenine dinucleotide) in the cerebral cortex of rats using in vivo two-photon laser scanning microscopy. University laboratory. Male Sprague-Dawley rats. At each cerebral perfusion pressure, dopamine-induced arterial pressure transients (~10 mm Hg, ~45 s duration) were used to measure induced intracranial pressure reactivity (Δ intracranial pressure/Δ mean arterial pressure) and induced cerebrovascular reactivity (Δ cerebral blood flow/Δ mean arterial pressure). At a normal cerebral perfusion pressure of 70 mm Hg, 10 mm Hg mean arterial pressure pulses had no effect on

  18. Are there sex differences in Fetal Abdominal Subcutaneous Tissue (FAST) measurements?

    LENUS (Irish Health Repository)

    Farah, Nadine

    2012-02-01

    OBJECTIVE: To determine if Fetal Abdominal Subcutaneous Tissue (FAST) measurements using antenatal ultrasound differ between male and female fetuses. STUDY DESIGN: Women who had an ultrasound examination for fetal growth between 20 and 40 weeks gestation were studied. Women with diabetes mellitus were excluded. The fetal anterior abdominal subcutaneous tissue was measured on the anterior abdominal wall in millimetres anterior to the margins of the ribs, using magnification at the level of the abdominal circumference. The fetal sex was recorded after delivery. RESULTS: A total of 557 fetuses were measured, 290 male and 267 female. The FAST measurements increased with gestational age. The FAST increased at the same rate for both male and female fetuses and at any given week there was no sex difference. CONCLUSIONS: The increased fat composition in females reported after birth was not found in abdominal wall subcutaneous fat measurements using ultrasound during pregnancy. Antenatal centile charts for FAST do not need to be based on sex.

  19. Reactivity and neutron emission measurements of highly burnt PWR fuel rod samples

    International Nuclear Information System (INIS)

    Murphy, M.F.; Jatuff, F.; Grimm, P.; Seiler, R.; Brogli, R.; Meier, G.; Berger, H.-D.; Chawla, R.

    2006-01-01

    Fuel rods with burnup values beyond 50 GWd/t are characterised by relatively large amounts of fission products and a high abundance of major and minor actinides. Of particular interest is the change in the reactivity of the fuel as a function of burnup and the capability of modern codes to predict this change. In addition, the neutron emission from burnt fuel has important implications for the design of transport and storage facilities. Measurements have been made of the reactivity effects and the neutron emission rates of highly burnt uranium oxide and mixed oxide fuel rod samples coming from a pressurised water reactor (PWR). The reactivity measurements have been made in a PWR lattice in the PROTEUS zero-energy reactor moderated in turn with: water, a water and heavy water mixture and water containing boron. A combined transport flask and sample changer was used to insert the 400 mm long burnt fuel rod segments into the reactor. Both control rod compensation and reactor period methods were used to determine the reactivities of the samples. For the range of burnup values investigated, an interesting exponential relationship has been found between the neutron emission rate and the measured reactivity

  20. Micrometeorological measurements of ammonia and total reactive nitrogen exchange over semi-natural peatland

    Science.gov (United States)

    Brümmer, Christian; Richter, Undine; Schrader, Frederik; Kutsch, Werner

    2015-04-01

    Intensive agriculture generates a substantial atmospheric burden for nitrogen-limited ecosystems such as peatlands when the latter are located in close vicinity to arable sites and animal houses. The exchange of reactive nitrogen compounds between these bog ecosystems and the atmosphere is still not very well understood due to the lack of suitable measurement techniques. With recent advancements in laser spectrometry, we used a quantum cascade laser spectrometer as well as a custom-built total reactive atmospheric nitrogen (ΣNr) converter (TRANC) coupled to a fast-response chemiluminescence detector to measure NH3 and ΣNr concentrations, respectively. The analyzers' high temporal resolution allowed for determination of the respective nitrogen exchange within eddy covariance-based setups. Field campaigns were conducted at a northwestern German peatland site that is surrounded by an area of highly fertilized agricultural land and intensive livestock production (~1 km distance). The field site is part of a natural park with a very small remaining protected zone of less than 2 km x 2 km. Ammonia and ΣNr concentrations were highly variable between 2 to 110 ppb and 10 to 120 ppb, respectively. Peak values coincided with main fertilization periods on the neighboring agricultural land in early spring and fall. The trend in weekly averaged ΣNr concentrations from TRANC measurements was in good agreement with results from KAPS denuder filter systems when the latter were combined with the missing and apparently highly variable NOx contribution. Wind direction and land use in the closer vicinity clearly regulated whether ΣNr concentrations were NH3 or NOx-dominated. Ammonia uptake rates between 40 ng N m-2 s-1 and near-neutral exchange were observed. The cumulative net uptake for the period of investigation was ~700 g N ha-1 resulting in a dry net deposition of ~4 kg N ha-1 when extrapolated to an entire year, whereas KAPS denuder measurements in combination with dry

  1. Comparison of OH reactivity measurements in the atmospheric simulation chamber SAPHIR

    Science.gov (United States)

    Fuchs, Hendrik; Novelli, Anna; Rolletter, Michael; Hofzumahaus, Andreas; Pfannerstill, Eva Y.; Kessel, Stephan; Edtbauer, Achim; Williams, Jonathan; Michoud, Vincent; Dusanter, Sebastien; Locoge, Nadine; Zannoni, Nora; Gros, Valerie; Truong, Francois; Sarda-Esteve, Roland; Cryer, Danny R.; Brumby, Charlotte A.; Whalley, Lisa K.; Stone, Daniel; Seakins, Paul W.; Heard, Dwayne E.; Schoemaecker, Coralie; Blocquet, Marion; Coudert, Sebastien; Batut, Sebastien; Fittschen, Christa; Thames, Alexander B.; Brune, William H.; Ernest, Cheryl; Harder, Hartwig; Muller, Jennifer B. A.; Elste, Thomas; Kubistin, Dagmar; Andres, Stefanie; Bohn, Birger; Hohaus, Thorsten; Holland, Frank; Li, Xin; Rohrer, Franz; Kiendler-Scharr, Astrid; Tillmann, Ralf; Wegener, Robert; Yu, Zhujun; Zou, Qi; Wahner, Andreas

    2017-10-01

    Hydroxyl (OH) radical reactivity (kOH) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements (limit of detection CRM) has a higher limit of detection of 2 s-1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapour or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds (mixing ratio of OH reactants were up to 10 ppbv). In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM

  2. Computation, measurement and analysis of the reactivity-to-power-transfer-function for the sodium cooled nuclear power plant KNK I

    International Nuclear Information System (INIS)

    Hoppe, P.; Mitzel, F.

    1977-02-01

    The Reactivity-to-Power-Transfer-Function for the sodium cooled nuclear power plant KNK I (Kompakte Natriumgekuehlte Kernenergieanlage) has been measured and compared with theoretical results. The measurements have been performed with the help of pseudostochastic reactivity perturbations. The transfer function has been determined by computing the auto- and cross-power-spectral-densities for the reactivity- and neutron flux signals. The agreement between the experimental and theoretical transfer function could be improved by adjusting the reactivity coefficients. The applications of these measurements with respect to reactor diagnosis and malfunction detection are discussed. For this purpose the accuracy of the measured transfer function is of great importance. Therefore an extensive error analysis has been performed. It turned out, that the inherent instability of the reactor without control system and the feedback by the primary coolant system were the reasons for comparatively big systematical errors. The conditions have been derived under which these types of errors can be considerably reduced. The conclusions can also be applied to analogical measurements at fast sodium cooled reactors. Because of their inherent stability the systematical errors will be reduced. (orig.) [de

  3. Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Science.gov (United States)

    Hansen, R. F.; Blocquet, M.; Schoemaecker, C.; Léonardis, T.; Locoge, N.; Fittschen, C.; Hanoune, B.; Stevens, P. S.; Sinha, V.; Dusanter, S.

    2015-10-01

    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios

  4. Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Malinowski, K.; Mirowski, R.; Lotte, Ph.; Gunn, J.; Pascal, J-Y.; Colledani, G.; Basiuk, V.; Goniche, M.; Lipa, M.

    2010-01-01

    The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

  5. First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak

    Science.gov (United States)

    Rodriguez-Ramos, M.; Garcia-Munoz, M.; Jimenez-Ramos, M. C.; Garcia Lopez, J.; Galdon-Quiroga, J.; Sanchis-Sanchez, L.; Ayllon-Guerola, J.; Faitsch, M.; Gonzalez-Martin, J.; Hermann, A.; de Marne, P.; Rivero-Rodriguez, J. F.; Sieglin, B.; Snicker, A.; the ASDEX Upgrade Team

    2017-10-01

    A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument function that includes the scintillator efficiency, collimator geometry, optical transmission and camera efficiency has been constructed. The scintillator response to deuterium ions in the relevant energy range of fast-ions has been characterized using a tandem accelerator. Absolute flux of neutral beam injection (NBI) prompt losses has been obtained in magnetohydrodynamic quiescent plasmas. The temporal evolution of the heat load measured with FILD follows that measured at the FILD entrance obtained with an Infra-Red camera looking at the FILD detector head. ASCOT simulations are in good agreement with the absolute heat load of NBI prompt losses measured with FILD.

  6. Low temperature fiber optic pyrometer for fast time resolved temperature measurements

    Science.gov (United States)

    Willsch, M.; Bosselmann, T.; Gaenshirt, D.; Kaiser, J.; Villnow, M.; Banda, M.

    2016-05-01

    Low temperature Pyrometry at temperatures beyond 150°C is limited in the measurement speed due to slow pyroelectric detectors. To detect the circumferential temperature distribution of fast rotating machines a novel Fiber Optical Pyrometer Type is presented here.

  7. Optimal Fasting Time before Measurement of Serum Triglyceride Levels in Healthy Volunteers.

    Science.gov (United States)

    Pongsuthana, Surapun; Tivatunsakul, Naris

    2016-02-01

    Coronary heart disease is a major public health problem. Elevated triglyceride levels are a risk factor for atherosclerosis and coronary heart disease. Food intake interferes with the measurement of serum triglyceride levels, and in previous studies, fasting for 12 hours was recommended before blood sampling. In real-world practice, long fasting times cause patient discomfort and poor compliance, and the present study was, therefore, designed to determine the appropriate fasting time prior to measuring serum triglyceride levels. To determine the appropriate fasting time before measuring serum triglyceride levels. This was a pilot study performed using healthy volunteers aged between 20 and 30 years old from November 2013 to December 2013 at Rajavithi Hospital. The first blood sample was measured in the morning after fasting over 12 hours. The subjects then took their regular breakfast, after which they fasted for 8 hours. Blood samples were taken 6 and 8 hours later and sent to the laboratory for measurement of serum triglyceride levels. 40 volunteers, of whom 25 were female, were enrolled. Their mean age was 25.9 ± 2.81 years old, and their mean weight, height, and body mass index were 61.5 ± 12.5 kg, 167.2 ± 8.3 cm and 21.84 ± 3.1 kg/m2, respectively. Mean fasting serum triglyceride level at 12 hours was 80.23 ± 36.33 mg/dl, at 6 hours it was 110.65 ± 73.45 mg/dl, and at 8 hours it was 75.62 ± 46.81 mg/dl. The group fasting for 12 hours had significantly lower serum triglyceride levels than the group fasting for 6 hours (p-value = 0.003), but no significant difference was found between the group fasting for 12 hours and the one fasting for 8 hours (p-value = 0.493). The present study showed no significant difference in triglyceride levels in patients who had fasted or 8 hours and those who had done so for 12 hours. Fasting for only 8 hours before measurement of serum triglyceride may be sufficient.

  8. Fast micro Hall effect measurements on small pads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Petersen, Dirch Hjorth; Nielsen, Peter F.

    2011-01-01

    Sheet resistance, carrier mobility, and sheet carrier density are important parameters in semiconductor production, and it is therefore important to be able to rapidly and accurately measure these parameters even on small samples or pads. The interpretation of four-point probe measurements on small...... pads is non-trivial. In this paper we discuss how conformal mapping can be used to evaluate theoretically expected measurement values on small pads. Theoretical values calculated from analytical mappings of simple geometries are compared to the values found from the numerical conformal mapping...... of a square onto the infinite half-plane, where well-established solutions are known. Hall effect measurements are performed to show, experimentally, that it is possible to measure Hall mobility in less than one minute on squares as small as 7070 lm2 with a deviation of 66.5% on a 1r level from accurate...

  9. Measurement of Reactive Oxygen Species, Reactive Nitrogen Species, and Redox-Dependent Signaling in the Cardiovascular System: A Scientific Statement From the American Heart Association.

    Science.gov (United States)

    Griendling, Kathy K; Touyz, Rhian M; Zweier, Jay L; Dikalov, Sergey; Chilian, William; Chen, Yeong-Renn; Harrison, David G; Bhatnagar, Aruni

    2016-08-19

    Reactive oxygen species and reactive nitrogen species are biological molecules that play important roles in cardiovascular physiology and contribute to disease initiation, progression, and severity. Because of their ephemeral nature and rapid reactivity, these species are difficult to measure directly with high accuracy and precision. In this statement, we review current methods for measuring these species and the secondary products they generate and suggest approaches for measuring redox status, oxidative stress, and the production of individual reactive oxygen and nitrogen species. We discuss the strengths and limitations of different methods and the relative specificity and suitability of these methods for measuring the concentrations of reactive oxygen and reactive nitrogen species in cells, tissues, and biological fluids. We provide specific guidelines, through expert opinion, for choosing reliable and reproducible assays for different experimental and clinical situations. These guidelines are intended to help investigators and clinical researchers avoid experimental error and ensure high-quality measurements of these important biological species. © 2016 American Heart Association, Inc.

  10. Reactivity and neutron emission measurements of burnt PWR fuel rod samples in LWR-PROTEUS phase II

    International Nuclear Information System (INIS)

    Murphy, M. F.; Jatuff, F.; Grimm, P.; Seiler, R.; Brogli, R.; Meier, G.; Berger, H. D.; Chawla, R.

    2004-01-01

    Measurements have been made of the reactivity effects and the neutron emission rates of uranium oxide and mixed oxide burnt fuel samples having a wide range of burnup values and coming from a Pressurised Water Reactor (PWR). The reactivity measurements have been made in a PWR lattice moderated in turn with: water, a water and heavy water mixture, and water containing boron. An interesting relationship has been found between the neutron emission rate and the measured reactivity. (authors)

  11. Picosecond time measurement using ultra fast analog memories

    OpenAIRE

    Breton, D.; Delagnes, E.; Maalmi, J.

    2009-01-01

    International audience; The currently existing electronics dedicated to precise time measurement is mainly based on the use of constant fraction discriminators (CFD) associated with Time to Digital Converters (TDC). The constant fraction technique minimizes the time walk effect (dependency of timing on the pulse amplitude). Several attempts have been made to integrate CFD in multi-channel ASICs. But the time resolution measured on the most advanced one is of the order of 30 ps rms. Two main t...

  12. Effects of Biomass Feedstock on the Yield and Reactivity of Soot from Fast Pyrolysis at High Temperatures

    DEFF Research Database (Denmark)

    Trubetskaya, Anna; Jensen, Peter A.; Glarborg, Peter

    microscopy techniques, X-ray diffraction and N2-adsorption. The reactivity of soot was investigated by thermogravimetric analysis. The results showed that the reactivity of soot, generated at 1400°C was higher than that at 1250°C for all biomass types. Wood and wheat straw soot demonstrated differences......This study investigated the effect of feedstock on the yield, nanostructure and reactivity of soot. Woody and herbaceous biomass were pyrolyzed at high heating rates and temperatures of 1250 and 1400°C in a drop tube furnace. The collected solid residues were structurally characterized by electron...

  13. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  14. Surface reactivity measurements as required for grouping and read-across: An advanced FRAS protocol

    Science.gov (United States)

    Gandon, Arnaud; Werle, Kai; Neubauer, Nicole; Wohlleben, Wendel

    2017-06-01

    Oxidative stress is a widely accepted paradigm associated with different adverse outcomes of particulate matter, including nanomaterials. It has frequently been identified in in vitro and in vivo studies and different assays have been developed for this purpose. Here we describe a newly developed multi-dose protocol of the FRAS assay (Ferric Reduction Ability of Serum). The purpose of this SOP is the measurement of the surface reactivity of nanomaterials under physiological conditions. Antioxidative components as present in human blood serum (HBS) serve as reporter molecules. The assay separates the oxidative damage from the read-out of the reporter molecules. The results show significantly enhanced repeatability with better sensitivity towards low reactivity, enabling application of FRAS both to a rough grouping by reactive vs. passive nanomaterials and further to substantiation of read-across by enhanced resolution of the similarity between different nanoforms of the same substance.

  15. Surface reactivity measurements as required for grouping and read-across: An advanced FRAS protocol

    International Nuclear Information System (INIS)

    Gandon, Arnaud; Werle, Kai; Neubauer, Nicole; Wohlleben, Wendel

    2017-01-01

    Oxidative stress is a widely accepted paradigm associated with different adverse outcomes of particulate matter, including nanomaterials. It has frequently been identified in in vitro and in vivo studies and different assays have been developed for this purpose. Here we describe a newly developed multi-dose protocol of the FRAS assay (Ferric Reduction Ability of Serum). The purpose of this SOP is the measurement of the surface reactivity of nanomaterials under physiological conditions. Antioxidative components as present in human blood serum (HBS) serve as reporter molecules. The assay separates the oxidative damage from the read-out of the reporter molecules. The results show significantly enhanced repeatability with better sensitivity towards low reactivity, enabling application of FRAS both to a rough grouping by reactive vs. passive nanomaterials and further to substantiation of read-across by enhanced resolution of the similarity between different nanoforms of the same substance. (paper)

  16. Fast neutron measurements with 7Li and 6Li enriched CLYC scintillators

    International Nuclear Information System (INIS)

    Giaz, A.; Blasi, N.; Boiano, C.; Brambilla, S.; Camera, F.; Cattadori, C.; Ceruti, S.; Gramegna, F.; Marchi, T.; Mattei, I.; Mentana, A.; Million, B.; Pellegri, L.; Rebai, M.; Riboldi, S.; Salamida, F.; Tardocchi, M.

    2016-01-01

    The recently developed Cs 2 LiYCl 6 :Ce (CLYC) crystals are interesting scintillation detectors not only for their gamma energy resolution (<5% at 662 keV) but also for their capability to identify and measure the energy of both gamma rays and fast/thermal neutrons. The thermal neutrons were detected by the 6 Li(n,α)t reaction while for the fast neutrons the 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P neutron-capture reactions were exploited. The energy of the outgoing proton or α particle scales linearly with the incident neutron energy. The kinetic energy of the fast neutrons can be measured using both the Time Of Flight (TOF) technique and using the CLYC energy signal. In this work, the response to monochromatic fast neutrons (1.9–3.8 MeV) of two CLYC 1″×1″ crystals was measured using both the TOF and the energy signal. The observables were combined to identify fast neutrons, to subtract the thermal neutron background and to identify different fast neutron-capture reactions on 35 Cl, in other words to understand if the detected particle is an α or a proton. We performed a dedicated measurement at the CN accelerator facility of the INFN Legnaro National Laboratories (Italy), where the fast neutrons were produced by impinging a proton beam (4.5, 5.0 and 5.5 MeV) on a 7 LiF target. We tested a CLYC detector 6 Li-enriched at about 95%, which is ideal for thermal neutron measurements, in parallel with another CLYC detector 7 Li-enriched at more than 99%, which is suitable for fast neutron measurements.

  17. Television filmless technique for fast-process coordinate measurement

    International Nuclear Information System (INIS)

    Petrakov, A.V.

    1977-01-01

    Achievements in the application of television filmless method for recording transients have been analysed, as well as the causes limiting the quality of measuring lines: experimental equipment - TV system - computer. The perspectives are shown of developing the method by using new transmitting kinescopes and by stabilizing the size and location of their rasters in space

  18. Fast and precise luminosity measurement at the international linear

    Indian Academy of Sciences (India)

    The detectors of the ILC will feature a calorimeter system in the very forward region. The system comprises mainly two electromagnetic calorimeters: LumiCal, which is dedicated to the measurement of the absolute luminosity with highest precision and BeamCal, which uses the energy deposition from beamstrahlung pairs ...

  19. Fast and precise luminosity measurement at the international linear ...

    Indian Academy of Sciences (India)

    The detectors of the ILC will feature a calorimeter system in the very forward region. The system comprises mainly two electromagnetic calorimeters: LumiCal, which is dedicated to the measurement of the absolute luminosity with highest precision and BeamCal, which uses the energy deposition from beamstrahlung pairs ...

  20. Measurement of isothermal temperature reactivity coefficient at research reactor with IRT-4M fuel

    International Nuclear Information System (INIS)

    Bily, Tomas; Sklenka, Lubomir

    2014-01-01

    Highlights: • Isothermal coefficient of reactivity with IRT-4M fuel was measured. • Experiment was performed at VR-1 zero power reactor. • Tailor-made instrumentation was used. • MCNP code was used for analysis of experimental data. - Abstract: Transients analyses is of high importance for reactor safety studies. The temperature reactivity coefficients belong to key input parameters for such studies. However, the amount of experimental data for validation of such parameters for the conditions of research reactors operated with LEU fuel is limited. To improve the situation, a tailor-made experimental instrumentation has been recently developed at zero power research reactor VR-1 that allows for detailed measurement of temperature reactivity effects in lattices with IRT-4M fuel. The instrumentation enables by external water heater to change the temperature of fuel and surrounding water moderator in 2 × 2 positions of reactor grid in the range from 20 to 40 °C. Using the instrumentation the isothermal temperature reactivity effect was measured for a group of four eight-tube fuel assemblies in the above mentioned temperature range. Results were compared to MCNP calculations with the precise model of the VR-1 reactor. The MCNP code was further used for deeper analysis of experimental data

  1. Analytical estimation of control rod shadowing effect for excess reactivity measurement of High Temperature Engineering Test Reactor (HTTR)

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Masaaki; Yamashita, Kiyonobu; Fujimoto, Nozomu; Nojiri, Naoki; Takeuchi, Mitsuo; Fujisaki, Shingo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Tokuhara, Kazumi; Nakata, Tetsuo

    1998-05-01

    The control rod shadowing effect has been estimated analytically in application of the fuel addition method to excess reactivity measurement of High Temperature Engineering Test Reactor (HTTR). The movements of control rods in the procedure of the fuel addition method have been simulated in the analysis. The calculated excess reactivity obtained by the simulation depends on the combinations of measuring control rods and compensating control rods and varies from -10% to +50% in comparison with the excess reactivity calculated from the effective multiplication factor of the core where all control rods are fully withdrawn. The control rod shadowing effect is reduced by the use of plural number of measuring and compensation control rods because of the reduction in neutron flux deformation in the measuring procedure. As a result, following combinations of control rods are recommended; 1) Thirteen control rods of the center, first, and second rings will be used for the reactivity measurement. The reactivity of each control rod is measured by the use of the other twelve control rods for reactivity compensation. 2) Six control rods of the first ring will be used for the reactivity measurement. The reactivity of each control rod is measured by the use of the other five control rods for reactivity compensation. (author)

  2. Dose measurement of fast electrons with a modified Fricke solution

    International Nuclear Information System (INIS)

    Nemec, H.W.; Roth, J.; Luethy, H.

    1975-01-01

    A combination of two different modifications indicated in the literature about the ferrosulfate dosimetry is given. This permits a dose measurement which shows compared to the usual Fricke dosimetry above all following advantages: dose specification related to water; displacement of the absorption maximum in the perceptible spectral sphere; increase of the sensibility and lower influence of pollutions. The molar coefficient of extinction of the modified solution has been determined from 60 Co gamma irradiation and is epsilonsub(m) = 1.46 x 10 4 l x Mol -1 x cm -1 . The increase of extinction which has been measured with this method after the irradiation with 18 MeV electrons occurs linearly within the studied region to 1,200 rd at least, the G-value is 15.5. The indicated method renders possible a relative simple calibration of the ionization chambers used in the practice. (orig.) [de

  3. A Fast Digital Integrator for Magnetic Field Measurements at CERN

    CERN Document Server

    Arpaia, P; Cimmino, P; Giloteaux, D; Masi, A; García-Pérez, J; Spiezia, G; Walckiers, L

    2007-01-01

    A self-calibrating digital instrument for flux measurements on magnets for accelerators used in basic research on subnuclear particles is proposed. The instrument acquires voltage arising from rotating coils transducers with a theoretical resolution of 10 ppt and a maximum sampling frequency of 800 kS/s. Then, samples are integrated on-line and suitably processed in order to improve time resolution and flux accuracy. This allows the limits of state-of-the-art digital fluximeters, related mainly to newgeneration rotating coils, with trigger rate of 20 kHz and coils speed of 10 rps, to be overcome. The instrument has been prototyped at Magnetic Measurement and Testing (MTM) Group of European Laboratory for Nuclear Research (CERN), under a framework of cooperation with the University of Sannio. Details on hardware and firmware conception, as well as on experimental results of the instrument principle validation, and of the preliminary metrological characterization of the prototype, are provided.

  4. Fast light pulse measurements and temporal fluctuations in photomultipliers

    International Nuclear Information System (INIS)

    Miehe, J.A.; Sipp, B.

    1975-01-01

    This paper reviews the results on time fluctuations in high gain first dynode photomultipliers used in single photon timing experiments; the theoretical analysis of the measurement of the shape of light pulses is recalled and the previously obtained results concerning time dispersion in the photocathode, first dynode space are discussed. In addition, the influence of the variations of the electron transit time in the multiplier on the time resolution curves of the detector is examined: the curves obtained by leading-edge triggering of the anodic pulse show a strong dependence on the threshold level of the discriminator. A single-photoelectron timing resolution of 270ps is measured using a low leading edge discrimination [fr

  5. Gamma spectroscopy for fast in-situ measurements

    International Nuclear Information System (INIS)

    Lovranich, E.; Steger, F.; Urbanich, E.

    1990-01-01

    The problem is to determine the dose rate contributions from particular radionuclides deposited in the soil. The authors show how information from the gamma energy spectra for a particular measurement chain can be evaluated. In particular the chain has a portable germanium detector above the ground with a multichannel and an associated IBM-PC. A comparison of doses gained by this method and by soil samplings from different depths and sample preparation is made. (Quittner)

  6. Measurements of the energy spectrum of backscattered fast neutrons

    International Nuclear Information System (INIS)

    Segal, Y.

    1976-03-01

    Experimental measurements have been made of the energy spectra of neutrons transmitted through slabs of iron, lead and perspex for incident neutron energies of 0.5, 1.0, 1.5 and 1.8 MeV. The neutron energy measurements were made using a He-3 spectrometer. The dependence of the neutrons energy spectrum as a function of scattering thickness was determined. The neutrons source used was a 3MeV Van de Graaff accelerator with a tritium target using the H 3 (p,n) He 3 reaction. The results obtained by the investigator on energy dependence of transmitted neutrons as a function of thickness of scattering material were compared, where possible, with the results obtained by other workers. The comparisons indicated good agreement. The experiment's results are compared with MORSE Monte Carlo calculated values. It is worthwhile to note that direct comparison between measured cross section values and the recommended ones are very far from satisfactory. In almost all cases the calculated spectrum is harder than the experimental one, a situation common to the penetrating and the back-scattered flux

  7. Investigation of linear accelerator pulse delivery using fast organic scintillator measurements

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Andersen, Claus Erik; Lindvold, Lars René

    2010-01-01

    Fiber-coupled organic plastic scintillators present an attractive method for time-resolved dose measurements during radiotherapy. Most organic scintillators exhibit a fast response, making it possible to use them to measure individual high-energy X-ray pulses from a medical linear accelerator....... This can be used in complex treatment procedures such as gated intensity-modulated radiotherapy (IMRT)1, where the advantage of dose rate measurements of high temporal resolution is highly emphasized. We report on development of a fast data acquisition scintillator-based system as well as measurements...

  8. Validation of prospective portion size and latency to eat as measures of reactivity to snack foods.

    Science.gov (United States)

    van den Akker, Karolien; Bongers, Peggy; Hanssen, Imke; Jansen, Anita

    2017-09-01

    In experimental studies that investigate reactivity to the sight and smell of highly palatable snack foods, ad libitum food intake is commonly used as a behavioural outcome measure. However, this measure has several drawbacks. The current study investigated two intake-related measures not yet validated for food cue exposure research involving common snack foods: prospective portion size and latency to eat. We aimed to validate these measures by assessing prospective portion size and eating latencies in female undergraduate students who either underwent snack food exposure or a control exposure. Furthermore, we correlated prospective portion size and latency to eat with commonly used measures of food cue reactivity, i.e., self-reported desire to eat, salivation, and ad libitum food intake. Results showed increases in prospective portion size after food cue exposure but not after control exposure. Latency to eat did not differ between the two conditions. Prospective portion size correlated positively with desire to eat and food intake, and negatively with latency to eat. Latency to eat was also negatively correlated with desire to eat and food intake. It is concluded that the current study provides initial evidence for the prospective portion size task as a valid measure of reactivity to snack foods in a Dutch female and mostly healthy weight student population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. 'Beam-emission spectroscopy' diagnostics also measure edge fast-ion light

    International Nuclear Information System (INIS)

    Heidbrink, W W; Bortolon, A; McKee, G R; Smith, D R

    2011-01-01

    Beam-emission spectroscopy (BES) diagnostics normally detect fluctuations in the light emitted by an injected neutral beam. Under some circumstances, however, light from fast ions that charge exchange in the high neutral-density region at the edge of the plasma make appreciable contributions to the BES signals. This 'passive' fast-ion D α (FIDA) light appears in BES signals from both the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). One type of passive FIDA light is associated with classical orbits that traverse the edge. Another type is caused by instabilities that expel fast ions from the core; this light can complicate measurement of the instability eigenfunction.

  10. Improved Collective Thomson Scattering measurements of fast ions at ASDEX Upgrade

    DEFF Research Database (Denmark)

    Rasmussen, Jesper; Nielsen, Stefan Kragh; Stejner Pedersen, Morten

    2014-01-01

    Scattering (CTS) is well suited for reactor conditions and offers such an opportunity by providing measurements of the confined fast-ion distribution function resolved in space, time and 1D velocity space. We currently operate a CTS system at ASDEX Upgrade using a gyrotron which generates probing radiation......Understanding the behaviour of the confined fast ions is important in both current and future fusion experiments. These ions play a key role in heating the plasma and will be crucial for achieving conditions for burning plasma in next-step fusion devices. Microwave-based Collective Thomson...... at 105 GHz. A new setup using two independent receiver systems has enabled improved subtraction of the background signal, and hence the first accurate characterization of fast-ion properties. Here we review this new dual-receiver CTS setup and present results on fast-ion measurements based...

  11. Measuring fast electron distribution functions at intensities up to 10 21 W cm -2

    Science.gov (United States)

    Booth, N.; Clarke, R. J.; Doria, D.; Gizzi, L. A.; Gregori, G.; Hakel, P.; Koester, P.; Labate, L.; Levato, T.; Li, B.; Makita, M.; Mancini, R. C.; Pasley, J.; Rajeev, P. P.; Riley, D.; Robinson, A. P. L.; Wagenaars, E.; Waugh, J. N.; Woolsey, N. C.

    2011-10-01

    Here we present results from ultra-intense experiments demonstrating the viability of polarization spectroscopy as a diagnostic of the electron return current and spatial anisotropy and distribution function of the fast electron beam. The measurements extend to ultra-relativistic intensities of 10 21 W cm -2, including laser-plasma interaction regimes important for fast ignition studies, for example HiPER, and the development of secondary sources from next generation ultra-short pulse, ultra-intense laser facilities such as Astra-Gemini and ELI. As an in situ diagnostic, spectroscopic measurements are vital to understanding fast electron beams, enabling extrapolation of results to define fast ignition inertial confinement fusion and secondary source facilities.

  12. Reactivity worth measurement of the control blades of the University of Florida training reactor

    International Nuclear Information System (INIS)

    Quintero-Leyva, Barbaro

    1997-01-01

    A series of experiments were carried out in order to measure the reactivity worth of the safety and regulating blades of the University of Florida Training Reactor (UFTR) using the Inverse Kinetics, the Inverse Kinetics-Rod Drop method and the Power Ratio. The reactor's own instrumentation (compensated ion chamber) and an independent counting system (fission chamber) were used. A very smooth exponential decay of the flux was observed after 6s of the beginning of the transients using the reading of the reactor detector. The results of the measurements of the reactivity using both detectors were consistent and in good agreement. The compensated ion chamber showed a very smooth exponential behavior; this suggests that if we could record the power for a small sample time, say 0.1 s from the beginning of the transient, several additional research projects could be accomplished. First, precise intercomparison of the methods could be achieved if the statistics level is acceptable. Second, a precise description of the bouncing of the blades and its effects on the reactivity could be achieved. Finally, the design of a reactivity-meter could be based on such study. (author)

  13. Improvement the value of sodium void reactivity effect of the fast neutron reactor by the instrumentality of the Monte Carlo code

    OpenAIRE

    P.A. Maslov; V.I. Matveev; I.V. Malysheva

    2015-01-01

    To fulfill safety of fast sodium reactors in a beyond design-basis accident (BDBA) like unprotected loss of flow accident (ULOF), the sodium void reactivity effect (SVRE) should be close to zero. Its value depends on the fuel burnup – the higher burnup the higher value of SVRE. We analyze limitation of the fuel burnup in the core of a large sodium reactor imposed by SVRE. The model of a large sodium-cooled reactor core is chosen for analysis. Two fuel types are considered – MOX and nitride...

  14. Evaluation of the reactive nitrogen budget of the remote atmosphere in global models using airborne measurements

    Science.gov (United States)

    Murray, L. T.; Strode, S. A.; Fiore, A. M.; Lamarque, J. F.; Prather, M. J.; Thompson, C. R.; Peischl, J.; Ryerson, T. B.; Allen, H.; Blake, D. R.; Crounse, J. D.; Brune, W. H.; Elkins, J. W.; Hall, S. R.; Hintsa, E. J.; Huey, L. G.; Kim, M. J.; Moore, F. L.; Ullmann, K.; Wennberg, P. O.; Wofsy, S. C.

    2017-12-01

    Nitrogen oxides (NOx ≡ NO + NO2) in the background atmosphere are critical precursors for the formation of tropospheric ozone and OH, thereby exerting strong influence on surface air quality, reactive greenhouse gases, and ecosystem health. The impact of NOx on atmospheric composition and climate is sensitive to the relative partitioning of reactive nitrogen between NOx and longer-lived reservoir species of the total reactive nitrogen family (NOy) such as HNO3, HNO4, PAN and organic nitrates (RONO2). Unfortunately, global chemistry-climate models (CCMs) and chemistry-transport models (CTMs) have historically disagreed in their reactive nitrogen budgets outside of polluted continental regions, and we have lacked in situ observations with which to evaluate them. Here, we compare and evaluate the NOy budget of six global models (GEOS-Chem CTM, GFDL AM3 CCM, GISS E2.1 CCM, GMI CTM, NCAR CAM CCM, and UCI CTM) using new observations of total reactive nitrogen and its member species from the NASA Atmospheric Tomography (ATom) mission. ATom has now completed two of its four planned deployments sampling the remote Pacific and Atlantic basins of both hemispheres with a comprehensive suite of measurements for constraining reactive photochemistry. All six models have simulated conditions climatologically similar to the deployments. The GMI and GEOS-Chem CTMs have in addition performed hindcast simulations using the MERRA-2 reanalysis, and have been sampled along the flight tracks. We evaluate the performance of the models relative to the observations, and identify factors contributing to their disparate behavior using known differences in model oxidation mechanisms, heterogeneous loss pathways, lightning and surface emissions, and physical loss processes.

  15. Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System

    Directory of Open Access Journals (Sweden)

    Healy Robin

    2016-12-01

    Full Text Available The aim of this study was to assess the concurrent validity of the Optojump™ system (Microgate, Bolzano, Italy versus a force platform in the estimation of temporal and reactive strength measures. In two separate investigations, twenty physically active males performed double-leg and single-leg drop jumps from a box height of 0.3 m and a 10 s vertical bilateral hopping test. Contact time, flight time and total time (the sum of contact and flight time were concurrently assessed during single and double-leg drop jumps and during hopping. Jump height, the reactive strength index and the reactive strength ratio were also calculated from contact time and flight time. Despite intraclass correlation coefficients (ICCs for all variables being close to 1 (ICC > 0.975, a significant overestimation was found in contact time (0.005 ± 0.002 s and underestimations in flight time (0.005 ± 0.003 s, the reactive strength index (0.04 ± 0.02 m·s-1 and the reactive strength ratio (0.07 ± 0.04. Overestimations in contact time and underestimations in flight time were attributed to the physical design of the Optojump™ system as the transmitter and receiver units were positioned 0.003 m above the floor level. The Optojump™ demonstrated excellent overall temporal validity with no differences found between systems for total time. Coaches are advised to be consistent with the instrumentation used to assess athletes, however, in the case of comparison between reactive strength values collected with the Optojump™ and values collected with a force platform, regression equations are provided.

  16. Comparison of OH reactivity measurements in the atmospheric simulation chamber SAPHIR

    Directory of Open Access Journals (Sweden)

    H. Fuchs

    2017-10-01

    Full Text Available Hydroxyl (OH radical reactivity (kOH has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds by all instruments. The precision of the measurements (limit of detection  < 1 s−1 at a time resolution of 30 s to a few minutes is higher for instruments directly detecting hydroxyl radicals, whereas the indirect comparative reactivity method (CRM has a higher limit of detection of 2 s−1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO, water vapour or nitric oxide (NO. In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in

  17. Application of electrochemical potentio-kinetic reactivation method in fast classification of long-term heat effects on mateials for fast reactor sodium circuits

    International Nuclear Information System (INIS)

    Eremias, B.; Fresl, M.; Faja, V.

    1986-01-01

    Samples of modified corrosion resistant steels of the AISI 304 and AISI 316 types of various chemical composition and grain size, and samples of optimized corrosion resistant steels of the AISI 304 and AISI 316 types of nuclear purity and various grain size were investigated. The chemical composition and heat treatment conditions are tabulated. Sample preparation and testing are also described. Testing of the former group of samples showed that variability of chemical composition significantly affected susceptibility to intercrystalline corrosion and/or the degree of heat effect on the surface asessed as the size of the reactivation charge. The tabulated results show that the electrochemical response of the surface of the modified steels of the said types, in using the electrochemical potentio-kinetic reactivation method was higher for materials exposed to argon for 100 hours at a temperature of 600 degC than for materials exposed to argon over the same duration but at a temperature of 700 degC, and was higher at the same exposure for the AISI 304 type materials than for the AISI 316 type materials. The values of the reactivation charge for the latter group of samples are tabulated. No electrochemical response was recorded for samples of selected melts exposed for 500, 1,500, 5,000 and 10,000 hours at a temperature of 600 degC. With respect to rapid classification of long-term heat effects at temperatures of 600 and 700 degC the said method can also be recommended for testing the optimization of corrosion resistant steels of nuclear purity. The procedure proved the feasibility of indicating the minimum effective chromium content necessary for providing resistance to heat affection, and made possible its determination for the investigated materials. (J.B.)

  18. Fast recovery strain measurements in a nuclear test environment

    International Nuclear Information System (INIS)

    Kitchen, W.R.; Nauman, W.J.; Vollmer, D.W.

    1979-01-01

    The recovery of early-time (50 μs or less) strain gage data on structural response experiments in underground nuclear tests has been a continuing problem for experimenters at the Nevada Test Site. Strain measurement is one of the primary techniques used to obtain experimental data for model verification and correlation with predicted effects. Peak strains generally occur within 50 to 100 μs of the radiation exposure. Associated with the exposure is an intense electromagnetic impulse that produces potentials of kilovolts and currents of kiloamperes on the experimental structures. For successful operation, the transducer and associated recording system must recover from the initial noise overload and accurately track the strain response within about 50 μs of the nuclear detonation. A gaging and fielding technique and a recording system design that together accomplish these objectives are described. Areas discussed include: (1) noise source model; (2) experimental cassette design, gage application, grounding, and shielding; (3) cable design and shielding between gage and recorder; (4) recorder design including signal conditioner/amplifier, digital encoder, buffer memory, and uphole data transmission; and (5) samples of experimental data

  19. Measurement of resistance to flow across antroduodenal area during fasting.

    Science.gov (United States)

    Mearin, F; Azpiroz, F; Malagelada, J R

    1986-06-01

    Changes in antroduodenal resistance to flow may participate in the regulation of gastric emptying and duodenogastric reflux. Little is known, however, about the relationship between antroduodenal resistance and the physiological patterns of contractile activity in this area. We have developed an instrument that maintains an electronically regulated constant-pressure gradient of 2 mmHg across both ends of a flaccid cylinder positioned fluoroscopically across the pylorus. Because resistance bears a constant inverse relationship to flow at a fixed pressure gradient, changes in the recorded rate of airflow through the cylinder are a measure of antroduodenal resistance. In vitro studies showed that, under these conditions, airflow was a function of the diameter and length of the air path and the frequency and duration of external pressure waves greater than 2 mmHg. In vivo studies in four dogs examined the relationship between interdigestive phases of motor activity and variations in resistance exerted by the antroduodenal area. We found that flow rates varied markedly with each phase. Antroduodenal resistance was lowest during motor quiescence (phase I), rose gradually during irregular activity (phase II), and reached its peak during maximal contractile activity (phase III) (P less than 0.05). Resistance was similar for antegrade and retrograde flow. Additional studies suggested that the pyloric area contributes mostly to resistance during phase I, whereas duodenal resistance at least matches that of the pylorus during phase III.

  20. Ultra Fast Timing Measurements at $^{78}$Ni and $^{132}$Sn

    CERN Multimedia

    2002-01-01

    We propose to measure level lifetimes in the exotic nuclei of $^{81}$Ga and $^{80}$Ga in the vicinity of $^{78}$Ni and of $^{135}$Sb and $^{134}$Sb above $^{132}$Sn by the time-delayed technique. These are relatively simple nuclear systems with a few particles and/or holes outside of the doubly-magic core thus can be treated rather precisely within the shell model. The anticipated new structure information on these nuclei, and in particular the lifetime results will put constraints on the model parameters and will serve to verify their predictions. The selected nuclei are some of the most exotic ones just above $^{78}$Ni or $^{132}$Sn, where the transition rates can be studied at present. Of the strongest interest is the nucleus of $^{81}$Ga, which has only 3 valence protons outside of $^{78}$Ni with the lowest proton orbits being $p_{3/2}$ and $f_{5/2}$. The Ml transition between these states, although allowed by the selection rules, should be $\\textit{l}$-forbidden thus very slow. This should give rise to a...

  1. Measured Thermal and Fast Neutron Fluence Rates for ATF-1 Holders During ATR Cycle 157D

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 157D which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution.

  2. The fluence research of filter material for fast neutron fluence measurement

    International Nuclear Information System (INIS)

    Tang Xiding

    2010-01-01

    When the fast neutron fluence is measured by radioactivation techniques in the nuclear reactor the fast neutron is also filtered a little by the thermal neutron filter material, and if the filter material thickness increase the filtered fast neutron increases therewith. For fast neutron fluenc measurement, there are only cadmium, boron and gadolinium three elements filtering fluence can be calculated ordinarily. In order to calculate the filtered fast neutron fluence of the all elements in the filter material, the many total cross sections of nuclides had checked out from nuclear cross section data library, converted them into the same energy group structure, then element's total cross section, compound's total cross section and multilayer filters' total cross section had calculated from these total cross sections with same energy group structure, a new cross section data library can be obtained lastly through merging these cross sections into the old cross section data library used for neutron fluence measurement. The calculation analysis indicates that the results of the unit 2 surveillance capsule U of DAYA Bay NPP and the unit 1 surveillance capsule A of the Second Nuclear Power Plant of Qinshan by considering the all elements subtracting iron are smaller about 1.5% and 2.6% respectively than the ones only to consider cadmium, boron. The old measured results accord with the new values under the measurement uncertainty, are reliable. The new results are more accuracy. (authors)

  3. Investigation of Reactivity Feedback Mechanism of Axial and Radial Expansion Effect of Metal-Fueled Sodium-Cooled Fast Reactor

    International Nuclear Information System (INIS)

    Seong, Seung-Hwan; Choi, Chi-Woong; Jeong, Tae-Kyung; Ha, Gi-Seok

    2015-01-01

    The major inherent reactivity feedback models for a ceramic fuel used in a conventional light water reactor are Doppler feedback and moderator feedback. The metal fuel has these two reactivity feedback mechanisms previously mentioned. In addition, the metal fuel has two more reactivity feedback models related to the thermal expansion phenomena of the metal fuel. Since the metal fuel has a good capability to expand according to the temperature changes of the core, two more feedback mechanisms exist. These additional two feedback mechanism are important to the inherent safety of metal fuel and can make metal-fueled SFR safer than oxide-fueled SFR. These phenomena have already been applied to safety analysis on design extended condition. In this study, the effect of these characteristics on power control capability was examined through a simple load change operation. The axial expansion mechanism is induced from the change of the fuel temperature according to the change of the power level of PGSFR. When the power increases, the fuel temperatures in the metal fuel will increase and then the reactivity will decrease due to the axial elongation of the metal fuel. To evaluate the expansion effect, 2 cases were simulated with the same scenario by using MMS-LMR code developed at KAERI. The first simulation was to analyze the change of the reactor power according to the change of BOP power without the reactivity feedback model of the axial and radial expansion of the core during the power transient event. That is to say, the core had only two reactivity feedback mechanism of Doppler and coolant temperature

  4. Recursive Pyramid Algorithm-Based Discrete Wavelet Transform for Reactive Power Measurement in Smart Meters

    Directory of Open Access Journals (Sweden)

    Mahin K. Atiq

    2013-09-01

    Full Text Available Measurement of the active, reactive, and apparent power is one of the most fundamental tasks of smart meters in energy systems. Recently, a number of studies have employed the discrete wavelet transform (DWT for power measurement in smart meters. The most common way to implement DWT is the pyramid algorithm; however, this is not feasible for practical DWT computation because it requires either a log N cascaded filter or O (N word size memory storage for an input signal of the N-point. Both solutions are too expensive for practical applications of smart meters. It is proposed that the recursive pyramid algorithm is more suitable for smart meter implementation because it requires only word size storage of L × Log (N-L, where L is the length of filter. We also investigated the effect of varying different system parameters, such as the sampling rate, dc offset, phase offset, linearity error in current and voltage sensors, analog to digital converter resolution, and number of harmonics in a non-sinusoidal system, on the reactive energy measurement using DWT. The error analysis is depicted in the form of the absolute difference between the measured and the true value of the reactive energy.

  5. Measurement of the physics properties of gas-cooled fast reactors in the zero energy reactor PROTEUS and analysis of the results

    International Nuclear Information System (INIS)

    Richmond, R.

    1982-12-01

    The main aim of the fast reactor physics measurements carried out in the zero energy reactor PROTEUS was to check the performance of data sets and calculation methods used in the design of fast breeder reactors. This allowed the accuracy of the power reactor calculations to be determined and enabled an assessment to be made of whether this accuracy would be sufficient to allow the design, construction and licensing of the GCFR power reactor. In order to carry out the physics measurements an existing zero energy reactor was converted to a form in which a central fast reactor lattice was surrounded by thermal zones to drive the reactor critical. One of the most important measuring techniques used to check the performance of data sets and calculation methods was the determination of reaction rate ratios and, by using an appropriate range of nuclides, it was possible to obtain a detailed picture covering 70% of reactions taking place in the central part of the fast reactor zone and with an accuracy of +-1.5% in a typical ratio. A further technique used during the work on GCFR-PROTEUS was the measurement of neutron spectrum which was carried out in a wide range of environments and, in the later stages of the work, covered the energy range from 9 keV to 2.3 MeV. These measurements, in particular, indicated significant errors in the FGL4 scattering cross-sections. A third technique, which was developed to a high degree of accuracy, was the measurement of reactivity worths. This was used in measurements of the worths of small samples and also in the application of the null reactivity technique to determine k-infinity and hence the absorption cross-sections of reactor structural materials. (Auth.)

  6. Measurements of thermal and fast neutron fluxes at the TRIGA reactor

    International Nuclear Information System (INIS)

    Zerdin, F.; Grabovsek, Z.; Klinc, T.; Solinc, H.

    1966-01-01

    Gold foils were placed at different positions in the TRIGA reactor core and in the experimental devices. Absolute values of the thermal neutron flux at these positions were obtained by coincidence method. Preliminary fast neutron spectrum was measured by threshold detector and by 'Li 6 sandwich' detector. A short description of the applied method and obtained measurements results are included [sl

  7. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  8. Measurements of fuel temperature coefficient of reactivity on a commercial AGR

    International Nuclear Information System (INIS)

    Telford, A.; Bridge, M.J.

    1978-01-01

    Tests have been carried out on the commercial AGR at Hikley Point to determine the fuel temperature coefficient of reactivity, an important safety related parameter. Reactor neutron flux was measured during transients induced by movement of a bank of control rods from one steady position to another. An inverse kinetics analysis was applied to the measured flux to determine the change which occured in core reactivity as the fuel temperature changed. The variation of mean fuel temperature was deduced from the flux transient by means of a nine-plane thermal hydraulics representation of the AGR fuel channel. Results so far obtained confirm the predicted variation of fuel temperature coefficient with butn-up. (author)

  9. Reactivity in Rapidly Collected Hygiene and Toilet Spot Check Measurements: A Cautionary Note for Longitudinal Studies

    Science.gov (United States)

    Arnold, Benjamin F.; Khush, Ranjiv S.; Ramaswamy, Padmavathi; Rajkumar, Paramasivan; Durairaj, Natesan; Ramaprabha, Prabhakar; Balakrishnan, Kalpana; Colford Jr., John M.

