  1. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  2. Adaptive cancellation of motion artifact in wearable biosensors.

    Science.gov (United States)

    Yousefi, Rasoul; Nourani, Mehrdad; Panahi, Issa

    2012-01-01

    The performance of wearable biosensors is highly influenced by motion artifact. In this paper, a model is proposed for analysis of motion artifact in wearable photoplethysmography (PPG) sensors. Using this model, we proposed a robust real-time technique to estimate fundamental frequency and generate a noise reference signal. A Least Mean Square (LMS) adaptive noise canceler is then designed and validated using our synthetic noise generator. The analysis and results on proposed technique for noise cancellation shows promising performance.

  3. Motion Artifact in the MR imaging of temporomandibular disorders

    International Nuclear Information System (INIS)

    Tamamura, Kiyoharu; Miyajima, Hisashi; Nihei, Yoshinobu; Nemoto, Ryuichi; Ohno, Tomoya

    1997-01-01

    Recently, magnetic resonance imaging (MRI) is indispensable for the diagnosis of temporomandibular disorders (TMD). Motion Artifacts of MRI occur more frequently than in other conventional methods, because it takes a long time to obtain the images. This paper reported on Motion Artifacts on MRI. MRI studies of 232 temporomandibular joints were performed in 116 patients with TMD by using a 0.5-T magnetic resonance (MR) scanner, with spin echo sequence: protondensity-weighted. And we took MRI slices at opening phase and closing phase. So 232 slices were gathered and we evaluated clinically the incidence of Motion Artifacts, that is to say, double and multiple images and other factors. The 103 slices in 56 patients showed Motion Artifacts. There is no significant difference between sexes. By age group, those in their teens were most frequent, followed by those in their fifties, forties, thirties and twenties. Also the same results were obtained for double image and multiple image. Incidence of Motion Artifact was most frequent at the opening phase. There is no significant difference between double and multiple image. (author)

  4. Two-dimensional analysis of motion artifacts, including flow effects

    International Nuclear Information System (INIS)

    Litt, A.M.; Brody, A.S.; Spangler, R.A.; Scott, P.D.

    1990-01-01

    The effects of motion on magnetic resonance images have been theoretically analyzed for the case of a point-like object in simple harmonic motion and for other one-dimensional trajectories. The authors of this paper extend this analysis to a generalized two-dimensional magnetization with an arbitrary motion trajectory. The authors provide specific solutions for the clinically relevant cases of the cross-sections of cylindrical objects in the body, such as the aorta, which has a roughly one-dimensional, simple harmonic motion during respiration. By extending the solution to include inhomogeneous magnetizations, the authors present a model which allows the effects of motion artifacts and flow artifacts to be analyzed simultaneously

  5. Motion-induced dose artifacts in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bryan; Chen, Jeff; Battista, Jerry [London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada); Kron, Tomas [Peter MacCallum Cancer Center, Melbourne (Australia)], E-mail: bryan.kim@lhsc.on.ca

    2009-10-07

    Tumor motion is a particular concern for a complex treatment modality such as helical tomotherapy, where couch position, gantry rotation and MLC leaf opening all change with time. In the present study, we have investigated the impact of tumor motion for helical tomotherapy, which could result in three distinct motion-induced dose artifacts, namely (1) dose rounding, (2) dose rippling and (3) IMRT leaf opening asynchronization effect. Dose rounding and dose rippling effects have been previously described, while the IMRT leaf opening asynchronization effect is a newly discovered motion-induced dose artifact. Dose rounding is the penumbral widening of a delivered dose distribution near the edges of a target volume along the direction of tumor motion. Dose rippling is a series of periodic dose peaks and valleys observed within the target region along the direction of couch motion, due to an asynchronous interplay between the couch motion and the longitudinal component of tumor motion. The IMRT leaf opening asynchronization effect is caused by an asynchronous interplay between the temporal patterns of leaf openings and tumor motion. The characteristics of each dose artifact were investigated individually as functions of target motion amplitude and period for both non-IMRT and IMRT helical tomotherapy cases, through computer simulation modeling and experimental verification. The longitudinal dose profiles generated by the simulation program agreed with the experimental data within {+-}0.5% and {+-}1.5% inside the PTV region for the non-IMRT and IMRT cases, respectively. The dose rounding effect produced a penumbral increase up to 20.5 mm for peak-to-peak target motion amplitudes ranging from 1.0 cm to 5.0 cm. Maximum dose rippling magnitude of 25% was calculated, when the target motion period approached an unusually high value of 10 s. The IMRT leaf opening asynchronization effect produced dose differences ranging from -29% to 7% inside the PTV region. This information

  6. Negligible motion artifacts in scalp electroencephalography (EEG during treadmill walking

    Directory of Open Access Journals (Sweden)

    Kevin eNathan

    2016-01-01

    Full Text Available Recent Mobile Brain/Body Imaging (MoBI techniques based on active electrode scalp electroencephalogram (EEG allow the acquisition and real-time analysis of brain dynamics during active unrestrained motor behavior involving whole body movements such as treadmill walking, over-ground walking and other locomotive and non-locomotive tasks. Unfortunately, MoBI protocols are prone to physiological and non-physiological artifacts, including motion artifacts that may contaminate the EEG recordings. A few attempts have been made to quantify these artifacts during locomotion tasks but with inconclusive results due in part to methodological pitfalls. In this paper, we investigate the potential contributions of motion artifacts in scalp EEG during treadmill walking at three different speeds (1.5, 3.0, and 4.5 km/h using a wireless 64 channel active EEG system and a wireless inertial sensor attached to the subject’s head. The experimental setup was designed according to good measurement practices using state-of-the-art commercially-available instruments, and the measurements were analyzed using Fourier analysis and wavelet coherence approaches. Contrary to prior claims, the subjects’ motion did not significantly affect their EEG during treadmill walking although precaution should be taken when gait speeds approach 4.5 km/h. Overall, these findings suggest how MoBI methods may be safely deployed in neural, cognitive, and rehabilitation engineering applications.

  7. Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring

    Directory of Open Access Journals (Sweden)

    Christoph Hoog Antink

    2017-12-01

    Full Text Available Sensors integrated into objects of everyday life potentially allow unobtrusive health monitoring at home. However, since the coupling of sensors and subject is not as well-defined as compared to a clinical setting, the signal quality is much more variable and can be disturbed significantly by motion artifacts. One way of tackling this challenge is the combined evaluation of multiple channels via sensor fusion. For robust and accurate sensor fusion, analyzing the influence of motion on different modalities is crucial. In this work, a multimodal sensor setup integrated into an armchair is presented that combines capacitively coupled electrocardiography, reflective photoplethysmography, two high-frequency impedance sensors and two types of ballistocardiography sensors. To quantify motion artifacts, a motion protocol performed by healthy volunteers is recorded with a motion capture system, and reference sensors perform cardiorespiratory monitoring. The shape-based signal-to-noise ratio SNR S is introduced and used to quantify the effect on motion on different sensing modalities. Based on this analysis, an optimal combination of sensors and fusion methodology is developed and evaluated. Using the proposed approach, beat-to-beat heart-rate is estimated with a coverage of 99.5% and a mean absolute error of 7.9 ms on 425 min of data from seven volunteers in a proof-of-concept measurement scenario.

  8. Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring

    Science.gov (United States)

    Hoog Antink, Christoph; Schulz, Florian; Walter, Marian

    2017-01-01

    Sensors integrated into objects of everyday life potentially allow unobtrusive health monitoring at home. However, since the coupling of sensors and subject is not as well-defined as compared to a clinical setting, the signal quality is much more variable and can be disturbed significantly by motion artifacts. One way of tackling this challenge is the combined evaluation of multiple channels via sensor fusion. For robust and accurate sensor fusion, analyzing the influence of motion on different modalities is crucial. In this work, a multimodal sensor setup integrated into an armchair is presented that combines capacitively coupled electrocardiography, reflective photoplethysmography, two high-frequency impedance sensors and two types of ballistocardiography sensors. To quantify motion artifacts, a motion protocol performed by healthy volunteers is recorded with a motion capture system, and reference sensors perform cardiorespiratory monitoring. The shape-based signal-to-noise ratio SNRS is introduced and used to quantify the effect on motion on different sensing modalities. Based on this analysis, an optimal combination of sensors and fusion methodology is developed and evaluated. Using the proposed approach, beat-to-beat heart-rate is estimated with a coverage of 99.5% and a mean absolute error of 7.9 ms on 425 min of data from seven volunteers in a proof-of-concept measurement scenario. PMID:29295594

  9. Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring.

    Science.gov (United States)

    Hoog Antink, Christoph; Schulz, Florian; Leonhardt, Steffen; Walter, Marian

    2017-12-25

    Sensors integrated into objects of everyday life potentially allow unobtrusive health monitoring at home. However, since the coupling of sensors and subject is not as well-defined as compared to a clinical setting, the signal quality is much more variable and can be disturbed significantly by motion artifacts. One way of tackling this challenge is the combined evaluation of multiple channels via sensor fusion. For robust and accurate sensor fusion, analyzing the influence of motion on different modalities is crucial. In this work, a multimodal sensor setup integrated into an armchair is presented that combines capacitively coupled electrocardiography, reflective photoplethysmography, two high-frequency impedance sensors and two types of ballistocardiography sensors. To quantify motion artifacts, a motion protocol performed by healthy volunteers is recorded with a motion capture system, and reference sensors perform cardiorespiratory monitoring. The shape-based signal-to-noise ratio SNR S is introduced and used to quantify the effect on motion on different sensing modalities. Based on this analysis, an optimal combination of sensors and fusion methodology is developed and evaluated. Using the proposed approach, beat-to-beat heart-rate is estimated with a coverage of 99.5% and a mean absolute error of 7.9 ms on 425 min of data from seven volunteers in a proof-of-concept measurement scenario.

  10. Correcting for motion artifact in handheld laser speckle images

    Science.gov (United States)

    Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard

    2018-03-01

    Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

  11. Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution

    Directory of Open Access Journals (Sweden)

    Zhang Yuan-ting

    2005-03-01

    Full Text Available Abstract Background The pulse oximeter, a medical device capable of measuring blood oxygen saturation (SpO2, has been shown to be a valuable device for monitoring patients in critical conditions. In order to incorporate the technique into a wearable device which can be used in ambulatory settings, the influence of motion artifacts on the estimated SpO2 must be reduced. This study investigates the use of the smoothed psuedo Wigner-Ville distribution (SPWVD for the reduction of motion artifacts affecting pulse oximetry. Methods The SPWVD approach is compared with two techniques currently used in this field, i.e. the weighted moving average (WMA and the fast Fourier transform (FFT approaches. SpO2 and pulse rate were estimated from a photoplethysmographic (PPG signal recorded when subject is in a resting position as well as in the act of performing four types of motions: horizontal and vertical movements of the hand, and bending and pressing motions of the finger. For each condition, 24 sets of PPG signals collected from 6 subjects, each of 30 seconds, were studied with reference to the PPG signal recorded simultaneously from the subject's other hand, which was stationary at all times. Results and Discussion The SPWVD approach shows significant improvement (p Conclusion The results suggested that the SPWVD approach could potentially be used to reduce motion artifact on wearable pulse oximeters.

  12. The relation between respiratory motion artifact correction and lung standardized uptake value

    International Nuclear Information System (INIS)

    Yin Lijie; Liu Xiaojian; Liu Jie; Xu Rui; Yan Jue

    2014-01-01

    PET/CT is playing an important role in disease diagnosis and therapeutic evaluation. But the respiratory motion artifact may bring trouble in diagnosis and therapy. There are many methods to correct the respiratory motion artifact. Respiratory gated PET/CT is applied most extensively of them. Using respiratory gated PET/CT to correct respiratory motion artifact can increase the maximum standardized uptake value of lung lesion obviously, thereby improving the quality of image and accuracy of diagnosis. (authors)

  13. Nuclear magnetic resonance method and apparatus for reducing motion artifacts

    International Nuclear Information System (INIS)

    Bailes, D.R.

    1988-01-01

    A nuclear magnetic resonance apparatus for imaging a region of a body in which part of the region is moving with a motion such that its displacement with respect to time is a nonmonotonic function during a time period over which a plurality of NMR data signals, which together define an image, are collected. The apparatus is described comprising: excitation means arranged to excite nuclear magnetic spins preferentially in the region; encoding means arranged to encode the magnetic spins; data collection means arranged to collect data signals representative of encoded magnetic spins; display means responsive to collected data signals to display an image of the region; measuring means arranged to produce an output indicative of the displacement of the moving part of the region; and control means for controlling the encoding means during the time period in dependence on the output of the measuring means so that data signals collected during the time period are collected in an order dependent on the motion such that motion artifacts are reduced

  14. Photoplethysmograph signal reconstruction based on a novel motion artifact detection-reduction approach. Part II: Motion and noise artifact removal.

    Science.gov (United States)

    Salehizadeh, S M A; Dao, Duy K; Chong, Jo Woon; McManus, David; Darling, Chad; Mendelson, Yitzhak; Chon, Ki H

    2014-11-01

    We introduce a new method to reconstruct motion and noise artifact (MNA) contaminated photoplethysmogram (PPG) data. A method to detect MNA corrupted data is provided in a companion paper. Our reconstruction algorithm is based on an iterative motion artifact removal (IMAR) approach, which utilizes the singular spectral analysis algorithm to remove MNA artifacts so that the most accurate estimates of uncorrupted heart rates (HRs) and arterial oxygen saturation (SpO2) values recorded by a pulse oximeter can be derived. Using both computer simulations and three different experimental data sets, we show that the proposed IMAR approach can reliably reconstruct MNA corrupted data segments, as the estimated HR and SpO2 values do not significantly deviate from the uncorrupted reference measurements. Comparison of the accuracy of reconstruction of the MNA corrupted data segments between our IMAR approach and the time-domain independent component analysis (TD-ICA) is made for all data sets as the latter method has been shown to provide good performance. For simulated data, there were no significant differences in the reconstructed HR and SpO2 values starting from 10 dB down to -15 dB for both white and colored noise contaminated PPG data using IMAR; for TD-ICA, significant differences were observed starting at 10 dB. Two experimental PPG data sets were created with contrived MNA by having subjects perform random forehead and rapid side-to-side finger movements show that; the performance of the IMAR approach on these data sets was quite accurate as non-significant differences in the reconstructed HR and SpO2 were found compared to non-contaminated reference values, in most subjects. In comparison, the accuracy of the TD-ICA was poor as there were significant differences in reconstructed HR and SpO2 values in most subjects. For non-contrived MNA corrupted PPG data, which were collected with subjects performing walking and stair climbing tasks, the IMAR significantly

  15. Motion artifacts in functional near-infrared spectroscopy: a comparison of motion correction techniques applied to real cognitive data

    Science.gov (United States)

    Brigadoi, Sabrina; Ceccherini, Lisa; Cutini, Simone; Scarpa, Fabio; Scatturin, Pietro; Selb, Juliette; Gagnon, Louis; Boas, David A.; Cooper, Robert J.

    2013-01-01

    Motion artifacts are a significant source of noise in many functional near-infrared spectroscopy (fNIRS) experiments. Despite this, there is no well-established method for their removal. Instead, functional trials of fNIRS data containing a motion artifact are often rejected completely. However, in most experimental circumstances the number of trials is limited, and multiple motion artifacts are common, particularly in challenging populations. Many methods have been proposed recently to correct for motion artifacts, including principle component analysis, spline interpolation, Kalman filtering, wavelet filtering and correlation-based signal improvement. The performance of different techniques has been often compared in simulations, but only rarely has it been assessed on real functional data. Here, we compare the performance of these motion correction techniques on real functional data acquired during a cognitive task, which required the participant to speak aloud, leading to a low-frequency, low-amplitude motion artifact that is correlated with the hemodynamic response. To compare the efficacy of these methods, objective metrics related to the physiology of the hemodynamic response have been derived. Our results show that it is always better to correct for motion artifacts than reject trials, and that wavelet filtering is the most effective approach to correcting this type of artifact, reducing the area under the curve where the artifact is present in 93% of the cases. Our results therefore support previous studies that have shown wavelet filtering to be the most promising and powerful technique for the correction of motion artifacts in fNIRS data. The analyses performed here can serve as a guide for others to objectively test the impact of different motion correction algorithms and therefore select the most appropriate for the analysis of their own fNIRS experiment. PMID:23639260

  16. TARGETED PRINCIPLE COMPONENT ANALYSIS: A NEW MOTION ARTIFACT CORRECTION APPROACH FOR NEAR-INFRARED SPECTROSCOPY.

    Science.gov (United States)

    Yücel, Meryem A; Selb, Juliette; Cooper, Robert J; Boas, David A

    2014-03-01

    As near-infrared spectroscopy (NIRS) broadens its application area to different age and disease groups, motion artifacts in the NIRS signal due to subject movement is becoming an important challenge. Motion artifacts generally produce signal fluctuations that are larger than physiological NIRS signals, thus it is crucial to correct for them before obtaining an estimate of stimulus evoked hemodynamic responses. There are various methods for correction such as principle component analysis (PCA), wavelet-based filtering and spline interpolation. Here, we introduce a new approach to motion artifact correction, targeted principle component analysis (tPCA), which incorporates a PCA filter only on the segments of data identified as motion artifacts. It is expected that this will overcome the issues of filtering desired signals that plagues standard PCA filtering of entire data sets. We compared the new approach with the most effective motion artifact correction algorithms on a set of data acquired simultaneously with a collodion-fixed probe (low motion artifact content) and a standard Velcro probe (high motion artifact content). Our results show that tPCA gives statistically better results in recovering hemodynamic response function (HRF) as compared to wavelet-based filtering and spline interpolation for the Velcro probe. It results in a significant reduction in mean-squared error (MSE) and significant enhancement in Pearson's correlation coefficient to the true HRF. The collodion-fixed fiber probe with no motion correction performed better than the Velcro probe corrected for motion artifacts in terms of MSE and Pearson's correlation coefficient. Thus, if the experimental study permits, the use of a collodion-fixed fiber probe may be desirable. If the use of a collodion-fixed probe is not feasible, then we suggest the use of tPCA in the processing of motion artifact contaminated data.

  17. TARGETED PRINCIPLE COMPONENT ANALYSIS: A NEW MOTION ARTIFACT CORRECTION APPROACH FOR NEAR-INFRARED SPECTROSCOPY

    Science.gov (United States)

    YÜCEL, MERYEM A.; SELB, JULIETTE; COOPER, ROBERT J.; BOAS, DAVID A.

    2014-01-01

    As near-infrared spectroscopy (NIRS) broadens its application area to different age and disease groups, motion artifacts in the NIRS signal due to subject movement is becoming an important challenge. Motion artifacts generally produce signal fluctuations that are larger than physiological NIRS signals, thus it is crucial to correct for them before obtaining an estimate of stimulus evoked hemodynamic responses. There are various methods for correction such as principle component analysis (PCA), wavelet-based filtering and spline interpolation. Here, we introduce a new approach to motion artifact correction, targeted principle component analysis (tPCA), which incorporates a PCA filter only on the segments of data identified as motion artifacts. It is expected that this will overcome the issues of filtering desired signals that plagues standard PCA filtering of entire data sets. We compared the new approach with the most effective motion artifact correction algorithms on a set of data acquired simultaneously with a collodion-fixed probe (low motion artifact content) and a standard Velcro probe (high motion artifact content). Our results show that tPCA gives statistically better results in recovering hemodynamic response function (HRF) as compared to wavelet-based filtering and spline interpolation for the Velcro probe. It results in a significant reduction in mean-squared error (MSE) and significant enhancement in Pearson’s correlation coefficient to the true HRF. The collodion-fixed fiber probe with no motion correction performed better than the Velcro probe corrected for motion artifacts in terms of MSE and Pearson’s correlation coefficient. Thus, if the experimental study permits, the use of a collodion-fixed fiber probe may be desirable. If the use of a collodion-fixed probe is not feasible, then we suggest the use of tPCA in the processing of motion artifact contaminated data. PMID:25360181

  18. Investigating the possible effect of electrode support structure on motion artifact in wearable bioelectric signal monitoring.

    Science.gov (United States)

    Cömert, Alper; Hyttinen, Jari

    2015-05-15

    With advances in technology and increasing demand, wearable biosignal monitoring is developing and new applications are emerging. One of the main challenges facing the widespread use of wearable monitoring systems is the motion artifact. The sources of the motion artifact lie in the skin-electrode interface. Reducing the motion and deformation at this interface should have positive effects on signal quality. In this study, we aim to investigate whether the structure supporting the electrode can be designed to reduce the motion artifact with the hypothesis that this can be achieved by stabilizing the skin deformations around the electrode. We compare four textile electrodes with different support structure designs: a soft padding larger than the electrode area, a soft padding larger than the electrode area with a novel skin deformation restricting design, a soft padding the same size as the electrode area, and a rigid support the same size as the electrode. With five subjects and two electrode locations placed over different kinds of tissue at various mounting forces, we simultaneously measured the motion artifact, a motion affected ECG, and the real-time skin-electrode impedance during the application of controlled motion to the electrodes. The design of the electrode support structure has an effect on the generated motion artifact; good design with a skin stabilizing structure makes the electrodes physically more motion artifact resilient, directly affecting signal quality. Increasing the applied mounting force shows a positive effect up to 1,000 gr applied force. The properties of tissue under the electrode are an important factor in the generation of the motion artifact and the functioning of the electrodes. The relationship of motion artifact amplitude to the electrode movement magnitude is seen to be linear for smaller movements. For larger movements, the increase of motion generated a disproportionally larger artifact. The motion artifact and the induced

  19. A robust post-processing workflow for datasets with motion artifacts in diffusion kurtosis imaging.

    Science.gov (United States)

    Li, Xianjun; Yang, Jian; Gao, Jie; Luo, Xue; Zhou, Zhenyu; Hu, Yajie; Wu, Ed X; Wan, Mingxi

    2014-01-01

    The aim of this study was to develop a robust post-processing workflow for motion-corrupted datasets in diffusion kurtosis imaging (DKI). The proposed workflow consisted of brain extraction, rigid registration, distortion correction, artifacts rejection, spatial smoothing and tensor estimation. Rigid registration was utilized to correct misalignments. Motion artifacts were rejected by using local Pearson correlation coefficient (LPCC). The performance of LPCC in characterizing relative differences between artifacts and artifact-free images was compared with that of the conventional correlation coefficient in 10 randomly selected DKI datasets. The influence of rejected artifacts with information of gradient directions and b values for the parameter estimation was investigated by using mean square error (MSE). The variance of noise was used as the criterion for MSEs. The clinical practicality of the proposed workflow was evaluated by the image quality and measurements in regions of interest on 36 DKI datasets, including 18 artifact-free (18 pediatric subjects) and 18 motion-corrupted datasets (15 pediatric subjects and 3 essential tremor patients). The relative difference between artifacts and artifact-free images calculated by LPCC was larger than that of the conventional correlation coefficient (pworkflow improved the image quality and reduced the measurement biases significantly on motion-corrupted datasets (pworkflow was reliable to improve the image quality and the measurement precision of the derived parameters on motion-corrupted DKI datasets. The workflow provided an effective post-processing method for clinical applications of DKI in subjects with involuntary movements.

  20. Induction and separation of motion artifacts in EEG data using a mobile phantom head device.

    Science.gov (United States)

    Oliveira, Anderson S; Schlink, Bryan R; Hairston, W David; König, Peter; Ferris, Daniel P

    2016-06-01

    Electroencephalography (EEG) can assess brain activity during whole-body motion in humans but head motion can induce artifacts that obfuscate electrocortical signals. Definitive solutions for removing motion artifact from EEG have yet to be found, so creating methods to assess signal processing routines for removing motion artifact are needed. We present a novel method for investigating the influence of head motion on EEG recordings as well as for assessing the efficacy of signal processing approaches intended to remove motion artifact. We used a phantom head device to mimic electrical properties of the human head with three controlled dipolar sources of electrical activity embedded in the phantom. We induced sinusoidal vertical motions on the phantom head using a custom-built platform and recorded EEG signals with three different acquisition systems while the head was both stationary and in varied motion conditions. Recordings showed up to 80% reductions in signal-to-noise ratio (SNR) and up to 3600% increases in the power spectrum as a function of motion amplitude and frequency. Independent component analysis (ICA) successfully isolated the three dipolar sources across all conditions and systems. There was a high correlation (r > 0.85) and marginal increase in the independent components' (ICs) power spectrum (∼15%) when comparing stationary and motion parameters. The SNR of the IC activation was 400%-700% higher in comparison to the channel data SNR, attenuating the effects of motion on SNR. Our results suggest that the phantom head and motion platform can be used to assess motion artifact removal algorithms and compare different EEG systems for motion artifact sensitivity. In addition, ICA is effective in isolating target electrocortical events and marginally improving SNR in relation to stationary recordings.

  1. A systematic comparison of motion artifact correction techniques for functional near-infrared spectroscopy.

    Science.gov (United States)

    Cooper, Robert J; Selb, Juliette; Gagnon, Louis; Phillip, Dorte; Schytz, Henrik W; Iversen, Helle K; Ashina, Messoud; Boas, David A

    2012-01-01

    Near-infrared spectroscopy (NIRS) is susceptible to signal artifacts caused by relative motion between NIRS optical fibers and the scalp. These artifacts can be very damaging to the utility of functional NIRS, particularly in challenging subject groups where motion can be unavoidable. A number of approaches to the removal of motion artifacts from NIRS data have been suggested. In this paper we systematically compare the utility of a variety of published NIRS motion correction techniques using a simulated functional activation signal added to 20 real NIRS datasets which contain motion artifacts. Principle component analysis, spline interpolation, wavelet analysis, and Kalman filtering approaches are compared to one another and to standard approaches using the accuracy of the recovered, simulated hemodynamic response function (HRF). Each of the four motion correction techniques we tested yields a significant reduction in the mean-squared error (MSE) and significant increase in the contrast-to-noise ratio (CNR) of the recovered HRF when compared to no correction and compared to a process of rejecting motion-contaminated trials. Spline interpolation produces the largest average reduction in MSE (55%) while wavelet analysis produces the highest average increase in CNR (39%). On the basis of this analysis, we recommend the routine application of motion correction techniques (particularly spline interpolation or wavelet analysis) to minimize the impact of motion artifacts on functional NIRS data.

  2. Correction of computed tomography motion artifacts using pixel-specific back-projection

    International Nuclear Information System (INIS)

    Ritchie, C.J.; Crawford, C.R.; Godwin, J.D.; Kim, Y. King, K.F.

    1996-01-01

    Cardiac and respiratory motion can cause artifacts in computed tomography scans of the chest. The authors describe a new method for reducing these artifacts called pixel-specific back-projection (PSBP). PSBP reduces artifacts caused by in-plane motion by reconstructing each pixel in a frame of reference that moves with the in-plane motion in the volume being scanned. The motion of the frame of reference is specified by constructing maps that describe the motion of each pixel in the image at the time each projection was measured; these maps are based on measurements of the in-plane motion. PSBP has been tested in computer simulations and with volunteer data. In computer simulations, PSBP removed the structured artifacts caused by motion. In scans of two volunteers, PSBP reduced doubling and streaking in chest scans to a level that made the images clinically useful. PSBP corrections of liver scans were less satisfactory because the motion of the liver is predominantly superior-inferior (S-I). PSBP uses a unique set of motion parameters to describe the motion at each point in the chest as opposed to requiring that the motion be described by a single set of parameters. Therefore, PSBP may be more useful in correcting clinical scans than are other correction techniques previously described

  3. Improving pulse oximetry accuracy by removing motion artifacts from photoplethysmograms using relative sensor motion: a preliminary study

    NARCIS (Netherlands)

    Wijshoff, R.W.C.G.R.; Mischi, M.; Woerlee, P.H.; Aarts, R.M.; Van Huffel, S.; Naelaers, G.; Caicedo, A.; Bruley, D.F.; Harrison, D.K.

    2013-01-01

    To expand applicability of pulse oximetry in low-acuity ambulatory settings, the impact of motion on extracted parameters as saturation (SpO2) and pulse rate (PR) needs to be reduced. We hypothesized that sensor motion relative to the skin can be used as an artifact reference in a correlation

  4. Temporal interpolation alters motion in fMRI scans: Magnitudes and consequences for artifact detection.

    Directory of Open Access Journals (Sweden)

    Jonathan D Power

    Full Text Available Head motion can be estimated at any point of fMRI image processing. Processing steps involving temporal interpolation (e.g., slice time correction or outlier replacement often precede motion estimation in the literature. From first principles it can be anticipated that temporal interpolation will alter head motion in a scan. Here we demonstrate this effect and its consequences in five large fMRI datasets. Estimated head motion was reduced by 10-50% or more following temporal interpolation, and reductions were often visible to the naked eye. Such reductions make the data seem to be of improved quality. Such reductions also degrade the sensitivity of analyses aimed at detecting motion-related artifact and can cause a dataset with artifact to falsely appear artifact-free. These reduced motion estimates will be particularly problematic for studies needing estimates of motion in time, such as studies of dynamics. Based on these findings, it is sensible to obtain motion estimates prior to any image processing (regardless of subsequent processing steps and the actual timing of motion correction procedures, which need not be changed. We also find that outlier replacement procedures change signals almost entirely during times of motion and therefore have notable similarities to motion-targeting censoring strategies (which withhold or replace signals entirely during times of motion.

  5. Characterization and reduction of motion artifacts in photoplethysmographic signals from a wrist-worn device

    NARCIS (Netherlands)

    Tauţan, A.M.; Young, A.; Wentink, E.; Wieringa, F.P.

    2015-01-01

    Methods for analyzing various motion artifacts in photoplethysmography (PPG) signals, recorded by a wristworn device are reported. The analysis looks both at intrinsic PPG signal properties, through standard deviation, skew and kurtosis, but also at its relationship to five possible motion reference

  6. Biased motion vector interpolation for reduced video artifacts.

    NARCIS (Netherlands)

    2011-01-01

    In a video processing system where motion vectors are estimated for a subset of the blocks of data forming a video frame, and motion vectors are interpolated for the remainder of the blocks of the frame, a method includes determining, for at least at least one block of the current frame for which a

  7. Correction of Motion Artifacts for Real-Time Structured Light

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Paulsen, Rasmus Reinhold

    2015-01-01

    While the problem of motion is often mentioned in conjunction with structured light imaging, few solutions have thus far been proposed. A method is demonstrated to correct for object or camera motion during structured light 3D scene acquisition. The method is based on the combination of a suitabl...

  8. Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging

    International Nuclear Information System (INIS)

    Lavdas, E.; Zaloni, E.; Vlychou, M.; Vassiou, K.; Fezoulidis, I.; Tsagkalis, A.; Dailiana, Z.

    2015-01-01

    To evaluate the ability of proton-density with fat-suppression BLADE (proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction in MR systems from Siemens Healthcare, PDFS BLADE) and turbo inversion recovery magnitude-BLADE (TIRM BLADE) sequences to reduce motion and pulsation artifacts in shoulder magnetic resonance examinations. Forty-one consecutive patients who had been routinely scanned for shoulder examination participated in the study. The following pairs of sequences with and without BLADE were compared: (a) Oblique coronal proton-density sequence with fat saturation of 25 patients and (b) oblique sagittal T2 TIRM-weighed sequence of 20 patients. Qualitative analysis was performed by two experienced radiologists. Image motion and pulsation artifacts were also evaluated. In oblique coronal PDFS BLADE sequences, motion artifacts have been significantly eliminated, even in five cases of non-diagnostic value with conventional imaging. Similarly, in oblique sagittal T2 TIRM BLADE sequences, image quality has been improved, even in six cases of non-diagnostic value with conventional imaging. Furthermore, flow artifacts have been improved in more than 80% of all the cases. The use of BLADE sequences is recommended in shoulder imaging, especially in uncooperative patients because it effectively eliminates motion and pulsation artifacts. (orig.)

  9. Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study

    Science.gov (United States)

    Werner, René; Gauer, Tobias

    2015-03-01

    Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.

  10. Artifacts

    Science.gov (United States)

    Harris, Samantha

    2009-01-01

    NASA Headquarters sent a list of items to KSC that were deemed potential artifacts. These items played arole in the Shuttle Program's development and maintenance. Because these items are national assets, many are of interest to museums, schools, other government entities, etc. upon the Space Shuttle's retirement. The list contains over 500 items. All of these items need to be located, photographed, and catalogued with accompanying specific data that needs to be gathered. Initial research suggests that this is a time, labor, and cost intensive project. The purpose of my project was to focus on 20-60 of these 500 items, gather the necessary data, and compile them in a way that can be added to by other users when/if the project goes into full effect.

  11. MuSeSe - A multisensor armchair for unobtrusive vital sign estimation and motion artifact analysis.

    Science.gov (United States)

    Antink, Christoph Hoog; Leonhardt, Steffen; Schulz, Florian; Walter, Marian

    2017-07-01

    Unobtrusive vital sign estimation with sensors integrated into objects of everyday living can substantially advance the field of remote monitoring. At the same time, motion artifacts cause severe problems and have to be dealt with. Here, the fusion of multimodal sensor data is a promising approach. In this paper, we present an armchair equipped with capacitively coupled electrocardiogram, two types of ballistocardiographic sensors, photoplethysmographic and two high-frequency impedance sensors. In addition, a video-based sensor for motion analysis is integrated. Using a defined motion protocol, the feasibility of the system is demonstrated in a self-experimentation. Moreover, the influence of different movements on different modalities is analyzed. Finally, robust beat-to-beat interval estimation demonstrates the benefits of multimodal sensor fusion for vital sign estimation in the presence of motion artifacts.

  12. Experimental analysis of motion artifacts in chest radiographs with the AMBER system

    International Nuclear Information System (INIS)

    Boetticher, H. von; Hofmann, K.; Luska, G.

    1999-01-01

    The prerequisites, mechanisms and principles of motion artifacts in AMBER radiographs were analysed. The experiments were performed using metronomes, a moving conventional mammography phantom, and arrangements of oscillating coil spring, spheroid and grid elements. A diagnostic dosimeter and TLDs, respectively, were used to measure exposure times and doses. The deree of distortion in AMBER radiographs depends on the direction of the object movement relative to the AMBER fan beam in a complex manner. The size of the motion artifacts depends on the local exposure time. The maximum value of this time is 75 ms and thus 1.5 times higher than specified by the manufacturer. To interpret AMBER radiographs possible system specific artifacts have to be considered to avoid misinterpretations of potentially significant details. (orig.) [de

  13. Effect of motion artifacts and their correction on near-infrared spectroscopy oscillation data

    DEFF Research Database (Denmark)

    Selb, Juliette; Yücel, Meryem A; Phillip, Dorte

    2015-01-01

    Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which...... in the frequency band around 0.1 and 0.04 Hz, suggesting a physiological origin for the difference. We emphasize the importance of considering MAs as a confounding factor in oscillation-based functional near-infrared spectroscopy studies....

  14. sEMG during Whole-Body Vibration Contains Motion Artifacts and Reflex Activity

    Directory of Open Access Journals (Sweden)

    Karin Lienhard

    2015-01-01

    Full Text Available The purpose of this study was to determine whether the excessive spikes observed in the surface electromyography (sEMG spectrum recorded during whole-body vibration (WBV exercises contain motion artifacts and/or reflex activity. The occurrence of motion artifacts was tested by electrical recordings of the patella. The involvement of reflex activity was investigated by analyzing the magnitude of the isolated spikes during changes in voluntary background muscle activity. Eighteen physically active volunteers performed static squats while the sEMG was measured of five lower limb muscles during vertical WBV using no load and an additional load of 33 kg. In order to record motion artifacts during WBV, a pair of electrodes was positioned on the patella with several layers of tape between skin and electrodes. Spectral analysis of the patella signal revealed recordings of motion artifacts as high peaks at the vibration frequency (fundamental and marginal peaks at the multiple harmonics were observed. For the sEMG recordings, the root mean square of the spikes increased with increasing additional loads (p < 0.05, and was significantly correlated to the sEMG signal without the spikes of the respective muscle (r range: 0.54 - 0.92, p < 0.05. This finding indicates that reflex activity might be contained in the isolated spikes, as identical behavior has been found for stretch reflex responses evoked during direct vibration. In conclusion, the spikes visible in the sEMG spectrum during WBV exercises contain motion artifacts and possibly reflex activity.

  15. A novel algorithm to separate motion artifacts from photoplethysmographic signals obtained with a reflectance pulse oximeter.

    Science.gov (United States)

    Yao, Jianchu; Warren, Steve

    2004-01-01

    Pulse oximeters are mainstays for acquiring blood oxygen saturation in static environments such as hospital rooms. However, motion artifacts prevent their broad in wearable, ambulatory environments. To this end, we present a novel algorithm to separate the motion artifacts from plethysmographic data gathered by pulse oximeters. This algorithm, based on the Beer-Lambert law, requires photoplethysmographic data acquired at three excitation wavelengths. The algorithm can calculate venous blood oxygen saturation (SvO2) as well as arterial blood oxygen saturation (SaO2). Preliminary results indicate that the extraction of the venous signal, which is assumed to be most affected by motions, is successful with data acquired from a reflectance-mode sensor.

  16. Automatic identification of motion artifacts in EHG recording for robust analysis of uterine contractions.

    Science.gov (United States)

    Ye-Lin, Yiyao; Garcia-Casado, Javier; Prats-Boluda, Gema; Alberola-Rubio, José; Perales, Alfredo

    2014-01-01

    Electrohysterography (EHG) is a noninvasive technique for monitoring uterine electrical activity. However, the presence of artifacts in the EHG signal may give rise to erroneous interpretations and make it difficult to extract useful information from these recordings. The aim of this work was to develop an automatic system of segmenting EHG recordings that distinguishes between uterine contractions and artifacts. Firstly, the segmentation is performed using an algorithm that generates the TOCO-like signal derived from the EHG and detects windows with significant changes in amplitude. After that, these segments are classified in two groups: artifacted and nonartifacted signals. To develop a classifier, a total of eleven spectral, temporal, and nonlinear features were calculated from EHG signal windows from 12 women in the first stage of labor that had previously been classified by experts. The combination of characteristics that led to the highest degree of accuracy in detecting artifacts was then determined. The results showed that it is possible to obtain automatic detection of motion artifacts in segmented EHG recordings with a precision of 92.2% using only seven features. The proposed algorithm and classifier together compose a useful tool for analyzing EHG signals and would help to promote clinical applications of this technique.

  17. Automatic Identification of Motion Artifacts in EHG Recording for Robust Analysis of Uterine Contractions

    Directory of Open Access Journals (Sweden)

    Yiyao Ye-Lin

    2014-01-01

    Full Text Available Electrohysterography (EHG is a noninvasive technique for monitoring uterine electrical activity. However, the presence of artifacts in the EHG signal may give rise to erroneous interpretations and make it difficult to extract useful information from these recordings. The aim of this work was to develop an automatic system of segmenting EHG recordings that distinguishes between uterine contractions and artifacts. Firstly, the segmentation is performed using an algorithm that generates the TOCO-like signal derived from the EHG and detects windows with significant changes in amplitude. After that, these segments are classified in two groups: artifacted and nonartifacted signals. To develop a classifier, a total of eleven spectral, temporal, and nonlinear features were calculated from EHG signal windows from 12 women in the first stage of labor that had previously been classified by experts. The combination of characteristics that led to the highest degree of accuracy in detecting artifacts was then determined. The results showed that it is possible to obtain automatic detection of motion artifacts in segmented EHG recordings with a precision of 92.2% using only seven features. The proposed algorithm and classifier together compose a useful tool for analyzing EHG signals and would help to promote clinical applications of this technique.

  18. A systematic comparison of motion artifact correction techniques for functional near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Cooper, Robert J; Selb, Juliette; Gagnon, Louis

    2012-01-01

    a significant reduction in the mean-squared error (MSE) and significant increase in the contrast-to-noise ratio (CNR) of the recovered HRF when compared to no correction and compared to a process of rejecting motion-contaminated trials. Spline interpolation produces the largest average reduction in MSE (55....... Principle component analysis, spline interpolation, wavelet analysis, and Kalman filtering approaches are compared to one another and to standard approaches using the accuracy of the recovered, simulated hemodynamic response function (HRF). Each of the four motion correction techniques we tested yields......%) while wavelet analysis produces the highest average increase in CNR (39%). On the basis of this analysis, we recommend the routine application of motion correction techniques (particularly spline interpolation or wavelet analysis) to minimize the impact of motion artifacts on functional NIRS data....

  19. Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study.

    Science.gov (United States)

    Farshad-Amacker, Nadja A; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas

    2013-10-01

    To evaluate the potential of high-pitch, dual-source computed tomography (DSCT) for compensation of motion artifacts. Motion artifacts were created using a moving chest/cardiac phantom with integrated stents at different velocities (from 0 to 4-6 cm/s) parallel (z direction), transverse (x direction), and diagonal (x and z direction combined) to the scanning direction using standard-pitch (SP) (pitch = 1) and high-pitch (HP) (pitch = 3.2) 128-detector DSCT (Siemens, Healthcare, Forchheim, Germany). The scanning parameters were (SP/HP): tube voltage, 120 kV/120 kV; effective tube current time product, 300 mAs/500 mAs; and a pitch of 1/3.2. Motion artifacts were analyzed in terms of subjective image quality and object distortion. Image quality was rated by two blinded, independent observers using a 4-point scoring system (1, excellent; 2, good with minor object distortion or blurring; 3, diagnostically partially not acceptable; and 4, diagnostically not acceptable image quality). Object distortion was assessed by the measured changes of the object's outer diameter (x) and length (z) and a corresponding calculated distortion vector (d) (d = √(x(2) + z(2))). The interobserver agreement was excellent (k = 0.91). Image quality using SP was diagnostically not acceptable with any motion in x direction (scores 3 and 4), in contrast to HP DSCT where it remained diagnostic up to 2 cm/s (scores 1 and 2). For motion in the z direction only, image quality remained diagnostic for SP and HP DSCT (scores 1 and 2). Changes of the object's diameter (x), length (z), and distortion vectors (d) were significantly greater with SP (overall: x = 1.9 cm ± 1.7 cm, z = 0.6 cm ± 0.8 cm, and d = 1.4 cm ± 1.5 cm) compared to HP DSCT (overall: x = 0.1 cm ± 0.1 cm, z = 0.0 cm ± 0.1 cm, and d = 0.1 cm ± 0.1 cm; each P pitch DSCT significantly decreases motion artifacts in various directions and improves image quality. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  20. Effect of subcutaneous butylscopolamine administration in the reduction of peristaltic artifacts in 1.5-T MR fast abdominal examinations

    International Nuclear Information System (INIS)

    Dosda, Rosa; Marti-Bonmati, Luis; Molla, Enrique; Arana, Estanislao; Ronchera-Oms, Crisanto L.

    2003-01-01

    In abdominal MR imaging, ghost artifacts from noncyclic bowel movements can reduce the quality of the images. Although pharmacologic suppression of motion is effective, no study has being conducted to analyze the influence of drug motion suppression on fast breath-hold 1.5-T examinations of the upper abdomen. A prospective, randomized, double-blind trial was conducted in 50 patients. Patients were randomly distributed into two groups: The control group received only an oral solution, whereas the other group received the oral solution plus a subcutaneous injection of 20 mg of butylscopolamine 10 min before the MR examination. Breath-hold T1-weighted gradient-recalled-echo (GRE) MR images were obtained in a 1.5-T superconductive unit. Quantitative image analysis was performed with region-of-interest (ROI) measurements of the signal intensity of the liver and in background air anterior and lateral to the patient. A qualitative analysis of the subjective quality of the T1-weighted images was also done, and the adverse reactions were registered. The groups were homogeneous regarding age, gender, and weight distribution. No significant differences in the signal intensity of the liver and in the incoherent noise measurements were found between the two groups. Gastrointestinal noise showed significant differences between groups, with lower values for the butylscopolamine group compared with the control group. There was also a statistically significant difference in the image quality between groups, and optimal studies were only found in the butylscopolamine group, where most patients had a good-quality evaluation. Regarding adverse events, there were non-significant differences between groups. In conclusion, administration of an antiperistaltic agent to reduce the movements of the gastrointestinal tract diminishes the motion artifacts generated on MR imaging of the abdomen, even at high field strength and with fast imaging sequences. Images of the upper abdomen obtained

  1. Reduction of motion artifacts for PET imaging by respiratory correlated dynamic scanning

    International Nuclear Information System (INIS)

    Chuang, K.-S.; Chen, T.-J.; Chang, C.-C.; Wu, J.; Chen, S.; Wu, L.-C.; Liu, R.-S.

    2006-01-01

    Organ motion caused by respiration is a major challenge in positron emission tomography (PET) imaging. This work proposes a technique to reduce smearing in PET imaging caused by respiratory motion. Dynamic scanning at 1 frame/s is used. A point source, used as a marker, is attached to the object's abdomen during the scan. The source position in the projection view moves with respiratory motion and can be used to represent the respiratory phase within the time interval in which each frame data are acquired. One hundred and twenty frames are obtained for each study. The range of the positions of the marker is divided into four groups, representing different respiratory phases. The frames in which the organ positions (phases) are the same summed to produce a static sub-sinogram. Each sub-sinogram then undergoes regular image reconstruction to yield a motion-free image. The technique is applied to one volunteer under both free and coached breathing conditions. A parameter called the volume reduction factor is adopted to evaluate the effectiveness of this motion-reduction technique. The preliminary results indicate that the proposed technique effectively reduces motion artifacts in the image. Coached breathing yields better results than free breathing condition. The advantages of this method are that (1) the scanning time remains the same; (2) free breathing is allowed during the acquisition of the image; and (3) no user intervention is required

  2. A short study to assess the potential of independent component analysis for motion artifact separation in wearable pulse oximeter signals.

    Science.gov (United States)

    Yao, Jianchu; Warren, Steve

    2005-01-01

    Motion artifact reduction and separation become critical when medical sensors are used in wearable monitoring scenarios. Previous research has demonstrated that independent component analysis (ICA) can be applied to pulse oximeter signals to separate photoplethysmographic (PPG) data from motion artifacts, ambient light, and other interference in low-motion environments. However, ICA assumes that all source signal component pairs are mutually independent. It is important to assess the statistical independence of the source components in PPG data, especially if ICA is to be applied in ambulatory monitoring environments, where motion artifacts can have a substantial effect on the quality of data received from light-based sensors. This paper addresses the statistical relationship between motion artifacts and PPG data by calculating the correlation coefficients between arterial volume variations and motion over a range of stationary to high-motion conditions. Analyses indicate that motion significantly affects arterial flow, so care must be taken when applying ICA to light-based sensor data acquired from wearable platforms.

  3. Correction of head motion artifacts in SPECT with fully 3-D OS-EM reconstruction

    International Nuclear Information System (INIS)

    Fulton, R.R.

    1998-01-01

    Full text: A method which relies on continuous monitoring of head position has been developed to correct for head motion in SPECT studies of the brain. Head position and orientation are monitored during data acquisition by an inexpensive head tracking system (ADL-1, Shooting Star Technology, Rosedale, British Colombia). Motion correction involves changing the projection geometry to compensate for motion (using data from the head tracker), and reconstructing with a fully 3-D OS-EM algorithm. The reconstruction algorithm can accommodate any number of movements and any projection geometry. A single iteration of 3-D OS-EM using all available projections provides a satisfactory 3-D reconstruction, essentially free of motion artifacts. The method has been validated in studies of the 3-D Hoffman brain phantom. Multiple 36- degree acquisitions, each with the phantom in a different position, were performed on a Trionix triple head camera. Movements were simulated by combining projections from the different acquisitions. Accuracy was assessed by comparison with a motion-free reconstruction, visually and by calculating mean squared error (MSE). Motion correction reduced distortion perceptibly and, depending on the motions applied, improved MSE by up to an order of magnitude. Three-dimensional reconstruction of the 128 x 128 x 128 data set took 2- minutes on a SUN Ultra 1 workstation. This motion correction technique can be retro-fitted to existing SPECT systems and could be incorporated in future SPECT camera designs. It appears to be applicable in PET as well as SPECT, to be able to correct for any head movements, and to have the potential to improve the accuracy of tomographic brain studies under clinical imaging conditions

  4. Transient severe respiratory motion artifacts after application of gadoxetate disodium. What we currently know

    International Nuclear Information System (INIS)

    Well, Lennart; Weinrich, Julius Matthias; Adam, Gerhard; Bannas, Peter

    2018-01-01

    Gadoxetate disodium is an intracellular contrast agent for magnetic resonance imaging (MRI) of the liver. Recent publications revealed that injection of gadoxetate disodium can lead to imaging artifacts due to transient severe motion (TSM) in the arterial phase of contrast-enhanced liver MRI. In this review we present and discuss published frequencies of TSM, contrast injection and image acquisition protocols, potential risk factors, and proposed strategies to avoid or minimize the effects of TSM. Two reviewers independently searched the PubMed search engine for ''transient severe motion artifact'' and related terms. Reference lists of retrieved articles were also searched. The two reviewers selected in consensus nine studies that reported both frequencies of TSM and potential risk factors. Study data were extracted by both reviewers, and disagreement was resolved by consensus. TSM is caused by impaired breath-hold ability after gadoxetate disodium injection and occurs in 5 -22% of patients. The dose of applied contrast agent, repeated exposure to gadoxetate disodium, high BMI and pulmonary disease have been described as potential risk factors for TSM. However, there are only few concordant results on this topic and the pathophysiology of TSM has not been identified. Proposed strategies for the prevention of TSM are slow injection rates and low doses of diluted gadoxetate disodium. Accelerated and free-breathing MRI sequence protocols and breath-hold training may minimize the effects of TSM. Further prospective studies are needed to confirm these strategies and to identify the underlying mechanism of TSM.

  5. Transient severe respiratory motion artifacts after application of gadoxetate disodium. What we currently know

    Energy Technology Data Exchange (ETDEWEB)

    Well, Lennart; Weinrich, Julius Matthias; Adam, Gerhard; Bannas, Peter [Univ. Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology and Nuclear Medicince

    2018-01-15

    Gadoxetate disodium is an intracellular contrast agent for magnetic resonance imaging (MRI) of the liver. Recent publications revealed that injection of gadoxetate disodium can lead to imaging artifacts due to transient severe motion (TSM) in the arterial phase of contrast-enhanced liver MRI. In this review we present and discuss published frequencies of TSM, contrast injection and image acquisition protocols, potential risk factors, and proposed strategies to avoid or minimize the effects of TSM. Two reviewers independently searched the PubMed search engine for ''transient severe motion artifact'' and related terms. Reference lists of retrieved articles were also searched. The two reviewers selected in consensus nine studies that reported both frequencies of TSM and potential risk factors. Study data were extracted by both reviewers, and disagreement was resolved by consensus. TSM is caused by impaired breath-hold ability after gadoxetate disodium injection and occurs in 5 -22% of patients. The dose of applied contrast agent, repeated exposure to gadoxetate disodium, high BMI and pulmonary disease have been described as potential risk factors for TSM. However, there are only few concordant results on this topic and the pathophysiology of TSM has not been identified. Proposed strategies for the prevention of TSM are slow injection rates and low doses of diluted gadoxetate disodium. Accelerated and free-breathing MRI sequence protocols and breath-hold training may minimize the effects of TSM. Further prospective studies are needed to confirm these strategies and to identify the underlying mechanism of TSM.

  6. Quality control of structural MRI images applied using FreeSurfer - a hands-on workflow to rate motion artifacts

    Directory of Open Access Journals (Sweden)

    Lea Luise Backhausen

    2016-12-01

    Full Text Available In structural magnetic resonance imaging motion artifacts are common, especially when not scanning healthy young adults. It has been shown that motion affects the analysis with automated image-processing techniques (e.g. FreeSurfer. This can bias results. Several developmental and adult studies have found reduced volume and thickness of gray matter due to motion artifacts. Thus, quality control is necessary in order to ensure an acceptable level of quality and to define exclusion criteria of images (i.e. determine participants with most severe artifacts. However, information about the quality control workflow and image exclusion procedure is largely lacking in the current literature and the existing rating systems differ. Here we propose a stringent workflow of quality control steps during and after acquisition of T1-weighted images, which enables researchers dealing with populations that are typically affected by motion artifacts to enhance data quality and maximize sample sizes. As an underlying aim we established a thorough quality control rating system for T1-weighted images and applied it to the analysis of developmental clinical data using the automated processing pipeline FreeSurfer. This hands-on workflow and quality control rating system will aid researchers in minimizing motion artifacts in the final data set, and therefore enhance the quality of structural magnetic resonance imaging studies.

  7. The reduction of motion artifacts in digital subtraction angiography by geometrical image transformation

    International Nuclear Information System (INIS)

    Fitzpatrick, J.M.; Pickens, D.R.; Mandava, V.R.; Grefenstette, J.J.

    1988-01-01

    In the diagnosis of arteriosclerosis, radio-opaque dye is injected into the interior of the arteries to make them visible. Because of its increased contrast sensitivity, digital subtraction angiography has the potential for providing diagnostic images of arteries with reduced dye volumes. In the conventional technique, a mask image, acquired before the introduction of the dye, is subtracted from the contrast image, acquired after the dye is introduced, to produce a difference image in which only the dye in the arteries is visible. The usefulness of this technique has been severely limited by the image degradation caused by patient motion during image acquisition. This motion produces artifacts in the difference image that obscure the arteries. One technique for dealing with the problem is to reduce the degradation by means of image registration. The registration is carried out by means of a geometrical transformation of the mask image before subtraction so that it is in registration with the contrast image. This paper describes a technique for determining an optimal transformation. The authors employ a one-to-one elastic mapping and the Jacobian of that mapping to produce a geometrical image transformation. They choose a parameterized class of such mappings and use a heuristic search algorithm to optimize the parameters to minimize the severity of the motion artifacts. To increase the speed of the optimization process they use a statistical image comparison technique that provides a quick approximate evaluation of each image transformation. They present the experimental results of the application of their registration system to mask-contrast pairs, for images acquired from a specially designed phantom, and for clinical images

  8. Mitigation of motion artifacts in CBCT of lung tumors based on tracked tumor motion during CBCT acquisition

    International Nuclear Information System (INIS)

    Lewis, John H; Li Ruijiang; Jia Xun; Watkins, W Tyler; Song, William Y; Jiang, Steve B; Lou, Yifei

    2011-01-01

    An algorithm capable of mitigating respiratory motion blurring artifacts in cone-beam computed tomography (CBCT) lung tumor images based on the motion of the tumor during the CBCT scan is developed. The tumor motion trajectory and probability density function (PDF) are reconstructed from the acquired CBCT projection images using a recently developed algorithm Lewis et al (2010 Phys. Med. Biol. 55 2505-22). Assuming that the effects of motion blurring can be represented by convolution of the static lung (or tumor) anatomy with the motion PDF, a cost function is defined, consisting of a data fidelity term and a total variation regularization term. Deconvolution is performed through iterative minimization of this cost function. The algorithm was tested on digital respiratory phantom, physical respiratory phantom and patient data. A clear qualitative improvement is evident in the deblurred images as compared to the motion-blurred images for all cases. Line profiles show that the tumor boundaries are more accurately and clearly represented in the deblurred images. The normalized root-mean-squared error between the images used as ground truth and the motion-blurred images are 0.29, 0.12 and 0.30 in the digital phantom, physical phantom and patient data, respectively. Deblurring reduces the corresponding values to 0.13, 0.07 and 0.19. Application of a -700 HU threshold to the digital phantom results in tumor dimension measurements along the superior-inferior axis of 2.8, 1.8 and 1.9 cm in the motion-blurred, ground truth and deblurred images, respectively. Corresponding values for the physical phantom are 3.4, 2.7 and 2.7 cm. A threshold of -500 HU applied to the patient case gives measurements of 3.1, 1.6 and 1.7 cm along the SI axis in the CBCT, 4DCT and deblurred images, respectively. This technique could provide more accurate information about a lung tumor's size and shape on the day of treatment.

  9. Please Don't Move-Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features.

    Science.gov (United States)

    Rantalainen, Timo; Chivers, Paola; Beck, Belinda R; Robertson, Sam; Hart, Nicolas H; Nimphius, Sophia; Weeks, Benjamin K; McIntyre, Fleur; Hands, Beth; Siafarikas, Aris

    Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01-0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans. Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  10. Transient severe motion artifact related to gadoxetate disodium-enhanced liver MRI. Frequency and risk evaluation at a German institution

    Energy Technology Data Exchange (ETDEWEB)

    Well, Lennart; Rausch, Vanessa Hanna; Adam, Gerhard; Henes, Frank Oliver; Bannas, Peter [Univ. Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. for Diagnostic and Interventional Radiology and Nuclear Medicine

    2017-07-15

    Varying frequencies (5 - 18%) of contrast-related transient severe motion (TSM) imaging artifacts during gadoxetate disodium-enhanced arterial phase liver MRI have been reported. Since previous reports originated from the United States and Japan, we aimed to determine the frequency of TSM at a German institution and to correlate it with potential risk factors and previously published results. Two age- and sex-matched groups were retrospectively selected (gadoxetate disodium n = 89; gadobenate dimeglumine n = 89) from dynamic contrast-enhanced MRI examinations in a single center. Respiratory motion-related artifacts in non-enhanced and dynamic phases were assessed independently by two readers blinded to contrast agents on a 4-point scale. Scores of ≥3 were considered as severe motion artifacts. Severe motion artifacts in arterial phases were considered as TSM if scores in all other phases were < 3. Potential risk factors for TSM were evaluated via logistic regression analysis. For gadoxetate disodium, the mean score for respiratory motion artifacts was significantly higher in the arterial phase (2.2 ± 0.9) compared to all other phases (1.6 ± 0.7) (p < 0.05). The frequency of TSM was significantly higher with gadoxetate disodium (n = 19; 21.1 %) than with gadobenate dimeglumine (n = 1; 1.1%) (p < 0.001). The frequency of TSM at our institution is similar to some, but not all previously published findings. Logistic regression analysis did not show any significant correlation between TSM and risk factors (all p>0.05). We revealed a high frequency of TSM after injection of gadoxetate disodium at a German institution, substantiating the importance of a diagnosis-limiting phenomenon that so far has only been reported from the United States and Japan. In accordance with previous studies, we did not identify associated risk factors for TSM.

  11. Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity

    Energy Technology Data Exchange (ETDEWEB)

    Li, Guang, E-mail: lig2@mskcc.org; Caraveo, Marshall [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Wei, Jie [Department of Computer Science, City College of New York, New York, New York 10031 (United States); Rimner, Andreas; Wu, Abraham J.; Goodman, Karyn A. [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Yorke, Ellen [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York 10065 (United States)

    2014-11-01

    Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largest five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ{sup ¯}, defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MAS{sup D} is normalized to the maximum diaphragmatic displacement and MAS{sup V} is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value

  12. Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity

    International Nuclear Information System (INIS)

    Li, Guang; Caraveo, Marshall; Wei, Jie; Rimner, Andreas; Wu, Abraham J.; Goodman, Karyn A.; Yorke, Ellen

    2014-01-01

    Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largest five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ ¯ , defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MAS D is normalized to the maximum diaphragmatic displacement and MAS V is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value ranging from 0

  13. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

    International Nuclear Information System (INIS)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-01-01

    Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same

  14. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT.

    Science.gov (United States)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-03-01

    The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used

  15. Real-Time Correction By Optical Tracking with Integrated Geometric Distortion Correction for Reducing Motion Artifacts in fMRI

    Science.gov (United States)

    Rotenberg, David J.

    Artifacts caused by head motion are a substantial source of error in fMRI that limits its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and non-linear spin-history artifacts, however residual artifacts due to dynamic magnetic field non-uniformity may remain in the data. A recently developed correction technique, PLACE, can correct for absolute geometric distortion using the complex image data from two EPI images, with slightly shifted k-space trajectories. We present a correction approach that integrates PLACE into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an fMRI finger tapping experiment with overt head motion to induce dynamic field non-uniformity. Experiments suggest that including volume by volume geometric distortion correction by PLACE can suppress dynamic geometric distortion artifacts in a phantom and in vivo and provide more robust activation maps.

  16. A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series

    Science.gov (United States)

    Patel, Ameera X.; Kundu, Prantik; Rubinov, Mikail; Jones, P. Simon; Vértes, Petra E.; Ersche, Karen D.; Suckling, John; Bullmore, Edward T.

    2014-01-01

    The impact of in-scanner head movement on functional magnetic resonance imaging (fMRI) signals has long been established as undesirable. These effects have been traditionally corrected by methods such as linear regression of head movement parameters. However, a number of recent independent studies have demonstrated that these techniques are insufficient to remove motion confounds, and that even small movements can spuriously bias estimates of functional connectivity. Here we propose a new data-driven, spatially-adaptive, wavelet-based method for identifying, modeling, and removing non-stationary events in fMRI time series, caused by head movement, without the need for data scrubbing. This method involves the addition of just one extra step, the Wavelet Despike, in standard pre-processing pipelines. With this method, we demonstrate robust removal of a range of different motion artifacts and motion-related biases including distance-dependent connectivity artifacts, at a group and single-subject level, using a range of previously published and new diagnostic measures. The Wavelet Despike is able to accommodate the substantial spatial and temporal heterogeneity of motion artifacts and can consequently remove a range of high and low frequency artifacts from fMRI time series, that may be linearly or non-linearly related to physical movements. Our methods are demonstrated by the analysis of three cohorts of resting-state fMRI data, including two high-motion datasets: a previously published dataset on children (N = 22) and a new dataset on adults with stimulant drug dependence (N = 40). We conclude that there is a real risk of motion-related bias in connectivity analysis of fMRI data, but that this risk is generally manageable, by effective time series denoising strategies designed to attenuate synchronized signal transients induced by abrupt head movements. The Wavelet Despiking software described in this article is freely available for download at www

  17. A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series.

    Science.gov (United States)

    Patel, Ameera X; Kundu, Prantik; Rubinov, Mikail; Jones, P Simon; Vértes, Petra E; Ersche, Karen D; Suckling, John; Bullmore, Edward T

    2014-07-15

    The impact of in-scanner head movement on functional magnetic resonance imaging (fMRI) signals has long been established as undesirable. These effects have been traditionally corrected by methods such as linear regression of head movement parameters. However, a number of recent independent studies have demonstrated that these techniques are insufficient to remove motion confounds, and that even small movements can spuriously bias estimates of functional connectivity. Here we propose a new data-driven, spatially-adaptive, wavelet-based method for identifying, modeling, and removing non-stationary events in fMRI time series, caused by head movement, without the need for data scrubbing. This method involves the addition of just one extra step, the Wavelet Despike, in standard pre-processing pipelines. With this method, we demonstrate robust removal of a range of different motion artifacts and motion-related biases including distance-dependent connectivity artifacts, at a group and single-subject level, using a range of previously published and new diagnostic measures. The Wavelet Despike is able to accommodate the substantial spatial and temporal heterogeneity of motion artifacts and can consequently remove a range of high and low frequency artifacts from fMRI time series, that may be linearly or non-linearly related to physical movements. Our methods are demonstrated by the analysis of three cohorts of resting-state fMRI data, including two high-motion datasets: a previously published dataset on children (N=22) and a new dataset on adults with stimulant drug dependence (N=40). We conclude that there is a real risk of motion-related bias in connectivity analysis of fMRI data, but that this risk is generally manageable, by effective time series denoising strategies designed to attenuate synchronized signal transients induced by abrupt head movements. The Wavelet Despiking software described in this article is freely available for download at www

  18. Detection of motion artifacts in optical coherence tomography using the fundus enhancement system

    International Nuclear Information System (INIS)

    Schaudig, U.; Skevas, C.; Scholz, F.

