WorldWideScience

Sample records for faraday fast track

  1. Fast Faraday Cup With High Bandwidth

    Science.gov (United States)

    Deibele, Craig E [Knoxville, TN

    2006-03-14

    A circuit card stripline Fast Faraday cup quantitatively measures the picosecond time structure of a charged particle beam. The stripline configuration maintains signal integrity, and stitching of the stripline increases the bandwidth. A calibration procedure ensures the measurement of the absolute charge and time structure of the charged particle beam.

  2. Faraday-cup-type lost fast ion detector on Heliotron J

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, S., E-mail: yamamoto.satoshi.6n@kyoto-u.ac.jp; Kobayashi, S.; Nagasaki, K.; Okada, H.; Minami, T.; Kado, S.; Ohshima, S.; Weir, G. M.; Konoshima, S.; Mizuuchi, T. [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Ogawa, K.; Isobe, M. [National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Darrow, D. S. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Nakamura, Y.; Ohtani, Y. [Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Kemmochi, N. [National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan)

    2016-11-15

    A Faraday-cup type lost-fast ion probe (FLIP) has been designed and installed in Heliotron J for the purpose of the studies of interaction between fast ions and MHD instabilities. The FLIP can measure the co-going fast ions whose energy is in the range of 1.7–42.5 keV (proton) and pitch angle of 90{sup ∘}–140{sup ∘}, especially for fast ions having the injection energy of neutral beam injection (NBI). The FLIP successfully measured the re-entering passing ions and trapped lost-fast ions caused by fast-ion-driven energetic particle modes in NBI heated plasmas.

  3. New conceptual antenna with spiral structure and back Faraday shield for FWCD (fast wave current drive)

    International Nuclear Information System (INIS)

    Saigusa, M.; Moriyama, S.; Fujii, T.; Kimura, H.

    1994-01-01

    A new conceptual antenna, which we call as a spiral antenna, is proposed as a traveling wave antenna for fast wave current drive in tokamaks. The features of the spiral antenna are a sharp N z spectrum, easy impedance matching, N z controllable and good coupling. A back Faraday shield is proposed for improving the cooling design of Faraday shield and better antenna-plasma coupling. A helical support which is a compact and wide band support is proposed as a kind of quarter wave length stub supports. The RF properties of the spiral antenna and the back Faraday shield have been investigated by using mock-up antennas. The VSWR of spiral antenna is low at the wide frequency band from 15 MHz to 201 MHz. The back Faraday shield is effective for suppressing the RF toroidal electric field between adjacent currents straps. (author)

  4. Fast track-hoftealloplastik

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Gromov, Kirill; Kristensen, Billy B

    2017-01-01

    Fast-track surgery implies a coordinated perioperative approach aimed at reducing surgical stress and facilitating post-operative recovery. The fast-track programme has reduced post-operative length of stay and has led to shorter convalescence with more rapid functional recovery and decreased...... morbidity and mortality in total hip arthroplasty. It should now be a standard total hip arthroplasty patient pathway, but fine tuning of the multiple factors in the fast-track pathway is still needed in patients with special needs or high comorbidity burden....

  5. Design of high current bunching system and high power fast Faraday cup for high current LEBT at VECC

    International Nuclear Information System (INIS)

    Anuraag Misra, A.; Pandit, B.V.S.; Gautam Pal, C.

    2011-01-01

    A high current microwave ion source as described is currently operational at VECC. We are able to optimize 6.4 mA of proton current in the LEBT line of ion source. The cyclotron type of accelerators accept only a fraction of DC ion beam coming from ion source so a ion beam buncher is needed to increase the accepted current into the cyclotron. The buncher described in this paper is unique in its kind as it has to handle high beam loading power upto 400 W as it is designed to bunch few mA of proton beam currents at 80 keV beam energy. A sinusoidal quarter wave RF structure has been chosen to bunch the high current beam due to high Q achievable in comparison with other configurations. This buncher has been designed using CST Microwave studio 3D advanced code since the design frequency of our buncher is 42 MHz, we have provided the RF and vacuum window near the drift tube of buncher to avoid vacuum and multipacting problems and to keep maximum volume in air region. There is a provision of multipacting interlocks to shut off amplifier during multipacting. We have carried out a detailed electromagnetic and thermal design of the buncher in CST Microwave studio and simulated values of unloaded Q was calculated be 4000. We have estimated a power of 400 W to achieve gap (designed) voltage of 10 kV. This buncher is in advanced stage of fabrication. A high power fast Faraday cup is also designed to characterize the above mentioned high current bunching system. The fast Faraday cup is designed in 50 Ω coaxial geometry to transmit fast pulse of bunched ion beam. The design of Faraday cup was completed using ANSYS HFSS and a bandwidth of 1.75 GHz was achieved this faraday cup design was different from conventional Faraday cup design as we have designed the support and cooling lines at such a place on Faraday cup which do not disturb the electrical impedance of the cup. (author)

  6. Faraday rotation measurement method and apparatus

    Science.gov (United States)

    Brockman, M. H. (Inventor)

    1981-01-01

    A method and device for measuring Faraday rotation of a received RF signal is described. A simultaneous orthogonal polarization receiver compensates for a 3 db loss due to splitting of a received signal into left circular and right circular polarization channels. The compensation is achieved by RF and modulation arraying utilizing a specific receiver array which also detects and measures Faraday rotation in the presence or absence of spin stabilization effects on a linear polarization vector. Either up-link or down-link measurement of Faraday rotation is possible. Specifically, the Faraday measurement apparatus utilized in conjunction with the specific receiver array provides a means for comparing the phase of a reference signal in the receiver array to the phase of a tracking loop signal related to the incoming signal, and comparing the phase of the reference signal to the phase of the tracking signal shifted in phase by 90 degrees. The averaged and unaveraged signals, are compared, the phase changes between the two signals being related to Faraday rotation.

  7. Fast-track totalknæalloplastik

    DEFF Research Database (Denmark)

    Gromov, Kirill; Kristensen, Billy B; Jørgensen, Christoffer Calov

    2017-01-01

    patients are eligible for fast-track TKA, and hence the fast-track concept should be standard at all joint replacement facilities. Future challenges of fast-track TKA include safe introduction of outpatient protocols, acute and chronic pain after surgery and optimal utilization of post......Fast-track total knee arthroplasty (TKA) is a well-established concept including optimized logistics and evidence-based treatment, focusing on minimizing surgical stress and improved post-operative recovery, thus leading to lower mortality and morbidity as well as high patient satisfaction. All...

  8. Parasitic excitation of ion Bernstein waves from a Faraday shielded fast wave loop antenna

    International Nuclear Information System (INIS)

    Skiff, F.; Ono, M.; Colestock, P.; Wong, K.L.

    1984-12-01

    Parasitic excitation of ion Bernstein waves is observed from a Faraday shielded fast wave loop antenna in the ion cyclotron frequency range. Local analysis of the Vlasov-Maxwell equations demonstrates the role of plasma density gradient in the coupling process. The effects of plasma density and of parallel wave number on the excitation process are investigated

  9. Design of a tapered stripline fast Faraday cup for measurements on heavy ion beams: problems and solutions

    International Nuclear Information System (INIS)

    Marcellini, F.; Poggi, M.

    1998-01-01

    The design of a tapered stripline fast Faraday cup (TSFFC) to perform the impedance matching between the fast cup itself and the signal line (connector, cable, and amplifier) is reported here. The frequency response of the TSFFC as a high-pass filter is analyzed from a theoretical point of view and some solutions to achieve a broadband response are given

  10. Percentage of Fast-Track Receipts

    Data.gov (United States)

    Social Security Administration — The dataset provides the percentage of fast-track receipts by state during the reporting fiscal year. Fast-tracked cases consist of those cases identified as Quick...

  11. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... on clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects...... of the hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  12. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery....... Methods 29 patients were operated with 30 revision arthroplasties. Median age was 67 (34-84) years. All patients followed a standardized fast-track set-up designed for primary TKA. We determined the outcome regarding LOS, morbidity, mortality, and satisfaction. Results Median LOS was 2 (1-4) days...

  13. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery...

  14. Fast Faraday fading of long range satellite signals.

    Science.gov (United States)

    Heron, M. L.

    1972-01-01

    20 MHz radio signals have been received during the day from satellite Beacon-B when it was below the optical horizon by using a bank of narrow filters to improve the signal to noise ratio. The Faraday fading rate becomes constant, under these conditions, at a level determined by the plasma frequency just below the F-layer peak. Variations in the Faraday fading rate reveal fluctuations in the electron density near the peak, while the rate of attaining the constant level depends on the shape of the electron density profile.

  15. Cardiac surgery fast-track treatment in a postanesthetic care unit: six-month results of the Leipzig fast-track concept.

    Science.gov (United States)

    Ender, Joerg; Borger, Michael Andrew; Scholz, Markus; Funkat, Anne-Kathrin; Anwar, Nadeem; Sommer, Marcus; Mohr, Friedrich Wilhelm; Fassl, Jens

    2008-07-01

    The authors compared the safety and efficacy of a newly developed fast-track concept at their center, including implementation of a direct admission postanesthetic care unit, to standard perioperative management. All fast-track patients treated within the first 6 months of implementation of our direct admission postanesthetic care unit were matched via propensity scores and compared with a historical control group of patients who underwent cardiac surgery prior to fast-track implementation. A total of 421 fast-track patients were matched successfully to 421 control patients. The two groups of patients had a similar age (64 +/- 13 vs. 64 +/- 12 yr for fast-track vs. control, P = 0.45) and European System for Cardiac Operative Risk Evaluation-predicted risk of mortality (4.8 +/- 6.1% vs. 4.6 +/- 5.1%, P = 0.97). Fast-track patients had significantly shorter times to extubation (75 min [45-110] vs. 900 min [600-1140]), as well as shorter lengths of stay in the postanesthetic or intensive care unit (4 h [3.0-5] vs. 20 h [16-25]), intermediate care unit (21 h [17-39] vs. 26 h [19-49]), and hospital (10 days [8-12] vs. 11 days [9-14]) (expressed as median and interquartile range, all P operations.

  16. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

    International Nuclear Information System (INIS)

    Hu Jing; Rovey, Joshua L.

    2011-01-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

  17. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization.

    Science.gov (United States)

    Hu, Jing; Rovey, Joshua L

    2011-07-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a "double-humped" energy distribution.

  18. Detection of nitro-based and peroxide-based explosives by fast polarity-switchable ion mobility spectrometer with ion focusing in vicinity of Faraday detector.

    Science.gov (United States)

    Zhou, Qinghua; Peng, Liying; Jiang, Dandan; Wang, Xin; Wang, Haiyan; Li, Haiyang

    2015-05-29

    Ion mobility spectrometer (IMS) has been widely deployed for on-site detection of explosives. The common nitro-based explosives are usually detected by negative IMS while the emerging peroxide-based explosives are better detected by positive IMS. In this study, a fast polarity-switchable IMS was constructed to detect these two explosive species in a single measurement. As the large traditional Faraday detector would cause a trailing reactant ion peak (RIP), a Faraday detector with ion focusing in vicinity was developed by reducing the detector radius to 3.3 mm and increasing the voltage difference between aperture grid and its front guard ring to 591 V, which could remove trailing peaks from RIP without loss of signal intensity. This fast polarity-switchable IMS with ion focusing in vicinity of Faraday detector was employed to detect a mixture of 10 ng 2,4,6-trinitrotoluene (TNT) and 50 ng hexamethylene triperoxide diamine (HMTD) by polarity-switching, and the result suggested that [TNT-H](-) and [HMTD+H](+) could be detected in a single measurement. Furthermore, the removal of trailing peaks from RIP by the Faraday detector with ion focusing in vicinity also promised the accurate identification of KClO4, KNO3 and S in common inorganic explosives, whose product ion peaks were fairly adjacent to RIP.

  19. ATLAS FTK: Fast Track Trigger

    CERN Document Server

    Volpi, Guido; The ATLAS collaboration

    2015-01-01

    An overview of the ATLAS Fast Tracker processor is presented, reporting the design of the system, its expected performance, and the integration status. The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge to the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency in interesting events, despite the increase in multiple p-p collisions per bunch crossing (pile-up). In order to increase the use of tracks within the High Level Trigger (HLT), the ATLAS experiment planned the installation of an hardware processor dedicated to tracking: the Fast TracKer (FTK) processor. The FTK is designed to perform full scan track reconstruction at every Level-1 accept. To achieve this goal, the FTK uses a fully parallel architecture, with algorithms designed to exploit the computing power of custom VLSI chips, the Associative Memory, as well as modern FPGAs. The FT...

  20. Fast-track video-assisted thoracoscopic surgery

    DEFF Research Database (Denmark)

    Holbek, Bo Laksafoss; Petersen, René Horsleben; Kehlet, Henrik

    2016-01-01

    Objectives To provide a short overview of fast-track video-assisted thoracoscopic surgery (VATS) and to identify areas requiring further research. Design A literature search was made using key words including: fast-track, enhanced recovery, video-assisted thoracoscopic surgery, robot......-assisted thoracoscopic surgery (RATS), robotic, thoracotomy, single-incision, uniportal, natural orifice transluminal endoscopic surgery (NOTES), chest tube, air-leak, digital drainage, pain management, analgesia, perioperative management, anaesthesia and non-intubated. References from articles were screened for further...

  1. [Fast-track treatment--second revolution of colorectal surgery].

    Science.gov (United States)

    Kellokumpu, Ilmo

    2012-01-01

    The fast-track treatment model can be regarded as the second revolution of colorectal surgery after the introduction of laparoscopic surgery. In the gastro-surgical unit of the Central Hospital of Central Finland, results equivalent to international studies in colorectal surgery have been achieved by using fast-track model. In a study setting, this treatment model has resulted in significant decrease of total treatment costs and speeded up discharge of the patients from the hospital. The fast-track treatment model requires both a motivated, trained medical team and a motivated patient.

  2. Use of Faraday-rotation data from beacon satellites to determine ionospheric corrections for interplanetary spacecraft navigation

    Science.gov (United States)

    Royden, H. N.; Green, D. W.; Walson, G. R.