    2015-01-01

    Discreet collection of spot check observations to measure household hygiene conditions is a common measurement technique in epidemiologic studies of hygiene in low-income countries. The objective of this study was to determine whether the collection of spot check observations in longitudinal studies could itself induce reactivity (i.e., change participant behavior). We analyzed data from a 12-month prospective cohort study in rural Tamil Nadu, India that was conducted in the absence of any hygiene or toilet promotion activities. Our data included hygiene and toilet spot checks from 10,427 household visits. We found substantial evidence of participant reactivity to spot check observations of hygiene practices that were easy to modify on short notice. For example, soap observed at the household's primary handwashing location increased from 49% at enrollment to 81% by the fourth visit and remained at or above 77% for the remainder of the study. PMID:25385856

  10. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... (ICC) and limits of agreement. RESULTS: Fifteen minutes of hyperoxia was accompanied by mean reductions in arterial and venous perfusion velocities of 14% and 16%, respectively (p = 0.0080; p = 0.0019), constriction of major arteries and veins by 5.5% and 8.2%, respectively (p ...). For perfusion velocities, short-term ICCs were 0.79-0.82 and long-term ICCs were 0.06-0.11. Intersession increases in blood glucose were associated with reductions in perfusion velocities (arterial p = 0.0067; venous p = 0.018). CONCLUSION: Oxygen reactivity testing supported that motion-contrast velocimetry...

  11. Application of the neutron noise technique for measurement of reactivity for subcritical reactor RA-4

    International Nuclear Information System (INIS)

    Orso, J; Marenzana, A

    2012-01-01

    Reactor core RA-4 is divided into two parts that come together to start reactor. The reactor with core separate has the largest subcritical condition, this condition is more secure and therefore the reactor shutdown. In this paper measurements are made of the decay constant of the neutron prompt ' P ', using the α-Rossi and α-Feynman methods to calculate the reactivity of the reactor core for different positions. Both techniques are compared and reactivity is obtained for several position of the reactor core using the α-Rossi technical which is obtained a function that gives the reactivity depending on the separation of the core length. Both techniques are verified using a no multiplicative system. Reactivity values for different position of the core obtained by α-Rossi technique are: $[0 cm] = (-11+/-1) dollar, $[3 cm] = (-7+/-1) dollar, $[3.5 cm] (-5.5+/-0.8) dollar, $[4.2 cm] = (-3.8+/-0.3) dollar y $[4.5] = (-3.0+/-0.1) dollar (author)

  12. Acetic acid recovery from fast pyrolysis oil. An exploratory study on liquid-liquid reactive extraction using aliphatic tertiary amines

    NARCIS (Netherlands)

    Mahfud, F. H.; van Geel, F. P.; Venderbosch, R. H.; Heeres, H. J.

    2008-01-01

    Flash pyrolysis oil or Bio-oil (BO), obtained by flash pyrolysis of lignocellulosic biomass, is very acidic in nature. The major component responsible for this acidity is acetic acid, present in levels up to 2-10 wt%. Here, we report an exploratory study on BO upgrading by reactive extraction of

  13. Current measurement method for characterization of fast switching power semiconductors with Silicon Steel Current Transformer

    DEFF Research Database (Denmark)

    Li, Helong; Beczkowski, Szymon; Munk-Nielsen, Stig

    2015-01-01

    , it compensates the mechanical size limitations of the Pearson current monitor. Finally, experimental studied are carried out with both discrete Silicon Carbide (SiC) MOSFET and high current (1000A) Silicon (Si) IGBT power modules. The experimental results validate the effectiveness of the proposed method.......This paper proposes a novel current measurement method with Silicon Steel Current Transformer (SSCT) for the characterization of fast switching power semiconductors. First, the existing current sensors for characterization of fast switching power semiconductors are experimentally evaluated...... regarding three essential qualities: high bandwidth, suitable physical size, and galvanic isolation. Then, the proposed current measurement method with SSCT is mathematically analyzed, which proves that the proposed method has the capability of measuring fast switching current. Simultaneously...

  14. Direct N2O5 reactivity measurements at a polluted coastal site

    Directory of Open Access Journals (Sweden)

    C. J. Gaston

    2012-03-01

    Full Text Available Direct measurements of N2O5 reactivity on ambient aerosol particles were made during September 2009 at the Scripps Institution of Oceanography (SIO Pier facility located in La Jolla, CA. N2O5 reactivity measurements were made using a custom flow reactor and the particle modulation technique alongside measurements of aerosol particle size distributions and non-refractory composition. The pseudo-first order rate coefficients derived from the particle modulation technique and the particle surface area concentrations were used to determine the population average N2O5 reaction probability, γ(N2O5, approximately every 50 min. Insufficient environmental controls within the instrumentation trailer led us to restrict our analysis primarily to nighttime measurements. Within this subset of data, γ(N2O5 ranged from γ(N2O5 are important, such as organic coatings or non-aqueous particles. The largest apparent driver of day-to-day variability in the measured γ(N2O5 at this site was the particle nitrate loading, as inferred from both the measured particle composition and the parameterizations. The relative change in measured γ(N2O5 as a function of particle nitrate loading appears to be consistent with expectations based on laboratory data, providing direct support for the atmospheric importance of the so-called "nitrate effect".

  15. Recent Fast Neutron Imaging Measurements with the Fieldable Nuclear Materials Identification System

    Energy Technology Data Exchange (ETDEWEB)

    Mullens, James Allen [ORNL; Mihalczo, John T [ORNL; Archer, Daniel E [ORNL; Thompson, Thad [ORNL; Britton Jr, Charles L [ORNL; Ezell, N Dianne Bull [ORNL; Ericson, Milton Nance [ORNL; Farquhar, Ethan [ORNL; Lind, Randall F [ORNL; Carter, Jake [ORNL

    2015-01-01

    This paper describes some recent fast neutron imaging measurements of the fieldable nuclear materials identification system (FNMIS) under development by the National Nuclear Security Administration (NNSA-NA-22) for possible future use in arms control and nonproliferation applications. The general configuration of FNMIS has been previously described, and a description of the application-specific integrated circuit (ASIC) electronics designed for FNMIS has been reported. This paper presents initial imaging measurements performed at ORNL with a Thermo Fisher API 120 DT generator and the fast-neutron imaging module of FNMIS.

  16. SXR Continuum Radiation Transmitted Through Metallic Filters: An Analytical Approach To Fast Electron Temperature Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Aparicio, L.; Tritz, K.; Kramer, T.; Stutman, D.; Finkentha, M.; Hill, K.; Bitter, M.

    2010-08-26

    A new set of analytic formulae describes the transmission of soft X-ray (SXR) continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler, Rev. Sci. Instrum., 20, 599, (1999)]. The new analytic formulae can improve the interpretation of the experimental results and thus contribute in obtaining fast teperature measurements in between intermittent Thomson Scattering data.

  17. Preliminary research on measuring grease in petroleum pipeline using fast neutron transmission method

    International Nuclear Information System (INIS)

    Liu Qingwei; Liu Shengkang; Zhang Zhiping; Ding Xiaoping

    2006-01-01

    The principle, experiment and conclusion on the grease stain measurement using fast neutron are reported. The experiment equipment consist of 241 Am-Be fast neutron source, ZnS detector and BH1224 multichannel spectrometer. Paraffin is used instead of real grease stain. Steel plates are used instead of pipeline. The results of the experiment indicate that there is a good linearship between the logarithm of the reciprocal of the neutron transmissivity and the paraffin thickness. The measuring accuracy of the paraffin thickness is 0.6 mm in this experiment. (authors)

  18. Further development of the Dynamic Control Assemblies Worth Measurement Method for Advanced Reactivity Computers

    International Nuclear Information System (INIS)

    Petenyi, V.; Strmensky, C.; Jagrik, J.; Minarcin, M.; Sarvaic, I.

    2005-01-01

    The dynamic control assemblies worth measurement technique is a quick method for validation of predicted control assemblies worth. The dynamic control assemblies worth measurement utilize space-time corrections for the measured out of core ionization chamber readings calculated by DYN 3D computer code. The space-time correction arising from the prompt neutron density redistribution in the measured ionization chamber reading can be directly applied in the advanced reactivity computer. The second correction concerning the difference of spatial distribution of delayed neutrons can be calculated by simulation the measurement procedure by dynamic version of the DYN 3D code. In the paper some results of dynamic control assemblies worth measurement applied for NPP Mochovce are presented (Authors)

  19. Measurement and evaluation of fast neutron flux of CT and OR5 irradiation hole in HANARO

    International Nuclear Information System (INIS)

    Yang, Seong Woo; Choo, Kee Nam; Lee, Seung-Kyu; Kim, Yong Kyun

    2012-01-01

    The irradiation test has been conducted to evaluate the irradiation performance of many materials by a material capsule at HANARO. Since the fast neutron fluence above 1 MeV is important for the irradiation test of material, it must be measured and evaluated exactly at each irradiation hole. Therefore, a fast neutron flux was measured and evaluated by a 09M-02K capsule irradiated in an OR5 irradiation hole and a 10M-01K capsule irradiated in a CT irradiation hole. Fe, Ni, and Ti wires as the fluence monitor were used for the detection of fast neutron flux. Before the irradiation test, the neutron flux and spectrum was calculated for each irradiation hole using an MCNP code. After the irradiation test, the activity of the fluence monitor was measured by an HPGe detector and the reaction rate was calculated. For the OR5 irradiation hole, the radial difference of the fast neutron flux was observed from a calculated data due to the OR5 irradiation hole being located outside the core. Furthermore, a control absorber rod was withdrawn from the core as the increase of the irradiation time at the same irradiation cycle, so the distribution of neutron flux was changed from the beginning to the end of the cycle. These effects were considered to evaluate the fast neutron flux. Neutron spectrums of the CT and OR5 irradiation hole were adjusted by the measured data. The fluxes of a fast neutron above 1 MeV were compared with calculated and measured value. Although the maximum difference was shown at 18.48%, most of the results showed good agreement. (author)

  20. First fast-ion D-alpha (FIDA) measurements and simulations on C-2U

    Energy Technology Data Exchange (ETDEWEB)

    Bolte, N. G., E-mail: nbolte@TriAlphaEnergy.com; Gupta, D.; Onofri, M.; Dettrick, S.; Granstedt, E. M.; Petrov, P. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States); Stagner, L. [University of California, Irvine, Irvine, California 92697 (United States)

    2016-11-15

    The first measurements of fast-ion D-alpha (FIDA) radiation have been acquired on C-2U, Tri Alpha Energy’s advanced, beam-driven field-reversed configuration (FRC). These measurements are also forward modeled by FIDASIM. This is the first measurement and simulation of FIDA carried out on an FRC topology. FIDA measurements are made of Doppler-shifted Balmer-alpha light from neutralized fast ions using a bandpass filter and photomultiplier tube. One adjustable line-of-sight measured signals at eight locations and eight times during the FRC lifetime over 26 discharges. Filtered signals include only the highest energy ions (>6 keV) and share some salient features with the FIDASIM result. Highly Doppler-shifted beam radiation is also measured with a high-speed camera and is spatially well-correlated with FIDASIM.

  1. Reactivation of slow-moving landslides by earthquakes, kinematics measurements and mechanical implications

    Science.gov (United States)

    Lacroix, Pascal; Perfettini, Hugo; Berthier, Etienne; Taipe, Edu; Guillier, Bertrand

    2015-04-01

    Major earthquakes in mountainous areas often trigger landslides. The impact of earthquakes on slow-moving landslides is however not well constrained due to few co-seismic measurements of landslide motion. We document the first time-series of a landslide reactivation by an earthquake (Mw6.0, distance 20 km), using continuous GPS measurements over the Maca landslide (Peru). Our survey shows a coseismic response of the landslide of about 2 cm, followed by a relaxation period of 5 weeks during which postseismic slip is three times greater than the coseismic displacement itself. Our results confirm the coseismic activation of landslides and provide the first observation of a post seismic displacement. Finally, a multi-temporal survey using images from the very high resolution Pléiades optical satellite, allowed us to detect 9 active slow-moving landslides over the whole valley. Their pattern of motion show they have been reactivated by the same earthquake. We analyze this small but comprehensive database of landslides reactivated by the earthquake. We find that the landslide motion due to the earthquake is function of the shaking intensity, suggesting a friction at the basal interface dependent on the earthquake solicitation. These various observations are consistent with a mechanical model where slip on the landslide basal interface is governed by rate and state friction, analogous to the mechanics of creeping tectonic faults.

  2. Measurements of effective delayed neutron fraction in a fast neutron reactor using the perturbation method

    Science.gov (United States)

    Zhou, Hao-Jun; Yin, Yan-Peng; Fan, Xiao-Qiang; Li, Zheng-Hong; Pu, Yi-Kang

    2016-06-01

    A perturbation method is proposed to obtain the effective delayed neutron fraction β eff of a cylindrical highly enriched uranium reactor. Based on reactivity measurements with and without a sample at a specified position using the positive period technique, the reactor reactivity perturbation Δρ of the sample in β eff units is measured. Simulations of the perturbation experiments are performed using the MCNP program. The PERT card is used to provide the difference dk of effective neutron multiplication factors with and without the sample inside the reactor. Based on the relationship between the effective multiplication factor and the reactivity, the equation β eff = dk/Δρ is derived. In this paper, the reactivity perturbations of 13 metal samples at the designable position of the reactor are measured and calculated. The average β eff value of the reactor is given as 0.00645, and the standard uncertainty is 3.0%. Additionally, the perturbation experiments for β eff can be used to evaluate the reliabilities of the delayed neutron parameters. This work shows that the delayed neutron data of 235U and 238U from G.R. Keepin’s publication are more reliable than those from ENDF-B6.0, ENDF-B7.0, JENDL3.3 and CENDL2.2. Supported by Foundation of Key Laboratory of Neutron Physics, China Academy of Engineering Physics (2012AA01, 2014AA01), National Natural Science Foundation (11375158, 91326104)

  3. Bayesian Integrated Data Analysis of Fast-Ion Measurements by Velocity-Space Tomography

    DEFF Research Database (Denmark)

    Salewski, M.; Nocente, M.; Jacobsen, A.S.

    2018-01-01

    Bayesian integrated data analysis combines measurements from different diagnostics to jointly measure plasma parameters of interest such as temperatures, densities, and drift velocities. Integrated data analysis of fast-ion measurements has long been hampered by the complexity of the strongly non...... framework. The implementation for different types of diagnostics as well as the uncertainties are discussed, and we highlight the importance of integrated data analysis of all available detectors....

  4. Strategies for measuring flows of reactive nitrogen at the landscape scale

    DEFF Research Database (Denmark)

    Theobald, Mark; Boegh, Eva; Cellier, Pierre

    2011-01-01

    Within a rural landscape there are flows of reactive nitrogen (Nr) through and between the soil, vegetation, atmosphere and hydrological systems as well as transfer as a result of agricultural activities. Measurements of these flows and transfers have generally been limited to individual media (e.......g., hydrological flows) or the interface between two media (e.g., exchange between the soil and the atmosphere). However, the study of flows of Nr at the landscape scale requires a more integrated approach that combines measurement techniques to quantify the flows from one medium to the next. This paper discusses...

  5. Self-reported trait mindfulness and affective reactivity: a motivational approach using multiple psychophysiological measures.

    Directory of Open Access Journals (Sweden)

    Danielle Cosme

    Full Text Available As a form of attention, mindfulness is qualitatively receptive and non-reactive, and is thought to facilitate adaptive emotional responding. One suggested mechanism is that mindfulness facilitates disengagement from an affective stimulus and thereby decreases affective reactivity. However, mindfulness has been conceptualized as a state, intervention, and trait. Because evidence is mixed as to whether self-reported trait mindfulness decreases affective reactivity, we used a multi-method approach to study the relationship between individual differences in self-reported trait mindfulness and electrocortical, electrodermal, electromyographic, and self-reported responses to emotional pictures. Specifically, while participants (N = 51 passively viewed pleasant, neutral, and unpleasant IAPS pictures, we recorded high-density (128 channels electrocortical, electrodermal, and electromyographic data to the pictures as well as to acoustic startle probes presented during the pictures. Afterwards, participants rated their subjective valence and arousal while viewing the pictures again. If trait mindfulness spontaneously reduces general emotional reactivity, then for individuals reporting high rather than low mindfulness, response differences between emotional and neutral pictures would show relatively decreased early posterior negativity (EPN and late positive potential (LPP amplitudes, decreased skin conductance responses, and decreased subjective ratings for valence and arousal. High mindfulness would also be associated with decreased emotional modulation of startle eyeblink and P3 amplitudes. Although results showed clear effects of emotion on the dependent measures, in general, mindfulness did not moderate these effects. For most measures, effect sizes were small with rather narrow confidence intervals. These data do not support the hypothesis that individual differences in self-reported trait mindfulness are related to spontaneous emotional responses

  6. Self-Reported Trait Mindfulness and Affective Reactivity: A Motivational Approach Using Multiple Psychophysiological Measures

    Science.gov (United States)

    Cosme, Danielle; Wiens, Stefan

    2015-01-01

    As a form of attention, mindfulness is qualitatively receptive and non-reactive, and is thought to facilitate adaptive emotional responding. One suggested mechanism is that mindfulness facilitates disengagement from an affective stimulus and thereby decreases affective reactivity. However, mindfulness has been conceptualized as a state, intervention, and trait. Because evidence is mixed as to whether self-reported trait mindfulness decreases affective reactivity, we used a multi-method approach to study the relationship between individual differences in self-reported trait mindfulness and electrocortical, electrodermal, electromyographic, and self-reported responses to emotional pictures. Specifically, while participants (N = 51) passively viewed pleasant, neutral, and unpleasant IAPS pictures, we recorded high-density (128 channels) electrocortical, electrodermal, and electromyographic data to the pictures as well as to acoustic startle probes presented during the pictures. Afterwards, participants rated their subjective valence and arousal while viewing the pictures again. If trait mindfulness spontaneously reduces general emotional reactivity, then for individuals reporting high rather than low mindfulness, response differences between emotional and neutral pictures would show relatively decreased early posterior negativity (EPN) and late positive potential (LPP) amplitudes, decreased skin conductance responses, and decreased subjective ratings for valence and arousal. High mindfulness would also be associated with decreased emotional modulation of startle eyeblink and P3 amplitudes. Although results showed clear effects of emotion on the dependent measures, in general, mindfulness did not moderate these effects. For most measures, effect sizes were small with rather narrow confidence intervals. These data do not support the hypothesis that individual differences in self-reported trait mindfulness are related to spontaneous emotional responses during picture

  7. Development of fast measurements of concentration of NORM U-238 by HPGe

    International Nuclear Information System (INIS)

    Cha, Seokki; Kim, Geehyun; Kim, Siu

    2017-01-01

    Naturally Occureed Radioactive Material (NORM) generated from the origin of earth can be found all around us and even people who are not engaged in the work related to radiation have been exposed to unnecessary radiation. This NORM has a potential risk provided that is concentrated or transformed by artificial activities. Likewise, a development of fast measruement method of NORM is emerging to prevent the radiation exposure of the general public and person engaged in the work related to the type of business related thereto who uses the material in which NORM is concentrated or transfromed. Based on such a background, many of countries have tried to manage NORM and carried out regulatory legislation. To effienctly manage NORM, there is need for developing new measurement to quickly and accurately analyze the nuclide and concentration. In this study, development of the fast and reliable measurement was carried out. In addition to confirming the reliability of the fast measurement, we have obtained results that can suggest the possibility of developing another fast measurement. Therefore, as a follow-up, it is possible to develop another fast analytical measurement afterwards. The results of this study will be very useful for the regulatory system to manage NORM. In this study, a review of two indirect measurement methods of NORM U-238 that has used HPGe on the basis of the equilibrium theory of relationships of mother and daughter nuclide at decay-chain of NORM U-238 has been carried out. For comparative study(in order to know reliabily), direct measurement that makes use of alpha spectrometer with complicated pre-processing process was implemented.

  8. Estimation of Mechanical Vibrations of the LHC Fast Magnetic Measurement System

    CERN Document Server

    Brooks, N R; García-Pérez, J; Dunkel, O; Walckiers, L

    2008-01-01

    Current installation of the Large Hadron Collider (LHC) particle accelerator at CERN has required the use of a harmonic coil magnetic measurement system to quantify the magnetic field harmonic quality of the superconducting, twin aperture LHC dipoles. Current and future needs for measuring fast changing magnetic fields necessitates the use of a rotating unit (RU) and associated electronics to drive this long shaft with increased speed and measurement bandwidth. Therefore, the Fast Magnetic Measurement Equipment (FAME) project has been launched to deliver such a system. A primary obstacle to achieving the goals of the FAME project is the possibility of amplifying mechanical vibrations due to increased speeds. This paper presents the methodology and results of an experimental investigation conducted to estimate mechanical vibrations of the long shaft within a cold-bore mounted anti-cryostat at various rotational speeds using magnetic measurements.

  9. Measuring Sensory Reactivity in Autism Spectrum Disorder: Application and Simplification of a Clinician-Administered Sensory Observation Scale

    Science.gov (United States)

    Tavassoli, Teresa; Bellesheim, Katherine; Siper, Paige M.; Wang, A. Ting; Halpern, Danielle; Gorenstein, Michelle; Grodberg, David; Kolevzon, Alexander; Buxbaum, Joseph D.

    2016-01-01

    Sensory reactivity is a new DSM-5 criterion for autism spectrum disorder (ASD). The current study aims to validate a clinician-administered sensory observation in ASD, the Sensory Processing Scale Assessment (SPS). The SPS and the Short Sensory Profile (SSP) parent-report were used to measure sensory reactivity in children with ASD (n = 35) and…

  10. Fast turn-on of an NMOS ESD protection transistor: measurements and simulations

    NARCIS (Netherlands)

    Luchies, J.R.M.; Luchies, J.R.M.; de Kort, C.G.M.; Verweij, J.F.; Verweij, J.F.

    1995-01-01

    The transient turn-on of the parasitic bipolar transistor of an NMOS transistor was studied. The voltages appearing at internal nodes of protection and functional circuit after application of 350 ps rise-time pulses have been measured using electro-optic sampling. For very fast transients the

  11. Fast RF-CV characterization through high-speed 1-port S-parameter measurements

    NARCIS (Netherlands)

    Herfst, R.W.; Steeneken, P.G.; Tiggelman, M.P.J.; Stulemeijer, J.; Schmitz, Jurriaan

    2010-01-01

    We present a novel method to measure the capacitance-voltage relation of an electronic device. The approach is accurate, very fast, and cost-effective compared to the existing off-the-shelf solutions. Capacitances are determined using a single-frequency 1-port S-parameter setup constructed from

  12. Digital reactivity meter

    International Nuclear Information System (INIS)

    Copie, M.; Valantic, B.

    1978-01-01

    Digital reactivity meters (DRM) are mostly used as measuring instruments, e.g. for calibration of control rods, and there are only a few cases of their incorporation into the control systems of the reactors. To move in this direction there is more development work needed. First of all, fast algorithms are needed for inverse kinetics equations to relieve the computer for more important tasks of reactor model solving in real time. The next problem, currently under investigation, is the incorporation of the reactor thermal-hydraulic model into the DRM so that it can be used in the power range. Such an extension of DHM allows presentation not only of the instantaneous reactivity of the system, but also the inserted reactivity can be estimated from the temperature reactivity feed-backs. One of the applications of this concept is the anomalous digital reactivity monitor (ADRN) as part of the reactor protection system. As a solution of the first problem, a fast algorithm for solving the inverse kinetics equations has been implemented in the off-line program RODCAL on CDC 1700 computer and tested for its accuracy by performing different control rod calibrations on the reactor TRIGA

  13. Application of the dynamic control rod reactivity measurement method to Korea standard nuclear power plants

    International Nuclear Information System (INIS)

    Lee, E. K.; Shin, H. C.; Bae, S. M.; Lee, Y. G.

    2004-01-01

    To measure and validate the worth of control bank or shutdown bank, the dynamic control rod reactivity measurement (DCRM) technique has been developed and applied to six cases of Low Power Physics Tests of PWRs including Korea Standard Nuclear Power plant (KSNP) based on the CE System 80 NSSS. Through the DORT results for each two ex-ore detector response and the three dimensional core transient simulations for rod movements, the key parameters of DCRM method are determined to implement into the Direct Digital Reactivity Computer System (DDRCS). A total of 9 bank worths of two KSNP plants were measured to compare with the worths of the conventional rod worth measurement method. The results show that the average error of DCRM method is nearly the same as the conventional Rod Swap and Boron Dilution Method but lower standard deviation. It takes about twenty minutes from the beginning of rod movement to final estimation of the integral static worth of a control bank. (authors)

  14. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering

    International Nuclear Information System (INIS)

    Bindslev, H; Nielsen, S K; Porte, L; Hoekzema, J A; Korsholm, S B; Meo, F; Michelsen, P K; Michelsen, S; Oosterbeek, J W; Tsakadze, E L; Westerhof, E; Woskov, P

    2007-01-01

    The dynamics of fast ion populations in the TEXTOR tokamak are measured by collective Thomson scattering of millimetre wave radiation generated by a gyrotron operated at 110 GHz and 100-150 kW. Temporal evolution of the energetic ion velocity distribution at switch on of neutral beam injection (NBI) and the slowdown after switch off of NBI are measured. The turn on phase of the NBI has, furthermore, been measured in plasmas with a range of electron densities and temperatures. All of these measurements are shown to be in good agreement with simple Fokker-Planck modelling. Bulk ion rotation velocity is also measured

  15. Fast automatic system for measurements of beam parameters of the MMF linac

    International Nuclear Information System (INIS)

    Reinhardt-Nickulin, P.; Bragin, S.; Ilinsky, N.; Senichev, Yu.

    1992-01-01

    Fast transverse beam profile and current monitoring systems have been tested at the Linear Accelerator of Moscow Meson Factory. The signals for each system are derived from multiwire secondary emission chamber and beam current transformer. Each beam pulse is digitized by fast ADC's. There are two modes for systems. First one is for detailed beam adjustment and second one is for normal 100 Hz rate of the MMF Linac. Essential features of the hardware, software, data acquisition, measurement accuracy and beam results are presented. (author)

  16. Fast flux measurements by means of threshold detectors on the reactor 'Melusine'

    International Nuclear Information System (INIS)

    Leger, P.; Sautiez, B.

    1959-01-01

    Using existing data on the (n,p) and (n,α) threshold reactions we have carried out fast flux measurements on the swimming pool type reactor 'Melusine'. Four common elements: P, S, Mg, Al were chosen because from the point of view of fast spectrum analysis they represent a fairly good energy range from 2.4 MeV to 8 MeV. The fission flux value found in the central element at a power of 1 MW is 1.4 x 10 13 n/cm 2 /s ± 0.14. (author) [fr

  17. A flexible, on-line magnetic spectrometer for ultra-intense laser produced fast electron measurement

    Science.gov (United States)

    Ge, Xulei; Yuan, Xiaohui; Yang, Su; Deng, Yanqing; Wei, Wenqing; Fang, Yuan; Gao, Jian; Liu, Feng; Chen, Min; Zhao, Li; Ma, Yanyun; Sheng, Zhengming; Zhang, Jie

    2018-04-01

    We have developed an on-line magnetic spectrometer to measure energy distributions of fast electrons generated from ultra-intense laser-solid interactions. The spectrometer consists of a sheet of plastic scintillator, a bundle of non-scintillating plastic fibers, and an sCMOS camera recording system. The design advantages include on-line capturing ability, versatility of detection arrangement, and resistance to harsh in-chamber environment. The validity of the instrument was tested experimentally. This spectrometer can be applied to the characterization of fast electron source for understanding fundamental laser-plasma interaction physics and to the optimization of high-repetition-rate laser-driven applications.

  18. Spent fuel measurements. passive neutron albedo reactivity (PNAR) and photon signatures

    Energy Technology Data Exchange (ETDEWEB)

    Eigenbrodt, Julia [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-29

    The International Atomic Energy Agency’s (IAEA) safeguards technical objective is the timely detection of a diversion of a significant quantity of nuclear material from peaceful activities to the manufacture of nuclear weapons or of other nuclear explosive devices or for purposes unknown, and deterrence of such diversion by the risk of early detection. An important IAEA task towards meeting this objective is the ability to accurately and reliably measure spent nuclear fuel (SNF) to verify reactor operating parameters and verify that the fuel has not been removed from reactors or SNF storage facilities. This dissertation analyzes a method to improve the state-of-the-art of nuclear material safeguards measurements using two combined measurement techniques: passive neutron albedo reactivity (PNAR) and passive spectral photon measurements.

  19. Development of electronic system for reactivity measurement and reactor noise analysis

    International Nuclear Information System (INIS)

    Strohl, Claude Emile; Soares, Adalberto Jose

    1996-01-01

    In nuclear power reactors, the neutron detector signal is dependent of the number of fissions and the reactor power level. The detector signal can be divided into two components; a DC component, proportional to the average value and an AC component, which is the fluctuating part superimposed to the DC component. The analysis of the fluctuating part of the signal is called noise analysis and allow us to investigate phenomena occurring within the reactor vessel, such as vibration of fuels elements and coolant density, temperature, pressure and flow changes. On the other hand, the measure of the static DC part allow us to measure the local power density. This paper describes the development of a personal computer based signal conditioning card that, together with a personal computer commercial data acquisition card, can be used for noise analysis measurements and reactivity measurements of signals coming from ionization chambers or SPD's. (author)

  20. Influence of Fasting Status and Sample Preparation on Metabolic Biomarker Measurements in Postmenopausal Women.

    Science.gov (United States)

    Murphy, Neil; Falk, Roni T; Messinger, Diana B; Pollak, Michael; Xue, Xiaonan; Lin, Juan; Sgueglia, Robin; Strickler, Howard D; Gaudet, Mia M; Gunter, Marc J

    2016-01-01

    Epidemiologic data linking metabolic markers-such as insulin, insulin-like growth factors (IGFs)-and adipose tissue-derived factors with cancer are inconsistent. Between-study differences in blood collection protocols, in particular participant's fasting status, may influence measurements. We investigated the impact of fasting status and blood sample processing time on components of the insulin/IGF axis and in adipokines in a controlled feeding study of 45 healthy postmenopausal-women aged 50-75 years. Fasting blood samples were drawn (T0), after which subjects ate a standardized breakfast; subsequent blood draws were made at 1 hour (T1), 3 hours (T3), and 6 hours (T6) after breakfast. Serum samples were assayed for insulin, C-peptide, total- and free-IGF-I, IGF-binding protein [BP]-1 and -3, total and high molecular weight (HMW)-adiponectin, retinol binding protein-4, plasminogen activator inhibitor (PAI)-1, and resistin. Insulin and C-peptide levels followed similar postprandial trajectories; intra-class correlation coefficients [ICC] for insulin = 0.75, (95%CI:0.64-0.97) and C-peptide (ICC = 0.66, 95%CI:0.54-0.77) were similarly correlated in fasting (Spearman correlation, r = 0.78, 95%CI:0.64-0.88) and postprandial states (T1, r = 0.77 (95%CI: 0.62-0.87); T3,r = 0.78 (95%CI: 0.63-0.87); T6,r = 0.77 (95%CI: 0.61-0.87)). Free-IGF-I and IGFBP-1 levels were also affected by fasting status, whereas total-IGF-I and IGFBP-3 levels remained unchanged. Levels of adipokines were largely insensitive to fasting status and blood sample processing delays. Several components of the insulin/IGF axis were significantly impacted by fasting state and in particular, C-peptide levels were substantially altered postprandially and in a similar manner to insulin.

  1. Oxygen optodes as fast sensors for eddy correlation measurements in aquatic systems

    DEFF Research Database (Denmark)

    Chipman, Lindsay; Huettel, Markus; Berg, Peter

    2012-01-01

    The aquatic eddy-correlation technique can be used to noninvasively determine the oxygen exchange across the sediment-water interface by analyzing the covariance of vertical flow velocity and oxygen concentration in a small measuring volume above the sea bed. The method requires fast sensors...... that combine the advantages of noninvasive measurements and integration of fluxes over a large footprint area, using a relatively rugged and less expensive sensor....

  2. Training in the fasted state facilitates re-activation of eEF2 activity during recovery from endurance exercise

    OpenAIRE

    Van Proeyen, Karen; De Bock, Katrien; Hespel, Peter

    2011-01-01

    Nutrition is an important co-factor in exercise-induced training adaptations in muscle. We compared the effect of 6 weeks endurance training (3 days/week, 1-2 h at 75% VO(2peak)) in either the fasted state (F; n = 10) or in the high carbohydrate state (CHO, n = 10), on Ca(2+)-dependent intramyocellular signalling in young male volunteers. Subjects in CHO received a carbohydrate-rich breakfast before each training session, as well as ingested carbohydrates during exercise. Before (pretest) and...

  3. Observation of skin thermal inertia distribution during reactive hyperaemia using a single-hood measurement system.

    Science.gov (United States)

    Hassan, M; Togawa, T

    2001-02-01

    An attempt was made to image the thermal inertia (defined as the square root of the product of thermal conductivity, specific heat and density) of the skin to observe the distribution of blood in the skin during post-occlusive reactive hyperaemia in normal healthy volunteers. The method was based on the ability to calculate thermal inertia by successive thermographic measurements of the skin after stepwise change in ambient radiation temperature surrounding the skin area. The stepwise change was achieved within 0.1 s through a single hood. Experimentation on the undisturbed volar forearm of normal subjects at the same site showed that the measurements thus achieved were reproducible. The thermal inertia values of forearm skin in normal subjects were scattered throughout the range 1.1 x 10(3) to 1.7 x 10(3) W s(1/2) m(-2) K(-1). Experiments on forearm skin subjected to arterial cuff occlusion indicated that thermal inertia can be detected at a low level of blood perfusion. A linear relationship was observed between thermal inertia and blood perfusion measured by laser Doppler imager before and during blood flow occlusion. During reactive hyperaemia, the thermal inertia image exhibited a non-uniform island-shaped pattern of distribution over the forearm, suggesting that, after release from occlusion, recovery of blood flow is non-uniform.

  4. Effect of rosuvastatin on fasting and postprandial endothelial biomarker levels and microvascular reactivity in patients with type 2 diabetes and dyslipidemia: a preliminary report.

    Science.gov (United States)

    Kim, Kyoung Min; Jung, Kyong Yeun; Yun, Han Mi; Lee, Seo Young; Oh, Tae Jung; Jang, Hak Chul; Lim, Soo

    2017-11-09

    The cardiovascular benefits of statins have been proven, but their effect on circulation in small vessels has not been examined fully. We investigated the effect of 20 mg rosuvastatin on biomarkers, including paraoxonase-1 (PON-1) and asymmetric dimethylarginine (ADMA), and on microvascular reactivity. We enrolled 20 dyslipidemic patients with type 2 diabetes and 20 age- and body mass index (BMI)-matched healthy controls. Rosuvastatin (20 mg/day) was given to the patient group for 12 weeks. Biochemical parameters, including PON-1 and ADMA, were compared between the patient and control groups, and before and after rosuvastatin treatment in the patient group. Fasting and 2 h postprandial levels of PON-1 and ADMA after mixed-meal challenge were also compared. Microvascular reactivity in a peripheral artery was examined using laser Doppler flowmetry. The respective mean ± standard deviation of age and BMI were 50.1 ± 3.8 year and 25.8 ± 3.7 kg/m 2 in the patients and 50.2 ± 3.2 year and 25.4 ± 3.4 kg/m 2 in the controls. The patient group had worse profiles of cardiometabolic biomarkers, including PON-1 and ADMA, than the controls. In the patients treated with 20 mg rosuvastatin, low-density lipoprotein (LDL)-cholesterol decreased from 147.2 ± 26.5 to 68.3 ± 24.5 mg/dL and high-density lipoprotein (HDL)-cholesterol increased from 42.4 ± 5.2 to 44.7 ± 6.2 mg/dL (both P fasting and 2 h postprandial levels of PON-1 increased and those of ADMA decreased after treatment with rosuvastatin for 12 weeks. The changes in postprandial levels of both biomarkers were greater than those after fasting. Microcirculation assessed as reactive hyperemia in the patients after an ischemic challenge increased significantly from 335.3 ± 123.4 to 402.7 ± 133.4% after rosuvastatin treatment. The postprandial changes in the biomarkers were significantly associated with improvement of microvascular reactivity. Rosuvastatin treatment for 12

  5. Strong pinning in very fast grown reactive co-evaporated GdBa2Cu3O7 coated conductors

    Directory of Open Access Journals (Sweden)

    J. L. MacManus-Driscoll

    2014-08-01

    Full Text Available We report on compositional tuning to create excellent field-performance of Jc in “self-doped,” GdBa2Cu3O7−y (GdBCO coated conductors grown by ultrafast reactive co-evaporation. In order to give excess liquid and Gd2O3, the overall compositions were all Ba-poor and Cu-rich compared to GdBCO. The precise composition was found to be critical to the current carrying performance. The most copper-rich composition had an optimum self-field Jc of 3.2 MA cm−2. A more Gd-rich composition had the best in-field performance because of the formation of low coherence, splayed Gd2O3 nanoparticles, giving Jc (77 K, 1 T of over 1 MA cm−2 and Jc (77 K, 5 T of over 0.1 MA cm−2.

  6. Development of mid-frequency AC reactive magnetron sputtering for fast deposition of Y2O3 buffer layers

    Science.gov (United States)

    Xiong, Jie; Xia, Yudong; Xue, Yan; Zhang, Fei; Guo, Pei; Zhao, Xiaohui; Tao, Bowan

    2014-02-01

    A reel-to-reel magnetron sputtering system with mid-frequency alternating current (AC) power supply was used to deposit double-sided Y2O3 seed layer on biaxially textured Ni-5 at.%W tape for YBa2Cu3O7-δ coated conductors. A reactive sputtering process was carried out using two opposite symmetrical sputtering guns with metallic yttrium targets and water vapor for oxidizing the sputtered metallic atoms. The voltage control mode of the power supply was used and the influence of the cathode voltage and ArH2 pressure were systematically investigated. Subsequently yttrium-stabilized zirconia (YSZ) barrier and CeO2 cap layers were deposited on the Y2O3 buffered substrates in sequence, indicating high quality and uniform double-sided structure and surface morphology of such the architecture.

  7. Spectroscopic Measurements of the Ion Velocity Distribution at the Base of the Fast Solar Wind

    Science.gov (United States)

    Jeffrey, Natasha L. S.; Hahn, Michael; Savin, Daniel W.; Fletcher, Lyndsay

    2018-03-01

    In situ measurements of the fast solar wind reveal non-thermal distributions of electrons, protons, and minor ions extending from 0.3 au to the heliopause. The physical mechanisms responsible for these non-thermal properties and the location where these properties originate remain open questions. Here, we present spectroscopic evidence, from extreme ultraviolet spectroscopy, that the velocity distribution functions (VDFs) of minor ions are already non-Gaussian at the base of the fast solar wind in a coronal hole, at altitudes of thermal equilibrium, (b) fluid motions such as non-Gaussian turbulent fluctuations or non-uniform wave motions, or (c) some combination of both. These observations provide important empirical constraints for the source region of the fast solar wind and for the theoretical models of the different acceleration, heating, and energy deposition processes therein. To the best of our knowledge, this is the first time that the ion VDF in the fast solar wind has been probed so close to its source region. The findings are also a timely precursor to the upcoming 2018 launch of the Parker Solar Probe, which will provide the closest in situ measurements of the solar wind at approximately 0.04 au (8.5 solar radii).

  8. Measurements of the fuel temperature coefficient of reactivity at Hinkley Point 'B': 1981

    International Nuclear Information System (INIS)

    George, T.A.

    1982-03-01

    Measurements of the fuel temperature coefficient of reactivity made at Hinkley Point 'B' AGR in 1981 are described. These measurements follow earlier tests reported in e.g. RD/B/N4846 and are part of a series of measurements designed to support theoretical estimates of the change of fuel temperature coefficient as a function of core irradiation. Low and high power measurements were made at a mean core irradiation of 1170GWD. As previously, the measurements at both power levels show agreement with theoretical predictions to within the estimated experimental errors. Recent measurements (mean core irradiation >500GWD) show evidence of a small systematic difference between measured and theoretical values with the experimental values being approximately equal to 0.1mN/ 0 C more positive than the theoretical ones. The measured value of αsub(U) at high power was -0.64+-0.10mN/ 0 C and the low power value, corrected theoretically to normal operating conditions, was also -0.64+-0.10mN/ 0 C. (author)

  9. RMR. A new portable Reactivity Measuring System installed at NPP Paks

    International Nuclear Information System (INIS)

    Czibok, T.; Horvath, C.; Bara, P.; Dezsoe, Z.; Laz, J.; Vegh, J.; Pos, I.

    2003-01-01

    The Hungarian Paks NPP is conducting a two year project for upgrading the reactivity measuring system applied during reactor startup experiments. The NPP has decided to replace almost all components of the previous system, only ionisation chambers remain unaltered. Devices for measuring neutron flux by means of ionisation chambers, for data acquisition and for measurement evaluation were completely renewed: new hardware-software components were introduced. Autonomous, high-precision current measuring systems (picoampere meters) are applied at each reactor unit, the converted picoampere signals are handled by a portable processing unit. The portable unit - based on a notebook PC - handles measured signals by using a high-precision A/D converter card, the scan time is 0.10 sec. In addition to handling three ionisation chamber signals the portable unit collects control rod position measurements through a serial line. The portable unit is able to receive additional measured data (e.g. core inlet temperature and boron concentration) from the process computer via local area network. Archiving of all measured and calculated data is performed in a redundant manner: data are stored locally and in the process computer, as well. The new system applies an accurate on-line reactivity calculation algorithm based on the point-kinetic model with 6 delayed neutron groups. Input data (effective delayed neutron fraction and other delayed neutron parameters) to the on-line calculation are taken from the off-line core design calculation. Detailed evaluation and analysis of startup measurements can be performed also on the portable unit. The user interface of the system is tailored to support various startup measurement tasks effectively: measured and calculated data are displayed on trends and on dedicated pictures. A user-friendly trending and listing graphic tool facilitates visualisation of archived data. The paper describes the architecture, data acquisition modules, algorithms and

  10. Reactivity of dogs' brain oscillations to visual stimuli measured with non-invasive electroencephalography.

    Directory of Open Access Journals (Sweden)

    Miiamaaria V Kujala

    Full Text Available Studying cognition of domestic dogs has gone through a renaissance within the last decades. However, although the behavioral studies of dogs are beginning to be common in the field of animal cognition, the neural events underlying cognition remain unknown. Here, we employed a non-invasive electroencephalography, with adhesive electrodes attached to the top of the skin, to measure brain activity of from 8 domestic dogs (Canis familiaris while they stayed still to observe photos of dog and human faces. Spontaneous oscillatory activity of the dogs, peaking in the sensors over the parieto-occipital cortex, was suppressed statistically significantly during visual task compared with resting activity at the frequency of 15-30 Hz. Moreover, a stimulus-induced low-frequency (~2-6 Hz suppression locked to the stimulus onset was evident at the frontal sensors, possibly reflecting a motor rhythm guiding the exploratory eye movements. The results suggest task-related reactivity of the macroscopic oscillatory activity in the dog brain. To our knowledge, the study is the first to reveal non-invasively measured reactivity of brain electrophysiological oscillations in healthy dogs, and it has been based purely on positive operant conditional training, without the need for movement restriction or medication.

  11. On-line fast flux measurements in the BR2 reactor

    International Nuclear Information System (INIS)

    Vermeeren, L.

    2009-01-01

    Since 2001, CEA-Cadarache and the Belgian Nuclear Research Centre SCK-CEN are collaborating on the development and in-pile qualification of subminiature fission chambers (diameter of 1.5 mm). Initially, efforts concentrated on fission chambers for the in-pile measurement of thermal fluxes (with 235 U as fissile material). Meanwhile successful long-term tests of the prototypes have been performed in various environments: in low temperature (40-100 degress Celsius) BR2 pool water (up to a thermal neutron fluence of 3 1 0 21 n/cm 2 ) and in the CALLISTO PWR loop (300 degrees Celsius, 155 bars). The long-term qualification of derived industrial detectors (Photonis CFUZ53) in CALLISTO is still ongoing. However, for various types of irradiations in research reactors, the knowledge of the evolution of the fast neutron flux is even of more interest than the thermal flux data. Therefore the collaboration program was extended to the development and the in-pile qualification of subminiature or miniature fission chambers (with 3 mm diameter) for fast neutron detection, for which 242 Pu was selected as the optimal fissile material. In order to achieve the on-line in-pile measurement of fast neutron flux, the fission chambers will be operated in the Campbelling mode (based on the mean square fluctuation of the detector current). In this mode the gamma induced contribution to the signal can be efficiently suppressed. Moreover, a data processing software will take into account the evolution of the fissile deposit in order to assess on-line the fast flux sensitivity and to correct for the low energy neutron contributions. The final objective is to qualify a Fast Neutron Detector System (FNDS) able to provide on-line data for local fast neutron fluxes in Material Testing Reactors. The on-line measurement of the fast neutron flux would contribute significantly to the characterization of the irradiation conditions during test experiments with materials and innovative fuel elements

  12. Cerebrovascular reactivity measurement in cerebral small vessel disease: Rationale and reproducibility of a protocol for MRI acquisition and image processing.

    Science.gov (United States)

    Thrippleton, Michael J; Shi, Yulu; Blair, Gordon; Hamilton, Iona; Waiter, Gordon; Schwarzbauer, Christian; Pernet, Cyril; Andrews, Peter Jd; Marshall, Ian; Doubal, Fergus; Wardlaw, Joanna M

    2018-02-01

    Background Impaired autoregulation may contribute to the pathogenesis of cerebral small vessel disease. Reliable protocols for measuring microvascular reactivity are required to test this hypothesis and for providing secondary endpoints in clinical trials. Aims To develop and assess a protocol for acquisition and processing of cerebrovascular reactivity by MRI, in subcortical tissue of patients with small vessel disease and minor stroke. Methods We recruited 15 healthy volunteers, testing paradigms using 1- and 3-min 6% CO 2 challenges with repeat scanning, and 15 patients with history of minor stroke. We developed a protocol to measure cerebrovascular reactivity and delay times, assessing tolerability and reproducibility in grey and white matter areas. Results The 3-min paradigm yielded more reproducible data than the 1-min paradigm (CV respectively: 7.9-15.4% and 11.7-70.2% for cerebrovascular reactivity in grey matter), and was less reproducible in white matter (16.1-24.4% and 27.5-141.0%). Tolerability was similar for the two paradigms, but mean cerebrovascular reactivity and cerebrovascular reactivity delay were significantly higher for the 3-min paradigm in most regions. Patient tolerability was high with no evidence of greater failure rate (1/15 patients vs. 2/15 volunteers withdrew at the first visit). Grey matter cerebrovascular reactivity was lower in patients than in volunteers (0.110-0.234 vs. 0.172-0.313%/mmHg; p < 0.05 in 6/8 regions), as was the white matter cerebrovascular reactivity delay (16.2-43.9 vs. 31.1-47.9 s; p < 0.05 in 4/8 regions). Conclusions An effective and well-tolerated protocol for measurement of cerebrovascular reactivity was developed for use in ongoing and future trials to investigate small vessel disease pathophysiology and to measure treatment effects.

  13. Fast measurement of luminosity at LEP by detecting the single bremsstrahlung photons

    International Nuclear Information System (INIS)

    Bini, C.; De Zorzi, G.; Diambrini Palazzi, G.; Di Cosimo, G.; Di Domenico, A.; Gauzzi, P.; Zanello, D.

    1991-01-01

    Luminosity and beam angular divergence have been measured at LEP with a fast monitor based on the single bremsstrahlung process e + e - → e + e - γ. The photons emitted at the interaction point 1 are detected by an electromagnetic calorimeter: both the photon energy and the impact point are measured. The beam angular divergence and the luminosity are determined in few minutes with a statistical error of 1%. With the present experimental layout the systematic error is of few percent; it would be reduced by performing the measurement on an experimental interaction point. (orig.)

  14. Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders

    CERN Document Server

    Kaminskiy, V V; Muchnoi, N Yu; Zhilich, V N

    2017-01-01

    The report describes a method for a fast and precise beam energy measurement in the beam energy range 0.5-2 GeV and its application at various e+e- colliders. Low-energy laser photons interact head-on with the electron or positron beam and produce Compton backscattered photons whose energy is precisely measured by HPGe detector. The method allows measuring the beam energy with relative accuracy of ∼2-5.10-5. The method was successfully applied at VEPP-4M, VEPP-3, VEPP-2000 (BINP, Russia) and BEPC-II (IHEP, China).

  15. The added value of C-reactive protein measurement in diagnosing pneumonia in primary care

    DEFF Research Database (Denmark)

    Minnaard, Margaretha C; de Groot, Joris A H; Hopstaken, Rogier M

    2017-01-01

    BACKGROUND: C-reactive protein (CRP) is increasingly being included in the diagnostic work-up for community-acquired pneumonia in primary care. Its added diagnostic value beyond signs and symptoms, however, remains unclear. We conducted a meta-analysis of individual patient data to quantify...... to a basic signs-and-symptoms prediction model was assessed. Outcome measures were improvement in discrimination between patients with and without pneumonia in primary care and improvement in risk classification, both within the individual studies and across studies. RESULTS: Authors of 8 eligible studies (n...... = 5308) provided their data sets. In all of the data sets, discrimination between patients with and without pneumonia improved after CRP measurement was added to the prediction model (extended model), with a mean improvement in the area under the curve of 0.075 (range 0.02-0.18). In a hypothetical cohort...

  16. Single-phase pressure-drop measurements over low void reactivity fuel

    International Nuclear Information System (INIS)

    Senaratne, U.P.M.; Leung, L.K.H.; Doria, F.J.; Lau, J.H.