    2007-01-01

    Extensive artefacts due to major eye movements are detectable in optical coherence tomography images (OCT), but frequency and extent of small eye movements have not been studied. To investigate frequency and extent of irregularities in OCT imaging due to eye movements during the scanning process in OCT. A fundus enhancement system (FES) originally designed to improve retinal image quality in a conventional OCT device (Zeiss Stratus OCT) in order to integrate OCT images into fluorescence angiographies was used to record the scanning process and review OCT-scan acquisition in slow motion. A horizontal and a vertical single line scan of 5 mm length through the center of fixation were obtained in 40 eyes of 20 normal healthy subjects, all with a visual acuity of at least 20/20. Scans were investigated for loss of fixation and eye movements during the scanning process. Outcome measures were presence or absence of eye movements during the scanning process and mean deviation from the intended scan position, measured in millimeter. 7 of 20 patients showed no eye movements in both eyes. 4 of the remaining 13 patients showed eye movements only in one eye. In the eyes with detectable movements, the mean deviation from the intended scan position was 0.2 mm in the horizontal and 0.28 mm in the vertical scans. Fundus imaging in conventional systems can be enhanced to detect artifacts due to minimal eye movements during the scanning process. In this first series with normal healthy subjects, minimal eye movements were present in the over half of the investigations. Although the distances from the intended scan positions seem to be small in normal eyes, further investigations of the phenomenon are necessary. OCT is increasingly used as the primary tool for controlling therapy in macular diseases and the extent of motion artefacts is not known. (author) [de

  19. Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a German Institution.

    Science.gov (United States)

    Well, Lennart; Rausch, Vanessa Hanna; Adam, Gerhard; Henes, Frank Oliver; Bannas, Peter

    2017-07-01

    Purpose  Varying frequencies (5 - 18 %) of contrast-related transient severe motion (TSM) imaging artifacts during gadoxetate disodium-enhanced arterial phase liver MRI have been reported. Since previous reports originated from the United States and Japan, we aimed to determine the frequency of TSM at a German institution and to correlate it with potential risk factors and previously published results. Materials and Methods  Two age- and sex-matched groups were retrospectively selected (gadoxetate disodium n = 89; gadobenate dimeglumine n = 89) from dynamic contrast-enhanced MRI examinations in a single center. Respiratory motion-related artifacts in non-enhanced and dynamic phases were assessed independently by two readers blinded to contrast agents on a 4-point scale. Scores of ≥ 3 were considered as severe motion artifacts. Severe motion artifacts in arterial phases were considered as TSM if scores in all other phases were risk factors for TSM were evaluated via logistic regression analysis. Results  For gadoxetate disodium, the mean score for respiratory motion artifacts was significantly higher in the arterial phase (2.2 ± 0.9) compared to all other phases (1.6 ± 0.7) (p risk factors (all p > 0.05). Conclusion  We revealed a high frequency of TSM after injection of gadoxetate disodium at a German institution, substantiating the importance of a diagnosis-limiting phenomenon that so far has only been reported from the United States and Japan. In accordance with previous studies, we did not identify associated risk factors for TSM. Key Points:   · Gadoxetate disodium causes TSM in a relevant number of patients.. · The frequency of TSM is similar between the USA, Japan and Germany.. · To date, no validated risk factors for TSM could be identified.. Citation Format · Well L, Rausch VH, Adam G et al. Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a

  20. Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis

    International Nuclear Information System (INIS)

    Couceiro, R; Carvalho, P; Paiva, R P; Henriques, J; Muehlsteff, J

    2014-01-01

    The presence of motion artifacts in photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular parameters in continuous monitoring applications. In the current paper we present an algorithm for motion artifact detection based on the analysis of the variations in the time and the period domain characteristics of the PPG signal. The extracted features are ranked using a normalized mutual information feature selection algorithm and the best features are used in a support vector machine classification model to distinguish between clean and corrupted sections of the PPG signal. The proposed method has been tested in healthy and cardiovascular diseased volunteers, considering 11 different motion artifact sources. The results achieved by the current algorithm (sensitivity—SE: 84.3%, specificity—SP: 91.5% and accuracy—ACC: 88.5%) show that the current methodology is able to identify both corrupted and clean PPG sections with high accuracy in both healthy (ACC: 87.5%) and cardiovascular diseases (ACC: 89.5%) context. (paper)

  1. A comparative evaluation of adaptive noise cancellation algorithms for minimizing motion artifacts in a forehead-mounted wearable pulse oximeter.

    Science.gov (United States)

    Comtois, Gary; Mendelson, Yitzhak; Ramuka, Piyush

    2007-01-01

    Wearable physiological monitoring using a pulse oximeter would enable field medics to monitor multiple injuries simultaneously, thereby prioritizing medical intervention when resources are limited. However, a primary factor limiting the accuracy of pulse oximetry is poor signal-to-noise ratio since photoplethysmographic (PPG) signals, from which arterial oxygen saturation (SpO2) and heart rate (HR) measurements are derived, are compromised by movement artifacts. This study was undertaken to quantify SpO2 and HR errors induced by certain motion artifacts utilizing accelerometry-based adaptive noise cancellation (ANC). Since the fingers are generally more vulnerable to motion artifacts, measurements were performed using a custom forehead-mounted wearable pulse oximeter developed for real-time remote physiological monitoring and triage applications. This study revealed that processing motion-corrupted PPG signals by least mean squares (LMS) and recursive least squares (RLS) algorithms can be effective to reduce SpO2 and HR errors during jogging, but the degree of improvement depends on filter order. Although both algorithms produced similar improvements, implementing the adaptive LMS algorithm is advantageous since it requires significantly less operations.

  2. SU-F-J-117: Impact of Motion Artifacts On Image Quality and Accuracy of Tumor Motion Reconstruction in 4D CT-On-Rails and MV-CBCT Scans: A Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To compare and quantify respiratory motion artifacts in images from free breathing 4D-CT-on-Rails(CTOR) and those from MV-Cone-beam-CT(MVCB) and facilitate respiratory motion guided radiation therapy. Methods: 4D-CTOR: Siemens Somatom CT-on-Rails system with Anzai belt loaded with pressure sensor load cells. 4D scans were performed in helical mode, pitch 0.1, gantry rotation time 0.5s, 1.5mm slice thickness, 120kVp, 400 mAs. Normal and fast breathing (>12rpm) scanning protocols were investigated. Helical scan, AIP(average intensity projection) and MIP(maximum intensity projection) were generated from 4D-CTOR scans with amplitude sorting into 10 phases.MVCB: Siemens Artiste diamond view(1MV)MVCB was performed with 5MU thorax protocol with 60 second of full rotation.Phantom: Anzai AZ-733V respiratory phantom. The settings were set to normal and resp. modes with repetition rates at 15 rpm and 10 rpm. Surgical clips, acrylic, wooden, rubber and lung density, total six mock-ups were scanned and compared in this study.Signal-to-noise ratio(SNR), contrast-to-noise ratio(CNR) and reconstructed motion volume were compared to different respiratory setups for the mock-ups. Results: Reconstructed motion volume was compared to the real object volume for the six test mock-ups. It shows that free breathing helical in all instances underestimates the object excursions largest to −67.4% and least −6.3%. Under normal breathing settings, MIP can predict very precise motion volume with minimum 0.4% and largest −13.9%. MVCB shows underestimate of the motion volume with −1.11% minimum and −18.0% maximum. With fast breathing, AIP provides bad representation of the object motion; however, the MIP can predict the motion volume with −2.0% to −11.4% underestimate. Conclusion: Respiratory motion guided radiation therapy requires good motion recording. This study shows that regular CTOR helical scans provides bad guidance, 4D CTOR AIP cannot represent the fast breathing

  3. A standardized evaluation of artifacts from metallic compounds during fast MR imaging

    DEFF Research Database (Denmark)

    Murakami, Shumei; Verdonschot, Rinus G; Kataoka, Miyoshi

    2016-01-01

    according to the ASTM-F2119 standard and artifact volumes were assessed using OsiriX MD software Results: Tukey-Kramer post-hoc tests were used for statistical comparisons. For most materials, scanning sequences eliciting artifact volumes in the following (ascending) order FSE-T1/FSE-T2

  4. Fast image interpolation for motion estimation using graphics hardware

    Science.gov (United States)

    Kelly, Francis; Kokaram, Anil

    2004-05-01

    Motion estimation and compensation is the key to high quality video coding. Block matching motion estimation is used in most video codecs, including MPEG-2, MPEG-4, H.263 and H.26L. Motion estimation is also a key component in the digital restoration of archived video and for post-production and special effects in the movie industry. Sub-pixel accurate motion vectors can improve the quality of the vector field and lead to more efficient video coding. However sub-pixel accuracy requires interpolation of the image data. Image interpolation is a key requirement of many image processing algorithms. Often interpolation can be a bottleneck in these applications, especially in motion estimation due to the large number pixels involved. In this paper we propose using commodity computer graphics hardware for fast image interpolation. We use the full search block matching algorithm to illustrate the problems and limitations of using graphics hardware in this way.

  5. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo; Daimon, Tadahisa; Honda, Osamu; Mihara, Naoki; Johkoh, Takeshi; Nakamura, Hironobu

    2009-01-01

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61-0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma

  6. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Daimon, Tadahisa [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Mihara, Naoki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Radiology, Osaka Advanced Medical Imaging Center, 5-20-1 Momoyamadai, Suita-city, Osaka 565-0854 (Japan); Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2009-01-15

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, {kappa} = 0.61-0.71), and fair or poor in the other evaluations ({kappa} < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of

  7. Reduction of respiratory ghosting motion artifacts in conventional two-dimensional multi-slice Cartesian turbo spin-echo: which k-space filling order is the best?

    Science.gov (United States)

    Inoue, Yuuji; Yoneyama, Masami; Nakamura, Masanobu; Takemura, Atsushi

    2018-06-01

    The two-dimensional Cartesian turbo spin-echo (TSE) sequence is widely used in routine clinical studies, but it is sensitive to respiratory motion. We investigated the k-space orders in Cartesian TSE that can effectively reduce motion artifacts. The purpose of this study was to demonstrate the relationship between k-space order and degree of motion artifacts using a moving phantom. We compared the degree of motion artifacts between linear and asymmetric k-space orders. The actual spacing of ghost artifacts in the asymmetric order was doubled compared with that in the linear order in the free-breathing situation. The asymmetric order clearly showed less sensitivity to incomplete breath-hold at the latter half of the imaging period. Because of the actual number of partitions of the k-space and the temporal filling order, the asymmetric k-space order of Cartesian TSE was superior to the linear k-space order for reduction of ghosting motion artifacts.

  8. TU-F-BRB-02: Motion Artifacts and Suppression in MRI

    International Nuclear Information System (INIS)

    Zhong, X.

    2015-01-01

    The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant

  9. TU-F-BRB-02: Motion Artifacts and Suppression in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, X. [Siemens (Germany)

    2015-06-15

    The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

  10. Quantitative fuel motion determination with the CABRI fast neutron hodoscope

    International Nuclear Information System (INIS)

    Baumung, K.; Augier, G.

    1991-01-01

    The fast neutron hodoscope installed at the CABRI reactor in Cadarache, France, is employed to provide quantitative fuel motion data during experiments in which single liquid-metal fast breeder reactor test pins are subjected to simulated accident conditions. Instrument design and performance are reviewed, the methods for the quantitative evaluation are presented, and error sources are discussed. The most important findings are the axial expansion as a function of time, phenomena related to pin failure (such as time, location, pin failure mode, and fuel mass ejected after failure), and linear fuel mass distributions with a 2-cm axial resolution. In this paper the hodoscope results of the CABRI-1 program are summarized

  11. Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging.

    Science.gov (United States)

    Zhou, Ruixi; Huang, Wei; Yang, Yang; Chen, Xiao; Weller, Daniel S; Kramer, Christopher M; Kozerke, Sebastian; Salerno, Michael

    2018-02-01

    SSIM (p simple and robust rigid motion compensation strategy greatly reduces motion artifacts and improves image quality for standard k-t PCA and k-t SLR techniques in setting of respiratory motion due to imperfect breath-holding.

  12. Reduction of thoracic aorta motion artifact with high-pitch 128-slice dual-source computed tomographic angiography: a historical control study.

    Science.gov (United States)

    Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi

    2013-01-01

    Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.

  13. A trial to reduce cardiac motion artifact on HR-CT images of the lung with the use of subsecond scan and special cine reconstruction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Fumikazu; Tsuuchi, Yasuhiko; Suzuki, Keiko; Ueno, Keiko; Yamada, Takayuki; Okawa, Tomohiko [Tokyo Women`s Medical Coll. (Japan); Yun, Shen; Horiuchi, Tetsuya; Kimura, Fumiko

    1998-05-01

    We describe our trial to reduce cardiac motion artifacts on HR-CT images caused by cardiac pulsation by combining use of subsecond CT (scan time 0.8 s) and a special cine reconstruction algorithm (cine reconstruction algorithm with 180-degree helical interpolation). Eleven to 51 HR-CT images were reconstructed with the special cine reconstruction algorithm at the pitch of 0.1 (0.08 s) from the data obtained by two to six contigious rotation scans at the same level. Images with the fewest cardiac motion artifacts were selected for evaluation. These images were compared with those reconstructed with a conventional cine reconstruction algorithm and step-by-step scan. In spite of its increased radiation exposure, technical complexity and slight degradation of spatial resolution, our method was useful in reducing cardiac motion artifacts on HR-CT images in regions adjacent to the heart. (author)

  14. SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Mavroidis, P [University of Texas Health Science Center, UTHSCSA, San Antonio, TX (United States); Lavdas, E; Kostopoulos, S; Ninos, C; Strikou, A; Glotsos, D; Vlachopoulou, A; Oikonomou, G [Technological Education Institute of Athens, Athens, Athens (Greece); Economopoulos, N [General University Hospital ATTIKON, Athens, Athens (Greece); Roka, V [Health Center of Farkadona, Trikala (Greece); Sakkas, G [Center for Research and Technology of Thessaly, Trikala (Greece); Tsagkalis, A; Batsikas, G [IASO Thessalias Hospital, Larissa (Greece); Statkahis, S [Cancer Therapy and Research Center, San Antonio, TX (United States); Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States)

    2014-06-01

    Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved.

  15. SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

    International Nuclear Information System (INIS)

    Mavroidis, P; Lavdas, E; Kostopoulos, S; Ninos, C; Strikou, A; Glotsos, D; Vlachopoulou, A; Oikonomou, G; Economopoulos, N; Roka, V; Sakkas, G; Tsagkalis, A; Batsikas, G; Statkahis, S; Papanikolaou, N

    2014-01-01

    Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved

  16. Regularly incremented phase encoding - MR fingerprinting (RIPE-MRF) for enhanced motion artifact suppression in preclinical cartesian MR fingerprinting.

    Science.gov (United States)

    Anderson, Christian E; Wang, Charlie Y; Gu, Yuning; Darrah, Rebecca; Griswold, Mark A; Yu, Xin; Flask, Chris A

    2018-04-01

    The regularly incremented phase encoding-magnetic resonance fingerprinting (RIPE-MRF) method is introduced to limit the sensitivity of preclinical MRF assessments to pulsatile and respiratory motion artifacts. As compared to previously reported standard Cartesian-MRF methods (SC-MRF), the proposed RIPE-MRF method uses a modified Cartesian trajectory that varies the acquired phase-encoding line within each dynamic MRF dataset. Phantoms and mice were scanned without gating or triggering on a 7T preclinical MRI scanner using the RIPE-MRF and SC-MRF methods. In vitro phantom longitudinal relaxation time (T 1 ) and transverse relaxation time (T 2 ) measurements, as well as in vivo liver assessments of artifact-to-noise ratio (ANR) and MRF-based T 1 and T 2 mean and standard deviation, were compared between the two methods (n = 5). RIPE-MRF showed significant ANR reductions in regions of pulsatility (P Reson Med 79:2176-2182, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Optimized statistical parametric mapping procedure for NIRS data contaminated by motion artifacts : Neurometric analysis of body schema extension.

    Science.gov (United States)

    Suzuki, Satoshi

    2017-09-01

    This study investigated the spatial distribution of brain activity on body schema (BS) modification induced by natural body motion using two versions of a hand-tracing task. In Task 1, participants traced Japanese Hiragana characters using the right forefinger, requiring no BS expansion. In Task 2, participants performed the tracing task with a long stick, requiring BS expansion. Spatial distribution was analyzed using general linear model (GLM)-based statistical parametric mapping of near-infrared spectroscopy data contaminated with motion artifacts caused by the hand-tracing task. Three methods were utilized in series to counter the artifacts, and optimal conditions and modifications were investigated: a model-free method (Step 1), a convolution matrix method (Step 2), and a boxcar-function-based Gaussian convolution method (Step 3). The results revealed four methodological findings: (1) Deoxyhemoglobin was suitable for the GLM because both Akaike information criterion and the variance against the averaged hemodynamic response function were smaller than for other signals, (2) a high-pass filter with a cutoff frequency of .014 Hz was effective, (3) the hemodynamic response function computed from a Gaussian kernel function and its first- and second-derivative terms should be included in the GLM model, and (4) correction of non-autocorrelation and use of effective degrees of freedom were critical. Investigating z-maps computed according to these guidelines revealed that contiguous areas of BA7-BA40-BA21 in the right hemisphere became significantly activated ([Formula: see text], [Formula: see text], and [Formula: see text], respectively) during BS modification while performing the hand-tracing task.

  18. Evaluation and reduction of respiratory motion artifacts in small animal SPECT with GATE

    International Nuclear Information System (INIS)

    Lee, C.-L.; Park, S.-J.; Kim, H.-J.

    2015-01-01

    The degradation of image quality caused by respiration is a major impediment to accurate lesion detection in single photon emission computed tomography (SPECT) imaging. This study was performed to evaluate the effects of lung motion on image quantification. A small animal SPECT system with NaI(Tl) was modeled in the Geant4 application for tomographic emission (GATE) simulation for a lung lesion using a 4D mouse whole-body phantom. SPECT images were obtained using 120 projection views acquired from 0 o to 360 o with a 3 o step. Slices were reconstructed using ordered subsets expectation maximization (OS-EM) without attenuation correction with five iterations and four subsets. Image quality was compared between the static mode without respiratory motion, and dynamic mode with respiratory motion in terms of spatial resolution was measured by the full width at half maximum (FWHM), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The FWHM of the non-gated image and the respiratory gated image were also compared. Spatial resolution improved as activity increased and lesion diameter decreased in the static and dynamic modes. The SNR and CNR increased significantly as lesion activity increased and lesion diameter decreased. Our results show that respiratory motion leads to reduced contrast and quantitative accuracy and that image quantification depends on both the amplitude and the pattern of the respiratory motion. We verified that respiratory motion can have a major effect on the accuracy of measurement of lung lesions and that respiratory gating can reduce activity smearing on SPECT images

  19. Evaluation of soft-tissue artifacts when using anatomical and technical markers to measure mandibular motion

    Directory of Open Access Journals (Sweden)

    Chien-Chih Chen

    2011-06-01

    Conclusions: It appears that markers on the frontal nose bridge are good alternatives to transoral rigid devices for measuring mandibular motion, compared to optical frame markers and other skin markers on the face. The results of the current study will be helpful for establishing guidelines for marker placement when measuring mandibular movements in patients with potential temporomandibular disorders.

  20. Effects of Maternal Valium Administration on Fetal MRI Motion Artifact: A Comparison Study at High Altitude.

    Science.gov (United States)

    Meyers, Mariana L; Mirsky, David M; Dannull, Kimberly A; Tong, Suhong; Crombleholme, Timothy M

    2017-01-01

    Fetal MRI is performed without sedation. In cases of maternal claustrophobia or when reduction of fetal motion is critical, benzodiazepines may help. The purpose of this study was to evaluate the effects of low-dose benzodiazepine on fetal motion MRI and its effect on maternal oxygen levels at higher elevation. A total of 131 fetal MRI scans performed from March 2012 through December 2013 were studied. Nineteen of the cases were performed following Valium administration. Images were graded with a 5-point Likert scale. Using pulse oximetry, maternal oxygen levels were recorded. Results were analyzed for each category combining 3 readers' interpretations. Using a 2-sample t test model, the average imaging scores were better for the control than the Valium group (p = 0.0139). Maternal oxygen levels at different times and positions were compared using independent 2-sample t test between the Valium and control groups showing no change in O2 saturation, except when controlling for altitude and gestational age (p = 0.0326). Administration of low-dose Valium did not decrease fetal motion on MRI. Valium did not pose any risk of maternal hypoxemia, except when controlling for altitude and gestational age on supine position. Thus, caution should be exercised to prevent the risk of fetal hypoxemia. © 2016 S. Karger AG, Basel.

  1. MOTION ARTIFACT REDUCTION IN FUNCTIONAL NEAR INFRARED SPECTROSCOPY SIGNALS BY AUTOREGRESSIVE MOVING AVERAGE MODELING BASED KALMAN FILTERING

    Directory of Open Access Journals (Sweden)

    MEHDI AMIAN

    2013-10-01

    Full Text Available Functional near infrared spectroscopy (fNIRS is a technique that is used for noninvasive measurement of the oxyhemoglobin (HbO2 and deoxyhemoglobin (HHb concentrations in the brain tissue. Since the ratio of the concentration of these two agents is correlated with the neuronal activity, fNIRS can be used for the monitoring and quantifying the cortical activity. The portability of fNIRS makes it a good candidate for studies involving subject's movement. The fNIRS measurements, however, are sensitive to artifacts generated by subject's head motion. This makes fNIRS signals less effective in such applications. In this paper, the autoregressive moving average (ARMA modeling of the fNIRS signal is proposed for state-space representation of the signal which is then fed to the Kalman filter for estimating the motionless signal from motion corrupted signal. Results are compared to the autoregressive model (AR based approach, which has been done previously, and show that the ARMA models outperform AR models. We attribute it to the richer structure, containing more terms indeed, of ARMA than AR. We show that the signal to noise ratio (SNR is about 2 dB higher for ARMA based method.

  2. Combination of fat saturation and variable bandwidth imaging to increase signal-to-noise ratio and decrease motion artifacts for body MR imaging at high field

    International Nuclear Information System (INIS)

    Chew, W.M.

    1989-01-01

    The signal-to-noise ratio (SNR) of the MR imaging examination is a critical component of the quality of the image. Standard methods to increase SNR include signal averaging with multiple excitations, at the expense of imaging time (which on T2-weighted images could be quite significant), or increasing pixel volume by manipulation of field of view, matrix size, and/or section thickness, all at the expense of resolution. Another available method to increase SNR is to reduce the bandwidth of the receiver, which increases SNR by the square root of the amount of the reduction. The penalty imposed on high-field-strength MR examinations of the body is an unacceptable increase in chemical shift artifact. However, presaturating the fat resonance eliminates the chemical shift artifact. Thus, a combination of imaging techniques, fat suppression, and decreased bandwidth imaging can produce images free of chemical shift artifact with increased SNR and no penalty in resolution or imaging time. Early studies also show a reduction in motion artifact when fat saturation is used. This paper reports MR imaging performed with a 1.5-T Signa imager. With this technique, T2-weighted images (2,500/20/80 [repetition time msec/echo time msec/inversion time msec]) illustrating the increase in SNR and T1-weighted images (600/20) demonstrating a decrease in motion artifact are shown

  3. Estimating actigraphy from motion artifacts in ECG and respiratory effort signals.

    Science.gov (United States)

    Fonseca, Pedro; Aarts, Ronald M; Long, Xi; Rolink, Jérôme; Leonhardt, Steffen

    2016-01-01

    Recent work in unobtrusive sleep/wake classification has shown that cardiac and respiratory features can help improve classification performance. Nevertheless, actigraphy remains the single most discriminative modality for this task. Unfortunately, it requires the use of dedicated devices in addition to the sensors used to measure electrocardiogram (ECG) or respiratory effort. This paper proposes a method to estimate actigraphy from the body movement artifacts present in the ECG and respiratory inductance plethysmography (RIP) based on the time-frequency analysis of those signals. Using a continuous wavelet transform to analyze RIP, and ECG and RIP combined, it provides a surrogate measure of actigraphy with moderate correlation (for ECG+RIP, ρ = 0.74, p  <  0.001) and agreement (mean bias ratio of 0.94 and 95% agreement ratios of 0.11 and 8.45) with reference actigraphy. More important, it can be used as a replacement of actigraphy in sleep/wake classification: after cross-validation with a data set comprising polysomnographic (PSG) recordings of 15 healthy subjects and 25 insomniacs annotated by an external sleep technician, it achieves a statistically non-inferior classification performance when used together with respiratory features (average κ of 0.64 for 15 healthy subjects, and 0.50 for a dataset with 40 healthy and insomniac subjects), and when used together with respiratory and cardiac features (average κ of 0.66 for 15 healthy subjects, and 0.56 for 40 healthy and insomniac subjects). Since this method eliminates the need for a dedicated actigraphy device, it reduces the number of sensors needed for sleep/wake classification to a single sensor when using respiratory features, and to two sensors when using respiratory and cardiac features without any loss in performance. It offers a major benefit in terms of comfort for long-term home monitoring and is immediately applicable for legacy ECG and RIP monitoring devices already used in clinical

  4. Genesis of multipeaked waves of the esophagus: repetitive contractions or motion artifact?

    Science.gov (United States)

    Sampath, Neha J; Bhargava, Valmik; Mittal, Ravinder K

    2010-06-01

    Multipeaked waves (MPW) in the distal esophagus occur frequently in patients with esophageal spastic motor disorders and diabetes mellitus and are thought to represent repetitive esophageal contractions. We aimed to investigate whether the relative motion between a stationary pressure sensor and contracted peristaltic esophageal segment that moves with respiration leads to the formation of MPW. We mathematically modeled the effect of relative movement between a moving pressure segment and a fixed pressure sensor on the pressure waveform morphology. We conducted retrospective analysis of 100 swallow-induced esophageal contractions in 10 patients, who demonstrated >30% MPW on high-resolution manometry (HRM) during standardized swallows. Finally, using HRM, we determined the effects of suspended breathing and hyperventilation on the waveform morphology in 10 patients prospectively. Modeling revealed that relative movement between a stationary pressure sensor and a moving contracted segment, contraction duration, contraction amplitude, respiratory frequency, and depth of respiration affects the waveform morphology. Retrospective analysis demonstrated a close temporal association with the onset of second and subsequent contractions in MPW with respiratory phase reversals. Numbers of peaks in MPW and respiratory phase reversals were closely related to the duration of contraction. In the prospective study, suspended breathing and hyperventilation resulted in a significant decrease and increase in the MPW frequency as well as the number of peaks within MPW respectively. We conclude that MPW observed during clinical motility studies are not indicative of repetitive esophageal contraction; rather they represent respiration-related movement of the contracted esophageal segment in relation to the stationary pressure sensor.

  5. Neural mechanism for sensing fast motion in dim light.

    Science.gov (United States)

    Li, Ran; Wang, Yi

    2013-11-07

    Luminance is a fundamental property of visual scenes. A population of neurons in primary visual cortex (V1) is sensitive to uniform luminance. In natural vision, however, the retinal image often changes rapidly. Consequently the luminance signals visual cells receive are transiently varying. How V1 neurons respond to such luminance changes is unknown. By applying large static uniform stimuli or grating stimuli altering at 25 Hz that resemble the rapid luminance changes in the environment, we show that approximately 40% V1 cells responded to rapid luminance changes of uniform stimuli. Most of them strongly preferred luminance decrements. Importantly, when tested with drifting gratings, the preferred speeds of these cells were significantly higher than cells responsive to static grating stimuli but not to uniform stimuli. This responsiveness can be accounted for by the preferences for low spatial frequencies and high temporal frequencies. These luminance-sensitive cells subserve the detection of fast motion under the conditions of dim illumination.

  6. Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging.

    Science.gov (United States)

    Miwa, Kenta; Umeda, Takuro; Murata, Taisuke; Wagatsuma, Kei; Miyaji, Noriaki; Terauchi, Takashi; Koizumi, Mitsuru; Sasaki, Masayuki

    2016-02-01

    Overcorrection of scatter caused by patient motion during whole-body PET/computed tomography (CT) imaging can induce the appearance of photopenic artifacts in the PET images. The present study aimed to quantify the accuracy of scatter limitation correction (SLC) for eliminating photopenic artifacts. This study analyzed photopenic artifacts in (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT images acquired from 12 patients and from a National Electrical Manufacturers Association phantom with two peripheral plastic bottles that simulated the human body and arms, respectively. The phantom comprised a sphere (diameter, 10 or 37 mm) containing fluorine-18 solutions with target-to-background ratios of 2, 4, and 8. The plastic bottles were moved 10 cm posteriorly between CT and PET acquisitions. All PET data were reconstructed using model-based scatter correction (SC), no scatter correction (NSC), and SLC, and the presence or absence of artifacts on the PET images was visually evaluated. The SC and SLC images were also semiquantitatively evaluated using standardized uptake values (SUVs). Photopenic artifacts were not recognizable in any NSC and SLC image from all 12 patients in the clinical study. The SUVmax of mismatched SLC PET/CT images were almost equal to those of matched SC and SLC PET/CT images. Applying NSC and SLC substantially eliminated the photopenic artifacts on SC PET images in the phantom study. SLC improved the activity concentration of the sphere for all target-to-background ratios. The highest %errors of the 10 and 37-mm spheres were 93.3 and 58.3%, respectively, for mismatched SC, and 73.2 and 22.0%, respectively, for mismatched SLC. Photopenic artifacts caused by SC error induced by CT and PET image misalignment were corrected using SLC, indicating that this method is useful and practical for clinical qualitative and quantitative PET/CT assessment.

  7. Free-breathing high-pitch 80kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose.

    Science.gov (United States)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J; Scholtz, Jan-Erik

    2017-04-01

    To investigate image quality, presence of motion artifacts and effects on radiation dose of 80kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1±4.9years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n=31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n=56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p>0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (pchest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Bodelle, Boris, E-mail: bbodelle@googlemail.com; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik

    2017-04-15

    Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 ± 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation.

  9. Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

    International Nuclear Information System (INIS)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik

    2017-01-01

    Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 ± 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation.

  10. A technique to reduce motion artifact for externally triggered cine-MRI(EC-MRI) based on detecting the onset of the articulated word with spectral analysis

    International Nuclear Information System (INIS)

    Shimada, Yasuhiro; Nishimoto, Hironori; Kochiyama, Takanori; Fujimoto, Ichiro; Mano, Hiroaki; Masaki, Shinobu; Murase, Kenya

    2012-01-01

    One issue in externally triggered cine-magnetic resonance imaging (EC-MRI) for the dynamic observation of speech organs is motion artifact in the phase-encoding direction caused by unstable repetitions of speech during data acquisition. We propose a technique to reduce such artifact by rearranging the k-space data used to reconstruct MR images based on the analysis of recorded speech sounds. We recorded the subject's speech sounds during EC-MRI and used post hoc acoustical processing to reduce scanning noise and detect the onset of each utterance based on analysis of the recorded sounds. We selected each line of k-space from several data acquisition sessions and rearranged them to reconstruct a new series of dynamic MR images according to the analyzed time of utterance onset. Comparative evaluation showed significant reduction in motion artifact signal in the dynamic MR images reconstructed by the proposed method. The quality of the reconstructed images was sufficient to observe the dynamic aspects of speech production mechanisms. (author)

  11. Effect of motion artifacts and their correction on near-infrared spectroscopy oscillation data: a study in healthy subjects and stroke patients.

    Science.gov (United States)

    Selb, Juliette; Yücel, Meryem A; Phillip, Dorte; Schytz, Henrik W; Iversen, Helle K; Vangel, Mark; Ashina, Messoud; Boas, David A

    2015-05-01

    Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functional connectivity and autoregulation studies. We use as our metric of interest the interhemispheric correlation (IHC), the correlation coefficient between symmetrical time series of oxyhemoglobin oscillations. We show that increased motion content results in a decreased IHC. Using a set of motion-free data on which we add real MAs, we find that the best motion correction approach consists of discarding the segments of MAs following a careful approach to minimize the contamination due to band-pass filtering of data from "bad" segments spreading into adjacent "good" segments. Finally, we compare the IHC in a stroke group and in a healthy group that we artificially contaminated with the MA content of the stroke group, in order to avoid the confounding effect of increased motion incidence in the stroke patients. After motion correction, the IHC remains lower in the stroke group in the frequency band around 0.1 and 0.04 Hz, suggesting a physiological origin for the difference. We emphasize the importance of considering MAs as a confounding factor in oscillation-based functional near-infrared spectroscopy studies.

  12. Hardware architecture design of a fast global motion estimation method

    Science.gov (United States)

    Liang, Chaobing; Sang, Hongshi; Shen, Xubang

    2015-12-01

    VLSI implementation of gradient-based global motion estimation (GME) faces two main challenges: irregular data access and high off-chip memory bandwidth requirement. We previously proposed a fast GME method that reduces computational complexity by choosing certain number of small patches containing corners and using them in a gradient-based framework. A hardware architecture is designed to implement this method and further reduce off-chip memory bandwidth requirement. On-chip memories are used to store coordinates of the corners and template patches, while the Gaussian pyramids of both the template and reference frame are stored in off-chip SDRAMs. By performing geometric transform only on the coordinates of the center pixel of a 3-by-3 patch in the template image, a 5-by-5 area containing the warped 3-by-3 patch in the reference image is extracted from the SDRAMs by burst read. Patched-based and burst mode data access helps to keep the off-chip memory bandwidth requirement at the minimum. Although patch size varies at different pyramid level, all patches are processed in term of 3x3 patches, so the utilization of the patch-processing circuit reaches 100%. FPGA implementation results show that the design utilizes 24,080 bits on-chip memory and for a sequence with resolution of 352x288 and frequency of 60Hz, the off-chip bandwidth requirement is only 3.96Mbyte/s, compared with 243.84Mbyte/s of the original gradient-based GME method. This design can be used in applications like video codec, video stabilization, and super-resolution, where real-time GME is a necessity and minimum memory bandwidth requirement is appreciated.

  13. E-Bra system for women ECG measurement with GPRS communication, Nanosensor, and motion artifact remove algorithm

    Science.gov (United States)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth S.; Varadan, Vijay K.

    2012-10-01

    with conductive gel. However, the gel can be dried when taking long time monitoring. The gold nanowire structure electrodes without consideration of uncomfortable usage of gel are attached on beneath the chest position of a brassiere, and the electrodes convert the physical ECG signal to voltage potential signal. The voltage potential ECG signal is converted to digital signal by AD converter included in microprocessor. The converted ECG signal by AD converter is saved on every 1 sec period in the internal RAM in microprocessor. For transmission of the saved data in the internal RAM to a server computer locating at remote area, the system uses the GPRS communication technology, which can develop the wide area network(WAP) without any gateway and repeater. In addition, the transmission system is operated on client mode of GPRS communication. The remote server is installed a program including the functions of displaying and analyzing the transmitted ECG. To display the ECG data, the program is operated with TCP/IP server mode and static IP address, and to analyze the ECG data, the paper suggests motion artifact remove algorithm including adaptive filter with LMS(least mean square), baseline detection algorithm using predictability estimation theory, a filter with moving weighted factor, low pass filter, peak to peak detection, and interpolation.

  14. ROBUST MOTION SEGMENTATION FOR HIGH DEFINITION VIDEO SEQUENCES USING A FAST MULTI-RESOLUTION MOTION ESTIMATION BASED ON SPATIO-TEMPORAL TUBES

    OpenAIRE

    Brouard , Olivier; Delannay , Fabrice; Ricordel , Vincent; Barba , Dominique

    2007-01-01

    4 pages; International audience; Motion segmentation methods are effective for tracking video objects. However, objects segmentation methods based on motion need to know the global motion of the video in order to back-compensate it before computing the segmentation. In this paper, we propose a method which estimates the global motion of a High Definition (HD) video shot and then segments it using the remaining motion information. First, we develop a fast method for multi-resolution motion est...

  15. Optimization of three-dimensional triple IR fast spoiled gradient recalled acquisition in the steady state (FSPGR) to decrease vascular artifact at 3.0 Tesla

    International Nuclear Information System (INIS)

    Fujiwara, Yasuhiro; Fukuya, Yuko; Yamaguchi, Isao; Matsuda, Tsuyoshi; Ishimori, Yoshiyuki; Yamada, Kazuhiro; Kimura, Hirohiko; Miyati, Tosiaki

    2006-01-01

    The purpose of this study was to decrease vascular artifacts caused by the in-flow effect in three-dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady state (3D IR FSPGR) at 3.0 Tesla. We developed 3D triple IR (3IR) FSPGR and examined the signal characteristics of the new sequence. We have optimized scan parameters based on simulation, phantom, and in-vivo studies. As a result, optimized parameters (1st TI=600 ms, 3rd TI=500 ms) successfully have produced the vessel signal at more than 40% reduction, while gray-white matter contrast was preserved. Moreover, the reduced artifact was also confirmed by visual inspection of the in-vivo images for which this condition was used. Thus, 3D 3IR FSPGR was a useful sequence for the acquisition of T1-weighted images at 3.0 Tesla. (author)

  16. Molten fuel motion during a fast-reactor overpower transient

    International Nuclear Information System (INIS)

    Kolesar, D.C.; Padilla, A. Jr.; Lewis, C.H.; Waltar, A.E.

    1976-01-01

    Mechanistic models for postfailure fuel behavior during hypothetical transient overpower accidents are currently being developed for incorporation into the MELT accident analysis code. A new model for the fuel-coolant interaction and for the motion of fuel in the coolant channel has been developed and incorporated into the MELT-III code. A major limitation of the mechanistic fuel motion model is its dependence on the uniform interaction region of MELT-III. Consequently, a parallel effort is currently in progress to incorporate a non-uniform interaction region into the MELT code. Combination of the fuel motion and the nonuniform interaction region models will provide the framework for development of a mechanistic fuel plateout/blockage model for transient overpower accidents

  17. Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit

    International Nuclear Information System (INIS)

    Greuter, Marcel J.W.; Dorgelo, Joost; Tukker, Wim G.J.; Oudkerk, Matthijs

    2005-01-01

    Acquisition time plays a key role in the quality of cardiac multidetector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of coronary arteries of an anthropomorphic adjustable moving heart phantom on an ECG-gated MDCT unit. The heart phantom and a coronary artery phantom were used on a MDCT unit with a rotation time of 500 ms. The movement of the heart was determined by analysis of the images taken at different phases. The results indicate that the movement of the coronary arteries on the heart phantom is comparable to that in a clinical setting. The influence of the heart rate on image quality and artifacts was determined by analysis of several heart rates between 40 and 80 bpm where the movement of the heart was synchronized using a retrospective ECG-gated acquisition protocol. The resulting reformatted volume rendering images of the moving heart and the coronary arteries were qualitatively compared as a result of the heart rate. The evaluation was performed on three independent series by two independent radiologists for the image quality of the coronary arteries and the presence of artifacts. The evaluation shows that at heart rates above 50 bpm the influence of motion artifacts in the coronary arteries becomes apparent. In addition the influence of a dedicated multisector reconstruction technique on image quality was determined. The results show that the image quality of the coronary arteries is not only related to the heart rate and that the influence of the multisector reconstruction technique becomes significant above 70 bpm. Therefore, this study proves that from the actual acquisition time per heart cycle one cannot determine an actual acquisition time, but only a mathematical acquisition time. (orig.)

  18. Revealing the fast atomic motion of network glasses.

    Science.gov (United States)

    Ruta, B; Baldi, G; Chushkin, Y; Rufflé, B; Cristofolini, L; Fontana, A; Zanatta, M; Nazzani, F

    2014-05-19

    Still very little is known on the relaxation dynamics of glasses at the microscopic level due to the lack of experiments and theories. It is commonly believed that glasses are in a dynamical arrested state, with relaxation times too large to be observed on human time scales. Here we provide the experimental evidence that glasses display fast atomic rearrangements within a few minutes, even in the deep glassy state. Following the evolution of the structural relaxation in a sodium silicate glass, we find that this fast dynamics is accompanied by the absence of any detectable aging, suggesting a decoupling of the relaxation time and the viscosity in the glass. The relaxation time is strongly affected by the network structure with a marked increase at the mesoscopic scale associated with the ion-conducting pathways. Our results modify the conception of the glassy state and asks for a new microscopic theory.

  19. Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

    Directory of Open Access Journals (Sweden)

    Minho Choi

    2016-05-01

    Full Text Available Non-intrusive electrocardiogram (ECG monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.

  20. Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact. Evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Nishiura, Motoko; Johkoh, Takeshi; Yamamoto, Shuji

    2007-01-01

    The aim of this study was to evaluate the decreasing of cardiac motion artifact and whether the extent of ground-glass attenuation of idiopathic pulmonary fibrosis (IPF) was accurately assessed by electrocardiography (ECG)-triggered high-resolution computed tomography (HRCT) by 0.5-s/rotation multidetector-row CT (MDCT). ECG-triggered HRCT were scanned at the end-diastolic phase by a MDCT scanner with the following scan parameters; axial four-slice mode, 0.5 mm collimation, 0.5-s/rotation, 120 kVp, 200 mA/rotation, high-frequency algorithm, and half reconstruction. In 42 patients with IPF, both conventional HRCT (ECG gating (-), full reconstruction) and ECG-triggered HRCT were performed at the same levels (10-mm intervals) with the above scan parameters. The correlation between percent diffusion of carbon monoxide of the lung (%DLCO) and the mean extent of ground-glass attenuation on both conventional HRCT and ECG-triggered HRCT was evaluated with the Spearman rank correlation coefficient test. The correlation between %DLCO and the mean extent of ground-glass attenuation on ECG-triggered HRCT (observer A: r=-0.790, P<0.0001; observer B: r=-0.710, P<0.0001) was superior to that on conventional HRCT (observer A: r=-0.395, P<0.05; observer B: r=-0.577, P=0.002) for both observers. ECG-triggered HRCT by 0.5 s/rotation MDCT can reduce the cardiac motion artifact and is useful for evaluating the extent of ground-glass attenuation of IPF. (author)

  1. Fast Numerical Simulation of Focused Ultrasound Treatments During Respiratory Motion With Discontinuous Motion Boundaries.

    Science.gov (United States)

    Schwenke, Michael; Georgii, Joachim; Preusser, Tobias

    2017-07-01

    Focused ultrasound (FUS) is rapidly gaining clinical acceptance for several target tissues in the human body. Yet, treating liver targets is not clinically applied due to a high complexity of the procedure (noninvasiveness, target motion, complex anatomy, blood cooling effects, shielding by ribs, and limited image-based monitoring). To reduce the complexity, numerical FUS simulations can be utilized for both treatment planning and execution. These use-cases demand highly accurate and computationally efficient simulations. We propose a numerical method for the simulation of abdominal FUS treatments during respiratory motion of the organs and target. Especially, a novel approach is proposed to simulate the heating during motion by solving Pennes' bioheat equation in a computational reference space, i.e., the equation is mathematically transformed to the reference. The approach allows for motion discontinuities, e.g., the sliding of the liver along the abdominal wall. Implementing the solver completely on the graphics processing unit and combining it with an atlas-based ultrasound simulation approach yields a simulation performance faster than real time (less than 50-s computing time for 100 s of treatment time) on a modern off-the-shelf laptop. The simulation method is incorporated into a treatment planning demonstration application that allows to simulate real patient cases including respiratory motion. The high performance of the presented simulation method opens the door to clinical applications. The methods bear the potential to enable the application of FUS for moving organs.

  2. Heart Motion Prediction in Robotic-Assisted Beating Heart Surgery: A Nonlinear Fast Adaptive Approach

    Directory of Open Access Journals (Sweden)

    Fan Liang

    2013-01-01

    Full Text Available Off-pump Coronary Artery Bypass Graft (CABG surgery outperforms traditional on-pump surgery because the assisted robotic tools can alleviate the relative motion between the beating heart and robotic tools. Therefore, it is possible for the surgeon to operate on the beating heart and thus lessens post surgery complications for the patients. Due to the highly irregular and non-stationary nature of heart motion, it is critical that the beating heart motion is predicted in the model-based track control procedures. It is technically preferable to model heart motion in a nonlinear way because the characteristic analysis of 3D heart motion data through Bi-spectral analysis and Fourier methods demonstrates the involved nonlinearity of heart motion. We propose an adaptive nonlinear heart motion model based on the Volterra Series in this paper. We also design a fast lattice structure to achieve computational-efficiency for real-time online predictions. We argue that the quadratic term of the Volterra Series can improve the prediction accuracy by covering sharp change points and including the motion with sufficient detail. The experiment results indicate that the adaptive nonlinear heart motion prediction algorithm outperforms the autoregressive (AR and the time-varying Fourier-series models in terms of the root mean square of the prediction error and the prediction error in extreme cases.

  3. Breaking cover: neural responses to slow and fast camouflage-breaking motion.

    Science.gov (United States)

    Yin, Jiapeng; Gong, Hongliang; An, Xu; Chen, Zheyuan; Lu, Yiliang; Andolina, Ian M; McLoughlin, Niall; Wang, Wei

    2015-08-22

    Primates need to detect and recognize camouflaged animals in natural environments. Camouflage-breaking movements are often the only visual cue available to accomplish this. Specifically, sudden movements are often detected before full recognition of the camouflaged animal is made, suggesting that initial processing of motion precedes the recognition of motion-defined contours or shapes. What are the neuronal mechanisms underlying this initial processing of camouflaged motion in the primate visual brain? We investigated this question using intrinsic-signal optical imaging of macaque V1, V2 and V4, along with computer simulations of the neural population responses. We found that camouflaged motion at low speed was processed as a direction signal by both direction- and orientation-selective neurons, whereas at high-speed camouflaged motion was encoded as a motion-streak signal primarily by orientation-selective neurons. No population responses were found to be invariant to the camouflage contours. These results suggest that the initial processing of camouflaged motion at low and high speeds is encoded as direction and motion-streak signals in primate early visual cortices. These processes are consistent with a spatio-temporal filter mechanism that provides for fast processing of motion signals, prior to full recognition of camouflage-breaking animals. © 2015 The Authors.

  4. Triangular Geometrized Sampling Heuristics for Fast Optimal Motion Planning

    Directory of Open Access Journals (Sweden)

    Ahmed Hussain Qureshi

    2015-02-01

    Full Text Available Rapidly-exploring Random Tree (RRT-based algorithms have become increasingly popular due to their lower computational complexity as compared with other path planning algorithms. The recently presented RRT* motion planning algorithm improves upon the original RRT algorithm by providing optimal path solutions. While RRT determines an initial collision-free path fairly quickly, RRT* guarantees almost certain convergence to an optimal, obstacle-free path from the start to the goal points for any given geometrical environment. However, the main limitations of RRT* include its slow processing rate and high memory consumption, due to the large number of iterations required for calculating the optimal path. In order to overcome these limitations, we present another improvement, i.e, the Triangular Geometerized-RRT* (TG-RRT* algorithm, which utilizes triangular geometrical methods to improve the performance of the RRT* algorithm in terms of the processing time and a decreased number of iterations required for an optimal path solution. Simulations comparing the performance results of the improved TG-RRT* with RRT* are presented to demonstrate the overall improvement in performance and optimal path detection.

  5. Lévy meets poisson: a statistical artifact may lead to erroneous recategorization of Lévy walk as Brownian motion.

    Science.gov (United States)

    Gautestad, Arild O

    2013-03-01

    The flow of GPS data on animal space is challenging old paradigms, such as the issue of the scale-free Lévy walk versus scale-specific Brownian motion. Since these movement classes often require different protocols with respect to ecological analyses, further theoretical development in this field is important. I describe central concepts such as scale-specific versus scale-free movement and the difference between mechanistic and statistical-mechanical levels of analysis. Next, I report how a specific sampling scheme may have produced much confusion: a Lévy walk may be wrongly categorized as Brownian motion if the duration of a move, or bout, is used as a proxy for step length and a move is subjectively defined. Hence, the categorization and recategorization of movement class compliance surrounding the Lévy walk controversy may have been based on a statistical artifact. This issue may be avoided by collecting relocations at a fixed rate at a temporal scale that minimizes over- and undersampling.

  6. Calibration and quantification of fast intracellular motion (FIM) in living cells using correlation analysis

    Czech Academy of Sciences Publication Activity Database

    Veselý, Pavel; Mikš, A.; Novák, J.; Boyde, A.

    2003-01-01

    Roč. 25, - (2003), s. 230-239 ISSN 0161-0457 R&D Projects: GA ČR GA304/99/0368 Institutional research plan: CEZ:AV0Z5052915 Keywords : fast intracellular motion * living cell ů video rate confocal laser scanning microscopy Subject RIV: EA - Cell Biology Impact factor: 0.733, year: 2003

  7. SAD PROCESSOR FOR MULTIPLE MACROBLOCK MATCHING IN FAST SEARCH VIDEO MOTION ESTIMATION

    Directory of Open Access Journals (Sweden)

    Nehal N. Shah

    2015-02-01

    Full Text Available Motion estimation is a very important but computationally complex task in video coding. Process of determining motion vectors based on the temporal correlation of consecutive frame is used for video compression. In order to reduce the computational complexity of motion estimation and maintain the quality of encoding during motion compensation, different fast search techniques are available. These block based motion estimation algorithms use the sum of absolute difference (SAD between corresponding macroblock in current frame and all the candidate macroblocks in the reference frame to identify best match. Existing implementations can perform SAD between two blocks using sequential or pipeline approach but performing multi operand SAD in single clock cycle with optimized recourses is state of art. In this paper various parallel architectures for computation of the fixed block size SAD is evaluated and fast parallel SAD architecture is proposed with optimized resources. Further SAD processor is described with 9 processing elements which can be configured for any existing fast search block matching algorithm. Proposed SAD processor consumes 7% fewer adders compared to existing implementation for one processing elements. Using nine PE it can process 84 HD frames per second in worse case which is good outcome for real time implementation. In average case architecture process 325 HD frames per second.

  8. iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

    Directory of Open Access Journals (Sweden)

    Kenta Matsumura

    Full Text Available Recent progress in information and communication technologies has made it possible to measure heart rate (HR and normalized pulse volume (NPV, which are important physiological indices, using only a smartphone. This has been achieved with reflection mode photoplethysmography (PPG, by using a smartphone's embedded flash as a light source and the camera as a light sensor. Despite its widespread use, the method of PPG is susceptible to motion artifacts as physical displacements influence photon propagation phenomena and, thereby, the effective optical path length. Further, it is known that the wavelength of light used for PPG influences the photon penetration depth and we therefore hypothesized that influences of motion artifact could be wavelength-dependant. To test this hypothesis, we made measurements in 12 healthy volunteers of HR and NPV derived from reflection mode plethysmograms recorded simultaneously at three different spectral regions (red, green and blue at the same physical location with a smartphone. We then assessed the accuracy of the HR and NPV measurements under the influence of motion artifacts. The analyses revealed that the accuracy of HR was acceptably high with all three wavelengths (all rs > 0.996, fixed biases: -0.12 to 0.10 beats per minute, proportional biases: r =  -0.29 to 0.03, but that of NPV was the best with green light (r = 0.791, fixed biases: -0.01 arbitrary units, proportional bias: r = 0.11. Moreover, the signal-to-noise ratio obtained with green and blue light PPG was higher than that of red light PPG. These findings suggest that green is the most suitable color for measuring HR and NPV from the reflection mode photoplethysmogram under motion artifact conditions. We conclude that the use of green light PPG could be of particular benefit in ambulatory monitoring where motion artifacts are a significant issue.

  9. Reduction of CSF flow artifact in fast fluid attenuated inversion recovery MR imaging. Study of excitation width in 180deg inversion pulse

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Yoshizawa, Satoshi; Maki, Toshio; Kitagawa, Matsuo; Suzuki, Ken; Fujita, Isao

    1998-01-01

    A technique that increases slice thickness so that it becomes wider than the excitation width of the 180deg inversion pulse and in which TR is partitioned twice has been investigated with regard to fast FLAIR. This is a technique that reduces the flow artifact of CSF. It is thought that, with this technique, the flow artifact is reduced because the CSF that flows onto the slice reaches the null point. The cross talk effect of the 180deg inversion pulse appears as a high CSF signal. As a result, the number of slices needs to be partitioned two or three times before imaging. Thus the imaging time is doubled or tripled. Considering the cross talk effect of the 180deg inversion pulse and the imaging time needed for this technique, the optimal imaging technique would be one that uses an inversion pulse that is four times slice thickness plus slice space and for which the number of slices is partitioned twice. Furthermore, the null point of CSF was dependent on dividing TR in half. (author)

  10. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking

    DEFF Research Database (Denmark)

    Ravkilde, Thomas; Keall, Paul J.; Grau, Cai

    2014-01-01

    of the algorithm for reconstruction of dose and motion-induced dose errors throughout the tracking and non-tracking beam deliveries was quantified. Doses were reconstructed with a mean dose difference relative to the measurements of -0.5% (5.5% standard deviation) for cumulative dose. More importantly, the root...... validate a simple model for fast motion-including dose error reconstruction applicable to intrafractional QA of MLC tracking treatments of moving targets. MLC tracking experiments were performed on a standard linear accelerator with prototype MLC tracking software guided by an electromagnetic transponder......-mean-square deviation between reconstructed and measured motion-induced 3%/3 mm γ failure rates (dose error) was 2.6%. The mean computation time for each calculation of dose and dose error was 295 ms. The motion-including dose reconstruction allows accurate temporal and spatial pinpointing of errors in absorbed dose...

  11. Artifacts produced during electrical stimulation of the vestibular nerve in cats. [autonomic nervous system components of motion sickness

    Science.gov (United States)

    Tang, P. C.

    1973-01-01

    Evidence is presented to indicate that evoked potentials in the recurrent laryngeal, the cervical sympathetic, and the phrenic nerve, commonly reported as being elicited by vestibular nerve stimulation, may be due to stimulation of structures other than the vestibular nerve. Experiments carried out in decerebrated cats indicated that stimulation of the petrous bone and not that of the vestibular nerve is responsible for the genesis of evoked potentials in the recurrent laryngeal and the cervical sympathetic nerves. The phrenic response to electrical stimulation applied through bipolar straight electrodes appears to be the result of stimulation of the facial nerve in the facial canal by current spread along the petrous bone, since stimulation of the suspended facial nerve evoked potentials only in the phrenic nerve and not in the recurrent laryngeal nerve. These findings indicate that autonomic components of motion sickness represent the secondary reactions and not the primary responses to vestibular stimulation.

  12. Effects of cholesterol or gramicidin on slow and fast motions of phospholipids in oriented bilayers

    International Nuclear Information System (INIS)

    Peng, Z.Y.; Simplaceanu, V.; Dowd, S.R.; Ho, C.

    1989-01-01

    Nuclear spin-lattice relaxation both in the rotating frame and in the laboratory frame is used to investigate the slow and fast molecular motions of phospholipids in oriented bilayers in the liquid crystalline phase. The bilayers are prepared from a perdeuterated phospholipid labeled with a pair of 19 F atoms at the 7 position of the 2-sn acyl chain. Phospholipid-cholesterol or phospholipid-gramicidin interactions are characterized by measuring the relaxation rates as a function of the bilayer orientation, the locking field, and the temperature. These studies show that cholesterol or gramicidin can specifically enhance the relaxation due to slow motions in phospholipid bilayers with correlation times τ s longer than 10 -8 sec. The perturbations of the geometry of the slow motions induced by cholesterol are qualitatively different from those induced by gramicidin. In contrast, the presence of cholesterol or gramicidin slightly suppresses the fast motions with correlation times τ f = 10 -9 to 10 -10 sec without significantly affecting their geometry. Weak locking-field and temperature dependences are observed for both pure lipid bilayers and bilayers containing either cholesterol or gramicidin, suggesting that the motions of phospholipid acyl chains may have dispersed correlation times

  13. Fast compressed domain motion detection in H.264 video streams for video surveillance applications

    DEFF Research Database (Denmark)

    Szczerba, Krzysztof; Forchhammer, Søren; Støttrup-Andersen, Jesper

    2009-01-01

    This paper presents a novel approach to fast motion detection in H.264/MPEG-4 advanced video coding (AVC) compressed video streams for IP video surveillance systems. The goal is to develop algorithms which may be useful in a real-life industrial perspective by facilitating the processing of large...... on motion vectors embedded in the video stream without requiring a full decoding and reconstruction of video frames. To improve the robustness to noise, a confidence measure based on temporal and spatial clues is introduced to increase the probability of correct detection. The algorithm was tested on indoor...

  14. Variable disparity-motion estimation based fast three-view video coding

    Science.gov (United States)

    Bae, Kyung-Hoon; Kim, Seung-Cheol; Hwang, Yong Seok; Kim, Eun-Soo

    2009-02-01

    In this paper, variable disparity-motion estimation (VDME) based 3-view video coding is proposed. In the encoding, key-frame coding (KFC) based motion estimation and variable disparity estimation (VDE) for effectively fast three-view video encoding are processed. These proposed algorithms enhance the performance of 3-D video encoding/decoding system in terms of accuracy of disparity estimation and computational overhead. From some experiments, stereo sequences of 'Pot Plant' and 'IVO', it is shown that the proposed algorithm's PSNRs is 37.66 and 40.55 dB, and the processing time is 0.139 and 0.124 sec/frame, respectively.

  15. Effect of pressure on the fast motions in ordered phase phospholipid bilayers

    Energy Technology Data Exchange (ETDEWEB)

    Singh, H

    2005-07-01

    Application of hydrostatic pressure to phospholipid bilayers increases acyl chain order and raises the main transition temperature. {sup 2}H NMR spectra and quadrupole echo decay times were obtained at ambient pressure and pressures of 85 MPa and 196.1 MPa for ordered phase bilayers of a zwitterionic phospholipid : 16:0-16:0 PC-d{sub 62} (DPPC-d{sub 62}) and an anionic phospholipid : 16:0-16:0 PG-d{sub 62} (DPPG-d{sub 62}). The extent to which deuterium magnetization following an RF pulse is refocused in the echo after a second pulse is limited by the motions that modulate the orientation-dependent quadrupole interaction. The q-CPMG pulse sequence is used to separate the contribution of slow and fast motions to the echo decay rate. This work provides insight into how chain packing affects local motion.

  16. Precise Aperture-Dependent Motion Compensation with Frequency Domain Fast Back-Projection Algorithm

    Directory of Open Access Journals (Sweden)

    Man Zhang

    2017-10-01

    Full Text Available Precise azimuth-variant motion compensation (MOCO is an essential and difficult task for high-resolution synthetic aperture radar (SAR imagery. In conventional post-filtering approaches, residual azimuth-variant motion errors are generally compensated through a set of spatial post-filters, where the coarse-focused image is segmented into overlapped blocks concerning the azimuth-dependent residual errors. However, image domain post-filtering approaches, such as precise topography- and aperture-dependent motion compensation algorithm (PTA, have difficulty of robustness in declining, when strong motion errors are involved in the coarse-focused image. In this case, in order to capture the complete motion blurring function within each image block, both the block size and the overlapped part need necessary extension leading to degeneration of efficiency and robustness inevitably. Herein, a frequency domain fast back-projection algorithm (FDFBPA is introduced to deal with strong azimuth-variant motion errors. FDFBPA disposes of the azimuth-variant motion errors based on a precise azimuth spectrum expression in the azimuth wavenumber domain. First, a wavenumber domain sub-aperture processing strategy is introduced to accelerate computation. After that, the azimuth wavenumber spectrum is partitioned into a set of wavenumber blocks, and each block is formed into a sub-aperture coarse resolution image via the back-projection integral. Then, the sub-aperture images are straightforwardly fused together in azimuth wavenumber domain to obtain a full resolution image. Moreover, chirp-Z transform (CZT is also introduced to implement the sub-aperture back-projection integral, increasing the efficiency of the algorithm. By disusing the image domain post-filtering strategy, robustness of the proposed algorithm is improved. Both simulation and real-measured data experiments demonstrate the effectiveness and superiority of the proposal.