    1981-01-01

    Faraday-rotation data from the linearly polarized 137-MHz beacons of the ATS-1, SIRIO, and Kiku-2 geosynchronous satellites are used to determine the ionospheric corrections to the range and Doppler data for interplanetary spacecraft navigation. The JPL operates the Deep Space Network of tracking stations for NASA; these stations monitor Faraday rotation with dual orthogonal, linearly polarized antennas, Teledyne polarization tracking receivers, analog-to-digital converter/scanners, and other support equipment. Computer software examines the Faraday data, resolves the pi ambiguities, constructs a continuous Faraday-rotation profile and converts the profile to columnar zenith total electron content at the ionospheric reference point; a second program computes the line-of-sight ionospheric correction for each pass of the spacecraft over each tracking complex. Line-of-sight ionospheric electron content using mapped Faraday-rotation data is compared with that using dispersive Doppler data from the Voyager spacecraft; a difference of about 0.4 meters, or 5 x 10 to the 16th electrons/sq m is obtained. The technique of determining the electron content of interplanetary plasma by subtraction of the ionospheric contribution is demonstrated on the plasma torus surrounding the orbit of Io.

  3. Standardising fast-track surgical nursing care in Denmark

    DEFF Research Database (Denmark)

    Hjort Jakobsen, Dorthe; Rud, Kirsten; Kehlet, Henrik

    2014-01-01

    guidelines based on the principles of fast-track surgery-i.e. patient information, surgical stress reduction, effective analgesia, early mobilisation and rapid return to normal eating. Fast-track surgery was introduced systematically in Denmark by the establishment of the Unit of Perioperative Nursing (UPN...

  4. Growth, Faraday and inverse Faraday characteristics of Tb2Ti2O7 crystal.

    Science.gov (United States)

    Guo, Feiyun; Sun, Yilin; Yang, Xiongsheng; Chen, Xin; Zhao, Bin; Zhuang, Naifeng; Chen, Jianzhong

    2016-03-21

    Tb2Ti2O7 (TTO) single crystal with dimensions of 20 × 20 × 16 mm3 was grown by the Czochralski method. Rietveld structure refinement of X-ray diffraction (XRD) data confirms that the compound crystallizes in the cubic system with pyrochlore structure. Transmission spectra, Magnetic circular dichroism (MCD) spectra, Faraday and inverse Faraday characteristics of TTO crystal have been measured and analyzed in detail. The results demonstrate that TTO crystal has high transmittance at 700-1400 nm waveband and a larger Verdat constant than that of TGG reported. Magnetic circular dichroism (MCD) spectra showed that the 4f→4f transitions of Tb3+ have significant contributions to the magneto-optical activity (MOA). In the time-resolved pump-probe spectroscopy, the rotation signals of the probe beam based on the inverse Faraday effect in magneto-optical crystal were observed at zero time delay, the full width at half maximum of the rotation and ellipticity signals can be as fast as ~500 fs, which indicates that TTO crystal can be a promising material for ultrafast all-optical magnetic switching.

  5. Heating profiles on ICRF antenna Faraday shields

    International Nuclear Information System (INIS)

    Taylor, D.J.; Baity, F.W.; Hahs, C.L.; Riemer, B.W.; Ryan, P.M.; Williamson, D.E.

    1991-01-01

    A conceptual design for an uncooled Faraday shield for the BPX ion cyclotron resonance heating (ICRH) antenna, which should withstand the proposed long-pulse operation, has been completed. A high-heat-flux, uncooled Faraday shield has also been designed for the fast-wave current drive (FWCD) antenna on D3-D. For both components, the improved understanding of the heating profiles made it possible to design for heat fluxes that would otherwise have been too close to mechanically established limits. The analytical effort is described in detail, with emphasis on the design work for the BPX ICRH antenna conceptual design and for the replacement Faraday shield for the D3-D FWCD antenna. Results of analyses are shown, and configuration issues involved in component modeling are discussed. 3 refs., 6 figs., 2 tabs

  6. Delirium after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, L S; Hansen, T B

    2012-01-01

    hospital stay and medical morbidity. No data on PD are available in fast-track surgery. The aim of this study was to evaluate the incidence of PD after fast-track hip (THA) and knee arthroplasty (TKA) with anticipated length of stay (LOS) of In a prospective multicentre study to evaluate postoperative...

  7. FAST-TRACK HIP AND KNEE ARTHROPLASTY (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    A. M. Ageenko

    2017-01-01

    Full Text Available In the present paper the authors discuss the history of fast-track formation, its development and current status. Fast-track advantages in comparison to other rehabilitation options are analyzed. The focus is placed on methods of accelerated rehabilitation after total hip and knee arthroplasty in the leading European and American clinics. Fast-track protocols of surgical centers of Denmark and Hospital for special surgery in the US are described, factors that determine time of hospital stay after total hip and knee arthroplasty are considered, predictors of hospital stay and patients satisfaction after the surgery are examined. The paper reflects the results of the comparison of frequency of thromboembolic and other complications as well as readmission rate after traditional rehabilitation and after fast-track. The paper considers fast-track in bilateral total knee replacement. The authors conclude that further research on acceleration of rehabilitation and reduction of hospital stay after total hip and knee arthroplasty needs to be focused on the optimization of pain relief, especially after discharge, blood preservation techniques, supplementation of fluids loss and strengthening of muscles. Literature analysis demonstrated that the implementation of the Protocol for accelerated recovery after joint arthroplasty in Russia is at an insufficient level. Data of foreign multicenter studies during recent years indicate a high efficacy and safety of this technique in different groups of patients.

  8. Fast-Track Teacher Recruitment.

    Science.gov (United States)

    Grant, Franklin Dean

    2001-01-01

    Schools need a Renaissance human-resources director to implement strategic staffing and fast-track teacher-recruitment plans. The HR director must attend to customer satisfaction, candidate supply, web-based recruitment possibilities, stabilization of newly hired staff, retention of veteran staff, utilization of retired employees, and latest…

  9. Fast track pathway for perforated appendicitis.

    Science.gov (United States)

    Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall

    2017-04-01

    Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Fast-Track Management of Patients Undergoing Proximal Pancreatic Resection

    Science.gov (United States)

    French, JJ; Mansfield, SD; Jaques, K; Jaques, BC; Manas, DM; Charnley, RM

    2009-01-01

    INTRODUCTION To avoid the risk of complications of biliary drainage, a feasibility study was carried out to determine whether it might be possible to fast-track surgical treatment, with resection before biliary drainage, in jaundiced patients with proximal pancreatic/peri-ampullary malignancy. PATIENTS AND METHODS Over an 18-month period, based on their presenting bilirubin levels and other logistical factors, all jaundiced patients who might be suitable for fast-track management were identified. Data on complications and hospital stay were compared with those patients in whom a conventional pathway (with biliary drainage) was used during the same time period. Data were also compared with a group of patients from the preceding 6 months. RESULTS Nine patients were fast-tracked and 49 patients treated in the conventional pathway. Fast-track patients mean (SD) serum bilirubin level was 265 μmol/l (81.6) at the time of the operation compared to 43 μmol/l (51.3; P ≥ 0.0001) in conventional patients. Mean (SD) of time from referral to operation, 14 days (9) versus 59 days (36.9), was significantly shorter in fast-track patients than conventional patients (P ≤ 0.0001). Length of hospital stay mean (SD) at 17 (6) days versus 22 days (19.6; P = 0.2114), surgical complications and mortality in fast-track patients were similar to conventional patients. Prior to surgery, the 49 conventional patients underwent a total of 73 biliary drainage procedures resulting in seven major complications. Comparison with the group of patients from the previous 6 months indicated that the conventional group were not disadvantaged. CONCLUSIONS Fast-track management by resection without biliary drainage of selected patients with distal biliary strictures is safe and has the potential to reduce the waiting time to surgery, overall numbers of biliary drainage procedures and the complications thereof. PMID:19220943

  11. Fast tracking in paediatric cardiac anaesthesia : an update.

    Directory of Open Access Journals (Sweden)

    Lake Carol

    2002-01-01

    Full Text Available A care plan in which cardiac surgical patients progress quickly through the perioperative course to hospital discharge is often referred to as a Fast Track. Such care plans have been used extensively in adult cardiac patients but are also applicable to paediatric patients. Although no randomised controlled trials are available to document a reduction in hospital costs and avoidance of iatrogenic complications with paediatric fast tracks, many healthcare administrators encourage their use. Fast Track clinical guidelines usually include same day surgery, use of short- acting anaesthetic drugs, early extubation, effective pain management, and reduced intensive care unit stays. These protocols are certainly appropriate for simple procedures such as repair of atrial or ventricular septal defects or ligation of a patent ductus arteriosus. However, many paediatric cardiac anaesthesiologists consider that all paediatric patients without significant pulmonary or residual cardiac pathology can be managed using expedited postoperative protocols. Essential components in a "fast track" protocol include use of minimally invasive surgical techniques, modified ultrafiltration during cardiopulmonary bypass, transoesophageal echocardiography to evaluate the cardiac repair, and postoperative pain control. Using such techniques, 80-90% of paediatric patients can be extubated in the operating room or within 2-4 hours postoperatively. Despite the opinions of recognised experts, an appropriately sized and powered multicentre, controlled, randomised, prospective study is still needed to conclusively document the efficiency and effectiveness of the Fast Track in paediatric cardiac patients.

  12. Evidence Basis for Regional Anesthesia in Multidisciplinary Fast-Track Surgical Care Pathways

    DEFF Research Database (Denmark)

    Carli, Francesco; Kehlet, Henrik; Baldini, Gabriele

    2011-01-01

    Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type of surge......Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type...... of surgeries. The aim of this article was to identify and discuss potential advantages offerred by regional anesthesia and analgesia techniques to fast-track programs. In the first section, the impact of regional anesthesia on the main elements of fast-track surgery is addressed. In the second section......, procedure-specific fast-track programs for colorectal, hernia, esophageal, cardiac, vascular, and orthopedic surgeries are presented. For each, regional anesthesia and analgesia techniques more frequently used are discussed. Furthermore, clinical studies, which included regional techniques as elements...

  13. Sufentanil Vs Fentanyl for Fast-Track Cardiac Anaesthesia

    Directory of Open Access Journals (Sweden)

    C M Deshpande

    2009-01-01

    Full Text Available A perioperative anaesthetic management that aims to facilitate tracheal extubation of patients within 1-6 hrs after cardiac surgery is called "fast-track′. Main advantage of ′fast-track" method is better usage of medical resources and lowering hospital costs without increasing morbidity and mortality of the patients. Standard fast-track protocols contain short acting anaesthetic agents, smaller incisions and decreased pump times without hypothermia. In this study we compared two short acting opioid drugs, fentanyl versus Sufentanil when used as a part of the balanced anaesthesia technique for fast track in cardiac surgery patients& evaluated the time taken for extubation, haemodynamic stability, analgesia requirements& incidence of awareness. The results from the study show thatboth agents provide good haemodynamic stability and postoperative analgesia. Although Sufentanil provides earlier extuba-tion, both agents reduce the ICU stay equally. In conclusion both agents can be used effectively for fasttrack cardiac anaesthesia.

  14. FTK: a Fast Track Trigger for ATLAS

    International Nuclear Information System (INIS)

    Anderson, J; Auerbach, B; Blair, R; Andreani, A; Andreazza, A; Citterio, M; Annovi, A; Beretta, M; Castegnaro, A; Atkinson, M; Cavaliere, V; Chang, P; Bevacqua, V; Crescioli, F; Blazey, G; Bogdan, M; Boveia, A; Canelli, F; Cheng, Y; Cervigni, F

    2012-01-01

    We describe the design and expected performance of a the Fast Tracker Trigger (FTK) system for the ATLAS detector at the Large Hadron Collider. The FTK is a highly parallel hardware system designed to operate at the Level 1 trigger output rate. It is designed to provide global tracks reconstructed in the inner detector with resolution comparable to the full offline reconstruction as input of the Level 2 trigger processing. The hardware system is based on associative memories for pattern recognition and fast FPGAs for track reconstruction. The FTK is expected to dramatically improve the performance of track based isolation and b-tagging with little to no dependencies of pile-up interactions.

  15. Delirium in the fast-track surgery setting

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, Lars S; Kehlet, Henrik

    2012-01-01

    Postoperative delirium (PD) and postoperative cognitive dysfunction (POCD) are two separate syndromes of cognitive decline after major surgery, especially in the elderly. Pathogenesis is multifactorial with some common risk factors, and to reduce the risk, a multimodal approach is necessary. The ....... In conclusion, the fast-track methodology may reduce the incidence of postoperative cognitive decline after surgery........ The fast-track methodology is becoming a well-established perioperative care regime with possible preventive effects for postoperative cognitive decline, including reduced pain and use of opioids, and early mobilisation with early discharge (≤3 days) to preoperative environment after total hip....../knee arthroplasty (THA/TKA). The fast-track set-up seems to be associated with a lower frequency of PD and early POCD after THA/TKA. Thus, in a series of 225 patients ≥60 years, no cases of PD were seen and the incidence of POCD was reduced by more than 50% at 1 week postoperatively compared to previous studies...

  16. Fast-track knee arthroplasty – status and future challenges

    DEFF Research Database (Denmark)

    Kehlet, Henrik; Thienpont, Emmanuel

    2013-01-01

    Fast-track programs have been developed for different surgical procedures leading to higher patient satisfaction and lower morbidity. This concept has been extended to knee arthroplasty in recent years. The purpose of this narrative review was to discuss the different aspects of fast-track knee...... arthroplasty....

  17. Fast-track surgery: Toward comprehensive peri-operative care.

    Science.gov (United States)

    Nanavati, Aditya J; Prabhakar, S

    2014-01-01

    Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome.

  18. Orchestrating care through the fast-track perspective: A qualitative content analysis of the provision of individualised nursing care in orthopaedic fast-track programmes.