    2006-01-01

    An experiment has been performed to obtain pressure-drop measurements over Low Reactivity Fuel (LVRF) bundles in Refrigerant-134a flow. Production LVRF bundles inserted into the test station with either an uncrept or a 5.1% crept flow channel. For comparison purposes, several production Bruce 37-element bundles were also included in the test string. Overall, the single-phase pressure drop of the LVRF bundle is slightly higher than that Bruce 37-element bundle. Pressure-drop measurements were used to derive bundle and loss coefficients for hydraulic calculations in safety analyses. Applying these loss coefficients, an assessment showed that the overall pressure drop over a string of 12 LVRF bundles (after conversion) remains less than that over a string of 13 Bruce 37-element fuel bundles (before conversion) at the Bruce Nuclear Generating Station. (author)

  17. Neutronic characterization of cylindrical core of minor excess reactivity in the nuclear reactor IPEN/MB-01 from the measure of neutron flux distribution and its reactivity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Bitelli, Ulysses d' Utra; Aredes, Vitor O.G.; Mura, Luiz E.C.; Santos, Diogo F. dos; Silva, Alexandre P. da, E-mail: ubitelli@ipen.br, E-mail: vitoraredes@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    When compared to a rectangular parallelepiped configuration the cylindrical configuration of a nuclear reactor core has a better neutron economy because in this configuration the probability of the neutron leakage is smaller, causing an increase in overall reactivity in the system to the same amount of fuel used. In this work we obtained a critical cylindrical configuration with the control rods 89.50% withdraw from the active region of the IPEN/MB-01 core. This is the cylindrical configuration minimum possible excess of reactivity. Thus we obtained a cylindrical configuration with a diameter of only 28 fuel rods with lowest possible excess of reactivity. For this purpose, 112 peripheral fuel rods are removed from standard reactor core (rectangular parallelepiped of 28x28 fuel rods). In this configuration the excesses of reactivity is approximated 279 pcm. From there, we characterize the neutron field by measuring the spatial distribution of the thermal and epithermal neutron flux for the reactor operating power of 83 watts measured by neutron noise analysis technique and 92.08± 0.07 watts measured by activation technique [10]. The values of thermal and epithermal neutron flux in different directions, axial, radial north-south and radial east-west, are obtained in the asymptotic region of the reactor core, away from the disturbances caused by the reflector and control bar, by irradiating thin gold foils infinitely diluted (1% Au - 99% Al) with and without (bare) cadmium cover. In addition to the distribution of neutron flux, the moderator temperature coefficient, the void coefficient, calibration of the control rods were measured. (author)

  18. FFTF [Fast Flux Test Facility] performance measurements for safety, productivity and control

    International Nuclear Information System (INIS)

    A useful set of performance measurements for Safety, Productivity and Control has evolved at the Fast Flux Test Facility (FFTF). In response to declining budgets and the resulting need to safely manage a manpower rampdown, an ''Early Warning System'' was developed in 1984. Its purpose was to monitor the effects of the staffing rampdown such that appropriate remedial action could be taken to correct adverse trends before a significant problem occurred. 1 tab

  19. Measurement of fast assembly spectra using time-of-flight method

    International Nuclear Information System (INIS)

    Duquesne, Henry; Rotival, Michel; Schmitt, Andre; Allard, Christian; De Keyser, Albert; Hortsmann, Henri

    1975-07-01

    Measurement of neutron spectra made in fast subcritical assemblies HUG 3 and PHUG 3 (uranium-graphite and plutonium-graphite) utilizing time-of-flight techniques are described. The matrix were excited by the pulsed neutron source from the BCMN Linac beam impinging on a target of natural uranium. Details of the experimental procedure, safety studies, detector calibration and data reduction are given [fr

  20. Uncertainty Reduction Via Parameter Design of A Fast Digital Integrator for Magnetic Field Measurement

    CERN Document Server

    Arpaia, P; Lucariello, G; Spiezia, G

    2007-01-01

    At European Centre of Nuclear Research (CERN), within the new Large Hadron Collider (LHC) project, measurements of magnetic flux with uncertainty of 10 ppm at a few of decades of Hz for several minutes are required. With this aim, a new Fast Digital Integrator (FDI) has been developed in cooperation with University of Sannio, Italy [1]. This paper deals with the final design tuning for achieving target uncertainty by means of experimental statistical parameter design.

  1. Digital Integrator for Fast Accurate Measurement of Magnetic Flux by Rotating Coils

    CERN Document Server

    Arpaia, P.; Spiezia, G.

    2007-01-01

    A fast digital integrator (FDI) with dynamic accuracy and a trigger frequency higher than those of a portable digital integrator (PDI), which is a state-of-the-art instrument for magnetic measurements based on rotating coils, was developed for analyzing superconducting magnets in particle accelerators. Results of static and dynamic metrological characterization show how the FDI prototype is already capable of overcoming the dynamic performance of PDI as well as covering operating regions that used to be inaccessible

  2. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    DESIG: E 263 09 ^TITLE: Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron ^SIGNUSE: Refer to Guide E 844 for guidance on the selection, irradiation, and quality control of neutron dosimeters. Refer to Practice E 261 for a general discussion of the determination of fast-neutron fluence rate with threshold detectors. Pure iron in the form of foil or wire is readily available and easily handled. Fig. 1 shows a plot of cross section as a function of neutron energy for the fast-neutron reaction 54Fe(n,p)54Mn (1). This figure is for illustrative purposes only to indicate the range of response of the 54Fe(n,p)54Mn reaction. Refer to Guide E 1018 for descriptions of recommended tabulated dosimetry cross sections. 54Mn has a half-life of 312.13 days (3) (2) and emits a gamma ray with an energy of 834.845 keV (5). (2) Interfering activities generated by neutron activation arising from thermal or fast neutron interactions are 2.57878 (46)-h 56Mn, 44.95-d (8) 59Fe, and 5.27...

  3. {sup 20}F power measurement for generation IV sodium fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R.; Normand, S.; Michel, M.; Barbot, L.; Domenech, T.; Boudergui, K.; Bourbotte, J.M.; Kondrasovs, V.; Frelin-Labalme, A.M.; Hamrita, H. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette (France); BAN, G. [ENSICAEN, 6 Boulevard Marechal Juin, F-14050 Caen Cedex 4 (France); Barat, E.; Dautremer, T.; Montagu, T.; Carrel, F. [CEA, LIST, Laboratoire Modelisation Simulation et Systemes, F-91191 Gif-sur-Yvette (France); Brau, H.P. [ICSM, Centre de Marcoule, BP 17171 F-30207 Bagnols sur Ceze (France); Dumarcher, V. [AREVA NP, SET, F-84500 Bollene (France); Portier, J.L. [Centrale PHENIX, Centre de Marcoule, Groupe Essais Statistiques, F-30207 Bagnols sur Ceze (France); Jousset, P. [CEA, LIST, Laboratoire Capteurs Diamant, F-91191 Gif-sur-Yvette (France); Saurel, N. [CEA, DAM, Laboratoire Mesure de Dechets et Expertise, F-21120 Is-sur-Tille, France.F-84500 Bollene (France)

    2010-07-01

    The Phenix nuclear power plant has been a French Sodium Fast Reactor (SFR) prototype producing electrical power between 1973 and 2010. The power was monitored using ex-core neutron measurements. This kind of measurement instantly estimates the power but needs to be often calibrated with the heat balance thermodynamic measurement. Large safety and security margins have then been set not to derive above the nominal operating point. It is important for future SFR to reduce this margin and working closer to the nominal operating point. This work deals with the use of delayed gamma to measure the power. The main activation product contained in the primary sodium coolant is the {sup 24}Na which is not convenient for neutron flux measurement due to its long decay period. The experimental study done at the Phenix reactor shows that the use of {sup 20}F as power tagging agent gives a fast and accurate power measurement closed to the thermal balance measurement thanks to its high energy photon emission (1.634 MeV) and its short decay period (11 s). (authors)

  4. The Perceived Stress Reactivity Scale: Measurement Invariance, Stability, and Validity in Three Countries

    Science.gov (United States)

    Schlotz, Wolff; Yim, Ilona S.; Zoccola, Peggy M.; Jansen, Lars; Schulz, Peter

    2011-01-01

    There is accumulating evidence that individual differences in stress reactivity contribute to the risk for stress-related disease. However, the assessment of stress reactivity remains challenging, and there is a relative lack of questionnaires reliably assessing this construct. We here present the Perceived Stress Reactivity Scale (PSRS), a…

  5. Fast diffuse correlation spectroscopy (DCS) for non-invasive measurement of intracranial pressure (ICP) (Conference Presentation)

    Science.gov (United States)

    Farzam, Parisa; Sutin, Jason; Wu, Kuan-Cheng; Zimmermann, Bernhard B.; Tamborini, Davide; Dubb, Jay; Boas, David A.; Franceschini, Maria Angela

    2017-02-01

    Intracranial pressure (ICP) monitoring has a key role in the management of neurosurgical and neurological injuries. Currently, the standard clinical monitoring of ICP requires an invasive transducer into the parenchymal tissue or the brain ventricle, with possibility of complications such as hemorrhage and infection. A non-invasive method for measuring ICP, would be highly preferable, as it would allow clinicians to promptly monitor ICP during transport and allow for monitoring in a larger number of patients. We have introduced diffuse correlation spectroscopy (DCS) as a non-invasive ICP monitor by fast measurement of pulsatile cerebral blood flow (CBF). The method is similar to Transcranial Doppler ultrasound (TCD), which derives ICP from the amplitude of the pulsatile cerebral blood flow velocity, with respect to the amplitude of the pulsatile arterial blood pressure. We believe DCS measurement is superior indicator of ICP than TCD estimation because DCS directly measures blood flow, not blood flow velocity, and the small cortical vessels measured by DCS are more susceptible to transmural pressure changes than the large vessels. For fast DCS measurements to recover pulsatile CBF we have developed a custom high-power long-coherent laser and a strategy for delivering it to the tissue within ANSI standards. We have also developed a custom FPGA-based correlator board, which facilitates DCS data acquisitions at 50-100 Hz. We have tested the feasibility of measuring pulsatile CBF and deriving ICP in two challenging scenarios: humans and rats. SNR is low in human adults due to large optode distances. It is similarly low in rats because the fast heart rate in this setting requires a high repetition rate.

  6. Long term Suboxone™ emotional reactivity as measured by automatic detection in speech.

    Directory of Open Access Journals (Sweden)

    Edward Hill

    Full Text Available Addictions to illicit drugs are among the nation's most critical public health and societal problems. The current opioid prescription epidemic and the need for buprenorphine/naloxone (Suboxone®; SUBX as an opioid maintenance substance, and its growing street diversion provided impetus to determine affective states ("true ground emotionality" in long-term SUBX patients. Toward the goal of effective monitoring, we utilized emotion-detection in speech as a measure of "true" emotionality in 36 SUBX patients compared to 44 individuals from the general population (GP and 33 members of Alcoholics Anonymous (AA. Other less objective studies have investigated emotional reactivity of heroin, methadone and opioid abstinent patients. These studies indicate that current opioid users have abnormal emotional experience, characterized by heightened response to unpleasant stimuli and blunted response to pleasant stimuli. However, this is the first study to our knowledge to evaluate "true ground" emotionality in long-term buprenorphine/naloxone combination (Suboxone™. We found in long-term SUBX patients a significantly flat affect (p<0.01, and they had less self-awareness of being happy, sad, and anxious compared to both the GP and AA groups. We caution definitive interpretation of these seemingly important results until we compare the emotional reactivity of an opioid abstinent control using automatic detection in speech. These findings encourage continued research strategies in SUBX patients to target the specific brain regions responsible for relapse prevention of opioid addiction.

  7. Airborne measurements of reactive organic trace gases in the atmosphere - with a focus on PTR-MS measurements onboard NASA's flying laboratories

    Science.gov (United States)

    Wisthaler, Armin; Mikoviny, Tomas; Müller, Markus; Schiller, Sven Arne; Feil, Stefan; Hanel, Gernot; Jordan, Alfons; Mutschlechner, Paul; Crawford, James H.; Singh, Hanwant B.; Millet, Dylan

    2017-04-01

    Reactive organic gases (ROGs) play an important role in atmospheric chemistry as they affect the rates of ozone production, particle formation and growth, and oxidant consumption. Measurements of ROGs are analytically challenging because of their large variety and low concentrations in the Earth's atmosphere, and because they are easily affected by measurement artefacts. On aircraft, ROGs are typically measured by canister sampling followed by off-line analysis in the laboratory, fast online gas chromatography or online chemical ionization mass spectrometry. In this work, we will briefly sum up the state-of-the-art in this field before focusing on proton-transfer-reaction mass spectrometry (PTR-MS) and its deployment onboard NASA's airborne science laboratories. We will show how airborne PTR-MS was successfully used in NASA missions for characterizing emissions of ROGs from point sources, for following the photochemical evolution of ROGs in a biomass burning plume, for determining biosphere-atmosphere fluxes of selected ROGs and for validating satellite data. We will also present the airborne PTR-MS instrument in its most recent evolution which includes a radiofrequency ion funnel and ion guide combined with a compact time-of-flight mass spectrometer and discuss its superior performance characteristics. The development of the airborne PTR-MS instrument was supported by the Austrian Federal Ministry for Transport, Innovation and Technology (bmvit) through the Austrian Space Applications Programme (ASAP) of the Austrian Research Promotion Agency (FFG) (grants #833451, #847967). This work was also partly supported by NASA under grant #NNX14AP89G.

  8. Proactive, Reactive, and Romantic Relational Aggression in Adulthood: Measurement, Predictive Validity, Gender Differences, and Association with Intermittent Explosive Disorder

    OpenAIRE

    Murray-Close, Dianna; Ostrov, Jamie M.; Nelson, David A.; Crick, Nicki R.; Coccaro, Emil F.

    2009-01-01

    The psychometric properties of a recently introduced adult self-report of relational aggression are presented. Specifically, the predictive utility of proactive and reactive peer-directed relational aggression, as well as romantic relational aggression, are explored in a large (N = 1387) study of adults. The measure had adequate reliability and validity and the subscales demonstrated unique predictive abilities for a number of dependent variables. In particular, reactive but not proactive rel...

  9. Current and capacitance measurements as a fast diagnostic tool for evaluation of semiconductor parameters

    CERN Document Server

    Kemmer, J; Krause, N; Krieglmeyer, C; Yang Yi

    2000-01-01

    A fast qualitative method is described for evaluation of semiconductor parameters by analyzing both the capacitance/voltage (C/V) and current/voltage (I/V) characteristics of pn- or Schottky-diodes, which are fabricated on the material under investigation. The method is applied for measurement of recombination and generation lifetimes of minority charge carriers and for determination of doping profiles and distribution of active generation/recombination (G/R) centers after irradiation with Am-alpha particles and deep phosphorus implantation. Measurements on epitaxial silicon result in doping profiles and distributions of active impurities within the epi-layer.

  10. Measurement of fast minority /sub 3/He/sup + +/ energy distribution during ICRF heating

    Science.gov (United States)

    Post, D.E. Jr.; Grisham, L.R.; Medley, S.S.

    A method and means for measuring the fast /sub 3/He/sup + +/ distribution during /sub 3/He/sup + +/ minority Ion Cyclotron Resonance Frequency (ICRF) heating is disclosed. The present invention involves the use of 10 to 100 keV beams of neutral helium atoms to neutralize the fast /sub 3/He/sup + +/ ions in a heated plasma by double charge exchange (/sub 3/He/sup + +/ + /sub 4/He/sup 0/ ..-->.. /sub 3/He/sup 0/ + /sub 4/He/sup + +/). The neutralized fast /sub 3/He/sup 0/ atoms then escape from the hot plasma confined by a magnetic field and are detected by conventional neutral particle analyzing means. This technique permits the effectiveness of the coupling of the ion cyclotron waves to the /sub 3/He/sup + +/ minority ions to be accurately measured. The present invention is particularly adapted for use in evaluating the effectiveness of the intermediate coupling between the RF heating and the /sub 3/He/sup + +/ in an energetic toroidal plasma.

  11. Fast Doppler as a novel bedside measure of cerebral perfusion in preterm infants.

    Science.gov (United States)

    Peeples, Eric S; Mehic, Edin; Mourad, Pierre D; Juul, Sandra E

    2016-02-01

    Altered cerebral perfusion from impaired autoregulation may contribute to the morbidity and mortality associated with premature birth. We hypothesized that fast Doppler imaging could provide a reproducible bedside estimation of cerebral perfusion and autoregulation in preterm infants. This is a prospective pilot study using fast Doppler ultrasound to assess blood flow velocity in the basal ganglia of 19 subjects born at 26-32 wk gestation. Intraclass correlation provided a measure of test-retest reliability, and linear regression of cerebral blood flow velocity and heart rate or blood pressure allowed for estimations of autoregulatory ability. The intraclass correlation when imaging in the first 48 h of life was 0.634. We found significant and independent correlations between the systolic blood flow velocity and both systolic blood pressure and heart rate (P = 0.015 and 0.012 respectively) only in the 26-28 wk gestational age infants in the first 48 h of life. Our results suggest that fast Doppler provides reliable bedside measurements of cerebral blood flow velocity at the tissue level in premature infants, acting as a proxy for cerebral tissue perfusion. Additionally, autoregulation appears to be impaired in the extremely preterm infants, even within a normal range of blood pressures.

  12. Method and apparatus for dual-spaced fast/epithermal neutron porosity measurements

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.

    1986-01-01

    A method is described for determining the porosity of earth formations in the vicinity of a well borehole, comprising: (a) irradiating the earth formations in the vicinity of the well borehole with a continuous chemical type source of fast neutrons, (b) detecting the fast neutron population at a first shorter spaced distance from the neutron source in the borehole and generating signals representative thereof, (c) detecting the epithermal neutron population at a second space distance from the neutron source in the borehole and generating signals representative thereof, the second spaced distance being greater than the first spaced distance from the neutron source, (d) forming a ratio of the signals representing the fast and epithermal neutron populations to derive a measurement signal functionally related to the porosity of the earth formations in the vicinity of the borehole, and (e) calibrating the measurement signal according to a predetermined functional relationship to derive a porosity signal quantitatively representative of the porosity of the earth formations in the vicinity of the borehole

  13. Moisture assessment by fast and non-destructive in-situ measurements

    DEFF Research Database (Denmark)

    Møller, Eva B.; Hansen, Ernst Jan de Place; Brandt, Erik

    2014-01-01

    to use, easily applicable and suitable for most porous building materials. Furthermore, the measurements must be reliable at the high end of the hygroscopic area and describe absolute moisture content or corresponding relative humidity. The existing methods for moisture measuring cannot meet...... and brick the moisture content is difficult to determine within a short period time. There is political pressure to include moisture measurements in the report if it does not increase the cost of the inspection significantly. Therefore, a moisture-measuring method is needed that is non-destructive, fast...... these requirements, and those who come close are very expensive. This paper describes a method under development; with simple means and within a few hours, the method can measure the absolute moisture content or the corresponding relative humidity in constructions in a non-destructive way. The method is based...

  14. Moisture assessment by fast and non-destructive in situ measurements

    DEFF Research Database (Denmark)

    Hansen, Kurt Kielsgaard; Møller, Eva B.; Hansen, Ernst Jan de Place

    2014-01-01

    moisture content, which is not revealed by this inspection. The moisture content may become a problem for the buyers. This problem might have been avoided if the moisture content of the Building materials was measured on inspection. This is easily done in wood-based materials but for example in concrete...... and brick the moisture content is difficult to determine within a short period time. There is political pressure to include moisture measurements in the report if it does not increase the cost of the inspection significantly. Therefore, a moisture-measuring method is needed that is non-destructive, fast...... to use, easily applicable and suitable for most porous building materials. Furthermore, the measurements must be reliable at the high end of the hygroscopic area and describe absolute moisture content or corresponding relative humidity. The existing methods for moisture measuring cannot meet...

  15. Fast and direct measurements of the electrical properties of graphene using micro four-point probes

    DEFF Research Database (Denmark)

    Klarskov, Mikkel Buster; Dam, Henrik Friis; Petersen, Dirch Hjorth

    2011-01-01

    We present measurements of the electronic properties of graphene using a repositionable micro four-point probe system, which we show here to have unique advantages over measurements made on lithographically defined devices; namely speed, simplicity and lack of a need to pattern graphene....... Measurements are performed in ambient, vacuum and controlled environmental conditions using an environmental scanning electron microscope (SEM). The results are comparable to previous results for microcleaved graphene on silicon dioxide (SiO2). We observe a pronounced hysteresis of the charge neutrality point......, dependent on the sweep rate of the gate voltage; and environmental measurements provide insight into the sensor application prospects of graphene. The method offers a fast, local and non-destructive technique for electronic measurements on graphene, which can be positioned freely on a graphene flake....

  16. Fast and direct measurements of the electrical properties of graphene using micro four-point probes

    International Nuclear Information System (INIS)

    Klarskov, M B; Dam, H F; Petersen, D H; Hansen, T M; Loewenborg, A; Booth, T J; Schmidt, M S; Boeggild, P; Lin, R; Nielsen, P F

    2011-01-01

    We present measurements of the electronic properties of graphene using a repositionable micro four-point probe system, which we show here to have unique advantages over measurements made on lithographically defined devices; namely speed, simplicity and lack of a need to pattern graphene. Measurements are performed in ambient, vacuum and controlled environmental conditions using an environmental scanning electron microscope (SEM). The results are comparable to previous results for microcleaved graphene on silicon dioxide (SiO 2 ). We observe a pronounced hysteresis of the charge neutrality point, dependent on the sweep rate of the gate voltage; and environmental measurements provide insight into the sensor application prospects of graphene. The method offers a fast, local and non-destructive technique for electronic measurements on graphene, which can be positioned freely on a graphene flake.

  17. Edge turbulence measurement in Heliotron J using a combination of hybrid probe system and fast cameras

    International Nuclear Information System (INIS)

    Nishino, N.; Zang, L.; Takeuchi, M.; Mizuuchi, T.; Ohshima, S.; Kasajima, K.; Sha, M.; Mukai, K.; Lee, H.Y.; Nagasaki, K.; Okada, H.; Minami, T.; Kobayashi, S.; Yamamoto, S.; Konoshima, S.; Nakamura, Y.; Sano, F.

    2013-01-01

    The hybrid probe system (a combination of Langmuir probes and magnetic probes), fast camera and gas puffing system were installed at the same toroidal section to study edge plasma turbulence/fluctuation in Heliotron J, especially blob (intermittent filament). Fast camera views the location of the probe head, so that the probe system yields the time evolution of the turbulence/fluctuation while the camera images the spatial profile. Gas puff at the same toroidal section was used to control the plasma density and simultaneous gas puff imaging technique. Using this combined system the filamentary structure associated with magnetic fluctuation was found in Heliotron J at the first time. The other kind of fluctuation was also observed at another experiment. This combination measurement enables us to distinguish MHD activity and electro-static activity

  18. Accurate and fast 3D surface measurement with temporal-spatial binary encoding structured illumination.

    Science.gov (United States)

    Zhu, Jiangping; Zhou, Pei; Su, Xianyu; You, Zhisheng

    2016-12-12

    Balancing the accuracy and speed for 3D surface measurement of object is crucial in many important applications. Binary encoding pattern utilizing the high-speed image switching rate of digital mirror device (DMD)-based projector could be used as the candidate for fast even high-speed 3D measurement, but current most schemes only enable the measurement speed, which limit their application scopes. In this paper, we present a binary encoding method and develop an experimental system aiming to solve such a situation. Our approach encodes one computer-generated standard 8 bit sinusoidal fringe pattern into multiple binary patterns (sequence) with designed temporal-spatial binary encoding tactics. The binary pattern sequence is then high-speed and in-focus projected onto the surface of tested object, and then captured by means of temporal-integration imaging to form one sinusoidal fringe image. Further the combination of phase-shifting technique and temporal phase unwrapping algorithm leads to fast and accurate 3D measurement. The systematic accuracy better than 0.08mm is achievable. The measurement results with mask and palm are given to confirm the feasibility.

  19. Single-well reactive tracer test and stable isotope analysis for determination of microbial activity in a fast hydrocarbon-contaminated aquifer

    Energy Technology Data Exchange (ETDEWEB)

    Burbery, L.; Cassiani, G.; Andreotti, G.; Ricchiuto, T.; Semple, K.T

    2004-05-01

    Single-well reactive tracer tests, such as the push-pull test are useful tools for characterising in-situ bioattenuation processes in contaminated aquifers. However, the analytical models that are used to interpret push-pull data may be over-simplified, and potentially overlook important processes responsible for the frequent discrepancy between predicted and observed results obtained from push-pull tests. In this study, the limitations underlying the push-pull test methodology were investigated and were supported with results from a push-pull test conducted in a sulphate-reducing aquifer contaminated by crude oil. Poor (<7%) mass recovery was achieved when the push-pull test was performed in a fast-flowing aquifer, preventing a quantifiable reaction rate to be determined. Breakthrough curve data were unexplainable using simplified analytical models, but exhibited trends analogous with tests conducted by others, when >20% mass recoveries were achieved. Push-pull test data collected from sulphate-reducing aquifers indicate that the assumption of a well-mixed batch reactor system is incorrect and that reaction rates obtained from push-pull tests in such systems may be affected by the extraction regime implemented. Evidence of microbial respiration of the reactive tracer was provided by stable sulphur isotope analysis, from which an isotope fractionation factor of +9.9{+-}8.1%o was estimated. The stable isotope data support the argument that reaction rates calculated using push-pull tests are not uniformly distributed in space and time and are likely to be influenced by heterogeneities in the flow field. - Reaction rates calculated by push-pull tests are not uniformly distributed in time and space.

  20. High-sensitive spectrometer of fast neutrons and the results of fast neutron background flux measurements at the Gallium-Germanium Solar Neutrino Experiment

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S

    2002-01-01

    The principle of operation, design, registration system and main characteristics of a fast neutron spectrometer are described. The spectrometer is intended for direct measurements of ultra low fluxes of fast neutrons. It is sensitive to neutron fluxes of 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 and lower. The detection efficiency of fast neutrons with simultaneous energy measurement was determined from Monte-Carlo simulation to be equal to 0.11+-0.01. The background counting rate in the detector corresponds to a neutron flux of (6.5+-2.1)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The natural neutron flux from the surrounding mine rock at the depth of 4600 m of water equivalent was measured to be (7.3+-2.4)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The flux of fast neutrons in the SAGE main room was measured to be <2.3x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in 1.0-11.0 MeV energy range.

  1. Energy measurement of fast ions trapped in the toroidal field ripple of Tore Supra

    International Nuclear Information System (INIS)

    Basiuk, V.; Becoulet, A.; Hutter, T.; Martin, G.; Pecquet, A.L.; Saoutic, B.

    1993-09-01

    During additional heating in Tore Supra (ICRF or NBI) fast ion losses due to the toroidal field ripple were clearly measured by a set of graphite probes. This diagnostic collects the flow of fast ions entering a vertical port and usually shows a maximum flux for ions originating from the vicinity of surface δ * = 0. During the monster sawteeth regime, achieved with ICRF, a remarkable phenomenon was observed: the ejection of fast ions, not correlated with any measured MHD activity. The radial distribution of these ions is quite different from that usually observed exhibiting a peak located in the central section of the plasma. In order to measure the energy distribution of these ions, from 80 keV (energy of the neutral beam injected in Tore Supra) up to 1 MeV (expected during ICRF), a new diagnostic is under construction. The principle of the diagnostic is to discriminate the ions in energy using their Larmor radius (p = 1.3 cm for 100 keV → p = 3.6 cm for 700 keV, B = 4T). The detector is made of a hollow graphite cylinder with a small entrance slot, located in a vertical port on the ion drift side. An array of six metallic collectors placed inside the graphite cylinder intercepts the ions. The current on each collector was estimated at 10 → 100 nA, during ICRF heating. The energy resolution of this diagnostic is expected to be about 20 keV for the lowest energy range and 100 keV for the highest. This type of ruggedized detector might be extrapolated for the measurements of alpha particle losses in future DT experiments. It should also be suitable for the studies of stochastic ripple diffusion. (authors). 3 refs., 9 figs

  2. Fast hydrogen exchange affects 15N relaxation measurements in intrinsically disordered proteins

    International Nuclear Information System (INIS)

    Kim, Seho; Wu, Kuen-Phon; Baum, Jean

    2013-01-01

    Unprotected amide protons can undergo fast hydrogen exchange (HX) with protons from the solvent. Generally, NMR experiments using the out-and-back coherence transfer with amide proton detection are affected by fast HX and result in reduced signal intensity. When one of these experiments, 1 H– 15 N HSQC, is used to measure the 15 N transverse relaxation rate (R 2 ), the measured R 2 rate is convoluted with the HX rate (k HX ) and has higher apparent R 2 values. Since the 15 N R 2 measurement is important for analyzing protein backbone dynamics, the HX effect on the R 2 measurement is investigated and described here by multi-exponential signal decay. We demonstrate these effects by performing 15 N R 2 CPMG experiments on α-synuclein, an intrinsically disordered protein, in which the amide protons are exposed to solvent. We show that the HX effect on R 2 CPMG can be extracted by the derived equation. In conclusion, the HX effect may be pulse sequence specific and results from various sources including the J coupling evolution, the change of steady state water proton magnetization, and the D 2 O content in the sample. To avoid the HX effect on the analysis of relaxation data of unprotected amides, it is suggested that NMR experimental conditions insensitive to the HX should be considered or that intrinsic R 2 CPMG values be obtained by methods described herein.

  3. Cold air challenge for measuring airway reactivity in children: lack of a late asthmatic reaction.

    Science.gov (United States)

    Varga, E M; Eber, E; Zach, M S

    1990-01-01

    Cold air challenge (CACh) for measuring airway reactivity uses respiratory heat or water loss as a bronchoconstrictor stimulus; this stimulus is also important for the development of exercise-induced asthma, for which late asthmatic reactions (LARs) have been described. At 1200 hr on day 1, 22 children with asthma started to record their peak expiratory flow rate (PEFR) in 3 hr intervals until 0900 hr on day 2. At 1000 hr, they underwent a standardized 4 min CACh. Children then inhaled salbutamol and continued to record PEFR until 0900 hr on day 3. As a bronchodilator effect, PEFR measurements were significantly higher 2, 5, and 8 hr after CACh, but subsequently did not differ significantly from pre-CACh values. At 5 hr after CACh, individual values ranged from 95 to 137% of the corresponding pre-CACh measurements, at 8 hr from 94 to 150%, and at 11 hr from 80 to 121%. This random sample of children with asthma demonstrated no LAR after CACh.

  4. A transparent Pyrex μ-reactor for combined in situ optical characterization and photocatalytic reactivity measurements

    International Nuclear Information System (INIS)

    Dionigi, F.; Hansen, O.; Nielsen, M. G.; Chorkendorff, I.; Vesborg, P. C. K.; Pedersen, T.

    2013-01-01

    A new Pyrex-based μ-reactor for photocatalytic and optical characterization experiments is presented. The reactor chamber and gas channels are microfabricated in a thin poly-silicon coated Pyrex chip that is sealed with a Pyrex lid by anodic bonding. The device is transparent to light in the UV-vis-near infrared range of wavelengths (photon energies between ∼0.4 and ∼4.1 eV). The absorbance of a photocatalytic film obtained with a light transmission measurement during a photocatalytic reaction is presented as a proof of concept of a photocatalytic reactivity measurement combined with in situ optical characterization. Diffuse reflectance measurements of highly scattering photocatalytic nanopowders in a sealed Pyrex μ-reactor are also possible using an integrating sphere as shown in this work. These experiments prove that a photocatalyst can be characterized with optical techniques after a photocatalytic reaction without removing the material from the reactor. The catalyst deposited in the cylindrical reactor chamber can be illuminated from both top and bottom sides and an example of application of top and bottom illumination is presented

  5. Quantitative measurements of C-reactive protein using silicon nanowire arrays

    Directory of Open Access Journals (Sweden)

    Min-Ho Lee

    2008-03-01

    Full Text Available Min-Ho Lee, Kuk-Nyung Lee, Suk-Won Jung, Won-Hyo Kim, Kyu-Sik Shin, Woo-Kyeong SeongKorea Electronics Technology Institute, Gyeonggi, KoreaAbstract: A silicon nanowire-based sensor for biological application showed highly desirable electrical responses to either pH changes or receptor-ligand interactions such as protein disease markers, viruses, and DNA hybridization. Furthermore, because the silicon nanowire can display results in real-time, it may possess superior characteristics for biosensing than those demonstrated in previously studied methods. However, despite its promising potential and advantages, certain process-related limitations of the device, due to its size and material characteristics, need to be addressed. In this article, we suggest possible solutions. We fabricated silicon nanowire using a top-down and low cost micromachining method, and evaluate the sensing of molecules after transfer and surface modifications. Our newly designed method can be used to attach highly ordered nanowires to various substrates, to form a nanowire array device, which needs to follow a series of repetitive steps in conventional fabrication technology based on a vapor-liquid-solid (VLS method. For evaluation, we demonstrated that our newly fabricated silicon nanowire arrays could detect pH changes as well as streptavidin-biotin binding events. As well as the initial proof-of-principle studies, C-reactive protein binding was measured: electrical signals were changed in a linear fashion with the concentration (1 fM to 1 nM in PBS containing 1.37 mM of salts. Finally, to address the effects of Debye length, silicon nanowires coupled with antigen proteins underwent electrical signal changes as the salt concentration changed.Keywords: silicon nanowire array, C-reactive protein, vapor-liquid-solid method

  6. Measurements of the reactivity temperature coefficient during zero-power tests in the nuclear power plant Gundremmingen

    International Nuclear Information System (INIS)

    Jaag, Stefan; Grosshans, Ingo

    2008-01-01

    According to the regulatory codes during the zero-power tests before the beginning of each reactor cycle it is mandatory to demonstrate by measurements that the reactivity temperature coefficient reaches negative values before reaching the operation temperature. In the past the reactivity temperature coefficient of the fuel loading composed of uranium fuel elements with final burnup smaller 40 MWd/kg was negative at about 20 C. For modern fuel loadings with higher enriched uranium fuel elements or mixed oxide fuel elements that reach final burnup of 60 MWd/kg the reactivity temperature coefficient is negative at relatively high temperatures. This fact increases the metrological expenses for the conventional measuring method. The authors describe a modified measuring technique that allows a significant time saving.

  7. Experimental study of the large-scale axially heterogeneous liquid-metal fast breeder reactor at the fast critical assembly: Power distribution measurements and their analyses

    International Nuclear Information System (INIS)

    Iijima, S.; Obu, M.; Hayase, T.; Ohno, A.; Nemoto, T.; Okajima, S.

    1988-01-01

    Power distributions of the large-scale axially heterogeneous liquid-metal fast breeder reactor were studied by using the experiment results of fast critical assemblies XI, XII, and XIII and the results of their analyses. The power distributions were examined by the gamma-scanning method and fission rate measurements using /sup 239/Pu and /sup 238/U fission counters and the foil irradiation method. In addition to the measurements in the reference core, the power distributions were measured in the core with a control rod inserted and in a modified core where the shape of the internal blanket was determined by the radial boundary. The calculation was made by using JENDL-2 and the Japan Atomic Energy Research Institute's standard calculation system for fast reactor neutronics. The power flattening trend, caused by the decrease of the fast neutron flux, was observed in the axial and radial power distributions. The effect of the radial boundary shape of the internal blanket on the power distribution was determined in the core. The thickness of the internal blanket was reduced at its radial boundary. The influence of the internal blanket was observed in the power distributions in the core with a control rod inserted. The calculation predicted the neutron spectrum harder in the internal blanket. In the radial distributions of /sup 239/Pu fission rates, the space dependency of the calculated-to-experiment values was found at the active core close to the internal blanket

  8. Relationship between Measures of HIV Reactivation and Decline of the Latent Reservoir under Latency-Reversing Agents.

    Science.gov (United States)

    Petravic, Janka; Rasmussen, Thomas A; Lewin, Sharon R; Kent, Stephen J; Davenport, Miles P

    2017-05-01

    Antiretroviral-free HIV remission requires substantial reduction of the number of latently infected cells and enhanced immune control of viremia. Latency-reversing agents (LRAs) aim to eliminate latently infected cells by increasing the rate of reactivation of HIV transcription, which exposes these cells to killing by the immune system. As LRAs are explored in clinical trials, it becomes increasingly important to assess the effect of an increased HIV reactivation rate on the decline of latently infected cells and to estimate LRA efficacy in increasing virus reactivation. However, whether the extent of HIV reactivation is a good predictor of the rate of decline of the number of latently infected cells is dependent on a number of factors. Our modeling shows that the mechanisms of maintenance and clearance of the reservoir, the life span of cells with reactivated HIV, and other factors may significantly impact the relationship between measures of HIV reactivation and the decline in the number of latently infected cells. The usual measures of HIV reactivation are the increase in cell-associated HIV RNA (CA RNA) and/or plasma HIV RNA soon after administration. We analyze two recent studies where CA RNA was used to estimate the impact of two novel LRAs, panobinostat and romidepsin. Both drugs increased the CA RNA level 3- to 4-fold in clinical trials. However, cells with panobinostat-reactivated HIV appeared long-lived (half-life > 1 month), suggesting that the HIV reactivation rate increased by approximately 8%. With romidepsin, the life span of cells that reactivated HIV was short (2 days), suggesting that the HIV reactivation rate may have doubled under treatment. IMPORTANCE Long-lived latently infected cells that persist on antiretroviral treatment (ART) are thought to be the source of viral rebound soon after ART interruption. The elimination of latently infected cells is an important step in achieving antiretroviral-free HIV remission. Latency-reversing agents

  9. Using Spread Spectrum Transform for Fast and Robust Simultaneous Measurement in Active Sensors with Multiple Emitters

    DEFF Research Database (Denmark)

    Harbo, Anders La-Cour; Stoustrup, Jakob

    2002-01-01

    We present a signal processing algorithm for making robust and simultaneous measurements in an active sensor, which has one or more emitters and a receiver, and which employs some sort of signal processing hardware. Robustness means low sensitivity to time and frequency localized disturbances......, and to white noise. This is achieved partly by using a orthogonal spread spectrum transform for modulating the signals transmitted from the emitters to the receiver, and partly by using a number of transmission channels. The method is fast since the signals are short, and since the method does not rely......-cost active sensors....

  10. How to measure distinct components of visual attention fast and reliably

    DEFF Research Database (Denmark)

    Vangkilde, Signe Allerup; Kyllingsbæk, Søren; Habekost, Thomas

    2009-01-01

    threshold of conscious perception (t0), visual processing speed (C), and storage capacity of visual short-term memory (K) are estimated by use of Bundesen's (1990) Theory of Visual Attention, and the standard error of each estimate is calculated using a bootstrapping procedure. The results from the first......Measuring different attentional processes in a fast and reliable way is important in both clinical and experimental settings. However, most tests of visual attention are either lengthy or lack sensitivity, specificity, and reliability. To address this we developed a ten minute test procedure...... precise and stable estimates of visual attention using only a very brief test....

  11. Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN

    CERN Document Server

    Arpaia, P; Masi, A; Spiezia, G

    2007-01-01

    A Fast Digital Integrator (FDI) has been designed at CERN for increasing performance of state-of-art instruments analyzing superconducting magnets in particle accelerators. In particular, in flux measurement, a bandwidth up to 50-100 kHz and an accuracy of 10 ppm has to be targeted. In this paper, basic concepts and architecture of the developed FDI are highlighted. Numerical metrological analysis of the instrument performance is shown, by focusing both on deterministic errors and on uncertainty in time and amplitude domains.

  12. Precise measurement and accuracy analysis for determining the fast or slow axis of wave plate

    Science.gov (United States)

    Wang, Guixia; Su, Junhong; Xu, Junqi

    2018-01-01

    A method used for precisely measuring the placement of the fast or slow axis of wave plate is presented. In this method, a test wave plate is placed between a polarizer and an analyzer. With the polarizer and analyzer being rotated to different positions, the intensity of the emergent light is measured and one of the optics principal axes of the test wave plate is marked. Then whether this optics principal axis is a fast or slow axis is measured by checking the state of the emergent light polarization. By taking the method of identifying the intensity value near the inflection point, the error caused by directly searching the extreme value of the light intensity can be avoided and the accuracy of determining axis can also be improved significantly. In addition, the source of the determining axis accuracy, which is +/-0.1° . is also analyzed in detail. With regard to the method, there are no requirements for the wavelength of the light source or the linearity, undercurrent and isotropy of the photoelectric detector. Above all, it can be applied to determining the axis of wave plate with any phase retardation.

  13. Fast 3D NIR systems for facial measurement and lip-reading

    Science.gov (United States)

    Brahm, Anika; Ramm, Roland; Heist, Stefan; Rulff, Christian; Kühmstedt, Peter; Notni, Gunther

    2017-05-01

    Structured-light projection is a well-established optical method for the non-destructive contactless three-dimensional (3D) measurement of object surfaces. In particular, there is a great demand for accurate and fast 3D scans of human faces or facial regions of interest in medicine, safety, face modeling, games, virtual life, or entertainment. New developments of facial expression detection and machine lip-reading can be used for communication tasks, future machine control, or human-machine interactions. In such cases, 3D information may offer more detailed information than 2D images which can help to increase the power of current facial analysis algorithms. In this contribution, we present new 3D sensor technologies based on three different methods of near-infrared projection technologies in combination with a stereo vision setup of two cameras. We explain the optical principles of an NIR GOBO projector, an array projector and a modified multi-aperture projection method and compare their performance parameters to each other. Further, we show some experimental measurement results of applications where we realized fast, accurate, and irritation-free measurements of human faces.

  14. Benchmark Evaluation of Dounreay Prototype Fast Reactor Minor Actinide Depletion Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hess, J. D.; Gauld, I. C.; Gulliford, J.; Hill, I.; Okajima, S.

    2017-01-01

    Historic measurements of actinide samples in the Dounreay Prototype Fast Reactor (PFR) are of interest for modern nuclear data and simulation validation. Samples of various higher-actinide isotopes were irradiated for 492 effective full-power days and radiochemically assayed at Oak Ridge National Laboratory (ORNL) and Japan Atomic Energy Research Institute (JAERI). Limited data were available regarding the PFR irradiation; a six-group neutron spectra was available with some power history data to support a burnup depletion analysis validation study. Under the guidance of the Organisation for Economic Co-Operation and Development Nuclear Energy Agency (OECD NEA), the International Reactor Physics Experiment Evaluation Project (IRPhEP) and Spent Fuel Isotopic Composition (SFCOMPO) Project are collaborating to recover all measurement data pertaining to these measurements, including collaboration with the United Kingdom to obtain pertinent reactor physics design and operational history data. These activities will produce internationally peer-reviewed benchmark data to support validation of minor actinide cross section data and modern neutronic simulation of fast reactors with accompanying fuel cycle activities such as transportation, recycling, storage, and criticality safety.

  15. A fast continuous magnetic field measurement system based on digital signal processors

    International Nuclear Information System (INIS)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; Maroussov, V.; Nehring, R.; Nogiec, J.; Orris, D.; Poukhov, O.; Prakoshyn, F.; Schlabach, P.; Tompkins, J.C.

    2005-01-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements

  16. Spectrum measurement of fast neutron through air ducts in water, concrete, and lead

    International Nuclear Information System (INIS)

    Jiang, S.H.; Lin, G.L.; Wu, S.Y.; Liaw, S.Y.

    1983-01-01

    Fast neutron spectral through straight air ducts in water, concrete, and lead have been measured from 1 to 12 MeV by using an NE-213 spectrometer. Wall scattered component has been abstracted from the measured data. It was found that Simon and Clifford's equation can not be applied to describe the measured flux perhaps mainly due to the inadequate assumption of angular distribution of reflected neutrons. The ratio of wall-scattered component to line-of-sight component was found to be dependent on the duct length more or less with an inverse square proportionality for ducts in water and concrete and with an inverse cubic or even more strong proportionality for ducts in lead. (author)

  17. Interpretation of fast measurements of plasma potential, temperature and density in SOL of ASDEX Upgrade

    DEFF Research Database (Denmark)

    Horacek, J.; Adamek, J.; Müller, H.W.

    2010-01-01

    This paper focuses on interpretation of fast (1 µs) and local (2–4 mm) measurements of plasma density, potential and electron temperature in the edge plasma of tokamak ASDEX Upgrade. Steady-state radial profiles demonstrate the credibility of the ball-pen probe. We demonstrate that floating...... consistent; however, those for temperature show an unexpected ~4 mm wide decrease by 10% at the very centre of a blob. In the wall shadow, temperature measured by the swept Langmuir probe yields values ~10 eV, whilst the ball-pen temperature gradient is more steep and credible, dropping down to ~1 eV....... potential fluctuations measured by a Langmuir probe are dominated by plasma electron temperature rather than potential. Spatial and temporal scales are found consistent with expectations based on interchange-driven turbulence. Conditionally averaged signals found for both potential and density are also...

  18. Neutron spectroscopy measurements and modeling of neutral beam heating fast ion dynamics

    International Nuclear Information System (INIS)

    Hellesen, C; Sunden, E Andersson; Conroy, S; Ericsson, G; Johnson, M Gatu; Hjalmarsson, A; Kaellne, J; Ronchi, E; Sjoestrand, H; Weiszflog, M; Albergante, M; Ballabio, L; Gorini, G; Tardocchi, M; Giacomelli, L; Jenkins, I; Voitsekhovitch, I

    2010-01-01

    The energy spectrum of the neutron emission from beam-target reactions in fusion plasmas at the Joint European Torus (JET) has been investigated. Different beam energies as well as injection angles were used. Both measurements and simulations of the energy spectrum were done. The measurements were made with the time-of-flight spectrometer TOFOR. Simulations of the neutron spectrum were based on first-principle calculations of neutral beam deposition profiles and the fast ion slowing down in the plasma using the code NUBEAM, which is a module of the TRANSP package. The shape of the neutron energy spectrum was seen to vary significantly depending on the energy of the beams as well as the injection angle and the deposition profile in the plasma. Cross validations of the measured and modeled neutron energy spectra were made, showing a good agreement for all investigated scenarios.

  19. Upgrade of the Fast Beam Intensity Measurement System for the CERN PS Complex

    CERN Document Server

    Allica, JC; Andreazza, W; Belohrad, D; Favre, G; Favre, N; Jensen, L; Lenardon, F; Vollenberg, W

    2014-01-01

    The CERN Proton Synchrotron complex (CPS) has been operational for over 50 years. During this time the Fast Beam Current Transformers (FBCTs) have only been repaired when they ceased to function, or individually modified to cope with new requests. This strategy resulted in a large variation of designs, making their maintenance difficult and limiting the precision with which comparisons could be made between transformers for the measurement of beam intensity transmission. During the first long shutdown of the CERN LHC and its injectors (LS1) these systems have undergone a major consolidation, with detectors and acquisition electronics upgraded to provide a uniform measurement system throughout the PS complex. This paper discusses the solutions used and analyses the first beam measurement results.

  20. Temperature measurement of an axisymmetric flame using phase shift holographic interferometry with fast Fourier transform

    Science.gov (United States)

    Tieng, S. M.; Lai, W. Z.

    Because of the importance of the temperature scalar measurements in combination diagonostics, application of phase shift holographic interferometry to temperature measurement of an axisymmetrically premixed flame was experimentally investigated. The test apparatus is an axisymmetric Bunsen burner. Propane of 99 percent purity is used as the gaseous fuel. A fast Fourier transform, a more efficient and accurate approach for Abel inversion, is used for reconstructed the axisymmetric temperature field from the interferometric data. The temperature distribution is compared with the thermocouple-measured values. The comparison shows that the proposed technique is satisfactory. The result errors are analyzed in detail. It is shown that this technique overcomes most of the earlier problems and limitations detrimental to the conventional holographic interferometry.

  1. Measurements of total reactive nitrogen during the Airborne Arctic Stratospheric Expedition

    Energy Technology Data Exchange (ETDEWEB)

    Kawa, S.R.; Anderson, L.C. (National Oceanic and Atmospheric Administration (USA) Univ. of Colorado, Boulder (USA)); Fahey, D.W. (National Oceanic and Atmospheric Administration (USA)); Loewenstein, M.; Chan, K.R. (NASA Ames Research Center, Moffett Field, CA (USA))

    1990-03-01

    Composite distributions of measured total reactive nitrogen (NO{sub y}) from the NASA ER-2 during the Airborne Arctic Stratospheric Expedition (AASE) are presented. The observed features of these distributions are discussed in terms of the controlling dynamical, chemical, and microphysical processes. In the latitudinal profile from 58{degree}N to within about 4{degree} poleward of the polar vortex boundary, NO{sub y} conforms closely to predictions of NO{sub y} based on N{sub 2}O measurements. The features of the distribution are apparently dynamically controlled. Poleward of 5{degree} of latitude within the boundary, the average NO{sub y} decreases sharply and is significantly lower than that predicted from N{sub 2}O. This feature is consistent with loss of NO{sub y} through sedimentation of particles containing NO{sub y} in polar stratospheric clouds. The observed loss is not as systematic as in the Antarctic, consistent with the observed differences in season and meteorological conditions between the two campaigns.

  2. Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Huang, J., E-mail: juan.huang@ipp.ac.cn; Wu, C. R.; Hou, Y. M.; Chang, J. F.; Ding, S. Y.; Chen, Y. J.; Jin, Z.; Xu, Z.; Gao, W.; Wang, J. F.; Lyu, B.; Zang, Q.; Zhong, G. Q.; Hu, L.; Wan, B. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui (China); Heidbrink, W. W.; Stagner, L.; Zhu, Y. B. [University of California, Irvine, California 92697 (United States); Hellermann, M. G. von [Diagnostic Team, ITER Organization, Route de Vinon-sur-Verdon 13067 St. Paul Lez Durance (France)

    2016-11-15

    To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the D{sub α} spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.