  17. Artifacts in Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Krupa, Katarzyna; Bekiesińska-Figatowska, Monika

    2015-01-01

    Artifacts in magnetic resonance imaging and foreign bodies within the patient’s body may be confused with a pathology or may reduce the quality of examinations. Radiologists are frequently not informed about the medical history of patients and face postoperative/other images they are not familiar with. A gallery of such images was presented in this manuscript. A truncation artifact in the spinal cord could be misinterpreted as a syrinx. Motion artifacts caused by breathing, cardiac movement, CSF pulsation/blood flow create a ghost artifact which can be reduced by patient immobilization, or cardiac/respiratory gating. Aliasing artifacts can be eliminated by increasing the field of view. An artificially hyperintense signal on FLAIR images can result from magnetic susceptibility artifacts, CSF/vascular pulsation, motion, but can also be found in patients undergoing MRI examinations while receiving supplemental oxygen. Metallic and other foreign bodies which may be found on and in patients’ bodies are the main group of artifacts and these are the focus of this study: e.g. make-up, tattoos, hairbands, clothes, endovascular embolization, prostheses, surgical clips, intraorbital and other medical implants, etc. Knowledge of different types of artifacts and their origin, and of possible foreign bodies is necessary to eliminate them or to reduce their negative influence on MR images by adjusting acquisition parameters. It is also necessary to take them into consideration when interpreting the images. Some proposals of reducing artifacts have been mentioned. Describing in detail the procedures to avoid or limit the artifacts would go beyond the scope of this paper but technical ways to reduce them can be found in the cited literature

  18. Quantifying skin motion artifact error of the hindfoot and forefoot marker clusters with the optical tracking of a multi-segment foot model using single-plane fluoroscopy.

    Science.gov (United States)

    Shultz, R; Kedgley, A E; Jenkyn, T R

    2011-05-01

    The trajectories of skin-mounted markers tracked with optical motion capture are assumed to be an adequate representation of the underlying bone motions. However, it is well known that soft tissue artifact (STA) exists between marker and bone. This study quantifies the STA associated with the hindfoot and midfoot marker clusters of a multi-segment foot model. To quantify STA of the hindfoot and midfoot marker clusters with respect to the calcaneus and navicular respectively, fluoroscopic images were collected on 27 subjects during four quasi-static positions, (1) quiet standing (non-weight bearing), (2) at heel strike (weight-bearing), (3) at midstance (weight-bearing) and (4) at toe-off (weight-bearing). The translation and rotation components of STA were calculated in the sagittal plane. Translational STA at the calcaneus varied from 5.9±7.3mm at heel-strike to 12.1±0.3mm at toe-off. For the navicular the translational STA ranged from 7.6±7.6mm at heel strike to 16.4±16.7mm at toe-off. Rotational STA was relatively smaller for both bones at all foot positions. For the calcaneus they varied between 0.1±2.2° at heel-strike to 0.2±0.6° at toe-off. For the navicular, the rotational STA ranged from 0.6±0.9° at heel-strike to 0.7±0.7° at toe-off. The largest translational STA found in this study (16mm for the navicular) was smaller than those reported in the literature for the thigh and the lower leg, but was larger than the STA of individual spherical markers affixed to the foot. The largest errors occurred at toe-off position for all subjects for both the hindfoot and midfoot clusters. Future studies are recommended to quantify true three-dimensional STA of the entire foot during gait. Copyright © 2011. Published by Elsevier B.V.

  19. A Fast Algorithm to Simulate Droplet Motions in Oil/Water Two Phase Flow

    KAUST Repository

    Zhang, Tao

    2017-06-09

    To improve the research methods in petroleum industry, we develop a fast algorithm to simulate droplet motions in oil and water two phase flow, using phase field model to describe the phase distribution in the flow process. An efficient partial difference equation solver—Shift-Matrix method is applied here, to speed up the calculation coding in high-level language, i.e. Matlab and R. An analytical solution of order parameter is derived, to define the initial condition of phase distribution. The upwind scheme is applied in our algorithm, to make it energy decay stable, which results in the fast speed of calculation. To make it more clear and understandable, we provide the specific code for forming the coefficient matrix used in Shift-Matrix Method. Our algorithm is compared with other methods in different scales, including Front Tracking and VOSET method in macroscopic and LBM method using RK model in mesoscopic scale. In addition, we compare the result of droplet motion under gravity using our algorithm with the empirical formula common used in industry. The result proves the high efficiency and robustness of our algorithm and it’s then used to simulate the motions of multiple droplets under gravity and cross-direction forces, which is more practical in industry and can be extended to wider application.

  20. Deliberate utilization of interaction torques brakes elbow extension in a fast throwing motion.

    Science.gov (United States)

    Hore, Jon; Debicki, Derek B; Gribble, Paul L; Watts, Sherry

    2011-05-01

    We tested the hypothesis that in fast arm movements the CNS deliberately utilizes interaction torques to decelerate (brake) joint rotations. Twelve subjects performed fast 2-D overarm throws in which large elbow extension velocities occurred. Joint motions were computed from recordings made with search coils; joint torques were calculated using inverse dynamics. After ball release, a large follow-through shoulder extension acceleration occurred that was initiated by shoulder extensor muscle torque. This shoulder acceleration produced a flexor interaction torque at the elbow that initiated elbow deceleration (braking). An instantaneous mechanical interaction of passive torques then occurred between elbow and shoulder, i.e., elbow extension deceleration produced a large shoulder extensor interaction torque that contributed to the shoulder extension acceleration which, simultaneously, produced a large elbow flexor interaction torque that contributed to elbow extension deceleration, and so on. Late elbow flexor muscle torque also contributed to elbow deceleration. The interaction of passive torques between shoulder and elbow was braked by shoulder flexor muscle torque. In this mechanism, shoulder musculature contributed to braking elbow extension in two ways: shoulder extensors initiated the mechanical interaction of passive torques between shoulder and elbow and shoulder flexors dissipated kinetic energy from elbow braking. It is concluded that, in fast 2-D throws, the CNS deliberately utilizes powerful interaction torques between shoulder and elbow to brake motion at the elbow.

  1. The calculation of site-dependent earthquake motions -3. The method of fast fourier transform

    International Nuclear Information System (INIS)

    Simpson, I.C.

    1976-10-01

    The method of Fast Fourier transform (FFT) is applied to the problem of the determination of site-dependent earthquake motions, which takes account of local geological effects. A program, VELAY 1, which uses the FFT method has been written and is described in this report. The assumptions of horizontally stratified, homogeneous, isotropic, linearly viscoelastic layers and a normally incident plane seismic wave are made. Several examples are given, using VELAY 1, of modified surface acceleration-time histories obtained using a selected input acceleration-time history and a representative system of soil layers. There is a discussion concerning the soil properties that need to be measured in order to use VELAY 1 (and similar programs described in previous reports) and hence generate site-dependent ground motions suitable for aseismic design of a nuclear power plant at a given site. (author)

  2. A novel directional asymmetric sampling search algorithm for fast block-matching motion estimation

    Science.gov (United States)

    Li, Yue-e.; Wang, Qiang

    2011-11-01

    This paper proposes a novel directional asymmetric sampling search (DASS) algorithm for video compression. Making full use of the error information (block distortions) of the search patterns, eight different direction search patterns are designed for various situations. The strategy of local sampling search is employed for the search of big-motion vector. In order to further speed up the search, early termination strategy is adopted in procedure of DASS. Compared to conventional fast algorithms, the proposed method has the most satisfactory PSNR values for all test sequences.

  3. Fuel motion in overpower tests of metallic integral fast reactor fuel

    International Nuclear Information System (INIS)

    Rhodes, E.A.; Bauer, T.H.; Stanford, G.S.; Regis, J.P.; Dickerman, C.E.

    1992-01-01

    In this paper results from hodoscope data analyses are presented for transient overpower (TOP) tests M5, M6, and M7 at the Transient Reactor Test Facility, with emphasis on transient feedback mechanisms, including prefailure expansion at the tops of the fuel pins, subsequent dispersive axial fuel motion, and losses in relative worth of the fuel pins during the tests. Tests M5 and M6 were the first TOP tests of margin to cladding breach and prefailure elongation of D9-clad ternary (U-Pu-Zr) integral fast reactor-type fuel. Test M7 extended these results to high-burnup fuel and also initiated transient testing of HT-9-clad binary (U-Zr) Fast Flux Test Facility driver fuel. Results show significant prefailure negative reactivity feedback and strongly negative feedback from fuel driven to failure

  4. Probing Motion of Fast Radio Burst Sources by Timing Strongly Lensed Repeaters

    Science.gov (United States)

    Dai, Liang; Lu, Wenbin

    2017-09-01

    Given the possible repetitive nature of fast radio bursts (FRBs), their cosmological origin, and their high occurrence, detection of strongly lensed sources due to intervening galaxy lenses is possible with forthcoming radio surveys. We show that if multiple images of a repeating source are resolved with VLBI, using a method independent of lens modeling, accurate timing could reveal non-uniform motion, either physical or apparent, of the emission spot. This can probe the physical nature of FRBs and their surrounding environments, constraining scenarios including orbital motion around a stellar companion if FRBs require a compact star in a special system, and jet-medium interactions for which the location of the emission spot may randomly vary. The high timing precision possible for FRBs (˜ms) compared with the typical time delays between images in galaxy lensing (≳10 days) enables the measurement of tiny fractional changes in the delays (˜ {10}-9) and hence the detection of time-delay variations induced by relative motions between the source, the lens, and the Earth. We show that uniform cosmic peculiar velocities only cause the delay time to drift linearly, and that the effect from the Earth’s orbital motion can be accurately subtracted, thus enabling a search for non-trivial source motion. For a timing accuracy of ˜1 ms and a repetition rate (of detected bursts) of ˜0.05 per day of a single FRB source, non-uniform displacement ≳0.1-1 au of the emission spot perpendicular to the line of sight is detectable if repetitions are seen over a period of hundreds of days.

  5. Discrimination of common myocardial tomography artifacts

    International Nuclear Information System (INIS)

    Shi Hongcheng; Chen Shaoliang; Yao Zhifeng; Zhu Weimin; Liu Wenguan

    2002-01-01

    To study the characteristics of common myocardial tomography artifacts so as to increase the diagnosis accuracy, 132 patients with myocardial perfusion were reviewed. With careful recognition of artifacts, the patients were re-diagnosed and compared with previous results. It was found that attenuation artifacts and motion artifacts were found frequently in thallium SPECT images. Artifacts caused by thoracic wall were frequent in female and showed a fixed defect in anterior or lateral wall; attenuation artifacts caused by left hemi diaphragm were always found in male and showed that the inferior wall became thinner gradually from apex to bottom in vertical long axis slices. The coexistence of defects and hot areas was the characteristics of motion artifacts. Artifacts caused by non-target organs, liver and/or gastrointestinal tracts, were frequently seen in 99m Tc-MIBI SPECT image. By recognizing the artifacts, misdiagnosis rate decreased significantly from 13.6% to 6.8%. Authors' studies show that all kinds of artifacts have their prevalence rate and imaging feature, the artifacts could be eliminated effectively by careful analysis and some correction measures

  6. Part I. Fuel-motion diagnostics in support of fast-reactor safety experiments. Part II. Fission product detection system in support of fast reactor safety experiments

    International Nuclear Information System (INIS)

    Devolpi, A.; Doerner, R.C.; Fink, C.L.; Regis, J.P.; Rhodes, E.A.; Stanford, G.S.; Braid, T.H.; Boyar, R.E.

    1986-05-01

    In all destructive fast-reactor safety experiments at TREAT, fuel motion and cladding failure have been monitored by the fast-neutron/gamma-ray hodoscope, providing experimental results that are directly applicable to design, modeling, and validation in fast-reactor safety. Hodoscope contributions to the safety program can be considered to fall into several groupings: pre-failure fuel motion, cladding failure, post-failure fuel motion, steel blockages, pretest and posttest radiography, axial-power-profile variations, and power-coupling monitoring. High-quality results in fuel motion have been achieved, and motion sequences have been reconstructed in qualitative and quantitative visual forms. A collimated detection system has been used to observe fission products in the upper regions of a test loop in the TREAT reactor. Particular regions of the loop are targeted through any of five channels in a rotatable assembly in a horizontal hole through the biological shield. A well-type neutron detector, optimized for delayed neutrons, and two GeLi gamma ray spectrometers have been used in several experiments. Data are presented showing a time history of the transport of Dn emitters, of gamma spectra identifying volatile fission products deposited as aerosols, and of fission gas isotopes released from the coolant

  7. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.

    Science.gov (United States)

    Dao, Duy; Salehizadeh, S M A; Noh, Yeonsik; Chong, Jo Woon; Cho, Chae Ho; McManus, Dave; Darling, Chad E; Mendelson, Yitzhak; Chon, Ki H

    2017-09-01

    Motion and noise artifacts (MNAs) impose limits on the usability of the photoplethysmogram (PPG), particularly in the context of ambulatory monitoring. MNAs can distort PPG, causing erroneous estimation of physiological parameters such as heart rate (HR) and arterial oxygen saturation (SpO2). In this study, we present a novel approach, "TifMA," based on using the time-frequency spectrum of PPG to first detect the MNA-corrupted data and next discard the nonusable part of the corrupted data. The term "nonusable" refers to segments of PPG data from which the HR signal cannot be recovered accurately. Two sequential classification procedures were included in the TifMA algorithm. The first classifier distinguishes between MNA-corrupted and MNA-free PPG data. Once a segment of data is deemed MNA-corrupted, the next classifier determines whether the HR can be recovered from the corrupted segment or not. A support vector machine (SVM) classifier was used to build a decision boundary for the first classification task using data segments from a training dataset. Features from time-frequency spectra of PPG were extracted to build the detection model. Five datasets were considered for evaluating TifMA performance: (1) and (2) were laboratory-controlled PPG recordings from forehead and finger pulse oximeter sensors with subjects making random movements, (3) and (4) were actual patient PPG recordings from UMass Memorial Medical Center with random free movements and (5) was a laboratory-controlled PPG recording dataset measured at the forehead while the subjects ran on a treadmill. The first dataset was used to analyze the noise sensitivity of the algorithm. Datasets 2-4 were used to evaluate the MNA detection phase of the algorithm. The results from the first phase of the algorithm (MNA detection) were compared to results from three existing MNA detection algorithms: the Hjorth, kurtosis-Shannon entropy, and time-domain variability-SVM approaches. This last is an approach

  8. Dynamics in artifact ecologies

    DEFF Research Database (Denmark)

    Bødker, Susanne; Klokmose, Clemens Nylandsted

    2012-01-01

    We increasingly interact with multiple interactive artifacts with overlapping capabilities during our daily activities. It has previously been shown that the use of an interactive artifact cannot be understood in isolation, but artifacts must be understood as part of an artifact ecology, where...... artifacts influence the use of others. Understanding this interplay becomes more and more essential for interaction design as our artifact ecologies grow. This paper continues a recent discourse on artifact ecologies. Through interviews with iPhone users, we demonstrate that relationships between artifacts...... in artifact ecologies cannot be understood as static, instead they evolve dynamically over time. We provide activity theory-based concepts to explain these dynamics....

  9. FPSoC-Based Architecture for a Fast Motion Estimation Algorithm in H.264/AVC

    Directory of Open Access Journals (Sweden)

    Obianuju Ndili

    2009-01-01

    Full Text Available There is an increasing need for high quality video on low power, portable devices. Possible target applications range from entertainment and personal communications to security and health care. While H.264/AVC answers the need for high quality video at lower bit rates, it is significantly more complex than previous coding standards and thus results in greater power consumption in practical implementations. In particular, motion estimation (ME, in H.264/AVC consumes the largest power in an H.264/AVC encoder. It is therefore critical to speed-up integer ME in H.264/AVC via fast motion estimation (FME algorithms and hardware acceleration. In this paper, we present our hardware oriented modifications to a hybrid FME algorithm, our architecture based on the modified algorithm, and our implementation and prototype on a PowerPC-based Field Programmable System on Chip (FPSoC. Our results show that the modified hybrid FME algorithm on average, outperforms previous state-of-the-art FME algorithms, while its losses when compared with FSME, in terms of PSNR performance and computation time, are insignificant. We show that although our implementation platform is FPGA-based, our implementation results compare favourably with previous architectures implemented on ASICs. Finally we also show an improvement over some existing architectures implemented on FPGAs.

  10. Cinematic study of temporomandibular joint motion using ultra-fast magnetic resonance imaging.

    Science.gov (United States)

    Manière-Ezvan, A; Havet, T; Franconi, J M; Quémar, J C; de Certaines, J D

    1999-10-01

    Magnetic Resonance Images (MRI) of the temporomandibular joint (TMJ) are usually performed to study the opening/closing movements of the mandible and have up to now been pseudodynamic step-by-step images simulating condylar motion by post-processing reconstruction. The aim of this study was: 1. to optimize a TMJ cine-imaging method to give a better clinical result than the step-by-step methods; 2. to develop an ultra-fast MRI Gradient Echo (GE) sequence for this purpose; and 3. to analyze condylar movements in the sagittal, coronal and para-axial planes during border mandibular displacements and chewing. Both TM joints were studied in six asymptomatic volunteers. The method involved a compromise between in-plane resolution, slice thickness, signal-to-noise ratio and time resolution. Routine clinical use was found to be a GE pulse sequence providing three images per second with an isometric voxel resolution of approximately two millimeters in ridge. This did not allow visualization of the disk. Using this sequence enabled real and simultaneous condylar displacement observation in the three planes of space and therefore contributed to a better functional diagnosis of pathologic TMJ motions.

  11. Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    Science.gov (United States)

    Miranda, Alan; Staelens, Steven; Stroobants, Sigrid; Verhaeghe, Jeroen

    2017-07-01

    To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET point sources (3-4) attached to the rat's head are tracked in image space using 15-32-ms time frames. Our point source tracking (PST) method was validated using a manually moved microDerenzo phantom that was simultaneously tracked with an optical tracker (OT) for comparison. The PST method was further validated in three awake [ 18 F]FDG rat brain scans. Compared with the OT, the PST-based correction at the same frame rate (31.2 Hz) reduced the reconstructed FWHM by 0.39-0.66 mm for the different tested rod sizes of the microDerenzo phantom. The FWHM could be further reduced by another 0.07-0.13 mm when increasing the PST frame rate (66.7 Hz). Regional brain [ 18 F]FDG uptake in the motion corrected scan was strongly correlated ( ) with that of the anesthetized reference scan for all three cases ( ). The proposed PST method allowed excellent and reproducible motion correction in awake in vivo experiments. In addition, there is no need of specialized tracking equipment or additional calibrations to be performed, the point sources are practically imperceptible to the rat, and PST is ideally suitable for small bore scanners, where optical tracking might be challenging.

  12. DMPDS: A Fast Motion Estimation Algorithm Targeting High Resolution Videos and Its FPGA Implementation

    Directory of Open Access Journals (Sweden)

    Gustavo Sanchez

    2012-01-01

    Full Text Available This paper presents a new fast motion estimation (ME algorithm targeting high resolution digital videos and its efficient hardware architecture design. The new Dynamic Multipoint Diamond Search (DMPDS algorithm is a fast algorithm which increases the ME quality when compared with other fast ME algorithms. The DMPDS achieves a better digital video quality reducing the occurrence of local minima falls, especially in high definition videos. The quality results show that the DMPDS is able to reach an average PSNR gain of 1.85 dB when compared with the well-known Diamond Search (DS algorithm. When compared to the optimum results generated by the Full Search (FS algorithm the DMPDS shows a lose of only 1.03 dB in the PSNR. On the other hand, the DMPDS reached a complexity reduction higher than 45 times when compared to FS. The quality gains related to DS caused an expected increase in the DMPDS complexity which uses 6.4-times more calculations than DS. The DMPDS architecture was designed focused on high performance and low cost, targeting to process Quad Full High Definition (QFHD videos in real time (30 frames per second. The architecture was described in VHDL and synthesized to Altera Stratix 4 and Xilinx Virtex 5 FPGAs. The synthesis results show that the architecture is able to achieve processing rates higher than 53 QFHD fps, reaching the real-time requirements. The DMPDS architecture achieved the highest processing rate when compared to related works in the literature. This high processing rate was obtained designing an architecture with a high operation frequency and low numbers of cycles necessary to process each block.

  13. Artifacts in magnetic resonance imaging of the head

    Energy Technology Data Exchange (ETDEWEB)

    Iwama, Toru; Andoh, Takashi; Sakai, Noboru; Yamada, Hiromu [Gifu Univ. (Japan). Faculty of Medicine; Funakoshi, Takashi; Akiyama, Shigeru; Yoshida, Kakuro

    1989-08-01

    The results of 505 magnetic resonance (MR) imaging examinations of the head disclosed several different types of artifact. Various artifacts observed with two-dimentional Fourier transformation are described and illustrated. All images were obtained with a 0.5 Tesla superconducting MR imager. About 70% of all images contained artifacts. Phase encoding artifacts due to motion or flow were most frequently observed. Center, 'zipper,' truncation, radiofrequency, and ferromagnetic artifacts and contrast error on inversion recovery (IR) images were noted less frequently. Phase encoding artifacts and contrast errors on IR images totally degraded the images, and 'zipper' artifacts were regional. Center artifacts resembled small infarctions, and ferromagnetic artifacts sometimes mimicked hematmas. It is important to recognize these artifacts and to devise methods to avoid their influence on the region of interest. (author).

  14. Analysis of clad motion during a loss of flow (LOF) accident in a fast sodium cooled reactor

    International Nuclear Information System (INIS)

    Henkel, P.

    1985-10-01

    A new model describing clad motion during a Loss of Flow (LOF) accident in a Liquid Metal Cooled Fast (Breeder) Reactor (LMFBR) is presented. Its special features are Clad motion is treated within a fuel pin bundle. The bundle geometry is represented by an equivalent annular geometry which serves as the descriptional basis for the clad motion analysis; Several flow regimes are considered. These include a wave or film flow along the fuel pin surfaces as well as a drop flow within the coolant channels. A new entrainment criterion is successfully applied to describe the entrainment of molten cladding and the coolant flow is modelled as a two-dimensional, monstationary flow. Therefore, radial cross flows in a pin bundle can be calculated. Especially, thermal incoherency effects can be treated consistently. The analysis of clad motion in the two experiments STAR1 and STAR2 using the subsequently presented SANDCMOT model gives good agreement with the experimental data. (orig.) [de

  15. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  16. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  17. Fast filtering algorithm based on vibration systems and neural information exchange and its application to micro motion robot

    International Nuclear Information System (INIS)

    Gao Wa; Zha Fu-Sheng; Li Man-Tian; Song Bao-Yu

    2014-01-01

    This paper develops a fast filtering algorithm based on vibration systems theory and neural information exchange approach. The characters, including the derivation process and parameter analysis, are discussed and the feasibility and the effectiveness are testified by the filtering performance compared with various filtering methods, such as the fast wavelet transform algorithm, the particle filtering method and our previously developed single degree of freedom vibration system filtering algorithm, according to simulation and practical approaches. Meanwhile, the comparisons indicate that a significant advantage of the proposed fast filtering algorithm is its extremely fast filtering speed with good filtering performance. Further, the developed fast filtering algorithm is applied to the navigation and positioning system of the micro motion robot, which is a high real-time requirement for the signals preprocessing. Then, the preprocessing data is used to estimate the heading angle error and the attitude angle error of the micro motion robot. The estimation experiments illustrate the high practicality of the proposed fast filtering algorithm. (general)

  18. Motion-based, high-yielding, and fast separation of different charged organics in water.

    Science.gov (United States)

    Xuan, Mingjun; Lin, Xiankun; Shao, Jingxin; Dai, Luru; He, Qiang

    2015-01-12

    We report a self-propelled Janus silica micromotor as a motion-based analytical method for achieving fast target separation of polyelectrolyte microcapsules, enriching different charged organics with low molecular weights in water. The self-propelled Janus silica micromotor catalytically decomposes a hydrogen peroxide fuel and moves along the direction of the catalyst face at a speed of 126.3 μm s(-1) . Biotin-functionalized Janus micromotors can specifically capture and rapidly transport streptavidin-modified polyelectrolyte multilayer capsules, which could effectively enrich and separate different charged organics in water. The interior of the polyelectrolyte multilayer microcapsules were filled with a strong charged polyelectrolyte, and thus a Donnan equilibrium is favorable between the inner solution within the capsules and the bulk solution to entrap oppositely charged organics in water. The integration of these self-propelled Janus silica micromotors and polyelectrolyte multilayer capsules into a lab-on-chip device that enables the separation and analysis of charged organics could be attractive for a diverse range of applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. FAST MOTIONS OF GALAXIES IN THE COMA I CLOUD: A CASE OF DARK ATTRACTOR?

    International Nuclear Information System (INIS)

    Karachentsev, Igor D.; Nasonova, Olga G.; Courtois, Helene M.

    2011-01-01

    We note that nearby galaxies having high negative peculiar velocities are distributed over the sky very inhomogeneously. A part of this anisotropy is caused by the 'Local Velocity Anomaly', i.e., by the bulk motion of nearby galaxies away from the Local Void. However, half of the fast-flying objects reside within a small region known as the Coma I cloud. According to Makarov and Karachentsev, this complex contains 8 groups, 5 triplets, 10 pairs, and 83 single galaxies with a total mass of 4.7 × 10 13 M ☉ . We use 122 galaxies in the Coma I region with known distances and radial velocities V LG –1 to draw the Hubble relation for them. The Hubble diagram shows a Z-shaped effect of infall with an amplitude of +200 km s –1 on the nearby side and –700 km s –1 on the back side. This phenomenon can be understood as the galaxy infall toward a dark attractor with a mass of ∼2 × 10 14 M ☉ situated at a distance of 15 Mpc from us. The existence of a large void between the Coma and Virgo clusters also probably affects the Hubble flow around the Coma I.

  20. Dynamic motion analysis of fetuses with central nervous system disorders by cine magnetic resonance imaging using fast imaging employing steady-state acquisition and parallel imaging: a preliminary result.

    Science.gov (United States)

    Guo, Wan-Yuo; Ono, Shigeki; Oi, Shizuo; Shen, Shu-Huei; Wong, Tai-Tong; Chung, Hsiao-Wen; Hung, Jeng-Hsiu

    2006-08-01

    The authors present a novel cine magnetic resonance (MR) imaging, two-dimensional (2D) fast imaging employing steady-state acquisition (FIESTA) technique with parallel imaging. It achieves temporal resolution at less than half a second as well as high spatial resolution cine imaging free of motion artifacts for evaluating the dynamic motion of fetuses in utero. The information obtained is used to predict postnatal outcome. Twenty-five fetuses with anomalies were studied. Ultrasonography demonstrated severe abnormalities in five of the fetuses; the other 20 fetuses constituted a control group. The cine fetal MR imaging demonstrated fetal head, neck, trunk, extremity, and finger as well as swallowing motions. Imaging findings were evaluated and compared in fetuses with major central nervous system (CNS) anomalies in five cases and minor CNS, non-CNS, or no anomalies in 20 cases. Normal motility was observed in the latter group. For fetuses in the former group, those with abnormal motility failed to survive after delivery, whereas those with normal motility survived with functioning preserved. The power deposition of radiofrequency, presented as specific absorption rate (SAR), was calculated. The SAR of FIESTA was approximately 13 times lower than that of conventional MR imaging of fetuses obtained using single-shot fast spin echo sequences. The following conclusions are drawn: 1) Fetal motion is no longer a limitation for prenatal imaging after the implementation of parallel imaging with 2D FIESTA, 2) Cine MR imaging illustrates fetal motion in utero with high clinical reliability, 3) For cases involving major CNS anomalies, cine MR imaging provides information on extremity motility in fetuses and serves as a prognostic indicator of postnatal outcome, and 4) The cine MR used to observe fetal activity is technically 2D and conceptually three-dimensional. It provides four-dimensional information for making proper and timely obstetrical and/or postnatal management

  1. Mesoscale hybrid calibration artifact

    Science.gov (United States)

    Tran, Hy D.; Claudet, Andre A.; Oliver, Andrew D.

    2010-09-07

    A mesoscale calibration artifact, also called a hybrid artifact, suitable for hybrid dimensional measurement and the method for make the artifact. The hybrid artifact has structural characteristics that make it suitable for dimensional measurement in both vision-based systems and touch-probe-based systems. The hybrid artifact employs the intersection of bulk-micromachined planes to fabricate edges that are sharp to the nanometer level and intersecting planes with crystal-lattice-defined angles.

  2. Interactive inverse kinematics for human motion estimation

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Hauberg, Søren; Lapuyade, Jerome

    2009-01-01

    We present an application of a fast interactive inverse kinematics method as a dimensionality reduction for monocular human motion estimation. The inverse kinematics solver deals efficiently and robustly with box constraints and does not suffer from shaking artifacts. The presented motion...... to significantly speed up the particle filtering. It should be stressed that the observation part of the system has not been our focus, and as such is described only from a sense of completeness. With our approach it is possible to construct a robust and computationally efficient system for human motion estimation....

  3. A novel approach for fast scanning of nuclear emulsions with continuous motion of the microscope stage

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, A., E-mail: andrey@na.infn.it [INFN sezione di Napoli, I-80125 Napoli (Italy); LPI - Lebedev Physical Institute of the Russian Academy of Sciences, RUS-119991 Moscow (Russian Federation); Tioukov, V. [INFN sezione di Napoli, I-80125 Napoli (Italy)

    2013-08-01

    Nuclear emulsions have been used in particle physics experiments for many decades because of their unique spatial resolution. The use of nuclear emulsions as precise tracking detectors in large experiments has recently been made possible due to advances in the production of emulsion films and to the development of very fast automatic scanning devices. The present scanning speed of the European Scanning System (ESS), which has been developed within the OPERA Collaboration, is about 20 cm{sup 2}/h. In addition to the scanning of OPERA films, the ESS is used for other applications with ever-growing demands for scanning speed, such as the muon radiography of volcanoes. In order to further increase the scanning speed of the ESS, we are testing a novel approach different from the standard stop-and-go motion of the microscope stage in the horizontal plane. Indeed we perform data acquisition with the stage moving at constant speed, using an objective lens with wide field of view. Unlike the implementation realized in Japan where the movement of objective lens and stage are synchronized to pile up images of the same view in a vertical stack, in this approach only the stage is moving horizontally. Thus images at different depths are not fully overlapped and special care is needed in the reconstruction. This approach can give a substantial increase in the scanning speed, especially for thin emulsion layers and wide field of view. In this paper we demonstrate that, after applying special corrections, the emulsion data quality can be as good as with the standard stop-and-go approach. This technique allows to double the scanning speed of the ESS, bringing it to 40 cm{sup 2}/h without any hardware modification.

  4. Correlation-based motion vector processing with adaptive interpolation scheme for motion-compensated frame interpolation.

    Science.gov (United States)

    Huang, Ai-Mei; Nguyen, Truong

    2009-04-01

    In this paper, we address the problems of unreliable motion vectors that cause visual artifacts but cannot be detected by high residual energy or bidirectional prediction difference in motion-compensated frame interpolation. A correlation-based motion vector processing method is proposed to detect and correct those unreliable motion vectors by explicitly considering motion vector correlation in the motion vector reliability classification, motion vector correction, and frame interpolation stages. Since our method gradually corrects unreliable motion vectors based on their reliability, we can effectively discover the areas where no motion is reliable to be used, such as occlusions and deformed structures. We also propose an adaptive frame interpolation scheme for the occlusion areas based on the analysis of their surrounding motion distribution. As a result, the interpolated frames using the proposed scheme have clearer structure edges and ghost artifacts are also greatly reduced. Experimental results show that our interpolated results have better visual quality than other methods. In addition, the proposed scheme is robust even for those video sequences that contain multiple and fast motions.

  5. Reduced aliasing artifacts using shaking projection k-space sampling trajectory

    Science.gov (United States)

    Zhu, Yan-Chun; Du, Jiang; Yang, Wen-Chao; Duan, Chai-Jie; Wang, Hao-Yu; Gao, Song; Bao, Shang-Lian

    2014-03-01

    Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-T2 imaging. They are less sensitive to flow and motion artifacts, and support fast imaging with short echo times. However, aliasing and streaking artifacts are two main sources which degrade radial imaging quality. For a given fixed number of k-space projections, data distributions along radial and angular directions will influence the level of aliasing and streaking artifacts. Conventional radial k-space sampling trajectory introduces an aliasing artifact at the first principal ring of point spread function (PSF). In this paper, a shaking projection (SP) k-space sampling trajectory was proposed to reduce aliasing artifacts in MR images. SP sampling trajectory shifts the projection alternately along the k-space center, which separates k-space data in the azimuthal direction. Simulations based on conventional and SP sampling trajectories were compared with the same number projections. A significant reduction of aliasing artifacts was observed using the SP sampling trajectory. These two trajectories were also compared with different sampling frequencies. A SP trajectory has the same aliasing character when using half sampling frequency (or half data) for reconstruction. SNR comparisons with different white noise levels show that these two trajectories have the same SNR character. In conclusion, the SP trajectory can reduce the aliasing artifact without decreasing SNR and also provide a way for undersampling reconstruction. Furthermore, this method can be applied to three-dimensional (3D) hybrid or spherical radial k-space sampling for a more efficient reduction of aliasing artifacts.

  6. Reduced aliasing artifacts using shaking projection k-space sampling trajectory

    International Nuclear Information System (INIS)

    Zhu Yan-Chun; Yang Wen-Chao; Wang Hao-Yu; Gao Song; Bao Shang-Lian; Du Jiang; Duan Chai-Jie

    2014-01-01

    Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-T2 imaging. They are less sensitive to flow and motion artifacts, and support fast imaging with short echo times. However, aliasing and streaking artifacts are two main sources which degrade radial imaging quality. For a given fixed number of k-space projections, data distributions along radial and angular directions will influence the level of aliasing and streaking artifacts. Conventional radial k-space sampling trajectory introduces an aliasing artifact at the first principal ring of point spread function (PSF). In this paper, a shaking projection (SP) k-space sampling trajectory was proposed to reduce aliasing artifacts in MR images. SP sampling trajectory shifts the projection alternately along the k-space center, which separates k-space data in the azimuthal direction. Simulations based on conventional and SP sampling trajectories were compared with the same number projections. A significant reduction of aliasing artifacts was observed using the SP sampling trajectory. These two trajectories were also compared with different sampling frequencies. A SP trajectory has the same aliasing character when using half sampling frequency (or half data) for reconstruction. SNR comparisons with different white noise levels show that these two trajectories have the same SNR character. In conclusion, the SP trajectory can reduce the aliasing artifact without decreasing SNR and also provide a way for undersampling reconstruction. Furthermore, this method can be applied to three-dimensional (3D) hybrid or spherical radial k-space sampling for a more efficient reduction of aliasing artifacts

  7. Reduction of vascular artifact on T1-weighted images of the brain by using three-dimensional double IR fast spoiled gradient echo recalled acquisition in the steady state (FSPGR) at 3.0 Tesla

    International Nuclear Information System (INIS)

    Fujiwara, Yasuhiro; Yamaguchi, Isao; Ookoshi, Yusuke; Ootani, Yuriko; Matsuda, Tsuyoshi; Ishimori, Yoshiyuki; Hayashi, Hiroyuki; Miyati, Tosiaki; Kimura, Hirohiko

    2007-01-01

    The purpose of this study was to decrease vascular artifacts caused by the in-flow effect in three-dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady state (3D IR FSPGR) at 3.0 Tesla. We developed 3D double IR FSPGR and investigated the signal characteristics of the new sequence. The 3D double IR FSPGR sequence uses two inversion pulses, the first for obtaining tissue contrast and the second for nulling vascular signal, which is applied at the time of the first IR period at the neck region. We have optimized scan parameters based on both phantom and in-vivo study. As a result, optimized parameters (1st TI=700 ms, 2nd TI=400 ms) successfully have produced much less vessel signal at reduction than conventional 3D IR FSPGR over a wide imaging range, while preserving the signal-to-noise ratio (SNR) and gray/white matter contrast. Moreover, the decreased artifact was also confirmed by visual inspection of the images obtained in vivo using those parameters. Thus, 3D double IR FSPGR was a useful sequence for the acquisition of T1-weighted images at 3.0 Tesla. (author)

  8. Stopping power and polarization induced in a plasma by a fast charged particle in circular motion

    Energy Technology Data Exchange (ETDEWEB)

    Villo-Perez, Isidro [Departamento de Electronica, Tecnologia de las Computadoras y Proyectos, Universidad Politecnica de Cartagena, Cartagena (Spain); Arista, Nestor R. [Division Colisiones Atomicas, Centro Atomico Bariloche and Instituto Balseiro, Comision Nacional de Energia Atomica, Bariloche (Argentina); Garcia-Molina, Rafael [Departamento de Fisica, Universidad de Murcia, Murcia (Spain)

    2002-03-28

    We describe the perturbation induced in a plasma by a charged particle in circular motion, analysing in detail the evolution of the induced charge, the electrostatic potential and the energy loss of the particle. We describe the initial transitory behaviour and the different ways in which convergence to final stationary solutions may be obtained depending on the basic parameters of the problem. The results for the stopping power show a resonant behaviour which may give place to large stopping enhancement values as compared with the case of particles in straight-line motion with the same linear velocity. The results also explain a resonant effect recently obtained for particles in circular motion in magnetized plasmas. (author)

  9. Motion in radiotherapy

    DEFF Research Database (Denmark)

    Korreman, Stine Sofia

    2012-01-01

    This review considers the management of motion in photon radiation therapy. An overview is given of magnitudes and variability of motion of various structures and organs, and how the motion affects images by producing artifacts and blurring. Imaging of motion is described, including 4DCT and 4DPE...

  10. Improving the use of principal component analysis to reduce physiological noise and motion artifacts to increase the sensitivity of task-based fMRI.

    Science.gov (United States)

    Soltysik, David A; Thomasson, David; Rajan, Sunder; Biassou, Nadia

    2015-02-15

    Functional magnetic resonance imaging (fMRI) time series are subject to corruption by many noise sources, especially physiological noise and motion. Researchers have developed many methods to reduce physiological noise, including RETROICOR, which retroactively removes cardiac and respiratory waveforms collected during the scan, and CompCor, which applies principal components analysis (PCA) to remove physiological noise components without any physiological monitoring during the scan. We developed four variants of the CompCor method. The optimized CompCor method applies PCA to time series in a noise mask, but orthogonalizes each component to the BOLD response waveform and uses an algorithm to determine a favorable number of components to use as "nuisance regressors." Whole brain component correction (WCompCor) is similar, except that it applies PCA to time-series throughout the whole brain. Low-pass component correction (LCompCor) identifies low-pass filtered components throughout the brain, while high-pass component correction (HCompCor) identifies high-pass filtered components. We compared the new methods with the original CompCor method by examining the resulting functional contrast-to-noise ratio (CNR), sensitivity, and specificity. (1) The optimized CompCor method increased the CNR and sensitivity compared to the original CompCor method and (2) the application of WCompCor yielded the best improvement in the CNR and sensitivity. The sensitivity of the optimized CompCor, WCompCor, and LCompCor methods exceeded that of the original CompCor method. However, regressing noise signals showed a paradoxical consequence of reducing specificity for all noise reduction methods attempted. Published by Elsevier B.V.

  11. Fetal anatomy revealed with fast MR sequences.

    Science.gov (United States)

    Levine, D; Hatabu, H; Gaa, J; Atkinson, M W; Edelman, R R

    1996-10-01

    Although all the imaging studies in this pictorial essay were done for maternal rather than fetal indications, fetal anatomy was well visualized. However, when scans are undertaken for fetal indications, fetal motion in between scout views and imaging sequences may make specific image planes difficult to obtain. Of the different techniques described in this review, we preferred the HASTE technique and use it almost exclusively for scanning pregnant patients. The T2-weighting is ideal for delineating fetal organs. Also, the HASTE technique allows images to be obtained in 430 msec, limiting artifacts arising from maternal and fetal motion. MR imaging should play a more important role in evaluating equivocal sonographic cases as fast scanning techniques are more widely used. Obstetric MR imaging no longer will be limited by fetal motion artifacts. When complex anatomy requires definition in a complicated pregnant patient, MR imaging should be considered as a useful adjunct to sonography.

  12. Artifacts that mimic ballistic magnetoresistance

    International Nuclear Information System (INIS)

    Egelhoff, W.F. . E-mail : egelhoff@nist.gov; Gan, L.; Ettedgui, H.; Kadmon, Y.; Powell, C.J.; Chen, P.J.; Shapiro, A.J.; McMichael, R.D.; Mallett, J.J.; Moffat, T.P.; Stiles, M.D.; Svedberg, E.B.

    2005-01-01

    We have investigated the circumstances underlying recent reports of very large values of ballistic magnetoresistance (BMR) in nanocontacts between magnetic wires. We find that the geometries used are subject to artifacts due to motion of the wires that distort the nanocontact thereby changing its electrical resistance. Since these nanocontacts are often of atomic scale, reliable experiments would require stability on the atomic scale. No method for achieving such stability in macroscopic wires is apparent. We conclude that macroscopic magnetic wires cannot be used to establish the validity of the BMR effect

  13. Complexity reduction in the H.264/AVC using highly adaptive fast mode decision based on macroblock motion activity

    Science.gov (United States)

    Abdellah, Skoudarli; Mokhtar, Nibouche; Amina, Serir

    2015-11-01

    The H.264/AVC video coding standard is used in a wide range of applications from video conferencing to high-definition television according to its high compression efficiency. This efficiency is mainly acquired from the newly allowed prediction schemes including variable block modes. However, these schemes require a high complexity to select the optimal mode. Consequently, complexity reduction in the H.264/AVC encoder has recently become a very challenging task in the video compression domain, especially when implementing the encoder in real-time applications. Fast mode decision algorithms play an important role in reducing the overall complexity of the encoder. In this paper, we propose an adaptive fast intermode algorithm based on motion activity, temporal stationarity, and spatial homogeneity. This algorithm predicts the motion activity of the current macroblock from its neighboring blocks and identifies temporal stationary regions and spatially homogeneous regions using adaptive threshold values based on content video features. Extensive experimental work has been done in high profile, and results show that the proposed source-coding algorithm effectively reduces the computational complexity by 53.18% on average compared with the reference software encoder, while maintaining the high-coding efficiency of H.264/AVC by incurring only 0.097 dB in total peak signal-to-noise ratio and 0.228% increment on the total bit rate.

  14. Fast Computation of Ground Motion Shaking Map base on the Modified Stochastic Finite Fault Modeling

    Science.gov (United States)

    Shen, W.; Zhong, Q.; Shi, B.

    2012-12-01

    Rapidly regional MMI mapping soon after a moderate-large earthquake is crucial to loss estimation, emergency services and planning of emergency action by the government. In fact, many countries show different degrees of attention on the technology of rapid estimation of MMI , and this technology has made significant progress in earthquake-prone countries. In recent years, numerical modeling of strong ground motion has been well developed with the advances of computation technology and earthquake science. The computational simulation of strong ground motion caused by earthquake faulting has become an efficient way to estimate the regional MMI distribution soon after earthquake. In China, due to the lack of strong motion observation in network sparse or even completely missing areas, the development of strong ground motion simulation method has become an important means of quantitative estimation of strong motion intensity. In many of the simulation models, stochastic finite fault model is preferred to rapid MMI estimating for its time-effectiveness and accuracy. In finite fault model, a large fault is divided into N subfaults, and each subfault is considered as a small point source. The ground motions contributed by each subfault are calculated by the stochastic point source method which is developed by Boore, and then summed at the observation point to obtain the ground motion from the entire fault with a proper time delay. Further, Motazedian and Atkinson proposed the concept of Dynamic Corner Frequency, with the new approach, the total radiated energy from the fault and the total seismic moment are conserved independent of subfault size over a wide range of subfault sizes. In current study, the program EXSIM developed by Motazedian and Atkinson has been modified for local or regional computations of strong motion parameters such as PGA, PGV and PGD, which are essential for MMI estimating. To make the results more reasonable, we consider the impact of V30 for the

  15. Small Artifacts - Big Technologies

    DEFF Research Database (Denmark)

    Kreiner, Kristian

    2005-01-01

    The computer IC is the heart of the information and telecommunication technology. It is a tiny artifact, but with incredible organizing powers. We use this physical artifact as the location for studying central problems of the knowledge economy. First, the paper describes the history of chip design...

  16. Transient feedback from fuel motion in metal IFR [Integral Fast Reactor] fuel

    International Nuclear Information System (INIS)

    Rhodes, E.A.; Stanford, G.S.; Regis, J.P.; Bauer, T.H.; Dickerman, C.E.

    1990-01-01

    Results from hodoscope data analyses are presented for TREAT transient-overpower tests M5 through M7 with emphasis on transient feedback mechanisms, including prefailure expansion at the tops of the fuel pins, subsequent dispersive axial fuel motion, and losses in relative worth of the fuel pins during the tests. Tests M5 and M6 were the first TOP tests of margin to cladding branch and prefailure elongation of D9-clad ternary (U-Pu-Zr) IFR-type fuel. Test M7 extended these results to high-burnup fuel and also initiated transient testing of HT9-clad binary (U-Zr) FFTF-driver fuel. Results show significant prefailure negative reactivity feedback and strongly negative feedback from fuel driven to failure. 4 refs., 6 figs

  17. A High-Speed Vision-Based Sensor for Dynamic Vibration Analysis Using Fast Motion Extraction Algorithms

    Directory of Open Access Journals (Sweden)

    Dashan Zhang

    2016-04-01

    Full Text Available The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.

  18. Slow speed—fast motion: time-lapse recordings in physics education

    Science.gov (United States)

    Vollmer, Michael; Möllmann, Klaus-Peter

    2018-05-01

    Video analysis with a 30 Hz frame rate is the standard tool in physics education. The development of affordable high-speed-cameras has extended the capabilities of the tool for much smaller time scales to the 1 ms range, using frame rates of typically up to 1000 frames s-1, allowing us to study transient physics phenomena happening too fast for the naked eye. Here we want to extend the range of phenomena which may be studied by video analysis in the opposite direction by focusing on much longer time scales ranging from minutes, hours to many days or even months. We discuss this time-lapse method, needed equipment and give a few hints of how to produce respective recordings for two specific experiments.

  19. Motion compensated digital tomosynthesis

    NARCIS (Netherlands)

    van der Reijden, Anneke; van Herk, Marcel; Sonke, Jan-Jakob

    2013-01-01

    Digital tomosynthesis (DTS) is a limited angle image reconstruction method for cone beam projections that offers patient surveillance capabilities during VMAT based SBRT delivery. Motion compensation (MC) has the potential to mitigate motion artifacts caused by respiratory motion, such as blur. The

  20. FAST

    DEFF Research Database (Denmark)

    Zuidmeer-Jongejan, Laurian; Fernandez-Rivas, Montserrat; Poulsen, Lars K.

    2012-01-01

    ABSTRACT: The FAST project (Food Allergy Specific Immunotherapy) aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT), using subcutaneous injections with aqu...

  1. Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the same radiation dose: Comparison of motion artifacts, diagnostic confidence and signal-to-noise-ratios

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger E.; Stadler, Alfred; Beitzke, Dietrich; Homolka, Peter; Weber, Michael; Lammer, Johannes; Czerny, Martin; Loewe, Christian

    2012-01-01

    Purpose: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). Materials and methods: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. Results: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p < 0.001) and DC (p < 0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p < 0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p < 0.001), but not a statistically significant higher DC (p = 0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p = 0.861 and 0.526, respectively) and DC (p = 1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24 mSv; range, 18.43–25.94 mSv) did not differ significantly (p = 0.051) from that of non-gated CT angiography (24.28 mSv; range, 19.37–29.27 mSv). Conclusion: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.

  2. The Information Systems Artifact

    DEFF Research Database (Denmark)

    Chatterjee, Surtirtha; Xiao, Xiao; Elbanna, Amany

    2017-01-01

    Passionate debates regarding the defining characteristic of the “IT artifact” continue. Such debates, and also the lack of explicit consideration of the “information” element in the IT artifact, motivate us to propose a revised conception, drawing upon concepts from General Systems Theory (GST). ...

  3. PROMO – Real-time Prospective Motion Correction in MRI using Image-based Tracking

    Science.gov (United States)

    White, Nathan; Roddey, Cooper; Shankaranarayanan, Ajit; Han, Eric; Rettmann, Dan; Santos, Juan; Kuperman, Josh; Dale, Anders

    2010-01-01

    Artifacts caused by patient motion during scanning remain a serious problem in most MRI applications. The prospective motion correction technique attempts to address this problem at its source by keeping the measurement coordinate system fixed with respect to the patient throughout the entire scan process. In this study, a new image-based approach for prospective motion correction is described, which utilizes three orthogonal 2D spiral navigator acquisitions (SP-Navs) along with a flexible image-based tracking method based on the Extended Kalman Filter (EKF) algorithm for online motion measurement. The SP-Nav/EKF framework offers the advantages of image-domain tracking within patient-specific regions-of-interest and reduced sensitivity to off-resonance-induced corruption of rigid-body motion estimates. The performance of the method was tested using offline computer simulations and online in vivo head motion experiments. In vivo validation results covering a broad range of staged head motions indicate a steady-state error of the SP-Nav/EKF motion estimates of less than 10 % of the motion magnitude, even for large compound motions that included rotations over 15 degrees. A preliminary in vivo application in 3D inversion recovery spoiled gradient echo (IR-SPGR) and 3D fast spin echo (FSE) sequences demonstrates the effectiveness of the SP-Nav/EKF framework for correcting 3D rigid-body head motion artifacts prospectively in high-resolution 3D MRI scans. PMID:20027635

  4. Optimization of intra-voxel incoherent motion imaging at 3.0 Tesla for fast liver examination.

    Science.gov (United States)

    Leporq, Benjamin; Saint-Jalmes, Hervé; Rabrait, Cecile; Pilleul, Frank; Guillaud, Olivier; Dumortier, Jérôme; Scoazec, Jean-Yves; Beuf, Olivier

    2015-05-01

    Optimization of multi b-values MR protocol for fast intra-voxel incoherent motion imaging of the liver at 3.0 Tesla. A comparison of four different acquisition protocols were carried out based on estimated IVIM (DSlow , DFast , and f) and ADC-parameters in 25 healthy volunteers. The effects of respiratory gating compared with free breathing acquisition then diffusion gradient scheme (simultaneous or sequential) and finally use of weighted averaging for different b-values were assessed. An optimization study based on Cramer-Rao lower bound theory was then performed to minimize the number of b-values required for a suitable quantification. The duration-optimized protocol was evaluated on 12 patients with chronic liver diseases No significant differences of IVIM parameters were observed between the assessed protocols. Only four b-values (0, 12, 82, and 1310 s.mm(-2) ) were found mandatory to perform a suitable quantification of IVIM parameters. DSlow and DFast significantly decreased between nonadvanced and advanced fibrosis (P < 0.05 and P < 0.01) whereas perfusion fraction and ADC variations were not found to be significant. Results showed that IVIM could be performed in free breathing, with a weighted-averaging procedure, a simultaneous diffusion gradient scheme and only four optimized b-values (0, 10, 80, and 800) reducing scan duration by a factor of nine compared with a nonoptimized protocol. Preliminary results have shown that parameters such as DSlow and DFast based on optimized IVIM protocol can be relevant biomarkers to distinguish between nonadvanced and advanced fibrosis. © 2014 Wiley Periodicals, Inc.

  5. Motion compensation in digital subtraction angiography using graphics hardware.

    Science.gov (United States)

    Deuerling-Zheng, Yu; Lell, Michael; Galant, Adam; Hornegger, Joachim

    2006-07-01

    An inherent disadvantage of digital subtraction angiography (DSA) is its sensitivity to patient motion which causes artifacts in the subtraction images. These artifacts could often reduce the diagnostic value of this technique. Automated, fast and accurate motion compensation is therefore required. To cope with this requirement, we first examine a method explicitly designed to detect local motions in DSA. Then, we implement a motion compensation algorithm by means of block matching on modern graphics hardware. Both methods search for maximal local similarity by evaluating a histogram-based measure. In this context, we are the first who have mapped an optimizing search strategy on graphics hardware while paralleling block matching. Moreover, we provide an innovative method for creating histograms on graphics hardware with vertex texturing and frame buffer blending. It turns out that both methods can effectively correct the artifacts in most case, as the hardware implementation of block matching performs much faster: the displacements of two 1024 x 1024 images can be calculated at 3 frames/s with integer precision or 2 frames/s with sub-pixel precision. Preliminary clinical evaluation indicates that the computation with integer precision could already be sufficient.

  6. An Additive Manufacturing Test Artifact

    Science.gov (United States)

    Moylan, Shawn; Slotwinski, John; Cooke, April; Jurrens, Kevin; Donmez, M Alkan

    2014-01-01

    A test artifact, intended for standardization, is proposed for the purpose of evaluating the performance of additive manufacturing (AM) systems. A thorough analysis of previously proposed AM test artifacts as well as experience with machining test artifacts have inspired the design of the proposed test artifact. This new artifact is designed to provide a characterization of the capabilities and limitations of an AM system, as well as to allow system improvement by linking specific errors measured in the test artifact to specific sources in the AM system. The proposed test artifact has been built in multiple materials using multiple AM technologies. The results of several of the builds are discussed, demonstrating how the measurement results can be used to characterize and improve a specific AM system. PMID:26601039

  7. The Human-Artifact Model

    DEFF Research Database (Denmark)

    Bødker, Susanne; Klokmose, Clemens Nylandsted

    2011-01-01

    Although devices of all shapes and sizes currently dominate the technological landscape, human–computer interaction (HCI) as a field is not yet theoretically equipped to match this reality. In this article we develop the human–artifact model, which has its roots in activity theoretical HCI....... By reinterpreting the activity theoretical foundation, we present a framework that helps addressing the analysis of individual interactive artifacts while embracing that they are part of a larger ecology of artifacts. We show how the human–artifact model helps structuring the understanding of an artifact's action......-possibilities in relation to the artifact ecology surrounding it. Essential to the model is that it provides four interconnected levels of analysis and addresses the possibilities and problems at these four levels. Artifacts and their use are constantly developing, and we address development in, and of, use. The framework...

  8. Fast generation of video holograms of three-dimensional moving objects using a motion compensation-based novel look-up table.

    Science.gov (United States)

    Kim, Seung-Cheol; Dong, Xiao-Bin; Kwon, Min-Woo; Kim, Eun-Soo

    2013-05-06

    A novel approach for fast generation of video holograms of three-dimensional (3-D) moving objects using a motion compensation-based novel-look-up-table (MC-N-LUT) method is proposed. Motion compensation has been widely employed in compression of conventional 2-D video data because of its ability to exploit high temporal correlation between successive video frames. Here, this concept of motion-compensation is firstly applied to the N-LUT based on its inherent property of shift-invariance. That is, motion vectors of 3-D moving objects are extracted between the two consecutive video frames, and with them motions of the 3-D objects at each frame are compensated. Then, through this process, 3-D object data to be calculated for its video holograms are massively reduced, which results in a dramatic increase of the computational speed of the proposed method. Experimental results with three kinds of 3-D video scenarios reveal that the average number of calculated object points and the average calculation time for one object point of the proposed method, have found to be reduced down to 86.95%, 86.53% and 34.99%, 32.30%, respectively compared to those of the conventional N-LUT and temporal redundancy-based N-LUT (TR-N-LUT) methods.

  9. Rolling Shutter Motion Deblurring

    KAUST Repository

    Su, Shuochen

    2015-06-07

    Although motion blur and rolling shutter deformations are closely coupled artifacts in images taken with CMOS image sensors, the two phenomena have so far mostly been treated separately, with deblurring algorithms being unable to handle rolling shutter wobble, and rolling shutter algorithms being incapable of dealing with motion blur. We propose an approach that delivers sharp and undis torted output given a single rolling shutter motion blurred image. The key to achieving this is a global modeling of the camera motion trajectory, which enables each scanline of the image to be deblurred with the corresponding motion segment. We show the results of the proposed framework through experiments on synthetic and real data.

  10. Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts.

    Science.gov (United States)

    Obata, Takayuki; Uemura, Koji; Nonaka, Hiroi; Tamura, Mitsuru; Tanada, Shuji; Ikehira, Hiroo

    2006-01-01

    To acquire high-resolution magnetic resonance (MR) images, we developed a new blinking artifact reduced pulse (BARP) sequence with a surface coil specialized for microscopic imaging (47 mm in diameter). To reduce eye movement, we ascertained that the subjects' eyes were kept open and fixated to the target in the 1.5-T MR gantry. To reduce motion artifacts from blinking, we inserted rest periods for blinking (1.5 s within every 5 s) during MR scanning (T2-weighted fast spin echo; repetition time, 5 s; echo time, 100 ms; echo train, 11; matrix, 256 x 128; field of view, 5 cm; 1-mm thickness x 30 slices). Three scans (100 s x 3) were performed for each normal subject, and they were added together after automatic adjustment for location to reduce quality loss caused by head motion. T2-weighted MR images were acquired with a high resolution and a high signal-to-noise ratio. Motion artifacts were reduced with BARP, as compared with those with random blinking. Intraocular structures such as the iris and ciliary muscles were clearly visualized. Because the whole eye can be covered with a 1-mm thickness by this method, three-dimensional maps can easily be generated from the obtained images. The application of BARP with a surface coil of the human eye might become a useful and widely adopted procedure for MR microimaging.

  11. A generic EEG artifact removal algorithm based on the multi-channel Wiener filter

    Science.gov (United States)

    Somers, Ben; Francart, Tom; Bertrand, Alexander

    2018-06-01

    Objective. The electroencephalogram (EEG) is an essential neuro-monitoring tool for both clinical and research purposes, but is susceptible to a wide variety of undesired artifacts. Removal of these artifacts is often done using blind source separation techniques, relying on a purely data-driven transformation, which may sometimes fail to sufficiently isolate artifacts in only one or a few components. Furthermore, some algorithms perform well for specific artifacts, but not for others. In this paper, we aim to develop a generic EEG artifact removal algorithm, which allows the user to annotate a few artifact segments in the EEG recordings to inform the algorithm. Approach. We propose an algorithm based on the multi-channel Wiener filter (MWF), in which the artifact covariance matrix is replaced by a low-rank approximation based on the generalized eigenvalue decomposition. The algorithm is validated using both hybrid and real EEG data, and is compared to other algorithms frequently used for artifact removal. Main results. The MWF-based algorithm successfully removes a wide variety of artifacts with better performance than current state-of-the-art methods. Significance. Current EEG artifact removal techniques often have limited applicability due to their specificity to one kind of artifact, their complexity, or simply because they are too ‘blind’. This paper demonstrates a fast, robust and generic algorithm for removal of EEG artifacts of various types, i.e. those that were annotated as unwanted by the user.

  12. From Ecological Sounding Artifacts Towards Sonic Artifact Ecologies

    DEFF Research Database (Denmark)

    Erkut, Cumhur; Serafin, Stefania

    2016-01-01

    The discipline of sonic interaction design has been focused on the interaction between a single user and an artifact. This strongly limits one of the fundamental aspects of music as a social and interactive experience. In this paper we propose sonic artifact ecologies as a mean to examine interac...

  13. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    DEFF Research Database (Denmark)

    Domenici, Paolo; Norin, Tommy; Bushnell, Peter G.

    2015-01-01

    Fast-starts are brief accelerations commonly observed in fish within the context of predator–prey interactions. In typical C-start escape responses, fish react to a threatening stimulus by bending their body into a C-shape during the first muscle contraction (i.e. stage 1) which provides a sudden......-breathing in this species is followed by escape-like C-start motions, presumably to minimise time at the surface and exposure to avian predators. These findings show that C-starts can occur in a variety of contexts in which fish may need to get away from areas of potential danger....

  14. SU-E-J-115: Correlation of Displacement Vector Fields Calculated by Deformable Image Registration Algorithms with Motion Parameters of CT Images with Well-Defined Targets and Controlled-Motion

    Energy Technology Data Exchange (ETDEWEB)

    Jaskowiak, J; Ahmad, S; Ali, I [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Alsbou, N [Ohio Northern University, Ada, OH (United States)

    2015-06-15

    Purpose: To investigate correlation of displacement vector fields (DVF) calculated by deformable image registration algorithms with motion parameters in helical axial and cone-beam CT images with motion artifacts. Methods: A mobile thorax phantom with well-known targets with different sizes that were made from water-equivalent material and inserted in foam to simulate lung lesions. The thorax phantom was imaged with helical, axial and cone-beam CT. The phantom was moved with a cyclic motion with different motion amplitudes and frequencies along the superior-inferior direction. Different deformable image registration algorithms including demons, fast demons, Horn-Shunck and iterative-optical-flow from the DIRART software were used to deform CT images for the phantom with different motion patterns. The CT images of the mobile phantom were deformed to CT images of the stationary phantom. Results: The values of displacement vectors calculated by deformable image registration algorithm correlated strongly with motion amplitude where large displacement vectors were calculated for CT images with large motion amplitudes. For example, the maximal displacement vectors were nearly equal to the motion amplitudes (5mm, 10mm or 20mm) at interfaces between the mobile targets lung tissue, while the minimal displacement vectors were nearly equal to negative the motion amplitudes. The maximal and minimal displacement vectors matched with edges of the blurred targets along the Z-axis (motion-direction), while DVF’s were small in the other directions. This indicates that the blurred edges by phantom motion were shifted largely to match with the actual target edge. These shifts were nearly equal to the motion amplitude. Conclusions: The DVF from deformable-image registration algorithms correlated well with motion amplitude of well-defined mobile targets. This can be used to extract motion parameters such as amplitude. However, as motion amplitudes increased, image artifacts increased

  15. CAMDYN: a new model to describe the axial motion of molten fuel inside the pin of a fast breeder reactor during accident conditions

    International Nuclear Information System (INIS)

    Peter, G.

