  1. Cross-Section Measurements in the Fast Neutron Energy Range

    Science.gov (United States)

    Plompen, Arjan

    2006-04-01

    Generation IV focuses research for advanced nuclear reactors on six concepts. Three of these concepts, the lead, gas and sodium fast reactors (LFR, GFR and SFR) have fast neutron spectra, whereas a fourth, the super-critical water reactor (SCWR), can be configured to have a fast spectrum. Such fast neutron spectra are essential to meet the sustainability objective of GenIV. Nuclear data requirements for GenIV concepts will therefore emphasize the energy region from about 1 keV to 10 MeV. Here, the potential is illustrated of the GELINA neutron time-of-flight facility and the Van de Graaff laboratory at IRMM to measure the relevant nuclear data in this energy range: the total, capture, fission and inelastic-scattering cross sections. In particular, measurement results will be shown for lead and bismuth inelastic scattering for which the need was recently expressed in a quantitative way by Aliberti et al. for Accelerator Driven Systems. Even without completion of the quantitative assessment of the data needs for GenIV concepts at ANL it is clear that this particular effort is of relevance to LFR system studies.

  2. Wide dynamic range neutron flux monitor having fast time response for the Large Helical Device

    Energy Technology Data Exchange (ETDEWEB)

    Isobe, M., E-mail: isobe@nifs.ac.jp; Takeiri, Y. [National Institute for Fusion Science, Toki 509-5292 (Japan); Department of Fusion Science, The Graduate University for Advanced Studies, Toki 509-5292 (Japan); Ogawa, K.; Miyake, H.; Hayashi, H.; Kobuchi, T. [National Institute for Fusion Science, Toki 509-5292 (Japan); Nakano, Y.; Watanabe, K.; Uritani, A. [Department of Materials, Physics and Energy Engineering, Nagoya University, Nagoya 464-8603 (Japan); Misawa, T. [Kyoto University Research Reactor Institute, Kumatori 590-0494 (Japan); Nishitani, T. [Japan Atomic Energy Agency, Rokkasho 039-3212 (Japan); Tomitaka, M.; Kumagai, T.; Mashiyama, Y.; Ito, D.; Kono, S. [Toshiba Corporation, Fuchu 183-8511 (Japan); Yamauchi, M. [Toshiba Nuclear Engineering Services Corporation, Yokohama 235-8523 (Japan)

    2014-11-15

    A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10{sup 9} counts/s. Because a maximum total neutron emission rate over 1 × 10{sup 16} n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

  3. FAST NEUTRONIC REACTOR

    Science.gov (United States)

    Snell, A.H.

    1957-12-01

    This patent relates to a reactor and process for carrying out a controlled fast neutron chain reaction. A cubical reactive mass, weighing at least 920 metric tons, of uranium metal containing predominantly U/sup 238/ and having a U/sup 235/ content of at least 7.63% is assembled and the maximum neutron reproduction ratio is limited to not substantially over 1.01 by insertion and removal of a varying amount of boron, the reactive mass being substantially freed of moderator.

  4. Average fast neutron flux in three energy ranges in the Quinta assembly irradiated by two types of beams

    Directory of Open Access Journals (Sweden)

    Strugalska-Gola Elzbieta

    2017-01-01

    Full Text Available This work was performed within the international project “Energy plus Transmutation of Radioactive Wastes” (E&T - RAW for investigations of energy production and transmutation of radioactive waste of the nuclear power industry. 89Y (Yttrium 89 samples were located in the Quinta assembly in order to measure an average high neutron flux density in three different energy ranges using deuteron and proton beams from Dubna accelerators. Our analysis showed that the neutron density flux for the neutron energy range 20.8 - 32.7 MeV is higher than for the neutron energy range 11.5 - 20.8 MeV both for protons with an energy of 0.66 GeV and deuterons with an energy of 2 GeV, while for deuteron beams of 4 and 6 GeV we did not observe this.

  5. Fast Neutron Detection with a Segmented Spectrometer

    CERN Document Server

    Langford, T J; Beise, E J; Breuer, H; Erwin, D K; Heimbach, C R; Nico, J S

    2014-01-01

    A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulse-shape discrimination The spectrometer was characterized for energy resolution and efficiency in fast neutron fields of 2.5 MeV, 14 MeV, and fission spectrum neutrons, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130 deg. N, 77.218 deg. W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.

  6. Fast neutron detection with a segmented spectrometer

    Science.gov (United States)

    Langford, T. J.; Bass, C. D.; Beise, E. J.; Breuer, H.; Erwin, D. K.; Heimbach, C. R.; Nico, J. S.

    2015-01-01

    A fast neutron spectrometer consisting of segmented plastic scintillator and 3He proportional counters was constructed for the measurement of neutrons in the energy range 1-200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulse-shape discrimination. The spectrometer was characterized for its energy response in fast neutron fields of 2.5 MeV and 14 MeV, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130°N, 77.218°W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.

  7. Fast neutron detection with a segmented spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Langford, T.J., E-mail: thomas.langford@yale.edu [Department of Physics, University of Maryland, College Park, MD 20742 (United States); Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20742 (United States); Bass, C.D. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Beise, E.J.; Breuer, H.; Erwin, D.K. [Department of Physics, University of Maryland, College Park, MD 20742 (United States); Heimbach, C.R.; Nico, J.S. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2015-01-21

    A fast neutron spectrometer consisting of segmented plastic scintillator and {sup 3}He proportional counters was constructed for the measurement of neutrons in the energy range 1–200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulse-shape discrimination. The spectrometer was characterized for its energy response in fast neutron fields of 2.5 MeV and 14 MeV, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130°N, 77.218°W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.

  8. Fast neutron imaging device and method

    Science.gov (United States)

    Popov, Vladimir; Degtiarenko, Pavel; Musatov, Igor V.

    2014-02-11

    A fast neutron imaging apparatus and method of constructing fast neutron radiography images, the apparatus including a neutron source and a detector that provides event-by-event acquisition of position and energy deposition, and optionally timing and pulse shape for each individual neutron event detected by the detector. The method for constructing fast neutron radiography images utilizes the apparatus of the invention.

  9. Determination of fast neutron flux distribution in irradiation sites of the Malaysian Nuclear Agency research reactor.

    Science.gov (United States)

    Yavar, A R; Sarmani, S B; Wood, A K; Fadzil, S M; Radir, M H; Khoo, K S

    2011-05-01

    Determination of thermal to fast neutron flux ratio (f(fast)) and fast neutron flux (ϕ(fast)) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The f(fast) and subsequently ϕ(fast) were determined using the absolute method. The f(fast) ranged from 48 to 155, and the ϕ(fast) was found in the range 1.03×10(10)-4.89×10(10) n cm(-2) s(-1). These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.

  10. Compositional terranes on Mercury: Information from fast neutrons

    Science.gov (United States)

    Lawrence, David J.; Peplowski, Patrick N.; Beck, Andrew W.; Feldman, William C.; Frank, Elizabeth A.; McCoy, Timothy J.; Nittler, Larry R.; Solomon, Sean C.

    2017-01-01

    We report measurements of the flux of fast neutrons at Mercury from 20ºS to the north pole. On the basis of neutron transport simulations and remotely sensed elemental compositions, cosmic-ray-induced fast neutrons are shown to provide a measure of average atomic mass, , a result consistent with earlier studies of the Moon and Vesta. The dynamic range of fast neutron flux at Mercury is 3%, which is smaller than the fast-neutron dynamic ranges of 30% and 6% at the Moon and Vesta, respectively. Fast-neutron data delineate compositional terranes on Mercury that are complementary to those identified with X-ray, gamma-ray, and slow-neutron data. Fast neutron measurements confirm the presence of a region with high , relative to the mean for the planet, that coincides with the previously identified high-Mg region and reveal the existence of at least two additional compositional terranes: a low- region within the northern smooth plains and a high- region near the equator centered near 90ºE longitude. Comparison of the fast-neutron map with elemental composition maps show that variations predicted from the combined element maps are not consistent with the measured variations in fast-neutron flux. This lack of consistency could be due to incomplete coverage for some elements or uncertainties in the interpretations of compositional and neutron data. Currently available data and analyses do not provide sufficient constraints to resolve these differences.

  11. Fast neutron environments.

    Energy Technology Data Exchange (ETDEWEB)

    Buchheit, Thomas Edward; Kotula, Paul Gabriel; Lu, Ping; Brewer, Luke N. (Naval Postgraduate School, Monterey, CA); Goods, Steven Howard (Sandia National Laboratories, Livermore, CA); Foiles, Stephen Martin; Puskar, Joseph David; Hattar, Khalid Mikhiel; Doyle, Barney Lee; Boyce, Brad Lee; Clark, Blythe G.

    2011-10-01

    The goal of this LDRD project is to develop a rapid first-order experimental procedure for the testing of advanced cladding materials that may be considered for generation IV nuclear reactors. In order to investigate this, a technique was developed to expose the coupons of potential materials to high displacement damage at elevated temperatures to simulate the neutron environment expected in Generation IV reactors. This was completed through a high temperature high-energy heavy-ion implantation. The mechanical properties of the ion irradiated region were tested by either micropillar compression or nanoindentation to determine the local properties, as a function of the implantation dose and exposure temperature. In order to directly compare the microstructural evolution and property degradation from the accelerated testing and classical neutron testing, 316L, 409, and 420 stainless steels were tested. In addition, two sets of diffusion couples from 316L and HT9 stainless steels with various refractory metals. This study has shown that if the ion irradiation size scale is taken into consideration when developing and analyzing the mechanical property data, significant insight into the structural properties of the potential cladding materials can be gained in about a week.

  12. Measurement of fast neutrons and secondary gamma rays in graphite

    Energy Technology Data Exchange (ETDEWEB)

    Makarious, A.S.; El-Asyd Abdo, A.; Kansouh, W.A. [Atomic Energy Authority, Cairo (Egypt). Nuclear Research Centre; Bashter, I.I. [Zagazig Univ. (Egypt). Faculty of Science

    1996-05-01

    The spatial fluxes and energy distributions of fast neutrons, total gamma rays and secondary gamma rays transmitted through different thicknesses of graphite have been measured. The graphite samples were arranged in front of one of the horizontal channels of the ET-RR-1 reactor. Gamma ray measurements were carried out for bare, cadmium filtered and boron carbide filtered reactor beams. A fast neutron and gamma ray spectrometer with a stilbene crystal was used to measure the spectrum of fast neutrons and gamma rays. Pulse shape discrimination using the zero cross over technique was used to distinguish the proton pulses from the electron pulses. The total fast neutrons macroscopic cross section and the linear attenuation coefficient for gamma rays were derived both for the whole energy range and at different energies. The obtained values were used to calculate the relaxation lengths for fast neutrons and gamma rays. (Author).

  13. [Fast neutron cross section measurements

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, G.F.

    1992-10-26

    From its inception, the Nuclear Data Project at the University of Michigan has concentrated on two major objectives: (1) to carry out carefully controlled nuclear measurements of the highest possible reliability in support of the national nuclear data program, and (2) to provide an educational opportunity for students with interests in experimental nuclear science. The project has undergone a successful transition from a primary dependence on our photoneutron laboratory to one in which our current research is entirely based on a unique pulsed 14 MeV fast neutron facility. The new experimental facility is unique in its ability to provide nanosecond bursts of 14 MeV neutrons under conditions that are clean'' and as scatter-free as possible, and is the only one of its type currently in operation in the United States. It has been designed and put into operation primarily by graduate students, and has met or exceeded all of its important initial performance goals. We have reached the point of its routine operation, and most of the data are now in hand that will serve as the basis for the first two doctoral dissertations to be written by participating graduate students. Our initial results on double differential neutron cross sections will be presented at the May 1993 Fusion Reactor Technology Workshop. We are pleased to report that, after investing several years in equipment assembly and optimization, the project has now entered its data production'' phase.

  14. Capture-Gated Fast Neutron Spectroscopy

    Science.gov (United States)

    Mumm, H. P.; Abdurashitov, J. N.; Beise, E. J.; Breuer, H.; Gavrin, V. N.; Heimbach, C. R.; Langford, T. J.; Mendenhall, M.; Nico, J. S.; Shikhin, A. A.

    2015-10-01

    We present recent developments in fast neutron detection using segmented spectrometers based on the principle of capture-gating. Our approach employs an organic scintillator to detect fast neutrons through their recoil interaction with protons in the scintillator. The neutrons that thermalize and are captured produce a signal indicating that the event was due to a neutron recoil and that the full energy of the neutron was deposited. The delayed neutron capture also serves to discriminate against uncorrelated background events. The segmentation permits reconstruction of the initial neutron energy despite the nonlinear response of the scintillator. We have constructed spectrometers using both He-3 proportional counters and Li-6 doping as capture agents in plastic and liquid organic scintillators. We discuss the operation of the spectrometers for the measurement of low levels of fast neutrons for several applications, including the detection of very low-activity neutron sources and the characterization of the flux and spectrum of fast neutrons at the Earth's surface and in the underground environment.

  15. A Fast Neutron Spectrometer for Underground Science

    Science.gov (United States)

    Langford, Thomas; Beise, Elizabeth; Breuer, Herbert; Erwin, Dylan; Bass, Christopher; Heimbach, Craig; Nico, Jeff

    2010-02-01

    The characterization of the fast neutron fluence has become a critical issue for experiments that require extreme low-background environments, such as neutrino-less double-beta decay, dark matter searches, and solar neutrino experiments. In such experiments, fast neutrons may be the dominant and a potentially irreducible background, thus necessitating precise information about the fast neutron fluence and energy spectrum. The most reasonable approach to addressing the problem is through the complete characterization of the neutrons through both site-specific measurement and benchmarking of simulation codes. We will discuss the progress toward the development of a large-volume, segmented detector consisting of plastic scintillator and ^3He proportional counters. The detector will be placed in an underground environment to measure the fast neutron flux and energy spectrum. A prototype detector has been constructed and testing is in progress. We will discuss the status of the project and present data from the prototype detector. )

  16. Fast-neutron, coded-aperture imager

    Energy Technology Data Exchange (ETDEWEB)

    Woolf, Richard S., E-mail: richard.woolf@nrl.navy.mil; Phlips, Bernard F., E-mail: bernard.phlips@nrl.navy.mil; Hutcheson, Anthony L., E-mail: anthony.hutcheson@nrl.navy.mil; Wulf, Eric A., E-mail: eric.wulf@nrl.navy.mil

    2015-06-01

    This work discusses a large-scale, coded-aperture imager for fast neutrons, building off a proof-of concept instrument developed at the U.S. Naval Research Laboratory (NRL). The Space Science Division at the NRL has a heritage of developing large-scale, mobile systems, using coded-aperture imaging, for long-range γ-ray detection and localization. The fast-neutron, coded-aperture imaging instrument, designed for a mobile unit (20 ft. ISO container), consists of a 32-element array of 15 cm×15 cm×15 cm liquid scintillation detectors (EJ-309) mounted behind a 12×12 pseudorandom coded aperture. The elements of the aperture are composed of 15 cm×15 cm×10 cm blocks of high-density polyethylene (HDPE). The arrangement of the aperture elements produces a shadow pattern on the detector array behind the mask. By measuring of the number of neutron counts per masked and unmasked detector, and with knowledge of the mask pattern, a source image can be deconvolved to obtain a 2-d location. The number of neutrons per detector was obtained by processing the fast signal from each PMT in flash digitizing electronics. Digital pulse shape discrimination (PSD) was performed to filter out the fast-neutron signal from the γ background. The prototype instrument was tested at an indoor facility at the NRL with a 1.8-μCi and 13-μCi 252Cf neutron/γ source at three standoff distances of 9, 15 and 26 m (maximum allowed in the facility) over a 15-min integration time. The imaging and detection capabilities of the instrument were tested by moving the source in half- and one-pixel increments across the image plane. We show a representative sample of the results obtained at one-pixel increments for a standoff distance of 9 m. The 1.8-μCi source was not detected at the 26-m standoff. In order to increase the sensitivity of the instrument, we reduced the fastneutron background by shielding the top, sides and back of the detector array with 10-cm-thick HDPE. This shielding configuration led

  17. Point Scattered Function (PScF) for fast neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Mohamed H. [Nuclear and Radiation Engineering Department, Alexandria University, Alexandria 21544 (Egypt)], E-mail: mhmheg@yahoo.com

    2009-08-01

    Fast neutron radiography opened up a new range of possibilities to image extremely dense objects. The removal of the scattering effect is one of the most challenging problems in neutron imaging. Neutron scattering in fast neutron radiography did not receive much attention compared with X-ray and thermal neutron radiography. The purpose of this work is to investigate the behavior of the Point Scattered Function (PScF) as applied in fast neutron radiography. The PScF was calculated using MCNP as a spatial distribution of scattered neutrons over the detector surface for one emitting source element. Armament and explosives materials, namely, Rifle steel, brass, aluminum and trinitrotoluene (TNT) were simulated. Effect of various sample thickness and sample-to-detector distance were considered. Simulated sample geometries included a slab with varying thickness, a sphere with varying radii, and a cylinder with varying base radii. Different neutron sources, namely, Cf-252, DT as well as DD neutron sources were considered. Neutron beams with zero degree divergence angle; and beams with varying angles related to the normal to the source plane were simulated. Curve fitting of the obtained PScF, in the form of Gaussian function, were given to be used in future work using image restoration codes. Analytical representation of the height as well as the Full Width at Half Maximum (FWHM) of the obtained Gaussian functions eliminates the need to calculate the PScF for sample parameters that were not investigated in this study.

  18. Narcotics detection using fast-neutron interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Micklich, B.J.; Fink, C.L.

    1995-12-31

    Fast-neutron interrogation techniques are being investigated for detection of narcotics in luggage and cargo containers. This paper discusses two different fast-neutron techniques. The first uses a pulsed accelerator or sealed-tube source to produce monoenergetic fast neutrons. Gamma rays characteristic of carbon and oxygen are detected and the elemental densities determined. Spatial localization is accomplished by either time of flight or collimators. This technique is suitable for examination of large containers because of the good penetration of the fast neutrons and the low attenuation of the high-energy gamma rays. The second technique uses an accelerator to produce nanosecond pulsed beams of deuterons that strike a target to produce a pulsed beam of neutrons with a continuum of energies. Elemental distributions are obtained by measuring the neutron spectrum after the source neutrons pass through the items being interrogated. Spatial variation of elemental densities is obtained by tomographic reconstruction of projection data obtained for three to five angles and relatively low (2 cm) resolution. This technique is best suited for examination of luggage or small containers with average neutron transmissions greater than about 0.01. Analytic and Monte-Carlo models are being used to investigate the operational characteristics and limitations of both techniques.

  19. Determination of fast neutron flux distribution in irradiation sites of the Malaysian Nuclear Agency research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yavar, A.R. [School of Applied Physics, Faculty of Science and Technology, National University of Malaysia (UKM), 43600 Bangi, Selangor (Malaysia); Sarmani, S.B. [School of Chemical Sciences and Food Technology, Faculty of Science and Technology, National University of Malaysia (UKM), 43600 Bangi, Selangor (Malaysia); Wood, A.K. [Analytical Chemistry Application Group, Industrial Technology Division, Malaysian Nuclear Agency (MNA), Bangi, 43000 Kajang, Selangor (Malaysia); Fadzil, S.M. [School of Applied Physics, Faculty of Science and Technology, National University of Malaysia (UKM), 43600 Bangi, Selangor (Malaysia); Radir, M.H. [Analytical Chemistry Application Group, Industrial Technology Division, Malaysian Nuclear Agency (MNA), Bangi, 43000 Kajang, Selangor (Malaysia); Khoo, K.S., E-mail: khoo@ukm.m [School of Applied Physics, Faculty of Science and Technology, National University of Malaysia (UKM), 43600 Bangi, Selangor (Malaysia)

    2011-05-15

    Determination of thermal to fast neutron flux ratio (f{sub fast}) and fast neutron flux ({phi}{sub fast}) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The f{sub fast} and subsequently {phi}{sub fast} were determined using the absolute method. The f{sub fast} ranged from 48 to 155, and the {phi}{sub fast} was found in the range 1.03x10{sup 10}-4.89x10{sup 10} n cm{sup -2} s{sup -1}. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.

  20. Fast neutron activation dosimetry with TLDS

    Energy Technology Data Exchange (ETDEWEB)

    Pearson, D.W.; Moran, P.R.

    1975-01-01

    Fast neutron activation using threshold reactions is the only neutron dosimetry method which offers complete discrimination against gamma-rays and preserves some information about the neutron energy. Conventional activation foil technique requires sensitive radiation detectors to count the decay of the neutron induced activity. For extensive measurements at low neutron fluences, vast outlays of counting equipment are required. TL dosimeters are inexpensive, extremely sensitive radiation detectors. The work of Mayhugh et al. (Proc. Third Int. Conf. on Luminescence Dosimetry, Riso Report 249, 1040, (1971)) showed that CaSO/sub 4/: DyTLDs could be used to measure the integrated dose from the decay of the radioactivity produced in the dosimeters by exposure to thermal neutrons. This neatly combines the activation detector and counter functions in one solid state device. This work has been expanded to fast neutron exposures and other TL phosphors. The reactions /sup 19/F(n, 2n)/sup 18/F, /sup 32/S(n,p)/sup 32/P, /sup 24/Mg(n,p)/sup 24/, and /sup 64/Zn(n,p)/sup 64/Cu were found useful for fast neutron activation in commercial TLDs. As each TLD is its own integrating decay particle counter, many activation measurements can be made at the same time. The subsequent readings of the TL signals can be done serially after the induced radioactivity has decayed, using only one TL reader. The neutron detection sensitivity is limited mainly by the number statistics of the neutron activations. The precision of the neutron measurement is within a factor of two of conventional foil activation for comparable mass detectors. Commercially available TLDs can measure neutron fluences of 10/sup 9/n/cm/sup 2/ with 10 percent precision.

  1. Design of a transportable high efficiency fast neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Roecker, C., E-mail: calebroecker@berkeley.edu [Department of Nuclear Engineering, University of California at Berkeley, CA 94720 (United States); Bernstein, A.; Bowden, N.S. [Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Cabrera-Palmer, B. [Radiation and Nuclear Detection Systems, Sandia National Laboratories, Livermore, CA 94550 (United States); Dazeley, S. [Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Gerling, M.; Marleau, P.; Sweany, M.D. [Radiation and Nuclear Detection Systems, Sandia National Laboratories, Livermore, CA 94550 (United States); Vetter, K. [Department of Nuclear Engineering, University of California at Berkeley, CA 94720 (United States); Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2016-08-01

    A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV and a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm{sup 2} rising to 5000 cm{sup 2}. For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm{sup 2} and 2500 cm{sup 2}. The multiplicity mode was found to be sensitive to the incident neutron angular distribution.

  2. Comparison of Fast Neutron Detector Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Stange, Sy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mckigney, Edward Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-02-09

    This report documents the work performed for the Department of Homeland Security Domestic Nuclear Detection O ce as the project Fast Neutron Detection Evaluation under contract HSHQDC-14-X-00022. This study was performed as a follow-on to the project Study of Fast Neutron Signatures and Measurement Techniques for SNM Detection - DNDO CFP11-100 STA-01. That work compared various detector technologies in a portal monitor con guration, focusing on a comparison between a number of fast neutron detection techniques and two standard thermal neutron detection technologies. The conclusions of the earlier work are contained in the report Comparison of Fast Neutron Detector Technologies. This work is designed to address questions raised about assumptions underlying the models built for the earlier project. To that end, liquid scintillators of two di erent sizes{ one a commercial, o -the-shelf (COTS) model of standard dimensions and the other a large, planer module{were characterized at Los Alamos National Laboratory. The results of those measurements were combined with the results of the earlier models to gain a more complete picture of the performance of liquid scintillator as a portal monitor technology.

  3. FNIT: the fast neutron imaging telescope for SNM detection

    Science.gov (United States)

    Bravar, Ulisse; Bruillard, Paul J.; Flückiger, Erwin O.; Macri, John R.; McConnell, Mark L.; Moser, Michael R.; Ryan, James M.

    2006-05-01

    We report on recent progress in the development of the Fast Neutron Imaging Telescope (FNIT), a detector with both imaging and energy measurement capabilities, sensitive to neutrons in the 2-20 MeV range. FNIT was initially conceived to study solar neutrons as a candidate design for the Solar Sentinels program under formulation at NASA. This instrument is now being configured to locate fission neutron sources for homeland security purposes. By accurately identifying the position of the neutron source with imaging techniques and reconstructing the energy spectrum of fission neutrons, FNIT can locate problematic amounts of Special Nuclear Material (SNM), including heavily shielded and masked samples. The detection principle is based on multiple elastic neutron-proton (n-p) scatterings in organic scintillators. By reconstructing the n-p event locations and sequence and measuring the recoil proton energies, the direction and energy spectrum of the primary neutron flux can be determined and neutron point sources identified. The performance of FNIT is being evaluated through a series of Monte Carlo simulations and lab tests of detector prototypes. The Science Model One (SM1) of this instrument was recently assembled and is presently undergoing performance testing.

  4. Plastic fiber scintillator response to fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Danly, C. R.; Sjue, S.; Wilde, C. H.; Merrill, F. E.; Haight, R. C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States)

    2014-11-15

    The Neutron Imaging System at NIF uses an array of plastic scintillator fibers in conjunction with a time-gated imaging system to form an image of the neutron emission from the imploded capsule. By gating on neutrons that have scattered from the 14.1 MeV DT energy to lower energy ranges, an image of the dense, cold fuel around the hotspot is also obtained. An unmoderated spallation neutron beamline at the Weapons Neutron Research facility at Los Alamos was used in conjunction with a time-gated imaging system to measure the yield of a scintillating fiber array over several energy bands ranging from 1 to 15 MeV. The results and comparison to simulation are presented.

  5. Neutron spectrometer for fast nuclear reactors

    CERN Document Server

    Osipenko, M; Ricco, G; Caiffi, B; Pompili, F; Pillon, M; Angelone, M; Verona-Rinati, G; Cardarelli, R; Mila, G; Argiro, S

    2015-01-01

    In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on $^6$Li into $\\alpha$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\\times 10^{-4}$ to 3.5$\\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$\\alpha$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.

  6. Fission-neutrons source with fast neutron-emission timing

    Energy Technology Data Exchange (ETDEWEB)

    Rusev, G., E-mail: rusev@lanl.gov; Baramsai, B.; Bond, E.M.; Jandel, M.

    2016-05-01

    A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of {sup 252}Cf. The time is provided by registering the fission fragments in a layer of a thin scintillation film with a signal rise time of 1 ns. The scintillation light output is measured by two silicon photomultipliers with rise time of 0.5 ns. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements using it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is given.

  7. Superconducting High Resolution Fast-Neutron Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Hau, Ionel Dragos [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Superconducting high resolution fast-neutron calorimetric spectrometers based on 6LiF and TiB{sub 2} absorbers have been developed. These novel cryogenic spectrometers measure the temperature rise produced in exothermal (n, α) reactions with fast neutrons in 6Li and 10B-loaded materials with heat capacity C operating at temperatures T close to 0.1 K. Temperature variations on the order of 0.5 mK are measured with a Mo/Cu thin film multilayer operated in the transition region between its superconducting and its normal state. The advantage of calorimetry for high resolution spectroscopy is due to the small phonon excitation energies kBT on the order of μeV that serve as signal carriers, resulting in an energy resolution ΔE ~ (kBT2C)1/2, which can be well below 10 keV. An energy resolution of 5.5 keV has been obtained with a Mo/Cu superconducting sensor and a TiB2 absorber using thermal neutrons from a 252Cf neutron source. This resolution is sufficient to observe the effect of recoil nuclei broadening in neutron spectra, which has been related to the lifetime of the first excited state in 7Li. Fast-neutron spectra obtained with a 6Li-enriched LiF absorber show an energy resolution of 16 keV FWHM, and a response in agreement with the 6Li(n, α)3H reaction cross section and Monte Carlo simulations for energies up to several MeV. The energy resolution of order of a few keV makes this novel instrument applicable to fast-neutron transmission spectroscopy based on the unique elemental signature provided by the neutron absorption and scattering resonances. The optimization of the energy resolution based on analytical and numerical models of the detector response is discussed in the context of these applications.

  8. Development of imaging techniques for fast neutron radiography in Japan

    CERN Document Server

    Fujine, S; Yoshii, K; Kamata, M; Tamaki, M; Ohkubo, K; Ikeda, Y; Kobayashi, H

    1999-01-01

    Neutron radiography with fast neutron beams (FNR) has been studied at the fast neutron source reactor 'YAYOI' of the University of Tokyo since 1986. Imaging techniques for FNR have been developed for CR-39 track-etch detector, electronic imaging system (television method), direct film method, imaging plate and also fast and thermal neutron concurrent imaging method. The review of FNR imaging techniques and some applications are reported in this paper.

  9. Inelastic scattering of fast neutrons from $^{56}$Fe

    CERN Document Server

    Beyer, R; Hannaske, R; Junghans, A R; Massarczyk, R; Anders, M; Bemmerer, D; Ferrari, A; Kögler, T; Röder, M; Schmidt, K; Wagner, A

    2014-01-01

    Inelastic scattering of fast neutrons from $^{56}$Fe was studied at the photoneutron source nELBE. The neutron energies were determined on the basis of a timeof- flight measurement. Gamma-ray spectra were measured with a high-purity germanium detector. The total scattering cross sections deduced from the present experiment in an energy range from 0.8 to 9.6 MeV agree within 15% with earlier data and with predictions of the statistical-reaction code Talys.

  10. MPACT Fast Neutron Multiplicity System Design Concepts

    Energy Technology Data Exchange (ETDEWEB)

    D. L. Chichester; S. A. Pozzi; J. L. Dolan; M. T. Kinlaw; A. C. Kaplan; M. Flaska; A. Enqvist; J. T. Johnsom; S. M. Watson

    2012-10-01

    This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most

  11. Methods and Instruments for Fast Neutron Detection

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Reeder, Paul L.; Cooper, Matthew W.; McCormick, Kathleen R.; Peurrung, Anthony J.; Warren, Glen A.

    2005-05-01

    Pacific Northwest National Laboratory evaluated the performance of a large-area (~0.7 m2) plastic scintillator time-of-flight (TOF) sensor for direct detection of fast neutrons. This type of sensor is a readily area-scalable technology that provides broad-area geometrical coverage at a reasonably low cost. It can yield intrinsic detection efficiencies that compare favorably with moderator-based detection methods. The timing resolution achievable should permit substantially more precise time windowing of return neutron flux than would otherwise be possible with moderated detectors. The energy-deposition threshold imposed on each scintillator contributing to the event-definition trigger in a TOF system can be set to blind the sensor to direct emission from the neutron generator. The primary technical challenge addressed in the project was to understand the capabilities of a neutron TOF sensor in the limit of large scintillator area and small scintillator separation, a size regime in which the neutral particle’s flight path between the two scintillators is not tightly constrained.

  12. Measurements of fast neutrons by bubble detectors

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, F.; Martinez, H. [Laboratorio de Espectroscopia, Instituto de Ciencias Fisicas, Universidad Nacional Autonoma de Mexico, Apartado Postal 48-3, 62251, Cuernavaca Morelos (Mexico); Leal, B. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Apartado Postal 70-543, 04510, Ciudad Universitaria, Mexico D. F. (Mexico); Rangel, J. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Apartado Postal 70-543, 04510, Ciudad Universitaria, Mexico D. F (Mexico); Reyes, P. G. [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico, Instituto Literario 100, Col. Centro, 50000, Toluca Estado de Mexico (Mexico)

    2013-07-03

    Neutron bubble detectors have been studied using Am-Be and D-D neuron sources, which give limited energy information. The Bubble Detector Spectrometer (BDS) have six different energy thresholds ranging from 10 KeV to 10 Mev. The number of bubbles obtained in each measurement is related to the dose (standardized response R) equivalent neutrons through sensitivity (b / {mu}Sv) and also with the neutron flux (neutrons per unit area) through a relationship that provided by the manufacturer. Bubble detectors were used with six different answers (0.11 b/ {mu}Sv, 0093 b/{mu}Sv, 0.14 b/{mu}Sv, 0.17 b/{mu}Sv, 0051 b/{mu}Sv). To test the response of the detectors (BDS) radiate a set of six of them with different energy threshold, with a source of Am-Be, placing them at a distance of one meter from it for a few minutes. Also, exposed to dense plasma focus Fuego Nuevo II (FN-II FPD) of ICN-UNAM, apparatus which produces fusion plasma, generating neutrons by nuclear reactions of neutrons whose energy emitting is 2.45 MeV. In this case the detectors were placed at a distance of 50 cm from the pinch at 90 Degree-Sign this was done for a certain number of shots. In both cases, the standard response is reported (Dose in {mu}Sv) for each of the six detectors representing an energy range, this response is given by the expression R{sub i}= B{sub i} / S{sub i} where B{sub i} is the number of bubbles formed in each and the detector sensitivity (S{sub i}) is given for each detector in (b / {mu}Sv). Also, reported for both cases, the detected neutron flux (n cm{sup -2}), by a given ratio and the response involves both standardized R, as the average cross section sigma. The results obtained have been compared with the spectrum of Am-Be source. From these measurements it can be concluded that with a combination of bubble detectors, with different responses is possible to measure the equivalent dose in a range of 10 to 100 {mu}Sv fields mixed neutron and gamma, and pulsed generated fusion

  13. Fast and thermal neutron profiles for a 25-MV x-ray beam.

    Science.gov (United States)

    Price, K W; Nath, R; Holeman, G R

    1978-01-01

    High-energy x-ray radiotherapy machines generate neutrons by photonuclear reactions in the target and the treatment head and expose the patient to a neutron flux. In order to evaluate the neutron exposure quantitatively, fast and thermal neutron profiles for 25-MV x-ray beams of the Sagittaire accelerator have been measured. An activation technique, using the reactions 31P(n, gamma)32P (thermal neutrons) and 31P(n, p)31Si (fast neutrons, E greater than 0.7 MeV), has been developed to measure fast- and thermal-neutron fluxes in an intense high-energy photon flux. The sensitivity of this activation detector to high-energy photons, which has plagued many previous neutron measurements, was carefully measured and found to be less than 4%. Neutron fluxes for various photon field sizes ranging from 5 X 5 cm to 30 X 30 cm have been measured. The fast-neutron profiles were observed to have rounded edges and the thermal fluxes were found to be relatively uniform. In the central part of the x-ray beam, the ratio of neutron dose equivalent to photon absorbed dose was found to be between 0.2% and 0.5%. Outside of the photon field, the ratio of neutron dose equivalent to the central-axis photon absorbed dose was 0.12%.

  14. [Fast neutron cross section measurements]. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, G.F.

    1992-10-26

    From its inception, the Nuclear Data Project at the University of Michigan has concentrated on two major objectives: (1) to carry out carefully controlled nuclear measurements of the highest possible reliability in support of the national nuclear data program, and (2) to provide an educational opportunity for students with interests in experimental nuclear science. The project has undergone a successful transition from a primary dependence on our photoneutron laboratory to one in which our current research is entirely based on a unique pulsed 14 MeV fast neutron facility. The new experimental facility is unique in its ability to provide nanosecond bursts of 14 MeV neutrons under conditions that are ``clean`` and as scatter-free as possible, and is the only one of its type currently in operation in the United States. It has been designed and put into operation primarily by graduate students, and has met or exceeded all of its important initial performance goals. We have reached the point of its routine operation, and most of the data are now in hand that will serve as the basis for the first two doctoral dissertations to be written by participating graduate students. Our initial results on double differential neutron cross sections will be presented at the May 1993 Fusion Reactor Technology Workshop. We are pleased to report that, after investing several years in equipment assembly and optimization, the project has now entered its ``data production`` phase.

  15. MPACT Fast Neutron Multiplicity System Prototype Development

    Energy Technology Data Exchange (ETDEWEB)

    D.L. Chichester; S.A. Pozzi; J.L. Dolan; M.T. Kinlaw; S.J. Thompson; A.C. Kaplan; M. Flaska; A. Enqvist; J.T. Johnson; S.M. Watson

    2013-09-01

    This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

  16. Photon and fast neutron dosimetry using aluminium oxide thermoluminescence dosemeters.

    Science.gov (United States)

    Santos, J P; Fernandes, A C; Gonçalves, I C; Marques, J G; Carvalho, A F; Santos, L; Cardoso, J; Osvay, M

    2006-01-01

    Al(2)O(3):Mg,Y thermoluminescence (TL) dosemeters were used to measure photon and fast neutron doses in a fast neutron beam recently implemented at the Portuguese Research Reactor, Nuclear and Technological Institute, Portugal. The activation of Al(2)O(3):Mg,Y by fast neutrons provides information about the fast neutron component by measuring the activity of the reaction products and the self-induced TL signal. Additionally, the first TL reading after irradiation determines the photon dose. The elemental composition of the dosemeters was determined by instrumental neutron activation analysis and by particle induced X-ray emission. Results demonstrate that Al(2)O(3):Mg,Y is an adequate material to discriminate photon and fast neutron fields for reactor dosimetry purposes.

  17. High-sensitive spectrometer of fast neutrons and the results of fast neutron background flux measurements at the Gallium-Germanium Solar Neutrino Experiment

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S

    2002-01-01

    The principle of operation, design, registration system and main characteristics of a fast neutron spectrometer are described. The spectrometer is intended for direct measurements of ultra low fluxes of fast neutrons. It is sensitive to neutron fluxes of 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 and lower. The detection efficiency of fast neutrons with simultaneous energy measurement was determined from Monte-Carlo simulation to be equal to 0.11+-0.01. The background counting rate in the detector corresponds to a neutron flux of (6.5+-2.1)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The natural neutron flux from the surrounding mine rock at the depth of 4600 m of water equivalent was measured to be (7.3+-2.4)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The flux of fast neutrons in the SAGE main room was measured to be <2.3x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in 1.0-11.0 MeV energy range.

  18. Effects of fast neutrons on chromatin: dependence on chromatin structure

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L. [Dept. of Molecular Genetics, V. Babes National Inst., Bd. Timisoara, Bucharest (Romania); Constantinescu, B. [Dept. of Cyclotron, H. Hulubei National Inst., Bucharest (Romania); Gazdaru, D. [Dept. of Biophysics, Physics Faculty, Univ. of Bucharest (Romania)

    2002-07-01

    The effects of fast neutrons (10-100 Gy) on chromatin extracted from normal (liver of Wistar rats) and tumor (Walker carcinosarcoma maintained on Wistar rats) tissues were compared. The spectroscopic assays used were (i) chromatin intrinsic fluorescence, (ii) time-resolved fluorescence of chromatin-proflavine complexes, and (iii) fluorescence resonance energy transfer (FRET) between dansyl chloride and acridine orange coupled to chromatin. For both normal and tumor chromatin, the intensity of intrinsic fluorescence specific for acidic and basic proteins decreased with increasing dose. The relative contributions of the excited-state lifetime of proflavine bound to chromatin were reduced upon fast-neutron irradiation, indicating a decrease in the proportion of chromatin DNA available for ligand binding. The Forster energy transfer efficiencies were also modified by irradiation. These effects were larger for chromatin from tumor tissue. In the range 0-100 Gy, fast neutrons induced alterations in DNA and acidic and basic proteins, as well as in global chromatin structure. The radiosensitivity of chromatin extracted from tumor tissue seems to be higher than that of chromatin extracted from normal tissue, probably because of its higher euchromatin (loose)-heterochromatin (compact) ratio. (author)

  19. Development of fast neutron pinhole camera using nuclear emulsion for neutron emission profile measurement in KSTAR

    Science.gov (United States)

    Izumi, Y.; Tomita, H.; Nakayama, Y.; Hayashi, S.; Morishima, K.; Isobe, M.; Cheon, M. S.; Ogawa, K.; Nishitani, T.; Naka, T.; Nakano, T.; Nakamura, M.; Iguchi, T.

    2016-11-01

    We have developed a compact fast neutron camera based on a stack of nuclear emulsion plates and a pinhole collimator. The camera was installed at J-port of Korea superconducting tokamak advanced research at National Fusion Research Institute, Republic of Korea. Fast neutron images agreed better with calculated ones based on Monte Carlo neutron simulation using the uniform distribution of Deuterium-Deuterium (DD) neutron source in a torus of 40 cm radius.

  20. Analysis of a measured neutron background below 6 MeV for fast-neutron imaging systems

    Science.gov (United States)

    Ide, K.; Becchetti, M. F.; Flaska, M.; Poitrasson-Riviere, A.; Hamel, M. C.; Polack, J. K.; Lawrence, C. C.; Clarke, S. D.; Pozzi, S. A.

    2012-12-01

    Detailed and accurate information on the neutron background is relevant for many applications that involve radiation detection, both for non-coincidence and coincidence countings. In particular, for the purpose of developing advanced neutron-detection techniques for nuclear non-proliferation and nuclear safeguards, the energy-dependent, ground-level, neutron-background information is needed. There are only a few previous studies available about the neutron background below 10 MeV, which is a typical neutron energy range of interest for nuclear non-proliferation and nuclear-safeguards applications. Thus, there is a potential for further investigation in this energy range. In this paper, neutron-background measurement results using organic-liquid scintillation detectors are described and discussed, with a direct application in optimization simulations of a fast-neutron imager based on liquid scintillators. The measurement was performed in summer 2011 in Ann Arbor, Michigan, USA, and the measurement setup consisted of several EJ-309 liquid scintillators and a fast waveform digitizer. The average neutron flux below 6 MeV was measured to be approximately 4e-4 counts/cm2/s. In addition, the relationship between the neutron-background count rate and various environmental quantities, such as humidity, at Earth's ground level was investigated and the results did not reveal any straightforward dependences. The measured pulse height distribution (PHD) was unfolded to determine the energy spectrum of the background neutrons. The unfolded neutron-background spectrum was implemented to a previously-created MCNPX-PoliMi model of the neutron-scatter camera and simple-backprojection images of the background neutrons were acquired. Furthermore, a simulated PHD was obtained with the MCNPX-PoliMi code using the "Cosmic-Ray Shower Library" (CRY) source sub-routine which returns various types of radiation, including neutrons and photons at a surface, and accounts for solar cycle

  1. Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator

    CERN Document Server

    Lee, Seung Kyu; Kim, Gi-Dong; Kim, Yong-Kyun

    2011-01-01

    Various neutron diagnostic tools are used in fusion reactors to evaluate different aspects of plasma performance, such as fusion power, power density, ion temperature, fast ion energy, and their spatial distributions. The stilbene scintillator has been proposed for use as a neutron diagnostic system to measure the characteristics of neutrons from the Korea Superconducting Tokamak Advanced Research (KSTAR) fusion reactor. Specially designed electronics are necessary to measure fast neutron spectra with high radiation from a gamma-ray background. The signals from neutrons and gamma-rays are discriminated by the digital charge pulse shape discrimination (PSD) method, which uses total to partial charge ratio analysis. The signals are digitized by a flash analog-to-digital convertor (FADC). To evaluate the performance of the fabricated stilbene neutron diagnostic system, the efficiency of 10 mm soft-iron magnetic shielding and the detection efficiency of fast neutrons were tested experimentally using a 252Cf neutr...

  2. Characterization of a GEM-based fast neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, B., E-mail: basilio.esposito@enea.it [Associazione Euratom-ENEA sulla Fusione, Via E. Fermi, 45, I-00044 Frascati, Roma (Italy); Marocco, D.; Villari, R. [Associazione Euratom-ENEA sulla Fusione, Via E. Fermi, 45, I-00044 Frascati, Roma (Italy); Murtas, F. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare, Via E. Fermi, 40, I-00044 Frascati, Roma (Italy); Rodionov, R. [SRC RF TRINITI Troitsk, Moscow (Russian Federation)

    2014-03-21

    The neutron efficiency of a Gas Electron Multiplier (GEM)-based detector designed for fast neutron measurements in fusion devices was determined through the combined use of Monte Carlo (MCNPX) calculations and analysis of deuterium–deuterium and deuterium–tritium neutron irradiation experiments. The detector, characterized by a triple GEM structure flushed with a Ar/CO{sub 2}/CF{sub 4} – 45/15/40 gas mixture, features a digital read-out system and has two sub-units for the detection of 2.5+14 MeV neutrons and 14 MeV neutrons (U{sub DD} and U{sub DT}, respectively). The pulse height spectra (PHS) determined from the curves of experimental efficiency as a function of the detector's high voltage (HV) and the MCNPX-simulated PHS were compared using a fitting routine that finds the best match between the experimental and simulated PHS by assuming a parametric model for the relation between HV (that determines the detector's gain) and the energy deposited in the gas. This led to express the experimental neutron efficiency as a function of the discrimination level set on the deposited energy (energy threshold). The detector sensitivity to γ-rays was also analyzed and the operational range in which the γ-ray contribution to the signal is not negligible was determined. It is found that this detector can reach a maximum neutron efficiency of ∼1×10{sup −3} counts/n at 2.5 MeV (U{sub DD} sub-unit) and of ∼4×10{sup −3} counts/n at 14 MeV (U{sub DT} and U{sub DD} sub-units)

  3. Comparison of fast neutron rates for the NEOS experiment

    Science.gov (United States)

    Ko, Y. J.; Jang, C. H.; Siyeon, Kim; Kim, J. Y.; Kim, H. S.; Seo, K. M.; Han, B. Y.; Sun, G. M.; Jeon, E. J.; Lee, Jaison; Lee, M. H.; Oh, Y. M.; Park, K. S.; Joo, K. K.; Kim, B. R.; Kim, H. J.; Lee, J. Y.; Kim, Y. D.; Park, H. K.; Park, H. S.

    2016-12-01

    The fast neutron rates are compared at the site of the NEOS (Neutrino Experiment Oscillation Short baseline) experiment, a short-baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and -off periods, and the fast neutron rates are found to be consistent with each other. The fast neutron rate is also measured at an overground site with a negligible overburden and is found to be 100 times higher than that at the site of the NEOS experiment.

  4. Research of Fast Neutron Radiation Effect on Rats

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In order to research the fast neutron radiation effect on rats,the 8 weeks Wistar male rats were wholly irradiated by 14 MeV fast neutron with 5 Gy. In the experiment,the rats were divided into normal and irradiation group, and killed

  5. Current Amplification Characteristics of BJT on Fast Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sung Ho; Sun, Gwang Min; Baek, Hani [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    BJT (Bipolar Junction Transistor) is a three-terminal device with an important feature in that the current through two terminals can be controlled by small changes we make in the current or voltage at the third terminal. This control feature allows us to amplify small AC signals or to switch the device from an on state and off state and back. Fast neutron irradiation incurs lattice damage in bulk Si. The recombination rate of minority carriers and register are increased by the lattice damage. This study will investigate the current amplification characteristics of a pnp Si BJT through fast neutron irradiation experiments. In this paper, the current amplification characteristics of a pnp Si BJT were investigated for fast neutron irradiation. The experimental results show that base-tocollector current amplification ratio is decreased with an increase in the fast neutron irradiation. These indicate that the lattice damage caused by fast neutron irradiation increases the recombination rate of minority carriers and resistor.

  6. High-Resolution Fast-Neutron Spectrometry for Arms Control and Treaty Verification

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; James T. Johnson; Edward H. Seabury

    2012-07-01

    Many nondestructive nuclear analysis techniques have been developed to support the measurement needs of arms control and treaty verification, including gross photon and neutron counting, low- and high-resolution gamma spectrometry, time-correlated neutron measurements, and photon and neutron imaging. One notable measurement technique that has not been extensively studied to date for these applications is high-resolution fast-neutron spectrometry (HRFNS). Applied for arms control and treaty verification, HRFNS has the potential to serve as a complimentary measurement approach to these other techniques by providing a means to either qualitatively or quantitatively determine the composition and thickness of non-nuclear materials surrounding neutron-emitting materials. The technique uses the normally-occurring neutrons present in arms control and treaty verification objects of interest as an internal source of neutrons for performing active-interrogation transmission measurements. Most low-Z nuclei of interest for arms control and treaty verification, including 9Be, 12C, 14N, and 16O, possess fast-neutron resonance features in their absorption cross sections in the 0.5- to 5-MeV energy range. Measuring the selective removal of source neutrons over this energy range, assuming for example a fission-spectrum starting distribution, may be used to estimate the stoichiometric composition of intervening materials between the neutron source and detector. At a simpler level, determination of the emitted fast-neutron spectrum may be used for fingerprinting 'known' assemblies for later use in template-matching tests. As with photon spectrometry, automated analysis of fast-neutron spectra may be performed to support decision making and reporting systems protected behind information barriers. This paper will report recent work at Idaho National Laboratory to explore the feasibility of using HRFNS for arms control and treaty verification applications, including simulations

  7. Characterization methods for an accelerator based fast-neutron facility

    Science.gov (United States)

    Franklyn, C.; Daniels, G. C.

    2012-02-01

    A fast neutron facility provides a number of complexities in both detection and shielding, the latter arising not only due to uncertainty in the behaviour of the scattered radiation (neutron and gamma-rays) from a fast neutron source, but also on shielding requirements that have to take into account internal and external factors, such as dose limitations, space availability for implementing bulky shielding and secondary interactions of the radiation with materials. This has possible influence on experimental measurements with a low signal to noise ratio. This paper reports on some of the investigations performed at a RFQ accelerator facility generating > 1011 neutrons per second with energies up to 14 MeV, which are used to perform fast neutron radiography studies. Areas highlighted are the neutron cross section libraries, where important data needs to be reviewed or updated.

  8. Ionizing Energy Depositions After Fast Neutron Interactions in Silicon

    CERN Document Server

    Bergmann, Benedikt; Caicedo, Ivan; Kierstead, James; Takai, Helio; Frojdh, Erik

    2016-01-01

    In this study we present the ionizing energy depositions in a 300 μm thick silicon layer after fast neutron impact. With the Time-of-Flight (ToF) technique, the ionizing energy deposition spectra of recoil silicons and secondary charged particles were assigned to (quasi-)monoenergetic neutron energies in the range from 180 keV to hundreds of MeV. We show and interpret representative measured energy spectra. By separating the ionizing energy losses of the recoil silicon from energy depositions by products of nuclear reactions, the competition of ionizing (IEL) and non-ionizing energy losses (NIEL) of a recoil silicon within the silicon lattice was investigated. The data give supplementary information to the results of a previous measurement and are compared with different theoretical predictions.

  9. Spectrometry and dosimetry of fast neutrons using pin diode detectors

    Energy Technology Data Exchange (ETDEWEB)

    Zaki Dizaji, H., E-mail: hz.dizaji@znu.ac.ir [Physics Department, Faculty of Science, Zanjan University, Zanjan (Iran, Islamic Republic of); Kakavand, T. [Physics Department, Faculty of Science, International Imam Khomeini University, Qazvin (Iran, Islamic Republic of); Abbasi Davani, F. [Radiation Application Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of)

    2014-03-21

    Elastic scattering of light nuclei, especially hydrogen, is widely used for detection of fast neutrons. Semiconductor devices based on silicon detectors are frequently used for different radiation detections. In this work, a neutron spectrometer consisting of a pin diode coupled with a polyethylene converter and aluminum degrader layers has been developed. Aluminum layers are used as discriminators of different neutron energies for detectors. The response of the converter–degrader–pin diode configuration, the optimum thickness of the converter and the degrader layers have been extracted using MCNP and SRIM simulation codes. The possibility of using this type of detector for fast neutron spectrometry and dosimetry has been investigated. A fairly good agreement was seen between neutron energy spectrum and dose obtained from our configurations and these specifications from an {sup 241}Am–Be neutron source. - Highlights: • Silicon pin diodes are applied to the fast neutron detection. • The technique of converter degrader pin diode is used for spectrometry of fast neutrons. • The method is used for dosimetry of fast neutron.

  10. Development and characterization of a high sensitivity segmented Fast Neutron Spectrometer (FaNS-2)

    Science.gov (United States)

    Langford, T. J.; Beise, E. J.; Breuer, H.; Heimbach, C. R.; Ji, G.; Nico, J. S.

    2016-01-01

    We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and 3He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a 3He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron fluxes. A main goal of its design is to study comparatively low neutron fluxes, such as cosmogenic neutrons at the Earth's surface, in an underground environment, or from low-activity neutron sources. In this paper, we present details of its design and construction as well as its characterization with a calibrated 252Cf source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected monoenergetic neutron spectra are unfolded using a Singular Value Decomposition method, demonstrating a 5% energy resolution at 14 MeV. Finally, we discuss plans for measuring the surface and underground cosmogenic neutron spectra with FaNS-2.

  11. C7LYC Scintillators and Fast Neutron Spectroscopy

    Science.gov (United States)

    Chowdhury, P.; Brown, T.; Doucet, E.; Lister, C. J.; Wilson, G. L.; D'Olympia, N.; Devlin, M.; Mosby, S.

    2016-09-01

    Cs2 LiYCl6 (CLYC) scintillators detect both gammas and neutrons with excellent pulse shape discrimination. At UML, fast neutron measurements with a 16-element 1''x1'' CLYC array show promise for low energy nuclear science. CLYC detects fast neutrons via the 35Cl (n,p) reaction (resolution UML. Results will be discussed in the context of constructing a C7LYC array at FRIB for reaction and decay spectroscopy of neutron-rich fragments. Supported by the NNSA Stewardship Science Academic Alliance Program under Grant DE-NA00013008.

  12. Fast neutron activation analysis by means of low voltage neutron generator

    Science.gov (United States)

    Medhat, M. E.

    A description of D-T neutron generator (NG) is presented. This machine can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. Procedure of neutron flux determination and efficiency calculation is described. Examples of testing some Egyptian natural cosmetics are given.

  13. Fast neutrons set the pace. [Radiobiological investigations with fast neutrons at the CSIR cyclotron in Pretoria

    Energy Technology Data Exchange (ETDEWEB)

    Hough, J.H.; Slabbert, J.P. (Council for Scientific and Industrial Research, Pretoria (South Africa). National Accelerator Centre)

    1985-01-01

    Radiobiological investigations with fast neutrons have been initiated at the CSIR cyclotron in Pretoria. It was proposed some years ago to create a neutron therapy facility using the CSIR cyclotron. Neutrons are classified as high linear energy transfer (LET) particles. Biological damage occurring in tissue is a direct function of the LET of the incident radiation. To quantify the biological effects of different types of radiation on mammalian cells, several procedures and concepts have evolved from radiobiological research. Probably the most significant laboratory techniques developed, were the derivation of cell survival curves which are obtained by determining the number of cell colonies that have survived a certain radiation dose. A semi-logarithmic plot of surviving fraction versus the absorbed dose yields the survival curve. Dose modifying factors such as the relative biological effectiveness (RBE) of the radiation can be quantified in terms of this relationship. A radiobiological programme has to be undertaken before patients can receive neutron therapy at the CSIR cyclotron. The article is a discussion of this programme.

  14. Monte Carlo Calculations for Neutron and Gamma Radiation Fields on a Fast Neutron Irradiation Device

    Science.gov (United States)

    Vieira, A.; Ramalho, A.; Gonçalves, I. C.; Fernandes, A.; Barradas, N.; Marques, J. G.; Prata, J.; Chaussy, Ch.

    We used the Monte Carlo program MCNP to calculate the neutron and gamma fluxes on a fast neutron irradiation facility being installed on the Portuguese Research Reactor (RPI). The purpose of this facility is to provide a fast neutron beam for irradiation of electronic circuits. The gamma dose should be minimized. This is achieved by placing a lead shield preceded by a thin layer of boral. A fast neutron flux of the order of 109 n/cm2s is expected at the exit of the tube, while the gamma radiation is kept below 20 Gy/h. We will present results of the neutron and gamma doses for several locations along the tube and different thickness of the lead shield. We found that the neutron beam is very collimated at the end of the tube with a dominant component on the fast region.

  15. Study on fast neutron dosimetry using electrochemical etching

    Energy Technology Data Exchange (ETDEWEB)

    Lin, J.T. (National Tsing-Hua Univ., Hsin-Chu, Taiwan); Su, S.J.

    1981-03-01

    Registration of fast-neutron-induced-recoil tracks by electrochemical etching technique as applied to polycarbonate foils has provided a simple, sensitive, and inexpensive means of fast neutron personnel dosimetry. Etching parameters are carefully discussed and it was discovered a new method of stirring in KOH aqueous solution offered considerable improvement over previous procedures. Applied frequency can be decreased from 2kHz to regular 60Hz. The sensitivity of fast neutrons is 0.12-0.18 tracks/cm/sup 2/ per mrem with standard deviation of +/- 20.2%.

  16. The Use of Fast Neutron Detection for Materials Accountability

    Science.gov (United States)

    Nakae, L. F.; Chapline, G. F.; Glenn, A. M.; Kerr, P. L.; Kim, K. S.; Ouedraogo, S. A.; Prasad, M. K.; Sheets, S. A.; Snyderman, N. J.; Verbeke, J. M.; Wurtz, R. E.

    2014-02-01

    For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) inherent in man-portable systems. Historically, thermal neutron detectors (mainly 3He) were used, taking advantage of the high thermal neutron interaction cross-sections, but more recently we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production timescales of fission and neutron-induced fission are preserved and measured instead of being lost in the thermalization of thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of high efficiency counters. Faster detector response times and sensitivity to neutron momentum show promise in measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed neutron sources (e.g., Pu oxide or Mixed Cm and Pu). Here we report on measured results with our existing liquid scintillator array and promote the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator becomes competitive and even surpasses the precision of 3He counters measuring correlated pairs in modest (kg) samples of plutonium.

  17. Development of fast neutron radiography system based on portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Chia Jia, E-mail: gei-i-kani@hotmail.com; Nilsuwankosit, Sunchai, E-mail: sunchai.n@chula.ac.th [Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Phayathai Rd., Patumwan, Bangkok, THAILAND 10330 (Thailand)

    2016-01-22

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

  18. Development of fast neutron radiography system based on portable neutron generator

    Science.gov (United States)

    Yi, Chia Jia; Nilsuwankosit, Sunchai

    2016-01-01

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

  19. Ionization signals from diamond detectors in fast-neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); CIVIDEC Instrumentation, Wien (Austria); Frais-Koelbl, H. [University of Applied Sciences, Wiener Neustadt (Austria); Griesmayer, E.; Kavrigin, P. [CIVIDEC Instrumentation, Wien (Austria); Vienna University of Technology, Wien (Austria)

    2016-09-15

    In this paper we introduce a novel analysis technique for measurements with single-crystal chemical vapor deposition (sCVD) diamond detectors in fast-neutron fields. This method exploits the unique electronic property of sCVD diamond sensors that the signal shape of the detector current is directly proportional to the initial ionization profile. In fast-neutron fields the diamond sensor acts simultaneously as target and sensor. The interaction of neutrons with the stable isotopes {sup 12}C and {sup 13}C is of interest for fast-neutron diagnostics. The measured signal shapes of detector current pulses are used to identify individual types of interactions in the diamond with the goal to select neutron-induced reactions in the diamond and to suppress neutron-induced background reactions as well as γ-background. The method is verified with experimental data from a measurement in a 14.3 MeV neutron beam at JRC-IRMM, Geel/Belgium, where the {sup 13}C(n, α){sup 10}Be reaction was successfully extracted from the dominating background of recoil protons and γ-rays and the energy resolution of the {sup 12}C(n, α){sup 9}Be reaction was substantially improved. The presented analysis technique is especially relevant for diagnostics in harsh radiation environments, like fission and fusion reactors. It allows to extract the neutron spectrum from the background, and is particularly applicable to neutron flux monitoring and neutron spectroscopy. (orig.)

  20. Ionization signals from diamond detectors in fast-neutron fields

    Science.gov (United States)

    Weiss, C.; Frais-Kölbl, H.; Griesmayer, E.; Kavrigin, P.

    2016-09-01

    In this paper we introduce a novel analysis technique for measurements with single-crystal chemical vapor deposition (sCVD) diamond detectors in fast-neutron fields. This method exploits the unique electronic property of sCVD diamond sensors that the signal shape of the detector current is directly proportional to the initial ionization profile. In fast-neutron fields the diamond sensor acts simultaneously as target and sensor. The interaction of neutrons with the stable isotopes 12 C and 13 C is of interest for fast-neutron diagnostics. The measured signal shapes of detector current pulses are used to identify individual types of interactions in the diamond with the goal to select neutron-induced reactions in the diamond and to suppress neutron-induced background reactions as well as γ-background. The method is verified with experimental data from a measurement in a 14.3 MeV neutron beam at JRC-IRMM, Geel/Belgium, where the 13C(n, α)10Be reaction was successfully extracted from the dominating background of recoil protons and γ-rays and the energy resolution of the 12C(n, α)9Be reaction was substantially improved. The presented analysis technique is especially relevant for diagnostics in harsh radiation environments, like fission and fusion reactors. It allows to extract the neutron spectrum from the background, and is particularly applicable to neutron flux monitoring and neutron spectroscopy.

  1. Development and Characterization of a High Sensitivity Segmented Fast Neutron Spectrometer (FaNS-2)

    CERN Document Server

    Langford, T J; Breuer, H; Heimbach, C R; Ji, G; Nico, J S

    2015-01-01

    We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a $^3$He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron fluxes. A main goal of its design is to study comparatively low neutron fluxes, such as cosmogenic neutrons at the Earth's surface, in an underground environment, or from low-activity neutron sources. In this paper, we present details of its design and construction as well as its characterization with a calibrated $^{252}$Cf source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected monoenergetic neutron spectra...

  2. Spectral unfolding of fast neutron energy distributions

    Science.gov (United States)

    Mosby, Michelle; Jackman, Kevin; Engle, Jonathan

    2015-10-01

    The characterization of the energy distribution of a neutron flux is difficult in experiments with constrained geometry where techniques such as time of flight cannot be used to resolve the distribution. The measurement of neutron fluxes in reactors, which often present similar challenges, has been accomplished using radioactivation foils as an indirect probe. Spectral unfolding codes use statistical methods to adjust MCNP predictions of neutron energy distributions using quantified radioactive residuals produced in these foils. We have applied a modification of this established neutron flux characterization technique to experimentally characterize the neutron flux in the critical assemblies at the Nevada National Security Site (NNSS) and the spallation neutron flux at the Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL). Results of the unfolding procedure are presented and compared with a priori MCNP predictions, and the implications for measurements using the neutron fluxes at these facilities are discussed.

  3. Measurement of the Surface and Underground Neutron Spectra with the UMD/NIST Fast Neutron Spectrometers

    Science.gov (United States)

    Langford, Thomas J.

    The typical fast neutron detector falls into one of two categories, Bonner sphere spectrometers and liquid scintillator proton recoil detectors. These two detector types have traditionally been used to measure fast neutrons at the surface and in low background environments. The cosmogenic neutron spectrum and flux is an important parameter for a number of experimental efforts, including procurement of low background materials and the prediction of electronic device faults. Fast neutrons can also cause problems for underground low-background experiments, through material activation or signals that mimic rare events. Current detector technology is not sufficient to properly characterize these backgrounds. To this end, the University of Maryland and the National Institute of Standards and Technology designed, developed, and deployed two Fast Neutron Spectrometers (FaNS) comprised of plastic scintillator and 3He proportional counters. The detectors are based upon capture-gated spectroscopy, a technique that demands a delayed coincidence between a neutron scatter and the resulting neutron capture after thermalization. This technique provides both particle identification and knowledge that the detected neutron fully thermalized. This improves background rejection capabilities and energy resolution. Presented are the design, development, and deployment of FaNS-1 and FaNS-2. Both detectors were characterized using standard fields at NIST, including calibrated 252Cf neutron sources and two monoenergetic neutron generators. Measurements of the surface fast neutron spectrum and flux have been made with both detectors, which are compared with previous measurements by traditional detectors. Additionally, FaNS-1 was deployed at the Kimballton Underground Research Facility (KURF) in Ripplemead, VA. A measurement of the fast neutron spectrum and flux at KURF is presented as well. FaNS-2 is currently installed in a shallow underground laboratory where it is measuring the muon

  4. Improvement of Neutronics Calculation Methods for Fast Reactors

    OpenAIRE

    Takeda, Toshikazu

    2011-01-01

    To accurately estimate neutronics properties of fast reactors, particularly Japan Sodium-cooled Fast Reactor of1,500 MW electric, calculational methods are being improved in Japan.This paper describes the planning and the ongoing development of the neutronics calculation methods in the fieldof 1) assembly calculations including the calculations of effective cross sections, 2) core calculations and 3) uncertaintyevaluation and uncertainty reduction.

  5. Chemical weapons detection by fast neutron activation analysis techniques

    Science.gov (United States)

    Bach, P.; Ma, J. L.; Froment, D.; Jaureguy, J. C.

    1993-06-01

    A neutron diagnostic experimental apparatus has been tested for nondestructive verification of sealed munitions. Designed to potentially satisfy a significant number of van-mobile requirements, this equipment is based on an easy to use industrial sealed tube neutron generator that interrogates the munitions of interest with 14 MeV neutrons. Gamma ray spectra are detected with a high purity germanium detector, especially shielded from neutrons and gamma ray background. A mobile shell holder has been used. Possible configurations allow the detection, in continuous or in pulsed modes, of gamma rays from neutron inelastic scattering, from thermal neutron capture, and from fast or thermal neutron activation. Tests on full scale sealed munitions with chemical simulants show that those with chlorine (old generation materials) are detectable in a few minutes, and those including phosphorus (new generation materials) in nearly the same time.