  3. New Indices of Endothelial Function Measured by Digital Thermal Monitoring of Vascular Reactivity: Data from 6084 Patients Registry

    Directory of Open Access Journals (Sweden)

    Morteza Naghavi

    2016-01-01

    Full Text Available Background. Endothelial function is viewed as a barometer of cardiovascular health and plays a central role in vascular reactivity. Several studies showed digital thermal monitoring (DTM as a simple noninvasive method to measure vascular reactivity that is correlated with atherosclerosis risk factors and coronary artery disease. Objectives. To further evaluate the relations between patient characteristics and DTM indices in a large patient registry. Methods. DTM measures were correlated with age, sex, heart rate, and systolic and diastolic blood pressure in 6084 patients from 18 clinics. Results. DTM vascular reactivity index (VRI was normally distributed and inversely correlated with age (r=-0.21, p<0.0001. Thirteen percent of VRI tests were categorized as poor vascular reactivity (VRI < 1.0, 70 percent as intermediate (1.0 ≤ VRI < 2.0, and 17 percent as good (VRI ≥ 2.0. Poor VRI (<1.0 was noted in 6% of <50 y, 10% of 50–70 y, and 18% of ≥70 y. In multiple linear regression analyses, age, sex, and diastolic blood pressure were significant but weak predictors of VRI. Conclusions. As the largest database of finger-based vascular reactivity measurement, this report adds to prior findings that VRI is a meaningful physiological marker and reflects a high level of residual risk found in patients currently under care.

  4. New Directions in Measuring Reactive and Proactive Aggression: Validation of a Teacher Questionnaire

    Science.gov (United States)

    Polman, Hanneke; de Castro, Bram Orobio; Thomaes, Sander; van Aken, Marcel

    2009-01-01

    The well-known distinction between reactive and proactive aggression is theoretically important but empirically controversial. Recently, aggression researchers have argued that we should separate the form and function of aggression to make a clearer distinction between reactive and proactive aggression. This article describes the validation of a…

  5. Determination of safety rod reactivity - time function from digitally measured safety rod trajectory

    International Nuclear Information System (INIS)

    Pesic, M.; Milovanovic, S.; Milovanovic, T.

    1996-01-01

    Using rod position - time function z(t), obtained using new method and reactivity - position function rho(z), the complex dependence of the reactivity - time function rho(t) for HERBE safety rods is determined. Some improvements, comparing to the previously proposed method, are obtained and analyzed. (author)

  6. The measurement of reactive oxygen species in human neat semen and in suspended spermatozoa: a comparison.

    Science.gov (United States)

    Fingerova, Helena; Oborna, Ivana; Novotny, Jiri; Svobodova, Magda; Brezinova, Jana; Radova, Lenka

    2009-10-27

    It is generally accepted that oxidative stress is an important factor in male infertility because it may impair the physiological function of spermatozoa at the molecular level. Nevertheless, although several approaches have been reported, the imbalance between production of reactive oxygen species (ROS) and activity of the antioxidant defense system in semen is difficult to investigate and remains poorly understood. This study compares measurement of ROS production in neat semen and in washed spermatozoa obtained from the same ejaculate, and suspended in phosphate buffered saline using exactly the same luminol-mediated chemiluminescence method. Ninety one samples were obtained from males of infertile couples and 34 from volunteers with proven fertility. As expected, ROS levels were markedly lower in neat semen than in washed spermatozoa suspensions where seminal plasma with its potent antioxidant capacity was removed. In the cases of both neat semen and washed spermatozoa, ROS production was lowest in samples from normozoospermic males and highest in samples containing more than half million peroxidase-positive leukocytes per milliliter. For all samples, there was a significant positive correlation between ROS production by neat semen and that by washed spermatozoa suspension. Measurement of ROS production in neat semen better reflects actual oxidative status because it detects only the overproduction of ROS which are not effectively scavenged by antioxidant capacity of seminal fluid. The results of our study show a good commutability of both measurements for identification of semen samples with high ROS production. The measurement in neat semen is even less time consuming and therefore easier to implement into laboratory routine.

  7. Electron Paramagnetic Resonance Measurements of Reactive Oxygen Species by Cyclic Hydroxylamine Spin Probes.

    Science.gov (United States)

    Dikalov, Sergey I; Polienko, Yuliya F; Kirilyuk, Igor

    2017-11-17

    Oxidative stress contributes to numerous pathophysiological conditions such as development of cancer, neurodegenerative, and cardiovascular diseases. A variety of measurements of oxidative stress markers in biological systems have been developed; however, many of these methods are not specific, can produce artifacts, and do not directly detect the free radicals and reactive oxygen species (ROS) that cause oxidative stress. Electron paramagnetic resonance (EPR) is a unique tool that allows direct measurements of free radical species. Cyclic hydroxylamines are useful and convenient molecular probes that readily react with ROS to produce stable nitroxide radicals, which can be quantitatively measured by EPR. In this work, we critically review recent applications of various cyclic hydroxylamine spin probes in biology to study oxidative stress, their advantages, and the shortcomings. Recent Advances: In the past decade, a number of new cyclic hydroxylamine spin probes have been developed and their successful application for ROS measurement using EPR has been published. These new state-of-the-art methods provide improved selectivity and sensitivity for in vitro and in vivo studies. Although cyclic hydroxylamine spin probes EPR application has been previously described, there has been lack of translation of these new methods into biomedical research, limiting their widespread use. This work summarizes "best practice" in applications of cyclic hydroxylamine spin probes to assist with EPR studies of oxidative stress. Additional studies to advance hydroxylamine spin probes from the "basic science" to biomedical applications are needed and could lead to better understanding of pathological conditions associated with oxidative stress. Antioxid. Redox Signal. 00, 000-000.

  8. An Ultralow Power Fast-Response Nano-TCD CH4 sensor for UAV Airborne Measurements, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this project, KWJ proposes to develop a low power, fast response, lightweight miniature CH4 measurement system based on KWJ nano-TCD sensor for airborne...

  9. Temperature measurements on fast-rotating objects using a thermographic camera with an optomechanical image derotator

    Science.gov (United States)

    Altmann, Bettina; Pape, Christian; Reithmeier, Eduard

    2017-08-01

    Increasing requirements concerning the quality and lifetime of machine components in industrial and automotive applications require comprehensive investigations of the components in conditions close to the application. Irregularities in heating of mechanical parts reveal regions with increased loading of pressure, draft or friction. In the long run this leads to damage and total failure of the machine. Thermographic measurements of rotating objects, e.g., rolling bearings, brakes, and clutches provide an approach to investigate those defects. However, it is challenging to measure fast-rotating objects accurately. Currently one contact-free approach is performing stroboscopic measurements using an infrared sensor. The data acquisition is triggered so that the image is taken once per revolution. This leads to a huge loss of information on the majority of the movement and to motion blur. The objective of this research is showing the potential of using an optomechanical image derotator together with a thermographic camera. The derotator follows the rotation of the measurement object so that quasi-stationary thermal images during motion can be acquired by the infrared sensor. Unlike conventional derotators which use a glass prism to achieve this effect, the derotator within this work is equipped with a sophisticated reflector assembly. These reflectors are made of aluminum to transfer infrared radiation emitted by the rotating object. Because of the resulting stationary thermal image, the operation can be monitored continuously even for fast-rotating objects. The field of view can also be set to a small off-axis region of interest which then can be investigated with higher resolution or frame rate. To depict the potential of this approach, thermographic measurements on a rolling bearings in different operating states are presented.

  10. A humidity-controlled fast integrated mobility spectrometer (HFIMS for rapid measurements of particle hygroscopic growth

    Directory of Open Access Journals (Sweden)

    T. Pinterich

    2017-12-01

    Full Text Available We present a humidity-controlled fast integrated mobility spectrometer (HFIMS for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA, a relative humidity (RH control unit and a water-based FIMS (WFIMS coupled in series. The WFIMS (Pinterich et al., 2017 combines the fast integrated mobility spectrometer (Kulkarni and Wang, 2006a, b with laminar flow water condensation methodologies (Hering and Stolzenburg, 2005; Spielman et al., 2017. Inside the WFIMS, particles of different electrical mobilities are spatially separated in an electric field, condensationally enlarged and imaged to provide 1 Hz measurements of size distribution spanning a factor of  ∼ 3 in particle diameter, which is sufficient to cover the entire range of growth factor (GF for atmospheric aerosol particles at 90 % RH. By replacing the second DMA of a traditional hygroscopicity tandem DMA (HTDMA system with the WFIMS, the HFIMS greatly increases the speed of particle growth factor measurement. The performance of the HFIMS was evaluated using NaCl particles with well-known hygroscopic growth behavior and further through measurements of ambient aerosols. Results show that the HFIMS can reproduce, within 2 %, the literature values for hygroscopic growth of NaCl particles. NaCl deliquescence was observed between 76 and 77 % RH in agreement with the theoretical value of 76.5 % (Ming and Russell, 2001, and efflorescence relative humidity (43 % was found to lie within the RH range of 41 to 56 % reported in the literature. Ambient data indicate that the HFIMS can measure the hygroscopic growth of five standard dry particle sizes ranging from 35 to 165 nm within less than 3 min, which makes it about 1 order of magnitude faster than traditional HTDMA systems.

  11. Velocity space resolved absolute measurement of fast ion losses induced by a tearing mode in the ASDEX Upgrade tokamak

    Science.gov (United States)

    Galdon-Quiroga, J.; Garcia-Munoz, M.; Sanchis-Sanchez, L.; Mantsinen, M.; Fietz, S.; Igochine, V.; Maraschek, M.; Rodriguez-Ramos, M.; Sieglin, B.; Snicker, A.; Tardini, G.; Vezinet, D.; Weiland, M.; Eriksson, L. G.; The ASDEX Upgrade Team; The EUROfusion MST1 Team

    2018-03-01

    Absolute flux of fast ion losses induced by tearing modes have been measured by means of fast ion loss detectors (FILD) for the first time in RF heated plasmas in the ASDEX Upgrade tokamak. Up to 30 MW m‑2 of fast ion losses are measured by FILD at 5 cm from the separatrix, consistent with infra-red camera measurements, with energies in the range of 250–500 keV and pitch angles corresponding to large trapped orbits. A resonant interaction between the fast ions in the high energy tail of the ICRF distribution and a m/n  =  5/4 tearing mode leads to enhanced fast ion losses. Around 9.3 +/- 0.7 % of the fast ion losses are found to be coherent with the mode and scale linearly with its amplitude, indicating the convective nature of the transport mechanism. Simulations have been carried out to estimate the contribution of the prompt losses. A good agreement is found between the simulated and the measured velocity space of the losses. The velocity space resonances that may be responsible for the enhanced fast ion losses are identified.

  12. Peripheral plasma measurement during SMBI in Heliotron J using fast cameras

    International Nuclear Information System (INIS)

    Nishino, N.; Mizuuchi, T.; Takeuchi, M.; Mukai, K.; Takabatake, Y.; Nagasaki, K.; Kobayashi, S.; Okada, H.; Ohshima, S.; Yamamoto, S.; Minami, T.; Hanatani, K.; Konoshima, S.; Nakamura, Y.; Sano, F.

    2011-01-01

    Since fueling technique is very important for maintaining fusion plasma, supersonic molecular beam injection (SMBI) was studied using mainly fast cameras, Hα measurement, Langmuir/magnetic probes, and electron density/diamagnetic measurement in Heliotron J. Using a fast camera with a tangential view a very bright stripe along the magnetic field line was observed during SMBI. Time-dependent FFT analysis of data from each pixel showed that the low frequency waves rotated around the magnetic field line in a left-handed sense at the initial stage of SMBI. After a few milliseconds they propagated towards the SMBI region along the magnetic field line, and their phase velocities were almost the same. Experimental evidence is consistent with the interpretation as the ion acoustic wave, and the peak frequency of these waves was the same as that of the power spectra of the magnetic probe signals. It suggests the slow magnetoacoustic wave may convert into the ion acoustic wave due to collisions with neutrals.

  13. Cost/schedule performance measurement system utilized on the Fast Flux Test Facility project

    International Nuclear Information System (INIS)

    Brown, R.K.; Frost, R.A.; Zimmerman, F.M.

    1976-01-01

    An Earned Value-Integrated Cost/Schedule Performance Measurement System has been applied to a major nonmilitary nuclear design and construction project. This system is similar to the Department of Defense Cost/Schedule Performance Measurement System. The project is the Fast Flux Test Facility (a Fuels and Materials test reactor for the Liquid Metal Fast Breeder Reactor Program) being built at the Hanford Engineering Development Laboratory, Richland, Washington, by Westinghouse Hanford Company for the U. S. Energy Research and Development Administration. Because the project was well into the construction phase when the Earned Value System was being considered, it was decided that the principles of DOD's Cost/Schedule Control System Criteria would be applied to the extent possible but no major changes in accounting practices or management systems were imposed. Implementation of this system enabled the following questions to be answered: For work performed, how do actual costs compare with the budget for that work. What is the impact of cost and schedule variances at an overall project level composed of different kinds of activities. Without the Earned Value system, these questions could be answered in a qualitative, subjective manner at best

  14. A high precision method for quantitative measurements of reactive oxygen species in frozen biopsies.

    Directory of Open Access Journals (Sweden)

    Kirsti Berg

    Full Text Available OBJECTIVE: An electron paramagnetic resonance (EPR technique using the spin probe cyclic hydroxylamine 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine (CMH was introduced as a versatile method for high precision quantification of reactive oxygen species, including the superoxide radical in frozen biological samples such as cell suspensions, blood or biopsies. MATERIALS AND METHODS: Loss of measurement precision and accuracy due to variations in sample size and shape were minimized by assembling the sample in a well-defined volume. Measurement was carried out at low temperature (150 K using a nitrogen flow Dewar. The signal intensity was measured from the EPR 1st derivative amplitude, and related to a sample, 3-carboxy-proxyl (CP• with known spin concentration. RESULTS: The absolute spin concentration could be quantified with a precision and accuracy better than ±10 µM (k = 1. The spin concentration of samples stored at -80°C could be reproduced after 6 months of storage well within the same error estimate. CONCLUSION: The absolute spin concentration in wet biological samples such as biopsies, water solutions and cell cultures could be quantified with higher precision and accuracy than normally achievable using common techniques such as flat cells, tissue cells and various capillary tubes. In addition; biological samples could be collected and stored for future incubation with spin probe, and also further stored up to at least six months before EPR analysis, without loss of signal intensity. This opens for the possibility to store and transport incubated biological samples with known accuracy of the spin concentration over time.

  15. ADS reactivity measurements from MUSE to TRADE (and where do we go from here?)

    Energy Technology Data Exchange (ETDEWEB)

    Imel, G. [Argonne National Laboratory, 9700 South Cass Ave, Argonne, IL 60439 (United States); Mellier, F.; Jammes, C.; Philibert, H.; Granget, G. [CEA, CEN-Cadarache, 13108 St Paul lez Durance (France); Gonzalez, E.; Villamarin, D. [CIEMAT, Avda Complutense 22, 28040 Madrid (Spain); Rosa, R.; Carta, M.; Monti, S. [ENEA, C.R. Casaccia, via Anguillarese, 301, 00060 S. Maria di Galeria, Rome (Italy); Baeten, P. [SCK-CEN, Boeretang 200, 2400 Mol (Belgium); Billebaud, A. [LPSC, CNRS-IN2P3/UJF, 53 ave des Martyrs, 38026 Grenoble (France)

    2006-07-01

    This paper provides a link between the MUSE (Multiplication avec Source Externe) program performed at CEA-Cadarache in France, and the TRADE (TRIGA Accelerator Driven Experiment) program performed at ENEA-Casaccia in Italy. In both programs, extensive measurements were made to determine the best methods for sub-criticality measurements in an accelerator-driven system. A very serious attempt was made to quantify the uncertainties associated with such measurements. While both MUSE and TRADE studied the methods of sub-criticality determination, in fact the two systems are very different. MUSE was a fast system with MOX fuel (generation time around 0.5 {mu}s), and TRADE was performed in a TRIGA reactor (generation time around 50 {mu}s). This paper will summarize the important results of these two experiments, with the main purpose being to tie them together to attempt to draw generic conclusions that can be applied in the future to a real ADS. In addition, this paper will briefly discuss the next series of experiments that will continue this work in the U.S. (RACE, Reactor Accelerator Coupled Experiments), Belarus (YALINA), Belgium (GUINEVERE), and Russia (SAD, Sub-critical Assembly Dubna). MUSE and TRADE have contributed greatly to our understanding of the uncertainties associated with sub-critical measurements, but there are still some gaps that must be covered. This paper will describe the gaps that exist, and demonstrate how the above future programs will fill in the missing information needed for the design of an actual ADS system in the future. (authors)

  16. Cross-reactivity of amino acids and other compounds in the biuret reaction: interference with urinary peptide measurements.

    Science.gov (United States)

    Hortin, Glen L; Meilinger, Bonnie

    2005-08-01

    Biuret assays for total protein measurement are considered to react with all peptides longer than 2 residues. Some studies using biuret assays of urine suggest that small peptides generally are more abundant than proteins in urine, but it is not clear whether this is a problem of assay specificity. We analyzed the specificity and kinetics of a biuret reaction for solutions of amino acids, organic compounds, peptides, proteins, and ultrafiltered urine specimens and compared the results with standard clinical assays for protein measurement. The biuret assay cross-reacted with several amino acids, dipeptides, and other organic compounds able to form 5- or 6-member ring chelation complexes with copper. Reactions with amino acids and dipeptides had higher absorbance maxima (blue color) than with larger peptides and proteins (purple). Compounds forming potential 4-, 7-, 8-, or 9-member ring complexes with copper had low reactivity. Amino acid amides, dipeptides, and longer peptides had substantial reactivity, except those containing proline. Proteins and polypeptides had similar biuret reactivities per peptide bond, but reaction kinetics were slower for proteins than peptides. Urine specimens ultrafiltered through 3-kDa-cutoff membranes had substantial biuret reactivity, but absorbance maxima were consistent with cross-reactive amino acids rather than peptides. Many compounds, including amino acids, amino acid derivatives, and dipeptides, cross-react in biuret assays. Our studies improve understanding of the specificity of endpoint and kinetic biuret assays widely used in clinical laboratories. Amino acids, urea, and creatinine contribute to overestimation of urinary peptide content by biuret assays.

  17. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Aluminum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures measuring reaction rates by the activation reaction 27Al(n,α)24Na. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 6.5 MeV and for irradiation times up to about 2 days (for longer irradiations, see Practice E261). 1.3 With suitable techniques, fission-neutron fluence rates above 106 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast neutron detectors are referenced in Practice E261. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Novel single-beam optical spectrophotometer for fast luminescence, absorption, and reflection measurements of turbid materials

    Science.gov (United States)

    Schmidt, Werner

    1995-02-01

    A novel spectrophotometer based on the deflection of a secondary element for measuring clear and highly turbid materials within the millisecond time range is developed. The number of optical components of the monochromator is reduced to the absolute minimum. This results in excellent light throughput and a low stray-light level. The spectrophotometer has been designed allowing spectral measurements of absorption, transmission, reflection, and luminescence in a single-beam mode, as documented by various examples. Its design is highly flexible and the price/quality relation might be adopted to the envisaged purpose. The main philosophy is to relocate as many functions as possible form the hardware to the software part of the spectrophotometer. Several novel procedures based on old concepts are proposed. An appropriate computer program providing data acquisition, control functions as well as numerous analytical capabilities is developed on the basis of the compiler language power basic and indispensably 'fast' routines are written in assembler language.

  19. Direct mass measurements of light neutron-rich nuclei using fast recoil spectrometers

    International Nuclear Information System (INIS)

    Vieira, D.J.; Wouters, J.M.

    1987-01-01

    Extensive new mass measurement capabilities have evolved with the development of recoil spectrometers. In the Z = 3 to 9 neutron-rich region alone, 12 neutron-rich nuclei have been determined for the first time by the fast-recoil direct mass measurement method. A recent experiment using the TOFI spectrometer illustrates this technique. A systematic investigation of nuclei that lie along or near the neutron-drip line has provided a valuable first glimpse into the nuclear structure of such nuclei. No evidence for a large single-particle energy gap at N = 14 is observed; however, a change in the two-neutron separation model calculations, and is interpreted in terms of the smaller 1s/sub 1/2/ - 1s/sub 1/2/ interaction compared to that of the 0d/sub 5/2/ - 0d/sub 5/2/ neutron-neutron interaction. 18 refs., 7 figs., 1 tab

  20. Metrological Characterisation of a Fast Digital Integrator for Magnetic Measurements at CERN

    CERN Document Server

    Arpaia, P; Masi, A; Spiezia, G

    2007-01-01

    A Fast Digital Integrator (FDI) was designed to satisfy new more demanding requirements of dynamic accuracy and trigger frequency in magnetic measurements based on rotating coil systems for analyzing superconducting magnets in particle accelerators. In particular, in flux measurement, a bandwidth up to 50-100 kHz and a dynamic accuracy of 10 ppm are targeted. In this paper, results of static and dynamic metrological characterization of the FDI prototype and of the Portable Digital Integrator (PDI), heavely used at CERN and in many sub-nuclear laboratories, are compared. Preliminary results show how the initial prototype of FDI is already capable of both overcoming dynamic performance of PDI and covering operating regions inaccessible before.

  1. Le Châtelier's conjecture: Measurement of colloidal eigenstresses in chemically reactive materials

    Science.gov (United States)

    Abuhaikal, Muhannad; Ioannidou, Katerina; Petersen, Thomas; Pellenq, Roland J.-M.; Ulm, Franz-Josef

    2018-03-01

    Volume changes in chemically reactive materials, such as hydrating cement, play a critical role in many engineering applications that require precise estimates of stress and pressure developments. But a means to determine bulk volume changes in the absence of other deformation mechanisms related to thermal, pressure and load variations, is still missing. Herein, we present such a measuring devise, and a hybrid experimental-theoretical technique that permits the determination of colloidal eigenstresses. Applied to cementitious materials, it is found that bulk volume changes in saturated cement pastes at constant pressure and temperature conditions result from a competition of repulsive and attractive phenomena that originate from the relative distance of the solid particles - much as Henry Louis Le Châtelier, the father of modern cement science, had conjectured in the late 19th century. Precipitation of hydration products in confined spaces entails a repulsion, whereas the concurrent reduction in interparticle distance entails activation of attractive forces in charged colloidal particles. This cross-over from repulsion to attraction can be viewed as a phase transition between a liquid state (below the solid percolation) and the limit packing of hard spheres, separated by an energy barrier that defines the temperature-dependent eigenstress magnitude.

  2. Measuring Empathic Tendencies: Reliability And Validity of the Dutch Version of the Interpersonal Reactivity Index

    Directory of Open Access Journals (Sweden)

    Kim De Corte

    2007-10-01

    Full Text Available The Interpersonal Reactivity Index (IRI; Davis, 1980 is a commonly used self-report instrument designed to assess empathic tendencies. The IRI consists of four separate subscales: Perspective Taking (PT, Fantasy (FS, Empathic Concern (EC, and Personal Distress (PD. The objective of this study was to examine the psychometric properties of a Dutch version of the IRI. The IRI was administered to a Dutch sample of 651 normal functioning adults. The factor structure of the IRI was examined by using confirmatory factor analysis (CFA. The results of the CFA revealed that there is room for improvement and modification of the original theoretical model. The validity of the IRI was tested using internal criteria (i. e., scale intercorrelations and external criteria (i. e., correlations with subscales of the EQ-i (Bar-On, 1997, the NEO-FFI (Hoekstra, Ormel, & De Fruyt, 1996, Mach-IV (Van Kenhove, Vermeir, & Verniers, 2001, Rosenberg Self-esteem Scale (Rosenberg, 1965, and the WAIS-III (Wechsler, 2000. Overall, the internal consistency, construct validity, and factor structure of scores from the Dutch version of the IRI suggest that it is a useful instrument to measure people's self-reported empathic tendencies.

  3. Measurements of fast electron beams and soft X-ray emission from plasma-focus experiments

    Directory of Open Access Journals (Sweden)

    Surała Władysław

    2016-06-01

    Full Text Available The paper reports results of the recent experimental studies of pulsed electron beams and soft X-rays in plasma-focus (PF experiments carried out within a modified PF-360U facility at the NCBJ, Poland. Particular attention was focused on time-resolved measurements of the fast electron beams by means of two different magnetic analyzers, which could record electrons of energy ranging from about 41 keV to about 715 keV in several (6 or 8 measuring channels. For discharges performed with the pure deuterium filling, many strong electron signals were recorded in all the measuring channels. Those signals were well correlated with the first hard X-ray pulse detected by an external scintillation neutron-counter. In some of the analyzer channels, electron spikes (lasting about dozens of nanoseconds and appearing in different instants after the current peculiarity (so-called current dip were also recorded. For several discharges, fast ion beams, which were emitted along the z-axis and recorded with nuclear track detectors, were also investigated. Those measurements confirmed a multibeam character of the ion emission. The time-integrated soft X-ray images, which were taken side-on by means of a pinhole camera and sensitive X-ray films, showed the appearance of some filamentary structures and so-called hot spots. The application of small amounts of admixtures of different heavy noble gases, i.e. of argon (4.8% volumetric, krypton (1.6% volumetric, or xenon (0.8% volumetric, decreased intensity of the recorded electron beams, but increased intensity of the soft X-ray emission and showed more distinct and numerous hot spots. The recorded electron spikes have been explained as signals produced by quasi-mono-energetic microbeams emitted from tiny sources (probably plasma diodes, which can be formed near the observed hot spots.

  4. Ultrasonic Measurement of Velocity Profile on Bubbly Flow Using Fast Fourier Transform (FFT) Technique

    Science.gov (United States)

    Wongsaroj, W.; Hamdani, A.; Thong-un, N.; Takahashi, H.; Kikura, H.

    2017-10-01

    In two-phase bubbly flow, measurement of liquid and bubble velocity is a necessity to understand fluid characteristic. The conventional ultrasonic velocity profiler (UVP), which has been known as a nonintrusive measurement technique, can measure velocity profile of liquid and bubble simultaneously by applying a separation technique for both phases (liquid and bubble) and transparent test section is unnecessary. The aim of this study was to develop a new technique for separating liquid and bubble velocity data in UVP method to measure liquid and bubble velocity profiles separately. The technique employs only single resonant frequency transducer and a simple UVP system. An extra equipment is not required. Fast Fourier Transform (FFT) based frequency estimator paralleled with other signal processing techniques, which is called as proposed technique, was proposed to measure liquid and bubble velocity separately. The experimental facility of two-phase bubbly flow in the vertical pipe was constructed. Firstly, the Doppler frequency estimation by using the FFT technique was evaluated in single-phase liquid flow. Results showed that FFT technique showed a good agreement with autocorrelation and maximum likelihood estimator. Then, separation of liquid and bubble velocity was demonstrated experimentally in the two-phase bubbly flow. The proposed technique confirmed that liquid and bubble velocity could be measured efficiently.

  5. Measurement based analysis of active and reactive power losses in a distribution network with wind farms and CHPs

    DEFF Research Database (Denmark)

    Lund, Torsten

    2007-01-01

    The paper presents an investigation of the active and reactive power losses in a distribution network with wind turbines and combined heat and power plants. The investigation is based on 15 min average power measurements and load flow calculations in the power system simulation tool PowerFactory...

  6. Oscillator measurements of the reactivity changes resulting from the irradiation of low enrichment particulate fuel in the Dragon reactor

    International Nuclear Information System (INIS)

    Burbidge, B.L.H.; Franklin, B.M.; Small, V.G.

    1983-01-01

    This Report describes a series of experiments carried out as a joint UKAEA/CEA/DRAGON project to determine the reactivity changes of low-enrichment particulate fuel samples following their irradiation in the DRAGON reactor to various levels up to approximately 60,000 MWD/Te. The samples are described, together with the method of measurement of reactivity in the Winfrith reactor HECTOR, which was an extension of the well-known Oscillator Technique to yield simultaneously overall reactivity changes and changes in macroscopic absorption cross-sections. Measurements were carried out at room temperature in two reactor spectra; a thermal spectrum and one typical of an HTR type reactor. The resultant reactivity changes are presented together with the relevant sample burn-ups as determined by #betta#-scanning methods and, in some cases, by rigorous chemical analysis. The results of supporting measurements are also reported, carried out to characterise the neutron spectra in which the oscillator measurements were made and to determine the neutron flux distributions in the HECTOR reactor. (author)

  7. Rethinking Dithiothreitol-Based Particulate Matter Oxidative Potential: Measuring Dithiothreitol Consumption versus Reactive Oxygen Species Generation.

    Science.gov (United States)

    Xiong, Qianshan; Yu, Haoran; Wang, Runran; Wei, Jinlai; Verma, Vishal

    2017-06-06

    We measured the rate of generation of reactive oxygen species (ROS) [hydroxyl radicals ( • OH) and hydrogen peroxide (H 2 O 2 )] catalyzed by ambient particulate matter (PM) in the dithiothreitol (DTT) assay. To understand the mechanism of ROS generation, we tested several redox-active substances, such as 9,10-phenanthrenequinone (PQ), 5-hydroxy-1,4-naphthoquinone (5H-1,4NQ), 1,2-naphthoquinone (1,2-NQ), 1,4-naphthoquinone (1,4-NQ), copper(II), manganese(II), and iron (II and III). Both pure compounds and their mixtures show different patterns in DTT oxidation versus ROS generation. The quinones, known to oxidize DTT in the efficiency order of PQ > 5H-1,4NQ > 1,2-NQ > 1,4-NQ, show a different efficiency order (5H-1,4NQ > 1,2-NQ ≈ PQ > 1,4-NQ) in the ROS generation. Cu(II), a dominant metal in DTT oxidation, contributes almost negligibly to the ROS generation. Fe is mostly inactive in DTT oxidation, but shows synergistic effect in • OH formation in the presence of other quinones (mixture/sum > 1.5). Ten ambient PM samples collected from an urban site were analyzed, and although DTT oxidation was significantly correlated with H 2 O 2 generation (Pearson's r = 0.91), no correlation was observed between DTT oxidation and • OH formation. Our results show that measuring both DTT consumption and ROS generation in the DTT assay is important to incorporate the synergistic contribution from different aerosol components and to provide a more inclusive picture of the ROS activity of ambient PM.

  8. Determination of reactivity coefficients from measurable effects of small external perturbations using a bank of Kalman filters

    International Nuclear Information System (INIS)

    Racz, A.

    1990-12-01

    The goal of this paper is to present a method for the determination of reactivity coefficients in a nuclear power reactor in operation. A method based on Kalman filtering technique and the Magill-Bogler test is proposed for the determination of reactivity coefficients from measured effects of small external perturbation introduced into a steady-state power reactor. Numerical experiments are presented to justify the procedure. A realistic problem is considered: the calculation of the control rod worth. Finally a possible way is given to check the goodness of the estimation. (author) 16 refs.; 4 figs

  9. Optimal measurement uncertainties for materials accounting in a fast breeder reactor spent-fuel reprocessing plant

    International Nuclear Information System (INIS)

    Dayem, H.A.; Kern, E.A.; Markin, J.T.

    1982-01-01

    Optimization techniques are used to calculate measurement uncertainties for materials accountability instruments in a fast breeder reactor spent-fuel reprocessing plant. Optimal measurement uncertainties are calculated so that performance goals for detecting materials loss are achieved while minimizing the total instrument development cost. Improved materials accounting in the chemical separations process (111 kg Pu/day) to meet 8-kg plutonium abrupt (1 day) and 40-kg plutonium protracted (6 months) loss-detection goals requires: process tank volume and concentration measurements having precisions less than or equal to 1%; accountability and plutonium sample tank volume measurements having precisions less than or equal to 0.3%, short-term correlated errors less than or equal to 0.04%, and long-term correlated errors less than or equal to 0.04%; and accountability and plutonium sample tank concentration measurements having precisions less than or equal to 0.4%, short-term correlated errors less than or equal to 0.1%, and long-term correlated errors less than or equal to 0.05%

  10. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Copper

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 63Cu(n,α)60Co. The cross section for 60Co produced in this reaction increases rapidly with neutrons having energies greater than about 5 MeV. 60Co decays with a half-life of 1925.27 days (±0.29 days)(1) and emits two gamma rays having energies of 1.1732278 and 1.332492 MeV (1). The isotopic content of natural copper is 69.17 % 63Cu and 30.83 % 65Cu (2). The neutron reaction, 63Cu(n,γ)64Cu, produces a radioactive product that emits gamma rays which might interfere with the counting of the 60Co gamma rays. 1.2 With suitable techniques, fission-neutron fluence rates above 109 cm−2·s−1 can be determined. The 63Cu(n,α)60Co reaction can be used to determine fast-neutron fluences for irradiation times up to about 15 years (for longer irradiations, see Practice E261). 1.3 Detailed procedures for other fast-neutron detectors are referenced in Practice E261. 1.4 This standard does not purport to address all of the...

  11. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    International Nuclear Information System (INIS)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design

  12. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design.

  13. Endothelial dysfunction in obstructive sleep apnea measured by peripheral arterial tone response in the finger to reactive hyperemia.

    Science.gov (United States)

    Itzhaki, Sarah; Lavie, Lena; Pillar, Giora; Tal, Galit; Lavie, Peretz

    2005-05-01

    The aim of this study was to investigate endothelial functioning in sleep apnea patients using a novel plethysmographic device that monitors peripheral arterial tone response in the finger to reactive hyperemia induced by forearm ischemia. Forty-six sleep apnea patients, 74.0% men, mean age 46.8 +/- 9.3 years, and 17 control subjects without sleep apnea, 64.7% men, mean age 47.1 +/- 6.7 years. Eight-bed Technion Sleep Medicine Center in Haifa, Israel. Endothelial functioning assessed by the reactive hyperemia peripheral arterial tone index was measured twice, before sleep and after waking from sleep monitored by polysomnography in the laboratory. The reactive hyperemia peripheral arterial tone index was calculated as the average amplitude of the peripheral arterial tone signal after the cuff deflation divided by the average amplitude before the cuff inflation. Morning index of endothelial functioning was significantly lower in patients with moderate to severe sleep apnea (apnea-hypopnea index > or = 30) than in patients with mild sleep apnea (30 disease had significantly lower morning and evening indexes of endothelial functioning than patients without such a history. Multivariate analysis revealed that apnea-hypopnea index and sleep efficiency were significant predictors of the morning index. Measurements of the response of the peripheral arterial tone in the finger to reactive hyperemia can be used as a substitute for the brachial artery ultrasound technique to measure endothelial functioning in patients with sleep apnea.

  14. Measurement of fluorine total concentration in dental enamel using fast neutron activation

    International Nuclear Information System (INIS)

    Mouadili, A.; Vernais, J.; Isabelle, D.B.

    1988-01-01

    Fluorine which is present in dental enamel, at the level of a few tens to a few hundred ppm, plays an important role in the behaviour of this tissue. Therefore quantitative determination is of interest for particular studies of the dental system. We present a nuclear nondestructive method to determine the total fluorine content in dental enamel by cyclotron-produced fast-neutron activation. The 19 F(n,2n) reaction leads to 18 F which is a β + emitter with a 109.8 min half-life. The irradiated sample activity is measured by detecting in coincidence the annihilation photons. A fluorine standard is used for calibration. The detection limit is of the order of 1 ppm, while the reproducibility is better than 95% [pt

  15. Open photoacoustic cell for thermal diffusivity measurements of a fast hardening cement used in dental restoring

    Science.gov (United States)

    Astrath, F. B. G.; Astrath, N. G. C.; Baesso, M. L.; Bento, A. C.; Moraes, J. C. S.; Santos, A. D.

    2012-01-01

    Thermal diffusivity and conductivity of dental cements have been studied using open photoacoustic cell (OPC). The samples consisted of fast hardening cement named CER, developed to be a root-end filling material. Thermal characterization was performed in samples with different gel/powder ratio and particle sizes and the results were compared to the ones from commercial cements. Complementary measurements of specific heat and mass density were also performed. The results showed that the thermal diffusivity of CER tends to increase smoothly with gel volume and rapidly against particle size. This behavior was linked to the pores size and their distribution in the samples. The OPC method was shown to be a valuable way in deriving thermal properties of porous material.

  16. On Developing a Spectroscopic System for Fast Gas Temperature Measurements in Combustion Environments

    DEFF Research Database (Denmark)

    Evseev, Vadim; Clausen, Sønnik

    2009-01-01

    is not high enough to trace fast temperature variations which are of great importance for complete combustion diagnostics. To eliminate the above mentioned shortcoming, a new IR spectroscopic-imaging system has been developed at Risø DTU. The schematic of the system is presented. Results on lab and industrial......Fourier Transform Infra Red (FTIR) spectroscopy techniques are known to provide reliable results for gas temperature measurements and can be comparatively easily performed on an industrial scale such as a boiler on a power plant or an exhaust of a ship engine cylinder. However temporal resolution...... scale are discussed. System’s flexibility and changeability which enable applying of a number of other methods for combustion diagnostics are demonstrated....

  17. Measurement of small-angle elastic scattering cross sections of fast neutron

    International Nuclear Information System (INIS)

    Wan Dairong; Dai Yunsheng; Liang Xuecai; Cao Jianhua

    1993-11-01

    A position-sensitive detector has been developed for studying small angle scattering of fast neutrons. The detector mainly consists of two photomultiplier tubes to monitor the liquid scintillator. The time difference between two signals from two photomultiplier tubes is used to determine the position of light emitted. The 14.7 MeV neutron elastic scattering differential cross section of Zr, Nb, Ti and Pb were measured by position-sensitive detector and associated particle time-of-flight method at the angles from 3 deg to 15 deg. The corrections for neutron fluence attenuation, multiple scattering and finite geometry are performed by using Monte-Carlo method. The experimental results provide data needed in nuclear engineering design

  18. d-3He reaction measurements during fast wave minority heating in PLT

    International Nuclear Information System (INIS)

    Chrien, R.E.; Strachan, J.D.

    1983-01-01

    Time- and energy-resolved d- 3 He fusion reactions have been measured to infer the energy of the d + or He ++ minority ions heated near their cyclotron frequency by the magnetosonic fast wave. The average energy of the reacting 3 He ions during 3 He minority heating is in the range of 100 to 400 keV, as deduced from the magnitude of the reaction rate, its decay time, and the energy spread of the proton reaction products. The observed reaction rate and its scaling with wave power and electron density and temperature are in qualitative agreement with a radial reaction rate model using the minority distribution predicted from quasilinear velocity space diffusion. Oscillations in the reaction rate are observed concurrent with sawtooth and m = 2 MHD activity in the plasma

  19. Measurements of timing resolution of ultra-fast silicon detectors with the SAMPIC WTDC

    CERN Document Server

    Breton, Dominique

    2016-11-01

    The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter (TDC) and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to maximize time resolution. A software framework has been developed to analyse the SAMPIC output data and extract timing information by using either a constant fraction discriminator or a fast cross-correlation algorithm. SAMPIC timing capabilities together with the software framework have been tested using Gaussian signals generated by a signal generator or by silicon detectors pulsed with an infra-red laser. Under these ideal experimental conditions, the SAMPIC chip has proven to be capable of timing resolutions down to 4 (40) ps with synthesized (silicon detector) signals.

  20. Inverse correlation between reactive oxygen species in unwashed semen and sperm motion parameters as measured by a computer-assisted semen analyzer.

    Science.gov (United States)

    Takeshima, Teppei; Yumura, Yasushi; Yasuda, Kengo; Sanjo, Hiroyuki; Kuroda, Shinnosuke; Yamanaka, Hiroyuki; Iwasaki, Akira

    2017-01-01

    This study investigated the correlation between sperm motion parameters obtained by a computer-assisted semen analyzer and levels of reactive oxygen species in unwashed semen. In total, 847 patients, except for azoospermic patients were investigated. At the time of each patient's first consultation, semen parameters were measured using SMAS™ or CellSoft 3000™, and production of reactive oxygen species was measured using a computer-driven LKB Wallac Luminometer 1251 Analyzer. The patients were divided into two groups: reactive oxygen species - positive and negative. The semen parameters within each group were measured using one of the two computer-assisted semen analyzer systems and then compared. Correlations between reactive oxygen species levels and sperm motion parameters in semen from the reactive oxygen species - positive group were also investigated. Reactive oxygen species were detected in semen samples of 282 cases (33.3%). Sperm concentration (P reactive oxygen species - positive group than in the reactive oxygen species - negative group. Among the sperm motion parameters in the reactive oxygen species - positive group, sperm concentration (P reactive oxygen species levels. Therefore, this study demonstrated that excessive reactive oxygen species in semen damage sperm concentration, motility, and other sperm motion parameters.

  1. Measuring fast electron distribution functions at intensities up to 10{sup 21} W cm{sup -2}

    Energy Technology Data Exchange (ETDEWEB)

    Booth, N., E-mail: nicola.booth@stfc.ac.uk [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot OX11 0QN (United Kingdom); Clarke, R.J. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot OX11 0QN (United Kingdom); Doria, D. [Department of Physics and Mathematics, Queen' s University Belfast, Belfast BT1 4NN (United Kingdom); Gizzi, L.A. [ILIL-IPCF, Consiglio Nazionale delle Richerche, Pisa (Italy); Gregori, G. [Department of Physics, University of Oxford OX4 1PJ (United Kingdom); Hakel, P. [Department of Physics, College of Science, University of Nevada, Reno, NV 89557-0208 (United States); Koester, P.; Labate, L.; Levato, T. [ILIL-IPCF, Consiglio Nazionale delle Richerche, Pisa (Italy); Li, B. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot OX11 0QN (United Kingdom); Makita, M. [Department of Physics and Mathematics, Queen' s University Belfast, Belfast BT1 4NN (United Kingdom); Mancini, R.C. [Department of Physics, College of Science, University of Nevada, Reno, NV 89557-0208 (United States); Pasley, J. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot OX11 0QN (United Kingdom); Rajeev, P.P. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot OX11 0QN (United Kingdom); Riley, D. [Department of Physics and Mathematics, Queen' s University Belfast, Belfast BT1 4NN (United Kingdom); Robinson, A.P.L. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot OX11 0QN (United Kingdom); Wagenaars, E.; Waugh, J.N.; Woolsey, N.C. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2011-10-11

    Here we present results from ultra-intense experiments demonstrating the viability of polarization spectroscopy as a diagnostic of the electron return current and spatial anisotropy and distribution function of the fast electron beam. The measurements extend to ultra-relativistic intensities of 10{sup 21} W cm{sup -2}, including laser-plasma interaction regimes important for fast ignition studies, for example HiPER, and the development of secondary sources from next generation ultra-short pulse, ultra-intense laser facilities such as Astra-Gemini and ELI. As an in situ diagnostic, spectroscopic measurements are vital to understanding fast electron beams, enabling extrapolation of results to define fast ignition inertial confinement fusion and secondary source facilities.

  2. Measurement and modeling of engineered nanoparticle transport and aging dynamics in a reactive porous medium

    Science.gov (United States)

    Naftaly, Aviv; Dror, Ishai; Berkowitz, Brian

    2016-07-01

    A continuous time random walk particle tracking (CTRW-PT) method was employed to model flow cell experiments that measured transport of engineered nanoparticles (ENPs) in a reactive porous medium. The experiments involved a water-saturated medium containing negatively charged, polyacrylamide beads, resembling many natural soils and aquifer materials, and having the same refraction index as water. Negatively and positively charged ENPs were injected into a uniform flow field in a 3-D horizontal flow cell, and the spatial and temporal concentrations of the evolving ENP plumes were obtained via image analysis. As a benchmark, and to calibrate the model, Congo red tracer was employed in 1-D column and 3-D flow cell experiments, containing the same beads. Negatively charged Au and Ag ENPs demonstrated migration patterns resembling those of the tracer but were slightly more dispersive; the transport was well represented by the CTRW-PT model. In contrast, positively charged AgNPs displayed an unusual behavior: establishment of an initial plume of essentially immobilized ENPs, followed by development of a secondary, freely migrating plume. The mobile plume was found to contain ENPs that, with aging, exhibited aggregation and charge inversion, becoming negatively charged and mobile. In this case, the CTRW-PT model was modified to include a probabilistic law for particle immobilization, to account for the decreasing tendency (over distance and time) of the positively charged AgNPs to attach to the porous medium. The agreement between experimental results and modeling suggests that the CTRW-PT framework can account for the non-Fickian and surface-charge-dependent transport and aging exhibited by ENPs in porous media.

  3. Spatiotemporal temperature fluctuation measurements by means of a fast swept Langmuir probe array.

    Science.gov (United States)

    Schubert, M; Endler, M; Thomsen, H

    2007-05-01

    Stationary Langmuir probe measurements of ion saturation current and floating potential in a plasma cannot give direct information on density and plasma potential fluctuations in the presence of temperature fluctuations. This problem can be avoided if the probe bias voltage is continuously swept faster than the fluctuation time scale, recording the current-voltage characteristic. This article reports the development of a spatiotemporal highly resolving Langmuir probe array with 15 fast swept tips, operating in the strongly magnetized, collisionless edge plasma of the Wendelstein 7-AS stellarator [Plasma Phys. Controlled Fusion 31, 1579 (1989)]. The probe tips are aligned in the poloidal direction, the tip spacing is 2 mm, and the sweeping frequency is 1.4 MHz. Current and voltage data are sampled with 50 MHz. The high bandwidth of the measurement is achieved by placing miniaturized differential amplifiers close to the probe tips in order to do an impedance transform. The surface-mounting technology and an additional inverse feedback module are utilized, allowing for an input voltage range of +/-100 V, and a common mode rejection rate of 55 dB at 4 MHz, which is sufficient to resolve the nonlinear probe characteristic. For the evaluation of the data, a fit model for stationary probes is employed and found adequate. Changes of the plasma parameters during one voltage sweep are taken into account by a linear interpolation of the fit parameters. Spatio-temporal fluctuation data gained by a fast swept Langmuir probe array, which can be relevant for the turbulent radial transport of particles and energy, are presented.

  4. Spatiotemporal temperature fluctuation measurements by means of a fast swept Langmuir probe array

    Science.gov (United States)

    Schubert, M.; Endler, M.; Thomsen, H.

    2007-05-01

    Stationary Langmuir probe measurements of ion saturation current and floating potential in a plasma cannot give direct information on density and plasma potential fluctuations in the presence of temperature fluctuations. This problem can be avoided if the probe bias voltage is continuously swept faster than the fluctuation time scale, recording the current-voltage characteristic. This article reports the development of a spatiotemporal highly resolving Langmuir probe array with 15 fast swept tips, operating in the strongly magnetized, collisionless edge plasma of the Wendelstein 7-AS stellarator [Plasma Phys. Controlled Fusion 31, 1579 (1989)]. The probe tips are aligned in the poloidal direction, the tip spacing is 2mm, and the sweeping frequency is 1.4MHz. Current and voltage data are sampled with 50MHz. The high bandwidth of the measurement is achieved by placing miniaturized differential amplifiers close to the probe tips in order to do an impedance transform. The surface-mounting technology and an additional inverse feedback module are utilized, allowing for an input voltage range of ±100V, and a common mode rejection rate of 55dB at 4MHz, which is sufficient to resolve the nonlinear probe characteristic. For the evaluation of the data, a fit model for stationary probes is employed and found adequate. Changes of the plasma parameters during one voltage sweep are taken into account by a linear interpolation of the fit parameters. Spatio-temporal fluctuation data gained by a fast swept Langmuir probe array, which can be relevant for the turbulent radial transport of particles and energy, are presented.

  5. Fast retinal vessel detection and measurement using wavelets and edge location refinement.

    Directory of Open Access Journals (Sweden)

    Peter Bankhead

    Full Text Available The relationship between changes in retinal vessel morphology and the onset and progression of diseases such as diabetes, hypertension and retinopathy of prematurity (ROP has been the subject of several large scale clinical studies. However, the difficulty of quantifying changes in retinal vessels in a sufficiently fast, accurate and repeatable manner has restricted the application of the insights gleaned from these studies to clinical practice. This paper presents a novel algorithm for the efficient detection and measurement of retinal vessels, which is general enough that it can be applied to both low and high resolution fundus photographs and fluorescein angiograms upon the adjustment of only a few intuitive parameters. Firstly, we describe the simple vessel segmentation strategy, formulated in the language of wavelets, that is used for fast vessel detection. When validated using a publicly available database of retinal images, this segmentation achieves a true positive rate of 70.27%, false positive rate of 2.83%, and accuracy score of 0.9371. Vessel edges are then more precisely localised using image profiles computed perpendicularly across a spline fit of each detected vessel centreline, so that both local and global changes in vessel diameter can be readily quantified. Using a second image database, we show that the diameters output by our algorithm display good agreement with the manual measurements made by three independent observers. We conclude that the improved speed and generality offered by our algorithm are achieved without sacrificing accuracy. The algorithm is implemented in MATLAB along with a graphical user interface, and we have made the source code freely available.

  6. On the fast electron beam, consequent generation of electrostatic fields and fast ion production in front of LH grills: Measurements and theory

    International Nuclear Information System (INIS)

    Petrzilka, V.; Zacek, F.; Kolman, B.

    2001-01-01

    The paper presents measurements of radial variations of the floating potential at the Tore Supra (TS) tokamak ergodic divertor plate and in front of the CASTOR tokamak lower hybrid (LH) grill, due to the presence in these two locations of the fast particle beam generated in front of LH grills. The paper also presents a scanning electron microscope (SEM) and secondary ion mass spectrometric (SIMS) analysis of an eroded graphite tile from the TS LH grill guard limiter, performed in order to check the authors' theoretical conclusion that fast ions can be generated in a thin layer in front of LH grills and that they can contribute to damage of tokamak vessel components. The paper first presents theoretical conclusions that are relevant to the experimental data and then the experimental results. (author)

  7. In situ resistance measurements of bronze process Nb-Sn-Cu-Ta multifilamentary composite conductors during reactive diffusion

    International Nuclear Information System (INIS)

    Tan, K S; Hopkins, S C; Glowacki, B A; Majoros, M; Astill, D

    2004-01-01

    The conditions under which the Nb 3 Sn intermetallic layer is formed by solid-state reactive diffusion processes in bronze process multifilamentary conductors greatly influence the performance of the conductors. By convention, isothermal heat treatment is used and often causes non-uniformity of A15 layers formed across the wire. Therefore, characterization and optimization of the conductor during the reactive diffusion processes is crucial in order to improve the overall conductor's performance. In this paper, a different characterization approach and perhaps an optimization technique is presented, namely in situ resistance measurement by an alternating current (AC) method. By treating the components of such multifilamentary wires as a set of parallel resistors, the resistances of the components may be combined using the usual rules for resistors in parallel. The results show that the resistivity of the entire wire changes significantly during the reactive diffusion processes. The development of the Nb 3 Sn layer in bronze process Nb-Sn-Cu-Ta multifilamentary wires at different stages of the reactive diffusion processes has been monitored using measured resistivity changes, and correlated with results from DTA, ACS, SEM and EDS

  8. Proactive, reactive, and romantic relational aggression in adulthood: measurement, predictive validity, gender differences, and association with Intermittent Explosive Disorder.