    1991-01-01

    The new in-pin fuel motion model CAMDYN (Cavity Material Dynamics) describes the axial motion of both partially and fully molten fuel inside the pin of a fast breeder reactor during accident conditions. The motion of the two types of molten fuel and the imbedded fission gas bubbles is treated both before and after cladding failure. The basic modelling approach consists of the treatment of two one-dimensional flows which are coupled by interaction terms. Each of these flows is treated compressively and with axially variable flow cross sections. The mass and energy equations of both fields are solved explicitly using upwind differencing on a fixed Eulerian grid. The two momentum equations are solved simultaneously, using the convective momentum fluxes of the previous timestep. Both partially and fully molten fuel can move axially into a central hole extending to the plenum in the case of certain hollow pellet designs. The fuel temperature calculation includes the determination of a radial temperature profile. A simple conduction freezing model is included. After cladding failure, ejection into the coolant channel is modeled

  16. Turquoise Artifact from Teotihuacan

    Energy Technology Data Exchange (ETDEWEB)

    Spence, Michael W.; Harbottle, Garman; Weigand, Phil C.

    1999-07-01

    Turquoise artifacts appeared sporadically in Mesoamerica as early as the Formative period (Merry de Morales 1987:100, Figure 8.4; Weigand 1989:43). Most occurrences, however, postdate the collapse of Teotihuacan. In the Late Classic and Postclassic periods increasing quantities are found, often in the form of elaborate mosaics, in a wide variety of contexts in central, west and northwest Mexico. Neutron activation analysis has determined that much of this turquoise derives from sources in the southwestern United States (Weigand et al. 1977; Harbottle and Weigand 1992; Weigand and Harbottle 1993). Teotihuacan played a major role in Mesoamerica during the Terminal Formative and Early-Middle Classic periods. It was the dominant power in central Mexico from about the time of Christ to its collapse at about A.D. 650 (Millon 1988, 1992; Cowgill 1996). Throughout this period goods flowed into Teotihuacan from many parts of the Mesoamerican world. Despite this widespread economic interaction, only two pieces of turquoise have been recovered in the city. In the following pages, the context and implications of one of these finds will be examined.

  17. Complexity Control of Fast Motion Estimation in H.264/MPEG-4 AVC with Rate-Distortion-Complexity optimization

    DEFF Research Database (Denmark)

    Wu, Mo; Forchhammer, Søren; Aghito, Shankar Manuel

    2007-01-01

    A complexity control algorithm for H.264 advanced video coding is proposed. The algorithm can control the complexity of integer inter motion estimation for a given target complexity. The Rate-Distortion-Complexity performance is improved by a complexity prediction model, simple analysis of the pa...... statistics and a control scheme. The algorithm also works well for scene change condition. Test results for coding interlaced video (720x576 PAL) are reported.......A complexity control algorithm for H.264 advanced video coding is proposed. The algorithm can control the complexity of integer inter motion estimation for a given target complexity. The Rate-Distortion-Complexity performance is improved by a complexity prediction model, simple analysis of the past...

  18. Successive approximation algorithm for cancellation of artifacts in DSA images

    International Nuclear Information System (INIS)

    Funakami, Raiko; Hiroshima, Kyoichi; Nishino, Junji

    2000-01-01

    In this paper, we propose an algorithm for cancellation of artifacts in DSA images. We have already proposed an automatic registration method based on the detection of local movements. When motion of the object is large, it is difficult to estimate the exact movement, and the cancellation of artifacts may therefore fail. The algorithm we propose here is based on a simple rigid model. We present the results of applying the proposed method to a series of experimental X-ray images, as well as the results of applying the algorithm as preprocessing for a registration method based on local movement. (author)

  19. Investigating media artifacts with children

    DEFF Research Database (Denmark)

    Chimirri, Niklas Alexander

    The dissertation’s aim is to explore the everyday relevance media artifacts have for young children. It discusses and further develops analytical concepts that are committed to taking the children’s perspectives on possibilities and limitations of such artifacts seriously. These conceptual...... developments are rooted in the author’s participation in a daycare practice in Berlin, Germany. The daycare’s situational approach precisely attempted to draw on the children’s everyday life experiences so as to engage in problem-oriented learning projects, on media artifacts and beyond....

  20. Archaic artifacts resembling celestial spheres

    Science.gov (United States)

    Dimitrakoudis, S.; Papaspyrou, P.; Petoussis, V.; Moussas, X.

    We present several bronze artifacts from the Archaic Age in Greece (750-480 BC) that resemble celestial spheres or forms of other astronomical significance. They are studied in the context of the Dark Age transition from Mycenaean Age astronomical themes to the philosophical and practical revival of astronomy in the Classical Age with its plethora of astronomical devices. These artifacts, mostly votive in nature are spherical in shape and appear in a variety of forms their most striking characteristic being the depiction of meridians and/or an equator. Most of those artifacts come from Thessaly, and more specifically from the temple of Itonia Athena at Philia, a religious center of pan-Hellenic significance. Celestial spheres, similar in form to the small artifacts presented in this study, could be used to measure latitudes, or estimate the time at a known place, and were thus very useful in navigation.

  1. Lane Detection in Video-Based Intelligent Transportation Monitoring via Fast Extracting and Clustering of Vehicle Motion Trajectories

    Directory of Open Access Journals (Sweden)

    Jianqiang Ren

    2014-01-01

    Full Text Available Lane detection is a crucial process in video-based transportation monitoring system. This paper proposes a novel method to detect the lane center via rapid extraction and high accuracy clustering of vehicle motion trajectories. First, we use the activity map to realize automatically the extraction of road region, the calibration of dynamic camera, and the setting of three virtual detecting lines. Secondly, the three virtual detecting lines and a local background model with traffic flow feedback are used to extract and group vehicle feature points in unit of vehicle. Then, the feature point groups are described accurately by edge weighted dynamic graph and modified by a motion-similarity Kalman filter during the sparse feature point tracking. After obtaining the vehicle trajectories, a rough k-means incremental clustering with Hausdorff distance is designed to realize the rapid online extraction of lane center with high accuracy. The use of rough set reduces effectively the accuracy decrease, which results from the trajectories that run irregularly. Experimental results prove that the proposed method can detect lane center position efficiently, the affected time of subsequent tasks can be reduced obviously, and the safety of traffic surveillance systems can be enhanced significantly.

  2. ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features.

    Science.gov (United States)

    Mognon, Andrea; Jovicich, Jorge; Bruzzone, Lorenzo; Buiatti, Marco

    2011-02-01

    A successful method for removing artifacts from electroencephalogram (EEG) recordings is Independent Component Analysis (ICA), but its implementation remains largely user-dependent. Here, we propose a completely automatic algorithm (ADJUST) that identifies artifacted independent components by combining stereotyped artifact-specific spatial and temporal features. Features were optimized to capture blinks, eye movements, and generic discontinuities on a feature selection dataset. Validation on a totally different EEG dataset shows that (1) ADJUST's classification of independent components largely matches a manual one by experts (agreement on 95.2% of the data variance), and (2) Removal of the artifacted components detected by ADJUST leads to neat reconstruction of visual and auditory event-related potentials from heavily artifacted data. These results demonstrate that ADJUST provides a fast, efficient, and automatic way to use ICA for artifact removal. Copyright © 2010 Society for Psychophysiological Research.

  3. Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

    Energy Technology Data Exchange (ETDEWEB)

    Rohkohl, Christopher; Bruder, Herbert; Stierstorfer, Karl [Siemens AG, Healthcare Sector, Siemensstrasse 1, 91301 Forchheim (Germany); Flohr, Thomas [Siemens AG, Healthcare Sector, Siemensstrasse 1, 91301 Forchheim (Germany); Institute of Diagnostic Radiology, Eberhard Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)

    2013-03-15

    Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum

  4. Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

    International Nuclear Information System (INIS)

    Rohkohl, Christopher; Bruder, Herbert; Stierstorfer, Karl; Flohr, Thomas

    2013-01-01

    Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum

  5. Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    Science.gov (United States)

    Netherton, Tucker; Li, Yuting; Nitsch, Paige; Shaitelman, Simona; Balter, Peter; Gao, Song; Klopp, Ann; Muruganandham, Manickam; Court, Laurence

    2018-06-01

    Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. To study lung interplay, eight VMAT plans (1-6 arcs) and four-nine-field sliding-window IMRT plans varying in complexity were created. For the breast plans, four-four-field sliding-window IMRT plans were created. Using the Halcyon 1.0 linear accelerator, each plan was delivered five times each under sinusoidal breathing motion to a phantom with 20 implanted MOSFET detectors; MOSFET dose (cGy), delivery time, and MU/cGy values were recorded. Maximum and mean dose deviations were calculated from MOSFET data. The number of MOSFETs with at least 19 of 20 detectors agreeing with their expected dose within 5% per fraction was calculated across 10 6 iterations to model dose deviation as function of fraction number for all plan variants. To put interplay plans into clinical context, additional IMRT and VMAT plans were created and delivered for the sites of head and neck, prostate, whole brain, breast, pelvis, and lung. Average modulation and interplay effect were compared to those from conventional linear accelerators, as reported from previous studies. The mean beam modulation for plans created for the Halcyon 1.0 linear accelerator was 2.9 MU/cGy (two- to four-field IMRT breast plans), 6.2 MU/cGy (at least five-field IMRT), and 3.6 MU/cGy (four-arc VMAT). To achieve treatment plan objectives, Halcyon 1.0 VMAT plans require more arcs and modulation than VMAT on conventional linear accelerators. Maximum and mean dose deviations increased with increasing plan complexity under tumor motion for breast and lung treatments. Concerning VMAT plans under motion, maximum, and mean dose deviations were higher for one arc than for two arcs regardless of plan complexity. For plan variants

  6. A fast band–Krylov eigensolver for macromolecular functional motion simulation on multicore architectures and graphics processors

    Energy Technology Data Exchange (ETDEWEB)

    Aliaga, José I., E-mail: aliaga@uji.es [Depto. Ingeniería y Ciencia de Computadores, Universitat Jaume I, Castellón (Spain); Alonso, Pedro [Departamento de Sistemas Informáticos y Computación, Universitat Politècnica de València (Spain); Badía, José M. [Depto. Ingeniería y Ciencia de Computadores, Universitat Jaume I, Castellón (Spain); Chacón, Pablo [Dept. Biological Chemical Physics, Rocasolano Physics and Chemistry Institute, CSIC, Madrid (Spain); Davidović, Davor [Rudjer Bošković Institute, Centar za Informatiku i Računarstvo – CIR, Zagreb (Croatia); López-Blanco, José R. [Dept. Biological Chemical Physics, Rocasolano Physics and Chemistry Institute, CSIC, Madrid (Spain); Quintana-Ortí, Enrique S. [Depto. Ingeniería y Ciencia de Computadores, Universitat Jaume I, Castellón (Spain)

    2016-03-15

    We introduce a new iterative Krylov subspace-based eigensolver for the simulation of macromolecular motions on desktop multithreaded platforms equipped with multicore processors and, possibly, a graphics accelerator (GPU). The method consists of two stages, with the original problem first reduced into a simpler band-structured form by means of a high-performance compute-intensive procedure. This is followed by a memory-intensive but low-cost Krylov iteration, which is off-loaded to be computed on the GPU by means of an efficient data-parallel kernel. The experimental results reveal the performance of the new eigensolver. Concretely, when applied to the simulation of macromolecules with a few thousands degrees of freedom and the number of eigenpairs to be computed is small to moderate, the new solver outperforms other methods implemented as part of high-performance numerical linear algebra packages for multithreaded architectures.

  7. A fast band–Krylov eigensolver for macromolecular functional motion simulation on multicore architectures and graphics processors

    International Nuclear Information System (INIS)

    Aliaga, José I.; Alonso, Pedro; Badía, José M.; Chacón, Pablo; Davidović, Davor; López-Blanco, José R.; Quintana-Ortí, Enrique S.

    2016-01-01

    We introduce a new iterative Krylov subspace-based eigensolver for the simulation of macromolecular motions on desktop multithreaded platforms equipped with multicore processors and, possibly, a graphics accelerator (GPU). The method consists of two stages, with the original problem first reduced into a simpler band-structured form by means of a high-performance compute-intensive procedure. This is followed by a memory-intensive but low-cost Krylov iteration, which is off-loaded to be computed on the GPU by means of an efficient data-parallel kernel. The experimental results reveal the performance of the new eigensolver. Concretely, when applied to the simulation of macromolecules with a few thousands degrees of freedom and the number of eigenpairs to be computed is small to moderate, the new solver outperforms other methods implemented as part of high-performance numerical linear algebra packages for multithreaded architectures.

  8. Chimeric β-Lactamases: Global Conservation of Parental Function and Fast Time-Scale Dynamics with Increased Slow Motions

    Science.gov (United States)

    Clouthier, Christopher M.; Morin, Sébastien; Gobeil, Sophie M. C.; Doucet, Nicolas; Blanchet, Jonathan; Nguyen, Elisabeth; Gagné, Stéphane M.; Pelletier, Joelle N.

    2012-01-01

    Enzyme engineering has been facilitated by recombination of close homologues, followed by functional screening. In one such effort, chimeras of two class-A β-lactamases – TEM-1 and PSE-4 – were created according to structure-guided protein recombination and selected for their capacity to promote bacterial proliferation in the presence of ampicillin (Voigt et al., Nat. Struct. Biol. 2002 9:553). To provide a more detailed assessment of the effects of protein recombination on the structure and function of the resulting chimeric enzymes, we characterized a series of functional TEM-1/PSE-4 chimeras possessing between 17 and 92 substitutions relative to TEM-1 β-lactamase. Circular dichroism and thermal scanning fluorimetry revealed that the chimeras were generally well folded. Despite harbouring important sequence variation relative to either of the two ‘parental’ β-lactamases, the chimeric β-lactamases displayed substrate recognition spectra and reactivity similar to their most closely-related parent. To gain further insight into the changes induced by chimerization, the chimera with 17 substitutions was investigated by NMR spin relaxation. While high order was conserved on the ps-ns timescale, a hallmark of class A β-lactamases, evidence of additional slow motions on the µs-ms timescale was extracted from model-free calculations. This is consistent with the greater number of resonances that could not be assigned in this chimera relative to the parental β-lactamases, and is consistent with this well-folded and functional chimeric β-lactamase displaying increased slow time-scale motions. PMID:23284969

  9. Artifact detection in electrodermal activity using sparse recovery

    Science.gov (United States)

    Kelsey, Malia; Palumbo, Richard Vincent; Urbaneja, Alberto; Akcakaya, Murat; Huang, Jeannie; Kleckner, Ian R.; Barrett, Lisa Feldman; Quigley, Karen S.; Sejdic, Ervin; Goodwin, Matthew S.

    2017-05-01

    Electrodermal Activity (EDA) - a peripheral index of sympathetic nervous system activity - is a primary measure used in psychophysiology. EDA is widely accepted as an indicator of physiological arousal, and it has been shown to reveal when psychologically novel events occur. Traditionally, EDA data is collected in controlled laboratory experiments. However, recent developments in wireless biosensing have led to an increase in out-of-lab studies. This transition to ambulatory data collection has introduced challenges. In particular, artifacts such as wearer motion, changes in temperature, and electrical interference can be misidentified as true EDA responses. The inability to distinguish artifact from signal hinders analyses of ambulatory EDA data. Though manual procedures for identifying and removing EDA artifacts exist, they are time consuming - which is problematic for the types of longitudinal data sets represented in modern ambulatory studies. This manuscript presents a novel technique to automatically identify and remove artifacts in EDA data using curve fitting and sparse recovery methods. Our method was evaluated using labeled data to determine the accuracy of artifact identification. Procedures, results, conclusions, and future directions are presented.

  10. Fast switching and signature of efficient domain wall motion driven by spin-orbit torques in a perpendicular anisotropy magnetic insulator/Pt bilayer

    Science.gov (United States)

    Avci, Can Onur; Rosenberg, Ethan; Baumgartner, Manuel; Beran, Lukáš; Quindeau, Andy; Gambardella, Pietro; Ross, Caroline A.; Beach, Geoffrey S. D.

    2017-08-01

    We report fast and efficient current-induced switching of a perpendicular anisotropy magnetic insulator thulium iron garnet by using spin-orbit torques (SOT) from the Pt overlayer. We first show that, with quasi-DC (10 ms) current pulses, SOT-induced switching can be achieved with an external field as low as 2 Oe, making TmIG an outstanding candidate to realize efficient switching in heterostructures that produce moderate stray fields without requiring an external field. We then demonstrate deterministic switching with fast current pulses (≤20 ns) with an amplitude of ˜1012 A/m2, similar to all-metallic structures. We reveal that, in the presence of an initially nucleated domain, the critical switching current is reduced by up to a factor of five with respect to the fully saturated initial state, implying efficient current-driven domain wall motion in this system. Based on measurements with 2 ns-long pulses, we estimate the domain wall velocity of the order of ˜400 m/s per j = 1012 A/m2.

  11. Do axes of rotation change during fast and slow motions of the dominant and non-dominate arms?

    Directory of Open Access Journals (Sweden)

    Pagano Christopher

    2011-12-01

    Full Text Available The velocity-dependent change in rotational axes observed in the control of unconstrained 3D arm rotations for the dominant limb seems to conform to a minimum inertia resistance (MIR principle [4]. This is an efficient biomechanical solution that allows for the reduction of torques. We tested whether the MIR principle governs rotating movement when subjects were instructed to maintain the shoulder-elbow joint axis close to horizontal for both dominant and non dominant limbs. Subjects (n=12 performed externalinternal rotations of their arms in two angular positions (90° versus 150°, two angular velocities (slow (S versus fast (F, and in two sensory conditions (kinaesthetic (K versus visuo- kinaesthetic (VK. We expected more scattered displacements of the rotation axis employed for rotating the non dominant limb compared to the dominant limb. The results showed that the rotational axis of a multiarticulated limb coincided with SH-EL at S & F velocity for both arms.

  12. Electromechanical actuator with controllable motion, fast response rate, and high-frequency resonance based on graphene and polydiacetylene.

    Science.gov (United States)

    Liang, Jiajie; Huang, Lu; Li, Na; Huang, Yi; Wu, Yingpeng; Fang, Shaoli; Oh, Jiyoung; Kozlov, Mikhail; Ma, Yanfeng; Li, Feifei; Baughman, Ray; Chen, Yongsheng

    2012-05-22

    Although widely investigated, novel electromechanical actuators with high overall actuation performance are still in urgent need for various practical and scientific applications, such as robots, prosthetic devices, sensor switches, and sonar projectors. In this work, combining the properties of unique environmental perturbations-actuated deformational isomerization of polydiacetylene (PDA) and the outstanding intrinsic features of graphene together for the first time, we design and fabricate an electromechanical bimorph actuator composed of a layer of PDA crystal and a layer of flexible graphene paper through a simple yet versatile solution approach. Under low applied direct current (dc), the graphene-PDA bimorph actuator with strong mechanical strength can generate large actuation motion (curvature is about 0.37 cm(-1) under a current density of 0.74 A/mm(2)) and produce high actuation stress (more than 160 MPa/g under an applied dc of only 0.29 A/mm(2)). When applying alternating current (ac), this actuator can display reversible swing behavior with long cycle life under high frequencies even up to 200 Hz; significantly, while the frequency and the value of applied ac and the state of the actuators reach an appropriate value, the graphene-PDA actuator can produce a strong resonance and the swing amplitude will jump to a peak value. Moreover, this stable graphene-PDA actuator also demonstrates rapidly and partially reversible electrochromatic phenomenon when applying an ac. Two mechanisms-the dominant one, electric-induced deformation, and a secondary one, thermal-induced expansion of PDA-are proposed to contribute to these interesting actuation performances of the graphene-PDA actuators. On the basis of these results, a mini-robot with controllable direction of motion based on the graphene-PDA actuator is designed to illustrate the great potential of our discoveries for practical use. Combining the unique actuation mechanism and many outstanding properties of

  13. Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors

    International Nuclear Information System (INIS)

    Husstedt, H.W.; Sickert, M.; Koestler, H.; Haubitz, B.; Becker, H.

    2000-01-01

    The aim of this study was to quantify imaging characteristics of fast fluid-attenuated inversion recovery (FLAIR) sequence in brain tumors compared with T1-postcontrast- and T2-sequences. Fast-FLAIR-, T2 fast spin echo (FSE)-, and T1 SE postcontrast images of 74 patients with intracranial neoplasms were analyzed. Four neuroradiologists rated signal intensity and inhomogeneity of the tumor, rendering of cystic parts, demarcation of the tumor vs brain, of the tumor vs edema and of brain vs edema, as well as the presence of motion and of other artifacts. Data analysis was performed for histologically proven astrocytomas, glioblastomas, and meningiomas, for tumors with poor contrast enhancement, and for all patients pooled. Only for tumors with poor contrast enhancement (n = 12) did fast FLAIR provide additional information about the lesion. In these cases, signal intensity, demarcation of the tumor vs brain, and differentiation of the tumor vs edema were best using fast FLAIR. In all cases, rendering of the tumor's inner structure was poor. For all other tumor types, fast FLAIR did not give clinically relevant information, the only exception being a better demarcation of the edema from brain tissue. Artifacts rarely interfered with evaluation of fast-FLAIR images. Thus, fast FLAIR cannot replace T2-weighted series. It provides additional information only in tumors with poor contrast enhancement. It is helpful for defining the exact extent of the edema of any tumor but gives little information about their inner structure. (orig.)

  14. Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors.

    Science.gov (United States)

    Husstedt, H W; Sickert, M; Köstler, H; Haubitz, B; Becker, H

    2000-01-01

    The aim of this study was to quantify imaging characteristics of fast fluid-attenuated inversion recovery (FLAIR) sequence in brain tumors compared with T1-postcontrast- and T2-sequences. Fast-FLAIR-, T2 fast spin echo (FSE)-, and T1 SE postcontrast images of 74 patients with intracranial neoplasms were analyzed. Four neuroradiologists rated signal intensity and inhomogeneity of the tumor, rendering of cystic parts, demarcation of the tumor vs brain, of the tumor vs edema and of brain vs edema, as well as the presence of motion and of other artifacts. Data analysis was performed for histologically proven astrocytomas, glioblastomas, and meningiomas, for tumors with poor contrast enhancement, and for all patients pooled. Only for tumors with poor contrast enhancement (n = 12) did fast FLAIR provide additional information about the lesion. In these cases, signal intensity, demarcation of the tumor vs brain, and differentiation of the tumor vs edema were best using fast FLAIR. In all cases, rendering of the tumor's inner structure was poor. For all other tumor types, fast FLAIR did not give clinically relevant information, the only exception being a better demarcation of the edema from brain tissue. Artifacts rarely interfered with evaluation of fast-FLAIR images. Thus, fast FLAIR cannot replace T2-weighted series. It provides additional information only in tumors with poor contrast enhancement. It is helpful for defining the exact extent of the edema of any tumor but gives little information about their inner structure.

  15. Analysis of wave motion in one-dimensional structures through fast-Fourier-transform-based wavelet finite element method

    Science.gov (United States)

    Shen, Wei; Li, Dongsheng; Zhang, Shuaifang; Ou, Jinping

    2017-07-01

    This paper presents a hybrid method that combines the B-spline wavelet on the interval (BSWI) finite element method and spectral analysis based on fast Fourier transform (FFT) to study wave propagation in One-Dimensional (1D) structures. BSWI scaling functions are utilized to approximate the theoretical wave solution in the spatial domain and construct a high-accuracy dynamic stiffness matrix. Dynamic reduction on element level is applied to eliminate the interior degrees of freedom of BSWI elements and substantially reduce the size of the system matrix. The dynamic equations of the system are then transformed and solved in the frequency domain through FFT-based spectral analysis which is especially suitable for parallel computation. A comparative analysis of four different finite element methods is conducted to demonstrate the validity and efficiency of the proposed method when utilized in high-frequency wave problems. Other numerical examples are utilized to simulate the influence of crack and delamination on wave propagation in 1D rods and beams. Finally, the errors caused by FFT and their corresponding solutions are presented.

  16. Numerical Analysis on the Free Fall Motion of the Control Rod Assembly for the Sodium Cooled Fast Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Se-Hong; Choi, Choengryul; Son, Sung-Man [ELSOLTEC, Yongin (Korea, Republic of); Kim, Jae-Yong; Yoon, Kyung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    On receiving the scram signal, the control rod assemblies are released to fall into the reactor core by its weight. Thus drop time and falling velocity of the control rod assembly must be estimated for the safety evaluation. However, because of its complex shape, it is difficult to estimate the drop time by theoretical method. In this study, numerical analysis has been carried out in order to estimate drop time and falling velocity of the control rod assembly to provide the underlying data for the design optimization. Numerical analysis has been carried out to estimate the drop time and falling velocity of the control rod assembly for sodium-cooled fast reactor. Before performing the numerical analysis for the control rod assembly, sphere dropping experiment has been carried out for verification of the CFD methodology. The result of the numerical analysis for the method verification is almost same as the result of the experiment. Falling velocity and drag force increase rapidly in the beginning. And then it goes to the stable state. When the piston head of the control rod assembly is inserted into the damper, the drag force increases instantaneously and the falling velocity decreases quickly. The falling velocity is reduced about 14 % by damper. The total drop time of the control rod assembly is about 1.47s. In the next study, the experiment for the control rod assembly will be carried out, and its result is going to be compared with the CFD analysis result.

  17. Automated filtering of intrinsic movement artifacts during two-photon intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Denis Soulet

    Full Text Available In vivo imaging using two-photon microscopy is an essential tool to explore the dynamic of physiological events deep within biological tissues for short or extended periods of time. The new capabilities offered by this technology (e.g. high tissue penetrance, low toxicity have opened a whole new era of investigations in modern biomedical research. However, the potential of using this promising technique in tissues of living animals is greatly limited by the intrinsic irregular movements that are caused by cardiac and respiratory cycles and muscular and vascular tone. Here, we show real-time imaging of the brain, spinal cord, sciatic nerve and myenteric plexus of living mice using a new automated program, named Intravital_Microscopy_Toolbox, that removes frames corrupted with motion artifacts from time-lapse videos. Our approach involves generating a dissimilarity score against precalculated reference frames in a specific reference channel, thus allowing the gating of distorted, out-of-focus or translated frames. Since the algorithm detects the uneven peaks of image distortion caused by irregular animal movements, the macro allows a fast and efficient filtering of the image sequence. In addition, extra features have been implemented in the macro, such as XY registration, channel subtraction, extended field of view with maximum intensity projection, noise reduction with average intensity projections, and automated timestamp and scale bar overlay. Thus, the Intravital_Microscopy_Toolbox macro for ImageJ provides convenient tools for biologists who are performing in vivo two-photon imaging in tissues prone to motion artifacts.

  18. Fast lesion mapping during HIFU treatment using harmonic motion imaging guided focused ultrasound (HMIgFUS) in vitro and in vivo

    Science.gov (United States)

    Han, Yang; Wang, Shutao; Payen, Thomas; Konofagou, Elisa

    2017-04-01

    The successful clinical application of high intensity focused ultrasound (HIFU) ablation depends on reliable monitoring of the lesion formation. Harmonic motion imaging guided focused ultrasound (HMIgFUS) is an ultrasound-based elasticity imaging technique, which monitors HIFU ablation based on the stiffness change of the tissue instead of the echo intensity change in conventional B-mode monitoring, rendering it potentially more sensitive to lesion development. Our group has shown that predicting the lesion location based on the radiation force-excited region is feasible during HMIgFUS. In this study, the feasibility of a fast lesion mapping method is explored to directly monitor the lesion map during HIFU. The harmonic motion imaging (HMI) lesion map was generated by subtracting the reference HMI image from the present HMI peak-to-peak displacement map, as streamed on the computer display. The dimensions of the HMIgFUS lesions were compared against gross pathology. Excellent agreement was found between the lesion depth (r 2  =  0.81, slope  =  0.90), width (r 2  =  0.85, slope  =  1.12) and area (r 2  =  0.58, slope  =  0.75). In vivo feasibility was assessed in a mouse with a pancreatic tumor. These findings demonstrate that HMIgFUS can successfully map thermal lesions and monitor lesion development in real time in vitro and in vivo. The HMIgFUS technique may therefore constitute a novel clinical tool for HIFU treatment monitoring.

  19. Checking behavioral conformance of artifacts

    NARCIS (Netherlands)

    Fahland, D.; Leoni, de M.; Dongen, van B.F.; Aalst, van der W.M.P.

    2011-01-01

    The usefulness of process models (e.g., for analysis, improvement, or execution) strongly depends on their ability to describe reality. Conformance checking is a technique to validate how good a given process model describes recorded executions of the actual process. Recently, artifacts have been

  20. Toddlers View Artifact Function Normatively

    Science.gov (United States)

    Casler, Krista; Terziyan, Treysi; Greene, Kimberly

    2009-01-01

    When children use objects like adults, are they simply tracking regularities in others' object use, or are they demonstrating a normatively defined awareness that there are right and wrong ways to act? This study provides the first evidence for the latter possibility. Young 2- and 3-year-olds (n = 32) learned functions of 6 artifacts, both…

  1. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    Directory of Open Access Journals (Sweden)

    Paolo Domenici

    2014-12-01

    Full Text Available Fast-starts are brief accelerations commonly observed in fish within the context of predator–prey interactions. In typical C-start escape responses, fish react to a threatening stimulus by bending their body into a C-shape during the first muscle contraction (i.e. stage 1 which provides a sudden acceleration away from the stimulus. Recently, similar C-starts have been recorded in fish aiming at a prey. Little is known about C-starts outside the context of predator–prey interactions, though recent work has shown that escape response can also be induced by high temperature. Here, we test the hypothesis that air-breathing fish may use C-starts in the context of gulping air at the surface. Hoplosternum littorale is an air-breathing freshwater catfish found in South America. Field video observations reveal that their air-breathing behaviour consists of air-gulping at the surface, followed by a fast turn which re-directs the fish towards the bottom. Using high-speed video in the laboratory, we compared the kinematics of the turn immediately following air-gulping performed by H. littorale in normoxia with those of mechanically-triggered C-start escape responses and with routine (i.e. spontaneous turns. Our results show that air-breathing events overlap considerably with escape responses with a large stage 1 angle in terms of turning rates, distance covered and the relationship between these rates. Therefore, these two behaviours can be considered kinematically comparable, suggesting that air-breathing in this species is followed by escape-like C-start motions, presumably to minimise time at the surface and exposure to avian predators. These findings show that C-starts can occur in a variety of contexts in which fish may need to get away from areas of potential danger.

  2. Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs

    International Nuclear Information System (INIS)

    Slagmolen, Pieter; Hermans, Jeroen; Maes, Frederik; Budiharto, Tom; Haustermans, Karin; Heuvel, Frank van den

    2010-01-01

    takes a little less than a second where most time is spent on the image preprocessing. Conclusions: The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.

  3. Artifacts as Authoritative Actors in Educational Reform

    Science.gov (United States)

    März, Virginie; Kelchtermans, Geert; Vermeir, Karen

    2017-01-01

    Educational reforms are often translated in and implemented through artifacts. Although research has frequently treated artifacts as merely functional, more recent work acknowledges the complex relationship between material artifacts and human/organizational behavior. This article aims at disentangling this relationship in order to deepen our…

  4. Artifact

    DEFF Research Database (Denmark)

    2014-01-01

    CONCEPTUAL TYPE: TYPE LED BY IDEAS 26/10/12“Where are the idealistic fonts, the artsy fonts, the non fonts, the political fonts, the funny fonts, the difficult fonts, the fonts that don’t look like fonts, the fonts that are frontiers of new beliefs? We would like to focus on the ideas and concept...

  5. Artifacts in MR angiography of the intracranial vessels using the 3D TOF and 3D PC techniques

    International Nuclear Information System (INIS)

    Park, Dong Woo; Lee, Seung Ro; Hahm, Chang Kok; Kim, Yong Soo; Park, Choong Ki

    1997-01-01

    To classify artifacts and to assess their frequency in magnetic resonance angiography of intracranial vessels using three- dimensional time-of-flight and phase-contrast techniques. One hundred and eleven patients with suspected cerebrovascular disease were imaged on a 1.5T superconducting magnetic resonance machine employing three- dimensional time-of-flight and phase-contrast magnetic resonance angiographic techniques. We retrospectively reviewed the artifacts in three- dimensional time-of-flight and phase-contrast magnetic resonance angiography of the intracranial circulatory system, comparing them with routine spin-echo magnetic resonance images and magnetic resonance angiography source images, and partially with conventional angiography. Artifacts in magnetic resonance angiography were classified as flow-related, and flow-unrealted, by patient, hardware, magnetic resonance angiography acquisition and postprocessing techniques. Type and frequency of flow-related artifacts included saturation artifact (100%), dephasing artifact (100%), phase-encoding ghost artifact (97%), turbulence artifact (14%) and flow displacement artifact (5%) on three- dimensional time-of-flight and phase-contrast magnetic resonance angiography, and phase aliasing artifact (2%) on three-dimensional phase-contrast magnetic resonance angiography. Type and frequency of flow-unrelated artifacts included stair-step artifact (100%) by three- dimensional reconstruction process, magnetic susceptibility artifact by carotid canal (69%) and metal (4%), maximum intensity projection artifact (30%) by maximum intensity projection algorithm, and motion artifact by respiration (20%) and voluntary movement (8%); these were seen on both time-of-flight and phase-contrast magnetic resonance angiography. Paramagnetic substance artifact by fat and paranasal sinus mucosa (100%), hematoma (14%) and gadolinium (5%) were seen on time-of-flight magnetic resonance angiography. In three- dimensional time-of-flight and

  6. Reducing 4D CT artifacts using optimized sorting based on anatomic similarity.

    Science.gov (United States)

    Johnston, Eric; Diehn, Maximilian; Murphy, James D; Loo, Billy W; Maxim, Peter G

    2011-05-01

    Four-dimensional (4D) computed tomography (CT) has been widely used as a tool to characterize respiratory motion in radiotherapy. The two most commonly used 4D CT algorithms sort images by the associated respiratory phase or displacement into a predefined number of bins, and are prone to image artifacts at transitions between bed positions. The purpose of this work is to demonstrate a method of reducing motion artifacts in 4D CT by incorporating anatomic similarity into phase or displacement based sorting protocols. Ten patient datasets were retrospectively sorted using both the displacement and phase based sorting algorithms. Conventional sorting methods allow selection of only the nearest-neighbor image in time or displacement within each bin. In our method, for each bed position either the displacement or the phase defines the center of a bin range about which several candidate images are selected. The two dimensional correlation coefficients between slices bordering the interface between adjacent couch positions are then calculated for all candidate pairings. Two slices have a high correlation if they are anatomically similar. Candidates from each bin are then selected to maximize the slice correlation over the entire data set using the Dijkstra's shortest path algorithm. To assess the reduction of artifacts, two thoracic radiation oncologists independently compared the resorted 4D datasets pairwise with conventionally sorted datasets, blinded to the sorting method, to choose which had the least motion artifacts. Agreement between reviewers was evaluated using the weighted kappa score. Anatomically based image selection resulted in 4D CT datasets with significantly reduced motion artifacts with both displacement (P = 0.0063) and phase sorting (P = 0.00022). There was good agreement between the two reviewers, with complete agreement 34 times and complete disagreement 6 times. Optimized sorting using anatomic similarity significantly reduces 4D CT motion

  7. Use of cognitive artifacts in chemistry learning

    Science.gov (United States)

    Yengin, Ilker

    In everyday life, we interact with cognitive artifacts to receive and/or manipulate information so as to alter our thinking processes. CHEM/TEAC 869Q is a distance course that includes extensive explicit instruction in the use of a cognitive artifact. This study investigates issues related to the design of that online artifact. In order to understand design implications and how cognitive artifacts contribute to students' thinking and learning, a qualitative research methodology was engaged that utilized think aloud sessions. Participants' described constrained and structured cognitive models while using the artifact. The study also was informed by interviews and researcher's field notes. A purposeful sampling method led to the selection of participants, four males and two females, who had no prior history of using a course from the 869 series but who had experienced the scientific content covered by the CHEM869Q course. Analysis of the results showed both that a cognitive artifact may lead users' minds in decision making, and that problem solving processes were affected by cognitive artifact's design. When there is no design flaw, users generally thought that the cognitive artifact was helpful by simplifying steps, overcoming other limitations, and reducing errors in a reliable, effective, and easy to use way. Moreover, results showed that successful implementation of cognitive artifacts into teaching --learning practices depended on user willingness to transfer a task to the artifact. While users may like the idea of benefiting from a cognitive artifact, nevertheless, they may tend to limit their usage. They sometimes think that delegating a task to a cognitive artifact makes them dependent, and that they may not learn how to perform the tasks by themselves. They appear more willing to use a cognitive artifact after they have done the task by themselves.

  8. Designing a compact MRI motion phantom

    Directory of Open Access Journals (Sweden)

    Schmiedel Max

    2016-09-01

    Full Text Available Even today, dealing with motion artifacts in magnetic resonance imaging (MRI is a challenging task. Image corruption due to spontaneous body motion complicates diagnosis. In this work, an MRI phantom for rigid motion is presented. It is used to generate motion-corrupted data, which can serve for evaluation of blind motion compensation algorithms. In contrast to commercially available MRI motion phantoms, the presented setup works on small animal MRI systems. Furthermore, retrospective gating is performed on the data, which can be used as a reference for novel motion compensation approaches. The motion of the signal source can be reconstructed using motor trigger signals and be utilized as the ground truth for motion estimation. The proposed setup results in motion corrected images. Moreover, the importance of preprocessing the MRI raw data, e.g. phase-drift correction, is demonstrated. The gained knowledge can be used to design an MRI phantom for elastic motion.

  9. MADR: metal artifact detection and reduction

    Science.gov (United States)

    Jaiswal, Sunil Prasad; Ha, Sungsoo; Mueller, Klaus

    2016-04-01

    Metal in CT-imaged objects drastically reduces the quality of these images due to the severe artifacts it can cause. Most metal artifacts reduction (MAR) algorithms consider the metal-affected sinogram portions as the corrupted data and replace them via sophisticated interpolation methods. While these schemes are successful in removing the metal artifacts, they fail to recover some of the edge information. To address these problems, the frequency shift metal artifact reduction algorithm (FSMAR) was recently proposed. It exploits the information hidden in the uncorrected image and combines the high frequency (edge) components of the uncorrected image with the low frequency components of the corrected image. Although this can effectively transfer the edge information of the uncorrected image, it also introduces some unwanted artifacts. The essential problem of these algorithms is that they lack the capability of detecting the artifacts and as a result cannot discriminate between desired and undesired edges. We propose a scheme that does better in these respects. Our Metal Artifact Detection and Reduction (MADR) scheme constructs a weight map which stores whether a pixel in the uncorrected image belongs to an artifact region or a non-artifact region. This weight matrix is optimal in the Linear Minimum Mean Square Sense (LMMSE). Our results demonstrate that MADR outperforms the existing algorithms and ensures that the anatomical structures close to metal implants are better preserved.

  10. Detection of movement artifact in recorded pulse oximeter saturation.

    Science.gov (United States)

    Poets, C F; Stebbens, V A

    1997-10-01

    Movement artifact (MA) must be detected when analysing recordings of pulse oximeter saturation (SpO2). Visual analysis of individual pulse waveforms is the safest, but also the most tedious, method for this purpose. We wanted to test the reliability of a computer algorithm (Edentec Motion Annotation System), based on a comparison between pulse and heart rate, for MA detection. Ten 12-h recordings of SpO2, pulse waveforms and heart rate from ten preterm infants were analysed for the presence of MA on the pulse waveform signal. These data were used to determine the sensitivity and specificity of the computer algorithm, and of the oximeter itself, in detecting MA. Recordings were divided into segments of 2.5 s duration to compare the movement identification methods. Of the segments 31% +/- 6% (mean +/- SD) contained MA. The computer algorithm identified 95% +/- 3% of these segments, the pulse oximeter only 18% +/- 11%. Specificity was 85% +/- 4% and 99% +/- 0%, respectively. SpO2 was signal showed MA during this time, leaving a significant potential for erroneous identification of hypoxaemia. Recordings of SpO2 do not allow a reliable identification of MA. Without additional information about movement artifact, a significant proportion of recording time of pulse oximeter signal may be regarded as demonstrating hypoxaemia which, in fact, simply reflects poor measurement conditions. The computer algorithm used in this study identified periods of movement artifact reliably.

  11. Independent component analysis of gait-related movement artifact recorded using EEG electrodes during treadmill walking.

    Directory of Open Access Journals (Sweden)

    Kristine Lynne Snyder

    2015-12-01

    Full Text Available There has been a recent surge in the use of electroencephalography (EEG as a tool for mobile brain imaging due to its portability and fine time resolution. When EEG is combined with independent component analysis (ICA and source localization techniques, it can model electrocortical activity as arising from temporally independent signals located in spatially distinct cortical areas. However, for mobile tasks, it is not clear how movement artifacts influence ICA and source localization. We devised a novel method to collect pure movement artifact data (devoid of any electrophysiological signals with a 256-channel EEG system. We first blocked true electrocortical activity using a silicone swim cap. Over the silicone layer, we placed a simulated scalp with electrical properties similar to real human scalp. We collected EEG movement artifact signals from ten healthy, young subjects wearing this setup as they walked on a treadmill at speeds from 0.4-1.6 m/s. We performed ICA and dipole fitting on the EEG movement artifact data to quantify how accurately these methods would identify the artifact signals as non-neural. ICA and dipole fitting accurately localized 99% of the independent components in non-neural locations or lacked dipolar characteristics. The remaining 1% of sources had locations within the brain volume and low residual variances, but had topographical maps, power spectra, time courses, and event related spectral perturbations typical of non-neural sources. Caution should be exercised when interpreting ICA for data that includes semi-periodic artifacts including artifact arising from human walking. Alternative methods are needed for the identification and separation of movement artifact in mobile EEG signals, especially methods that can be performed in real time. Separating true brain signals from motion artifact could clear the way for EEG brain computer interfaces for assistance during mobile activities, such as walking.

  12. A particle accelerator probes artifacts

    International Nuclear Information System (INIS)

    Dran, J.C.; Calligaro, Th.; Salomon, J.

    2002-01-01

    The AGLAE system is made up of a 2 mega volts electrostatic accelerator and of 3 irradiation lines: one leads to a vacuum enclosure in which targets are irradiated and the 2 others lines are designed to irradiate targets under an air or helium atmosphere. The AGLAE system is located in the premises of the Louvre museum in Paris and is devoted to the study of cultural objects through ion beam analysis (IBA). 4 techniques are used: -) proton-induced X-ray emission (PIXE) -) proton-induced gamma ray (PIGE) -) Rutherford backscattering spectrometry (NRS) and -) nuclear reaction analysis (NRA). A decisive progress has permitted the direct analysis of artifacts without sampling. The object itself is set just a few millimeters away from the exit window of the beam in an air or helium atmosphere. The exit window must be resistant enough to bear the atmospheric pressure and the damages caused by the proton beam but must be thin enough to not deteriorate the quality of the beam. By using a 10 -7 m thick exit window made of Si 3 N 4 we get a beam whose diameter is 10 -5 m. This new technology presents 4 main advantages: 1) any object of any shape can be studied without sampling, 2) the analysis of very fragile artifacts that might be damaged by the vacuum setting is now possible, 3) a reduction of the thermal side-effects of the beam, and 4) the absence of accumulation of charges in isolating material allows to rid of covering the object with a conducting coating before irradiating it. (A.C.)

  13. The Many Faces of Computational Artifacts

    DEFF Research Database (Denmark)

    Christensen, Lars Rune; Harper, Richard

    2016-01-01

    Building on data from fieldwork at a medical department, this paper focuses on the varied nature of computational artifacts in practice. It shows that medical practice relies on multiple heterogeneous computational artifacts that form complex constellations. In the hospital studied the computatio...

  14. Reducing artifacts from varying projection truncations

    DEFF Research Database (Denmark)

    Borg, Leise; Jørgensen, Jakob Sauer; Frikel, Jürgen

    We study samples with full and partial occlusion causing streak artifacts, and propose two modifications of filtered backprojection for artifact removal. Data is obtained by the SPring-8 synchrotron using a monochromatic parallel-beam scan [1]. Thresholding in the sinogram segments the metal...

  15. Conceptual Model of Artifacts for Design Science Research

    DEFF Research Database (Denmark)

    Bækgaard, Lars

    2015-01-01

    We present a conceptual model of design science research artifacts. The model views an artifact at three levels. At the artifact level a selected artifact is viewed as a combination of material and immaterial aspects and a set of representations hereof. At the design level the selected artifact...

  16. Technical Assessment of Artifact Production from Neuro Endovascular Coil At 3 Tesla MRI: An In Vitro Study

    International Nuclear Information System (INIS)

    Kampaengtip, A.; Krisanachinda, A.; Singhara Na Ayudya, S.; Asavaphatiboon, S.

    2012-01-01

    Introduction: Magnetic resonance imaging (MRI) is an essential part of the diagnostic procedures in radiology. MRI 3 Tesla becomes more widespread due to high signal to noise ratio (SNR). The use of the neuro endovascular coil to overcome the neuro aneurysm can introduce the artifact in magnetic resonance imaging. Susceptibility artifacts and geometric distortions caused by magnetic field inhomogeneity- related signal loss is used to refer to an artifact in magnetic resonance images. It consists of a region of signal void with a surrounding area of an increased signal intensity that appears to be considerably larger than the actual size of the device causing the artifact. The objective of the study is to compare the size of the artifact on the MR image to the actual size of endovascular coils using a 3 Tesla magnetic resonance imaging system, in vitro study. Methods: The endovascular coils were made from detachable platinum and aneurysm models were constructed by using silicone tube. MRI 3 Tesla Philips Model Achieva with pulse sequence selections were: spin echo, fast spin echo, inversion recovery, fast gradient echo while additional parameters were echo time and turbo factor. Results: Improved visualization of perianeurysmal soft tissues is best accomplished by spin echo for fast spin echo sequences, even better suited to reduce metal artifact. Furthermore, shorter turbo factor and shorter effective TE in the latter sequences are beneficial for the same reason as sequences having shorter TE. Sequences with a shorter TE are preferred because of less time for dephasing and frequency shifting. Imaging at gradient echo series increases susceptibility artifacts. In this in vitro study, some of the major characteristics related to MRI imaging of coil packs have been defined. Discussion: Pulse sequence spin echo is the best sequence reducing the susceptibility artifact. Reducing the TE is the main factor in improving endovascular coil visualization on MRI images. The

  17. Image artifacts and technical limitations

    International Nuclear Information System (INIS)

    Kelly, W.M.

    1987-01-01

    The swift temporal progression of magnetic resonance imaging (MRI) from experimental prototype design to sophisticated instrument production can be sharply contrasted to the more protracted time course that characterized the development of X-ray computed tomography (CT). Most notably, the current generation of CT scanners represents the product of more than a decade of design innovation and technologic improvement, punctuated by the introduction of a whole new ''generation'' of CT scanners at periodic intervals. The more rapid evolutionary changes unique to MRI have been permitted by the greater abundance of sophisticated technologic expertise and necessitated by economic considerations, especially the desire to avoid premature obsolescence. Quite clearly, ''state-of-the-art'' MRI units available today are intended to remain state of the art for many years into the future. In clinical trials, MRI has proved particularly effacacious for evaluation of suspected neurologic disease, prompting neuroradiologists to welcome this new non-invasive diagnostic tool with unprecedented enthusiasm. In early reports, the lack of ionizing radiation, apparent absence of significant biological hazards, and ''elimination'' of artifacts were all acclaimed as major technical advantages. Now, as this diagnostic modality is undergoing widespread dissemination and a large body of clinical experience begins to accumulate, increasing attention is being focused on the limitations of MRI

  18. A particle accelerator probes artifacts

    CERN Document Server

    Dran, J C; Salomon, J

    2002-01-01

    The AGLAE system is made up of a 2 mega volts electrostatic accelerator and of 3 irradiation lines: one leads to a vacuum enclosure in which targets are irradiated and the 2 others lines are designed to irradiate targets under an air or helium atmosphere. The AGLAE system is located in the premises of the Louvre museum in Paris and is devoted to the study of cultural objects through ion beam analysis (IBA). 4 techniques are used: -) proton-induced X-ray emission (PIXE) -) proton-induced gamma ray (PIGE) -) Rutherford backscattering spectrometry (NRS) and -) nuclear reaction analysis (NRA). A decisive progress has permitted the direct analysis of artifacts without sampling. The object itself is set just a few millimeters away from the exit window of the beam in an air or helium atmosphere. The exit window must be resistant enough to bear the atmospheric pressure and the damages caused by the proton beam but must be thin enough to not deteriorate the quality of the beam. By using a 10 sup - sup 7 m thick exit w...

  19. Material-Dependent Implant Artifact Reduction Using SEMAC-VAT and MAVRIC: A Prospective MRI Phantom Study.

    Science.gov (United States)

    Filli, Lukas; Jud, Lukas; Luechinger, Roger; Nanz, Daniel; Andreisek, Gustav; Runge, Val M; Kozerke, Sebastian; Farshad-Amacker, Nadja A

    2017-06-01

    The aim of this study was to compare the degree of artifact reduction in magnetic resonance imaging achieved with slice encoding for metal artifact correction (SEMAC) in combination with view angle tilting (VAT) and multiacquisition variable resonance image combination (MAVRIC) for standard contrast weightings and different metallic materials. Four identically shaped rods made of the most commonly used prosthetic materials (stainless steel, SS; titanium, Ti; cobalt-chromium-molybdenum, CoCr; and oxidized zirconium, oxZi) were scanned at 3 T. In addition to conventional fast spin-echo sequences, metal artifact reduction sequences (SEMAC-VAT and MAVRIC) with varying degrees of artifact suppression were applied at different contrast weightings (T1w, T2w, PDw). Two independent readers measured in-plane and through-plane artifacts in a standardized manner. In addition, theoretical frequency-offset and frequency-offset-gradient maps were calculated. Interobserver agreement was assessed using intraclass correlation coefficient. Interobserver agreement was almost perfect (intraclass correlation coefficient, 0.86-0.99). Stainless steel caused the greatest artifacts, followed by CoCr, Ti, and oxZi regardless of the imaging sequence. While for Ti and oxZi rods scanning with weak SEMAC-VAT showed some advantage, for SS and CoCr, higher modes of SEMAC-VAT or MAVRIC were necessary to achieve artifact reduction. MAVRIC achieved better artifact reduction than SEMAC-VAT at the cost of longer acquisition times. Simulations matched well with the apparent geometry of the frequency-offset maps. For Ti and oxZi implants, weak SEMAC-VAT may be preferred as it is faster and produces less artifact than conventional fast spin-echo. Medium or strong SEMAC-VAT or MAVRIC modes are necessary for significant artifact reduction for SS and CoCr implants.

  20. Constant flow ventilation as a novel approach to elimination of respiratory artifact in MR imaging

    International Nuclear Information System (INIS)

    Shtern, F.; Kersh, R.; Lee, A.; Venegas, J.; Brady, T.J.

    1988-01-01

    This pilot study was performed to evaluate constant flow ventilation (CFV) as a method of respiratory artifact suppression in magnetic resonance (MR) imaging. In contrast to currently used methods of respiratory artifact suppression, CFV is able to provide adequate ventilation in the absence of any chest wall motion and thus obviates the need for respiratory gating. High-velocity jets of fresh gas delivered through two narrow (2-mm) intrabronchial cannulas promote gas exchange through airway turbulence and enhanced molecular diffusion. One mongrel dog (8.5 kg) was anesthetized with pentobarbital (35 mg/kg). For CFV, endobronchial cannulas were inserted with the aid of bronchoscopy and connected to a flow meter (flow rate, 500 mL/sec). Intrathoracic pressure was monitored via a pressure transducer connected to an air-filled intraesophageal balloon. Conventional ventilation (CV), with a tidal volume of 85 mL and ten breaths per minute, was provided through a cuffed endotracheal tube. After establishment of adequate ventilation (carbon dioxide pressure, 39), muscle paralysis was induced by succinylcholine at 0.1 mg/kg. T2-weighted [1,500/50 (repetition time msec/echo time msec), two excitations] gradient-echo and spin-echo images were obtained at 0.6T with both CV and CFV. MR images with CFV were free of respiratory motion artifact, which was present on all MR images with CV. This pilot study indicates that implementation of CFV results in elimination of respiratory motion artifact

  1. Iterative Covariance-Based Removal of Time-Synchronous Artifacts: Application to Gastrointestinal Electrical Recordings.

    Science.gov (United States)

    Erickson, Jonathan C; Putney, Joy; Hilbert, Douglas; Paskaranandavadivel, Niranchan; Cheng, Leo K; O'Grady, Greg; Angeli, Timothy R

    2016-11-01

    The aim of this study was to develop, validate, and apply a fully automated method for reducing large temporally synchronous artifacts present in electrical recordings made from the gastrointestinal (GI) serosa, which are problematic for properly assessing slow wave dynamics. Such artifacts routinely arise in experimental and clinical settings from motion, switching behavior of medical instruments, or electrode array manipulation. A novel iterative Covariance-Based Reduction of Artifacts (COBRA) algorithm sequentially reduced artifact waveforms using an updating across-channel median as a noise template, scaled and subtracted from each channel based on their covariance. Application of COBRA substantially increased the signal-to-artifact ratio (12.8 ± 2.5 dB), while minimally attenuating the energy of the underlying source signal by 7.9% on average ( -11.1 ± 3.9 dB). COBRA was shown to be highly effective for aiding recovery and accurate marking of slow wave events (sensitivity = 0.90 ± 0.04; positive-predictive value = 0.74 ± 0.08) from large segments of in vivo porcine GI electrical mapping data that would otherwise be lost due to a broad range of contaminating artifact waveforms. Strongly reducing artifacts with COBRA ultimately allowed for rapid production of accurate isochronal activation maps detailing the dynamics of slow wave propagation in the porcine intestine. Such mapping studies can help characterize differences between normal and dysrhythmic events, which have been associated with GI abnormalities, such as intestinal ischemia and gastroparesis. The COBRA method may be generally applicable for removing temporally synchronous artifacts in other biosignal processing domains.

  2. SU-F-303-17: Real Time Dose Calculation of MRI Guided Co-60 Radiotherapy Treatments On Free Breathing Patients, Using a Motion Model and Fast Monte Carlo Dose Calculation

    International Nuclear Information System (INIS)

    Thomas, D; O’Connell, D; Lamb, J; Cao, M; Yang, Y; Agazaryan, N; Lee, P; Low, D

    2015-01-01

    Purpose: To demonstrate real-time dose calculation of free-breathing MRI guided Co−60 treatments, using a motion model and Monte-Carlo dose calculation to accurately account for the interplay between irregular breathing motion and an IMRT delivery. Methods: ViewRay Co-60 dose distributions were optimized on ITVs contoured from free-breathing CT images of lung cancer patients. Each treatment plan was separated into 0.25s segments, accounting for the MLC positions and beam angles at each time point. A voxel-specific motion model derived from multiple fast-helical free-breathing CTs and deformable registration was calculated for each patient. 3D images for every 0.25s of a simulated treatment were generated in real time, here using a bellows signal as a surrogate to accurately account for breathing irregularities. Monte-Carlo dose calculation was performed every 0.25s of the treatment, with the number of histories in each calculation scaled to give an overall 1% statistical uncertainty. Each dose calculation was deformed back to the reference image using the motion model and accumulated. The static and real-time dose calculations were compared. Results: Image generation was performed in real time at 4 frames per second (GPU). Monte-Carlo dose calculation was performed at approximately 1frame per second (CPU), giving a total calculation time of approximately 30 minutes per treatment. Results show both cold- and hot-spots in and around the ITV, and increased dose to contralateral lung as the tumor moves in and out of the beam during treatment. Conclusion: An accurate motion model combined with a fast Monte-Carlo dose calculation allows almost real-time dose calculation of a free-breathing treatment. When combined with sagittal 2D-cine-mode MRI during treatment to update the motion model in real time, this will allow the true delivered dose of a treatment to be calculated, providing a useful tool for adaptive planning and assessing the effectiveness of gated treatments

  3. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.

    Science.gov (United States)

    den Harder, J Chiel; van Yperen, Gert H; Blume, Ulrike A; Bos, Clemens

    2015-01-01

    Multispectral imaging (MSI) significantly reduces metal artifacts. Yet, especially in techniques that use gradient selection, such as slice encoding for metal artifact correction (SEMAC), a residual ripple artifact may be prominent. Here, an analysis is presented of the ripple artifact and of slice overlap as an approach to reduce the artifact. The ripple artifact was analyzed theoretically to clarify its cause. Slice overlap, conceptually similar to spectral bin overlap in multi-acquisition with variable resonances image combination (MAVRIC), was achieved by reducing the selection gradient and, thus, increasing the slice profile width. Time domain simulations and phantom experiments were performed to validate the analyses and proposed solution. Discontinuities between slices are aggravated by signal displacement in the frequency encoding direction in areas with deviating B0. Specifically, it was demonstrated that ripple artifacts appear only where B0 varies both in-plane and through-plane. Simulations and phantom studies of metal implants confirmed the efficacy of slice overlap to reduce the artifact. The ripple artifact is an important limitation of gradient selection based MSI techniques, and can be understood using the presented simulations. At a scan-time penalty, slice overlap effectively addressed the artifact, thereby improving image quality near metal implants. © 2014 Wiley Periodicals, Inc.

  4. Motion of the esophagus due to cardiac motion.

    Directory of Open Access Journals (Sweden)

    Jacob Palmer

    Full Text Available When imaging studies (e.g. CT are used to quantify morphological changes in an anatomical structure, it is necessary to understand the extent and source of motion which can give imaging artifacts (e.g. blurring or local distortion. The objective of this study was to assess the magnitude of esophageal motion due to cardiac motion. We used retrospective electrocardiogram-gated contrast-enhanced computed tomography angiography images for this study. The anatomic region from the carina to the bottom of the heart was taken at deep-inspiration breath hold with the patients' arms raised above their shoulders, in a position similar to that used for radiation therapy. The esophagus was delineated on the diastolic phase of cardiac motion, and deformable registration was used to sequentially deform the images in nearest-neighbor phases among the 10 cardiac phases, starting from the diastolic phase. Using the 10 deformation fields generated from the deformable registration, the magnitude of the extreme displacements was then calculated for each voxel, and the mean and maximum displacement was calculated for each computed tomography slice for each patient. The average maximum esophageal displacement due to cardiac motion for all patients was 5.8 mm (standard deviation: 1.6 mm, maximum: 10.0 mm in the transverse direction. For 21 of 26 patients, the largest esophageal motion was found in the inferior region of the heart; for the other patients, esophageal motion was approximately independent of superior-inferior position. The esophagus motion was larger at cardiac phases where the electrocardiogram R-wave occurs. In conclusion, the magnitude of esophageal motion near the heart due to cardiac motion is similar to that due to other sources of motion, including respiratory motion and intra-fraction motion. A larger cardiac motion will result into larger esophagus motion in a cardiac cycle.

  5. Evaluating an artifact in design science research

    CSIR Research Space (South Africa)

    Herselman, M

    2015-09-01

    Full Text Available In this paper, we describe the iterative evaluation of an artifact developed through the application of Design Science Research (DSR) methodology in a resource constrained environment. In the DSR process the aspect of evaluation is often done...

  6. Online Artifact Removal for Brain-Computer Interfaces Using Support Vector Machines and Blind Source Separation

    Directory of Open Access Journals (Sweden)

    Sebastian Halder

    2007-01-01

    that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA and one BSS algorithm (AMUSE are evaluated to determine their ability to isolate electromyographic (EMG and electrooculographic (EOG artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method.

  7. Infrared and Raman study of the fast internal motions of non-rigid molecules in condensed state: method of selective deuteration

    International Nuclear Information System (INIS)

    Lascombe, J.; Cavagnat, D.; Lassegues, J.C.; Rafilipomanana, C.

    1983-01-01

    The dynamical behaviour of non-rigid molecules in the gas state is now well known but very little information is available on these molecules in condensed state. The authors present a method of study based on the analysis of the infrared and Raman spectra of selectively deuterated molecules. It is applied to the nitromethane and cyclopentene molecules which provide respectively characteristic examples of methyl internal rotation and ring-puckering motion. In each case, an isolated -C0 or -CD oscillator is modulated by the internal motion and several γ(CH) or γ(CD) bands are observed as a result of the dependence of the vibrational frequency of the oscillator on its conformational situation. Moreover, in the case of crystalline nitromethane a detailed study of the temperature dependence of the band profiles allows the main mechanism of relaxation of the -CH oscillator to be deduced. (orig.)

  8. Short echo time, fast gradient-echo imaging

    International Nuclear Information System (INIS)

    Haacke, E.M.; Lenz, G.W.