  6. Feasibility study of fast neutron energy spectrometer using magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, Hideshi; Ara, Katsuyuki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-09-01

    A feasibility study of a fast neutron energy spectrometer (NES) using magnetic field was performed for development of a spectrometer having a measuring range of 3 decades and a covered energy range of 8 decades. The NES that is a kind of proton recoil spectrometer consists of a proton radiator, a magnet and a screen to detect protons. The pass of each charge particle flying into the magnetic field is deflected with a certain angle depending on the velocity of the particle, and it reaches the screen of charged particle detection after passing through the magnetic field. The energy of the particle is measured from the position on the screen at which the particle collide with. In this paper, optimization of the magnet geometry and the magnetic field intensity of the NES are discussed. The NES that is designed with the optimized geometry provides the measuring range of 3 decades with an energy measuring error of less than {+-}9%. A neutron energy range of 9 decades from 0.1 (eV) to 100 (MeV) is covered by adjusting the magnetic flux density. (author)

  7. Measurement of Fast Neutron Rate for NEOS Experiment

    CERN Document Server

    Ko, Y J; Han, B Y; Jang, C H; Jeon, E J; Joo, K K; Kim, B R; Kim, H J; Kim, H S; Kim, Y D; Lee, Jaison; Lee, J Y; Lee, M H; Oh, Y M; Park, H K; Park, H S; Park, K S; Seo, K M; Siyeon, Kim; Sun, G M

    2016-01-01

    The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day for both periods. The fast neutron rate is also measured at an overground site with a negligible overburden and is found to be ~100 times higher than that at the NEOS experiment site.

  8. Final Report on Actinide Glass Scintillators for Fast Neutron Detection

    Energy Technology Data Exchange (ETDEWEB)

    Bliss, Mary; Stave, Jean A.

    2012-10-01

    This is the final report of an experimental investigation of actinide glass scintillators for fast-neutron detection. It covers work performed during FY2012. This supplements a previous report, PNNL-20854 “Initial Characterization of Thorium-loaded Glasses for Fast Neutron Detection” (October 2011). The work in FY2012 was done with funding remaining from FY2011. As noted in PNNL-20854, the glasses tested prior to July 2011 were erroneously identified as scintillators. The decision was then made to start from “scratch” with a literature survey and some test melts with a non-radioactive glass composition that could later be fabricated with select actinides, most likely thorium. The normal stand-in for thorium in radioactive waste glasses is cerium in the same oxidation state. Since cerium in the 3+ state is used as the light emitter in many scintillating glasses, the next most common substitute was used: hafnium. Three hafnium glasses were melted. Two melts were colored amber and a third was clear. It barely scintillated when exposed to alpha particles. The uses and applications for a scintillating fast neutron detector are important enough that the search for such a material should not be totally abandoned. This current effort focused on actinides that have very high neutron capture energy releases but low neutron capture cross sections. This results in very long counting times and poor signal to noise when working with sealed sources. These materials are best for high flux applications and access to neutron generators or reactors would enable better test scenarios. The total energy of the neutron capture reaction is not the only factor to focus on in isotope selection. Many neutron capture reactions result in energetic gamma rays that require large volumes or high densities to detect. If the scintillator is to separate neutrons from gamma rays, the capture reactions should produce heavy particles and few gamma rays. This would improve the detection of a

  9. Neutron intensity of fast reactor spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Takamatsu, Misao; Aoyama, Takafumi [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-03-01

    Neutron intensity of spent fuel of the JOYO Mk-II core with a burnup of 62,500 MWd/t and cooling time of 5.2 years was measured at the spent fuel storage pond. The measured data were compared with the calculated values based on the JOYO core management code system `MAGI`, and the average C/E approximately 1.2 was obtained. It was found that the axial neutron intensity didn`t simply follow the burnup distribution, and the neutron intensity was locally increased at the bottom end of the fuel region due to an accumulation of {sup 244}Cm. (author)

  10. System design considerations for fast-neutron interrogation systems

    Energy Technology Data Exchange (ETDEWEB)

    Micklich, B.J.; Curry, B.P.; Fink, C.L.; Smith, D.L.; Yule, T.J.

    1993-10-01

    Nonintrusive interrogation techniques that employ fast neutrons are of interest because of their sensitivity to light elements such as carbon, nitrogen, and oxygen. The primary requirement of a fast-neutron inspection system is to determine the value of atomic densities, or their ratios, over a volumetric grid superimposed on the object being interrogated. There are a wide variety of fast-neutron techniques that can provide this information. The differences between the various nuclear systems can be considered in light of the trade-offs relative to the performance requirements for each system`s components. Given a set of performance criteria, the operational requirements of the proposed nuclear systems may also differ. For instance, resolution standards will drive scanning times and tomographic requirements, both of which vary for the different approaches. We are modelling a number of the fast-neutron interrogation techniques currently under consideration, to include Fast Neutron Transmission Spectroscopy (FNTS), Pulsed Fast Neutron Analysis (PFNA), and its variant, 14-MeV Associated Particle Imaging (API). The goals of this effort are to determine the component requirements for each technique, identify trade-offs that system performance standards impose upon those component requirements, and assess the relative advantages and disadvantages of the different approaches. In determining the component requirements, we will consider how they are driven by system performance standards, such as image resolution, scanning time, and statistical uncertainty. In considering the trade-offs between system components, we concentrate primarily on those which are common to all approaches, for example: source characteristics versus detector array requirements. We will then use the analysis to propose some figures-of-merit that enable performance comparisons between the various fast-neutron systems under consideration. The status of this ongoing effort is presented.

  11. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    DESIG: E 263 09 ^TITLE: Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron ^SIGNUSE: Refer to Guide E 844 for guidance on the selection, irradiation, and quality control of neutron dosimeters. Refer to Practice E 261 for a general discussion of the determination of fast-neutron fluence rate with threshold detectors. Pure iron in the form of foil or wire is readily available and easily handled. Fig. 1 shows a plot of cross section as a function of neutron energy for the fast-neutron reaction 54Fe(n,p)54Mn (1). This figure is for illustrative purposes only to indicate the range of response of the 54Fe(n,p)54Mn reaction. Refer to Guide E 1018 for descriptions of recommended tabulated dosimetry cross sections. 54Mn has a half-life of 312.13 days (3) (2) and emits a gamma ray with an energy of 834.845 keV (5). (2) Interfering activities generated by neutron activation arising from thermal or fast neutron interactions are 2.57878 (46)-h 56Mn, 44.95-d (8) 59Fe, and 5.27...

  12. Effect of Gamma Rays on Fast Neutron Registration in CR-39

    CERN Document Server

    Kobzev, A P; El-Halem, A A; Abdul-Ghaphar, U S; Salama, T A

    2002-01-01

    A set of CR-39 plastic detectors with front PE radiator was exposed to Am-Be neutron source, which has an emission rate of 0.86\\cdot 10^{7} sec^{-1}, and the neutron dose equivalent rate 1 m apart from the source is equal to 11 mrem/hr. Another set of samples was irradiated by a neutron dose of 4 rem, then exposed to different gamma-ray doses using ^{60}Co source. It was found that the track density grows with the increase of neutron dose and etching time. It was also found that the bulk etching rate V_{B}, the track diameter and the sensitivity of the CR-39 plastic detector with respect to the neutron irradiation increased with increasing gamma-ray dose in the range 1?10 Mrad. These results show that CR-39 can be considered as a promising fast neutron dosimeter and gamma-ray dosimeter.

  13. Transport simulation and image reconstruction for fast-neutron detection of explosives and narcotics

    Energy Technology Data Exchange (ETDEWEB)

    Micklich, B.J.; Fink, C.L.; Sagalovsky, L.

    1995-07-01

    Fast-neutron inspection techniques show considerable promise for explosive and narcotics detection. A key advantage of using fast neutrons is their sensitivity to low-Z elements (carbon, nitrogen, and oxygen), which are the primary constituents of these materials. We are currently investigating two interrogation methods in detail: Fast-Neutron Transmission Spectroscopy (FNTS) and Pulsed Fast-Neutron Analysis (PFNA). FNTS is being studied for explosives and narcotics detection in luggage and small containers for which the transmission ratio is greater than about 0.01. The Monte-Carlo radiation transport code MCNP is being used to simulate neutron transmission through a series of phantoms for a few (3-5) projection angles and modest (2 cm) resolution. Areal densities along projection rays are unfolded from the transmission data. Elemental abundances are obtained for individual voxels by tomographic reconstruction, and these reconstructed elemental images are combined to provide indications of the presence or absence of explosives or narcotics. PFNA techniques are being investigated for detection of narcotics in cargo containers because of the good penetration of the fast neutrons and the low attenuation of the resulting high-energy gamma-ray signatures. Analytic models and Monte-Carlo simulations are being used to explore the range of capabilities of PFNA techniques and to provide insight into systems engineering issues. Results of studies from both FNTS and PFNA techniques are presented.

  14. Lithium-containing scintillators for thermal neutron, fast neutron, and gamma detection

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia P.; Carman, M. Leslie; Faust, Michelle A.

    2016-03-01

    In one embodiment, a scintillator includes a scintillator material; a primary fluor, and a Li-containing compound, where the Li-containing compound is soluble in the primary fluor, and where the scintillator exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays.

  15. A Capture-gated Fast Neutron Detection Method

    CERN Document Server

    Liu, Yi; Tai, Yang; Zhang, Zhi

    2016-01-01

    To address the problem of the shortage of neutron detectors used in radiation portal monitors (RPMs), caused by the 3He supply crisis, research on a cadmium-based capture-gated fast neutron detector is presented in this paper. The detector is composed of many 1 cm * 1 cm * 20 cm plastic scintillator cuboids covered by 0.1 mm thick film of cadmium. The detector uses cadmium to absorb thermal neutrons and produce capture gamma-rays to indicate the detection of neutrons, and uses plastic scintillator to moderate neutrons and register gamma-rays. This design removes the volume competing relationship in traditional 3He counter-based fast neutron detectors, which hinders enhancement of the neutron detection efficiency. Detection efficiency of 21.66 +- 1.22% has been achieved with a 40.4 cm * 40.4 cm * 20 cm overall detector volume. This detector can measure both neutrons and gamma-rays simultaneously. A small detector (20.2 cm * 20.2 cm * 20 cm) demonstrated a 3.3 % false alarm rate for a 252Cf source with a neutro...

  16. Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT).

    Science.gov (United States)

    Cecilia, A; Baccaro, S; Cemmi, A; Colli, V; Gambarini, G; Rosi, G; Scolari, L

    2004-01-01

    A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF2:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH3CH(NH2)COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT.

  17. Digital Acquisition Development for Fast Neutron Detectors

    Science.gov (United States)

    Seagren, T.; Mosby, S.; Mona Collaboration; Lansce P-27 Team

    2015-10-01

    The use of the Modular Neutron Array (MoNA) at FRIB requires a thorough understanding of how neutrons propagate through the array. This leads to the increasing importance of accuracy in detector response simulations, particularly in the case of FRIB's higher beam energies. An upcoming experiment at the LANSCE facility at Los Alamos National Lab will benchmark neutron propagation through the MoNA array and provide a more complete validation of the simulation software. LANSCE also hosts the Chi-Nu experiment, which seeks to measure fission output neutrons using the high-intensity neutron beams there. In both experiments, the instantaneous rate on the detectors involved is expected to be very high, due to the LANSCE/WNR beam structure. Therefore, waveform digitizers with on-board processing are required in order for the experiments to succeed. These digitizers provide on-board timing algorithms using FPGA firmware, and several tests were preformed in order to determine what the optimal timing filter settings were for a variety of detectors, including the plastic and liquid scintillators to be used in MoNA and Chi-Nu respectively. This work will inform the execution of the MoNA and Chi-Nu experiments at LANSCE. The details of the methods used and results will be presented. Supported by funding through Los Alamos National Lab and NSF Grant PHY-1506402.

  18. A fast and flexible reactor physics model for simulating neutron spectra and depletion in fast reactors

    Science.gov (United States)

    Recktenwald, Geoff; Deinert, Mark

    2010-03-01

    Determining the time dependent concentration of isotopes within a nuclear reactor core is central to the analysis of nuclear fuel cycles. We present a fast, flexible tool for determining the time dependent neutron spectrum within fast reactors. The code (VBUDS: visualization, burnup, depletion and spectra) uses a two region, multigroup collision probability model to simulate the energy dependent neutron flux and tracks the buildup and burnout of 24 actinides, as well as fission products. While originally developed for LWR simulations, the model is shown to produce fast reactor spectra that show high degree of fidelity to available fast reactor benchmarks.

  19. An empirical formula for scattered neutron components in fast neutron radiography

    Institute of Scientific and Technical Information of China (English)

    DOU Hai-Feng; TANG Bin

    2011-01-01

    Scattering neutrons are one of the key factors that may affect the images of fast neutron radiog- raphy. In this paper, a mathematical model for scattered neutrons is developed on a cylinder sample, and an empirical formula for scattered neutrons is obtained. According to the results given by Monte Carlo methods, the parameters in the empirical formula are obtained with curve fitting, which confirms the logicality of the empirical formula. The curve-fitted parameters of common materials such as LiD are given.

  20. Development and performance of the Fast Neutron Imaging Telescope for SNM detection

    Science.gov (United States)

    Ryan, James M.; Bravar, Ulisse; Flückiger, Erwin O.; Macri, John R.; McConnell, Mark L.; Pirard, Benoit; Woolf, Richard S.

    2008-04-01

    FNIT (the Fast Neutron Imaging Telescope), a detector with both imaging and energy measurement capabilities, sensitive to neutrons in the range 0.8-20 MeV, was initially conceived to study solar neutrons as a candidate design for the Inner Heliosphere Sentinel (IHS) spacecraft of NASA's Solar Sentinels program and successively reconfigured to locate fission neutron sources. By accurately identifying the position of the source with imaging techniques and reconstructing the Watt spectrum of fission neutrons, FNIT can detect samples of special nuclear material (SNM), including heavily shielded and masked ones. The detection principle is based on multiple elastic neutron-proton scatterings in organic scintillators. By reconstructing n-p event locations and sequence and measuring the recoil proton energies, the direction and energy spectrum of the primary neutron flux can be determined and neutron sources identified. We describe the design of the FNIT prototype and present its energy reconstruction and imaging performance, assessed by exposing FNIT to a neutron beam and to a Pu fission neutron source.

  1. Fast neutron measurements at the nELBE time-of-flight facility

    Directory of Open Access Journals (Sweden)

    Junghansa A. R.

    2015-01-01

    Full Text Available The compact neutron-time-of-flight facility nELBE at the superconducting electron accelerator ELBE of Helmholtz-Zentrum Dresden-Rossendorf has been rebuilt. A new enlarged experimental hall with a flight path of up to 10 m is available for neutron time-of-flight experiments in the fast energy range from about 50 keV to 10 MeV. nELBE is intended to deliver nuclear data of fast neutron nuclear interactions e.g. for the transmutation of nuclear waste and improvement of neutron physical simulations of innovative nuclear systems. The experimental programme consists of transmission measurements of neutron total cross sections, elastic and inelastic scattering cross section measurements, and neutron induced fission cross sections. The inelastic scattering to the first few excited states in 56Fe was investigated by measuring the gamma production cross section with an HPGe detector. The neutron induced fission of 242Pu was studied using fast ionisation chambers with large homogeneous actinide deposits.

  2. [Fast neutrons in the treatment of soft tissue sarcomas].

    Science.gov (United States)

    Chernichenko, V A; Tolstopiatov, B A; Monich, A Iu; Konovalenko, V F; Galakhin, K A; Palivets, A Iu; Vorona, A M

    1990-01-01

    Results of treatment of 101 cases of soft tissue sarcoma are presented in the paper. Preoperative irradiation technique and radical program of treatment are described. Combined radiation and surgical treatment was given to 45 patients whereas conservative--to 56. Sixty-three cases received adjuvant combination chemotherapy. Response and three-year survival rates were compared to those in control group treated by photons. The results observed in patients of combined and conservative treatment groups who had been irradiated with fast neutrons proved significantly better than in controls. These data suggest vistas in application of fast neutron irradiation for the treatment of soft tissue sarcomas.

  3. FAST FOSSIL ROTATION OF NEUTRON STAR CORES

    Energy Technology Data Exchange (ETDEWEB)

    Melatos, A., E-mail: amelatos@unimelb.edu.au [School of Physics, University of Melbourne, Parkville, VIC 3010 (Australia)

    2012-12-10

    It is argued that the superfluid core of a neutron star super-rotates relative to the crust, because stratification prevents the core from responding to the electromagnetic braking torque, until the relevant dissipative (viscous or Eddington-Sweet) timescale, which can exceed {approx}10{sup 3} yr and is much longer than the Ekman timescale, has elapsed. Hence, in some young pulsars, the rotation of the core today is a fossil record of its rotation at birth, provided that magnetic crust-core coupling is inhibited, e.g., by buoyancy, field-line topology, or the presence of uncondensed neutral components in the superfluid. Persistent core super-rotation alters our picture of neutron stars in several ways, allowing for magnetic field generation by ongoing dynamo action and enhanced gravitational wave emission from hydrodynamic instabilities.

  4. Fast-neutron induced background in LaBr{sub 3}:Ce detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kiener, J., E-mail: Jurgen.Kiener@csnsm.in2p3.fr [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), CNRS-IN2P3 et Université Paris-Sud, 91405 Campus Orsay (France); Tatischeff, V.; Deloncle, I. [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), CNRS-IN2P3 et Université Paris-Sud, 91405 Campus Orsay (France); Séréville, N. de [Institut de Physique Nucléaire d' Orsay, CNRS-IN2P3 and Université Paris-Sud, 91406 Orsay (France); Laurent, P. [CEA/IRFU Service d' Astrophysique, Orme des Merisiers, CEA Saclay, 91191 Gif-sur-Yvette (France); Laboratoire Astroparticules et Cosmologie (APC), 10, rue A. Domon et L. Duquet, 75205 Paris (France); Blondel, C. [Laboratoire AIM, CEA/IRFU, Orme des Merisiers, CEA Saclay, 91191 Gif-sur-Yvette (France); Chabot, M. [Institut de Physique Nucléaire d' Orsay, CNRS-IN2P3 and Université Paris-Sud, 91406 Orsay (France); Chipaux, R. [CEA/DMS/IRFU/SEDI, CEA Saclay, 91191 Gif sur Yvette (France); Coc, A. [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), CNRS-IN2P3 et Université Paris-Sud, 91405 Campus Orsay (France); Dubos, S. [Laboratoire AIM, CEA/IRFU, Orme des Merisiers, CEA Saclay, 91191 Gif-sur-Yvette (France); Gostojic, A. [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), CNRS-IN2P3 et Université Paris-Sud, 91405 Campus Orsay (France); and others

    2015-10-21

    The response of a scintillation detector with a cylindrical 1.5-in. LaBr{sub 3}:Ce crystal to incident neutrons has been measured in the energy range E{sub n} = 2–12 MeV. Neutrons were produced by proton irradiation of a Li target at E{sub p} = 5–14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr{sub 3}:Ce detector resulting from fast neutron interactions have been obtained at 4 different neutron energies. Neutron-induced γ rays emitted by the LaBr{sub 3}:Ce crystal were also measured in a nearby Ge detector at the lowest proton beam energy. In addition, we obtained data for neutron irradiation of a large-volume high-purity Ge detector and of a NE-213 liquid scintillator detector, both serving as monitor detectors in the experiment. Monte-Carlo type simulations for neutron interactions in the liquid scintillator, the Ge and LaBr{sub 3}:Ce crystals have been performed and compared with measured data. Good agreement being obtained with the data, we present the results of simulations to predict the response of LaBr{sub 3}:Ce detectors for a range of crystal sizes to neutron irradiation in the energy range E{sub n} = 0.5–10 MeV.

  5. A wide-range direction neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Luszik-Bhadra, M. E-mail: marlies.luszik-bhadra@ptb.de; D' Errico, F.; Hecker, O.; Matzke, M

    2002-01-01

    A new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with different energy and direction distributions of neutron fluence. The direction-integrated fluence spectra agree fairly well with reference spectra. In all cases, the ambient and personal dose equivalent values calculated from measured direction-differential spectra are within 35% of the reference values. Independent measurements of the directional dose equivalent were performed with a directional dose equivalent monitor based on superheated drop detectors.

  6. Improved safety fast reactor with “reservoir” for delayed neutrons generating

    Science.gov (United States)

    Kulikov, G. G.; Apse, V. A.; Shmelev, A. N.; Kulikov, E. G.

    2017-01-01

    The paper considers the possibility to improve safety of fast reactors by using weak neutron absorber with large atomic weight as a material for external neutron reflector and for internal cavity in the reactor core (the neutron “reservoir”) where generation of some additional “delayed” neutron takes place. The effects produced by the external neutron reflector and the internal neutron “reservoir” on kinetic behavior of fast reactors are inter-compared. It is demonstrated that neutron kinetics of fast reactors with such external and internal zones becomes the quieter as compared with neutron kinetics of thermal reactors.

  7. FAST NEUTRON SOURCE DETECTION AT LONG DISTANCES USING DOUBLE SCATTER SPECTROMETRY.

    Energy Technology Data Exchange (ETDEWEB)

    FORMAN,L.VANIER,P.WELSH,K.

    2003-08-03

    Fast neutrons can be detected with relatively high efficiency, >15%, using two planes of hydrogenous scintillator detectors where a scatter in the first plane creates a start pulse and scatter in the second plane is separated by time-of-flight. Indeed, the neutron spectrum of the source can be determined as the sum of energy deposited by pulse height in the first added to the energy of the second found by time-of-flight to the second detector. Gamma rays can also create a double scatter by Compton interaction in the first with detection in the second, but these events occur in a single time window because the scattered photons all travel at the speed of light. Thus, gamma ray events can be separated from neutrons by the time-of-flight differences. We have studied this detection system with a Cf-252 source using Bicron 501A organic scintillators and report on the ability to efficiently detect fast neutrons with high neutron/gamma detection ratios. We have further studied cosmic-ray neutron background detection response that is the dominant background in long range detection. We have found that most of the neutrons are excluded from the time-of-flight window because they are either too high in energy, >10 keV, or too low, < 10 keV. Moreover, if the detection planes are position-sensitive, the angular direction of the source can be determined by the ratio of the energy of scattered protons in the first detector relative to the position and energy of the scattered neutron detected in the second. This ability to locate the source in theta is useful, but more importantly increases the signal to noise relative to cosmic-ray produced neutrons that are relatively isotropic. This technique may be used in large arrays to detect neutrons at ranges up to 0.5 kilometer.

  8. Spectroscopic study of fast-neutron-irradiated chromatin

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L. [V. Babes National Inst., Dept. of Molecular Genetics, Bucharest (Romania)]. E-mail: serbanradu@pcnet.ro; Gazdaru, D. [Bucharest Univ., Dept. of Biophysics, Physics Faculty, Bucharest (Romania); Constantinescu, B. [H. Hulubei National Inst., Dept. of Cyclotron, Bucharest (Romania)

    2004-02-01

    The effects produced by fast neutrons (0-100 Gy) on chromatin structure were analyzed by (i) [{sup 1}H]-NMR spectroscopy, (ii) time resolved spectroscopy, and (iii) fluorescence resonance energy transfer (FRET). Two types of chromatin were tested: (i) a chromatin from a normal tissue (liver of Wistar rats) and (ii) a chromatin from a tumoral tissue (Guerin limphotrope epithelioma, a rat solid tumor). The fast-neutron action on chromatin determines greater values of the [{sup 1}H]-NMR transverse relaxation time, indicating a more injured structure. Time-resolved fluorescence measurements show that the relative contribution of the excited state lifetime of bound ethidium bromide to chromatin DNA diminishes with increasing irradiation doses. This reflects the damage that occurs in DNA structure: production of single- and double-strand breaks due to sugar and base modifications. By the FRET method, the distance between dansyl chloride and acridine orange coupled at chromatin was determined. This distance increases upon fast-neutron action. The radiosensitivity of the tumor tissue chromatin seems higher than that of the normal tissue chromatin, probably because of its higher (loose) euchromatin/(compact) heterochromatin ratio. As the values of the physical parameters analyzed are specific for a determined dose, the establishment of these parameters may constitute a criterion for the microdosimetry of chromatin radiolesions produced by fast neutrons. (author)

  9. Fast neutron sensitivity of dry and germinating tomato seeds

    NARCIS (Netherlands)

    Contant, R.B.

    1970-01-01

    A study was made of changes in fast neutron effectiveness during the hydration and germination of tomato seeds. The main findings and conclusions are the following,

    Section 3.6

    Samples of unirradiated seeds and their constituent parts (seedcoat+endosperm and embryo) were taken at short

  10. RBE of fast neutrons for apoptosis in mouse thymocytes

    NARCIS (Netherlands)

    Warenius, HM; Down, JD

    1995-01-01

    We compared apoptosis in mouse thymocytes following exposure to low doses of high linear energy transfer (LET), 625-MeV (p-->Be+) fast neutrons and low LET, 4-MeV photons by flow cytometric analysis of hypodiploid cells. The incidence of apoptotic cell death rose steeply at very low radiation doses

  11. System and plastic scintillator for discrimination of thermal neutron, fast neutron, and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia P.; Carman, M. Leslie; Faust, Michelle A.; Glenn, Andrew M.; Martinez, H. Paul; Pawelczak, Iwona A.; Payne, Stephen A.

    2017-05-16

    A scintillator material according to one embodiment includes a polymer matrix; a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 3 wt % or more; and at least one component in the polymer matrix, the component being selected from a group consisting of B, Li, Gd, a B-containing compound, a Li-containing compound and a Gd-containing compound, wherein the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays. A system according to one embodiment includes a scintillator material as disclosed herein and a photodetector for detecting the response of the material to fast neutron, thermal neutron and gamma ray irradiation.

  12. Fast Neutron Dosimeter for the Space Environment Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Model calculations and risk assessment estimates indicate that secondary neutrons, with energies ranging between 0.5 to >150 MeV, make a significant contribution...

  13. Influence of thermal and resonance neutron on fast neutron flux measurement by Pu-239 fission chamber

    CERN Document Server

    zeng, Lina; Song, Lingli; Zheng, Chun

    2014-01-01

    The Pu-239 fission chambers are widely used to measure fission spectrum neutron flux due to a flat response to fast neutrons. However, in the mean time the resonance and thermal neutrons can cause a significant influence on the measurement if they are moderated, which could be eliminated by using B and Cd covers. At a column enriched uranium fast neutron critical assembly, the fission reaction rates of Pu-239 are measured as 1.791*10-16,2.350*10-16 and 1.385*10-15 per second for 15mm thick B cover, 0.5mm thick Cd cover, and no cover respectively. While the fission reaction rate of Pu-239 is rapidly increased to 2.569*10-14 for a 20mm thick polythene covering fission chamber. The average Pu-239 fission cross-section of thermal and resonance neutrons is calculated to be 500b and 24.95b with the assumption of 1/v and 1/E spectra respectively, then thermal, resonance and fast neutron flux are achieved to be 2.30*106,2.24*106 and 1.04*108cm-2s-1.

  14. Experimental setup for the determination of the correction factors of the neutron doseratemeters in fast neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Iliescu, Elena; Bercea, Sorin; Dudu, Dorin; Celarel, Aurelia [National Institute of R and D for Physics and Nuclear Engineering-Horia Hulubei, Reactorului 30 St, P.O.BOX MG-6,Magurele, cod 077125 (Romania)

    2013-12-16

    The use of the U-120 Cyclotron of the IFIN-HH allowed to perform a testing bench with fast neutrons in order to determine the correction factors of the doseratemeters dedicated to neutron measurement. This paper deals with researchers performed in order to develop the irradiation facility testing the fast neutrons flux generated at the Cyclotron. This facility is presented, together with the results obtain in determining the correction factor for a doseratemeter dedicated to the neutron dose equivalent rate measurement.

  15. Tagged fast neutron beams En > 6 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Favela, F.; Huerta, A.; Santa Rita, P.; Ramos, A. T.; Lucio, O. de; Andrade, E.; Ortiz, M. E.; Araujo, V.; Chávez, E., E-mail: chavez@fisica.unam.mx [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, México D. F. 01000 México (Mexico); Acosta, L. [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, México D. F. 01000 México (Mexico); INFN-Sezione di Catania, Via Santa Sofia 64 I-95123, Catania (Italy); Murillo, G.; Policroniades, R. [Departamento de Aceleradores, Instituto Nacional de Investigaciones Nucleares, Carr. México-Toluca S/N, Ocoyoacac, Edo. Méx., 52750 (Mexico); Varela, A. [Instituto de Ciencias de la Atmósfera, UNAM (Mexico)

    2015-07-23

    Controlled flux of neutrons are produced through the {sup 14}N(d,n){sup 15}O nuclear reaction. Deuteron beams (2-4 MeV) are delivered by the CN-Van de Graaff accelerator and directed with full intensity to our Nitrogen target at SUGAR (SUpersonic GAs jet taRget). Each neutron is electronically tagged by the detection of the associated{sup 15}O. Its energy and direction are known and “beams” of fast monochromatic tagged neutrons (E{sub n}> 6 MeV) are available for basic research and applied work. MONDE is a large area (158 × 63 cm{sup 2}) plastic scintillating slab (5 cm thick), viewed by 16 PMTs from the sides. Fast neutrons (MeV) entering the detector will produce a recoiling proton that induces a light spark at the spot. Signals from the 16 detectors are processed to deduce the position of the spark. Time logic signals from both the {sup 15}O detector and MONDE are combined to deduce a time of flight (TOF) signal. Finally, the position information together with the TOF yields the full momentum vector of each detected neutron.

  16. Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

    Science.gov (United States)

    Davis, John R.; Brubaker, Erik; Vetter, Kai

    2017-06-01

    In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. The expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. Three areas analyzed in San Francisco, Downtown Oakland, and Berkeley all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.

  17. nGEM fast neutron detectors for beam diagnostics

    Science.gov (United States)

    Croci, G.; Claps, G.; Cavenago, M.; Dalla Palma, M.; Grosso, G.; Murtas, F.; Pasqualotto, R.; Perelli Cippo, E.; Pietropaolo, A.; Rebai, M.; Tardocchi, M.; Tollin, M.; Gorini, G.

    2013-08-01

    Fast neutron detectors with a sub-millimetric space resolution are required in order to qualify neutron beams in applications related to magnetically-controlled nuclear fusion plasmas and to spallation sources. A nGEM detector has been developed for the CNESM diagnostic system of the SPIDER NBI prototype for ITER and as beam monitor for fast neutrons lines at spallation sources. The nGEM is a triple GEM gaseous detector equipped with polypropylene and polyethylene layers used to convert fast neutrons into recoil protons through the elastic scattering process. This paper describes the results obtained by testing a nGEM detector at the ISIS spallation source on the VESUVIO beam line. Beam profiles (σx=14.35 mm, σy=15.75 mm), nGEM counting efficiency (around 10-4 for 3 MeV

  18. Design of a boron neutron capture enhanced fast neutron therapy assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhonglu [Georgia Inst. of Technology, Atlanta, GA (United States)

    2006-12-01

    The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator near the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm2 treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm2 collimation was 21.9% per 100-ppm 10B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about 48.5% and 27.9% of the dose rate of the standard 10x10 cm2 fast neutron treatment beam. To validate the design calculations, a simplified BNCEFNT assembly was built using four lead bricks to form a 5x5 cm2 collimator. Five 1.0-cm thick 20x20 cm2 tungsten plates were used to obtain different filter thicknesses and graphite bricks/blocks were used to form a reflector. Measurements of the dose enhancement of the simplified assembly in a water-filled head phantom were performed using a pair of tissue-equivalent ion chambers. One of the ion chambers is loaded with 1000-ppm natural boron (184-ppm 10B) to measure dose due to boron neutron capture. The

  19. Axion star collisions with neutron stars and fast radio bursts

    Science.gov (United States)

    Raby, Stuart

    2016-11-01

    Axions may make a significant contribution to the dark matter of the Universe. It has been suggested that these dark matter axions may condense into localized clumps, called "axion stars." In this paper we argue that collisions of dilute axion stars with neutron stars, of the type known as "magnetars," may be the origin of most of the observed fast radio bursts. This idea is a variation of an idea originally proposed by Iwazaki. However, instead of the surface effect of Iwazaki, we propose a perhaps stronger volume effect caused by the induced time dependent electric dipole moment of neutrons.

  20. Axion star collisions with Neutron stars and Fast Radio Bursts

    CERN Document Server

    Raby, Stuart

    2016-01-01

    Axions may make a significant contribution to the dark matter of the universe. It has been suggested that these dark matter axions may condense into localized clumps, called "axion stars." In this paper we argue that collisions of dilute axion stars with neutron stars may be the origin of most of the observed fast radio bursts. This idea is a variation of an idea originally proposed by Iwazaki. However, instead of the surface effect of Iwazaki, we propose a perhaps stronger volume effect caused by the induced time dependent electric dipole moment of neutrons.

  1. A system of materials composition and geometry arrangement for fast neutron beam thermalization: An MCNP study

    Science.gov (United States)

    Uhlář, Radim; Alexa, Petr; Pištora, Jaromír

    2013-03-01

    Compact deuterium-tritium neutron generators emit fast neutrons (14.2 MeV) that have to be thermalized for neutron activation analysis experiments. To maximize thermal neutron flux and minimize epithermal and fast neutron fluxes across the output surface of the neutron generator facility, Monte Carlo calculations (MCNP5; Los Alamos National Laboratory) for different moderator types and widths and collimator and reflector designs have been performed. A thin lead layer close to the neutron generator as neutron multiplier followed by polyethylene moderator and surrounded by a massive lead and nickel collimator and reflector was obtained as the optimum setup.

  2. Influence of Fast Neutron Irradiation on Critical Current Densities of Bi-2223/Ag Tape

    Institute of Scientific and Technical Information of China (English)

    Duan Zhenzhong

    2004-01-01

    Experimental results on the magnetic field behavior of the critical current in silver sheathed Bi-2223 tapes are presented. The experiments consist of transport and magnetic measurements in a wide temperature range and in external magnetic field up to 6 T. Significant enhancement of the intragrain critical current densities Jc are observed after irradiation with fast neutron. This is attributed to an improvement of flux pinning capability by the neutron induced defects, but the weak link structure is somewhat damaged as evidenced by the small degradation of transport critical current at low field. According to the measurement of remanent magnetic moment before and after irradiation with fast neutron, the connectivity in Bi-2223 tapes is reduced by 50% after irradiated to a fluence of 2 × 1021 m-2, which resulted in the critical currents degradated by a factor of 10%.

  3. [The combination treatment of malignant bone tumors using fast neutrons].

    Science.gov (United States)

    Chernichenko, V A; Tolstopiatov, B A; Konovalenko, V F; Monich, A Iu; Palivets, A Iu

    1990-01-01

    The study deals with results of a clinical trial evaluating treatment efficacy of a 6 MeV neutron beam produced by Y-120 cyclotron (Kiev). Procedures of preoperative radiotherapy and radical treatment are discussed. Radiotherapy was administered to 52 patients suffering chondrosarcoma (30 cases), osteogenic sarcoma (15) or chordoma (7). Combined treatment (radiation + surgery) was given to 22 patients whereas neutron beam therapy--to 30. All patients with osteogenic sarcoma received adjuvant combination chemotherapy. Three-year survival rate was compared to that observed in controls in whom combined treatment had included gamma-therapy. A significant increase in three-year survival rate was observed for osteogenic sarcoma and chordoma whereas for chondrosarcoma the improvement in survival proved insignificant. The use of fast neutrons in combined treatment of bone tumors was considered promising.

  4. Accelerated oxygen precipitation in fast neutron irradiated Czochralski silicon

    Institute of Scientific and Technical Information of China (English)

    Ma Qiao-Yun; Li Yang-Xian; Chen Gui-Feng; Yang Shuai; Liu Li-Li; Niu Ping-Juan; Chen Dong-Feng; Li Hong-Tao

    2005-01-01

    Annealing effect of the oxygen precipitation and the induced defects have been investigated on the fast neutron irradiated Czochralski silicon (CZ-Si) by infrared absorption spectrum and the optical microscopy. It is found that the fast neutron irradiation greatly accelerates the oxygen precipitation that leads to a sharp decrease of the interstitial oxygen with the annealing time. At room temperature (RT), the 1107cm-1 infrared absorption band of interstitial oxygen becomes weak and broadens to low energy side. At low temperature, the infrared absorption peaks appear at 1078cm-1, 1096cm-1, and 1182cm-1, related to different shapes of the oxygen precipitates. The bulk microdefects,including stacking faults, dislocations and dislocation loops, were observed by the optical microscopy. New or large stacking faults grow up when the silicon self-interstitial atoms are created and aggregate with oxygen precipitation.

  5. Fast Neutron Detection Using Pixelated CdZnTe Spectrometers

    Science.gov (United States)

    Streicher, Michael; Goodman, David; Zhu, Yuefeng; Brown, Steven; Kiff, Scott; He, Zhong

    2017-07-01

    Fast neutrons are an important signature of special nuclear materials (SNMs). They have a low natural background rate and readily penetrate high atomic number materials that easily shield gamma-ray signatures. Therefore, they provide a complementary signal to gamma rays for detecting shielded SNM. Scattering kinematics dictate that a large nucleus (such as Cd or Te) will recoil with small kinetic energy after an elastic collision with a fast neutron. Charge carrier recombination and quenching further reduce the recorded energy deposited. Thus, the energy threshold of CdZnTe detectors must be very low in order to sense the small signals from these recoils. In this paper, the threshold was reduced to less than 5 keVee to demonstrate that the 5.9-keV X-ray line from 55Fe could be separated from electronic noise. Elastic scattering neutron interactions were observed as small energy depositions (less than 20 keVee) using digitally sampled pulse waveforms from pixelated CdZnTe detectors. Characteristic gamma-ray lines from inelastic neutron scattering were also observed.

  6. Fast-neutron induced background in LaBr3:Ce detectors

    CERN Document Server

    Kiener, J; Deloncle, I; de Séréville, N; Laurent, P; Blondel, C; Chabot, M; Chipaux, R; Coc, A; Dubos, S; Gostojic, A; Goutev, N; Hamadache, C; Hammache, F; Horeau, B; Limousin, O; Ouichaoui, S; Prévot, G; Rodríguez-Gasén, R; Yavahchova, M S

    2015-01-01

    The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr3:Ce detector resulting from fast neutron interactions have been obtained at 4 different neutron energies. Neutron-induced gamma rays emitted by the LaBr3:Ce crystal were also measured in a nearby Ge detector at the lowest proton beam energy. In addition, we obtained data for neutron irradiation of a large-volume high-purity Ge detector and of a NE-213 liquid scintillator detector, both serving as monitor detectors in the experiment. Monte-Carlo type simulations for neutron interactions in the liquid scintillator, the Ge and LaBr3:Ce crystals have been performed and compared with measured data. Good agreement being obtained with the data, we present the resul...

  7. Neutron diffraction test on spin-dependent short range interaction

    CERN Document Server

    Voronin, V V

    2008-01-01

    In this short note we discuss the possibility to get the constraint on the parameters of short range pseudomagnetic interaction of free neutron with matter from the crystal-diffraction experiment. It is demonstrated that for range of $\\lambda<10^{-6}$m this constraint can be a few order better than in any other method.

  8. On the problem of monitoring the neutron parameters of the Fast Energy Amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Behringer, K.; Wydler, P

    1998-10-01

    The conceptual Fast Energy Amplifier, proposed by Rubbia et al. (1995), consists of a combination of a U-233/Th-232 fuelled fast-neutron subcritical facility with a proton accelerator. An intense beam of 1 GeV protons is injected into liquid lead at the core centre and drives the reactor by producing spallation neutrons. The burst of spallation neutrons produced by a single proton alters the basic neutron statistics which are well known for thermal neutrons in conventional nuclear reactors. A short assessment of standard neutron noise analysis methods is made with respect to monitoring neutron parameter data. (author) 18 refs., 14 figs., 3 tabs.

  9. Preliminary investigations of Monte Carlo Simulations of neutron energy and LET spectra for fast neutron therapy facilities

    CERN Document Server

    Kroc, T K

    2012-01-01

    No fast neutron therapy facility has been built with optimized beam quality based on a thorough understanding of the neutron spectrum and its resulting biological effectiveness. A study has been initiated to provide the information necessary for such an optimization. Monte Carlo studies will be used to simulate neutron energy spectra and LET spectra. These studies will be bench-marked with data taken at existing fast neutron therapy facilities. Results will also be compared with radiobiological studies to further support beam quality optimization. These simulations, anchored by this data, will then be used to determine what parameters might be optimized to take full advantage of the unique LET properties of fast neutron beams. This paper will present preliminary work in generating energy and LET spectra for the Fermilab fast neutron therapy facility.

  10. Fast neutron dosimetry. Progress report, July 1, 1979-June 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Attix, F.H.

    1980-01-01

    Progress is reported in: the development and testing of new gas mixtures more suitable for fast neutron dosimetry using the common A150-type Tissue-equivalent plastic ion chambers; comparison of photon doses determined with a graphite-walled proportional counter and with paired dosimeters irradiated by 14.8-MeV neutrons; a detector for the direct measurement of LET distributions from irradiation with fast neutrons; LET distributions from fast neutron irradiation of TE-plastic and graphite measured in a cylindrically symmetric geometry; progress in development of a tandem fast neutron and /sup 60/Co gamma ray source irradiation facility; an approach to the correlation of cellular response with lineal energy; calculated and measured HTO atmospheric dispersion rates within meters of a release site; application of cavity theory to fast neutrons; and fast neutron dosimetry by thermally stimulated currents in Al/sub 2/O/sub 3/. (GHT)

  11. Fast-Neutron Survey With Compact Plastic Scintillation Detectors.

    Science.gov (United States)

    Preston, Rhys M; Tickner, James R

    2017-07-01

    With the rise of the Silicon Photomultiplier (SiPM), it is now practical to build compact scintillation detectors well suited to portable use. A prototype survey meter for fast-neutrons and gamma-rays, based around an EJ-299-34 plastic scintillator with SiPM readout, has been developed and tested. A custom digital pulse processor was used to perform pulse shape discrimination on-the-fly. Ambient dose equivalent H*(10) was calculated by means of two energy-dependent 'G-functions'. The sensitivity was calculated to be between 0.10 and 0.22 cps/(µSv/hr) for fast-neutrons with energies above 2.5 MeV. The prototype was used to survey various laboratory radiation fields, with the readings compared with commercial survey meters. The high sensitivity and lightweight nature of this detector makes it promising for rapid survey of the mixed neutron/gamma-ray fields encountered in industry and homeland security. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Optimization of CR-39 for fast neutron dosimetry applications

    CERN Document Server

    Vilela, E; Giacomelli, G; Giorgini, M; Morelli, B; Patrizii, L; Serra, P; Togo, V

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: sup 2 sup 4 sup 1 Am-Be, sup 2 sup 5 sup 2 Cf and sup 2 sup 3 sup 8 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose.

  13. A feasibility study using radiochromic films for fast neutron 2D passive dosimetry

    Science.gov (United States)

    Brady, Samuel L.; Gunasingha, Rathnayaka; Yoshizumi, Terry T.; Howell, Calvin R.; Crowell, Alexander S.; Fallin, Brent; Tonchev, Anton P.; Dewhirst, Mark W.

    2010-09-01

    The objective of this paper is threefold: (1) to establish sensitivity of XRQA and EBT radiochromic films to fast neutron exposure; (2) to develop a film response to radiation dose calibration curve and (3) to investigate a two-dimensional (2D) film dosimetry technique for use in establishing an experimental setup for a radiobiological irradiation of mice and to assess the dose to the mice in this setup. The films were exposed to a 10 MeV neutron beam via the 2H(d,n)3He reaction. The XRQA film response was a factor of 1.39 greater than EBT film response to the 10 MeV neutron beam when exposed to a neutron dose of 165 cGy. A film response-to-soft tissue dose calibration function was established over a range of 0-10 Gy and had a goodness of fit of 0.9926 with the calibration data. The 2D film dosimetry technique estimated the neutron dose to the mice by measuring the dose using a mouse phantom and by placing a piece of film on the exterior of the experimental mouse setup. The film results were benchmarked using Monte Carlo and aluminum (Al) foil activation measurements. The radiochromic film, Monte Carlo and Al foil dose measurements were strongly correlated, and the film within the mouse phantom agreed to better than 7% of the externally mounted films. These results demonstrated the potential application of radiochromic films for passive 2D neutron dosimetry.

  14. Feasibility of the Utilization of BNCT in the Fast Neutron Therapy Beam at Fermilab

    Science.gov (United States)

    Langen, Katja; Lennox, Arlene J.; Kroc, Thomas K.; DeLuca, Jr., Paul M.

    2000-06-01

    The Neutron Therapy Facility at Fermilab has treated cancer patients since 1976. Since then more than 2,300 patients have been treated and a wealth of clinical information accumulated. The therapeutic neutron beam at Fermilab is produced by bombarding a beryllium target with 66 MeV protons. The resulting continuous neutron spectrum ranges from thermal to 66 MeV in neutron energy. It is clear that this spectrum is not well suited for the treatment of tumors with boron neutron capture therapy (BNCT) only However, since this spectrum contains thermal and epithermal components the authors are investigating whether BNCT can be used in this beam to boost the tumor dose. There are clinical scenarios in which a selective tumor dose boost of 10 - 15% could be clinically significant. For these cases the principal treatment would still be fast neutron therapy but a tumor boost could be used either to deliver a higher dose to the tumor tissue or to reduce the dose to the normal healthy tissue while maintaining the absorbed dose level in the tumor tissue.

  15. A novel detector assembly for detecting thermal neutrons, fast neutrons and gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Cester, D., E-mail: davide.cester@gmail.com [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); Lunardon, M.; Moretto, S. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Nebbia, G. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Pino, F. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); Sajo-Bohus, L. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); Laboratorio de Fisica Nuclear, Universidad Simon Bolivar, Apartado 89000, 1080 A Caracas (Venezuela, Bolivarian Republic of); Stevanato, L.; Bonesso, I.; Turato, F. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy)

    2016-09-11

    A new composite detector has been developed by combining two different commercial scintillators. The device has the capability to detect gamma rays as well as thermal and fast neutrons; the signal discrimination between the three types is performed on-line by means of waveform digitizers and PSD algorithms. This work describes the assembled detector and its discrimination performance to be employed in the applied field.

  16. Relative biological effectiveness and tolerance dose of fission neutrons in canine skin for a potential combination of neutron capture therapy and fast-neutron therapy.

    Science.gov (United States)

    Kadosawa, Tsuyoshi; Ohashi, Fumihito; Nishimura, Ryohei; Sasaki, Nobuo; Saito, Isao; Wakabayashi, Hiroaki; Takeuchi, Akira

    2003-10-01

    To investigate the potential efficacy of fission neutrons from a fast-neutron reactor for the treatment of radioresistant tumors, the relative biological effectiveness (RBE) and tolerance dose of fission neutrons in canine skin were determined. The forelimbs of 34 healthy mongrel dogs received a single dose of fission neutrons (5.6, 6.8, 8.2, 9.6 or 11 Gy) or 137Cs gamma rays (10, 15, 20, 25 or 30 Gy). Based on observations of radiodermatitis for each radiation, the single-fraction RBE of fission neutrons in the sixth month was calculated as approximately 3. The tolerance doses of fission neutrons and gamma rays, defined as the highest doses giving no moist desquamation on the irradiated skin in the recovery phase, were estimated as 7.6 Gy and 20 Gy, respectively. The tolerance dose of 7.6 Gy of fission neutrons included 5.0 Gy of fast neutrons possessing high anti-tumor effects and 1.4 x 10(12) n/cm2 of thermal neutrons, which could be applicable to neutron capture therapy (NCT). The combination of fast-neutron therapy and NCT using a fast-neutron reactor might be useful for the treatment of radioresistant tumors.

  17. Fast Envelope Correlation for Passive Ranging

    Science.gov (United States)

    1991-09-01

    Ref. l:p. 27]. Range (meters; / 𔃺 Transmittng Radar Sen or I Sensor 2 Range turete,,; (focal point 1) (focal point 2) Hyperbola for t d I ms. d td ...Scaling noise is zero because it is not performed during pass five. Substituting Equation 81 into 82 NA2(5) = 25N2 + (25 + 24)S2o, + 7o0 (83) Pass 6 The

  18. Radiolysis of Boric Acid Solutions under Mixed Thermal and Fast Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Im, Heejung; Choi, Ke Chon; Yeon, Jeiwon; Song, Kyuseok; Jung Hoansung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The thermal neutron irradiation of water samples containing neutron absorbers has not been published except for a paper reporting the experimental data obtained at high temperatures. However, irradiation or simulations of water and voluminous liquid samples with fast neutrons and gamma rays are frequently discussed in several published papers. Several water samples containing {sup 10}B-enriched boric acid, and natural and {sup 10}B-enriched mixed boric acids in the range of 0 to 2000 μg/mL for the function of {sup 10}B concentration, were irradiated to study the radiolysis of the cooling water containing boric acid. The concentration of natural boron in the primary coolant of pressurized water reactors (PWRs) is known to start at 1500 μg/mL, and boric acid is used for the purpose of nuclear reaction control.

  19. Neutron diffraction analysis of Cr-Ni-Mo-Ti austenitic steel after cold plastic deformation and fast neutrons irradiation

    Science.gov (United States)

    Voronin, V. I.; Valiev, E. Z.; Berger, I. F.; Goschitskii, B. N.; Proskurnina, N. V.; Sagaradze, V. V.; Kataeva, N. F.

    2015-04-01

    A quantitative assessment is presented of the dislocation density and relative fractions of edge and screw dislocations in reactor-steel samples 16Cr-15Ni-3Mo-1Ti subjected to preliminary cold deformation by rolling and subsequent fast neutron irradiation using neutron diffraction analysis. The Williamson-Hall modified method was used for calculations. It is shown that the fast neutron irradiation leads to a decrease in the density of dislocations that appeared after samples deformation. The applicability of neutron diffraction analysis to the examination of dislocation structure of deformed and irradiated materials is shown.

  20. Microstructural evolution in fast-neutron-irradiated austenitic stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Stoller, R.E.

    1987-12-01

    The present work has focused on the specific problem of fast-neutron-induced radiation damage to austenitic stainless steels. These steels are used as structural materials in current fast fission reactors and are proposed for use in future fusion reactors. Two primary components of the radiation damage are atomic displacements (in units of displacements per atom, or dpa) and the generation of helium by nuclear transmutation reactions. The radiation environment can be characterized by the ratio of helium to displacement production, the so-called He/dpa ratio. Radiation damage is evidenced microscopically by a complex microstructural evolution and macroscopically by density changes and altered mechanical properties. The purpose of this work was to provide additional understanding about mechanisms that determine microstructural evolution in current fast reactor environments and to identify the sensitivity of this evolution to changes in the He/dpa ratio. This latter sensitivity is of interest because the He/dpa ratio in a fusion reactor first wall will be about 30 times that in fast reactor fuel cladding. The approach followed in the present work was to use a combination of theoretical and experimental analysis. The experimental component of the work primarily involved the examination by transmission electron microscopy of specimens of a model austenitic alloy that had been irradiated in the Oak Ridge Research Reactor. A major aspect of the theoretical work was the development of a comprehensive model of microstructural evolution. This included explicit models for the evolution of the major extended defects observed in neutron irradiated steels: cavities, Frank faulted loops and the dislocation network. 340 refs., 95 figs., 18 tabs.

  1. Some Applications of Fast Neutron Activation Analysis of Oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Owrang, Farshid

    2003-07-01

    In this thesis we focus on applications of neutron activation of oxygen for several purposes: A) measuring the water level in a laboratory tank, B) measuring the water flow in a pipe system set-up, C) analysing the oxygen in combustion products formed in a modern gasoline SI engine, and D) measuring on-line the amount of oxygen in bulk liquids. A) Water level measurements. The purpose of this work was to perform radiation based water level measurements, aimed at nuclear reactor vessels, on a laboratory scale. A laboratory water tank was irradiated by fast neutrons from a neutron generator. The water was activated at different water levels and the water level was decreased. The produced gamma radiation was measured using two detectors at different heights. The results showed that the method is suitable for measurement of water level and that a relatively small experimental set-up can be used for developing methods for water level measurements in real boiling water reactors based on activated oxygen in the water. B) Water flows in pipe. The goal in this work was to investigate the asymmetric distribution of activity in flow measurements with pulsed neutron activation (PNA) in a laboratory piping system. Earlier investigations had shown a discrepancy between the measured velocity of the activated water by PNA and the true mean velocity in the pipe. This discrepancy decreased with larger distances from the activation point. It was speculated that the induced activity in the pipe did not distribute homogeneously. With inhomogeneous radial distribution of activity in combination with a velocity profile in the pipe, the activated water may not have the same velocity as the mean velocity of water in the pipe. To study this phenomenon, a water-soluble colour was injected into a transparent pipe for simulation of the transport of the activated water. The radial concentration of the colour, at different distances from the activation point, was determined. The result

  2. Bubble masks for time-encoded imaging of fast neutrons.

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, Erik; Brennan, James S.; Marleau, Peter; Nowack, Aaron B.; Steele, John T.; Sweany, Melinda; Throckmorton, Daniel J.

    2013-09-01

    Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is inducedtypically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gapsbubblespropagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.

  3. The pilot experimental study of 14 MeV fast neutron digital radiography

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    14 MeV Fast neutrons has good penetrability and the 14 MeV fast neutron radiography can meet the need of Non-Destructive Test of the structure and lacuna of heavy-massive sample, whose shell is made of heavy metal and in which there are some hydrogen materials, and the study of fast neutron digital radiography just begins in China. By the use of a D-T accelerator, a digital imaging system made up of a fast neutron scintillation screen made of ZnS(Ag) and polypropylene, lens and a scientific grade CCD, the experimental study of fast neutron radiography has been done between 4.3×1010-6.8×1010 n/s of neutron yield. Some 14 MeV fast neutron digital radiographs have been gotten. According to experimental radiographs and their data, the performance of the fast neutron scintillation screen and the basic characters of 14 MeV fast neutron radiography are analyzed, and it is helpful for the further research.

  4. The pilot experimental study of 14 MeV fast neutron digital radiography

    Institute of Scientific and Technical Information of China (English)

    TANG Bin; ZHOU ChangGen; HUO HeYong; WU Yang; LIU Bin; LOU BenChao; SUN Yong

    2009-01-01

    14 MeV Fast neutrons has good penetrability and the 14 MeV fast neutron radiography can meet the need of Non-Destructive Test of the structure and lacuna of heavy-massive sample,whose shell is made of heavy metal and in which there are some hydrogen materials,and the study of fast neutron digital radiography just begins in China.By the use of a D-T accelerator,a digital imaging system made up of a fast neutron scintillation screen made of ZnS(Ag) and polypropylene,lens and a scientific grade CCD,the experimental study of fast neutron radiography has been done between 4.3×1010-6.8×1010 n/s of neutron yield.Some 14 MeV fast neutron digital radiographs have been gotten.According to ex-perimental radiographs and their data,the performance of the fast neutron scintillation screen and the basic characters of 14 MeV fast neutron radiography are analyzed,and it is helpful for the further re-search.

  5. Final report on graphite irradiation test OG-3. [Fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Price, R.J.; Beavan, L.A.

    1977-01-01

    The results of dimensional, thermal expansivity, thermal conductivity, Young's modulus, and tensile strength measurements on graphite specimens irradiated in capsule OG-3 are presented. The graphite grades investigated included near-isotropic H-451 (three different preproduction lots), TS-1240, and SO818; needle coke H-327; and European coal tar pitch coke grades P/sub 3/JHA/sub 2/N, P/sub 3/JHAN, and ASI2-500. Data were obtained in the temperature range 823/sup 0/K to 1673/sup 0/K. The peak fast neutron fluence in the experiment was 3 x 10/sup 25/ n/m/sup 3/ (E greater than 29 fJ)/sub HTGR/; the total accumulated fluence exceeded 9 x 10/sup 25/ n/m/sup 2/ on some H-451 specimens and 6 x 10/sup 25/ n/m/sup 2/ on some TS-1240 specimens. Irradiation-induced dimensional changes on H-451 graphite differed slightly from earlier predictions. For an irradiation temperature of about 1225/sup 0/K, axial shrinkage rates at high fluences were somewhat higher than predicted, and the fluence at which radial expansion started (about 9 x 10/sup 25/ n/m/sup 2/ at 1275/sup 0/K) was lower. TS-1240 graphite underwent smaller dimensional changes than H-451 graphite, while limited data on SO818 and ASI2-500 graphites showed similar behavior to H-451. P/sub 3/JHAN and P/sub 3/JHA/sub 2/N graphites displayed anisotropic behavior with rapid axial shrinkage. Comparison of dimensional changes between specimens from three logs of H-451 and of TS-1240 graphites showed no significant log-to-log variations for H-451, and small but significant log-to-log variations for TS-1240. The thermal expansivity of the near-isotropic graphites irradiated at 865-1045/sup 0/K first increased by 5 percent to 10 percent and then decreased. At higher irradiation temperatures the thermal expansivity decreased by up to 50 percent. Changes in thermal conductivity were consistent with previously established curves. Specimens which were successively irradiated at two different temperatures took on the

  6. Absolute Calibration of Proportional Counter Based Fast Pulsed Neutron Detectors with Resolution Below 105 neutron/pulse

    Science.gov (United States)

    Tarifeño-Saldivia, A.; Mayer, R. E.; Pavez, C.; Soto, L.

    2014-05-01

    A method for absolute calibration of proportional counters for pulsed fast neutrons is presented. The method is based on the use of an isotopic standard source and development of a model for counting detected events from area of a signal compounded by single piled up neutron pulses. Effects of detection counting statistics and electrical background noise are also considered. The method is applied in detectors used for D-D neutron yield measurements in low emission plasma focus devices.

  7. Fast neutron measurements with 7Li and 6Li enriched CLYC scintillators

    Science.gov (United States)

    Giaz, A.; Blasi, N.; Boiano, C.; Brambilla, S.; Camera, F.; Cattadori, C.; Ceruti, S.; Gramegna, F.; Marchi, T.; Mattei, I.; Mentana, A.; Million, B.; Pellegri, L.; Rebai, M.; Riboldi, S.; Salamida, F.; Tardocchi, M.

    2016-07-01

    The recently developed Cs2LiYCl6:Ce (CLYC) crystals are interesting scintillation detectors not only for their gamma energy resolution (<5% at 662 keV) but also for their capability to identify and measure the energy of both gamma rays and fast/thermal neutrons. The thermal neutrons were detected by the 6Li(n,α)t reaction while for the fast neutrons the 35Cl(n,p)35S and 35Cl(n,α)32P neutron-capture reactions were exploited. The energy of the outgoing proton or α particle scales linearly with the incident neutron energy. The kinetic energy of the fast neutrons can be measured using both the Time Of Flight (TOF) technique and using the CLYC energy signal. In this work, the response to monochromatic fast neutrons (1.9-3.8 MeV) of two CLYC 1″×1″ crystals was measured using both the TOF and the energy signal. The observables were combined to identify fast neutrons, to subtract the thermal neutron background and to identify different fast neutron-capture reactions on 35Cl, in other words to understand if the detected particle is an α or a proton. We performed a dedicated measurement at the CN accelerator facility of the INFN Legnaro National Laboratories (Italy), where the fast neutrons were produced by impinging a proton beam (4.5, 5.0 and 5.5 MeV) on a 7LiF target. We tested a CLYC detector 6Li-enriched at about 95%, which is ideal for thermal neutron measurements, in parallel with another CLYC detector 7Li-enriched at more than 99%, which is suitable for fast neutron measurements.

  8. Fast neutron measurements with {sup 7}Li and {sup 6}Li enriched CLYC scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Giaz, A., E-mail: agnese.giaz@mi.infn.it [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Blasi, N.; Boiano, C.; Brambilla, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Camera, F. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Cattadori, C. [INFN sezione di Milano Bicocca, Piazza della Scienza 3, 20125 Milano (Italy); Ceruti, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Gramegna, F.; Marchi, T. [INFN Laboratori Nazionali di Legnaro, Viale dell’Università, 2, 35020 Legnaro, PD (Italy); Mattei, I. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Mentana, A. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Million, B.; Pellegri, L. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Rebai, M. [Università degli Studi di Milano Bicocca, Physics Department, Piazza della Scienza 3, 20126 Milano (Italy); Riboldi, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Salamida, F. [INFN sezione di Milano Bicocca, Piazza della Scienza 3, 20125 Milano (Italy); Tardocchi, M. [Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, Via R. Cozzi 53, 2015 Milano (Italy)

    2016-07-21

    The recently developed Cs{sub 2}LiYCl{sub 6}:Ce (CLYC) crystals are interesting scintillation detectors not only for their gamma energy resolution (<5% at 662 keV) but also for their capability to identify and measure the energy of both gamma rays and fast/thermal neutrons. The thermal neutrons were detected by the {sup 6}Li(n,α)t reaction while for the fast neutrons the {sup 35}Cl(n,p){sup 35}S and {sup 35}Cl(n,α){sup 32}P neutron-capture reactions were exploited. The energy of the outgoing proton or α particle scales linearly with the incident neutron energy. The kinetic energy of the fast neutrons can be measured using both the Time Of Flight (TOF) technique and using the CLYC energy signal. In this work, the response to monochromatic fast neutrons (1.9–3.8 MeV) of two CLYC 1″×1″ crystals was measured using both the TOF and the energy signal. The observables were combined to identify fast neutrons, to subtract the thermal neutron background and to identify different fast neutron-capture reactions on {sup 35}Cl, in other words to understand if the detected particle is an α or a proton. We performed a dedicated measurement at the CN accelerator facility of the INFN Legnaro National Laboratories (Italy), where the fast neutrons were produced by impinging a proton beam (4.5, 5.0 and 5.5 MeV) on a {sup 7}LiF target. We tested a CLYC detector {sup 6}Li-enriched at about 95%, which is ideal for thermal neutron measurements, in parallel with another CLYC detector {sup 7}Li-enriched at more than 99%, which is suitable for fast neutron measurements.

  9. Monte Carlo simulation of the response to fast neutrons of a multi-gap RPC (MRPC) by using the GEANT4 code

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, J. T.; Jo, H. Y.; Jamil, M.; Jeon, Y. J. [Konkuk University, Seoul (Korea, Republic of)

    2012-04-15

    This article reports the simulated response to fast neutrons of a multi-gap resistive plate chamber (MRPC) by using the GEANT4 MC code. In this study, a thin polyethylene layer, which acted as the converter material for the detection of fast neutrons, was coated on the surface of the MRPC, which acts as the converter material for the detection of fast neutrons. The converter based on the polyethylene material improved the chamber's ability to detect fast neutrons. By employing the GEANT4 MC code, fast neutrons were inserted into the converter-based MRPC chamber in the energy range of 1.0 - 20.0 MeV. The response of the polyethylene-coated MRPC were evaluated as a function of the neutron energy by using the QGSP{sub B}ERT{sub H}P and the QGSP{sub B}IC{sub H}P physics list with the GEANT4 code. For a 0.13-mm converter thickness, a detection efficiency of 6.4x10{sup -3} were found for fast neutrons with an energy of E{sub n} = 6.0 by the QGSP{sub B}ERT{sub H}P physics list. The simulation test further confirmed that a higher response of the fast neutrons could be achieved if the converter thickness were to be increased. A detailed outline of the simulation test and the obtained results are presented.

  10. A re-sequencing based assessment of genomic heterogeneity and fast neutron-induced deletions in a common bean cultivar

    Directory of Open Access Journals (Sweden)

    Jamie A. O'Rourke

    2013-06-01

    Full Text Available A small fast neutron mutant population has been established from Phaseolus vulgaris cv. Red Hawk. We leveraged the available P. vulgaris genome sequence and high throughput next generation DNA sequencing to examine the genomic structure of five Phaseolus vulgaris cv. Red Hawk fast neutron mutants with striking visual phenotypes. Analysis of these genomes identified three classes of structural variation; between cultivar variation, natural variation within the fast neutron mutant population, and fast neutron induced mutagenesis. Our analyses focused on the latter two classes. We identified 23 large deletions (>40 bp common to multiple individuals, illustrating residual heterogeneity and regions of structural variation within the common bean cv. Red Hawk. An additional 18 large deletions were identified in individual mutant plants. These deletions, ranging in size from 40 bp to 43,000 bp, are potentially the result of fast neutron mutagenesis. Six of the 18 deletions lie near or within gene coding regions, identifying potential candidate genes causing the mutant phenotype.

  11. Neutron Age Determination in Fast Reactor Materials using the Group Method

    Directory of Open Access Journals (Sweden)

    Kabanova Marina F.