    Science.gov (United States)

    Berthelsen, Connie Bøttcher; Frederiksen, Kirsten

    2017-02-01

    The lack of individualised care in orthopaedic regimes is often explained by the extended use of patient pathways and clinical guidelines. The aim of this study was to illuminate orthopaedic nurses' perceptions and experiences of providing individual nursing care for older patients in standardised fast-track programmes after total hip or knee replacement. Ten semi-structured interviews were conducted with orthopaedic nurses in orthopaedic wards at three Danish hospitals between April and June of 2015. Data were analysed using manifest and latent content analysis according to Graneheim and Lundman. The main theme of the overall interpretation was Orchestrating care through the fast-track perspective, accompanied by three sub-themes: Identifying and legitimising relevant individual care in the fast-track programme, Struggling to fit all patients in the fast-track programme and Justifying individualised care-related actions in the fast-track programme. The study concluded that, even though the nurses struggled to comply with the programme, they still found themselves compromising their nursing care and ethics to follow the standardised regime. There is a need to establish more specific inclusion criteria to maintain the effective elements in the programme and to facilitate nurses' opportunities to offer individual care, thereby ensuring that fragile patients have access to other possibilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Fast-track surgery for breast cancer is possible

    DEFF Research Database (Denmark)

    Mertz, Birgitte G; Kroman, Niels; Williams, Helene

    2013-01-01

    INTRODUCTION: Breast cancer is common among Danish women with more than 4,100 new cases annually. In 2008 the concept of fast-track surgery was introduced at the Department of Breast Surgery at Rigshospitalet, Copenhagen. The aim of this study is to describe the new clinical pathway for breast...... to provide immediate advice and support. CONCLUSION: The results confirm that a short stay can be successfully carried out for breast cancer patients. Implementing the fast-track programme involved the introduction of a clear clinical pathway for the patients and more effective daily routines. Patients felt...... cancer patients after implementation of a fast-track surgery programme. MATERIAL AND METHODS: A clinical pathway of all involved disciplines was developed including anaesthetic, analgesics, nausea and vomiting, drain and wound management, discharge assessment and psychosocial support. RESULTS...

  20. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    Science.gov (United States)

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  1. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    International Nuclear Information System (INIS)

    Chen, J.; Ding, W. X.; Brower, D. L.; Finkenthal, D.; Muscatello, C.; Taussig, D.; Boivin, R.

    2016-01-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  2. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    DEFF Research Database (Denmark)

    Burgdorf, Stefan K; Rosenberg, Jacob

    2012-01-01

    Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks...... care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic...... in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we aimed to reduce hospitalisation without increasing cost in nursing staff per hospital bed. Length of stay...

  3. Fast-track Orthognathic Surgery: An Evidence-based Review

    Science.gov (United States)

    Otero, Joel Joshi; Detriche, Olivier; Mommaerts, Maurice Yves

    2017-01-01

    The aim of this study was to establish a fast-track protocol for bimaxillary orthognathic surgery (OGS). Fast-track surgery (FTS) is a multidisciplinary approach where the pre-, intra-, and postoperative management is focusing maximally on a quick patient recovery and early discharge. To enable this, the patients’ presurgical stress and postsurgical discomfort should be maximally reduced. Both referral patterns and expenses within the health-care system are positively influenced by FTS. University hospital-literature review through Medline, Embase, and the Cochrane Library (January 2000–July 2016) using the following words – “fast track, enhanced recovery, multimodal, and perioperative care” – to define a protocol evidence based for OGS, as well as evidenced-based medicine search of every term added to the protocol during the same period. The process has resulted in an OGS protocol that may improve the outcome of the patient through several nonoperative and operative measures such as preoperative patient education and intra/postoperative measures that should improve overall patient satisfaction, decrease morbidity such as postoperative nausea, headache, dizziness, pain, and intubation discomfort, and shorten hospital stay. A literature review allowed us to fine-tune a fast-track protocol for uncomplicated OGS that can be prospectively studied against currently applied ones. PMID:29264281

  4. Evidence Basis for Regional Anesthesia in Multidisciplinary Fast-Track Surgical Care Pathways

    DEFF Research Database (Denmark)

    Carli, Francesco; Kehlet, Henrik; Baldini, Gabriele

    2011-01-01

    Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type...... of surgeries. The aim of this article was to identify and discuss potential advantages offerred by regional anesthesia and analgesia techniques to fast-track programs. In the first section, the impact of regional anesthesia on the main elements of fast-track surgery is addressed. In the second section......, procedure-specific fast-track programs for colorectal, hernia, esophageal, cardiac, vascular, and orthopedic surgeries are presented. For each, regional anesthesia and analgesia techniques more frequently used are discussed. Furthermore, clinical studies, which included regional techniques as elements...

  5. Safety of fast track surgery in pancreaticoduodenectomy: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    LI Weinan

    2017-01-01

    Full Text Available ObjectiveTo investigate the safety and clinical effect of fast track surgery in pancreaticoduodenectomy, one of the most complex surgeries in general surgery. MethodsThe Chinese and foreign databases were searched for articles on the application of fast tract surgery in pancreaticoduodenectomy published from January 1994 to April 2016. Two researchers evaluated the quality of the articles which met the inclusion criteria and extracted related data. Stata 12.0 software was used to analyze the overall incidence rate of complications and the incidence rates of pancreatic leakage and gastrointestinal emptying disorder, and the Begg rank correlation test and Egger linear regression method were used to investigate publication bias. ResultsThe fast track surgery group had a significantly lower overall incidence rate of complications than the conventional group (RR=0.748, 95%CI: 0.680-0.824, P<0.001. There was no significant difference in the incidence rate of pancreatic leakage between the two groups (RR=0.894, 95%CI:0.734-1.089, P=0.266. The fast track surgery group had a significantly lower incidence rate of gastrointestinal emptying disorder than the conventional group (RR=0.520, 95%CI:0.400-0.670, P<0.001. ConclusionFast track surgery is safe and effective in pancreaticoduodenectomy, but the application of some measures in fast track surgery still needs more medical evidence.

  6. Faraday instability and Faraday patterns in a superfluid Fermi gas

    International Nuclear Information System (INIS)

    Tang Rongan; Xue Jukui; Li Haocai

    2011-01-01

    With the consideration of the coupling between the transverse width and the longitudinal density, the parametric excitations related to Faraday waves in a cigar-shaped superfluid Fermi gas are studied. A Mathieu equation is obtained, and it is demonstrated firstly that the excited actual 3D Faraday pattern is the combination of the longitudinal Faraday density wave and the corresponding transverse width fluctuation in the longitudinal direction. The Faraday instability growth index and the kinematic equations of the Faraday density wave and the width fluctuation along the Bose-Einstein condensate (BEC)-Bardeen-Cooper-Schrieffer (BCS) crossover are also given for the first time. It is found that the 3D Faraday pattern presents quite different behaviours (such as the excitations and the motions) when the system crosses from the BEC side to the BCS side. The coupling not only plays an important role in the parametric excitation, but also determines the dominant wavelength of the spatial structure. Along the crossover, the coupling effects are more significant in the BCS side. The final numerical investigation verifies these results and gives a detailed study of the parametric excitations (i.e. Faraday instability) and the 3D pattern formation.

  7. Bilateral simultaneous total hip arthroplasty in a fast track setting

    DEFF Research Database (Denmark)

    Otte, Kristian S; Husted, Henrik; Ørsnes, Thue

    2011-01-01

    and low complication rates when performed in a fast-track setting. We believed it would be useful to assess hip arthroplasty in this context, and we report 50 consecutive fast-track simultaneous bilateral hip arthroplasty procedures. The median length of stay was 4 days. Mortality within 90 days was 4......% and 8% required a further operative procedure. The overall complication rate was 22%. 55% of the complications were considered to be caused by failures in surgical technique and 45% by other factors. Bilateral simultaneous hip arthroplasty may have a high complication rate in a fast-track setting...

  8. Care principles at four fast-track arthroplasty departments in Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Solgaard, Søren; Hansen, Torben B

    2010-01-01

    The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery.......The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery....

  9. ATLAS FTK Fast Track Trigger

    CERN Document Server

    Iizawa, T; The ATLAS collaboration

    2014-01-01

    The Fast TracKer (FTK) will perform global track reconstruction after each Level-1 trigger accept signal to enable the software-based higher level trigger to have early access to tracking information. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful Field Programmable Gate Arrays (FPGAs) form an important part of the system architecture, and the large level of computing power required for pattern recognition is provided by incorporating standard-cell ASICs named Associative Memory (AM). Motivation and the architecture of the FTK system will be presented, and the status of hardware and simulation will be following.

  10. Nursing care in fast-track surgery strategy

    Directory of Open Access Journals (Sweden)

    Dorota Kozieł

    2015-10-01

    Full Text Available In recent years, many study results have been published confirming an improvement in the outcomes of treatment related with management of patients within the fast-track surgery programme. Early postoperative rehabilitation is possible provided there is engagement of a multi-disciplinary team, including well-educated nurses. Today, a diversion can be observed from traditional nursing on behalf of a coordinated, holistic approach, while more attention is paid to the, thus far marginalised, psychosocial aspects of care. The objective of the study is to discuss the basic assumptions of fast track surgery with respect to nursing care, with particular emphasis placed on the educational function. Modern nursing within the short-track surgery programme should focus on the provision of patients with care consisting of preliminary information concerning the perioperative period, social and psychological support, counselling in the area of home convalescence, and procedures in the case of complications.

  11. Which fast track elements predict early recovery after colon cancer surgery?

    NARCIS (Netherlands)

    Vlug, M. S.; Bartels, S. A. L.; Wind, J.; Ubbink, D. T.; Hollmann, M. W.; Bemelman, W. A.; Sprangers, Mirjam; Preckel, Benedikt; Bossuyt, Patrick; Gouma, Dirk; van Berge Henegouwen, Mark; Fuhring, Jan; Lenthe, Ineke Picard-van; Bakker, Chris; King-Kalimanis, Bellinda; Hofland, Jan; Dejong, Cornelis; van Dam, Ronald; Cuesta, Miguel; van der Peet, Donald; van Zalingen, Edith; Noordhuis, Astrid; de Jong, Dick; Engel, Alexander; Goei, T. Hauwy; de Stoppelaar, Erica; van den Dongen, Marjon; van Wagensveld, Bart; van Tets, Willem; van den Elsen, Maarten; Swart, Annemiek; Gerhards, Michael; de Wit, Laurens; Siepel, Muriel; Molly, Glaresa; Gasthuis, Onze Lieve Vrouwe; van Geloven, Anna; Juttmann, Jan; Clevers, Wilfred; Bieleman, Andrea; van der Zaag, Edwin; Coenen, Ludo; Bonekamp, Elly; Cense, Huib; van Abeelen, Jacobus; van Iterson-de Jong, Diana; Krombeen, Margriet

    2012-01-01

    Aim It is questioned whether all separate fast track elements are essential for enhanced postoperative recovery. We aimed to determine which baseline characteristics and which fast track elements are independent predictors of faster postoperative recovery in patients undergoing resection for colon

  12. Biology's built-in Faraday cages

    Science.gov (United States)

    Klee, Maurice M.

    2014-05-01

    Biological fluids are water-based, ionic conductors. As such, they have both high relative dielectric constants and substantial conductivities, meaning they are lossy dielectrics. These fluids contain charged molecules (free charges), whose movements play roles in essentially all cellular processes from metabolism to communication with other cells. Using the problem of a point source in air above a biological fluid of semi-infinite extent, the bound charges in the fluid are shown to perform the function of a fast-acting Faraday cage, which protects the interior of the fluid from external electric fields. Free charges replace bound charges in accordance with the fluid's relaxation time, thereby providing a smooth transition between the initial protection provided by the bound charges and the steady state protection provided by the free charges. The electric fields within the biological fluid are thus small for all times just as they would be inside a classical Faraday cage.

  13. An artificial retina for fast track finding

    International Nuclear Information System (INIS)

    Ristori, Luciano

    2000-01-01

    A new approach is proposed for fast track finding in position-sensitive detectors. The basic working principle is modeled on what is widely believed to be the low-level mechanism used by the eye to recognize straight edges. A number of receptors are tuned such that each one responds to a different range of track orientations, each track actually fires several receptors and an estimate of the orientation is obtained through interpolation. The feasibility of a practical device based on this principle and its possible implementation using currently available digital logic is discussed

  14. PREDICTING A FAST-TRACK MARITIME CAREER: CHARACTERISTICS OF SUCCESSFUL OFFICERS DURING TEENAGE YEARS

    Directory of Open Access Journals (Sweden)

    Manuel Joaquín Fernández González

    2017-12-01

    Full Text Available Fast-track maritime career is a topical question worldwide due to the shortage of seafarers in maritime industry. Assuming that the fast-track career officers’ relevant common characteristics in adolescence could predict future maritime career speed, the research questions of this research are: What were the common characteristics of fast-track career officers when they were 16-18? Were there any statistically significant differences between the fast-track career groups and the officers with a slower career at that age? A questionnaire survey involving 175 maritime officers was conducted in Latvia in January – October 2016, regarding officers’ family context, school achievement, involvement in sports, and personality traits when they were 16-18. Fast-track career officers perceived themselves as more conscientious, calm and more leadership oriented than the whole group in adolescence. Statistically significant differences among career-speed groups were found regarding family socioeconomic status, family atmosphere and family career support at that age. Based on those communalities among maritime officers with a fast-track carrier when they were 16-18, maritime education and training institutions could better find and give appropriate career guidance to prospective maritime officers. Even if maritime career speed is a very individualized phenomenon, family characteristics could be studied further as a potential good predictor of fast-track maritime career.

  15. An Improved Fast Compressive Tracking Algorithm Based on Online Random Forest Classifier

    Directory of Open Access Journals (Sweden)

    Xiong Jintao

    2016-01-01

    Full Text Available The fast compressive tracking (FCT algorithm is a simple and efficient algorithm, which is proposed in recent years. But, it is difficult to deal with the factors such as occlusion, appearance changes, pose variation, etc in processing. The reasons are that, Firstly, even if the naive Bayes classifier is fast in training, it is not robust concerning the noise. Secondly, the parameters are required to vary with the unique environment for accurate tracking. In this paper, we propose an improved fast compressive tracking algorithm based on online random forest (FCT-ORF for robust visual tracking. Firstly, we combine ideas with the adaptive compressive sensing theory regarding the weighted random projection to exploit both local and discriminative information of the object. The second reason is the online random forest classifier for online tracking which is demonstrated with more robust to the noise adaptively and high computational efficiency. The experimental results show that the algorithm we have proposed has a better performance in the field of occlusion, appearance changes, and pose variation than the fast compressive tracking algorithm’s contribution.