    1987-01-01

    Present fast-gradient-echoes schemes can acquire volume data rapidly and are flexible in T1 or T1/T2 contrast behavior. However, sequences used to date employ echo time (TE) values of about 15 ms +- 5 and, because of in vivo field inhomogeneities (short T2), they suffer badly from signal loss near sinuses and tissue boundaries. The authors implemented sequences with TE = 4-6 ms and found significant improvement in image quality, especially at high fields. Examples with long TEs vs. short TEs are given in the knee, spine, head, and orbits. Further advantages include (1) faster repetition times (15 ms), (2) higher-quality spin-density or T1-weighted images, and (3) reduction of blood motion artifacts

  9. Audiovisual biofeedback improves diaphragm motion reproducibility in MRI

    Science.gov (United States)

    Kim, Taeho; Pollock, Sean; Lee, Danny; O’Brien, Ricky; Keall, Paul

    2012-01-01

    Purpose: In lung radiotherapy, variations in cycle-to-cycle breathing results in four-dimensional computed tomography imaging artifacts, leading to inaccurate beam coverage and tumor targeting. In previous studies, the effect of audiovisual (AV) biofeedback on the external respiratory signal reproducibility has been investigated but the internal anatomy motion has not been fully studied. The aim of this study is to test the hypothesis that AV biofeedback improves diaphragm motion reproducibility of internal anatomy using magnetic resonance imaging (MRI). Methods: To test the hypothesis 15 healthy human subjects were enrolled in an ethics-approved AV biofeedback study consisting of two imaging sessions spaced ∼1 week apart. Within each session MR images were acquired under free breathing and AV biofeedback conditions. The respiratory signal to the AV biofeedback system utilized optical monitoring of an external marker placed on the abdomen. Synchronously, serial thoracic 2D MR images were obtained to measure the diaphragm motion using a fast gradient-recalled-echo MR pulse sequence in both coronal and sagittal planes. The improvement in the diaphragm motion reproducibility using the AV biofeedback system was quantified by comparing cycle-to-cycle variability in displacement, respiratory period, and baseline drift. Additionally, the variation in improvement between the two sessions was also quantified. Results: The average root mean square error (RMSE) of diaphragm cycle-to-cycle displacement was reduced from 2.6 mm with free breathing to 1.6 mm (38% reduction) with the implementation of AV biofeedback (p-value biofeedback (p-value biofeedback (p-value = 0.012). The diaphragm motion reproducibility improvements with AV biofeedback were consistent with the abdominal motion reproducibility that was observed from the external marker motion variation. Conclusions: This study was the first to investigate the potential of AV biofeedback to improve the motion

  10. Blind retrospective motion correction of MR images.

    Science.gov (United States)

    Loktyushin, Alexander; Nickisch, Hannes; Pohmann, Rolf; Schölkopf, Bernhard

    2013-12-01

    Subject motion can severely degrade MR images. A retrospective motion correction algorithm, Gradient-based motion correction, which significantly reduces ghosting and blurring artifacts due to subject motion was proposed. The technique uses the raw data of standard imaging sequences; no sequence modifications or additional equipment such as tracking devices are required. Rigid motion is assumed. The approach iteratively searches for the motion trajectory yielding the sharpest image as measured by the entropy of spatial gradients. The vast space of motion parameters is efficiently explored by gradient-based optimization with a convergence guarantee. The method has been evaluated on both synthetic and real data in two and three dimensions using standard imaging techniques. MR images are consistently improved over different kinds of motion trajectories. Using a graphics processing unit implementation, computation times are in the order of a few minutes for a full three-dimensional volume. The presented technique can be an alternative or a complement to prospective motion correction methods and is able to improve images with strong motion artifacts from standard imaging sequences without requiring additional data. Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

  11. Capillary Electrophoresis Artifact Due to Eosin

    Science.gov (United States)

    Murphy, Kathleen M.; Berg, Karin D.; Geiger, Tanya; Hafez, Michael; Flickinger, Katie A.; Cooper, Lisa; Pearson, Patrick; Eshleman, James R.

    2005-01-01

    Capillary electrophoresis (CE) is a commonly used tool in the analysis of fluorescently labeled PCR amplification products. We have identified a CE artifact caused by the tissue stain eosin that can complicate the interpretation of CE data. The artifact was detected during routine analysis of a DNA sample isolated from a formalin-fixed, paraffin-embedded tissue sample considered histologically suspicious for a B-cell neoplasm. A standard clinical PCR and CE assay for immunoglobulin heavy chain (IGH) gene rearrangement revealed a weak polyclonal population of rearranged IGH genes and a 71 base peak suspicious for IGH clonality. The spectral properties of the 71 base peak were unusual in that although the dominant fluorescence of the peak was blue, it also fluoresced in green and yellow (blue>green>yellow), raising the suspicion that the peak might represent an artifact. CE analysis of the genomic DNA sample without PCR amplification demonstrated the presence of the 71 base peak, suggesting that the artifact was caused by a contaminant within the DNA sample itself. We demonstrate that eosin, which was used to stain the formalin-fixed tissue during processing, yields a discrete 71 base peak of similar morphology to the contaminant peak on CE analysis. The data suggest that eosin in the fixed tissue was not completely eliminated during nucleic acid extraction, resulting in the artifact peak. We discuss the implications of this potentially common contaminant on the interpretation of CE data and demonstrate that artifacts caused by eosin can be avoided by using more stringent DNA purification steps. Histological dyes may fluoresce, and artifacts from them should be considered when primary peaks contain additional underlying peaks of other colors. PMID:15681487

  12. Quantification of Artifact Reduction With Real-Time Cine Four-Dimensional Computed Tomography Acquisition Methods

    International Nuclear Information System (INIS)

    Langner, Ulrich W.; Keall, Paul J.

    2010-01-01

    Purpose: To quantify the magnitude and frequency of artifacts in simulated four-dimensional computed tomography (4D CT) images using three real-time acquisition methods- direction-dependent displacement acquisition, simultaneous displacement and phase acquisition, and simultaneous displacement and velocity acquisition- and to compare these methods with commonly used retrospective phase sorting. Methods and Materials: Image acquisition for the four 4D CT methods was simulated with different displacement and velocity tolerances for spheres with radii of 0.5 cm, 1.5 cm, and 2.5 cm, using 58 patient-measured tumors and respiratory motion traces. The magnitude and frequency of artifacts, CT doses, and acquisition times were computed for each method. Results: The mean artifact magnitude was 50% smaller for the three real-time methods than for retrospective phase sorting. The dose was ∼50% lower, but the acquisition time was 20% to 100% longer for the real-time methods than for retrospective phase sorting. Conclusions: Real-time acquisition methods can reduce the frequency and magnitude of artifacts in 4D CT images, as well as the imaging dose, but they increase the image acquisition time. The results suggest that direction-dependent displacement acquisition is the preferred real-time 4D CT acquisition method, because on average, the lowest dose is delivered to the patient and the acquisition time is the shortest for the resulting number and magnitude of artifacts.

  13. Online artifact removal for brain-computer interfaces using support vector machines and blind source separation.

    Science.gov (United States)

    Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang

    2007-01-01

    We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic (EOG) artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method.

  14. Pitfalls and artifacts in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kulkarni, M.V.; Patton, J.A.

    1986-01-01

    As a new imaging technique, MRI is subject to new and unfamiliar artifacts. Because of the wide range of pulse sequences used in MRI, the technique is prone to some artifacts, such as even echo rephasing, which are not found in other imaging systems. With newer and stronger magnetic fields, artifacts such as those caused by chemical shift will be more pronounced. For the maintenance of high quality images, new techniques controlling quality are essential. These techniques include the development of new phantoms and new procedures. The American Association of Physicists in Medicine is currently developing guidelines for quality assurance programs. As with other imaging modalities, these quality assurance guidelines could be unique to MRI. The daily or weekly evaluation of signal-to-noise ratio, image uniformity, signal linearity, spatial linearity, spatial resolution, frequencies, etc. is essential. Some guidelines are described in the current literature. With further modifications and improvements in MRI techniques, new artifacts may be discovered. Identification of these artifacts will improve the interpretation of the image and patient management

  15. Artifacts Quantification of Metal Implants in MRI

    Science.gov (United States)

    Vrachnis, I. N.; Vlachopoulos, G. F.; Maris, T. G.; Costaridou, L. I.

    2017-11-01

    The presence of materials with different magnetic properties, such as metal implants, causes distortion of the magnetic field locally, resulting in signal voids and pile ups, i.e. susceptibility artifacts in MRI. Quantitative and unbiased measurement of the artifact is prerequisite for optimization of acquisition parameters. In this study an image gradient based segmentation method is proposed for susceptibility artifact quantification. The method captures abrupt signal alterations by calculation of the image gradient. Then the artifact is quantified in terms of its extent by an automated cross entropy thresholding method as image area percentage. The proposed method for artifact quantification was tested in phantoms containing two orthopedic implants with significantly different magnetic permeabilities. The method was compared against a method proposed in the literature, considered as a reference, demonstrating moderate to good correlation (Spearman’s rho = 0.62 and 0.802 in case of titanium and stainless steel implants). The automated character of the proposed quantification method seems promising towards MRI acquisition parameter optimization.

  16. Metallic artifacts in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Abe, Eiji; Okuyama, Koichiro; Ishikawa, Noriyuki; Hongo, Michio; Sato, Kozo; Sashi, Ryuji; Ishikawa, Eijiro.

    1995-01-01

    Seven metallic implants with different content of magnetic materials were compared in terms of the degree of MRI artifact. The degree of artifact well correlated with the total content of iron and cobalt than the total content of ferromagnets (iron, cobalt, nickel). No significant difference was observed regarding artifact among 4 titanium alloys containing very small amount of ferromagnet (0.058%-2.5%). Pedicle screws were made from different alloys in the same shape. Those screws were inserted into the swine vertebrae and artifact was evaluated by MRI. The degree of artifact was SUS316 (stainless steel)>MP-35N (cobalt alloy)>Ti-6AI-4V (titanium alloy), 1.5 Tesla>0.5 Tesla as for magnetic intensity, and T2 (gradient echo)>T2 (long SE)>proton density>T1 as for exposure condition. The condition of the site screw was inserted in the vertebral canal was detectable by T1-weighted images of titanium alloy and cobalt alloy in 0.5 Tesla and T1-weighted images of titanium alloy in 1.5 Tesla. (S.Y)

  17. FACET - a "Flexible Artifact Correction and Evaluation Toolbox" for concurrently recorded EEG/fMRI data.

    Science.gov (United States)

    Glaser, Johann; Beisteiner, Roland; Bauer, Herbert; Fischmeister, Florian Ph S

    2013-11-09

    In concurrent EEG/fMRI recordings, EEG data are impaired by the fMRI gradient artifacts which exceed the EEG signal by several orders of magnitude. While several algorithms exist to correct the EEG data, these algorithms lack the flexibility to either leave out or add new steps. The here presented open-source MATLAB toolbox FACET is a modular toolbox for the fast and flexible correction and evaluation of imaging artifacts from concurrently recorded EEG datasets. It consists of an Analysis, a Correction and an Evaluation framework allowing the user to choose from different artifact correction methods with various pre- and post-processing steps to form flexible combinations. The quality of the chosen correction approach can then be evaluated and compared to different settings. FACET was evaluated on a dataset provided with the FMRIB plugin for EEGLAB using two different correction approaches: Averaged Artifact Subtraction (AAS, Allen et al., NeuroImage 12(2):230-239, 2000) and the FMRI Artifact Slice Template Removal (FASTR, Niazy et al., NeuroImage 28(3):720-737, 2005). Evaluation of the obtained results were compared to the FASTR algorithm implemented in the EEGLAB plugin FMRIB. No differences were found between the FACET implementation of FASTR and the original algorithm across all gradient artifact relevant performance indices. The FACET toolbox not only provides facilities for all three modalities: data analysis, artifact correction as well as evaluation and documentation of the results but it also offers an easily extendable framework for development and evaluation of new approaches.

  18. Markerless motion estimation for motion-compensated clinical brain imaging

    Science.gov (United States)

    Kyme, Andre Z.; Se, Stephen; Meikle, Steven R.; Fulton, Roger R.

    2018-05-01

    Motion-compensated brain imaging can dramatically reduce the artifacts and quantitative degradation associated with voluntary and involuntary subject head motion during positron emission tomography (PET), single photon emission computed tomography (SPECT) and computed tomography (CT). However, motion-compensated imaging protocols are not in widespread clinical use for these modalities. A key reason for this seems to be the lack of a practical motion tracking technology that allows for smooth and reliable integration of motion-compensated imaging protocols in the clinical setting. We seek to address this problem by investigating the feasibility of a highly versatile optical motion tracking method for PET, SPECT and CT geometries. The method requires no attached markers, relying exclusively on the detection and matching of distinctive facial features. We studied the accuracy of this method in 16 volunteers in a mock imaging scenario by comparing the estimated motion with an accurate marker-based method used in applications such as image guided surgery. A range of techniques to optimize performance of the method were also studied. Our results show that the markerless motion tracking method is highly accurate (brain imaging and holds good promise for a practical implementation in clinical PET, SPECT and CT systems.

  19. Artifact removal algorithms for stroke detection using a multistatic MIST beamforming algorithm.

    Science.gov (United States)

    Ricci, E; Di Domenico, S; Cianca, E; Rossi, T

    2015-01-01

    Microwave imaging (MWI) has been recently proved as a promising imaging modality for low-complexity, low-cost and fast brain imaging tools, which could play a fundamental role to efficiently manage emergencies related to stroke and hemorrhages. This paper focuses on the UWB radar imaging approach and in particular on the processing algorithms of the backscattered signals. Assuming the use of the multistatic version of the MIST (Microwave Imaging Space-Time) beamforming algorithm, developed by Hagness et al. for the early detection of breast cancer, the paper proposes and compares two artifact removal algorithms. Artifacts removal is an essential step of any UWB radar imaging system and currently considered artifact removal algorithms have been shown not to be effective in the specific scenario of brain imaging. First of all, the paper proposes modifications of a known artifact removal algorithm. These modifications are shown to be effective to achieve good localization accuracy and lower false positives. However, the main contribution is the proposal of an artifact removal algorithm based on statistical methods, which allows to achieve even better performance but with much lower computational complexity.

  20. Dual Adaptive Filtering by Optimal Projection Applied to Filter Muscle Artifacts on EEG and Comparative Study

    Directory of Open Access Journals (Sweden)

    Samuel Boudet

    2014-01-01

    Full Text Available Muscle artifacts constitute one of the major problems in electroencephalogram (EEG examinations, particularly for the diagnosis of epilepsy, where pathological rhythms occur within the same frequency bands as those of artifacts. This paper proposes to use the method dual adaptive filtering by optimal projection (DAFOP to automatically remove artifacts while preserving true cerebral signals. DAFOP is a two-step method. The first step consists in applying the common spatial pattern (CSP method to two frequency windows to identify the slowest components which will be considered as cerebral sources. The two frequency windows are defined by optimizing convolutional filters. The second step consists in using a regression method to reconstruct the signal independently within various frequency windows. This method was evaluated by two neurologists on a selection of 114 pages with muscle artifacts, from 20 clinical recordings of awake and sleeping adults, subject to pathological signals and epileptic seizures. A blind comparison was then conducted with the canonical correlation analysis (CCA method and conventional low-pass filtering at 30 Hz. The filtering rate was 84.3% for muscle artifacts with a 6.4% reduction of cerebral signals even for the fastest waves. DAFOP was found to be significantly more efficient than CCA and 30 Hz filters. The DAFOP method is fast and automatic and can be easily used in clinical EEG recordings.

  1. Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation.

    Science.gov (United States)

    Leardini, Alberto; Chiari, Lorenzo; Della Croce, Ugo; Cappozzo, Aurelio

    2005-02-01

    When using optoelectronic stereophotogrammetry, skin deformation and displacement causes marker movement with respect to the underlying bone. This movement represents an artifact, which affects the estimation of the skeletal system kinematics, and is regarded as the most critical source of error in human movement analysis. A comprehensive review of the state-of-the-art for assessment, minimization and compensation of the soft tissue artifact (STA) is provided. It has been shown that STA is greater than the instrumental error associated with stereophotogrammetry, has a frequency content similar to the actual bone movement, is task dependent and not reproducible among subjects and, of lower limb segments, is greatest at the thigh. It has been shown that in in vivo experiments only motion about the flexion/extension axis of the hip, knees and ankles can be determined reliably. Motion about other axes at those joints should be regarded with much more caution as this artifact produces spurious effects with magnitudes comparable to the amount of motion actually occurring in those joints. Techniques designed to minimize the contribution of and compensate for the effects of this artifact can be divided up into those which model the skin surface and those which include joint motion constraints. Despite the numerous solutions proposed, the objective of reliable estimation of 3D skeletal system kinematics using skin markers has not yet been satisfactorily achieved and greatly limits the contribution of human movement analysis to clinical practice and biomechanical research. For STA to be compensated for effectively, it is here suggested that either its subject-specific pattern is assessed by ad hoc exercises or it is characterized from a large series of measurements on different subject populations. Alternatively, inclusion of joint constraints into a more general STA minimization approach may provide an acceptable solution.

  2. Superluminal motion (review)

    Science.gov (United States)

    Malykin, G. B.; Romanets, E. A.

    2012-06-01

    Prior to the development of Special Relativity, no restrictions were imposed on the velocity of the motion of particles and material bodies, as well as on energy transfer and signal propagation. At the end of the 19th century and the beginning of the 20th century, it was shown that a charge that moves at a velocity faster than the speed of light in an optical medium, in particular, in vacuum, gives rise to impact radiation, which later was termed the Vavilov-Cherenkov radiation. Shortly after the development of Special Relativity, some researchers considered the possibility of superluminal motion. In 1923, the Soviet physicist L.Ya. Strum suggested the existence of tachyons, which, however, have not been discovered yet. Superluminal motions can occur only for images, e.g., for so-called "light spots," which were considered in 1972 by V.L. Ginzburg and B.M. Bolotovskii. These spots can move with a superluminal phase velocity but are incapable of transferring energy and information. Nevertheless, these light spots may induce quite real generation of microwave radiation in closed waveguides and create the Vavilov-Cherenkov radiation in vacuum. In this work, we consider various paradoxes, illusions, and artifacts associated with superluminal motion.

  3. Five-dimensional motion compensation for respiratory and cardiac motion with cone-beam CT of the thorax region

    Science.gov (United States)

    Sauppe, Sebastian; Hahn, Andreas; Brehm, Marcus; Paysan, Pascal; Seghers, Dieter; Kachelrieß, Marc

    2016-03-01

    We propose an adapted method of our previously published five-dimensional (5D) motion compensation (MoCo) algorithm1, developed for micro-CT imaging of small animals, to provide for the first time motion artifact-free 5D cone-beam CT (CBCT) images from a conventional flat detector-based CBCT scan of clinical patients. Image quality of retrospectively respiratory- and cardiac-gated volumes from flat detector CBCT scans is deteriorated by severe sparse projection artifacts. These artifacts further complicate motion estimation, as it is required for MoCo image reconstruction. For high quality 5D CBCT images at the same x-ray dose and the same number of projections as todays 3D CBCT we developed a double MoCo approach based on motion vector fields (MVFs) for respiratory and cardiac motion. In a first step our already published four-dimensional (4D) artifact-specific cyclic motion-compensation (acMoCo) approach is applied to compensate for the respiratory patient motion. With this information a cyclic phase-gated deformable heart registration algorithm is applied to the respiratory motion-compensated 4D CBCT data, thus resulting in cardiac MVFs. We apply these MVFs on double-gated images and thereby respiratory and cardiac motion-compensated 5D CBCT images are obtained. Our 5D MoCo approach processing patient data acquired with the TrueBeam 4D CBCT system (Varian Medical Systems). Our double MoCo approach turned out to be very efficient and removed nearly all streak artifacts due to making use of 100% of the projection data for each reconstructed frame. The 5D MoCo patient data show fine details and no motion blurring, even in regions close to the heart where motion is fastest.

  4. Fast MR imaging and ultrafast MR imaging of fetal central nervous system abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Shakudo, Miyuki; Manabe, Takao; Murata, Katsuko; Matsuo, Ryoichi; Oda, Junro [Osaka City General Hospital (Japan); Inoue, Yuichi; Mochizuki, Kunizo; Yamada, Ryusaku

    2001-12-01

    The aims of this study were two: to compare the efficacy of fast MRI (breath-hold fast spin-echo T2-weighted and fast gradient-echo T1-weighted sequence) and ultrafast MRI (half-Fourier acquisition single-shot turbo spin-echo sequence) in evaluation of fetal central nervous system (CNS) abnormalities at late gestational age, and to compare the capability of fast MRI and ultrafast MRI to assess fetal CNS abnormalities with that of prenatal ultrasonography (US). Forty-nine women with fetuses at gestational ages of 26-39 weeks underwent fast MRI (29 patients) or ultrafast MRI (20 patients). In detection of motion artifact, visualization of the lateral and 4th ventricles, and differentiation between gray and white matter in cerebral hemispheres, ultrafast MRI was significantly superior to fast MRI (p<0.0001, Mann-Whitney U test). In 25 of 43 cases, US and MR diagnoses were the same and consistent with postnatal diagnosis. In 10 of 43 cases, MRI demonstrated findings additional to or different from those of US, and MR findings were confirmed postnatally. MRI, particularly ultrafast MRI, is useful for demonstrating CNS abnormalities in situations in which US is suggestive but not definitive. (author)

  5. Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers

    International Nuclear Information System (INIS)

    Toftegaard, Jakob; Fledelius, Walther; Worm, Esben S.; Poulsen, Per R.; Seghers, Dieter; Huber, Michael; Brehm, Marcus; Elstrøm, Ulrik V.

    2014-01-01

    Purpose: Implanted gold markers for image-guided radiotherapy lead to streaking artifacts in cone-beam CT (CBCT) scans. Several methods for metal artifact reduction (MAR) have been published, but they all fail in scans with large motion. Here the authors propose and investigate a method for automatic moving metal artifact reduction (MMAR) in CBCT scans with cylindrical gold markers. Methods: The MMAR CBCT reconstruction method has six steps. (1) Automatic segmentation of the cylindrical markers in the CBCT projections. (2) Removal of each marker in the projections by replacing the pixels within a masked area with interpolated values. (3) Reconstruction of a marker-free CBCT volume from the manipulated CBCT projections. (4) Reconstruction of a standard CBCT volume with metal artifacts from the original CBCT projections. (5) Estimation of the three-dimensional (3D) trajectory during CBCT acquisition for each marker based on the segmentation in Step 1, and identification of the smallest ellipsoidal volume that encompasses 95% of the visited 3D positions. (6) Generation of the final MMAR CBCT reconstruction from the marker-free CBCT volume of Step 3 by replacing the voxels in the 95% ellipsoid with the corresponding voxels of the standard CBCT volume of Step 4. The MMAR reconstruction was performed retrospectively using a half-fan CBCT scan for 29 consecutive stereotactic body radiation therapy patients with 2–3 gold markers implanted in the liver. The metal artifacts of the MMAR reconstructions were scored and compared with a standard MAR reconstruction by counting the streaks and by calculating the standard deviation of the Hounsfield units in a region around each marker. Results: The markers were found with the same autosegmentation settings in 27 CBCT scans, while two scans needed slightly changed settings to find all markers automatically in Step 1 of the MMAR method. MMAR resulted in 15 scans with no streaking artifacts, 11 scans with 1–4 streaks, and 3 scans

  6. Dynamics of Change in Human-Driven and Natural Systems: Fast Forward, Slow Motion, Same Movie? A Case Study from Plant Protection

    Directory of Open Access Journals (Sweden)

    Didier Andrivon

    2012-03-01

    Full Text Available Evolutionary biology and evolutionary ecology deal with change in species and ecosystems over time, and propose mechanisms to explain and predict these. In particular, they look for generic elements that will drive any organism or phylum to adaptive changes or to extinction. This paper, using examples from the field of plant protection against pests and diseases, shows that the patterns of change observed in natural and in human-driven systems are comparable, and proposes that their similarities result from the same mechanisms operating at different paces. Human-driven systems can thus be seen simply as ‘fast-forward’ versions of natural systems, making them tractable tools to test and predict elements from evolutionary theory. Conversely, the convergence between natural and human-driven systems opens opportunities for a more widespread use of evolutionary theory when analyzing and optimizing any human-driven system, or predicting its adaptability to changing conditions.

  7. Fast High-Quality Noise

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Wyvill, Geoff

    2007-01-01

    At the moment the noise functions available in a graphics programmer's toolbox are either slow to compute or they involve grid-line artifacts making them of lower quality. In this paper we present a real-time noise computation with no grid-line artifacts or other regularity problems. In other words......, we put a new tool in the box that computes fast high-quality noise. In addition to being free of artifacts, the noise we present does not rely on tabulated data (everything is computed on the fly) and it is easy to adjust quality vs. quantity for the noise. The noise is based on point rendering (like...... spot noise), but it extends to more than two dimensions. The fact that it is based on point rendering makes art direction of the noise much easier....

  8. Motion tolerant iterative reconstruction algorithm for cone-beam helical CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hisashi; Goto, Taiga; Hirokawa, Koichi; Miyazaki, Osamu [Hitachi Medical Corporation, Chiba-ken (Japan). CT System Div.

    2011-07-01

    We have developed a new advanced iterative reconstruction algorithm for cone-beam helical CT. The features of this algorithm are: (a) it uses separable paraboloidal surrogate (SPS) technique as a foundation for reconstruction to reduce noise and cone-beam artifact, (b) it uses a view weight in the back-projection process to reduce motion artifact. To confirm the improvement of our proposed algorithm over other existing algorithm, such as Feldkamp-Davis-Kress (FDK) or SPS algorithm, we compared the motion artifact reduction, image noise reduction (standard deviation of CT number), and cone-beam artifact reduction on simulated and clinical data set. Our results demonstrate that the proposed algorithm dramatically reduces motion artifacts compared with the SPS algorithm, and decreases image noise compared with the FDK algorithm. In addition, the proposed algorithm potentially improves time resolution of iterative reconstruction. (orig.)

  9. [E-MTAB-587] PCR_artifacts

    NARCIS (Netherlands)

    Muino Acuna, J.M.

    2011-01-01

    WARNING: This library was yield low amount of material and it was over-amplified by PCR. This libraries are used study the robustness of several statitical methods against PCR artifacts. ChIP experiments were performed on Arabidopsis wildtype inflorescences using an antibody raised against a

  10. Mediating Artifact in Teacher Professional Development

    Science.gov (United States)

    Svendsen, Bodil

    2015-01-01

    This article focuses on teacher professional development (TPD) in natural science through the 5E model as mediating artifact. The study was conducted in an upper secondary school, grounded in a school-based intervention research project. My contribution to the field of research on TPD is founded on the hypothesis that teachers would be best…

  11. Cooperative learning, problem solving and mediating artifacts

    African Journals Online (AJOL)

    PROF.MIREKU

    10, 2012. 39. Cooperative learning, problem solving and mediating artifacts. F. Bahmaei6 & N. ... out cooperative learning in the end, post-test was done and by analyzing the tests it was concluded that ... Johnson et al, 1991 b, Reynolds et al. 1995, Vidakovic .... connection of mental constructs (Hiebert, Carpenter, 1992).

  12. Online Artifact Removal for Brain-Computer Interfaces Using Support Vector Machines and Blind Source Separation

    OpenAIRE

    Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang

    2007-01-01

    We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic...

  13. relaxGUI: a new software for fast and simple NMR relaxation data analysis and calculation of ps-ns and μs motion of proteins

    International Nuclear Information System (INIS)

    Bieri, Michael; D’Auvergne, Edward J.; Gooley, Paul R.

    2011-01-01

    Investigation of protein dynamics on the ps-ns and μs-ms timeframes provides detailed insight into the mechanisms of enzymes and the binding properties of proteins. Nuclear magnetic resonance (NMR) is an excellent tool for studying protein dynamics at atomic resolution. Analysis of relaxation data using model-free analysis can be a tedious and time consuming process, which requires good knowledge of scripting procedures. The software relaxGUI was developed for fast and simple model-free analysis and is fully integrated into the software package relax. It is written in Python and uses wxPython to build the graphical user interface (GUI) for maximum performance and multi-platform use. This software allows the analysis of NMR relaxation data with ease and the generation of publication quality graphs as well as color coded images of molecular structures. The interface is designed for simple data analysis and management. The software was tested and validated against the command line version of relax.

  14. relaxGUI: a new software for fast and simple NMR relaxation data analysis and calculation of ps-ns and μs motion of proteins.

    Science.gov (United States)

    Bieri, Michael; d'Auvergne, Edward J; Gooley, Paul R

    2011-06-01

    Investigation of protein dynamics on the ps-ns and μs-ms timeframes provides detailed insight into the mechanisms of enzymes and the binding properties of proteins. Nuclear magnetic resonance (NMR) is an excellent tool for studying protein dynamics at atomic resolution. Analysis of relaxation data using model-free analysis can be a tedious and time consuming process, which requires good knowledge of scripting procedures. The software relaxGUI was developed for fast and simple model-free analysis and is fully integrated into the software package relax. It is written in Python and uses wxPython to build the graphical user interface (GUI) for maximum performance and multi-platform use. This software allows the analysis of NMR relaxation data with ease and the generation of publication quality graphs as well as color coded images of molecular structures. The interface is designed for simple data analysis and management. The software was tested and validated against the command line version of relax.

  15. Bias field inconsistency correction of motion-scattered multislice MRI for improved 3D image reconstruction.

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A; Rajagopalan, Vidya; Scott, Julia A; Corbett-Detig, James M; Rousseau, Francois; Barkovich, A James; Glenn, Orit A; Studholme, Colin

    2011-09-01

    A common solution to clinical MR imaging in the presence of large anatomical motion is to use fast multislice 2D studies to reduce slice acquisition time and provide clinically usable slice data. Recently, techniques have been developed which retrospectively correct large scale 3D motion between individual slices allowing the formation of a geometrically correct 3D volume from the multiple slice stacks. One challenge, however, in the final reconstruction process is the possibility of varying intensity bias in the slice data, typically due to the motion of the anatomy relative to imaging coils. As a result, slices which cover the same region of anatomy at different times may exhibit different sensitivity. This bias field inconsistency can induce artifacts in the final 3D reconstruction that can impact both clinical interpretation of key tissue boundaries and the automated analysis of the data. Here we describe a framework to estimate and correct the bias field inconsistency in each slice collectively across all motion corrupted image slices. Experiments using synthetic and clinical data show that the proposed method reduces intensity variability in tissues and improves the distinction between key tissue types.

  16. A Single Image Deblurring Algorithm for Nonuniform Motion Blur Using Uniform Defocus Map Estimation

    Directory of Open Access Journals (Sweden)

    Chia-Feng Chang

    2017-01-01

    Full Text Available One of the most common artifacts in digital photography is motion blur. When capturing an image under dim light by using a handheld camera, the tendency of the photographer’s hand to shake causes the image to blur. In response to this problem, image deblurring has become an active topic in computational photography and image processing in recent years. From the view of signal processing, image deblurring can be reduced to a deconvolution problem if the kernel function of the motion blur is assumed to be shift invariant. However, the kernel function is not always shift invariant in real cases; for example, in-plane rotation of a camera or a moving object can blur different parts of an image according to different kernel functions. An image that is degraded by multiple blur kernels is called a nonuniform blur image. In this paper, we propose a novel single image deblurring algorithm for nonuniform motion blur images that is blurred by moving object. First, a proposed uniform defocus map method is presented for measurement of the amounts and directions of motion blur. These blurred regions are then used to estimate point spread functions simultaneously. Finally, a fast deconvolution algorithm is used to restore the nonuniform blur image. We expect that the proposed method can achieve satisfactory deblurring of a single nonuniform blur image.

  17. An image-based approach to understanding the physics of MR artifacts.

    Science.gov (United States)

    Morelli, John N; Runge, Val M; Ai, Fei; Attenberger, Ulrike; Vu, Lan; Schmeets, Stuart H; Nitz, Wolfgang R; Kirsch, John E

    2011-01-01

    As clinical magnetic resonance (MR) imaging becomes more versatile and more complex, it is increasingly difficult to develop and maintain a thorough understanding of the physical principles that govern the changing technology. This is particularly true for practicing radiologists, whose primary obligation is to interpret clinical images and not necessarily to understand complex equations describing the underlying physics. Nevertheless, the physics of MR imaging plays an important role in clinical practice because it determines image quality, and suboptimal image quality may hinder accurate diagnosis. This article provides an image-based explanation of the physics underlying common MR imaging artifacts, offering simple solutions for remedying each type of artifact. Solutions that have emerged from recent technologic advances with which radiologists may not yet be familiar are described in detail. Types of artifacts discussed include those resulting from voluntary and involuntary patient motion, magnetic susceptibility, magnetic field inhomogeneities, gradient nonlinearity, standing waves, aliasing, chemical shift, and signal truncation. With an improved awareness and understanding of these artifacts, radiologists will be better able to modify MR imaging protocols so as to optimize clinical image quality, allowing greater confidence in diagnosis. Copyright © RSNA, 2011.

  18. Human-Robot Collaboration Dynamic Impact Testing and Calibration Instrument for Disposable Robot Safety Artifacts.

    Science.gov (United States)

    Dagalakis, Nicholas G; Yoo, Jae Myung; Oeste, Thomas

    2016-01-01

    The Dynamic Impact Testing and Calibration Instrument (DITCI) is a simple instrument with a significant data collection and analysis capability that is used for the testing and calibration of biosimulant human tissue artifacts. These artifacts may be used to measure the severity of injuries caused in the case of a robot impact with a human. In this paper we describe the DITCI adjustable impact and flexible foundation mechanism, which allows the selection of a variety of impact force levels and foundation stiffness. The instrument can accommodate arrays of a variety of sensors and impact tools, simulating both real manufacturing tools and the testing requirements of standards setting organizations. A computer data acquisition system may collect a variety of impact motion, force, and torque data, which are used to develop a variety of mathematical model representations of the artifacts. Finally, we describe the fabrication and testing of human abdomen soft tissue artifacts, used to display the magnitude of impact tissue deformation. Impact tests were performed at various maximum impact force and average pressure levels.

  19. Teaching and Learning the Nature of Technical Artifacts

    Science.gov (United States)

    Frederik, Ineke; Sonneveld, Wim; de Vries, Marc J.

    2011-01-01

    Artifacts are probably our most obvious everyday encounter with technology. Therefore, a good understanding of the nature of technical artifacts is a relevant part of technological literacy. In this article we draw from the philosophy of technology to develop a conceptualization of technical artifacts that can be used for educational purposes.…

  20. Guided interaction exploration in artifact-centric process models

    NARCIS (Netherlands)

    van Eck, M.L.; Sidorova, N.; van der Aalst, W.M.P.

    2017-01-01

    Artifact-centric process models aim to describe complex processes as a collection of interacting artifacts. Recent development in process mining allow for the discovery of such models. However, the focus is often on the representation of the individual artifacts rather than their interactions. Based

  1. Leap Motion development essentials

    CERN Document Server

    Spiegelmock, Mischa

    2013-01-01

    This book is a fast-paced guide with practical examples that aims to help you understand and master the Leap Motion SDK.This book is for developers who are either involved in game development or who are looking to utilize Leap Motion technology in order to create brand new user interaction experiences to distinguish their products from the mass market. You should be comfortable with high-level languages and object-oriented development concepts in order to get the most out of this book.

  2. Supporting Knowledge Transfer through Decomposable Reasoning Artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Pike, William A.; May, Richard A.; Turner, Alan E.

    2007-01-03

    Technology to support knowledge transfer and cooperative inquiry must offer its users the ability to effectively interpret knowledge structures produced by collaborators. Communicating the reasoning processes that underlie a finding is one method for enhancing interpretation, and can result in more effective evaluation and application of shared knowledge. In knowledge management tools, interpretation is aided by creating knowledge artifacts that can expose their provenance to scrutiny and that can be transformed into diverse representations that suit their consumers’ perspectives and preferences. We outline the information management needs of inquiring communities characterized by hypothesis generation tasks, and propose a model for communication, based in theories of hermeneutics, semiotics, and abduction, in which knowledge structures can be decomposed into the lower-level reasoning artifacts that produced them. We then present a proof-of-concept implementation for an environment to support the capture and communication of analytic products, with emphasis on the domain of intelligence analysis.

  3. A Language of Objects and Artifacts

    DEFF Research Database (Denmark)

    Svabo, Connie

    This is a conceptual inquiry about materiality. It gives an introductory overview to the vocabulary of materiality in a chosen selection of theories. The paper shows a language of artifacts and objects as it is used within practice-based approaches to organizational knowing. The examined...... intellectual traditions are interpretive-cultural approaches; activity theory; and sociology of translation. Similarities and differences are presented in the way these three distinct intellectual traditions conceptualize the array of material objects and artifacts which are central in the tales of practice...... concepts do the theories attempt to grasp tools and design objects – furniture, graphics, flutes-in-making and built space? The paper shows which concepts are used and it demonstrates how the interaction between social and material realities are viewed. Furthermore it highlights some of the ontological...

  4. Panning artifacts in digital pathology images

    Science.gov (United States)

    Avanaki, Ali R. N.; Lanciault, Christian; Espig, Kathryn S.; Xthona, Albert; Kimpe, Tom R. L.

    2017-03-01

    In making a pathologic diagnosis, a pathologist uses cognitive processes: perception, attention, memory, and search (Pena and Andrade-Filho, 2009). Typically, this involves focus while panning from one region of a slide to another, using either a microscope in a traditional workflow or software program and display in a digital pathology workflow (DICOM Standard Committee, 2010). We theorize that during panning operation, the pathologist receives information important to diagnosis efficiency and/or correctness. As compared to an optical microscope, panning in a digital pathology image involves some visual artifacts due to the following: (i) the frame rate is finite; (ii) time varying visual signals are reconstructed using imperfect zero-order hold. Specifically, after pixel's digital drive is changed, it takes time for a pixel to emit the expected amount of light. Previous work suggests that 49% of navigation is conducted in low-power/overview with digital pathology (Molin et al., 2015), but the influence of display factors has not been measured. We conducted a reader study to establish a relationship between display frame rate, panel response time, and threshold panning speed (above which the artifacts become noticeable). Our results suggest visual tasks that involve tissue structure are more impacted by the simulated panning artifacts than those that only involve color (e.g., staining intensity estimation), and that the panning artifacts versus normalized panning speed has a peak behavior which is surprising and may change for a diagnostic task. This is work in progress and our final findings should be considered in designing future digital pathology systems.

  5. An EEG Data Investigation Using Only Artifacts

    Science.gov (United States)

    2017-02-22

    hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and...some conditions, an automation feature was implemented to help the participants find the HVT. When the HVT was within the sensor footprint, a tone...EEG Data Investigation Using Only Artifacts 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 1 Chelsey

  6. Awe and Artifacts: Religious and Scientific Endeavor

    Directory of Open Access Journals (Sweden)

    Ionut Untea

    2017-05-01

    Full Text Available The article takes as its point of departure the reflections of Henry Adams and Jacques Ellul on the possible gradual replacement of objects used in religious worship with objects used in technological worship, and advances the hypothesis that such a substitution is unlikely. Using information from psychology, history of religions, and history of science, the perspective proposed is that of a parallel historical analogous development of both religious and scientific attitudes of awe by the use of artifacts carrying two functions: firstly, to coagulate social participation around questions dealing with humanity’s destiny and interpersonal relationships across communities, and secondly to offer cultural coherence through a communal sense of social stability, comfort, and security. I argue that, though animated by attitudes of awe (“awefull”, both leading scientists and religious founders have encountered the difficulty in representing and introducing this awe to the large public via “awesome” artifacts. The failure to represent coherently the initial awe via artifacts may give rise to “anomalous awefullness”: intolerance, persecutions, global conflicts.

  7. A Compact Closed-Loop Optogenetics System Based on Artifact-Free Transparent Graphene Electrodes

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2018-03-01

    Full Text Available Electrophysiology is a decades-old technique widely used for monitoring activity of individual neurons and local field potentials. Optogenetics has revolutionized neuroscience studies by offering selective and fast control of targeted neurons and neuron populations. The combination of these two techniques is crucial for causal investigation of neural circuits and understanding their functional connectivity. However, electrical artifacts generated by light stimulation interfere with neural recordings and hinder the development of compact closed-loop systems for precise control of neural activity. Here, we demonstrate that transparent graphene micro-electrodes fabricated on a clear polyethylene terephthalate film eliminate the light-induced artifact problem and allow development of a compact battery-powered closed-loop optogenetics system. We extensively investigate light-induced artifacts for graphene electrodes in comparison to metal control electrodes. We then design optical stimulation module using micro-LED chips coupled to optical fibers to deliver light to intended depth for optogenetic stimulation. For artifact-free integration of graphene micro-electrode recordings with optogenetic stimulation, we design and develop a compact closed-loop system and validate it for different frequencies of interest for neural recordings. This compact closed-loop optogenetics system can be used for various applications involving optogenetic stimulation and electrophysiological recordings.

  8. Voting strategy for artifact reduction in digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Wu Tao; Moore, Richard H.; Kopans, Daniel B.

    2006-01-01

    Artifacts are observed in digital breast tomosynthesis (DBT) reconstructions due to the small number of projections and the narrow angular range that are typically employed in tomosynthesis imaging. In this work, we investigate the reconstruction artifacts that are caused by high-attenuation features in breast and develop several artifact reduction methods based on a 'voting strategy'. The voting strategy identifies the projection(s) that would introduce artifacts to a voxel and rejects the projection(s) when reconstructing the voxel. Four approaches to the voting strategy were compared, including projection segmentation, maximum contribution deduction, one-step classification, and iterative classification. The projection segmentation method, based on segmentation of high-attenuation features from the projections, effectively reduces artifacts caused by metal and large calcifications that can be reliably detected and segmented from projections. The other three methods are based on the observation that contributions from artifact-inducing projections have higher value than those from normal projections. These methods attempt to identify the projection(s) that would cause artifacts by comparing contributions from different projections. Among the three methods, the iterative classification method provides the best artifact reduction; however, it can generate many false positive classifications that degrade the image quality. The maximum contribution deduction method and one-step classification method both reduce artifacts well from small calcifications, although the performance of artifact reduction is slightly better with the one-step classification. The combination of one-step classification and projection segmentation removes artifacts from both large and small calcifications

  9. Fast optical signal not detected in awake behaving monkeys.

    Science.gov (United States)

    Radhakrishnan, Harsha; Vanduffel, Wim; Deng, Hong Ping; Ekstrom, Leeland; Boas, David A; Franceschini, Maria Angela

    2009-04-01

    While the ability of near-infrared spectroscopy (NIRS) to measure cerebral hemodynamic evoked responses (slow optical signal) is well established, its ability to measure non-invasively the 'fast optical signal' is still controversial. Here, we aim to determine the feasibility of performing NIRS measurements of the 'fast optical signal' or Event-Related Optical Signals (EROS) under optimal experimental conditions in awake behaving macaque monkeys. These monkeys were implanted with a 'recording well' to expose the dura above the primary visual cortex (V1). A custom-made optical probe was inserted and fixed into the well. The close proximity of the probe to the brain maximized the sensitivity to changes in optical properties in the cortex. Motion artifacts were minimized by physical restraint of the head. Full-field contrast-reversing checkerboard stimuli were presented to monkeys trained to perform a visual fixation task. In separate sessions, two NIRS systems (CW4 and ISS FD oximeter), which previously showed the ability to measure the fast signal in human, were used. In some sessions EEG was acquired simultaneously with the optical signal. The increased sensitivity to cortical optical changes with our experimental setup was quantified with 3D Monte Carlo simulations on a segmented MRI monkey head. Averages of thousands of stimuli in the same animal, or grand averages across the two animals and across repeated sessions, did not lead to detection of the fast optical signal using either amplitude or phase of the optical signal. Hemodynamic responses and visual evoked potentials were instead always detected with single trials or averages of a few stimuli. Based on these negative results, despite the optimal experimental conditions, we doubt the usefulness of non-invasive fast optical signal measurements with NIRS.

  10. Effects of Cable Sway, Electrode Surface Area, and Electrode Mass on Electroencephalography Signal Quality during Motion.

    Science.gov (United States)

    Symeonidou, Evangelia-Regkina; Nordin, Andrew D; Hairston, W David; Ferris, Daniel P

    2018-04-03

    More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The cause of motion artifacts in EEG is often attributed to electrode motion relative to the skin, but few studies have examined EEG signals under head motion. In the current study, we tested how motion artifacts are affected by the overall mass and surface area of commercially available electrodes, as well as how cable sway contributes to motion artifacts. To provide a ground-truth signal, we used a gelatin head phantom with embedded antennas broadcasting electrical signals, and recorded EEG with a commercially available electrode system. A robotic platform moved the phantom head through sinusoidal displacements at different frequencies (0-2 Hz). Results showed that a larger electrode surface area can have a small but significant effect on improving EEG signal quality during motion and that cable sway is a major contributor to motion artifacts. These results have implications in the development of future hardware for mobile brain imaging with EEG.

  11. Comparison of cardiac gating and refocusing pulses for correction of cerebrospinal fluid pulsation artifacts in MR images

    International Nuclear Information System (INIS)

    Modic, M.T.; Haacke, E.M.; Lenz, G.W.; Masaryk, T.; Kaufman, B.; Ross, J.S.

    1986-01-01

    This study compared cardiac gating and additional refocusing gradient pulses in combination or alone for correction of cerebrospinal fluid (CSF) pulsation artifacts in both normal volunteers and in patients with suspected spinal pathology. Refocusing pulses or cardiac gating when used alone produced a decrease in ghosting artifacts on sagittal images and reduced the nonuniformity of the CSF signal on axial images. There is improved thin-section T2 imaging of the cord with long TEs and as few as one excitation. The refocusing pulses reduced ghosting artifacts also from respiratory motion and enhanced the CSF signal with shorter TRs leading to increased CSF contrast. When used together, the results were significantly better than either alone. Refocusing schemes can be used with any TR, do not require gating, and are now routinely employed at the authors' institution

  12. Evaluation of two iterative techniques for reducing metal artifacts in computed tomography.

    Science.gov (United States)

    Boas, F Edward; Fleischmann, Dominik

    2011-06-01

    To evaluate two methods for reducing metal artifacts in computed tomography (CT)--the metal deletion technique (MDT) and the selective algebraic reconstruction technique (SART)--and compare these methods with filtered back projection (FBP) and linear interpolation (LI). The institutional review board approved this retrospective HIPAA-compliant study; informed patient consent was waived. Simulated projection data were calculated for a phantom that contained water, soft tissue, bone, and iron. Clinical projection data were obtained retrospectively from 11 consecutively identified CT scans with metal streak artifacts, with a total of 178 sections containing metal. Each scan was reconstructed using FBP, LI, SART, and MDT. The simulated scans were evaluated quantitatively by calculating the average error in Hounsfield units for each pixel compared with the original phantom. Two radiologists who were blinded to the reconstruction algorithms used qualitatively evaluated the clinical scans, ranking the overall severity of artifacts for each algorithm. P values for comparisons of the image quality ranks were calculated from the binomial distribution. The simulations showed that MDT reduces artifacts due to photon starvation, beam hardening, and motion and does not introduce new streaks between metal and bone. MDT had the lowest average error (76% less than FBP, 42% less than LI, 17% less than SART). Blinded comparison of the clinical scans revealed that MDT had the best image quality 100% of the time (95% confidence interval: 72%, 100%). LI had the second best image quality, and SART and FBP had the worst image quality. On images from two CT scans, as compared with images generated by the scanner, MDT revealed information of potential clinical importance. For a wide range of scans, MDT yields reduced metal streak artifacts and better-quality images than does FBP, LI, or SART. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101782/-/DC1. RSNA, 2011

  13. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph

    Directory of Open Access Journals (Sweden)

    Kristen M. Warren

    2016-03-01

    Full Text Available Photoplethysmographic (PPG waveforms are used to acquire pulse rate (PR measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA, limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.

  14. Motion correction improves image quality of dGEMRIC in finger joints

    International Nuclear Information System (INIS)

    Miese, Falk; Kröpil, Patric; Ostendorf, Benedikt; Scherer, Axel; Buchbender, Christian; Quentin, Michael; Lanzman, Rotem S.; Blondin, Dirk; Schneider, Matthias; Bittersohl, Bernd; Zilkens, Christoph; Jellus, Vladimir; Mamisch, Tallal Ch.; Wittsack, Hans-Jörg

    2011-01-01

    Purpose: To assess motion artifacts in dGEMRIC of finger joints and to evaluate the effectiveness of motion correction. Materials and methods: In 40 subjects (26 patients with finger arthritis and 14 healthy volunteers) dGEMRIC of metacarpophalangeal joint II was performed. Imaging used a dual flip angle approach (TE 3.72 ms, TR 15 ms, flip angles 5° and 26°). Two sets of T1 maps were calculated for dGEMRIC analysis from the imaging data for each subject: one with and one without motion correction. To compare image quality, visual grading analysis and precision of dGEMRIC measurement of both dGEMRIC maps for each case were evaluated. Results: Motion artifacts were present in 82% (33/40) of uncorrected dGEMRIC maps. Motion artifacts were graded as severe or as rendering evaluation impossible in 43% (17/40) of uncorrected dGEMRIC maps. Motion corrected maps showed significantly less motion artifacts (P < 0.001) and were graded as evaluable in 97% (39/40) of cases. Precision was significantly higher in motion corrected images (coefficient of variation (CV = .176 ± .077), compared to uncorrected images (CV .445 ± .347) (P < .001). Motion corrected dGERMIC was different in volunteers and patients (P = .044), whereas uncorrected dGEMRIC was not (P = .234). Conclusion: Motion correction improves image quality, dGEMRIC measurement precision and diagnostic performance in dGEMRIC of finger joints.

  15. Improving consensus structure by eliminating averaging artifacts

    Directory of Open Access Journals (Sweden)

    KC Dukka B

    2009-03-01

    Full Text Available Abstract Background Common structural biology methods (i.e., NMR and molecular dynamics often produce ensembles of molecular structures. Consequently, averaging of 3D coordinates of molecular structures (proteins and RNA is a frequent approach to obtain a consensus structure that is representative of the ensemble. However, when the structures are averaged, artifacts can result in unrealistic local geometries, including unphysical bond lengths and angles. Results Herein, we describe a method to derive representative structures while limiting the number of artifacts. Our approach is based on a Monte Carlo simulation technique that drives a starting structure (an extended or a 'close-by' structure towards the 'averaged structure' using a harmonic pseudo energy function. To assess the performance of the algorithm, we applied our approach to Cα models of 1364 proteins generated by the TASSER structure prediction algorithm. The average RMSD of the refined model from the native structure for the set becomes worse by a mere 0.08 Å compared to the average RMSD of the averaged structures from the native structure (3.28 Å for refined structures and 3.36 A for the averaged structures. However, the percentage of atoms involved in clashes is greatly reduced (from 63% to 1%; in fact, the majority of the refined proteins had zero clashes. Moreover, a small number (38 of refined structures resulted in lower RMSD to the native protein versus the averaged structure. Finally, compared to PULCHRA 1, our approach produces representative structure of similar RMSD quality, but with much fewer clashes. Conclusion The benchmarking results demonstrate that our approach for removing averaging artifacts can be very beneficial for the structural biology community. Furthermore, the same approach can be applied to almost any problem where averaging of 3D coordinates is performed. Namely, structure averaging is also commonly performed in RNA secondary prediction 2, which

  16. Iterative CT reconstruction with correction for known rigid motion

    Energy Technology Data Exchange (ETDEWEB)

    Nuyts, Johan [Katholieke Univ. Leuven (Belgium). Dept. of Nuclear Medicine; Kim, Jung-Ha; Fulton, Roger [Sydney Univ., NSW (Australia). School of Physics; Westmead Hospital, Sydney (Australia). Medical Physics

    2011-07-01

    In PET/CT brain imaging, correction for motion may be needed, in particular for children and psychiatric patients. Motion is more likely to occur in the lengthy PET measurement, but also during the short CT acquisition patient motion is possible. Rigid motion of the head can be measured independently from the PET/CT system with optical devices. In this paper, we propose a method and some preliminary simulation results for iterative CT reconstruction with correction for known rigid motion. We implemented an iterative algorithm for fully 3D reconstruction from helical CT scans. The motion of the head is incorporated in the system matrix as a view-dependent motion of the CT-system. The first simulation results indicate that some motion patterns may produce loss of essential data. This loss precludes exact reconstruction and results in artifacts in the reconstruction, even when motion is taken into account. However, by reducing the pitch during acquisition, the same motion pattern no longer caused artifacts in the motion corrected image. (orig.)

  17. Metallic artifact in MRI after removal of orthopedic implants

    International Nuclear Information System (INIS)

    Bagheri, Mohammad Hadi; Hosseini, Mehrdad Mohammad; Emami, Mohammad Jafar; Foroughi, Amin Aiboulhassani

    2012-01-01

    Objective: The aim of the present study was to evaluate the metallic artifacts in MRI of the orthopedic patients after removal of metallic implants. Subjects and methods: From March to August 2009, 40 orthopedic patients operated for removal of orthopedic metallic implants were studied by post-operative MRI from the site of removal of implants. A grading scale of 0–3 was assigned for artifact in MR images whereby 0 was considered no artifact; and I–III were considered mild, moderate, and severe metallic artifacts, respectively. These grading records were correlated with other variables including the type, size, number, and composition of metallic devices; and the site and duration of orthopedic devices stay in the body. Results: Metallic susceptibly artifacts were detected in MRI of 18 of 40 cases (45%). Screws and pins in removed hardware were the most important factors for causing artifacts in MRI. The artifacts were found more frequently in the patients who had more screws and pins in the removed implants. Gender, age, site of implantation of the device, length of the hardware, composition of the metallic implants (stainless steel versus titanium), and duration of implantation of the hardware exerted no effect in producing metallic artifacts after removal of implants. Short TE sequences of MRI (such as T1 weighted) showed fewer artifacts. Conclusion: Susceptibility of metallic artifacts is a frequent phenomenon in MRI of patients upon removal of metallic orthopedic implants.

  18. Metallic artifact in MRI after removal of orthopedic implants.

    Science.gov (United States)

    Bagheri, Mohammad Hadi; Hosseini, Mehrdad Mohammad; Emami, Mohammad Jafar; Foroughi, Amin Aiboulhassani

    2012-03-01

    The aim of the present study was to evaluate the metallic artifacts in MRI of the orthopedic patients after removal of metallic implants. From March to August 2009, 40 orthopedic patients operated for removal of orthopedic metallic implants were studied by post-operative MRI from the site of removal of implants. A grading scale of 0-3 was assigned for artifact in MR images whereby 0 was considered no artifact; and I-III were considered mild, moderate, and severe metallic artifacts, respectively. These grading records were correlated with other variables including the type, size, number, and composition of metallic devices; and the site and duration of orthopedic devices stay in the body. Metallic susceptibly artifacts were detected in MRI of 18 of 40 cases (45%). Screws and pins in removed hardware were the most important factors for causing artifacts in MRI. The artifacts were found more frequently in the patients who had more screws and pins in the removed implants. Gender, age, site of implantation of the device, length of the hardware, composition of the metallic implants (stainless steel versus titanium), and duration of implantation of the hardware exerted no effect in producing metallic artifacts after removal of implants. Short TE sequences of MRI (such as T1 weighted) showed fewer artifacts. Susceptibility of metallic artifacts is a frequent phenomenon in MRI of patients upon removal of metallic orthopedic implants. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Accessing Cultural Artifacts Through Digital Companions

    DEFF Research Database (Denmark)

    Rehm, Matthias; Jensen, Martin Lynge

    2015-01-01

    This paper presents a study that explores how the introduction of a digital companion agent for a museum exploration game changes children’s engagement with the presented artworks. To this end, a mobile application was developed featuring a monster agent that has eaten the artworks, which...... the children had now to find in the museum. Results show that in comparison to the paper-based version of the exploration game, children engaged in more interactions with the actual cultural artifacts and showed a significantly higher retention rate for details of the involved artworks....

  20. A holographic color camera for recording artifacts

    International Nuclear Information System (INIS)

    Jith, Abhay

    2013-01-01

    Advent of 3D televisions has created a new wave of public interest in images with depth. Though these technologies create moving pictures with apparent depth, it lacks the visual appeal and a set of other positive aspects of color holographic images. The above new wave of interest in 3D will definitely help to fuel popularity of holograms. In view of this, a low cost and handy color holography camera is designed for recording color holograms of artifacts. It is believed that such cameras will help to record medium format color holograms outside conventional holography laboratories and to popularize color holography. The paper discusses the design and the results obtained.

  1. Detection of artifacts from high energy bursts in neonatal EEG.

    Science.gov (United States)

    Bhattacharyya, Sourya; Biswas, Arunava; Mukherjee, Jayanta; Majumdar, Arun Kumar; Majumdar, Bandana; Mukherjee, Suchandra; Singh, Arun Kumar

    2013-11-01

    Detection of non-cerebral activities or artifacts, intermixed within the background EEG, is essential to discard them from subsequent pattern analysis. The problem is much harder in neonatal EEG, where the background EEG contains spikes, waves, and rapid fluctuations in amplitude and frequency. Existing artifact detection methods are mostly limited to detect only a subset of artifacts such as ocular, muscle or power line artifacts. Few methods integrate different modules, each for detection of one specific category of artifact. Furthermore, most of the reference approaches are implemented and tested on adult EEG recordings. Direct application of those methods on neonatal EEG causes performance deterioration, due to greater pattern variation and inherent complexity. A method for detection of a wide range of artifact categories in neonatal EEG is thus required. At the same time, the method should be specific enough to preserve the background EEG information. The current study describes a feature based classification approach to detect both repetitive (generated from ECG, EMG, pulse, respiration, etc.) and transient (generated from eye blinking, eye movement, patient movement, etc.) artifacts. It focuses on artifact detection within high energy burst patterns, instead of detecting artifacts within the complete background EEG with wide pattern variation. The objective is to find true burst patterns, which can later be used to identify the Burst-Suppression (BS) pattern, which is commonly observed during newborn seizure. Such selective artifact detection is proven to be more sensitive to artifacts and specific to bursts, compared to the existing artifact detection approaches applied on the complete background EEG. Several time domain, frequency domain, statistical features, and features generated by wavelet decomposition are analyzed to model the proposed bi-classification between burst and artifact segments. A feature selection method is also applied to select the

  2. Auditory steady state responses and cochlear implants: Modeling the artifact-response mixture in the perspective of denoising.

    Science.gov (United States)

    Mina, Faten; Attina, Virginie; Duroc, Yvan; Veuillet, Evelyne; Truy, Eric; Thai-Van, Hung

    2017-01-01

    Auditory steady state responses (ASSRs) in cochlear implant (CI) patients are contaminated by the spread of a continuous CI electrical stimulation artifact. The aim of this work was to model the electrophysiological mixture of the CI artifact and the corresponding evoked potentials on scalp electrodes in order to evaluate the performance of denoising algorithms in eliminating the CI artifact in a controlled environment. The basis of the proposed computational framework is a neural mass model representing the nodes of the auditory pathways. Six main contributors to auditory evoked potentials from the cochlear level and up to the auditory cortex were taken into consideration. The simulated dynamics were then projected into a 3-layer realistic head model. 32-channel scalp recordings of the CI artifact-response were then generated by solving the electromagnetic forward problem. As an application, the framework's simulated 32-channel datasets were used to compare the performance of 4 commonly used Independent Component Analysis (ICA) algorithms: infomax, extended infomax, jade and fastICA in eliminating the CI artifact. As expected, two major components were detectable in the simulated datasets, a low frequency component at the modulation frequency and a pulsatile high frequency component related to the stimulation frequency. The first can be attributed to the phase-locked ASSR and the second to the stimulation artifact. Among the ICA algorithms tested, simulations showed that infomax was the most efficient and reliable in denoising the CI artifact-response mixture. Denoising algorithms can induce undesirable deformation of the signal of interest in real CI patient recordings. The proposed framework is a valuable tool for evaluating these algorithms in a controllable environment ahead of experimental or clinical applications.

  3. Auditory steady state responses and cochlear implants: Modeling the artifact-response mixture in the perspective of denoising.

    Directory of Open Access Journals (Sweden)

    Faten Mina

    Full Text Available Auditory steady state responses (ASSRs in cochlear implant (CI patients are contaminated by the spread of a continuous CI electrical stimulation artifact. The aim of this work was to model the electrophysiological mixture of the CI artifact and the corresponding evoked potentials on scalp electrodes in order to evaluate the performance of denoising algorithms in eliminating the CI artifact in a controlled environment. The basis of the proposed computational framework is a neural mass model representing the nodes of the auditory pathways. Six main contributors to auditory evoked potentials from the cochlear level and up to the auditory cortex were taken into consideration. The simulated dynamics were then projected into a 3-layer realistic head model. 32-channel scalp recordings of the CI artifact-response were then generated by solving the electromagnetic forward problem. As an application, the framework's simulated 32-channel datasets were used to compare the performance of 4 commonly used Independent Component Analysis (ICA algorithms: infomax, extended infomax, jade and fastICA in eliminating the CI artifact. As expected, two major components were detectable in the simulated datasets, a low frequency component at the modulation frequency and a pulsatile high frequency component related to the stimulation frequency. The first can be attributed to the phase-locked ASSR and the second to the stimulation artifact. Among the ICA algorithms tested, simulations showed that infomax was the most efficient and reliable in denoising the CI artifact-response mixture. Denoising algorithms can induce undesirable deformation of the signal of interest in real CI patient recordings. The proposed framework is a valuable tool for evaluating these algorithms in a controllable environment ahead of experimental or clinical applications.

  4. FACET – a “Flexible Artifact Correction and Evaluation Toolbox” for concurrently recorded EEG/fMRI data

    Science.gov (United States)

    2013-01-01

    Background In concurrent EEG/fMRI recordings, EEG data are impaired by the fMRI gradient artifacts which exceed the EEG signal by several orders of magnitude. While several algorithms exist to correct the EEG data, these algorithms lack the flexibility to either leave out or add new steps. The here presented open-source MATLAB toolbox FACET is a modular toolbox for the fast and flexible correction and evaluation of imaging artifacts from concurrently recorded EEG datasets. It consists of an Analysis, a Correction and an Evaluation framework allowing the user to choose from different artifact correction methods with various pre- and post-processing steps to form flexible combinations. The quality of the chosen correction approach can then be evaluated and compared to different settings. Results FACET was evaluated on a dataset provided with the FMRIB plugin for EEGLAB using two different correction approaches: Averaged Artifact Subtraction (AAS, Allen et al., NeuroImage 12(2):230–239, 2000) and the FMRI Artifact Slice Template Removal (FASTR, Niazy et al., NeuroImage 28(3):720–737, 2005). Evaluation of the obtained results were compared to the FASTR algorithm implemented in the EEGLAB plugin FMRIB. No differences were found between the FACET implementation of FASTR and the original algorithm across all gradient artifact relevant performance indices. Conclusion The FACET toolbox not only provides facilities for all three modalities: data analysis, artifact correction as well as evaluation and documentation of the results but it also offers an easily extendable framework for development and evaluation of new approaches. PMID:24206927

  5. Motion correction options in PET/MRI.

    Science.gov (United States)

    Catana, Ciprian

    2015-05-01

    Subject motion is unavoidable in clinical and research imaging studies. Breathing is the most important source of motion in whole-body PET and MRI studies, affecting not only thoracic organs but also those in the upper and even lower abdomen. The motion related to the pumping action of the heart is obviously relevant in high-resolution cardiac studies. These two sources of motion are periodic and predictable, at least to a first approximation, which means certain techniques can be used to control the motion (eg, by acquiring the data when the organ of interest is relatively at rest). Additionally, nonperiodic and unpredictable motion can also occur during the scan. One obvious limitation of methods relying on external devices (eg, respiratory bellows or the electrocardiogram signal to monitor the respiratory or cardiac cycle, respectively) to trigger or gate the data acquisition is that the complex motion of internal organs cannot be fully characterized. However, detailed information can be obtained using either the PET or MRI data (or both) allowing the more complete characterization of the motion field so that a motion model can be built. Such a model and the information derived from simple external devices can be used to minimize the effects of motion on the collected data. In the ideal case, all the events recorded during the PET scan would be used to generate a motion-free or corrected PET image. The detailed motion field can be used for this purpose by applying it to the PET data before, during, or after the image reconstruction. Integrating all these methods for motion control, characterization, and correction into a workflow that can be used for routine clinical studies is challenging but could potentially be extremely valuable given the improvement in image quality and reduction of motion-related image artifacts. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Picking Up Artifacts: Storyboarding as a Gateway to Reuse

    Science.gov (United States)

    Wahid, Shahtab; Branham, Stacy M.; Cairco, Lauren; McCrickard, D. Scott; Harrison, Steve

    Storyboarding offers designers the opportunity to illustrate a visual narrative of use. Because designers often refer to past ideas, we argue storyboards can be constructed by reusing shared artifacts. We present a study in which we explore how designers reuse artifacts consisting of images and rationale during storyboard construction. We find images can aid in accessing rationale and that connections among features aid in deciding what to reuse, creating new artifacts, and constructing. Based on requirements derived from our findings, we present a storyboarding tool, PIC-UP, to facilitate artifact sharing and reuse and evaluate its use in an exploratory study. We conclude with remarks on facilitating reuse and future work.