    2016-01-01

    Full Text Available The article deals with the methods of identifying fast neutron age in sodium (Na and uranium-238 (238U; describes the model of advanced and effective fast neutron nuclear reactors (FN, where Na is a coolant while 238U is involved in the fuel cycle in large quantities; justifies the choice of the group method for calculating the neutron age value in the substances mentioned above that can show the accuracy of the used constants for Na and estimate various versions of multilevel description of neutron moderation in 238U – the most powerful resonance absorber of the neutron reactor active zone.

  12. Measurement of Insulation Compaction in the Cryogenic Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

    Science.gov (United States)

    Livingston, R. A.; Schweitzer, J. S.; Parsons, Ann M.; Arens, Ellen E.

    2010-01-01

    The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.

  13. Genome resilience and prevalence of segmental duplications following fast neutron irradiation of soybean

    Science.gov (United States)

    Fast neutron radiation has been used as a mutagen to develop extensive mutant collections. However, the genome-wide structural consequences of fast neutron radiation are not well understood. Here, we examine the genome-wide structural variants observed among 264 soybean (Glycine max (L.) Merrill) pl...

  14. Improvements in fast-neutron spectroscopy methods (1961); Amelioration des methodes de spectrometrie des neutrons rapides (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Cambou, F. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    This research aimed at improving fast-neutron electronic detectors based on n-p elastic scattering. The first part concerns proportional counters; careful constructional methods have made it possible to plot mono-energetic neutron spectra in the range 700 keV - 3 MeV with a resolution of 7 per cent. The second part concerns scintillation counters: an organic scintillator and an inorganic scintillator covered with a thin layer of a scattering agent. An exact study of the types of scintillation has made it possible to develop efficient discriminator circuits. Different neutron spectra plotted in the presence of a strong gamma background are presented. The last part deals with the development of form discrimination methods for the study, in the actual beam, of the elastic scattering of 14.58 MeV electrons. With hydrogen, the distribution f ({phi}) of the recoil protons is f({phi}) = 1 + 0.034 cos {phi} + 0.042 cos{sup 2} {phi}. With tritium the scattering is strongly anisotropic; the curve representing the variation of the differential cross-section for the elastic scattering in the centre of mass system is obtained with a target containing 1 cm{sup 3} of tritium. (author) [French] Le travail a porte sur l'amelioration des detecteurs electroniques de neutrons rapides bases sur la diffusion elastique n-p. La premiere partie est relative aux compteurs proportionnels; des methodes soignees de fabrication ont permis des traces de spectres de neutrons monoenergetiques dans le domaine 700 keV - 3 MeV avec une resolution de 7 pour cent. La deuxieme partie est relative au compteur a scintillations; scintillateur organique et scintillateur mineral recouvert d'un diffuseur mince. Une etude precise des formes de scintillations a permis la mise au point de circuits discriminateurs efficaces. Differents spectres de neutrons traces en presence d'un fond gamma intense sont presentes. La derniere partie est relative a la mise en oeuvre des methodes de discrimination de

  15. The preliminary results of fast neutron flux measurements in the DULB laboratory at Baksan

    OpenAIRE

    2000-01-01

    One of the main sources of a background in underground physics experiments (such as the investigation of solar neutrino flux, neutrino oscillations, neutrinoless double beta decay, and the search for annual and daily Cold Dark Matter particle flux modulation) are fast neutrons originating from the surrounding rocks. The measurements of fast neutron flux in the new DULB Laboratory situated at a depth of 4900 m w.e. in the Baksan Neutrino Observatory have been performed. The relative neutron sh...

  16. Fast neutron leakage in 18 MeV medical electron accelerator

    CERN Document Server

    Paredes, L; Balcazar, M; Tavera, L; Camacho, E

    1999-01-01

    In this work the neutron fluence of the Varian Clinac 2100C Medical Accelerator has been evaluated using CR39 track dosimeter. The assessment of fast neutron dose to a patient for typical treatment of 200 cGy with an 18 MV photons beam is performed at surface-source distance of 100 cm with a field size of 20x20 cm sup 2. Fast neutron leakage around of the accelerator head is evaluated.

  17. Fast Neutron Damage Studies on NdFeB Materials

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.; Spencer, J.; Wolf, Z.; /SLAC; Baldwin, A.; Pellett, D.; Boussoufi, M.; /UC, Davis

    2005-05-17

    Many materials and electronics need to be tested for the radiation environment expected at linear colliders (LC) since both accelerator and detectors will be subjected to large fluences of hadrons, leptons and {gamma}'s over the life of the facility [1]. While the linacs will be superconducting, there are still many uses for NdFeB in the damping rings, injection and extraction lines and final focus. Our understanding of the situation for rare earth, permanent magnet materials was presented at PAC03 [2]. Our first measurements of fast neutron, stepped doses at the UC Davis McClellan Nuclear Reactor Center (UCD MNRC) were presented at EPAC04 [3]. We have extended the doses, included other manufacturer's samples, and measured induced radioactivities which are discussed in detail.

  18. Fast Neutron Damage Studies on NdFeB Materials

    CERN Document Server

    Spencer, James; Baldwin, A; Boussoufi, Moe; Pellet, David; Volk, James T; Wolf, Zachary

    2005-01-01

    Many materials and electronics need to be tested for the radiation environment expected at linear colliders (LC) where the accelerator and detectors will be subjected to large fluences of hadrons, leptons and gammas over the life of the facility. Although the linacs will be superconducting, there are still many potential uses for NdFeB in the damping rings, injection and extraction lines and final focus. Our understanding of the radiation damage situation for rare earth permanent magnet materials was presented at PAC2003 and our first measurements of fast neutron, stepped doses at the UC Davis McClellan Nuclear Reactor Center (UCD MNRC) were presented at EPAC2004 where the damage appeared proportional to the distances between the effective operating points and Hc. Here we have extended those doses and included more commercial samples together with the induced radioactivities associated with their respective dopants. Hall probe data for the external induction distributions are compared with vector magnetizatio...

  19. Mechanisms of fast neutron penetration in thick layers of sodium

    Energy Technology Data Exchange (ETDEWEB)

    Huang, L.Y.

    1975-01-01

    A series of computer experiments was carried out to elucidate the penetration mechanisms of fast neutrons through thick layers of sodium such as occur in LMFBR designs. As a one-dimensional approximation of the actual situation, the calculations concentrated mainly on the flux 5 meters from a plane isotropic fission source in an infinite sodium medium. Most of the transport calculations were made with the moments-method code BMT with a 496-energy point grid. Previously developed methods for reconstructing the flux from the spatial moments were used, except that a set of biorthogonal polynomials was constructed suitable for expansion of the flux in terms of a Gaussian weight function. The moments-method technique lends itself to easy and economical changes of the input cross section data. A large number of such modified cross section sets, built around the ENDF/B-III set, were used in separate calculations designed variously to emphasize or eliminate one or more particular transport processes. It was shown that, as the energy decreases below 190 keV, the flux spectrum at 5 m is increasingly dominated by an age-diffusion process that is quantitatively close to conventional age theory if the age is suitably chosen. Conclusions from this picture of neutron penetration in sodium are made as to the types of transport calculations that can be successfully made in shield design, and the accuracies needed in future cross section measurements. 37 figures, 30 tables.

  20. Computational Neutronics Methods and Transmutation Performance Analyses for Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    R. Ferrer; M. Asgari; S. Bays; B. Forget

    2007-03-01

    The once-through fuel cycle strategy in the United States for the past six decades has resulted in an accumulation of Light Water Reactor (LWR) Spent Nuclear Fuel (SNF). This SNF contains considerable amounts of transuranic (TRU) elements that limit the volumetric capacity of the current planned repository strategy. A possible way of maximizing the volumetric utilization of the repository is to separate the TRU from the LWR SNF through a process such as UREX+1a, and convert it into fuel for a fast-spectrum Advanced Burner Reactor (ABR). The key advantage in this scenario is the assumption that recycling of TRU in the ABR (through pyroprocessing or some other approach), along with a low capture-to-fission probability in the fast reactor’s high-energy neutron spectrum, can effectively decrease the decay heat and toxicity of the waste being sent to the repository. The decay heat and toxicity reduction can thus minimize the need for multiple repositories. This report summarizes the work performed by the fuel cycle analysis group at the Idaho National Laboratory (INL) to establish the specific technical capability for performing fast reactor fuel cycle analysis and its application to a high-priority ABR concept. The high-priority ABR conceptual design selected is a metallic-fueled, 1000 MWth SuperPRISM (S-PRISM)-based ABR with a conversion ratio of 0.5. Results from the analysis showed excellent agreement with reference values. The independent model was subsequently used to study the effects of excluding curium from the transuranic (TRU) external feed coming from the LWR SNF and recycling the curium produced by the fast reactor itself through pyroprocessing. Current studies to be published this year focus on analyzing the effects of different separation strategies as well as heterogeneous TRU target systems.

  1. A high resolution, low background fast neutron spectrometer

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S; Adams, J M; Nico, J S; Thompson, A K

    2002-01-01

    We discuss the possibility to create a spectrometer of full absorption based on liquid scintillator doped with enriched sup 6 Li. Of specific interest, the spectrometer will have energy resolution estimated to lie in the range 5-10% for 14 MeV neutrons. It will be sensitive to fluxes from 10 sup - sup 4 to 10 sup 6 cm sup - sup 2 s sup - sup 1 above a threshold of 1 MeV in a gamma-background of up to 10 sup 4 s sup - sup 1. The detector's efficiency will be determined by the volume of the scintillator only (approx 3 l) and is estimated to be 0.2-10%. The main reason for the poor resolution of an organic scintillator based spectrometer of full absorption is a non-linear light-yield of the scintillator for recoil protons. The neutron energy is occasionally distributed among recoil protons, and due to non-linear light-yield the total amount of light from all recoil protons ambiguously determines the initial neutron energy. The high-energy resolution will be achieved by compensation of the non-linear light-yield ...

  2. The Effect of Combining Fast Neutron and Photon Irradiation on the Human Osteosarcoma OS-732 Cell Line

    Institute of Scientific and Technical Information of China (English)

    Linchun Feng; Lin Ma; Jingxiang Huang; Dong Yang; Yingxuan Wang; Mingxue Sun; Jinhua Tang; Weike Chang; Chengxiang Liu

    2005-01-01

    OBJECTIVE To determine the lethal effect of combining fast neutron with photon radiation on the OS-732 cell line.METHODS We examined the effect of irradiation by fast neutrons, photons and a mixed beam (fast neutrons plus photons) on the lethality and colony forming ability of the OS-732 cell line at different times.RESULTS Following a single irradiation close, the lethality was markedly strong at 24, 48 and 72 h in the group treated with fast neutrons alone and in the mixed beam group in which there was a high proportion of fast neutrons.CONCLUSION The lethal effect of a fast neutron and mixed beam with a high proportion of fast neutrons on the OS-732 cell line is highly significant. These studies provide guidance for the clinical application of fast neutrons for osteosarcoma treatment.

  3. The CLYC-6 and CLYC-7 response to γ-rays, fast and thermal neutrons

    Science.gov (United States)

    Giaz, A.; Pellegri, L.; Camera, F.; Blasi, N.; Brambilla, S.; Ceruti, S.; Million, B.; Riboldi, S.; Cazzaniga, C.; Gorini, G.; Nocente, M.; Pietropaolo, A.; Pillon, M.; Rebai, M.; Tardocchi, M.

    2016-02-01

    The crystal Cs2LiYCl6:Ce (CLYC) is a very interesting scintillator material because of its good energy resolution and its capability to identify γ-rays and fast/thermal neutrons. The crystal Cs2LiYCl6:Ce contains 6Li and 35Cl isotopes, therefore, it is possible to detect thermal neutrons through the reaction 6Li(n, α)t while 35Cl ions allow to measure fast neutrons through the reactions 35Cl(n, p)35S and 35Cl(n, α)32P. In this work two CLYC 1″×1″ crystals were used: the first crystal, enriched with 6Li at 95% (CLYC-6) is ideal for thermal neutron measurements while the second one, enriched with 7Li at >99% (CLYC-7) is suitable for fast neutron measurements. The response of CLYC scintillators was measured with different PMT models: timing or spectroscopic, with borosilicate glass or quartz window. The energy resolution, the neutron-γ discrimination and the internal activity are discussed. The capability of CLYC scintillators to discriminate γ rays from neutrons was tested with both thermal and fast neutrons. The thermal neutrons were measured with both detectors, using an AmBe source. The measurements of fast neutrons were performed at the Frascati Neutron Generator facility (Italy) where a deuterium beam was accelerated on a deuterium or on a tritium target, providing neutrons of 2.5 MeV or 14.1 MeV, respectively. The different sensitivity to thermal and fast neutrons of a CLYC-6 and of a CLYC-7 was additionally studied.

  4. The CLYC-6 and CLYC-7 response to γ-rays, fast and thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Giaz, A.; Pellegri, L. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Camera, F., E-mail: franco.camera@mi.infn.it [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Blasi, N.; Brambilla, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Ceruti, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Million, B. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Riboldi, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Cazzaniga, C.; Gorini, G.; Nocente, M. [University of Milano Bicocca, Physics Department, Piazza della Scienza 3, 20126 Milano (Italy); Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, via Roberto Cozzi 53, 20125 Milano (Italy); Pietropaolo, A.; Pillon, M. [Associazione EURATOM-ENEA sulla Fusione ENEA C.R. Frascati, Via E. Fermi 45, 00044 Frascati, Roma (Italy); Rebai, M. [University of Milano Bicocca, Physics Department, Piazza della Scienza 3, 20126 Milano (Italy); Tardocchi, M. [Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, via Roberto Cozzi 53, 20125 Milano (Italy)

    2016-02-21

    The crystal Cs{sub 2}LiYCl{sub 6}:Ce (CLYC) is a very interesting scintillator material because of its good energy resolution and its capability to identify γ-rays and fast/thermal neutrons. The crystal Cs{sub 2}LiYCl{sub 6}:Ce contains {sup 6}Li and {sup 35}Cl isotopes, therefore, it is possible to detect thermal neutrons through the reaction {sup 6}Li(n, α)t while {sup 35}Cl ions allow to measure fast neutrons through the reactions {sup 35}Cl(n, p){sup 35}S and {sup 35}Cl(n, α){sup 32}P. In this work two CLYC 1″×1″ crystals were used: the first crystal, enriched with {sup 6}Li at 95% (CLYC-6) is ideal for thermal neutron measurements while the second one, enriched with {sup 7}Li at >99% (CLYC-7) is suitable for fast neutron measurements. The response of CLYC scintillators was measured with different PMT models: timing or spectroscopic, with borosilicate glass or quartz window. The energy resolution, the neutron-γ discrimination and the internal activity are discussed. The capability of CLYC scintillators to discriminate γ rays from neutrons was tested with both thermal and fast neutrons. The thermal neutrons were measured with both detectors, using an AmBe source. The measurements of fast neutrons were performed at the Frascati Neutron Generator facility (Italy) where a deuterium beam was accelerated on a deuterium or on a tritium target, providing neutrons of 2.5 MeV or 14.1 MeV, respectively. The different sensitivity to thermal and fast neutrons of a CLYC-6 and of a CLYC-7 was additionally studied.

  5. A feasibility study using radiochromic films for fast neutron 2D passive dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Brady, Samuel L; Fallin, Brent [Medical Physics Graduate Program, Duke University, Durham, NC 27705 (United States); Gunasingha, Rathnayaka; Yoshizumi, Terry T [Radiation Safety Division, Duke University, Durham, NC 27705 (United States); Howell, Calvin R; Crowell, Alexander S; Tonchev, Anton P [Department of Physics, Duke University, Durham, NC 27706 (United States); Dewhirst, Mark W, E-mail: yoshi003@mc.duke.ed [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States)

    2010-09-07

    The objective of this paper is threefold: (1) to establish sensitivity of XRQA and EBT radiochromic films to fast neutron exposure; (2) to develop a film response to radiation dose calibration curve and (3) to investigate a two-dimensional (2D) film dosimetry technique for use in establishing an experimental setup for a radiobiological irradiation of mice and to assess the dose to the mice in this setup. The films were exposed to a 10 MeV neutron beam via the {sup 2}H(d,n){sup 3}He reaction. The XRQA film response was a factor of 1.39 greater than EBT film response to the 10 MeV neutron beam when exposed to a neutron dose of 165 cGy. A film response-to-soft tissue dose calibration function was established over a range of 0-10 Gy and had a goodness of fit of 0.9926 with the calibration data. The 2D film dosimetry technique estimated the neutron dose to the mice by measuring the dose using a mouse phantom and by placing a piece of film on the exterior of the experimental mouse setup. The film results were benchmarked using Monte Carlo and aluminum (Al) foil activation measurements. The radiochromic film, Monte Carlo and Al foil dose measurements were strongly correlated, and the film within the mouse phantom agreed to better than 7% of the externally mounted films. These results demonstrated the potential application of radiochromic films for passive 2D neutron dosimetry.

  6. Integral test on activation cross section of tag gas nuclides using fast neutron spectrum fields

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Takafumi; Suzuki, Soju [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    Activation cross sections of tag gas nuclides, which will be used for the failed fuel detection and location in FBR plants, were evaluated by the irradiation tests in the fast neutron spectrum fields in JOYO and YAYOI. The comparison of their measured radioactivities and the calculated values using the JENDL-3.2 cross section set showed that the C/E values ranged from 0.8 to 2.8 for the calibration tests in YAYOI and that the present accuracies of these cross sections were confirmed. (author)

  7. Transient and chronic neurological complications of fast neutron radiation for adenocarcinoma of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Russell, K.J.; Laramore, G.E.; Wiens, L.W.; Griffeth, J.T.; Koh, W.J.; Griffin, B.R.; Austin-Seymour, M.M.; Griffin, T.W. (Washington Univ., Seattle, WA (USA). Lab. of Radiation Ecology); Krieger, J.N. (Washington University, Seattle (USA). Department of Urology); Davis, L.W. (Albert Einstein Coll. of Medicine, Bronx, NY (USA))

    1990-07-01

    The records of 132 patients participating in clinical trials using fast neutron (n = 94), mixed neutron and photon (n = 16), or conventional photon (n = 22) irradiation for primary management of prostatic cancer were retrospectively reviewed to assess treatment-related neurological complications. With a median follow-up of 14 months (range 1 to 101 months), 31/132 patients (26 neutron, 3 mixed beam, 2 photon) have experienced either sciatica beginning during or shortly after treatment, or diminished bladder or bowel continence that developed at a median time of 6.5 months following treatment. Sciatica responded to oral steroids and was usually self-limited, whereas sphincter dysfunction appears to be permanent. Pre-treatment risk factors for complications included a history of hypertension, diabetes, cigarette smoking or peripheral vascular disease, with 81% of affected patients having one or more risk factors compared witn 55% of unaffected patients (p = 0.01). Seven patients have moderate (5) or severe (2) residual problems, all in the cohorts receiving neutrons (6/7) or mixed beam therapy (1/7). (author). 31 refs.; 5 tabs.

  8. NeuLAND MRPC-based detector prototypes tested with fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Caesar, Christoph [GSI Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany)

    2010-07-01

    A detector for momentum measurements of high-energy neutrons in the energy range 0.2-1 GeV is being developed for the R{sup 3}B (Reactions with Relativistic Radioactive Beams) experiment at FAIR. Based on the running LAND detector at GSI, the currently pursued concept for NeuLAND is a layered structure made of iron converters and charged particle detectors. As charged particle detectors Multigap Resistive Plate Chamber (MRPC) detectors will be used. The excellent time resolution of the MRPC units will allow for a very good time-of-flight resolution of NeuLAND. The design goal for the full detector is {sigma}{sub time} <100 ps. The full NeuLAND detector will consist of about 60 layers of the basic structure (converter+MRPC), leading to a detection efficiency of close to 100% for neutrons with energies higher than 200 MeV. Prototypes built at GSI and FZD were tested using MIPs at the ELBE electron beam facility at FZD. Here we present recent results from a first irradiation of the prototypes with fast neutrons. The TSL Uppsala monoenergetic neutron beam of E{sub n}=175 MeV is well-suited for such a study. These data will serve both for the validation of the basic detection scheme and as important input to refine GEANT4 and FLUKA simulations of the final detector.

  9. Fast ultrasonic visualisation under sodium. Application to the fast neutron reactors; Visualisation ultrasonore rapide sous sodium. application aux reacteurs a neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Imbert, Ch

    1997-05-30

    The fast ultrasonic visualization under sodium is in the programme of research and development on the inspection inside the fast neutron reactors. This work is about the development of a such system of fast ultrasonic imaging under sodium, in order to improve the existing visualization systems. This system is based on the principle of orthogonal imaging, it uses two linear antennas with an important dephasing having 128 piezo-composite elements of central frequency equal to 1.6 MHz. (N.C.)

  10. Temperature Dependence of the Primary Species Yields of Liquid Water Radiolysis by 0.8-MeV Fast Neutrons

    Directory of Open Access Journals (Sweden)

    S.L. Butarbutar

    2016-04-01

    Full Text Available The yields of species such as e-aq, H•, •OH, H2 and H2O2, formed from the radiolysis of neutral liquid water by the incidence of 0.8-MeV neutrons at temperatures between 25 and 350°C, were calculated by using Monte Carlo simulations. The slowing down of these neutrons through elastic scattering produced recoil protons elastically of ~0.5057, 0.186, and 0.0684 MeV which had linear energy transfers (LETs of ~40, 67 and 76 keV/µm, respectively, at 25°C. The effects of neutron radiation can be predicted based on the contribution of those first three recoil protons by neglecting the radiation effects due to oxygen ion recoils. Then, the fast neutron yields could be estimated by summing the yields of contributing protons after corresponding weightings were used according to their energy. In this work, yields were calculated at 10-7 and 10-6 s after incidence of neutron radiation in water at the aforementioned temperature range. Overall, there is a reasonably good agreement between our calculated and existing experimental G-values for the entire temperature range. However, we proposed an hypothesis that the not very significant difference between experimental data and our calculated data is due to the different measuring time used in obtaining the experimental data as compared to the ones used in our calculation. Our computed yields for 0.8-MeV fast neutron radiation show an essentially similar temperature dependences over the range of temperature studied with 2-MeV fast neutron and low-LET radiation, but with lower values for yields of free radicals and higher values for molecular yields.

  11. Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Yoshinori, E-mail: yosakura@rri.kyoto-u.ac.jp; Tanaka, Hiroki; Kondo, Natsuko; Kinashi, Yuko; Suzuki, Minoru; Masunaga, Shinichiro; Ono, Koji; Maruhashi, Akira [Kyoto University Research Reactor Institute, Asashironishi 2-1010, Kumatori-cho, Sennan-gun, Osaka 590-0494 (Japan)

    2015-11-15

    Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % {sup 6}LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % {sup 6}LiOH solution based on the simulation results. Experimental characterization of the

  12. Recent Developments In Fast Neutron Detection And Multiplicity Counting With Verification With Liquid Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Nakae, L; Chapline, G; Glenn, A; Kerr, P; Kim, K; Ouedraogo, S; Prasad, M; Sheets, S; Snyderman, N; Verbeke, J; Wurtz, R

    2011-09-30

    For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, we used thermal neutron detectors (mainly {sup 3}He), taking advantage of the high thermal neutron interaction cross-sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics which respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production time-scales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array, and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

  13. Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

    Science.gov (United States)

    Nakae, L. F.; Chapline, G. F.; Glenn, A. M.; Kerr, P. L.; Kim, K. S.; Ouedraogo, S. A.; Prasad, M. K.; Sheets, S. A.; Snyderman, N. J.; Verbeke, J. M.; Wurtz, R. E.

    2011-12-01

    For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly 3He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of μs) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of 3He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

  14. From resonantly interacting fermions with effective range to neutron matter

    CERN Document Server

    Lacroix, Denis

    2016-01-01

    A density functional theory is proposed for strongly interacting fermions with arbitrary large negative scattering length. The functional has only two parameters that are directly fixed to reproduce the universal properties of unitary gas: the so-called "Bertsch parameter" $\\xi_0$ and a parameter $\\eta_e$ related to the possible influence of the effective range $r_e$ at infinite scattering length $a$. Using most recent quantum Monte-Carlo (QMC) estimates of these two parameters, it is shown that the functional properly reproduces the experimental measurements of interacting Fermi systems not only at unitarity but also away from this limit over a wide range of $(ak_F)^{-1}$ values. The functional is applied to obtain an expression of the Tan's contact parameter including the effect of $r_e$. Application is finally made to neutron matter. It is shown that most recent QMC results are well reproduced.

  15. Conceptual study of a compact accelerator-driven neutron source for radioisotope production, boron neutron capture therapy and fast neutron therapy

    CERN Document Server

    Angelone, M; Rollet, S

    2002-01-01

    The feasibility of a compact accelerator-driven device for the generation of neutron spectra suitable for isotope production by neutron capture, boron neutron capture therapy and fast neutron therapy, is analyzed by Monte Carlo simulations. The device is essentially an extension of the activator proposed by Rubbia left bracket CERN/LHC/97-04(EET) right bracket , in which fast neutrons are diffused and moderated within a properly sized lead block. It is shown that by suitable design of the lead block, as well as of additional elements of moderating and shielding materials, one can generate and exploit neutron fluxes with the spectral features required for the above applications. The linear dimensions of the diffusing-moderating device can be limited to about 1 m. A full-scale device for all the above applications would require a fast neutron source of about 10**1**4 s**-**1, which could be produced by a 1 mA, 30 MeV proton beam impinging on a Be target. The concept could be tested at the Frascati Neutron Gener...

  16. Fast Radio Bursts from the Inspiral of Double Neutron Stars

    CERN Document Server

    Wang, Jie-Shuang; Wu, Xue-Feng; Dai, Zi-Gao; Wang, Fa-Yin

    2016-01-01

    Recently, a fading radio transient after the fast radio burst (FRB) 150418 was discovered and its cosmological redshift was measured by Keane et al. (2016}. This afterglow lasting $\\sim 6$ days is largely in agreement with the radio afterglow of a short gamma-ray burst (SGRB), and thus the double neutron star (NS-NS) merger model for this FRB is favored. Here we suggest that an FRB could originate from the magnetic interaction between two NSs during their inspiral, within the framework of a unipolar inductor model. In this model, an electromotive force is induced on one NS to accelerate electrons. We show that coherent curvature radiation from these electrons in the magnetosphere of the other NS is responsible for the observed FRB signal, that is, the characteristic luminosity, duration, frequency and event rate of an FRB can be well understood. In addition, we discuss several implications of this model, including possible associations of FRBs with SGRB afterglows and gravitational wave events.

  17. The preliminary results of fast neutron flux measurements in the DULB laboratory at Baksan

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Shikhin, A A; Yants, V E; Zaborskaia, O S; Klimenko, A A; Osetrov, S B; Smolnikov, A A; Vasilev, S I

    2000-01-01

    One of the main sources of a background in underground physics experiments (such as the investigation of solar neutrino flux, neutrino oscillations, neutrinoless double beta decay, and the search for annual and daily Cold Dark Matter particle flux modulation) are fast neutrons originating from the surrounding rocks. The measurements of fast neutron flux in the new DULB Laboratory situated at a depth of 4900 m w.e. in the Baksan Neutrino Observatory have been performed. The relative neutron shielding properties of several commonly available natural materials were investigated too. The preliminary results obtained with a high-sensitive fast neutron spectrometer at the level of sensitivity of about 10^(-7) neutron/ (cm^2 sec) are presented and discussed.

  18. Detection of fast neutrons from shielded nuclear materials using a semiconductor alpha detector.

    Science.gov (United States)

    Pöllänen, R; Siiskonen, T

    2014-08-01

    The response of a semiconductor alpha detector to fast (>1 MeV) neutrons was investigated by using measurements and simulations. A polyethylene converter was placed in front of the detector to register recoil protons generated by elastic collisions between neutrons and hydrogen nuclei of the converter. The developed prototype equipment was tested with shielded radiation sources. The low background of the detector and insensitivity to high-energy gamma rays above 1 MeV are advantages when the detection of neutron-emitting nuclear materials is of importance. In the case of a (252)Cf neutron spectrum, the intrinsic efficiency of fast neutron detection was determined to be 2.5×10(-4), whereas three-fold greater efficiency was obtained for a (241)AmBe neutron spectrum.

  19. Distinguishing Pu Metal from Pu Oxide and Determining alpha-ratio using Fast Neutron Counting

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, J. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chapline, G. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nakae, L. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Prasad, M. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sheets, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Snyderman, N. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-01-07

    We describe a new method for determining the ratio of the rate of (α, n) source neutrons to the rate of spontaneous fission neutrons, the so called α-ratio. This method is made possible by fast neutron counting with liquid scintillator detectors, which can determine the shape of the fast neutron spectrum. The method utilizes the spectral difference between fission spectrum neutrons from Pu metal and the spectrum of (α, n) neutrons from PuO2. Our method is a generalization of the Cifarelli-Hage method for determining keff for fissile assemblies, and also simultaneously determines keff along with the α-ratio.

  20. Fast Neutron Induced Autophagy Leads To Necrosis In Glioblastoma Multiforme Cells

    Science.gov (United States)

    Yasui, Linda; Gladden, Samantha; Andorf, Christine; Kroc, Thomas

    2011-06-01

    Fast neutrons are highly effective at killing glioblastoma multiforme (GBM), U87 and U251 cells. The mode of cell death was investigated using transmission electron microscopy (TEM) to identify the fraction of irradiated U87 or U251 cells having morphological features of autophagy and/or necrosis. U87 or U251 cells were irradiated with 2 Gy fast neturons or 10 Gy γ rays. A majority of U87 and U251 cells exhibit features of cell death with autophagy after irradiation with either 10 Gy γ rays or 2 Gy fast neutrons. Very few γ irradiated cells had features of necrosis (U87 or U251 cell samples processed for TEM 1 day after 10 Gy γ irradiation). In contrast, a significant increase was observed in necrotic U87 and U251 cells irradiated with fast neutrons. These results show a greater percentage of cells exhibit morphological evidence of necrosis induced by a lower dose of fast neutron irradiation compared to γ irradiation. Also, the evidence of necrosis in fast neutron irradiated U87 and U251 cells occurs in a background of autophagy. Since autophagy is observed before necrosis, autophagy may play a role in signaling programmed necrosis in fast neutron irradiated U87 and U251 cells.

  1. Scaling functions of two-neutron separation energies of $^{20}C$ with finite range potentials

    CERN Document Server

    Shalchi, M A; Yamashita, M T; Tomio, Lauro; Frederico, T

    2015-01-01

    The behaviour of an Efimov excited state is studied within a three-body Faddeev formalism for a general neutron-neutron-core system, where neutron-core is bound and neutron-neutron is unbound, by considering zero-ranged as well as finite-ranged two-body interactions. For the finite-ranged interactions we have considered a one-term separable Yamaguchi potential. The main objective is to study range corrections in a scaling approach, with focus in the exotic carbon halo nucleus $^{20}C$.

  2. Scaling functions of two-neutron separation energies of 20C with finite range potentials

    Science.gov (United States)

    Shalchi, M. A.; Hadizadeh, M. R.; Yamashita, M. T.; Tomio, Lauro; Frederico, T.

    2016-03-01

    The behaviour of an Efimov excited state is studied within a three-body Faddeev formalism for a general neutron-neutron-core system, where neutron-core is bound and neutron-neutron is unbound, by considering zero-ranged as well as finite-ranged two-body interactions. For the finite-ranged interactions we have considered a one-term separable Yamaguchi potential. The main objective is to study range corrections in a scaling approach, with focus in the exotic carbon halo nucleus 20C.

  3. Scaling functions of two-neutron separation energies of 20C with finite range potentials

    Directory of Open Access Journals (Sweden)

    Shalchi M. A.

    2016-01-01

    Full Text Available The behaviour of an Efimov excited state is studied within a three-body Faddeev formalism for a general neutron-neutron-core system, where neutron-core is bound and neutron-neutron is unbound, by considering zero-ranged as well as finite-ranged two-body interactions. For the finite-ranged interactions we have considered a one-term separable Yamaguchi potential. The main objective is to study range corrections in a scaling approach, with focus in the exotic carbon halo nucleus 20C.

  4. A fast-neutron generator for experiments; Um dispositivo gerador de neutrons rapidos para experimentacao

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Charles F.; Souza, Manuel Jorge M.T. de; Campos, Tarcisio P.R. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares]. E-mail: campos@nuclear.ufmg.br

    2005-07-01

    The present article presents an irradiation device of fast neutrons generated by sealed sources of AmBe, placed diametrically opposed to a central channel. The paper addresses the project, the shield calculations using the nuclear code MCNP5, and radioprotection issues. Considerations of the assembly of the device will be presented. The device is in a licensing phase. A cylinder of 30 cm diameter and 200 cm length are positioned buried 200 cm deep, whose opening is in the level of the floor Six sealed sources are available for the load of the irradiator. The sources will be positioned inside of the irradiator, receiving a double cast, a polyethylene one and another made of a steel tube. In the bottom and top of the cylinder there are paraffin shielding and in the center a central channel exists for lifting down samples to the irradiation position. In the central channel of this irradiator, a guide tube holds safely the sample close to 60 mm at center distance from sources, diametrically placed. The system is built-in into the soil, with the opening in the floor and all stamped against humidity. The sample's space to be irradiated has 20cm{sup 3} and it receives irradiation of fast to thermal neutrons. At vertical level, the sources will be shielded with 120 cm of boronate paraffin. A solid cylinder of 10 cm of diameter is positioned internally in the irradiator. The cylinder receives a restraint so that it cannot be removed unaware. In the half middle of the cylinder an opening of 8 cm length exists, in the form of a camera. Puling over the cylinder in a meter height liberates the camera at the level of the floor for placement of samples, at the same time in that shields the hole with a meter of boronate paraffin. The sample is placed inside of the camera of steel. After going down the cylinder at level of sources the sample is irradiated. Radioprotection aspects will be presented. The neutron flux at camera position is close to 10{sup 8}n/cm{sup 2}.seg. at 6

  5. Analysis of Some Egyptian Cosmetic Samples by Fast Neutron Activation Analysis

    CERN Document Server

    Medhat, M E; Fayez-Hassan, M

    2001-01-01

    A description of D-T neutron generator (NG) is presented. This generator can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. In our work, the concentration of the elements Na, Mg, Al, Si, K, Cl, Ca and Fe, were determined in two domestic brands of face powder by using 14 MeV neutron activation analysis.

  6. Neutronic calculation of fast reactors by the EUCLID/V1 integrated code

    Science.gov (United States)

    Koltashev, D. A.; Stakhanova, A. A.

    2017-01-01

    This article considers neutronic calculation of a fast-neutron lead-cooled reactor BREST-OD-300 by the EUCLID/V1 integrated code. The main goal of development and application of integrated codes is a nuclear power plant safety justification. EUCLID/V1 is integrated code designed for coupled neutronics, thermomechanical and thermohydraulic fast reactor calculations under normal and abnormal operating conditions. EUCLID/V1 code is being developed in the Nuclear Safety Institute of the Russian Academy of Sciences. The integrated code has a modular structure and consists of three main modules: thermohydraulic module HYDRA-IBRAE/LM/V1, thermomechanical module BERKUT and neutronic module DN3D. In addition, the integrated code includes databases with fuel, coolant and structural materials properties. Neutronic module DN3D provides full-scale simulation of neutronic processes in fast reactors. Heat sources distribution, control rods movement, reactivity level changes and other processes can be simulated. Neutron transport equation in multigroup diffusion approximation is solved. This paper contains some calculations implemented as a part of EUCLID/V1 code validation. A fast-neutron lead-cooled reactor BREST-OD-300 transient simulation (fuel assembly floating, decompression of passive feedback system channel) and cross-validation with MCU-FR code results are presented in this paper. The calculations demonstrate EUCLID/V1 code application for BREST-OD-300 simulating and safety justification.

  7. Characterization of the fast neutron irradiation facility of the Portuguese Research Reactor after core conversion.

    Science.gov (United States)

    Marques, J G; Sousa, M; Santos, J P; Fernandes, A C

    2011-08-01

    The fast neutron irradiation facility of the Portuguese Research Reactor was characterized after the reduction in uranium enrichment and rearrangement of the core configuration. In this work we report on the determination of the hardness parameter and the 1MeV equivalent neutron flux along the facility, in the new irradiation conditions, following ASTM E722 standard.

  8. The effect of biological shielding on fast neutron and photon transport in the VVER-1000 mock-up model placed in the LR-0 reactor.

    Science.gov (United States)

    Košťál, Michal; Cvachovec, František; Milčák, Ján; Mravec, Filip

    2013-05-01

    The paper is intended to show the effect of a biological shielding simulator on fast neutron and photon transport in its vicinity. The fast neutron and photon fluxes were measured by means of scintillation spectroscopy using a 45×45 mm(2) and a 10×10 mm(2) cylindrical stilbene detector. The neutron spectrum was measured in the range of 0.6-10 MeV and the photon spectrum in 0.2-9 MeV. The results of the experiment are compared with calculations. The calculations were performed with various nuclear data libraries.

  9. Fast-neutron spectrometry using a ³He ionization chamber and digital pulse shape analysis.

    Science.gov (United States)

    Chichester, D L; Johnson, J T; Seabury, E H

    2012-08-01

    Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type (3)He ionization chamber to measure the fast-neutron spectra of a deuterium-deuterium electronic neutron generator, a bare (252)Cf spontaneous fission neutron source, and of the transmitted fast neutron spectra of a (252)Cf source attenuated by water, graphite, liquid nitrogen, and magnesium. Rise-time dPSA has been employed using the common approach for analyzing n +(3)He→(1)H+(3)H ionization events and improved to account for wall-effect and pile-up events, increasing the fidelity of these measurements. Simulations have been performed of the different experimental arrangements and compared with the measurements, demonstrating general agreement between the dPSA-processed fast-neutron spectra and predictions. The fast-neutron resonance features of the attenuation cross sections of the attenuating materials are clearly visible within the resolution limits of the electronics used for the measurements, and the potential applications of high-resolution fast-neutron spectrometry for nuclear nonproliferation and safeguards measurements are discussed.

  10. MCNPX Monte Carlo simulations of particle transport in SiC semiconductor detectors of fast neutrons

    Science.gov (United States)

    Sedlačková, K.; Zat'ko, B.; Šagátová, A.; Pavlovič, M.; Nečas, V.; Stacho, M.

    2014-05-01

    The aim of this paper was to investigate particle transport properties of a fast neutron detector based on silicon carbide. MCNPX (Monte Carlo N-Particle eXtended) code was used in our study because it allows seamless particle transport, thus not only interacting neutrons can be inspected but also secondary particles can be banked for subsequent transport. Modelling of the fast-neutron response of a SiC detector was carried out for fast neutrons produced by 239Pu-Be source with the mean energy of about 4.3 MeV. Using the MCNPX code, the following quantities have been calculated: secondary particle flux densities, reaction rates of elastic/inelastic scattering and other nuclear reactions, distribution of residual ions, deposited energy and energy distribution of pulses. The values of reaction rates calculated for different types of reactions and resulting energy deposition values showed that the incident neutrons transfer part of the carried energy predominantly via elastic scattering on silicon and carbon atoms. Other fast-neutron induced reactions include inelastic scattering and nuclear reactions followed by production of α-particles and protons. Silicon and carbon recoil atoms, α-particles and protons are charged particles which contribute to the detector response. It was demonstrated that although the bare SiC material can register fast neutrons directly, its detection efficiency can be enlarged if it is covered by an appropriate conversion layer. Comparison of the simulation results with experimental data was successfully accomplished.

  11. Identification of the fast and thermal neutron characteristics of transuranic waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Storm, B.H. Jr.; Bramblett, R.L. [Lockheed Martin Specialty Components, Largo, FL (United States); Hensley, C. [Oak Ridge National Lab., TN (United States)

    1997-11-01

    Fissile and spontaneously fissioning material in transuranic waste drums can be most sensitively assayed using an active and passive neutron assay system such as the Active Passive Neutron Examination and Assay. Both the active and the passive assays are distorted by the presence of the waste matrix and containerization. For accurate assaying, this distortion must be characterized and accounted for. An External Matrix Probe technique has been developed that accomplishes this task. Correlations between in-drum neutron flux measurements and monitors in the Active Passive Neutron Examination and Assay chamber with various matrix materials provide a non-invasive means of predicting the thermal neutron flux in waste drums. Similarly, measures of the transmission of fast neutrons emitted from sources in the drum. Results obtained using the Lockheed Martin Specialty Components Active Passive Neutron Examination and Assay system are discussed. 12 figs., 1 tab.

  12. Measurements of prompt gamma-rays from fast-neutron induced fission with the LICORNE directional neutron source

    CERN Document Server

    Wilson, J N; Halipre, P; Oberstedt, S; Oberstedt, A

    2014-01-01

    At the IPN Orsay we have developed a unique, directional, fast neutron source called LICORNE, intended initially to facilitate prompt fission gamma measurements. The ability of the IPN Orsay tandem accelerator to produce intense beams of $^7$Li is exploited to produce quasi-monoenergetic neutrons between 0.5 - 4 MeV using the p($^7$Li,$^7$Be)n inverse reaction. The available fluxes of up to 7 × 10$^7$ neutrons/second/steradian for the thickest hydrogen-rich targets are comparable to similar installations, but with two added advantages: (i) The kinematic focusing produces a natural neutron beam collimation which allows placement of gamma detectors adjacent to the irradiated sample unimpeded by source neutrons. (ii) The background of scattered neutrons in the experimental hall is drastically reduced. The dedicated neutron converter was commissioned in June 2013. Some preliminary results from the first experiment using the LICORNE neutron source at the IPN Orsay are presented. Prompt fission gamma rays from fas...

  13. Fission signal detection using helium-4 gas fast neutron scintillation detectors

    Science.gov (United States)

    Lewis, J. M.; Kelley, R. P.; Murer, D.; Jordan, K. A.

    2014-07-01

    We demonstrate the unambiguous detection of the fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium fusion neutron generator and a high pressure 4He gas fast neutron scintillation detector. The energy deposition by individual neutrons is quantified, and energy discrimination is used to differentiate the induced fission neutrons from the mono-energetic interrogation neutrons. The detector can discriminate between different incident neutron energies using pulse height discrimination of the slow scintillation component of the elastic scattering interaction between a neutron and the 4He atom. Energy histograms resulting from this data show the buildup of a detected fission neutron signal at higher energies. The detector is shown here to detect a unique fission neutron signal from a natural uranium sample during active interrogation with a (d, d) neutron generator. This signal path has a direct application to the detection of shielded nuclear material in cargo and air containers. It allows for continuous interrogation and detection while greatly minimizing the potential for false alarms.

  14. A new fast neutron collar for safeguards inspection measurements of fresh low enriched uranium fuel assemblies containing burnable poison rods

    Science.gov (United States)

    Evans, Louise G.; Swinhoe, Martyn T.; Menlove, Howard O.; Schwalbach, Peter; Baere, Paul De; Browne, Michael C.

    2013-11-01

    Safeguards inspection measurements must be performed in a timely manner in order to detect the diversion of significant quantities of nuclear material. A shorter measurement time can increase the number of items that a nuclear safeguards inspector can reliably measure during a period of access to a nuclear facility. In turn, this improves the reliability of the acquired statistical sample, which is used to inform decisions regarding compliance. Safeguards inspection measurements should also maintain independence from facility operator declarations. Existing neutron collars employ thermal neutron interrogation for safeguards inspection measurements of fresh fuel assemblies. A new fast neutron collar has been developed for safeguards inspection measurements of fresh low-enriched uranium (LEU) fuel assemblies containing gadolinia (Gd2O3) burnable poison rods. The Euratom Fast Collar (EFC) was designed with high neutron detection efficiency to make a fast (Cd) mode measurement viable whilst meeting the high counting precision and short assay time requirements of the Euratom safeguards inspectorate. A fast mode measurement reduces the instrument sensitivity to burnable poison rod content and therefore reduces the applied poison correction, consequently reducing the dependence on the operator declaration of the poison content within an assembly. The EFC non-destructive assay (NDA) of typical modern European pressurized water reactor (PWR) fresh fuel assembly designs have been simulated using Monte Carlo N-particle extended transport code (MCNPX) simulations. Simulations predict that the EFC can achieve 2% relative statistical uncertainty on the doubles neutron counting rate for a fast mode measurement in an assay time of 600 s (10 min) with the available 241AmLi (α,n) interrogation source strength of 5.7×104 s-1. Furthermore, the calibration range of the new collar has been extended to verify 235U content in variable PWR fuel designs in the presence of up to 32

  15. Cisplatin enhances the cytotoxicity of fast neutrons in a murine lymphoma cell line

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, B.; Benzina, S.; Ganansia-Leymarie, V. [Hopitaux Universitaires, Lab. de Cancerologie Experimentale et de Radiobiologie, Strasbourg CEDEX (France); Denis, J.M. [Universite Catholique de Louvain (UCL-RBNT), Lab. de Radiobiologie et de Radioprotection, Faculte de Medecine, Bruxelles (Belgium); Bergerat, J.P.; Dufour, P. [Hopitaux Universitaires, Lab. de Cancerologie Experimentale et de Radiobiologie, Strasbourg CEDEX (France); Gueulette, J. [Universite Catholique de Louvain (UCL-RBNT), Lab. de Radiobiologie et de Radioprotection, Faculte de Medecine, Bruxelles (Belgium); Bischoff, P. [Hopitaux Universitaires, Lab. de Cancerologie Experimentale et de Radiobiologie, Strasbourg CEDEX (France)]. E-mail: Pierre.Bischoff@ircad.u-strasbg.fr

    2004-02-01

    The utilization of high linear energy transfer (LET) radiations, such as fast neutrons or carbon ions (hadrontherapy), offers promising perspectives in radiotherapy. While it is well known that by combining radiotherapy and chemotherapy, important therapeutic advantages can be obtained to cure cancer, there have been, so far, very few investigations on the effects of treatments combining an irradiation with high-LET particles and cancer drugs. The present study was therefore undertaken to examine the effects of exposure to 65 MeV fast neutrons combined with cisplatin in a murine T cell lymphoma (RDM4) in vitro. The cells were irradiated at doses ranging from 2 to 8 Gy without or with addition of cisplatin shortly before the irradiation, at concentrations between 0.3 and 12.5 {mu}M. These treatments were applied concomitantly. Proliferation and apoptosis were assessed at different time intervals thereafter. The combination of irradiation with cisplatin was found to be more cytotoxic than either treatment alone. Furthermore, the cytotoxicity induced by this cotreatment resulted not only from apoptosis but also from other forms of cell death. (author)

  16. Fast neutron-induced damage in INTEGRAL n-type HPGe detectors

    CERN Document Server

    Borrel, V; Albernhe, F; Frabel, P; Cordier, B; Tauzin, G; Crespin, S; Coszach, R; Denis, J M; Leleux, P

    1999-01-01

    Several INTEGRAL n-type HPGe detectors have been irradiated by fast neutrons and their degradation studied through the analysis of line shapes. The availability of three different fast neutron beams (5, 16 and 6-70 MeV) allowed a quantitative analysis of the importance of the neutron energy on the amount of damage. A comparison is made with the degradation induced by high-energy proton irradiations. Transient effects on the measured resolution are reported after high voltage cut-off on degraded detectors.

  17. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    Energy Technology Data Exchange (ETDEWEB)

    Guo, J. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Buecherl, T. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Zou, Y., E-mail: zouyubin@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Guo, Z. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China)

    2011-09-21

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  18. Inelastic scattering of fast neutrons on Fe-56; Inelastische Streuung schneller Neutronen an {sup 56}Fe

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, Roland

    2014-11-24

    The relevant reaction cross sections for the nuclear transmutation will be measured at the neutron flight time facility nELBE in Dresden-Rossendorf. Transmutation by fast neutron irradiation is supposed to reduce the radiotoxicity of high-level radioactive wastes. The thesis is aimed to measure the inelastic neutron scattering cross sections of Fe-56 using a new double flight-time method. With combined plastic and BaF2 scintillation detectors for the first time the emitted neutrons and photons are observed in coincidence.

  19. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    Energy Technology Data Exchange (ETDEWEB)

    Habob, Moinul

    2005-12-15

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design.

  20. Dose estimations of fast neutrons from a nuclear reactor by micronuclear yields in onion seedlings.

    Science.gov (United States)

    Fujikawa, K; Endo, S; Itoh, T; Yonezawa, Y; Hoshi, M

    1999-12-01

    Irradiations of onion seedlings with fission neutrons from bare, Pb-moderated, and Fe-moderated 252Cf sources induced micronuclei in the root-tip cells at similar rates. The rate per cGy averaged for the three sources, , was 19 times higher than rate induced by 60Co gamma-rays. When neutron doses, Dn, were estimated from frequencies of micronuclei induced in onion seedlings after exposure to neutron-gamma mixed radiation from a 1 W nuclear reactor, using the reciprocal of as conversion factor, resulting Dn values agreed within 10% with doses measured with paired ionizing chambers. This excellent agreement was achieved by the high sensitivity of the onion system to fast neutrons relative to gamma-rays and the high contribution of fast neutrons to the total dose of mixed radiation in the reactor's field.

  1. Fast neutron flux analyzer with real-time digital pulse shape discrimination

    Science.gov (United States)

    Ivanova, A. A.; Zubarev, P. V.; Ivanenko, S. V.; Khilchenko, A. D.; Kotelnikov, A. I.; Polosatkin, S. V.; Puryga, E. A.; Shvyrev, V. G.; Sulyaev, Yu. S.

    2016-08-01

    Investigation of subthermonuclear plasma confinement and heating in magnetic fusion devices such as GOL-3 and GDT at the Budker Institute (Novosibirsk, Russia) requires sophisticated equipment for neutron-, gamma- diagnostics and upgrading data acquisition systems with online data processing. Measurement of fast neutron flux with stilbene scintillation detectors raised the problem of discrimination of the neutrons (n) from background cosmic particles (muons) and neutron-induced gamma rays (γ). This paper describes a fast neutron flux analyzer with real-time digital pulse-shape discrimination (DPSD) algorithm FPGA-implemented for the GOL-3 and GDT devices. This analyzer was tested and calibrated with the help of 137Cs and 252Cf radiation sources. The Figures of Merit (FOM) calculated for different energy cuts are presented.

  2. Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

    CERN Document Server

    Davis, John R; Vetter, Kai

    2016-01-01

    In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. The expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. Three areas analyzed in San Francisco, Downtown Oakland, and Berkeley all demonstrated a suppression in the backg...

  3. Fast-Neutron Spectrometry Using a 3He Ionization Chamber and Digital Pulse Shape Analysis

    Energy Technology Data Exchange (ETDEWEB)

    D. L. Chichester; J. T. Johnson; E. H. Seabury

    2010-05-01

    Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type 3He proportional counter to measure the fast neutron spectra of bare 252Cf and 241AmBe neutron sources. Measurements have also been made to determine the attenuated fast neutron spectra of 252Cf shielded by several materials including water, graphite, liquid nitrogen, magnesium, and tungsten. Rise-time dPSA has been employed using the common rise-time approach for analyzing n +3He ? 1H + 3H ionization events and a new approach has been developed to improve the fidelity of these measurements. Simulations have been performed for the different experimental arrangements and are compared, demonstrating general agreement between the dPSA processed fast neutron spectra and predictions.

  4. Real-time detection of fast and thermal neutrons in radiotherapy with CMOS sensors

    Science.gov (United States)

    Arbor, Nicolas; Higueret, Stephane; Elazhar, Halima; Combe, Rodolphe; Meyer, Philippe; Dehaynin, Nicolas; Taupin, Florence; Husson, Daniel

    2017-03-01

    The peripheral dose distribution is a growing concern for the improvement of new external radiation modalities. Secondary particles, especially photo-neutrons produced by the accelerator, irradiate the patient more than tens of centimeters away from the tumor volume. However the out-of-field dose is still not estimated accurately by the treatment planning softwares. This study demonstrates the possibility of using a specially designed CMOS sensor for fast and thermal neutron monitoring in radiotherapy. The 14 microns-thick sensitive layer and the integrated electronic chain of the CMOS are particularly suitable for real-time measurements in γ/n mixed fields. An experimental field size dependency of the fast neutron production rate, supported by Monte Carlo simulations and CR-39 data, has been observed. This dependency points out the potential benefits of a real-time monitoring of fast and thermal neutron during beam intensity modulated radiation therapies.

  5. Removal cross sections and total mass attenuation coefficients of fast neutrons and gamma rays for steel

    CERN Document Server

    Elsayed, A A

    2003-01-01

    The present work deals with the study of the attenuation properties and determination of the cross sections of fast neutrons and gamma rays for structure steel used in different applications in nuclear power plants, particle accelerators, research reactors and different radiation attenuation fields. Investigation has been performed by measuring the transmitted fast neutron and gamma ray spectra behind cylindrical samples of steel (rho=7.87 gem sup - sup 3) of different thicknesses. A reactor collimated beam and neutron - gamma spectrometer with stiblbene scintillator were used for measurements. The pluse shape disriminate technique based on zero cross over method was used to discriminate between neutron and gamma ray pulses. Effective removal cross-section (sigma sub R) and total mass attenuation coefficient (mu) of neureons and gamma rays have been achieved using the attenuation relations. Microscopic removal cross sections sigma sup 9 sup 8 and mass removal cross sections sigma sub R sub / subrho of fast ne...

  6. A study of possibility to design a fast neutron spectrometer based on the organic scintillator with surrounding materials

    Directory of Open Access Journals (Sweden)

    Avdić Senada

    2014-01-01

    Full Text Available This paper deals with the design of a novel spectrometer of fast neutrons in nuclear safeguards applications based on the liquid organic scintillator EJ-309 with materials of different thickness surrounding the detector. The investigation was performed on the simulated data obtained by the MCNPX-PoliMi numerical code based on the Monte Carlo method. Among the various materials (polyethylene, iron, aluminum, and graphite investigated as layers around the scintillator, polyethylene and iron have shown the most promising characteristics for evaluation of fast neutron energy spectra. The simulated pulse height distributions were summed up for each energy bin in the neutron energy range between 1 MeV and 15 MeV in order to obtain better counting statistics. The unfolded results for monoenergetic neutron sources obtained by a first order of Tikhonov regularization and non-linear neural network show very good agreement with the reference data while the evaluated spectra of neutron sources continuous in energy follow the trend of the reference spectra. The possible advantages of a novel spectrometer include a less number of input data for processing and a less sensitivity to the noise compared to the scintillation detector without surrounding materials.

  7. Reactions with fast radioactive beams of neutron-rich nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Aumann, T. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)

    2005-11-01

    The neutron dripline has presently been reached only for the lightest nuclei up to the element oxygen. In this region of light neutron-rich nuclei, scattering experiments are feasible even for dripline nuclei by utilizing high-energy secondary beams produced by fragmentation. In the present article, reactions of high-energy radioactive beams will be exemplified using recent experimental results mainly derived from measurements of breakup reactions performed at the LAND and FRS facilities at GSI and at the S800 spectrometer at the NSCL. Nuclear and electromagnetically induced reactions allow probing different aspects of nuclear structure at the limits of stability related to the neutron-proton asymmetry and the weak binding close to the dripline. Properties of the valence-neutron wave functions are studied in the one-neutron knockout reaction, revealing the changes of shell structure when going from the beta-stability line to more asymmetric loosely bound neutron-rich systems. The vanishing of the N=8 shell gap for neutron-rich systems like {sup 11}Li and {sup 12}Be, or the new closed N=14, 16 shells for the oxygen isotopes are examples. The continuum of weakly bound nuclei and halo states can be studied by inelastic scattering. The dipole response, for instance, is found to change dramatically when going away from the valley of stability. A redistribution of the dipole strength towards lower excitation energies is observed for neutron-rich nuclei, which partly might be due to a new collective excitation mode related to the neutron-proton asymmetry. Halo nuclei in particular show strong dipole transitions to the continuum at the threshold, being directly related to the ground-state properties of the projectile. Finally, an outlook on future experimental prospects is given. (orig.)

  8. First measurement of low intensity fast neutron background from rock at the Boulby Underground Laboratory

    CERN Document Server

    Tziaferi, E; Kudryavtsev, V A; Lerner, R; Lightfoot, P K; Paling, S M; Robinson, M; Spooner, N J C

    2006-01-01

    A technique to measure low intensity fast neutron flux has been developed. The design, calibrations, procedure for data analysis and interpretation of the results are discussed in detail. The technique has been applied to measure the neutron background from rock at the Boulby Underground Laboratory, a site used for dark matter and other experiments, requiring shielding from cosmic ray muons. The experiment was performed using a liquid scintillation detector. A 6.1 litre volume stainless steel cell was filled with an in-house made liquid scintillator loaded with Gd to enhance neutron capture. A two-pulse signature (proton recoils followed by gammas from neutron capture) was used to identify the neutron events from much larger gamma background from PMTs. Suppression of gammas from the rock was achieved by surrounding the detector with high-purity lead and copper. Calibrations of the detector were performed with various gamma and neutron sources. Special care was taken to eliminate PMT afterpulses and correlated...

  9. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    CERN Document Server

    Chen, Yonghao; Lei, Jiarong; An, Li; Zhang, Xiaodong; Shao, Jianxiong; Zheng, Pu; Wang, Xinhua

    2013-01-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  10. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    Science.gov (United States)

    Chen, YongHao; Chen, XiMeng; Lei, JiaRong; An, Li; Zhang, XiaoDong; Shao, JianXiong; Zheng, Pu; Wang, XinHua

    2014-10-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of 241Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of 241Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded 241Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  11. Fast Neutron Dosimeter for the Space Environment Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Secondary neutrons make a significant contribution to the total absorbed dose received by space crews during long duration space missions However, only a limited...

  12. Fast neutron spectroscopy with tensioned metastable fluid detectors

    Science.gov (United States)

    Grimes, T. F.; Taleyarkhan, R. P.

    2016-09-01

    This paper describes research into development of a rapid-turnaround, neutron-spectroscopy capable (gamma-beta blind), high intrinsic efficiency sensor system utilizing the tensioned metastable fluid detector (TMFD) architecture. The inability of prevailing theoretical models (developed successfully for the classical bubble chamber) to adequately predict detection thresholds for tensioned metastable fluid conditions is described. Techniques are presented to overcome these inherent shortcomings, leading thereafter, to allow successful neutron spectroscopy using TMFDs - via the newly developed Single Atom Spectroscopy (SAS) approach. SAS also allows for a unique means for rapidly determining neutron energy thresholds with TMFDs. This is accomplished by simplifying the problem of determining Cavitation Detection Events (CDEs) arising from neutron interactions with one in which several recoiling atom species contribute to CDEs, to one in which only one dominant recoil atom need be considered. The chosen fluid is Heptane (C7H16) for which only recoiling C atoms contribute to CDEs. Using the SAS approach, the threshold curve for Heptane was derived using isotope neutron source data, and then validated against experiments with mono-energetic (2.45/14 MeV) neutrons from D-D and D-T accelerators. Thereafter the threshold curves were used to produce the response matrix for various geometries. The response matrices were in turn combined with experimental data to recover the continuous spectra of fission (Cf-252) and (α,n) Pu-Be isotopic neutron sources via an unfolding algorithm. A generalized algorithm is also presented for performing neutron spectroscopy using any other TMFD fluid that meets the SAS approach assumptions.

  13. Fast neutron spectroscopy with tensioned metastable fluid detectors

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, T.F.; Taleyarkhan, R.P., E-mail: rusi@purdue.edu

    2016-09-11

    This paper describes research into development of a rapid-turnaround, neutron-spectroscopy capable (gamma-beta blind), high intrinsic efficiency sensor system utilizing the tensioned metastable fluid detector (TMFD) architecture. The inability of prevailing theoretical models (developed successfully for the classical bubble chamber) to adequately predict detection thresholds for tensioned metastable fluid conditions is described. Techniques are presented to overcome these inherent shortcomings, leading thereafter, to allow successful neutron spectroscopy using TMFDs – via the newly developed Single Atom Spectroscopy (SAS) approach. SAS also allows for a unique means for rapidly determining neutron energy thresholds with TMFDs. This is accomplished by simplifying the problem of determining Cavitation Detection Events (CDEs) arising from neutron interactions with one in which several recoiling atom species contribute to CDEs, to one in which only one dominant recoil atom need be considered. The chosen fluid is Heptane (C{sub 7}H{sub 16}) for which only recoiling C atoms contribute to CDEs. Using the SAS approach, the threshold curve for Heptane was derived using isotope neutron source data, and then validated against experiments with mono-energetic (2.45/14 MeV) neutrons from D-D and D-T accelerators. Thereafter the threshold curves were used to produce the response matrix for various geometries. The response matrices were in turn combined with experimental data to recover the continuous spectra of fission (Cf-252) and (α,n) Pu–Be isotopic neutron sources via an unfolding algorithm. A generalized algorithm is also presented for performing neutron spectroscopy using any other TMFD fluid that meets the SAS approach assumptions.

  14. Fast O(1) bilateral filtering using trigonometric range kernels

    CERN Document Server

    Chaudhury, Kunal Narayan; Unser, Michael

    2011-01-01

    It is well-known that spatial averaging can be realized (in space or frequency domain) using algorithms whose complexity does not depend on the size or shape of the filter. These fast algorithms are generally referred to as constant-time or O(1) algorithms in the image processing literature. Along with the spatial filter, the edge-preserving bilateral filter [bilateralFilter] involves an additional range kernel. This is used to restrict the averaging to those neighborhood pixels whose intensity are similar or close to that of the pixel of interest. The range kernel operates by acting on the pixel intensities. This makes the averaging process non-linear and computationally intensive, especially when the spatial filter is large. In this paper, we show how the O(1) averaging algorithms can be leveraged for realizing the bilateral filter in constant-time, by using trigonometric range kernels. This is done by generalizing the idea in [bilateralFilter_fast] of using polynomial range kernels. The class of trigonomet...

  15. Membrane solubilization in erythrocytes as a measure of radiation exposure to fast neutrons

    Science.gov (United States)

    Soltan Monem, A.; Ali, Fadel M.; Al-thani, Noura J. J.; Ali, Samira A.

    1999-02-01

    Membrane solubilization and osmotic fragility of rat erythrocytes irradiated in vivo with fast neutron fluences ranging from to using a source were measured instantaneously using a light scattering technique. The solubilization of erythrocyte membrane by a non-ionic detergent, octylglucoside (OG), was found to exhibit a two stage transition from vesicular form to mixed micellar form in the range of detergent concentrations 1.5-7.8 mM. The coexistence phase, vesicular/mixed micellar, was shifted towards higher detergent concentrations with increase in the neutron fluence, indicating increasing membrane resistance to the detergent and hence change in the natural membrane permeation properties. The technique shows an adequate sensitivity in detecting membrane damage in erythrocytes and has potential as a biophysical marker of radiation exposure. The osmotic fragility of irradiated erythrocytes shows a decreasing trend with increasing irradiation fluence measured directly and two weeks post-irradiation. Blood films photographed two weeks post-irradiation show developed elliptocytosis and crenated cell anaemia.

  16. Pulse-shape discrimination of the new plastic scintillators in neutron-gamma mixed field using fast digitizer card

    Science.gov (United States)

    Jančář, A.; Kopecký, Z.; Dressler, J.; Veškrna, M.; Matěj, Z.; Granja, C.; Solar, M.

    2015-11-01

    Recently invented plastic scintillator EJ-299-33 enables pulse-shape discrimination (PSD) and thus measurement of neutron and photon spectra in mixed fields. In this work we compare the PSD properties of EJ-299-33 plastic and the well-known NE-213 liquid scintillator in monoenergetic neutron fields generated by the Van de Graaff accelerator using the 3H(d, n)4He reaction. Pulses from the scintillators are processed by a newly developed digital measuring system employing the fast digitizer card. This card contains two AD converters connected to the measuring computer via 10 Gbps optical ethernet. The converters operate with a resolution of 12 bits and have two differential inputs with a sampling frequency 1 GHz. The resulting digital channels with different gains are merged into one composite channel with a higher digital resolution in a wide dynamic range of energies. Neutron signals are fully discriminated from gamma signals. Results are presented.

  17. Statistical estimation of the performance of a fast-neutron multiplicity system for nuclear material accountancy

    Energy Technology Data Exchange (ETDEWEB)

    Chichester, David L., E-mail: david.chichester@inl.gov [Idaho National Laboratory, 2525 N. Fremont Avenue, Idaho Falls, ID 83415 (United States); Thompson, Scott J.; Kinlaw, Mathew T.; Johnson, James T. [Idaho National Laboratory, 2525 N. Fremont Avenue, Idaho Falls, ID 83415 (United States); Dolan, Jennifer L.; Flaska, Marek; Pozzi, Sara A. [Department of Nuclear Engineering & Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, Ann Arbor, MI 48109-2104 (United States)

    2015-06-01

    Statistical analyses have been performed to develop bounding estimates of the expected performance of a conceptual fast-neutron multiplicity system (FNMS) for assaying plutonium. The conceptual FNMS design includes 32 cubic liquid scintillator detectors, measuring 7.62 cm per side, configured into 4 stacked rings of 8 detectors each. Expected response characteristics for the individual FNMS detectors, as well as the response characteristics of the entire FNMS, were determined using Monte Carlo simulations based on prior validation experiments. The results from these simulations were then used to estimate the Pu assay capabilities of the FNMS in terms of counting time, assay mass, and assay mass variance, using assay mass variance as a figure of merit. The analysis results are compared against a commonly used thermal-neutron coincidence counter. The advantages of using a fast-neutron counting system versus a thermal-neutron counting system are significant. Most notably, the time required to perform an assay to an equivalent assay mass variance is greatly reduced with a fast-neutron system, by more than an order of magnitude compared with that of the thermal-neutron system, due to the reduced probability of random summing with the fast system. The improved FNMS performance is especially relevant for assays involving Pu masses of 10 g or more.