  16. "Fast Track" and "Traditional Path" Coaches: Affordances, Agency and Social Capital

    Science.gov (United States)

    Rynne, Steven

    2014-01-01

    A recent development in large-scale coach accreditation (certification) structures has been the "fast tracking" of former elite athletes. Former elite athletes are often exempted from entry-level qualifications and are generally granted access to fast track courses that are shortened versions of the accreditation courses undertaken by…

  17. Fast-track surgery-an update on physiological care principles to enhance recovery

    DEFF Research Database (Denmark)

    Kehlet, Henrik

    2011-01-01

    INTRODUCTION: The concept of fast-track surgery (enhanced recovery programs) has been evolved and been documented to be successful by decreasing length of stay, morbidity and convalescence across procedures. FUTURE STRATEGIES: However, there are several possibilities for further improvement of mo...... of the components of fast-track surgery, where surgical stress, fluid and pain management are key factors. There is an urgent need for better design of studies, especially in minimal invasive surgery to achieve maximal outcome effects when integrated into the fast-track methodology....

  18. Postoperative morbidity after fast-track laparoscopic resection of rectal cancer

    DEFF Research Database (Denmark)

    Stottmeier, S; Harling, H; Wille-Jørgensen, Peer Anders

    2012-01-01

    Aim: Analysis was carried out of the nature and chronological order of early complications after fast-track laparoscopic rectal surgery with a view to optimize the short-time outcome of rectal cancer surgery. Method: 102 consecutive patients who underwent elective fast-track laparoscopic rectal......: Postoperative morbidity remains a significant problem even in the fast-track era, even in experienced surgical hands. Our results suggest that besides improvement of surgical technique further improvement of outcome lies in early recognition and proper treatment of complications and the perioperative...... cancer surgery were analysed prospectively from the Danish Colorectal Cancer Database supplemented by data from the medical records. We studied in detail the nature and chronological order of postoperative morbidity and reason for prolonged stay (>5 days). Results: Twenty-five patients (25 per cent) had...

  19. Orchestrating care through the fast-track perspective: Orthopaedic nurses’ perceptions and experiences of providing individualised nursing care in older patients’ standardised fast-track programmes after total hip or knee replacement

    DEFF Research Database (Denmark)

    Bøttcher Berthelsen, Connie; Frederiksen, Kirsten

    2017-01-01

    The lack of individualised care in orthopaedic regimes is often explained by the extended use of patient pathways and clinical guidelines. The aim of this study was to illuminate orthopaedic nurses' perceptions and experiences of providing individual nursing care for older patients in standardised...... fast-track programmes after total hip or knee replacement. Ten semi-structured interviews were conducted with orthopaedic nurses in orthopaedic wards at three Danish hospitals between April and June of 2015. Data were analysed using manifest and latent content analysis according to Graneheim...... and Lundman. The main theme of the overall interpretation was Orchestrating care through the fast-track perspective, accompanied by three sub-themes: Identifying and legitimising relevant individual care in the fast-track programme, Struggling to fit all patients in the fast-track programme and Justifying...

  20. TRACKING TESTS FOR THE SNS FAST INJECTION BUMP POWER SUPPLY

    International Nuclear Information System (INIS)

    ENG, W.; CUTLER, R.; DEWAN, S.

    2004-01-01

    The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper

  1. A blueprint for multidisciplinary fast track gastrointestinal oncology care

    NARCIS (Netherlands)

    Basta, Y.L.

    2017-01-01

    In this thesis, we have evaluated the implementation of two key concepts of the Gastro Intestinal oncology Center Amsterdam (GIOCA): multidisciplinary teams (MDT) and the fast delivery of care in fast track clinics (FTC). The first part of this thesis investigates the value of multidisciplinary

  2. Effect of an Emergency Department Fast Track on Press-Ganey Patient Satisfaction Scores

    Directory of Open Access Journals (Sweden)

    Hwang, Calvin E.

    2014-12-01

    Full Text Available Introduction: Mandated patient surveys have become an integral part of Medicare remuneration, putting hundreds of millions of dollars in funding at risk. The Centers for Medicare & Medicaid Services (CMS recently announced a patient experience survey for the emergency department (ED. Development of an ED Fast Track, where lower acuity patients are rapidly seen, has been shown to improve many of the metrics that CMS examines. This is the first study examining if ED Fast Track implementation affects Press-Ganey scores of patient satisfaction. Methods: We analyzed returned Press-Ganey questionnaires from all ESI 4 and 5 patients seen 11AM - 11PM, August-December 2011 (pre-fast track, and during the identical hours of fast track, August-December 2012. Raw ordinal scores were converted to continuous scores for paired student t-test analysis. We calculated an odds ratio with 100% satisfaction considered a positive response. Results: An academic ED with 52,000 annual visits had 140 pre-fast track and 85 fast track respondents. Implementation of a fast track significantly increased patient satisfaction with the following: wait times (68% satisfaction to 88%, OR 4.13, 95% CI [2.32-7.33], doctor courtesy (90% to 95%, OR 1.97, 95% CI [1.04-3.73], nurse courtesy (87% to 95%, OR 2.75, 95% CI [1.46-5.15], pain control (79% to 87%, OR 2.13, 95% CI [1.16-3.92], likelihood to recommend (81% to 90%, OR 2.62, 95% CI [1.42-4.83], staff caring (82% to 91%, OR 2.82, 95% CI [1.54-5.19], and staying informed about delays (66% to 83%, OR 3.00, 95% CI [1.65-5.44]. Conclusion: Implementation of an ED Fast Track more than doubled the odds of significant improvements in Press-Ganey patient satisfaction metrics and may play an important role in improving ED performance on CMS benchmarks. [West J Emerg Med. 2015;16(1:34–38.

  3. Evidence-based surgical care and the evolution of fast-track surgery

    DEFF Research Database (Denmark)

    Kehlet, H.; Wilmore, D.W.

    2008-01-01

    , randomized studies, and meta-analyses, the concept of the "fast-track methodology" has uniformly provided a major enhancement in recovery leading to decreased hospital stay and with an apparent reduction in medical morbidity but unaltered "surgery-specific" morbidity in a variety of procedures. However......BACKGROUND: Optimization of postoperative outcome requires the application of evidence-based principles of care carefully integrated into a multimodal rehabilitation program. OBJECTIVE: To assess, synthesize, and discuss implementation of "fast-track" recovery programs. DATA SOURCES: Medline MBASE...... (January 1966-May 2007) and the Cochrane library (January 1966-May 2007) were searched using the following keywords: fast-track, enhanced recovery, accelerated rehabilitation, and multimodal and perioperative care. In addition, the synthesis on the many specific interventions and organizational...

  4. The Danish Head and Neck Cancer fast-track program

    DEFF Research Database (Denmark)

    Roennegaard, Anders B.; Rosenberg, Tine; Bjørndal, Kristine

    2018-01-01

    -track clinical pathway solutions. Objectives: The objectives of this study were 1) to present the setup of the head and neck cancer (HNC) fast-track program at Odense University Hospital (OUH) as an example of the Danish model and 2) to present patient characteristics, diagnostic outcome, cancer detection rate...

  5. Second Generation of a Fast-track Liver Resection Programme

    DEFF Research Database (Denmark)

    Schultz, Nicolai A; Larsen, Peter N; Klarskov, B

    2018-01-01

    was given to all patients before surgery, catheters and drains were systematically removed early, and patients were mobilized and started eating and drinking from the day of surgery. An opioid-sparing multimodal pain treatment was given for the first week. The discharge criteria were (1) pain sufficiently....... The readmission rate was 6% and the 30-day mortality zero. The LOS decreased compared to our first-generation fast-track programme with LOS 5 days. CONCLUSIONS: Fast-track principles for perioperative care and early discharge are safe even after major liver resection. The introduction of high-dose steroids...

  6. Wave-particle interaction in the Faraday waves.

    Science.gov (United States)

    Francois, N; Xia, H; Punzmann, H; Shats, M

    2015-10-01

    Wave motion in disordered Faraday waves is analysed in terms of oscillons or quasi-particles. The motion of these oscillons is measured using particle tracking tools and it is compared with the motion of fluid particles on the water surface. Both the real floating particles and the oscillons, representing the collective fluid motion, show Brownian-type dispersion exhibiting ballistic and diffusive mean squared displacement at short and long times, respectively. While the floating particles motion has been previously explained in the context of two-dimensional turbulence driven by Faraday waves, no theoretical description exists for the random walk type motion of oscillons. It is found that the r.m.s velocity ⟨μ̃(osc)⟩(rms) of oscillons is directly related to the turbulent r.m.s. velocity ⟨μ̃⟩(rms) of the fluid particles in a broad range of vertical accelerations. The measured ⟨μ̃(osc)⟩(rms) accurately explains the broadening of the frequency spectra of the surface elevation observed in disordered Faraday waves. These results suggest that 2D turbulence is the driving force behind both the randomization of the oscillons motion and the resulting broadening of the wave frequency spectra. The coupling between wave motion and hydrodynamic turbulence demonstrated here offers new perspectives for predicting complex fluid transport from the knowledge of wave field spectra and vice versa.

  7. Michael Faraday vs. the Spiritualists

    Science.gov (United States)

    Hirshfeld, Alan

    2006-12-01

    In the 1850s, renowned physicist Michael Faraday launched a public campaign against pseudoscience and spiritualism, which were rampant in England at the time. Faraday objected especially to claims that electrical or magnetic forces were responsible for paranormal phenomena, such as table-spinning and communication with the dead. Using scientific methods, Faraday unmasked the deceptions of spiritualists, clairvoyants and mediums and also laid bare the credulity of a public ill-educated in science. Despite his efforts, Victorian society's fascination with the paranormal swelled. Faraday's debacle anticipates current controversies about public science education and the interface between science and religion. This episode is one of many described in the new biography, The Electric Life of Michael Faraday (Walker & Co.), which chronicles Faraday's discoveries and his unlikely rise from poverty to the pinnacle of the English science establishment.

  8. Pathogenesis of morbidity after fast-track laparoscopic colonic cancer surgery

    DEFF Research Database (Denmark)

    Stottmeier, S; Harling, H; Wille-Jørgensen, P

    2011-01-01

    AIM: Analysis of the nature and time course of early complications after laparoscopic colonic surgery is required to allow rational strategies for their prevention and management. METHOD: One hundred and four consecutive patients who underwent elective fast-track laparoscopic colonic cancer surgery...... occurred in 14 patients, of which four were preceded by medical complications. Three patients had only medical complications. Median length of stay was 3 days (range 1-44). CONCLUSION: Further improvement of outcomes after fast-track laparoscopic colonic surgery might be obtained by improved surgical...

  9. Fast-track rehabilitation in elective colorectal surgery patients: a prospective clinical and immunological single-centre study.

    Science.gov (United States)

    Wichmann, Matthias W; Eben, Ricarda; Angele, Martin K; Brandenburg, Franzis; Goetz, Alwin E; Jauch, Karl-Walter

    2007-07-01

    Recent clinical data indicate that fast-track surgery (multimodal rehabilitation) leads to shorter postoperative length of hospital stay, faster recovery of gastrointestinal function as well as reduced morbidity and mortality rates. To date, no study has focused on the effects of fast-track surgery on postoperative immune function. This study was initiated to determine whether fast-track rehabilitation results in improved clinical and immunological outcome of patients undergoing colorectal surgery. Forty patients underwent either conventional or fast-track rehabilitation after colorectal surgery. In addition to clinical parameters (return of gastrointestinal function, food intake, pain score, complication rates and postoperative length of stay), we determined parameters of perioperative immunity by flow cytometry (lymphocyte subgroups) and enzyme-linked immunosorbent assay (interleukin-6). Our findings indicate a better-preserved cell-mediated immune function (T cells, T-helper cells, natural killer cells) after fast-track rehabilitation, whereas the pro-inflammatory response (C-reactive protein, interleukin-6) was unchanged in both study groups. Furthermore, we detected a significantly faster return of gastrointestinal function (first bowel movement P<0.001, food intake P<0.05), significantly reduced pain scores in the postoperative course (P < 0.05) and a significantly shorter length of postoperative stay (P<0.001) in patients undergoing fast-track rehabilitation. Fast-track rehabilitation after colorectal surgery results in better-preserved cell-mediated immunity when compared with conventional postoperative care. Furthermore, patients undergoing fast-track rehabilitation suffer from less pain and have a faster return of gastrointestinal function in the postoperative course. In addition, postoperative length of hospital stay was significantly shorter in fast-track patients.

  10. Stripline fast faraday cup for measuring GHz structure of ion beams

    International Nuclear Information System (INIS)

    Bogaty, J.M.

    1992-01-01

    This patent describes an apparatus for measuring the structure on ion beams. It comprises a dielectric strip with an opening therethrough to create an air gap from one side of the dielectric strip to the other; a conductive stripeline bonded to one side of the dielectric strip and a groundplane bonded to the opposing side of the dielectric strip wherein the airgap remains open; a thin dielectric film coating the groundplane; a second groundplane adhering to the thin dielectric film wherein a portion of the thin dielectric film adjacent to the air gap is exposed; a fine mesh electrostatic screen bonded to the second groundplane directly over the air gap; means for matching the impedance at the electrostatic screen with that of the stripline; a Faraday cup mounted opposite the electrostatic screen with a drift space between the electrostatic screen and the Faraday cup; means for reducing RF reflections from the stripline through the use of a terminating impedance; means for biasing the electrostatic screen; means for outputting information to an amplifier; and a measuring device coupled to the amplifier where the measuring device receives information from the amplifier

  11. Broadband Faraday isolator.

    Science.gov (United States)

    Berent, Michał; Rangelov, Andon A; Vitanov, Nikolay V

    2013-01-01

    Driving on an analogy with the technique of composite pulses in quantum physics, we theoretically propose a broadband Faraday rotator and thus a broadband optical isolator, which is composed of sequences of ordinary Faraday rotators and achromatic quarter-wave plates rotated at the predetermined angles.

  12. The role of pain for early rehabilitation in fast track total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Myhrmann, Lis

    2010-01-01

    To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA).......To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA)....

  13. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    Directory of Open Access Journals (Sweden)

    Lene Bastrup Jørgensen

    2016-01-01

    Full Text Available Aims and objectives: The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background: Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design: The study design used classical grounded theory. Methods: The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results: Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion: In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  14. Restoring integrity--A grounded theory of coping with a fast track surgery programme.