  7. [Contrastive analysis of artifacts produced by metal dental crowns in 3.0 T magnetic resonance imaging with six sequences].

    Science.gov (United States)

    Lan, Gao; Yunmin, Lian; Pu, Wang; Haili, Huai

    2016-06-01

    This study aimed to observe and evaluate six 3.0 T sequences of metallic artifacts produced by metal dental crowns. Dental crowns fabricated with four different materials (Co-Gr, Ni-Gr, Ti alloy and pure Ti) were evaluated. A mature crossbreed dog was used as the experimental animal, and crowns were fabricated for its upper right second premolar. Each crown was examined through head MRI (3.0 T) with six sequences, namely, T₁ weighted-imaging of spin echo (T₁W/SE), T₂ weighted-imaging of inversion recovery (T₂W/IR), T₂ star gradient echo (T₂*/GRE), T2 weighted-imaging of fast spin echo (T₂W/FSE), T₁ weighted-imaging of fluid attenuate inversion recovery (T₂W/FLAIR), and T₂ weighted-imaging of propeller (T₂W/PROP). The largest area and layers of artifacts were assessed and compared. The artifact in the T₂*/GRE sequence was significantly wider than those in the other sequences (P 0.05). T₂*/GRE exhibit the strongest influence on the artifact, whereas the five other sequences contribute equally to artifact generation.

  8. Ultrafast MR imaging with EPI of organs undergoing nonperiodic motion

    International Nuclear Information System (INIS)

    Stehling, M.K.; Ordidge, R.J.; Howseman, A.M.; Coxon, R.; Chapman, B.; Mansfield, P.

    1988-01-01

    Conventional MR imaging employing repetitive data acquisition is susceptible to motion artifacts. Gating overcomes periodic motion effects. Nonperiodic motion, as encountered in the gastronintestinal tract, cardiac arrhythmias, unsedated children, and fetal imaging, thwarts conventional MR imaging. The EPI derivatives BEST and MBEST create a complex 128 x 128-pixel image in 64 msec and 128 msec, respectively, freezing motion almost completely. Sequentially recorded gastrointestinal-tract images allow quantitative evaluation of gastric and gut motility. Cardiac morphology, movement, and blood flow patterns in valvular heart disease have been depicted during atrial fibrillation. Selected clinical results with accompanying technical details illustrate the scope of EPI as a distinctive imaging modality

  9. Impact of patient motion on myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Huang Kemin; Feng Yanlin; He Xiaohong; Wen Guanghua; Yu Fengwen; Liu Shusheng; Liu Dejun; Yuan Jianwei; Yang Ming

    2008-01-01

    Objective: It is well known that patient motion may cause artifacts in myocardial SPECT images and affect clinical diagnosis. The aim of the study was to evaluate the effects of motion on quality and semi-quantitative results of myocardial perfusion images. Methods: Six healthy volunteers un- derwent myocardial perfusion SPECT. The raw data in each case was manually shifted 1-6 frames and 1 4 pixels, respectively by using the motion correction software. The shifted raw data were then reconstructed. A semi-quantitative software was used to assess the myocardial perfusion of left ventricle. The quality and semi-quantitative results of the tomographic images reconstructed from the raw data with and without motion were compared and analyzed. SPSS 12.0 was used for data analysis. Results: There was no visible artifact and semi-quantitative difference on the data with 1 frame and (or) 1 pixel shift when compared with the original data without shift. The image artifacts became significantly deteriorated when the number of flame and (or) pixel shift was increased. In general, the image artifact of inferior and posterior wall was related to the upward shift, and that of anterior and infero-posterior wall was related to the downward shift, that of septal, anterior, infero-postefior wall and apex was related to right-ward shift, and the septal and infero-posterior wall was related to the left-ward shift. The differences along the x-axis shift were more prominent than that of the y-axis (t=2.848, P<0.01), and the differences in the downward and rightward shift were more severe than the upward and leftward shift (t=2.941, 6.598; all P<0.01), respectively. Conclusions: Image artifacts became significant when there was motion induced by manual shift of more than one flame and (or) one pixel. Different motion directions were closely related to different segments of left ventricle. (authors)

  10. An extension to artifact-free projection overlaps

    International Nuclear Information System (INIS)

    Lin, Jianyu

    2015-01-01

    Purpose: In multipinhole single photon emission computed tomography, the overlapping of projections has been used to increase sensitivity. Avoiding artifacts in the reconstructed image associated with projection overlaps (multiplexing) is a critical issue. In our previous report, two types of artifact-free projection overlaps, i.e., projection overlaps that do not lead to artifacts in the reconstructed image, were formally defined and proved, and were validated via simulations. In this work, a new proposition is introduced to extend the previously defined type-II artifact-free projection overlaps so that a broader range of artifact-free overlaps is accommodated. One practical purpose of the new extension is to design a baffle window multipinhole system with artifact-free projection overlaps. Methods: First, the extended type-II artifact-free overlap was theoretically defined and proved. The new proposition accommodates the situation where the extended type-II artifact-free projection overlaps can be produced with incorrectly reconstructed portions in the reconstructed image. Next, to validate the theory, the extended-type-II artifact-free overlaps were employed in designing the multiplexing multipinhole spiral orbit imaging systems with a baffle window. Numerical validations were performed via simulations, where the corresponding 1-pinhole nonmultiplexing reconstruction results were used as the benchmark for artifact-free reconstructions. The mean square error (MSE) was the metric used for comparisons of noise-free reconstructed images. Noisy reconstructions were also performed as part of the validations. Results: Simulation results show that for noise-free reconstructions, the MSEs of the reconstructed images of the artifact-free multiplexing systems are very similar to those of the corresponding 1-pinhole systems. No artifacts were observed in the reconstructed images. Therefore, the testing results for artifact-free multiplexing systems designed using the

  11. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  12. Prior-based artifact correction (PBAC) in computed tomography

    International Nuclear Information System (INIS)

    Heußer, Thorsten; Brehm, Marcus; Ritschl, Ludwig; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data

  13. Aggregated particles caused by instrument artifact

    Science.gov (United States)

    Pierce, Ashley M.; Loría-Salazar, S. Marcela; Arnott, W. Patrick; Edwards, Grant C.; Miller, Matthieu B.; Gustin, Mae S.

    2018-04-01

    Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may pass through inlets designed to remove particles 2.5 µm in aerodynamic diameter were collected on 36 out of 158 sample days. On preliminary analysis, it was thought that these aggregated particles were superaggregates, depositing past PM10 (particles wind speeds, as well as the use of generators on site. Samples with aggregated particles, referred to as aggregates, were analyzed using a scanning electron microscope for size and shape and energy dispersive X-ray spectroscopy was used for elemental analysis. It was determined, based on the high amounts of aluminum present in the aggregate samples, that a sampling artifact associated with the sample inlet and prolonged, high wind events was the probable reason for the observed aggregates.

  14. Medical image of the week: polysomnogram artifact

    Directory of Open Access Journals (Sweden)

    Bartell J

    2015-02-01

    Full Text Available A 54 year-old man with a past medical history of attention deficit hyperactivity disorder (ADHD, low back pain, and paroxysmal supraventricular tachycardia presented to the sleep laboratory for evaluation of sleep disordered breathing. Pertinent medications include fluoxetine, ambien, and clonazepam. His Epworth sleepiness score was 18. He had a total sleep time of 12 min. On the night of his sleep study, the patient was restless and repeatedly changed positions in bed. Figures 1 and 2 show the artifact determined to be lead displacement of O1M2 after the patient shifted in bed, inadvertently removing one of his scalp electrodes. The sine waves are 60 Hz in frequency. Once the problem was identified, the lead was quickly replaced to its proper position.

  15. Persuasion through artifacts: Sociological and psychological dimensions

    Directory of Open Access Journals (Sweden)

    Stroe Mihaela

    2015-01-01

    Full Text Available Research suggests that applicants use various impression management tactics during employment interviews to influence interviewers' evaluations of their performance. Yet, little research has examined inteviewers/perceptions of applicant's impression management and their degree of nonverbal influence. This PhD study examines these questions, using both quantitative and qualitative data: Do interviewers accurately perceive applicant's impression management tactics? How are these perceptions integrated into their evaluations of applicant's nonverbal behaviour? Is perception accuracy influenced by artifacts (professional clothing that interviewees wear? It has cross-cultural design, because describes the differences in European Commission interviewers' social perceptions and Romanian human resources managers on one hand, and between social perceptions of European Commission public servants and Romanian employees on the other hand, concerning 12 key concepts: persuasion, first impressions, professional image, credibility, authenticity, competence, self- confidence, self-management, self-presentation, self-promotion, impression management tactics, professional appearance.

  16. Aggregated particles caused by instrument artifact

    Directory of Open Access Journals (Sweden)

    A. M. Pierce

    2018-04-01

    Full Text Available Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may pass through inlets designed to remove particles  <  2.5 µm in aerodynamic diameter (PM2.5. Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, aggregated particles  >  2.5 µm in aerodynamic diameter were collected on 36 out of 158 sample days. On preliminary analysis, it was thought that these aggregated particles were superaggregates, depositing past PM10 (particles  <  10 µm in aerodynamic diameter pre-impactors and PM2.5 cyclones. However, further analysis revealed that these aggregated particles were dissimilar to superaggregates observed in previous studies, both in morphology and in elemental composition. To determine if the aggregated particles were superaggregates or an instrument artifact, samples were investigated for the presence of certain elements, the occurrence of fires, high relative humidity and wind speeds, as well as the use of generators on site. Samples with aggregated particles, referred to as aggregates, were analyzed using a scanning electron microscope for size and shape and energy dispersive X-ray spectroscopy was used for elemental analysis. It was determined, based on the high amounts of aluminum present in the aggregate samples, that a sampling artifact associated with the sample inlet and prolonged, high wind events was the probable reason for the observed aggregates.

  17. Parametric modelling of nonstationary platform deck motions

    Digital Repository Service at National Institute of Oceanography (India)

    Mandal, S.

    with fast Fourier transform spectra and show good agreement. However, the higher order maximum entropy model can be used for better representation of nonstationary motions. This method also reduces long time series of nonstationary offshore data into a few...

  18. Removal of EMG and ECG artifacts from EEG based on wavelet transform and ICA.

    Science.gov (United States)

    Zhou, Weidong; Gotman, Jean

    2004-01-01

    In this study, the methods of wavelet threshold de-noising and independent component analysis (ICA) are introduced. ICA is a novel signal processing technique based on high order statistics, and is used to separate independent components from measurements. The extended ICA algorithm does not need to calculate the higher order statistics, converges fast, and can be used to separate subGaussian and superGaussian sources. A pre-whitening procedure is performed to de-correlate the mixed signals before extracting sources. The experimental results indicate the electromyogram (EMG) and electrocardiograph (ECG) artifacts in electroencephalograph (EEG) can be removed by a combination of wavelet threshold de-noising and ICA.

  19. On Lifecycle Constraints of Artifact-Centric Workflows

    Science.gov (United States)

    Kucukoguz, Esra; Su, Jianwen

    Data plays a fundamental role in modeling and management of business processes and workflows. Among the recent "data-aware" workflow models, artifact-centric models are particularly interesting. (Business) artifacts are the key data entities that are used in workflows and can reflect both the business logic and the execution states of a running workflow. The notion of artifacts succinctly captures the fluidity aspect of data during workflow executions. However, much of the technical dimension concerning artifacts in workflows is not well understood. In this paper, we study a key concept of an artifact "lifecycle". In particular, we allow declarative specifications/constraints of artifact lifecycle in the spirit of DecSerFlow, and formulate the notion of lifecycle as the set of all possible paths an artifact can navigate through. We investigate two technical problems: (Compliance) does a given workflow (schema) contain only lifecycle allowed by a constraint? And (automated construction) from a given lifecycle specification (constraint), is it possible to construct a "compliant" workflow? The study is based on a new formal variant of artifact-centric workflow model called "ArtiNets" and two classes of lifecycle constraints named "regular" and "counting" constraints. We present a range of technical results concerning compliance and automated construction, including: (1) compliance is decidable when workflow is atomic or constraints are regular, (2) for each constraint, we can always construct a workflow that satisfies the constraint, and (3) sufficient conditions where atomic workflows can be constructed.

  20. Contrast artifacts in tapping tip atomic force microscopy

    DEFF Research Database (Denmark)

    Kyhle, Anders; Sørensen, Alexis Hammer; Zandbergen, Julie Bjerring

    1998-01-01

    When recording images with an atomic force microscope using the resonant vibrating cantilever mode, surprising strange results are often achieved. Typical artifacts are strange contours, unexpected height shifts, and sudden changes of the apparent resolution in the acquired images. Such artifacts...

  1. How Do Artifact Models Help Direct SPI Projects?

    DEFF Research Database (Denmark)

    Kuhrmann, Marco; Richardson, Ita

    2015-01-01

    To overcome shortcomings associated with software process improvement (SPI), we previously recommended that process engineers focus on the artifacts to be developed in SPI projects. These artifacts should define desired outcomes, rather than specific methods. During this prior research, we develo...

  2. Metal and calcification artifact reduction for digital breast tomosynthesis

    Science.gov (United States)

    Wicklein, Julia; Jerebko, Anna; Ritschl, Ludwig; Mertelmeier, Thomas

    2017-03-01

    Tomosynthesis images of the breast suffer from artifacts caused by the presence of highly absorbing materials. These can be either induced by metal objects like needles or clips inserted during biopsy devices, or larger calcifications inside the examined breast. Mainly two different kinds of artifacts appear after the filtered backprojection procedure. The first type is undershooting artifacts near edges of high-contrast objects caused by the filtering step. The second type is out-of-plane (ripple) artifacts that appear even in slices where the metal object or macrocalcifications does not exist. Due to the limited angular range of tomosynthesis systems, overlapping structures have high influence on neighboring regions. To overcome these problems, a segmentation of artifact introducing objects is performed on the projection images. Both projection versions, with and without high-contrast objects are filtered independently to avoid undershootings. During backprojection a decision is made for each reconstructed voxel, if it is artifact or high-contrast object. This is based on a mask image, gained from the segmentation of high-contrast objects. This procedure avoids undershooting artifacts and additionally reduces out-of-plane ripple. Results are demonstrated for different kinds of artifact inducing objects and calcifications.

  3. Making Digital Artifacts on the Web Verifiable and Reliable

    NARCIS (Netherlands)

    Kuhn, T.; Dumontier, M.

    2015-01-01

    The current Web has no general mechanisms to make digital artifacts - such as datasets, code, texts, and images - verifiable and permanent. For digital artifacts that are supposed to be immutable, there is moreover no commonly accepted method to enforce this immutability. These shortcomings have a

  4. Incidental ferumoxytol artifacts in clinical brain MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bowser, Bruce A.; Campeau, Norbert G.; Carr, Carrie M.; Diehn, Felix E.; McDonald, Jennifer S.; Miller, Gary M.; Kaufmann, Timothy J. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2016-11-15

    Ferumoxytol (Feraheme) is a parenteral therapy approved for treatment of iron deficiency anemia. The product insert for ferumoxytol states that it may affect the diagnostic ability of MRI for up to 3 months. However, the expected effects may not be commonly recognized among clinical neuroradiologists. Our purpose is to describe the artifacts we have seen at our institution during routine clinical practice. We reviewed the patients at our institution that had brain MRI performed within 90 days of receiving intravenous ferumoxytol. The imaging was reviewed for specific findings, including diffusion-weighted imaging vascular susceptibility artifact, gradient-echo echo-planar T2*-weighted vascular susceptibility artifact, SWI/SWAN vascular susceptibility artifact, hypointense vascular signal on T2-weighted images, pre-gadolinium contrast vascular enhancement on magnetization-prepared rapid acquisition gradient echo (MPRAGE) imaging, and effects on post-gadolinium contrast T1 imaging. Multiple artifacts were observed in patients having a brain MRI within 3 days of receiving intravenous ferumoxytol. These included susceptibility artifact on DWI, GRE, and SWAN/SWI imaging, pre-gadolinium contrast increased vascular signal on MPRAGE imaging, and decreased expected enhancement on post-gadolinium contrast T1-weighted imaging. Ferumoxytol can create imaging artifacts which complicate clinical interpretation when brain MRI is performed within 3 days of administration. Recognition of the constellation of artifacts produced by ferumoxytol is important in order to obviate additional unnecessary examinations and mitigate errors in interpretation. (orig.)

  5. Quantification of Rain Induced Artifacts on Digital Satellite Television ...

    African Journals Online (AJOL)

    The presence of artifacts on the high definition television (TV) content and the eventual loss of the digital TV signals to rain is still a major concern to satellite operators, digital satellite television (DSTV) and terrestrial television content providers. In this paper, the artifacts present in a typical DSTV signal is examined on a ...

  6. Toddlers favor communicatively presented information over statistical reliability in learning about artifacts.

    Directory of Open Access Journals (Sweden)

    Hanna Marno

    Full Text Available Observed associations between events can be validated by statistical information of reliability or by testament of communicative sources. We tested whether toddlers learn from their own observation of efficiency, assessed by statistical information on reliability of interventions, or from communicatively presented demonstration, when these two potential types of evidence of validity of interventions on a novel artifact are contrasted with each other. Eighteen-month-old infants observed two adults, one operating the artifact by a method that was more efficient (2/3 probability of success than that of the other (1/3 probability of success. Compared to the Baseline condition, in which communicative signals were not employed, infants tended to choose the less reliable method to operate the artifact when this method was demonstrated in a communicative manner in the Experimental condition. This finding demonstrates that, in certain circumstances, communicative sanctioning of reliability may override statistical evidence for young learners. Such a bias can serve fast and efficient transmission of knowledge between generations.

  7. ANALYSIS OF TERRESTRIAL LASER SCANNING AND PHOTOGRAMMETRY DATA FOR DOCUMENTATION OF HISTORICAL ARTIFACTS

    Directory of Open Access Journals (Sweden)

    R. A. Kuçak

    2016-10-01

    Full Text Available Historical artifacts living from the past until today exposed to many destructions non-naturally or naturally. For this reason, The protection and documentation studies of Cultural Heritage to inform the next generations are accelerating day by day in the whole world. The preservation of historical artifacts using advanced 3D measurement technologies becomes an efficient tool for mapping solutions. There are many methods for documentation and restoration of historic structures. In addition to traditional methods such as simple hand measurement and tachometry, terrestrial laser scanning is rapidly becoming one of the most commonly used techniques due to its completeness, accuracy and fastness characteristics. This study evaluates terrestrial laser scanning(TLS technology and photogrammetry for documenting the historical artifacts facade data in 3D Environment. PhotoModeler software developed by Eos System was preferred for Photogrammetric method. Leica HDS 6000 laser scanner developed by Leica Geosystems and Cyclone software which is the laser data evaluation software belonging to the company is preferred for Terrestrial Laser Scanning method. Taking into account the results obtained with this software product is intended to provide a contribution to the studies for the documentation of cultural heritage.

  8. Distributed Cognition and Distributed Morality: Agency, Artifacts and Systems.

    Science.gov (United States)

    Heersmink, Richard

    2017-04-01

    There are various philosophical approaches and theories describing the intimate relation people have to artifacts. In this paper, I explore the relation between two such theories, namely distributed cognition and distributed morality theory. I point out a number of similarities and differences in these views regarding the ontological status they attribute to artifacts and the larger systems they are part of. Having evaluated and compared these views, I continue by focussing on the way cognitive artifacts are used in moral practice. I specifically conceptualise how such artifacts (a) scaffold and extend moral reasoning and decision-making processes, (b) have a certain moral status which is contingent on their cognitive status, and (c) whether responsibility can be attributed to distributed systems. This paper is primarily written for those interested in the intersection of cognitive and moral theory as it relates to artifacts, but also for those independently interested in philosophical debates in extended and distributed cognition and ethics of (cognitive) technology.

  9. Inter-slice motion correction using spatiotemporal interpolation for functional magnetic resonance imaging of the moving fetus

    OpenAIRE

    Limperopoulos, Catherine; You, Wonsang

    2017-01-01

    Fetal motion continues to be one of the major artifacts in in-utero functional MRI; interestingly few methods have been developed to address fetal motion correction. In this study, we propose a robust method for motion correction in fetal fMRI by which both inter-slice and inter-volume motion artifacts are jointly corrected. To accomplish this, an original volume is temporally split into odd and even slices, and then voxel intensities are spatially and temporally interpolated in the process o...

  10. Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Azcona, Juan Diego; Li, Ruijiang; Mok, Edward; Hancock, Steven; Xing, Lei

    2013-01-01

    Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators

  11. Magnetic resonance imaging of metal artifact reduction sequences in the assessment of metal-on-metal hip prostheses

    Directory of Open Access Journals (Sweden)

    Aboelmagd SM

    2014-05-01

    Full Text Available Sharief M Aboelmagd, Paul N Malcolm, Andoni P Toms Department of Radiology, Norfolk and Norwich University Hospital National Health Service Trust, Norwich, UK Abstract: Recent developments in metal artifact reduction techniques in magnetic resonance (MR have, in large part, been stimulated by the advent of soft tissue complications associated with modern metal-on-metal total hip replacements. Metallic orthopedic implants can result in severe degradation of MR images because ferromagnetic susceptibility causes signal loss, signal pile-up, geometric distortion, and failure of fat suppression. There are several approaches to controlling these susceptibility artifacts. Standard fast spin echo sequences can be adapted by modifying echo times, matrix, receiver bandwidth, slice thickness, and echo trains to minimize frequency encoding misregistration. Short tau inversion recovery and 2-point Dixon techniques are both more resistant to susceptibility artifacts than spectral fat suppression. A number of dedicated metal artifact reduction sequences are now available commercially. The common approach of these multispectral techniques is to generate three dimensional datasets from which the final images are reconstructed. Frequency encoding misregistration is controlled using a variety of techniques, including specific resonant frequency acquisition, view-angle tilting, and phase encoding. Metal artifact reduction MR imaging has been the key to understanding the prevalence, severity, and prognosis of adverse reactions to metal debris in metal-on-metal hip replacements. Conventional radiographs are typically normal or demonstrate minimal change and are unable to demonstrate the often extensive soft tissue abnormalities, which include necrosis, soft tissue masses and fluid collections, myositis, muscle atrophy, tendon avulsions, and osteonecrosis. These MR findings correlate poorly with clinical and serological measures of disease, and therefore MR imaging is

  12. Adiabatic Low-Pass J Filters for Artifact Suppression in Heteronuclear NMR

    DEFF Research Database (Denmark)

    Meier, Sebastian; Benie, Andrew J; Duus, Jens Øllgaard

    2009-01-01

    NMR artifact purging: Modern NMR experiments depend on efficient coherence transfer pathways for their sensitivity and on suppression of undesired pathways leading to artifacts for their spectral clarity. A novel robust adiabatic element suppresses hard-to-get-at artifacts....

  13. Searching for alien artifacts on the moon

    Science.gov (United States)

    Davies, P. C. W.; Wagner, R. V.

    2013-08-01

    The Search for Extraterrestrial Intelligence (SETI) has a low probability of success, but it would have a high impact if successful. Therefore it makes sense to widen the search as much as possible within the confines of the modest budget and limited resources currently available. To date, SETI has been dominated by the paradigm of seeking deliberately beamed radio messages. However, indirect evidence for extraterrestrial intelligence could come from any incontrovertible signatures of non-human technology. Existing searchable databases from astronomy, biology, earth and planetary sciences all offer low-cost opportunities to seek a footprint of extraterrestrial technology. In this paper we take as a case study one particular new and rapidly-expanding database: the photographic mapping of the Moon's surface by the Lunar Reconnaissance Orbiter (LRO) to 0.5 m resolution. Although there is only a tiny probability that alien technology would have left traces on the moon in the form of an artifact or surface modification of lunar features, this location has the virtue of being close, and of preserving traces for an immense duration. Systematic scrutiny of the LRO photographic images is being routinely conducted anyway for planetary science purposes, and this program could readily be expanded and outsourced at little extra cost to accommodate SETI goals, after the fashion of the SETI@home and Galaxy Zoo projects.

  14. Colorectal Cancer "Methylator Phenotype": Fact or Artifact?

    Directory of Open Access Journals (Sweden)

    Charles Anacleto

    2005-04-01

    Full Text Available It has been proposed that human colorectal tumors can be classified into two groups: one in which methylation is rare, and another with methylation of several loci associated with a "CpG island methylated phenotype (CIMP," characterized by preferential proximal location in the colon, but otherwise poorly defined. There is considerable overlap between this putative methylator phenotype and the well-known mutator phenotype associated with microsatellite instability (MSI. We have examined hypermethylation of the promoter region of five genes (DAPK, MGMT, hMLH1, p16INK4a, and p14ARF in 106 primary colorectal cancers. A graph depicting the frequency of methylated loci in the series of tumors showed a continuous, monotonically decreasing distribution quite different from the previously claimed discontinuity. We observed a significant association between the presence of three or more methylated loci and the proximal location of the tumors. However, if we remove from analysis the tumors with hMLH1 methylation or those with MSI, the significance vanishes, suggesting that the association between multiple methylations and proximal location was indirect due to the correlation with MSI. Thus, our data do not support the independent existence of the so-called methylator phenotype and suggest that it rather may represent a statistical artifact caused by confounding of associations.

  15. A Combined Methodology to Eliminate Artifacts in Multichannel Electrogastrogram Based on Independent Component Analysis and Ensemble Empirical Mode Decomposition.

    Science.gov (United States)

    Sengottuvel, S; Khan, Pathan Fayaz; Mariyappa, N; Patel, Rajesh; Saipriya, S; Gireesan, K

    2018-06-01

    Cutaneous measurements of electrogastrogram (EGG) signals are heavily contaminated by artifacts due to cardiac activity, breathing, motion artifacts, and electrode drifts whose effective elimination remains an open problem. A common methodology is proposed by combining independent component analysis (ICA) and ensemble empirical mode decomposition (EEMD) to denoise gastric slow-wave signals in multichannel EGG data. Sixteen electrodes are fixed over the upper abdomen to measure the EGG signals under three gastric conditions, namely, preprandial, postprandial immediately, and postprandial 2 h after food for three healthy subjects and a subject with a gastric disorder. Instantaneous frequencies of intrinsic mode functions that are obtained by applying the EEMD technique are analyzed to individually identify and remove each of the artifacts. A critical investigation on the proposed ICA-EEMD method reveals its ability to provide a higher attenuation of artifacts and lower distortion than those obtained by the ICA-EMD method and conventional techniques, like bandpass and adaptive filtering. Characteristic changes in the slow-wave frequencies across the three gastric conditions could be determined from the denoised signals for all the cases. The results therefore encourage the use of the EEMD-based technique for denoising gastric signals to be used in clinical practice.

  16. Physiological artifacts in scalp EEG and ear-EEG.

    Science.gov (United States)

    Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben

    2017-08-11

    A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.

  17. Grain-boundary, glassy-phase identification and possible artifacts

    International Nuclear Information System (INIS)

    Simpson, Y.K.; Carter, C.B.; Sklad, P.; Bentley, J.

    1985-01-01

    Specimen artifacts such as grain boundary grooving, surface damage of the specimen, and Si contamination are shown experimentally to arise from the ion milling used in the preparation of transmission electron microscopy specimens. These artifacts in polycrystalline, ceramic specimens can cause clean grain boundaries to appear to contain a glassy phase when the dark-field diffuse scattering technique, the Fresnel fringe technique, and analytical electron microscopy (energy dispersive spectroscopy) are used to identify glassy phases at a grain boundary. The ambiguity in interpreting each of these techniques due to the ion milling artifacts will be discussed from a theoretical view point and compared to experimental results obtained for alumina

  18. Towards a concept of community artifact ecology in HCI?

    DEFF Research Database (Denmark)

    Saad-Sulonen, Joanna; Korsgaard, Henrik

    or workplaces do. This has implications on understanding how to research and design HCI for communities but also on refining the ecological perspective in HCI. We look in particular at examples from preliminary research on a local self-organised urban community and discuss what existing concepts in the ecology......In this paper we introduce the concept of community artifact ecology. We argue that taking a community perspective on the concept of artifact ecologies is relevant in HCI because communities are also dealing with multitudes of artifacts, in ways di↵erent that individuals, organizations...

  19. Thermoluminescent determination of prehistoric heat treatment of chert artifacts

    International Nuclear Information System (INIS)

    Melcher, C.L.; Zimmerman, D.W.

    1977-01-01

    In recent years archeologists have become interested in the extent to which prehistoric peoples heat-treated chert prior to shaping it into tools. Thermoluminescent determination of the radiation dose accumulated by an artifact since it was formed or last heated provides a simple, reliable test for such heat treatment. This test can be applied to single artifacts without the need for raw source material for comparison. Results on 25 artifacts from four sites indicate that, for many chert sources, color and luster are not useful indicators of heat treatment by prehistoric peoples

  20. Artifacts Affecting Musculoskeletal Magnetic Resonance Imaging: Their Origins and Solutions.

    Science.gov (United States)

    Roth, Eira; Hoff, Michael; Richardson, Michael L; Ha, Alice S; Porrino, Jack

    2016-01-01

    Among articles within the radiology literature, few present the manifestations of magnetic resonance imaging artifacts in a clinically oriented manner. Recognizing such artifacts is imperative given the increasing clinical use of magnetic resonance imaging and the emphasis by the American Board of Radiology on practical physics applications. The purpose of this article is to present magnetic resonance physics principles visually and conceptually in the context of common musculoskeletal radiology artifacts and their solutions, described using nonmathematical explanations. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Artifact in Pediatric Oculomotor Findings during Videonystagmography: A Retrospective Analysis.

    Science.gov (United States)

    Doettl, Steven M; Plyler, Patrick N; McCaslin, Devin L

    2017-04-01

    Accurate measurement of oculomotor function using videonystagmography (VNG) is imperative for diagnosis and management of patients with reported dizziness. The oculomotor evaluation during VNG utilizes video-oculography providing valuable information regarding the central structures and pathways that control eye movements. Artifact may have an effect on the overall validity and reliability of VNG oculomotor tracings and can result from patient and/or recording errors. It is postulated that artifact could occur more frequently in the pediatric population due to both patient and equipment factors. The purpose of this study was to systematically evaluate the occurrence and impact of artifact on saccades, smooth pursuit, and optokinetic (OPK) testing in normal pediatric and adult subjects using commercially available clinical VNG equipment and standard clinical protocols for oculomotor testing. The present study utilized a retrospective analysis of a repeated measures design. Oculomotor results from a total of 62 participants were analyzed. Portions of these data have been presented in a previous research study. Group 1 consisted of twenty-nine 4- to 6-yr-olds with an average age of 4.86 (SD = 0.88) yr. Group 2 consisted of thirty-three 22- to 44-yr-olds with an average age of 25.2 (SD = 5.34) yr. Raw oculomotor recordings were analyzed "offline" by a single masked, trained investigator. Each tracing was evaluated for instances of artifact including eye blinks, eye closure, eyes moving in opposite direction of the target, eye tracking software problems, and overall poor morphology. The number of instances of artifact were noted and recorded for each participant in both groups. Individual eye movements not affected by artifact were included for final analysis. Artifact rejection techniques were also compared. The results indicated increased artifact for the pediatric group for saccade and smooth pursuit testing. Additionally, a significant decrease in instances of

  2. Applications of Phase-Based Motion Processing

    Science.gov (United States)

    Branch, Nicholas A.; Stewart, Eric C.

    2018-01-01

    Image pyramids provide useful information in determining structural response at low cost using commercially available cameras. The current effort applies previous work on the complex steerable pyramid to analyze and identify imperceptible linear motions in video. Instead of implicitly computing motion spectra through phase analysis of the complex steerable pyramid and magnifying the associated motions, instead present a visual technique and the necessary software to display the phase changes of high frequency signals within video. The present technique quickly identifies regions of largest motion within a video with a single phase visualization and without the artifacts of motion magnification, but requires use of the computationally intensive Fourier transform. While Riesz pyramids present an alternative to the computationally intensive complex steerable pyramid for motion magnification, the Riesz formulation contains significant noise, and motion magnification still presents large amounts of data that cannot be quickly assessed by the human eye. Thus, user-friendly software is presented for quickly identifying structural response through optical flow and phase visualization in both Python and MATLAB.

  3. WE-G-17A-03: MRIgRT: Quantification of Organ Motion

    International Nuclear Information System (INIS)

    Stanescu, T; Tadic, T; Jaffray, D

    2014-01-01

    Purpose: To develop an MRI-based methodology and tools required for the quantification of organ motion on a dedicated MRI-guided radiotherapy system. A three-room facility, consisting of a TrueBeam 6X linac vault, a 1.5T MR suite and a brachytherapy interventional room, is currently under commissioning at our institution. The MR scanner can move and image in either room for diagnostic and treatment guidance purposes. Methods: A multi-imaging modality (MR, kV) phantom, featuring programmable 3D simple and complex motion trajectories, was used for the validation of several image sorting algorithms. The testing was performed on MRI (e.g. TrueFISP, TurboFLASH), 4D CT and 4D CBCT. The image sorting techniques were based on a) direct image pixel manipulation into columns or rows, b) single and aggregated pixel data tracking and c) using computer vision techniques for global pixel analysis. Subsequently, the motion phantom and sorting algorithms were utilized for commissioning of MR fast imaging techniques for 2D-cine and 4D data rendering. MR imaging protocols were optimized (e.g. readout gradient strength vs. SNR) to minimize the presence of susceptibility-induced distortions, which were reported through phantom experiments and numerical simulations. The system-related distortions were also quantified (dedicated field phantom) and treated as systematic shifts where relevant. Results: Image sorting algorithms were validated for specific MR-based applications such as quantification of organ motion, local data sampling, and 4D MRI for pre-RT delivery with accuracy better than the raw image pixel size (e.g. 1 mm). MR fast imaging sequences were commissioning and imaging strategies were developed to mitigate spatial artifacts with minimal penalty on the image spatial and temporal sampling. Workflows (e.g. liver) were optimized to include the new motion quantification tools for RT planning and daily patient setup verification. Conclusion: Comprehensive methods were developed

  4. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  5. The fast code

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, L.N.; Wilson, R.E. [Oregon State Univ., Dept. of Mechanical Engineering, Corvallis, OR (United States)

    1996-09-01

    The FAST Code which is capable of determining structural loads on a flexible, teetering, horizontal axis wind turbine is described and comparisons of calculated loads with test data are given at two wind speeds for the ESI-80. The FAST Code models a two-bladed HAWT with degrees of freedom for blade bending, teeter, drive train flexibility, yaw, and windwise and crosswind tower motion. The code allows blade dimensions, stiffnesses, and weights to differ and models tower shadow, wind shear, and turbulence. Additionally, dynamic stall is included as are delta-3 and an underslung rotor. Load comparisons are made with ESI-80 test data in the form of power spectral density, rainflow counting, occurrence histograms, and azimuth averaged bin plots. It is concluded that agreement between the FAST Code and test results is good. (au)

  6. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  7. Feasibility of Stereo-Infrared Tracking to Monitor Patient Motion During Cardiac SPECT Imaging

    OpenAIRE

    Beach, Richard D.; Pretorius, P. Hendrik; Boening, Guido; Bruyant, Philippe P.; Feng, Bing; Fulton, Roger R.; Gennert, Michael A.; Nadella, Suman; King, Michael A.

    2004-01-01

    Patient motion during cardiac SPECT imaging can cause diagnostic imaging artifacts. We investigated the feasibility of monitoring patient motion using the Polaris motion-tracking system. This system uses passive infrared reflection from small spheres to provide real-time position data with vendor stated 0.35 mm accuracy and 0.2 mm repeatability. In our configuration, the Polaris system views through the SPECT gantry toward the patient's head. List-mode event data was temporally synchronized w...

  8. Timing and related artifacts in multidimensional NMR

    International Nuclear Information System (INIS)

    Marion, Dominique

    2012-01-01

    The information content of multidimensional NMR spectra is limited by the presence of several kinds of artifacts that originate from incorrect timing of evolution periods. The objective of this review is to provide tools for successful implementation of published pulse sequences, in which timing and pulse compensations are often implicit. We will analyze the constraints set by the use of Fourier transformation, the spin precession during rectangular or shaped pulses, the Bloch-Siegert effects due to pulse on other spins and the delay introduced by the filters for the acquisition dimension. A frequency dependent phase correction or an incorrect scaling of the first data point leads to baseline offsets or curvature due to the properties of the Fourier transform. Because any r.f. pulse has a finite length, chemical shift is always active during excitation, flip-back, inversion, and refocusing pulses. Rectangular or selective shaped pulses can be split into three periods: an ideal rotation surrounded by two chemical shift evolution periods, which should be subtracted from the adjacent delays to avoid linear phase correction. Bloch-Siegert effects originate from irradiation at frequencies near those observed in the spectrum and can lead to phase or frequency shifts. They can be minimized by simultaneous irradiation on both sides of the observed spins. In terms of timing, the very end of the pulse sequence the acquisition behaves differently since the data are filtered by either analog or digital means. This additional delay is filter and spectrometer specific and should be tuned to minimize the required phase correction. Combined together, all these adjustments lead to perfectly phased spectra with flat baseline and no peak shifts or distortion. (author)

  9. Artifacts in Radar Imaging of Moving Targets

    Science.gov (United States)

    2012-09-01

    CA, USA, 2007. [11] B. Borden, Radar imaging of airborne targets: A primer for Applied mathematicians and Physicists . New York, NY: Taylor and... Project (0704–0188) Washington DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE 21 September 2012 3. REPORT TYPE AND DATES COVERED...CW Continuous Wave DAC Digital to Analog Convertor DFT Discrete Fourier Transform FBP Filtered Back Projection FFT Fast Fourier Transform GPS

  10. Cultural Artifact Detection in Long Wave Infrared Imagery.

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dylan Zachary [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Craven, Julia M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ramon, Eric [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-01-01

    Detection of cultural artifacts from airborne remotely sensed data is an important task in the context of on-site inspections. Airborne artifact detection can reduce the size of the search area the ground based inspection team must visit, thereby improving the efficiency of the inspection process. This report details two algorithms for detection of cultural artifacts in aerial long wave infrared imagery. The first algorithm creates an explicit model for cultural artifacts, and finds data that fits the model. The second algorithm creates a model of the background and finds data that does not fit the model. Both algorithms are applied to orthomosaic imagery generated as part of the MSFE13 data collection campaign under the spectral technology evaluation project.

  11. Ring artifact correction for high-resolution micro CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Prell, Daniel; Kalender, Willi A

    2009-01-01

    In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis. (note)

  12. Adaptive noise canceling of electrocardiogram artifacts in single channel electroencephalogram.

    Science.gov (United States)

    Cho, Sung Pil; Song, Mi Hye; Park, Young Cheol; Choi, Ho Seon; Lee, Kyoung Joung

    2007-01-01

    A new method for estimating and eliminating electrocardiogram (ECG) artifacts from single channel scalp electroencephalogram (EEG) is proposed. The proposed method consists of emphasis of QRS complex from EEG using least squares acceleration (LSA) filter, generation of synchronized pulse with R-peak and ECG artifacts estimation and elimination using adaptive filter. The performance of the proposed method was evaluated using simulated and real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, which are independent component analysis (ICA) and ensemble average (EA) method. From this we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifacts from single channel EEG and simple to use for ambulatory/portable EEG monitoring system.

  13. quantification of rain quantification of rain induced artifacts on digital

    African Journals Online (AJOL)

    eobe

    DSTV) ... satellite television, rain attenuation, digital artifacts, pixelation, rainfall rate. 1. ... screen and blocking are commonly observed in .... The precipitation data was collected using a self- ..... Networks: Comparison at Equatorial and Subtropical.

  14. Mitigation of artifacts in rtm with migration kernel decomposition

    KAUST Repository

    Zhan, Ge

    2012-01-01

    The migration kernel for reverse-time migration (RTM) can be decomposed into four component kernels using Born scattering and migration theory. Each component kernel has a unique physical interpretation and can be interpreted differently. In this paper, we present a generalized diffraction-stack migration approach for reducing RTM artifacts via decomposition of migration kernel. The decomposition leads to an improved understanding of migration artifacts and, therefore, presents us with opportunities for improving the quality of RTM images.

  15. Reduction of metal artifacts: beam hardening and photon starvation effects

    Science.gov (United States)

    Yadava, Girijesh K.; Pal, Debashish; Hsieh, Jiang

    2014-03-01

    The presence of metal-artifacts in CT imaging can obscure relevant anatomy and interfere with disease diagnosis. The cause and occurrence of metal-artifacts are primarily due to beam hardening, scatter, partial volume and photon starvation; however, the contribution to the artifacts from each of them depends on the type of hardware. A comparison of CT images obtained with different metallic hardware in various applications, along with acquisition and reconstruction parameters, helps understand methods for reducing or overcoming such artifacts. In this work, a metal beam hardening correction (BHC) and a projection-completion based metal artifact reduction (MAR) algorithms were developed, and applied on phantom and clinical CT scans with various metallic implants. Stainless-steel and Titanium were used to model and correct for metal beam hardening effect. In the MAR algorithm, the corrupted projection samples are replaced by the combination of original projections and in-painted data obtained by forward projecting a prior image. The data included spine fixation screws, hip-implants, dental-filling, and body extremity fixations, covering range of clinically used metal implants. Comparison of BHC and MAR on different metallic implants was used to characterize dominant source of the artifacts, and conceivable methods to overcome those. Results of the study indicate that beam hardening could be a dominant source of artifact in many spine and extremity fixations, whereas dental and hip implants could be dominant source of photon starvation. The BHC algorithm could significantly improve image quality in CT scans with metallic screws, whereas MAR algorithm could alleviate artifacts in hip-implants and dentalfillings.

  16. Preliminary experimental insights into differential heat impact among lithic artifacts

    OpenAIRE

    Guillermo Bustos-Pérez; Javier Baena Preysler

    2016-01-01

    The presence of thermally altered and broken flint artifacts is common at archaeological sites. Most studies focus their attention on the effects of heat treatment on flint to improve knapping qualities, disregarding the effects of fire over flint under uncontrolled conditions. This paper aims to show how under uncontrolled heating processes flint artifacts develop different heat alterations (such as levels of breakage, presence of scales, etc.) as a result of vertical distribution, volume or...

  17. Cyber Event Artifact Investigation Training in a Virtual Environment

    Science.gov (United States)

    2017-12-01

    information was desired in the logs as well as best practices provided by Microsoft: 1. Every Success or Failure for: Account Logon Events, Account ...use this artifact in conjunction with information discovered through investigation of other artifacts, such as logs and accounts . For instance, the...when coupled with logs, accounts , and process data, this information may provide enough evidence for transition into the reporting and Preliminary

  18. Free-breathing black-blood CINE fast-spin echo imaging for measuring abdominal aortic wall distensibility: a feasibility study

    Science.gov (United States)

    Lin, Jyh-Miin; Patterson, Andrew J.; Chao, Tzu-Cheng; Zhu, Chengcheng; Chang, Hing-Chiu; Mendes, Jason; Chung, Hsiao-Wen; Gillard, Jonathan H.; Graves, Martin J.

    2017-05-01

    The paper reports a free-breathing black-blood CINE fast-spin echo (FSE) technique for measuring abdominal aortic wall motion. The free-breathing CINE FSE includes the following MR techniques: (1) variable-density sampling with fast iterative reconstruction; (2) inner-volume imaging; and (3) a blood-suppression preparation pulse. The proposed technique was evaluated in eight healthy subjects. The inner-volume imaging significantly reduced the intraluminal artifacts of respiratory motion (p  =  0.015). The quantitative measurements were a diameter of 16.3  ±  2.8 mm and wall distensibility of 2.0  ±  0.4 mm (12.5  ±  3.4%) and 0.7  ±  0.3 mm (4.1  ±  1.0%) for the anterior and posterior walls, respectively. The cyclic cross-sectional distensibility was 35  ±  15% greater in the systolic phase than in the diastolic phase. In conclusion, we developed a feasible CINE FSE method to measure the motion of the abdominal aortic wall, which will enable clinical scientists to study the elasticity of the abdominal aorta.

  19. Evaluation of motion and its effect on brain magnetic resonance image quality in children

    Energy Technology Data Exchange (ETDEWEB)

    Afacan, Onur; Erem, Burak; Roby, Diona P.; Prabhu, Sanjay P.; Warfield, Simon K. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Roth, Noam; Roth, Amir [Robin Medical Inc., Baltimore, MD (United States)

    2016-11-15

    Motion artifacts pose significant problems for the acquisition of MR images in pediatric populations. To evaluate temporal motion metrics in MRI scanners and their effect on image quality in pediatric populations in neuroimaging studies. We report results from a large pediatric brain imaging study that shows the effect of motion on MRI quality. We measured motion metrics in 82 pediatric patients, mean age 13.4 years, in a T1-weighted brain MRI scan. As a result of technical difficulties, 5 scans were not included in the subsequent analyses. A radiologist graded the images using a 4-point scale ranging from clinically non-diagnostic because of motion artifacts to no motion artifacts. We used these grades to correlate motion parameters such as maximum motion, mean displacement from a reference point, and motion-free time with image quality. Our results show that both motion-free time (as a ratio of total scan time) and average displacement from a position at a fixed time (when the center of k-space was acquired) were highly correlated with image quality, whereas maximum displacement was not as good a predictor. Among the 77 patients whose motion was measured successfully, 17 had average displacements of greater than 0.5 mm, and 11 of those (14.3%) resulted in non-diagnostic images. Similarly, 14 patients (18.2%) had less than 90% motion-free time, which also resulted in non-diagnostic images. We report results from a large pediatric study to show how children and young adults move in the MRI scanner and the effect that this motion has on image quality. The results will help the motion-correction community in better understanding motion patterns in pediatric populations and how these patterns affect MR image quality. (orig.)

  20. Evaluation of motion and its effect on brain magnetic resonance image quality in children

    International Nuclear Information System (INIS)

    Afacan, Onur; Erem, Burak; Roby, Diona P.; Prabhu, Sanjay P.; Warfield, Simon K.; Roth, Noam; Roth, Amir

    2016-01-01

    Motion artifacts pose significant problems for the acquisition of MR images in pediatric populations. To evaluate temporal motion metrics in MRI scanners and their effect on image quality in pediatric populations in neuroimaging studies. We report results from a large pediatric brain imaging study that shows the effect of motion on MRI quality. We measured motion metrics in 82 pediatric patients, mean age 13.4 years, in a T1-weighted brain MRI scan. As a result of technical difficulties, 5 scans were not included in the subsequent analyses. A radiologist graded the images using a 4-point scale ranging from clinically non-diagnostic because of motion artifacts to no motion artifacts. We used these grades to correlate motion parameters such as maximum motion, mean displacement from a reference point, and motion-free time with image quality. Our results show that both motion-free time (as a ratio of total scan time) and average displacement from a position at a fixed time (when the center of k-space was acquired) were highly correlated with image quality, whereas maximum displacement was not as good a predictor. Among the 77 patients whose motion was measured successfully, 17 had average displacements of greater than 0.5 mm, and 11 of those (14.3%) resulted in non-diagnostic images. Similarly, 14 patients (18.2%) had less than 90% motion-free time, which also resulted in non-diagnostic images. We report results from a large pediatric study to show how children and young adults move in the MRI scanner and the effect that this motion has on image quality. The results will help the motion-correction community in better understanding motion patterns in pediatric populations and how these patterns affect MR image quality. (orig.)

  1. A multistage motion vector processing method for motion-compensated frame interpolation.

    Science.gov (United States)

    Huang, Ai- Mei; Nguyen, Truong Q

    2008-05-01

    In this paper, a novel, low-complexity motion vector processing algorithm at the decoder is proposed for motion-compensated frame interpolation or frame rate up-conversion. We address the problems of having broken edges and deformed structures in an interpolated frame by hierarchically refining motion vectors on different block sizes. Our method explicitly considers the reliability of each received motion vector and has the capability of preserving the structure information. This is achieved by analyzing the distribution of residual energies and effectively merging blocks that have unreliable motion vectors. The motion vector reliability information is also used as a prior knowledge in motion vector refinement using a constrained vector median filter to avoid choosing identical unreliable one. We also propose using chrominance information in our method. Experimental results show that the proposed scheme has better visual quality and is also robust, even in video sequences with complex scenes and fast motion.

  2. Artifact removal from EEG signals using adaptive filters in cascade

    Science.gov (United States)

    Garcés Correa, A.; Laciar, E.; Patiño, H. D.; Valentinuzzi, M. E.

    2007-11-01

    Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three adaptive filters based on a least mean squares (LMS) algorithm is proposed. The first one eliminates line interference, the second adaptive filter removes the ECG artifacts and the last one cancels EOG spikes. Each stage uses a finite impulse response (FIR) filter, which adjusts its coefficients to produce an output similar to the artifacts present in the EEG. The proposed cascade adaptive filter was tested in five real EEG records acquired in polysomnographic studies. In all cases, line-frequency, ECG and EOG artifacts were attenuated. It is concluded that the proposed filter reduces the common artifacts present in EEG signals without removing significant information embedded in these records.

  3. Artifact removal from EEG signals using adaptive filters in cascade

    International Nuclear Information System (INIS)

    Garces Correa, A; Laciar, E; Patino, H D; Valentinuzzi, M E

    2007-01-01

    Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three adaptive filters based on a least mean squares (LMS) algorithm is proposed. The first one eliminates line interference, the second adaptive filter removes the ECG artifacts and the last one cancels EOG spikes. Each stage uses a finite impulse response (FIR) filter, which adjusts its coefficients to produce an output similar to the artifacts present in the EEG. The proposed cascade adaptive filter was tested in five real EEG records acquired in polysomnographic studies. In all cases, line-frequency, ECG and EOG artifacts were attenuated. It is concluded that the proposed filter reduces the common artifacts present in EEG signals without removing significant information embedded in these records

  4. Artifact removal from EEG signals using adaptive filters in cascade

    Energy Technology Data Exchange (ETDEWEB)

    Garces Correa, A [Gabinete de TecnologIa Medica, Facultad de Ingenieria, Universidad Nacional de San Juan (Argentina); Laciar, E [Gabinete de TecnologIa Medica, Facultad de Ingenieria, Universidad Nacional de San Juan (Argentina); Patino, H D [Instituto de Automatica, Facultad de Ingenieria, Universidad Nacional de San Juan (Argentina); Valentinuzzi, M E [Instituto Superior de Investigaciones Biologicas (INSIBIO), UNT-CONICET, Tucuman (Argentina)

    2007-11-15

    Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three adaptive filters based on a least mean squares (LMS) algorithm is proposed. The first one eliminates line interference, the second adaptive filter removes the ECG artifacts and the last one cancels EOG spikes. Each stage uses a finite impulse response (FIR) filter, which adjusts its coefficients to produce an output similar to the artifacts present in the EEG. The proposed cascade adaptive filter was tested in five real EEG records acquired in polysomnographic studies. In all cases, line-frequency, ECG and EOG artifacts were attenuated. It is concluded that the proposed filter reduces the common artifacts present in EEG signals without removing significant information embedded in these records.

  5. Fast optically sectioned fluorescence HiLo endomicroscopy

    Science.gov (United States)

    Ford, Tim N.; Lim, Daryl; Mertz, Jerome

    2012-02-01

    We describe a nonscanning, fiber bundle endomicroscope that performs optically sectioned fluorescence imaging with fast frame rates and real-time processing. Our sectioning technique is based on HiLo imaging, wherein two widefield images are acquired under uniform and structured illumination and numerically processed to reject out-of-focus background. This work is an improvement upon an earlier demonstration of widefield optical sectioning through a flexible fiber bundle. The improved device features lateral and axial resolutions of 2.6 and 17 μm, respectively, a net frame rate of 9.5 Hz obtained by real-time image processing with a graphics processing unit (GPU) and significantly reduced motion artifacts obtained by the use of a double-shutter camera. We demonstrate the performance of our system with optically sectioned images and videos of a fluorescently labeled chorioallantoic membrane (CAM) in the developing G. gallus embryo. HiLo endomicroscopy is a candidate technique for low-cost, high-speed clinical optical biopsies.

  6. Data-driven motion correction in brain SPECT

    International Nuclear Information System (INIS)

    Kyme, A.Z.; Hutton, B.F.; Hatton, R.L.; Skerrett, D.W.

    2002-01-01

    Patient motion can cause image artifacts in SPECT despite restraining measures. Data-driven detection and correction of motion can be achieved by comparison of acquired data with the forward-projections. By optimising the orientation of the reconstruction, parameters can be obtained for each misaligned projection and applied to update this volume using a 3D reconstruction algorithm. Digital and physical phantom validation was performed to investigate this approach. Noisy projection data simulating at least one fully 3D patient head movement during acquisition were constructed by projecting the digital Huffman brain phantom at various orientations. Motion correction was applied to the reconstructed studies. The importance of including attenuation effects in the estimation of motion and the need for implementing an iterated correction were assessed in the process. Correction success was assessed visually for artifact reduction, and quantitatively using a mean square difference (MSD) measure. Physical Huffman phantom studies with deliberate movements introduced during the acquisition were also acquired and motion corrected. Effective artifact reduction in the simulated corrupt studies was achieved by motion correction. Typically the MSD ratio between the corrected and reference studies compared to the corrupted and reference studies was > 2. Motion correction could be achieved without inclusion of attenuation effects in the motion estimation stage, providing simpler implementation and greater efficiency. Moreover the additional improvement with multiple iterations of the approach was small. Improvement was also observed in the physical phantom data, though the technique appeared limited here by an object symmetry. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. High-fidelity artifact correction for cone-beam CT imaging of the brain

    Science.gov (United States)

    Sisniega, A.; Zbijewski, W.; Xu, J.; Dang, H.; Stayman, J. W.; Yorkston, J.; Aygun, N.; Koliatsos, V.; Siewerdsen, J. H.

    2015-02-01

    CT is the frontline imaging modality for diagnosis of acute traumatic brain injury (TBI), involving the detection of fresh blood in the brain (contrast of 30-50 HU, detail size down to 1 mm) in a non-contrast-enhanced exam. A dedicated point-of-care imaging system based on cone-beam CT (CBCT) could benefit early detection of TBI and improve direction to appropriate therapy. However, flat-panel detector (FPD) CBCT is challenged by artifacts that degrade contrast resolution and limit application in soft-tissue imaging. We present and evaluate a fairly comprehensive framework for artifact correction to enable soft-tissue brain imaging with FPD CBCT. The framework includes a fast Monte Carlo (MC)-based scatter estimation method complemented by corrections for detector lag, veiling glare, and beam hardening. The fast MC scatter estimation combines GPU acceleration, variance reduction, and simulation with a low number of photon histories and reduced number of projection angles (sparse MC) augmented by kernel de-noising to yield a runtime of ~4 min per scan. Scatter correction is combined with two-pass beam hardening correction. Detector lag correction is based on temporal deconvolution of the measured lag response function. The effects of detector veiling glare are reduced by deconvolution of the glare response function representing the long range tails of the detector point-spread function. The performance of the correction framework is quantified in experiments using a realistic head phantom on a testbench for FPD CBCT. Uncorrected reconstructions were non-diagnostic for soft-tissue imaging tasks in the brain. After processing with the artifact correction framework, image uniformity was substantially improved, and artifacts were reduced to a level that enabled visualization of ~3 mm simulated bleeds throughout the brain. Non-uniformity (cupping) was reduced by a factor of 5, and contrast of simulated bleeds was improved from ~7 to 49.7 HU, in good agreement

  8. SU-F-J-115: Target Volume and Artifact Evaluation of a New Device-Less 4D CT Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Martin, R; Pan, T [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: 4DCT is often used in radiation therapy treatment planning to define the extent of motion of the visible tumor (IGTV). Recent available software allows 4DCT images to be created without the use of an external motion surrogate. This study aims to compare this device-less algorithm to a standard device-driven technique (RPM) in regards to artifacts and the creation of treatment volumes. Methods: 34 lung cancer patients who had previously received a cine 4DCT scan on a GE scanner with an RPM determined respiratory signal were selected. Cine images were sorted into 10 phases based on both the RPM signal and the device-less algorithm. Contours were created on standard and device-less maximum intensity projection (MIP) images using a region growing algorithm and manual adjustment to remove other structures. Variations in measurements due to intra-observer differences in contouring were assessed by repeating a subset of 6 patients 2 additional times. Artifacts in each phase image were assessed using normalized cross correlation at each bed position transition. A score between +1 (artifacts “better” in all phases for device-less) and −1 (RPM similarly better) was assigned for each patient based on these results. Results: Device-less IGTV contours were 2.1 ± 1.0% smaller than standard IGTV contours (not significant, p = 0.15). The Dice similarity coefficient (DSC) was 0.950 ± 0.006 indicating good similarity between the contours. Intra-observer variation resulted in standard deviations of 1.2 percentage points in percent volume difference and 0.005 in DSC measurements. Only two patients had improved artifacts with RPM, and the average artifact score (0.40) was significantly greater than zero. Conclusion: Device-less 4DCT can be used in place of the standard method for target definition due to no observed difference between standard and device-less IGTVs. Phase image artifacts were significantly reduced with the device-less method.

  9. The use of active breathing control (ABC) to reduce margin for breathing motion

    International Nuclear Information System (INIS)

    Wong, John W.; Sharpe, Michael B.; Jaffray, David A.; Kini, Vijay R.; Robertson, John M.; Stromberg, Jannifer S.; Martinez, Alavro A.

    1999-01-01

    . The variation of the organ positions and volumes for the different scans were quantified and compared. Results: The ABC procedure was well tolerated in the 12 patients. When ABC was applied near the end of normal expiration, the minimal duration of active breath-hold was 15 s for 1 patient with lung cancer, and 20 s or more for all other patients. The duration was greater than 40 s for 2 patients with Hodgkin's disease when ABC was applied during deep inspiration. Scan artifacts associated with normal breathing motion were not observed in the ABC scans. The analysis of the small set of intrafraction scan data indicated that with ABC, the liver volumes were reproducible at about 1%, and lung volumes to within 6%. The excursions of a 'center of target' parameter for the livers were less than 1 mm at the same respiratory phase, but were larger than 4 mm at the extremes of the breathing cycle. The inter-fraction scan study indicated that daily setup variation contributed to the uncertainty in assessing the reproducibility of organ immobilization with ABC between treatment fractions. Conclusion: The results were encouraging; ABC provides a simple means to minimize breathing motion. When applied for CT scanning and treatment, the ABC procedure requires no more than standard operation of the CT scanner or the medical accelerator. The ABC scans are void of motion artifacts commonly seen on fast spiral CT scans. When acquired at different points in the breathing cycle, these ABC scans show organ motion in three-dimension (3D) that can be used to enhance treatment planning. Reproducibility of organ immobilization with ABC throughout the course of treatment must be quantified before the procedure can be applied to reduce margin for conformal treatment

  10. Historical Artifact Collection at the East Tennessee Technology Park

    International Nuclear Information System (INIS)

    Goodpasture, S.T.; Wood, S.K.