  18. Low-Afterglow, High-Refractive-Index Liquid Scintillators for Fast-Neutron Spectrometry and Imaging Applications

    CERN Document Server

    Lauck, Ronald; Bromberger, Benjamin; Dangendorf, Volker; Goldberg, Mark B; Mor, Ilan; Tittelmeier, Kai; Vartsky, David

    2009-01-01

    For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents, that were enriched alternatively with nitrogen or oxygen. Dissolved molecular oxygen is known to be a highly effective quenching agent, that efficiently suppresses the population of the triplet states in the fluor, which are primarily responsible for the afterglow. For measuring the glow curves of scintillators, we have employed the time-correlated single photon counting (TCSPC) technique, characterized by high dynamic range of several orders of magnitude in light intensity. In this paper we outline the application for the fast scintillators, briefly present the scintillation mechanism in liquids, describe our specif...

  19. MEANDER-LINE CURRENT STRUCTURE DEVELOPMENT FOR SPALLATION NEUTRON SOURCE FAST CHOPPER

    Energy Technology Data Exchange (ETDEWEB)

    S. KURRENOY; J. POWER

    2000-10-01

    A new current structure for the fast traveling-wave 2.5-MeV beam chopper in the front end of the Spallation Neutron Source (SNS) has been suggested in [1]. The structure is based on the meander-folded notched stripline with dielectric supports and separators. Its design has been optimized using electromagnetic 3-D modeling with the MAFIA code package to provide rise and fall times in the range of 1 to 2 ns. A full-length (50 cm) prototype has been manufactured, and its preliminary measurements showed a good agreement with the calculations. Detailed measurements results and their comparison with simulations are presented. The latest front-end design requires a shorter, 35-cm chopper with a higher pulse voltage. Its meander-line current structure, based on the same principles, has also been optimized with MAFIA.

  20. Texas Instruments TPS7H1101-SP Fast Neutron Irradiation Results

    CERN Document Server

    The ATLAS collaboration

    2015-01-01

    Texas Instruments’s TPS7H1101-SP is an ultra low drop-out voltage regulator that operates under a wide range of input voltages - 1.5 to 7V. It can operate under a load of at most 3A and is radiation qualified by Texas Instruments for Total Ionizing Dose (TID) effects and Single Event Effects (SEE). For the application of the TPS7H1101-SP on the Front End Boards (FEBs) of the New Small Wheel (NSW) of the ATLAS detector, we study its susceptibility to a third kind of radiation effect -displacement damage- and present its performance in fast neutrons up to a dose of 6 x 10$^{14}$ 1MeVNE/cm$^{2}$.

  1. Measurement and calculations of long-lived radionuclide activity forming in the fast neutron field in some ITER construction steels

    Energy Technology Data Exchange (ETDEWEB)

    Pohorecki, W., E-mail: poho@agh.edu.pl [AGH University of Science and Technology, Faculty of Energy and Fuels, Al. Mickiewicza 30, 30-059 Krakow (Poland); Jodłowski, P. [AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. Mickiewicza 30, 30-059 Krakow (Poland); Pytel, K.; Prokopowicz, R. [National Centre for Nuclear Research, ul. Sołtana 7, 05-400 Otwock-Świerk (Poland)

    2014-10-15

    Highlights: • Measurement and calculations of long-lived gamma-emitting radionuclide activity forming in the fission reactor fast neutron field were done, in some ITER construction steels. • The neutron flux density was measured by means of activation foil method and unfolding technique. • Activity calculations were done by means of FISPACT-II code using the activation libraries EAF-2010 and TALYS-2011. • The activity measurements were done by means of gamma-ray spectrometry. - Abstract: Measurement and calculations of long-lived gamma-emitting radionuclide activity forming in the fission reactor fast neutron field were done, for some ITER construction steels. The activation was conducted in fast neutron irradiation channel of the MARIA research fission reactor (Poland). The dimensions of steel samples were 10 mm × 10 mm × 1 mm and mass was approximately 0.8 g. The neutron flux density was measured by means of activation foil method and unfolding technique; fraction of neutrons above 1 keV was 95%. The activation lasted 242 h and cooling took 100 days; the mean neutron flux density was 2.9E12 n/(cm{sup 2} s) (neutrons above 500 keV are 53% of total) whereas total fluency 2.53E18 cm{sup −2}. The activity measurements were done by means of gamma-ray spectrometry. Activity calculations were done by means of FISPACT-II code using the activation libraries EAF-2010 and TENDL-2011 and experimentally determined neutron flux. Measured activity of long-lived gamma emitting radionuclides was, in average, about 6.3 MBq/g 100 days after activation; the dominant radionuclides were {sup 58}Co and {sup 54}Mn (about 81% and 14% of total activity respectively). The C/E ratio differs for particular radionuclides and is in the range 0.86–0.92 for {sup 51}Cr, 0.93–1.21 for {sup 54}Mn, 0.77–0.98 for {sup 57}Co, 0.91–1.21 for {sup 58}Co, 1.17–1.27 for {sup 59}Fe, and 1.75–2.44 for {sup 60}Co.

  2. SWAN - Detection of explosives by means of fast neutron activation analysis

    Science.gov (United States)

    Gierlik, M.; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.

    2016-10-01

    In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project "Accelerators & Detectors" (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.

  3. Radiation Detection and Classification of Heavy Oxide Inorganic Scintillator Crystals for Detection of Fast Neutrons

    Science.gov (United States)

    2016-06-01

    and alkali-halide scintillators for potential use in neutron and gamma detection systems .” M.S. thesis, Dept. Physics , Naval Posgraduate School...DETECTION AND CLASSIFICATION OF HEAVY OXIDE INORGANIC SCINTILLATOR CRYSTALS FOR DETECTION OF FAST NEUTRONS by Jacob W. Capps June 2016 Thesis...DATE June 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE RADIATION DETECTION AND CLASSIFICATION OF HEAVY OXIDE

  4. Quasielastic neutron scattering measurements of fast process and methyl group dynamics in glassy poly(vinyl acetate)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Chuhong [Department of Chemistry, School of Engineering and Physical Sciences, Heriot-Watt University, Midlothian, Scotland, Edinburgh, EH14 4AS (United Kingdom); Arrighi, Valeria [Department of Chemistry, School of Engineering and Physical Sciences, Heriot-Watt University, Midlothian, Scotland, Edinburgh, EH14 4AS (United Kingdom)], E-mail: v.arrighi@hw.ac.uk; Gagliardi, Simona [Department of Chemistry, School of Engineering and Physical Sciences, Heriot-Watt University, Midlothian, Scotland, Edinburgh, EH14 4AS (United Kingdom); McEwen, Iain J. [Department of Chemistry, School of Engineering and Physical Sciences, Heriot-Watt University, Midlothian, Scotland, Edinburgh, EH14 4AS (United Kingdom); Tanchawanich, Jeerachada [Department of Chemistry, School of Engineering and Physical Sciences, Heriot-Watt University, Midlothian, Scotland, Edinburgh, EH14 4AS (United Kingdom); Telling, Mark T.F. [ISIS, Rutherford Appleton Laboratory, Chilton, Didcot, OX11 OQX (United Kingdom); Zanotti, J.-M. [Laboratoire Leon Brillouin (CEA-CNRS), CEA Saclay, 91191Gif-sur-Yvette Cedex (France)

    2006-09-29

    The dynamics of poly(vinyl acetate) (PVAc) in the glassy state has been investigated using a range of neutron spectrometers, sampling complementary energy and momentum transfer ranges. By combining the analysis of elastic window scan data at high resolution, medium resolution quasielastic neutron scattering (QENS) spectra and low resolution time-of-flight measurements we identify the molecular processes occurring in PVAc, below the polymer glass transition. Our QENS results are in agreement with the literature data for the methyl group rotation but we also find evidence for a fast process, with activation energy of 1.9 kJ/mol. Although the different instruments provide only limited dynamic information, we attempt to give a homogeneous description of molecular motion across the different energies and Q ranges.

  5. Measurement of accelerator neutron radiation field spectrum by Extended Range Neutron Multisphere Spectrometers and unfolding program

    CERN Document Server

    Li, Guanjia; Ma, Zhongjian; Guo, Siming; Yan, Mingyang; Shi, Haoyu; Xu, Chao

    2015-01-01

    This paper described a measurement of accelerator neutron radiation field at a transport beam line of Beijing-TBF. The experiment place was be selected around a Faraday Cup with a graphite target impacted by electron beam at 2.5GeV. First of all, we simulated the neutron radiation experiment by FLUKA. Secondly, we chose six appropriate ERNMS according to their neutron fluence response function to measure the neutron count rate. Then the U_M_G package program was be utilized to unfolding experiment data. Finally, we drew a comparison between the unfolding with the simulation spectrum and made an analysis about the result.

  6. Measured Thermal and Fast Neutron Fluence Rates for ATF-1 Holders During ATR Cycle 157D

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 157D which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution.

  7. Coded moderator approach for fast neutron source detection and localization at standoff

    Science.gov (United States)

    Littell, Jennifer; Lukosi, Eric; Hayward, Jason; Milburn, Robert; Rowan, Allen

    2015-06-01

    Considering the need for directional sensing at standoff for some security applications and scenarios where a neutron source may be shielded by high Z material that nearly eliminates the source gamma flux, this work focuses on investigating the feasibility of using thermal neutron sensitive boron straw detectors for fast neutron source detection and localization. We utilized MCNPX simulations to demonstrate that, through surrounding the boron straw detectors by a HDPE coded moderator, a source-detector orientation-specific response enables potential 1D source localization in a high neutron detection efficiency design. An initial test algorithm has been developed in order to confirm the viability of this detector system's localization capabilities which resulted in identification of a 1 MeV neutron source with a strength equivalent to 8 kg WGPu at 50 m standoff within ±11°.

  8. Fast response neutron emission monitor for fusion reactor using stilbene scintillator and Flash-ADC.

    Science.gov (United States)

    Itoga, T; Ishikawa, M; Baba, M; Okuji, T; Oishi, T; Nakhostin, M; Nishitani, T

    2007-01-01

    The stilbene neutron detector which has been used for neutron emission profile monitoring in JT-60U has been improved, to respond to the requirement to observe the high-frequency phenomena in megahertz region such as toroidicity-induced Alfvén Eigen mode in burning plasma as well as the spatial profile and the energy spectrum. This high-frequency phenomenon is of great interest and one of the key issues in plasma physics in recent years. To achieve a fast response in the stilbene detector, a Flash-ADC is applied and the wave form of the anode signal stored directly, and neutron/gamma discrimination was carried out via software with a new scheme for data acquisition mode to extend the count rate limit to MHz region from 1.3 x 10(5) neutron/s in the past, and confirmed the adequacy of the method.

  9. A high-field adiabatic fast passage ultracold neutron spin flipper for the UCNA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Holley, A. T.; Pattie, R. W.; Young, A. R. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Broussard, L. J. [Department of Physics, Duke University, Durham, North Carolina 27708 (United States); Davis, J. L.; Ito, T. M.; Lyles, J. T. M.; Makela, M.; Morris, C. L.; Mortensen, R.; Saunders, A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Hickerson, K.; Mendenhall, M. P. [W. K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Liu, C.-Y. [Department of Physics, Indiana University, Bloomington, Indiana 47405 (United States); Mammei, R. R. [Department of Physics, Virginia Tech, Blacksburg, Virginia 24061 (United States); Rios, R. [Department of Physics, Idaho State University, Pocatello, Idaho 83209 (United States)

    2012-07-15

    The UCNA collaboration is making a precision measurement of the {beta} asymmetry (A) in free neutron decay using polarized ultracold neutrons (UCN). A critical component of this experiment is an adiabatic fast passage neutron spin flipper capable of efficient operation in ambient magnetic fields on the order of 1 T. The requirement that it operate in a high field necessitated the construction of a free neutron spin flipper based, for the first time, on a birdcage resonator. The design, construction, and initial testing of this spin flipper prior to its use in the first measurement of A with UCN during the 2007 run cycle of the Los Alamos Neutron Science Center's 800 MeV proton accelerator is detailed. These studies determined the flipping efficiency of the device, averaged over the UCN spectrum present at the location of the spin flipper, to be {epsilon}=0.9985(4).

  10. Fast neutron flux analyzer with real-time digital pulse shape discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Ivanova, A.A., E-mail: a.a.ivanova@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Zubarev, P.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Ivanenko, S.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Khilchenko, A.D. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Kotelnikov, A.I. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Polosatkin, S.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Novosibirsk State University, 630090 Novosibirsk (Russian Federation); Puryga, E.A.; Shvyrev, V.G. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Sulyaev, Yu.S. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, 630090 Novosibirsk (Russian Federation)

    2016-08-11

    Investigation of subthermonuclear plasma confinement and heating in magnetic fusion devices such as GOL–3 and GDT at the Budker Institute (Novosibirsk, Russia) requires sophisticated equipment for neutron-, gamma- diagnostics and upgrading data acquisition systems with online data processing. Measurement of fast neutron flux with stilbene scintillation detectors raised the problem of discrimination of the neutrons (n) from background cosmic particles (muons) and neutron-induced gamma rays (γ). This paper describes a fast neutron flux analyzer with real-time digital pulse-shape discrimination (DPSD) algorithm FPGA-implemented for the GOL–3 and GDT devices. This analyzer was tested and calibrated with the help of {sup 137}Cs and {sup 252}Cf radiation sources. The Figures of Merit (FOM) calculated for different energy cuts are presented. - Highlights: • Electronic equipment for measurement of fast neutron flux with stilbene scintillator is presented. • FPGA-implemented digital pulse-shape discrimination algorithm by charge comparison method is shown. • Calibration of analyzer was carried out with {sup 137}Cs and {sup 252}Cf. • Figures of Merit (FOM) values for energy cuts from 1/8 Cs to 2 Cs are from 1.264 to 2.34 respectively.

  11. Mosaic diamond detectors for fast neutrons and large ionizing radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Girolami, Marco; Calvani, Paolo; Trucchi, Daniele M. [Istituto di Struttura della Materia (ISM), Consiglio Nazionale delle Ricerche (CNR), Rome (Italy); Bellucci, Alessandro [Istituto di Struttura della Materia (ISM), Consiglio Nazionale delle Ricerche (CNR), Rome (Italy); Dipartimento di Fisica, Universita degli Studi di Roma ' ' La Sapienza' ' , Rome (Italy); Cazzaniga, Carlo; Rebai, Marica; Rigamonti, Davide [Dipartimento di Fisica, Universita degli Studi di Milano-Bicocca, Milano (Italy); Istituto di Fisica dei Plasmi (IFP), Consiglio Nazionale delle Ricerche (CNR), Milano (Italy); Tardocchi, Marco [Istituto di Fisica dei Plasmi (IFP), Consiglio Nazionale delle Ricerche (CNR), Milano (Italy); Pillon, Mario [ENEA, Centro Ricerche di Frascati, Rome (Italy)

    2015-11-15

    First neutron and X-ray beam tests on a novel 12-pixel single-crystal diamond mosaic detector are presented and discussed. Preliminary characterization of single-pixel electronic properties, performed with α particles, results in charge carrier mobilities >2000 cm{sup 2} Vs{sup -1} and saturation velocities of the order of 10{sup 7} cm s{sup -1}. Signal stability over time, measured with a {sup 241}Am source (37 kBq activity), is longer than 5 h. Tests under an intense X-ray beam (1 Gy h{sup -1} dose-rate) show a very good response uniformity (down to about 1% of relative standard deviation from mean value), suggesting a high level of pixel reproducibility at intermediate bias voltages (ranging from 20 to 100 V). Response uniformity reduces at voltages >200 V, due presumably to radiation-assisted detrapping effects. Preliminary results of 12-pixel simultaneous acquisitions of X-ray beam profiles and pulse height spectra under a fast neutron beam (14 MeV) are also presented. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Design and expected performance of a fast neutron attenuation probe for light element density measurements

    Science.gov (United States)

    Sweany, M.; Marleau, P.

    2016-10-01

    We present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20-30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Finally, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5-10% level for a two hour scan time.

  13. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    Energy Technology Data Exchange (ETDEWEB)

    Thorngate, J.H.

    1988-11-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs.

  14. Use of CR 39 Films for Evaluation of Shielding Efficacy of Materials against Fast Neutrons

    OpenAIRE

    1992-01-01

    CR-39 films have been used for evaluation of neutron shielding of metal alloys, different types of rubbers, sand polymers, etc. These films have been chosen because of their ability to record fast neutrons from 200 keV-10 MeV and their insensitivity to gamma radiations. Tenth value layer (TVL) for the materials studied varies from 10.5 to 28.6 cm. In addition, the values of TVL have also been computed for standard material, such as Al, steel, etc. Using neutron removal cross-section da...

  15. Transmission of fast neutrons along cylindrical air-filled ducts pierced in ilmenite concrete

    Energy Technology Data Exchange (ETDEWEB)

    Megahid, R.M.; Bashter, I.I.

    1980-01-01

    The variation of flux of fast neutrons along air filled ducts passing through ilmenite concrete of density 4.6 gm. cm/sup -3/ was measured. Ducts of diameter 2.9, 5.8 and 10 cm were used. Measurements were carried out at different distances (up to 120 cm) along the duct axis. The source of neutrons was a collimated beam of reactor neutrons emitted from one of the horizontal channels of ET-RR-1 reactor. All measurements were performed using phosphorus activation detectors. The data obtained show the dependence of flux values on duct length and diameter.

  16. Coupled neutronics and thermal-hydraulics numerical simulations of a Molten Fast Salt Reactor (MFSR)

    Science.gov (United States)

    Laureau, A.; Rubiolo, P. R.; Heuer, D.; Merle-Lucotte, E.; Brovchenko, M.

    2014-06-01

    Coupled neutronics and thermalhydraulic numerical analyses of a molten salt fast reactor are presented. These preliminary numerical simulations are carried-out using the Monte Carlo code MCNP and the Computation Fluid Dynamic code OpenFOAM. The main objectives of this analysis performed at steady-reactor conditions are to confirm the acceptability of the current neutronic and thermalhydraulic designs of the reactor, to study the effects of the reactor operating conditions on some of the key MSFR design parameters such as the temperature peaking factor. The effects of the precursor's motion on the reactor safety parameters such as the effective fraction of delayed neutrons have been evaluated.

  17. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    CERN Document Server

    Al-Jarallah, M I; Fazal-Ur-Rehman; Abu-Jarad, F A

    2002-01-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has bee...

  18. Microdosimetric investigations at the Fast Neutron Therapy Facility at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Langen, K.M.

    1997-12-31

    Microdosimetry was used to investigate three issues at the neutron therapy facility (NTF) at Fermilab. Firstly, the conversion factor from absorbed dose in A-150 tissue equivalent plastic to absorbed dose in ICRU tissue was determined. For this, the effective neutron kerma factor ratios, i.e. oxygen tissue equivalent plastic and carbon to A-150 tissue equivalent plastic, were measured in the neutron beam. An A-150 tissue equivalent plastic to ICRU tissue absorbed dose conversion factor of 0.92 {+-} 0.04 determined. Secondly, variations in the radiobiological effectiveness (RBE) in the beam were mapped by determining variations in two related quantities, e{sup *} and R, with field size and depth in tissue. Maximal variation in e{sup *} and R of 9% and 15% respectively were determined. Lastly, the feasibility of utilizing the boron neutron capture reaction on boron-10 to selectively enhance the tumor dose in the NTF beam was investigated. In the unmodified beam, a negligible enhancement for a 50 ppm boron loading was measured. To boost the boron dose enhancement to 3% it was necessary to change the primary proton energy from 66 MeV and to filter the beam by 90 mm of tungsten.

  19. Studies with the fast neutron generator at Andhra University, Waltair

    Energy Technology Data Exchange (ETDEWEB)

    Lakshmana Das, N.; Srinivasa Rao, C.V.; Sudhakara Reddy, D.; Viswes Wara Rao, V.; Khsirasagar, T.V.S.R.; Thirumala Rao, B.V.; Rama Rao, J.; Lakshminarayana, V.

    1977-01-01

    Installation and operation of the 600 keV proton and deuteron accelerator are discussed. Performance of the accelerator as a neutron generator is given and three lines of experimentation are discussed. These are: production of short-lived isotopes for nuclear spectroscopy; differential estimation of carbon, oxygen and nitrogen; and estimation of relative amounts of thorium in the beach sands of Visakhapatnam. (GHT)

  20. Aspects of the physics and chemistry of water radiolysis by fast neutrons and fast electrons in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    McCracken, D.R. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Tsang, K.T. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Laughton, P.J

    1998-09-01

    Detailed radiation physics calculations of energy deposition have been done for the coolant of CANDU reactors and Pressurized Water Reactors (PWRs). The geometry of the CANDU fuel channel was modelled in detail. Fluxes and energy-deposition rates for neutrons, recoil ions, photons, and fast electrons have been calculated using MCNP4B, WIMS-AECL, and specifically derived energy-transfer factors. These factors generate the energy/flux spectra of recoil ions from fast-neutron energy/flux spectra. The energy spectrum was divided into 89 discrete ranges (energy bins).The production of oxidizing species and net coolant radiolysis can be suppressed by the addition of hydrogen to the coolant of nuclear reactors. It is argued that the net dissociation of coolant by gamma rays is suppressed by lower levels of excess hydrogen than when dissociation is by ion recoils. This has consequences for the modelling of coolant radiolysis by homogeneous kinetics. More added hydrogen is required to stop water radiolysis by recoil ions acting alone than if recoil ions and gamma rays acted concurrently in space and time. Homogeneous kinetic models and experimental data suggest that track overlap is very inefficient in providing radicals from gamma-ray tracks to recombine molecular products in ion-recoil tracks. An inhomogeneous chemical model is needed that incorporates ionizing-particle track structure and track overlap. Such a model does not yet exist, but a number of limiting cases using homogeneous kinetics are discussed. There are sufficient uncertainties and contradictions in the data relevant to the radiolysis of reactor coolant that the relatively high CHC's (critical hydrogen concentration) observed in NRU reactor experiments (compared to model predictions) may be explainable by errors in fundamental data and understanding of water radiolysis under reactor conditions. The radiation chemistry program at CRL has been focused to generate quantitative water-radiolysis data in a

  1. An Electromagnet for Precession of the Polarization of Fast-Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Aspesund, O.; Bjorkman, J.; Trumpy, G.

    1965-05-15

    The advantages of using a transverse magnetic field for precessing the polarization of fast-neutrons are discussed. Design details of a powerful electromagnet supplying a transverse field of approximately 20 kGauss are given. Precession characteristics for polarized fast neutrons obtained at 50 deg (lab. syst.) from the Li{sup 7} (p, n) Be{sup 7} reaction are reported, using elastic scattering at 42 deg (lab. syst.) off natural carbon as an analyser. Correlation of the precession data with theoretical predictions presented elsewhere is made, and good agreement is found.

  2. Feasibility study for measurement of insulation compaction in the cryogenic rocket fuel storage tanks at Kennedy Space Center by fast/thermal neutron techniques

    Science.gov (United States)

    Livingston, R. A.; Schweitzer, J. S.; Parsons, A. M.; Arens, E. E.

    2014-02-01

    The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Some of the perlite may have compacted over time, compromising the thermal performance and also the structural integrity of the tanks. Neutrons can readily penetrate through the 1.75 cm outer steel shell and through the entire 120 cm thick perlite zone. Neutrons interactions with materials produce characteristic gamma rays which are then detected. In compacted perlite the count rates in the individual peaks in the gamma ray spectrum will increase. Portable neutron generators can produce neutron simultaneous fluxes in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scattering which is sensitive to Si, Al, Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA), which is sensitive to Si, Al, Na, K and H among others. The results of computer simulations using the software MCNP and measurements on a test article suggest that the most promising approach would be to operate the system in time-of-flight mode by pulsing the neutron generator and observing the subsequent die away curve in the PGNA signal.

  3. Feasibility study for measurement of insulation compaction in the cryogenic rocket fuel storage tanks at Kennedy Space Center by fast/thermal neutron techniques

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, R. A. [Materials Science and Engineering Dept., U. of Maryland, College Park, MD (United States); Schweitzer, J. S. [Physics Dept., U. of Connecticut, Storrs (United States); Parsons, A. M. [Goddard Space Flight Center, Greenbelt (United States); Arens, E. E. [John F. Kennedy Space Center, FL (United States)

    2014-02-18

    The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Some of the perlite may have compacted over time, compromising the thermal performance and also the structural integrity of the tanks. Neutrons can readily penetrate through the 1.75 cm outer steel shell and through the entire 120 cm thick perlite zone. Neutrons interactions with materials produce characteristic gamma rays which are then detected. In compacted perlite the count rates in the individual peaks in the gamma ray spectrum will increase. Portable neutron generators can produce neutron simultaneous fluxes in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scattering which is sensitive to Si, Al, Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA), which is sensitive to Si, Al, Na, K and H among others. The results of computer simulations using the software MCNP and measurements on a test article suggest that the most promising approach would be to operate the system in time-of-flight mode by pulsing the neutron generator and observing the subsequent die away curve in the PGNA signal.

  4. Measuring the Cosmic Ray Muon-Induced Fast Neutron Spectrum by (n,p) Isotope Production Reactions in Underground Detectors

    CERN Document Server

    Galbiati, C; Galbiati, Cristiano; Beacom, John. F.

    2005-01-01

    While cosmic ray muons themselves are relatively easy to veto in underground detectors, their interactions with nuclei create more insidious backgrounds via: (i) the decays of long-lived isotopes produced by muon-induced spallation reactions inside the detector, (ii) spallation reactions initiated by fast muon-induced neutrons entering from outside the detector, and (iii) nuclear recoils initiated by fast muon-induced neutrons entering from outside the detector. These backgrounds, which are difficult to veto or shield against, are very important for solar, reactor, dark matter, and other underground experiments, especially as increased sensitivity is pursued. We used fluka to calculate the production rates and spectra of all prominent secondaries produced by cosmic ray muons, in particular focusing on secondary neutrons, due to their importance. Since the neutron spectrum is steeply falling, the total neutron production rate is sensitive just to the relatively soft neutrons, and not to the fast-neutron compon...

  5. Measurement of Fission Product Yields from Fast-Neutron Fission

    Science.gov (United States)

    Arnold, C. W.; Bond, E. M.; Bredeweg, T. A.; Fowler, M. M.; Moody, W. A.; Rusev, G.; Vieira, D. J.; Wilhelmy, J. B.; Becker, J. A.; Henderson, R.; Kenneally, J.; Macri, R.; McNabb, D.; Ryan, C.; Sheets, S.; Stoyer, M. A.; Tonchev, A. P.; Bhatia, C.; Bhike, M.; Fallin, B.; Gooden, M. E.; Howell, C. R.; Kelley, J. H.; Tornow, W.

    2014-09-01

    One of the aims of the Stockpile Stewardship Program is a reduction of the uncertainties on fission data used for analyzing nuclear test data [1,2]. Fission products such as 147Nd are convenient for determining fission yields because of their relatively high yield per fission (about 2%) and long half-life (10.98 days). A scientific program for measuring fission product yields from 235U,238U and 239Pu targets as a function of bombarding neutron energy (0.1 to 15 MeV) is currently underway using monoenergetic neutron beams produced at the 10 MV Tandem Accelerator at TUNL. Dual-fission chambers are used to determine the rate of fission in targets during activation. Activated targets are counted in highly shielded HPGe detectors over a period of several weeks to identify decaying fission products. To date, data have been collected at neutron bombarding energies 4.6, 9.0, 14.5 and 14.8 MeV. Experimental methods and data reduction techniques are discussed, and some preliminary results are presented.

  6. Core Power Control of the fast nuclear reactors with estimation of the delayed neutron precursor density using Sliding Mode method

    Energy Technology Data Exchange (ETDEWEB)

    Ansarifar, G.R., E-mail: ghr.ansarifar@ast.ui.ac.ir; Nasrabadi, M.N.; Hassanvand, R.

    2016-01-15

    Highlights: • We present a S.M.C. system based on the S.M.O for control of a fast reactor power. • A S.M.O has been developed to estimate the density of delayed neutron precursor. • The stability analysis has been given by means Lyapunov approach. • The control system is guaranteed to be stable within a large range. • The comparison between S.M.C. and the conventional PID controller has been done. - Abstract: In this paper, a nonlinear controller using sliding mode method which is a robust nonlinear controller is designed to control a fast nuclear reactor. The reactor core is simulated based on the point kinetics equations and one delayed neutron group. Considering the limitations of the delayed neutron precursor density measurement, a sliding mode observer is designed to estimate it and finally a sliding mode control based on the sliding mode observer is presented. The stability analysis is given by means Lyapunov approach, thus the control system is guaranteed to be stable within a large range. Sliding Mode Control (SMC) is one of the robust and nonlinear methods which have several advantages such as robustness against matched external disturbances and parameter uncertainties. The employed method is easy to implement in practical applications and moreover, the sliding mode control exhibits the desired dynamic properties during the entire output-tracking process independent of perturbations. Simulation results are presented to demonstrate the effectiveness of the proposed controller in terms of performance, robustness and stability.

  7. A Fast Pulsed Neutron Source for Time-of-Flight Detection of Nuclear Materials and Explosives

    Science.gov (United States)

    Krishnan, Mahadevan; Bures, Brian; James, Colt; Madden, Robert; Hennig, Wolfgang; Breus, Dimitry; Asztalos, Stephen; Sabourov, Konstantin; Lane, Stephen

    2011-12-01

    AASC has built a fast pulsed neutron source based on the Dense Plasma Focus (DPF). The more current version stores only 100 J but fires at ˜10-50 Hz and emits ˜106n/pulse at a peak current of 100 kA. Both sources emit 2.45±0.1 MeV (DD) neutron pulses of ˜25-40 ns width. Such fast, quasi-monoenergetic pulses allow time-of-flight detection of characteristic emissions from nuclear materials or high explosives. A test is described in which iron targets were placed at different distances from the point neutron source. Detectors such as Stilbene and LaBr3 were used to capture inelastically induced, 847 keV gammas from the iron target. Shielding of the source and detectors eliminated most (but not all) of the source neutrons from the detectors. Gated detection, pulse shape analysis and time-of-flight discrimination enable separation of gamma and neutron signatures and localization of the target. A Monte Carlo simulation allows evaluation of the potential of such a fast pulsed source for a field-portable detection system. The high rep-rate source occupies two 200 liter drums and uses a cooled DPF Head that is <500 cm3 in volume.

  8. A Fast Pulsed Neutron Source for Time-of-Flight Detection of Nuclear Materials and Explosives

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, Mahadevan; Bures, Brian; James, Colt; Madden, Robert [Alameda Applied Sciences Corporation, 3077 Teagarden Street, San Leandro, CA 94577 (United States); Hennig, Wolfgang; Breus, Dimitry; Asztalos, Stephen; Sabourov, Konstantin [XIA LLC, 31057 Genstar Road, Hayward, CA 94544 (United States); Lane, Stephen [NSF Center for Biophotonics and School of Medicine, University of California Davis, Sacramento CA, 95817 (United States)

    2011-12-13

    AASC has built a fast pulsed neutron source based on the Dense Plasma Focus (DPF). The more current version stores only 100 J but fires at {approx}10-50 Hz and emits {approx}10{sup 6}n/pulse at a peak current of 100 kA. Both sources emit 2.45{+-}0.1 MeV(DD) neutron pulses of {approx}25-40 ns width. Such fast, quasi-monoenergetic pulses allow time-of-flight detection of characteristic emissions from nuclear materials or high explosives. A test is described in which iron targets were placed at different distances from the point neutron source. Detectors such as Stilbene and LaBr3 were used to capture inelastically induced, 847 keV gammas from the iron target. Shielding of the source and detectors eliminated most (but not all) of the source neutrons from the detectors. Gated detection, pulse shape analysis and time-of-flight discrimination enable separation of gamma and neutron signatures and localization of the target. A Monte Carlo simulation allows evaluation of the potential of such a fast pulsed source for a field-portable detection system. The high rep-rate source occupies two 200 liter drums and uses a cooled DPF Head that is <500 cm{sup 3} in volume.

  9. Determination of the fast neutrons spectra by the Elastic scattering method (n, p)

    CERN Document Server

    Elizalde, J

    1973-01-01

    This work consists in determining the fast neutron spectra emitted by a Pu-Be isotopic source. The implemented technique is based in the spectrometry (n, p). This consists in making to fall on a fast neutrons beams (polyenergetic) over a thin film of hydrogenated material, detecting the spectra of emitted protons at a fix angle. The polyethylene film and the used solid state detector are inside of a vacuum chamber. The detector is placed at 30 degree with respect to direction of the incident neutrons beam. The protons spectra is stored in a multichannel. the energy is obtained with the prior calibration of the system. The data processing involves the transformation of the protons spectra observed at the falling on neutrons spectra over the film. The energy of the neutrons is related with that of the protons, according to the collision kinematical equations. The cross section of elastic collision of the neutrons with the hydrogen atoms is obtained from literature. Applying these relations to the observed spect...

  10. Analysis of the scintillation mechanism in a pressurized 4He fast neutron detector using pulse shape fitting

    OpenAIRE

    R.P. Kelley; Murer, D.; Ray, H.; K.A. Jordan

    2015-01-01

    An empirical investigation of the scintillation mechanism in a pressurized 4He gas fast neutron detector was conducted using pulse shape fitting. Scintillation signals from neutron interactions were measured and averaged to produce a single generic neutron pulse shape from both a 252Cf spontaneous fission source and a (d,d) neutron generator. An expression for light output over time was then developed by treating the decay of helium excited states in the same manner as the decay of radioactiv...

  11. A charge-collection method for measurements of pulsed fast-neutron flux

    CERN Document Server

    Ouyang, X P; Ho, Y K; Zhang, Z B

    2002-01-01

    A charge-collection method for measuring the flux of pulsed fast neutrons in current mode has been developed, which is based on the well-known recoil-proton method combined with ion-induced secondary electron emission from solid surfaces. The detection unit consists of four elements: an n-p converter, an absorber, a collector, and a rear insulator. The assembly does not require vacuum for operation. Recoil protons from the n-p converter and the secondary electrons induced by the passing protons on the interface of the absorber and the collector contribute to the detector output signal. By properly choosing the materials and the combination of the absorber and the collector, the fraction of secondary electrons in the output signal can be determined experimentally. This detection concept allows one to design a medium type of fast-neutron detector for measurements of extremely intense pulsed neutron flux with a number of advantages over the existing systems.

  12. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  13. Monte Carlo simulations to advance characterisation of landmines by pulsed fast/thermal neutron analysis

    NARCIS (Netherlands)

    Maucec, M.; Rigollet, C.

    2004-01-01

    The performance of a detection system based on the pulsed fast/thermal neutron analysis technique was assessed using Monte Carlo simulations. The aim was to develop and implement simulation methods, to support and advance the data analysis techniques of the characteristic gamma-ray spectra, potentia

  14. Fast neutron radiation induced Glu-B1 deficient lines of an elite bread wheat variety

    Science.gov (United States)

    Five isogenic wheat lines deficient in high-molecular weight subunit (HMW-GS) proteins encoded by the B-genome were identified from a fast-neutron radiation-mutagenized population of Summit, an elite variety of bread wheat (Triticum aestivum L.). The mutant lines differ from the wild-type progenit...

  15. Calculation of dosimetry parameters for fast neutron radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wells, A.H.

    1978-05-01

    A computer simulation of the interactions of 50 MeV d/sup +/ on Be and 42 MeV p/sup +/ on Be neutron spectra with ICRU muscle tissue and Shonka A-150 tissue equivalent plastic was performed to allow computation of the charged particle spectra that result. Nuclear data were obtained from the Evaluated Nuclear Data File (ENDF) whenever possible and from the Intranuclear Cascade and Evaporation models otherwise. The dosimetry parameters calculated are: the kerma ratio, K/sub A-150//K/sub tissue/; the energy required to form an ion pair, W; and the stopping power ratio, S/sub g//sup W/.

  16. Study of neutron irradiated silicon counters with a fast amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Bates, S.; Munday, D.J.; Parker, M.A.; Anghinolfi, F.; Chilingarov, A.; Ciasnohova, A.; Glaser, M.; Jarron, P.; Lemeilleur, F.; Santiard, J.C.; Goessling, C.; Lisowski, B.; Pilath, S.; Rolf, A.; Bonino, R.; Clark, A.G.; Kambara, H.; Wu, X.; Fretwurst, E.; Lindstroem, G.; Schulz, T.; Moorhead, G.F.; Taylor, G.N.; Tovey, S.N.; Hawkings, R.; Weidberg, A.; Teiger, J. (Cavendish Lab., Univ. of Cambridge (United Kingdom) CERN, Geneva (Switzerland) Inst. fuer Physik, Univ. Dortmund (Germany) DPNC, Geneva Univ. (Switzerland) 1. Inst. fuer Experimentalphysik, Univ. Hamburg (Germany) School of Physics, Univ. of Melbourne, Parkville, Victoria (Australia) Dept. of Nuclear Physics, Oxford Univ. (United Kingdom) Centre d' Etudes Nucleaires de Saclay, 91 Gif-sur-Yvette (France)); RD2 Collaboration

    1993-12-15

    Silicon detectors have been irradiated with fluences of up to 2.7x10[sup 13] neutrons/cm[sup 2], and have been subsequently studied using low-noise preamplifiers with a peaking time of about 15 ns. The detector response to minimum ionizing particles was found to be close to that of non-irradiated detectors. The short integration time of the preamplifier makes the shot noise due to the detector dark current tolerable up to at least 15 [mu]A/channel. (orig.)

  17. Energy-dispersive study of the interactions of fast neutrons with matter

    CERN Document Server

    Altstadt, E; Eckert, S; Freiesleben, H; Galindo, V; Grosse, E; Naumann, B; Weiss, F P

    2003-01-01

    The construction and the first use of a compact time-of-flight system for the energy-dispersive study of the interaction of fast neutrons with materials are content of a network project of the Research Center Rossendorf, to which also the Technical University Dresden contributes in the framework of a common DFG project. The planned time-of-flight experiments with pulsed neutrons will be performed at the radiation source ELBE. First results on the development of a neutron-production target are presented. By means of radiation-transport and finite-element programs the distributions of the energy deposition of the used pulsed electron beam of the radiation source ELBE and the temperature in the neutron radiator as well as the expected particle spectra and fluxes at the measurement place were calculated. Considerations on the development of a beam catcher are discussed.

  18. Theoretical study and calculation of the response of a fast neutron dosemeter based on track detection

    Energy Technology Data Exchange (ETDEWEB)

    Decossas, J.L.; Vareille, J.C.; Moliton, J.P.; Teyssier, J.L. (Limoges Univ., 87 (France). Lab. d' Electronique des Polymeres sous Faisceaux Ioniques)

    1983-01-01

    A fast neutron dosemeter is generally composed of a radiator in which n-p elastic scattering occurs and a detector which registers protons. A theoretical study, and the calculation (FORTRAN program) of the response of such a dosemeter is presented involving two steps: 1) The proton flux emerging from a thick radiator on which monoenergetic neutrons are normally incident is studied. This is characterised by its energy spectrum depending on the neutron energy and on the radiator thickness. 2) Proton detection being achieved with a solid state nuclear track detector whose performance is known, the number of registered tracks are calculated. The dosemeter sensitivity (tracks cm/sup -2/. Sv/sup -1/) is deduced. Then, the calculations show that it is possible to optimise the radiator thickness to obtain the smallest variation in sensitivity with neutron energy. The theoretical results are in good agreement with the experimental ones found in the literature.

  19. Measurements of effective delayed neutron fraction in a fast neutron reactor using the perturbation method

    Science.gov (United States)

    Zhou, Hao-Jun; Yin, Yan-Peng; Fan, Xiao-Qiang; Li, Zheng-Hong; Pu, Yi-Kang

    2016-06-01

    A perturbation method is proposed to obtain the effective delayed neutron fraction β eff of a cylindrical highly enriched uranium reactor. Based on reactivity measurements with and without a sample at a specified position using the positive period technique, the reactor reactivity perturbation Δρ of the sample in β eff units is measured. Simulations of the perturbation experiments are performed using the MCNP program. The PERT card is used to provide the difference dk of effective neutron multiplication factors with and without the sample inside the reactor. Based on the relationship between the effective multiplication factor and the reactivity, the equation β eff = dk/Δρ is derived. In this paper, the reactivity perturbations of 13 metal samples at the designable position of the reactor are measured and calculated. The average β eff value of the reactor is given as 0.00645, and the standard uncertainty is 3.0%. Additionally, the perturbation experiments for β eff can be used to evaluate the reliabilities of the delayed neutron parameters. This work shows that the delayed neutron data of 235U and 238U from G.R. Keepin’s publication are more reliable than those from ENDF-B6.0, ENDF-B7.0, JENDL3.3 and CENDL2.2. Supported by Foundation of Key Laboratory of Neutron Physics, China Academy of Engineering Physics (2012AA01, 2014AA01), National Natural Science Foundation (11375158, 91326104)

  20. Study of the propagation of fast neutrons in water, by Monte-Carlo methods; Etude de la propagation des neutrons rapides dans l'eau par des methodes de Monte-Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Lafore, P.; Lattes, R.; Millot, J.P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied the propagation in water of neutrons from mono-directional plane sources with energies ranging from 300 keV to 19,66 MeV, placed in an infinite water medium. The exact paths of a number of neutrons are determined, taking into account the microscopic sections, assuming that inelastic collisions of the neutrons on oxygen are absorptions, and neglecting the loss of energy by elastic collisions on oxygen. The neutron lifetimes have been made use of to study the propagation of neutrons from fission sources, Po-Be, Po-B and Ra-Be, as well as the reflection of fast neutrons on a semi-infinite water medium. We have taken complete account of the first collision in order to improve the precision of the results. The calculations were carried out by Mrs J. VASSEUR and Mr A. GUILLOU. (author)Fren. [French] Nous etudions la propagation dans l'eau des neutrons a partir de sources planes monodirectionnelles dont les energies sont repartis de 300 keV a 19,66 MeV, placees dans un milieu infini d'eau. Nous determinons les trajectoires exactes d'un certain nombre de neutrons en tenant compte des sections microscopiques, en supposant que les chocs inelastiques des neutrons sur l'oxygene sont des absorptions, et en negligeant la perte d'energie par chocs elastiques sur l'oxygene. Les vies de neutrons ont ete exploitees pour etudier la propagation des neutrons a partir de sources de fission, Po-Be, Po-B et Ra-Be, ainsi que la reflexion des neutrons rapides sur un milieu semi-infini d'eau. On a tenu compte integralement du premier choc pour ameliorer la precision des resultats. Les calculs ont ete effectues par Mme J. VASSEUR et M.A. GUILLOU. (auteur)

  1. The use of the neutronic calculation code CORNER for evaluating the protection of fast neutron reactor and CNFC equipment

    Science.gov (United States)

    Shekhanova, M. E.

    2017-01-01

    In this paper we propose a method of using neutronic calculation code CORNER to the analysis of experiments on the protection of fast neutron reactor and CNFC equipment. An example of Winfrith Graphite Benchmark experiment calculation using this approach is presented. This task can be considered as one step in the general theme of the safety analysis of FR with liquid metal coolant, their fuel cycles and related equipment. CORNER implement a solution of the kinetic equation with a source in the three-dimensional hexagonal geometry based on Sn-method. The purpose of this paper is a demonstration of the application of CORNER’s possibilities for the analysis of the actual reactor problems.

  2. Characterization of Heavy Oxide Inorganic Scintillator Crystals for Direct Detection of Fast Neutrons Based on Inelastic Scattering

    Science.gov (United States)

    2015-03-01

    emission of additional gamma photons that likewise cause scintillation [4]. The specific goals of this research are to:  explore the physics of fast ...reaction products are registered; also in the sense that, in the case of fast neutrons, moderation is normally required before the absorption event...various other forms of radiation, fast neutrons are the crux of the overall study, and every effort should be made to test with them. 39 LIST OF

  3. Nuclear Science with Thermal and Fast Neutrons at UMass Lowell

    Science.gov (United States)

    Guess, C. J.; Chowdhury, P.; Borges, N.; D'Olympia, N.; Deo, A. Y.; Harrington, T.; Hota, S.; Jackson, E. G.; Kegel, G.; Lakshmi, S.; Parker, G.; Prasher, V. S.; Recca, K.; Regan, T.; Thomas, J.; Yuan, Q.

    2011-10-01

    Increased interest in improving nuclear data for applied nuclear science has prompted new research activity at the UMass Lowell Radiation Laboratory. At the 5.5-MV CN Van de Graaff accelerator facility, the beamline for precision (n, γ) and (n,n' γ) measurements with sub-nanosecond proton beam bunches is being refurbished. A proton microbeam facility is being installed for interdisciplinary studies of materials using applied nuclear techniques. In addition, the thermal column of the 1-MW research reactor will be fitted with a new shielded area for thermal (n, γ) measurements. Neutron flux measurements, shielding calculations, and simulations are underway. Progress, status and research plans with these facilities will be discussed. This work is supported by the US Department of Energy.

  4. Nuclear Waste Removal Using Particle Beams Incineration with Fast Neutrons

    CERN Document Server

    Revol, Jean Pierre Charles

    1997-01-01

    The management of nuclear waste is one of the major obstacles to the acceptability of nuclear power as a main source of energy for the future. TARC, a new experiment at CERN, is testing the practicality of Carlo Rubbia's idea to make use of Adiabatic Resonance Crossing to transmute long-lived fission fragments into short-lived or stable nuclides. Spallation neutrons produced in a large Lead assembly have a high probability to be captured at the energies of cross-section resonances in elements such as 99Tc, 129I, etc. An accelerator-driven sub-critical device using Thorium (Energy Amplifier) would be very effective in eliminating TRansUranic elements which constitute the most dangerous part of nuclear waste while producing from it large amounts of energy. In addition, such a system could transform, at a high rate and little energetic cost, long-lived fission fragments into short-lived elements.

  5. System of Modelling and Calculation Analysis of Neutron- Physical Experiments at Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Moiseyev, A.V. [SSC RF - IPPE, 1 Bondarenko Square, Obninsk, Kaluga Region 249033 (Russian Federation)

    2008-07-01

    There is an actual task on storage, processing and analysis of the unique experimental data received on power fast reactors for their subsequent use in projects of fast reactors of new (4.) generation. For modeling and carrying out analysis of experiments the integrated computing system MODEXSYS has been developed. In this system the mechanism for consecutive calculation of a fast reactor states with the detailed description of its components is created. The system includes the database describing fast reactor states, results of neutron-physical characteristics measurements at fast reactor, calculation and benchmark models of experiments and calculation results. In system convenient search means and the special graphics shell are provided. It has Interfaces for processing of calculation results and their analysis. MODEXSYS system has been applied for analysis of three types of experiments at fast reactor: k{sub eff}, control rod worth and energy release distribution. The most important results of this analysis are described. Application of MODEXSYS system will raise accuracy and reliability of forecasting of fast reactors neutron-physical characteristics; for BN-600 reactor recommended level of accuracy is resulted. (authors)

  6. Neutron irradiation of V-Cr-Ti alloys in the BOR-60 fast reactor: Description of the fusion-1 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Rowcliffe, A.F. [Oak Ridge National Laboratory, TN (United States); Tsai, H.C.; Smith, D.L. [Argonne National Lab., IL (United States)] [and others

    1997-08-01

    The FUSION-1 irradiation capsule was inserted in Row 5 of the BOR-60 fast reactor in June 1995. The capsule contains a collaborative RF/U.S. experiment to investigate the irradiation performance of V-Cr-Ti alloys in the temperature range 310 to 350{degrees}C. This report describes the capsule layout, specimen fabrication history, and the detailed test matrix for the U.S. specimens. A description of the operating history and neutronics will be presented in the next semiannual report.

  7. Neutronic assessment of liquid-metal cooled fast reactors using thorium fuel

    Energy Technology Data Exchange (ETDEWEB)

    Pilarski, Stevan [Electricite de France R et D, 1 Avenue du General de Gaulle, 92141 Clamart (France); Institut de Physique Nucleaire d' Orsay, 15 rue Georges Clemenceau 91406 Orsay (France)

    2009-06-15

    The long-term sustainability of atomic fission energy will require the development of new types of reactors, able to exceed the limits of the existing ones in terms of optimal use of natural resources, which clearly necessitates breeding of fissile material. In this context, fast reactors using uranium-plutonium fuel are the most mature solution from an industrial viewpoint. In addition to the obvious interest in terms of fuel resources, there is a major incentive to consider the use of the {sup 232}Th- {sup 233}U fuel cycle as an alternative to the traditional {sup 238}U-{sup 239}Pu cycle for fast reactors: it is an effective way of addressing the safety issue of the highly positive void reactivity effect, which is a well-known problem for liquid-metal cooled fast reactors of commercial size [1]. This work investigates the performance of liquid-metal cooled fast reactors in {sup 232}Th-{sup 233}U fuel cycle and draws a comparison with the traditional {sup 238}U-{sup 239}Pu cycle. Four coolants have been considered: Na, Pb, Mg(17%at.)-Pb and Li(17%at.)-Pb; a simulation of their use in cores ranging from 700 MWth to 3600 MWth has been performed in two-dimensional diffusion theory using the European system of codes ERANOS [2,3] developed at CEA. The performance parameters such as the breeding ratio have been computed for each concept, alongside safety-related parameters: the delayed neutron fraction, the cycle reactivity swing, the Doppler constant and other thermal feedbacks. More specifically, the issue of void reactivity is studied in detail using perturbation theory. These calculations are performed at equilibrium fuel composition and are complemented by the study of the initial fuel loading at start-up which is a mixture of {sup 232}Th-{sup 239}Pu. The isotopic composition of the fissile corresponds to the plutonium available from French reactors in 2035. The conclusions of this work are that near-zero to large negative void reactivity effects can be achieved in

  8. Fast Scintillation Probes For Investigation Of Pulsed Neutron Radiation From Small Fusion Devices

    Science.gov (United States)

    Tomaszewski, Krzysztof J.

    2008-04-01

    This paper presents the design as well as laboratory/performance tests results taken by means of the fast scintillation probes. The design of each scintillation probe is based on photomultiplier tube hybrid assembly, which—besides photomultiplier itself—also includes high-voltage divider optimized for recording of fast radiation bursts. Plastic scintillators with short-time response are applied as hard X-ray and neutron radiation detectors. Heavy-duty probe's housing provides efficient shielding against electromagnetic interference and allows carrying out pulsed neutron measurements in a harsh electromagnetic environment. The crucial parameters of scintillation probes have been examined during laboratory tests in which our investigations have been aimed mainly to determine: a time response, an anode radiant sensitivity and an electron transit time dependence on high-voltage supply. During the performance tests, the relative calibration of probes set has been done. It allowed to carry out very accurate measurements of neutron emission anisotropy and investigations of neutron radiation scattering by different materials. The usefulness of presented scintillation probes—embedded in the neutron time-of-flight diagnostic system was proven during experimental campaigns conducted on the plasma-focus PF1000 device.

  9. Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

    CERN Document Server

    Osipenko, M; Ripani, M; Pillon, M; Ricco, G; Caiffi, B; Cardarelli, R; Verona-Rinati, G; Argiro, S

    2015-01-01

    A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source na...

  10. A novel fast-neutron detector concept for energy-selective imaging and imaging spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cortesi, M.; Prasser, H.-M. [Nuclear Energy and Safety Research Department, Paul Scherrer Institut, Villigen PSI 5234 (Switzerland); Mechanical Engineering Department, Swiss Federal Institute of Technology, Zurich 8092 (Switzerland); Dangendorf, V. [Ion and Neutron Radiation Department, Physikalisch-Technische Bundesanstalt, Braunschweig 38116 (Germany); Zboray, R. [Mechanical Engineering Department, Swiss Federal Institute of Technology, Zurich 8092 (Switzerland)

    2014-07-15

    We present and discuss the operational principle of a new fast-neutron detector concept suitable for either energy-selective imaging or for imaging spectroscopy. The detector is comprised of a series of energy-selective stacks of converter foils immersed in a noble-gas based mixture, coupled to a position-sensitive charge readout. Each foil in the various stacks is made of two layers of different thicknesses, fastened together: a hydrogen-rich (plastic) layer for neutron-to-proton conversion, and a hydrogen-free coating to selectively stop/absorb the recoil protons below a certain energy cut-off. The neutron-induced recoil protons, that escape the converter foils, release ionization electrons in the gas gaps between consecutive foils. The electrons are then drifted towards and localized by a position-sensitive charge amplification and readout stage. Comparison of the images detected by stacks with different energy cut-offs allows energy-selective imaging. Neutron energy spectrometry is realized by analyzing the responses of a sufficient large number of stacks of different energy response and unfolding techniques. In this paper, we present the results of computer simulation studies and discuss the expected performance of the new detector concept. Potential applications in various fields are also briefly discussed, in particularly, the application of energy-selective fast-neutron imaging for nuclear safeguards application, with the aim of determining the plutonium content in Mixed Oxide (MOX) fuels.

  11. Fast neutron tomography with real-time pulse-shape discrimination in organic scintillation detectors

    Science.gov (United States)

    Joyce, Malcolm J.; Agar, Stewart; Aspinall, Michael D.; Beaumont, Jonathan S.; Colley, Edmund; Colling, Miriam; Dykes, Joseph; Kardasopoulos, Phoevos; Mitton, Katie

    2016-10-01

    A fast neutron tomography system based on the use of real-time pulse-shape discrimination in 7 organic liquid scintillation detectors is described. The system has been tested with a californium-252 source of dose rate 163 μSv/h at 1 m and neutron emission rate of 1.5×107 per second into 4π and a maximum acquisition time of 2 h, to characterize two 100×100×100 mm3 concrete samples. The first of these was a solid sample and the second has a vertical, cylindrical void. The experimental data, supported by simulations with both Monte Carlo methods and MATLAB®, indicate that the presence of the internal cylindrical void, corners and inhomogeneities in the samples can be discerned. The potential for fast neutron assay of this type with the capability to probe hydrogenous features in large low-Z samples is discussed. Neutron tomography of bulk porous samples is achieved that combines effective penetration not possible with thermal neutrons in the absence of beam hardening.

  12. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    Science.gov (United States)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n)(3)He and D(d,n)(3)He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the (9)Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  13. Assessment of sensitivity of neutron-physical parameters of fast neutron reactor to purification of reprocessed fuel from minor actinides

    Science.gov (United States)

    Cherny, V. A.; Kochetkov, L. A.; Nevinitsa, A. I.

    2013-12-01

    The work is devoted to computational investigation of the dependence of basic physical parameters of fast neutron reactors on the degree of purification of plutonium from minor actinides obtained as a result of pyroelectrochemical reprocessing of spent nuclear fuel and used for manufacturing MOX fuel to be reloaded into the reactors mentioned. The investigations have shown that, in order to preserve such important parameters of a BN-800 type reactor as the criticality, the sodium void reactivity effect, the Doppler effect, and the efficiency of safety rods, it is possible to use the reprocessed fuel without separation of minor actinides for refueling (recharging) the core.

  14. The fast neutron SEU cross section of a 4 Mb SRAM memory

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Junior, Evaldo C.F.; Goncalez, Odair L.; Cruz, Marco Aurelio da; Prado, Adriane Cristina Mendes; Federico, Claudio Antonio; Gaspar, Felipe de Barros, E-mail: claudiofederico@ieav.cta.br, E-mail: odairlelisgoncalez@gmail.com, E-mail: evaldocarlosjr@gmail.com, E-mail: adriane.acm@hotmail.com [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil)

    2013-07-01

    The results of a static test of single event upset (SEU) produced by fast neutrons on an ISSI 4Mb SRAM memory are reported in this work. To perform the tests, it was built a platform based on a motherboard which is controlled by microprocessor, whose function is to perform the writing, reading and control of the memories under irradiation. The irradiation was performed with a set of 8 {sup 241}Am-Be neutrons source in a quasi-isotropic incidence. The SEU cross was calculated from the accumulated bit flip count. (author)

  15. Neutron cross-section libraries in the AMPX master interface format for thermal and fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, M.A.; Webster, C.C.

    1981-12-01

    Neutron cross-section libraries in the AMPX master interface format have been created for three reactor types. Included are an 84-group library for use with light-water reactors, a 27-group library for use with heavy-water CANDU reactors and a 126-group library for use with liquid metal fast breeder reactors. In general, ENDF/B data were used in the creation of these libraries, and the nuclides included in each library should be sufficient for most neutronic analyses of reactors of that type. Each library has been used successfully in fuel depletion calculations.

  16. NeuLAND MRPC-based detector prototypes tested with fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Caesar, C., E-mail: c.caesar@gsi.de [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Aumann, T. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Bemmerer, D. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); Boretzky, K. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Elekes, Z. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); ATOMKI, Debrecen (Hungary); Gonzalez-Diaz, D.; Hehner, J.; Heil, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Kempe, M. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); Maroussov, V. [Universitaet zu Koeln, Koeln (Germany); Nusair, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Al-Balqa Applied University, Salt (Jordan); Reifarth, R.; Rossi, D.; Simon, H. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Stach, D.; Wagner, A.; Yakorev, D. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); Zilges, A. [ATOMKI, Debrecen (Hungary)

    2012-01-01

    Recent results from a first irradiation of multi-gap resistive plate chambers with fast neutrons are presented. The counters have been built at GSI and FZD. The experiment was performed at the 'The Svedberg Laboratory' (TSL) in Uppsala, Sweden, utilizing a quasi-monoenergetic neutron beam with an energy E{sub n}=175 MeV. For a 2 Multiplication-Sign 4 gap prototype operated at E=100 kV/cm, an efficiency of (0.77 {+-}0.33)% was measured.

  17. Calculation of Multisphere Neutron Spectrometer Response Functions in Energy Range up to 20 MeV

    CERN Document Server

    Martinkovic, J

    2005-01-01

    Multisphere neutron spectrometer is a basic instrument of neutron measurements in the scattered radiation field at charged-particles accelerators for radiation protection and dosimetry purposes. The precise calculation of the spectrometer response functions is a necessary condition of the propriety of neutron spectra unfolding. The results of the response functions calculation for the JINR spectrometer with LiI(Eu) detector (a set of 6 homogeneous and 1 heterogeneous moderators, "bare" detector within cadmium cover and without it) at two geometries of the spectrometer irradiation - in uniform monodirectional and uniform isotropic neutron fields - are given. The calculation was carried out by the code MCNP in the neutron energy range 10$^{-8}$-20 MeV.

  18. Time-resolved fast-neutron pinhole camera for studying thermonuclear plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, R.W.; Weingart, R.C.

    1976-02-02

    A fast-neutron pinhole camera with high detection efficiency and nanosecond time-resolution has been developed and applied to the investigation of the spatial and temporal distributions of DD- and DT-neutrons produced by thermonuclear plasmas. The pinhole consists of a specially designed 1.15 m long copper collimator with an effective aperture of 1 mm diameter. Several different types of spatial resolution detectors have been used at the image plane: (1) a multi-element, scintillation-photomultiplier system used for time-resolved measurements consisting of sixty-one individual detectors, (2) a scintillation-fiber-chamber coupled to a gated image-intensifier tube used for direct photographing of the neutron image, and (3) a propane bubble chamber used for time-integrated recording with a capability to distinguish DD- from DT-neutrons. Pulsed neutron sources with typical dimensions of 1 cm emitting of the order of 10/sup 12/ neutrons over a time period of 10-100 nsec have been investigated. A spatial resolution of 1 mm and a time resolution of approximately 10 nsec was achieved in the investigations of dense plasma compression phenomena.

  19. Neutron, electron and photon transport in ICF tragets in direct and fast ignition

    Directory of Open Access Journals (Sweden)

    A. Parvazian

    2005-12-01

    Full Text Available Fusion energy due to inertial confinement has progressed in the last few decades. In order to increase energy efficiency in this method various designs have been presented. The standard scheme for direct ignition and fast ignition fuel targets are considered. Neutrons, electrons and photons transport in targets containing different combinations of Li and Be are calculated in both direct and fast ignition schemes. To compress spherical multilayer targets having fuel in the central part, they are irradiated by laser or heavy ion beams. Neutrons energy deposition in the target is considered using Monte Carlo method code MCNP. A significant amount of neutrons energy is deposited in the target which resulted in growing fusion reactions rates. It is found that Beryllium compared to Lithium is more important. In an introductory consideration of relativistic electron beam transport into central part of a fast ignition target, we have calculated electron energy deposition in highly dense D-T fuel and Beryllium layer of the target. It has been concluded that a fast ignition scheme is preferred to direct ignition because of the absence of hydrodynamic instability.

  20. Estimation of fast neutron fluence in steel specimens type Laguna Verde in TRIGA Mark III reactor; Estimacion de la fluencia de neutrones rapidos en probetas de acero tipo Laguna Verde en el reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Galicia A, J.; Francois L, J. L. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Aguilar H, F., E-mail: blink19871@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    The main purpose of this work is to obtain the fluence of fast neutrons recorded within four specimens of carbon steel, similar to the material having the vessels of the BWR reactors of the nuclear power plant of Laguna Verde when subjected to neutron flux in a experimental facility of the TRIGA Mark III reactor, calculating an irradiation time to age the material so accelerated. For the calculation of the neutron flux in the specimens was used the Monte Carlo code MCNP5. In an initial stage, three sheets of natural molybdenum and molybdenum trioxide (MoO{sub 3}) were incorporated into a model developed of the TRIGA reactor operating at 1 M Wth, to calculate the resulting activity by setting a certain time of irradiation. The results obtained were compared with experimentally measured activities in these same materials to validate the calculated neutron flux in the model used. Subsequently, the fast neutron flux received by the steel specimens to incorporate them in the experimental facility E-16 of the reactor core model operating at nominal maximum power in steady-state was calculated, already from these calculations the irradiation time required was obtained for values of the neutron flux in the range of 10{sup 18} n/cm{sup 2}, which is estimated for the case of Laguna Verde after 32 years of effective operation at maximum power. (Author)

  1. The optimisation of the fast neutron and gamma-ray transmission set-up for moisture measurement of coke.

    Science.gov (United States)

    Cywicka-Jakiel, T; Łoskiewicz, J; Tracz, G

    2003-01-01

    In the present paper, modelling calculations with the Monte Carlo (MCNP4C) code were performed for the optimisation of the fast neutron and gamma-ray transmission, set-up, used for the humidity measurement of coke. The optimisation focused on maximising the sensitivity of the neutron flux to humidity changes and on lowering neutron-counting error, both leading to higher accuracy of coke moisture determination. Different materials used for the source shielding and neutron collimation, together with different dimensions of the neutron collimators were studied. The results obtained from the Monte Carlo modelling correlate with the real instrument performance.

  2. Understanding fast neutrons utilizing a water Cherenkov detector and a gas-filled detector at the soudan underground laboratory

    Science.gov (United States)

    Ghimire, Chiranjibi

    Many experiments are currently searching for Weakly Interactive Massive Particles (WIMPs), a well-motivated class of hypothetical dark matter candidates. These direct dark matter detection experiments are located in deep underground to shield from cosmic-ray muons and the fast neutrons they produce. Fast neutrons are particularly dangerous to WIMP detectors because they can penetrate a WIMP-search experiment's neutron shielding. Once inside, these fast neutrons can interact with high-Z material near the WIMP detector, producing slower neutrons capable of mimicking the expected WIMP signal. My research uses two detectors located in Soudan Underground Laboratory to understand fast neutron production by muons in an underground environment: a water-Cherenkov detector sensitive to fast neutrons; and a gas-filled detector sensitive to charged particles like muons. The different kinds of selection criterion and their efficiencies are reported in this thesis. This thesis estimate the number of high energy neutron-like candidates associated with a nearby muon by using data from both detector systems.

  3. Used fuel storage monitoring using novel 4He scintillation fast neutron detectors and neutron energy discrimination analysis

    Science.gov (United States)

    Kelley, Ryan P.