    Science.gov (United States)

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. The study design used classical grounded theory. The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients' main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  15. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    Science.gov (United States)

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    Aims and objectives The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design The study design used classical grounded theory. Methods The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme. PMID:26751199

  16. Fast emulation of track reconstruction in the CMS simulation

    CERN Document Server

    Komm, Matthias

    2017-01-01

    Simulated samples of various physics processes are a key ingredient within analyses to unlock the physics behind LHC collision data. Samples with more and more statistics are required to keep up with the increasing amounts of recorded data. During sample generation, significant computing time is spent on the reconstruction of charged particle tracks from energy deposits which additionally scales with the pileup conditions. In CMS, the FastSimulation package is developed for providing a fast alternative to the standard simulation and reconstruction workflow. It employs various techniques to emulate track reconstruction effects in particle collision events. Several analysis groups in CMS are utilizing the package, in particular those requiring many samples to scan the parameter space of physics models (e.g. SUSY) or for the purpose of estimating systematic uncertainties. The strategies for and recent developments in this emulation are presented, including a novel, flexible implementation of tracking emulation w...

  17. Accelerated Leadership Development: Fast Tracking School Leaders

    Science.gov (United States)

    Earley, Peter; Jones, Jeff

    2010-01-01

    "Accelerated Leadership Development" captures and communicates the lessons learned from successful fast-track leadership programmes in the private and public sector, and provides a model which schools can follow and customize as they plan their own leadership development strategies. As large numbers of headteachers and other senior staff…

  18. Fast-track program vs traditional care in surgery for gastric cancer.

    Science.gov (United States)

    Chen, Zhi-Xing; Liu, Ae-Huey Jennifer; Cen, Ying

    2014-01-14

    To systematically review the evidence for the effectiveness of fast-track program vs traditional care in laparoscopic or open surgery for gastric cancer. PubMed, Embase and the Cochrane library databases were electronically searched for published studies between January 1995 and April 2013, and only randomized trials were included. The references of relevant studies were manually searched for further studies that may have been missed. Search terms included "gastric cancer", "fast track" and "enhanced recovery". Five outcome variables were considered most suitable for analysis: postoperative hospital stay, medical cost, duration to first flatus, C-reactive protein (CRP) level and complications. Postoperative hospital stay was calculated from the date of operation to the date of discharge. Fixed effects model was used for meta-analysis. Compared with traditional care, fast-track program could significantly decrease the postoperative hospital stay [weighted mean difference (WMD) = -1.19, 95%CI: -1.79--0.60, P = 0.0001, fixed model], duration to first flatus (WMD = -6.82, 95%CI: -11.51--2.13, P = 0.004), medical costs (WMD = -2590, 95%CI: -4054--1126, P = 0.001), and the level of CRP (WMD = -17.78, 95%CI: -32.22--3.35, P = 0.0001) in laparoscopic surgery for gastric cancer. In open surgery for gastric cancer, fast-track program could also significantly decrease the postoperative hospital stay (WMD = -1.99, 95%CI: -2.09--1.89, P = 0.0001), duration to first flatus (WMD = -12.0, 95%CI: -18.89--5.11, P = 0.001), medical cost (WMD = -3674, 95%CI: -5025--2323, P = 0.0001), and the level of CRP (WMD = -27.34, 95%CI: -35.42--19.26, P = 0.0001). Furthermore, fast-track program did not significantly increase the incidence of complication (RR = 1.39, 95%CI: 0.77-2.51, P = 0.27, for laparoscopic surgery; and RR = 1.52, 95%CI: 0.90-2.56, P = 0.12, for open surgery). Our overall results suggested that compared with traditional care, fast-track program could result in shorter

  19. Successful integration of fast track projects into turnarounds

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J. Patrick; Loureiro, Ramon C. [KBC Advanced Technologies, Surrey (United Kingdom)

    2012-07-01

    Fast track projects can provide quick wins and competitive advantage. However, in most cases the implementation of these projects requires a shutdown for installing the necessary tie-ins or integration into an upcoming turnaround (TA). Depending on the nature of the project and complexity of the TA, the integration can be seamless or result in cost or duration overruns and safety incidents. The risk of such overruns and safety incidents increases with the amount of project work to be integrated into the operations, maintenance and inspection schedules to be executed during the TA. The risk further increases with TA size and other factors. If not planned and scheduled properly and in a timely fashion, capital projects, in particular fast track projects trying to take advantage of an upcoming TA, can severely impact both TA performance, and the safety and reliability of the facility until the next opportunity for eliminating the defects introduced during the TA. Successful TAs are those delivered in a safe, on time, on budget manner, and with the quality standards needed for a leak-free start-up and a safe and reliable operation over the next run cycle. This paper discusses the key elements that are required to minimize the TA risks derived from the inclusion of fast track projects and how to establish the cut off criteria to either cancel or defer the project, or delay the TA in order to balance TA scope freeze and the case for compelling economics.(author)

  20. Fast and Practical Head Tracking in Brain Imaging with Time-of-Flight Camera

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Jensen, Rasmus Ramsbøl

    2013-01-01

    scanners. Particularly in MRI and PET, the newest generation of TOF cameras could become a method of tracking small and large scale patient movement in a fast and user friendly way required in clinical environments. We present a novel methodology for fast tracking from TOF point clouds without the need...

  1. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  2. Michael Faraday's Bicentenary.

    Science.gov (United States)

    Williams, L. Pearce; And Others

    1991-01-01

    Six articles discuss the work of Michael Faraday, a chemist whose work revolutionized physics and led directly to both classical field and relativity theory. The scientist as a young man, the electromagnetic experiments of Faraday, his search for the gravelectric effect, his work on optical glass, his laboratory notebooks, and his creative use of…

  3. Optical isolation by Faraday rotator

    International Nuclear Information System (INIS)

    Kasai, Takeshi; Matsushima, Isao; Nemoto, Fusashi; Yano, Masaaki

    1984-01-01

    Three Faraday rotators designed as optical isolators in a high power glass laser system are described. The spatial fluctuation of applied magnetic field is less than 1% throughout the Faraday glass rod. The Faraday rotators transmit more than 80% of the forward-going laser light and reject more than 96% of the backward-going light. (author)

  4. Comparison of remifentanil and low-dose fentanyl for fast-track cardiac anesthesia

    DEFF Research Database (Denmark)

    Khanykin, Boris; Siddiqi, Rizwan; Jensen, Per F

    2013-01-01

    BACKGROUND: Different anesthetic techniques have been used for fast tracking in cardiac anesthesia. Remifentanil, with its unique pharmacokinetic profile, could be an ideal drug for fast tracking. Possible limitations of remifentanil are rapid onset of postoperative pain after discontinuation...... of the drug infusion, which may increase the risk of an ischemic event. We conducted this randomized study to compare the efficacy of remifentanil versus low doses of fentanyl in fast-track cardiac anesthesia. It has been hypothesized that remifentanil would provide a safe anesthesia with no impact...... anesthesia. The study was designed as a prospective randomized study. The primary outcomes were changes in the cardiac index and creatine kinase MB fraction (CKMB), extubation times, mobilization times, and lengths of stay in the intensive care unit (ICU) and the hospital. Frequency of myocardial infarction...

  5. PUC fast track nips returns

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the first of what it says will be annual cost-of-capital proceedings to set returns on equity and rates of return on rate base for electric utilities, the California Public Utilities Commission (PUC) lowered from 1989 levels the 1990 returns on common equity (ROE) and rates of return (ROR) for the state's four major investor-owned electric utilities. Under this fast-track procedure, by May 8 of every year, utilities will have to file an application for rate adjustments that reflect their projected costs of capital for the following year

  6. Measurement of the current in water discharge using magneto-optical Faraday effect

    International Nuclear Information System (INIS)

    Sarkisov, G.S.; Woodworth, J.R.

    2006-01-01

    The observation of magnetooptical Faraday effects in water in experiments with electrical breakdown is presented. After high-voltage breakdown, the ionized channel with ∼4 kA current was generated. The magnetic field from the current channel induces a circular birefringence which results in rotation of the polarization plane of a probing laser (200 ps, 532 nm). In spite of fast opposite radius drop of the magnetic field in radial direction, the Faraday rotation effect drops very slowly. The rotation of the polarization plane was ∼0.65 deg. ±5%. The optical measurements are in good agreement within ∼7% with the electrical measurements of the current

  7. Trevino Project: a fast-track approach for a small construction project

    International Nuclear Information System (INIS)

    Schick, C.J.; Lynn, N.S.

    1982-01-01

    The approach to a construction project can vary according to the size, location, and degree of difficulty associated with the project. This paper deals with one approach that can be taken to a small construction project, the fast-track approach. A small construction project can be defined as a project having less than $20 million capital cost or a project with a low degree of difficulty. This approach is very applicable to in-situ leaching uranium projects, small precious metal operations, etc. The approach to the small project is that of fast-tracking the project in order to minimize the time over which capital expenditure occurs and also to reduce the indirect costs of field expense, construction supplies, construction equipment, etc. In order to fast-track a project it is necessary to do a very precise job on the preliminary phases of the project such as preliminary engineering, plant site location, environmental permits, etc. 2 figures, 2 tables

  8. The risk of manipulation under anesthesia due to unsatisfactory knee flexion after fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Wied, Christian; Thomsen, Morten G; Kallemose, Thomas

    2015-01-01

    BACKGROUND: Fast-track TKA has significantly shortened the time available for physiotherapists to optimize knee ROM before discharge. Safety aspects concerning knee stiffness and the need for manipulation in a fast-track setting need to be illuminated. The study aims were to analyze if fast-track...

  9. Time-driven Activity-based Cost of Fast-Track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Andreasen, Signe E; Holm, Henriette B; Jørgensen, Mira

    2017-01-01

    this between 2 departments with different logistical set-ups. METHODS: Prospective data collection was analyzed using the time-driven activity-based costing method (TDABC) on time consumed by different staff members involved in patient treatment in the perioperative period of fast-track THA and TKA in 2 Danish...... orthopedic departments with standardized fast-track settings, but different logistical set-ups. RESULTS: Length of stay was median 2 days in both departments. TDABC revealed minor differences in the perioperative settings between departments, but the total cost excluding the prosthesis was similar at USD......-track methodology, the result could be a more cost-effective pathway altogether. As THA and TKA are potentially costly procedures and the numbers are increasing in an economical limited environment, the aim of this study is to present baseline detailed economical calculations of fast-track THA and TKA and compare...

  10. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been...

  11. Fast-Track Cleanup at Closing DoD Installations

    Science.gov (United States)

    The Fast-Track Cleanup program strives to make parcels available for reuse as quickly as possible by the transfer of uncontaminated or remediated parcels, the lease of contaminated parcels where cleanup is underway, or the 'early transfer' of contaminated property undergoing cleanup.

  12. Patient-reported outcome after fast-track knee arthroplasty

    DEFF Research Database (Denmark)

    Larsen, Kristian; Hansen, Torben B; Søballe, Kjeld

    2012-01-01

    PURPOSE: The purpose of this study was to describe patient-related functional outcomes after fast-track total knee arthroplasty and unicompartmental knee arthroplasty. Furthermore, we wanted to assess physical areas where an additional need for rehabilitation could be identified, and finally, we...

  13. Design of a Hardware Track Finder (Fast Tracker) for the ATLAS Trigger

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00010976; Albicocco, P.; Alison, J.; Ancu, L.S.; Anderson, J.; Andari, N.; Andreani, A.; Andreazza, A.; Annovi, A.; Antonelli, M.; Asbah, N.; Atkinson, M.; Baines, J.; Barberio, E.; Beccherle, R.; Beretta, M.; Bertolucci, F.; Biesuz, N.V.; Blair, R.; Bogdan, M.; Boveia, A.; Britzger, D.; Bryant, P.; Burghgrave, B.; Calderini, G.; Camplani, A.; Cavasinni, V.; Chakraborty, D.; Chang, P.; Cheng, Y.; Citraro, S.; Citterio, M.; Crescioli, F.; Dawe, N.; Dell'Orso, M.; Donati, S.; Dondero, P.; Drake, G.; Gadomski, S.; Gatta, M.; Gentsos, C.; Giannetti, P.; Gkaitatzis, S.; Gramling, J.; Howarth, J.W.; Iizawa, T.; Ilic, N.; Jiang, Z.; Kaji, T.; Kasten, M.; Kawaguchi, Y.; Kim, Y.K.; Kimura, N.; Klimkovich, T.; Kolb, M.; Kordas, K.; Krizka, K.; Kubota, T.; Lanza, A.; Li, H.L.; Liberali, V.; Lisovyi, M.; Liu, L.; Love, J.; Luciano, P.; Luongo, C.; Magalotti, D.; Maznas, I.; Meroni, C.; Mitani, T.; Nasimi, H.; Negri, A.; Neroutsos, P.; Neubauer, M.; Nikolaidis, S.; Okumura, Y.; Pandini, C.; Petridou, C.; Piendibene, M.; Proudfoot, J.; Rados, P.; Roda, C.; Rossi, E.; Sakurai, Y.; Sampsonidis, D.; Saxon, J.; Schmitt, S.; Schoening, A.; Shochet, M.; Shojaii, S.; Soltveit, H.; Sotiropoulou, C.L.; Stabile, A.; Swiatlowski, M.; Tang, F.; Taylor, P.T.; Testa, M.; Tompkins, L.; Vercesi, V.; Volpi, G.; Wang, R.; Watari, R.; Webster, J.; Wu, X.; Yorita, K.; Yurkewicz, A.; Zeng, J.C.; Zhang, J.; Zou, R.

    2016-01-01

    The use of tracking information at the trigger level in the LHC Run II period is crucial for the trigger an data acquisition (TDAQ) system and will be even more so as contemporary collisions that occur at every bunch crossing will increase in Run III. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide every Level-1 accepted event (100 kHz) and within 100$\\mu$s, full tracking information for tracks with momentum as low as 1 GeV. Providing fast, extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondary vertices to ensure robust selections and improve the trigger performance.

  14. Convalescence after colonic resection with fast-track versus conventional care

    DEFF Research Database (Denmark)

    Hjort Jakobsen, D; Sonne, E; Basse, L

    2004-01-01

    BACKGROUND: Multi-modal rehabilitation programmes may improve early postoperative body composition, pulmonary function, exercise capacity, and reduce hospital stay. So far, no data are available on convalescence after discharge. AIM: The objectives were to compare convalescence data (fatigue, sleep...... vs. 8 days in the fast-track vs. conventional care group, respectively (p sleep were increased in the conventional care group when compared with the fast-track group (p ... results in earlier resumption of normal activities with reduced fatigue and need for sleep postoperatively compared to conventional care, and without increased need for nursing care or visits to general practitioners. However, readmissions may occur more frequently....