    2009-01-01

    The East Tennessee Technology Park (ETTP) was originally built during World War II as part of the Manhattan Project. Known as the K-25 Site, its primary mission was to enrich uranium for use in atomic weapons. During the Cold War, the site's mission was changed to include the enrichment of uranium for nuclear reactor fuel elements and to recycle spent fuel. In the 1980's, a reduction in the demand for nuclear fuel resulted in the shutdown of the enrichment process and production ceased. The emphasis of the mission for the ETTP was then changed to environmental management and restoration operation. Beginning in the 1990's, re-industrialization (conversion of under-utilized government facilities for use by the private sector) became a major mission at the ETTP. These activities involve cleaning and demolishing facilities. Decommission and demolition (D and D) of facilities at the ETTP or Manhattan Project K-25 Gaseous Diffusion Plant on the U.S. Department of Energy's (DOE) Oak Ridge Reservation (ORR) presented significant challenges complying with the requirements of the National Historic Preservation Act (NHPA) Memorandum of Agreement (MOA) that was negotiated with the stakeholders. Development of a process to identify, record and preserve the artifacts and the cooperation of several agencies and contractors were critical to completing the collection of the artifacts without impacting the D and D project schedule. Additional challenges included contaminated and classified artifacts, entry to facilities with hazardous conditions, schedule pressures and funding for collection and permanent storage. A process was developed to achieve compliance with the requirements of the NHPA. The NHPA requirements and implementing instruments at the ETTP as well as the process developed to preserve significant Manhattan Project era artifacts at the ETTP will be discussed. Implementation of the artifact collection process is also summarized. The challenge of complying with the

  11. Management of respiratory motion in radiation oncology

    International Nuclear Information System (INIS)

    Vedam, Subrahmanya Sastry

    2003-01-01

    images obtained during simulation by reducing the motion artifacts typically seen during CT imaging. An analysis of several patient breathing patterns with (audio instructions and visual feedback) and without training, indicated that breathing training improved the reproducibility of amplitude and/or frequency of patient breathing cycles. A phantom based study by superposition of sinusoidal motion of a 'simulated' tumor onto the initial beam aperture as formed by the multileaf collimator revealed that target dose measurements obtained with such a motion synchronized setup were equivalent to those delivered to a static target by a static beam. An attempt to acquire respiration synchronized (4D) CT images of a motion phantom and a patient also yielded a 4D CT data set with reduced motion artifacts. Respiratory gated and respiration synchronized radiotherapy are both viable approaches to account for respiratory motion during radiotherapy. While respiratory gated radiotherapy has been successfully implemented in some centers, several technical advances are required for clinical implementation of respiration synchronized radiotherapy. Future applicability of either of the above approaches as routine treatment procedures will be determined by their potential clinical gains over currently available methods

  12. Electro-optic deflectors deliver advantages over acousto-optical deflectors in a high resolution, ultra-fast force-clamp optical trap.

    Science.gov (United States)

    Woody, Michael S; Capitanio, Marco; Ostap, E Michael; Goldman, Yale E

    2018-04-30

    We characterized experimental artifacts arising from the non-linear response of acousto-optical deflectors (AODs) in an ultra-fast force-clamp optical trap and have shown that using electro-optical deflectors (EODs) instead eliminates these artifacts. We give an example of the effects of these artifacts in our ultra-fast force clamp studies of the interaction of myosin with actin filaments. The experimental setup, based on the concept of Capitanio et al. [Nat. Methods 9, 1013-1019 (2012)] utilizes a bead-actin-bead dumbbell held in two force-clamped optical traps which apply a load to the dumbbell to move it at a constant velocity. When myosin binds to actin, the filament motion stops quickly as the total force from the optical traps is transferred to the actomyosin attachment. We found that in our setup, AODs were unsuitable for beam steering due to non-linear variations in beam intensity and deflection angle as a function of driving frequency, likely caused by low-amplitude standing acoustic waves in the deflectors. These aberrations caused instability in the force feedback loops leading to artifactual jumps in the trap position. We demonstrate that beam steering with EODs improves the performance of our instrument. Combining the superior beam-steering capability of the EODs, force acquisition via back-focal-plane interferometry, and dual high-speed FPGA-based feedback loops, we apply precise and constant loads to study the dynamics of interactions between actin and myosin. The same concept applies to studies of other biomolecular interactions.

  13. List mode reconstructions for PET with motion compensation: A simulation study

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2002-01-01

    Motion artifacts can be a significant factor that limits the image quality in high-resolution PET. Surveillance systems have been developed to track the movements of the subject during a scan. Development of reconstruction algorithms that are able to compensate for the subject motion will increase the potential of PET. In this paper we present a list mode likelihood reconstruction algorithm with the ability of motion compensation. The subject motion is explicitly modeled in the likelihood function. The detections of each detector pair are modeled as a Poisson process with time-varying rate function. The proposed method has several advantages over the existing methods. It uses all detected events and does not introduce any interpolation error. Computer simulations show that the proposed method can compensate simulated subject movements and that the reconstructed images have no visible motion artifacts

  14. Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imagining slabs in free-breathing children: Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Allmendinger, Thomas [Siemens Healthcare, GmbH, Computed Tomography Division, Forchheim (Germany)

    2017-09-15

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.

  15. Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imagining slabs in free-breathing children: Initial experience

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Allmendinger, Thomas

    2017-01-01

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children

  16. Preliminary study on helical CT algorithms for patient motion estimation and compensation

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    1995-01-01

    Helical computed tomography (helical/spiral CT) has replaced conventional CT in many clinical applications. In current helical CT, a patient is assumed to be rigid and motionless during scanning and planar projection sets are produced from raw data via longitudinal interpolation. However, rigid patient motion is a problem in some cases (such as in the skull base and temporal bone imaging). Motion artifacts thus generated in reconstructed images can prevent accurate diagnosis. Modeling a uniform translational movement, the authors address how patient motion is ascertained and how it may be compensated. First, mismatch between adjacent fan-beam projections of the same orientation is determined via classical correlation, which is approximately proportional to the patient displacement projected onto an axis orthogonal to the central ray of the involved fan-beam. Then, the patient motion vector (the patient displacement per gantry rotation) is estimated from its projections using a least-square-root method. To suppress motion artifacts, adaptive interpolation algorithms are developed that synthesize full-scan and half-scan planar projection data sets, respectively. In the adaptive scheme, the interpolation is performed along inclined paths dependent upon the patient motion vector. The simulation results show that the patient motion vector can be accurately and reliably estimated using their correlation and least-square-root algorithm, patient motion artifacts can be effectively suppressed via adaptive interpolation, and adaptive half-scan interpolation is advantageous compared with its full-scale counterpart in terms of high contrast image resolution

  17. Positron emission tomography/computed tomography--imaging protocols, artifacts, and pitfalls.

    Science.gov (United States)

    Bockisch, Andreas; Beyer, Thomas; Antoch, Gerald; Freudenberg, Lutz S; Kühl, Hilmar; Debatin, Jörg F; Müller, Stefan P

    2004-01-01

    There has been a longstanding interest in fused images of anatomical information, such as that provided by computed tomography (CT) or magnetic resonance imaging (MRI) systems, with biological information obtainable by positron emission tomography (PET). The near-simultaneous data acquisition in a fixed combination of a PET and a CT scanner in a combined PET/CT imaging system minimizes spatial and temporal mismatches between the modalities by eliminating the need to move the patient in between exams. In addition, using the fast CT scan for PET attenuation correction, the duration of the examination is significantly reduced compared to standalone PET imaging with standard rod-transmission sources. The main source of artifacts arises from the use of the CT-data for scatter and attenuation correction of the PET images. Today, CT reconstruction algorithms cannot account for the presence of metal implants, such as dental fillings or prostheses, properly, thus resulting in streak artifacts, which are propagated into the PET image by the attenuation correction. The transformation of attenuation coefficients at X-ray energies to those at 511 keV works well for soft tissues, bone, and air, but again is insufficient for dense CT contrast agents, such as iodine or barium. Finally, mismatches, for example, due to uncoordinated respiration result in incorrect attenuation-corrected PET images. These artifacts, however, can be minimized or avoided prospectively by careful acquisition protocol considerations. In doubt, the uncorrected images almost always allow discrimination between true and artificial finding. PET/CT has to be integrated into the diagnostic workflow for harvesting the full potential of the new modality. In particular, the diagnostic power of both, the CT and the PET within the combination must not be underestimated. By combining multiple diagnostic studies within a single examination, significant logistic advantages can be expected if the combined PET

  18. Artifacts by dental materials on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Choi, Deuk Lin; Kim, Ki Jung; Suh, Won Hyuck

    1992-01-01

    Magnetic resonance imaging (MRI) has proved to be a valuable method for evaluation of the head and neck. Unfortunately, metallic devices associated with certain dental fillings and appliances often cause variable artifacts that can obscure normal or pathologic conditions on MR and computed tomography. In this work, we assessed the MR appearance of dental prosthetic materials in vitro and in vivo including precious alloys, nonprecions alloys, resin, amalgam and titanium alloy. For in vivo studies, these materials were placed in healthy volunteer's mouths and then images were assessed. Analysis of the appearance of shape and extent of artifact, and observed influence of these artifacts on the image interpretation at 0.2 Tesla permanent type MR scanner were valuated. Material used as temporary or permanent filling of crowns such as amalgam, precious alloy and, microfilled resin did not cause artifact on the image. The size of the artifact produced by the nonprecious alloys was influenced by the ferromagnetism of the object and the volume prosthesis, and was related to the scanning sequence. Nonprecious alloys produced minimal local signal distortion, where precious alloys, and dental resin had no effect on the MR images in vivo. These results were mainly from a low field strength MR scanner used in this study

  19. Ensemble Artifact Design For Context Sensitive Decision Support

    Directory of Open Access Journals (Sweden)

    Shah J Miah

    2014-06-01

    Full Text Available Although an improvement of design knowledge is an essential goal of design research, current design research predominantly focuses on knowledge concerning the IT artifact (tool design process, rather than a more holistic understanding encompassing the dynamic usage contexts of a technological artifact. Conceptualising a design in context as an “ensemble artifact” (Sein et al., 2011 provides the basis for a more rigorous treatment. This paper describes an IS artifact design framework that has been generated from the development of several practitioner-oriented decision support systems (DSS in which contextual aspects relevant to practitioners’ decision making are considered as integral design themes. We describe five key dimensions of an ensemble artifact design and show their value in designing practitioner-oriented DSS. The features are user centredness, knowledge sharing, situation-specific customisation, reduced model orientation, and practice based secondary design abilities. It is argued that this understanding can contribute to design research knowledge more effectively both to develop dynamic DSS, and by its extensibility to other artifact designs.

  20. Metal artifact reduction method using metal streaks image subtraction

    International Nuclear Information System (INIS)

    Pua, Rizza D.; Cho, Seung Ryong

    2014-01-01

    Many studies have been dedicated for metal artifact reduction (MAR); however, the methods are successful to varying degrees depending on situations. Sinogram in-painting, filtering, iterative method are some of the major categories of MAR. Each has its own merits and weaknesses. A combination of these methods or hybrid methods have also been developed to make use of the different benefits of two techniques and minimize the unfavorable results. Our method focuses on the in-paitning approach and a hybrid MAR described by Xia et al. Although in-painting scheme is an effective technique in reducing the primary metal artifacts, a major drawback is the reintroduction of new artifacts that can be caused by an inaccurate interpolation process. Furthermore, combining the segmented metal image to the corrected nonmetal image in the final step of a conventional inpainting approach causes an issue of incorrect metal pixel values. Our proposed method begins with a sinogram in-painting approach and ends with an image-based metal artifact reduction scheme. This work provides a simple, yet effective solution for reducing metal artifacts and acquiring the original metal pixel information. The proposed method demonstrated its effectiveness in a simulation setting. The proposed method showed image quality that is comparable to the standard MAR; however, quantitatively more accurate than the standard MAR

  1. Preliminary experimental insights into differential heat impact among lithic artifacts

    Directory of Open Access Journals (Sweden)

    Guillermo Bustos-Pérez

    2016-09-01

    Full Text Available The presence of thermally altered and broken flint artifacts is common at archaeological sites. Most studies focus their attention on the effects of heat treatment on flint to improve knapping qualities, disregarding the effects of fire over flint under uncontrolled conditions. This paper aims to show how under uncontrolled heating processes flint artifacts develop different heat alterations (such as levels of breakage, presence of scales, etc. as a result of vertical distribution, volume or raw material and to establish a gradient of rock changes and behavior. Artifacts where macroscopically analyzed and a series of uncontrolled heating experiments through the distribution of flint blanks under two hearths were carried out, allowing a comparison of the before and after of the blanks. Preliminary results show how levels of breakage, surface alteration or development of heat alteration features can be differentiated according to artifact volume, vertical distribution and level of surface alteration. Results also show how two different raw materials react differently to similar thermal impact, and how surface alteration reacts at different rhythm in the case of recycled artifacts. We conclude that levels of thermal alteration can be differentiated through macroscopic analysis of flint surface.

  2. Structuring Design and Evaluation of an Interactive Installation Through Swarms of Light Rays with Human-Artifact Model

    DEFF Research Database (Denmark)

    Erkut, Cumhur; Fehr, Jonas

    2016-01-01

    We present the design and evaluation of an interactive installation to be explored by movement and sound under Human-Activity Model. In the installation, movement qualities that are extracted from the motion tracking data excite a dynamical system (a synthetic flock of agents), which responds...... out a questionnaire afterwards. In this paper, we report our preliminary work on the analysis of the tensions of interaction with the installation under the Human-Artifact Model. Our results indicate exploration and discovery as the main motives of the interaction. This is different than utilitarian...

  3. Metal artifact removal (MAR) analysis for the security inspections using the X-ray computed tomography

    International Nuclear Information System (INIS)

    Cho, Hyo Sung; Woo, Tae Ho; Park, Chul Kyu

    2016-01-01

    Using the metal artifact property, it is analyzed for the X-ray computed tomography (CT) in the aspect of the security on the examined places like airport and surveillance areas. Since the importance of terror prevention strategy has been increased, the security application of X-ray CT has the significant remark. One shot X-ray image has the limitation to find out the exact shape to property in the closed box, which could be solved by the CT scanning without the tearing off the box in this work. Cleaner images can be obtained by the advanced technology if the CT scanning is utilized in the security purposes on the secured areas. A metal sample is treated by the metal artifact removal (MAR) method for the enhanced image. The mimicked explosive is experimented for the imaging processing application where the cleaner one is obtained. The procedure is explained and the further study is discussed. - Highlights: • The X-ray image is used for the nuclear inspections which are made by the image processing. • Nuclear security has been performed for counterterrorism. • Easy and fast inspections are needed. • Metal shows the characteristics of the noises.

  4. Distinction of Fly Artifacts from Human Blood using Immunodetection.

    Science.gov (United States)

    Rivers, David B; Acca, Gillian; Fink, Marc; Brogan, Rebecca; Chen, Dorothy; Schoeffield, Andrew

    2018-02-21

    Insect stains produced by necrophagous flies are indistinguishable morphologically from human bloodstains. At present, no diagnostic tests exist to overcome this deficiency. As the first step toward developing a chemical test to recognize fly artifacts, polyclonal antisera were generated in rats against three distinct antigenic sequences of fly cathepsin D-like proteinase, an enzyme that is structurally distinct in cyclorrhaphous Diptera from other animals. The resulting rat antisera bound to artifacts produced by Protophormia terraenovae and synthetic peptides used to generate the polyclonal antisera, but not with any type of mammalian blood tested in immunoassays. Among the three antisera, anti-md3 serum displayed the highest reactivity for fly stains, demonstrated cross-reactivity for all synthetic peptides representing antigenic sequences of the mature fly enzyme, and bound artifacts originating from the fly digestive tract. Further work is needed to determine whether the antisera are suitable for non-laboratory conditions. © 2018 American Academy of Forensic Sciences.

  5. Streak artifacts on Kidney CT: Ionic vs nonionic contrast media

    International Nuclear Information System (INIS)

    Cho, Eun Ok; Kim, Won Hong; Jung, Myung Suk; Kim, Yong Hoon; Hur, Gham

    1993-01-01

    The authors reviewed findings of enhanced abdominal computed tomography (CT) scans to know the difference between a higher dose of conventional ionic contrast media(iothalamate meglumine) and a lower dose of a new, nonionic contrast material(ioversol). One hundred adult patients were divided into two groups. Each group consisted of 50 patients. Iothalamate meglumine and ioversol were intravenously administered in each group. The radio of the male to female in the former was 28:22, and the latter 29:21. We examine the degree of renal streak artifact and measure the Hounsfield number of urine in renal collecting system. There were significant differences of the degree of the streak artifact depending upon the osmolality of contrast media used and that was related with urine CT number(P value<0.005). We authors conclude that nonionic low osmolar contrast media is prone to cause streak artifacts and distortions of renal image than conventional ionic high osmolar contrast media

  6. Correction of ring artifacts in X-ray tomographic images

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Johnson, G.; Tafforeau, P.

    2011-01-01

    Ring artifacts are systematic intensity distortions located on concentric circles in reconstructed tomographic X-ray images. When using X-ray tomography to study for instance low-contrast grain boundaries in metals it is crucial to correct for the ring artifacts in the images as they may have...... the same intensity level as the grain boundaries and thus make it impossible to perform grain segmentation. This paper describes an implementation of a method for correcting the ring artifacts in tomographic X-ray images of simple objects such as metal samples where the object and the background...... are separable. The method is implemented in Matlab, it works with very little user interaction and may run in parallel on a cluster if applied to a whole stack of images. The strength and robustness of the method implemented will be demonstrated on three tomographic X-ray data sets: a mono-phase β...

  7. Medical image of the week: DBS polysomnogram artifact

    Directory of Open Access Journals (Sweden)

    Shetty S,

    2015-10-01

    Full Text Available A 79-year-old man with known Parkinson’s disease and status post deep brain stimulator (DBS implantation underwent an overnight polysomnogram for clinical suspicion of obstructive sleep apnea. Artifact was seen on the polysomnogram recording (Figures 1 & 2. Patient-related electrical artifacts may be seen from devices such as pacemakers, deep brain stimulators and vagal nerve simulators. Abrupt discontinuation of DBS is associated with a high likelihood of worsening of symptoms in patients with Parkinson’s disease (1. Patients with DBS are most commonly programmed in monopolar mode. Bipolar configuration, forms a short electrical dipole that affects a relatively smaller volume of tissue and generates far less artifact, suggesting that this may be an effective option in a Parkinsonian patient with indications for polysomnography (2.

  8. Motion Detection in Ultrasound Image-Sequences Using Tensor Voting

    Science.gov (United States)

    Inba, Masafumi; Yanagida, Hirotaka; Tamura, Yasutaka

    2008-05-01

    Motion detection in ultrasound image sequences using tensor voting is described. We have been developing an ultrasound imaging system adopting a combination of coded excitation and synthetic aperture focusing techniques. In our method, frame rate of the system at distance of 150 mm reaches 5000 frame/s. Sparse array and short duration coded ultrasound signals are used for high-speed data acquisition. However, many artifacts appear in the reconstructed image sequences because of the incompleteness of the transmitted code. To reduce the artifacts, we have examined the application of tensor voting to the imaging method which adopts both coded excitation and synthetic aperture techniques. In this study, the basis of applying tensor voting and the motion detection method to ultrasound images is derived. It was confirmed that velocity detection and feature enhancement are possible using tensor voting in the time and space of simulated ultrasound three-dimensional image sequences.

  9. Ring artifacts removal from synchrotron CT image slices

    International Nuclear Information System (INIS)

    Wei Zhouping; Chapman, Dean; Wiebe, Sheldon

    2013-01-01

    Ring artifacts can occur in reconstructed images from x-ray Computerized Tomography (CT) as full or partial concentric rings superimposed on the scanned structures. Due to the data corruption by those ring artifacts in CT images, qualitative and quantitative analysis of these images are compromised. In this paper, we propose to correct the ring artifacts on the reconstructed synchrotron radiation (SR) CT image slices. The proposed correction procedure includes the following steps: (1). transform the reconstructed CT images into polar coordinates; (2) apply discrete two-dimensional (2D) wavelet transform to the polar image to decompose it into four image components: low pass band image component, as well as the components from horizontal, vertical and diagonal details bands; (3). apply 2D Fourier transform to the vertical details band image component only, since the ring artifacts become vertical lines in the polar coordinates; (4). apply Gaussian filtering in Fourier domain along the abscissa direction to suppress the vertical lines, since the information of the vertical lines in Fourier domain is completely condensed to that direction; (5). perform inverse Fourier transform to get the corrected vertical details band image component; (6). perform inverse wavelet transform to get the corrected polar image; (7). transform the corrected polar image back to Cartesian coordinates to get the CT image slice with reduced ring artifacts. This approach has been successfully used on CT data acquired from the Biomedical Imaging and Therapy (BMIT) beamline in Canadian Light Source (CLS), and the results show that the ring artifacts in original SR CT images have been effectively suppressed with all the structure information in the image preserved.

  10. Simulation-based artifact correction (SBAC) for metrological computed tomography

    Science.gov (United States)

    Maier, Joscha; Leinweber, Carsten; Sawall, Stefan; Stoschus, Henning; Ballach, Frederic; Müller, Tobias; Hammer, Michael; Christoph, Ralf; Kachelrieß, Marc

    2017-06-01

    Computed tomography (CT) is a valuable tool for the metrolocical assessment of industrial components. However, the application of CT to the investigation of highly attenuating objects or multi-material components is often restricted by the presence of CT artifacts caused by beam hardening, x-ray scatter, off-focal radiation, partial volume effects or the cone-beam reconstruction itself. In order to overcome this limitation, this paper proposes an approach to calculate a correction term that compensates for the contribution of artifacts and thus enables an appropriate assessment of these components using CT. Therefore, we make use of computer simulations of the CT measurement process. Based on an appropriate model of the object, e.g. an initial reconstruction or a CAD model, two simulations are carried out. One simulation considers all physical effects that cause artifacts using dedicated analytic methods as well as Monte Carlo-based models. The other one represents an ideal CT measurement i.e. a measurement in parallel beam geometry with a monochromatic, point-like x-ray source and no x-ray scattering. Thus, the difference between these simulations is an estimate for the present artifacts and can be used to correct the acquired projection data or the corresponding CT reconstruction, respectively. The performance of the proposed approach is evaluated using simulated as well as measured data of single and multi-material components. Our approach yields CT reconstructions that are nearly free of artifacts and thereby clearly outperforms commonly used artifact reduction algorithms in terms of image quality. A comparison against tactile reference measurements demonstrates the ability of the proposed approach to increase the accuracy of the metrological assessment significantly.

  11. Auditory Motion Elicits a Visual Motion Aftereffect

    Directory of Open Access Journals (Sweden)

    Christopher C. Berger

    2016-12-01

    Full Text Available The visual motion aftereffect is a visual illusion in which exposure to continuous motion in one direction leads to a subsequent illusion of visual motion in the opposite direction. Previous findings have been mixed with regard to whether this visual illusion can be induced cross-modally by auditory stimuli. Based on research on multisensory perception demonstrating the profound influence auditory perception can have on the interpretation and perceived motion of visual stimuli, we hypothesized that exposure to auditory stimuli with strong directional motion cues should induce a visual motion aftereffect. Here, we demonstrate that horizontally moving auditory stimuli induced a significant visual motion aftereffect—an effect that was driven primarily by a change in visual motion perception following exposure to leftward moving auditory stimuli. This finding is consistent with the notion that visual and auditory motion perception rely on at least partially overlapping neural substrates.

  12. Auditory Motion Elicits a Visual Motion Aftereffect.

    Science.gov (United States)

    Berger, Christopher C; Ehrsson, H Henrik

    2016-01-01

    The visual motion aftereffect is a visual illusion in which exposure to continuous motion in one direction leads to a subsequent illusion of visual motion in the opposite direction. Previous findings have been mixed with regard to whether this visual illusion can be induced cross-modally by auditory stimuli. Based on research on multisensory perception demonstrating the profound influence auditory perception can have on the interpretation and perceived motion of visual stimuli, we hypothesized that exposure to auditory stimuli with strong directional motion cues should induce a visual motion aftereffect. Here, we demonstrate that horizontally moving auditory stimuli induced a significant visual motion aftereffect-an effect that was driven primarily by a change in visual motion perception following exposure to leftward moving auditory stimuli. This finding is consistent with the notion that visual and auditory motion perception rely on at least partially overlapping neural substrates.

  13. Auditory motion capturing ambiguous visual motion

    Directory of Open Access Journals (Sweden)

    Arjen eAlink

    2012-01-01

    Full Text Available In this study, it is demonstrated that moving sounds have an effect on the direction in which one sees visual stimuli move. During the main experiment sounds were presented consecutively at four speaker locations inducing left- or rightwards auditory apparent motion. On the path of auditory apparent motion, visual apparent motion stimuli were presented with a high degree of directional ambiguity. The main outcome of this experiment is that our participants perceived visual apparent motion stimuli that were ambiguous (equally likely to be perceived as moving left- or rightwards more often as moving in the same direction than in the opposite direction of auditory apparent motion. During the control experiment we replicated this finding and found no effect of sound motion direction on eye movements. This indicates that auditory motion can capture our visual motion percept when visual motion direction is insufficiently determinate without affecting eye movements.

  14. Inter-deriving Semantic Artifacts for Object-Oriented Programming

    DEFF Research Database (Denmark)

    Danvy, Olivier; Johannsen, Jacob

    2008-01-01

    We present a new abstract machine for Abadi and Cardelli's untyped calculus of objects. What is special about this semantic artifact (i.e., man-made construct) is that is mechanically corresponds to both the reduction semantics (i.e., small-step operational semantics) and the natural semantics (i...... actual substitutions, we then represent object methods as closures and in the same inter-derivational spirit, we present three new semantic artifacts: a reduction semantics for a version of Abadi and Cardelli's untyped calculus of objects with explicit substitutions, an environment-based abstract machine...

  15. EEG Artifact Removal Using a Wavelet Neural Network

    Science.gov (United States)

    Nguyen, Hoang-Anh T.; Musson, John; Li, Jiang; McKenzie, Frederick; Zhang, Guangfan; Xu, Roger; Richey, Carl; Schnell, Tom

    2011-01-01

    !n this paper we developed a wavelet neural network. (WNN) algorithm for Electroencephalogram (EEG) artifact removal without electrooculographic (EOG) recordings. The algorithm combines the universal approximation characteristics of neural network and the time/frequency property of wavelet. We. compared the WNN algorithm with .the ICA technique ,and a wavelet thresholding method, which was realized by using the Stein's unbiased risk estimate (SURE) with an adaptive gradient-based optimal threshold. Experimental results on a driving test data set show that WNN can remove EEG artifacts effectively without diminishing useful EEG information even for very noisy data.

  16. ["Long-branch Attraction" artifact in phylogenetic reconstruction].

    Science.gov (United States)

    Li, Yi-Wei; Yu, Li; Zhang, Ya-Ping

    2007-06-01

    Phylogenetic reconstruction among various organisms not only helps understand their evolutionary history but also reveal several fundamental evolutionary questions. Understanding of the evolutionary relationships among organisms establishes the foundation for the investigations of other biological disciplines. However, almost all the widely used phylogenetic methods have limitations which fail to eliminate systematic errors effectively, preventing the reconstruction of true organismal relationships. "Long-branch Attraction" (LBA) artifact is one of the most disturbing factors in phylogenetic reconstruction. In this review, the conception and analytic method as well as the avoidance strategy of LBA were summarized. In addition, several typical examples were provided. The approach to avoid and resolve LBA artifact has been discussed.

  17. Analysis of main artifacts in scanning probe microscopy (1)

    International Nuclear Information System (INIS)

    Alekperov, S.D.; Alekperov, S.D.

    2012-01-01

    The analysis of experiment carrying methodology in the scanning probe microscopy (SPM) region is carried out, the main parameters influencing on image quality are revealed. In order to reveal the artifact reason the main components of SPM signal which are divided on 5 groups : the useful signal; noises connected with external influences and temperature drift; distortions connected with piezoceramics and piezo-scanner non-ideality; probe geometry influence; apparatus noises are considered. The main methods of removal and minimization of the given artifacts are considered. The second and third groups of main components of SPM signal are considered in the articles first part

  18. "Diabetes and literacy: negotiating control through artifacts of medicalization".

    Science.gov (United States)

    Martins, David S

    2009-06-01

    My experience with the California Department of Motor Vehicles offers a case to explore how bureaucratic institutions monitor, classify, and control individuals. By examining artifacts created for and used by the DMV through the lens of literacy studies, I discuss the variety of rhetorical strategies used in each document and the effects and implications of those strategies, for example on subjectivity or identity, and move beyond the language of the artifacts themselves to attend to how they are invested with power in the management and control of populations.

  19. Depolarization artifacts in dual rotating-compensator Mueller matrix ellipsometry

    International Nuclear Information System (INIS)

    Li, Weiqi; Zhang, Chuanwei; Jiang, Hao; Chen, Xiuguo; Liu, Shiyuan

    2016-01-01

    Noticeable depolarization effects are observed in the measurement of the air using an in-house developed dual rotating-compensator Mueller matrix ellipsometer. We demonstrate that these depolarization effects are essentially artifacts and mainly induced when the compensator with wavelength-dependent optical properties is integrated with the finite bandwidth detector. We define a general formula to represent the actual Mueller matrix of the compensator by taking into account the depolarization artifacts. After incorporating this formula into the system model, a correction method is further proposed, and consequently, improved accuracy can be achieved in the Mueller matrix measurement. (paper)

  20. Motion correction in neurological fan beam SPECT using motion tracking and fully 3D reconstruction

    International Nuclear Information System (INIS)

    Fulton, R.R.; Hutton, B.; Eberl, S.; Meikle, S.; Braun, M.; Westmead Hospital, Westmead, NSW; University of Technology, Sydney, NSW

    1998-01-01

    Full text: We have previously proposed the use of fully three-dimensional (3D) reconstruction and continuous monitoring of head position to correct for motion artifacts in neurological SPECT and PET. Knowledge of the motion during acquisition provided by a head tracking system can be used to reposition the projection data in space in such a way as to negate motion effects during reconstruction. The reconstruction algorithm must deal with variations in the projection geometry resulting from differences in the timing and nature of motion between patients. Rotational movements about any axis other than the camera's axis of rotation give rise to projection geometries which necessitate the use of a fully 3D reconstruction algorithm. Our previous work with computer simulations assuming parallel hole collimation demonstrated the feasibility of correcting for motion. We have now refined our iterative 3D reconstruction algorithm to support fan beam data and attenuation correction, and developed a practical head tracking system for use on a Trionix Triad SPECT system. The correction technique has been tested in fan beam SPECT studies of the 3D Hoffman brain phantom. Arbitrary movements were applied to the phantom during acquisition and recorded by the head tracker which monitored the position and orientation of the phantom throughout the study. 3D reconstruction was then performed using the motion data provided by the tracker. The accuracy of correction was assessed by comparing the corrected images with a motion free study acquired immediately beforehand, visually and by calculating mean squared error (MSE). Motion correction reduced distortion perceptibly and, depending on the motions applied, improved MSE by up to an order of magnitude. 3D reconstruction of the 128x128x128 data set took 20 minutes on a SUN Ultra 1 workstation. The results of these phantom experiments suggest that the technique can effectively compensate for head motion under clinical SPECT imaging

  1. Robust motion correction and outlier rejection of in vivo functional MR images of the fetal brain and placenta during maternal hyperoxia

    OpenAIRE

    You, Wonsang; Serag, Ahmed; Evangelou, Iordanis E.; Andescavage, Nickie; Limperopoulos, Catherine

    2017-01-01

    Subject motion is a major challenge in functional magnetic resonance imaging studies (fMRI) of the fetal brain and placenta during maternal hyperoxia. We propose a motion correction and volume outlier rejection method for the correction of severe motion artifacts in both fetal brain and placenta. The method is optimized to the experimental design by processing different phases of acquisition separately. It also automatically excludes high-motion volumes and all the missing data are regressed ...

  2. Robust motion correction and outlier rejection of in vivo functional MR images of the fetal brain and placenta during maternal hyperoxia

    OpenAIRE

    You, Wonsang; Serag, Ahmed; Evangelou, Iordanis E.; Andescavage, Nickie; Limperopoulos, Catherine

    2015-01-01

    Subject motion is a major challenge in functional magnetic resonance imaging studies (fMRI) of the fetal brain and placenta during maternal hyperoxia. We propose a motion correction and volume outlier rejection method for the correction of severe motion artifacts in both fetal brain and placenta. The method is optimized to the experimental design by processing different phases of acquisition separately. It also automatically excludes high-motion volumes and all the missing data are regressed ...

  3. Motion control report

    CERN Document Server

    2013-01-01

    Please note this is a short discount publication. In today's manufacturing environment, Motion Control plays a major role in virtually every project.The Motion Control Report provides a comprehensive overview of the technology of Motion Control:* Design Considerations* Technologies* Methods to Control Motion* Examples of Motion Control in Systems* A Detailed Vendors List

  4. Real-Time Motion Capture Toolbox (RTMocap): an open-source code for recording 3-D motion kinematics to study action-effect anticipations during motor and social interactions.

    Science.gov (United States)

    Lewkowicz, Daniel; Delevoye-Turrell, Yvonne

    2016-03-01

    We present here a toolbox for the real-time motion capture of biological movements that runs in the cross-platform MATLAB environment (The MathWorks, Inc., Natick, MA). It provides instantaneous processing of the 3-D movement coordinates of up to 20 markers at a single instant. Available functions include (1) the setting of reference positions, areas, and trajectories of interest; (2) recording of the 3-D coordinates for each marker over the trial duration; and (3) the detection of events to use as triggers for external reinforcers (e.g., lights, sounds, or odors). Through fast online communication between the hardware controller and RTMocap, automatic trial selection is possible by means of either a preset or an adaptive criterion. Rapid preprocessing of signals is also provided, which includes artifact rejection, filtering, spline interpolation, and averaging. A key example is detailed, and three typical variations are developed (1) to provide a clear understanding of the importance of real-time control for 3-D motion in cognitive sciences and (2) to present users with simple lines of code that can be used as starting points for customizing experiments using the simple MATLAB syntax. RTMocap is freely available (http://sites.google.com/site/RTMocap/) under the GNU public license for noncommercial use and open-source development, together with sample data and extensive documentation.

  5. Motion-compensating gradients in the study of multiple sclerosis

    International Nuclear Information System (INIS)

    Runge, V.M.; Wood, M.L.; Kaufman, D.L.

    1987-01-01

    A low bandwidth motion compensating technique (no. 1) was compared with a conventional spin-echo technique (no. 2) in 20 patients with multiple sclerosis using a 1.0-T MR imaging system. In technique 1, refocusing gradients were employed to compensate for motion of constant velocity along the frequency-encoding direction. The sampling time was also increased to provide a greater S/N. Use of technique 1 was resulted in detection of 42% +- 23% more lesions (n = 8). The contrast-to-noise ratio for gray versus white matter improved by 87% +- 54% and that for lesion versus white matter by 66% +- 22%. The S/N for white matter improved by 56% +- 25%. An increase in chemical shift artifact was noted but not felt to be detrimental to lesion visualization. In the majority of cases, normal brain stem structures were more distinctly visualized. In two cases, pontine lesions were more clearly demarcated due to reduced pulsation artifacts. The combined use of refocusing gradients and low bandwidth techniques provides reduction of motion artifacts (from CSF and vessel pulsation) and improved S/N, leading to improved lesion detection

  6. The influence of respiratory motion on CT image volume definition

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez-Romero, Ruth, E-mail: rrromero@salud.madrid.org; Castro-Tejero, Pablo, E-mail: pablo.castro@salud.madrid.org [Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Puerta de Hierro Majadahonda, 28222 Madrid (Spain)

    2014-04-15

    Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath

  7. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  8. Soft tissue artifact in canine kinematic gait analysis

    NARCIS (Netherlands)

    Schwencke, M.; Smolders, L.A.; Bergknut, N.; Gustas, P.; Meij, B.P.; Hazewinkel, H.A.W.

    2012-01-01

    Vet Surg. 2012 Oct;41(7):829-37. doi: 10.1111/j.1532-950X.2012.01021.x. Soft tissue artifact in canine kinematic gait analysis. Schwencke M, Smolders LA, Bergknut N, Gustås P, Meij BP, Hazewinkel HA. Source Department of Clinical Sciences of Companion Animals,, Faculty of Veterinary Medicine,

  9. Interacting with piles of artifacts on digital tables

    NARCIS (Netherlands)

    Aliakseyeu, D.; Lucero Vera, A.A.; Subramanian, S.

    2007-01-01

    Designers and architects regularly use piles to organise visual artifacts. Recent efforts have now made it possible for users to create piles in digital systems as well. However, there is still little understanding of how users shouldinteract with digital piles. In this paper we investigate this

  10. Interacting with piles of artifacts on digital tables

    NARCIS (Netherlands)

    Aliakseyeu, D.; Subramanian, S.; Lucero Vera, A.A.; Gutwin, C.

    2006-01-01

    Designers and architects regularly use piles to organize visual artifacts. Recent efforts have now made it possible for users to create piles in digital systems as well. However, there is still little understanding of how users should interact with digital piles. In this paper we investigate this

  11. Image correction for computed tomography to remove crosstalk artifacts

    International Nuclear Information System (INIS)

    King, K.F.

    1990-01-01

    A correction method and apparatus for Computed Tomography (CT) which removes ring and streak artifacts from images by correcting for data contamination by crosstalk errors comprises subtracting from the output S o of a detector, a crosstalk factor derived from outputs of adjacent detectors. The crosstalk factors are obtained by scanning an off-centre phantom. (author)

  12. Edge artifact correction for industrial computed tomography images

    International Nuclear Information System (INIS)

    Cai Yufang; Li Dan; Wang Jue

    2013-01-01

    To eliminate the edge artifacts of industrial CT images, and improve the identification ability of the image and the precision of the dimension measurement, a coefficient adjusting method for reducing crosstalk noise is proposed. It is concluded from theoretical analysis that crosstalk generated from adjacent detectors by Compton scattering is the major reason for the edge artifacts. According to the mathematic model of the detector crosstalk, we design a special detector system configuration and stair-step phantom for estimating the quantity of crosstalk noise. The relationship between crosstalk ratio and intensity of the incident X-ray is acquired by regressing experimental data with least square method. The experimental result shows that the first-order crosstalk ratio between detectors is about 9.0%, and the second-order crosstalk ratio is about 1.2%. Thus the first-order crosstalk is the main factor causing edge artifacts. The proposed method can reduce the edge artifacts significantly, and meanwhile maintain the detail and edge of CT images. (authors)

  13. Automatic correction of dental artifacts in PET/MRI

    DEFF Research Database (Denmark)

    Ladefoged, Claes N.; Andersen, Flemming L.; Keller, Sune

    2015-01-01

    A challenge when using current magnetic resonance (MR)-based attenuation correction in positron emission tomography/MR imaging (PET/MRI) is that the MRIs can have a signal void around the dental fillings that is segmented as artificial air-regions in the attenuation map. For artifacts connected...

  14. Controlling simulations of human-artifact interaction with scenario bundles

    NARCIS (Netherlands)

    Van der Vegte, W.F.; Rusák, Z.

    2008-01-01

    We introduce a methodology for modeling and simulating fully virtual human-artifact systems, aiming to resolve two issues in virtual prototyping: (i) integration of distinct modeling and simulation approaches, and (ii) extending the deployability of simulations towards conceptual design. We are

  15. Artifacts as Stories: Understanding Families, Digital Literacies, and Storied Lives

    Science.gov (United States)

    Lewis Ellison, Tisha

    2016-01-01

    This column focuses on the interactions during family and group conversation circles that not only helped participants talk about personal, emotional, and social issues in their digital stories but also helped them make sense of artifacts and the meanings that stories carry in shared spaces and practices. This work adds to the bourgeoning…

  16. Coevolution of variability models and related software artifacts

    DEFF Research Database (Denmark)

    Passos, Leonardo; Teixeira, Leopoldo; Dinztner, Nicolas

    2015-01-01

    models coevolve with other artifact types, we study a large and complex real-world variant-rich software system: the Linux kernel. Specifically, we extract variability-coevolution patterns capturing changes in the variability model of the Linux kernel with subsequent changes in Makefiles and C source...

  17. 77 FR 40914 - Arts and Artifacts Indemnity Panel Advisory Committee

    Science.gov (United States)

    2012-07-11

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts and Artifacts Indemnity Panel Advisory Committee AGENCY: Federal Council on the Arts and the Humanities, National Endowment for the Humanities, National Foundation on the Arts and the Humanities. ACTION: Notice of meeting. SUMMARY: Pursuant to section...

  18. 77 FR 64146 - Arts and Artifacts Indemnity Panel Advisory Committee

    Science.gov (United States)

    2012-10-18

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts and Artifacts Indemnity Panel Advisory Committee AGENCY: Federal Council on the Arts and the Humanities, National Endowment for the Humanities... U.S.C. App.), notice is hereby given that the Federal Council on the Arts and the Humanities will...

  19. 78 FR 4878 - Arts and Artifacts Indemnity Panel Advisory Committee

    Science.gov (United States)

    2013-01-23

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts and Artifacts Indemnity Panel Advisory Committee AGENCY: Federal Council on the Arts and the Humanities; National Endowment for the Humanities... U.S.C. App.), notice is hereby given that the Federal Council on the Arts and the Humanities will...

  20. Artifact suppression and analysis of brain activities with electroencephalography signals.

    Science.gov (United States)

    Rashed-Al-Mahfuz, Md; Islam, Md Rabiul; Hirose, Keikichi; Molla, Md Khademul Islam

    2013-06-05

    Brain-computer interface is a communication system that connects the brain with computer (or other devices) but is not dependent on the normal output of the brain (i.e., peripheral nerve and muscle). Electro-oculogram is a dominant artifact which has a significant negative influence on further analysis of real electroencephalography data. This paper presented a data adaptive technique for artifact suppression and brain wave extraction from electroencephalography signals to detect regional brain activities. Empirical mode decomposition based adaptive thresholding approach was employed here to suppress the electro-oculogram artifact. Fractional Gaussian noise was used to determine the threshold level derived from the analysis data without any training. The purified electroencephalography signal was composed of the brain waves also called rhythmic components which represent the brain activities. The rhythmic components were extracted from each electroencephalography channel using adaptive wiener filter with the original scale. The regional brain activities were mapped on the basis of the spatial distribution of rhythmic components, and the results showed that different regions of the brain are activated in response to different stimuli. This research analyzed the activities of a single rhythmic component, alpha with respect to different motor imaginations. The experimental results showed that the proposed method is very efficient in artifact suppression and identifying individual motor imagery based on the activities of alpha component.

  1. From Artifacts to Archives: Digging into a Community's Past.

    Science.gov (United States)

    Morgan, Judy

    1991-01-01

    Presents a two-month historical research project for use in a sixth grade social studies class. Includes student use of artifacts, photographs, news clippings, maps, and oral histories obtained by interviews. Suggests that children compile a chronological history of their community to analyze, organize, and record what they have learned. (DK)

  2. Physics in the fast lane: rotors, fast ions and mobile fermions

    International Nuclear Information System (INIS)

    Price, D.L.; Saboungi, M.-L.

    1996-09-01

    Dynamic disorder in the high-temperature solid phases of the Zintl compounds CsPb and NaSn is characterized by. fast orientational motions of the polyanions and coupled motions of the cations Melting is characterized by slow translational motions of the centers of mass of the polyanions. The dynamic behavior of the ions is associated with dramatic increases in electrical conductivity characteristic of the behavior expected of a mixed conductor

  3. List mode reconstruction for PET with motion compensation: A simulation study

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2002-01-01

    Motion artifacts can be a significant factor that limits the image quality in high-resolution PET. Surveillance systems have been developed to track the movements of the subject during a scan. Development of reconstruction algorithms that are able to compensate for the subject motion will increase the potential of PET. In this paper we present a list mode likelihood reconstruction algorithm with the ability of motion compensation. The subject moti is explicitly modeled in the likelihood function. The detections of each detector pair are modeled as a Poisson process with time vary ingrate function. The proposed method has several advantages over the existing methods. It uses all detected events and does not introduce any interpolation error. Computer simulations show that the proposed method can compensate simulated subject movements and that the reconstructed images have no visible motion artifacts

  4. Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    Science.gov (United States)

    Antony, Bhavna; Abràmoff, Michael D.; Tang, Li; Ramdas, Wishal D.; Vingerling, Johannes R.; Jansonius, Nomdo M.; Lee, Kyungmoo; Kwon, Young H.; Sonka, Milan; Garvin, Mona K.

    2011-01-01

    The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate and correct the distinct axial artifacts in SD-OCT images. The method was quantitatively validated using nine pairs of OCT scans obtained with orthogonal fast-scanning axes, where a segmented surface was compared after both datasets had been corrected. The mean unsigned difference computed between the locations of this artifact-corrected surface after the single-spline and dual-spline correction was 23.36 ± 4.04 μm and 5.94 ± 1.09 μm, respectively, and showed a significant difference (p < 0.001 from two-tailed paired t-test). The method was also validated using depth maps constructed from stereo fundus photographs of the optic nerve head, which were compared to the flattened top surface from the OCT datasets. Significant differences (p < 0.001) were noted between the artifact-corrected datasets and the original datasets, where the mean unsigned differences computed over 30 optic-nerve-head-centered scans (in normalized units) were 0.134 ± 0.035 and 0.302 ± 0.134, respectively. PMID:21833377

  5. Assessment of metal artifact reduction methods in pelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Abdoli, Mehrsima [Department of Radiation Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, Amsterdam 1066 CX (Netherlands); Mehranian, Abolfazl [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva CH-1211 (Switzerland); Ailianou, Angeliki; Becker, Minerva [Division of Radiology, Geneva University Hospital, Geneva CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva CH-1211 (Switzerland); Geneva Neuroscience Center, Geneva University, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, Groningen 9700 RB (Netherlands)

    2016-04-15

    Purpose: Metal artifact reduction (MAR) produces images with improved quality potentially leading to confident and reliable clinical diagnosis and therapy planning. In this work, the authors evaluate the performance of five MAR techniques for the assessment of computed tomography images of patients with hip prostheses. Methods: Five MAR algorithms were evaluated using simulation and clinical studies. The algorithms included one-dimensional linear interpolation (LI) of the corrupted projection bins in the sinogram, two-dimensional interpolation (2D), a normalized metal artifact reduction (NMAR) technique, a metal deletion technique, and a maximum a posteriori completion (MAPC) approach. The algorithms were applied to ten simulated datasets as well as 30 clinical studies of patients with metallic hip implants. Qualitative evaluations were performed by two blinded experienced radiologists who ranked overall artifact severity and pelvic organ recognition for each algorithm by assigning scores from zero to five (zero indicating totally obscured organs with no structures identifiable and five indicating recognition with high confidence). Results: Simulation studies revealed that 2D, NMAR, and MAPC techniques performed almost equally well in all regions. LI falls behind the other approaches in terms of reducing dark streaking artifacts as well as preserving unaffected regions (p < 0.05). Visual assessment of clinical datasets revealed the superiority of NMAR and MAPC in the evaluated pelvic organs and in terms of overall image quality. Conclusions: Overall, all methods, except LI, performed equally well in artifact-free regions. Considering both clinical and simulation studies, 2D, NMAR, and MAPC seem to outperform the other techniques.

  6. A study of metal artifacts on MR imaging. Evaluation of scanning parameters

    International Nuclear Information System (INIS)

    Yamashiro, Mitsuaki

    1999-01-01

    The purpose of this study was to evaluate scanning parameters on MR imaging for reducing metal artifacts using phantom study. Metal artifacts on sagittal images, perpendicular to static magnetic direction showed round shape in the relationship between shape of metal artifacts on MR images and scanning direction. Metal artifacts on both axial and coronal images, parallel to static magnetic direction showed oval shape in the direction of X-axis. In spin echo sequences, the largest dimension of metal artifacts was coronal image, followed by axial image and then sagittal image. In gradient echo sequences, the largest dimension of metal artifacts was axial image, followed by coronal image and then sagittal image. The best scanning plane for reducing metal artifacts was perpendicular to static magnetic direction. In scanning sequences, the largest dimensions of metal artifacts were gradient echo sequences, followed by T2-weighted spin echo sequence and then proton density-weighted and T1-weighted spin echo sequences. Large flip angle increased much metal artifacts on both axial and coronal images in gradient echo sequences. Small flip angle was useful for reducing metal artifacts on both axial and coronal images. The influence of flip angle on metal artifacts in sagittal images perpendicular static magnetic direction was less than for images in coronal and axial planes on gradient echo sequences. These results suggested that a study of metal artifacts on MR imaging about evaluation of scanning parameters was useful to reduce metal artifacts on MR images. (K.H.)

  7. The perception of object versus objectless motion.

    Science.gov (United States)

    Hock, Howard S; Nichols, David F

    2013-05-01

    Wertheimer, M. (Zeitschrift für Psychologie und Physiologie der Sinnesorgane, 61:161-265, 1912) classical distinction between beta (object) and phi (objectless) motion is elaborated here in a series of experiments concerning competition between two qualitatively different motion percepts, induced by sequential changes in luminance for two-dimensional geometric objects composed of rectangular surfaces. One of these percepts is of spreading-luminance motion that continuously sweeps across the entire object; it exhibits shape invariance and is perceived most strongly for fast speeds. Significantly for the characterization of phi as objectless motion, the spreading luminance does not involve surface boundaries or any other feature; the percept is driven solely by spatiotemporal changes in luminance. Alternatively, and for relatively slow speeds, a discrete series of edge motions can be perceived in the direction opposite to spreading-luminance motion. Akin to beta motion, the edges appear to move through intermediate positions within the object's changing surfaces. Significantly for the characterization of beta as object motion, edge motion exhibits shape dependence and is based on the detection of oppositely signed changes in contrast (i.e., counterchange) for features essential to the determination of an object's shape, the boundaries separating its surfaces. These results are consistent with area MT neurons that differ with respect to speed preference Newsome et al (Journal of Neurophysiology, 55:1340-1351, 1986) and shape dependence Zeki (Journal of Physiology, 236:549-573, 1974).

  8. Correction of patient motion in cone-beam CT using 3D-2D registration

    Science.gov (United States)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-12-01

    Cone-beam CT (CBCT) is increasingly common in guidance of interventional procedures, but can be subject to artifacts arising from patient motion during fairly long (~5-60 s) scan times. We present a fiducial-free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in the intrinsic and extrinsic parameters of geometric calibration. The 3D-2D registration process registers each projection to a prior 3D image by maximizing gradient orientation using the covariance matrix adaptation-evolution strategy optimizer. The resulting rigid transforms are applied to the system projection matrices, and a 3D image is reconstructed via model-based iterative reconstruction. Phantom experiments were conducted using a Zeego robotic C-arm to image a head phantom undergoing 5-15 cm translations and 5-15° rotations. To further test the algorithm, clinical images were acquired with a CBCT head scanner in which long scan times were susceptible to significant patient motion. CBCT images were reconstructed using a penalized likelihood objective function. For phantom studies the structural similarity (SSIM) between motion-free and motion-corrected images was  >0.995, with significant improvement (p  values of uncorrected images. Additionally, motion-corrected images exhibited a point-spread function with full-width at half maximum comparable to that of the motion-free reference image. Qualitative comparison of the motion-corrupted and motion-corrected clinical images demonstrated a significant improvement in image quality after motion correction. This indicates that the 3D-2D registration method could provide a useful approach to motion artifact correction under assumptions of local rigidity, as in the head, pelvis, and extremities. The method is highly parallelizable, and the automatic correction of residual geometric calibration errors provides added benefit that could be valuable in routine use.

  9. Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography

    Czech Academy of Sciences Publication Activity Database

    Michálek, Jan

    2015-01-01

    Roč. 21, č. 6 (2015), s. 1602-1615 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LH13028; GA ČR(CZ) GA13-12412S Institutional support: RVO:67985823 Keywords : optical projection tomography * microscopy * artifacts * total variation * data mismatch Subject RIV: EA - Cell Biology Impact factor: 1.730, year: 2015

  10. When fast atom diffraction turns 3D

    International Nuclear Information System (INIS)

    Zugarramurdi, Asier; Borisov, Andrei G.

    2013-01-01

    Fast atom diffraction at surfaces (FAD) in grazing incidence geometry is characterized by the slow motion in the direction perpendicular to the surface and fast motion parallel to the surface plane along a low index direction. It is established experimentally that for the typical surfaces the FAD reveals the 2D diffraction patterns associated with exchange of the reciprocal lattice vector perpendicular to the direction of fast motion. The reciprocal lattice vector exchange along the direction of fast motion is negligible. The usual approximation made in the description of the experimental data is then to assume that the effective potential leading to the diffraction results from the averaging of the 3D surface potential along the atomic strings forming the axial channel. In this work we use full quantum wave packet propagation calculations to study theoretically the possibility to observe the 3D diffraction in FAD experiments. We show that for the surfaces with large unit cell, such as can be the case for reconstructed or vicinal surfaces, the 3D diffraction can be observed. The reciprocal lattice vector exchange along the direction of fast motion leads to several Laue circles in the diffraction pattern

  11. A Preliminary Verification and Validation (V and V) Methodology for the Artifacts Programmed with a Hardware Description Language (HDL)

    International Nuclear Information System (INIS)

    Suh, Yong Suk; Keum, Jong Yong; Park, Je Youn; Jo, Ki Ho; Jo, Chang Whan

    2008-01-01

    Nowadays, the FPGA (Field Programmable Gate Array) is widely used in various fields of industry. The FPGA was evolved from the technology of PLD (Programmable Logic Device). The FPGA provides more logic gates than the PLD, which integrates millions of programmable logic gates into a chip. It also provides a massive, fast and reliable processing performance. So, we can integrate a system's functions into a FPGA, which can be a SoC (System on Chip). Furthermore, we can make a FPGA-based DSP, which DSP functions are implemented with a FPGA. With these merits, the FPGA is also used in the nuclear industry. For example, the safety-critical I and C component is manufactured with the FPGA. The FPGA is programmed with a HDL. The quality of the artifacts programmed with a HDL can impact on the quality of a FPGA. When a hazard fault exists in the artifact of a FPGA and is activated during its operation, an accident caused by the fault in the FPGA occurs. So, it is necessary to ensure the quality of the artifacts. This paper, for the purpose of applying it to the SMART (System-integrated Modular Advanced ReacTor) MMIS project, is to present a preliminary V and V methodology for HDL programmed artifacts. For this, we reviewed the following items: - Characteristics of HDL programming - Applicable requirements for a HDL program used for the safety-critical systems - Fault modes of a FPGA Based on the review, we establish the preliminary V and V methodology

  12. The effects of breathing motion on DCE-MRI images: Phantom studies simulating respiratory motion to compare CAIPARINHA-VIBE, radial VIBE, and conventional VIBE

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Kyung; Seo, Nieun; Kim, Bohyun; Huh, Jimi; Kim, Jeong Kon; Lee, Seung Soo; KIm, Kyung Won [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, In Seong [Siemens Healthcare Korea, Seoul (Korea, Republic of); Nickel, Dominik [MR Application Predevelopment, Siemens Healthcare, Erlangen (Germany)

    2017-04-15

    To compare the breathing effects on dynamic contrast-enhanced (DCE)-MRI between controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE), radial VIBE with k-space-weighted image contrast view-sharing (radial-VIBE), and conventional VIBE (c-VIBE) sequences using a dedicated phantom experiment. We developed a moving platform to simulate breathing motion. We conducted dynamic scanning on a 3T machine (MAGNETOM Skyra, Siemens Healthcare) using CAIPIRINHA-VIBE, radial-VIBE, and c-VIBE for six minutes per sequence. We acquired MRI images of the phantom in both static and moving modes, and we also obtained motion-corrected images for the motion mode. We compared the signal stability and signal-to-noise ratio (SNR) of each sequence according to motion state and used the coefficients of variation (CoV) to determine the degree of signal stability. With motion, CAIPIRINHA-VIBE showed the best image quality, and the motion correction aligned the images very well. The CoV (%) of CAIPIRINHA-VIBE in the moving mode (18.65) decreased significantly after the motion correction (2.56) (p < 0.001). In contrast, c-VIBE showed severe breathing motion artifacts that did not improve after motion correction. For radial-VIBE, the position of the phantom in the images did not change during motion, but streak artifacts significantly degraded image quality, also after motion correction. In addition, SNR increased in both CAIPIRINHA-VIBE (from 3.37 to 9.41, p < 0.001) and radial-VIBE (from 4.3 to 4.96, p < 0.001) after motion correction. CAIPIRINHA-VIBE performed best for free-breathing DCE-MRI after motion correction, with excellent image quality.

  13. Measuring Motion-Induced B0-Fluctuations in the Brain Using Field Probes

    DEFF Research Database (Denmark)

    Andersen, Mads; Hanson, Lars G.; Madsen, Kristoffer Hougaard

    2016-01-01

    Purpose: Fluctuations of the background magnetic field (B0) due to body and breathing motion can lead to significant artifacts in brain imaging at ultrahigh field. Corrections based on real-time sensing using external field probes show great potential. This study evaluates different aspects of fi...

  14. Identification of a unique cause of ring artifact seen in computed tomography trans-axial images

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar; Purandare, Nilendu C; Shah, Sneha; Agrawal, Archi; Puranik, Ameya D; Rangarajan, Venkatesh

    2013-01-01

    Artifacts present in computed tomography (CT) image often degrade the image quality and ultimately, the diagnostic outcome. Ring artifact in trans-axial image is caused by either miscalibrated or defective detector element of detector row, which is often categorized as scanner based artifact. A ring artifact detected on trans-axial CT image of positron emission tomography/computed tomography (PET/CT), was caused by contamination of CT tube aperture by droplet of injectable contrast medium. This artifact was corrected by removal of contrast droplet from CT tube aperture. The ring artifact is a very common artifact, commonly cited in the literature. Our case puts forward an uncommon cause of this artifact and its method of correction, which also, has no mention in the existing literature

  15. Separating complex compound patient motion tracking data using independent component analysis

    Science.gov (United States)

    Lindsay, C.; Johnson, K.; King, M. A.

    2014-03-01

    In SPECT imaging, motion from respiration and body motion can reduce image quality by introducing motion-related artifacts. A minimally-invasive way to track patient motion is to attach external markers to the patient's body and record their location throughout the imaging study. If a patient exhibits multiple movements simultaneously, such as respiration and body-movement, each marker location data will contain a mixture of these motions. Decomposing this complex compound motion into separate simplified motions can have the benefit of applying a more robust motion correction to the specific type of motion. Most motion tracking and correction techniques target a single type of motion and either ignore compound motion or treat it as noise. Few methods account for compound motion exist, but they fail to disambiguate super-position in the compound motion (i.e. inspiration in addition to body movement in the positive anterior/posterior direction). We propose a new method for decomposing the complex compound patient motion using an unsupervised learning technique called Independent Component Analysis (ICA). Our method can automatically detect and separate different motions while preserving nuanced features of the motion without the drawbacks of previous methods. Our main contributions are the development of a method for addressing multiple compound motions, the novel use of ICA in detecting and separating mixed independent motions, and generating motion transform with 12 DOFs to account for twisting and shearing. We show that our method works with clinical datasets and can be employed to improve motion correction in single photon emission computed tomography (SPECT) images.

  16. General rigid motion correction for computed tomography imaging based on locally linear embedding

    Science.gov (United States)

    Chen, Mianyi; He, Peng; Feng, Peng; Liu, Baodong; Yang, Qingsong; Wei, Biao; Wang, Ge

    2018-02-01

    The patient motion can damage the quality of computed tomography images, which are typically acquired in cone-beam geometry. The rigid patient motion is characterized by six geometric parameters and are more challenging to correct than in fan-beam geometry. We extend our previous rigid patient motion correction method based on the principle of locally linear embedding (LLE) from fan-beam to cone-beam geometry and accelerate the computational procedure with the graphics processing unit (GPU)-based all scale tomographic reconstruction Antwerp toolbox. The major merit of our method is that we need neither fiducial markers nor motion-tracking devices. The numerical and experimental studies show that the LLE-based patient motion correction is capable of calibrating the six parameters of the patient motion simultaneously, reducing patient motion artifacts significantly.

  17. Content Adaptive True Motion Estimator for H.264 Video Compression

    Directory of Open Access Journals (Sweden)

    P. Kulla

    2007-12-01

    Full Text Available Content adaptive true motion estimator for H.264 video coding is a fast block-based matching estimator with implemented multi-stage approach to estimate motion fields between two image frames. It considers the theory of 3D scene objects projection into 2D image plane for selection of motion vector candidates from the higher stages. The stages of the algorithm and its hierarchy are defined upon motion estimation reliability measurement (image blocks including two different directions of spatial gradient, blocks with one dominant spatial gradient and blocks including minimal spatial gradient. Parameters of the image classification into stages are set adaptively upon image structure. Due to search strategy are the estimated motion fields more corresponding to a true motion in an image sequence as in the case of conventional motion estimation algorithms that use fixed sets of motion vector candidates from tight neighborhood.

  18. A New Approach for Automatic Removal of Movement Artifacts in Near-Infrared Spectroscopy Time Series by Means of Acceleration Data

    Directory of Open Access Journals (Sweden)

    Andreas Jaakko Metz

    2015-11-01

    Full Text Available Near-infrared spectroscopy (NIRS enables the non-invasive measurement of changes in hemodynamics and oxygenation in tissue. Changes in light-coupling due to movement of the subject can cause movement artifacts (MAs in the recorded signals. Several methods have been developed so far that facilitate the detection and reduction of MAs in the data. However, due to fixed parameter values (e.g., global threshold none of these methods are perfectly suitable for long-term (i.e., hours recordings or were not time-effective when applied to large datasets. We aimed to overcome these limitations by automation, i.e., data adaptive thresholding specifically designed for long-term measurements, and by introducing a stable long-term signal reconstruction. Our new technique (“acceleration-based movement artifact reduction algorithm”, AMARA is based on combining two methods: the “movement artifact reduction algorithm” (MARA, Scholkmann et al. Phys. Meas. 2010, 31, 649–662, and the “accelerometer-based motion artifact removal” (ABAMAR, Virtanen et al. J. Biomed. Opt. 2011, 16, 087005. We describe AMARA in detail and report about successful validation of the algorithm using empirical NIRS data, measured over the prefrontal cortex in adolescents during sleep. In addition, we compared the performance of AMARA to that of MARA and ABAMAR based on validation data.

  19. A dialectical take on artifact ecologies and the physical - digital divide

    DEFF Research Database (Denmark)

    Bødker, Susanne; Klokmose, Clemens Nylandsted

    In this position paper, we will present and discuss our understanding of artifact ecologies as we have developed it, rooted in activity theoretical HCI and dialectical thinking . Our basis is in the Human-Artifact Model, as well as well as cases where we have worked with artifact ecologies...

  20. Prospective motion correction with volumetric navigators (vNavs) reduces the bias and variance in brain morphometry induced by subject motion.