    Science.gov (United States)

    Murray-Close, Dianna; Ostrov, Jamie M; Nelson, David A; Crick, Nicki R; Coccaro, Emil F

    2010-04-01

    The psychometric properties of a recently introduced adult self-report of relational aggression are presented. Specifically, the predictive utility of proactive and reactive peer-directed relational aggression, as well as romantic relational aggression, are explored in a large (N=1387) study of adults. The measure had adequate reliability and validity and the subscales demonstrated unique predictive abilities for a number of dependent variables. In particular, reactive but not proactive relational aggression was uniquely associated with history of abuse, hostile attribution biases, and feelings of distress regarding relational provocation situations. Reactive relational aggression was also more strongly related to anger and hostility than proactive aggression. In addition, relational aggression in the context of romantic relationships was uniquely related to anger, hostility, impulsivity, history of abuse, hostile attribution biases, and emotional sensitivity to relational provocations, even when controlling for peer-directed relational aggression. Gender differences in overall levels of relational aggression were not observed; however, males were most likely to engage in peer-directed proactive and reactive relational aggression whereas females were most likely to engage in romantic relational aggression. In a second study (N=150), relational aggression was higher in a sample of adults with Intermittent Explosive Disorder than in a sample of healthy controls or psychiatric controls. The findings highlight the importance of assessing subtypes of relational aggression in adult samples. Ways in which this measure may extend research in psychology and psychiatry are discussed. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 58Ni(n,p)58Co. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 2.1 MeV and for irradiation times up to about 200 days in the absence of high thermal neutron fluence rates (for longer irradiations, see Practice E 261). 1.3 With suitable techniques fission-neutron fluence rates densities above 107 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note—The burnup corrections were com...

  10. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  11. Regular, Fast and Accurate Airborne In-Situ Methane Measurements Around the Tropopause

    Science.gov (United States)

    Dyroff, Christoph; Rauthe-Schöch, Armin; Schuck, Tanja J.; Zahn, Andreas

    2013-04-01

    We present a laser spectrometer for automated monthly measurements of methane (CH4) mixing ratios aboard the CARIBIC passenger aircraft. The instrument is based on a commercial fast methane analyzer (FMA, Los Gatos Res.), which was modified for fully unattended employment. A laboratory characterization was performed and the results with emphasis on the precision, cross sensitivity to H2O, and accuracy are presented. An in-flight calibration strategy is described, that utilizes CH4 measurements obtained from flask samples taken during the same flights. By statistical comparison of the in-situ measurements with the flask samples we derive a total uncetrainty estimate of ~ 3.85 ppbv (1?) around the tropopause, and ~ 12.4 ppbv (1?) during aircraft ascent and descent. Data from the first two years of airborne operation are presented that span a large part of the northern hemispheric upper troposphere and lowermost stratosphere, with occasional crossings of the tropics on flights to southern Africa. With its high spatial resolution and high accuracy this data set is unprecedented in the highly important atmospheric layer of the tropopause.

  12. A facility for measurements of nuclear cross sections for fast neutron cancer therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dangtip, S.; Atac, A.; Bergenwall, B.; Blomgren, J.; Elmgren, K.; Johansson, C.; Klug, J.; Olsson, N. E-mail: nils.olsson@tsl.uu.se; Carlsson, G. Alm; Soederberg, J.; Jonsson, O.; Nilsson, L.; Renberg, P.-U.; Nadel-Turonski, P.; Brun, C. Le; Lecolley, F.-R.; Lecolley, J.-F.; Varignon, C.; Eudes, Ph.; Haddad, F.; Kerveno, M.; Kirchner, T.; Lebrun, C

    2000-10-01

    A facility for measurements of neutron-induced double-differential light-ion production cross-sections, for application within, e.g., fast neutron cancer therapy, is described. The central detection elements are three-detector telescopes consisting of two silicon detectors and a CsI crystal. Use of {delta}E-{delta}E-E techniques allows good particle identification for p, d, t, {sup 3}He and alpha particles over an energy range from a few MeV up to 100 MeV. Active plastic scintillator collimators are used to define the telescope solid angle. Measurements can be performed using up to eight telescopes at 20 deg. intervals simultaneously, thus covering a wide angular range. The performance of the equipment is illustrated using experimental data taken with a carbon target at E{sub n}=95 MeV. Distortions of the measured charged-particle spectra due to energy and particle losses in the target are corrected using a newly developed computer code. Results from such correction calculations are presented.

  13. A facility for measurements of nuclear cross sections for fast neutron cancer therapy

    Science.gov (United States)

    Dangtip, S.; Ataç, A.; Bergenwall, B.; Blomgren, J.; Elmgren, K.; Johansson, C.; Klug, J.; Olsson, N.; Carlsson, G. A.; Söderberg, J.; Jonsson, O.; Nilsson, L.; Renberg, P.-U.; Nadel-Turonski, P.; Brun, C. L.; Lecolley, F.-R.; Lecolley, J.-F.; Varignon, C.; Eudes, P.; Haddad, F.; Kerveno, M.; Kirchner, T.; Lebrun, C.

    2000-10-01

    A facility for measurements of neutron-induced double-differential light-ion production cross-sections, for application within, e.g., fast neutron cancer therapy, is described. The central detection elements are three-detector telescopes consisting of two silicon detectors and a CsI crystal. Use of /ΔE-ΔE-E techniques allows good particle identification for p, d, t, 3He and alpha particles over an energy range from a few MeV up to 100 MeV. Active plastic scintillator collimators are used to define the telescope solid angle. Measurements can be performed using up to eight telescopes at /20° intervals simultaneously, thus covering a wide angular range. The performance of the equipment is illustrated using experimental data taken with a carbon target at En=95 MeV. Distortions of the measured charged-particle spectra due to energy and particle losses in the target are corrected using a newly developed computer code. Results from such correction calculations are presented.

  14. Scatterometry—fast and robust measurements of nano-textured surfaces

    Science.gov (United States)

    Hannibal Madsen, Morten; Hansen, Poul-Erik

    2016-06-01

    Scatterometry is a fast, precise and low cost way to determine the mean pitch and dimensional parameters of periodic structures with lateral resolution of a few nanometer. It is robust enough for in-line process control and precise and accurate enough for metrology measurements. Furthermore, scatterometry is a non-destructive technique capable of measuring buried structures, for example a grating covered by a thick oxide layer. As scatterometry is a non-imaging technique, mathematical modeling is needed to retrieve structural parameters that describe a surface. In this review, the three main steps of scatterometry are discussed: the data acquisition, the simulation of diffraction efficiencies and the comparison of data and simulations. First, the intensity of the diffracted light is measured with a scatterometer as a function of incoming angle, diffraction angle and/or wavelength. We discuss the evolution of the scatterometers from the earliest angular scatterometers to the new imaging scatterometers. The basic principle of measuring diffraction efficiencies in scatterometry has remained the same since the beginning, but the instrumental improvements have made scatterometry a state-of-the-art solution for fast and accurate measurements of nano-textured surfaces. The improvements include extending the wavelength range from the visible to the extreme ultra-violet range, development of Fourier optics to measure all diffraction orders simultaneously, and an imaging scatterometer to measure area of interests smaller than the spot size. Secondly, computer simulations of the diffraction efficiencies are discussed with emphasis on the rigorous coupled-wave analysis (RCWA) method. RCWA has, since the mid-1990s, been the preferred method for grating simulations due to the speed of the algorithms. In the beginning the RCWA method suffered from a very slow convergence rate, and we discuss the historical improvements to overcome this challenge, e.g. by the introduction of Li

  15. Benchmark and combined velocity-space tomography of fast-ion D-alpha spectroscopy and collective Thomson scattering measurements

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko; Geiger, B.

    2016-01-01

    measurements without using a numerical simulation as common reference. Combined velocity-space tomographies from FIDA and CTS measurements confirm that sawtooth crashes reduce the fast-ion phase-space densities in the plasma center and affect ions with pitches close to one more strongly than those with pitches......We demonstrate the combination of fast-ion D-alpha spectroscopy (FIDA) and collective Thomson scattering (CTS) measurements to determine a common best estimate of the fastion velocity distribution function by velocity-space tomography. We further demonstrate a benchmark of FIDA tomography and CTS...

  16. A new Recoil Proton Telescope for energy and fluence measurement of fast neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Lebreton, Lena; Bachaalany, Mario [IRSN / LMDN (Institut de Radioprotection et de Surete nucleaire / Laboratoire de Metrologie et de dosimetrie des neutrons), Cadarache Bat.159, 13115 Saint Paul-lez-Durance, (France); Husson, Daniel; Higueret, Stephane [IPHC / RaMsEs (Institut Pluridisciplinaire Hubert Curien / Radioprotection et Mesures Environnementales), 23 rue du loess - BP28, 67037 Strasbourg cedex 2, (France)

    2015-07-01

    The spectrometer ATHENA (Accurate Telescope for High Energy Neutron metrology Applications), is being developed at the IRSN / LMDN (Institut de Radioprotection et de Surete nucleaire / Laboratoire de Metrologie et de dosimetrie des neutrons) and aims at characterizing energy and fluence of fast neutron fields. The detector is a Recoil Proton Telescope and measures neutron fields in the range of 5 to 20 MeV. This telescope is intended to become a primary standard for both energy and fluence measurements. The neutron detection is achieved by a polyethylene radiator for n-p conversion, three 50{sub m} thick silicon sensors that use CMOS technology for the proton tracking and a 3 mm thick silicon diode to measure the residual proton energy. This first prototype used CMOS sensors called MIMOSTAR, initially developed for heavy ion physics. The use of CMOS sensors and silicon diode increases the intrinsic efficiency of the detector by a factor of ten compared with conventional designs. The first prototype has already been done and was a successful study giving the results it offered in terms of energy and fluence measurements. For mono energetic beams going from 5 to 19 MeV, the telescope offered an energy resolution between 5 and 11% and fluence difference going from 5 to 7% compared to other home standards. A second and final prototype of the detector is being designed. It will hold upgraded CMOS sensors called FastPixN. These CMOS sensors are supposed to run 400 times faster than the older version and therefore give the telescope the ability to support neutron flux in the order of 107 to 108cm{sup 2}:s{sup 1}. The first prototypes results showed that a 50 m pixel size is enough for a precise scattering angle reconstruction. Simulations using MCNPX and GEANT4 are already in place for further improvements. A DeltaE diode will replace the third CMOS sensor and will be installed right before the silicon diode for a better recoil proton selection. The final prototype with

  17. FEASIBILITY OF MEASURING IRON IN VIVO USING FAST 14 MEV NEUTRONS.

    Energy Technology Data Exchange (ETDEWEB)

    WIELOPOLSKI, L.

    2005-05-01

    In this short report, I reassess the feasibility of measuring iron in vivo in the liver and heart of thalassemia patients undergoing chelation therapy. Despite the multiplicity of analytical methods for analyzing iron, only two, magnetic resonance imaging, and magnetic susceptibility, are suitable for in vivo applications, and these are limited to the liver because of the heart's beat. Previously, a nuclear method, gamma-resonance scattering, offered a quantitative measure of iron in these organs; however, it was abandoned because it necessitated a nuclear reactor to produce the radioactive source. I reviewed and reassessed the status of two alternative nuclear methods, based on iron spectroscopy of gamma rays induced by fast neutron inelastic scattering and delayed activation in iron. Both are quantitative methods with high specificity for iron and adequate penetrating power to measure it in organs sited deep within the human body. My experiments demonstrated that both modalities met the stated qualitative objectives to measure iron. However, neutron dosimetry revealed that the intensity of the neutron radiation field was too weak to reliably assess the minimum detection limits, and to allow quantitative extrapolations to measurements in people. A review of the literature, included in this report, showed that these findings agree qualitatively with the published results, although the doses reported were about three orders-of-magnitude higher than those I used. Reviewing the limitations of the present work, steps were outlined for overcoming some of the shortcomings. Due to a dearth of valid quantitative alternatives for determining iron in vivo, I conclude that nuclear methods remain the only viable option. However, from the lessons learned, further systematic work is required before embarking on clinical studies.

  18. Fast charge digitizer and digital data acquisition system for measuring time varying radiation fields

    International Nuclear Information System (INIS)

    Lee, T.R.; Schneider, R.H.; Wyatt, J.L.

    1976-01-01

    A radiation measuring instrument including a fast charge digitizer and a digital data acquisition system has been developed. The fast charge digitizer includes a charge integrator connected to a conventional ionization chamber which generates an output current in proportion to ionizing radiation exposure rate. The charge integrator has an output connected to a comparator which is switched from a high state to a low state when the output of the integrator goes above the comparator threshold. The comparator output is connected to a bistable multivibrator consisting of two non-retriggerable one shot multivibrators connected in a feedback configuration. As long as the comparator output is in the low state, the bistable multivibrator generates a train of pluses which are fed back through an analog switch and a high megohm resistance to the input of the integrator. This feedback is negative and has the effect of removing the charge from the integrating capacitor, thus causing the integrator output eventually to drop below the comparator threshold. When this occurs the comparator output returns to the high state and the bistable multivibrator ceases to generate output pulses. An output terminal is connected between the bistable multivibrator and the analog switch and feeds a train of pulses proportional to the amount of charge generated by the multivibrator output voltage and the high megohm resistance to a counter connected to a random access memory device. The output pulses are counted for a predetermined time and then stored in one of the data locations of the random access memory device. The counter is then reset and a further predetermined sample period is counted. This continues until all of the locations in the random access memory device are filled and then the data is read from the random access memory device

  19. Fast measurement by infrared spectroscopy as support to woody biofuels quality determination

    Directory of Open Access Journals (Sweden)

    Daniele Duca

    2016-03-01

    Full Text Available The increase in the demand for energy supply during the past few decades has brought and will bring to a growth in the utilisation of renewable resources, in particular of solid biomasses. Considering the variability in the properties of biomass and the globalisation of the timber market, a chemical and physical characterisation is essential to determine the biomass quality. The specific international standards on solid biofuels (ISO 17225 series describe proper specification and classification of wood chip and pellet, to ensure appropriate quality. Moreover, standard requires information about origin and source of the biomass, normally only to be declared by the producers. In order to fulfill the requirements for the biomass quality, the origin and the source should be assessed, even if currently is hard to determine, in particular on milled or densified biomass. Infrared spectroscopy can provide information on the biomass at the chemical level, directly linked also to its origin and source. This technique is fast and not destructive thus suitable also for online monitoring along the biofuel production chain. In this study, 60 samples belonging to 8 different species were collected and related spectra were acquired using a Fourier transform infrared (IR spectrometer equipped with a module for solid analysis and analysed by principal component analysis. The results obtained show that the method is very efficient in the identification between coniferous and deciduous wood (99% confidence level and good results were obtained in the recognition of coniferous/deciduous mixtures, too. Nevertheless, some clear differences have been also noted among intra-class grouping, but additional tests should be carried out. This technique can provide useful information to solid biofuel stakeholders about wood quality and origin, important especially for sustainability issues. Further work will be oriented to the development of IR methodologies for the fast

  20. Measurements of the fast ion distribution during neutral beam injection and ion cyclotron heating in ATF [Advanced Toroidal Facility

    International Nuclear Information System (INIS)

    Wade, M.R.; Kwon, M.; Thomas, C.E.; Colchin, R.J.; England, A.C.; Gossett, J.M.; Horton, L.D.; Isler, R.C.; Lyon, J.F.; Rasmussen, D.A.; Rayburn, T.M.; Shepard, T.D.; Bell, G.L.; Fowler, R.H.; Morris, R.N.

    1990-01-01

    A neutral particle analyzer (NPA) with horizontal and vertical scanning capability has been used to make initial measurements of the fast ion distribution during neutral beam injection (NBI) and ion cyclotron heating (ICH) on the Advanced Toroidal Facility (ATF). These measurements are presented and compared with the results of modeling codes that predict the analyzer signals during these heating processes. 6 refs., 5 figs

  1. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 158B/159A

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walker, Billy Justin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-11-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 158B/159A which were measured by the Radiation Measurements Laboratory (RML).

  2. Fast-scanning heterodyne receiver for measurement of the electron cyclotron emission from high-temperature plasmas

    International Nuclear Information System (INIS)

    Efthimion, P.C.; Arunasalam, V.; Bitzer, R.; Campbell, L.; Hosea, J.C.

    1979-03-01

    A fast-scanning heterodyne receiver was developed that measures the fundamental cyclotron emission from the PLT plasma and thus ascertains the time evolution of the electron temperature profile. The receiver scans 60 to 90 GHz every 10 milliseconds and is interfaced to a computer for completely automated calibrated temperature measurements

  3. Fast ion dynamics in ASDEX upgrade and TEXTOR measured by collective Thomson scattering

    International Nuclear Information System (INIS)

    Moseev, D.

    2011-11-01

    Fast ions are an essential ingredient in burning nuclear fusion plasmas: they are responsible for heating the bulk plasma, carry a significant amount of plasma current and moreover interact with various magnetohydrodynamic (MHD) instabilities. The collective Thomson scattering (CTS) diagnostic is sensitive to the projection of fast ion velocity distribution function. This thesis is mainly devoted to investigations of fast ion physics in tokamak plasmas by means of CTS. (Author)

  4. Fast ion dynamics in ASDEX upgrade and TEXTOR measured by collective Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Moseev, D.

    2011-11-15

    Fast ions are an essential ingredient in burning nuclear fusion plasmas: they are responsible for heating the bulk plasma, carry a significant amount of plasma current and moreover interact with various magnetohydrodynamic (MHD) instabilities. The collective Thomson scattering (CTS) diagnostic is sensitive to the projection of fast ion velocity distribution function. This thesis is mainly devoted to investigations of fast ion physics in tokamak plasmas by means of CTS. (Author)

  5. QUALITATIVE MEASUREMENTS OF IGE AND IGG IN HUMAN ASTHMATIC SERUM FOR MOLD REACTIVITY

    Science.gov (United States)

    Rational: Molds have the ability to induce allergic asthma-like responses in mouse models; however, their role in human disease is unclear. This study was to develop a screening tool for reactivity of human sera to mold extracts by using a minimal amount of sera for a qual...

  6. Measuring Physical Activity with Pedometers in Older Adults with Intellectual Disability : Reactivity and Number of Days

    NARCIS (Netherlands)

    Hilgenkamp, Thessa; Van Wijck, Ruud; Evenhuis, Heleen

    The minimum number of days of pedometer monitoring needed to estimate valid average weekly step counts and reactivity was investigated for older adults with intellectual disability. Participants (N = 268) with borderline to severe intellectual disability ages 50 years and older were instructed to

  7. Scintillation spectrometer system for measuring fast-neutron spectra in beam geometry

    International Nuclear Information System (INIS)

    Simons, G.G.; Larson, J.M.; Reynolds, R.S.

    1977-05-01

    A high-energy liquid-organic scintillation spectrometer system is described. This spectrometer was developed to measure neutron spectra in extracted beams from zero-power fast reactors. The highly efficient NE-213 scintillation solution was used as the neutron detection medium. Identification and removal of gamma-ray-induced events was accomplished using electronic pulse shape discrimination. Instrumentation used to process the discrete pulses stemming from neutron and gamma-ray interactions, within the scintillation solution, is described in detail. Evaluation of the system's performance is discussed for a gamma-ray discrimination ratio of nominally 1000:1, a total countrate of 3000 cps, and a dynamic range corresponding to neutron energies from 1 to 10 MeV. Operation above 10 MeV is certainly possible. However, since the neutron flux above 10 MeV was negligible in the radiation fields of interest in this work, the operating characteristics of the spectrometer were not evaluated above 10 MeV. Neutron spectra are reported for extracted beam measurements made on ZPPR assembly 4, phase 2

  8. ALE3D Simulation and Measurement of Violence in a Fast Cookoff Experiment with LX-10

    Energy Technology Data Exchange (ETDEWEB)

    McClelland, M A; Maienschein, J L; Howard, W M; deHaven, M R

    2006-11-22

    We performed a computational and experimental analysis of fast cookoff of LX-10 (94.7% HMX, 5.3% Viton A) confined in a 2 kbar steel tube with reinforced end caps. A Scaled-Thermal-Explosion-eXperiment (STEX) was completed in which three radiant heaters were used to heat the vessel until ignition, resulting in a moderately violent explosion after 20.4 minutes. Thermocouple measurements showed tube temperatures as high as 340 C at ignition and LX-10 surface temperatures as high as 279 C, which is near the melting point of HMX. Three micro-power radar systems were used to measure mean fragment velocities of 840 m/s. Photonics Doppler Velocimeters (PDVs) showed a rapid acceleration of fragments over 80 {micro}s. A one-dimensional ALE3D cookoff model at the vessel midplane was used to simulate the heating, thermal expansion, LX-10 decomposition composition, and closing of the gap between the HE (High Explosive) and vessel wall. Although the ALE3D simulation terminated before ignition, the model provided a good representation of heat transfer through the case and across the dynamic gap to the explosive.

  9. Rapid measurement of residual dipolar couplings for fast fold elucidation of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Rasia, Rodolfo M. [Jean-Pierre Ebel CNRS/CEA/UJF, Institut de Biologie Structurale (France); Lescop, Ewen [CNRS, Institut de Chimie des Substances Naturelles (France); Palatnik, Javier F. [Universidad Nacional de Rosario, Instituto de Biologia Molecular y Celular de Rosario, Facultad de Ciencias Bioquimicas y Farmaceuticas (Argentina); Boisbouvier, Jerome, E-mail: jerome.boisbouvier@ibs.fr; Brutscher, Bernhard, E-mail: Bernhard.brutscher@ibs.fr [Jean-Pierre Ebel CNRS/CEA/UJF, Institut de Biologie Structurale (France)

    2011-11-15

    It has been demonstrated that protein folds can be determined using appropriate computational protocols with NMR chemical shifts as the sole source of experimental restraints. While such approaches are very promising they still suffer from low convergence resulting in long computation times to achieve accurate results. Here we present a suite of time- and sensitivity optimized NMR experiments for rapid measurement of up to six RDCs per residue. Including such an RDC data set, measured in less than 24 h on a single aligned protein sample, greatly improves convergence of the Rosetta-NMR protocol, allowing for overnight fold calculation of small proteins. We demonstrate the performance of our fast fold calculation approach for ubiquitin as a test case, and for two RNA-binding domains of the plant protein HYL1. Structure calculations based on simulated RDC data highlight the importance of an accurate and precise set of several complementary RDCs as additional input restraints for high-quality de novo structure determination.

  10. Membrane solubilization in erythrocytes as a measure of radiation exposure to fast neutrons

    International Nuclear Information System (INIS)

    Soltan Monem, A.; Ali, F.M.; Ali, S.A.; Al-thani, N.J.J.

    1999-01-01

    Membrane solubilization and osmotic fragility of rat erythrocytes irradiated in vivo with fast neutron fluences ranging from 10 6 to 5x10 7 n cm -2 using a 252 Cf source were measured instantaneously using a light scattering technique. The solubilization of erythrocyte membrane by a non-ionic detergent, octylglucoside (OG), was found to exhibit a two stage transition from vesicular form to mixed micellar form in the range of detergent concentrations 1.5-7.8 mM. The coexistence phase, vesicular/mixed micellar, was shifted towards higher detergent concentrations with increase in the neutron fluence, indicating increasing membrane resistance to the detergent and hence change in the natural membrane permeation properties. The technique shows an adequate sensitivity in detecting membrane damage in erythrocytes and has potential as a biophysical marker of radiation exposure. The osmotic fragility of irradiated erythrocytes shows a decreasing trend with increasing irradiation fluence measured directly and two weeks post-irradiation. Blood films photographed two weeks post-irradiation show developed elliptocytosis and crenated cell anaemia. (author)

  11. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    Science.gov (United States)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  12. Fast-turnaround alkyl nitrate measurements during the PROPHET 1998 summer intensive

    Science.gov (United States)

    Ostling, Kristi; Kelly, Brendan; Bird, Stephen; Bertman, Steven; Pippin, Margaret; Thornberry, Troy; Carroll, Mary Anne

    2001-10-01

    An automated gas chromatographic system for making fast-turnaround measurements of alkyl nitrates was developed and tested. Every 30 min, samples were automatically acquired on a 1/16-inch OD Tenax trap made from fused silica-lined stainless steel tubing and injected by thermal desorption into the gas chromatograph. The system exhibited good chromatographic resolution, minimal breakthrough, and on-trap stability for C3-C5 nitrates. The detection limit of the instrument was Biological Station in northern Michigan during the summer of 1998 from July 15 to August 22. Ambient results show a significant dynamic range with absolute levels affected by air mass history and pollution sources. The sum of measured C3-C5 alkyl nitrates obtained during this intensive ranged from 3.45 to 65.8 pptv, with a mean of 18.6 pptv and contributed 1% on average to total NOy, with a range of 0.5% to 3%. Differences in the contribution to NOy are found when the data are filtered according to air mass origin. A positive relationship between n-propyl nitrate and peroxypropionyl nitrate was observed over the course of the intensive.

  13. Rapid measurement of residual dipolar couplings for fast fold elucidation of proteins

    International Nuclear Information System (INIS)

    Rasia, Rodolfo M.; Lescop, Ewen; Palatnik, Javier F.; Boisbouvier, Jérôme; Brutscher, Bernhard

    2011-01-01

    It has been demonstrated that protein folds can be determined using appropriate computational protocols with NMR chemical shifts as the sole source of experimental restraints. While such approaches are very promising they still suffer from low convergence resulting in long computation times to achieve accurate results. Here we present a suite of time- and sensitivity optimized NMR experiments for rapid measurement of up to six RDCs per residue. Including such an RDC data set, measured in less than 24 h on a single aligned protein sample, greatly improves convergence of the Rosetta-NMR protocol, allowing for overnight fold calculation of small proteins. We demonstrate the performance of our fast fold calculation approach for ubiquitin as a test case, and for two RNA-binding domains of the plant protein HYL1. Structure calculations based on simulated RDC data highlight the importance of an accurate and precise set of several complementary RDCs as additional input restraints for high-quality de novo structure determination.

  14. Measurement control design and performance assessment in the Integral Fast Reactor fuel cycle

    International Nuclear Information System (INIS)

    Orechwa, Y.; Bucher, R.G.

    1994-01-01

    The Integral Fast Reactor (IFR)--consisting of a metal fueled and liquid metal cooled reactor together with an attendant fuel cycle facility (FCF)--is currently undergoing a phased demonstration of the closed fuel cycle at Argonne National Laboratory. The recycle technology is pyrometalurgical based with incomplete fission product separation and all transuranics following plutonium for recycle. The equipment operates in batch mode at 500 to 1,300 C. The materials are highly radioactive and pyrophoric, thus the FCF requires remote operation. Central to the material control and accounting system for the FCF are the balances for mass measurements. The remote operation of the balances limits direct adjustment. The radiation environment requires that removal and replacement of the balances be minimized. The uniqueness of the facility precludes historical data for design and performance assessment. To assure efficient operation of the facility, the design of the measurement control system has called for procedures which assess the performance of the balances in great detail and will support capabilities for the correction of systematic changes in the performance of the balances through software

  15. Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhijin [Univ. of California, Los Angeles, CA (United States); Sha, Feng [Univ. of California, Los Angeles, CA (United States); Liu, Yangang [Brookhaven National Lab. (BNL), Upton, NY (United States); Lin, Wuyin [Brookhaven National Lab. (BNL), Upton, NY (United States); Toto, Tami [Brookhaven National Lab. (BNL), Upton, NY (United States); Vogelmann, Andrew [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-02-02

    This five-year award supports the project “Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements (FASTER)”. The goal of this project is to produce accurate, consistent and comprehensive data sets for initializing both single column models (SCMs) and cloud resolving models (CRMs) using data assimilation. A multi-scale three-dimensional variational data assimilation scheme (MS-3DVAR) has been implemented. This MS-3DVAR system is built on top of WRF/GSI. The Community Gridpoint Statistical Interpolation (GSI) system is an operational data assimilation system at the National Centers for Environmental Prediction (NCEP) and has been implemented in the Weather Research and Forecast (WRF) model. This MS-3DVAR is further enhanced by the incorporation of a land surface 3DVAR scheme and a comprehensive aerosol 3DVAR scheme. The data assimilation implementation focuses in the ARM SGP region. ARM measurements are assimilated along with other available satellite and radar data. Reanalyses are then generated for a few selected period of time. This comprehensive data assimilation system has also been employed for other ARM-related applications.

  16. Measurement of fast-changing low velocities by photonic Doppler velocimetry.

    Science.gov (United States)

    Song, Hongwei; Wu, Xianqian; Huang, Chenguang; Wei, Yangpeng; Wang, Xi

    2012-07-01

    Despite the increasing popularity of photonic Doppler velocimetry (PDV) in shock wave experiments, its capability of capturing low particle velocities while changing rapidly is still questionable. The paper discusses the performance of short time Fourier transform (STFT) and continuous wavelet transform (CWT) in processing fringe signals of fast-changing low velocities measured by PDV. Two typical experiments are carried out to evaluate the performance. In the laser shock peening test, the CWT gives a better interpretation to the free surface velocity history, where the elastic precursor, main plastic wave, and elastic release wave can be clearly identified. The velocities of stress waves, Hugoniot elastic limit, and the amplitude of shock pressure induced by laser can be obtained from the measurement. In the Kolsky-bar based tests, both methods show validity of processing the longitudinal velocity signal of incident bar, whereas CWT improperly interprets the radial velocity of the shocked sample at the beginning period, indicating the sensitiveness of the CWT to the background noise. STFT is relatively robust in extracting waveforms of low signal-to-noise ratio. Data processing method greatly affects the temporal resolution and velocity resolution of a given fringe signal, usually CWT demonstrates a better local temporal resolution and velocity resolution, due to its adaptability to the local frequency, also due to the finer time-frequency product according to the uncertainty principle.

  17. A Fast, Locally Adaptive, Interactive Retrieval Algorithm for the Analysis of DIAL Measurements

    Science.gov (United States)

    Samarov, D. V.; Rogers, R.; Hair, J. W.; Douglass, K. O.; Plusquellic, D.

    2010-12-01

    Differential absorption light detection and ranging (DIAL) is a laser-based tool which is used for remote, range-resolved measurement of particular gases in the atmosphere, such as carbon-dioxide and methane. In many instances it is of interest to study how these gases are distributed over a region such as a landfill, factory, or farm. While a single DIAL measurement only tells us about the distribution of a gas along a single path, a sequence of consecutive measurements provides us with information on how that gas is distributed over a region, making DIAL a natural choice for such studies. DIAL measurements present a number of interesting challenges; first, in order to convert the raw data to concentration it is necessary to estimate the derivative along the path of the measurement. Second, as the distribution of gases across a region can be highly heterogeneous it is important that the spatial nature of the measurements be taken into account. Finally, since it is common for the set of collected measurements to be quite large it is important for the method to be computationally efficient. Existing work based on Local Polynomial Regression (LPR) has been developed which addresses the first two issues, but the issue of computational speed remains an open problem. In addition to the latter, another desirable property is to allow user input into the algorithm. In this talk we present a novel method based on LPR which utilizes a variant of the RODEO algorithm to provide a fast, locally adaptive and interactive approach to the analysis of DIAL measurements. This methodology is motivated by and applied to several simulated examples and a study out of NASA Langley Research Center (LaRC) looking at the estimation of aerosol extinction in the atmosphere. A comparison study of our method against several other algorithms is also presented. References Chaudhuri, P., Marron, J.S., Scale-space view of curve estimation, Annals of Statistics 28 (2000) 408-428. Duong, T., Cowling

  18. Validation of commercially available automated canine-specific immunoturbidimetric method for measuring canine C-reactive protein

    DEFF Research Database (Denmark)

    Hillström, Anna; Hagman, Ragnvi; Tvedten, Harold

    2014-01-01

    BACKGROUND: Measurement of C-reactive protein (CRP) is used for diagnosing and monitoring systemic inflammatory disease in canine patients. An automated human immunoturbidimetric assay has been validated for measuring canine CRP, but cross-reactivity with canine CRP is unpredictable. OBJECTIVE......: The purpose of the study was to validate a new automated canine-specific immunoturbidimetric CRP method (Gentian cCRP). METHODS: Studies of imprecision, accuracy, prozone effect, interference, limit of quantification, and stability under different storage conditions were performed. The new method was compared...... was detected at a concentration of 1200 mg/L. Recovery after spiking serum with purified canine CRP at 2 different concentrations was 123% and 116%, respectively. No interference from hemoglobin or triglycerides (10 g/L) was detected. CRP was stable for 14 days at 4°C and 22°C. In the method comparison study...

  19. Identifying fast-food restaurants using a central register as a measure of the food environment

    DEFF Research Database (Denmark)

    Toft, Ulla; Erbs-Maibing, Peter; Glümer, Charlotte

    2011-01-01

    To validate the identification and location of fast-food restaurants according to a government list of inspected food stores and restaurants.......To validate the identification and location of fast-food restaurants according to a government list of inspected food stores and restaurants....

  20. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering

    DEFF Research Database (Denmark)

    Bindslev, H.; Nielsen, S.K.; Porte, L.

    2006-01-01

    and ion cyclotron resonance heating. The temporal behavior of the spatially resolved fast-ion velocity distribution is inferred from the received scattered radiation. The fast-ion dynamics at sawteeth and the slowdown after switch off of auxiliary heating is resolved in time. The latter is shown...

  1. Soft x-ray continuum radiation transmitted through metallic filters: An analytical approach to fast electron temperature measurements

    International Nuclear Information System (INIS)

    Delgado-Aparicio, L.; Hill, K.; Bitter, M.; Tritz, K.; Kramer, T.; Stutman, D.; Finkenthal, M.

    2010-01-01

    A new set of analytic formulas describes the transmission of soft x-ray continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler et al., Rev. Sci. Instrum. 70, 599 (1999)]. The new analytic formulas can improve the interpretation of the experimental results and thus contribute in obtaining fast temperature measurements in between intermittent Thomson scattering data.

  2. A compact, fast UV photometer for measurement of ozone from research aircraft

    Directory of Open Access Journals (Sweden)

    R. S. Gao

    2012-09-01

    Full Text Available In situ measurements of atmospheric ozone (O3 are performed routinely from many research aircraft platforms. The most common technique depends on the strong absorption of ultraviolet (UV light by ozone. As atmospheric science advances to the widespread use of unmanned aircraft systems (UASs, there is an increasing requirement for minimizing instrument space, weight, and power while maintaining instrument accuracy, precision and time response. The design and use of a new, dual-beam, UV photometer instrument for in situ O3 measurements is described. A polarization optical-isolator configuration is utilized to fold the UV beam inside the absorption cells, yielding a 60-cm absorption length with a 30-cm cell. The instrument has a fast sampling rate (2 Hz at <200 hPa, 1 Hz at 200–500 hPa, and 0.5 Hz at ≥ 500 hPa, high accuracy (3% excluding operation in the 300–450 hPa range, where the accuracy may be degraded to about 5%, and excellent precision (1.1 × 1010 O3 molecules cm−3 at 2 Hz, which corresponds to 3.0 ppb at 200 K and 100 hPa, or 0.41 ppb at 273 K and 1013 hPa. The size (36 l, weight (18 kg, and power (50–200 W make the instrument suitable for many UASs and other airborne platforms. Inlet and exhaust configurations are also described for ambient sampling in the troposphere and lower stratosphere (1000–50 hPa that control the sample flow rate to maximize time response while minimizing loss of precision due to induced turbulence in the sample cell. In-flight and laboratory intercomparisons with existing O3 instruments show that measurement accuracy is maintained in flight.

  3. Measuring the radial density distribution of light emission around the track of fast ions in nitrogen

    International Nuclear Information System (INIS)

    Ibach, T.

    1983-01-01

    For analysing the emission and stopping of ionization electrons (σ-electrons) emitted by fast ions passing through a gas, the radial density distribution of the light emission of the (0,0) transition of two optical bands in nitrogen have been measured. The systems selected for the epxeriments are the 2nd positive system (2.PS) at 337.1 nm primarily excited by low-energy electrons of about 20 eV, and the first negative system (1.NS) at 391.4 nm excited by faster electrons and simultaneous ionization. The equipment developed for the experiments records the light emission with a telescope-type optical arrangement including interference filters, allowing high local resolution and dynamics of the measured range. The measurements have been carried out at pressures between 0.133 and 13.3 mbar, using photons of energies ranging from 270 keV to 2.8 MeV, helium 3 beams of 270 keV/u and 500 keV/u, and neon beams of 270 keV/u. Abel's inversion applied to the distance functions allows calculation of the spatial light emission density which is normalized for a gas density of 1 g/cm 3 . The profiles of the two bands indicate that the σ-electron spectrum gets harder in outward direction. Next to the beam the impact density decreases faster with increasing ion energy than the stopping power (increasing interaction range of the σ-electrons). With photon beams, about half of the whole light emission in the 1. NS, and of the ionization, is induced by primary interactions of the ion beam. This proportion decreases at constant energy per nucleon with increasing atomic number of the ions as compared with the σ-electrons. The primary σ-emission gets harder with higher atomic numbers. (orig./HP) [de

  4. Development of a fast method for quantitative measurement of hyperpolarized 129Xe dynamics in mouse brain.

    Science.gov (United States)

    Imai, Hirohiko; Kimura, Atsuomi; Akiyama, Kazue; Ota, Chikako; Okimoto, Kazuki; Fujiwara, Hideaki

    2012-02-01

    A fast method has been established for the precise measurement and quantification of the dynamics of hyperpolarized (HP) xenon-129 ((129)Xe) in the mouse brain. The key technique is based on repeatedly applying radio frequency (RF) pulses and measuring the decrease of HP (129)Xe magnetization after the brain Xe concentration has reached a steady state due to continuous HP (129)Xe ventilation. The signal decrease of the (129)Xe nuclear magnetic resonance (NMR) signal was well described by a simple theoretical model. The technique made it possible to rapidly evaluate the rate constant α, which is composed of cerebral blood flow (CBF), the partition coefficient of Xe between the tissue and blood (λ(i)), and the longitudinal relaxation time (T(1i)) of HP (129)Xe in the brain tissue, without any effect of depolarization by RF pulses and the dynamics in the lung. The technique enabled the precise determination of α as 0.103 ± 0.018  s(-1) (± SD, n = 5) on healthy mice. To investigate the potential of this method for detecting physiological changes in the brain of a kainic acid (KA) -induced mouse model of epilepsy, an attempt was made to follow the time course of α after KA injection. It was found that the α value changes characteristically with time, reflecting the change in the physiological state of the brain induced by KA injection. By measuring CBF using (1)H MRI and (129)Xe dynamics simultaneously and comparing these results, it was suggested that the reduction of T(1i), in addition to the increase of CBF due to KA-induced epilepsy, are possible causes of the change in (129)Xe dynamics. Thus, the present method would be useful to detect a pathophysiological state in the brain and provide a novel tool for future brain study. Copyright © 2011 John Wiley & Sons, Ltd.

  5. In-situ measurements of ice nucleating particles with FINCH (Fast Ice Nucleus Chamber)

    Science.gov (United States)

    Kohl, Rebecca; Frank, Fabian; Curtius, Joachim; Rose, Diana

    2017-04-01

    Ice nucleating particles (INPs), which are a small fraction of the total aerosol population, are capable of triggering ice formation under atmospheric conditions. Since INPs play an important role for the radiative properties of clouds as well as for the formation of precipitation it is important to get quantitative information on the ice activity of various atmospheric aerosol species. With the Fast Ice Nucleus Chamber (FINCH; Bundke et al., 2008) the number concentration of INP is determined at different freezing temperatures and supersaturations. In contrast to other commonly used INP counters, i.e., continuous flow diffusion chambers (CFDCs, DeMott et al., 2011), in FINCH the supersaturation is reached by mixing the sample flow of ambient aerosol with a warm moist as well as a cold dry airflow. By changing the flow rates and temperatures of the individual airflows the freezing temperature (down to -50°C) and supersaturation (up to above water saturation) can be varied relatively quickly. Particles that are ice active at the prescribed freezing temperature and supersaturation grow to crystals and are counted by a home-built optical particle counter (OPC) mounted below the chamber (Bundke et al., 2010). FINCH was operated during the four-week INUIT-BACCHUS-ACTRIS field campaign in Cyprus in April 2016. The measuring site was the location of the Cyprus Atmospheric Observatory (CAO) at Agia Marina Xyliatou, which is typically influenced by dust from the Sahara and the Middle East, an aerosol that is known to have relatively good ice nucleating ability. First results from this campaign will be presented. Acknowledgements: The authors thank the entire INUIT-BACCHUS-ACTRIS campaign team for their cooperation and support. The INUIT-2 project is financed by the German Research Foundation DFG (FOR 1525). The INUIT-Cyprus campaign is a cooperation with the EU-funded project BACCHUS and is also funded by ACTRIS-TNA. References: Bundke, U., Nillius, B., Jaenicke, R

  6. Experimental measurement and modelling of reactive species generation in TiO2 nanoparticle photocatalysis.

    Science.gov (United States)

    Turolla, Andrea; Piazzoli, Andrea; Budarz, Jeffrey Farner; Wiesner, Mark R; Antonelli, Manuela

    2015-07-01

    The generation of reactive species in titanium dioxide (TiO 2 ) nanoparticle photocatalysis was assessed in a laboratory scale setup, in which P25 Aeroxide TiO 2 suspensions were photoactivated by means of UV-A radiation. Photogenerated holes and hydroxyl radicals were monitored over time by observing their selective reaction with probe compounds, iodide and terephthalic acid, respectively. TiO 2 aggregate size and structure were characterized over the reaction time. Reactive species quenching was then described by a model, accounting for radiative phenomena, TiO 2 nanoparticle aggregation and kinetic reactions. The interaction between iodide and photogenerated holes was influenced by iodide adsorption on TiO 2 surface, described by a Langmuir-Hinshelwood mechanism, whose parameters were studied as a function of TiO 2 concentration and irradiation time. Iodide oxidation was effectively simulated by modelling the reaction volume as a completely stirred two-dimensional domain, in which irradiation phenomena were described by a two-flux model and the steady state for reactive species was assumed. The kinetic parameters for iodide adsorption and oxidation were estimated and successfully validated in a different experimental setup. The same model was adapted to describe the oxidation of terephthalic acid by hydroxyl radicals. The kinetic parameters for terephthalic acid oxidation were estimated and validated, while the issues in investigating the interaction mechanisms among the involved species have been discussed. The sensitivity of operating parameters on model response was assessed and the most relevant parameters were highlighted.

  7. Gas Injection And Fast Pressure-Rise Measurements For The Linac4 H− Source

    CERN Document Server

    Mahner, E; Lettry, J; Mattei, S; O'Neil, M; Neupert, H; Pasquino, C; Schmitzer, C

    2013-01-01

    In the era of the Large Hadron Collider, the CERN injector complex comprising the 34 years old Linac2 with its primary proton source, is presently upgraded with a new linear accelerator for H− (Linac4). The design, construction, and test of volume production and cesiated RF-driven H− ion sources is presently ongoing with the final goal of producing an H− beam with 80 mA beam current, 45 keV beam energy, 500 s pulse length, and a repetition rate of 2 Hz. In order to have quantitative information of the hydrogen gas density at the moment of plasma ignition the dynamic vacuum properties of the plasma generator were studied experimentally. We describe the experimental setup and present fast pressure-rise measurements for different parameters of the gas injection system, such as gas species (H2, He, N2, Ar), piezo valve voltage pulse length (200 - 500 s), and injection pressure (400 - 2800 mbar). The obtained data are compared with a conductance model of the plasma generator.

  8. Design, analysis and measurement of very fast kicker magnets at SLAC

    International Nuclear Information System (INIS)

    Weaver, J.N.; Bowden, G.B.; Bulos, F.

    1989-03-01

    Recent experience with SLC has shown that very fast, ferrite-loaded, transmission-line, beam-kicker magnets can cause significant and undesirable distortion of a 1.5-2.5 kA, 20-4- kV pulse as it travels through the magnet. In general, there is a net lengthening of the pulse, with increases in its rise and fall times, a decrease in amplitude, and an unsymmetrical rounding of the flattop. In this partially tutorial treatise, a number of practical design considerations are discussed in terms of equivalent circuits, magnet circuit dispersion and dissipation, undesired circuit shunting and coupling, high-voltage breakdown problems and high-order-mode losses that lead to beam tube heating. These effects are linked to the properties of the materials, the presence of radiation and realizable magnet topologies. Measurements and calculations of some of these characteristics for several magnet designs are reviewed. The results presented come from a truly eclectic effort. 8 refs., 1 fig

  9. Linear and Non-linear Numerical Sea-keeping Evaluation of a Fast Monohull Ferry Compared to Full Scale Measurements

    DEFF Research Database (Denmark)

    Wang, Zhaohui; Folsø, Rasmus; Bondini, Francesca

    1999-01-01

    The past years have seen a growing interest in fast ships for both cargo and passenger transportation. Different designs have been considered, but recently attention has been focused on fast monohull displacement ships. To gain more knowledge and experience on the behaviour of this kind of ships......, full-scale measurements have been performed on board a 128 m monohull fast ferry. This paper deals with the results from these full-scale measurements. The primary results considered are pitch motion, midship vertical bending moment and vertical acceleration at the bow. Previous comparisons between...... model experiments and numerical sea-keeping calculations indicate that conventional low speed strip theories yield reasonable results even at very high Froude members. To confirm this, the present paper presents the results from the performed full scale members. To confirm this, the present paper...

  10. Advancing Reactive Tracer Methods for Measurement of Thermal Evolution in Geothermal Reservoirs: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell A. Plummer; Carl D. Palmer; Earl D. Mattson; Laurence C. Hull; George D. Redden

    2011-07-01

    The injection of cold fluids into engineered geothermal system (EGS) and conventional geothermal reservoirs may be done to help extract heat from the subsurface or to maintain pressures within the reservoir (e.g., Rose et al., 2001). As these injected fluids move along fractures, they acquire heat from the rock matrix and remove it from the reservoir as they are extracted to the surface. A consequence of such injection is the migration of a cold-fluid front through the reservoir (Figure 1) that could eventually reach the production well and result in the lowering of the temperature of the produced fluids (thermal breakthrough). Efficient operation of an EGS as well as conventional geothermal systems involving cold-fluid injection requires accurate and timely information about thermal depletion of the reservoir in response to operation. In particular, accurate predictions of the time to thermal breakthrough and subsequent rate of thermal drawdown are necessary for reservoir management, design of fracture stimulation and well drilling programs, and forecasting of economic return. A potential method for estimating migration of a cold front between an injection well and a production well is through application of reactive tracer tests, using chemical whose rate of degradation is dependent on the reservoir temperature between the two wells (e.g., Robinson 1985). With repeated tests, the rate of migration of the thermal front can be determined, and the time to thermal breakthrough calculated. While the basic theory behind the concept of thermal tracers has been understood for some time, effective application of the method has yet to be demonstrated. This report describes results of a study that used several methods to investigate application of reactive tracers to monitoring the thermal evolution of a geothermal reservoir. These methods included (1) mathematical investigation of the sensitivity of known and hypothetical reactive tracers, (2) laboratory testing of novel

  11. Time resolved mass flow measurements for a fast gas delivery system

    International Nuclear Information System (INIS)

    Ruden, E.L.; Degnan, J.H.; Hussey, T.W.; Scott, M.C.; Graham, J.D.; Coffey, S.K.

    1992-01-01

    A technique is demonstrated whereby the delivered mass and flow rate vs. time of a short rise time gas delivery system may be accurately determined. The gas mass M which flows past a point in a gas delivery system by an arbitrary time t may be accurately measured if that point is sealed off within a time interval short compared to the mass flow time scale. If the ejected mass is allowed to equilibrate in a known volume after being cut off from its source, a conventional static pressure measurement before and after injection, and application of the ideal gas law suffices. Assuming reproducibility, a time history M(t) may be generated, allowing the flow rate vs. time dM(t)/dt to be determined. Mass flow measurements are presented for a fast delivery system in which the flow of argon through a 3.2 mm I.D., 0.76 mm thick copper tube is cut off by imploding (θ pinching) the tube using a single turn tungsten magnetic field coil. Pinch discharge parameters are 44 μf, 20 kV, 47 nH, 3.5 mΩ, 584 kA, and 8.63 ps current period. Optical measurements of the tube's internal area vs. time indicate that the tube is sealed 2 ps from the time the tube is still 90% open (7 μs from the start of pinch current). The pinch delay is varied from 500--1,500 ps from the valve trigger (0--1,000 ps from the start of gas flow). The mass injected into the test volume is ∼ 100 μg during this interval. The leak rate of the sealed tube results in a mass increase of only ∼ 0.1 μg by the time the pressure gauge stabilizes (6 s). Results are correlated with piezoelectric probe measurements of the gas flow and 2-D axisymmetric numerical simulations of the θ pinch process. Simulations of a θ pinch suitable for characterizing an annular supersonic nozzle typical of those used in gas puff z pinches are discussed

  12. Intercomparison of OH and OH reactivity measurements in a high isoprene and low NO environment during the Southern Oxidant and Aerosol Study (SOAS)

    Science.gov (United States)

    Sanchez, Dianne; Jeong, Daun; Seco, Roger; Wrangham, Ian; Park, Jeong-Hoo; Brune, William H.; Koss, Abigail; Gilman, Jessica; de Gouw, Joost; Misztal, Pawel; Goldstein, Allen; Baumann, Karsten; Wennberg, Paul O.; Keutsch, Frank N.; Guenther, Alex; Kim, Saewung

    2018-02-01

    We intercompare OH and OH reactivity datasets from two different techniques, chemical ionization mass spectrometry (CIMS) and laser-induced fluorescence (LIF) in a high isoprene and low NO environment in a southeastern US forest during the Southern Oxidant and Aerosol Study (SOAS). An LIF instrument measured OH and OH reactivity at the top of a tower, a CIMS instrument measured OH at the top of the tower, and a CIMS based comparative reactivity method (CRM-CIMS) instrument deployed at the base of the tower measured OH reactivity. Averaged diel variations of OH and OH reactivity from these datasets agree within analytical uncertainty and correlations of LIF versus CIMS for OH and OH reactivity have slopes of 0.65 and 0.97, respectively. However, there are systematic differences between the measurement datasets. The CRM-CIMS measurements of OH reactivity were ∼16% lower than those by the LIF technique in the late afternoon. We speculate that it is caused by losses in the sampling line down to the CRM-CIMS instrument. On the other hand, we could not come up with a reasonable explanation for the difference in the LIF and CIMS OH datasets for early morning and late afternoon when OH is below 1 × 106 molecules cm-3. Nonetheless, results of this intercomparison exercise strengthen previous publications from the field site on OH concentrations and atmospheric reactivity.