  15. Why still in hospital after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Lunn, Troels H; Troelsen, Anders

    2011-01-01

    Background and purpose Length of stay (LOS) following total hip and knee arthroplasty (THA and TKA) has been reduced to about 3 days in fast-track setups with functional discharge criteria. Earlier studies have identified patient characteristics predicting LOS, but little is known about specific...... reasons for being hospitalized following fast-track THA and TKA. Patients and methods To determine clinical and logistical factors that keep patients in hospital for the first postoperative 24-72 hours, we performed a cohort study of consecutive, unselected patients undergoing unilateral primary THA (n...

  16. An innovative strategy to increase a professional workforce: the fast track initiative for health visitors in England.

    Science.gov (United States)

    Sayer, Lynn; Barriball, K Louise; Bliss, Julie; Bakhshi, Savita; While, Alison E

    2016-04-01

    Fast tracking is one strategy that organizations use to ameliorate workforce shortfalls by attracting new recruits, and accelerating their skills development and experience. In response to the Government's target of rapidly expanding the number of health visitors in England's National Health Service, the fast track initiative was launched to recruit newly qualified (fast track) as well as experienced (standard entry) nurses and midwives onto health visiting programmes. This paper evaluates the fast track initiative, from the perspective of fast track and standard entry students, practice teachers and health visitor managers. A mixed methods design was used comprising a questionnaire survey (n = 71 students), semi-structured interviews (n = 37 students), telephone interviews (n = 13 managers) and six focus groups (n = 24 practice teachers). Data were collected between April 2012 and July 2013. Descriptive statistics, t-tests and the Pearson Chi-square test were used to analyse the quantitative data. The qualitative data were analysed thematically. Motivations for health visiting as a career choice were similar for fast track and standard entry students, with career progression and interest in health promotion being key motivators. There was consensus that personal qualities and characteristics were more important than experience or qualifications. However, fast track students were significantly less confident about their public health competencies in leadership and management (p communication (p  0.5). Fast tracking offers a useful recruitment strategy in order to expand the health visitor workforce, but longitudinal research is needed to confirm benefits such as retention and career trajectories. © The Author(s) 2015.

  17. Real time Faraday spectrometer

    Science.gov (United States)

    Smith, Jr., Tommy E.; Struve, Kenneth W.; Colella, Nicholas J.

    1991-01-01

    This invention uses a dipole magnet to bend the path of a charged particle beam. As the deflected particles exit the magnet, they are spatially dispersed in the bend-plane of the magnet according to their respective momenta and pass to a plurality of chambers having Faraday probes positioned therein. Both the current and energy distribution of the particles is then determined by the non-intersecting Faraday probes located along the chambers. The Faraday probes are magnetically isolated from each other by thin metal walls of the chambers, effectively providing real time current-versus-energy particle measurements.

  18. Real time Faraday spectrometer

    International Nuclear Information System (INIS)

    Smith, T.E.; Struve, K.W.; Colella, N.J.

    1991-01-01

    This patent describes an invention which uses a dipole magnet to bend the path of a charged particle beam. As the deflected particles exit the magnet, they are spatially dispersed in the bend-plane of the magnet according to their respective momenta and pass to a plurality of chambers having Faraday probes positioned therein. Both the current and energy distribution of the particles is then determined by the non-intersecting Faraday probes located along the chambers. The Faraday probes are magnetically isolated from each other by thin metal walls of the chambers, effectively providing real time current-versus-energy particle measurements

  19. Controlling type I error rate for fast track drug development programmes.

    Science.gov (United States)

    Shih, Weichung J; Ouyang, Peter; Quan, Hui; Lin, Yong; Michiels, Bart; Bijnens, Luc

    2003-03-15

    The U.S. Food and Drug Administration (FDA) Modernization Act of 1997 has a Section (No. 112) entitled 'Expediting Study and Approval of Fast Track Drugs' (the Act). In 1998, the FDA issued a 'Guidance for Industry: the Fast Track Drug Development Programs' (the FTDD programmes) to meet the requirement of the Act. The purpose of FTDD programmes is to 'facilitate the development and expedite the review of new drugs that are intended to treat serious or life-threatening conditions and that demonstrate the potential to address unmet medical needs'. Since then many health products have reached patients who suffered from AIDS, cancer, osteoporosis, and many other diseases, sooner by utilizing the Fast Track Act and the FTDD programmes. In the meantime several scientific issues have also surfaced when following the FTDD programmes. In this paper we will discuss the concept of two kinds of type I errors, namely, the 'conditional approval' and the 'final approval' type I errors, and propose statistical methods for controlling them in a new drug submission process. Copyright 2003 John Wiley & Sons, Ltd.

  20. Fast tracking in adult cardiac surgery at Pakistan Institute of Medical Sciences

    International Nuclear Information System (INIS)

    Ahmed, N.; Khan, F.; Zahoor, M.; Rafique, M.; Faisal, M.

    2010-01-01

    Background: Early extubation after cardiac operation is an important aspect of fast-track cardiac anaesthesia. The length of stay in ICU limits utilisation of operation theatre in cardiac surgery. Increasing cost, limited resources, and newer surgical strategies have stimulated effectiveness of all routines in cardiac surgery, anaesthesia, and intensive care. Aim of this study was to determine the feasibility of fast-tracking in adult cardiac surgery and its effects on post operative recovery in our setup. Methods: This descriptive study was conducted over 14 months between Jul 16, 2007 to Sep 16, 2008. All the open heart cases were included unless absolute contraindications were there. We applied the rapid recovery protocol adopted from Oslo Hospital Norway in an attempt to achieve fast-tracking in our setup. Results: Two-hundred-seventy-four consecutive cases out of 400 operated cases were included in this study. Mean age was 47.69 +- 15.11 years, 27.7% were females, 5.8% were emergency cases, 5.1% were COPD, 11.1% were atrial fibrillation, and 6.9% were NYHA class-III cases. CABG was done in 66.1% cases and mean CPB-time was 75.92 +- 16.20 min. Mean Ventilation-time was 4.47+-4.48 hrs., 86% patients were fast-tracked to be extubated within 6 hours, and 85.4% patients remained free of post-op complications. Six (2.2%) re-intubatIions, 2.6% arrhythmias, 6.6% pleural effusions and 2.2% consolidation were observed post-operatively. Mean ICU stay was 2.49 +- 0.95 days and in-hospital mortality was 2.2%. Conclusion: Fast-tracking with extubation within 6 hours is feasible approach which minimises the post-operative complications significantly in adult cardiac surgical patients. (author)

  1. A fast neutron detector with IP by track measurement

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Yang Jun; Zhang Qiang; Zhao Xiangfeng; Wang Daohua

    2004-01-01

    Imaging Plate(IP) is very sensitive to electric particles, especially to heavy ions. As we know, the recoiling protons are produced while fast neutrons scattered in light material containing hydrogen. When the recoiling proton enters in the sensitive layer of IP, a track will be recorded by IP. In this paper, a fast neutron detector based on IP and (n, p) reaction is described in detail, the detector's efficiency is studied also. (authors)

  2. Fast track trigger processor for the OPAL detector at LEP

    Energy Technology Data Exchange (ETDEWEB)

    Carter, A A; Carter, J R; Ward, D R; Heuer, R D; Jaroslawski, S; Wagner, A

    1986-09-20

    A fast hardware track trigger processor being built for the OPAL experiment is described. The processor will analyse data from the central drift chambers of OPAL to determine whether any tracks come from the interaction region, and thereby eliminate background events. The processor will find tracks over a large angular range, vertical strokecos thetavertical stroke < or approx. 0.95. The design of the processor is described, together with a brief account of its hardware implementation for OPAL. The results of feasibility studies are also presented.

  3. The ATLAS Fast Tracker Processing Units - track finding and fitting

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00384270; The ATLAS collaboration; Alison, John; Ancu, Lucian Stefan; Andreani, Alessandro; Annovi, Alberto; Beccherle, Roberto; Beretta, Matteo; Biesuz, Nicolo Vladi; Bogdan, Mircea Arghir; Bryant, Patrick; Calabro, Domenico; Citraro, Saverio; Crescioli, Francesco; Dell'Orso, Mauro; Donati, Simone; Gentsos, Christos; Giannetti, Paola; Gkaitatzis, Stamatios; Gramling, Johanna; Greco, Virginia; Horyn, Lesya Anna; Iovene, Alessandro; Kalaitzidis, Panagiotis; Kim, Young-Kee; Kimura, Naoki; Kordas, Kostantinos; Kubota, Takashi; Lanza, Agostino; Liberali, Valentino; Luciano, Pierluigi; Magnin, Betty; Sakellariou, Andreas; Sampsonidis, Dimitrios; Saxon, James; Shojaii, Seyed Ruhollah; Sotiropoulou, Calliope Louisa; Stabile, Alberto; Swiatlowski, Maximilian; Volpi, Guido; Zou, Rui; Shochet, Mel

    2016-01-01

    The Fast Tracker is a hardware upgrade to the ATLAS trigger and data-acquisition system, with the goal of providing global track reconstruction by the start of the High Level Trigger starts. The Fast Tracker can process incoming data from the whole inner detector at full first level trigger rate, up to 100 kHz, using custom electronic boards. At the core of the system is a Processing Unit installed in a VMEbus crate, formed by two sets of boards: the Associative Memory Board and a powerful rear transition module called the Auxiliary card, while the second set is the Second Stage board. The associative memories perform the pattern matching looking for correlations within the incoming data, compatible with track candidates at coarse resolution. The pattern matching task is performed using custom application specific integrated circuits, called associative memory chips. The auxiliary card prepares the input and reject bad track candidates obtained from from the Associative Memory Board using the full precision a...

  4. Faraday imaging at high temperatures

    Science.gov (United States)

    Hackel, Lloyd A.; Reichert, Patrick

    1997-01-01

    A Faraday filter rejects background light from self-luminous thermal objects, but transmits laser light at the passband wavelength, thus providing an ultra-narrow optical bandpass filter. The filter preserves images so a camera looking through a Faraday filter at a hot target illuminated by a laser will not see the thermal radiation but will see the laser radiation. Faraday filters are useful for monitoring or inspecting the uranium separator chamber in an atomic vapor laser isotope separation process. Other uses include viewing welds, furnaces, plasma jets, combustion chambers, and other high temperature objects. These filters are can be produced at many discrete wavelengths. A Faraday filter consists of a pair of crossed polarizers on either side of a heated vapor cell mounted inside a solenoid.

  5. A fast fiducial marker tracking model for fully automatic alignment in electron tomography

    KAUST Repository

    Han, Renmin; Zhang, Fa; Gao, Xin

    2017-01-01

    Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner.In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers.The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the

  6. A fast fiducial marker tracking model for fully automatic alignment in electron tomography

    KAUST Repository

    Han, Renmin

    2017-10-20

    Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner.In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers.The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the

  7. Implementation of the scientific evidence into daily practice - example from fast-track colonic cancer surgery

    DEFF Research Database (Denmark)

    Hammer, J.; Harling, H.; Wille-Jorgensen, P.

    2008-01-01

    Objective To report the implementation and results of fast-track surgery for colonic cancer in the daily routine. Method A total of 131 consecutive patients scheduled for elective colonic cancer resections entered a fast-track perioperative course after thorough information. The regimen contained...

  8. Active Faraday optical frequency standard.

    Science.gov (United States)

    Zhuang, Wei; Chen, Jingbiao

    2014-11-01

    We propose the mechanism of an active Faraday optical clock, and experimentally demonstrate an active Faraday optical frequency standard based on narrow bandwidth Faraday atomic filter by the method of velocity-selective optical pumping of cesium vapor. The center frequency of the active Faraday optical frequency standard is determined by the cesium 6 (2)S(1/2) F=4 to 6 (2)P(3/2) F'=4 and 5 crossover transition line. The optical heterodyne beat between two similar independent setups shows that the frequency linewidth reaches 281(23) Hz, which is 1.9×10(4) times smaller than the natural linewidth of the cesium 852-nm transition line. The maximum emitted light power reaches 75 μW. The active Faraday optical frequency standard reported here has advantages of narrow linewidth and reduced cavity pulling, which can readily be extended to other atomic transition lines of alkali and alkaline-earth metal atoms trapped in optical lattices at magic wavelengths, making it useful for new generation of optical atomic clocks.

  9. Faraday effect in semimagnetic semiconductors

    International Nuclear Information System (INIS)

    Nikitin, P.I.; Savchuk, A.I.

    1990-01-01

    Experimental and theoretical studies of the Faraday effect in a new class of materials -semimagnetic semiconductors (SS) have been received. Mechanisms of the giant Faraday effect in SS based on s, p-d exchange interaction of excitons, electrons and holes with magnetic ions have been discussed. Faraday rotation as a function of a radiation wavelength, magnetic component concentration, temperature, magnetic field intensity for crystals A 2 B 6 (Mn)A 2 x -1Mn xB 6 : and other SS (GaAs(Mn), CdP 2 (Mn),Pb 1-X2 )Mn x J 2 have been considered. We have attended to use FR for the study of a paramagnetic-spin glass transmission for determining the role of the relaxation effects with a participation of magnetic Mn 2+ ions, exitons, polarons in the direct and inverse Faraday effects. In addition the features of FR in thin films of SS and in spin superlattices have been discussed. Finally, we have analysed possibilities of applying the SS Faraday effect for developing magnetooptic devices (optical isolators and fibre optic sensors of magnetic fields)

  10. ATLAS Fast Tracker Status and Tracking at High luminosity LHC

    CERN Document Server

    Ilic, Nikolina; The ATLAS collaboration

    2018-01-01

    The LHC’s increase in centre of mass energy and luminosity in 2015 makes controlling trigger rates with high efficiency challenging. The ATLAS Fast TracKer (FTK) is a hardware processor built to reconstruct tracks at a rate of up to 100 kHz and provide them to the high level trigger. The FTK reconstructs tracks by matching incoming detector hits with pre-defined track patterns stored in associative memory on custom ASICs. Inner detector hits are fit to these track patterns using modern FPGAs. This talk describes the electronics system used for the FTK’s massive parallelization. The installation, commissioning and running of the system is happening in 2016, and is detailed in this talk. Tracking at High luminosity LHC is also presented.