    Science.gov (United States)

    Tisdall, M Dylan; Reuter, Martin; Qureshi, Abid; Buckner, Randy L; Fischl, Bruce; van der Kouwe, André J W

    2016-02-15

    Recent work has demonstrated that subject motion produces systematic biases in the metrics computed by widely used morphometry software packages, even when the motion is too small to produce noticeable image artifacts. In the common situation where the control population exhibits different behaviors in the scanner when compared to the experimental population, these systematic measurement biases may produce significant confounds for between-group analyses, leading to erroneous conclusions about group differences. While previous work has shown that prospective motion correction can improve perceived image quality, here we demonstrate that, in healthy subjects performing a variety of directed motions, the use of the volumetric navigator (vNav) prospective motion correction system significantly reduces the motion-induced bias and variance in morphometry. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Fast reactors

    International Nuclear Information System (INIS)

    Vasile, A.

    2001-01-01

    Fast reactors have capacities to spare uranium natural resources by their breeding property and to propose solutions to the management of radioactive wastes by limiting the inventory of heavy nuclei. This article highlights the role that fast reactors could play for reducing the radiotoxicity of wastes. The conversion of 238 U into 239 Pu by neutron capture is more efficient in fast reactors than in light water reactors. In fast reactors multi-recycling of U + Pu leads to fissioning up to 95% of the initial fuel ( 238 U + 235 U). 2 strategies have been studied to burn actinides: - the multi-recycling of heavy nuclei is made inside the fuel element (homogeneous option); - the unique recycling is made in special irradiation targets placed inside the core or at its surroundings (heterogeneous option). Simulations have shown that, for the same amount of energy produced (400 TWhe), the mass of transuranium elements (Pu + Np + Am + Cm) sent to waste disposal is 60,9 Kg in the homogeneous option and 204.4 Kg in the heterogeneous option. Experimental programs are carried out in Phenix and BOR60 reactors in order to study the feasibility of such strategies. (A.C.)

  2. Fast ejendom

    DEFF Research Database (Denmark)

    Pagh, Peter

    Bogen omfatter en gennemgang af lovgivning, praksis og teori vedrørende køb af fast ejendom og offentligretlig og privatretlig regulering. Bogen belyser bl.a. de privatretlige emner: købers misligholdelsesbeføjelser, servitutter, naboret, hævd og erstatningsansvar for miljøskader samt den...

  3. Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model.

    Science.gov (United States)

    Marx, Mirko; Ehrhardt, Jan; Werner, René; Schlemmer, Heinz-Peter; Handels, Heinz

    2014-05-01

    Four-dimensional CT imaging is widely used to account for motion-related effects during radiotherapy planning of lung cancer patients. However, 4D CT often contains motion artifacts, cannot be used to measure motion variability, and leads to higher dose exposure. In this article, we propose using 4D MRI to acquire motion information for the radiotherapy planning process. From the 4D MRI images, we derive a time-continuous model of the average patient-specific respiratory motion, which is then applied to simulate 4D CT data based on a static 3D CT. The idea of the motion model is to represent the average lung motion over a respiratory cycle by cyclic B-spline curves. The model generation consists of motion field estimation in the 4D MRI data by nonlinear registration, assigning respiratory phases to the motion fields, and applying a B-spline approximation on a voxel-by-voxel basis to describe the average voxel motion over a breathing cycle. To simulate a patient-specific 4D CT based on a static CT of the patient, a multi-modal registration strategy is introduced to transfer the motion model from MRI to the static CT coordinates. Differences between model-based estimated and measured motion vectors are on average 1.39 mm for amplitude-based binning of the 4D MRI data of three patients. In addition, the MRI-to-CT registration strategy is shown to be suitable for the model transformation. The application of our 4D MRI-based motion model for simulating 4D CT images provides advantages over standard 4D CT (less motion artifacts, radiation-free). This makes it interesting for radiotherapy planning.

  4. TH-C-BRD-06: A Novel MRI Based CT Artifact Correction Method for Improving Proton Range Calculation in the Presence of Severe CT Artifacts

    International Nuclear Information System (INIS)

    Park, P; Schreibmann, E; Fox, T; Roper, J; Elder, E; Tejani, M; Crocker, I; Curran, W; Dhabaan, A

    2014-01-01

    Purpose: Severe CT artifacts can impair our ability to accurately calculate proton range thereby resulting in a clinically unacceptable treatment plan. In this work, we investigated a novel CT artifact correction method based on a coregistered MRI and investigated its ability to estimate CT HU and proton range in the presence of severe CT artifacts. Methods: The proposed method corrects corrupted CT data using a coregistered MRI to guide the mapping of CT values from a nearby artifact-free region. First patient MRI and CT images were registered using 3D deformable image registration software based on B-spline and mutual information. The CT slice with severe artifacts was selected as well as a nearby slice free of artifacts (e.g. 1cm away from the artifact). The two sets of paired MRI and CT images at different slice locations were further registered by applying 2D deformable image registration. Based on the artifact free paired MRI and CT images, a comprehensive geospatial analysis was performed to predict the correct CT HU of the CT image with severe artifact. For a proof of concept, a known artifact was introduced that changed the ground truth CT HU value up to 30% and up to 5cm error in proton range. The ability of the proposed method to recover the ground truth was quantified using a selected head and neck case. Results: A significant improvement in image quality was observed visually. Our proof of concept study showed that 90% of area that had 30% errors in CT HU was corrected to 3% of its ground truth value. Furthermore, the maximum proton range error up to 5cm was reduced to 4mm error. Conclusion: MRI based CT artifact correction method can improve CT image quality and proton range calculation for patients with severe CT artifacts

  5. Discriminative Vision-Based Recovery and Recognition of Human Motion

    NARCIS (Netherlands)

    Poppe, Ronald Walter

    2009-01-01

    The automatic analysis of human motion from images opens up the way for applications in the domains of security and surveillance, human-computer interaction, animation, retrieval and sports motion analysis. In this dissertation, the focus is on robust and fast human pose recovery and action

  6. Coulomb artifacts and bottomonium hyperfine splitting in lattice NRQCD

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T. [Department of Physics, University of Alberta,11455 Saskatchewan Drive, Edmonton, Alberta T6G 2J1 (Canada); Penin, A.A. [Department of Physics, University of Alberta,11455 Saskatchewan Drive, Edmonton, Alberta T6G 2J1 (Canada); Institut für Theoretische Teilchenphysik, Karlsruhe Institute of Technology,Wolfgang-Gaede-Strasse 1, 76128 Karlsruhe (Germany); Rayyan, A. [Department of Physics, University of Alberta,11455 Saskatchewan Drive, Edmonton, Alberta T6G 2J1 (Canada)

    2017-02-16

    We study the role of the lattice artifacts associated with the Coulomb binding effects in the analysis of the heavy quarkonium within lattice NRQCD. We find that a “naïve” perturbative matching generates spurious linear Coulomb artifacts, which result in a large systematic error in the lattice predictions for the heavy quarkonium spectrum. This effect is responsible, in particular, for the discrepancy between the recent determinations of the bottomonium hyperfine splitting in the radiatively improved lattice NRQCD (DOI: 10.1103/PhysRevD.92.054502; Arxiv:1309.5797). We show that the correct matching procedure which provides full control over discretization errors is based on the asymptotic expansion of the lattice theory about the continuum limit, which gives M{sub Υ(1S)}−M{sub η{sub b(1S)}}=52.9±5.5 MeV (DOI: 10.1103/PhysRevD.92.054502).

  7. Santeria and Palo Mayombe: skulls, mercury, and artifacts.

    Science.gov (United States)

    Gill, James R; Rainwater, Christopher W; Adams, Bradley J

    2009-11-01

    Santeria and Palo Mayombe are syncretic religions created in the New World based upon African religious beliefs combined with Christianity. The main worship of Palo Mayombe involves religious receptacles that may contain earth, sticks, varied artifacts, and animal and human remains. Due to the use of human and nonhuman remains, discovery of these items often leads to involvement by the police due to a concern of homicide. We review in detail the medical examiner records of two of these ritualistic cases including the autopsy, anthropology, police, and investigators' reports. For the human remains, careful consideration of the context in which the remains were recovered, their state of preservation, and the associated artifacts (e.g., beads and mercury) are important in determining the appropriate level of forensic significance. Anthropological examination with particular attention to taphonomic characteristics also may help determine the origin and forensic significance.

  8. Inter-deriving Semantic Artifacts for Object-Oriented Programming

    DEFF Research Database (Denmark)

    Danvy, Olivier; Johannsen, Jacob

    2008-01-01

    .e., big-step operational semantics) specified in Abadi and Cardelli's monograph. This abstract machine therefore embodies the soundness of Abadi and Cardelli's reduction semantics and natural semantics relative to each other. To move closer to actual implementations, which use environments rather than......We present a new abstract machine for Abadi and Cardelli's untyped calculus of objects. What is special about this semantic artifact (i.e., man-made construct) is that is mechanically corresponds to both the reduction semantics (i.e., small-step operational semantics) and the natural semantics (i...... actual substitutions, we then represent object methods as closures and in the same inter-derivational spirit, we present three new semantic artifacts: a reduction semantics for a version of Abadi and Cardelli's untyped calculus of objects with explicit substitutions, an environment-based abstract machine...

  9. Interpolation strategies for reducing IFOV artifacts in microgrid polarimeter imagery.

    Science.gov (United States)

    Ratliff, Bradley M; LaCasse, Charles F; Tyo, J Scott

    2009-05-25

    Microgrid polarimeters are composed of an array of micro-polarizing elements overlaid upon an FPA sensor. In the past decade systems have been designed and built in all regions of the optical spectrum. These systems have rugged, compact designs and the ability to obtain a complete set of polarimetric measurements during a single image capture. However, these systems acquire the polarization measurements through spatial modulation and each measurement has a varying instantaneous field-of-view (IFOV). When these measurements are combined to estimate the polarization images, strong edge artifacts are present that severely degrade the estimated polarization imagery. These artifacts can be reduced when interpolation strategies are first applied to the intensity data prior to Stokes vector estimation. Here we formally study IFOV error and the performance of several bilinear interpolation strategies used for reducing it.

  10. A system for learning statistical motion patterns.

    Science.gov (United States)

    Hu, Weiming; Xiao, Xuejuan; Fu, Zhouyu; Xie, Dan; Tan, Tieniu; Maybank, Steve

    2006-09-01

    Analysis of motion patterns is an effective approach for anomaly detection and behavior prediction. Current approaches for the analysis of motion patterns depend on known scenes, where objects move in predefined ways. It is highly desirable to automatically construct object motion patterns which reflect the knowledge of the scene. In this paper, we present a system for automatically learning motion patterns for anomaly detection and behavior prediction based on a proposed algorithm for robustly tracking multiple objects. In the tracking algorithm, foreground pixels are clustered using a fast accurate fuzzy K-means algorithm. Growing and prediction of the cluster centroids of foreground pixels ensure that each cluster centroid is associated with a moving object in the scene. In the algorithm for learning motion patterns, trajectories are clustered hierarchically using spatial and temporal information and then each motion pattern is represented with a chain of Gaussian distributions. Based on the learned statistical motion patterns, statistical methods are used to detect anomalies and predict behaviors. Our system is tested using image sequences acquired, respectively, from a crowded real traffic scene and a model traffic scene. Experimental results show the robustness of the tracking algorithm, the efficiency of the algorithm for learning motion patterns, and the encouraging performance of algorithms for anomaly detection and behavior prediction.

  11. Essential Layers, Artifacts, and Dependencies of Enterprise Architecture

    OpenAIRE

    Winter, Robert; Fischer, Ronny

    2007-01-01

    After a period where implementation speed was more important than integration, consistency and reduction of complexity, architectural considerations have become a key issue of information management in recent years again. Enterprise architecture is widely accepted as an essential mechanism for ensuring agility and consistency, compliance and efficiency. Although standards like TOGAF and FEAF have developed, however, there is no common agreement on which architecture layers, which artifact typ...

  12. An Improved Method to Watermark Images Sensitive to Blocking Artifacts

    OpenAIRE

    Afzel Noore

    2007-01-01

    A new digital watermarking technique for images that are sensitive to blocking artifacts is presented. Experimental results show that the proposed MDCT based approach produces highly imperceptible watermarked images and is robust to attacks such as compression, noise, filtering and geometric transformations. The proposed MDCT watermarking technique is applied to fingerprints for ensuring security. The face image and demographic text data of an individual are used as multi...

  13. Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging

    International Nuclear Information System (INIS)

    Zimel, Melissa N.; Hwang, Sinchun; Riedel, Elyn R.; Healey, John H.

    2015-01-01

    This study assessed whether radiolucent carbon fiber reinforced-polyetheretherketone (CFR-PEEK) intramedullary nails decreased hardware artifact on magnetic resonance imaging (MRI) and computed tomography (CT) in vitro and in an oncologic patient population. In vitro and clinical evaluations were done. A qualitative assessment of metal artifact was performed using CFR-PEEK and titanium nail MRI phantoms. Eight patients with a femoral or tibial prophylactic CFR-PEEK nail were retrospectively identified. All patients had postoperative surveillance imaging by MRI, CT, and were followed for a median 20 months (range, 12-28 months). CFR-PEEK images were compared to images from a comparative group of patients with titanium femoral intramedullary nails who had a postoperative MRI or CT. A musculoskeletal-trained radiologist graded visualization of the cortex, corticomedullary junction, and bone-muscle interface, on T1-weighted (T1W), STIR, and contrast-enhanced T1-weighted fat-saturated (T1W FS) sequences of both groups with a five-point scale, performing independent reviews 4 months apart. Statistical analysis used the Wilcoxon rank-sum test and a weighted kappa. Substantially less MRI signal loss occurred in the CFR-PEEK phantom than in the titanium phantom simulation, particularly as the angle increased with respect to direction of the static magnetic field. CFR-PEEK nails had less MRI artifact than titanium nails on scored T1W, STIR, and contrast-enhanced T1W FS MRI sequences (p ≤ 0.03). The mean weighted kappa was 0.64, showing excellent intraobserver reliability between readings. CFR-PEEK intramedullary nail fixation is a superior alternative to minimize implant artifact on MRI or CT imaging for patients requiring long bone fixation. (orig.)

  14. Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zimel, Melissa N. [Memorial Sloan Kettering Cancer Center, Orthopaedic Surgery Service, Department of Surgery, New York, NY (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Riedel, Elyn R. [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopaedic Surgery Service, Department of Surgery, New York, NY (United States); Weill Medical College of Cornell University, Department of Orthopaedic Surgery, New York, NY (United States)

    2015-09-15

    This study assessed whether radiolucent carbon fiber reinforced-polyetheretherketone (CFR-PEEK) intramedullary nails decreased hardware artifact on magnetic resonance imaging (MRI) and computed tomography (CT) in vitro and in an oncologic patient population. In vitro and clinical evaluations were done. A qualitative assessment of metal artifact was performed using CFR-PEEK and titanium nail MRI phantoms. Eight patients with a femoral or tibial prophylactic CFR-PEEK nail were retrospectively identified. All patients had postoperative surveillance imaging by MRI, CT, and were followed for a median 20 months (range, 12-28 months). CFR-PEEK images were compared to images from a comparative group of patients with titanium femoral intramedullary nails who had a postoperative MRI or CT. A musculoskeletal-trained radiologist graded visualization of the cortex, corticomedullary junction, and bone-muscle interface, on T1-weighted (T1W), STIR, and contrast-enhanced T1-weighted fat-saturated (T1W FS) sequences of both groups with a five-point scale, performing independent reviews 4 months apart. Statistical analysis used the Wilcoxon rank-sum test and a weighted kappa. Substantially less MRI signal loss occurred in the CFR-PEEK phantom than in the titanium phantom simulation, particularly as the angle increased with respect to direction of the static magnetic field. CFR-PEEK nails had less MRI artifact than titanium nails on scored T1W, STIR, and contrast-enhanced T1W FS MRI sequences (p ≤ 0.03). The mean weighted kappa was 0.64, showing excellent intraobserver reliability between readings. CFR-PEEK intramedullary nail fixation is a superior alternative to minimize implant artifact on MRI or CT imaging for patients requiring long bone fixation. (orig.)

  15. Technical artifacts in chromatographic analysis of Tc-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Creekmore, J.R.

    1982-01-01

    Technical artifacts produced during chromatographic analysis of technetium radiopharmaceuticals were investigated. Such artifacts are, we found, caused by improper spotting and drying techniques; these in turn produce spuriously high impurities in Tc-99m complexes of DTPA, MDP, PPi, and GH. The ITLC-SG/acetone system produces considerable streaking of Tc-complex if the applied spot is large and not dried before development. This results in activity in the solvent front portion of the chromatographic strip indicating falsely high levels of pertechnetate impurity. Proper drying of the applied spot eliminates the artifact. The ITLC-SG/saline system yields falsely high, hydrolyzed-reduced technetium impurities if the spot is allowed to enter the solvent during development. Correct spot placement and size eliminate this problem. Strips that are allowed to dry in room air for several minutes may indicate considerable pertechnetate impurity on the chromatogram; yet this may not actually be present in the radiopharmaceutical vial. Drying spots rapidly with hot air or in a nitrogen atmosphere before development eliminates this problem

  16. On removing interpolation and resampling artifacts in rigid image registration.

    Science.gov (United States)

    Aganj, Iman; Yeo, Boon Thye Thomas; Sabuncu, Mert R; Fischl, Bruce

    2013-02-01

    We show that image registration using conventional interpolation and summation approximations of continuous integrals can generally fail because of resampling artifacts. These artifacts negatively affect the accuracy of registration by producing local optima, altering the gradient, shifting the global optimum, and making rigid registration asymmetric. In this paper, after an extensive literature review, we demonstrate the causes of the artifacts by comparing inclusion and avoidance of resampling analytically. We show the sum-of-squared-differences cost function formulated as an integral to be more accurate compared with its traditional sum form in a simple case of image registration. We then discuss aliasing that occurs in rotation, which is due to the fact that an image represented in the Cartesian grid is sampled with different rates in different directions, and propose the use of oscillatory isotropic interpolation kernels, which allow better recovery of true global optima by overcoming this type of aliasing. Through our experiments on brain, fingerprint, and white noise images, we illustrate the superior performance of the integral registration cost function in both the Cartesian and spherical coordinates, and also validate the introduced radial interpolation kernel by demonstrating the improvement in registration.

  17. Reducing Interpolation Artifacts for Mutual Information Based Image Registration

    Science.gov (United States)

    Soleimani, H.; Khosravifard, M.A.

    2011-01-01

    Medical image registration methods which use mutual information as similarity measure have been improved in recent decades. Mutual Information is a basic concept of Information theory which indicates the dependency of two random variables (or two images). In order to evaluate the mutual information of two images their joint probability distribution is required. Several interpolation methods, such as Partial Volume (PV) and bilinear, are used to estimate joint probability distribution. Both of these two methods yield some artifacts on mutual information function. Partial Volume-Hanning window (PVH) and Generalized Partial Volume (GPV) methods are introduced to remove such artifacts. In this paper we show that the acceptable performance of these methods is not due to their kernel function. It's because of the number of pixels which incorporate in interpolation. Since using more pixels requires more complex and time consuming interpolation process, we propose a new interpolation method which uses only four pixels (the same as PV and bilinear interpolations) and removes most of the artifacts. Experimental results of the registration of Computed Tomography (CT) images show superiority of the proposed scheme. PMID:22606673

  18. Trails of meaning construction: Symbolic artifacts engage the social brain.

    Science.gov (United States)

    Tylén, Kristian; Philipsen, Johanne Stege; Roepstorff, Andreas; Fusaroli, Riccardo

    2016-07-01

    Symbolic artifacts present a challenge to theories of neurocognitive processing due to their hybrid nature: they are at the same time physical objects and vehicles of intangible social meanings. While their physical properties can be read of their perceptual appearance, the meaning of symbolic artifacts depends on the perceiver's interpretative attitude and embeddedness in cultural practices. In this study, participants built models of LEGO bricks to illustrate their understanding of abstract concepts. They were then scanned with fMRI while presented to photographs of their own and others' models. When participants attended to the meaning of the models in contrast to their bare physical properties, we observed activations in mPFC and TPJ, areas often associated with social cognition, and IFG, possibly related to semantics. When contrasting own and others' models, we also found activations in precuneus, an area associated with autobiographical memory and agency, while looking at one's own collective models yielded interaction effects in rostral ACC, right IFG and left Insula. Interestingly, variability in the insula was predicted by individual differences in participants' feeling of relatedness to their fellow group members during LEGO construction activity. Our findings support a view of symbolic artifacts as neuro-cognitive trails of human social interactions. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Motion Transplantation Techniques: A Survey

    NARCIS (Netherlands)

    van Basten, Ben; Egges, Arjan

    2012-01-01

    During the past decade, researchers have developed several techniques for transplanting motions. These techniques transplant a partial auxiliary motion, possibly defined for a small set of degrees of freedom, on a base motion. Motion transplantation improves motion databases' expressiveness and

  20. Correction of Bowtie-Filter Normalization and Crescent Artifacts for a Clinical CBCT System.

    Science.gov (United States)

    Zhang, Hong; Kong, Vic; Huang, Ke; Jin, Jian-Yue

    2017-02-01

    To present our experiences in understanding and minimizing bowtie-filter crescent artifacts and bowtie-filter normalization artifacts in a clinical cone beam computed tomography system. Bowtie-filter position and profile variations during gantry rotation were studied. Two previously proposed strategies (A and B) were applied to the clinical cone beam computed tomography system to correct bowtie-filter crescent artifacts. Physical calibration and analytical approaches were used to minimize the norm phantom misalignment and to correct for bowtie-filter normalization artifacts. A combined procedure to reduce bowtie-filter crescent artifacts and bowtie-filter normalization artifacts was proposed and tested on a norm phantom, CatPhan, and a patient and evaluated using standard deviation of Hounsfield unit along a sampling line. The bowtie-filter exhibited not only a translational shift but also an amplitude variation in its projection profile during gantry rotation. Strategy B was better than strategy A slightly in minimizing bowtie-filter crescent artifacts, possibly because it corrected the amplitude variation, suggesting that the amplitude variation plays a role in bowtie-filter crescent artifacts. The physical calibration largely reduced the misalignment-induced bowtie-filter normalization artifacts, and the analytical approach further reduced bowtie-filter normalization artifacts. The combined procedure minimized both bowtie-filter crescent artifacts and bowtie-filter normalization artifacts, with Hounsfield unit standard deviation being 63.2, 45.0, 35.0, and 18.8 Hounsfield unit for the best correction approaches of none, bowtie-filter crescent artifacts, bowtie-filter normalization artifacts, and bowtie-filter normalization artifacts + bowtie-filter crescent artifacts, respectively. The combined procedure also demonstrated reduction of bowtie-filter crescent artifacts and bowtie-filter normalization artifacts in a CatPhan and a patient. We have developed a step

  1. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kajan, Zahra Dalili; Alizadeh, Ahmad; Hemmaty, Yasmin Babael; Roushan, Zahra Atrkar; Khademi, Jalil

    2015-01-01

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires

  2. SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

    International Nuclear Information System (INIS)

    Amro, H; Chetty, I; Gordon, J; Wen, N

    2014-01-01

    Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation

  3. SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

    Energy Technology Data Exchange (ETDEWEB)

    Amro, H; Chetty, I; Gordon, J; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2014-06-01

    Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.

  4. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kajan, Zahra Dalili; Alizadeh, Ahmad; Hemmaty, Yasmin Babael; Roushan, Zahra Atrkar; Khademi, Jalil [Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2015-09-15

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

  5. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging.

    Science.gov (United States)

    Dalili Kajan, Zahra; Khademi, Jalil; Alizadeh, Ahmad; Babaei Hemmaty, Yasamin; Atrkar Roushan, Zahra

    2015-09-01

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1 -weighted images, fast spin-echo T2 -weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

  6. Metal-induced streak artifact reduction using iterative reconstruction algorithms in x-ray computed tomography image of the dentoalveolar region.

    Science.gov (United States)

    Dong, Jian; Hayakawa, Yoshihiko; Kannenberg, Sven; Kober, Cornelia

    2013-02-01

    The objective of this study was to reduce metal-induced streak artifact on oral and maxillofacial x-ray computed tomography (CT) images by developing the fast statistical image reconstruction system using iterative reconstruction algorithms. Adjacent CT images often depict similar anatomical structures in thin slices. So, first, images were reconstructed using the same projection data of an artifact-free image. Second, images were processed by the successive iterative restoration method where projection data were generated from reconstructed image in sequence. Besides the maximum likelihood-expectation maximization algorithm, the ordered subset-expectation maximization algorithm (OS-EM) was examined. Also, small region of interest (ROI) setting and reverse processing were applied for improving performance. Both algorithms reduced artifacts instead of slightly decreasing gray levels. The OS-EM and small ROI reduced the processing duration without apparent detriments. Sequential and reverse processing did not show apparent effects. Two alternatives in iterative reconstruction methods were effective for artifact reduction. The OS-EM algorithm and small ROI setting improved the performance. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Usefulness of IDEAL T2-weighted FSE and SPGR imaging in reducing metallic artifacts in the postoperative ankles with metallic hardware

    International Nuclear Information System (INIS)

    Lee, Jung Bin; Cha, Jang Gyu; Lee, Min Hee; Lee, Eun Hye; Lee, Young Koo; Jeon, Chan Hong

    2013-01-01

    The aim of this work is to prospectively compare the effectiveness of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL), T2-weighted fast spin-echo (FSE), and spoiled gradient-echo (SPGR) MR imaging to frequency selective fat suppression (FSFS) protocols for minimizing metallic artifacts in postoperative ankles with metallic hardware. The T2-weighted and SPGR imaging with IDEAL and FSFS were performed on 21 ankles of 21 patients with metallic hardware. Two musculoskeletal radiologists independently analyzed techniques for visualization of ankle ligaments and articular cartilage, uniformity of fat saturation, and relative size of the metallic artifacts. A paired t test was used for statistical comparisons of MR images between IDEAL and FSFS groups. IDEAL T2-weighted FSE and SPGR images enabled significantly improved visualization of articular cartilage (p < 0.05), the size of metallic artifact (p < 0.05), and the uniformity of fat saturation (p < 0.05). However, no significant improvement was found in the visibility of ligaments. IDEAL T2-weighted FSE and SPGR imaging effectively reduces the degree of tissue-obscuring artifacts produced by fixation hardware in ankle joints and improves image quality compared to FSFS T2-weighted FSE and SPGR imaging. However, visibility of ligaments was not improved using IDEAL imaging. (orig.)

  8. Infrared wireless data transfer for real-time motion control

    NARCIS (Netherlands)

    Gajdusek, M.; Overboom, T.T.; Damen, A.A.H.; Bosch, van den P.P.J.

    2009-01-01

    In this paper several wireless solution are compared for their suitability for real-time control of a fast motion system. From the comparison, Very Fast Infrared (VFIR) communication link has been found to be an attractive solution for presented wirelessly controlled manipulator. Because standard

  9. Metal Artifact Suppression in Dental Cone Beam Computed Tomography Images Using Image Processing Techniques.

    Science.gov (United States)

    Johari, Masoumeh; Abdollahzadeh, Milad; Esmaeili, Farzad; Sakhamanesh, Vahideh

    2018-01-01

    Dental cone beam computed tomography (CBCT) images suffer from severe metal artifacts. These artifacts degrade the quality of acquired image and in some cases make it unsuitable to use. Streaking artifacts and cavities around teeth are the main reason of degradation. In this article, we have proposed a new artifact reduction algorithm which has three parallel components. The first component extracts teeth based on the modeling of image histogram with a Gaussian mixture model. Striking artifact reduction component reduces artifacts using converting image into the polar domain and applying morphological filtering. The third component fills cavities through a simple but effective morphological filtering operation. Finally, results of these three components are combined into a fusion step to create a visually good image which is more compatible to human visual system. Results show that the proposed algorithm reduces artifacts of dental CBCT images and produces clean images.

  10. The role of human ventral visual cortex in motion perception

    Science.gov (United States)

    Saygin, Ayse P.; Lorenzi, Lauren J.; Egan, Ryan; Rees, Geraint; Behrmann, Marlene

    2013-01-01

    Visual motion perception is fundamental to many aspects of visual perception. Visual motion perception has long been associated with the dorsal (parietal) pathway and the involvement of the ventral ‘form’ (temporal) visual pathway has not been considered critical for normal motion perception. Here, we evaluated this view by examining whether circumscribed damage to ventral visual cortex impaired motion perception. The perception of motion in basic, non-form tasks (motion coherence and motion detection) and complex structure-from-motion, for a wide range of motion speeds, all centrally displayed, was assessed in five patients with a circumscribed lesion to either the right or left ventral visual pathway. Patients with a right, but not with a left, ventral visual lesion displayed widespread impairments in central motion perception even for non-form motion, for both slow and for fast speeds, and this held true independent of the integrity of areas MT/V5, V3A or parietal regions. In contrast with the traditional view in which only the dorsal visual stream is critical for motion perception, these novel findings implicate a more distributed circuit in which the integrity of the right ventral visual pathway is also necessary even for the perception of non-form motion. PMID:23983030

  11. MOTION MODELLINGUSINGCONCEPTS OF FUZZY ARTIFICIAL POTENTIAL FIELDS

    Directory of Open Access Journals (Sweden)

    O. Motlagh

    2010-12-01

    Full Text Available Artificial potential fields (APF are well established for reactive navigation of mobile robots. This paper describes a fast and robust fuzzy-APF on an ActivMedia AmigoBot. Obstacle-related information is fuzzified by using sensory fusion, which results in a shorter runtime. In addition, the membership functions of obstacle direction and range have been merged into one function, obtaining a smaller block of rules. The system is tested in virtual environments with non-concave obstacles. Then, the paper describes a new approach to motion modelling where the motion of intelligent travellers is modelled by consecutive path segments. In previous work, the authors described a reliable motion modelling technique using causal inference of fuzzy cognitive maps (FCM which has been efficiently modified for the purpose of this contribution. Results and analysis are given to demonstrate the efficiency and accuracy of the proposed motion modelling algorithm.

  12. PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections.

    Science.gov (United States)

    Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas

    2017-12-01

    Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.

  13. Motion-robust diffusion tensor acquisition at routine 3T magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yasmin, Hasina; Abe, Osamu; Masutani, Yoshitaka; Hayashi, Naoto; Ohtomo, Kuni; Kabasawa, Hiroyuki; Aoki, Shigeki

    2010-01-01

    We compared different acquisition and reconstruction methods in phantom and human studies in the clinical setting to validate our hypothesis that optimizing the k-space acquisition and reconstruction method could decrease motion artifacts. Diffusion tensor images of a water phantom were obtained with three table displacement magnitudes: 1 mm, 2 mm, and 3 mm. Images were reconstructed using homodyne and zero-fill reconstruction. Overscanning in 8- and 16-k y lines was tested. We performed visual assessment of the artifacts using reconstructed coronal images and analyzed them with Wilcoxon signed-ranks test both for phantom and human studies. Also, fractional anisotropy (FA) changes between acquisition methods were compared. Artifacts due to smaller displacement (1 and 2 mm) were significantly reduced in 16-k y overscan with zero filling. The Wilcoxon signed-ranks test showed significant differences (P<0.031 for reconstruction methods and P<0.016 for overscanning methods). FA changes were statistically significant (P<0.037; Student's t-test). The Wilcoxon signed-ranks test showed significant reductions (P<0.005) in the human study. Motion-induced artifacts can be reduced by optimizing acquisition and reconstruction methods. The techniques described in this study offer an effective method for robust estimation of diffusion tensor in the presence of motion-related artifactual data points. (author)

  14. Fast tomosynthesis

    International Nuclear Information System (INIS)

    Klotz, E.; Linde, R.; Tiemens, U.; Weiss, H.

    1978-01-01

    A system has been constructed for fast tomosynthesis, whereby X-ray photographs are made of a single layer of an object. Twenty five X-ray tubes illuminate the object simultaneously at different angles. The resulting coded image is decoded by projecting it with a pattern of lenses that have the same form as the pattern of X-ray tubes. The coded image is optically correlated with the pattern of the sources. The scale of this can be adjusted so that the desired layer of the object is portrayed. Experimental results of its use in a hospital are presented. (C.F.)

  15. An efficient motion-resistant method for wearable pulse oximeter.

    Science.gov (United States)

    Yan, Yong-Sheng; Zhang, Yuan-Ting

    2008-05-01

    Reduction of motion artifact and power saving are crucial in designing a wearable pulse oximeter for long-term telemedicine application. In this paper, a novel algorithm, minimum correlation discrete saturation transform (MCDST) has been developed for the estimation of arterial oxygen saturation (SaO2), based on an optical model derived from photon diffusion analysis. The simulation shows that the new algorithm MCDST is more robust under low SNRs than the clinically verified motion-resistant algorithm discrete saturation transform (DST). Further, the experiment with different severity of motions demonstrates that MCDST has a slightly better performance than DST algorithm. Moreover, MCDST is more computationally efficient than DST because the former uses linear algebra instead of the time-consuming adaptive filter used by latter, which indicates that MCDST can reduce the required power consumption and circuit complexity of the implementation. This is vital for wearable devices, where the physical size and long battery life are crucial.

  16. Motion-insensitive rapid configuration relaxometry.

    Science.gov (United States)

    Nguyen, Damien; Bieri, Oliver

    2017-08-01

    Triple echo steady state (TESS) uses the lowest steady state configuration modes for rapid relaxometry. Due to its unbalanced gradient scheme, however, TESS is inherently motion-sensitive. The purpose of this work is to merge TESS with a balanced acquisition scheme for motion-insensitive rapid configuration relaxometry, termed MIRACLE. The lowest order steady state free precession (SSFP) configurations are retrieved by Fourier transformation of the frequency response of N frequency-shifted balanced SSFP (bSSFP) scans and subsequently processed for relaxometry, as proposed with TESS. Accuracy of MIRACLE is evaluated from simulations, phantom studies as well as in vivo brain and cartilage imaging at 3T. Simulations and phantom results revealed no conceptual flaw, and artifact-free configuration imaging was achieved in vivo. Overall, relaxometry results were accurate in phantoms and in good agreement for cartilage and for T2 in the brain, but apparent low T1 values were observed for brain white matter; reflecting asymmetries in the bSSFP profile. Rapid T1 and T2 mapping with MIRACLE offers analogous properties as TESS while successfully mitigating its motion-sensitivity. As a result of the Fourier transformation, relaxometry becomes sensitive to the voxel frequency distribution, which may contain useful physiologic information, such as structural brain integrity. © 2016 International Society for Magnetic Resonance in Medicine. Magn Reson Med 78:518-526, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Attention and apparent motion.

    Science.gov (United States)

    Horowitz, T; Treisman, A

    1994-01-01

    Two dissociations between short- and long-range motion in visual search are reported. Previous research has shown parallel processing for short-range motion and apparently serial processing for long-range motion. This finding has been replicated and it has also been found that search for short-range targets can be impaired both by using bicontrast stimuli, and by prior adaptation to the target direction of motion. Neither factor impaired search in long-range motion displays. Adaptation actually facilitated search with long-range displays, which is attributed to response-level effects. A feature-integration account of apparent motion is proposed. In this theory, short-range motion depends on specialized motion feature detectors operating in parallel across the display, but subject to selective adaptation, whereas attention is needed to link successive elements when they appear at greater separations, or across opposite contrasts.

  18. Reflection-artifact-free photoacoustic imaging using PAFUSion (photoacoustic-guided focused ultrasound)

    Science.gov (United States)

    Kuniyil Ajith Singh, Mithun; Jaeger, Michael; Frenz, Martin; Steenbergen, Wiendelt

    2016-03-01

    Reflection artifacts caused by acoustic inhomogeneities are a main challenge to deep-tissue photoacoustic imaging. Photoacoustic transients generated by the skin surface and superficial vasculature will propagate into the tissue and reflect back from echogenic structures to generate reflection artifacts. These artifacts can cause problems in image interpretation and limit imaging depth. In its basic version, PAFUSion mimics the inward travelling wave-field from blood vessel-like PA sources by applying focused ultrasound pulses, and thus provides a way to identify reflection artifacts. In this work, we demonstrate reflection artifact correction in addition to identification, towards obtaining an artifact-free photoacoustic image. In view of clinical applications, we implemented an improved version of PAFUSion in which photoacoustic data is backpropagated to imitate the inward travelling wave-field and thus the reflection artifacts of a more arbitrary distribution of PA sources that also includes the skin melanin layer. The backpropagation is performed in a synthetic way based on the pulse-echo acquisitions after transmission on each single element of the transducer array. We present a phantom experiment and initial in vivo measurements on human volunteers where we demonstrate significant reflection artifact reduction using our technique. The results provide a direct confirmation that reflection artifacts are prominent in clinical epi-photoacoustic imaging, and that PAFUSion can reduce these artifacts significantly to improve the deep-tissue photoacoustic imaging.

  19. Iterative image-domain ring artifact removal in cone-beam CT

    Science.gov (United States)

    Liang, Xiaokun; Zhang, Zhicheng; Niu, Tianye; Yu, Shaode; Wu, Shibin; Li, Zhicheng; Zhang, Huailing; Xie, Yaoqin

    2017-07-01

    Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain variations using flat-panel detectors, and may lead to structured non-uniformities and deterioration of image quality. The purpose of this study is to propose a method of general ring artifact removal in CBCT images. This method is based on the polar coordinate system, where the ring artifacts manifest as stripe artifacts. Using relative total variation, the CBCT images are first smoothed to generate template images with fewer image details and ring artifacts. By subtracting the template images from the CBCT images, residual images with image details and ring artifacts are generated. As the ring artifact manifests as a stripe artifact in a polar coordinate system, the artifact image can be extracted by mean value from the residual image; the image details are generated by subtracting the artifact image from the residual image. Finally, the image details are compensated to the template image to generate the corrected images. The proposed framework is iterated until the differences in the extracted ring artifacts are minimized. We use a 3D Shepp-Logan phantom, Catphan©504 phantom, uniform acrylic cylinder, and images from a head patient to evaluate the proposed method. In the experiments using simulated data, the spatial uniformity is increased by 1.68 times and the structural similarity index is increased from 87.12% to 95.50% using the proposed method. In the experiment using clinical data, our method shows high efficiency in ring artifact removal while preserving the image structure and detail. The iterative approach we propose for ring artifact removal in cone-beam CT is practical and attractive for CBCT guided radiation therapy.

  20. Objects in Motion

    Science.gov (United States)

    Damonte, Kathleen

    2004-01-01

    One thing scientists study is how objects move. A famous scientist named Sir Isaac Newton (1642-1727) spent a lot of time observing objects in motion and came up with three laws that describe how things move. This explanation only deals with the first of his three laws of motion. Newton's First Law of Motion says that moving objects will continue…

  1. Demand artifact: objectively detecting biased participants in advertising research.

    Science.gov (United States)

    Miller, Felicia; Schertzer, Susan

    2014-12-01

    Detecting and reducing the effect of biased participants continues to be an important task for researchers. However, the lack of objective measures to assess demand artifact has made it difficult to effectively address this issue. This paper reports two experiments that apply a theory-based post-experimental inquiry that can systematically identify biased participants in consumer research. The results demonstrate how easily and effectively researchers can incorporate this tool into experimental studies of all types and reduce the likelihood of systematic error.

  2. The measurement artifact in the Organizational Commitment Questionnaire.

    Science.gov (United States)

    Caught, K; Shadur, M A; Rodwell, J J

    2000-12-01

    This study empirically examined the debate in the literature regarding the dimensionality of the Organizational Commitment Questionnaire. The sample comprised 803 employees from organizations in the information technology and hospitality industries. Confirmatory factor analysis showed that the Organizational Commitment Questionnaire appears to have a two-factor structure, with one factor consisting of positively worded items and the other factor, negatively worded items. Scores on both factors correlated significantly with job satisfaction, suggesting that both factors appear to be measuring a similar aspect of organizational commitment and that they present as two factors given as measurement artifacts of the item wording.

  3. Development of an artifact-free aneurysm clip

    Directory of Open Access Journals (Sweden)

    Brack Alexander

    2016-09-01

    Full Text Available For the treatment of intracranial aneurysms with aneurysm clips, usually a follow-up inspection in MRI is required. To avoid any artifacts, which can make a proper diagnosis difficult, a new approach for the manufacturing of an aneurysm clip entirely made from fiber-reinforced plastics has been developed. In this paper the concept for the design of the clip, the development of a new manufacturing technology for the fiber-reinforced components as well as first results from the examination of the components in phantom MRI testing is shown.

  4. Gold-wire artifacts on diagnostic radiographs: A case report

    International Nuclear Information System (INIS)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc

    2014-01-01

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  5. Gold-wire artifacts on diagnostic radiographs: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc [Dept. of Oral Health Sciences, KU Leuven and Dentistry, University Hospitals, KU Leuven, Leuven (Belgium)

    2014-03-15

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  6. TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Li, G; Zakian, K; Deasy, J [Memorial Sloan Kettering Cancer Center, New York, NY (United States); Wei, J [City College of New York, New York, NY (United States); Hunt, M [Mem Sloan-Kettering Cancer Ctr, New York, NY (United States)

    2016-06-15

    Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI

  7. Contributions of an adiabatic initial inversion pulse and K-space Re-ordered by inversion-time at each slice position (KRISP) to control of CSF artifacts and visualization of the brain in FLAIR magnetic resonance imaging

    International Nuclear Information System (INIS)

    Curati, Walter L.; Oatridge, Angela; Herlihy, Amy H.; Hajnal, Joseph V.; Puri, Basant K.; Bydder, Graeme M.

    2001-01-01

    AIM: The aim of this study was to compare the performance of three fluid attenuated inversion recovery (FLAIR) pulse sequences for control of cerebrospinal fluid (CSF) and blood flow artifacts in imaging of the brain. The first of these sequences had an initial sinc inversion pulse which was followed by conventional k-space mapping. The second had an initial sinc inversion pulse followed by k-space re-ordered by inversion time at each slice position (KRISP) and the third had an adiabatic initial inversion pulse followed by KRISP. MATERIALS AND METHODS: Ten patients with established disease were studied with all three pulse sequences. Seven were also studied with the adiabatic KRISP sequence after contrast enhancement. Their images were evaluated for patient motion artifact, CSF and blood flow artifact as well as conspicuity of the cortex, meninges, ventricular system, brainstem and cerebellum. The conspicuity of lesions and the degree of enhancement were also evaluated. RESULTS: Both the sinc and adiabatic KRISP FLAIR sequences showed better control of CSF and blood flow artifacts than the conventional FLAIR sequence. In addition the adiabatic KRISP FLAIR sequence showed better control of CSF artifact at the inferior aspect of the posterior fossa. The lesion conspicuity was similar for each of the FLAIR sequences as was the degree of contrast enhancement to that shown with a T 1 weighted spin echo sequence. CONCLUSION: The KRISP FLAIR sequence controls high signal artifacts from CSF flow and blood flow and the adiabatic pulse controls high signal artifacts due to inadequate inversion of the CSF magnetization at the periphery of the head transmitter coil. The KRISP FLAIR sequence also improves cortical and meningeal definition as a result of an edge enhancement effect. The effects are synergistic and can be usefully combined in a single pulse sequence. Curati, W.L. et al. (2001)

  8. Automatic minimization of ocular artifacts fromelectroencephalogram: A novel approach by combining CompleteEEMD with Adaptive Noise and Renyi’s Entropy

    DEFF Research Database (Denmark)

    Guarascio, Mario; Puthusserypady, Sadasivan

    2017-01-01

    forminimizing the OAs from corrupted EEG signals. The RE criterion is suggested to automatically select theIntrinsic Mode Functions (IMFs) to reconstruct the artifact minimized EEG signals. The scheme requiresonly a single channel OAs corrupted EEG recording and a reasonable computation time. The methodis first......Ocular artifacts (OAs) are one of the major interferences that obscure electroencephalogram (EEG) signals.In this paper, a novel, completely automatic, adaptive and fast method that combines the CompleteEmpirical Mode Decomposition with Adaptive Noise (CEEMDAN) and Renyi’s Entropy (RE) is proposed....... The method is compared to the one based on the CEEMDAN and manual choice of IMFsfor OAs minimization from EEG. Results from extensive simulation studies clearly indicate the efficacyof the proposed scheme in automatically minimizing the OAs from the corrupted EEG signals....

  9. Indexing Motion Detection Data for Surveillance Video

    DEFF Research Database (Denmark)

    Vind, Søren Juhl; Bille, Philip; Gørtz, Inge Li

    2014-01-01

    We show how to compactly index video data to support fast motion detection queries. A query specifies a time interval T, a area A in the video and two thresholds v and p. The answer to a query is a list of timestamps in T where ≥ p% of A has changed by ≥ v values. Our results show that by building...... a small index, we can support queries with a speedup of two to three orders of magnitude compared to motion detection without an index. For high resolution video, the index size is about 20% of the compressed video size....

  10. Closed-Loop Control of Humidification for Artifact Reduction in Capacitive ECG Measurements.

    Science.gov (United States)

    Leicht, Lennart; Eilebrecht, Benjamin; Weyer, Soren; Leonhardt, Steffen; Teichmann, Daniel

    2017-04-01

    Recording biosignals without the need for direct skin contact offers new opportunities for ubiquitous health monitoring. Electrodes with capacitive coupling have been shown to be suitable for the monitoring of electrical potentials on the body surface, in particular ECG. However, due to triboelectric charge generation and motion artifacts, signal and thus diagnostic quality is inferior to galvanic coupling. Active closed-loop humidification of capacitive electrodes is proposed in this work as a new concept to improve signal quality. A capacitive ECG recording system integrated into a common car seat is presented. It can regulate the micro climate at the interface of electrode and patient by actively dispensing water vapour and monitoring humidity in a closed-loop approach. As a regenerative water reservoir, silica gel is used. The system was evaluated with respect to subjective and objective ECG signal quality. Active humidification was found to have a significant positive effect in case of previously poor quality. Also, it had no diminishing effect in case of already good signal quality.

  11. Smoothing Motion Estimates for Radar Motion Compensation.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Simple motion models for complex motion environments are often not adequate for keeping radar data coherent. Eve n perfect motion samples appli ed to imperfect models may lead to interim calculations e xhibiting errors that lead to degraded processing results. Herein we discuss a specific i ssue involving calculating motion for groups of pulses, with measurements only available at pulse-group boundaries. - 4 - Acknowledgements This report was funded by General A tomics Aeronautical Systems, Inc. (GA-ASI) Mission Systems under Cooperative Re search and Development Agre ement (CRADA) SC08/01749 between Sandia National Laboratories and GA-ASI. General Atomics Aeronautical Systems, Inc. (GA-ASI), an affilia te of privately-held General Atomics, is a leading manufacturer of Remotely Piloted Aircraft (RPA) systems, radars, and electro-optic and rel ated mission systems, includin g the Predator(r)/Gray Eagle(r)-series and Lynx(r) Multi-mode Radar.

  12. Apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

    Directory of Open Access Journals (Sweden)

    Ioannis Pneumatikos

    2008-10-01

    Full Text Available Respiratory motion artifact in intubated and mechanically ventilated patients often reduces the quality of helical computed tomography pulmonary angiography (CTPA. Apneic oxygenation is a well established intra-operative technique that allows adequate oxygenation for short periods (up to 10 min in sedated and paralyzed patients. We describe the use of the apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

  13. A Motion-Adaptive Deinterlacer via Hybrid Motion Detection and Edge-Pattern Recognition

    Directory of Open Access Journals (Sweden)

    He-Yuan Lin

    2008-03-01

    Full Text Available A novel motion-adaptive deinterlacing algorithm with edge-pattern recognition and hybrid motion detection is introduced. The great variety of video contents makes the processing of assorted motion, edges, textures, and the combination of them very difficult with a single algorithm. The edge-pattern recognition algorithm introduced in this paper exhibits the flexibility in processing both textures and edges which need to be separately accomplished by line average and edge-based line average before. Moreover, predicting the neighboring pixels for pattern analysis and interpolation further enhances the adaptability of the edge-pattern recognition unit when motion detection is incorporated. Our hybrid motion detection features accurate detection of fast and slow motion in interlaced video and also the motion with edges. Using only three fields for detection also renders higher temporal correlation for interpolation. The better performance of our deinterlacing algorithm with higher content-adaptability and less memory cost than the state-of-the-art 4-field motion detection algorithms can be seen from the subjective and objective experimental results of the CIF and PAL video sequences.

  14. A Motion-Adaptive Deinterlacer via Hybrid Motion Detection and Edge-Pattern Recognition

    Directory of Open Access Journals (Sweden)

    Li Hsin-Te

    2008-01-01

    Full Text Available Abstract A novel motion-adaptive deinterlacing algorithm with edge-pattern recognition and hybrid motion detection is introduced. The great variety of video contents makes the processing of assorted motion, edges, textures, and the combination of them very difficult with a single algorithm. The edge-pattern recognition algorithm introduced in this paper exhibits the flexibility in processing both textures and edges which need to be separately accomplished by line average and edge-based line average before. Moreover, predicting the neighboring pixels for pattern analysis and interpolation further enhances the adaptability of the edge-pattern recognition unit when motion detection is incorporated. Our hybrid motion detection features accurate detection of fast and slow motion in interlaced video and also the motion with edges. Using only three fields for detection also renders higher temporal correlation for interpolation. The better performance of our deinterlacing algorithm with higher content-adaptability and less memory cost than the state-of-the-art 4-field motion detection algorithms can be seen from the subjective and objective experimental results of the CIF and PAL video sequences.

  15. Curves from Motion, Motion from Curves

    Science.gov (United States)

    2000-01-01

    De linearum curvarum cum lineis rectis comparatione dissertatio geometrica - an appendix to a treatise by de Lalouv~re (this was the only publication... correct solution to the problem of motion in the gravity of a permeable rotating Earth, considered by Torricelli (see §3). If the Earth is a homogeneous...in 1686, which contains the correct solution as part of a remarkably comprehensive theory of orbital motions under centripetal forces. It is a

  16. Kernel principal component analysis residual diagnosis (KPCARD): An automated method for cosmic ray artifact removal in Raman spectra

    International Nuclear Information System (INIS)

    Li, Boyan; Calvet, Amandine; Casamayou-Boucau, Yannick; Ryder, Alan G.

    2016-01-01

    A new, fully automated, rapid method, referred to as kernel principal component analysis residual diagnosis (KPCARD), is proposed for removing cosmic ray artifacts (CRAs) in Raman spectra, and in particular for large Raman imaging datasets. KPCARD identifies CRAs via a statistical analysis of the residuals obtained at each wavenumber in the spectra. The method utilizes the stochastic nature of CRAs; therefore, the most significant components in principal component analysis (PCA) of large numbers of Raman spectra should not contain any CRAs. The process worked by first implementing kernel PCA (kPCA) on all the Raman mapping data and second accurately estimating the inter- and intra-spectrum noise to generate two threshold values. CRA identification was then achieved by using the threshold values to evaluate the residuals for each spectrum and assess if a CRA was present. CRA correction was achieved by spectral replacement where, the nearest neighbor (NN) spectrum, most spectroscopically similar to the CRA contaminated spectrum and principal components (PCs) obtained by kPCA were both used to generate a robust, best curve fit to the CRA contaminated spectrum. This best fit spectrum then replaced the CRA contaminated spectrum in the dataset. KPCARD efficacy was demonstrated by using simulated data and real Raman spectra collected from solid-state materials. The results showed that KPCARD was fast ( 1 million) Raman datasets. - Highlights: • New rapid, automatable method for cosmic ray artifact correction of Raman spectra. • Uses combination of kernel PCA and noise estimation for artifact identification. • Implements a best fit spectrum replacement correction approach.

  17. PET Motion Compensation for Radiation Therapy Using a CT-Based Mid-Position Motion Model: Methodology and Clinical Evaluation

    International Nuclear Information System (INIS)

    Kruis, Matthijs F.; Kamer, Jeroen B. van de; Houweling, Antonetta C.; Sonke, Jan-Jakob; Belderbos, José S.A.; Herk, Marcel van

    2013-01-01

    Purpose: Four-dimensional positron emission tomography (4D PET) imaging of the thorax produces sharper images with reduced motion artifacts. Current radiation therapy planning systems, however, do not facilitate 4D plan optimization. When images are acquired in a 2-minute time slot, the signal-to-noise ratio of each 4D frame is low, compromising image quality. The purpose of this study was to implement and evaluate the construction of mid-position 3D PET scans, with motion compensated using a 4D computed tomography (CT)-derived motion model. Methods and Materials: All voxels of 4D PET were registered to the time-averaged position by using a motion model derived from the 4D CT frames. After the registration the scans were summed, resulting in a motion-compensated 3D mid-position PET scan. The method was tested with a phantom dataset as well as data from 27 lung cancer patients. Results: PET motion compensation using a CT-based motion model improved image quality of both phantoms and patients in terms of increased maximum SUV (SUV max ) values and decreased apparent volumes. In homogenous phantom data, a strong relationship was found between the amplitude-to-diameter ratio and the effects of the method. In heterogeneous patient data, the effect correlated better with the motion amplitude. In case of large amplitudes, motion compensation may increase SUV max up to 25% and reduce the diameter of the 50% SUV max volume by 10%. Conclusions: 4D CT-based motion-compensated mid-position PET scans provide improved quantitative data in terms of uptake values and volumes at the time-averaged position, thereby facilitating more accurate radiation therapy treatment planning of pulmonary lesions

  18. Structural motion engineering

    CERN Document Server

    Connor, Jerome

    2014-01-01

    This innovative volume provides a systematic treatment of the basic concepts and computational procedures for structural motion design and engineering for civil installations. The authors illustrate the application of motion control to a wide spectrum of buildings through many examples. Topics covered include optimal stiffness distributions for building-type structures, the role of damping in controlling motion, tuned mass dampers, base isolation systems, linear control, and nonlinear control. The book's primary objective is the satisfaction of motion-related design requirements, such as restrictions on displacement and acceleration. The book is ideal for practicing engineers and graduate students. This book also: ·         Broadens practitioners' understanding of structural motion control, the enabling technology for motion-based design ·         Provides readers the tools to satisfy requirements of modern, ultra-high strength materials that lack corresponding stiffness, where the motion re...

  19. Terahertz Absorption by Cellulose: Application to Ancient Paper Artifacts

    Science.gov (United States)

    Peccianti, M.; Fastampa, R.; Mosca Conte, A.; Pulci, O.; Violante, C.; Łojewska, J.; Clerici, M.; Morandotti, R.; Missori, M.

    2017-06-01

    Artifacts made of cellulose, such as ancient documents, pose a significant experimental challenge in the terahertz transmission spectra interpretation due to their small optical thickness. In this paper, we describe a method to recover the complex refractive index of cellulose fibers from the terahertz transmission data obtained on single freely standing paper sheets in the (0.2-3.5)-THz range. By using our technique, we eliminate Fabry-Perot effects and recover the absorption coefficient of the cellulose fibers. The obtained terahertz absorption spectra are explained in terms of absorption peaks of the cellulose crystalline phase superimposed to a background contribution due to a disordered hydrogen-bond network. The comparison between the experimental spectra with terahertz vibrational properties simulated by density-functional-theory calculations confirms this interpretation. In addition, evident changes in the terahertz absorption spectra are produced by natural and artificial aging on paper samples, whose final stage is characterized by a spectral profile with only two peaks at about 2.1 and 3.1 THz. These results can be used to provide a quantitative assessment of the state of preservation of cellulose artifacts.

  20. Packaging Design. A Systemic Approach to a Complex Artifact

    Directory of Open Access Journals (Sweden)

    Erik Ciravegna

    2017-12-01

    Full Text Available Packaging is a complex artifact, which has considerably expanded its functions over time. It is an object of use (instrumental prosthesis, which allows to contain the product, protect it, store it, transport it, and at the same time, facilitate its physical interaction with the user. Also, it is communication device (communication prosthesis, characterized by functions, among others, of appellative, persuasive, informative and prescriptive kind. For its multifaceted nature, the project of a package requires different skills and the intervention of multiple disciplines: for that reason, should be understood as the result of an integrated set of choices made by a plurality of actors, where each performs a specific role – direct or indirect – in its definition. These actors, together with the relationships that are established throughout the product life cycle, define the so-called “packaging-system”. Within this system, Design –and specifically Communication Design– may play an important role in direction and mediation, potentially giving shape through the project synthesis to solutions which are an expression of the confluence of the needs of the different parties involved and the multiple functions of the artifact, connecting the communicative dimension to a strictly instrumental dimension.

  1. Signs of η Carinae Outburst in Artifacts of Ancient Bolivia

    Science.gov (United States)

    Teames, Sallie

    Recent HST and X-ray photos of η Carinae reveal the bipolar gaseous lobes--the Homunculus Nebula--created by the star's "Great Eruption of 1843." From debris gases on the outskirts beyond the two gaseous lobes, astrophysicists surmise an earlier outburst. The 1999 Chandra X-ray photo of the horseshoe-shaped outer nebula surrounding the bipolar lobes indicates an earlier outburst occurring over a thousand years ago. Because η Carinae is so far south, it is entirely possible that the outburst would not have been seen by the Chinese and other observers in the northern hemisphere. Researchers are looking for possible recordings by early southern hemisphere observers. Pre-Incan artifacts excavated in Bolivia may provide an answer. In the script and artwork carvings on a monolith stone statue, an artifact of the Tiahuanacan culture, are signs possibly depicting the earlier outburst of η Carinae--the recordings of a star that suddenly brightened in their night sky. Two small stones from the same era and also found on the south shore of Lake Titicaca may also show depictions related to this brightening.

  2. A convolutional neural network to filter artifacts in spectroscopic MRI.

    Science.gov (United States)

    Gurbani, Saumya S; Schreibmann, Eduard; Maudsley, Andrew A; Cordova, James Scott; Soher, Brian J; Poptani, Harish; Verma, Gaurav; Barker, Peter B; Shim, Hyunsuk; Cooper, Lee A D

    2018-03-09

    Proton MRSI is a noninvasive modality capable of generating volumetric maps of in vivo tissue metabolism without the need for ionizing radiation or injected contrast agent. Magnetic resonance spectroscopic imaging has been shown to be a viable imaging modality for studying several neuropathologies. However, a key hurdle in the routine clinical adoption of MRSI is the presence of spectral artifacts that can arise from a number of sources, possibly leading to false information. A deep learning model was developed that was capable of identifying and filtering out poor quality spectra. The core of the model used a tiled convolutional neural network that analyzed frequency-domain spectra to detect artifacts. When compared with a panel of MRS experts, our convolutional neural network achieved high sensitivity and specificity with an area under the curve of 0.95. A visualization scheme was implemented to better understand how the convolutional neural network made its judgement on single-voxel or multivoxel MRSI, and the convolutional neural network was embedded into a pipeline capable of producing whole-brain spectroscopic MRI volumes in real time. The fully automated method for assessment of spectral quality provides a valuable tool to support clinical MRSI or spectroscopic MRI studies for use in fields such as adaptive radiation therapy planning. © 2018 International Society for Magnetic Resonance in Medicine.

  3. Racial IQ Differences among Transracial Adoptees: Fact or Artifact?

    Directory of Open Access Journals (Sweden)

    Drew Thomas

    2016-12-01

    Full Text Available Some academic publications infer from studies of transracial adoptees’ IQs that East Asian adoptees raised in the West by Whites have higher IQs than Western Whites, and that White adoptees raised by Whites have higher IQs than Black adoptees raised by Whites. Those publications suggest that this is because genetic differences give East Asians a higher mean IQ than Whites, and Whites a higher mean IQ than Blacks. This paper proposes a parsimonious alternative explanation: the apparent IQ advantage of East Asian adoptees is an artifact caused by ignoring the Flynn effect and adoption’s beneficial effect on IQ, and most of the IQ disadvantage of Black adoptees disappears when one allows for attrition in the Minnesota Transracial Adoption Study, and acknowledges the results of other studies. Diagnosing these artifacts suggests a nil hypothesis: East Asian, White, and Black adoptees raised in the same environment would have similar IQs, hinting at a minimal role for genes in racial IQ differences.

  4. Optical nano artifact metrics using silicon random nanostructures

    Science.gov (United States)

    Matsumoto, Tsutomu; Yoshida, Naoki; Nishio, Shumpei; Hoga, Morihisa; Ohyagi, Yasuyuki; Tate, Naoya; Naruse, Makoto

    2016-08-01

    Nano-artifact metrics exploit unique physical attributes of nanostructured matter for authentication and clone resistance, which is vitally important in the age of Internet-of-Things where securing identities is critical. However, expensive and huge experimental apparatuses, such as scanning electron microscopy, have been required in the former studies. Herein, we demonstrate an optical approach to characterise the nanoscale-precision signatures of silicon random structures towards realising low-cost and high-value information security technology. Unique and versatile silicon nanostructures are generated via resist collapse phenomena, which contains dimensions that are well below the diffraction limit of light. We exploit the nanoscale precision ability of confocal laser microscopy in the height dimension; our experimental results demonstrate that the vertical precision of measurement is essential in satisfying the performances required for artifact metrics. Furthermore, by using state-of-the-art nanostructuring technology, we experimentally fabricate clones from the genuine devices. We demonstrate that the statistical properties of the genuine and clone devices are successfully exploited, showing that the liveness-detection-type approach, which is widely deployed in biometrics, is valid in artificially-constructed solid-state nanostructures. These findings pave the way for reasonable and yet sufficiently secure novel principles for information security based on silicon random nanostructures and optical technologies.

  5. Social web artifacts for boosting recommenders theory and implementation

    CERN Document Server

    Ziegler, Cai-Nicolas

    2013-01-01

    Recommender systems, software programs that learn from human behavior and make predictions of what products we are expected to appreciate and purchase, have become an integral part of our everyday life. They proliferate across electronic commerce around the globe and exist for virtually all sorts of consumable goods, such as books, movies, music, or clothes. At the same time, a new evolution on the Web has started to take shape, commonly known as the “Web 2.0” or the “Social Web”: Consumer-generated media has become rife, social networks have emerged and are pulling significant shares of Web traffic. In line with these developments, novel information and knowledge artifacts have become readily available on the We