  13. RCRA corrective measures using a permeable reactive iron wall US Coast Guard Support Center, Elizabeth City, North Carolina

    International Nuclear Information System (INIS)

    Schmithors, W.L.; Vardy, J.A.

    1997-01-01

    A chromic acid release was discovered at a former electroplating shop at the U.S. Coast Guard Support Center in Elizabeth City, North Carolina. Initial investigative activities indicated that chromic acid had migrated into the subsurface soils and groundwater. In addition, trichloroethylene (TCE) was also discovered in groundwater during subsequent investigations of the hexavalent chromium (Cr VI) plume. Corrective measures were required under the Resource Conservation and Recovery Act (RCRA). The in-situ remediation method, proposed under RCRA Interim Measures to passively treat the groundwater contaminants, uses reactive zero-valent iron to reductively dechlorinate the chlorinated compounds and to mineralize the hexavalent chromium. A 47 meter by 0.6 meter subsurface permeable iron wall was installed downgradient of the source area to a depth of 7 meters using a direct trenching machine. The iron filings were placed in the ground as the soils were excavated from the subsurface. This is the first time that direct trenching was used to install reactive zero-valent iron filings. Over 250 metric tons of iron filings were used as the reactive material in the barrier wall. Installation of the iron filings took one full day. Extensive negotiations with regulatory agencies were required to use this technology under the current facility Hazardous Waste Management Permit. All waste soils generated during the excavation activities were contained and treated on site. Once contaminant concentrations were reduced the waste soils were used as fill material

  14. Revisiting the dispersion measure of fast radio bursts associated with gamma-ray burst afterglows

    International Nuclear Information System (INIS)

    Yu, Yun-Wei

    2014-01-01

    Some fast radio bursts (FRBs) are expected to be associated with the afterglow emission of gamma-ray bursts (GRBs), while a short-lived, supermassive neutron star (NS) forms during the GRBs. I investigate the possible contributions to the dispersion measure (DM) of the FRBs from the GRB ejecta and the wind blown from the precollapsing NS. On the one hand, sometimes an internal X-ray plateau afterglow could be produced by the NS wind, which indicates that a great number of electron-positron pairs are carried by the wind. If the pair-generation radius satisfies a somewhat rigorous condition, the relativistic and dense wind would contribute a high DM to the associated FRB, which can be comparable to and even exceed the DM contributed by the intergalactic medium. On the other hand, if the wind only carries a Goldreich-Julian particle flux, its DM contribution would become negligible; meanwhile, the internal plateau afterglow would not appear. Alternatively, the FRB should be associated with a GRB afterglow produced by the GRB external shock, i.e., an energy-injection-caused shallow-decay afterglow or a normal single-power-law afterglow if the impulsive energy release of the GRB is high enough. In the latter case, the DM contributed by the high-mass GRB ejecta could be substantially important, in particular, for an environment of main-sequence stellar wind. In summary, a careful assessment on the various DM contributors could be required for the cosmological application of the expected FRB-GRB association. The future DM measurements of GRB-associated FRBs could provide a constraint on the physics of NS winds.

  15. Sensitization to the psychosis-inducing effects of cocaine compared with measures of cocaine craving and cue reactivity.

    Science.gov (United States)

    Reid, Malcolm S; Ciplet, Debra; O'Leary, Siobhan; Branchey, Marc; Buydens-Branchey, Laure; Angrist, Burt

    2004-01-01

    A previous study has suggested that sensitization to the psychosis-inducing effects of cocaine may be a marker of vulnerability to relapse in cocaine addiction. In this report, cocaine-dependent subjects participating in a study on naturally occurring and cue-induced cocaine craving were interviewed about prior experience of cocaine-induced psychosis and the degree to which this effect had become more frequent or severe or had occurred at lower cumulative doses. Sensitization to cocaine-induced psychosis was negatively correlated with baseline measures of drug dependence severity and indices of cocaine craving over the preceding 24 hours but not with measures of cocaine cue reactivity.

  16. Measurement of reactivity loss with burnup in PWR, BWR and MOX fuel in the CERES collaborative programme

    Energy Technology Data Exchange (ETDEWEB)

    Gulliford, N.T.; Hanlon, D. [AEA Technology, Winfrith (United Kingdom)

    1996-09-01

    Measurements have been made on samples of spent PWR, BWR and MOX fuel in the DIMPLE reactor to validate codes and data used to predict reactivity loss with burnup. This work has been carried out as part of an International Collaborative Programme known as CERES and includes the participation of the UK, France and the USA. Measurements have also been made on thirteen of the major fission product absorbers to validate neutron cross-section data for these isotopes. Comparisons with calculations based on AEA Technology`s WIMS Reactor Physics Code using the JEF2.2 data library show excellent agreement for a wide range of irradiated fuel samples. (author)

  17. Reactivity and neutron flux measurements in IPEN/MB-01 reactor with B4C burnable poison

    International Nuclear Information System (INIS)

    Fer, Nelson Custodio; Moreira, Joao Manoel Losada

    2000-01-01

    Burnable poison rods, made of B 4 C- Al 2 O 3 pellets with 5.01 mg/cm 3 10 B concentration, have been manufactured for a set of experiments in the IPEN/MB-01 zero-power reactor. Several core parameters which are affected by the burnable poisons rods have been measured. The principal results, for the situation in which the burnable poison rods are located near the absorber rods of a control rod, are they cause a 29% rod worth shadowing, a reduction of 39% in the local void coefficient of reactivity, a reduction of 4.8% in the isothermal temperature coefficient of reactivity, and a reduction of 9% in the thermal neutron flux in the region where the burnable poison rods are located. These experimental results will be used for the validation of burnable poison calculation methods in the CTMSP. (author)

  18. Development of ionization technique for measurement of fast neutron induced fission products yields of {sup 237}Np

    Energy Technology Data Exchange (ETDEWEB)

    Goverdovski, A.A.; Khryachkov, V.A.; Ketlerov, V.V.; Mitrofanov, V.F.; Ostapenko, Yu.B.; Semenova, N.N.; Fomichev, A.N.; Rodina, L.F. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-03-01

    Twin gridded ionization chamber and corresponding software was designed for measurements of masses, kinetic energies and nuclear charges of fission fragments from fast neutron induced fission of {sup 237}Np. The ionization detector design, electronics, data acquisition and processing system and the test results are presented in this paper. (J.P.N.)

  19. Temperature-dependent attenuation of ex-vessel flux measurements at the Hanford Fast Flux Test Facility

    International Nuclear Information System (INIS)

    McLane, F.E.; Wood, M.R.; Rathbun, J.L.

    1982-01-01

    Indicated nuclear power, developed by measuring leakage neutrons, has been found to be temperature dependent at the Hanford Fast Flux Test Facility (FFTF). The magnitude, sense and speed of response of the effect suggest that hot sodium above th core and shield is a significant cause. Future designs which may minimize this effect are discussed

  20. Measurement system of gamma, X, thermal and/or fast neutron flux

    International Nuclear Information System (INIS)

    Siffert, P.; Regal, R.; Koebel, J.M.; Teissier, C.

    1987-01-01

    The system includes detection means of gamma or/and X radiation, detection means of gamma and/or X radiation from thermal neutrons, detection means of gamma and/or X radiation from thermal and/or fast neutrons. It includes also processing devices of the signals given by the detection means able to get a linear combination of the detected signals. These processing devices give a signal selectively representative of photon, thermal or fast neutron rate [fr

  1. Latest on Mobile Methane Measurements with Fast Open-Path Technology: Experiences, Opportunities & Perspectives

    Science.gov (United States)

    Burba, George; Anderson, Tyler; Ediger, Kevin; von Fischer, Joseph; Gioli, Beniamino; Ham, Jay; Hupp, Jason; Kohnert, Katrin; Larmanou, Eric; Levy, Peter; Polidori, Andrea; Pikelnaya, Olga; Price, Eric; Sachs, Torsten; Serafimovich, Andrei; Zondlo, Mark; Zulueta, Rommel

    2016-04-01

    Methane plays a critical role in the radiation balance, chemistry of the atmosphere, and air quality. The major sources of methane include agricultural and natural production, landfill emissions, oil and gas development sites, and natural gas distribution networks in rural and urban environments. The majority of agricultural and natural methane production occurs in areas with little infrastructure or easily available grid power (e.g., rice fields, arctic and boreal wetlands, tropical mangroves, etc.) Past approaches for direct measurements of methane fluxes relied on fast closed-path analyzers, which typically require powerful pumps and grid power. Power and labor demands may be among the key reasons why such methane fluxes were often measured at locations with good infrastructure and grid power, and not necessarily with high methane production. Landfill methane emissions were traditionally assessed via point-in-time measurements taken at monthly or longer time intervals using techniques such as the trace plume method, the mass balance method, etc. These are subject to large uncertainties because of the snapshot nature of the measurements, while the changes in emission rates are continuous due to ongoing landfill development, changes in management practices, and the barometric pumping phenomenon. Installing a continuously operating flux station in the middle of an active landfill requires a low-power approach with no cables stretching across the landfill. The majority of oil and gas and urban methane emission happens via variable-rate point sources or diffused spots in topographically challenging terrains, such as street tunnels, elevated locations at water treatment plants, vents, etc. Locating and measuring methane emissions from such sources is challenging when using traditional micrometeorological techniques, and requires development of novel approaches. In 2010, a new lightweight high-speed high-resolution open-path technology was developed with the goal of

  2. A new fast neutron collar for safeguards inspection measurements of fresh low enriched uranium fuel assemblies containing burnable poison rods

    International Nuclear Information System (INIS)

    Evans, Louise G.; Swinhoe, Martyn T.; Menlove, Howard O.; Schwalbach, Peter; Baere, Paul De; Browne, Michael C.

    2013-01-01

    Safeguards inspection measurements must be performed in a timely manner in order to detect the diversion of significant quantities of nuclear material. A shorter measurement time can increase the number of items that a nuclear safeguards inspector can reliably measure during a period of access to a nuclear facility. In turn, this improves the reliability of the acquired statistical sample, which is used to inform decisions regarding compliance. Safeguards inspection measurements should also maintain independence from facility operator declarations. Existing neutron collars employ thermal neutron interrogation for safeguards inspection measurements of fresh fuel assemblies. A new fast neutron collar has been developed for safeguards inspection measurements of fresh low-enriched uranium (LEU) fuel assemblies containing gadolinia (Gd 2 O 3 ) burnable poison rods. The Euratom Fast Collar (EFC) was designed with high neutron detection efficiency to make a fast (Cd) mode measurement viable whilst meeting the high counting precision and short assay time requirements of the Euratom safeguards inspectorate. A fast mode measurement reduces the instrument sensitivity to burnable poison rod content and therefore reduces the applied poison correction, consequently reducing the dependence on the operator declaration of the poison content within an assembly. The EFC non-destructive assay (NDA) of typical modern European pressurized water reactor (PWR) fresh fuel assembly designs have been simulated using Monte Carlo N-particle extended transport code (MCNPX) simulations. Simulations predict that the EFC can achieve 2% relative statistical uncertainty on the doubles neutron counting rate for a fast mode measurement in an assay time of 600 s (10 min) with the available 241 AmLi (α,n) interrogation source strength of 5.7×10 4 s −1 . Furthermore, the calibration range of the new collar has been extended to verify 235 U content in variable PWR fuel designs in the presence of up to

  3. Development of a very fast spectral response measurement system for analysis of hydrogenated amorphous silicon solar cells and modules

    International Nuclear Information System (INIS)

    Rodríguez, J.A.; Fortes, M.; Alberte, C.; Vetter, M.; Andreu, J.

    2013-01-01

    Highlights: ► Spectral response equipment for measuring a-Si:H solar cells in a few seconds. ► Equipment based on 16 LEDs with simultaneous illumination of the solar cell. ► The current generated by each LED is analyzed by a Fast Fourier Transform. ► Cheap equipment without lock-in technology for the current measurement. ► Measurement error vs. conventional measurement less than 1% in J sc . - Abstract: An important requirement for a very fast spectral response measurement system is the simultaneous illumination of the solar cell at multiple well defined wavelengths. Nowadays this can be done by means of light emitting diodes (LEDs) available for a multitude of wavelengths. For the purpose to measure the spectral response (SR) of amorphous silicon solar cells a detailed characterization of LEDs emitting in the wavelength range from 300 nm to 800 nm was performed. In the here developed equipment the LED illumination is modulated in the frequency range from 100 Hz to 200 Hz and the current generated by each LED is analyzed by a Fast Fourier Transform (FFT) to determine the current component corresponding to each wavelength. The equipment provides a signal to noise ratio of 2–4 orders of magnitude for individual wavelengths resulting in a precise measurement of the SR over the whole wavelength range. The difference of the short circuit current determined from the SR is less than 1% in comparison to a conventional system with monochromator.

  4. Towards fast measurement of the electron temperature in the SOL of ASDEX upgrade using swept Langmuir probes

    International Nuclear Information System (INIS)

    Mueller, H.W.; Rohde, V.; Adamek, J.; Horacek, J.; Schrittwieser, R.; Ionita, C.; Mehlmann, F.

    2010-01-01

    On ASDEX Upgrade first experiments were made using single probes with a voltage sweep frequency up to 100kHz. Possibilities and limitations using fast swept probes with a standard diagnostic and analysis tools are discussed. A good agreement between the data derived from fast swept single probe characteristics and floating as well as saturation current measurements was found. In a stationary (non ELMing) plasma the data of the fast swept probe are compared to standard slow swept probes (kHz range) showing an improvement of the measurement by faster sweeping. While ELM filaments already could be resolved the access of electron temperature fluctuations in small scale turbulence still has to be improved. Further comparisons are done in ELMy H-mode with combined ball-pen probe/floating potential measurements which can deliver electron temperatures with 25μs time resolution at reduced spatial resolution compared to pin probes. During ELMs the electron temperatures derived from the ball-pen probe and fast swept single probes agreed (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  5. Water-soluble vitamin homeostasis in fasting northern elephant seals (Mirounga angustirostris) measured by metabolomics analysis and standard methods.

    Science.gov (United States)

    Boaz, Segal M; Champagne, Cory D; Fowler, Melinda A; Houser, Dorian H; Crocker, Daniel E

    2012-02-01

    Despite the importance of water-soluble vitamins to metabolism, there is limited knowledge of their serum availability in fasting wildlife. We evaluated changes in water-soluble vitamins in northern elephant seals, a species with an exceptional ability to withstand nutrient deprivation. We used a metabolomics approach to measure vitamins and associated metabolites under extended natural fasts for up to 7 weeks in free-ranging lactating or developing seals. Water-soluble vitamins were not detected with this metabolomics platform, but could be measured with standard assays. Concentrations of measured vitamins varied independently, but all were maintained at detectable levels over extended fasts, suggesting that defense of vitamin levels is a component of fasting adaptation in the seals. Metabolomics was not ideal for generating complete vitamin profiles in this species, but gave novel insights into vitamin metabolism by detecting key related metabolites. For example, niacin level reductions in lactating females were associated with significant reductions in precursors suggesting downregulation of the niacin synthetic pathway. The ability to detect individual vitamins using metabolomics may be impacted by the large number of novel compounds detected. Modifications to the analysis platforms and compound detection algorithms used in this study may be required for improving water-soluble vitamin detection in this and other novel wildlife systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Experimental subcritical reactivity determinations employing APSD measurements with pulse mode detectors in the IPEN/MB-01 reactor

    International Nuclear Information System (INIS)

    Santos, Adimir dos; Lee, Seung Min; Diniz, Ricardo; Jerez, Rogerio

    2011-01-01

    This work aims to determine experimentally the subcritical reactivity levels of several configurations of the IPEN/MB-01 reactor in an approach based on the subcritical kinetic model developed by Gandini and Salvatores. The procedure employs the measurements of the APSD (Auto Power Spectral Density) using pulse mode detectors. The proposed approach is based only on measured quantities such as counting rates and the parameters arising from the least square approach of the APSD. Other difficult quantity such as detector efficiencies is not needed in the method. Several measurements of APSD were performed in varying degrees of sub-criticality (up to around -7000 pcm). The APSD data were least-square fitted to get the prompt decay mode (α). Beside the startup source, an external neutron sources of Am-Be was installed near the core in order to improve neutron count statistics. The final experimental results are of very good quality. The experiment shows clearly that the classical one point kinetic theory cannot describe the measured reactivity. MCNP K eff results were compared to the corresponding experimental results. The agreement was fairly good. (author)

  7. Design of optimal fast scanning trajectory for the mechanical scanner of measurement instruments.

    Science.gov (United States)

    Ju, Bing-Feng; Bai, Xiaolong; Chen, Jian; Ge, Yaozheng

    2014-01-01

    This paper focuses on the design of the optimal scanning mode for the family of scanning probe microscopes. Based on different values of the maximum acceleration (deceleration) rate and maximum speed of X- and Y- axes of the mechanical scanner encountered in practice due to different mechanical design and loads, the design procedure of the optimal fast scanning mode is presented, which is found to be sensitive to the specific parameters of the scanning motion. By utilizing the simultaneous motion of the two axes, the fast raster scanning mode proposed can improve the scanning efficiency by 29% when comparing with the conventional raster (CR) scanning mode, if the scanning speeds of both axes are identical. In addition, the optimal fast mode provided by us has no effects on the image accuracy such as image degradation, image distortion when the efficiency is evaluated. No further difficulties are introduced to the control of the mechanical scanner and the data acquisition process. This optimal scanning mode is useful when the response time of the probe is very fast (such as ultrasonic probe in scanning acoustic microscope (SAM)), and the main limitations are due to the mechanical scanner. By applying different loads for both axes, the experiments with different scanning areas and scanning modes are conducted in a self-developed SAM. Experimental results coincide with the theoretical analysis and confirm the validation of our proposed optimal fast scanning mode and its superiority over the CR scanning mode. © 2013 Wiley Periodicals, Inc.

  8. Identifying fast-food restaurants using a central register as a measure of the food environment.

    Science.gov (United States)

    Toft, Ulla; Erbs-Maibing, Peter; Glümer, Charlotte

    2011-12-01

    To validate the identification and location of fast-food restaurants according to a government list of inspected food stores and restaurants. Fast-food restaurants in the Capital Region of Denmark were identified using a government list of inspected food stores and restaurants (the Smiley register, spring 2010). Ground-truthing was used as the validation method and was performed in May and June 2010 in 125 randomly selected 250×250 m grid cells. A total of 186 fast-food restaurants was identified by ground-truthing and 99% of these were registered in the same grid cell by the Smiley register. However, only 152 restaurants of these were categorised as fast-food restaurants by both methods. The sensitivity was 82% and the positive predictive value was 92%. The mean±standard deviation position accuracy was 15±24 m. Using a government list of inspected restaurants was found to be a valid and useful alternative to expensive and time-consuming field observation and provided a relatively accurate tool for identifying and locating fast-food restaurants in communities.

  9. Development of an automated sampling-analysis system for simultaneous measurement of reactive oxygen species (ROS) in gas and particle phases: GAC-ROS

    Science.gov (United States)

    Huang, Wei; Zhang, Yuanxun; Zhang, Yang; Zeng, Limin; Dong, Huabin; Huo, Peng; Fang, Dongqing; Schauer, James J.

    2016-06-01

    A novel online system, GAC-ROS, for simultaneous measurement of reactive oxygen species (ROS) in both gas and particle phases was developed based on 2‧,7‧-dichlorofluorescin (DCFH) assay to provide fast sampling and analysis of atmospheric ROS. The GAC-ROS, composed of a Gas and Aerosol Collector (GAC), a series of reaction and transportation systems, and a fluorescence detector, was tested for instrumental performance in laboratory. Results showed good performance with a favorable R2 value for the calibration curve (above 0.998), high penetration efficiencies of ROS (above 99.5%), and low detection limits (gas-phase ROS: 0.16 nmol H2O2 m-3; particle-phase ROS: 0.12 nmol H2O2 m-3). Laboratorial comparison between online and offline methods for particle-bound ROS showed significant loss of ROS due to the relatively long time off-line treatment. Field observations in Beijing found that concentrations of ROS in winter time were significantly higher than those observed in spring. Only a few weak positive correlations were found between ROS and some air pollutants, which reflects the complexities of ROS generation and transformation in atmosphere. This study was the first to simultaneously obtain concentrations of gas and particle-phase ROS using an online method. Consequently, it provides a powerful tool to characterize the oxidizing capacity of the atmosphere and the sources of the oxidizing capacity.

  10. Constraints on Vesta's elemental composition: Fast neutron measurements by Dawn's gamma ray and neutron detector

    Science.gov (United States)

    Lawrence, David J; Peplowski, Patrick N; Prettyman, Thomas H; Feldman, William C; Bazell, David; Mittlefehldt, David W; Reedy, Robert C; Yamashita, Naoyuki

    2013-01-01

    Surface composition information from Vesta is reported using fast neutron data collected by the gamma ray and neutron detector on the Dawn spacecraft. After correcting for variations due to hydrogen, fast neutrons show a compositional dynamic range and spatial variability that is consistent with variations in average atomic mass from howardite, eucrite, and diogenite (HED) meteorites. These data provide additional compositional evidence that Vesta is the parent body to HED meteorites. A subset of fast neutron data having lower statistical precision show spatial variations that are consistent with a 400 ppm variability in hydrogen concentrations across Vesta and supports the idea that Vesta's hydrogen is due to long-term delivery of carbonaceous chondrite material. PMID:26074718

  11. Utilization of synchronization measures in the fast gas-dynamic experiment

    Science.gov (United States)

    Gilev, V. M.; Vnuchkov, D. A.; Nalivajchenko, D. G.; Shpak, S. I.

    2017-10-01

    This paper presents the system of synchronization for automated fast gas-dynamic experiments, including the experiments with combustion. The system permits using both super- and hypersonic processes in the pulse mode, the duration ranging from several milliseconds to seconds. Under consideration are individual elements of the system, technique of the fast experiment performance; the developed software is described. The description of the weight test of the model of a small-size high-speed aircraft realized with the present system is presented as an example.

  12. Subsurface deformation measurements during a fast shallow landslide triggered by rainfall

    Science.gov (United States)

    Askarinejad, Amin; Springman, Sarah M.; Akca, Devrim; Bleiker, Ernst; Gruen, Armin

    2010-05-01

    A forested area in Ruedlingen, northern Switzerland, was selected to investigate the geotechnical and hydrological response of a steep slope prior to a rainfall induced failure. Artificial rainfall was applied according to a pre-planned schedule and parameters such as pore water pressure, volumetric water content, horizontal soil pressure, temperature, piezometric water level and subsurface deformations were monitored. The latter were determined from four deformation probes that were developed in the Institute for Geotechnical Engineering, ETHZ. Strain gauges have been attached at a regular spacing along a long, slender, flexible plate to enable measurements of bending strain to be made at different points along it. The strain gauges were connected as 'half bridges' to minimize the temperature effects. A biaxial inclinometer was also installed on the top of the plate, 20 cm above the soil surface, to measure the tilt above ground level, providing more boundary conditions to determine the deformed shape of the probe. The probe is installed vertically inside the soil, while the lowest part is grouted into the stiffer layer under the topsoil, and is assumed to be stable and without any rotation. Bending strains and the inclination at the top of the probe are sampled at a frequency of 100 Hz. These are input into an algorithm to determine a polynomial relationship of deformations and rotations with depth, so that the initiation of slow movements and propagation of failure during fast soil mass movements can be examined. A 4-camera arrangement was used for the image acquisition to monitor surface movements using photogrammetric analyses. Approximately 250 white ping-pong balls were attached to the ground and used as target points. Using a network simulation tool that was developed in-house, an a priori point positioning accuracy of the ping-pong balls was estimated to be ± 10.3 mm along the horizontal direction and ± 3.5 mm in the vertical direction. The cameras

  13. Effects of several types of biomass fuels on the yield, nanostructure and reactivity of soot from fast pyrolysis at high temperatures

    DEFF Research Database (Denmark)

    Trubetskaya, Anna; Jensen, Peter Arendt; Jensen, Anker Degn

    2016-01-01

    This study presents the effect of biomass origin on the yield, nanostructure and reactivity of soot. Soot was produced from wood and herbaceous biomass pyrolysis at high heating rates and at temperatures of 1250 and 1400 °C in a drop tube furnace. The structure of solid residues was characterized...

  14. Study of Material Moisture Measurement Method and Instrument by the Combination of Fast Neutron Absorption and γ Absorption

    International Nuclear Information System (INIS)

    Hou Chaoqin; Gong Yalin; Zhang Wei; Shang Qingmin; Li Yanfeng; Gou Qiangyuan; Yin Deyou

    2010-01-01

    To solve the problem of on-line sinter moisture measurement in the iron making plant, we developed material moisture measurement method and instrument by the combination of fast neutron absorption and y-absorption. It overcomes the present existed problems of other moisture meters for the sinter. Compare with microwave moisture meter, the measurement dose not affected by conductance and magnetism of material; to infrared moisture meter, the measurement result dose not influenced by colour and light-reflect performance of material surface, dose not influenced by changes of material kind; to slow neutron scatter moisture meter, the measurement dose not affected by density of material and thickness of hopper wall; to the moisture measurement meter which combined by slow neutron penetrate through and y-absorption, there are definite math model and good linear relation between the measurement values, and the measurement dose not affected by material thickness, changes of material form and component. (authors)

  15. Global Modelling of the total OH reactivity: validation against measurements and atmospheric implications of the 'missing' sink

    Science.gov (United States)

    Ferracci, Valerio; Archibald, Alexander T.; Pyle, John A.

    2017-04-01

    The removal of most trace gases emitted into the atmosphere is primarily initiated by reaction with the hydroxyl radical, OH. A number of field campaigns over the last two decades have observed the presence of a "missing" sink of the OH radical in a variety of regions across the planet, from urban areas to remote forests: comparison of the direct measurements of the OH loss rate, also known as total OH reactivity, with the sum of individual known OH sinks (obtained via the simultaneous detection of species such as volatile organic compounds and nitrogen oxides) indicated that, in some cases, up to 80% of the total OH loss rate was unaccounted for. The implications of this finding are significant, as a potentially major OH sink operating in the atmosphere is not currently accounted for in atmospheric models: the presence of an additional OH sink might, for instance, lead to an increase in the atmospheric lifetime of a number of trace species, including high-impact greenhouse gases such as methane. The only modelling of the total OH reactivity is currently performed on a regional scale; a thorough assessment of the impact of the missing sink on the chemistry and climate of the planet by global modelling is therefore highly desirable. In this work a chemistry-climate model (the Met Office's Unified Model with the United Kingdom Chemistry and Aerosols scheme, UM-UKCA) was used to calculate the total OH reactivity at the planetary boundary layer. The model output was validated against available field measurements to verify that the known OH sinks observed in the field were reproduced correctly by the model: a good agreement was found between the data from more than 30 field campaigns and the model output. Following this, the effects of introducing novel OH sinks in the chemistry scheme were investigated. The first step was the introduction in the model of the newly characterised reactions of peroxy radicals (RO2) with OH, the kinetics and products of which have only

  16. Diagnosis of bile acid diarrhoea by fasting and postprandial measurements of fibroblast growth factor 19

    DEFF Research Database (Denmark)

    Borup, Christian; Syversen, Charlotte; Bouchelouche, Pierre

    2015-01-01

    BACKGROUND: A deficiency in the ileal hormone fibroblast growth factor 19 (FGF19) has been described in patients with bile acid diarrhoea (BAD), but fasting FGF19 levels have insufficient diagnostic power. We assess whether single postprandial sampling of FGF19 has greater discriminative value than...

  17. Mensuração da qualidade de serviço em empresas de fast food Measuring service quality in fast food companies

    Directory of Open Access Journals (Sweden)

    Melise Dantas Machado

    2006-05-01

    Full Text Available As mais importantes teorias sobre serviço afirmam que o consumidor estará satisfeito se perceber no serviço prestado um desempenho melhor ou igual às suas expectativas. A comparação entre a percepção de desempenho e a expectativa do consumidor em relação a cada item de serviço fornecerá o Gap (lacuna de satisfação. Quanto maior esse Gap, mais insatisfeito estará o consumidor com relação ao serviço prestado. Considerando este constructo, o objetivo deste artigo é verificar as determinantes da qualidade de serviço em empresas fast food. Para tanto, um instrumento de mensuração da qualidade em serviço - SERVQUAL - foi adaptado ao setor em questão e um survey foi realizado com 120 consumidores. Pelos resultados obtidos, pode-se verificar que a empresa pesquisada satisfaz os consumidores no que diz respeito a duas dimensões da qualidade e tem uma avaliação negativa para outras quatro, o que indica que ações de melhoria devem ser tomadas para satisfazer efetivamente os consumidores.The most important theories about service state that the consumer is satisfied if he considers the service meets or exceeds his expectations. A comparison of the consumer's perception of the performance and his expectations regarding each aspect of the service indicates the satisfaction gap. The greater the gap the higher the consumer's dissatisfaction with the service. Based on this assumption, this paper aims to identify the factors that determine the quality of services rendered by fast food companies. To this end, a quality-measuring instrument - SERVQUAL - was adapted to this business sector and a survey was carried out involving 120 customers of a specific fast food company. The results indicated that the company satisfied its customers in two quality dimensions but was negatively evaluated in four others, indicating the need for actions aimed at improving its service in order to effectively satisfy its customers.

  18. Impact of Ramadan Intermittent Fasting on Oxidative Stress Measured by Urinary 15-F2t-Isoprostane

    Science.gov (United States)

    Faris, Mo'ez Al-Islam Ezzat; Hussein, Rand Nidal; Al-Kurd, Ref'at Ahmad; Al-Fararjeh, Mohammed Ahmed; Bustanji, Yasser Khalil; Mohammad, Mohammad Khalil

    2012-01-01

    Fasting and caloric restriction have been associated with reduced incidence of chronic diseases and cancers. These effects have been attributed to reduced oxidative stress. Since Ramadan intermittent fasting (RIF) has been associated with reduced caloric intake, it was hypothesized that RIF would alleviate oxidative stress in healthy volunteers. The study was designed to elucidate the impact of RIF on oxidative stress measured by 15-F2t-Isoprostane (15FIP). Fifty healthy subjects (23 men and 27 women) who intended to fast Ramadan were recruited. Urine and serum sampling and anthropometric and dietary assessments were conducted one week before Ramadan (T0), at the end of the third week of Ramadan (T1), and one month after Ramadan (T2). Biochemical measurements included urinary 15FIP, creatinine, and hematological indices. Results revealed that the urinary level of 15FIP measured at T0 was normal, while they showed a significantly (P < 0.05) higher level when measured at T1 concomitant with a significant (P < 0.05) increase in the body weight and total body fat percent. In conclusion, results suggest that increased body weight is associated with increased lipid peroxidation and oxidative stress, and the impact of RIF on oxidative stress is mediated by the changes in body weight at the end of the month. PMID:23150812

  19. Development of a three dimensional homogeneous calculation model for the BFS-62 critical experiment. Preparation of adjusted equivalent measured values for sodium void reactivity values. Final report

    International Nuclear Information System (INIS)

    Manturov, G.; Semenov, M.; Seregin, A.; Lykova, L.

    2004-01-01

    The BFS-62 critical experiments are currently used as 'benchmark' for verification of IPPE codes and nuclear data, which have been used in the study of loading a significant amount of Pu in fast reactors. The BFS-62 experiments have been performed at BFS-2 critical facility of IPPE (Obninsk). The experimental program has been arranged in such a way that the effect of replacement of uranium dioxied blanket by the steel reflector as well as the effect of replacing UOX by MOX on the main characteristics of the reactor model was studied. Wide experimental program, including measurements of the criticality-keff, spectral indices, radial and axial fission rate distributions, control rod mock-up worth, sodium void reactivity effect SVRE and some other important nuclear physics parameters, was fulfilled in the core. Series of 4 BFS-62 critical assemblies have been designed for studying the changes in BN-600 reactor physics from existing state to hybrid core. All the assemblies are modeling the reactor state prior to refueling, i.e. with all control rod mock-ups withdrawn from the core. The following items are chosen for the analysis in this report: Description of the critical assembly BFS-62-3A as the 3rd assembly in a series of 4 BFS critical assemblies studying BN-600 reactor with MOX-UOX hybrid zone and steel reflector; Development of a 3D homogeneous calculation model for the BFS-62-3A critical experiment as the mock-up of BN-600 reactor with hybrid zone and steel reflector; Evaluation of measured nuclear physics parameters keff and SVRE (sodium void reactivity effect); Preparation of adjusted equivalent measured values for keff and SVRE. Main series of calculations are performed using 3D HEX-Z diffusion code TRIGEX in 26 groups, with the ABBN-93 cross-section set. In addition, precise calculations are made, in 299 groups and Ps-approximation in scattering, by Monte-Carlo code MMKKENO and discrete ordinate code TWODANT. All calculations are based on the common system

  20. 3D shape and eccentricity measurements of fast rotating rough objects by two mutually tilted interference fringe systems

    Science.gov (United States)

    Czarske, J. W.; Kuschmierz, R.; Günther, P.

    2013-06-01

    Precise measurements of distance, eccentricity and 3D-shape of fast moving objects such as turning parts of lathes, gear shafts, magnetic bearings, camshafts, crankshafts and rotors of vacuum pumps are on the one hand important tasks. On the other hand they are big challenges, since contactless precise measurement techniques are required. Optical techniques are well suitable for distance measurements of non-moving surfaces. However, measurements of laterally fast moving surfaces are still challenging. For such tasks the laser Doppler distance sensor technique was invented by the TU Dresden some years ago. This technique has been realized by two mutually tilted interference fringe systems, where the distance is coded in the phase difference between the generated interference signals. However, due to the speckle effect different random envelopes and phase jumps of the interference signals occur. They disturb the phase difference estimation between the interference signals. In this paper, we will report on a scientific breakthrough on the measurement uncertainty budget which has been achieved recently. Via matching of the illumination and receiving optics the measurement uncertainty of the displacement and distance can be reduced by about one magnitude. For displacement measurements of a recurring rough surface a standard deviation of 110 nm were attained at lateral velocities of 5 m / s. Due to the additionally measured lateral velocity and the rotational speed, the two-dimensional shape of rotating objects is calculated. The three-dimensional shape can be conducted by employment of a line camera. Since the measurement uncertainty of the displacement, vibration, distance, eccentricity, and shape is nearly independent of the lateral surface velocity, this technique is predestined for fast-rotating objects. Especially it can be advantageously used for the quality control of workpieces inside of a lathe towards the reduction of process tolerances, installation times and

  1. Measurement and modelling of reactive transport in geological barriers for nuclear waste containment.

    Science.gov (United States)

    Xiong, Qingrong; Joseph, Claudia; Schmeide, Katja; Jivkov, Andrey P

    2015-11-11

    Compacted clays are considered as excellent candidates for barriers to radionuclide transport in future repositories for nuclear waste due to their very low hydraulic permeability. Diffusion is the dominant transport mechanism, controlled by a nano-scale pore system. Assessment of the clays' long-term containment function requires adequate modelling of such pore systems and their evolution. Existing characterisation techniques do not provide complete pore space information for effective modelling, such as pore and throat size distributions and connectivity. Special network models for reactive transport are proposed here using the complimentary character of the pore space and the solid phase. This balances the insufficient characterisation information and provides the means for future mechanical-physical-chemical coupling. The anisotropy and heterogeneity of clays is represented using different length parameters and percentage of pores in different directions. Resulting networks are described as mathematical graphs with efficient discrete calculus formulation of transport. Opalinus Clay (OPA) is chosen as an example. Experimental data for the tritiated water (HTO) and U(vi) diffusion through OPA are presented. Calculated diffusion coefficients of HTO and uranium species are within the ranges of the experimentally determined data in different clay directions. This verifies the proposed pore network model and validates that uranium complexes are diffusing as neutral species in OPA. In the case of U(vi) diffusion the method is extended to account for sorption and convection. Rather than changing pore radii by coarse grained mathematical formula, physical sorption is simulated in each pore, which is more accurate and realistic.

  2. A fast wire scanner, used to measure the transverse density distribution of beams circulating in an accelerator or storage ring.

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    Fast wire scanners are used to measure the transverse density distribution of beams circulating in an accelerator or storage ring. In order to minimize blow-up of the beam through multiple Coulomb scattering, the wires are very thin (in the version shown here it is actually a twisted strand of carbon fibres with a total diameter of about 25 microns) and are swept through the beam at high speed (a linear motor, not mounted here, accelerates the wires to up to 20 m/s). One measures either the secondary emission current from the wire, or the signal from a scintillator/photomultiplier combination downstream from the wire scanner receiving the shower from nuclear reactions of beam particles with the wire nuclei. There are four such fast wire scanners in the 26 GeV PS and eight in the 1.4 GeV Booster.

  3. Fast time resolution measurements of high concentrations of iodine above a Laminaria Digitata seaweed bed

    Science.gov (United States)

    Ball, Stephen; Adams, Thomas; Leblanc, Catherine; Potin, Philippe

    2013-04-01

    We report observations of extremely large concentrations of molecular iodine (I2) measured in situ above a seaweed bed composed of laminaria digitata (90%) and laminaria hyperborea (10%) growing in its natural habitat. Measurements were made off the coast of Roscoff in Brittany, France, during day-time low tides on several days in September and November 2012 with the greatest tidal amplitudes. Iodine was quantified using a portable, battery-powered broadband cavity enhanced absorption spectrometer (BBCEAS) deployed from the in-shore research vessel "Aurelia" operated by the Station Biologique de Roscoff. For the 5 second integration times used here, the BBCEAS instrument has a detection limit for iodine of 12 pptv (parts per trillion by volume). The boat was anchored above the seaweed bed before it was exposed to air by the ebbing tide; the boat was grounded on the seaweed bed around the tidal minimum, and then refloated as the incoming tide covered the seaweed. I2 concentrations were strongly anti-correlated with water depth. Initially little I2 was seen above background levels whilst the blades of the seaweed plants were floating on the water surface. However several hundred pptv of I2 was observed within a few minutes of the plants' stipes breaking the surface and first blades coming to rest on rocks out of the water. Iodine concentrations increased further as the tide ebbed, typically peaking around 1500 pptv around the tidal minimum (by which time the seaweed had been exposed for 45 minutes). I2 concentrations decreased rapidly back to background levels as the returning tide submerged the seaweeds. The concentration profiles showed a lot of high frequency structure, with I2 concentrations commonly varying by a factor 2 (or more) within 60 seconds. Additionally the profiles of I2 emitted from the seaweeds immediately below the instrument's inlet typically sat on a smoothly-varying background of approximately 100 pptv, which we attribute to I2 from other more

  4. Fast and Accurate Collocation of the Visible Infrared Imaging Radiometer Suite Measurements with Cross-Track Infrared Sounder

    Directory of Open Access Journals (Sweden)

    Likun Wang

    2016-01-01

    Full Text Available Given the fact that Cross-track Infrared Sounder (CrIS and the Visible Infrared Imaging Radiometer Suite (VIIRS are currently onboard the Suomi National Polar-orbiting Partnership (Suomi NPP satellite and will continue to be carried on the same platform as future Joint Polar Satellite System (JPSS satellites for the next decade, it is desirable to develop a fast and accurate collocation scheme to collocate VIIRS products and measurements with CrIS for applications that rely on combining measurements from two sensors such as inter-calibration, geolocation assessment, and cloud detection. In this study, an accurate and fast collocation method to collocate VIIRS measurements within CrIS instantaneous field of view (IFOV directly based on line-of-sight (LOS pointing vectors is developed and discussed in detail. We demonstrate that this method is not only accurate and precise from a mathematical perspective, but also easy to implement computationally. More importantly, with optimization, this method is very fast and efficient and thus can meet operational requirements. Finally, this collocation method can be extended to a wide variety of sensors on different satellite platforms.

  5. Fast rise of broadly cross-reactive antibodies after boosting long-lived human memory B cells primed by an MF59 adjuvanted prepandemic vaccine

    Science.gov (United States)

    Galli, Grazia; Hancock, Kathy; Hoschler, Katja; DeVos, Joshua; Praus, Michaela; Bardelli, Monia; Malzone, Carmine; Castellino, Flora; Gentile, Chiara; McNally, Teresa; Del Giudice, Giuseppe; Banzhoff, Angelika; Brauer, Volker; Montomoli, Emanuele; Zambon, Maria; Katz, Jacqueline; Nicholson, Karl; Stephenson, Iain

    2009-01-01

    Proactive priming before the next pandemic could induce immune memory responses to novel influenza antigens. In an open-label study, we analyzed B cell memory and antibody responses of 54 adults who received 2 7.5-μg doses of MF59-adjuvanted A/Vietnam/1194/2004 clade 1 (H5N1) vaccine. Twenty-four subjects had been previously primed with MF59-adjuvanted or plain clade 0-like A/duck/Singapore/1997 (H5N3) vaccine during 1999–2001. The prevaccination frequency of circulating memory B cells reactive to A/Vietnam/1194/2004 was low in both primed and unprimed individuals. However, at day 21 after boosting, MF59-adjuvanted primed subjects displayed a higher frequency of H5N1-specific memory B cells than plain-primed or unprimed subjects. The immune memory was rapidly mobilized by a single vaccine administration and resulted in high titers of neutralizing antibodies to antigenically diverse clade 0, 1, and 2 H5N1 viruses already at day 7. In general, postvaccination antibody titers were significantly higher in primed subjects than in unprimed subjects. Subjects primed with MF59-adjuvanted vaccine responded significantly better than those primed with plain vaccine, most notably in early induction and duration of cross-reacting antibody responses. After 6 months, high titers of cross-reactive antibody remained detectable among MF59-primed subjects. We conclude that distant priming with clade 0-like H5N3 induces a pool of cross-reactive memory B cells that can be boosted rapidly years afterward by a mismatched MF59-adjuvanted vaccine to generate high titers of cross-reactive neutralizing antibodies rapidly. These results suggest that pre-pandemic vaccination strategies should be considered. PMID:19416838

  6. Development of a very fast spectral response measurement system for analysis of hydrogenated amorphous silicon solar cells and modules

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.A., E-mail: jose.rodriguez@tsolar.eu [Dept. Technology, Development and Innovation, T-Solar Global S.A., Parque Tecnologico de Galicia, Avda. de Vigo 5, E-32900 San Cibrao das Vinas (Ourense) (Spain); Fortes, M. [Departamento de Electronica e Computacion, Universidade de Santiago de Compostela, 15782 Santiago de Compostela (Spain); Alberte, C.; Vetter, M.; Andreu, J. [Dept. Technology, Development and Innovation, T-Solar Global S.A., Parque Tecnologico de Galicia, Avda. de Vigo 5, E-32900 San Cibrao das Vinas (Ourense) (Spain)

    2013-01-01

    Highlights: Black-Right-Pointing-Pointer Spectral response equipment for measuring a-Si:H solar cells in a few seconds. Black-Right-Pointing-Pointer Equipment based on 16 LEDs with simultaneous illumination of the solar cell. Black-Right-Pointing-Pointer The current generated by each LED is analyzed by a Fast Fourier Transform. Black-Right-Pointing-Pointer Cheap equipment without lock-in technology for the current measurement. Black-Right-Pointing-Pointer Measurement error vs. conventional measurement less than 1% in J{sub sc}. - Abstract: An important requirement for a very fast spectral response measurement system is the simultaneous illumination of the solar cell at multiple well defined wavelengths. Nowadays this can be done by means of light emitting diodes (LEDs) available for a multitude of wavelengths. For the purpose to measure the spectral response (SR) of amorphous silicon solar cells a detailed characterization of LEDs emitting in the wavelength range from 300 nm to 800 nm was performed. In the here developed equipment the LED illumination is modulated in the frequency range from 100 Hz to 200 Hz and the current generated by each LED is analyzed by a Fast Fourier Transform (FFT) to determine the current component corresponding to each wavelength. The equipment provides a signal to noise ratio of 2-4 orders of magnitude for individual wavelengths resulting in a precise measurement of the SR over the whole wavelength range. The difference of the short circuit current determined from the SR is less than 1% in comparison to a conventional system with monochromator.

  7. Biosphere-atmosphere exchange of reactive nitrogen and greenhouse gases at the NitroEurope core flux measurement sites: Measurement strategy and first data sets

    DEFF Research Database (Denmark)

    Skiba, U.; Drewer, J.; Tang, Y.S.

    2009-01-01

    -agricultural ecosystems. The NO and N2O emission ratio is influenced by soil type and precipitation. First budgets of reactive N entering and leaving the ecosystem and of net greenhouse gas exchange are outlined. Further information on rates of denitrification to N2 and biological N2 fixation is required to complete...... by a network of low-cost flux measurements (Level-2, 9 sites) and a network to infer reactive N fluxes at 58 sites (Level-1), for comparison with carbon (C) flux measurements. Measurements at the Level-3 sites include high resolution N2O, NO (also CH4, CO2) fluxes, wet and dry N deposition, leaching of N and C...... and N transformations in plant, litter and soil. Results for the first 11 months (1.8.2006 to 30.6.2007) suggest that the grasslands are the largest source of N2O, that forests are the largest source of NO and sink of CH4 and that N deposition rates influence NO and N2O fluxes in non...

  8. Fast and accurate measurement of on-axis gain and on-axis polarization at a finite distance

    DEFF Research Database (Denmark)

    Pivnenko, S.; Breinbjerg, O.

    2013-01-01

    In this paper, a technique for fast and accurate measurement of on-axis gain and on-axis polarization characteristics of antennas, such as Standard Gain Horns, compact range feed horns, and near-field probes, is described. The proposed gain determination procedure is a modification of the far......-field substitution technique in which the measurement distance is defined between the phase centres of the antennas. The location of the phase centre of the antenna under test (AUT) is found from a quick pattern measurement consisting of only four cuts including the main and diagonal planes. Additionally, in order...... to reduce the amount of measurement data and thus measurement time, the phase centre location is found on a sparse frequency grid and the values in the intermediate points are found by interpolation. The antenna polarization is determined from the amplitude/phase frequency sweeps with two orthogonal AUT...

  9. Edge turbulence effect on ultra-fast swept reflectometry core measurements in tokamak plasmas

    Science.gov (United States)

    Zadvitskiy, G. V.; Heuraux, S.; Lechte, C.; Hacquin, S.; Sabot, R.

    2018-02-01

    Ultra-fast frequency-swept reflectometry (UFSR) enables one to provide information about the turbulence radial wave-number spectrum and perturbation amplitude with good spatial and temporal resolutions. However, a data interpretation of USFR is quiet tricky. An iterative algorithm to solve this inverse problem was used in past works, Gerbaud (2006 Rev. Sci. Instrum. 77 10E928). For a direct solution, a fast 1D Helmholtz solver was used. Two-dimensional effects are strong and should be taken into account during data interpretation. As 2D full-wave codes are still too time consuming for systematic application, fast 2D approaches based on the Born approximation are of prime interest. Such methods gives good results in the case of small turbulence levels. However in tokamak plasmas, edge turbulence is usually very strong and can distort and broaden the probing beam Sysoeva et al (2015 Nucl. Fusion 55 033016). It was shown that this can change reflectometer phase response from the plasma core. Comparison between 2D full wave computation and the simplified Born approximation was done. The approximated method can provide a right spectral shape, but it is unable to describe a change of the spectral amplitude with an edge turbulence level. Computation for the O-mode wave with the linear density profile in the slab geometry and for realistic Tore-Supra density profile, based on the experimental data turbulence amplitude and spectrum, were performed to investigate the role of strong edge turbulence. It is shown that the spectral peak in the signal amplitude variation spectrum which rises with edge turbulence can be a signature of strong edge turbulence. Moreover, computations for misaligned receiving and emitting antennas were performed. It was found that the signal amplitude variation peak changes its position with a receiving antenna poloidal displacement.

  10. Effects of resistive magnetic field on fast electron divergence measured in experiment

    Czech Academy of Sciences Publication Activity Database

    Yang, H.X.; Zhuo, H.B.; Ma, Y.Y.; Xu, H.; Yu, T.P.; Zou, D.B.; Ge, Z.Y.; Xu, B.B.; Zhu, Q.J.; Shao, F.Q.; Borghesi, Marco

    2015-01-01

    Roč. 57, č. 2 (2015), s. 025011 ISSN 0741-3335 R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE2.3.20.0279 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; LaserZdroj (OP VK 3)(XE) CZ.1.07/2.3.00/20.0279 Institutional support: RVO:68378271 Keywords : fast electron * divergence measument * resistive magnetic field * laser-plasma interactions * short-pulse * acceleration Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.404, year: 2015

  11. Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy.