  11. Optimization of a Short Faraday Cup for Low-Energy Ions using Numerical Simulations

    CERN Document Server

    Bravin, E; Garcia Sosa, A; Welsch, CP

    2014-01-01

    ISOLDE, the heavy-ion facility at CERN is undergoing a major upgrade with the installation of a superconducting LINAC that will allow post-acceleration of ion beams up to 10 MeV/u. In this framework, customized beam diagnostics are being developed in order to fulfill the design requirements as well as to fit in the compact diagnostic boxes foreseen. The main detector of this system is a compact Faraday cup that will measure beam intensities in the range of 1 pA to 1 nA. In this contribution, simulation results of electrostatic fields and particle tracking are detailed for different Faraday cup prototypes taking into account the energy spectrum and angle of emission of the ion-induced secondary electrons.

  12. SPARSE FARADAY ROTATION MEASURE SYNTHESIS

    International Nuclear Information System (INIS)

    Andrecut, M.; Stil, J. M.; Taylor, A. R.

    2012-01-01

    Faraday rotation measure synthesis is a method for analyzing multichannel polarized radio emissions, and it has emerged as an important tool in the study of Galactic and extragalactic magnetic fields. The method requires the recovery of the Faraday dispersion function from measurements restricted to limited wavelength ranges, which is an ill-conditioned deconvolution problem. Here, we discuss a recovery method that assumes a sparse approximation of the Faraday dispersion function in an overcomplete dictionary of functions. We discuss the general case when both thin and thick components are included in the model, and we present the implementation of a greedy deconvolution algorithm. We illustrate the method with several numerical simulations that emphasize the effect of the covered range and sampling resolution in the Faraday depth space, and the effect of noise on the observed data.

  13. Faraday imaging at high temperatures

    International Nuclear Information System (INIS)

    Hackel, L.A.; Reichert, P.

    1997-01-01

    A Faraday filter rejects background light from self-luminous thermal objects, but transmits laser light at the passband wavelength, thus providing an ultra-narrow optical bandpass filter. The filter preserves images so a camera looking through a Faraday filter at a hot target illuminated by a laser will not see the thermal radiation but will see the laser radiation. Faraday filters are useful for monitoring or inspecting the uranium separator chamber in an atomic vapor laser isotope separation process. Other uses include viewing welds, furnaces, plasma jets, combustion chambers, and other high temperature objects. These filters are can be produced at many discrete wavelengths. A Faraday filter consists of a pair of crossed polarizers on either side of a heated vapor cell mounted inside a solenoid. 3 figs

  14. L0 Confirmation with fast, Tsa based tracking in the T-stations

    CERN Document Server

    Albrecht, J; Terrier, H

    2007-01-01

    A fast tracking algorithm to confirm the high $p_T$ L0 trigger objects with tracks from the T-stations is presented. The L0 trigger candidate is used to define a search window to a potential track. Using this, a seeded track search is performed. The track finding algorithm is based on the \\textit{TsaSeeding} algorithm~\\cite{bib:Tsa}. The efficiency to confirm a true L0 trigger signal is around 96\\%, the momentum can be measured up to $\\Delta p/p$=3\\%.

  15. Low manipulation prevalence following fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C.; Gromov, Kirill

    2015-01-01

    BACKGROUND AND PURPOSE: Postoperative joint stiffness following total knee arthroplasty (TKA) may compromise the outcome and necessitate manipulation. Previous studies have not been in a fast-track setting with optimized pain treatment, early mobilization, and short length of stay (LOS), which ma...

  16. After colonic surgery: The lived experience of participating in a fast-track programme

    DEFF Research Database (Denmark)

    Norlyk, Annelise; Harder, Ingegerd

    2009-01-01

    Postoperative recovery can be accelerated and hospitalization reduced through fast-track programmes. However, documented knowledge is limited and primarily focusing on a medical perspective whereas the patients' perspective lacks documentation. This study describes the lived experience of partici......Postoperative recovery can be accelerated and hospitalization reduced through fast-track programmes. However, documented knowledge is limited and primarily focusing on a medical perspective whereas the patients' perspective lacks documentation. This study describes the lived experience...

  17. Faraday effect and solar neutrino problem

    International Nuclear Information System (INIS)

    Nawaz, S.

    2001-01-01

    We have studied the Faraday effect and solar neutrino problem. Our main emphasis was on the Faraday rotation of neutrino de Broglie wave of electron-neutrino producing in the nuclear reactions in the sun and converting into any other flavor of neutrino while passing through matter and/or magnetic field of the sun. We have shown that specific Faraday angle can minimize the number of free parameters occurring in the neutrino oscillation. We have also shown that the resonant Faraday angle corresponding to the resonance of MSW effect can be obtained the knowledge of the oscillation parameter delta m/sup 2/ and the neutrino energy. Using neutrino-Faraday angle approach, we have shown that the matter enhanced neutrino oscillations is dominating over the resonant spin flavor precession (RSFP) even in the favorable region of the spin flavor procession. Using the latest solar neutrino data, we have shown that Faraday angle is almost 10/sup -3/ times smaller. This can be interpreted as the interaction of magnetic moment of neutrino with the solar magnetic field is negligibly small as compare to the effect of matter field on the neutrino oscillation. (author)

  18. Faraday anomalous dispersion optical tuners

    Science.gov (United States)

    Wanninger, P.; Valdez, E. C.; Shay, T. M.

    1992-01-01

    Common methods for frequency stabilizing diode lasers systems employ gratings, etalons, optical electric double feedback, atomic resonance, and a Faraday cell with low magnetic field. Our method, the Faraday Anomalous Dispersion Optical Transmitter (FADOT) laser locking, is much simpler than other schemes. The FADOT uses commercial laser diodes with no antireflection coatings, an atomic Faraday cell with a single polarizer, and an output coupler to form a compound cavity. This method is vibration insensitive, thermal expansion effects are minimal, and the system has a frequency pull in range of 443.2 GHz (9A). Our technique is based on the Faraday anomalous dispersion optical filter. This method has potential applications in optical communication, remote sensing, and pumping laser excited optical filters. We present the first theoretical model for the FADOT and compare the calculations to our experimental results.

  19. Neutrino oscillations and a new Faraday effect

    International Nuclear Information System (INIS)

    Anwar Mughal, M.; Ahmed, K.

    1992-07-01

    By analogy with the classical Faraday effect for the electromagnetic waves, a Faraday effect for massive neutrinos is found to be a somewhat generic description of neutrino oscillations when the neutrinos traverse a dense medium with or without a magnetic field. We further plot the Faraday angle for the solar neutrino problem as an illustration of the fact that the Faraday effect may yield a conceptually convenient parametrization of various neutrino oscillation scenarios. (author). 8 refs, 3 figs

  20. Gyromagnetic Faraday effect in transparent magnetic crystals

    International Nuclear Information System (INIS)

    Krinchik, G.S.; Koptsik, S.V.; Gan'shina, E.A.

    1982-01-01

    Faraday effect in the transparent paramagnetic Gd 3 Ga 5 O 12 at 4.2 K in magnetic fields up to 50 kE within 1-2.5 μm range is studied. The gyromagnetic Faraday effect caused by precession of magnetization vector under the effect of the magnetic field of wave light is shown to be the determinimg one in the infrared range. Hyromagnetic and gyroelectric contributions to Faraday effect in Gd 3 Fe 5 O 12 and Y 3 Fe 5 O 12 are determined. It is shown that field dependence of Faraday effect in non-colinear ferrimagnetic Yb 3 Fe 5 O 12 qualitatively proves the existence of gyromagnetic Faraday effect

  1. A modified fast-track program for pancreatic surgery: a prospective single-center experience.

    Science.gov (United States)

    di Sebastiano, Pierluigi; Festa, Leonardina; De Bonis, Antonio; Ciuffreda, Andrea; Valvano, Maria Rosa; Andriulli, Angelo; di Mola, F Francesco

    2011-03-01

    The objective of this study is to evaluate the impact of a fast-track protocol in a high-volume center for patients with pancreatic disorders. The concept of fast-track surgery allowing accelerated postoperative recovery is accepted in colorectal surgery, but efficacy data are only preliminary for patients undergoing major pancreatic surgery. We aimed to evaluate the impact of a modified fast-track protocol in a high-volume center for patients with pancreatic disorders. Between February 2005 and January 2010, 145 subjects had resective pancreatic surgery and were enrolled in the program. Essential features of the program were no preanaesthetic medication, upper and lower air-warming device, avoidance of excessive i.v. fluids perioperatively, effective control of pain, early reinstitution of oral feeding, and immediate mobilization and restoration of bowel function following surgery. Outcome measures were postoperative complications such as pancreatic fistula, delayed gastric emptying, biliary leak, intra-abdominal abscess, post-pancreatectomy hemorrhage, acute pancreatitis, wound infection, 30-day mortality, postoperative hospital stay, and readmission rates. On average, patients were discharged on postoperative day 10 (range 6-69), with a 30-day readmission rate of 6.2%. Percentage of patients with at least one complication was 38.6%. Pancreatic anastomotic leakage occurred in seven of 101 pancreatico-jejunostomies, and biliary leak in three of 109 biliary jejunostomies. Postoperative hemorrhage occurred in ten (6.9%) patients and wound infection in nine (6.2%) cases. In-hospital mortality was 2.7%. Fast-track parameters, such as normal food and first stool, correlated significantly with early discharge (jaundice, and resumption of normal diet by the 5th postoperative day were independent factors of early discharge. Fast-track programs are feasible, easy, and also applicable for patients undergoing a major surgery such as pancreatic resection.

  2. Environmental Impact Assessment of Kathmandu Terai Fast-Track

    Directory of Open Access Journals (Sweden)

    Padam Kanta Dahal

    2014-12-01

    Full Text Available  Road transport is dominant necessity for the overall economic development of any nation. In case of Nepal, an easy access between the Capital City and Terai, the store-house of the country and is very necessary. To facilitate this promotion of an improved core road network, Government of Nepal has launched the Kathmandu Terai Fast Track Project. Many concerned personalities and sectors had considered this project to be number one in the list of seventeen projects of national pride declared by the government. The main objective of this study was to identify the impacts of proposed project implementation on physical, biological, socio-economic and cultural environment of the project area and propose mitigation measures to avoid or mitigate such impacts. Primary information collection and secondary data review was the source of data with cross sectional descriptive study design. Data was taken purposively in the project affected area. Length of 72.6 km fast track from Kathmandu – Lalitpur – Makawanpur and up to Nijgadh in Bara district to link with the East West Highway will be of four lanes with 50 m on each side. The project was proposed to have 96 bridges big or small; 1.6 km long tunnel will be built in Thingan of Makawanpur on public-private partnership. It had projected costs of more than NRs 250 million. The impacts on land use will be on about 30km of agricultural land, 43km of forests and about 3km of other land uses, bridges etc. in the main alignment. The impacts on human life will mainly be in villages near the alignment. There are 38 villages within about 50m of the main alignment. The project can be continued with minimum of environmental degradation by applying the mitigation measures. Nation has been investing a lot of resources. Upon the completion of the fast track, the distance and time to reach the capital city from Terai will come down to only 1.5 hours and will transform the capital, eastern Terai and the country as a

  3. Orthostatic intolerance during early mobilization after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, O; Bundgaard-Nielsen, M; Solgaard, S

    2012-01-01

    has not been established after THA. This study evaluated the cardiovascular response and tissue oxygenation to mobilization before and after surgery in relation to OI in fast-track THA patients. METHODS: /st>OI and the cardiovascular response to standing were evaluated with a standardized mobilization......BACKGROUND: /st>Early postoperative mobilization is a cornerstone in fast-track total hip arthroplasty (THA), but postoperative orthostatic intolerance (OI) may delay early recovery or lead to fainting, falls, and prosthesis dislocation or fracture. However, the prevalence and pathophysiology of OI...... protocol, before, 6, and 24 h after surgery in 26 patients undergoing THA with spinal anaesthesia and an opioid-sparing analgesic regime. Haemoglobin, fluid balance, and opioid use were recorded. Systolic (SAP) and diastolic (DAP) arterial pressure, heart rate (HR), stroke volume (SV), cardiac output (CO...

  4. Rapid determination of Faraday rotation in optical glasses by means of secondary Faraday modulator.

    Science.gov (United States)

    Sofronie, M; Elisa, M; Sava, B A; Boroica, L; Valeanu, M; Kuncser, V

    2015-05-01

    A rapid high sensitive method for determining the Faraday rotation of optical glasses is proposed. Starting from an experimental setup based on a Faraday rod coupled to a lock-in amplifier in the detection chain, two methodologies were developed for providing reliable results on samples presenting low and large Faraday rotations. The proposed methodologies were critically discussed and compared, via results obtained in transmission geometry, on a new series of aluminophosphate glasses with or without rare-earth doping ions. An example on how the method can be used for a rapid examination of the optical homogeneity of the sample with respect to magneto-optical effects is also provided.

  5. Fast pattern recognition with the ATLAS L1Track trigger for HL-LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00530554; The ATLAS collaboration

    2017-01-01

    A fast hardware based track trigger is being developed in ATLAS for the High Luminosity upgrade of the Large Hadron Collider. The goal is to achieve trigger levels in the high pile-up conditions of the High Luminosity Large Hadron Collider that are similar or better than those achieved at low pile-up conditions by adding tracking information to the ATLAS hardware trigger. A method for fast pattern recognition using the Hough transform is investigated. In this method, detector hits are mapped onto a 2D parameter space with one parameter related to the transverse momentum and one to the initial track direction. The performance of the Hough transform is studied at different pile-up values. It is also compared, using full event simulation of events with average pile-up of 200, with a method based on matching detector hits to pattern banks of simulated tracks stored in a custom made Associative Memory ASICs. The pattern recognition is followed by a track fitting step which calculates the track parameters. The spee...

  6. Hardware-based tracking at trigger level for ATLAS: The Fast Tracker (FTK) Project

    CERN Document Server

    Gramling, Johanna; The ATLAS collaboration

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer (FTK) is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level 1 trigger (at a maximum rate of 100 kHz) the FTK receives data from the 80 million channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware-based track reconstruction, using associative memory (AM) that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. Narrow roads permit a fast track fitting but need many patterns stored in the AM to ensure ...