    With an increasing quantity of spent nuclear fuel being stored at power plants across the United States, the demand exists for a new method of cask monitoring. Certifying these casks for transportation and long-term storage is a unique dilemma: their sealed nature lends added security, but at the cost of requiring non-invasive measurement techniques to verify their contents. This research will design and develop a new method of passively scanning spent fuel casks using 4He scintillation detectors to make this process more accurate. 4He detectors are a relatively new technological development whose full capabilities have not yet been exploited. These detectors take advantage of the high 4He cross section for elastic scattering at fast neutron energies, particularly the resonance around 1 MeV. If one of these elastic scattering interactions occurs within the detector, the 4He nucleus takes energy from the incident neutron, then de-excites by scintillation. Photomultiplier Tubes (PMTs) at either end of the detector tube convert this emitted light into an electrical signal. The goal of this research is to use the neutron spectroscopy features of 4He scintillation detectors to maintain accountability of spent fuel in storage. This project will support spent fuel safeguards and the detection of fissile material, in order to minimize the risk of nuclear proliferation and terrorism.

  4. Development of detector for neutron monitor of wide energy range. Joint research

    CERN Document Server

    Kim, E; Nakamura, T; Rasolonjatovo, D R D; Shiomi, T; Tanaka, S; Yamaguchi, Y; Yoshizawa, M

    2002-01-01

    Radiation monitoring of neutrons in high-power proton accelerator facilities is very important for radiation safety management for workers and members of the public. In the present study, a neutron detector that can evaluate dose of neutrons in the energy range from thermal energy to 100MeV was developed using an organic liquid scintillator, a boron-loaded scintillator and a sup 6 Li glass scintillator. First, a method was developed to evaluate neutron doses above several MeV by a spectrum weight function (G-function) which is applied to the organic liquid scintillator, and the validity of the methods was confirmed by dose evaluation in some neutron fields. Second, the G-function was applied to the boron-loaded scintillator which detects thermal neutrons by sup 1 sup 0 B(n, alpha) sup 7 Li reaction, in order to expand the covering neutron energy range. The response function and the G-function of the scintillator were evaluated by experiment and calculation, and the characteristics of dose measurement were ana...

  5. Use of CR 39 Films for Evaluation of Shielding Efficacy of Materials against Fast Neutrons

    Directory of Open Access Journals (Sweden)

    S. Kumar

    1992-10-01

    Full Text Available CR-39 films have been used for evaluation of neutron shielding of metal alloys, different types of rubbers, sand polymers, etc. These films have been chosen because of their ability to record fast neutrons from 200 keV-10 MeV and their insensitivity to gamma radiations. Tenth value layer (TVL for the materials studied varies from 10.5 to 28.6 cm. In addition, the values of TVL have also been computed for standard material, such as Al, steel, etc. Using neutron removal cross-section data, the results have been compared with those of experimentally determined values. The results seem to be in agreement within approximate 10 per cent variation.

  6. Quantification of the sensitivity range in neutron dark-field imaging

    Energy Technology Data Exchange (ETDEWEB)

    Betz, B.; Harti, R. P.; Hovind, J.; Kaestner, A.; Lehmann, E.; Grünzweig, C. [Paul Scherrer Institute, LNS, Neutron Imaging and Activation Group, CH-5232 Villigen (Switzerland); Strobl, M. [European Spallation Source ESS, 22100 Lund, Sweden and University of Copenhagen, 2100 Copenhagen (Denmark); Van Swygenhoven, H. [Ecole Polytechnique Fédérale de Lausanne, NXMM Laboratory, IMX, CH-1015 Lausanne, Switzerland and Paul Scherrer Institut, NXMM, CH-5232 Villigen (Switzerland)

    2015-12-15

    In neutron grating interferometry, the dark-field image visualizes the scattering properties of samples in the small-angle and ultra-small-angle scattering range. These angles correspond to correlation lengths from several hundred nanometers up to several tens of micrometers. In this article, we present an experimental study that demonstrates the potential of quantitative neutron dark-field imaging. The dark-field signal for scattering from different particle sizes and concentrations of mono-dispersive polystyrene particles in aqueous solution is compared to theoretical predictions and the good agreement between measurements and calculations underlines the quantitative nature of the measured values and reliability of the technique with neutrons.

  7. Capturing 3D Water Flow in Rooted Soil by Ultra-fast Neutron Tomography.

    Science.gov (United States)

    Tötzke, Christian; Kardjilov, Nikolay; Manke, Ingo; Oswald, Sascha E

    2017-07-21

    Water infiltration in soil is not only affected by the inherent heterogeneities of soil, but even more by the interaction with plant roots and their water uptake. Neutron tomography is a unique non-invasive 3D tool to visualize plant root systems together with the soil water distribution in situ. So far, acquisition times in the range of hours have been the major limitation for imaging 3D water dynamics. Implementing an alternative acquisition procedure we boosted the speed of acquisition capturing an entire tomogram within 10 s. This allows, for the first time, tracking of a water front ascending in a rooted soil column upon infiltration of deuterated water time-resolved in 3D. Image quality and resolution could be sustained to a level allowing for capturing the root system in high detail. Good signal-to-noise ratio and contrast were the key to visualize dynamic changes in water content and to localize the root uptake. We demonstrated the ability of ultra-fast tomography to quantitatively image quick changes of water content in the rhizosphere and outlined the value of such imaging data for 3D water uptake modelling. The presented method paves the way for time-resolved studies of various 3D flow and transport phenomena in porous systems.

  8. Morphology of fast-tumbling bicelles: a small angle neutron scattering and NMR study.

    Science.gov (United States)

    Luchette, P A; Vetman, T N; Prosser, R S; Hancock, R E; Nieh, M P; Glinka, C J; Krueger, S; Katsaras, J

    2001-08-06

    Bilayered micelles, or bicelles, which consist of a mixture of long- and short-chain phospholipids, are a popular model membrane system. Depending on composition, concentration, and temperature, bicelle mixtures may adopt an isotropic phase or form an aligned phase in magnetic fields. Well-resolved (1)H NMR spectra are observed in the isotropic or so-called fast-tumbling bicelle phase, over the range of temperatures investigated (10-40 degrees C), for molar ratios of long-chain lipid to short-chain lipid between 0.20 and 1.0. Small angle neutron scattering data of this phase are consistent with the model in which bicelles were proposed to be disk-shaped. The experimentally determined dimensions are roughly consistent with the predictions of R.R. Vold and R.S. Prosser (J. Magn. Reson. B 113 (1996)). Differential paramagnetic shifts of head group resonances of dimyristoylphosphatidylcholine (DMPC) and dihexanoylphosphatidylcholine (DHPC), induced by the addition of Eu(3+), are also consistent with the bicelle model in which DHPC is believed to be primarily sequestered to bicelle rims. Selective irradiation of the DHPC aliphatic methyl resonances results in no detectable magnetization transfer to the corresponding DMPC methyl resonances (and vice versa) in bicelles, which also suggests that DHPC and DMPC are largely sequestered in the bicelle. Finally, (1)H spectra of the antibacterial peptide indolicidin (ILPWKWPWWPWRR-NH(2)) are compared, in a DPC micellar phase and the above fast-tumbling bicellar phases for a variety of compositions. The spectra exhibit adequate resolution and improved dispersion of amide and aromatic resonances in certain bicelle mixtures.

  9. Structure and Spatial Distribution of Ge Nanocrystals Subjected to Fast Neutron Irradiation

    Directory of Open Access Journals (Sweden)

    Alexander N. Ionov

    2011-07-01

    Full Text Available The influence of fast neutron irradiation on the structure and spatial distribution of Ge nanocrystals (NC embedded in an amorphous SiO2 matrix has been studied. The investigation was conducted by means of laser Raman Scattering (RS, High Resolution Transmission Electron Microscopy (HR-TEM and X-ray photoelectron spectroscopy (XPS. The irradiation of Ge- NC samples by a high dose of fast neutrons lead to a partial destruction of the nanocrystals. Full reconstruction of crystallinity was achieved after annealing the radiation damage at 8000C, which resulted in full restoration of the RS spectrum. HR-TEM images show, however, that the spatial distributions of Ge-NC changed as a result of irradiation and annealing. A sharp decrease in NC distribution towards the SiO2 surface has been observed. This was accompanied by XPS detection of Ge oxides and elemental Ge within both the surface and subsurface region.

  10. Influence of rapid thermal process on intrinsic gettering in fast neutron irradiated Czochralski silicon

    Institute of Scientific and Technical Information of China (English)

    CHEN Gui-feng; LI Yang-xian; LI Xing-hua; CAI Li-li; MA Qiao-yun; NIU Ping-juan; NIU Sheng-li; CHEN Dong-feng

    2006-01-01

    A rapid thermal process (RTP) was first introduced into the intrinsic gettering (IG) processes of fast neutron irradiated Czochralski (CZ) silicon. The effect of RTP conditions on bulk microdefects (BMDs) and denuded zone (DZ) was investigated. Fourier transform infrared absorption spectrometer (FTIR) was used to measure the concentration of interstitial oxygen ([Oi]). Bulk microdefects were observed by optical microscope. The results show that,according to the variation of [Oi],it is found that RTP doesn't change the processes of oxygen precipitation in fast neutron irradiated Czochralski silicon. Perfect denuded zone,dense oxygen precipitates and defects form in the bulk of irradiated samples. With increasing temperature of RTP,the width of denuded zone decreases. Increasing RTP cooling rate,the density of Bulk microdefects increases. DZ forms in the sample that annealed in nitrogen atmosphere.

  11. Time-resolved Fast Neutron Radiography of Air-water Two-phase Flows

    Science.gov (United States)

    Zboray, Robert; Dangendorf, Volker; Mor, Ilan; Tittelmeier, Kai; Bromberger, Benjamin; Prasser, Horst-Michael

    Neutron imaging, in general, is a useful technique for visualizing low-Z materials (such as water or plastics) obscured by high-Z materials. However, when significant amounts of both materials are present and full-bodied samples have to be examined, cold and thermal neutrons rapidly reach their applicability limit as the samples become opaque. In such cases one can benefit from the high penetrating power of fast neutrons. In this work we demonstrate the feasibility of time-resolved, fast neutron radiography of generic air-water two-phase flows in a 1.5 cm thick flow channel with Aluminum walls and rectangular cross section. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany. Exposure times down to 3.33 ms have been achieved at reasonable image quality and acceptable motion artifacts. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two-phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured.

  12. Fast rotation of neutron stars and equation of state of dense matter

    CERN Document Server

    Haensel, P; Bejger, M

    2008-01-01

    Fast rotation of compact stars (at submillisecond period) and, in particular, their stability, are sensitive to the equation of state (EOS) of dense matter. Recent observations of XTE J1739-285 suggest that it contains a neutron star rotating at 1122 Hz (Kaaret et al. 2007). At such rotational frequency the effects of rotation on star's structure are significant. We study the interplay of fast rotation, EOS and gravitational mass of a submillisecond pulsar. We discuss the EOS dependence of spin-up to a submillisecond period, via mass accretion from a disk in a low-mass X-ray binary.

  13. A unified Monte Carlo approach to fast neutron cross section data evaluation.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.; Nuclear Engineering Division

    2008-03-03

    A unified Monte Carlo (UMC) approach to fast neutron cross section data evaluation that incorporates both model-calculated and experimental information is described. The method is based on applications of Bayes Theorem and the Principle of Maximum Entropy as well as on fundamental definitions from probability theory. This report describes the formalism, discusses various practical considerations, and examines a few numerical examples in some detail.

  14. A fast Monte Carlo program for pulsed-neutron capture-gamma tools

    Energy Technology Data Exchange (ETDEWEB)

    Hovgaard, J.

    1992-02-01

    A fast model for the pulsed-neutron capture-gamma tool has been developed. It is believed that the program produce valid results even though some approximation have been introduced. A correct {gamma} photon transport simulation, which is under preparation, has for instance not yet been included. Simulations performed so far has shown that the model, with respect to computing time and accuracy, fully lives up to expectations with respect to computing time and accuracy. (au).

  15. A fast Monte Carlo program for pulsed-neutron capture-gamma tools

    Energy Technology Data Exchange (ETDEWEB)

    Hovgaard, J.

    1992-02-01

    A fast model for the pulsed-neutron capture-gamma tool has been developed. It is believed that the program produce valid results even though some approximation have been introduced. A correct [gamma] photon transport simulation, which is under preparation, has for instance not yet been included. Simulations performed so far has shown that the model, with respect to computing time and accuracy, fully lives up to expectations with respect to computing time and accuracy. (au).

  16. Measurements of effective delayed neutron fraction in a fast neutron reactor using the perturbation method

    CERN Document Server

    Zhou, Hao-Jun; Fan, Xiao-Qiang; Li, Zheng-Hong; Pu, Yi-Kang

    2015-01-01

    The perturbation method is proposed to obtain the effective delayed neutron fraction (\\b{eta}eff) of a cylindrical highly enriched uranium reactor. Based on the reactivity measurements with and without a sample at a designable position using the positive periodic technique, the reactor reactivity perturbation {\\Delta}\\r{ho} of the sample in \\b{eta}eff units is measured. The simulation of the perturbation experiments are performed by MCNP program. The PERT card is used to provide the difference dk of effective neutron multiplication factors with and without the sample inside the reactor. Based on the relationship between the effective multiplication factor and the reactivity, the equation \\b{eta}eff =dk/{\\Delta}\\r{ho} is derived. In this paper, the reactivity perturbations of 13 metal samples at the designable position of the reactor are measured and calculated. The average \\b{eta}eff value of the reactor is given as 0.00645, and the standard uncertainty is 3.0%. Additionally, the perturbation experiments for ...

  17. Pulse shape discrimination between (fast or thermal) neutrons and gamma rays with plastic scintillators: State of the art

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, Guillaume H.V. [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France); Hamel, Matthieu, E-mail: matthieu.hamel@cea.fr [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France); Normand, Stéphane [CEA, DAM, Le Ponant, 25 rue Leblanc, F-75015 Paris (France); Sguerra, Fabien [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France)

    2015-03-11

    We would like to present here with the eyes of the chemist the most recent developments of plastic scintillators (PS) for neutron detection. This review covers the period from 2000 to August 2014, and is fragmented in two main chapters. The first chapter deals with the chemical modifications for thermal neutron capture, whereas the second chapter presents the various strategies used to enhance the response to fast neutrons via pulse shape discrimination. For each chapter the theory is also explained.

  18. The effects of fast neutron irradiation on oxygen in Czochralski silicon

    Institute of Scientific and Technical Information of China (English)

    Chen Gui-Feng; Yan Wen-Bo; Chen Hong-Jian; Li Xing-Hua; Li Yang-Xian

    2009-01-01

    The effects of fast neutron irradiation on oxygen atoms in Czochralski silicon (CZ-Si) are investigated systemically by using Fourier transform infrared (FTIR) spectrometer and positron annihilation technique (PAT). Through isochronal annealing, it is found that the trend of variation in interstitial oxygen concentration ([Oi]) in fast neutrons irradiated CZ-Si fluctuates largely with temperature increasing, especially between 500 and 700℃. After the CZ-Si is annealed at 600℃, the V4 appearing as three-dimensional vacancy clusters causes the formation of the molecule-like oxygen clusters, and more importantly these dimers with small binding energies (0.1-1.0eV) can diffuse into the Si lattices more easily than single oxygen atoms, thereby leading to the strong oxygen agglomerations. When the CZ-Si is annealed at temperature increasing up to 700℃, three-dimensional vacancy clusters disappear and the oxygen agglomerations decompose into single oxygen atoms (O) at interstitial sites. Results from FTIR spectrometer and PAT provide an insight into the nature of the [Oi] at temperatures between 500 and 700℃. It turns out that the large fluctuation of [Oi] after short-time annealing from 500 to 700℃ results from the transformation of fast neutron irradiation defects.

  19. A novel approach to correct the coded aperture misalignment for fast neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, F. N.; Hu, H. S., E-mail: huasi-hu@mail.xjtu.edu.cn; Wang, D. M.; Jia, J. [School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Zhang, T. K. [Laser Fusion Research Center, CAEP, Mianyang, 621900 Sichuan (China); Jia, Q. G. [Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China)

    2015-12-15

    Aperture alignment is crucial for the diagnosis of neutron imaging because it has significant impact on the coding imaging and the understanding of the neutron source. In our previous studies on the neutron imaging system with coded aperture for large field of view, “residual watermark,” certain extra information that overlies reconstructed image and has nothing to do with the source is discovered if the peak normalization is employed in genetic algorithms (GA) to reconstruct the source image. Some studies on basic properties of residual watermark indicate that the residual watermark can characterize coded aperture and can thus be used to determine the location of coded aperture relative to the system axis. In this paper, we have further analyzed the essential conditions for the existence of residual watermark and the requirements of the reconstruction algorithm for the emergence of residual watermark. A gamma coded imaging experiment has been performed to verify the existence of residual watermark. Based on the residual watermark, a correction method for the aperture misalignment has been studied. A multiple linear regression model of the position of coded aperture axis, the position of residual watermark center, and the gray barycenter of neutron source with twenty training samples has been set up. Using the regression model and verification samples, we have found the position of the coded aperture axis relative to the system axis with an accuracy of approximately 20 μm. Conclusively, a novel approach has been established to correct the coded aperture misalignment for fast neutron coded imaging.

  20. High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel

    CERN Document Server

    Zboray, R; Dangendorf, V; Stark, M; Tittelmeier, K; Cortesi, M; Adams, R

    2015-01-01

    We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.

  1. Solid polystyrene and deuterated polystyrene light output response to fast neutrons

    Science.gov (United States)

    Simpson, R.; Danly, C.; Glebov, V. Yu.; Hurlbut, C.; Merrill, F. E.; Volegov, P. L.; Wilde, C.

    2016-04-01

    The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. The current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two [L. Disdier et al., Rev. Sci. Instrum. 75, 2134 (2004)], but also a reduction in light output [V. Bildstein et al., Nucl. Instrum. Methods Phys. Res., Sect. A 729, 188 (2013); M. I. Ojaruega, Ph.D. thesis, University of Michigan, 2009; M. T. Febbraro, Ph.D. thesis, University of Michigan, 2014] as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.

  2. Investigation of Fast Neutron Production by 100 to 250~GeV Muon Interactions on Thin Targets

    CERN Multimedia

    2002-01-01

    % NA55 \\\\ \\\\ The production of fast (1~MeV~-~1~GeV) neutrons in high energy muon-nucleon interactions is poorly understood. Yet it is essential to the understanding of the background in many underground neutrino experiments and, in particular, may hold relevance for the atmospheric neutrino anomaly. We propose an experiment to investigate fast neutron production using the M2 muon beam at the CERN SPS.

  3. A digital wide range neutron flux measuring system for HL-2A

    Science.gov (United States)

    Yuan, Chen; Wu, Jun; Yin, Zejie

    2017-08-01

    To achieve wide-range, high-integration, and real-time performance on the neutron flux measurement on the HL-2A tokamak, a digital neutron flux measuring (DNFM) system based on the peripheral component interconnection (PCI) eXtension for Instrumentation express (PXIe) bus was designed. This system comprises a charge-sensitive preamplifier and a field programmable gate array (FPGA)-based main electronics plug-in. The DNFM totally covers source-range and intermediate-range neutron flux measurements, and increases system integration by a large margin through joining the pulse-counting mode and Campbell mode. Meanwhile, the neutron flux estimation method based on pulse piling proportions is able to choose and switch measuring modes in accordance with current flux, and this ensures the accuracy of measurements when the neutron flux changes suddenly. It has been demonstrated by simulated signals that the DNFM enhances the full-scale measuring range up to 1.9 × 108 cm-2 s-1, with relative error below 6.1%. The DNFM has been verified to provide a high temporal sensitivity at 10 ms time intervals on a single fission chamber on HL-2A. Contributed paper, published as part of the Proceedings of the 3rd Domestic Electromagnetic Plasma Diagnostics Workshop, September 2016, Hefei, China.

  4. MCNPX simulations of the silicon carbide semiconductor detector response to fast neutrons from D-T nuclear reaction

    Science.gov (United States)

    Sedlačková, Katarína; Šagátová, Andrea; Zat'ko, Bohumír; Nečas, Vladimír; Solar, Michael; Granja, Carlos

    2016-09-01

    Silicon Carbide (SiC) has been long recognized as a suitable semiconductor material for use in nuclear radiation detectors of high-energy charged particles, gamma rays, X-rays and neutrons. The nuclear interactions occurring in the semiconductor are complex and can be quantified using a Monte Carlo-based computer code. In this work, the MCNPX (Monte Carlo N-Particle eXtended) code was employed to support detector design and analysis. MCNPX is widely used to simulate interaction of radiation with matter and supports the transport of 34 particle types including heavy ions in broad energy ranges. The code also supports complex 3D geometries and both nuclear data tables and physics models. In our model, monoenergetic neutrons from D-T nuclear reaction were assumed as a source of fast neutrons. Their energy varied between 16 and 18.2 MeV, according to the accelerating voltage of the deuterons participating in D-T reaction. First, the simulations were used to calculate the optimum thickness of the reactive film composed of High Density PolyEthylene (HDPE), which converts neutral particles to charged particles and thusly enhancing detection efficiency. The dependency of the optimal thickness of the HDPE layer on the energy of the incident neutrons has been shown for the inspected energy range. Further, from the energy deposited by secondary charged particles and recoiled ions, the detector response was modeled and the effect of the conversion layer on detector response was demonstrated. The results from the simulations were compared with experimental data obtained for a detector covered by a 600 and 1300 μm thick conversion layer. Some limitations of the simulations using MCNPX code are also discussed.

  5. Self powered neutron detectors as in-core detectors for Sodium-cooled Fast Reactors

    Science.gov (United States)

    Verma, V.; Barbot, L.; Filliatre, P.; Hellesen, C.; Jammes, C.; Svärd, S. Jacobsson

    2017-07-01

    Neutron flux monitoring system forms an integral part of the design of a Generation IV sodium cooled fast reactor. Diverse possibilities of detector system installation must be studied for various locations in the reactor vessel in order to detect any perturbations in the core. Results from a previous paper indicated that it is possible to detect changes in neutron source distribution initiated by an inadvertent withdrawal of outer control rod with in-vessel fission chambers located azimuthally around the core. It is, however, not possible to follow inner control rod withdrawal and precisely know the location of the perturbation in the core. Hence the use of complimentary in-core detectors coupled with the peripheral fission chambers is proposed to enable robust core monitoring across the radial direction. In this paper, we assess the feasibility of using self-powered neutron detectors (SPNDs) as in-core detectors in fast reactors for detecting local changes in the power distribution when the reactor is operated at nominal power. We study the neutron and gamma contributions to the total output current of the detector modelled with Platinum as the emitter material. It is shown that this SPND placed in an SFR-like environment would give a sufficiently measurable prompt neutron induced current of the order of 600 nA/m. The corresponding induced current in the connecting cable is two orders of magnitude lower and can be neglected. This means that the SPND can follow in-core power fluctuations. This validates the operability of an SPND in an SFR-like environment.

  6. Enhancement of critical current density in fast neutron irradiated melt-textured YBa 2Cu 3O 7- x

    Science.gov (United States)

    Puźniak, R.; Wiśniewski, A.; Baran, M.; Szymczak, H.; Pingxiang, Zhang; Jingrong, Wang; Lian, Zhou; Pytel, K.; Pytel, B.

    The critical current density in melt-textured samples obtained by the powder melting process was determined from magnetization measurements. Linear dependence between the width of the hysteresis loop and sample size was observed for both unirradiated and irradiated samples. This indicates that the critical current is circulating through the whole sample and is not disconnected by weak links, even when a magnetic field is applied in the irradiated sample. After fast neutron irradiation with fluences from 5 × 10 16 to 6 × 10 17 n cm -2 ( E > 0.5 MeV), significant enhancement of the critical current density, jc, was observed. Critical current density, determined from magnetization measurements, for magnetic field perpendicular to the a-b plane, jcab, reaches - 10 5 A cm 42 at 77 K in 1 T. For H parallel to the a-b plane, jcc along the c-axis reaches 5 × 10 3 A cm -2. An increase in the anisotropy of the critical current was observed after fast neutron irradiation in the temperature range 60 - 80 K.

  7. Soil water content determination with cosmic-ray neutron sensor: Correcting aboveground hydrogen effects with thermal/fast neutron ratio

    Science.gov (United States)

    Tian, Zhengchao; Li, Zizhong; Liu, Gang; Li, Baoguo; Ren, Tusheng

    2016-09-01

    The cosmic-ray neutron sensor (CRNS), which estimates field scale soil water content, bridges the gap between point measurement and remote sensing. The accuracy of CRNS measurements, however, is affected by additional hydrogen pools (e.g., vegetation, snow, and rainfall interception). The objectives of this study are to: (i) evaluate the accuracy of CRNS estimates in a farmland system using depth and horizontal weighted point measurements, (ii) introduce a novel method for estimating the amounts of hydrogen from biomass and snow cover in CRNS data, and (iii) propose a simple approach for correcting the influences of aboveground hydrogen pool (expressed as aboveground water equivalent, AWE) on CRNS measurements. A field experiment was conducted in northeast China to compare soil water content results from CRNS to in-situ data with time domain reflectometry (TDR) and neutron probe (NP) in the 0-40 cm soil layers. The biomass water equivalent (BWE) and snow water equivalent (SWE) were observed to have separate linear relationships with the thermal/fast neutron ratio, and the dynamics of BWE and SWE were estimated correctly in the crop seasons and snow-covered seasons, respectively. A simple approach, which considered the AWE, AWE at calibration, and the effective measurement depth of CRNS, was introduced to correct the errors caused by BWE and SWE. After correction, the correlation coefficients between soil water contents determined by CRNS and TDR were 0.79 and 0.77 during the 2014 and 2015 crop seasons, respectively, and CRNS measurements had RMSEs of 0.028, 0.030, and 0.039 m3 m-3 in the 2014 and 2015 crop seasons and the snow-covered seasons, respectively. The experimental results also indicated that the accuracies of CRNS estimated BWE and SWE were affected by the distributions of aboveground hydrogen pools, which were related to the height of the CRNS device above ground surface.

  8. Radiation hardness tests of piezoelectric actuators with fast neutrons at liquid helium temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fouaidy, M.; Martinet, G.; Hammoudi, N.; Chatelet, F.; Olivier, A.; Blivet, S.; Galet, F. [CNRS-IN2P3-IPN Orsay, Orsay (France)

    2007-07-01

    Piezoelectric actuators, which are integrated into the cold tuning system and used to compensate the small mechanical deformations of the cavity wall induced by Lorentz forces due to the high electromagnetic surface field, may be located in the radiation environment during particle accelerator operation. In order to provide for a reliable operation of the accelerator, the performance and life time of piezoelectric actuators ({approx}24.000 units for ILC) should not show any significant degradation for long periods (i.e. machine life duration: {approx}20 years), even when subjected to intense radiation (i.e. gamma rays and fast neutrons). An experimental program, aimed at investigating the effect of fast neutrons radiation on the characteristics of piezoelectric actuators at liquid helium temperature (i.e. T{approx}4.2 K), was proposed for the working package WPNo.8 devoted to tuners development in the frame of CARE project. A neutrons irradiation facility, already installed at the CERI cyclotron located at Orleans (France), was upgraded and adapted for actuators irradiations tests purpose. A deuterons beam (maximum energy and beam current: 25 MeV and 35{mu}A) collides with a thin (thickness: 3 mm) beryllium target producing a high neutrons flux with low gamma dose ({approx}20%): a neutrons fluence of more than 10{sup 14} n/cm{sup 2} is achieved in {approx}20 hours of exposure. A dedicated cryostat was developed at IPN Orsay and used previously for radiation hardness test of calibrated cryogenic thermometers and pressure transducers used in LHC superconducting magnets. This cryostat could be operated either with liquid helium or liquid argon. This irradiation facility was upgraded for allowing fast turn-over of experiments and a dedicated experimental set-up was designed, fabricated, installed at CERI and successfully operated for radiation hardness tests of several piezoelectric actuators at T{approx}4.2 K. This new apparatus allows on-line automatic measurements

  9. Sustainable thorium nuclear fuel cycles: A comparison of intermediate and fast neutron spectrum systems

    Energy Technology Data Exchange (ETDEWEB)

    Brown, N.R., E-mail: nbrown@bnl.gov [Brookhaven National Laboratory, Upton, NY (United States); Powers, J.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Feng, B.; Heidet, F.; Stauff, N.E.; Zhang, G. [Argonne National Laboratory, Argonne, IL (United States); Todosow, M. [Brookhaven National Laboratory, Upton, NY (United States); Worrall, A.; Gehin, J.C. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Kim, T.K.; Taiwo, T.A. [Argonne National Laboratory, Argonne, IL (United States)

    2015-08-15

    Highlights: • Comparison of intermediate and fast spectrum thorium-fueled reactors. • Variety of reactor technology options enables self-sustaining thorium fuel cycles. • Fuel cycle analyses indicate similar performance for fast and intermediate systems. • Reproduction factor plays a significant role in breeding and burn-up performance. - Abstract: This paper presents analyses of possible reactor representations of a nuclear fuel cycle with continuous recycling of thorium and produced uranium (mostly U-233) with thorium-only feed. The analysis was performed in the context of a U.S. Department of Energy effort to develop a compendium of informative nuclear fuel cycle performance data. The objective of this paper is to determine whether intermediate spectrum systems, having a majority of fission events occurring with incident neutron energies between 1 eV and 10{sup 5} eV, perform as well as fast spectrum systems in this fuel cycle. The intermediate spectrum options analyzed include tight lattice heavy or light water-cooled reactors, continuously refueled molten salt reactors, and a sodium-cooled reactor with hydride fuel. All options were modeled in reactor physics codes to calculate their lattice physics, spectrum characteristics, and fuel compositions over time. Based on these results, detailed metrics were calculated to compare the fuel cycle performance. These metrics include waste management and resource utilization, and are binned to accommodate uncertainties. The performance of the intermediate systems for this self-sustaining thorium fuel cycle was similar to a representative fast spectrum system. However, the number of fission neutrons emitted per neutron absorbed limits performance in intermediate spectrum systems.

  10. Relative biological effectiveness of fast neutrons in a multiorgan assay for apoptosis in mouse.

    Science.gov (United States)

    Lee, Hae-June; Kim, Joong-Sun; Moon, Changjong; Kim, Jong-Choon; Jo, Sung-Kee; Kim, Sung-Ho

    2008-04-01

    This study compared the effects of high linear energy transfer (LET) fast neutrons on the induction of apoptosis in several tissue types (hair follicle, intestine crypt, testis) of ICR mouse exposed to low LET 60Co gamma-rays. The changes that occurred from 0 to 24 h after exposing the mice to either 2 Gy of gamma-rays (2 Gy/min) or 0.8 Gy of neutrons (94 mGy/min, 35 MeV) were examined. The maximum frequency of apoptosis was observed at 8 or 12 h after irradiation. The mice that had received 0-8 Gy of gamma-rays or 0-1.6 Gy of neutrons were examined 8 h after irradiation. The best-fitting dose-response curves were linear-quadratic, and there was a significant relationship between the number of apoptotic cells and the dose. The stained products in the TUNEL-positive cells or bodies correlated with the typical morphologic characteristics of apoptosis observed by optical microscopy. In the follicles showing an apoptosis frequency between 2 and 14 per hair follicle, the relative biological effectiveness (RBE) of the neutrons in the small and large follicles was 2.09 +/- 0.31 and 2.15 +/- 0.18, respectively. In the intestine crypts showing an apoptosis frequency between 1 and 3 per crypt, the RBE of the neutrons was 4.03 +/- 0.06 and 3.87 +/- 0.04 in the base and total crypts, respectively. The RBE of the neutrons in the seminiferous tubule showing an apoptosis frequency between 0.5 and 2 per tubule was 5.18 +/- 0.06. The results determined the time-response relations and the RBE for fast neutron-induced apoptosis in several organs at the same time. The differences in RBE observed between the high and low LET radiation and it is believed that the difference in the DSB repair capacity in hair follicle, intestine crypt, and seminiferous tubule cells plays a role in determining the RBE of the high-LET radiation for the induced apoptotic cell formation.

  11. Computed Tomography with X-rays and Fast Neutrons for Restoration of Wooden Artwork

    Science.gov (United States)

    Osterloh, Kurt; Bellon, Carsten; Hohendorf, Stefan; Kolkoori, Sanjeevareddy; Wrobel, Norma; Nusser, Amélie; Freitag, Markus; Bücherl, Thomas; Bar, Doron; Mor, Ilan; Tamin, Noam; Weiss-Babai, Ruth; Bromberger, Benjamin; Dangendorf, Volker; Tittelmeier, Kai

    The objects of this investigation were sculptures taken from a ca. three hundred years old baroque epitaph of a church in Tönning, a town in Northern Germany. Around 1900 it was found in a disastrous state heavily damaged by wood-worm. At that time, the whole artwork was treated with the tar extract carbolineum as a remedy. Nowadays, this substance has been identified as carcinogenic, and its presence can be perceived by its stench and visually at certain spots on the surface where it has penetrated the covering paint. A gold-painted sculpture of a massive wooden skull was interrogated with X-rays and fast neutrons to investigate the internal distribution of the carbolineum. The X-ray tomography, with its excellent spatial resolution revealed galleries left over from the worm infestation in the outer areas and cracks in the central region. The golden color coating appeared as a thick and dense layer. In comparison the tomography with fast neutrons, though being of lower resolution and yet unresolved artefacts revealed sections of slightly different densities in the bulk of the wood. These differences we attribute to the differences in the distribution of the impregnant in the wood, visible due to its higher hydrogen content making it less transparent for neutrons.

  12. Radioactive Ion Beam Production by Fast-Neutron-Induced Fission in Actinide Targets at EURISOL

    CERN Document Server

    Herrera-Martínez, Adonai

    The European Isotope Separation On-Line Radioactive Ion Beam Facility (EURISOL) is set to be the 'next-generation' European Isotope Separation On-Line (ISOL) Radioactive Ion Beam (RIB) facility. It will extend and amplify current research on nuclear physics, nuclear astrophysics and fundamental interactions beyond the year 2010. In EURISOL, the production of high-intensity RIBs of specific neutron-rich isotopes is obtained by inducing fission in large-mass actinide targets. In our contribution, the use of uranium targets is shown to be advantageous to other materials, such as thorium. Therefore, in order to produce fissions in U-238 and reduce the plutonium inventory, a fast neutron energy spectrum is necessary. The large beam power required to achieve these RIB levels requires the use of a liquid proton-to-neutron converter. This article details the design parameters of the converter, with special attention to the coupled neutronics of the liquid converter and fission target. Calculations performed with the ...

  13. Multi-purpose fast neutron spectrum analyzer with real-time signal processing

    Energy Technology Data Exchange (ETDEWEB)

    Sulyaev, Yu.S., E-mail: sulyaev@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, 630090 Novosibirsk (Russian Federation); Puryga, E.A.; Khilchenko, A.D. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Kvashnin, A.N. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Polosatkin, S.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, 630090 Novosibirsk (Russian Federation); Rovenskikh, A.F. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Burdakov, A.V.; Grishnyaev, E.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation)

    2013-08-21

    Diagnostics of hot ion component of plasma on the products of fusion reactions is widely used on thermonuclear facilities. In case of employment of neutron spectrometers, based on organics scintillators, there is advanced technique developed to eliminate neutron pulses from gamma background—digital pulse shape discrimination. For every DPSD application it is necessary to use the fast (2–5 ns) and precise (12 bit) transient ADC unit with large amount of onboard memory for storing every digitized scintillation pulses during shot time. At present time the duration of hot thermonuclear plasma burning in large tokamaks approximate to 1 min, and this requires very high onboard memory capacity (∼100 GB). This paper describes a neutron spectrum analyzer with real-time DPSD algorithm, implemented to ADC unit. This approach saves about two orders of onboard memory capacity, gives the possibility of instant use of outcome to feedback systems. This analyzer was tested and calibrated with help of {sup 60}Co and {sup 252}Cf radiation sources, and deuterium neutron generator.

  14. Irradiation Effects for the Pulsed Fast Neutron Analysis (PFNA) Cargo Interrogation System

    Energy Technology Data Exchange (ETDEWEB)

    Slater, C.O.

    2001-02-02

    At the request of Safety and Ecology Corporation of Tennessee, radiation effects of the proposed Pulsed Fast Neutron Analysis (PFNA) Cargo Interrogation System have been examined. First, fissile cargo were examined to determine if a significant neutron signal would be observable during interrogation. Results indicated that ample multiplication would be seen for near critical bare targets. The water-reflected sphere showed relatively little multiplication. By implication, a fissile target shielded by hydrogenous cargo might not be detectable by neutron interrogation, particularly if reliance is placed on the neutron signal. The cargo may be detectable if use can be made of the ample increase in the photon signal. Second, dose rates were calculated at various locations within and just outside the facility building. These results showed that some dose rates may be higher than the target dose rate of 0.05 mrem/h. However, with limited exposure time, the total dose may be well below the allowed total dose. Lastly, estimates were made of the activation of structures and typical cargo. Most cargo will not be exposed long enough to be activated to levels of concern. On the other hand, portions of the structure may experience buildup of some radionuclides to levels of concern.

  15. Evaluation of fast neutron fluence for Kori Unit 2 pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Young Kyou; Lim, Mi Joung; Kim, Byoung Chul; Kim, Kyung Sik [Korea Reactor Integrity Surveillance Technology, Daejeon (Korea, Republic of)

    2011-10-15

    Unit 2 at Kori reactor has been put into operation in 1983. During 24 cycle operation, five surveillance capsules at inner vessel and three ex-vessel dosimeter at cavity both are taken out for evaluation to neutron fluence. The evaluations following the surveillance program of Kori 2 unit which are required detect and prevent degradation of safety-related structures and components of the vessel. The fast (E > 1.0 MeV) neutron fluencies are necessary to estimate the fracture toughness of the pressure vessel materials. The determination of the pressure vessel neutron fluence is based on both calculations and measurements. The fluence prediction is made with a calculation, and the measurements are used to qualify the calculational methodology. Measurement-to-calculation comparisons are used to identify biases in the calculations and to provide reliable estimates of the fluence uncertainties As shown in Fig. 1, the Kori unit 2 reactor vessel surveillance programs includes the analysis of flux dosimeters contained in capsules located on the inner vessel wall at the Beltline region (0., 15., 30. and 40. Azimuth) and Ex vessel dosimeter capsules located on the cavity at connected bid chain. In this paper, the methodologies used to perform neutron transport calculations and dosimetry evaluations are described, the results of the plant specific transport calculations are given for the beltline region of Kori Unit 2 pressure vessel and the comparisons of calculations and measurements are discussed

  16. Numerical study of point spread function of a fast neutron radiography system based on scintillating-fiber array

    Institute of Scientific and Technical Information of China (English)

    ZHANG; FaQiang

    2007-01-01

    For a scintillating-fiber array fast-neutron radiography system, a point-spread- function computing model was introduced, and the simulation code was developed. The results of calculation show that fast-neutron radiographs vary with the size of fast neutron sources, the size of fiber cross-section and the imaging geometry. The results suggest that the following qualifications are helpful for a good point spread function: The cross-section of scintillating fibers not greater than 200μm×200μm, the size of neutron source as small as a few millimeters, the distance between the source and the scintillating fiber array greater than 1 m, and inspected samples placed as close as possible to the array. The results give suggestions not only to experiment considerations but also to the estimation of spatial resolution for a specific system.……

  17. Numerical study of point spread function of a fast neutron radiography system based on scintillating-fiber array

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ For a scintillating-fiber array fast-neutron radiography system, a point-spread- function computing model was introduced, and the simulation code was developed. The results of calculation show that fast-neutron radiographs vary with the size of fast neutron sources, the size of fiber cross-section and the imaging geometry. The results suggest that the following qualifications are helpful for a good point spread function: The cross-section of scintillating fibers not greater than 200μm×200μm, the size of neutron source as small as a few millimeters, the distance between the source and the scintillating fiber array greater than 1 m, and inspected samples placed as close as possible to the array. The results give suggestions not only to experiment considerations but also to the estimation of spatial resolution for a specific system.

  18. Development of a neutron detector with broad dynamic range and multi-hit capability

    Science.gov (United States)

    Pawelczak, Iwona; Toke, Jan; Tsai, Yun-Tse; Udo Schröder, W.

    2007-10-01

    A new type of Gd-loaded plastic neutron detector with a broad dynamic range (from thermal to MeV range) and multi-hit capability has been designed and subjected to series of tests. The device consists of a stack of alternating plastic scintillator (Saint Gobain BC-408) slabs and thin radiator films (PDMS -- SYLGARD 184) loaded with 0.5% of Gd per weight, viewed by a photomultiplier tube. The scintillator functions as neutron moderator, provides a prompt integrated neutron energy signal, and detects delayed n capture by Gd nuclei via associated capture γ-rays. The design, Monte Carlo simulations carried out with an extended code DENIS(E), as well as first measurements with the detector will be discussed.

  19. Simulation of the response functions of an extended range neutron multisphere spectrometer using FLUKA

    Science.gov (United States)

    Wang, Pan-Feng; Ding, Ya-Dong; Wang, Qing-Bin; Ma, Zhong-Jian; Guo, Si-Ming; Li, Guan-Jia

    2015-07-01

    In this paper, the distribution of radiation field in the CSNS spectrometer hall at Dongguan, China, was simulated by the FLUKA program. The results show that the radiation field of the high energy proton accelerator is dominated by neutron radiation, with a broad range of neutron energies, spanning about eleven orders of magnitude. Simulation and calculation of the response functions of four Bonner spheres with a simplified model is done with FLUKA and MCNPX codes respectively, proving the feasibility of the FLUKA program for this application and the correctness of the calculation method. Using the actual model, we simulate and calculate the energy response functions of Bonner sphere detectors with polyethylene layers of different diameters, including detectors with lead layers, using the FLUKA code. Based on the simulation results, we select eleven detectors as the basic structure for an Extended Range Neutron Multisphere Spectrometer (ERNMS).

  20. Simulation of the response functions of an extended range neutron multisphere spectrometer using FLUKA

    Institute of Scientific and Technical Information of China (English)

    WANG Pan-Feng; DING Ya-Dong; WANG Qing-Bin; MA Zhong-Jian; GUO Si-Ming; LI Guan-Jia

    2015-01-01

    In this paper,the distribution of radiation field in the CSNS spectrometer hall at Dongguan,China,was simulated by the FLUKA program.The results show that the radiation field of the high energy proton accelerator is dominated by neutron radiation,with a broad range of neutron energies,spanning about eleven orders of magnitude.Simulation and calculation of the response functions of four Bonner spheres with a simplified model is done with FLUKA and MCNPX codes respectively,proving the feasibility of the FLUKA program for this application and the correctness of the calculation method.Using the actual model,we simulate and calculate the energy response functions of Bonner sphere detectors with polyethylene layers of different diameters,including detectors with lead layers,using the FLUKA code.Based on the simulation results,we select eleven detectors as the basic structure for an Extended Range Neutron Multisphere Spectrometer (ERNMS).

  1. Determination of the fast neutrons spectra by the Elastic scattering method (n, p); Determinacion del espectro de neutrones rapidos por el metodo de la dispersion elastica (n, p)

    Energy Technology Data Exchange (ETDEWEB)

    Elizalde D, J

    1973-07-01

    This work consists in determining the fast neutron spectra emitted by a Pu-Be isotopic source. The implemented technique is based in the spectrometry (n, p). This consists in making to fall on a fast neutrons beams (polyenergetic) over a thin film of hydrogenated material, detecting the spectra of emitted protons at a fix angle. The polyethylene film and the used solid state detector are inside of a vacuum chamber. The detector is placed at 30 degree with respect to direction of the incident neutrons beam. The protons spectra is stored in a multichannel. the energy is obtained with the prior calibration of the system. The data processing involves the transformation of the protons spectra observed at the falling on neutrons spectra over the film. The energy of the neutrons is related with that of the protons, according to the collision kinematical equations. The cross section of elastic collision of the neutrons with the hydrogen atoms is obtained from literature. Applying these relations to the observed spectra it is obtained the falling on neutron spectra over the film. (Author)

  2. A study on signal processing for wide-range neutron flux measurement using improved algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Jae Hong; Lee, Yeun Hee; Lee, Jeong Yang [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of)

    1996-03-01

    ENFMS(ex-core neutron flux monitoring system) is divided to source range, intermediate range and power ranger in accordance with its range and the output signal measurements of that are carried out with BF{sub 3} counter, fission chamber. There have been lots of study to adopt the wide-range measurement method which use only fission chamber through the whole reactor power. To do that is needs extending the power measurement range which is covered by fission chamber to lower power range. In lower power range the effect of noise in signal is greater relatively than that of high power range. The existing signal processing method to measurement plant power range in ENFMS in which the individual neutron flux pulse can be countered as the reactor power increased is MSV (mean square voltage) measurement. In this paper the extended method from MSV (2nd moment) mode to 3rd moment to improve the discrimination between neutron signal and background noise was studied. The simulation was shown that accuracy of power measurement in ENFMS using the method mention above would be improved. 2 tabs., 10 figs., 18 refs. (Author) .new.

  3. Magnetization studies of YBa 2Cu 3O 7-x irradiated by fast neutrons

    Science.gov (United States)

    Wisniewski, A.; Baran, M.; Przysłupski, P.; Szymczak, H.; Pajaczkowska, A.; Pytel, B.; Pytel, K.

    1988-02-01

    Studies of the effect of fast neutron damage on the magnetic hysteresis of YBa 2Cu 3O 7-x ceramic samples subjected to fluence of neutrons of 2∗10 16 n/cm 2 up to 6∗10 17 n/cm 2 have been performed. irradiation up to dose of 1∗10 17 did not cause any change in the critical temperature. However it causes a strong increase of the magnetic hysteresis which is presumably connected with the creation of defects. The critical current density at 77 K in H = 10 k0e for the sample irradiated with the dose 1∗10 17 n/cm 2 was estimated to be 520 A/cm 2 as compared to 29 A/cm 2 for the reference non-irradiated sample, non-irradiated sample.

  4. Statistical properties of an algorithm used for illicit substance detection by fast-neutron transmission

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.L.; Sagalovsky, L.; Micklich, B.J.; Harper, M.K.; Novick, A.H.

    1994-06-01

    A least-squares algorithm developed for analysis of fast-neutron transmission data resulting from non-destructive interrogation of sealed luggage and containers is subjected to a probabilistic interpretation. The approach is to convert knowledge of uncertainties in the derived areal elemental densities, as provided by this algorithm, into probability information that can be used to judge whether an interrogated object is either benign or potentially contains an illicit substance that should be investigated further. Two approaches are considered in this paper. One involves integration of a normalized probability density function associated with the least-squares solution. The other tests this solution against a hypothesis that the interrogated object indeed contains illicit material. This is accomplished by an application of the F-distribution from statistics. These two methods of data interpretation are applied to specific sets of neutron transmission results produced by Monte Carlo simulation.

  5. Nuclear data needs and sensitivities for illicit substance detection using fast-neutron transmission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Micklich, B.J.; Harper, M.K.; Sagalovsky, L.; Smith, D.L.

    1994-05-01

    Results from analysis of fast-neutron transmission spectra in the interrogation of luggage for illicit substances are quite sensitive to the neutron total cross section data employed. Monte Carlo and analytical techniques are used to explore the uses for such data and to demonstrate the sensitivity of these results to various total cross sections employed in the analysis. The status of total cross section information required for materials commonly found in containers having both illicit and benign substances, with particular attention to the matter of data uncertainties, is considered in the context of the available nuclear data. Deficiencies in the contemporary nuclear data base for this application are indicated and suggestions are offered for new measurements or evaluations.

  6. Study of the production of neutron-rich isotope beams issuing from fissions induced by fast neutrons; Etude de la production de faisceaux riches en neutrons par fission induite par neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Lau, Ch

    2000-09-15

    This work is a contribution to the PARRNe project (production of radioactive neutron-rich isotopes). This project is based on the fission fragments coming from the fission of 238-uranium induced by fast neutrons. The fast neutron flux is produced by the collisions of deutons in a converter. Thick targets of uranium carbide and liquid uranium targets have been designed in order to allow a quick release of fission fragments. A device, able to trap on a cryogenic thimble rare gas released by the target, has allowed the production of radioactive nuclei whose half-life is about 1 second. This installation has been settled to different deuton accelerators in the framework of the European collaboration SPIRAL-2. A calibration experiment has proved the feasibility of fixing an ISOL-type isotope separator to a 15 MV tandem accelerator, this installation can provide 500 nA deutons beams whose energy is 26 MeV and be a valuable tool for studying fast-neutron induced fission. Zinc, krypton, rubidium, cadmium, iodine, xenon and cesium beams have been produced in this installation. The most intense beams reach 10000 nuclei by micro-coulomb for 26 MeV deutons. An extra gain of 2 magnitude orders can be obtained by using a more specific ion source and by increasing the thickness of the target. Another extra gain of 2 magnitude orders involves 100 MeV deutons.

  7. MCNP Simulations of Measurement of Insulation Compaction in the Cryogenic Rocket Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

    Science.gov (United States)

    Livingston, R. A.; Schweitzer, J. S.; Parsons, A. M.; Arens, E. E.

    2010-01-01

    MCNP simulations have been run to evaluate the feasibility of using a combination of fast and thermal neutrons as a nondestructive method to measure of the compaction of the perlite insulation in the liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC). Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. When heated it expands from four to twenty times its original volume which makes it very useful for thermal insulation. The cryogenic tanks at Kennedy Space Center are spherical with outer diameters of 69-70 feet and lined with a layer of expanded perlite with thicknesses on the order of 120 cm. There is evidence that some of the perlite has compacted over time since the tanks were built 1965, affecting the thermal properties and possibly also the structural integrity of the tanks. With commercially available portable neutron generators it is possible to produce simultaneously fluxes of neutrons in two energy ranges: fast (14 Me V) and thermal (25 me V). The two energy ranges produce complementary information. Fast neutrons produce gamma rays by inelastic scattering, which is sensitive to Fe and O. Thermal neutrons produce gamma rays by prompt gamma neutron activation (PGNA) and this is sensitive to Si, Al, Na, K and H. The compaction of the perlite can be measured by the change in gamma ray signal strength which is proportional to the atomic number densities of the constituent elements. The MCNP simulations were made to determine the magnitude of this change. The tank wall was approximated by a I-dimensional slab geometry with an 11/16" outer carbon steel wall, an inner stainless wall and 120 cm thick perlite zone. Runs were made for cases with expanded perlite, compacted perlite or with various void fractions. Runs were also made to simulate the effect of adding a moderator. Tallies were made for decay-time analysis from t=0 to 10 ms; total detected gamma

  8. Contributions to the neutronic analysis of a gas-cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Martin-del-Campo, Cecilia, E-mail: cecilia.martin.del.campo@gmail.com [Departamento de Sistemas Energeticos, Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Paseo Cuauhnahuac 8532. Jiutepec, Morelos (Mexico); Reyes-Ramirez, Ricardo, E-mail: ricarera@yahoo.com.mx [Departamento de Sistemas Energeticos, Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Paseo Cuauhnahuac 8532. Jiutepec, Morelos (Mexico); Francois, Juan-Luis, E-mail: juan.luis.francois@gmail.com [Departamento de Sistemas Energeticos, Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Paseo Cuauhnahuac 8532. Jiutepec, Morelos (Mexico); Reinking-Cejudo, Arturo G., E-mail: reinking@servidor.unam.mx [Departamento de Sistemas Energeticos, Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Paseo Cuauhnahuac 8532. Jiutepec, Morelos (Mexico)

    2011-06-15

    Highlights: > Differences on reactivity with MCNPX and TRIPOLI-4 are negligible. > Fuel lattice and core criticality calculations were done. > A higher Doppler coefficient than coolant density coefficient. > Zirconium carbide is a better reflector than silicon carbide. > Adequate active height, radial size and reflector thickness were obtained. - Abstract: In this work the Monte Carlo codes MCNPX and TRIPOLI-4 were used to perform the criticality calculations of the fuel assembly and the core configuration of a gas-cooled fast reactor (GFR) concept, currently in development. The objective is to make contributions to the neutronic analysis of a gas-cooled fast reactor. In this study the fuel assembly is based on a hexagonal lattice of fuel-pins. The materials used are uranium and plutonium carbide as fuel, silicon carbide as cladding, and helium gas as coolant. Criticality calculations were done for a fuel assembly where the axial reflector thickness was varied in order to find the optimal thickness. In order to determine the best material to be used as a reflector, in the reactor core with neutrons of high energy spectrum, criticality calculations were done for three reflector materials: zirconium carbide, silicon carbide and natural uranium. It was found that the zirconium carbide provides the best neutron reflection. Criticality calculations using different active heights were done to determine the optimal height, and the reflector thickness was adjusted. Core criticality calculations were performed with different radius sizes to determine the active radial dimension of the core. A negative temperature coefficient of reactivity was verified for the fuel. The effect on reactivity produced by changes in the coolant density was also evaluated. We present the main neutronic characteristics of a preliminary fuel and core designs for the GFR concept. ENDF-VI cross-sections libraries were used in both the MCNPX and TRIPOLI-4 codes, and we verified that the obtained

  9. NEUTRON CROSS SECTION EVALUATIONS OF FISSION PRODUCTS BELOW THE FAST ENERGY REGION

    Energy Technology Data Exchange (ETDEWEB)

    OH,S.Y.; CHANG,J.; MUGHABGHAB,S.

    2000-05-11

    Neutron cross section evaluations of the fission-product isotopes, {sup 95}Mo, {sup 99}Tc, {sup 101}Ru, {sup 103}Rh, {sup 105}Pd, {sup 109}Ag, {sup 131}Xe, {sup 133}Cs, {sup 141}Pr, {sup 141}Nd, {sup 147}Sm, {sup 149}Sm, {sup 150}Sm, {sup 151}Sm, {sup 152}Sm, {sup 153}Eu, {sup 155}Gd, and {sup 157}Gd were carried out below the fast neutron energy region within the framework of the BNL-KAERI international collaboration. In the thermal energy region, the energy dependence of the various cross-sections was calculated by applying the multi-level Breit-Wigner formalism. In particular, the strong energy dependence of the coherent scattering lengths of {sup 155}Gd and {sup 157}Gd were determined and were compared with recent calculations of Lynn and Seeger. In the resonance region, the recommended resonance parameters, reported in the BNL compilation, were updated by considering resonance parameter information published in the literature since 1981. The s-wave and, if available, p-wave reduced neutron widths were analyzed in terms of the Porter-Thomas distribution to determine the average level spacings and the neutron strength functions. Average radiative widths were also calculated from measured values of resolved energy resonances. The average resonance parameters determined in this study were compared with those in the BNL and other compilations, as well as the ENDF/B-VI, JEF-2.2, and JENDL-3.2 data libraries. The unresolved capture cross sections of these isotopes, computed with the determined average resonance parameters, were compared with measurements, as well as the ENDF/B-VI evaluations. To achieve agreement with the measurements, in a few cases minor adjustments in the average resonance parameters were made. Because of astrophysical interest, the Maxwellian capture cross sections of these nuclides at a neutron temperature of 30 keV were computed and were compared with other compilations and evaluations.

  10. Characterizing a fast-response, low-afterglow liquid scintillator for neutron time-of-flight diagnostics in fast ignition experiments

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Y., E-mail: abe-y@ile.osaka-u.ac.jp; Hosoda, H.; Arikawa, Y.; Nagai, T.; Kojima, S.; Sakata, S.; Inoue, H.; Iwasa, Y.; Iwano, K.; Yamanoi, K.; Fujioka, S.; Nakai, M.; Sarukura, N.; Shiraga, H.; Norimatsu, T.; Azechi, H. [Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2014-11-15

    The characteristics of oxygen-enriched liquid scintillators with very low afterglow are investigated and optimized for application to a single-hit neutron spectrometer for fast ignition experiments. It is found that 1,2,4-trimethylbenzene has better characteristics as a liquid scintillator solvent than the conventional solvent, p-xylene. In addition, a benzophenon-doped BBQ liquid scintillator is shown to demonstrate very rapid time response, and therefore has potential for further use in neutron diagnostics with fast time resolution.

  11. N-acetylcysteine and captopril protect DNA and cells against radiolysis by fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Spotheim-Maurizot, M. (CNRS, 45 - Orleans (France). Centre de Biophysique Moleculaire); Garnier, F. (CNRS, 45 - Orleans (France). Centre de Biophysique Moleculaire); Kieda, C. (CNRS, 45 - Orleans (France). Centre de Biophysique Moleculaire); Sabattier, R. (Centre Hospitalier Regional d' Orleans, 45 (France). Service de Radiotherapie); Charlier, M. (CNRS, 45 - Orleans (France). Centre de Biophysique Moleculaire)

    1993-10-01

    N-Acetylcysteine and captopril, respectively mucolytic and antihypertensive drugs, contain free sulfhydryl groups. Since in general thiols have well-established radioprotective abilities, we sought putative radioprotective effects of these drugs against therapeutic fast neutrons. We show that pBR322 plasmid DNA is indeed protected against radiolytic strand breakage by both drugs. The oxygen independent protection is consistent with a hydroxyl radical scavenging mechanism. A clonogenicity assay reveals an increase of the survival of SCL-1 cultured keratinocytes irradiated in the presence of the drugs compared with cells irradiated without drugs. Our results suggest possible interferences between treatment with drugs bearing-SH groups and radiotherapy. (orig.)

  12. Defects in Fast-Neutron Irradiated Nitrogen-Doped Czochralski Silicon after Annealing at High Temperature

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Fast-neutron irradiated nitrogen-doped Czochralski silicon (NCZ-Si) was annealed at 1100 ℃ for different time, then FTIR and optical microscope were used to study the behavior of oxygen. It is found that [Oi] increase at the early stage then decrease along with the increasing of anneal time. High density induced-defects can be found in the cleavage plane. By comparing NCZ-Si with Czochralski silicon (CZ-Si), [Oi] in NCZ-Si decrease more after anneal 24 h.

  13. A portable and wide energy range semiconductor-based neutron spectrometer

    Science.gov (United States)

    Hoshor, C. B.; Oakes, T. M.; Myers, E. R.; Rogers, B. J.; Currie, J. E.; Young, S. M.; Crow, J. A.; Scott, P. R.; Miller, W. H.; Bellinger, S. L.; Sobering, T. J.; Fronk, R. G.; Shultis, J. K.; McGregor, D. S.; Caruso, A. N.

    2015-12-01

    Hand-held instruments that can be used to passively detect and identify sources of neutron radiation-either bare or obscured by neutron moderating and/or absorbing material(s)-in real time are of interest in a variety of nuclear non-proliferation and health physics applications. Such an instrument must provide a means to high intrinsic detection efficiency and energy-sensitive measurements of free neutron fields, for neutrons ranging from thermal energies to the top end of the evaporation spectrum. To address and overcome the challenges inherent to the aforementioned applications, four solid-state moderating-type neutron spectrometers of varying cost, weight, and complexity have been designed, fabricated, and tested. The motivation of this work is to introduce these novel human-portable instruments by discussing the fundamental theory of their operation, investigating and analyzing the principal considerations for optimal instrument design, and evaluating the capability of each of the four fabricated spectrometers to meet the application needs.

  14. A portable and wide energy range semiconductor-based neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hoshor, C.B. [Department of Physics, University of Missouri, Kansas City, MO (United States); Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Myers, E.R.; Rogers, B.J.; Currie, J.E.; Young, S.M.; Crow, J.A.; Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, Manhattan, KS (United States); Fronk, R.G.; Shultis, J.K.; McGregor, D.S. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2015-12-11

    Hand-held instruments that can be used to passively detect and identify sources of neutron radiation—either bare or obscured by neutron moderating and/or absorbing material(s)—in real time are of interest in a variety of nuclear non-proliferation and health physics applications. Such an instrument must provide a means to high intrinsic detection efficiency and energy-sensitive measurements of free neutron fields, for neutrons ranging from thermal energies to the top end of the evaporation spectrum. To address and overcome the challenges inherent to the aforementioned applications, four solid-state moderating-type neutron spectrometers of varying cost, weight, and complexity have been designed, fabricated, and tested. The motivation of this work is to introduce these novel human-portable instruments by discussing the fundamental theory of their operation, investigating and analyzing the principal considerations for optimal instrument design, and evaluating the capability of each of the four fabricated spectrometers to meet the application needs.

  15. Modeling the radiolysis of supercritical water by fast neutrons: density dependence of the yields of primary species at 400°c.

    Science.gov (United States)

    Butarbutar, Sofia Loren; Meesungnoen, Jintana; Guzonas, David A; Stuart, Craig R; Jay-Gerin, Jean-Paul

    2014-12-01

    A reliable understanding of radiolysis processes in supercritical water (SCW)-cooled reactors is crucial to developing chemistry control strategies that minimize the corrosion and degradation of materials. However, directly measuring the chemistry in reactor cores is difficult due to the extreme conditions of high temperature and pressure and mixed neutron and gamma-radiation fields, which are incompatible with normal chemical instrumentation. Thus, chemical models and computer simulations are an important route of investigation for predicting the detailed radiation chemistry of the coolant in a SCW reactor and the consequences for materials. Surprisingly, information on the fast neutron radiolysis of water at high temperatures is limited, and even more so for fast neutron irradiation of SCW. In this work, Monte Carlo simulations were used to predict the G values for the primary species e(-)aq, H(•), H2, (•)OH and H2O2 formed from the radiolysis of pure, deaerated SCW (H2O) by 2 MeV monoenergetic neutrons at 400°C as a function of water density in the range of ∼0.15-0.6 g/cm(3). The 2 MeV neutron was taken as representative of a fast neutron flux in a reactor. For light water, the moderation of these neutrons after knock-on collisions with water molecules generated mostly recoil protons of 1.264, 0.465, 0.171 and 0.063 MeV. Neglecting oxygen ion recoils and assuming that the most significant contribution to the radiolysis came from these first four recoil protons, the fast neutron yields were estimated as the sum of the G values for these protons after appropriate weightings were applied according to their energy. Calculated yields were compared with available experimental data and with data obtained for low-LET radiation. Most interestingly, the reaction of H(•) atoms with water was found to play a critical role in the formation yields of H2 and (•)OH at 400°C. Recent work has underscored the potential importance of this reaction above 200°C, but its

  16. Field test and evaluation of the passive neutron coincidence collar for prototype fast reactor fuel subassemblies

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, H.O.; Keddar, A.

    1982-08-01

    The passive neutron Coincidence Collar, which was developed for the verification of plutonium content in fast reactor fuel subassemblies, has been field tested using Prototype Fast Reactor fuel. For passive applications, the system measures the /sup 240/Pu-effective mass from the spontaneous fission rate, and in addition, a self-interrogation technique is used to determine the fissile content in the subassembly. Both the passive and active modes were evaluated at the Windscale Works in the United Kingdom. The results of the tests gave a standard deviation 0.75% for the passive count and 3 to 7% for the active measurement for a 1000-s counting time. The unit will be used in the future for the verification of plutonium in fresh fuel assemblies.

  17. Detection of special nuclear material by observation of delayed neutrons with a novel fast neutron composite detector

    Science.gov (United States)

    Mayer, Michael; Nattress, Jason; Barhoumi Meddeb, Amira; Foster, Albert; Trivelpiece, Cory; Rose, Paul; Erickson, Anna; Ounaies, Zoubeida; Jovanovic, Igor

    2015-10-01

    Detection of shielded special nuclear material is crucial to countering nuclear terrorism and proliferation, but its detection is challenging. By observing the emission of delayed neutrons, which is a unique signature of nuclear fission, the presence of nuclear material can be inferred. We report on the observation of delayed neutrons from natural uranium by using monoenergetic photons and neutrons to induce fission. An interrogating beam of 4.4 MeV and 15.1 MeV gamma-rays and neutrons was produced using the 11B(d,n-γ)12C reaction and used to probe different targets. Neutron detectors with complementary Cherenkov detectors then discriminate material undergoing fission. A Li-doped glass-polymer composite neutron detector was used, which displays excellent n/ γ discrimination even at low energies, to observe delayed neutrons from uranium fission. Delayed neutrons have relatively low energies (~0.5 MeV) compared to prompt neutrons, which makes them difficult to detect using recoil-based detectors. Neutrons were counted and timed after the beam was turned off to observe the characteristic decaying time profile of delayed neutrons. The expected decay of neutron emission rate is in agreement with the common parametrization into six delayed neutron groups.

  18. Commissioning of the IDS Neutron Detector and $\\beta$-decay fast-timing studies at IDS

    CERN Document Server

    Piersa, Monika

    2016-01-01

    The following report describes my scientific activities performed during the Summer Student Programme at ISOLDE. The main part of my project was focused on commissioning the neutron detector dedicated to nuclear decay studies at ISOLDE Decay Station (IDS). I have participated in all the steps needed to make it operational for the IS609 experiment. In the testing phase, we obtained expected detector response and calibrations confirmed its successful commissioning. The detector was mounted in the desired geometry at IDS and used in measurements of the beta-delayed neutron emission of $^8$He. After completing aforementioned part of my project, I became familiar with the fast-timing method. This technique was applied at IDS in the IS610 experiment performed in June 2016 to explore the structure of neutron-rich $^{130-134}$Sn nuclei. Since the main part of my PhD studies will be the analysis of data collected in this experiment, the second part of my project was dedicated to acquiring knowledge about technical de...