    Science.gov (United States)

    Sakurai, Yoshinori; Tanaka, Hiroki; Kondo, Natsuko; Kinashi, Yuko; Suzuki, Minoru; Masunaga, Shinichiro; Ono, Koji; Maruhashi, Akira

    2015-11-01

    Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a "dual phantom technique" for measuring the fast neutron component of dose is reported. One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % 6LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % 6LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the

  12. Measuring reactive nitrogen emissions from point sources using visible spectroscopy from aircraft.

    Science.gov (United States)

    Melamed, M L; Solomon, S; Daniel, J S; Langford, A O; Portmann, R W; Ryerson, T B; Nicks, D K; McKeen, S A

    2003-02-01

    Accurate measurements of nitrogen dioxide (NO2), a key trace gas in the formation and destruction of tropospheric ozone, are important in studies of urban pollution. Nitrogen dioxide column abundances were measured during the Texas Air Quality Study 2000 using visible absorption spectroscopy from an aircraft. The method allows for quantification of the integrated total number of nitrogen dioxide molecules in the polluted atmosphere and is hence a useful tool for measuring plumes of this key trace gas. Further, we show how such remote-sensing observations can be used to obtain information on the fluxes of nitrogen dioxide into the atmosphere with unique flexibility in terms of aircraft altitude, and the height and extent of mixing of the boundary layer. Observations of nitrogen dioxide plumes downwind of power plants were used to estimate the flux of nitrogen oxide emitted from several power plants in the Houston and Dallas metropolitan areas and in North Carolina. Measurements taken over the city of Houston were also employed to infer the total flux from the city as a whole.

  13. A novel fast-scanning microwave heterodyne radiometer system for electron cyclotron emission measurements in the HT-7 superconducting tokamak

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Wan, Y.X.; Xie, J.K.; Luo, J.R.; Li, J.G.; Kuang, G.L.; Gao, X.; Zhang, X.D.; Wan, B.N.; Wang, K.J.; Mao, J.S.; Gong, X.Z.; Qin, P.J.

    2000-01-01

    Two sets of fast-scanning microwave heterodyne radiometer receiver systems employing backward-wave oscillators in the 78-118 GHz and 118-178 GHz ranges were developed for electron cyclotron emission measurements (ECE) on the HT-7 superconducting tokamak. The double-sideband radiometer in the 78-118 GHz range measures 16 ECE frequency points with a scanning period of 0.65 ms. The novel design of the 2 mm fast-scanning heterodyne radiometer in the 118-178 GHz range enables the unique system to measure 48 ECE frequency points in 0.65 ms periodically. The plasma profile consistency in reproducible ohmic plasmas was used to relatively calibrate each channel by changing the toroidal magnetic field shot-by-shot. The absolute temperature value was obtained by a comparison with the results from the soft x-ray pulse height analysis measurements and Thomson scattering system. A preliminary temperature profile measurement result in pellet injection plasma is presented. (author)

  14. Sub-millisecond electron density profile measurement at the JET tokamak with the fast lithium beam emission spectroscopy system

    Science.gov (United States)

    Réfy, D. I.; Brix, M.; Gomes, R.; Tál, B.; Zoletnik, S.; Dunai, D.; Kocsis, G.; Kálvin, S.; Szabolics, T.; JET Contributors

    2018-04-01

    Diagnostic alkali atom (e.g., lithium) beams are routinely used to diagnose magnetically confined plasmas, namely, to measure the plasma electron density profile in the edge and the scrape off layer region. A light splitting optics system was installed into the observation system of the lithium beam emission spectroscopy diagnostic at the Joint European Torus (JET) tokamak, which allows simultaneous measurement of the beam light emission with a spectrometer and a fast avalanche photodiode (APD) camera. The spectrometer measurement allows density profile reconstruction with ˜10 ms time resolution, absolute position calculation from the Doppler shift, spectral background subtraction as well as relative intensity calibration of the channels for each discharge. The APD system is capable of measuring light intensities on the microsecond time scale. However ˜100 μs integration is needed to have an acceptable signal to noise ratio due to moderate light levels. Fast modulation of the beam up to 30 kHz is implemented which allows background subtraction on the 100 μs time scale. The measurement covers the 0.9 localized modes.

  15. Analysis of C/E results of fission rate ratio measurements in several fast lead VENUS-F cores

    Directory of Open Access Journals (Sweden)

    Kochetkov Anatoly

    2017-01-01

    Full Text Available During the GUINEVERE FP6 European project (2006–2011, the zero-power VENUS water-moderated reactor was modified into VENUS-F, a mock-up of a lead cooled fast spectrum system with solid components that can be operated in both critical and subcritical mode. The Fast Reactor Experiments for hybrid Applications (FREYA FP7 project was launched in 2011 to support the designs of the MYRRHA Accelerator Driven System (ADS and the ALFRED Lead Fast Reactor (LFR. Three VENUS-F critical core configurations, simulating the complex MYRRHA core design and one configuration devoted to the LFR ALFRED core conditions were investigated in 2015. The MYRRHA related cores simulated step by step design peculiarities like the BeO reflector and in pile sections. For all of these cores the fuel assemblies were of a simple design consisting of 30% enriched metallic uranium, lead rodlets to simulate the coolant and Al2O3 rodlets to simulate the oxide fuel. Fission rate ratios of minor actinides such as Np-237, Am-241 as well as Pu-239, Pu-240, Pu-242 and U-238 to U-235 were measured in these VENUS-F critical assemblies with small fission chambers in specially designed locations, to determine the spectral indices in the different neutron spectrum conditions. The measurements have been analyzed using advanced computational tools including deterministic and stochastic codes and different nuclear data sets like JEFF-3.1, JEFF-3.2, ENDF/B7.1 and JENDL-4.0. The analysis of the C/E discrepancies will help to improve the nuclear data in the specific energy region of fast neutron reactor spectra.

  16. Analysis of C/E results of fission rate ratio measurements in several fast lead VENUS-F cores

    Science.gov (United States)

    Kochetkov, Anatoly; Krása, Antonín; Baeten, Peter; Vittiglio, Guido; Wagemans, Jan; Bécares, Vicente; Bianchini, Giancarlo; Fabrizio, Valentina; Carta, Mario; Firpo, Gabriele; Fridman, Emil; Sarotto, Massimo

    2017-09-01

    During the GUINEVERE FP6 European project (2006-2011), the zero-power VENUS water-moderated reactor was modified into VENUS-F, a mock-up of a lead cooled fast spectrum system with solid components that can be operated in both critical and subcritical mode. The Fast Reactor Experiments for hybrid Applications (FREYA) FP7 project was launched in 2011 to support the designs of the MYRRHA Accelerator Driven System (ADS) and the ALFRED Lead Fast Reactor (LFR). Three VENUS-F critical core configurations, simulating the complex MYRRHA core design and one configuration devoted to the LFR ALFRED core conditions were investigated in 2015. The MYRRHA related cores simulated step by step design peculiarities like the BeO reflector and in pile sections. For all of these cores the fuel assemblies were of a simple design consisting of 30% enriched metallic uranium, lead rodlets to simulate the coolant and Al2O3 rodlets to simulate the oxide fuel. Fission rate ratios of minor actinides such as Np-237, Am-241 as well as Pu-239, Pu-240, Pu-242 and U-238 to U-235 were measured in these VENUS-F critical assemblies with small fission chambers in specially designed locations, to determine the spectral indices in the different neutron spectrum conditions. The measurements have been analyzed using advanced computational tools including deterministic and stochastic codes and different nuclear data sets like JEFF-3.1, JEFF-3.2, ENDF/B7.1 and JENDL-4.0. The analysis of the C/E discrepancies will help to improve the nuclear data in the specific energy region of fast neutron reactor spectra.

  17. Dynamic measurements at THz frequencies with a fast rotary delay line

    Science.gov (United States)

    Guerboukha, Hichem; Markov, Andrey; Qu, Hang; Skorobogatiy, Maksim

    2016-02-01

    Fabrication, characterization, and applications of a fast rotary linear optical delay line (FRLODL) for THz time-domain spectroscopy are presented. The FRLODL features two reflective surfaces with spatially separated incoming and outgoing beams. It has been manufactured using CNC machining. A linear dependence of the optical delay on the rotation angle allows a straightforward extraction of the conversion factor between the acquisition time (in ms) and the terahertz pulse time (in ps). The FRLODL has been tested using rotation speeds of up to 48 Hz, corresponding to an acquisition rate of up to 192 Hz with four blades incorporated on the same disk. At high speeds we observe a decrease of the bandwidth due to the limitations of the electronics, in particular, the transimpedance amplifier. An error analysis is performed by experimentally evaluating the signal-to-noise ratio and the dynamic range. With regard to the applications of the FRLODL, we first present observation of the evaporation of liquids, namely water, acetone and methanol. We then demonstrate monitoring of the spray painting process. Finally, detection of fast moving objects at 1 m/s and their thickness characterization are presented.

  18. Single-well reactive tracer test and stable isotope analysis for determination of microbial activity in a fast hydrocarbon-contaminated aquifer.

    Science.gov (United States)

    Burbery, L; Cassiani, G; Andreotti, G; Ricchiuto, T; Semple, K T

    2004-05-01

    Single-well reactive tracer tests, such as the push-pull test are useful tools for characterising in-situ bioattenuation processes in contaminated aquifers. However, the analytical models that are used to interpret push-pull data may be over-simplified, and potentially overlook important processes responsible for the frequent discrepancy between predicted and observed results obtained from push-pull tests. In this study, the limitations underlying the push-pull test methodology were investigated and were supported with results from a push-pull test conducted in a sulphate-reducing aquifer contaminated by crude oil. Poor (20% mass recoveries were achieved. Push-pull test data collected from sulphate-reducing aquifers indicate that the assumption of a well-mixed batch reactor system is incorrect and that reaction rates obtained from push-pull tests in such systems may be affected by the extraction regime implemented. Evidence of microbial respiration of the reactive tracer was provided by stable sulphur isotope analysis, from which an isotope fractionation factor of +9.9 +/- 8.1 per thousand was estimated. The stable isotope data support the argument that reaction rates calculated using push-pull tests are not uniformly distributed in space and time and are likely to be influenced by heterogeneities in the flow field.

  19. Measurement of Moments and Radii of Light Nuclei by Collinear Fast-Beam Laser Spectroscopy and $\\beta$-NMR Spectroscopy

    CERN Multimedia

    Marinova, K P

    2002-01-01

    Nuclear Moments and radii of light unstable isotopes are investigated by applying different high-sensitivity and high-resolution techniques based on collinear fast-beam laser spectroscopy. A study of nuclear structure in the sd shell is performed on neon isotopes in the extended chain of $^{17-28}$Ne, in particular on the proton-halo candidate $^{17}$Ne. Measurements of hyperfine structure and isotope shift have become possible by introducing an ultra-sensitive non-optical detection method which is based on optical pumping, state-selective collisional ionization and $\\beta$-activity counting. The small effect of nuclear radii on the optical isotope shifts of light elements requires very accurate measurements. The errors are dominated by uncertainties of the Doppler shifts which are conventionally determined from precisely measured acceleration voltages. These uncertainties are removed by measuring the beam energy with simultaneous excitation of two optical lines in parallel / antiparallel beam configuration. ...

  20. An aircraft-borne chemical ionization – ion trap mass spectrometer (CI-ITMS for fast PAN and PPN measurements

    Directory of Open Access Journals (Sweden)

    H. Schlager

    2011-02-01

    Full Text Available An airborne chemical ionization ion trap mass spectrometer instrument (CI-ITMS has been developed for tropospheric and stratospheric fast in-situ measurements of PAN (peroxyacetyl nitrate and PPN (peroxypropionyl nitrate. The first scientific deployment of the FASTPEX instrument (FASTPEX = Fast Measurement of Peroxyacyl nitrates took place in the Arctic during 18 missions aboard the DLR research aircraft Falcon, within the framework of the POLARCAT-GRACE campaign in the summer of 2008. The FASTPEX instrument is described and characteristic properties of the employed ion trap mass spectrometer are discussed. Atmospheric data obtained at altitudes of up to ~12 km are presented, from the boundary layer to the lowermost stratosphere. Data were sampled with a time resolution of 2 s and a 2σ detection limit of 25 pmol mol−1. An isotopically labelled standard was used for a permanent on-line calibration. For this reason the accuracy of the PAN measurements is better than ±10% for mixing ratios greater than 200 pmol mol−1. PAN mixing ratios in the summer Arctic troposphere were in the order of a few hundred pmol mol−1 and generally correlated well with CO. In the Arctic boundary layer and lowermost stratosphere smaller PAN mixing ratios were observed due to a combination of missing local sources of PAN precursor gases and efficient removal processes (thermolysis/photolysis. PPN, the second most abundant PAN homologue, was measured simultaneously. Observed PPN/PAN ratios range between ~0.03 and 0.3.

  1. On-road Emissions of Reactive Nitrogen through In-situ, Mobile Measurements

    Science.gov (United States)

    Sun, K.; Tao, L.; Pan, D.; Golston, L.; Miller, D. J.; Zondlo, M. A.

    2014-12-01

    Ammonia (NH3) is a key precursor to atmospheric fine particulate matter (PM2.5), with strong implications for regional air quality and global climate change. Existing atmospheric measurements suggest that urban traffic may provide significant amount of NH3. NH3 emissions in urban areas may cause greater impact on air quality and human health, because other aerosol tracers, like NO and NO2, are emitted by similar on-road sources. However, the on-road NH3 emission inventories are subject to significant uncertainties. A mobile platform is developed by mounting multiple portable (total power ~ 100 W, weight ~ 25 kg), high-resolution (10 Hz), open-path sensors on top of a passenger car. On-road NH3 emissions are quantified in the real-world driving conditions by synchronized NH3, CO, and CO2 measurements. The mobile platform has covered over 16,000 km in the US and China since 2013. The total on-road sampling time is over 300 hours. Major US metropolitan areas that have been sampled include LA, SF, Houston, Philadelphia, and Denver. Three Chinese megacities (Beijing, Baoding, and Shijiazhuang) were sampled in both 2013 and 2014. The average emission factors (grams of NH3 emitted per kilogram of fuel) range from 0.3 to 0.5 g/kg. Different methodologies were compared, including on-road emission ratios, tunnel measurements, and city-scale gradient measurements. These methodologies yielded the same emission factor for Houston (0.4±0.05 g/kg) within the sampling uncertainties and showed that multiple approaches are consistent with one another. The observed NH3 emission ratios indicate that National Emisison Inventory (NEI) underestimates on-road NH3 emissions by up to 50% in some major urban areas. On-road NH3 emission factors show higher values in both stop-and-go driving conditions and freeway speeds with a minimum near 70 km/h. This is consistent with another observation that the emission factors in urban traffic are generally larger than suburban traffic. Road gradient

  2. Fast freeze-drying cycle design and optimization using a PAT based on the measurement of product temperature.

    Science.gov (United States)

    Bosca, Serena; Barresi, Antonello A; Fissore, Davide

    2013-10-01

    This paper is focused on the use of an innovative Process Analytical Technology for the fast design and optimization of freeze-drying cycles for pharmaceuticals. The tool is based on a soft-sensor, a device that uses the experimental measure of product temperature during freeze-drying, a mathematical model of the process, and the Extended Kalman Filter algorithm to estimate the sublimation flux, the residual amount of ice in the vial, and some model parameters (heat and mass transfer coefficients). The accuracy of the estimations provided by the soft-sensor has been shown using as test case aqueous solutions containing different excipients (sucrose, polyvinylpyrrolidone), processed at various operating conditions, pointing out that the soft-sensor allows a fast estimation of model parameters and product dynamics without involving expensive hardware or time consuming analysis. The possibility of using the soft-sensor to calculate in-line (or off-line) the design space of the primary drying phase is here presented and discussed. Results evidences that by this way, it is possible to identify the values of the heating fluid temperature that maintain product temperature below the limit value, as well as the operating conditions that maximize the sublimation flux. Various experiments have been carried out to test the effectiveness of the proposed approach for a fast design of the cycle, evidencing that drying time can be significantly reduced, without impairing product quality. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Development and Implementation of a Technique for Fast Five-Hole Probe Measurements Downstream of a Linear Cascade

    Directory of Open Access Journals (Sweden)

    Reinaldo A. Gomes

    2018-02-01

    Full Text Available Flow measurement using a linear compressor or turbine cascade is a well-established technique to characterize the flow in turbomachines with a certain degree of abstraction. A common way to obtain a general characterization of the flow is to measure the flow downstream of the cascade with a five-hole probe, obtaining, e.g., total pressure losses and flow turning. Pneumatic five-hole probes are used to capture steady or time-averaged flow quantities, if not specified otherwise. In dependency of probe geometry, measurement set-up and flow properties, such measurements can be very time-consuming. Various techniques, in order to decrease the measurement time, are proposed in literature but for certain applications the efforts required to implement such techniques can outweigh the enhanced measurement speed. In this paper, methods proposed by other authors are combined and extended to allow for fast or transient five-hole probe measurements at strongly varying flow conditions. The effectiveness of this method is presented for flow measurements downstream of a compressor cascade with attached and stalled flow (by varying the Reynolds number as well as with steady and periodically unsteady inflow. The new method allows to reduce the measurement time by up to 90 percent without compromising measurement accuracy. In fact, due to higher spatial resolution, the flow downstream of the cascade can be better resolved with the new method.

  4. Measurements of reactive nitrogen produced by tropical thunderstorms during BIBLE-C

    Science.gov (United States)

    Koike, M.; Kondo, Y.; Kita, K.; Takegawa, N.; Nishi, N.; Kashihara, T.; Kawakami, S.; Kudoh, S.; Blake, D.; Shirai, T.; Liley, B.; Ko, M.; Miyazaki, Y.; Kawasaki, Z.; Ogawa, T.

    2007-09-01

    The Biomass Burning and Lightning Experiment phase C (BIBLE-C) aircraft mission was carried out near Darwin, Australia (12°S, 131°E) in December 2000. This was the first aircraft experiment designed to estimate lightning NO production rates in the tropics, where production is considered to be most intense. During the two flights (flights 10 and 13 made on December 9 and 11-12, respectively) enhancements of NOx (NO + NO2) up to 1000 and 1600 parts per trillion by volume (pptv, 10-s data) were observed at altitudes between 11.5 and 14 km. The Geostationary Meteorological Satellite (GMS) cloud (brightness temperature) data and ground-based lightning measurements by the Global Positioning and Tracking System (GPATS) indicate that there were intensive lightning events over the coast of the Gulf of Carpentaria, which took place upstream from our measurement area 10 to 14 h prior to the measurements. For these two flights, air in which NOx exceeded 100 pptv extended over 620 × 140 and 400 × 170 km2 (wind direction × perpendicular direction), respectively, suggesting a significant impact of lightning NO production on NOx levels in the tropics. We estimate the amount of NOx observed between 11.5 and 14 km produced by the thunderstorms to be 3.3 and 1.8 × 1029 NO molecules for flights 10 and 13, respectively. By using the GPATS lightning flash count data, column NO production rates are estimated to be 1.9-4.4 and 21-49 × 1025 NO molecules per single flash for these two flight data sets. In these estimations, it is assumed that the column NO production between 0 and 16 km is greater than the observed values between 11.5 and 14 km by a factor of 3.2, which is derived using results reported by Pickering et al. (1998). There are however large uncertainties in the GPATS lightning data in this study and care must be made when the production rates are referred. Uncertainties in these estimates are discussed. The impact on the ozone production rate is also described.

  5. Noninvasive and fast measurement of blood glucose in vivo by near infrared (NIR) spectroscopy

    Science.gov (United States)

    Jintao, Xue; Liming, Ye; Yufei, Liu; Chunyan, Li; Han, Chen

    2017-05-01

    This research was to develop a method for noninvasive and fast blood glucose assay in vivo. Near-infrared (NIR) spectroscopy, a more promising technique compared to other methods, was investigated in rats with diabetes and normal rats. Calibration models are generated by two different multivariate strategies: partial least squares (PLS) as linear regression method and artificial neural networks (ANN) as non-linear regression method. The PLS model was optimized individually by considering spectral range, spectral pretreatment methods and number of model factors, while the ANN model was studied individually by selecting spectral pretreatment methods, parameters of network topology, number of hidden neurons, and times of epoch. The results of the validation showed the two models were robust, accurate and repeatable. Compared to the ANN model, the performance of the PLS model was much better, with lower root mean square error of validation (RMSEP) of 0.419 and higher correlation coefficients (R) of 96.22%.

  6. Measuring modules for the research of compensators of reactive power with voltage stabilization in MATLAB

    Science.gov (United States)

    Vlasayevsky, Stanislav; Klimash, Stepan; Klimash, Vladimir

    2017-10-01

    A set of mathematical modules was developed for evaluation the energy performance in the research of electrical systems and complexes in the MatLab. In the electrotechnical library SimPowerSystems of the MatLab software, there are no measuring modules of energy coefficients characterizing the quality of electricity and the energy efficiency of electrical apparatus. Modules are designed to calculate energy coefficients characterizing the quality of electricity (current distortion and voltage distortion) and energy efficiency indicators (power factor and efficiency) are presented. There are described the methods and principles of building the modules. The detailed schemes of modules built on the elements of the Simulink Library are presented, in this connection, these modules are compatible with mathematical models of electrical systems and complexes in the MatLab. Also there are presented the results of the testing of the developed modules and the results of their verification on the schemes that have analytical expressions of energy indicators.

  7. Buckling measurement in the IPEN/MB-01 nuclear reactor in cylindrical configuration of minor excess of reactivity

    Energy Technology Data Exchange (ETDEWEB)

    Purgato, Rafael Turrini; Bitelli, Ulysses d' Utra; Aredes, Vitor Ottoni; Silva, Alexandre F. Povoa da; Santos, Diogo Feliciano dos; Lima, Ana Cecilia de Souza, E-mail: ubitelli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This work presents the results of experimental Buckling in the IPEN/MB-01 nuclear reactor in its cylindrical configuration with 28 fuel rods along its diameter. The IPEN/MB-01 is a zero power reactor designed to operate at a maximum power of 100 watts. It is a versatile nuclear facility, which allows for the simulation of all the characteristics of a nuclear power reactor making it an ideal test bed for this kind of measurement. A mapping of neutron flux inside the reactor is carried out in order to determine the total Buckling of the cylindrical configuration. The reactor was operated for one hour. Then, the activity of the fuel rods is measured by gamma ray spectrometry using a HPGe solid state detector and a suitable rod scanner. Photon energies of 276.6keV from {sup 239}Np (neutron capture (n,?) nuclear reaction) and 293.3keV from {sup 143}Ce (fission (n,f) nuclear reaction on both {sup 238}U and {sup 235}U) , are respectively along both axial and radial directions. Other measurements are performed using gold wires and foils along radial and axial directions of the reactor core. The three methods above resulted in a weighted average value of 93.18 ± 8.47 m-2 for the Total Buckling of this cylindrical core configuration with 28 control rods along its diameter with 568 fuel rods and only 271 pcm of excess reactivity. (author)

  8. Measurement of the CNA I's (Atucha I nuclear power plant) control rods reactivity during its commissioning on January 8th, 1990

    International Nuclear Information System (INIS)

    Waldman, R.M.; Gomez, A.

    1990-01-01

    Measurements were made on integral and differential calibration of rod 16, fuel racks RG and R3 and extinction reactivity during Atucha I nuclear power plant's commissioning on January 8th., 1990. These were the first physical measurements performed after the first critical nuclear power plant's commissioning. (Author) [es

  9. In situ measurements and modeling of reactive trace gases in a small biomass burning plume

    Directory of Open Access Journals (Sweden)

    M. Müller

    2016-03-01

    Full Text Available An instrumented NASA P-3B aircraft was used for airborne sampling of trace gases in a plume that had emanated from a small forest understory fire in Georgia, USA. The plume was sampled at its origin to derive emission factors and followed  ∼ 13.6 km downwind to observe chemical changes during the first hour of atmospheric aging. The P-3B payload included a proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS, which measured non-methane organic gases (NMOGs at unprecedented spatiotemporal resolution (10 m spatial/0.1 s temporal. Quantitative emission data are reported for CO2, CO, NO, NO2, HONO, NH3, and 16 NMOGs (formaldehyde, methanol, acetonitrile, propene, acetaldehyde, formic acid, acetone plus its isomer propanal, acetic acid plus its isomer glycolaldehyde, furan, isoprene plus isomeric pentadienes and cyclopentene, methyl vinyl ketone plus its isomers crotonaldehyde and methacrolein, methylglyoxal, hydroxy acetone plus its isomers methyl acetate and propionic acid, benzene, 2,3-butanedione, and 2-furfural with molar emission ratios relative to CO larger than 1 ppbV ppmV−1. Formaldehyde, acetaldehyde, 2-furfural, and methanol dominated NMOG emissions. No NMOGs with more than 10 carbon atoms were observed at mixing ratios larger than 50 pptV ppmV−1 CO. Downwind plume chemistry was investigated using the observations and a 0-D photochemical box model simulation. The model was run on a nearly explicit chemical mechanism (MCM v3.3 and initialized with measured emission data. Ozone formation during the first hour of atmospheric aging was well captured by the model, with carbonyls (formaldehyde, acetaldehyde, 2,3-butanedione, methylglyoxal, 2-furfural in addition to CO and CH4 being the main drivers of peroxy radical chemistry. The model also accurately reproduced the sequestration of NOx into peroxyacetyl nitrate (PAN and the OH-initiated degradation of furan and 2-furfural at an average OH concentration of 7.45 ± 1

  10. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering

    DEFF Research Database (Denmark)

    Bindslev, Henrik; Nielsen, Stefan Kragh; Porte, L.

    2007-01-01

    ) and the slowdown after switch off of NBI are measured. The turn on phase of the NBI has, furthermore, been measured in plasmas with a range of electron densities and temperatures. All of these measurements are shown to be in good agreement with simple Fokker-Planck modelling. Bulk ion rotation velocity is also...

  11. Kinetic dissolution of carbonates and Mn oxides in acidic water: Measurement of in situ field rates and reactive transport modeling

    Science.gov (United States)

    Brown, J.G.; Glynn, P.D.

    2003-01-01

    The kinetics of carbonate and Mn oxide dissolution under acidic conditions were examined through the in situ exposure of pure phase samples to acidic ground water in Pinal Creek Basin, Arizona. The average long-term calculated in situ dissolution rates for calcite and dolomite were 1.65??10-7 and 3.64??10-10 mmol/(cm2 s), respectively, which were about 3 orders of magnitude slower than rates derived in laboratory experiments by other investigators. Application of both in situ and lab-derived calcite and dolomite dissolution rates to equilibrium reactive transport simulations of a column experiment did not improve the fit to measured outflow chemistry: at the spatial and temporal scales of the column experiment, the use of an equilibrium model adequately simulated carbonate dissolution in the column. Pyrolusite (MnO2) exposed to acidic ground water for 595 days increased slightly in weight despite thermodynamic conditions that favored dissolution. This result might be related to a recent finding by another investigator that the reductive dissolution of pyrolusite is accompanied by the precipitation of a mixed Mn-Fe oxide species. In PHREEQC reactive transport simulations, the incorporation of Mn kinetics improved the fit between observed and simulated behavior at the column and field scales, although the column-fitted rate for Mn-oxide dissolution was about 4 orders of magnitude greater than the field-fitted rate. Remaining differences between observed and simulated contaminant transport trends at the Pinal Creek site were likely related to factors other than the Mn oxide dissolution rate, such as the concentration of Fe oxide surface sites available for adsorption, the effects of competition among dissolved species for available surface sites, or reactions not included in the model.

  12. Towards Fast Measurement of the Electron Temperature in the SOL of ASDEX Upgrade Using Swept Langmuir Probes

    Czech Academy of Sciences Publication Activity Database

    Müller, H. W.; Adámek, Jiří; Horáček, Jan; Ionita, C.; Mehlmann, F.; Rohde, V.; Schrittwieser, R.

    2010-01-01

    Roč. 50, č. 9 (2010), s. 847-853 ISSN 0863-1042. [International Workshop on Electric Probes in Magnetized Plasmas/8th./. Innsbruck, 21.09.2009-24.09.2009] R&D Projects: GA AV ČR KJB100430901; GA ČR GA202/09/1467 Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamak * Langmuir probe * swept probe * ball-pen probe * fast temperature measurement * ELM Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.006, year: 2010 http://onlinelibrary.wiley.com/doi/10.1002/ctpp.201010144/pdf

  13. Investigation of atmospheric particle-bound reactive oxidative species (ROS): Their sources, characterization, and measurement

    Science.gov (United States)

    Venkatachari, Prasanna

    it possible for these species to bind onto particles forming fine particulate organic peroxides that concentrate on the particles and could deliver concentrated doses of ROS in vivo to tissue. The lack of a suitable method to measure ROS on a routine basis has resulted in no work being undertaken to assess the effects of particle-bound ROS on health effects. In order to fill this need, an automated monitor for the sampling of ambient aerosol and the measurement of concentrations of ROS on the sampled aerosol was developed. Potential methods to quantify ROS were compared in order to arrive at a suitable method to automate. The Dichlorofluorescein (DCFH) fluorescence method was found to be the most non-specific, and hence the best suited method for the automated monitor. An integrated sampling-analysis system was designed and constructed based on collection of atmospheric particles in an aqueous slurry, and subsequent detection of the ROS concentration of the slurry using the DCFH fluorescence method. The results of the lab-scale investigation of the ROS sampling-analysis system suggested that the prototype continuous system was capable of detecting particle-bound ROS, and accounting for short-term variabilitie

  14. Impact of Ramadan Intermittent Fasting on Oxidative Stress Measured by Urinary 15-F2t-Isoprostane

    Directory of Open Access Journals (Sweden)

    Mo'ez Al-Islam Ezzat Faris

    2012-01-01

    fast Ramadan were recruited. Urine and serum sampling and anthropometric and dietary assessments were conducted one week before Ramadan (T0, at the end of the third week of Ramadan (T1, and one month after Ramadan (T2. Biochemical measurements included urinary 15FIP, creatinine, and hematological indices. Results revealed that the urinary level of 15FIP measured at T0 was normal, while they showed a significantly (P<0.05 higher level when measured at T1 concomitant with a significant (P<0.05 increase in the body weight and total body fat percent. In conclusion, results suggest that increased body weight is associated with increased lipid peroxidation and oxidative stress, and the impact of RIF on oxidative stress is mediated by the changes in body weight at the end of the month.

  15. Fast laser systems for measuring the geometry of complex-shaped objects

    Science.gov (United States)

    Galiulin, Ravil M.; Galiulin, Rishat M.; Bakirov, J. M.; Vorontsov, A. V.; Ponomarenko, I. V.

    1999-01-01

    The technical characteristics, advantages and applications of an automated optoelectronic measuring system designed by 'Optel' company, State Aviation University of Ufa, are presented in this paper. The measuring apparatus can be applied for industrial development and research, for example, in rapid prototyping, and for obtaining geometrical parameters in medicine and criminalistics. It essentially is a non-contact and rapid scanning system, allowing measurements of complex shaped objects like metal and plastic workpieces or parts of human body.

  16. Impedance measurements on a fast transition-edge sensor for optical and near-infrared range

    International Nuclear Information System (INIS)

    Taralli, E; Portesi, C; Lolli, L; Monticone, E; Rajteri, M; Novikov, I; Beyer, J

    2010-01-01

    Impedance measurements of superconducting transition-edge sensors (TESs) are a powerful tool to obtain information about the TES thermal and electrical properties. We apply this technique to a 20 μm x 20 μm Ti/Au TES, suitable for application in the optical and near-infrared range, and extend the measurements up to 250 kHz in order to obtain a complete frequency response in the complex plane. From these measurements we obtain important thermal and electrical device parameters such as heat capacity C, thermal conductance G and effective thermal time constant τ eff that will be compared with the corresponding values obtained from noise measurements.

  17. Fast reactor programme

    International Nuclear Information System (INIS)

    Hoekstra, E.K.

    1976-11-01

    Estimated reactivity effects of fission products in the SNR-300 fast breeder are given. Neutron cross sections of 127 I and 129 I are also given. Results of the in-pile canning failure experiments on fuel pins R54-F35 and F39 are discussed. Sinter experiments using mixed UC-UN powders are reported. Results of tensile tests on high-dose and low-dose irradiated specimens of 18Cr1 1Ni stainless steel (DIN 1.4948) used in the SNR-300 reactor vessel are given. It is shown that the aerosol behaviour in condensing sodium vapour can be described by the same MADCA model developed for the decay of aerosols in condensing water vapour. Results of heat transfer measurements in the electrically heated 28-rod bundle under liquid-phase and subsequently under two-phase conditions are commented on

  18. Hair 32P measurement for body dose mapping in non-fatal exposures to fast neutrons.

    Science.gov (United States)

    Mianji, Fereidoun A; Jafari, Sheyda; Zaryouni, Saiedeh; Hajizadeh, Bardia

    2015-03-01

    Dosimetry bioassay methods are the backbone of a personal dosimetry in criticality accidents. Although methods like hair dosimetry and the use of activation foils (e.g., (32)S) have been employed for decades, capabilities of different techniques, effects of hair type and neutron spectrum on the dose response, sensitivity and uncertainties of different techniques, etc., need more investigations. For this reason, the use of the (32)S(n,p)(32)P reaction and hair samples for estimating non-fatal doses from fast neutrons was studied. The experiments were carried out with the hair samples attached on a RANDO phantom in a Cf-252 neutron field, in the dose range of about 0.05-1.15 Gy. In addition, the adequate post-accident preparation for hair samples including optimum conditioning and timing were investigated. Experimental results prove the good sensitivity and merit of the method for neutron quantification in the mentioned dose range for which other bioassay methods are of poor resolution and sensitivity. A rough estimation of the dose-response curve for Iranian hair was also derived.

  19. A new fast scanning system for the measurement of large angle tracks in nuclear emulsions

    Science.gov (United States)

    Alexandrov, A.; Buonaura, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Di Marco, N.; Galati, G.; Lauria, A.; Montesi, M. C.; Pupilli, F.; Shchedrina, T.; Tioukov, V.; Vladymyrov, M.

    2015-11-01

    Nuclear emulsions have been widely used in particle physics to identify new particles through the observation of their decays thanks to their unique spatial resolution. Nevertheless, before the advent of automatic scanning systems, the emulsion analysis was very demanding in terms of well trained manpower. Due to this reason, they were gradually replaced by electronic detectors, until the '90s, when automatic microscopes started to be developed in Japan and in Europe. Automatic scanning was essential to conceive large scale emulsion-based neutrino experiments like CHORUS, DONUT and OPERA. Standard scanning systems have been initially designed to recognize tracks within a limited angular acceptance (θ lesssim 30°) where θ is the track angle with respect to a line perpendicular to the emulsion plane. In this paper we describe the implementation of a novel fast automatic scanning system aimed at extending the track recognition to the full angular range and improving the present scanning speed. Indeed, nuclear emulsions do not have any intrinsic limit to detect particle direction. Such improvement opens new perspectives to use nuclear emulsions in several fields in addition to large scale neutrino experiments, like muon radiography, medical applications and dark matter directional detection.

  20. Status of measured neutron cross sections of transactinium isotopes in the fast region

    International Nuclear Information System (INIS)

    Igarasi, S.

    1976-01-01

    This paper reviews present status of measured neutron cross sections of transactinium isotopes from a viewpoint of requested data in application field of the nuclear data. The measured cross sections from 1 keV to 15 MeV are examined. Comparison between different data sets is mainly performed on the fission cross sections

  1. Measurement of flow by-passing and turbulent mixing in a model of a fast-reactor steam generator

    International Nuclear Information System (INIS)

    Little, A.J.; Fallows, T.; Central Electricity Generating Board, Leatherhead

    1989-01-01

    A description is given of measurements of edge by-pass velocities and turbulent mixing in a model of a fast reactor steam generator. The velocity measurements were carried out using a DANTEC triple-split fibre probe which allowed both the speed and flow angle of a velocity vector to be measured in a plane normal to the axis of the probe. The measurements revealed the presence of reverse flows in the by-pass and adjacent in-bank channels downstream of a grid plate. The magnitude of the by-pass flow was reduced considerably by the insertion of a kicker grid at the mid point between grid plates. Turbulent mixing measurements revealed that circumferential mixing in channels near the by-pass channel was up to 5 times greater than the radial mixing. The level of radial mixing at the edge of the bank was similar to that measured near the centre of the bank. A method of transposing mass diffusion measurements in air to thermal diffusivities of sodium is discussed. (orig.)

  2. A Fast, Portable, Fiber Optic Spectrofluorometer for Eddy Correlation Flux Measurement in the Aquatic Environment

    Science.gov (United States)

    Hu, I. H.; Senft-Grupp, S.; Hemond, H.

    2014-12-01

    The measurement of chemical fluxes between natural waters and their benthic sediments by most existing methods, such as benthic chambers and sediment core incubations, is slow, cumbersome, and often inaccurate. One promising new method for determining benthic fluxes is eddy correlation (EC), a minimally invasive, in situ technique based on high-speed velocity and concentration measurements. Widespread application of EC to a large range of chemicals of interest is currently limited, however, by the availability of rapid, high-resolution chemical sensors capable of precisely measuring concentrations at a point location and at sufficient speed (several Hz). A proof of concept spectrofluorometry instrument has been created that is capable of high-frequency concentration measurements of naturally fluorescent substances. Designed with the EC application in mind, the system utilizes optical fibers to transmit excitation and emission light, enabling in situ measurements at high spatial resolution. Emitted fluorescence light is passed through a tunable monochromator before reaching a photomultiplier tube; photons are quantified by a custom miniaturized, low-power photon counting circuit board. Preliminary results indicate that individual measurements made at 100 Hz of a 10 ppm humic acid solution were precise within 10%, thus yielding a precision of the order of +/- 1% in a second. Used in an EC system, this instrument will enable flux measurements of substances such as naturally occurring fluorescent dissolved organic material (FDOM). Measurement of fluxes of FDOM is significant in its own right, and also will allow the indirect measurement of the numerous other chemical fluxes that are associated with FDOM by using tracer techniques. The use of a tunable monochromator not only allows flexibility in detection wavelength, but also enables full wavelength scans of the emission spectrum, making the spectrofluorometer a dual-function device capable of both characterizing the

  3. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  4. Fast measurements of the electron temperature and parallel heat flux in ELMy H-mode on the COMPASS tokamak

    Science.gov (United States)

    Adamek, J.; Seidl, J.; Komm, M.; Weinzettl, V.; Panek, R.; Stöckel, J.; Hron, M.; Hacek, P.; Imrisek, M.; Vondracek, P.; Horacek, J.; Devitre, A.; the COMPASS Team

    2017-02-01

    We report the latest results on fast measurements of the electron temperature and parallel heat flux in the COMPASS tokamak scrape-off layer (SOL) and divertor region during ELMy H-mode plasmas. The system of ball-pen and Langmuir probes installed on the divertor target, the horizontal reciprocating manipulator and the fast data-acquisition system with sampling frequency rate f  =  5 MSa s-1 allow us to measure the electron temperature and parallel heat flux during inter-ELM and ELM periods with high temporal resolution. The filamentary structure of the electron temperature and parallel heat flux was observed during ELMs in the SOL as well as in the divertor region. The position of the filaments within ELMs is not regular and therefore the resulting conditionally averaged ELM neglects the peak values of the electron temperature and parallel heat flux. We have found a substantial difference between the value of the radial power decay length in the inter-ELM period λ q,inter  =  2.5 mm and the decay length of the peak ELM heat flux λ q,ELM  =  13.1 mm. The decay length of the ELM energy density was found to be λ E,ELM  =  5.4 mm.

  5. Reactivity of young chars via energetic distribution measurements. Final report, 1 September 1990--31 December 1994

    Energy Technology Data Exchange (ETDEWEB)

    Calo, J.M.; Zhang, L.; Lu, W.; Lilly, W.D.

    1996-01-01

    We have developed what we believe to be the very first, a priori, correlation/prediction technique for the gasification reactivity of coal char. With this method the gasification reactivity of a coal char as a function of temperature can be correlated using the data from a temperature programmed desorption (TPD) experiment following gasification under conditions where the reactivity is controlled by the thermal desorption of oxygen surface complexes formed during gasification. The current project was directed at extending and developing related techniques for the characterization and prediction/correlation of the reactivity of the ``young`` chars to CO{sub 2} and steam. Of particular interest was mapping of the reactivity behavior of the resultant chars, as revealed by the energetic heterogeneity of the complexes with char preparation conditions.

  6. Evaluation of a bedside monitor of regional CBF as a measure of CO2 reactivity in neurosurgical intensive care patients.

    Science.gov (United States)

    Soukup, Jens; Bramsiepe, Isa; Brucke, Matthias; Sanchin, Lhaghva; Menzel, Matthias

    2008-10-01

    Mild hyperventilation remains a key element in the management of elevated intracranial pressure. However, a harmful effect of hyperventilation on the development or deterioration of ischemic lesions has been shown in patients after severe head trauma. The objective of this study was to investigate the clinical feasibility and reliability of continuous monitoring of regional cerebral blood flow (rCBF) during mild hyperventilation using a thermodiffusion probe. CO2 reactivity was calculated. The measurement of the partial pressure of oxygen (PtiO2) in the cerebral tissue served as a reference parameter. An intraparenchymal intracranial pressure sensor, a multiparameter probe for determining the partial pressure of cerebral gases (pHti, PtiO2, PtiCO2), and a thermodiffusion probe for measuring rCBF were used in 10 intensive care patients. All patients were analgosedated and received pressure-controlled mechanical ventilation. Controlled mild hyperventilation was carried out on 2 consecutive days. CO2 reactivity was determined in relation to both CBF and PtiO2. Controlled hyperventilation resulted in a rCBF reduction from 30+/-3 mL/100 g/min to 25+/-2.4 mL/100 g/min (-17%; P<0.05) on the first day of examination and 31+/-3.6 mL/100 g/min to 22+/-4.9 mL/100 g/min (-29%; P<0.05) on the second day. Likewise, mild hyperventilation resulted in a reduction of regional cerebral tissue oxygen partial pressure from 20+/-2.9 mm Hg to 15+/-4 (-25%; P<0.05) on the first day and 20+/-3.1 mm Hg to 14+/-1.5 mm Hg (-30%; P<0.05) on the second. Continuous monitoring of regional CBF, using an intraparenchymally placed thermodiffusion probe, seems to be a simple and safe bedside technique. The promise of reliably monitoring and interpreting additional parameters such as PtiO2 and PtiCO2 warrants further investigation.

  7. New analysis procedure for fast and reliable size measurement of nanoparticles from atomic force microscopy images

    International Nuclear Information System (INIS)

    Boyd, Robert D.; Cuenat, Alexandre

    2011-01-01

    Accurate size measurement during nanoparticle production is essential for the continuing innovation, quality and safety of nano-enabled products. Size measurement by analysing a number of separate particles individually has particular advantages over ensemble methods. In the latter case nanoparticles have to be well dispersed in a fluid and changes that may occur during analysis, such as agglomeration and degradation, will not be detected which could lead to misleading results. Atomic force microscopy (AFM) allows imaging of particles both in air and liquid, however, the strong interactions between the probe and the particle will cause the broadening of the lateral dimension in the final image. In this paper a new procedure to measure the size of spherical nanoparticles from AFM images via vertical height measurement is described. This procedure will quickly analyse hundred of particles simultaneously and reproduce the measurements obtained from electron microscopy (EM). Nanoparticles samples that were difficult, if not impossible, to analyse with EM were successfully measured using this method. The combination of this procedure with the use of a metrological AFM moves closer to true traceable measurements of nanoparticle dispersions.

  8. Time-of-flight techniques applied to neutron spectra measurements in fast subcritical assemblies

    International Nuclear Information System (INIS)

    Rotival, Michel

    1975-04-01

    Time-of-flight measurements on Uranium-Graphite assemblies were performed using the BCMN linear accelerator. Methods to provide scalar spectra averaged over a core cell from these experimental results are described [fr

  9. Diode Laser-Based Sensor for Fast Measurement of Binary Gas Mixtures

    National Research Council Canada - National Science Library

    McNesby, Kevin

    1999-01-01

    The development and characterization of a gas sensor to measure binary mixtures of oxygen and the vapor from a series of volatile organic compounds, with a time resolution of 10 milliseconds, is described...

  10. Measurement of the thermal and fast neutron flux in a research reactor with a Li and Th loaded optical fibre detector

    CERN Document Server

    Yamane, Y; Misawa, T; Karlsson, J K H; Pázsit, I

    1999-01-01

    The spatial dependence of thermal and fast neutron flux was measured axially in the core of a 1 MW research reactor. The measurements were made by a thin optical fibre detector with a neutron sensitive ZnS(Ag) scintillation tip. For thermal neutrons sup 6 Li was used, whereas for fast neutrons sup 2 sup 3 sup 2 Th was used as neutron converter. The spatial dependence was measured by moving the fibre axially with a uniform speed. The measurement takes a few minutes, compared to up to 10 h with the conventional wire activation method. Comparison with traditional measurements shows a good agreement. (author)

  11. Multichannel heterodyne radiometers with fast-scanning backward-wave oscillators for ECE measurement on HT-7 tokamak

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Poznyak, V.I.; Ploskirev, G.; Kalupin, D.; Wan, Y.X.; Xie, J.K.; Luo, J.R.; Li, J.G.; Gao, X.; Wan, B.N.; Zhang, X.D.; Wang, K.J.; Kuang, G.L.

    2001-01-01

    Two sets of fast-scanning heterodyne radiometer receiver systems employing backward-wave oscillators (BWOs) in 78-118 and 118-178 GHz were developed and installed for electron cyclotron emission (ECE) measurements on HT-7 superconducting tokamak. The double sideband (DSB) radiometer in 78-118 GHz measures 16 ECE frequency points with a scanning time period of 0.65 ms. The other radiometer in 118-178 GHz consists of one independent channel of DSB heterodyne receiver with intermediate frequency (IF) of 100-500 MHz and two channels of single sideband (SSB) heterodyne receiver that are sensitive to upper sideband and lower sideband individually; the IF frequency of the SSB channels are 1.5 GHz around the local oscillator frequencies with 1 GHz bandwidth. By employing a novel design, this unique radiometer measures 3 ECE frequency points at each of the 16 local oscillator frequency points in 118-178 GHz, and the full band can be swept in 0.65 ms period, thus the radiometer measures 48 ECE frequency points in 0.65 ms in principle. Each of the local oscillators' frequency points can be preset by program to meet specific physics interests. Horizontal view of ECE was installed to measure electron temperature profiles; vertically viewing optics along a perpendicular chord was also installed to study nonthermal ECE spectra. Preliminary measurement results were presented during ohmic and pellet injection plasmas

  12. Measuring the cosmic ray muon-induced fast neutron spectrum by (n,p) isotope production reactions in underground detectors

    International Nuclear Information System (INIS)

    Galbiati, Cristiano; Beacom, John F.

    2005-01-01

    While cosmic ray muons themselves are relatively easy to veto in underground detectors, their interactions with nuclei create more insidious backgrounds via (i) the decays of long-lived isotopes produced by muon-induced spallation reactions inside the detector (ii) spallation reactions initiated by fast muon-induced neutrons entering from outside the detector, and (iii) nuclear recoils initiated by fast muon-induced neutrons entering from outside the detector. These backgrounds, which are difficult to veto or shield against; are very important for solar, reactor, dark matter, and other underground experiments, especially as increased sensitivity is pursued. We used FLUKA to calculate the production rates and spectra of all prominent secondaries produced by cosmic ray muons, in particular focusing on secondary neutrons, because of their importance. Since the neutron spectrum is steeply falling, the total neutron production rate is sensitive to just the relatively soft neutrons and not the fast-neutron component. We show that the neutron spectrum in the range ∼10-100 MeV can instead be probed by the (n,p)-induced isotope production rates 12 C(n,p) 12 B and 16 O(n,p) 16 N in oil- and water-based detectors. The result for 12 B is in good agreement with the recent KamLAND measurement. Besides testing the calculation of muon secondaries, these results are also of practical importance, since 12 B (T 1/2 =20.2 ms, Q=13.4 MeV) and 16 N (T 1/2 =7.13 s, Q=10.4 MeV) are among the dominant spallation backgrounds in these detectors

  13. Reactive oxygen species measurement in neat and washed semen: comparative analysis and its significance in male infertility assessment.

    Science.gov (United States)

    Venkatesh, S; Shamsi, M B; Dudeja, S; Kumar, R; Dada, Rima

    2011-01-01

    Oxidative stress (OS) is a major concern in idiopathic male infertility as elevated levels of reactive oxygen species (ROS) in the semen is believed to adversely affect sperm functional competence and damage both nuclear and mitochondrial DNA. Therefore, identifying infertile men with seminal OS may be used as a valuable tool in the assessment of male infertility. Semen is a complex mixture of spermatozoa and seminal plasma which is rich in enzymatic and non-enzymatic antioxidants. However, the measurement of ROS in the semen and its application in male infertility assessment is poorly understood. The aim of the present study was to compare the significance of ROS measurement in washed and neat semen. The study included 65 infertile men with abnormal semen (SA) parameters, 17 infertile men with normal semen (NS) parameters and 43 fertile controls (FC). ROS levels in both washed and neat semen were measured by luminol-dependent chemiluminescence assay and the values were expressed as 10(4 )RLU per minute per 20 million spermatozoa. The levels of ROS in both washed and neat semen were found to be significantly higher (P neat semen 0.03, washed semen 0.24), whereas infertile men with SA group had the highest median ROS level (neat semen 3.44, washed semen 27.42). In all subjects, ROS levels were found to be higher in washed semen than in neat semen. A strong positive correlation (r = 0.847, P neat and washed semen was observed. Measurement of ROS in neat semen reflects the original oxidative status in the actual sperm microenvironment and is an easy, simple, inexpensive and rapid method compared with ROS measurement from washed semen. ROS measurement in washed semen is done to assess ROS levels following sperm processing as in cases opting for assisted conception. As both ROS values in neat and washed show a positive correlation, neat semen may be used as a valuable tool for identifying infertile men with seminal OS. ROS levels are elevated in nearly 70% men with

  14. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  15. Fast and Accurate Measurement of Entropy Profiles of Commercial Lithium-Ion Cells

    International Nuclear Information System (INIS)

    Osswald, Patrick J.; Rosario, Manuel del; Garche, Jürgen; Jossen, Andreas; Hoster, Harry E.