  19. Neutron yield when fast deuterium ions collide with strongly charged tritium-saturated dust particles

    Energy Technology Data Exchange (ETDEWEB)

    Akishev, Yu. S., E-mail: akishev@triniti.ru; Karal’nik, V. B.; Petryakov, A. V.; Starostin, A. N.; Trushkin, N. I.; Filippov, A. V. [State Research Center of Russian Federation, Troitsk Institute for Innovation and Thermonuclear Research (Russian Federation)

    2017-02-15

    The ultrahigh charging of dust particles in a plasma under exposure to an electron beam with an energy up to 25 keV and the formation of a flux of fast ions coming from the plasma and accelerating in the strong field of negatively charged particles are considered. Particles containing tritium or deuterium atoms are considered as targets. The calculated rates of thermonuclear fusion reactions in strongly charged particles under exposure to accelerated plasma ions are presented. The neutron generation rate in reactions with accelerated deuterium and tritium ions has been calculated for these targets. The neutron yield has been calculated when varying the plasma-forming gas pressure, the plasma density, the target diameter, and the beam electron current density. Deuterium and tritium-containing particles are shown to be the most promising plasmaforming gas–target material pair for the creation of a compact gas-discharge neutron source based on the ultrahigh charging of dust particles by beam electrons with an energy up to 25 keV.

  20. Feasibility of fast neutron analysis for the detection of explosives buried in soil

    Energy Technology Data Exchange (ETDEWEB)

    Faust, A.A. [Defence R and D Canada - Suffield, Medicine Hat, Alta. (Canada); McFee, J.E., E-mail: John.McFee@drdc-rddc.gc.ca [Defence R and D Canada - Suffield, Medicine Hat, Alta. (Canada); Bowman, C.L.; Mosquera, C. [Defence R and D Canada - Suffield, Medicine Hat, Alta. (Canada); Andrews, H.R.; Kovaltchouk, V.D.; Ing, H. [Bubble Technology Industries, Chalk River, Ont. (Canada)

    2011-12-11

    A commercialized thermal neutron analysis (TNA) sensor has been developed to confirm the presence of buried bulk explosives as part of a multi-sensor anti-tank landmine detection system. Continuing improvements to the TNA system have included the use of an electronic pulsed neutron generator that offers the possibility of applying fast neutron analysis (FNA) methods to improve the system's detection capability. This paper describes an investigation into the use of FNA as a complementary component in such a TNA system. The results of a modeling study using simple geometries and a full model of the TNA sensor head are presented, as well as preliminary results from an experimental associated particle imaging (API) system that supports the modeling study results. The investigation has concluded that the pulsed beam FNA approach would not improve the detection performance of a TNA system for landmine or buried IED detection in a confirmation role, and could not be made into a practical stand-alone detection system for buried anti-tank landmines. Detection of buried landmines and IEDs by FNA remains a possibility, however, through the use of the API technique.

  1. Estimates for Pu-239 loadings in burial ground culverts based on fast/slow neutron measurements

    Energy Technology Data Exchange (ETDEWEB)

    Winn, W.G.; Hochel, R.C.; Hofstetter, K.J.; Sigg, R.A.

    1989-08-15

    This report provides guideline estimates for Pu-239 mass loadings in selected burial ground culverts. The relatively high recorded Pu-239 contents of these culverts have been appraised as suspect relative to criticality concerns, because they were assayed only with the solid waste monitor (SWM) per gamma-ray counting. After 1985, subsequent waste was also assayed with the neutron coincidence counter (NCC), and a comparison of the assay methods showed that the NCC generally yielded higher assays than the SWM. These higher NCC readings signaled a need to conduct non-destructive/non-intrusive nuclear interrogations of these culverts, and a technical team conducted scoping measurements to illustrate potential assay methods based on neutron and/or gamma counting. A fast/slow neutron method has been developed to estimate the Pu-239 in the culverts. In addition, loading records include the SWM assays of all Pu-239 cuts of some of the culvert drums and these data are useful in estimating the corresponding NCC drum assays from NCC vs SWM data. Together, these methods yield predictions based on direct measurements and statistical inference.

  2. Studies of medium-range correlations by small-/wide-angle neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Otomo, Toshiya; Kamiyama, Takashi; Furusaka, Michihiro [Institute of Material Structure Science Lab., Neutron Science Lab., Tsukuba, Ibaraki (Japan); Kanno, Ryoji [Tokyo Institute of Technology, Dept. of Electronic Chemistry, Yokohama, Kanagawa (Japan); Yamamuro, Osamu [Osaka Univ., Graduate School of Science, Dept. of Chemistry and Microcalorimetry Research Center, Toyonaka, Osaka (Japan)

    2002-01-01

    A small/wide-angle neutron diffractometers (SWAN) covers very wide Q-range, 0.007A{sup -1} to 12A{sup -1}, therefore this instrument is useful to investigate medium-range correlations in many materials, including biological materials. Two examples are here to show the usefulness of the wide Q-range measurements to understand Li-absorption mechanism in hard-carbon as a battery anode material and to investigate medium-range correlation in vapor deposited CCl{sub 4} glass system. (author)

  3. Universality in the neutron$-^{19}$C scattering using finite range separable interactions

    CERN Document Server

    Shalchi, M A; Hadizadeh, M R; Frederico, T; Tomio, Lauro

    2016-01-01

    We report a study on the low-energy properties of the elastic $s-$wave scattering of a neutron ($n$) in the carbon isotope $^{19}$C near the critical condition for the occurrence of an excited Efimov state in the three-body $n-n-^{18}$C system. For the separation energy of the two halo neutrons in $^{20}$C we use the available experimental data. We also investigate to which extent the universal scaling laws, strictly valid in the zero-range limit, will survive when using finite-range interactions. By allowing to vary the $n-^{18}$C binding energy, a scaling behavior for the real and imaginary parts of the $s-$wave phase-shift $\\delta_0$ is verified, emerging some universal characteristics given by the pole-position of $k\\cot(\\delta_0^R)$ and effective-range parameters.

  4. Calculations of the thermal and fast neutron fluxes in the Syrian miniature neutron source reactor using the MCNP-4C code.

    Science.gov (United States)

    Khattab, K; Sulieman, I

    2009-04-01

    The MCNP-4C code, based on the probabilistic approach, was used to model the 3D configuration of the core of the Syrian miniature neutron source reactor (MNSR). The continuous energy neutron cross sections from the ENDF/B-VI library were used to calculate the thermal and fast neutron fluxes in the inner and outer irradiation sites of MNSR. The thermal fluxes in the MNSR inner irradiation sites were also measured experimentally by the multiple foil activation method ((197)Au (n, gamma) (198)Au and (59)Co (n, gamma) (60)Co). The foils were irradiated simultaneously in each of the five MNSR inner irradiation sites to measure the thermal neutron flux and the epithermal index in each site. The calculated and measured results agree well.

  5. Simulation and prototyping of 2 m long resistive plate chambers for detection of fast neutrons and multi-neutron event identification

    Energy Technology Data Exchange (ETDEWEB)

    Elekes, Z., E-mail: z.elekes@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Aumann, T. [GSI Helmholtzzentrumfür Schwerionenforschung, Darmstadt (Germany); Technische Universität Darmstadt, Darmstadt (Germany); Bemmerer, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Boretzky, K. [GSI Helmholtzzentrumfür Schwerionenforschung, Darmstadt (Germany); Caesar, C. [GSI Helmholtzzentrumfür Schwerionenforschung, Darmstadt (Germany); Technische Universität Darmstadt, Darmstadt (Germany); Cowan, T.C. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universität Dresden, Dresden (Germany); Hehner, J.; Heil, M. [GSI Helmholtzzentrumfür Schwerionenforschung, Darmstadt (Germany); Kempe, M. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Rossi, D. [GSI Helmholtzzentrumfür Schwerionenforschung, Darmstadt (Germany); Röder, M. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universität Dresden, Dresden (Germany); Simon, H. [GSI Helmholtzzentrumfür Schwerionenforschung, Darmstadt (Germany); Sobiella, M.; Stach, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Reinhardt, T. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universität Dresden, Dresden (Germany); Wagner, A.; Yakorev, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Zilges, A. [Universität zu Köln, Köln (Germany); Zuber, K. [Technische Universität Dresden, Dresden (Germany)

    2013-02-11

    Resistive plate chamber (RPC) prototypes of 2 m length were simulated and built. The experimental tests using a 31 MeV electron beam, discussed in details, showed an efficiency higher than 90% and an excellent time resolution of around σ=100ps. Furthermore, comprehensive simulations were performed by GEANT4 toolkit in order to study the possible use of these RPCs for fast neutron (200 MeV–1 GeV) detection and multi-neutron event identification. The validation of simulation parameters was carried out via a comparison to experimental data. A possible setup for invariant mass spectroscopy of multi-neutron emission is presented and the characteristics are discussed. The results show that the setup has a high detection efficiency. Its capability of determining the momentum of the outgoing neutrons and reconstructing the relative energy between the fragments from nuclear reactions is demonstrated for different scenarios.

  6. Application of fast neutron radiography to three-dimensional visualization of steady two-phase flow in a rod bundle

    CERN Document Server

    Takenaka, N; Fujii, T; Mizubata, M; Yoshii, K

    1999-01-01

    Three-dimensional void fraction distribution of air-water two-phase flow in a 4x4 rod-bundle near a spacer was visualized by fast neutron radiography using a CT method. One-dimensional cross sectional averaged void fraction distribution was also calculated. The behaviors of low void fraction (thick water) two-phase flow in the rod bundle around the spacer were clearly visualized. It was shown that the void fraction distributions were visualized with a quality similar to those by thermal neutron radiography for low void fraction two-phase flow which is difficult to visualize by thermal neutron radiography. It is concluded that the fast neutron radiography is efficiently applicable to two-phase flow studies.

  7. Neutronic and thermal analysis of composite fuel for potential deployment in fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Abou Jaoude, Abdalla; Thomas, Colin; Erickson, Anna, E-mail: erickson@gatech.edu

    2016-07-15

    Highlights: • Neutronic and heat transfer performance of composite fuels on the macro-scale. • Methodology to guide flexible fuel design using high fidelity simulation tools. • Viability of composite fuels for ultra-high burnup fast reactor deployment. - Abstract: Composite fuels are promising candidates for high-burnup fast reactors because of their accommodation of swelling, limited fuel-cladding interactions and flexibility in design. While a proof-of-concept fuel consisting of granules of U-alloys and PuO{sub 2} dispersed within a porous zirconium matrix was successfully manufactured and irradiated, its neutronic and thermal performance remains to be optimized as compared to currently utilized fuels. MCNP6, COMSOL and a sphere packing algorithm were employed to perform the analysis. We found that both the theoretical maximum burnup reached and the temperature profiles are comparable to that of the currently considered alternative fuel. The results are promising and do not indicate any substantial limitation to the deployment of composite fuel. The fuel type merits further research, including full-core simulations. The methodology followed herein also provides a basis for screening different material compositions and guiding materials selection in composite fuels.

  8. High energy fast neutrons from the Harwell variable energy cyclotron. I. Physical characteristics.

    Science.gov (United States)

    Goodhead, D T; Berry, R J; Bance, D A; Gray, P; Stedeford, J B

    1977-10-01

    A high energy fast neutron beam potentially suitable for radiotherapy was built at the Harwell variable energy cyclotron. The beam line is described and results are given of physical measurements on the fast neutron beams produced by 42 MeV deuterons on thick (4 mm) and thin (2 mm) beryllium targets. With 20 muA beam current the entrance dose rate in a phantom 150 cm from the target was about 130 rad min-1 with the thick target and about 60 rad min-1 with the thin target. Therefore, it is possible to use both the thin target and the relatively large target-skin distance of 150 cm to improve depth dose for radiotherapy or radiobiology. With this arrangement the dose rate decreased to 50% at depths in the phantom of 11.3-15.4 cm, depending on the field size. The use of primarily hydrogenous materials for shielding and collimation provided beam edge definition similar to that of 60Co teletherapy units, and off-axis radiation levels of approximately 1% which compare favorably with 14 MeV deuteron-tritium generators. The copper backing of the thin target became highly radioactive and an alterative material may be preferable. Biologic characteristics of the beam are described in a companion paper.

  9. Determination of radionuclides induced by fast neutrons from the JCO criticality accident in Tokai-mura, Japan for estimating neutron doses.

    Science.gov (United States)

    Kojima, S; Imanaka, T; Takada, J; Mitsugashira, T; Nakanishi, T; Seki, R; Kondo, M; Sasaki, K I; Saito, T; Yamaguchi, Y; Furukawa, M

    2001-09-01

    A criticality accident occurred at a uranium conversion facility in Tokai-mura, Japan on September 30, 1999, and fission neutrons were continuously emitted for about 20 hours. Materials of stainless steel or iron, and chemical reagents were collected at places between 2 m and 270 m from the criticality accident site on October 25 and 26, 1999, November 27, 1999 and February 11, 2000. Neutron-induced radionuclides. such as 54Mn and 58Co, in the materials exposed to fast neutrons from the accident were measured to estimate the neutron fluences and energy distributions. Highly sensitive y-ray spectrometry with a well-type Ge detector was performed after radiochemical separation of Mn and Co from the materials. An instrumental neutron activation analysis was mainly applied for determinations of the target elements and chemical yields. The concentrations of 54Mn and 58Co in a mesh screen of stainless steel collected at a location 2.0 m from the accident site were determined. The total number of fission events was evaluated to be 2.5 x 10(18) by Monte-Carlo calculations of neutron transfer by considering the observed values of 54Mn and 58Co. The results presented here are fundamental to estimate the neutron doses at various distances.

  10. Gram-scale Plutonium Samples Measured by Experimental Device of Four Detectors Well-type Fast Neutron Coincidence Measurement

    Institute of Scientific and Technical Information of China (English)

    LIU; Guo-rong; LIANG; Qing-lei; LI; Jing-huai; LI; An-li

    2013-01-01

    Experimental device of four detectors well-type fast neutron coincidence measurement(see Fig.1)consists of four?127 mm×50.8 mm BC501A liquid scintillation detectors,DC271A digitizer and other circuits.Application program simultaneously acquires the waveform of each pulse output from each detector,and identifies each pulse from neutron or?particle by offline model,and gets their arrival timing.

  11. MCNP5 and GEANT4 comparisons for preliminary Fast Neutron Pencil Beam design at the University of Utah TRIGA system

    Science.gov (United States)

    Adjei, Christian Amevi

    The main objective of this thesis is twofold. The starting objective was to develop a model for meaningful benchmarking of different versions of GEANT4 against an experimental set-up and MCNP5 pertaining to photon transport and interactions. The following objective was to develop a preliminary design of a Fast Neutron Pencil Beam (FNPB) Facility to be applicable for the University of Utah research reactor (UUTR) using MCNP5 and GEANT4. The three various GEANT4 code versions, GEANT4.9.4, GEANT4.9.3, and GEANT4.9.2, were compared to MCNP5 and the experimental measurements of gamma attenuation in air. The average gamma dose rate was measured in the laboratory experiment at various distances from a shielded cesium source using a Ludlum model 19 portable NaI detector. As it was expected, the gamma dose rate decreased with distance. All three GEANT4 code versions agreed well with both the experimental data and the MCNP5 simulation. Additionally, a simple GEANT4 and MCNP5 model was developed to compare the code agreements for neutron interactions in various materials. Preliminary FNPB design was developed using MCNP5; a semi-accurate model was developed using GEANT4 (because GEANT4 does not support the reactor physics modeling, the reactor was represented as a surface neutron source, thus a semi-accurate model). Based on the MCNP5 model, the fast neutron flux in a sample holder of the FNPB is obtained to be 6.52×107 n/cm2s, which is one order of magnitude lower than gigantic fast neutron pencil beam facilities existing elsewhere. The MCNP5 model-based neutron spectrum indicates that the maximum expected fast neutron flux is at a neutron energy of ~1 MeV. In addition, the MCNP5 model provided information on gamma flux to be expected in this preliminary FNPB design; specifically, in the sample holder, the gamma flux is to be expected to be around 108 γ/cm 2s, delivering a gamma dose of 4.54×103 rem/hr. This value is one to two orders of magnitudes below the gamma

  12. Monte Carlo MSM correction factors for control rod worth estimates in subcritical and near-critical fast neutron reactors

    Directory of Open Access Journals (Sweden)

    Lecouey Jean-Luc

    2015-01-01

    Full Text Available The GUINEVERE project was launched in 2006, within the 6th Euratom Framework Program IP-EUROTRANS, in order to study the feasibility of transmutation in Accelerator Driven subcritical Systems (ADS. This zero-power facility hosted at the SCK·CEN site in Mol (Belgium couples the fast subcritical lead reactor VENUS-F with an external neutron source provided by interaction of deuterons delivered by the GENEPI-3C accelerator and a tritiated target located at the reactor core center. In order to test on-line subcriticality monitoring techniques, the reactivity of all the VENUS-F configurations used must be known beforehand to serve as benchmark values. That is why the Modified Source Multiplication Method (MSM is under consideration to estimate the reactivity worth of the control rods when the reactor is largely subcritical as well as near-critical. The MSM method appears to be a technique well adapted to measure control rod worth over a large range of subcriticality levels. The MSM factors which are required to account for spatial effects in the reactor can be successfully calculated using a Monte Carlo neutron transport code.

  13. Evaluation of Silicon Neutron Resonance Parameters in the Energy Range Thermal to 1800 keV

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H.

    2002-09-30

    The evaluation of the neutron cross sections of the three stable isotopes of silicon in the energy range thermal to 20 MeV was performed by Hetrick et al. for ENDF/B-VI (Evaluated Nuclear Data File). Resonance parameters were obtained in the energy range thermal to 1500 keV from a SAMMY analysis of the Oak Ridge National Laboratory experimental neutron transmission data. A new measurement of the capture cross section of natural silicon in the energy range 1 to 700 keV has recently been performed at the Oak Ridge Electron Linear Accelerator. Results of this measurement were used in a SAMMY reevaluation of the resonance parameters, allowing determination of the capture width of a large number of resonances. The experimental data base is described; properties of the resonance parameters are given. For the first time the direct neutron capture component has been taken into account from the calculation by Rauscher et al. in the energy range from thermal to 1 MeV. Results of benchmark calculations are also given. The new evaluation is available in the ENDF/B-VI format.

  14. Development of time-of-flight neutron detector with fast-decay and low-afterglow scintillator for fast ignition experiment

    Directory of Open Access Journals (Sweden)

    Nagai T.

    2013-11-01

    Full Text Available A fast-decay and low-afterglow liquid scintillator was developed for the fast ignition experiment at the Institute of Laser Engineering (ILE. The liquid scintillator was coupled to a gated photomultiplier (PMT, and the gating performance under high-intensity γ-rays was experimentally checked. In 2010, a detector with a high detection efficiency of 10−4 was developed and installed in this experiment. The neutron yield in the fast heating experiment was successfully measured using this detector.

  15. Longe-Range Order in beta-Brass Studied by Neutron Diffraction

    DEFF Research Database (Denmark)

    Rathmann, Ole; Als-Nielsen, Jens Aage

    1974-01-01

    The long-range order, M(T), in β-brass has been measured by neutron diffraction from a small extinction-free crystal. The results agree with those obtained recently by x-ray diffraction. Near Tc our data are in accordance with a power law M(T)=D(1-T/Tc)β with the critical exponent β=0.293 as pred...

  16. 10-decade wide-range neutron-monitoring system. Final test report

    Energy Technology Data Exchange (ETDEWEB)

    Green, W.K.

    1970-10-01

    The objective of Project Agreement 49 was to design, fabricate, test, and evaluate under actual nuclear reactor operating conditions, one prototype counting-Campbelling wide-range type thermal neutron flux measurement channel. This report describes the basic system designed for PA 49, and describes and presents the results of tests conducted on the system. Individual module descriptions and schematics are contained in the instruction manual which was issued with the system.

  17. Fast Neutron Spectrum Potassium Worth for Space Power Reactor Design Validation

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Briggs, J. Blair [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tsiboulia, Anatoli [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rozhikhin, Yevgeniy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mihalczo, John T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    A variety of critical experiments were constructed of enriched uranium metal (oralloy ) during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, one was performed that consisted of uranium metal annuli surrounding a potassium-filled, stainless steel can. The outer diameter of the annuli was approximately 13 inches (33.02 cm) with an inner diameter of 7 inches (17.78 cm). The diameter of the stainless steel can was 7 inches (17.78 cm). The critical height of the configurations was approximately 5.6 inches (14.224 cm). The uranium annulus consisted of multiple stacked rings, each with radial thicknesses of 1 inch (2.54 cm) and varying heights. A companion measurement was performed using empty stainless steel cans; the primary purpose of these experiments was to test the fast neutron cross sections of potassium as it was a candidate for coolant in some early space power reactor designs.The experimental measurements were performed on July 11, 1963, by J. T. Mihalczo and M. S. Wyatt (Ref. 1) with additional information in its corresponding logbook. Unreflected and unmoderated experiments with the same set of highly enriched uranium metal parts were performed at the Oak Ridge Critical Experiments Facility in the 1960s and are evaluated in the International Handbook for Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) with the identifier HEU MET FAST 051. Thin

  18. Measurement of the thermal and fast neutron flux in a research reactor with a Li and Th loaded optical fibre detector

    CERN Document Server

    Yamane, Y; Misawa, T; Karlsson, J K H; Pázsit, I

    1999-01-01

    The spatial dependence of thermal and fast neutron flux was measured axially in the core of a 1 MW research reactor. The measurements were made by a thin optical fibre detector with a neutron sensitive ZnS(Ag) scintillation tip. For thermal neutrons sup 6 Li was used, whereas for fast neutrons sup 2 sup 3 sup 2 Th was used as neutron converter. The spatial dependence was measured by moving the fibre axially with a uniform speed. The measurement takes a few minutes, compared to up to 10 h with the conventional wire activation method. Comparison with traditional measurements shows a good agreement. (author)

  19. Test case specifications for coupled neutronics-thermal hydraulics calculation of Gas-cooled Fast Reactor

    Science.gov (United States)

    Osuský, F.; Bahdanovich, R.; Farkas, G.; Haščík, J.; Tikhomirov, G. V.

    2017-01-01

    The paper is focused on development of the coupled neutronics-thermal hydraulics model for the Gas-cooled Fast Reactor. It is necessary to carefully investigate coupled calculations of new concepts to avoid recriticality scenarios, as it is not possible to ensure sub-critical state for a fast reactor core under core disruptive accident conditions. Above mentioned calculations are also very suitable for development of new passive or inherent safety systems that can mitigate the occurrence of the recriticality scenarios. In the paper, the most promising fuel material compositions together with a geometry model are described for the Gas-cooled fast reactor. Seven fuel pin and fuel assembly geometry is proposed as a test case for coupled calculation with three different enrichments of fissile material in the form of Pu-UC. The reflective boundary condition is used in radial directions of the test case and vacuum boundary condition is used in axial directions. During these condition, the nuclear system is in super-critical state and to achieve a stable state (which is numerical representation of operational conditions) it is necessary to decrease the reactivity of the system. The iteration scheme is proposed, where SCALE code system is used for collapsing of a macroscopic cross-section into few group representation as input for coupled code NESTLE.

  20. Neutronic Assessment of Transmutation Target Compositions in Heterogeneous Sodium Fast Reactor Geometries

    Energy Technology Data Exchange (ETDEWEB)

    Samuel E. Bays; Rodolfo M. Ferrer; Michael A. Pope; Benoit Forget; Mehdi Asgari

    2008-02-01

    The sodium fast reactor is under consideration for consuming the transuranic waste in the spent nuclear fuel generated by light water reactors. This work is concerned with specialized target assemblies for an oxide-fueled sodium fast reactor that are designed exclusively for burning the americium and higher mass actinide component of light water reactor spent nuclear fuel (SNF). The associated gamma and neutron radioactivity, as well as thermal heat, associated with decay of these actinides may significantly complicate fuel handling and fabrication of recycled fast reactor fuel. The objective of using targets is to isolate in a smaller number of assemblies these concentrations of higher actinides, thus reducing the volume of fuel having more rigorous handling requirements or a more complicated fabrication process. This is in contrast to homogeneous recycle where all recycled actinides are distributed among all fuel assemblies. Several heterogeneous core geometries were evaluated to determine the fewest target assemblies required to burn these actinides without violating a set of established fuel performance criteria. The DIF3D/REBUS code from Argonne National Laboratory was used to perform the core physics and accompanying fuel cycle calculations in support of this work. Using the REBUS code, each core design was evaluated at the equilibrium cycle condition.

  1. Neutron-emission measurements at a white neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Haight, Robert C [Los Alamos National Laboratory

    2010-01-01

    Data on the spectrum of neutrons emittcd from neutron-induced reactions are important in basic nuclear physics and in applications. Our program studies neutron emission from inelastic scattering as well as fission neutron spectra. A ''white'' neutron source (continuous in energy) allows measurements over a wide range of neutron energies all in one experiment. We use the tast neutron source at the Los Alamos Neutron Science Center for incident neutron energies from 0.5 MeV to 200 MeV These experiments are based on double time-of-flight techniques to determine the energies of the incident and emitted neutrons. For the fission neutron measurements, parallel-plate ionization or avalanche detectors identify fission in actinide samples and give the required fast timing pulse. For inelastic scattering, gamma-ray detectors provide the timing and energy spectroscopy. A large neutron-detector array detects the emitted neutrons. Time-of-flight techniques are used to measure the energies of both the incident and emitted neutrons. Design considerations for the array include neutron-gamma discrimination, neutron energy resolution, angular coverage, segmentation, detector efficiency calibration and data acquisition. We have made preliminary measurements of the fission neutron spectra from {sup 235}U, {sup 238}U, {sup 237}Np and {sup 239}Pu. Neutron emission spectra from inelastic scattering on iron and nickel have also been investigated. The results obtained will be compared with evaluated data.

  2. Methodology for the use of proportional counters in pulsed fast neutron yield measurements

    OpenAIRE

    Tarifeño-Saldivia, Ariel; Mayer, Roberto E.; Pavez, Cristian; Soto, Leopoldo

    2011-01-01

    This paper introduces in full detail a methodology for the measurement of neutron yield and the necessary efficiency calibration, to be applied to the intensity measurement of neutron bursts where individual neutrons are not resolved in time, for any given moderated neutron proportional counter array. The method allows efficiency calibration employing the detection neutrons arising from an isotopic neutron source. Full statistical study of the procedure is descripted, taking into account cont...

  3. Pairing in high-density neutron matter including short- and long-range correlations

    CERN Document Server

    Ding, D; Dickhoff, W H; Dussan, H; Polls, A; Witte, S J

    2015-01-01

    The influence of short-range correlations (SRC) on the spectral distribution of neutrons is incorporated in the solution of the gap equation for the ${}^3P_2-{}^3F_2$ coupled channel in pure neutron matter at high density. This effect is studied for three different realistic interactions. The gap in this channel is strongly suppressed by these correlations but does not vanish. For a consistent treatment we also include for the first time the effect of long-range correlations (LRC) by incorporating polarization terms in addition to the bare interaction. This allows the neutrons to exchange density and spin fluctuations governed by the strength of Landau parameters with values that are consistent with the available literature. While these LRC have an antiscreening tendency, they only slightly increase the gap in the ${}^3P_2-{}^3F_2$ coupled channel for all three realistic interactions as long as SRC are included. All three interactions generate maximum gaps around 0.1 to 0.2 MeV at most with a small dependence...

  4. FEASIBILITY OF MEASURING IRON IN VIVO USING FAST 14 MEV NEUTRONS.

    Energy Technology Data Exchange (ETDEWEB)

    WIELOPOLSKI, L.

    2005-05-01

    In this short report, I reassess the feasibility of measuring iron in vivo in the liver and heart of thalassemia patients undergoing chelation therapy. Despite the multiplicity of analytical methods for analyzing iron, only two, magnetic resonance imaging, and magnetic susceptibility, are suitable for in vivo applications, and these are limited to the liver because of the heart's beat. Previously, a nuclear method, gamma-resonance scattering, offered a quantitative measure of iron in these organs; however, it was abandoned because it necessitated a nuclear reactor to produce the radioactive source. I reviewed and reassessed the status of two alternative nuclear methods, based on iron spectroscopy of gamma rays induced by fast neutron inelastic scattering and delayed activation in iron. Both are quantitative methods with high specificity for iron and adequate penetrating power to measure it in organs sited deep within the human body. My experiments demonstrated that both modalities met the stated qualitative objectives to measure iron. However, neutron dosimetry revealed that the intensity of the neutron radiation field was too weak to reliably assess the minimum detection limits, and to allow quantitative extrapolations to measurements in people. A review of the literature, included in this report, showed that these findings agree qualitatively with the published results, although the doses reported were about three orders-of-magnitude higher than those I used. Reviewing the limitations of the present work, steps were outlined for overcoming some of the shortcomings. Due to a dearth of valid quantitative alternatives for determining iron in vivo, I conclude that nuclear methods remain the only viable option. However, from the lessons learned, further systematic work is required before embarking on clinical studies.

  5. Neutron polarimetry in the momentum range 1-6 GeV

    Directory of Open Access Journals (Sweden)

    Wang Ying

    2017-01-01

    Full Text Available In the framework of the ALPOM II experiment, we compare the figure of Merit of two processes for the neutron analyzing power measurement in the reactions n→+p→n→+p$\\vec n + p \\to \\vec n + p$ and n→+p→p+n→$\\vec n + p \\to p + \\vec n$ in the beam momentum range from 1 to 6 GeV. Based on a pole model calculation for the cross sections and existing data for analyzing powers, this study suggests that for neutron momentum larger than 3 GeV, the process of n→+p→p+n→$\\vec n + p \\to p + \\vec n$ is more effective for polarimetry.

  6. Elucidating the Molecular Deformation Mechanism of Entangled Polymers in Fast Flow by Small Angle Neutron Scattering

    Science.gov (United States)

    Wang, Yangyang; Sanchez-Diaz, Luis; Cheng, Shiwang; Hong, Kunlun; Chen, Wei-Ren; Liu, Jianning; Lin, Panpan; Wang, Shi-Qing

    Understanding the viscoelastic properties of polymers is of fundamental and practical importance because of the vast and ever expanding demand of polymeric materials in daily life. Our current theoretical framework for describing the nonlinear flow behavior of entangled polymers is built upon the tube model pioneered by de Gennes, Doi, and Edwards. In this work, we critically examine the central hypothesis of the tube model for nonlinear rheology using small angle neutron scattering (SANS). While the tube model envisions a unique non-affine elastic deformation mechanism for entangled polymers, our SANS measurements show that the evolution of chain conformation of a well-entangled polystyrene melt closely follows the affine deformation mechanism in uniaxial extension, even when the Rouse Weissenberg number is much smaller than unity. This result provides a key clue for understanding the molecular deformation mechanism of entangled polymers in fast flow. Several implications from our analysis will be discussed in this talk.

  7. Development of a fast traveling-wave beam chopper for the National Spallation Neutron Source

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S.S.; Jason, A.J.; Krawczyk, F.L.; Power, J.

    1997-10-01

    High current and severe restrictions on beam losses, below 1 nA/m, in the designed linac for the National Spallation Neutron Source (NSNS) require clean and fast--with the rise time from 2% to 98% less than 2.5 ns to accommodate a 402.5-MHz beam structure--beam chopping in its front end, at the beam energy 2.5 MeV. The R and D program includes both modification of the existing LANSCE coax-plate chopper to reduce parasitic coupling between adjacent plates, and development of new traveling-wave deflecting structures, in particular, based on a meander line. Using analytical methods and three-dimensional time-domain computer simulations the authors study transient effects in such structures to choose an optimal chopper design.

  8. Fuel pin and subassembly heterogeneity effect on neutronics properties of a fast power reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kamei, T.; Yoshida, T. [Nippon Atomic Industry Group Co., Ltd., Tokyo (Japan)

    1980-09-15

    Heterogeneous structure of a fuel pin subassembly may exert influence on the neutronic properties of a fast power reactor such as criticality factor, sodium void reactivity, and Doppler coefficient. Study was performed to examine this effect quantitatively for a typical 1000 MW(e) power reactor. The heterogeneity effect was evaluated in two steps. One is for the heterogeneity of fuel pin cell loaded inside wrapper tubes. Another is for the gross heterogeneity of a subassembly, namely the lumped fuel-pins in the central part and the peripheral wrapper tube region. It is shown that the combined heterogeneity effect on k/sub eff/ is as large as 0.6%{Delta}/k. This large heterogeneity is mainly caused by the {sup 238}U resonance self-shielding effect.

  9. Fast Neutron Tomography of Low-Z Object in High-Z Material Shielding

    Science.gov (United States)

    Babai, Ruth Weiss; Sabo-Napadensky, Iris; Bar, Doron; Mor, Ilan; Tamim, Noam; Dangendorf, Volker; Tittelmeier, Kai; Bromberger, Benjamin; Weierganz, Mathias

    The technique and first results of Fast Neutron Tomography (FNCT) experiments are presented which are performed at the accelerator facility of PTB, Germany. A high-intensity neutron beam of broad spectral distribution with an average energy of 5.5 MeV, was produced by 11.5 MeV deuterons impinging upon a thick beryllium target. The capability of FNCT for high contrast imaging of low-Z materials embedded in thick high-Z shielding materials is demonstrated, which is superior to more conventional high-energy X-ray imaging techniques. For demonstrating the method special test objects were prepared: One consisted of an assembled polyethylene cylinder with holes of various diameters and directions drilled in its surface and inner parts. The plastic phantom was inserted into lead cylinders of different thicknesses. The detector system consisted of a plastic scintillator along with a dedicated optics, image-intensifier and a CCD camera. Two scintillator screens were compared: a bulk plastic scintillator screen and a fibres optical scintillator screen. The tomographic scans were taken in two geometrical configurations: cone beam and semi-fan beam configuration. The image quality favours the semi-fan beam configuration which on the other hand is more time consuming The obtained tomographic images and a comparison of the imaging quality between the different experimental conditions will be presented.

  10. Monte-Carlo Simulations of Radiation-Induced Activation in a Fast-Neutron and Gamma- Based Cargo Inspection System

    CERN Document Server

    Bromberger, B; Brandis, M; Dangendorf, V; Goldberg, M B; Kaufmann, F; Mor, I; Nolte, R; Schmiedel, M; Tittelmeier, K; Vartsky, D; Wershofen, H

    2012-01-01

    An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspection facility is the inventory and lifetimes of radioactive isotopes produced by the neutron and gamma radiation inside the cargo, as well as the dose delivered by these isotopes to people in contact with the cargo during and following the interrogation procedure. Using MCNPX and CINDER90 we have calculated the activation levels for several typical inspection scenarios. One example is the activation of various metal samples embedded in a cotton-filled container. To validate the simulation results, a benchmark experiment was performed, in which metal samples were activated by fast-neutrons in a water-filled glass jar. T...

  11. Development of ionization technique for measurement of fast neutron induced fission products yields of {sup 237}Np

    Energy Technology Data Exchange (ETDEWEB)

    Goverdovski, A.A.; Khryachkov, V.A.; Ketlerov, V.V.; Mitrofanov, V.F.; Ostapenko, Yu.B.; Semenova, N.N.; Fomichev, A.N.; Rodina, L.F. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-03-01

    Twin gridded ionization chamber and corresponding software was designed for measurements of masses, kinetic energies and nuclear charges of fission fragments from fast neutron induced fission of {sup 237}Np. The ionization detector design, electronics, data acquisition and processing system and the test results are presented in this paper. (J.P.N.)

  12. Inverse magnetocaloric effect in Ce(Fe0.96Ru0.04)2: Effect of fast neutron irradiation

    Science.gov (United States)

    Dube, V.; Mishra, P. K.; Rajarajan, A. K.; Prajapat, C. L.; Sastry, P. U.; Thakare, S. V.; Singh, M. R.; Ravikumar, G.

    2013-02-01

    We have shown the effect of fast neutron irradiation on the magnetic phase transition and magnetocaloric effect (MCE) in a doped Ce(Fe0.96Ru0.04)2, intermettalic. We show that this leads to suppression of MCE and a to a disordered ferromagnetic phase.

  13. Influence of temperature on the behaviour of INTEGRAL n-type HPGe detectors irradiated with fast neutrons

    CERN Document Server

    Kandel, B; Albernhe, F; Frabel, P; Cordier, B; Tauzin, G; Crespin, S; Coszach, R; Denis, J M; Leleux, P

    1999-01-01

    Several INTEGRAL n-type HPGe detectors have been irradiated by fast neutrons at different temperatures and their performances have been evaluated. Their behaviour during warm-up and cool-down cycles following the irradiations show evidence for irreversible temperature effects above 100 K. The detectors recovery after annealing was also studied.

  14. X-Ray- and fast neutron induced mutations in Arabidopsis thaliana, and the effect of dithiothreitol upon the mutant spectrum

    NARCIS (Netherlands)

    Dellaert, L.M.W.

    1980-01-01

    The genetic effects of X-ray and fast neutron seed-irradiation of Arabidopsis thaliana (L.) Heynh., and the influence of a pre-irradiation treatment with the radio-protector dithiothreitol (DTT), are the main subjects of this thesis.Chapters I and II deal with the effects of radiation - with or with

  15. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 158B/159A

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walker, Billy Justin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-11-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 158B/159A which were measured by the Radiation Measurements Laboratory (RML).

  16. Development of ionization technique for measurement of fast neutron induced fission products yields of {sup 237}Np

    Energy Technology Data Exchange (ETDEWEB)

    Goverdovski, A.A.; Khryachkov, V.A.; Ketlerov, V.V.; Mitrofanov, V.F.; Ostapenko, Yu.B.; Semenova, N.N.; Fomichev, A.N.; Rodina, L.F. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-03-01

    Twin gridded ionization chamber and corresponding software was designed for measurements of masses, kinetic energies and nuclear charges of fission fragments from fast neutron induced fission of {sup 237}Np. The ionization detector design, electronics, data acquisition and processing system and the test results are presented in this paper. (J.P.N.)

  17. A novel fast-neutron tomography system based on a plastic scintillator array and a compact D-D neutron generator.

    Science.gov (United States)

    Adams, Robert; Zboray, Robert; Prasser, Horst-Michael

    2016-01-01

    Very few experimental imaging studies using a compact neutron generator have been published, and to the knowledge of the authors none have included tomography results using multiple projection angles. Radiography results with a neutron generator, scintillator screen, and camera can be seen in Bogolubov et al. (2005), Cremer et al. (2012), and Li et al. (2014). Comparable results with a position-sensitive photomultiplier tube can be seen in Popov et al. (2011). One study using an array of individual fast neutron detectors in the context of cargo scanning for security purposes is detailed in Eberhardt et al. (2005). In that case, however, the emphasis was on very large objects with a resolution on the order of 1cm, whereas this study focuses on less massive objects and a finer spatial resolution. In Andersson et al. (2014) three fast neutron counters and a D-T generator were used to perform attenuation measurements of test phantoms. Based on the axisymmetry of the test phantoms, the single-projection information was used to calculate radial attenuation distributions of the object, which was compared with the known geometry. In this paper a fast-neutron tomography system based on an array of individual detectors and a purpose-designed compact D-D neutron generator is presented. Each of the 88 detectors consists of a plastic scintillator read out by two Silicon photomultipliers and a dedicated pulse-processing board. Data acquisition for all channels was handled by four single-board microcontrollers. Details of the individual detector design and testing are elaborated upon. Using the complete array, several fast-neutron images of test phantoms were reconstructed, one of which was compared with results using a Co-60 gamma source. The system was shown to be capable of 2mm resolution, with exposure times on the order of several hours per reconstructed tomogram. Details about these measurements and the analysis of the reconstructed images are given, along with a discussion

  18. Preliminary studies leading to a conceptual design of a 1000 MWe fast neutron reactor; Etudes preliminaires conduisant a un concept de reacteur a neutrons rapides de 1000 MWe

    Energy Technology Data Exchange (ETDEWEB)

    Vendryes, G.; Zaleski, C.P. [Association Euratom-CEA Cadarache (France). Centre d' Etudes Nucleaires

    1964-07-01

    This report presents the results of studies which seemed important to undertake in connexion with the development of fast neutron reactors. - It points out the advantage of high internal breeding ratios ({approx}1, 1) which are necessary in order to get a small change in time both in power distribution and reactivity (less: than 0.005 {delta}k/k in 18 months). - It shows how to achieve this goal, when simultaneously power distribution flattening is obtained. These results in a higher mean specific power (which is an economic gain) and therefore in a smaller doubling time (about 10 years). - It attempts to find criteria concerning the specific power that should be used in future reactor designs -It presents a conceptional design of a 1000 MWe fast neutron reactor, for the realisation of which no technological impossibility appears. - It shows that the dynamic behaviour seems satisfactory despite a positive total isothermal sodium coefficient. - It tries to predict the development of fast reactors within the future total nuclear program. It does not appear that fissile materials supply problems should in France slow down the development of fast neutron reactors, which will be essentially tied up to its economical ability to produce cheap electric power. (authors) [French] Ce rapport presente les etudes qu'il nous a paru important d'aborder dans le cadre du developpement des reacteurs a neutrons rapides. - Il met en evidence l'interet des taux de regeneration internes eleves ({approx}1, 1) pour obtenir une bonne evolution dans le temps de la distribution de puissance et de la reactivite (moins de 0,005 {delta}k/k pour 18 mois). - Il montre la possibilite d'y parvenir tout en applatissant la distribution des fissions, ce qui se traduit par une puissance specifique moyenne plus elevee (gain economique), et donc un temps de doublement plus faible de l'ordte de 10 ans - Il tente de definir un optimum de la puissance specifique valable pour les

  19. Broad iron line in the fast spinning neutron-star system 4U 1636-53

    CERN Document Server

    Sanna, Andrea; Mendez, Mariano; Altamirano, Diego; Belloni, Tomaso; Linares, Manuel

    2013-01-01

    We analysed the X-ray spectra of six observations, simultaneously taken with XMM-Newton and Rossi X-ray Timing Explorer (RXTE), of the neutron star low-mass X-ray binary 4U 1636-53. The observations cover several states of the source, and therefore a large range of inferred mass accretion rate. These six observations show a broad emission line in the spectrum at around 6.5 keV, likely due to iron. We fitted this line with a set of phenomenological models of a relativistically broadened line, plus a model that accounts for relativistically smeared and ionised reflection from the accretion disc. The latter model includes the incident emission from both the neutron-star surface or boundary layer and the corona that is responsible for the high-energy emission in these systems. From the fits with the reflection model we found that in four out of the six observations the main contribution to the reflected spectrum comes from the neutron-star surface or boundary layer, whereas in the other two observations the main ...

  20. SiC-based neutron detector in quasi-realistic working conditions: efficiency and stability at room and high temperature under fast neutron irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Ferone, Raffaello; Issa, Fatima; Ottaviani, Laurent; Biondo, Stephane; Vervisch, Vanessa [IM2NP, UMR CNRS 7334, Aix-Marseille University, Case 231,13397 Marseille Cedex 20, (France); Szalkai, Dora; Klix, Axel [KIT- Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology Karlsruhe 76344, (Germany); Vermeeren, Ludo [SCK-CEN, Boeretang 200, B-2400 Mol, (Belgium); Saenger, Richard [Schlumberger, Clamart, (France); Lyoussi, Abadallah [CEA, DEN, Departement d' Etudes des Reacteurs, Service de Physique Experimentale, Laboratoire Dosimetrie Capteurs Instrumentation, 13108 Saint-Paul-lez-Durance, (France)

    2015-07-01

    In the framework of the European I SMART project, we have designed and made new SiC-based nuclear radiation detectors able to operate in harsh environments and to detect both fast and thermal neutrons. In this paper, we report experimental results of fast neutron irradiation campaign at high temperature (106 deg. C) in quasi-realistic working conditions. Our device does not suffer from high temperature, and spectra do show strong stability, preserving features. These experiments, as well as others in progress, show the I SMART SiC-based device skills to operate in harsh environments, whereas other materials would strongly suffer from degradation. Work is still demanded to test our device at higher temperatures and to enhance efficiency in order to make our device fully exploitable from an industrial point of view. (authors)

  1. Fast neutron cross section measurements. Final technical report, March 1, 1987--September 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, G.F.

    1997-06-01

    The time-of-flight technique was used with the ring scattering geometry in a laboratory with low neutron scattering background to measure the angular distributions of the cross sections for elastic and inelastic scattering of 14 MeV neutrons in natural chromium, iron, nickel, and niobium. Specifically for inelastic scattering included were: the 1.43 MeV and 4.56 MeV levels of {sup 52}Cr, the 0.85 MeV level, and (2.94-3.12) MeV and (4.46-4.51) MeV level groups of {sup 56}Fe, the 1.33 MeV level of {sup 60}Ni combined with the 1.45 MeV level of {sup 58}Ni, and the 4.48 MeV level of {sup 58}Ni. Pulses of neutrons with time width of 0.9-1.1 ns were produced via the {sup 3}H(d,n){sup 4}He reaction in a 150 keV Cockcroft-Walton linear accelerator, with average intensities of 9x10{sup 8} n/s. The energy of the incident neutrons was between 14.75 MeV (at 16{degree}) and 13.48 MeV (at 160{degree}). High purity scattering ring samples were used. The scattering angles ranged from {approx}16{degree} to {approx}150{degree}, for iron, chromium, and nickel, and from {approx}16{degree} to {approx}160{degree} for niobium, with a typical step of {approx}10{degree}. High purity ring samples were used.

  2. Energy spectra unfolding of fast neutron sources using the group method of data handling and decision tree algorithms

    Science.gov (United States)

    Hosseini, Seyed Abolfazl; Afrakoti, Iman Esmaili Paeen

    2017-04-01

    Accurate unfolding of the energy spectrum of a neutron source gives important information about unknown neutron sources. The obtained information is useful in many areas like nuclear safeguards, nuclear nonproliferation, and homeland security. In the present study, the energy spectrum of a poly-energetic fast neutron source is reconstructed using the developed computational codes based on the Group Method of Data Handling (GMDH) and Decision Tree (DT) algorithms. The neutron pulse height distribution (neutron response function) in the considered NE-213 liquid organic scintillator has been simulated using the developed MCNPX-ESUT computational code (MCNPX-Energy engineering of Sharif University of Technology). The developed computational codes based on the GMDH and DT algorithms use some data for training, testing and validation steps. In order to prepare the required data, 4000 randomly generated energy spectra distributed over 52 bins are used. The randomly generated energy spectra and the simulated neutron pulse height distributions by MCNPX-ESUT for each energy spectrum are used as the output and input data. Since there is no need to solve the inverse problem with an ill-conditioned response matrix, the unfolded energy spectrum has the highest accuracy. The 241Am-9Be and 252Cf neutron sources are used in the validation step of the calculation. The unfolded energy spectra for the used fast neutron sources have an excellent agreement with the reference ones. Also, the accuracy of the unfolded energy spectra obtained using the GMDH is slightly better than those obtained from the DT. The results obtained in the present study have good accuracy in comparison with the previously published paper based on the logsig and tansig transfer functions.

  3. Neutron$-^{19}$C scattering: emergence of universal properties in a finite range potential

    CERN Document Server

    Shalchi, M A; Hadizadeh, M R; Frederico, T; Tomio, Lauro

    2016-01-01

    The low-energy properties of the elastic $s-$wave scattering for the $n-^{19}$C are studied near the critical condition for the occurrence of an excited Efimov state in $n-n-^{18}$C. It is established to which extent the universal scaling laws, strictly valid in the zero-range limit, survive when finite range potentials are considered. By fixing the two-neutrons separation energy in $^{20}$C with available experimental data, it is studied the scaling of the real ($\\delta_0^R$) and imaginary parts of the $s-$wave phase-shift with the variation of the $n-^{18}$C binding energy. We obtain some universal characteristics given by the pole-position of $k\\cot(\\delta_0^R)$ and effective-range parameters. By increasing the $n-^{18}$C binding energy, it was verified that the excited state of $^{20}$C goes to a virtual state, resembling the neutron-deuteron behavior in the triton. It is confirmed that the analytical structure of the unitary cut is not affected by the range of the potential or mass asymmetry of the three...

  4. Neutron-19C scattering: Emergence of universal properties in a finite range potential

    Science.gov (United States)

    Shalchi, M. A.; Yamashita, M. T.; Hadizadeh, M. R.; Frederico, T.; Tomio, Lauro

    2017-01-01

    The low-energy properties of the elastic s-wave scattering for the n-19C are studied near the critical condition for the occurrence of an excited Efimov state in n-n-18C. It is established to which extent the universal scaling laws, strictly valid in the zero-range limit, survive when finite range potentials are considered. By fixing the two-neutrons separation energy in 20C with available experimental data, it is studied the scaling of the real (δ0R) and imaginary parts of the s-wave phase-shift with the variation of the n-18C binding energy. We obtain some universal characteristics given by the pole-position of kcot ⁡ (δ0R) and effective-range parameters. By increasing the n-18C binding energy, it was verified that the excited state of 20C goes to a virtual state, resembling the neutron-deuteron behavior in the triton. It is confirmed that the analytical structure of the unitary cut is not affected by the range of the potential or mass asymmetry of the three-body system.

  5. Covariance generation and uncertainty propagation for thermal and fast neutron induced fission yields

    Science.gov (United States)

    Terranova, Nicholas; Serot, Olivier; Archier, Pascal; De Saint Jean, Cyrille; Sumini, Marco

    2017-09-01

    Fission product yields (FY) are fundamental nuclear data for several applications, including decay heat, shielding, dosimetry, burn-up calculations. To be safe and sustainable, modern and future nuclear systems require accurate knowledge on reactor parameters, with reduced margins of uncertainty. Present nuclear data libraries for FY do not provide consistent and complete uncertainty information which are limited, in many cases, to only variances. In the present work we propose a methodology to evaluate covariance matrices for thermal and fast neutron induced fission yields. The semi-empirical models adopted to evaluate the JEFF-3.1.1 FY library have been used in the Generalized Least Square Method available in CONRAD (COde for Nuclear Reaction Analysis and Data assimilation) to generate covariance matrices for several fissioning systems such as the thermal fission of U235, Pu239 and Pu241 and the fast fission of U238, Pu239 and Pu240. The impact of such covariances on nuclear applications has been estimated using deterministic and Monte Carlo uncertainty propagation techniques. We studied the effects on decay heat and reactivity loss uncertainty estimation for simplified test case geometries, such as PWR and SFR pin-cells. The impact on existing nuclear reactors, such as the Jules Horowitz Reactor under construction at CEA-Cadarache, has also been considered.

  6. Fast determination of impurities in metallurgical grade silicon for photovoltaics by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, J., E-mail: jonathan.hampel@ise.fraunhofer.de [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, D-79110 Freiburg (Germany); Boldt, F.M. [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, D-79110 Freiburg (Germany); Gerstenberg, H. [ZWE FRM-II der Technischen Universitaet Muenchen, D-85748 Garching (Germany); Hampel, G.; Kratz, J.V. [Institute of Nuclear Chemistry, Johannes Gutenberg-University of Mainz, Fritz-Strassmann-Weg 2, D-55128 Mainz (Germany); Reber, S. [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, D-79110 Freiburg (Germany); Wiehl, N. [Institute of Nuclear Chemistry, Johannes Gutenberg-University of Mainz, Fritz-Strassmann-Weg 2, D-55128 Mainz (Germany)

    2011-10-15

    Standard wafer solar cells are made of near-semiconductor quality silicon. This high quality material makes up a significant part of the total costs of a solar module. Therefore, new concepts with less expensive so called solar grade silicon directly based on physiochemically upgraded metallurgical grade silicon are investigated. Metallurgical grade silicon contains large amounts of impurities, mainly transition metals like Fe, Cr, Mn, and Co, which degrade the minority carrier lifetime and thus the solar cell efficiency. A major reduction of the transition metal content occurs during the unidirectional crystallization due to the low segregation coefficient between the solid and liquid phase. A further reduction of the impurity level has to be done by gettering procedures applied to the silicon wafers. The efficiency of such cleaning procedures of metallurgical grade silicon is studied by instrumental neutron activation analysis (INAA). Small sized silicon wafers of approximately 200 mg with and without gettering step were analyzed. To accelerate the detection of transition metals in a crystallized silicon ingot, experiments of scanning whole vertical silicon columns with a diameter of approximately 1 cm by gamma spectroscopy were carried out. It was demonstrated that impurity profiles can be obtained in a comparably short time. Relatively constant transition metal ratios were found throughout an entire silicon ingot. This led to the conclusion that the determination of several metal profiles might be possible by the detection of only one 'leading element'. As the determination of Mn in silicon can be done quite fast compared to elements like Fe, Cr, and Co, it could be used as a rough marker for the overall metal concentration level. Thus, a fast way to determine impurities in photovoltaic silicon material is demonstrated. - Highlights: > We demonstrate a fast way to determine impurities in photovoltaic silicon by NAA. > We make first experiments of

  7. A search for nEDM and new constraints on short-range "pseudo-magnetic" interaction using neutron optics of noncentrosymmetric crystal

    Science.gov (United States)

    Fedorov, V. V.; Kuznetsov, I. A.; Voronin, V. V.

    2013-08-01

    New approach to measure both neutron electric dipole moment (EDM) and short-range pseudomagnetic nucleon-nucleon interaction using neutron optics of a crystal without center of symmetry is presented. This approach allows getting best direct constraint on the parameters of short range pseudomagnetic interaction of a free neutron with matter for the range of interaction distances λ<10-7 m.

  8. Use of chemical etching of CR-39 foils at elevated temperature for fast neutron personnel monitoring in India

    Science.gov (United States)

    Sathian, Deepa; Rohatgi, Rupali; Jayalakshmi, V.; Marathe, P. K.; Nair, Sarala; Kolekar, R. V.; Chourasiya, G.; Kannan, S.

    2009-06-01

    CR-39 Solid State Nuclear Track Detecting foils (SSNTD), along with 1 mm thick polyethylene radiator, sealed in triple laminated pouches, are used for country wide Fast Neutron Personnel Monitoring in India. With the present system of processing by elevated temperature electrochemical etching (ETECE) and evaluation using automatic image analysis, only 16 foils are processed at a time and it is useful over the dose equivalent range 0.2 mSv to 10 mSv. It has been reported that, by processing CR-39 of good detection efficiency by chemical etching at elevated temperature, more numbers of foils can be processed simultaneously. In the present study, CR-39 foils from Pershore Moulding (UK) have been chemically etched using 7 N KOH under various conditions of temperature and etching durations and evaluated using high magnification microscope. The duration of chemical etching, has been optimized at a constant temperature of 60°C for chemical etching process. The characteristics of the chemically etched CR-39 foils are compared with the characteristics of the CR-39 foils processed by the existing system of ETECE and the detailed results are presented in the full text of the paper. It has been observed that by chemical etching process, the dose equivalent range of CR-39 foils can be extended above 60 mSv.

  9. Novel technologies and theoretical models in radiation therapy of cancer patients using 6.3 MeV fast neutrons produced by U-120 cyclotron

    Science.gov (United States)

    Musabaeva, L. I.; Startseva, Zh. A.; Gribova, O. V.; Velikaya, V. V.; Lisin, V. A.

    2016-08-01

    The analysis of clinical use of neutron therapy with 6 MeV fast neutrons compared to conventional radiation therapy was carried out. The experience of using neutron and mixed neutron and photon therapy in patients with different radio-resistant malignant tumors shows the necessity of further studies and development of the novel approaches to densely-ionizing radiation. The results of dosimetry and radiobiological studies have been the basis for planning clinical programs for neutron therapy. Clinical trials over the past 30 years have shown that neutron therapy successfully destroys radio-resistant cancers, including salivary gland tumors, adenoidcystic carcinoma, inoperable sarcomas, locally advanced head and neck tumors, and locally advanced prostate cancer. Radiation therapy with 6.3 MeV fast neutrons used alone and in combination with photon therapy resulted in improved long-term treatment outcomes in patients with radio-resistant malignant tumors.

  10. Novel technologies and theoretical models in radiation therapy of cancer patients using 6.3 MeV fast neutrons produced by U-120 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Musabaeva, L. I., E-mail: musabaevaLI@oncology.tomsk.ru; Lisin, V. A., E-mail: Lisin@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Startseva, Zh. A., E-mail: zhanna.alex@rambler.ru; Gribova, O. V., E-mail: gribova79@mail.ru; Velikaya, V. V., E-mail: viktoria.v.v@inbox.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); National Research Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The analysis of clinical use of neutron therapy with 6 MeV fast neutrons compared to conventional radiation therapy was carried out. The experience of using neutron and mixed neutron and photon therapy in patients with different radio-resistant malignant tumors shows the necessity of further studies and development of the novel approaches to densely-ionizing radiation. The results of dosimetry and radiobiological studies have been the basis for planning clinical programs for neutron therapy. Clinical trials over the past 30 years have shown that neutron therapy successfully destroys radio-resistant cancers, including salivary gland tumors, adenoidcystic carcinoma, inoperable sarcomas, locally advanced head and neck tumors, and locally advanced prostate cancer. Radiation therapy with 6.3 MeV fast neutrons used alone and in combination with photon therapy resulted in improved long-term treatment outcomes in patients with radio-resistant malignant tumors.

  11. Limiting Equivalence Principle Violation and Long-Range Baryonic Force from Neutron-Antineutron Oscillation

    CERN Document Server

    Babu, K S

    2016-01-01

    We point out that if the baryon number violating neutron-antineutron oscillation is discovered, it would impose strong limits on the departure from Einstein's equivalence principle at a level of one part in $10^{19}$. If this departure owes its origin to the existence of long-range forces coupled to baryon number $B$ (or $B-L$), it would imply very stringent constraints on the strength of gauge bosons coupling to baryon number current. For instance, if the force mediating baryon number has strength $\\alpha_B$ and its range is larger than a megaparsec, we find the limit to be $\\alpha_B \\leq 2\\times 10^{-57}$, which is much stronger than all other existing bounds. For smaller range for the force, we get slightly weaker, but still stringent bounds by considering the potential of the Earth and the Sun.

  12. Conceptual design for a neutron imaging system for thick target analysis operating in the 10-15 MeV energy range

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, F.; Hall, J.; Logan, C.

    1996-09-11

    Fast neutron imaging offers the potential to be a powerful non- destructive inspection tool for evaluating the integrity of thick sealed targets. This is particularly true in cases where one is interested in detecting voids, cracks or other defects in low-Z materials (e.g. plastics, ceramics, salts, etc.) which are shielded by thick, high-Z parts. In this paper we present the conceptual design for a neutron imaging system for use in the 10 - 15 MeV energy range and discuss potential applications in the area of nuclear stockpile steward- ship. The background of this project, currently under development at LLNL, will be outlined and computer simulations will be presented which predict system performance. Efforts to assess technical risks involved in the development of the system will be discussed and the results of a recent experiment designed to evaluate background radiation levels will also be presented.

  13. Measurements of periods, relative abundances and absolute yields of delayed neutrons from fast neutron induced fission of {sup 237}Np

    Energy Technology Data Exchange (ETDEWEB)

    Piksaikine, V. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-03-01

    The experimental method for measurements of the delayed neutron yields and period is presented. The preliminary results of the total yield, relative abundances and periods are shown comparing with the previously reported values. (J.P.N.)

  14. Measurements of periods, relative abundances and absolute yields of delayed neutrons from fast neutron induced fission of {sup 237}Np

    Energy Technology Data Exchange (ETDEWEB)

    Piksaikine, V. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-03-01

    The experimental method for measurements of the delayed neutron yields and period is presented. The preliminary results of the total yield, relative abundances and periods are shown comparing with the previously reported values. (J.P.N.)

  15. High accuracy measurement of the $^{235}$U(n,f) reaction cross-section in the 10-30 keV neutron energy range

    CERN Multimedia

    The analysis of the neutron flux of n_TOF (in EAR1) revealed an anomaly in the 10-30 keV neutron energy range. While the flux extracted on the basis of the $^{6}$Li(n,t)$^{4}$He and $^{10}$B(n,$\\alpha$)$^{7}$Li reactions mostly agreed with each other and with the results of FLUKA simulations of the neutron beam, the one based on the $^{235}$U(n,f) reaction was found to be systematically lower, independently of the detection system used. A possible explanation is that the $^{235}$U(n,f) crosssection in that energy region, where in principle should be known with an uncertainty of 1%, may be systematically overestimated. Such a finding, which has a negligible influence on thermal reactors, would be important for future fast critical or subcritical reactors. Furthermore, its interest is more general, since the $^{235}$U(n,f) reaction is often used at that energy to determine the neutron flux, or as reference in measurements of fission cross section of other actinides. We propose to perform a high-accuracy, high-r...

  16. Effects of irradiation - fast neutrons and implantation on sintered Y sbnd Ba sbnd Cu sbnd O superconductors

    Science.gov (United States)

    Rao, K. V.; PuŹniak, R.; Chen, D.-X.; Karpe, N.; Baran, M.; Wiśniewski, A.; Pytel, K.; Szymczak, H.; Dyrbye, K.; Bøttiger, J.

    1988-06-01

    Effects of irradiation damage by fast neutrons, and nitrogen implantation on magnetic and electrical properties of Y sbnd Ba sbnd Cu sbnd O materials have been studied. The samples were subjected to a fluence of 2 × 10 17 and 1 × 10 17 neutrons / cm 2. In the implantation studies dosages of 10 15 and 10 16ions/ cm 2 of N + were used. Here we will report on the detailed changes in the magnetic hysteresis loop due to irradiation. It is found that the transport inter-grain critical current decreases with irradiation, while the critical current inside the grains is enhanced.

  17. A wide dynamic range BF 3 neutron monitor with front-end electronics based on a logarithmic amplifier

    Science.gov (United States)

    Ferrarini, M.; Varoli, V.; Favalli, A.; Caresana, M.; Pedersen, B.

    2010-02-01

    This paper describes a wide dynamic range neutron monitor based on a BF 3 neutron detector. The detector is used in current mode, and front-end electronics based on a logarithmic amplifier are used in order to have a measurement capability ranging over many orders of magnitude. The system has been calibrated at the Polytechnic of Milan, CESNEF, with an AmBe neutron source, and has been tested in a pulsed field at the PUNITA facility at JRC, Ispra. The detector has achieved a dynamic range of over 6 orders of magnitude, being able to measure single neutron pulses and showing saturation-free response for a reaction rate up to 10 6 s -1. It has also proved effective in measuring the PUNITA facility pulse integral fluence.

  18. A wide dynamic range BF{sub 3} neutron monitor with front-end electronics based on a logarithmic amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Ferrarini, M., E-mail: michele.ferrarini@polimi.i [Politecnico di Milano, Dipartimento Energia, via G. Ponzio 34/3, I-20133 Milano (Italy); Fondazione CNAO, via Caminadella 16, 20123 Milano (Italy); Varoli, V. [Politecnico di Milano, Dipartimento Energia, via G. Ponzio 34/3, I-20133 Milano (Italy); Favalli, A. [European Commission, Joint Research Centre, Institute for the Protection and Security of Citizen, TP 800, Via E. Fermi, 21027 Ispra (Vatican City State, Holy See) (Italy); Caresana, M. [Politecnico di Milano, Dipartimento Energia, via G. Ponzio 34/3, I-20133 Milano (Italy); Pedersen, B. [European Commission, Joint Research Centre, Institute for the Protection and Security of Citizen, TP 800, Via E. Fermi, 21027 Ispra (Italy)

    2010-02-01

    This paper describes a wide dynamic range neutron monitor based on a BF{sub 3} neutron detector. The detector is used in current mode, and front-end electronics based on a logarithmic amplifier are used in order to have a measurement capability ranging over many orders of magnitude. The system has been calibrated at the Polytechnic of Milan, CESNEF, with an AmBe neutron source, and has been tested in a pulsed field at the PUNITA facility at JRC, Ispra. The detector has achieved a dynamic range of over 6 orders of magnitude, being able to measure single neutron pulses and showing saturation-free response for a reaction rate up to 10{sup 6} s{sup -1}. It has also proved effective in measuring the PUNITA facility pulse integral fluence.

  19. Fast neutron spectrometry with organic scintillators applied to magnetic fusion experiments

    CERN Document Server

    Kaschuck, Y A; Trykov, L A; Semenov, V P

    2002-01-01

    Neutron spectrometry with NE213 liquid scintillators is commonly used in thermonuclear fusion experiments to measure the 2.45 and 14.1 MeV neutron flux. We present the unfolded neutron spectrum, which was accumulated during several ohmic deuterium plasma discharges in the Frascati Tokamak Upgrade using a 2''x2'' NE213 scintillator. In this paper, we review the application of organic scintillator neutron spectrometers to tokamaks, focusing in particular on the comparison between NE213 and stilbene scintillators. Various aspects of the calibration technique and neutron spectra unfolding procedure are considered in the context of their application for fusion neutron spectrometry. Testing and calibration measurements have been carried out using D-D and D-T neutron generator facilities with both NE213 and stilbene scintillators. The main result from these measurements is that stilbene scintillator has better neutron energy resolution than NE213. Our stilbene detector could be used for the determination of the ion ...

  20. Fast neutron spectrum unfolding of a TRIGA Mark II reactor and measurement of spectrum-averaged cross sections. Integral tests of differential cross sections of neutron threshold reactions

    Energy Technology Data Exchange (ETDEWEB)

    Uddin, M.S.; Hossain, S.M.; Khan, R. [Atomic Energy Research Establishment, Dhaka (Bangladesh). Inst. of Nuclear Science and Technology (INST); Sudar, S. [Debrecen Univ. (Hungary). Inst. of Experimental Physics; Zulquarnain, M.A. [Bangladesh Atomic Energy Commission, Dhaka (Bangladesh); Qaim, S.M. [Forschungszentrum Juelich (Germany). Inst. fuer Neurowissenschaften und Medizin (INM-5)

    2013-07-01

    The spectrum of fast neutrons having energies from 0.5 to 20 MeV in the core of the 3MW TRIGA Mark II reactor at Savar, Dhaka, Bangladesh, was unfolded by activating several metal foils to induce threshold nuclear reactions covering the whole spectrum, and then doing necessary iterative calculations utilizing the activation results and the code SULSA. The analysed shape of the spectrum in the TRIGA core was found to be similar to that of the pure {sup 235}U-fission spectrum, except for the energies between 0.5 and 1.5 MeV, where it was slightly higher than the fission spectrum. Spectrum-averaged cross sections were determined by integral measurements. The integral values measured in this work were compared with the recommended values for a pure fission spectrum as well as with the integrated data deduced from measured and evaluated excitation functions of a few reactions given in some data files. The good agreement between integral measurements and integrated data in case of well-investigated reactions shows that the fast neutron field at the TRIGA Mark II reactor can be used for validation of evaluated data of neutron threshold reactions. (orig.)

  1. Tagging fast neutrons from a 252Cf fission-fragment source

    CERN Document Server

    Scherzinger, Julius; Annand, John; Fissum, Kevin; Hall-Wilton, Richard; Mauritzson, Nicholai; Messi, Francesco; Perrey, Hanno; Rofors, Emil

    2016-01-01

    Coincidence and time-of-flight measurement techniques are employed to tag fission neutrons emitted from a 252Cf source. Fission fragments detected in a gaseous 4He scintillator detector supply the tag. Neutrons are detected in a NE-213 liquid-scintillator detector. The resulting continuous polychromatic beam of tagged neutrons has an energy dependence that agrees qualitatively with expectations.

  2. A compact fast-neutron producing target for high resolution cross section measurements

    NARCIS (Netherlands)

    Flaska, M.

    2006-01-01

    A proper knowledge of neutron cross sections is very important for the operation safety of various nuclear facilities. Reducing uncertainties in the neutron cross sections can lead to an enhanced safety of present and future nuclear power systems. Accurate neutron cross sections also play a relevant

  3. Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

    Energy Technology Data Exchange (ETDEWEB)

    Schumann, M.; Mauerhofer, E. [Institute of Energy and Climate Research - Nuclear Waste Management and Reactor Safety, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany); Engels, R.; Kemmerling, G. [Central Institute for Engineering, Electronics and Analytics - Electronic Systems, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany); Frank, M. [MATHCCES - Department of Mathematics, RWTH Aachen University, 52062 Aachen (Germany); Havenith, A.; Kettler, J.; Klapdor-Kleingrothaus, T. [Institute of Nuclear Engineering and Technology Transfer, RWTH Aachen University, 52062 Aachen (Germany); Schitthelm, O. [Corporate Technology, Siemens AG, 91058 Erlangen (Germany)

    2015-07-01

    Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241

  4. Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

    CERN Document Server

    Cortesi, M; Adams, R; Dangendorf, V; Prasser, H -M

    2012-01-01

    The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, cool...

  5. Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

    Science.gov (United States)

    Cortesi, M.; Zboray, R.; Adams, R.; Dangendorf, V.; Prasser, H.-M.

    2012-02-01

    The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5 MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).

  6. Light charged particle emission induced by fast neutrons (25 to 65 MeV) on sup 5 sup 9 Co

    CERN Document Server

    Nica, N; Raeymackers, E; Slypen, I; Meulders, J P; Corcalciuc, V

    2002-01-01

    Double-differential cross sections (energy spectra) for the proton, deuteron, triton and alpha-particle production in fast neutron induced reactions on cobalt are reported for ten incident neutron energies between 25 and 65 MeV. Energy spectra were obtained at nine laboratory angles between 20 deg. and 160 deg. and extrapolated or interpolated to other ten angles covering uniformly the laboratory angular domain of 0 deg. to 180 deg. The experimental set-up and procedures for data reduction including corrections and normalization are presented and discussed. Based on the measured double-differential cross sections, energy-differential and total cross sections are reported as well. Experimental cross sections are compared with similar available data from neutron- and proton-induced reactions. Theoretical calculations based on semiclassical exciton model and Hauser-Feshbach statistical theory (GNASH code) and intranuclear cascade model for nucleon-induced interactions (INCL3 code) were done and compared to the e...

  7. Space radiation studies at the White Sands Missile Range Fast Burst Reactor

    Science.gov (United States)

    Delapaz, A.

    1972-01-01

    The operation of the White Sands Missile Range Fast Burst Reactor is discussed. Space radiation studies in radiobiology, dosimetry, and transient radiation effects on electronic systems and components are described. Proposed modifications to increase the capability of the facility are discussed.

  8. The fast neutron fluence and the activation detector activity calculations using the effective source method and the adjoint function

    Energy Technology Data Exchange (ETDEWEB)

    Hep, J.; Konecna, A.; Krysl, V.; Smutny, V. [Calculation Dept., Skoda JS plc, Orlik 266, 31606 Plzen (Czech Republic)

    2011-07-01

    This paper describes the application of effective source in forward calculations and the adjoint method to the solution of fast neutron fluence and activation detector activities in the reactor pressure vessel (RPV) and RPV cavity of a VVER-440 reactor. Its objective is the demonstration of both methods on a practical task. The effective source method applies the Boltzmann transport operator to time integrated source data in order to obtain neutron fluence and detector activities. By weighting the source data by time dependent decay of the detector activity, the result of the calculation is the detector activity. Alternatively, if the weighting is uniform with respect to time, the result is the fluence. The approach works because of the inherent linearity of radiation transport in non-multiplying time-invariant media. Integrated in this way, the source data are referred to as the effective source. The effective source in the forward calculations method thereby enables the analyst to replace numerous intensive transport calculations with a single transport calculation in which the time dependence and magnitude of the source are correctly represented. In this work, the effective source method has been expanded slightly in the following way: neutron source data were performed with few group method calculation using the active core calculation code MOBY-DICK. The follow-up neutron transport calculation was performed using the neutron transport code TORT to perform multigroup calculations. For comparison, an alternative method of calculation has been used based upon adjoint functions of the Boltzmann transport equation. Calculation of the three-dimensional (3-D) adjoint function for each required computational outcome has been obtained using the deterministic code TORT and the cross section library BGL440. Adjoint functions appropriate to the required fast neutron flux density and neutron reaction rates have been calculated for several significant points within the RPV

  9. Development of high pressure deuterium gas targets for the generation of intense mono-energetic fast neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Guzek, J. E-mail: jguzek@debeers.co.za; Richardson, K.; Franklyn, C.B.; Waites, A.; McMurray, W.R.; Watterson, J.I.W.; Tapper, U.A.S

    1999-06-01

    Two different technical solutions to the problem of generation of mono-energetic fast neutron beams on the gaseous targets are presented here. A simple and cost-effective design of a cooled windowed gas target system is described in the first part of this paper. It utilises a thin metallic foil window and circulating deuterium gas cooled down to 100 K. The ultimate beam handling capability of such target is determined by the properties of the window. Reliable performance of this gas target system was achieved at 1 bar of deuterium gas, when exposed to a 45 {mu}A beam of 5 MeV deuterons, for periods in excess of 6 h. Cooling of the target gas resulted in increased fast neutron output and improved neutron to gamma-ray ratio. The second part of this paper discusses the design of a high pressure, windowless gas target for use with pulsed, low duty cycle accelerators. A rotating seal concept was applied to reduce the gas load in a differentially pumped system. This allows operation at 1.23 bar of deuterium gas pressure in the gas cell region. Such a gas target system is free from the limitations of the windowed target but special attention has to be paid to the heat dissipation capability of the beam dump, due to the use of a thin target. The rotating seal concept is particularly suitable for use with accelerators such as radio-frequency quadrupole (RFQ) linacs that operate with a very high peak current at low duty cycle. The performance of both target systems was comprehensively characterized using the time-of-flight (TOF) technique. This demonstrated that very good quality mono-energetic fast neutron beams were produced with the slow neutron and gamma-ray component below 10% of the total target output.

  10. Tritium removal from various lithium aluminates irradiated by fast and thermal neutrons (COMPLIMENT experiment)

    Science.gov (United States)

    Alvani, C.; Carconi, P. L.; Casadio, S.; Moauro, A.

    1994-02-01

    Within the frame of the COMPLIMENT experiment, γ-LiAlO 2 specimens with different microstructures (grain size distributions) were tested in the same environmental conditions to compare the effects caused by 6Li(n, α)T reaction and by fast neutron scattering, the damaging dose being held at about the same level (1.6-1.8 dpa). The tritium retention times were obtained by the tritium removal of isothermal annealing under He + 0.1% H 2 sweeping gas. In spite of the different Li burnups (2.5% and 0.25%) and the residual tritium concentrations which were found in the irradiated specimens (4.3 Ci/g and 0.09 Ci/g, respectively, for specimens held at 450°C during the irradiations), the kinetics of tritium removal was not found to be discriminated by the two different irradiations. Moreover, the results were found to agree with those previously obtained by the "in-situ" TEQUILA experiment, performed on the same type of Li ceramics. Hence, the apparent first order desorption mechanism has been confirmed to control the kinetics of tritium removal from the porous fine grain γ-LiAlO 2 ceramics.

  11. Fast spinning neutron stars: unified equations of state, crust effects, maximum rotating configurations

    CERN Document Server

    Li, A; Qi, B; Burgio, G F

    2016-01-01

    We study the crust effects on fast-rotating configurations of neutron stars (NSs). For this aim, we employ four unified equations of state (EoS) for both the cores and crusts, namely BCPM, BSk20, BSk21, Shen-TM1, as well as two non-unified EoS widely used in the literature, i.e. APR and GM1 EoS. All the core EoSs satisfy the recent observational constraints of the two massive pulsars whose masses are precisely measured. We show that the NS mass-equatorial radius relations are slightly affected by the smoothness at the core-crust matching interface. However, the uncertainties in the crust EoS and the matching interface bring insignificant changes, even at maximally rotating (Keplerian) configurations. For all four unified EoS, rotations can increase the star's gravitational mass up to $18\\%-19\\%$ and the equatorial radius by $29\\%-36\\%$. For stars as heavy as 1.4 M$_{\\odot}$, the radius increase is more pronounced, reaching $41\\%-43\\%$, i.e. 5 - 6 km. Moreover, by comparing the present calculations with recent...

  12. Thermal stability and kinetics of defects in magnesium aluminate spinel irradiated with fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Kazuhiro E-mail: yasudak@nucl.kyushu-u.ac.jp; Kinoshita, Chiken; Fukuda, Korehisa; Garner, Frank A

    2000-12-01

    Thermal stability of interstitial-type dislocation loops and cavities in single crystals of MgAl{sub 2}O{sub 4} was examined during isochronal and isothermal annealing. The specimens were irradiated with fast-neutrons in FFTF/MOTA at 658 and 1023 K up to 249 dpa. During the isochronal annealing, dislocation loops started to shrink around 1000 K and completely disappeared at 1470 K without changing their character. Cavities grew slightly around 1570 K, and above this temperature, cavities shrunk with increasing annealing temperature. The recovery stage of point defects in MgAl{sub 2}O{sub 4} was discussed in terms of the thermal stability of defect clusters; vacancy migration starts around 1000 K (corresponding to stage III), whereas vacancy clusters start to dissociate around 1570 K (corresponding to stage V). The vacancy migration energy for rate controlling species was estimated from the shrinkage process of interstitial-type dislocation loops to be 2.0 {+-} 0.7 eV.

  13. A Neutron Star-White Dwarf Binary Model for Repeating Fast Radio Burst 121102

    CERN Document Server

    Gu, Wei-Min; Liu, Tong; Ma, Renyi; Wang, Junfeng

    2016-01-01

    We propose a compact binary model for the fast radio burst (FRB) repeaters, where the system consists of a magnetic white dwarf (WD) and a neutron star (NS) with strong bipolar magnetic fields. When the WD fills its Roche lobe, mass transfer will occur from the WD to the NS through the inner Lagrange point. The accreted magnetized materials may trigger magnetic reconnection when they approach the NS surface, and therefore the electrons can be accelerated to an ultra-relativistic speed. In this scenario, the curvature radiation of the electrons moving along the NS magnetic field lines can account for the characteristic frequency and the timescale of an FRB. Owing to the conservation of angular momentum, the WD may be kicked away after a burst, and the next burst may appear when the system becomes semi-detached again through the gravitational radiation. By comparing our analyses with the observations, we show that such an intermittent Roche lobe overflow mechanism can be responsible for the observed repeating b...

  14. Radiation damage in InGaAs photodiodes by 1 MeV fast neutrons

    CERN Document Server

    Ohyama, H; Vanhellemont, J; Takami, Y; Sunaga, H

    1998-01-01

    Irradiation damage in In sub 0 sub . sub 5 sub 3 Ga sub 0 sub . sub 4 sub 7 As p-i-n photodiodes by 1 MeV fast neutrons has been studied as a function of fluence for the first time, and the results are discussed in this paper. The degradation of the electrical and optical performance of diodes increases with increasing fluence. The induced lattice defects in the In sub 0 sub . sub 5 sub 3 Ga sub 0 sub . sub 4 sub 7 As epitaxial layers and the InP substrate are studied by Deep Level Transient Spectroscopy (DLTS) methods. In the In sub 0 sub . sub 5 sub 3 Ga sub 0 sub . sub 4 sub 7 As epitaxial layers, hole and electron capture levels are induced by irradiation. The influence of the type of radiation source on the device degradation is then discussed by comparison to 1 MeV electrons with respect to the numbers of knock-on atoms and the nonionizing energy loss (NIEL). The radiation source dependence of performance degradation is attributed to the difference of mass between the two irradiating particles and the p...

  15. Fast neutron incineration in the energy amplifier as alternative to geologic storage the case of Spain

    CERN Document Server

    Rubbia, Carlo; Kadi, Y; Rubio, Juan Antonio

    1997-01-01

    In previous reports [1][2] we have presented the conceptual design of a fast neutron driven sub-critical device (Energy Amplifier) designed both for energy amplification (production) and for the incineration of unwanted ³waste² from Nuclear Light Water Reactors (LWR). The latter scheme is here applied to the specific case of Spain, where 9 large LWR¹s are presently in operation. It is shown that a cluster of 5 EA¹s is a very effective and realistic solution to the elimination (in 37 years) of the present and foreseen (till 2029) LWR-Waste stockpiles of Spain, but with major improvements over Geologic Storage, since: (1) only a Low Level Waste (LLW) surface repository of reasonable size is ultimately required; (2) the large amount of energy stored in the trans-Uranics is recovered, amounting for each of the 37 years of incineration to a saving of about 8% of the present primary energy demand of Spain (100 MTep/y); (3) the slightly enriched (1.1%) Uranium, unburned by LWR¹s, can be recovered for further us...

  16. Tritium removal from various lithium aluminates irradiated by fast and thermal neutrons (COMPLIMENT experiment)

    Energy Technology Data Exchange (ETDEWEB)

    Alvani, C. (ENEA CRE Casaccia, INN/NUMA, Rome (Italy)); Carconi, P.L. (ENEA CRE Casaccia, INN/NUMA, Rome (Italy)); Casadio, S. (ENEA CRE Casaccia, INN/NUMA, Rome (Italy)); Moauro, A. (ENEA CRE Casaccia, INN/NUMA, Rome (Italy))

    1994-02-01

    Within the frame of the COMPLIMENT experiment, [gamma]-LiAlO[sub 2] specimens with different microstructures (grain size distributions) were tested in the same environmental conditions to compare the effects caused by [sup 6]Li(n, [alpha])T reaction and by fast neutron scattering, the damaging dose being held at about the same level (1.6-1.8 dpa). The tritium retention times were obtained by the tritium removal of isothermal annealing under He + 0.1% H[sub 2] sweeping gas. In spite of the different Li burnups (2.5% and 0.25%) and the residual tritium concentrations which were found in the irradiated specimens (4.3 Ci/g and 0.09 Ci/g, respectively, for specimens held at 450 C during the irradiations), the kinetics of tritium removal was not found to be discriminated by the two different irradiations. Moreover, the results were found to agree with those previously obtained by the ''in-situ'' TEQUILA experiment, performed on the same type of Li ceramics. Hence, the apparent first order desorption mechanism has been confirmed to control the kinetics of tritium removal from the porous fine grain [gamma]-LiAlO[sub 2] ceramics. (orig.)

  17. DETEC, a Subprogram for Simulation of the Fast-Neutron Detection Process in a Hydro-Carbonous Plastic Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, B.; Aspelund, O.

    1966-07-15

    A description is given of the subprogram DETEC, which for energies below 5 MeV simulates the detection process of a fast-neutron within a large cylindrical plastic scintillator. DETEC has been coded in FORTRAN IV, and consists of a subroutine and a BLOCK-DATA subprogram. The latter is in its present form adapted to the dimensions 5 cm diam. x 8 cm of the scintillating materials NE102 and NE102A. The character of DETEC as a subprogram is manifest through the requirement of a main routine for generation of the following input parameters: 1. fast-neutron position; 2. direction; 3. energy; 4. entrance time; 5. input weight (all referred to the detector surface), and 6. the discriminator threshold. When these are provided, the virtues of DETEC are recording of the detected weight and the time elapsed prior to the detection event. The merits of DETEC are finally demonstrated in two typical applications.

  18. A novel liquid-Xenon detector concept for combined fast-neutrons and gamma imaging and spectroscopy

    Science.gov (United States)

    Breskin, A.; Israelashvili, I.; Cortesi, M.; Arazi, L.; Shchemelinin, S.; Chechik, R.; Dangendorf, V.; Bromberger, B.; Vartsky, D.

    2012-06-01

    A new detector concept is presented for combined imaging and spectroscopy of fast-neutrons and gamma rays. It comprises a liquid-Xenon (LXe) converter and scintillator coupled to a UV-sensitive gaseous imaging photomultiplier (GPM). Radiation imaging is obtained by localization of the scintillation-light from LXe with the position-sensitive GPM. The latter comprises a cascade of Thick Gas Electron Multipliers (THGEM), where the first element is coated with a CsI UV-photocathode. We present the concept and provide first model-simulation results of the processes involved and the expected performances of a detector having a LXe-filled capillaries converter. The new detector concept has potential applications in combined fast-neutron and gamma-ray screening of hidden explosives and fissile materials with pulsed sources.

  19. High Hydrogen Content Graphene Hydride Compounds & High Cross-­ Section Cladding Coatings for Fast Neutron Detection

    Energy Technology Data Exchange (ETDEWEB)

    Chandrashekhar, MVS [Univ. of South Carolina, Columbia, SC (United States)

    2017-06-21

    The objective is to develop and implement a superior low-cost, large area (potentially >32in), easily deployable, close proximity, harsh environment innovative neutron sensor needed for next generation fuel cycle monitoring. We will exploit recent breakthroughs at the PI’s lab on the electrochemistry of epitaxial graphene (EG) formed on commercial SiC wafers, a transformative nanomaterial system with superior radiation detection and durability properties to develop a new paradigm in detection for fast neutrons, a by-product of fission reactors. There are currently few effective detection/monitoring schemes, especially solid-state ones at present. This is essential for monitoring and control of future fuel cycles to make them more efficient and reliable. By exploiting these novel materials, as well as innovative hybrid SiC/EG/Cladding device architectures conceived by the team, will develop low-cost, high performance solutions to fast-neutron detection. Finally, we will also explore 3-terminal device implementations for neutron detectors with built-in electronic gain to further shrink these devices and improve their sensitivity.

  20. Methodology for the use of proportional counters in pulsed fast neutron yield measurements

    CERN Document Server

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo

    2011-01-01

    This paper introduces in full detail a methodology for the measurement of neutron yield and the necessary efficiency calibration, to be applied to the intensity measurement of neutron bursts where individual neutrons are not resolved in time, for any given moderated neutron proportional counter array. The method allows efficiency calibration employing the detection neutrons arising from an isotopic neutron source. Full statistical study of the procedure is descripted, taking into account contributions arising from counting statistics, piling-up statistics of real detector pulse-height spectra and background fluctuations. The useful information is extracted from the net waveform area of the signal arising from the electric charge accumulated inside the detector tube. Improvement of detection limit is gained, therefore this detection system can be used in detection of low emission neutron pulsed sources with pulses of duration from nanoseconds to up. The application of the methodology to detection systems to be...

  1. Design of flattening filters for the fast-neutron beam at TAMVEC by use of decrement lines.

    Science.gov (United States)

    Otte, V A; Smathers, J B; Wright, R E

    1976-01-01

    Isodose distributions in a tissue-equivalent phantom produced by fast neutrons from 50-MeV deuterons incident on a thick beryllium target exhibit strong forward peaking, particularly for large fields. The design by use of decrement lines and the construction of polyethylene filters used to "flatten" those distributions are discussed and the results are illustrated. Also, the compromises of central-axis attenuation versus effective filter width and of off-axis peaking versus depth of "flattening" are discussed.

  2. Development of SiPM-based scintillator tile detectors for a multi-layer fast neutron tracker

    Directory of Open Access Journals (Sweden)

    Jakubek J.

    2012-10-01

    Full Text Available We are developing thin tile scintillator detectors with silicon photomultiplier (SiPM readout for use in a multi-layer fast-neutron tracker. The tracker is based on interleaved Timepix and plastic scintillator layers. The thin 15 × 15 × 2 mm plastic scintillators require suitable optical readout in order to detect and measure the energy lost by energetic protons that have been recoiled by fast neutrons. Our first prototype used dual SiPMs, coupled to opposite edges of the scintillator tile using light-guides. An alternative readout geometry was designed in an effort to increase the fraction of scintillation light detected by the SiPMs. The new prototype uses a larger SiPM array to cover the entire top face of the tile. This paper details the comparative performance of the two prototype designs. A deuterium-tritium (DT fast-neutron source was used to compare the relative light collection efficiency of the two designs. A collimated UV light source was scanned across the detector face to map the uniformity. The new prototype was found to have 9.5 times better light collection efficiency over the original design. Both prototypes exhibit spatial non-uniformity in their response. Methods of correcting this non-uniformity are discussed.

  3. Improvement of switching speed of a 600-V nonpunch through insulated gate bipolar transistor using fast neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Ha Ni; Sun, Gwang Min; Kim, Ji Suck; Hoang, Sy Minh Tuan; Jin, Mi Eun; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-02-15

    Fast neutron irradiation was used to improve the switching speed of a 600-V nonpunch-through insulated gate bipolar transistor. Fast neutron irradiation was carried out at 30-MeV energy in doses of 1 × 10{sup 8} n/cm{sup 2}, 1 × 10{sup 9} n/cm{sup 2}, 1 × 10{sup 10} n/cm{sup 2}, and 1 × 10{sup 11} n/cm{sup 2}. Electrical characteristics such as current–voltage, forward on-state voltage drop, and switching speed of the device were analyzed and compared with those prior to irradiation. The on-state voltage drop of the initial devices prior to irradiation was 2.08 V, which increased to 2.10 V, 2.20 V, 2.3 V, and 2.4 V, respectively, depending on the irradiation dose. This effect arises because of the lattice defects generated by the fast neutrons. In particular, the turnoff delay time was reduced to 92 nanoseconds, 45% of that prior to irradiation, which means there is a substantial improvement in the switching speed of the device.

  4. Different dose rate-dependent responses of human melanoma cells and fibroblasts to low dose fast neutrons.

    Science.gov (United States)

    Dionet, Claude; Müller-Barthélémy, Melanie; Marceau, Geoffroy; Denis, Jean-Marc; Averbeck, Dietrich; Gueulette, John; Sapin, Vincent; Pereira, Bruno; Tchirkov, Andrei; Chautard, Emmanuel; Verrelle, Pierre

    2016-09-01

    To analyze the dose rate influence in hyper-radiosensitivity (HRS) of human melanoma cells to very low doses of fast neutrons and to compare to the behaviour of normal human skin fibroblasts. We explored different neutron dose rates as well as possible implication of DNA double-strand breaks (DSB), apoptosis, and energy-provider adenosine-triphosphate (ATP) levels during HRS. HRS in melanoma cells appears only at a very low dose rate (VLDR), while a high dose rate (HDR) induces an initial cell-radioresistance (ICRR). HRS does not seem to be due either to DSB or to apoptosis. Both phenomena (HRS and ICRR) appear to be related to ATP availability for triggering cell repair. Fibroblast survival after neutron irradiation is also dose rate-dependent but without HRS. Melanoma cells or fibroblasts exert their own survival behaviour at very low doses of neutrons, suggesting that in some cases there is a differential between cancer and normal cells radiation responses. Only the survival of fibroblasts at HDR fits the linear no-threshold model. This new insight into human cell responses to very low doses of neutrons, concerns natural radiations, surroundings of accelerators, proton-therapy devices, flights at high altitude. Furthermore, ATP inhibitors could increase HRS during high-linear energy transfer (high-LET) irradiation.

  5. On the possible use of the MASURCA reactor as a flexible, high-intensity, fast neutron beam facility

    Science.gov (United States)

    Dioni, Luca; Jacqmin, Robert; Sumini, Marco; Stout, Brian

    2017-09-01

    In recent work [1, 2], we have shown that the MASURCA research reactor could be used to deliver a fairly-intense continuous fast neutron beam to an experimental room located next to the reactor core. As a consequence of the MASURCA favorable characteristics and diverse material inventories, the neutron beam intensity and spectrum can be further tailored to meet the users' needs, which could be of interest for several applications. Monte Carlo simulations have been performed to characterize in detail the extracted neutron (and photon) beam entering the experimental room. These numerical simulations were done for two different bare cores: A uranium metallic core (˜30% 235U enriched) and a plutonium oxide core (˜25% Pu fraction, ˜78% 239Pu). The results show that the distinctive resonance energy structures of the two core leakage spectra are preserved at the channel exit. As the experimental room is large enough to house a dedicated set of neutron spectrometry instruments, we have investigated several candidate neutron spectrum measurement techniques, which could be implemented to guarantee well-defined, repeatable beam conditions to users. Our investigation also includes considerations regarding the gamma rays in the beams.

  6. A study on the excore neutron flux monitoring system for the wide range measurement

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Jun; Jeong, Dae Won; Baek, Kwang Il; Lee, Jeong Yang; Ha, Jae Hong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-11-01

    This paper describes a study in which only one kind of neutron detector were used in the advanced ENFMS. The conceptual design was performed for overall system with unified fission chamber. The system consists of detector, junction box, wide-range amplifier and signal processing device. Also the requirements of 10CFR50 App. R were considered in design. On the other hand, through computer simulation, the characteristics of pulse-count mode and MSV mode was scrutinized and each noise withstanding capability was analyzed. The results say that 3rd moment has the more stable characteristics to background noise than MSV method. Also, to remain the integrity of information against noise, during installation and operation, the overall system of KSNP was analyzed from a view of noise. By administration for the cause of noise and noise-coupling paths, through the full understanding of noise characteristics, the transfer of the noise source can be minimized. (Author).

  7. Average Neutron Total Cross Sections in the Unresolved Energy Range From ORELA High Resolutio Transmission Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H

    2004-05-27

    Average values of the neutron total cross sections of {sup 233}U, {sup 235}U, {sup 238}U, and {sup 239}Pu have been obtained in the unresolved resonance energy range from high-resolution transmission measurements performed at ORELA in the past two decades. The cross sections were generated by correcting the effective total cross sections for the self-shielding effects due to the resonance structure of the data. The self-shielding factors were found by calculating the effective and true cross sections with the computer code SAMMY for the same Doppler and resolution conditions as for the transmission measurements, using an appropriate set of resonance parameters. Our results are compared to results of previous measurements and to the current ENDF/B-VI data.

  8. Neutron-19C scattering: Emergence of universal properties in a finite range potential

    Directory of Open Access Journals (Sweden)

    M.A. Shalchi

    2017-01-01

    Full Text Available The low-energy properties of the elastic s-wave scattering for the n-19C are studied near the critical condition for the occurrence of an excited Efimov state in n–n-18C. It is established to which extent the universal scaling laws, strictly valid in the zero-range limit, survive when finite range potentials are considered. By fixing the two-neutrons separation energy in 20C with available experimental data, it is studied the scaling of the real (δ0R and imaginary parts of the s-wave phase-shift with the variation of the n-18C binding energy. We obtain some universal characteristics given by the pole-position of kcot⁡(δ0R and effective-range parameters. By increasing the n-18C binding energy, it was verified that the excited state of 20C goes to a virtual state, resembling the neutron–deuteron behavior in the triton. It is confirmed that the analytical structure of the unitary cut is not affected by the range of the potential or mass asymmetry of the three-body system.

  9. Fast-Neutron Tomography using a Mobile Neutron Generator for Assessment of Steam-Water Distributions in Two-Phase Flows

    OpenAIRE

    Andersson, Peter

    2014-01-01

    This thesis describes the measurement technique of fast-neutron tomography for assessing spatial distributions of steam and water in two-phase flows. This so-called void distribution is of importance both for safe operation and for efficient use of the fuel in light water reactors, which compose the majority of the world’s commercial nuclear reactors. The technique is aimed for usage at thermal-hydraulic test loops, where heated two-phase flows are being investigated under reactor-relevant co...

  10. Measuring the Density of Different Materials by Using the Collimated Fast Neutron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Sudac, D.; Nad, K.; Orlic, Z.; Obhodas, J. [Rudjer Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia); Valkovic, V. [Rudjer Boskovic Institute, Zagreb (Croatia); Kvinticka 62, Zagreb (Croatia)

    2015-07-01

    It was demonstrated in the previous work that various threat materials could be detected inside the sea going cargo container by measuring the three variables, carbon and oxygen concentration and density of investigated material. Density was determined by measuring transmitted neutrons, which is not always practical in terms of setting up the instrument geometry. In order to enable more geometry flexibility, we have investigated the possibility of using the scattered neutrons in cargo material identification. For that purpose, the densities of different materials were measured depending on the position of neutron detectors and neutron generator with respect to the target position. One neutron detector was put above the target, one behind and one in front of the target, above the neutron generator. It was shown that all three positions of neutron detectors can be successfully used to measure the target density, but only if the detected neutrons are successfully discriminated from the gamma rays. Although the associated alpha particle technique/associate particle imaging (API) was used to discriminate the neutrons from the gamma rays, it is believed that the same results would be obtained by using the pulse shape discrimination method. In that way API technique can be avoided and the neutron generator which produces much higher beam intensity than 10{sup 8} n/s can be used. (authors)

  11. Production of fast neutrons from deuteron beams in view of producing radioactive heavy ions beams; Etude de la production de neutrons rapides a partir de faisceaux de deutons en vue de la mise en oeuvre de faisceaux d'ions lourds radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Pauwels, N

    2000-11-01

    This thesis is part of two research and development programmes for the study of neutron rich radioactive nuclear beam production. The technique is based on the ISOL method and can be summarized as follows. Fast neutrons are generated by the break-up of deuterons in a thick target. These neutrons irradiate a fissionable {sup 238}U target. The resulting fission products are extracted from the target, ionised, mass selected and post-accelerated. The aim of the thesis is to study the neutron angular and energetic distributions. After a bibliographical research to justify the choice of deuterons as the best projectile, we developed more specifically three points: - the extension of the activation detector method for neutron spectroscopy to a wide energy range (1 to 150 MeV), - the experimental measurement of neutron angular and energetic distributions produced by deuterons on thick targets. The deuteron energy ranges from 17 to 200 MeV and the thick targets were Be, C and U, - the realization of a code based on Serber's theory to predict the neutron distribution for any couple (deuteron energy-thick target). We conclude that for our application the most suitable target is C and the best deuteron energy is about 100 MeV. (author)

  12. MeV-range velocity-space tomography from gamma-ray and neutron emission spectrometry measurements at JET

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nocente, M.; Jacobsen, Asger Schou

    2017-01-01

    We demonstrate the measurement of a 2D MeV-range ion velocity distribution function by velocity-space tomography at JET. Deuterium ions were accelerated into the MeV-range by third harmonic ion cyclotron resonance heating. We made measurements with three neutron emission spectrometers and a high-...

  13. Impaired Fasting Glucose in Nondiabetic Range: Is It a Marker of Cardiovascular Risk Factor Clustering?

    Science.gov (United States)

    Valentino, Giovanna; Kramer, Verónica; Orellana, Lorena; Bustamante, María José; Casasbellas, Cinthia; Adasme, Marcela; Salazar, Alejandra; Navarrete, Carlos; Acevedo, Mónica

    2015-01-01

    Background. Impaired fasting glucose (IFG) through the nondiabetic range (100–125 mg/dL) is not considered in the cardiovascular (CV) risk profile. Aim. To compare the clustering of CV risk factors (RFs) in nondiabetic subjects with normal fasting glucose (NFG) and IFG. Material and Methods. Cross-sectional study in 3739 nondiabetic subjects. Demographics, medical history, and CV risk factors were collected and lipid profile, fasting glucose levels (FBG), C-reactive protein (hsCRP), blood pressure (BP), anthropometric measurements, and aerobic capacity were determined. Results. 559 (15%) subjects had IFG: they had a higher mean age, BMI, waist circumference, non-HDL cholesterol, BP, and hsCRP (p < 0.0001) and lower HDL (p < 0.001) and aerobic capacity (p < 0.001). They also had a higher prevalence of hypertension (34% versus 25%; p < 0.001), dyslipidemia (79% versus 74%; p < 0.001), and obesity (29% versus 16%; p < 0.001) and a higher Framingham risk score (8% versus 6%; p < 0.001). The probability of presenting 3 or more CV RFs adjusted by age and gender was significantly higher in the top quintile of fasting glucose (≥98 mg/dL; OR = 2.02; 1.62–2.51). Conclusions. IFG in the nondiabetic range is associated with increased cardiovascular RF clustering. PMID:26504260

  14. Impaired Fasting Glucose in Nondiabetic Range: Is It a Marker of Cardiovascular Risk Factor Clustering?

    Directory of Open Access Journals (Sweden)

    Giovanna Valentino

    2015-01-01

    Full Text Available Background. Impaired fasting glucose (IFG through the nondiabetic range (100–125 mg/dL is not considered in the cardiovascular (CV risk profile. Aim. To compare the clustering of CV risk factors (RFs in nondiabetic subjects with normal fasting glucose (NFG and IFG. Material and Methods. Cross-sectional study in 3739 nondiabetic subjects. Demographics, medical history, and CV risk factors were collected and lipid profile, fasting glucose levels (FBG, C-reactive protein (hsCRP, blood pressure (BP, anthropometric measurements, and aerobic capacity were determined. Results. 559 (15% subjects had IFG: they had a higher mean age, BMI, waist circumference, non-HDL cholesterol, BP, and hsCRP (p<0.0001 and lower HDL (p<0.001 and aerobic capacity (p<0.001. They also had a higher prevalence of hypertension (34% versus 25%; p<0.001, dyslipidemia (79% versus 74%; p<0.001, and obesity (29% versus 16%; p<0.001 and a higher Framingham risk score (8% versus 6%; p<0.001. The probability of presenting 3 or more CV RFs adjusted by age and gender was significantly higher in the top quintile of fasting glucose (≥98 mg/dL; OR = 2.02; 1.62–2.51. Conclusions. IFG in the nondiabetic range is associated with increased cardiovascular RF clustering.

  15. Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Roeder, M.; Cowan, T.E.; Kempe, M.; Yakorev, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universitaet Dresden, Dresden (Germany); Elekes, Z. [MTA ATOMKI, Debrecen (Hungary); Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Aumann, T.; Caesar, C. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt, Darmstadt (Germany); Bemmerer, D.; Sobiella, M.; Stach, D.; Wagner, A. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Boretzky, K.; Hehner, J.; Heil, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Maroussov, V. [Universitaet zu Koeln, Koeln (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Nusair, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Al-Balqa Applied University, Salt (Jordan); Prokofiev, A.V. [Uppsala University, The Svedberg Laboratory, Uppsala (Sweden); Reifarth, R. [Johann Wolfgang Goethe - Universitaet, Frankfurt am Main (Germany); Zilges, A. [Universitaet zu Koeln, Koeln (Germany); Zuber, K. [Technische Universitaet Dresden, Dresden (Germany); Collaboration: R3B Collaboration

    2014-07-15

    Composite detectors made of stainless-steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175 MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment. (orig.)

  16. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a

  17. Enhancement of critical current density in fast neutron irradiated melt-textured YBa[sub 2]Cu[sub 3]O[sub 7-x

    Energy Technology Data Exchange (ETDEWEB)

    Puzniak, R.; Wisniewski, A.; Baran, M.; Szymczak, H. (Polska Akademia Nauk, Warsaw (Poland). Inst. Fizyki); Zhang Pingxiang; Wang Jingrong; Zhou Lian (Northwest Inst. for Nonferrous Metal Research, Baoji, SN (China)); Pytel, K.; Pytel, B. (Institute of Atomic Energy, Otwock-Swierk (Poland))

    1993-01-01

    The critical current density in melt-textured samples of YBa[sub 2]Cu[sub 3]O[sub 7]-x obtained by the powder melting process was determined from magnetization measurements. A linear dependence between the width of the hysteresis loop and sample size was observed for both unirradiated and irradiated samples. This indicates that the critical current is circulating through the whole sample and is not disconnected by weak links, even when a magnetic field is applied in the irradiated sample. After fast neutron irradiation with fluences form 5 x 10[sup 16] to 6 x 10[sup 17] n cm[sup -2] (E > 0.5 MeV), significant enhancement of the critical current density, j[sub c], was observed. Critical current density, determined from magnetization measurements, for magnetic field perpendicular to the a-b plane j[sub c][sup ab], reaches [approx] 10[sup 5] A cm[sup -2] at 77 K in 1 T. For H parallel to the a-b plane, j[sub c][sup c] along the c-axis reaches 5 x 10[sup 3] A cm[sup -2]. An increase in the anisotropy of the critical current was observed after fast neutron irradiation in the temperature range 60-80 K. (Author).

  18. Gauged B - L number and neutron-antineutron oscillation: long-range forces mediated by baryophotons

    Energy Technology Data Exchange (ETDEWEB)

    Addazi, Andrea; Berezhiani, Zurab [Universita dell' Aquila, Dipartimento delle Scienze Fisiche e Chimiche, L' Aquila (Italy); INFN, Laboratori Nazionali Gran Sasso, L' Aquila (Italy); Kamyshkov, Yuri [University of Tennessee, Department of Physics, Knoxville, TN (United States)

    2017-05-15

    Transformation of a neutron to an antineutron n → n has not yet been experimentally observed. In principle, it can occur with free neutrons in the vacuum or with neutrons bound inside the nuclei. In a nuclear medium the neutron and the antineutron have different potentials and for that reason n-n conversion in nuclei is heavily suppressed. This transformation can also be suppressed for free neutrons in the presence of an environmental vector field that distinguishes the neutron from the antineutron. We consider the case of a gauge field coupled to the B - L charge of the particles (B - L photon), and we show that discovery of n-n oscillation in experiment will lead to few order of magnitudes stronger limits on its coupling constant than present limits from the tests of the equivalence principle. If n-n oscillation will be discovered via nuclear instability, but not in free neutron oscillations at a corresponding level, this would indicate the presence of such environmental fifth forces. In the latter case the B - L potential can be measurable by varying the external magnetic field for achieving the resonance conditions for n-n conversion. As for neutron-mirror neutron oscillation, such potentials should have no effect once the fifth forces are associated to a common quantum number (B - L)-(B{sup '} - L{sup '}) shared by the ordinary and mirror particles. (orig.)

  19. In-Pile Experiment of a New Hafnium Aluminide Composite Material to Enable Fast Neutron Testing in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Donna Post Guillen; Douglas L. Porter; James R. Parry; Heng Ban

    2010-06-01

    A new hafnium aluminide composite material is being developed as a key component in a Boosted Fast Flux Loop (BFFL) system designed to provide fast neutron flux test capability in the Advanced Test Reactor. An absorber block comprised of hafnium aluminide (Al3Hf) particles (~23% by volume) dispersed in an aluminum matrix can absorb thermal neutrons and transfer heat from the experiment to pressurized water cooling channels. However, the thermophysical properties, such as thermal conductivity, of this material and the effect of irradiation are not known. This paper describes the design of an in-pile experiment to obtain such data to enable design and optimization of the BFFL neutron filter.

  20. Design and initial 1D radiography tests of the FANTOM mobile fast-neutron radiography and tomography system

    Science.gov (United States)

    Andersson, P.; Valldor-Blücher, J.; Andersson Sundén, E.; Sjöstrand, H.; Jacobsson-Svärd, S.

    2014-08-01

    The FANTOM system is a tabletop sized fast-neutron radiography and tomography system newly developed at the Applied Nuclear Physics Division of Uppsala University. The main purpose of the system is to provide time-averaged steam-and-water distribution measurement capability inside the metallic structures of two-phase test loops for light water reactor thermal-hydraulic studies using a portable fusion neutron generator. The FANTOM system provides a set of 1D neutron transmission data, which may be inserted into tomographic reconstruction algorithms to achieve a 2D mapping of the steam-and-water distribution. In this paper, the selected design of FANTOM is described and motivated. The detector concept is based on plastic scintillator elements, separated for spatial resolution. Analysis of pulse heights on an event-to-event basis is used for energy discrimination. Although the concept allows for close stacking of a large number of detector elements, this demonstrator is equipped with only three elements in the detector and one additional element for monitoring the yield from the neutron generator. The first measured projections on test objects of known configurations are presented. These were collected using a Sodern Genie 16 neutron generator with an isotropic yield of about 1E8 neutrons per second, and allowed for characterization of the instrument's capabilities. At an energy threshold of 10 MeV, the detector offered a count rate of about 500 cps per detector element. The performance in terms of spatial resolution was validated by fitting a Gaussian Line Spread Function to the experimental data, a procedure that revealed a spatial unsharpness in good agreement with the predicted FWHM of 0.5 mm.

  1. Timing and position response of a block detector for fast neutron time-of-flight imaging

    Science.gov (United States)

    Laubach, M. A.; Hayward, J. P.; Zhang, X.; Cates, J. W.

    2014-11-01

    Our research effort seeks to improve the spatial and timing performance of a block detector made of a pixilated plastic scintillator (EJ-200), first demonstrated as part of Oak Ridge National Laboratory's Advanced Portable Neutron Imaging System. Improvement of the position and time response is necessary to achieve better resolution and contrast in the images of shielded special nuclear material. Time-of-flight is used to differentiate between gamma and different sources of neutrons (e.g., transmission and fission neutrons). Factors limiting the timing and position performance of the neutron detector have been revealed through simulations and measurements. Simulations have suggested that the degradation in the ability to resolve pixels in the neutron detector is due to those interactions occurring near the light guide. The energy deposition within the neutron detector is shown to affect position performance and imaging efficiency. This examination details how energy cuts improve the position performance and degrade the imaging efficiency. Measurements have shown the neutron detector to have a timing resolution of σ=238 ps. The majority of this timing uncertainty is from the depth-of-interaction (DOI) of the neutron which is confirmed by simulations and analytical calculations.

  2. Experience with fast neutron therapy for unresectable carcinoma of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Al-Abdulla, A.S.M. (Univ. of Texas Medical Branch, Galveston); Hussey, D.H.; Olson, M.H.; Wright, A.E.

    1981-02-01

    The records of 70 patients with adenocarcinoma of the pancreas treated with radiotherapy were reviewed. Fifteen were treated with 50-MeV/sub d ..-->.. Be/ neutrons or a combination of 50-MeV/sub d ..-->.. Be/ neutrons and 25 to 32 MeV photons (neutron group), 30 with external beam photons alone (photon group), and 25 with radioactive gold-grain implantation (/sup 198/Au-implant group). The 12-month survival rate was 40% (6/15) for the neutron group; three patients in this group were living at the time of analysis, 16, 19, and 42 months from the date of diagnosis. By comparison, the 12-month survival rate was 23% (7/30) for the photon group and 32% (8/25) or the /sup 198/Au-implant group. The actuarial survival curve for the neutron group was significantly better than the survival curve for the photon group (Wilcoxon test/sup 7/: p = 0.3). Although the difference between the survival curves for the neutron and /sup 198/Au-implant groups is not statistically significant, the neutron patients presented more advanced disease than those treated with radioactive gold-grain implants. No radiotherapy complications were observed in the neutron group, whereas 3% (1/30) of patients in the photon group and 24% (6/25) of patients in the /sup 198/Au-implant group developed major complications.

  3. Optimization of the Army’s Fast Neutron Moderator for Radiography

    Science.gov (United States)

    2013-02-26

    TECHNOLOGY DEVELOPMENTS 13 PNL Generator / Moderator Design 13 CONCLUSIONS 15 REFERENCES 16 LIST OF SYMBOLS, ABBREVIATIONS...and x-ray image 12 Figure 6: Second half comparison of neutron, processed, and x-ray image 13 Figure 7: The initial setup of the PNL neutron...reactor facility; for example, muntions and weapon systems that contain energetic materials. TECHNOLOGY DEVELOPMENTS: PNL Generator / Moderator

  4. Study of fast neutron scattering. The displacement cross-section (1962); Etude de la diffusion des neutrons rapides. Section efficace de deplacement (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Millot, J.P. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1962-07-01

    We propose a method for calculating the biological efficiency of fast neutrons emitted by in-pile fission sources. This method justifies the empirical theory of Albert and Welton. In making simple assumptions concerning the cross-sections, we have supposed that the propagation can ben reduced to a mono-kinetic problem. A system of orthonormal functions is then set up making it possible to calculate the flux leaving a planar source. This method generalises the results obtained by Platzek to the case where the elastic cross-sections are not isotropic, and make it possible in particular to define a displacement cross-section: extension of the diffusion coefficient. This method can be generalised to the case of neutron diffraction as a function of time, and to the study of slowing-down. Numerical results are given in an appendix for the following: H{sub 2}O, D{sub 2}O, Fe, Be, Pb, CH, CH{sub 2}. These cross-sections have been verified experimentally in water and in graphite for neutrons of 2.5 and 14 MeV using a SAMES accelerator and a 2 MeV Van De Graaff. (author) [French] Nous proposons une methode permettant de calculer l'efficacite biologique des neutrons rapides issus des sources de fission dans la protection d'une pile. Cette methode justifie la theorie empirique d'Albert et Welton. En faisant des hypotheses simples sur les sections efficaces, nous avons suppose que la propagation pouvait etre ramenee a un probleme monocinetique. Nous construisons alors un systeme de fonctions orthonormales qui permet de calculer le flux issu d'une source plane. Cette methode generalise les resultats obtenus par Platzek au cas ou les sections efficaces elastiques ne sont pas isotropes et en particulier permet de definir une section efficace de deplacement: extension du coefficient de diffusion. Cette methode peut etre generalisee a la diffusion des neutrons en fonction du temps et a l'etude du ralentissement. Les resultats numeriques sont donnes en annexe

  5. Disclosure of the oscillations in kinetics of the reactor pressure vessel steel damage at fast neutron intensity decreasing

    Science.gov (United States)

    Krasikov, E.; Nikolaenko, V.

    2017-01-01

    Fast neutron intensity influence on reactor materials radiation damage is a critically important question in the problem of the correct use of the accelerated irradiation tests data for substantiation of the materials workability in real irradiation conditions that is low neutron intensity. Investigations of the fast neutron intensity (flux) influence on radiation damage and experimental data scattering reveal the existence of non-monotonous sections in kinetics of the reactor pressure vessels (RPV) steel damage. Discovery of the oscillations as indicator of the self-organization processes presence give reasons for new ways searching on reactor pressure vessel (RPV) steel radiation stability increasing and attempt of the self-restoring metal elaboration. Revealing of the wavelike process in the form of non monotonous parts of the kinetics of radiation embrittlement testifies that periodic transformation of the structure take place. This fact actualizes the problem of more precise definition of the RPV materials radiation embrittlement mechanisms and gives reasons for search of the ways to manage the radiation stability (nanostructuring and so on to stimulate the radiation defects annihilation), development of the means for creating of more stableness self recovering smart materials.

  6. Detection of fast neutrons from D-T nuclear reaction using a 4H-SiC radiation detector

    Science.gov (United States)

    Zatko, Bohumir; Sagatova, Andrea; Sedlackova, Katarina; Necas, Vladimir; Dubecky, Frantisek; Solar, Michael; Granja, Carlos

    2016-09-01

    The particle detector based on a high purity epitaxial layer of 4H-SiC exhibits promising properties in detection of various types of ionizing radiation. Due to the wide band gap of 4H-SiC semiconductor material, the detector can reliably operate at room and also elevated temperatures. In this work we focused on detection of fast neutrons generated the by D-T (deuterium-tritium) nuclear reaction. The epitaxial layer with a thickness of 105 μm was used as a detection part. A circular Schottky contact of a Au/Ni double layer was evaporated on both sides of the detector material. The detector structure was characterized by current-voltage and capacitance-voltage measurements, at first. The results show very low current density (SiC detector is caused by the elastic and inelastic scattering on the silicon or carbide component of the detector material. Another possibility that increases the detection efficiency is the use of a conversion layer. In our measurements, we glued a HDPE (high density polyethylene) conversion layer on the detector Schottky contact to transform fast neutrons to protons. Hydrogen atoms contained in the conversion layer have a high probability of interaction with neutrons through elastic scattering. Secondary generated protons flying to the detector can be easily detected. The detection properties of detectors with and without the HDPE conversion layer were compared.

  7. Radiation induced changes in electrical conductivity of chemical vapor deposited silicon carbides under fast neutron and gamma-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Bun, E-mail: btsuchiya@meijo-u.ac.jp [Department of General Education, Faculty of Science and Technology, Meijo University, 1-501, Shiogamaguchi, Tempaku-ku, Nagoya 468-8502 (Japan); Shikama, Tatsuo; Nagata, Shinji; Saito, Kesami [Institute for Materials Research, Tohoku University, 2-1-1, Katahira, Aoba-ku, Sendai 980-8577 (Japan); Yamamoto, Syunya [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233, Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Ohnishi, Seiki [Tokai Research and Development Center, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Nozawa, Takashi [Aomori Research and Development Center, Japan Atomic Energy Agency, 2-166, Omotedate, Obuchi, Rokkasho, Aomori 039-3212 (Japan)

    2011-10-15

    The radiation-induced changes in the volume electrical conductivities of chemical vapor deposited silicon carbides (CVD-SiCs) were in-site investigated by performing irradiation using 1.17 and 1.33-MeV gamma-ray and 14-MeV fast neutron beams in air and vacuum. Under gamma-ray irradiation at ionization dose rates of 3.6 and 5.9 Gy/s and irradiation temperature of approximately 300 K, the initial rapid increase in electrical conductivity; this is indicative of radiation-induced conductivity (RIC), occurred due to electronic excitation, and a more gradual increase followed up to a dose of approximately 10-50 kGy corresponding to the results in base conductivity without radiation; this is indicative of radiation-induced electrical degradation (RIED). However, the radiation-induced phenomena were not observed at irradiation temperatures above 373 K. Under neutron irradiation at a further low dose rate below approximately 2.1 Gy/s, a fast neutron flux of 9.2 x 10{sup 14} n/m{sup 2} s, and 300 K, the RIED-like behavior according to radiation-induced modification of the electrical property occurred with essentially no displacement damage, but ionizing effects (radiolysis).

  8. Measurements of fast neutron-induced fission data of Np-237

    Energy Technology Data Exchange (ETDEWEB)

    Win, Than; Saito, Keiichiro; Baba, Mamoru; Iwasaki, Tomohiko; Ibaraki, Masanobu; Miura, Takako; Sanami, Toshiya; Nauchi, Yasushi; Hirakawa, Naohiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1998-03-01

    We have performed the following measurements for {sup 237}Np using the 4.5 MV Dynamitron accelerator of Tohoku University as the pulsed neutron source: (1) Prompt fission neutron spectrum for 0.62 MeV incident neutrons, and (2) Neutron-Induced fission cross-section between 10 and 100 keV. The prompt fission neutron spectrum was measured using TOF method with a heavily shielded NE213 scintillation detector. The Maxwellian temperature T{sub m} derived is 1.28 MeV, which is lower than that of 1.38 MeV in JENDL-3.2. The fission cross sections were measured between 10 - 100 keV. The results are between JENDL-3.2 and ENDF/B-VI. (author)

  9. KWS-2, the high intensity / wide Q-range small-angle neutron diffractometer for soft-matter and biology at FRM II

    Science.gov (United States)

    Radulescu, A.; Pipich, V.; Frielinghaus, H.; Appavou, M.-S.

    2012-03-01

    The KWS-2 small-angle neutron diffractometer operated by JCNS at FRM II is upgraded and optimized towards high intensity and wide Q-range studies of mesoscopic structures and structural changes due to rapid kinetics and becomes a dedicated SANS instrument to soft-matter and biology. The high intensity permits fast measurement of small or weak scattering samples and time resolved structural studies with a time resolution up to 100ms. The possibility to cover up to four decades in Q will soon enable structural investigation over a wide length scale, between several Å and lμm. The characteristics and performance of the instrument in the conventional pinhole mode is detailed presented and the new upgrades currently in progress and aiming for boosting the instrument performance towards higher intensity and wider Q-range are reported.

  10. Fast methods for long-range interactions in complex systems. Lecture notes

    Energy Technology Data Exchange (ETDEWEB)

    Sutmann, Godehard; Gibbon, Paul; Lippert, Thomas (eds.)

    2011-10-13

    Parallel computing and computer simulations of complex particle systems including charges have an ever increasing impact in a broad range of fields in the physical sciences, e.g. in astrophysics, statistical physics, plasma physics, material sciences, physical chemistry, and biophysics. The present summer school, funded by the German Heraeus-Foundation, took place at the Juelich Supercomputing Centre from 6 - 10 September 2010. The focus was on providing an introduction and overview over different methods, algorithms and new trends for the computational treatment of long-range interactions in particle systems. The Lecture Notes contain an introduction into particle simulation, as well as five different fast methods, i.e. the Fast Multipole Method, Barnes-Hut Tree Method, Multigrid, FFT based methods, and Fast Summation using the non-equidistant FFT. In addition to introducing the methods, efficient parallelization of the methods is presented in detail. This publication was edited at the Juelich Supercomputing Centre (JSC) which is an integral part of the Institute for Advanced Simulation (IAS). The IAS combines the Juelich simulation sciences and the supercomputer facility in one organizational unit. It includes those parts of the scientific institutes at Forschungszentrum Juelich which use simulation on supercomputers as their main research methodology. (orig.)

  11. Broad iron line in the fast spinning neutron-star system system 4U 1636-53

    NARCIS (Netherlands)

    Sanna, Andrea; Hiemstra, Beike; M´endez, Mariano; Altamirano, Diego; Belloni, Tomaso; Linares, Manuel

    2013-01-01

    We analysed the X-ray spectra of six observations, simultaneously taken with XMMNewton and Rossi X-ray Timing Explorer (RXTE), of the neutron star low-mass X-ray binary 4U 1636–53. The observations cover several states of the source, and therefore a large range of inferred mass accretion rate. These

  12. Measurements of response functions of EJ-299-33A plastic scintillator for fast neutrons

    Science.gov (United States)

    Hartman, J.; Barzilov, A.; Peters, E. E.; Yates, S. W.

    2015-12-01

    Monoenergetic neutron response functions were measured for an EJ-299-33A plastic scintillator. The 7-MV Van de Graaff accelerator at the University of Kentucky Accelerator Laboratory was used to produce proton and deuteron beams for reactions with gaseous tritium and deuterium targets, yielding monoenergetic neutrons by means of the 3H(p,n)3He, 2H(d,n)3He, and 3H(d,n)4He reactions. The neutron energy was selected by tuning the charged-particle's energy and using the angular dependence of the neutron emission. The resulting response functions were measured for 0.1-MeV steps in neutron energy from 0.1 MeV to 8.2 MeV and from 12.2 MeV to 20.2 MeV. Experimental data were processed using a procedure for digital pulse-shape discrimination, which allowed characterization of the response functions of the plastic scintillator to neutrons only. The response functions are intended for use in neutron spectrum unfolding methods.

  13. Magnetization studies of YBa/sub 2/Cu/sub 3/Osub(7-x) irradiated by fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, A.; Baran, M.; Przyslupski, P.; Szymczak, H.; Pajaczkowska, A.; Pytel, B.; Pytel, K.

    1988-02-01

    Studies of the effect of fast neutron damage on the magnetic hysteresis of YBa/sub 2/Cu/sub 3/Osub(7-x) ceramic samples subjected to fluence of neutrons of 2x10/sup 16/ n/cm/sup 2/ up to 6x10/sup 17/ n/cm/sup 2/ have been performed. Irradiation up to dose of 1x10/sup 17/ did not cause any change in the critical temperature. However it causes a strong increase of the magnetic hysteresis which is presumably connected with the creation of defects. The critical current density at 77 K in H = 10 KOe for the sample irradiated with the dose 1x10/sup 17/ n/cm/sup 2/ was estimated to be 520 A/cm/sup 2/ as compared to 29 A/cm/sup 2/ for the reference non-irradiated sample.

  14. Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography

    CERN Document Server

    Vartsky, D; Dangendorf, V; Israelashvili, I; Mor, I; Bar, D; Tittelmeier, K; Weierganz, M; Breskin, A

    2016-01-01

    A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.

  15. BioRef II—Neutron reflectometry with relaxed resolution for fast, kinetic measurements at HZB

    Science.gov (United States)

    Trapp, M.; Steitz, R.; Kreuzer, M.; Strobl, M.; Rose, M.; Dahint, R.

    2016-10-01

    We present an upgrade to the time-of-flight neutron reflectometer BioRef at the research reactor BER II of the Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). Through the integration of an additional chopper into the existing setup, the available wavelength resolution is significantly extended. Now two distinct operation modes can be used: a high resolution mode with Δλ/λ ranging from 1% to 5%, which allows for the investigation of thick films up to 4000 Å, and a high flux mode with Δλ/λ = 7%-11%. In the high flux mode, reflectivity curves from 0.007 Å-1 to 0.2 Å-1 with three angular settings can be recorded in 7 min. For a single angular setting and its respective window in Q-space, a time resolution of even less than 4 min is reached. The different configurations are documented by respective measurements (a) on a Ni-Ti multilayer and (b) the swelling kinetics of a solid-supported phospholipid coating upon incubation in a polyelectrolyte solution.

  16. Response measurement of single-crystal chemical vapor deposition diamond radiation detector for intense X-rays aiming at neutron bang-time and neutron burn-history measurement on an inertial confinement fusion with fast ignition

    Energy Technology Data Exchange (ETDEWEB)

    Shimaoka, T., E-mail: t.shimaoka@eng.hokudai.ac.jp; Kaneko, J. H.; Tsubota, M. [Graduate School of Engineering, Hokkaido University, Sapporo 060-8628 (Japan); Arikawa, Y.; Nagai, T.; Kojima, S.; Abe, Y.; Sakata, S.; Fujioka, S.; Nakai, M.; Shiraga, H.; Azechi, H. [Osaka University, 2-6 Yamada-Oka, Suita, Osaka 565-0871 (Japan); Isobe, M. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Sato, Y. [The Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Chayahara, A.; Umezawa, H.; Shikata, S. [Diamond Research Laboratory, National Institute of Advanced Industrial Science and Technology (AIST), 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)

    2015-05-15

    A neutron bang time and burn history monitor in inertial confinement fusion with fast ignition are necessary for plasma diagnostics. In the FIREX project, however, no detector attained those capabilities because high-intensity X-rays accompanied fast electrons used for plasma heating. To solve this problem, single-crystal CVD diamond was grown and fabricated into a radiation detector. The detector, which had excellent charge transportation property, was tested to obtain a response function for intense X-rays. The applicability for neutron bang time and burn history monitor was verified experimentally. Charge collection efficiency of 99.5% ± 0.8% and 97.1% ± 1.4% for holes and electrons were obtained using 5.486 MeV alpha particles. The drift velocity at electric field which saturates charge collection efficiency was 1.1 ± 0.4 × 10{sup 7} cm/s and 1.0 ± 0.3 × 10{sup 7} cm/s for holes and electrons. Fast response of several ns pulse width for intense X-ray was obtained at the GEKKO XII experiment, which is sufficiently fast for ToF measurements to obtain a neutron signal separately from X-rays. Based on these results, we confirmed that the single-crystal CVD diamond detector obtained neutron signal with good S/N under ion temperature 0.5–1 keV and neutron yield of more than 10{sup 9} neutrons/shot.

  17. New modelling method for fast reactor neutronic behaviours analysis; Nouvelles methodes de modelisation neutronique des reacteurs rapides de quatrieme Generation

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, P.

    2011-05-23

    Due to safety rules running on fourth generation reactors' core development, neutronics simulation tools have to be as accurate as never before. First part of this report enumerates every step of fast reactor's neutronics simulation implemented in current reference code: ECCO. Considering the field of fast reactors that meet criteria of fourth generation, ability of models to describe self-shielding phenomenon, to simulate neutrons leakage in a lattice of fuel assemblies and to produce representative macroscopic sections is evaluated. The second part of this thesis is dedicated to the simulation of fast reactors' core with steel reflector. These require the development of advanced methods of condensation and homogenization. Several methods are proposed and compared on a typical case: the ZONA2B core of MASURCA reactor. (author) [French] Les criteres de surete qui regissent le developpement de coeurs de reacteurs de quatrieme generation implique l'usage d'outils de calcul neutronique performants. Une premiere partie de la these reprend toutes les etapes de modelisation neutronique des reacteurs rapides actuellement d'usage dans le code de reference ECCO. La capacite des modeles a decrire le phenomene d'autoprotection, a representer les fuites neutroniques au niveau d'un reseau d'assemblages combustibles et a generer des sections macroscopiques representatives est appreciee sur le domaine des reacteurs rapides innovants respectant les criteres de quatrieme generation. La deuxieme partie de ce memoire se consacre a la modelisation des coeurs rapides avec reflecteur acier. Ces derniers necessitent le developpement de methodes avancees de condensation et d'homogenisation. Plusieurs methodes sont proposees et confrontees sur un probleme de modelisation typique: le coeur ZONA2B du reacteur maquette MASURCA

  18. Standard Practice for Application and Analysis of Nuclear Research Emulsions for Fast Neutron Dosimetry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 Nuclear Research Emulsions (NRE) have a long and illustrious history of applications in the physical sciences, earth sciences and biological sciences (1,2) . In the physical sciences, NRE experiments have led to many fundamental discoveries in such diverse disciplines as nuclear physics, cosmic ray physics and high energy physics. In the applied physical sciences, NRE have been used in neutron physics experiments in both fission and fusion reactor environments (3-6). Numerous NRE neutron experiments can be found in other applied disciplines, such as nuclear engineering, environmental monitoring and health physics. Given the breadth of NRE applications, there exist many textbooks and handbooks that provide considerable detail on the techniques used in the NRE method. As a consequence, this practice will be restricted to the application of the NRE method for neutron measurements in reactor physics and nuclear engineering with particular emphasis on neutron dosimetry in benchmark fields (see Matrix E706). 1...

  19. Neutron Flux Measurement at TAPIRO Fast Reactor for APD's Irradiation Fluence Evaluation

    CERN Document Server

    Angelone, M; Diemoz, Marcella; Festinesi, Armando; Longo, Egidio; Organtini, Giovanni; Rosi, G

    1998-01-01

    The Avalanche Photodiodes ( APD) were chosen as photon sensors for the region of the CMS electromagnetic calorimeter. The LHC will be a hard environment for what concerns the radiation levels in the detectors. The most relevant damage on APDs is caused by neutrons that produce an increase in the dark current of these devices. In the CMS-ECAL collaboration a big effort was indeed done to understand this damage, but the evaluation of the absolute effect was limited by the knowledge of the neutron flux calibration of the various irradiation facilities. This investigation describes the calibration of the neutron flux of the Tapiro reactor in Rome and the calculation of the Non-Ionizing-Energy-Loss on Silicon for this reactor. The damage parameter alpha for the APDs is evaluated to be about 10-11*10^-17 A/cm/neutron at 18C and 2 days after the irradiation. Some cross-checks with other irradiation facilities are also presented.