    2015-01-01

    We report on an effective approach to speed up the measurement of thermodynamic characterization curves (entropy of reaction Δ r S(x)) of rechargeable batteries, in particular commercial 18650 lithium ion cells. We propose and demonstrate a measurement and data processing protocol that reduces the time required to record entropy profiles from time scales of weeks to time scales of hours – without loss in accuracy. For time consuming studies such as investigations on ageing of battery cells, entropy profile measurements thus become as feasible as conventional electrochemical characterisation techniques like dV/dQ or cyclic voltammetry. We demonstrate this at the examples of two ageing protocols applied to a commercial high power and a commercial high energy cell, respectively: (i) accelerated calendric aging by storing cells at 100% state of charge at 60 °C and (ii) continuous cycling with a 1C current at 25 °C

  16. Measurements of fast neutron-induced fission data of Np-237

    Energy Technology Data Exchange (ETDEWEB)

    Win, Than; Saito, Keiichiro; Baba, Mamoru; Iwasaki, Tomohiko; Ibaraki, Masanobu; Miura, Takako; Sanami, Toshiya; Nauchi, Yasushi; Hirakawa, Naohiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1998-03-01

    We have performed the following measurements for {sup 237}Np using the 4.5 MV Dynamitron accelerator of Tohoku University as the pulsed neutron source: (1) Prompt fission neutron spectrum for 0.62 MeV incident neutrons, and (2) Neutron-Induced fission cross-section between 10 and 100 keV. The prompt fission neutron spectrum was measured using TOF method with a heavily shielded NE213 scintillation detector. The Maxwellian temperature T{sub m} derived is 1.28 MeV, which is lower than that of 1.38 MeV in JENDL-3.2. The fission cross sections were measured between 10 - 100 keV. The results are between JENDL-3.2 and ENDF/B-VI. (author)

  17. Computer-Mediated Communication Preferences and Individual Differences in Neurocognitive Measures of Emotional Attention Capture, Reactivity and Regulation

    Science.gov (United States)

    Babkirk, Sarah; Luehring-Jones, Peter; Dennis, Tracy A.

    2016-01-01

    The use of computer-mediated communication (CMC) to engage socially has become increasingly prevalent, yet few studies examined individual differences that may shed light on implications of CMC for adjustment. The current study examined neurocognitive individual differences associated with preferences to use technology in relation to social-emotional outcomes. In Study 1 (N =91), a self-report measure, the Social Media Communication Questionnaire (SMCQ), was evaluated as an assessment of preferences for communicating positive and negative emotions on a scale ranging from purely via CMC to purely face-to-face. In Study 2, SMCQ preferences were examined in relation to event-related potentials (ERPs) associated with early emotional attention capture and reactivity (the frontal N1) and later sustained emotional processing and regulation [the late positive potential (LPP)]. Electroencephalography (EEG) was recorded while 22 participants passively viewed emotional and neutral pictures and completed an emotion regulation task with instructions to increase, decrease or maintain their emotional responses. A greater preference for CMC was associated with reduced size of and satisfaction with social support, greater early (N1) attention capture by emotional stimuli, and reduced LPP amplitudes to unpleasant stimuli in the increase emotion regulatory task. These findings are discussed in the context of possible emotion- and social-regulatory functions of CMC. PMID:26613269

  18. An automated analyzer to measure surface-atmosphere exchange fluxes of water soluble inorganic aerosol compounds and reactive trace gases.

    Science.gov (United States)

    Thomas, Rick M; Trebs, Ivonne; Otjes, René; Jongejan, Piet A C; Ten Brink, Harry; Phillips, Gavin; Kortner, Michael; Meixner, Franz X; Nemitz, Eiko

    2009-03-01

    Here, we present a new automated instrument for semicontinuous gradient measurements of water-soluble reactive trace gas species (NH3, HNO3, HONO, HCl, and SO2) and their related aerosol compounds (NH4+, NO3-, Cl-, SO4(2-)). Gas and aerosol samples are collected simultaneously at two heights using rotating wet-annular denuders and steam-jet aerosol collectors, respectively. Online (real-time) analysis using ion chromatography (IC) for anions and flow injection analysis (FIA) for NH4+ and NH3 provide a half-hourly averaged gas and aerosol gradients within each hour. Through the use of syringe pumps, IC preconcentration columns, and high-quality purified water, the system achieves detection limits (3sigma-definition) under field conditions of typically: 136/207,135/114, 29/ 22,119/92, and 189/159 ng m(-3) for NH3/NH4+, HNO3/NO3-, HONO/ NO2-, HCl/Cl- and SO2/SO4(2-), respectively. The instrument demonstrates very good linearity and accuracy for liquid and selected gas phase calibrations over typical ambient concentration ranges. As shown by examples from field experiments, the instrument provides sufficient precision (3-9%), even at low ambient concentrations, to resolve vertical gradients and calculate surface-atmosphere exchange fluxes undertypical meteorological conditions of the atmospheric surface layer using the aerodynamic gradient technique.

  19. A fast algorithm for robust mixtures in the presence of measurement errors.

    Science.gov (United States)

    Sun, Jianyong; Kaban, Ata

    2010-08-01

    In experimental and observational sciences, detecting atypical, peculiar data from large sets of measurements has the potential of highlighting candidates of interesting new types of objects that deserve more detailed domain-specific followup study. However, measurement data is nearly never free of measurement errors. These errors can generate false outliers that are not truly interesting. Although many approaches exist for finding outliers, they have no means to tell to what extent the peculiarity is not simply due to measurement errors. To address this issue, we have developed a model-based approach to infer genuine outliers from multivariate data sets when measurement error information is available. This is based on a probabilistic mixture of hierarchical density models, in which parameter estimation is made feasible by a tree-structured variational expectation-maximization algorithm. Here, we further develop an algorithmic enhancement to address the scalability of this approach, in order to make it applicable to large data sets, via a K-dimensional-tree based partitioning of the variational posterior assignments. This creates a non-trivial tradeoff between a more detailed noise model to enhance the detection accuracy, and the coarsened posterior representation to obtain computational speedup. Hence, we conduct extensive experimental validation to study the accuracy/speed tradeoffs achievable in a variety of data conditions. We find that, at low-to-moderate error levels, a speedup factor that is at least linear in the number of data points can be achieved without significantly sacrificing the detection accuracy. The benefits of including measurement error information into the modeling is evident in all situations, and the gain roughly recovers the loss incurred by the speedup procedure in large error conditions. We analyze and discuss in detail the characteristics of our algorithm based on results obtained on appropriately designed synthetic data experiments

  20. In pile measurement of creep rate of stainless steel cladding tubes for fast reactor pins

    International Nuclear Information System (INIS)

    Calza Bini, A.; Cosoli, G.; Filacchioni, G.; Lanchi, M.; Nobili, A.; Pesce, E.; Rocca, U.V.; Rotoloni, P.L.

    1975-01-01

    Results are reported of a direct in pile measurement of creep on a cladding sample of 10cm length, under tensile stress of 22.82kg/mm 2 at a temperature of 550 0 during about 500 hours, up to an integrated flux of 2.6.10 20 n/cm 2 . Two identical samples were irradiated in the same temperature and flux conditions to be submitted to out of pile creep measurements together with other unirradiated samples. The aim of this first experiment was mainly to set up the device and to evaluate the kind and the quality of the available data

  1. Fast and accurate enzyme activity measurements using a chip-based microfluidic calorimeter.

    Science.gov (United States)

    van Schie, Morten M C H; Ebrahimi, Kourosh Honarmand; Hagen, Wilfred R; Hagedoorn, Peter-Leon

    2018-03-01

    Recent developments in microfluidic and nanofluidic technologies have resulted in development of new chip-based microfluidic calorimeters with potential use in different fields. One application would be the accurate high-throughput measurement of enzyme activity. Calorimetry is a generic way to measure activity of enzymes, but unlike conventional calorimeters, chip-based calorimeters can be easily automated and implemented in high-throughput screening platforms. However, application of chip-based microfluidic calorimeters to measure enzyme activity has been limited due to problems associated with miniaturization such as incomplete mixing and a decrease in volumetric heat generated. To address these problems we introduced a calibration method and devised a convenient protocol for using a chip-based microfluidic calorimeter. Using the new calibration method, the progress curve of alkaline phosphatase, which has product inhibition for phosphate, measured by the calorimeter was the same as that recorded by UV-visible spectroscopy. Our results may enable use of current chip-based microfluidic calorimeters in a simple manner as a tool for high-throughput screening of enzyme activity with potential applications in drug discovery and enzyme engineering. Copyright © 2017. Published by Elsevier Inc.

  2. Fast wake measurements with LiDAR at Risø test field

    DEFF Research Database (Denmark)

    Bingöl, Ferhat; Trujillo, J.J.; Mann, Jakob

    2008-01-01

    The vast majority of wind turbines are today erected in wind farms. As a consequence, wake generated loads are becoming more and more important. We present a new and successful experimental technique, based on remote sensing, to measure instantaneously the flow in the wake of wind turbines. Downs...

  3. Definitions and Approaches to Measuring Reading Proficiency. CEELO FastFact

    Science.gov (United States)

    Connors-Tadros, Lori

    2014-01-01

    A state contacted the Center on Enhancing Early Learning Outcomes (CEELO) for guidance in developing a definition of "reading proficiency" and what it means to "read on grade level by third grade." The state also requested information on how national sources or states define and measure proficiency. The state was particularly…

  4. Utility of measuring serum levels of anti-PGL-I antibody, neopterin and C-reactive protein in monitoring leprosy patients during multi-drug treatment and reactions

    NARCIS (Netherlands)

    Silva, E. A.; Iyer, A.; Ura, S.; Lauris, J. R.; Naafs, B.; Das, P. K.; Vilani-Moreno, F.

    2007-01-01

    To verify the validity of measuring the levels of Mycobacterium leprae-specific anti-phenolic glycolipid (PGL)-I antibody, neopterin, a product of activated macrophages, and C-reactive protein (CRP), an acute phase protein, in serial serum samples from patients for monitoring the leprosy spectrum

  5. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25-...Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...

  6. Kinetic studies on a repetitively pulsed fast reactor

    International Nuclear Information System (INIS)

    Das, S.

    1982-01-01

    Neutronic analysis of an earlier proposed periodically pulsed fast reactor at Kalpakkam (KPFR) has been carried out numerically under equilibrium and transient conditions using the one-point model of reactor kinetics and the experimentally measured total worth of reactivity modulator, the parabolic coefficient of reactivity of the movable reflector and the mean prompt neutron lifetime. Results of steady-state calculations - treated on the basis of delayed neutron precursor and energy balances during a period of operation - have been compared with the analytical formulae of Larrimore for a parabolic reactivity input. Empirical relations for half-width of the fast neutron pulse, the peak pulse power and the power at first crossing of prompt criticality have been obtained and shown to be accurate enough for predicting steady-state power pulse characteristics of a periodically pulsed fast reactor. The concept of a subprompt-critical reactor has been used to calculate the fictitious delayed neutron fraction, β of the KPFR through a numerical experiment. Relative pulse height stability and pulse shape sensitivity to changes of maximum reactivity is discussed. With the aid of new safety concepts, the Power Amplification Factor (PAF) and the Pulse Growth Factor (Rsub(p)), the dynamics KPFR under accidental conditions has been studied for step and ramp reactivity perturbations. All the analysis has been done without taking account of reactivity feedback. (orig.)

  7. Use of fast scopes to enable Thomson scattering measurement in presence of fluctuating plasma light

    International Nuclear Information System (INIS)

    McLean, H.S.; Moller, J.; Hill, D.N.

    2004-01-01

    The addition of inexpensive high-speed oscilloscopes has enabled higher T e Thomson scattering measurements on the Sustained Spheromak Physics Experiment. Along with signal correlation techniques, the scopes allow analyses based on the shape of the scattered laser pulse to discriminate against fluctuating background plasma light that often make gated-integrator measurements unreliable. A 1.4 J Nd:YAG laser at 1064 nm is the scattering source. Spatial locations are coupled by viewing optics and fibers to four-wavelength-channel filter polychrometers. Ratios between the channels determine T e while summations of the channels determine density. Typically, the channel that provides a scattered signal at higher T e is contaminated by fluctuating background light. Individual channels are correlated with either a modeled representation of the laser pulse or a noise-free scattered laser light signal to extract channel amplitudes

  8. A simple, low cost and fast improved fluorimetric method for Histamine measurement

    Directory of Open Access Journals (Sweden)

    Poorpak Z

    2001-11-01

    Full Text Available The well-known fluorimetric method for histamine measurement which is one of the common methods in diagnostic laboratories was modified to accelerate and facilitate measurement of serum histamine levels and decrease the costs and restrictions. The modified method needs only 1 ml of whole blood (or serum instead of about 10 ml in original method which is difficult almost or impossible specially for children. In addition, very small amounts of the expensive materials are needed and the samples are saved for about 15 days in -20°C which makes no significant changes. Because in most cases, sample can not be read at sampling day, the saving possibility is an advantage for improved method.

  9. Measurements of actinide transmutation in the hard spectrum of a fast reactor

    International Nuclear Information System (INIS)

    Trybus, C.L.; Collins, P.J.; Maddison, D.W.; Bunde, K.A.; Pallmtag, S.; Palmiotti, G.

    1994-01-01

    Measurements of fission and capture in 235 U, 238 U, 239 Pu and 237 Np and in their product actinides have been made following irradiation in the metal-fuel core of EBR-II. The reactor has a peak flux around 500keV and the data complement measurements in the softer spectrum of an LMFBR. Irradiations were made at the same time for a set of standard dosimeter samples. These provide a test of calculated spectra and are also used for validation of steel activations and calculated atomic displacement rates. Calculation were made with modem transport codes using ENDF/B-5.2 data. Comparisons are made, using a simple homogeneous model, producing a similar spectrum, using ENDF/B-6.2 and JEFF-2 data

  10. Fast, versatile x-ray fluorescence method for measuring tin in impregnated wood

    DEFF Research Database (Denmark)

    Drabæk, I.; Christensen, Leif Højslet

    1985-01-01

    The present paper describes an energy-dispersive x-ray fluorescence method for measuring tin in bis(tri-n-butyl)tin-oxide impregnated wood. The proposed method is of the backscatter/fundamental parameter type. Its versatility, precision, and accuracy is demonstrated by analyses of eleven samples...... of sapwood of Baltic Redwood. The results obtained are compared with those from neutron activation analysis....

  11. A fast radiochemical procedure to measure Tc-99 in environmental samples and gaseous and liquid effluents

    International Nuclear Information System (INIS)

    Luxenburger, H.J.; Schuettelkopf, H.; Bohn, B.

    1984-08-01

    Liquid effluent samples are collected in polyethylene bottles. Sampling in the gaseous effluents relies on conventional NaOH scrubbers. No noticeable adsorption on the vessel walls takes place in HNO 3 /H 2 O 2 and NaOH, respectively, in the plastic botteles used. A known amount of Tc-95m is added in order to determine the chemical yield prior to the analysis. The pertechnetate in the samples is first fixed on an anionexchanger. Following elution with perchlorate/sulfite solution TC is coprecipitated with iron(II) hydroxide. Having dissolved the precipitation in H 2 O 2 /H 2 SO 4 one extracts with TBP/alkane. To achieve a better decontamination from other nuclides a re-extraction is performed with NaOH and after acidification with H 2 SO 4 a further extraction using TBP/Alkane. Before the measurement of the sample the alkane is eliminated in a rotation evaporator and the remaining TBP is dissolved directly in the liquid scintillator. Other beta emitters generated as fission products in the course of nuclear fission are satisfactorily separated during the analysis. The decontamination factors for I, Se, Te, Sb, and Ru are > 10 5 . The measurements are carried out with a Beckman LS 7800 instrument. The optimum channel setting is found from the spectra of the two nuclides Tc-95m and Tc-99. The quenching plots are determined accordingly. The measurements are evaluated with a table computer. Chemical yields of 50-90% are achieved. The detection limit for 600 minutes of measuring time is 1 pCi per sample. One person is capable of performing about 15 analyses per week using the method described. (orig./HP) [de

  12. TLD gamma-ray energy deposition measurements in the zero energy fast reactor ZEBRA

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1977-01-01

    A recent study of gamma-ray energy deposition was carried out in the Zebra reactor at AEE Winfrith during a collaborative programme between the UKAEA and PNC of Japan. The programme was given the title MOZART. This paper describes the TLD experiments in the MOZART MZB assembly and discusses the technique and various corrections necessary to relate the measured quantity to the calculated energy deposition

  13. A technique for fast and accurate measurement of hand volumes using Archimedes' principle.

    Science.gov (United States)

    Hughes, S; Lau, J

    2008-03-01

    A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494 +/- 6 ml and 312 +/- 7 ml for the immersion method and 476 +/- 14 ml and 302 +/- 8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.

  14. A fast spectroscopic diagnostic for the measurement of plasma impurity ion dynamics

    International Nuclear Information System (INIS)

    Den Hartog, D.J.; Fonck, R.J.

    1994-04-01

    A high-resolution spectrometer has been developed and used to measure simultaneously impurity ion temperature and flow velocities in high temperature plasmas with 10 μs temporal resolution (limited by digitization rate). This device is actually a duo-spectrometer: measurements from two different chordal views of the plasma can be made simultaneously via two separate quartz input fiber optic bundles coupled to the entrance slits which are tilted to compensate for line curvature. The dispersed spectra on the exit plane of the duo-spectrometer are coupled via quartz fiber optics to two arrays of 16 photomultiplier tubes each. Measurement made by recording the Doppler broadened and shifted 227.091 nm emission from the CV impurity ions in the MST reversed-field pinch (RFP) plasma have achieved precisions of <6 eV for temperatures of 150 Ev and <0.7 km/s for flow velocities of 6 km/s. Representative results from the MsT RFP indicate that the toroidal flow velocity drops and ion temperature increases during saw tooth events in MST

  15. Measurement of time-dependent fast neutron energy spectra in a depleted uranium assembly

    International Nuclear Information System (INIS)

    Whittlestone, S.

    1980-10-01

    Time-dependent neutron energy spectra in the range 0.6 to 6.4 MeV have been measured in a depleted uranium assembly. By selecting windows in the time range 0.9 to 82 ns after the beam pulse, it was possible to observe the change of the neutron energy distributions from spectra of predominantly 4 to 6 MeV neutrons to spectra composed almost entirely of fission neutrons. The measured spectra were compared to a Monte Carlo calculation of the experiment using the ENDF/B-IV data file. At times and energies at which the calculation predicted a fission spectrum, the experiment agreed with the calculation, confirming the accuracy of the neutron spectroscopy system. However, the presence of discrepancies at other times and energies suggested that there are significant inconsistencies in the inelastic cross sections in the 1 to 6 MeV range. The time response generated concurrently with the energy spectra was compared to the Monte Carlo calculation. From this comparison, and from examination of time spectra measured by other workers using 235 U and 237 Np fission detectors, it would appear that there are discrepancies in the ENDF/B-IV cross sections below 1 MeV. The predicted decay rates were too low below and too high above 0.8 MeV

  16. Stripline fast faraday cup for measuring GHz structure of ion beams

    International Nuclear Information System (INIS)

    Bogaty, J.M.

    1992-01-01

    This patent describes an apparatus for measuring the structure on ion beams. It comprises a dielectric strip with an opening therethrough to create an air gap from one side of the dielectric strip to the other; a conductive stripeline bonded to one side of the dielectric strip and a groundplane bonded to the opposing side of the dielectric strip wherein the airgap remains open; a thin dielectric film coating the groundplane; a second groundplane adhering to the thin dielectric film wherein a portion of the thin dielectric film adjacent to the air gap is exposed; a fine mesh electrostatic screen bonded to the second groundplane directly over the air gap; means for matching the impedance at the electrostatic screen with that of the stripline; a Faraday cup mounted opposite the electrostatic screen with a drift space between the electrostatic screen and the Faraday cup; means for reducing RF reflections from the stripline through the use of a terminating impedance; means for biasing the electrostatic screen; means for outputting information to an amplifier; and a measuring device coupled to the amplifier where the measuring device receives information from the amplifier

  17. Interferometer for Measuring Fast Changes of Refractive Index and Temperature in Transparent Liquids

    DEFF Research Database (Denmark)

    Miller, Arne; Hussmann, E. K.; McLaughlin, W. L.

    1975-01-01

    A double‐beam interferometer has been designed for detecting changes of refractive index in transparent liquids associated with the absorption of ionizing radiation energy, due to short electron beam pulses from an accelerator. The response time of the interferometer is less than 0.2 μsec......, and refractive index changes of the order of 10−7 can be measured, corresponding to a temperature change of ∼10−3  °C and an absorbed dose in water of ∼350 rad. The interferometer can be used as either a real‐time or integrating radiation dosimeter, if the temperature coefficient of the refractive index (dn...

  18. Design of a Fast Measuring System for the Section Size of Automobile Rubber Hose Withhold Parts

    Science.gov (United States)

    Meng, Fanwu; Zhang, Teng; Ren, Jingrui

    2017-12-01

    The quality of withhold parts determines the service life of high-pressure rubber hose to a great extent. Leakage at withholding is the main form of high pressure hose failure in the several forms. The quickest and most effective method to detect the withholding quality is measuring the section size of the withhold parts. As long as the section size is in line with the provisions, that is, the quality of hose withholding is qualified. In this paper, the mesurement system which is designed improves low efficiency of manual mesurement.

  19. Fast sensitive amplifier for two-probe conductance measurements in single molecule break junctions

    Science.gov (United States)

    Johnson, Tyler K.; Ivie, Jeffrey A.; Jaruvang, Jason; Monti, Oliver L. A.

    2017-03-01

    We demonstrate an amplifier based on the Wheatstone bridge designed specifically for use in single molecule break junctions. This amplifier exhibits superior performance due to its large bandwidth, flat frequency response, and high sensitivity. The amplifier is capable of measuring conductance values from 102 to 10-6G0 (G0 = 2e2/h), while maintaining a bandwidth in excess of 20 kHz, and shows remarkable resolution in the molecular conductance regime of 10-2 to 10-5 G0.

  20. Manipulation of Samples at Extreme Temperatures for Fast in-situ Synchrotron Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Richard [Materials Development, Inc., Arlington Heights, IL (United States)

    2016-04-22

    An aerodynamic sample levitation system with laser beam heating was integrated with the APS beamlines 6 ID-D, 11 ID-C and 20 BM-B. The new capability enables in-situ measurements of structure and XANES at extreme temperatures (300-3500 °C) and in conditions that completely avoid contact with container surfaces. In addition to maintaining a high degree of sample purity, the use of aerodynamic levitation enables deep supercooling and greatly enhanced glass formation from a wide variety of melts and liquids. Development and integration of controlled extreme sample environments and new measurement techniques is an important aspect of beamline operations and user support. Processing and solidifying liquids is a critical value-adding step in manufacturing semiconductors, optical materials, metals and in the operation of many energy conversion devices. Understanding structural evolution is of fundamental importance in condensed materials, geology, and biology. The new capability provides unique possibilities for materials research and helps to develop and maintain a competitive materials manufacturing and energy utilization industry. Test samples were used to demonstrate key features of the capability including experiments on hot crystalline materials, liquids at temperatures from about 500 to 3500 °C. The use of controlled atmospheres using redox gas mixtures enabled in-situ changes in the oxidation states of cations in melts. Significant innovations in this work were: (i) Use of redox gas mixtures to adjust the oxidation state of cations in-situ (ii) Operation with a fully enclosed system suitable for work with nuclear fuel materials (iii) Making high quality high energy in-situ x-ray diffraction measurements (iv) Making high quality in-situ XANES measurements (v) Publishing high impact results (vi) Developing independent funding for the research on nuclear materials This SBIR project work led to a commercial instrument product for the niche market of processing and

  1. Eddy Covariance Measurements of Methane Flux at Remote Sites with New Low-Power Lightweight Fast Gas Analyzer

    Science.gov (United States)

    Xu, Liukang; Burba, George; Schedlbauer, Jessica; Zona, Donatella; McDermitt, Dayle K.; Anderson, Tyler; Oberbauer, Steven; Oechel, Walter; Komissarov, Anatoly; Riensche, Brad

    2010-05-01

    Majority of natural methane production happens at remote unpopulated areas in ecosystems with little or no infrastructure or easily available grid power, such as arctic and boreal wetlands, tropical mangroves, etc. Present approaches for direct measurements of CH4 fluxes rely on fast closed-path analyzers, which have to work under significantly reduced pressures, and require powerful pumps and grid power. Power and labor demands may be reasons why CH4 flux is often measured at locations with good infrastructure and grid power, and not with high CH4 production. An instrument was developed to allow Eddy Covariance measurements of CH4 flux with power consumption 30-150 times below presently available technologies. This instrument, LI-7700, uses good frequency response and undisturbed in-situ sampling. It enables long-term deployment of permanent, portable or mobile CH4 flux stations at remote locations with high CH4 production, because it can be powered by a solar panels or a small generator. Authors appreciate help and support provided by the LI-COR Engineering Team, Barrow Arctic Science Consortium (BASC), and numerous colleagues involved in measurements, logistics, and maintenance of the experimental field sites. This project was supported by the Small Business Innovation Research (SBIR) and Small Business Technology Transfer Program (STTR) program of the Department of Energy (DOE), Grant Number DE-FG02-05ER84283.

  2. Measurement of fast neutron induced fission cross section ratios of Pu-240 and Pu-242 relative to U-235

    International Nuclear Information System (INIS)

    Iwasaki, Tomohiko; Manabe, Fumitoshi; Baba, Mamoru; Matsuyama, Shigeo; Kimiyama, Hiroyuki; Hirakawa, Naohiro

    1990-01-01

    Fission cross section ratios of 240 Pu and 242 Pu relative to 235 U were measured by using the 4.5 MV Dynamitron accelerator of Tohoku University. The measurement using mono-energetic neutrons was performed in the neutron energy range of 0.6∼7 MeV with the time-of-flight method. Prior to the measurement, a fast timing back-to-back fission chamber was developed with good time resolution to reduce the backgrounds due to α-particles and spontaneous fissions. Furthermore, we took account of the effect of the nonuniformity of fission sample thickness for accurate determination of fission cross section ratio. The uncertainty was estimated by analyzing the correlation between the error sources. The correlation matrix between the measured data was given. The overall uncertainty of the present results is about 2%. For both nuclides, the present results agree well with those by Meadows and by Kuprijanov et al. The JENDL-3 evaluation generally has good agreement with the present results. However, the evaluated data are slightly higher around 1 MeV and lower above 6 MeV than the present results. (author)

  3. Three-dimensional trace measurements for fast-moving objects using binary-encoded fringe projection techniques.

    Science.gov (United States)

    Su, Wei-Hung; Kuo, Cho-Yo; Kao, Fu-Jen

    2014-08-20

    A fringe projection technique to trace the shape of a fast-moving object is proposed. A binary-encoded fringe pattern is illuminated by a strobe lamp and then projected onto the moving object at a sequence of time. Phases of the projected fringes obtained from the sequent measurements are extracted by the Fourier transform method. Unwrapping is then performed with reference to the binary-encoded fringe pattern. Even though the inspected object is colorful, fringe orders can be identified. A stream of profiles is therefore retrieved from the sequent unwrapped phases. This makes it possible to analyze physical properties of the dynamic objects. Advantages of the binary-encoded fringe pattern for phase unwrapping also include (1) reliable performance for colorful objects, spatially isolated objects, and surfaces with large depth discontinuities; (2) unwrapped errors only confined in a local area; and (3) low computation cost.

  4. The relationship between HbA(1c) and fasting plasma glucose in patients with increased plasma liver enzyme measurements

    DEFF Research Database (Denmark)

    Christiansen, R; Rasmussen, L Melholt; Nybo, H

    2012-01-01

    Background:  HbA(1c) is currently being introduced for diagnostic purpose in diabetes. Previous studies have, however, indicated that patients with liver disease have false low HbA(1c) levels. We therefore investigated the correlation between HbA(1c) and plasma glucose in patients with different...... levels of increased liver enzyme concentrations. Methods:  Data from 10 065 patients with simultaneous measurement of HbA(1c) , venous fasting plasma glucose, alanine aminotransferase and γ-glutamyl transferase were extracted from our laboratory database. Correlations were investigated in four patient...... groups divided according to their liver enzyme concentrations. Results:  The correlation between HbA(1c) and plasma glucose was high in all groups, with r = 0.77 for men and r = 0.78 for women (P ...

  5. Measurements of the MHD activity and of the micro-turbulence using fast sweep reflectometry

    International Nuclear Information System (INIS)

    Vermare, L.

    2005-04-01

    This work is dedicated to the measurement of the fluctuations of the electronic density of a fusion plasma through the use of sweep reflectometry. In a plasma 2 types of fluctuations can be characterized: on one hand the plasma fluctuations over a large spatial scale (> 1 cm), they are associated with MHD-type modes and on the other hand the micro-fluctuations (< 1 cm) associated with micro-turbulence. The first chapter presents the issue of confinement in tokamak plasmas. In the chapter 2, the technical specificities of the reflectometers used in this work are detailed as well as the wave propagation laws in turbulent plasmas. In the chapter 3 the author shows how the sweep reflectometry can detect rational surfaces on which magnetic islands develop. The chapter 4 deals with the measurement of micro-turbulence in mode-X plasmas. A method giving the determination of the local spectra in radial wave numbers of the density fluctuations is proposed. The knowledge of these spectra gives the distribution of the turbulence energy over various spatial scales and could help to identify the types of micro-instabilities present in the plasma. (A.C.)

  6. A Fast Method for Measuring Psychophysical Thresholds Across the Cochlear Implant Array

    Directory of Open Access Journals (Sweden)

    Julie A. Bierer

    2015-02-01

    Full Text Available A rapid threshold measurement procedure, based on Bekesy tracking, is proposed and evaluated for use with cochlear implants (CIs. Fifteen postlingually deafened adult CI users participated. Absolute thresholds for 200-ms trains of biphasic pulses were measured using the new tracking procedure and were compared with thresholds obtained with a traditional forced-choice adaptive procedure under both monopolar and quadrupolar stimulation. Virtual spectral sweeps across the electrode array were implemented in the tracking procedure via current steering, which divides the current between two adjacent electrodes and varies the proportion of current directed to each electrode. Overall, no systematic differences were found between threshold estimates with the new channel sweep procedure and estimates using the adaptive forced-choice procedure. Test–retest reliability for the thresholds from the sweep procedure was somewhat poorer than for thresholds from the forced-choice procedure. However, the new method was about 4 times faster for the same number of repetitions. Overall the reliability and speed of the new tracking procedure provides it with the potential to estimate thresholds in a clinical setting. Rapid methods for estimating thresholds could be of particular clinical importance in combination with focused stimulation techniques that result in larger threshold variations between electrodes.

  7. A compact fast ionization gauge for in situ measurement of high-density neutral flow dynamics

    Science.gov (United States)

    Weber, T. E.; Intrator, T. P.

    2014-04-01

    A compact ionization gauge has been developed to carry out in situ measurements of high density (1020-1022 m-3) neutral gas flow dynamics with high temporal and spatial resolution. Key design aspects are discussed including gauge sensitivity and time response scaling with decreased probe dimensions, high-pressure operation, improved driver circuit bandwidth, and techniques for constructing a miniaturized probe head. Gas adsorption was discovered to significantly alter emission current and gauge sensitivity over timescales of several seconds. This effect must be taken into consideration when making time-resolved, high-density measurements. Over short timescales gauge response was predicted by scaling the sensitivity of a nominal Bayard-Alpert gauge to account for variations in probe dimensions and species-dependent ionization cross-section. Time-resolved neutral density profiles have been acquired in the Magnetized Shock Experiment at Los Alamos National Laboratory, providing data on the initial conditions of the ionization, plasmoid formation, and translation processes. It is shown that the desired density profiles can be achieved using a dynamic gas fill and that density can be scaled independently of the spatial profile.

  8. Peculiarities of increasing the fast response of a measuring apparatus for the instrumental activation analysis

    International Nuclear Information System (INIS)

    Bovin, V.P.; Eldashev, V.V.; Kandaurov, V.A.; Malinovskij, V.N.; Tustanovskij, V.T.

    1977-01-01

    The flowsheet of measuring channel of apparatus for activation analysis is presented. The main methods of error correction when operating with high pulse loadings are discussed. The measuring channel contains following functional units: detection unit, shaper-preamplifier, basic amplifier, analog-to-digital converter, memory and arithmetic units. To stabilize detection unit parameters it is offered to use autostabilization circuit with differential selectors and discrete relay-type converters. To exclude superimposed pulses rejectors are used. The enhancement of the counting rate causes unfortunately a partly data loss. To diminish this unfavourable effect a timer is introduced into the spectrometric channel enabling to determine the ''live'' time and to correct the pulse count with account for pulse superimposition. A comparative analysis of various types of analog-to-gigital converters is carried out. A flowsheet of scintillation spectrometric channel is presented consisting of units in the ''Vector'' standard which make it possible to operate with counting rates up to 10 5 pulse/s with the error <=1%

  9. Intercomparison of fast response commercial gas analysers for nitrous oxide flux measurements under field conditions

    Science.gov (United States)

    Rannik, Ü.; Haapanala, S.; Shurpali, N. J.; Mammarella, I.; Lind, S.; Hyvönen, N.; Peltola, O.; Zahniser, M.; Martikainen, P. J.; Vesala, T.

    2015-01-01

    Four gas analysers capable of measuring nitrous oxide (N2O) concentration at a response time necessary for eddy covariance flux measurements were operated from spring until winter 2011 over a field cultivated with reed canary grass (RCG, Phalaris arundinacea, L.), a perennial bioenergy crop in eastern Finland. The instruments were TGA100A (Campbell Scientific Inc.), CW-TILDAS-CS (Aerodyne Research Inc.), N2O / CO-23d (Los Gatos Research Inc.) and QC-TILDAS-76-CS (Aerodyne Research Inc.). The period with high emissions, lasting for about 2 weeks after fertilization in late May, was characterized by an up to 2 orders of magnitude higher emission, whereas during the rest of the campaign the N2O fluxes were small, from 0.01 to 1 nmol m-2 s-1. Two instruments, CW-TILDAS-CS and N2O / CO-23d, determined the N2O exchange with minor systematic difference throughout the campaign, when operated simultaneously. TGA100A produced the cumulatively highest N2O estimates (with 29% higher values during the period when all instruments were operational). QC-TILDAS-76-CS obtained 36% lower fluxes than CW-TILDAS-CS during the first period, including the emission episode, whereas the correspondence with other instruments during the rest of the campaign was good. The reasons for systematic differences were not identified, suggesting further need for detailed evaluation of instrument performance under field conditions with emphasis on stability, calibration and any other factors that can systematically affect the accuracy of flux measurements. The instrument CW-TILDAS-CS was characterized by the lowest noise level (with a standard deviation of around 0.12 ppb at 10 Hz sampling rate) as compared to N2O / CO-23d and QC-TILDAS-76-CS (around 0.50 ppb) and TGA100A (around 2 ppb). We identified that for all instruments except CW-TILDAS-CS the random error due to instrumental noise was an important source of uncertainty at the 30 min averaging level and the total stochastic error was frequently

  10. The 183-WSL Fast Rain Rate Retrieval Algorithm. Part II: Validation Using Ground Radar Measurements

    Science.gov (United States)

    Laviola, Sante; Levizzani, Vincenzo

    2014-01-01

    The Water vapour Strong Lines at 183 GHz (183-WSL) algorithm is a method for the retrieval of rain rates and precipitation type classification (convectivestratiform), that makes use of the water vapor absorption lines centered at 183.31 GHz of the Advanced Microwave Sounding Unit module B (AMSU-B) and of the Microwave Humidity Sounder (MHS) flying on NOAA-15-18 and NOAA-19Metop-A satellite series, respectively. The characteristics of this algorithm were described in Part I of this paper together with comparisons against analogous precipitation products. The focus of Part II is the analysis of the performance of the 183-WSL technique based on surface radar measurements. The ground truth dataset consists of 2.5 years of rainfall intensity fields from the NIMROD European radar network which covers North-Western Europe. The investigation of the 183-WSL retrieval performance is based on a twofold approach: 1) the dichotomous statistic is used to evaluate the capabilities of the method to identify rain and no-rain clouds; 2) the accuracy statistic is applied to quantify the errors in the estimation of rain rates.The results reveal that the 183-WSL technique shows good skills in the detection of rainno-rain areas and in the quantification of rain rate intensities. The categorical analysis shows annual values of the POD, FAR and HK indices varying in the range 0.80-0.82, 0.330.36 and 0.39-0.46, respectively. The RMSE value is 2.8 millimeters per hour for the whole period despite an overestimation in the retrieved rain rates. Of note is the distribution of the 183-WSL monthly mean rain rate with respect to radar: the seasonal fluctuations of the average rainfalls measured by radar are reproduced by the 183-WSL. However, the retrieval method appears to suffer for the winter seasonal conditions especially when the soil is partially frozen and the surface emissivity drastically changes. This fact is verified observing the discrepancy distribution diagrams where2the 183-WSL

  11. Fast Measurement of Soluble Solid Content in Mango Based on Visible and Infrared Spectroscopy Technique

    Science.gov (United States)

    Yu, Jiajia; He, Yong

    Mango is a kind of popular tropical fruit, and the soluble solid content is an important in this study visible and short-wave near-infrared spectroscopy (VIS/SWNIR) technique was applied. For sake of investigating the feasibility of using VIS/SWNIR spectroscopy to measure the soluble solid content in mango, and validating the performance of selected sensitive bands, for the calibration set was formed by 135 mango samples, while the remaining 45 mango samples for the prediction set. The combination of partial least squares and backpropagation artificial neural networks (PLS-BP) was used to calculate the prediction model based on raw spectrum data. Based on PLS-BP, the determination coefficient for prediction (Rp) was 0.757 and root mean square and the process is simple and easy to operate. Compared with the Partial least squares (PLS) result, the performance of PLS-BP is better.

  12. Cheap and fast measuring roughness on big surfaces with an imprint method

    Science.gov (United States)

    Schopf, C.; Liebl, J.; Rascher, R.

    2017-10-01

    Roughness, shape and structure of a surface offer information on the state, shape and surface characteristics of a component. Particularly the roughness of the surface dictates the subsequent polishing of the optical surface. The roughness is usually measured by a white light interferometer, which is limited by the size of the components. Using a moulding method of surfaces that are difficult to reach, an imprint is taken and analysed regarding to roughness and structure. This moulding compound method is successfully used in dental technology. In optical production, the moulding compound method is advantageous in roughness determination in inaccessible spots or on large components (astrological optics). The "replica method" has been around in metal analysis and processing. Film is used in order to take an impression of a surface. Then, it is analysed for structures. In optical production, compound moulding seems advantageous in roughness determination in inaccessible spots or on large components (astrological optics). In preliminary trials, different glass samples with different roughness levels were manufactured. Imprints were taken from these samples (based on DIN 54150 "Abdruckverfahren für die Oberflächenprüfung"). The objective of these feasibility tests was to determine the limits of this method (smallest roughness determinable / highest roughness). The roughness of the imprint was compared with the roughness of the glass samples. By comparing the results, the uncertainty of the measuring method was determined. The spectrum for the trials ranged from rough grind (0.8 μm rms), over finishing grind (0.6 μm rms) to polishing (0.1 μm rms).

  13. Cobalt, fast neutrons and physical models: Nuclear data and measurements series

    International Nuclear Information System (INIS)

    Smith, A.B.; Guenther, P.T.; Whalen, J.F.; Lawson, R.D.

    1987-07-01

    Energy-averaged neutron total cross sections of cobalt were measured from ≅0.5 to 12.0 MeV. Differential elastic- and inelastic-scattering cross sections were measured from ≅1.5 to 10.0 MeV over the scattering-angle range ≅18 0 to 160 0 , with sufficient detail to define the energy-averaged behavior. Inelastic neutron groups were observed corresponding to ''levels'' at: 1115 +- 29, 1212 +- 24, 1307 +- 24, 1503 +- 33, 1778 +- 40, 2112 +- 40, 2224 +- 35, 2423 +- 39, 2593 +- 41 and 2810 keV. The experimental results were interpreted in terms of the spherical optical-statistical and coupled-channels models. An unusually successful description of observables was achieved over a wide energy range ( 20.0 MeV) with a spherical model having energy-dependent strengths and geometries. The energy dependencies are large below ≅7.0 MeV (i.e., ≅19.0 MeV above the Fermi energy), but become smaller and similar to those reported for ''global'' potentials at higher energies. The imaginary strength is large and decreases with energy. These imaginary-potential characteristics are attributed to neutron shell closure and collective-vibrational processes. The weak-coupling model also offers an explanation of the unusual negative energy slope and relatively small radius of the imaginary potential. The spherical optical model derived from the neutron-scattering results was extrapolated to bound energies using the dispersion relationship and the method of moments. The resulting real-potential strength and radius peak at ≅-10.0 MeV, while concurrently the real diffuseness is at a minimum. The extrapolated potential is ≅8% larger than that implied by reported particle-state energies, and ≅13% smaller than indicated by hole-state energies. 68 refs., 15 figs., 1 tab

  14. Simple, fast, and low-cost camera-based water content measurement with colorimetric fluorescent indicator

    Science.gov (United States)

    Song, Seok-Jeong; Kim, Tae-Il; Kim, Youngmi; Nam, Hyoungsik

    2018-05-01

    Recently, a simple, sensitive, and low-cost fluorescent indicator has been proposed to determine water contents in organic solvents, drugs, and foodstuffs. The change of water content leads to the change of the indicator's fluorescence color under the ultra-violet (UV) light. Whereas the water content values could be estimated from the spectrum obtained by a bulky and expensive spectrometer in the previous research, this paper demonstrates a simple and low-cost camera-based water content measurement scheme with the same fluorescent water indicator. Water content is calculated over the range of 0-30% by quadratic polynomial regression models with color information extracted from the captured images of samples. Especially, several color spaces such as RGB, xyY, L∗a∗b∗, u‧v‧, HSV, and YCBCR have been investigated to establish the optimal color information features over both linear and nonlinear RGB data given by a camera before and after gamma correction. In the end, a 2nd order polynomial regression model along with HSV in a linear domain achieves the minimum mean square error of 1.06% for a 3-fold cross validation method. Additionally, the resultant water content estimation model is implemented and evaluated in an off-the-shelf Android-based smartphone.

  15. Fast Thermal Calibration of Low-Grade Inertial Sensors and Inertial Measurement Units

    Science.gov (United States)

    Niu, Xiaoji; Li, You; Zhang, Hongping; Wang, Qingjiang; Ban, Yalong

    2013-01-01

    The errors of low-cost inertial sensors, especially Micro-Electro Mechanical Systems (MEMS) ones, are highly dependent on environmental conditions such as the temperature. Thus, there is a need for the development of accurate and reliable thermal compensation models to reduce the impact of such thermal drift of the sensors. Since the conventional thermal calibration methods are typically time-consuming and costly, an efficient thermal calibration method to investigate the thermal drift of a full set of gyroscope and accelerometer errors (i.e., biases, scale factor errors and non-orthogonalities) over the entire temperature range in a few hours is proposed. The proposed method uses the idea of the Ramp method, which removes the time-consuming process of stabilizing the sensor temperature, and addresses its inherent problems with several improvements. We change the temperature linearly for a complete cycle and take a balanced strategy by making comprehensive use of the sensor measurements during both heating and cooling processes. Besides, an efficient 8-step rotate-and-static scheme is designed to further improve the calibration accuracy and efficiency. Real calibration tests showed that the proposed method is suitable for low-grade IMUs and for both lab and factory calibration due to its efficiency and sufficient accuracy. PMID:24036581

  16. In-field Calibration of a Fast Neutron Collar for the Measurement of Fresh PWR Fuel Assemblies

    International Nuclear Information System (INIS)

    Swinhoe, Martyn Thomas; De Baere, Paul

    2015-01-01

    A new neutron collar has been designed for the measurement of fresh LEU fuel assemblies. This collar uses ''fast mode'' measurement to reduce the effect of burnable poison rods on the assay and thus reduce the dependence on the operator's declaration. The new collar design reduces effect of poison rods considerably. Instead of 12 pins of 5.2% Gd causing a 20.4% effect, as in the standard thermal mode collar, they only cause a 3.2% effect in the new collar. However it has higher efficiency so that reasonably precise measurements can be made in 25 minutes, rather than the 1 hour of previous collars. The new collar is fully compatible with the use of the standard data collection and analysis code INCC. This report describes the calibration that was made with a mock-up assembly at Los Alamos National Laboratory and with actual assemblies at the AREVA Fuel fabrication Plant in Lingen, Germany.

  17. Scanning tunneling microscopy-based in situ measurement of fast tool servo-assisted diamond turning micro-structures

    International Nuclear Information System (INIS)

    Ju, Bing-Feng; Zhu, Wu-Le; Yang, Shunyao; Yang, Keji

    2014-01-01

    We propose a new in situ measurement system based on scanning tunneling microscopy (STM) to realize spiral scanning of a micro-structure without removing it after fast tool servo (FTS) cutting. To avoid distortion of the machined and measured surface, the center alignment of the FTS tool and the STM tip was first implemented by an STM in situ raster scan of two circular grooves cut by the machine tool. To originally observe the machined surface, the trace of the STM tip is put in accord with that of the FTS by setting the same start and end points of cutting and scanning and the same feed rate, and both are triggered by the subdivided rotary encoder of the spindle of the diamond turning machine. The profile data of the in situ spiral scanning of the machined micro-lens array can be fed back to compensate the depth of the cut to guarantee sub-micron form accuracy after second machining. The efficient spiral scanning, proper matching and accurate evaluation results demonstrate that the proposed STM in situ measurement approach is of great significance to the fabrication process. (paper)

  18. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F., E-mail: lucarelli@fi.infn.it; Calzolai, G.; Chiari, M.; Giannoni, M.; Mochi, D.; Nava, S.; Carraresi, L.

    2014-01-01

    At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN in Florence, an external beam facility is fully dedicated to measurements of elemental composition of atmospheric aerosol. The experimental set-up hitherto used for this kind of applications has been upgraded with the replacement of a traditional Si(Li) detector for the detection of medium–high Z elements with a silicon drift detector (SDD) with a big active area (80 mm{sup 2}) and 450 μm thickness, with the aim of obtaining better minimum detection limits (MDL) and reduce measuring times. The Upilex extraction window has been replaced by a more resistant one (Si{sub 3}N{sub 4}). A comparison between the old Si(Li) and the new SDD for aerosol samples collected on different substrata like Teflon, Kapton and Nuclepore evidenced the better performances of the SDD. It allows obtaining better results (higher counting statistics, lower MDLs) even in shorter measuring times, thus allowing very fast analysis of both daily and hourly samples.

  19. BridgeRank: A novel fast centrality measure based on local structure of the network

    Science.gov (United States)

    Salavati, Chiman; Abdollahpouri, Alireza; Manbari, Zhaleh

    2018-04-01

    Ranking nodes in complex networks have become an important task in many application domains. In a complex network, influential nodes are those that have the most spreading ability. Thus, identifying influential nodes based on their spreading ability is a fundamental task in different applications such as viral marketing. One of the most important centrality measures to ranking nodes is closeness centrality which is efficient but suffers from high computational complexity O(n3) . This paper tries to improve closeness centrality by utilizing the local structure of nodes and presents a new ranking algorithm, called BridgeRank centrality. The proposed method computes local centrality value for each node. For this purpose, at first, communities are detected and the relationship between communities is completely ignored. Then, by applying a centrality in each community, only one best critical node from each community is extracted. Finally, the nodes are ranked based on computing the sum of the shortest path length of nodes to obtained critical nodes. We have also modified the proposed method by weighting the original BridgeRank and selecting several nodes from each community based on the density of that community. Our method can find the best nodes with high spread ability and low time complexity, which make it applicable to large-scale networks. To evaluate the performance of the proposed method, we use the SIR diffusion model. Finally, experiments on real and artificial networks show that our method is able to identify influential nodes so efficiently, and achieves better performance compared to other recent methods.

  20. Fast neutron cross section measurements. Final technical report, March 1, 1987--September 30, 1995

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1997-06-01

    The time-of-flight technique was used with the ring scattering geometry in a laboratory with low neutron scattering background to measure the angular distributions of the cross sections for elastic and inelastic scattering of 14 MeV neutrons in natural chromium, iron, nickel, and niobium. Specifically for inelastic scattering included were: the 1.43 MeV and 4.56 MeV levels of 52 Cr, the 0.85 MeV level, and (2.94-3.12) MeV and (4.46-4.51) MeV level groups of 56 Fe, the 1.33 MeV level of 60 Ni combined with the 1.45 MeV level of 58 Ni, and the 4.48 MeV level of 58 Ni. Pulses of neutrons with time width of 0.9-1.1 ns were produced via the 3 H(d,n) 4 He reaction in a 150 keV Cockcroft-Walton linear accelerator, with average intensities of 9x10 8 n/s. The energy of the incident neutrons was between 14.75 MeV (at 16 degree) and 13.48 MeV (at 160 degree). High purity scattering ring samples were used. The scattering angles ranged from ∼16 degree to ∼150 degree, for iron, chromium, and nickel, and from ∼16 degree to ∼160 degree for niobium, with a typical step of ∼10 degree. High purity ring samples were used