  20. Anharmonic effects in neutron cross-section calculation for nuclei in mass range 48 [<=] A [<=] 58

    Energy Technology Data Exchange (ETDEWEB)

    Lubian, J.; Cabezas, R. (Center for Applied Studies to Nuclear Development, Havana (Cuba))

    1993-08-01

    In this paper, a deviation of the target nucleus wavefunction from the harmonic vibrator in the neutron scattering process by medium-mass nuclei at low energies is studied. Two forms of anharmonicities are used: anharmonicities due to the higher-order terms in the Hamiltonians and those due to the different deformation parameters, corresponding to transitions between nuclear states. For calculation of neutron cross sections, combined use of the coupled-channel method and the statistical Hauser-Feshbach-Moldauer theory is applied. It is shown that both kinds of anharmonicities introduced a correction (about 10% in some cases) to the neutron cross sections at low energies. (author).

  1. Gamma-rays and fast neutron responses calculations for personal electronic dosimetry purpose

    Science.gov (United States)

    Jung, M.; Teissier, C.; Siffert, P.

    2001-02-01

    Real-time dosimeters with small size N-type silicon diodes are proposed here for low-dose rate controls. Numerical simulations are used to predict the responses of various associated filters, neutron converters and sensors. The monitor is foreseen to work as a counter with acceptance cut-offs set on each individual pulse height. Discussions are undertaken against the minimal outline necessary to reach convenient measurement accuracies in unknown gamma-neutron fields.

  2. An unadjusted 25 group neutron cross section set for fast reactor core calculations from JENDL-2 library

    Energy Technology Data Exchange (ETDEWEB)

    Devan, K.; Gopalakrishnan, V.; Lee, S.M. [Nuclear Data Section Indira Ganhi Centre for Atomic Research, Tamilnadu (India)

    1994-12-31

    We have created a 25 group neutron cross section set (IGCJENDL) for nuclides of interest to LMFBRs from the Japanese Evaluated Nuclear Data Library - Version 2 (JENDL-2) in the format of French adjusted Cadarache Version 2 set (1969). The integral validation of IGCJENDL set was done by analyzing nine fast critical assemblies proposed by Cross Section Evaluation Working Group (CSEWG). The calculated integral parameters agreed reasonably well with the reported measured values. It is found that this set predicts the integral parameters, k-eff in particular, close to that predicted by adjusted CARNAVAL IV (French) or BNAB-78 (Russian) sets, for a 1200 MWe theoretical benchmark, representing a large power reactor.

  3. High-precision investigations of the fast range imaging camera SwissRanger

    Science.gov (United States)

    Kahlmann, T.; Ingensand, H.

    2007-09-01

    Many applications need fast measurement systems that capture their environment in three dimensions. Adequate measurement sensors are required that provide fast, accurate, and reliable 3-D data. Automotive applications long for real time and reliable data, not only for driving assistance systems but for safety, also. Until now, most solutions, like multi image photogrammetry, radar sensors or laser scanners, lack in one of these aspects at least. With the upcoming range imaging cameras, new sensors with a performance never seen before are to be taken into consideration. Range imaging has already been proved as an emerging technology for automotive applications. These cameras provide a distance measurement system in each pixel and therefore produce 3-D data with up to video frame rates with a single sensor. But because of their new measurement concept classical calibration approaches cannot be used. This paper will present results of research about the calibration of the SwissRanger TM, a range imaging camera introduced by CSEM Switzerland. Special emphasis is given to the determination of the influence of the diverse parameters on the distance measurement accuracy. These parameters are the temperature, the reflectivity and the distance itself, for example. The influences are represented in functional dependencies in order to reach high accuracy of the system. Temperature compensation by means of a specialized setup is addressed. A successful implementation of a temperature drift compensation by means of a differential setup is presented.

  4. Fasting Cycles Retard Growth of Tumors and Sensitize a Range of Cancer Cell Types to Chemotherapy

    Science.gov (United States)

    Lee, Changhan; Raffaghello, Lizzia; Brandhorst, Sebastian; Safdie, Fernando M.; Bianchi, Giovanna; Martin-Montalvo, Alejandro; Pistoia, Vito; Wei, Min; Hwang, Saewon; Merlino, Annalisa; Emionite, Laura; de Cabo, Rafael; Longo, Valter D.

    2013-01-01

    Short-term starvation (or fasting) protects normal cells, mice, and potentially humans from the harmful side effects of a variety of chemotherapy drugs. Here, we show that treatment with starvation conditions sensitized yeast cells (Saccharomyces cerevisiae) expressing the oncogene-like RAS2val19 to oxidative stress and 15 of 17 mammalian cancer cell lines to chemotherapeutic agents. Cycles of starvation were as effective as chemotherapeutic agents in delaying progression of different tumors and increased the effectiveness of these drugs against melanoma, glioma, and breast cancer cells. In mouse models of neuroblastoma, fasting cycles plus chemotherapy drugs—but not either treatment alone—resulted in long-term cancer-free survival. In 4T1 breast cancer cells, short-term starvation resulted in increased phosphorylation of the stress-sensitizing Akt and S6 kinases, increased oxidative stress, caspase-3 cleavage, DNA damage, and apoptosis. These studies suggest that multiple cycles of fasting promote differential stress sensitization in a wide range of tumors and could potentially replace or augment the efficacy of certain chemotherapy drugs in the treatment of various cancers. PMID:22323820

  5. Dual sightline measurements of MeV range deuterons with neutron and gamma-ray spectroscopy at JET

    DEFF Research Database (Denmark)

    Eriksson, J.; Nocente, M.; Binda, F.

    2015-01-01

    Observations made in a JET experiment aimed at accelerating deuterons to the MeV range by third harmonic radio-frequency (RF) heating coupled into a deuterium beam are reported. Measurements are based on a set of advanced neutron and gamma-ray spectrometers that, for the first time, observe the p......, more generally, to studies of the energy distribution of ions in the MeV range in high performance deuterium and deuterium-tritium plasmas....

  6. Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study

    Science.gov (United States)

    Biegun, Aleksandra K.; Seravalli, Enrica; Cambraia Lopes, Patrícia; Rinaldi, Ilaria; Pinto, Marco; Oxley, David C.; Dendooven, Peter; Verhaegen, Frank; Parodi, Katia; Crespo, Paulo; Schaart, Dennis R.

    2012-10-01

    Therapeutic proton and heavier ion beams generate prompt gamma photons that may escape from the patient. In principle, this allows for real-time, in situ monitoring of the treatment delivery, in particular, the hadron range within the patient, by imaging the emitted prompt gamma rays. Unfortunately, the neutrons simultaneously created with the prompt photons create a background that may obscure the prompt gamma signal. To enhance the accuracy of proton dose verification by prompt gamma imaging, we therefore propose a time-of-flight (TOF) technique to reject this neutron background, involving a shifting time window to account for the propagation of the protons through the patient. Time-resolved Monte Carlo simulations of the generation and transport of prompt gamma photons and neutrons upon irradiation of a PMMA phantom with 100, 150 and 200 MeV protons were performed using Geant4 (version 9.2.p02) and MCNPX (version 2.7.D). The influence of angular collimation and TOF selection on the prompt gamma and neutron longitudinal profiles is studied. Furthermore, the implications of the proton beam microstructure (characterized by the proton bunch width and repetition period) are investigated. The application of a shifting TOF window having a width of ΔTOFz = 1.0 ns appears to reduce the neutron background by more than 99%. Subsequent application of an energy threshold does not appear to sharpen the distal falloff of the prompt gamma profile but reduces the tail that is observed beyond the proton range. Investigations of the influence of the beam time structure show that TOF rejection of the neutron background is expected to be effective for typical therapeutic proton cyclotrons.

  7. Are high energy proton beams ideal for AB-BNCT? A brief discussion from the viewpoint of fast neutron contamination control.

    Science.gov (United States)

    Lee, Pei-Yi; Liu, Yuan-Hao; Jiang, Shiang-Huei

    2014-06-01

    High energy proton beam (>8MeV) is favorable for producing neutrons with high yield. However, the produced neutrons are of high energies. These high energy neutrons can cause severe fast neutron contamination and degrade the BNCT treatment quality if they are not appropriately moderated. Hence, this study aims to briefly discuss the issue, from the viewpoint of fast neutron contamination control, whether high energy proton beam is ideal for AB-BNCT or not. In this study, D2O, PbF4, CaF2, and Fluental(™) were used standalone as moderator materials to slow down 1-, 6-, and 10-MeV parallelly incident neutrons. From the calculated results, we concluded that neutrons produced by high energy proton beam could not be easily moderated by a single moderator to an acceptable contamination level and still with reasonable epithermal neutron beam intensity. Hence, much more complicated and sophisticated designs of beam shaping assembly have to be developed when using high energy proton beams.

  8. Plasticization effect of C{sub 60} on the fast dynamics of polystyrene and related polymers: an incoherent neutron scattering study

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, Alejandro; Ruppel, Markus; Cabral, Joao T [Department of Chemical Engineering, Imperial College, London SW7 2AZ (United Kingdom); Douglas, Jack F [Polymers Division, NIST, Gaithersburg, MD 20899 (United States)], E-mail: j.cabral@imperial.ac.uk

    2008-03-12

    We utilize inelastic incoherent neutron scattering (INS) to quantify how fullerenes affect the 'fast' molecular dynamics of a family of polystyrene related macromolecules. In particular, we prepared bulk nanocomposites of (hydrogenous and ring-deuterated) polystyrene and poly(4-methyl styrene) using a rapid precipitation method where the C{sub 60} relative mass fraction ranged from 0% to 4%. Elastic window scan measurements, using a high resolution (0.9 {mu}eV) backscattering spectrometer, are reported over a wide temperature range (2-450 K). Apparent Debye-Waller (DW) factors , characterizing the mean-square amplitude of proton displacements, are determined as a function of temperature, T. We find that the addition of C{sub 60} to these polymers leads to a progressive increase in relative to the pure polymer value over the entire temperature range investigated, where the effect is larger for larger nanoparticle concentration. This general trend seems to indicate that the C{sub 60} nanoparticles plasticize the fast ({approx}10{sup -15} s) local ({approx}1 A) dynamics of these polymer glasses. Generally, we expect nanoparticle additives to affect polymer dynamics in a similar fashion to thin films in the sense that the high interfacial area may cause both a speeding up and slowing down of the glass state dynamics depending on the polymer-surface interaction.

  9. Development of a Scanning Microscale Fast Neutron Irradiation Platform for Examining the Correlation Between Local Neutron Damage and Graphite Microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Pinhero, Patrick [Univ. of Missouri, Columbia, MO (United States); Windes, William [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-10

    The fast particle radiation damage effect of graphite, a main material in current and future nuclear reactors, has significant influence on the utilization of this material in fission and fusion plants. Atoms on graphite crystals can be easily replaced or dislocated by fast protons and result in interstitials and vacancies. The currently accepted model indicates that after most of the interstitials recombine with vacancies, surviving interstitials form clusters and furthermore gather to create loops with each other between layers. Meanwhile, surviving vacancies and interstitials form dislocation loops on the layers. The growth of these inserted layers cause the dimensional increase, i.e. swelling, of graphite. Interstitial and vacancy dislocation loops have been reported and they can easily been observed by electron microscope. However, observation of the intermediate atom clusters becomes is paramount in helping prove this model. We utilize fast protons generated from the University of Missouri Research Reactor (MURR) cyclotron to irradiate highly- oriented pyrolytic graphite (HOPG) as target for this research. Post-irradiation examination (PIE) of dosed targets with high-resolution transmission electron microscopy (HRTEM) has permit observation and analysis of clusters and dislocation loops to support the proposed theory. Another part of the research is to validate M.I. Heggie’s Ruck and Tuck model, which introduced graphite layers may fold under fast particle irradiation. Again, we employed microscopy to image irradiated specimens to determine how the extent of Ruck and Tuck by calculating the number of folds as a function of dose. Our most significant accomplishment is the invention of a novel class of high-intensity pure beta-emitters for long-term lightweight batteries. We have filed four invention disclosure records based on the research conducted in this project. These batteries are lightweight because they consist of carbon and tritium and can be

  10. Characterization of mono-ethylene-glycol based industrial polyurethanes samples by fast-neutron radiography and neutron tomography

    Science.gov (United States)

    Rogante, Massimo; Söllradl, Stefan

    2016-09-01

    A complicated structural organization of polyurethanes may have a strong influence on the materials functional properties. Under particular conditions such as mechanical and thermal loading and aging, it leads to the material degradation, even in fresh-prepared bulk polymers and especially if defects are present in the material. Unwanted bubbles can be observed, which form during the expansion of the mixture during its chemical reaction and remain present in the final product. These macro-, micro- and nano-bubbles influence the material's performance. In this work, neutron radiography and tomography have been adopted to characterize at a macro-scale level the bulk of commercially available polyurethane samples, obtained from dissimilar- mixture ratios with different densities and branching levels as well as from different zones of the production mould. The characterisation allowed an estimation of the different dense materials - as they are used, e.g., in soles of shoes - as well as the invisible defects like pores and cracks, responsible for the materials fracture by mechanical loading. The obtained information are expected to be useful for various industrial sectors such as automotive and footwear industry. It will be completed by applying SANS, which has already proved to characterize the microstructure of the bulk-polymer with respect to nano-pores, micro-cracks and their arrangement in the polymer matrix.

  11. The perturbation of backscattered fast neutrons spectrum caused by the resonances of C, N and O for possible use in pyromaterial detection

    Science.gov (United States)

    Abedin, Ahmad Firdaus Zainal; Ibrahim, Noorddin; Zabidi, Noriza Ahmad; Abdullah, Abqari Luthfi Albert

    2015-04-01

    Neutron radiation is able to determine the signature of land mine detection based on backscattering energy spectrum of landmine. In this study, the Monte Carlo simulation of backscattered fast neutrons was performed on four basic elements of land mine; hydrogen, nitrogen, oxygen and carbon. The moderation of fast neutrons to thermal neutrons and their resonances cross-section between 0.01 eV until 14 MeV were analysed. The neutrons energies were divided into 29 groups and ten million neutrons particles histories were used. The geometries consist of four main components: neutrons source, detectors, landmine and soil. The neutrons source was placed at the origin coordinate and shielded with carbon and polyethylene. Americium/Beryllium neutron source was placed inside lead casing of 1 cm thick and 2.5 cm height. Polyethylene was used to absorb and disperse radiation and was placed outside the lead shield of width 10 cm and height 7 cm. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of Helium-3 was used for neutron detection as it has high absorption cross section for thermal neutrons. For the anomaly, the physical is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. The results show that the energy spectrum for the four basic elements of landmine with specific pattern which can be used as indication for the presence of landmines.

  12. The perturbation of backscattered fast neutrons spectrum caused by the resonances of C, N and O for possible use in pyromaterial detection

    Energy Technology Data Exchange (ETDEWEB)

    Abedin, Ahmad Firdaus Zainal, E-mail: firdaus087@gmail.com; Ibrahim, Noorddin; Zabidi, Noriza Ahmad; Abdullah, Abqari Luthfi Albert [Department of Defence Science, Universiti Pertahanan Nasional Malaysia, Kem Sungai Besi, Kuala Lumpur 57000 (Malaysia)

    2015-04-29

    Neutron radiation is able to determine the signature of land mine detection based on backscattering energy spectrum of landmine. In this study, the Monte Carlo simulation of backscattered fast neutrons was performed on four basic elements of land mine; hydrogen, nitrogen, oxygen and carbon. The moderation of fast neutrons to thermal neutrons and their resonances cross-section between 0.01 eV until 14 MeV were analysed. The neutrons energies were divided into 29 groups and ten million neutrons particles histories were used. The geometries consist of four main components: neutrons source, detectors, landmine and soil. The neutrons source was placed at the origin coordinate and shielded with carbon and polyethylene. Americium/Beryllium neutron source was placed inside lead casing of 1 cm thick and 2.5 cm height. Polyethylene was used to absorb and disperse radiation and was placed outside the lead shield of width 10 cm and height 7 cm. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of Helium-3 was used for neutron detection as it has high absorption cross section for thermal neutrons. For the anomaly, the physical is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. The results show that the energy spectrum for the four basic elements of landmine with specific pattern which can be used as indication for the presence of landmines.

  13. Effect of Synaptic Connectivity on Long-Range Synchronization of Fast Cortical Oscillations

    Science.gov (United States)

    Bazhenov, M.; Rulkov, N. F.; Timofeev, I.

    2008-01-01

    Cortical gamma oscillations in the 20- to 80-Hz range are associated with attentiveness and sensory perception and have strong connections to both cognitive processing and temporal binding of sensory stimuli. These gamma oscillations become synchronized within a few milliseconds over distances spanning a few millimeters in spite of synaptic delays. In this study using in vivo recordings and large-scale cortical network models, we reveal a critical role played by the network geometry in achieving precise long-range synchronization in the gamma frequency band. Our results indicate that the presence of many independent synaptic pathways in a two-dimensional network facilitate precise phase synchronization of fast gamma band oscillations with nearly zero phase delays between remote network sites. These findings predict a common mechanism of precise oscillatory synchronization in neuronal networks. PMID:18632897

  14. Development of a fast proton range radiography system for quality assurance in hadrontherapy

    Science.gov (United States)

    Bucciantonio, M.; Amaldi, U.; Kieffer, R.; Sauli, F.; Watts, D.

    2013-12-01

    We describe the development of a Proton Range Radiography system with an imaging area of 30×30 cm2 for two dimensional mapping of the integrated density in a target. Proton transmission radiographic images are produced by measuring, with a pair of position-sensitive detectors (GEM chambers), the direction of the protons transmitted through the patient and, with a stack of scintillators, the residual range of the protons leaving the patient. To match the data rate requirements of an in-beam diagnostic, a novel data acquisition system for the tracking detectors has been designed to operate at 1 MHz data flow. Laboratory tests exposing the GEM detector with high flux X-rays confirm the fast response of the new data acquisition system. Images of several phantoms have been recorded to demonstrate the GEM position accuracy.

  15. Development of a fast proton range radiography system for quality assurance in hadrontherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bucciantonio, M., E-mail: martina.bucciantonio@cern.ch [Tera Foundation, Novara (Italy); Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics, University of Bern, Bern (Switzerland); Amaldi, U.; Kieffer, R.; Sauli, F.; Watts, D. [Tera Foundation, Novara (Italy)

    2013-12-21

    We describe the development of a Proton Range Radiography system with an imaging area of 30×30 cm{sup 2} for two dimensional mapping of the integrated density in a target. Proton transmission radiographic images are produced by measuring, with a pair of position-sensitive detectors (GEM chambers), the direction of the protons transmitted through the patient and, with a stack of scintillators, the residual range of the protons leaving the patient. To match the data rate requirements of an in-beam diagnostic, a novel data acquisition system for the tracking detectors has been designed to operate at 1 MHz data flow. Laboratory tests exposing the GEM detector with high flux X-rays confirm the fast response of the new data acquisition system. Images of several phantoms have been recorded to demonstrate the GEM position accuracy.

  16. Total kinetic energy release in the fast neutron-induced fission of $^{235}$U

    CERN Document Server

    Yanez, R; King, J; Barrett, J S; Fotiades, N; Lee, H Y

    2016-01-01

    We have measured the total kinetic energy (TKE) release for the $^{235}$U(n,f) reaction for $E_{n}$=2-100 MeV using the 2E method with an array of Si PIN diode detectors. The neutron energies were determined by time of flight measurements using the white spectrum neutron beam at the LANSCE facility. To benchmark the TKE measurement, the TKE release for $^{235}$U(n$_{th}$,f) was also measured using a thermal neutron beam from the Oregon State University TRIGA reactor, giving pre-neutron emission $E^*_{TKE}=170.7\\pm0.4$ MeV in good agreement with known values. Our measurements are thus absolute measurements. The TKE in $^{235}$U(n,f) decreases non-linearly from 169.0 MeV to 161.4 MeV for $E_{n}$=2-90 MeV. Comparison of the data with the multi-modal fission model of Brosa indicates the TKE decrease is a consequence of the growth of symmetric fission and the corresponding decrease of asymmetric fission with increasing neutron energy. The average TKE associated with the Brosa superlong, standard I and standard II ...

  17. Total kinetic energy release in the fast neutron-induced fission of $^{235}$U

    CERN Document Server

    Yanez, R; King, J; Barrett, J S; Fotiades, N; Lee, H Y

    2015-01-01

    We have measured the total kinetic energy (TKE) release for the $^{235}$U(n,f) reaction for $E_{n}$=2-100 MeV using the 2E method with an array of Si PIN diode detectors. The neutron energies were determined by time of flight measurements using the white spectrum neutron beam at the LANSCE facility. (To calibrate the apparatus, the TKE release for $^{235}$U(n$_{th}$,f) was also measured using a thermal neutron beam from the OSU TRIGA reactor). The TKE decreases non-linearly from 169.0 MeV to 161.4 MeV for $E_{n}$=2-90 MeV. The standard deviation of the TKE distribution is constant from $E_{n}$=20-90 MeV. Comparison of the data with the multi-modal fission model of Brosa indicates the TKE decrease is a consequence of the growth of symmetric fission and the corresponding decrease of asymmetric fission with increasing neutron energy. The average TKE associated with the Brosa superlong, standard I and standard II modes for a given mass is independent of neutron energy.

  18. Personal dose equivalent conversion coefficients for neutron fluence over the energy range of 20 to 250 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Mclean, Thomas D [Los Alamos National Laboratory; Justus, Alan L [Los Alamos National Laboratory; Gadd, S Milan [Los Alamos National Laboratory; Olsher, Richard H [RP-2; Devine, Robert T [RP-2

    2009-01-01

    Monte Carlo simulations were performed to extend existing neutron personal dose equivalent fluence-to-dose conversion coefficients to an energy of 250 MeV. Presently, conversion coefficients, H(p,slab)(10,alpha)/Phi, are given by ICRP-74 and ICRU-57 for a range of angles of radiation incidence (alpha = 0, 15, 30, 45, 60 and 75 degrees ) in the energy range from thermal to 20 MeV. Standard practice has been to base operational dose quantity calculations <20 MeV on the kerma approximation, which assumes that charged particle secondaries are locally deposited, or at least that charged particle equilibrium exists within the tally cell volume. However, with increasing neutron energy the kerma approximation may no longer be valid for some energetic secondaries such as protons. The Los Alamos Monte Carlo radiation transport code MCNPX was used for all absorbed dose calculations. Transport models and collision-based energy deposition tallies were used for neutron energies >20 MeV. Both light and heavy ions (HIs) (carbon, nitrogen and oxygen recoil nuclei) were transported down to a lower energy limit (1 keV for light ions and 5 MeV for HIs). Track energy below the limit was assumed to be locally deposited. For neutron tracks <20 MeV, kerma factors were used to obtain absorbed dose. Results are presented for a discrete set of angles of incidence on an ICRU tissue slab phantom.

  19. Fast-neutron total and scattering cross sections of sup 58 Ni and nuclear models

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A.B.; Guenther, P.T.; Whalen, J.F. (Argonne National Lab., IL (United States)); Chiba, S. (Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment)

    1991-07-01

    The neutron total cross sections of {sup 58}Ni were measured from {approx} 1 to > 10 MeV using white-source techniques. Differential neutron elastic-scattering cross sections were measured from {approx} 4.5 to 10 MeV at {approx} 0.5 MeV intervals with {ge} 75 differential values per distribution. Differential neutron inelastic-scattering cross sections were measured, corresponding to fourteen levels with excitations up to 4.8 MeV. The measured results, combined with relevant values available in the literature, were interpreted in terms of optical-statistical and coupled-channels model using both vibrational and rotational coupling schemes. The physical implications of the experimental results nd their interpretation are discussed in the contexts of optical-statistical, dispersive-optical, and coupled-channels models. 61 refs.

  20. Genome-wide analysis of mutations in mutant lineages selected following fast-neutron irradiation mutagenesis of Arabidopsis thaliana

    KAUST Repository

    Belfield, E.J.

    2012-04-12

    Ionizing radiation has long been known to induce heritable mutagenic change in DNA sequence. However, the genome-wide effect of radiation is not well understood. Here we report the molecular properties and frequency of mutations in phenotypically selected mutant lines isolated following exposure of the genetic model flowering plant Arabidopsis thaliana to fast neutrons (FNs). Previous studies suggested that FNs predominantly induce deletions longer than a kilobase in A. thaliana. However, we found a higher frequency of single base substitution than deletion mutations. While the overall frequency and molecular spectrum of fast-neutron (FN)-induced single base substitutions differed substantially from those of "background" mutations arising spontaneously in laboratory-grown plants, G:C>A:T transitions were favored in both. We found that FN-induced G:C>A:T transitions were concentrated at pyrimidine dinucleotide sites, suggesting that FNs promote the formation of mutational covalent linkages between adjacent pyrimidine residues. In addition, we found that FNs induced more single base than large deletions, and that these single base deletions were possibly caused by replication slippage. Our observations provide an initial picture of the genome-wide molecular profile of mutations induced in A. thaliana by FN irradiation and are particularly informative of the nature and extent of genome-wide mutation in lines selected on the basis of mutant phenotypes from FN-mutagenized A. thaliana populations.

  1. Design of a single moderator-type neutron spectrometer with enhanced energy resolution in the energy range from a few to 100 keV

    Energy Technology Data Exchange (ETDEWEB)

    Tanimura, Y. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan)]. E-mail: tanimura@popsvr.tokai.jaeri.go.jp; Saegusa, J. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Yoshizawa, M. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Yoshida, M. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan)

    2005-08-01

    The moderator structure for a neutron spectrometer was optimized with the Monte Carlo code MCNP-4B. The spectrometer consists of a cylindrical moderator and a position-sensitive thermal neutron detector and obtains energy spectra from thermal neutron distribution along its cylindrical axis. The structure of the moderator was improved by using a low hydrogen density material on one end and a high hydrogen density on the other, and inserting a neutron absorber that eliminates thermal neutron diffusion. This design improves the energy resolution of the spectrometer, especially for low-energy neutrons from a few to 100 keV. The designed spectrometer can be applied to the measurement of energy spectra over a neutron energy range from a few keV to 20 MeV.

  2. Performance of a plasma window for a high pressure differentially pumped deuterium gas target for mono-energetic fast neutron production - Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Beer, A. de; Hershcovitch, A.; Franklyn, C.B.; Straaten, S. van; Guzek, J. E-mail: jguzek@debeers.co.za

    2000-09-01

    The reactions D(d,n){sup 3}He and T(d,n){sup 4}He are frequently used for production of the mono-energetic or quasi mono-energetic neutron beams but successful applications are often limited by the intensity of the generated neutron beams. The development of a suitable neutron source for such applications as studies of resonance phenomena, fast neutron radiography, selective fast neutron activation, explosives and contraband detection and others, depends on the output ion current of the accelerator and the design of the target system. A practical solution for a high pressure gas target was previously developed and successfully implemented at De Beers Diamond Research Laboratory in Johannesburg (Guzek et al., 1999), but it is limited to applications using low (<20%) duty cycle accelerators. The concept of a plasma window for the separation of a high pressure gas target region and accelerator vacuum, that was originally developed by Hershcovitch (1995) for electron welding applications, may be suitable for operation with continuous wave accelerators at high particle current output. Preliminary test results, which have been performed with various gases (argon, helium and deuterium), indicate that implementation of the plasma window into a gas target system, for the production of intense mono-energetic fast neutron beams will be achievable.

  3. Oxidative Damage and Mutagenic Potency of Fast Neutron and UV-B Radiation in Pollen Mother Cells and Seed Yield of Vicia faba L.

    Directory of Open Access Journals (Sweden)

    Ekram Abdel Haliem

    2013-01-01

    Full Text Available In recent years, there has been a great deal of attention toward free radicals, reactive oxygen species (ROS generated by exposure of crop plant cells to physical radiations. Henceforth, the current study was planned to compare oxidative stress and mutagenic potential of different irradiation doses of fast neutron (FN and UV-B on meiotic-pollen mother cells (PMCs, pollen grains (PGs and seeds yielded from irradiated faba beans seedlings. On the cytogenetic level, each irradiation type had special interference with DNA of PMC and exhibited wide range of mutagenic action on the frequency and type of chromosomal anomalies, fertility of PGs and seed yield productivity based on the irradiation exposure dose and radiation sensitivity of faba bean plants compared with un-irradiated ones. On the molecular level, SDS-PAGE and RPAD-PCR analyses of seeds yielded from irradiated seedlings exhibited distinctive polymorphisms based on size, intensity, appearance, and disappearance of polypeptides bands compared with un-irradiated ones. The total values of protein and DNA polymorphisms reached 88% and 90.80% respectively. The neutron fluency (2.3 × 106 n/cm2 and UV-B dose for 1 hr were recorded as bio-positive effects. The present study proved that genetic variations revealed by cytogenetic test could be supported by gene expression (alterations in RAPD and protein profiles.

  4. Development and testing of a fast Fourier transform high dynamic-range spectral diagnostics for millimeter wave characterization

    NARCIS (Netherlands)

    Thoen, D. J.; Bongers, W. A.; Westerhof, E.; Oosterbeek, J. W.; M.R. de Baar,; van den Berg, M. A.; van Beveren, V.; Burger, A.; Goede, A. P. H.; Graswinckel, M. F.; Hennen, B.A.; Schüller, F. C.

    2009-01-01

    A fast Fourier transform (FFT) based wide range millimeter wave diagnostics for spectral characterization of scattered millimeter waves in plasmas has been successfully brought into operation. The scattered millimeter waves are heterodyne downconverted and directly digitized using a fast analog-digi

  5. Final qualification of an industrial wide range neutron instrumentation in the Osiris MTR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Barbot, L.; Normand, S. [CEA, LIST, Laboratoire Capteur et Architectures Electroniques, F-91191 Gif Sur Yvette (France); Pasdeloup, P. [AREVA TA, Controle Commande and Mesures, F-13762 Les Milles (France); Lescop, B. [CEA, INSTN, UEIN, F-91191 Gif Sur Yvette (France)

    2009-07-01

    This work deals with the final qualification of the IRINA in-core neutron flux measurement system in the MTR Osiris reactor. A specific irradiation device has been set up to validate the last changes in the complete system (electronic, transmitting cable and monitor). Experimental results show the IRINA measurement system meet entirely the in-core reactor conditions requirements: a thermal neutron flux from 10{sup 7} n.cm{sup -2}.s{sup -1} up to 10{sup 14} n.cm{sup -2}.s{sup -1} and a temperature of 300 C degrees during a minimum operating time of 1000 hours. (authors)

  6. Systematic Characteristics of Fast Neutron Fission Cross Sections for Actinide Nuclei

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The neutron fission cross sections of actinide nuclei are important data for the design of nuclear reactor and nuclear engineering, and so on. So far, there has been a certain amount of experimental data for the fission cross sections of actinide nuclei. However,

  7. Structural and thermodynamic study of dicesium molybdate Cs2Mo2O7: Implications for fast neutron reactors

    Science.gov (United States)

    Smith, A. L.; Kauric, G.; van Eijck, L.; Goubitz, K.; Wallez, G.; Griveau, J.-C.; Colineau, E.; Clavier, N.; Konings, R. J. M.

    2017-09-01

    The structure of α-Cs2Mo2O7 (monoclinic in space group P21 / c), which can form during irradiation in fast breeder reactors in the space between nuclear fuel and cladding, has been refined in this work at room temperature from neutron diffraction data. Furthermore, the compounds' thermal expansion and polymorphism have been investigated using high temperature X-ray diffraction combined with high temperature Raman spectroscopy. A phase transition has been observed at Ttr(α → β)=(621.9±0.8) K using Differential Scanning Calorimetry, and the structure of the β-Cs2Mo2O7 phase, orthorhombic in space group Pbcm, has been solved ab initio from the high temperature X-ray diffraction data. Furthermore, the low temperature heat capacity of α-Cs2Mo2O7 has been measured in the temperature range T=(1.9-313.2) K using a Quantum Design PPMS (Physical Property Measurement System) calorimeter. The heat capacity and entropy values at T=298.15 K have been derived as Cp,mo (Cs2Mo2O7 , cr , 298.15 K) = (211.9 ± 2.1) J K-1mol-1 and Smo (Cs2Mo2O7 , cr , 298.15 K) = (317.4 ± 4.3) J K-1mol-1 . When combined with the enthalpy of formation reported in the literature, these data yield standard entropy and Gibbs energy of formation as ΔfSmo (Cs2Mo2O7 , cr , 298.15 K) = - (628.2 ± 4.4) J K-1mol-1 and ΔfGmo (Cs2Mo2O7 , cr , 298.15 K) = - (2115.1 ± 2.5) kJmol-1 . Finally, the cesium partial pressure expected in the gap between fuel and cladding following the disproportionation reaction 2Cs2MoO4=Cs2Mo2O7+2Cs(g)+ 1/2 O2(g) has been calculated from the newly determined thermodynamic functions.

  8. Extension and evaluation of the multilevel summation method for fast long-range electrostatics calculations.

    Science.gov (United States)

    Moore, Stan G; Crozier, Paul S

    2014-06-21

    Several extensions and improvements have been made to the multilevel summation method (MSM) of computing long-range electrostatic interactions. These include pressure calculation, an improved error estimator, faster direct part calculation, extension to non-orthogonal (triclinic) systems, and parallelization using the domain decomposition method. MSM also allows fully non-periodic long-range electrostatics calculations which are not possible using traditional Ewald-based methods. In spite of these significant improvements to the MSM algorithm, the particle-particle particle-mesh (PPPM) method was still found to be faster for the periodic systems we tested on a single processor. However, the fast Fourier transforms (FFTs) that PPPM relies on represent a major scaling bottleneck for the method when running on many cores (because the many-to-many communication pattern of the FFT becomes expensive) and MSM scales better than PPPM when using a large core count for two test problems on Sandia's Redsky machine. This FFT bottleneck can be reduced by running PPPM on only a subset of the total processors. MSM is most competitive for relatively low accuracy calculations. On Sandia's Chama machine, however, PPPM is found to scale better than MSM for all core counts that we tested. These results suggest that PPPM is usually more efficient than MSM for typical problems running on current high performance computers. However, further improvements to MSM algorithm could increase its competitiveness for calculation of long-range electrostatic interactions.

  9. China Experimental Fast Reactor(CEFR)——Criterion of Criticality for Reactor With External Neutron Source

    Institute of Scientific and Technical Information of China (English)

    ZHAOYu-sen

    2003-01-01

    There is a neutron source with 109 s-1 neutrons in core of CEFR during start up test and operation of CEFR. For judging the criticality of reactor with external neutron source and near criticality, it is important that the neutron level changes in core with time must be understood after introducing positive reactivity to core with external neutron source.

  10. Characterization of extended range Bonner Sphere Spectrometers in the CERF high-energy broad neutron field at CERN

    Science.gov (United States)

    Agosteo, S.; Bedogni, R.; Caresana, M.; Charitonidis, N.; Chiti, M.; Esposito, A.; Ferrarini, M.; Severino, C.; Silari, M.

    2012-12-01

    The accurate determination of the ambient dose equivalent in the mixed neutron-photon fields encountered around high-energy particle accelerators still represents a challenging task. The main complexity arises from the extreme variability of the neutron energy, which spans over 10 orders of magnitude or more. Operational survey instruments, which response function attempts to mimic the fluence-to-ambient dose equivalent conversion coefficient up to GeV neutrons, are available on the market, but their response is not fully reliable over the entire energy range. Extended range rem counters (ERRC) do not require the exact knowledge of the energy distribution of the neutron field and the calibration can be done with a source spectrum. If the actual neutron field has an energy distribution different from the calibration spectrum, the measurement is affected by an added uncertainty related to the partial overlap of the fluence-to-ambient dose equivalent conversion curve and the response function. For this reason their operational use should always be preceded by an "in-field" calibration, i.e. a calibration made against a reference instrument exposed in the same field where the survey-meter will be employed. In practice the extended-range Bonner Sphere Spectrometer (ERBSS) is the only device which can serve as reference instrument in these fields, because of its wide energy range and the possibility to assess the neutron fluence and the ambient dose equivalent (H*(10)) values with the appropriate accuracy. Nevertheless, the experience gained by a number of experimental groups suggests that mandatory conditions for obtaining accurate results in workplaces are: (1) the use of a well-established response matrix, thus implying validation campaigns in reference monochromatic neutrons fields, (2) the expert and critical use of suitable unfolding codes, and (3) the performance test of the whole system (experimental set-up, elaboration and unfolding procedures) in a well

  11. Measured and calculated fast neutron spectra in a depleted uranium and lithium hydride shielded reactor

    Science.gov (United States)

    Lahti, G. P.; Mueller, R. A.

    1973-01-01

    Measurements of MeV neutron were made at the surface of a lithium hydride and depleted uranium shielded reactor. Four shield configurations were considered: these were assembled progressively with cylindrical shells of 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, and 3-centimeter-thick depleted uranium. Measurements were made with a NE-218 scintillation spectrometer; proton pulse height distributions were differentiated to obtain neutron spectra. Calculations were made using the two-dimensional discrete ordinates code DOT and ENDF/B (version 3) cross sections. Good agreement between measured and calculated spectral shape was observed. Absolute measured and calculated fluxes were within 50 percent of one another; observed discrepancies in absolute flux may be due to cross section errors.

  12. Gamma-rays from $^{nat}$Sn and $^{nat}$C induced by fast neutrons

    CERN Document Server

    Kadenko, Igor; Bondar, Borys; Gorbachenko, Oleksandr; Leshchenko, Borys; Solodovnyk, Kateryna

    2016-01-01

    The cross-sections of prompt gamma-ray production from $^{nat}$Sn and $^{nat}$C elements induced by 14.1-MeV neutrons were measured. The time-of-flight technique was used for n-gamma discrimination. The experimental results were compared with theoretical calculations performed by Empire 3.2 and Talys 1.6 codes using different models for photon strength function and nuclear level density.

  13. Fast-neutron interaction with the fission product {sup 103}Rh

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A.B. [Argonne National Lab., IL (United States)]|[Arizona Univ., Tucson, AZ (United States); Guenther, P.T. [Argonne National Lab., IL (United States)

    1993-09-01

    Neutron total and differential elastic- and inelastic-scattering cross sections of {sup 103}Rh are measured from {approximately} 0.7 to 4.5 MeV (totals) and from {approximately} 1.5 to 10 MeV (scattering) with sufficient detail to define the energy-averaged behavior of the neutron processes. Neutrons corresponding to excitations of groups of levels at 334 {plus_minus} 13, 536 {plus_minus} 10, 648 {plus_minus} 25, 796 {plus_minus} 20, 864 {plus_minus} 22, 1120 {plus_minus} 22, 1279 {plus_minus} 60, 1481 {plus_minus} 27 and 1683 {plus_minus} 39 keV were observed. Additional groups at 1840 {plus_minus} 79 and 1991 {plus_minus} 71 key were tentatively identified. Assuming the target is a collective nucleus reasonably approximated by a simple one-phonon vibrator, spherical-optical, dispersive-optical, and coupled-channels models were developed from the data base with attention to the parameterization of the large inelastic-scattering cross sections. The physical properties of these models are compared with theoretical predictions and the systematics of similar model parameterizations in this mass region. In particular, it is shown that the inelastic-scattering cross section of the {sup 103}Rh fission product is large at the relatively low energies of applied interest.

  14. Compact Neutron Generators for Medical, Home Land Security, and Planetary Exploration

    CERN Document Server

    Reijonen, Jani

    2005-01-01

    The Plasma and Ion Source Technology Group at Lawrence Berkeley National Laboratory has developed various types of advanced D-D (neutron energy 2.5 MeV), D-T (14 MeV) and T-T (0 - 9 MeV) neutron generators for wide range of applications. These applications include medical (Boron Neutron Capture Therapy), homeland security (Prompt Gamma Activation Analysis, Fast Neutron Activation Analysis and Pulsed Fast Neutron Transmission Spectroscopy) and planetary exploration in form of neutron based, sub-surface hydrogen detection systems. These neutron generators utilize RF induction discharge to ionize the deuterium/tritium gas. This discharge method provides high plasma density for high output current, high atomic species from molecular gases, long life operation and versatility for various discharge chamber geometries. Three main neutron generator developments are discussed here: high neutron output co-axial neutron generator for BNCT applications, point neutron generator for security applications, compact and sub-c...

  15. A high-rate detection system to study parity violation with polarized epithermal neutrons at LANSCE

    Energy Technology Data Exchange (ETDEWEB)

    Knudson, J.N.; Bowman, J.D. [Los Alamos National Lab., NM (United States); Crawford, B.E. [Duke Univ., Durham, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC (United States)

    1995-07-01

    We describe an apparatus for studies of parity violation in neutron-nucleus scattering. This experiment requires longitudinally polarized neutrons from the Los Alamos Neutron Scattering Center over the energy-range from 1 to 1000 eV, the ability to reverse the neutron spin without otherwise affecting the apparatus, the ability to detect neutrons at rates up to 500 MHz, and an appropriate data acquisition system. We will discuss the neutron polarizer, fast neutron spin reverser, detector for transmitted neutrons, and high rate data acquisition system.

  16. Fast neutron tolerance of the perpendicular-anisotropy CoFeB-MgO magnetic tunnel junctions with junction diameters between 46 and 64 nm

    Science.gov (United States)

    Narita, Yuzuru; Takahashi, Yutaka; Harada, Masahide; Oikawa, Kenichi; Kobayashi, Daisuke; Hirose, Kazuyuki; Sato, Hideo; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo

    2017-08-01

    This work represents the first-ever investigation of the effects of fast neutron exposure on the perpendicular-anisotropy CoFeB-MgO magnetic tunnel junctions (p-MTJs) with practical junction diameters (D) between 46 and 64 nm. In this study, 461 p-MTJs, each with a tunnel magnetoresistance (TMR) ratio above 90%, were irradiated with fast neutrons at a total 1 MeV equivalent fluence of 3.79 × 1012 cm-2, corresponding to 1.90 × 1011 h irradiation with fast atmospheric neutrons (20 cm-2 h-1), without applying a bias voltage. Following irradiation, there were no changes in the properties of these devices, such as their resistance versus magnetic field curves, resistance values in the parallel and anti-parallel states, or TMR ratios, regardless of the neutron fluence. On the basis of these data, the nuclear reactions that occur under the specific experimental neutron irradiation conditions employed in this work are discussed.

  17. Paving the Road for Modern Particle Therapy – What can we Learn from the experience gained with Fast Neutron Therapy in Munich?

    Directory of Open Access Journals (Sweden)

    Hanno Martin Specht

    2015-11-01

    Full Text Available While neutron therapy was a highly topical subject in the 70’s and 80’s, today there are only a few remaining facilities offering fast neutron therapy. Nevertheless, up to today more than 30,000 patients were treated with neutron therapy. For some indications like salivary gland tumors and malignant melanoma there is clinical evidence that the addition of Fast Neutron Therapy (FNT leads to superior local control compared to photon treatment alone. FNT was available in Munich from 1985 until 2000 at the RENT facility (Reactor Neutron Therapy. Patient treatment continued at the new research reactor FRM II in 2007 under improved treatment conditions and today it can still be offered to selected patients as an individual treatment option. As there is a growing interest in high-linear energy transfer (LET therapy with new hadron therapy centers emerging around the globe, the clinical data generated by neutron therapy might help to develop biologically driven treatment planning algorithms. Also FNT might experience its resurgence as a combinational partner of modern immunotherapies.

  18. Fast neutron damage studies of La/sub 1. 85/Sr/sub 0. 15/CuO/sub 4/

    Energy Technology Data Exchange (ETDEWEB)

    Sekula, S.T.; Christen, D.K.; Kerchner, H.R.; Thompson, J.R.; Boatner, L.A.; Sales, B.C.

    1987-04-01

    The effect of fast neutron damage on the superconducting transition temperature T/sub c/ and the critical current density j/sub c/ of the compound La/sub 1.85/Sr/sub 0.15/CuO/sub 4/ has been investigated. Irradiation to a fluence of 1.3 x 10/sup 18/ n/cm/sup 2/ (E > 0.1 MeV) resulted in a decrease of T/sub c/ of about 3 K while j/sub c/ at 4.2 K and H = 2 T increased by a factor of two to 1.2 x 10/sup 4/ A/cm/sup 2/.

  19. Maxillo-dental lesions produced in cats, after gamma and fast neutron irradiation. Radiographical and microradiographical study

    Energy Technology Data Exchange (ETDEWEB)

    Dambrain, R.; Dhem, A.; Meulders, J.P.; Wambersie, A.

    1988-01-01

    Gamma doses of 50 Gy, in 5 fractions over 29 days, induce severe modifications of the irradiated jaw in the cat, as shown by radiographical and microradiographical techniques. Four out 5 animals could survive up to one year; a fifth one died as a consequence of osteoradionecrosis. In addition, 2 animals, on which a tooth extraction was performed, died from osteoradionecrosis (role of trauma). Similar irradiations were performed with fast neutrons d(50) + Be at a total dose of 16.1 Gy in 5 fractions over 29 days. The ratio 50 Gy/16.1 Gy = 3.1 is the CNPF adopted for neutrontherapy applications at Louvain-la-Neuve. This irradiation was well tolerated by 7/7 animals. Only alveolodental ankylosis was observed in 3 cases, as well as a slight reduction in bone vitality in the dorsal part of the jaw. An eighth animal died from osteoradionecrosis induced by tooth extraction.

  20. Dark Matter-induced Collapse of Neutron Stars: A Possible Link Between Fast Radio Bursts and the Missing Pulsar Problem

    CERN Document Server

    Fuller, Jim

    2014-01-01

    Fast radio bursts (FRBs) are an emerging class of short and bright radio transients whose sources remain enigmatic. Within the galactic center, the non-detection of pulsars within the inner $\\sim \\!10\\,{\\rm pc}$ has created a missing pulsar problem that has intensified with time. With all reserve, we advance the notion that the two problems could be linked by a common solution: the collapse of neutron stars (NS) due to capture and sedimentation of dark matter (DM) within their cores. Bramante \\& Linden (2014), Phys.\\ Rev.\\ Lett.~19, 191301 showed that certain DM properties allow for rapid NS collapse within the high DM density environments near galactic centers while permitting NS survival elsewhere. Each DM-induced collapse could generate an FRB as the NS magnetosphere is suddenly expelled. This scenario could explain several features of FRBs: their short time scales, large energies, locally produced scattering tails, and high event rates. Our scenario predicts that FRBs are localized to galactic centers...

  1. Defects in metal crystals. Progress report, May 1, 1976--April 30, 1977. [Heavy ions and fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Seidman, D N

    1977-02-01

    Work performed during 1976 to investigate point defects, aggregates of point defects and their interactions with one another is described. Strong emphasis is placed on the use of different irradiating species (300 to 700 eV Xe/sup +/ ions, 300 eV and 30 keV He/sup +/ ions, 20- to 40-keV W/sup +/ ions, 20- to 40-keV Mo/sup +/ ions, 20- to 40-keV Cr/sup +/ ions and fast neutrons) to introduce both vacancies and interstitials in a number of pure metals (Mo, W, Au, Ta) and alloys (Pt-Au, W-Re, Mo-Ti, Mo-Ti-Zr, Ni/sub 4/Mo, Ni/sub 3/Fe, Ni/sub 3/Mn, low swelling 316 stainless steel and commercial 316 stainless steel). (GHT)

  2. Real-time measurement of low-energy-range neutron spectra on board the space shuttle STS-89 (S/MM-8).

    Science.gov (United States)

    Matsumoto, H; Goka, T; Koga, K; Iwai, S; Uehara, T; Sato, O; Takagi, S

    2001-06-01

    We have developed a real-time, Bonner Ball-type (neutron energy range is from thermal to 15 MeV) neutron spectral measurement system (Bonner Ball Neutron Detector (BBND)) for use on board the International Space Station (ISS). From measurements taken inside STS-89 (S/MM-8), we successfully distinguished neutrons from protons and other particles in a mixed radiation field; a task hitherto considered difficult. Although the experimental period was short, only 3.5 days (January 24-27, 1998), we were able to obtain energy spectral data and the Earth's neutron dose-equivalent map for the ISS orbital conditions (altitude 400 km, orbit inclination angle 51.6 degrees). A method for calculating the neutron energy spectrum and compensating for the particle interaction with the sensors is also described in detail.

  3. Study on γ-ray exposure buildup factors and fast neutron-shielding properties of some building materials

    Science.gov (United States)

    Singh, Vishwanath P.; Badiger, N. M.; El-Khayatt, A. M.

    2014-06-01

    We have computed γ-ray exposure buildup factors (EBF) of some building materials; glass, marble, flyash, cement, limestone, brick, plaster of paris (POP) and gypsum for energy 0.015-15 MeV up to 40 mfp (mfp, mean free path) penetration depth. Also, the macroscopic effective removal cross-sections (ΣR) for fast neutron were calculated. We discussed the dependency of EBF values on photon energy, penetration depth and chemical elements. The half-value layer and kinetic energy per unit mass relative to air of building materials were calculated for assessment of shielding effectiveness. Shielding thicknesses for glass, marble, flyash, cement, limestone and gypsum plaster (or Plaster of Paris, POP) were found comparable with ordinary concrete. Among the studied materials limestone and POP showed superior shielding properties for γ-ray and neutron, respectively. Radiation safety inside houses, schools and primary health centers for sheltering and annual dose can be assessed by the determination of shielding parameters of common building materials.

  4. Characterization and simulation of fast neutron detectors based on surface-barrier VPE GaAs structures with polyethylene converter

    Science.gov (United States)

    Chernykh, A. V.; Chernykh, S. V.; Baryshnikov, F. M.; Didenko, S. I.; Burtebayev, N.; Britvich, G. I.; Kostin, M. Yu.; Chubenko, A. P.; Nassurlla, Marzhan; Nassurlla, Maulen; Kerimkulov, Zh.; Zholdybayev, T.; Glybin, Yu. N.; Sadykov, T. Kh.

    2016-12-01

    Fast neutron detectors with an active area of 80 mm2 based on surface-barrier VPE GaAs structures were fabricated and tested. Polyethylene with density of 0.90 g/cm3 was used as a converter layer. The recoil-proton surface-barrier sensor was fabricated on high purity VPE GaAs epilayers with a thickness of 50 μm. The neutron detection efficiency measured with a 241Am-Be source was 1.30 · 10-3 puls./neutr. for the PE converter thickness of 670 μm. The signal-to-gamma-background ratio was at the level of 50. Simulation of the detector characteristics with Geant4 toolkit has showed good correlation with the experimental data and allowed to estimate the maximal theoretical detection efficiency of the detector which is determined by the PE converter and equals to 1.37 · 10-3 puls./neutr. The difference between the measured and simulated values of the detection efficiency is due to the fact that the events with energies below 0.5 MeV were not taken into account during the measurements.

  5. Inverse magnetocaloric effect in Ce(Fe{sub 0.96}Ru{sub 0.04}){sub 2}: Effect of fast neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dube, V.; Mishra, P. K.; Prajapat, C. L.; Singh, M. R.; Ravikumar, G. [Technical Physics Division, Bhabha Atomic Research Centre, Mumbai-4000085 (India); Rajarajan, A. K.; Sastry, P. U. [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai-4000085 (India); Thakare, S. V. [Radio Pharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai-4000085 (India)

    2013-02-05

    We have shown the effect of fast neutron irradiation on the magnetic phase transition and magnetocaloric effect (MCE) in a doped Ce(Fe{sub 0.96}Ru{sub 0.04}){sub 2}, intermettalic. We show that this leads to suppression of MCE and a to a disordered ferromagnetic phase.

  6. HADES. A computer code for fast neutron cross section from the Optical Model; HADES. Un programa numerico para el calculo de seccciones eficaces neutronicas mediante el modelo optico

    Energy Technology Data Exchange (ETDEWEB)

    Guasp, J.; Navarro, C.

    1973-07-01

    A FORTRAN V computer code for UNIVAC 1108/6 using a local Optical Model with spin-orbit interaction is described. The code calculates fast neutron cross sections, angular distribution, and Legendre moments for heavy and intermediate spherical nuclei. It allows for the possibility of automatic variation of potential parameters for experimental data fitting. (Author) 55 refs.

  7. Fast discrimination of neutrons from ({alpha},n) and fission sources

    Energy Technology Data Exchange (ETDEWEB)

    Apfel, R.E. [Yale Univ., New Haven, CT (United States). Dept. of Mechanical Engineering]|[Apfel Enterprises Inc., New Haven, CT (United States); d`Errico, F. [Pisa Univ. (Italy). Dipt. di Costruzioni Meccaniche e Nucleari; Martin, J.D. [Apfel Enterprises Inc., New Haven, CT (United States)

    1997-09-01

    Numerical and experimental investigations were carried out in order to test the possibility of rapidly distinguishing ({alpha},n) from fission neutron source by means of superheated drop detectors (SDDs). This was achieved by measuring the ratio between the response of two detectors operating at 30{sup o}C: SDD-1000, which has a threshold at about 0.5 MeV, and SDD-6000, which has a threshold near 4 MeV. The approach holds promise as it appears suitable for the development of compact instrumentation for safeguards verification purposes. (author).

  8. Fast Neutron Transport in the Biological Shielding Model and Other Regions of the VVER-1000 Mock-Up on the LR-0 Research Reactor

    Science.gov (United States)

    Košťál, Michal; Milčák, Ján; Cvachovec, František; Jánský, Bohumil; Rypar, Vojtěch; Juříček, Vlastimil; Novák, Evžen; Egorov, Alexander; Zaritskiy, Sergey

    2016-02-01

    A set of benchmark experiments was carried out in the full scale VVER-1000 mock-up on the reactor LR-0 in order to validate neutron transport calculation methodologies and to perform the optimization of the shape and locations of neutron flux operation monitors channels inside the shielding of the new VVER-1000 type reactors. Compared with previous experiments on the VVER-1000 mock-up on the reactor LR-0, the fast neutron spectra were measured in the extended neutron energy interval (0.1-10 MeV) and new calculations were carried out with the MCNPX code using various nuclear data libraries (ENDF/B VII.0, JEFF 3.1, JENDL 3.3, JENDL 4, ROSFOND 2009, and CENDL 3.1). Measurements and calculations were carried out at different points in the mock-up. The calculation and experimental data are compared.

  9. Fast Neutron Transport in the Biological Shielding Model and Other Regions of the VVER-1000 Mock-Up on the LR-0 Research Reactor

    Directory of Open Access Journals (Sweden)

    Košťál Michal

    2016-01-01

    Full Text Available A set of benchmark experiments was carried out in the full scale VVER-1000 mock-up on the reactor LR-0 in order to validate neutron transport calculation methodologies and to perform the optimization of the shape and locations of neutron flux operation monitors channels inside the shielding of the new VVER-1000 type reactors. Compared with previous experiments on the VVER-1000 mock-up on the reactor LR-0, the fast neutron spectra were measured in the extended neutron energy interval (0.1–10 MeV and new calculations were carried out with the MCNPX code using various nuclear data libraries (ENDF/B VII.0, JEFF 3.1, JENDL 3.3, JENDL 4, ROSFOND 2009, and CENDL 3.1. Measurements and calculations were carried out at different points in the mock-up. The calculation and experimental data are compared.

  10. A simulation study of fast neutron interrogation for standoff detection of improvised explosive devices

    Science.gov (United States)

    Heider, S. A.; Dunn, W. L.

    2015-11-01

    The signature-based radiation-scanning technique utilizes radiation detector responses, called "signatures," and compares these to "templates" in order to differentiate targets that contain certain materials, such as explosives or drugs, from those that do not. Our investigations are aimed at the detection of nitrogen-rich explosives contained in improvised explosive devices. We use the term "clutter" to refer to any non-explosive materials with which the interrogating radiation may interact between source and detector. To deal with the many target types and clutter configurations that may be encountered in the field, the use of "artificial templates" is proposed. The MCNP code was used to simulate 14.1 MeV neutron source beams incident on one type of target containing various clutter and sample materials. Signatures due to inelastic-scatter and prompt-capture gamma rays from hydrogen, carbon, nitrogen, and oxygen and two scattered neutron signatures were considered. Targets containing explosive materials in the presence of clutter were able to be identified from targets that contained only non-explosive ("inert") materials. This study demonstrates that a finite number of artificial templates is sufficient for IED detection with fairly good sensitivity and specificity.

  11. Design of a fast echo matching algorithm to reduce crosstalk with Doppler shifts in ultrasonic ranging

    Science.gov (United States)

    Liu, Lei; Guo, Rui; Wu, Jun-an

    2017-02-01

    Crosstalk is a main factor for wrong distance measurement by ultrasonic sensors, and this problem becomes more difficult to deal with under Doppler effects. In this paper, crosstalk reduction with Doppler shifts on small platforms is focused on, and a fast echo matching algorithm (FEMA) is proposed on the basis of chaotic sequences and pulse coding technology, then verified through applying it to match practical echoes. Finally, we introduce how to select both better mapping methods for chaotic sequences, and algorithm parameters for higher achievable maximum of cross-correlation peaks. The results indicate the following: logistic mapping is preferred to generate good chaotic sequences, with high autocorrelation even when the length is very limited; FEMA can not only match echoes and calculate distance accurately with an error degree mostly below 5%, but also generates nearly the same calculation cost level for static or kinematic ranging, much lower than that by direct Doppler compensation (DDC) with the same frequency compensation step; The sensitivity to threshold value selection and performance of FEMA depend significantly on the achievable maximum of cross-correlation peaks, and a higher peak is preferred, which can be considered as a criterion for algorithm parameter optimization under practical conditions.

  12. Fast Fractal Compression of Satellite and Medical Images Based on Domain-Range Entropy

    Directory of Open Access Journals (Sweden)

    Ramesh Babu Inampudi

    2010-01-01

    Full Text Available Fractal image Compression is a lossy compression technique developed in the early 1990s. It makes use of the local self-similarity property existing in an image and finds a contractive mapping affine transformation (fractal transformT, such that the fixed point of T is close to the given image in a suitable metric. It has generated much interest due to its promise of high compression ratios with good decompression quality. The other advantage is its multi resolution property, i.e. an image can be decoded at higher or lower resolutions than the original without much degradation in quality. However, the encoding time is computationally intensive. In this paper, a fast fractal image compression method based on the domain-range entropy is proposed to reduce the encoding time, while maintaining the fidelity and compression ratio of the decoded image. The method is a two-step process. First, domains that are similar i.e. domains having nearly equal variances are eliminated from the domain pool. Second, during the encoding phase, only domains and ranges having equal entropies (with an adaptive error threshold, λdepth for each quadtree depth are compared for a match within the rms error tolerance. As a result, many unqualified domains are removed from comparison and a significant reduction in encoding time is expected. The method is applied for compression of satellite and medical images (512x512, 8-bit gray scale. Experimental results show that the proposed method yields superior performance over Fisher’s classified search and other methods.

  13. Analytically derived limits on short-range fifth forces from quantum states of neutrons in the Earth's gravitational field

    OpenAIRE

    Westphal, Alexander; Abele, Hartmut; Baessler, Stefan

    2007-01-01

    Recently, quantum states of ultra-cold neutrons in the Earth's gravitational field have been observed for the first time. From the fact that they are consistent with Newtonian gravity on the 10 %-level, analytical limits on alpha and lambda of short-range Yukawa-like additional interactions are derived between lambda = 1 micrometer and 1 mm. We arrive for lambda > 10 micrometer at alpha < 2 \\cdot 10^11 at 90 % confidence level. This translates into a limit g_s g_p / (\\hbar c) < 2 \\cdot 10^{-1...

  14. Analytically derived limits on short-range fifth forces from quantum states of neutrons in the Earth's gravitational field

    CERN Document Server

    Westphal, A; Baessler, S; Abele, Hartmut; Baessler, Stefan; Westphal, Alexander

    2007-01-01

    Recently, quantum states of ultra-cold neutrons in the Earth's gravitational field have been observed for the first time. From the fact that they are consistent with Newtonian gravity on the 10 %-level, analytical limits on alpha and lambda of short-range Yukawa-like additional interactions are derived between lambda = 1 micrometer and 1 mm. We arrive for lambda > 10 micrometer at alpha < 2 \\cdot 10^11 at 90 % confidence level. This translates into a limit g_s g_p / (\\hbar c) < 2 \\cdot 10^{-15} on the pseudo-scalar coupling of axions in the previously experimentally unaccessible astrophysical axion window.

  15. Effective-Range Expansion of the Neutron-Deuteron Scattering Studied by a Quark-Model Nonlocal Gaussian Potential

    CERN Document Server

    Fukukawa, Kenji

    2010-01-01

    The S-wave effective range parameters of the neutron-deuteron (nd) scattering are derived in the Faddeev formalism, using a nonlocal Gaussian potential based on the quark-model baryon-baryon interaction fss2. The spin-doublet low-energy eigenphase shift is sufficiently attractive to reproduce predictions by the AV18 plus Urbana three-nucleon force, yielding the observed value of the doublet scattering length and the correct differential cross sections below the deuteron breakup threshold. This conclusion is consistent with the previous result for the triton binding energy, which is nearly reproduced by fss2 without reinforcing it with the three-nucleon force.

  16. Melt-cast organic glasses as high-efficiency fast neutron scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Joseph S.; Feng, Patrick L., E-mail: plfeng@sandia.gov

    2016-10-01

    In this work we report a new class of organic-based scintillators that combines several of the desirable attributes of existing crystalline, liquid, and plastic organic scintillators. The prepared materials may be isolated in single crystalline form or melt-cast to produce highly transparent glasses that have been shown to provide high light yields of up to 16,000 photons/MeVee, as evaluated against EJ-200 plastic scintillators and solution-grown trans-stilbene crystals. The prepared organic glasses exhibit neutron/gamma pulse-shape discrimination (PSD) and are compatible with wavelength shifters to reduce optical self-absorption effects that are intrinsic to pure materials such as crystalline organics. The combination of high scintillation efficiency, PSD capabilities, and facile scale-up via melt-casting distinguishes this new class of amorphous materials from existing alternatives.

  17. MIMAC low energy electron-recoil discrimination measured with fast neutrons

    CERN Document Server

    Riffard, Q; Guillaudin, O; Bosson, G; Bourrion, O; Bouvier, J; Descombes, T; Muraz, J -F; Lebreton, L; Maire, D; Colas, P; Giomataris, I; Busto, J; Fouchez, D; Brunner, J; Tao, C

    2016-01-01

    MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^{5}$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a $10^{5}$ electron rejection power is reached with a 85.1\\% nuclear recoil efficiency using the same detector gain that on the detectors running at Modane.

  18. Influence of nickel and beryllium content on swelling behavior of copper irradiated with fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Singh, B.N.; Garner, F.A.; Edwards, D.J. [Pacific Northwest National Lab., Richland, WA (United States); Evans, J.H.

    1996-10-01

    In the 1970`s, the effects of nickel content on the evolution of dislocation microstructures and the formation and growth of voids in Cu-Ni alloys were studied using 1 MeV electrons in a high voltage electron microscope. The swelling rate was found to decrease rapidly with increasing nickel content. The decrease in the swelling rate was associated with a decreasing void growth rate with increasing nickel content at irradiation temperatures up to 450{degrees}C. At 500{degrees}C, both void size and swelling rate were found to peak at 1 and 2% Ni, respectively, and then to decrease rapidly with increasing nickel content. However, recent work has demonstrated that the swelling behavior of Cu-5%Ni irradiated with fission neutrons is very similar for that of pure copper. The present experiments were designed to investigate this apparent discrepancy.

  19. Determination of nitrogen in wheat flour through Activation analysis using Fast neutron flux of a Thermal nuclear reactor; Determinacion de nitrogeno en harina de trigo mediante analisis por activacion empleando el flujo de neutrones rapidos de un reactor nuclear termico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez G, T

    1976-07-01

    In this work is done a technical study for determining Nitrogen (protein) and other elements in wheat flour Activation analysis, with Fast neutrons from a Thermal nuclear reactor. Initially it is given an introduction about the basic principles of the methods of analysis. Equipment used in Activation analysis and a brief description of the neutron source (Thermal nuclear reactor). The realized experiments for determining the flux form in the irradiation site, the half life of N-13 and the interferences due to the sample composition are included too. Finally, the obtained results by Activation and the Kjeldahl method are tabulated. (Author)

  20. A facility for fast-neutron irradiations at Jyväskylä and its use for nuclide cross-section measurements in fission

    Science.gov (United States)

    Lhersonneau, G.; Malkiewicz, T.; Jones, P.; Karvonen, P.; Ketelhut, S.; Bajeat, O.; Fadil, M.; Gaudu, S.; Saint-Laurent, M. G.; Trzaska, W. H.

    2013-01-01

    An efficient and reliable transport system for fast-neutron irradiations has been built at the Physics Department, Jyväskylä, Finland. It is constructed from commercial bicycle components and is driven by a computer-controlled stepping motor. It can be operated in single or cyclic mode. The neutron irradiated targets are moved within 1.2 s (full stop to full stop) to a well-shielded position 3 m away where they can be removed or directly investigated by γ spectroscopy. The system has been built with the aim to experimentally verify the calculated production rates of neutron-rich nuclei in the SPIRAL2 uranium target. However, the facility can be used for various kinds of fast-neutron irradiations, with a neutron spectrum up to 60 MeV produced by stopping a deuteron beam of several μA in a thick target. Examples of applications are activation and integral cross-section measurements, evaluation of damages in materials and biological cells.