  7. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    INTRODUCTION: Most institutions perform percutaneous liver biopsy with a post-biopsy patient observation period lasting up to eight hours, which is resource-demanding. This study aimed to evaluate the safety of liver biopsy performed in a fast-track set-up with an only one-hour post......-biopsy observation time. METHODS: Patients referred to our institution underwent fast-track ultrasound-guided 18-gauge Tru-Cut liver biopsy procedures. Each single biopsy procedure was followed by a post-procedure observational period of one hour and an additional focused assessment with sonography for trauma before...... safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  8. Fast pattern recognition with the ATLAS L1 track trigger for the HL-LHC

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2016-01-01

    A fast hardware based track trigger for high luminosity upgrade of the Large Hadron Collider (HL- LHC) is being developed in ATLAS. The goal is to achieve trigger levels in high pileup collisions that are similar or even better than those achieved at low pile-up running of LHC by adding tracking information to the ATLAS hardware trigger which is currently based on information from calorimeters and muon trigger chambers only. Two methods for fast pattern recognition are investigated. The first is based on matching tracker hits to pattern banks of simulated high momentum tracks which are stored in a custom made Associative Memory (AM) ASIC. The second is based on the Hough transform where detector hits are transformed into 2D Hough space with one variable related to track pt and one to track direction. Hits found by pattern recognition will be sent to a track fitting step which calculates the track parameters . The speed and precision of the track fitting depends on the quality of the hits selected by the patte...

  9. Comparison of fast neutron-induced tracks in plastics using the electrochemical etching method

    International Nuclear Information System (INIS)

    Cotter, S.J.; Gammage, R.B.; Thorngate, J.H.; Ziemer, P.L.

    1979-01-01

    Four plastics were examined by the electrochemical etching method for their suitability in registering fast neutron-induced recoil particle tracks. The plastics were cellulose acetate, cellulose triacetate, cellulose acetobutyrate and polycarbonate. Cellulose acetate and triacetate displayed high levels of water absorptivity during etching while the acetobutyrate foils cracked due to electromechanical stresses at high frequencies (>500 Hz). The clarity of the etched track was superior in the polycarbonate foils, suggesting the latter as the generally preferred dosimeter for fast neutrons. (author)

  10. A fast track trigger processor for the OPAL detector at LEP

    International Nuclear Information System (INIS)

    Carter, A.A.; Jaroslawski, S.; Wagner, A.

    1986-01-01

    A fast hardware track trigger processor being built for the OPAL experiment is described. The processor will analyse data from the central drift chambers of OPAL to determine whether any tracks come from the interaction region, and thereby eliminate background events. The processor will find tracks over a large angular range, vertical strokecos thetavertical stroke < or approx. 0.95. The design of the processor is described, together with a brief account of its hardware implementation for OPAL. The results of feasibility studies are also presented. (orig.)

  11. Fast simulation of the forward tracking detector of HPLUS

    International Nuclear Information System (INIS)

    Zhang Yapeng; Fan Ruirui; Fu Fen; Yue Ke; Yuan Xiaohua; Xu Huagen; Chinese Academy of Sciences, Beijing; Yao Nan; Xu Hushan; Jin Genming; Liang Jinjie; Chen Ruofu; Sun Zhiyu; Duan Limin; Xiao Zhigang; Tsinghua Univ., Beijing

    2008-01-01

    The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics Lanzhou Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp→pp+φ(→K + K - ), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed φ are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp→pp+K + K - as background. The geometry coverage of FTD for qb events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS. (authors)

  12. Fast neural-net based fake track rejection in the LHCb reconstruction

    CERN Document Server

    De Cian, Michel; Seyfert, Paul; Stahl, Sascha

    2017-01-01

    A neural-network based algorithm to identify fake tracks in the LHCb pattern recognition is presented. This algorithm, called ghost probability, retains more than 99 % of well reconstructed tracks while reducing the number of fake tracks by 60 %. It is fast enough to fit into the CPU time budget of the software trigger farm and thus reduces the combinatorics of the decay reconstructions, as well as the number of tracks that need to be processed by the particle identification algorithms. As a result, it strongly contributes to the achievement of having the same reconstruction online and offline in the LHCb experiment in Run II of the LHC.

  13. Delirium in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Kurbegovic, Sorel; Andersen, Jens; Krenk, Lene

    2015-01-01

    BACKGROUND: Postoperative delirium (PD) is a common but serious problem after major surgery with a multifactorial pathogenesis including age, pain, opioid use, sleep disturbances and the surgical stress response. These factors have been minimised by the "fast-track methodology" previously...... demonstrated to enhance recovery and reduce morbidity. METHODS: Clinical symptoms of PD were routinely collected three times daily from preoperatively until discharge in a well-defined enhanced recovery program after colonic surgery in 247 consecutive patients. RESULTS: Total median length of hospital stay...... postoperative recovery program may decrease the risk and duration of PD after colonic surgery....

  14. The yield of colorectal cancer among fast track patients with normocytic and microcytic anaemia.

    Science.gov (United States)

    Panagiotopoulou, I G; Fitzrol, D; Parker, R A; Kuzhively, J; Luscombe, N; Wells, A D; Menon, M; Bajwa, F M; Watson, M A

    2014-05-01

    We receive fast track referrals on the basis of iron deficiency anaemia (IDA) for patients with normocytic anaemia or for patients with no iron studies. This study examined the yield of colorectal cancer (CRC) among fast track patients to ascertain whether awaiting confirmation of IDA is necessary prior to performing bowel investigations. A review was undertaken of 321 and 930 consecutive fast track referrals from Centre A and Centre B respectively. Contingency tables were analysed using Fisher's exact test. Logistic regression analyses were performed to investigate significant predictors of CRC. Overall, 229 patients were included from Centre A and 689 from Centre B. The odds ratio for microcytic anaemia versus normocytic anaemia in the outcome of CRC was 1.3 (95% confidence interval [CI]: 0.5-3.9) for Centre A and 1.6 (95% CI: 0.8-3.3) for Centre B. In a logistic regression analysis (Centre B only), no significant difference in CRC rates was seen between microcytic and normocytic anaemia (adjusted odds ratio: 1.9, 95% CI: 0.9-3.9). There was no statistically significant difference in the yield of CRC between microcytic and normocytic anaemia (p=0.515, Fisher's exact test) in patients with anaemia only and no colorectal symptoms. Finally, CRC cases were seen in both microcytic and normocytic groups with or without low ferritin. There is no significant difference in the yield of CRC between fast track patients with microcytic and normocytic anaemia. This study provides insufficient evidence to support awaiting confirmation of IDA in fast track patients with normocytic anaemia prior to requesting bowel investigations.

  15. The ATLAS Fast Tracker and Tracking at the High-Luminosity LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00236423; The ATLAS collaboration

    2016-01-01

    The LHC’s increase in centre of mass energy and luminosity in 2015 makes controlling trigger rates with high efficiency challenging. The ATLAS Fast TracKer (FTK) is a hardware processor built to reconstruct tracks at a rate of up to 100 kHz and provide them to the high level trigger. The FTK reconstructs tracks by matching incoming detector hits with pre-defined track patterns stored in associative memory on custom ASICs. Inner detector hits are fit to these track patterns using modern FPGAs. These procedings describe the electronics system used for the FTK’s massive parallelization. An overview of the installation, commissioning and running of the system is given. The ATLAS upgrades planned to enable tracking at the High Luminosity LHC are also discussed.

  16. Optical frequency comb Faraday rotation spectroscopy

    Science.gov (United States)

    Johansson, Alexandra C.; Westberg, Jonas; Wysocki, Gerard; Foltynowicz, Aleksandra

    2018-05-01

    We demonstrate optical frequency comb Faraday rotation spectroscopy (OFC-FRS) for broadband interference-free detection of paramagnetic species. The system is based on a femtosecond doubly resonant optical parametric oscillator and a fast-scanning Fourier transform spectrometer (FTS). The sample is placed in a DC magnetic field parallel to the light propagation. Efficient background suppression is implemented via switching the direction of the field on consecutive FTS scans and subtracting the consecutive spectra, which enables long-term averaging. In this first demonstration, we measure the entire Q- and R-branches of the fundamental band of nitric oxide in the 5.2-5.4 µm range and achieve good agreement with a theoretical model.

  17. Michael Faraday, media man.

    Science.gov (United States)

    Fara, Patricia

    2006-03-01

    Michael Faraday was an enthusiastic portrait collector, and he welcomed the invention of photography not only as a possible means of recording observations accurately, but also as a method for advertising science and its practitioners. This article (which is part of the Science in the Industrial Revolution series) shows that like many eminent scientists, Faraday took advantage of the burgeoning Victorian media industry by posing in various roles.

  18. Innovative technologies for Faraday shield cooling

    International Nuclear Information System (INIS)

    Rosenfeld, J.H.; Lindemuth, J.E.; North, M.T.; Goulding, R.H.

    1995-01-01

    Alternative advanced technologies are being evaluated for use in cooling the Faraday shields used for protection of ion cyclotron range of frequencies (ICR) antennae in Tokamaks. Two approaches currently under evaluation include heat pipe cooling and gas cooling. A Monel/water heat pipe cooled Faraday shield has been successfully demonstrated. Heat pipe cooling offers the advantage of reducing the amount of water discharged into the Tokamak in the event of a tube weld failure. The device was recently tested on an antenna at Oak Ridge National Laboratory. The heat pipe design uses inclined water heat pipes with warm water condensers located outside of the plasma chamber. This approach can passively remove absorbed heat fluxes in excess of 200 W/cm 2 ;. Helium-cooled Faraday shields are also being evaluated. This approach offers the advantage of no liquid discharge into the Tokamak in the event of a tube failure. Innovative internal cooling structures based on porous metal cooling are being used to develop a helium-cooled Faraday shield structure. This approach can dissipate the high heat fluxes typical of Faraday shield applications while minimizing the required helium blower power. Preliminary analysis shows that nominal helium flow and pressure drop can sufficiently cool a Faraday shield in typical applications. Plans are in progress to fabricate and test prototype hardware based on this approach

  19. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    Directory of Open Access Journals (Sweden)

    Stefan K. Burgdorf

    2012-01-01

    Full Text Available Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks during the shorter hospital stay. Specific data on nursing requirements after laparoscopic surgery are lacking. The purpose of the study was to evaluate the effect of operative technique (open versus laparoscopic operation, but without changing nurse staffing or principles for peri- or postoperative care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic repair, which was solely dependent on the presence of two specific surgeons at the same time. Thus, the patients were not selected for laparoscopic repair based on patient-related factors, but only on the simultaneous presence of two specific surgeons on the day of the operation. Results. Of a total of 540 included patients, 213 (39% were operated by a laparoscopic approach. The median hospital stay for patients with a primary anastomosis was significantly shorter after laparoscopic than after conventional open surgery (5 versus 8 days, while there was no difference in patients receiving a stoma (10 versus 10 days, ns, with no changes in the perioperative care regimens. Furthermore there were significant lower blood loss (50 versus 200 mL, and lower complication rate (21% versus 32%, in the laparoscopic group. Conclusion. Implementing laparoscopic colorectal surgery in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we

  20. Heating profiles on ICRF antenna Faraday shields

    International Nuclear Information System (INIS)

    Taylor, D.J.; Baity, F.W.; Hahs, C.L. Riemer, B.W.; Ryan, D.M.; Williamson, D.E.

    1992-01-01

    Poor definition of the heating profiles that occur during normal operation of Faraday shields for ion cyclotron resonant frequency (ICRF) antennas has complicated the mechanical design of ICRF system components. This paper reports that at Oak Ridge National Laboratory (ORNL), Faraday shield analysis is being used in defining rf heating profiles. In recent numerical analyses of proposed hardware for the Burning Plasma Experiment (BPX) and DIII-D, rf magnetic fields at Faraday shield surfaces were calculated, providing realistic predictions of the induced skin currents flowing on the shield elements and the resulting dissipated power profile. Detailed measurements on mock-ups of the Faraday shields for DIII-D and the Tokamak Fusion Test Reactor (TFTR) confirmed the predicted magnetic field distributions. A conceptual design for an uncooled Faraday shield for the BPX ion cyclotron resonance heating (ICRH) antenna, which should withstand the proposed long-pulse operation, has been completed. The analytical effort is described in detail, with emphasis on the design work for the BPX ICRH antenna conceptual design and for the replacement Faraday shield for the DIII-D FWCD antenna. Results of analyses are shown, and configuration issues involved in component modeling are discussed

  1. [Laparoscopic "fast-track" sigmoidectomy for diverticulitis disease in Germany. Results of a prospective quality assurance program].

    Science.gov (United States)

    Tsilimparis, N; Haase, O; Wendling, P; Kipfmüller, K; Schmid, M; Engemann, R; Schwenk, W

    2010-09-01

    The natural course of sigmoid colon diverticulitis during conservative therapy and the assessment of the perioperative morbidity after sigmoid colon resection are differently evaluated by surgeons and gastroenterologists. The "fast-track" rehabilitation accelerates the reconvalescence and reduces the rate of postoperative general complications after colorectal surgery. The results of the laparoscopic "Fast-track" sigmoidectomy should be examined within a quality assurance program to better evaluate the perioperative risks following surgical management of diverticulitis. A prospective data collection within the voluntary quality assurance program "fast-track" Kolon II was performed. All participating clinics agreed on a multimodal, evidence-based standard perioperative treatment in terms of a "fast-track" rehabilitation for elective operations for sigmoid diverticulitis. Data from 846 patients undergoing laparoscopic "fast-track" sigmoid colon resection in 23 surgical departments in Germany were collected and evaluated. The mean age of the patients was 63 years (range 23 - 91). 203 patients (24 %) had severe co-morbidities (ASA classification III - IV). A conversion to conventional open surgery was necessary in 51 cases (6 %). Complications occurred in 93 patients (11 %). 76 patients suffered a surgical complication (8.9 %) and 32 patients (3.8 %) a general complication. Two patients died postoperatively due to multi-organ failure following anastomotic leaks. The patients took solid food in median on day 1 after surgery (range, 0 - 5) and passed stool on day 2 (range, 0 - 22). Predefined discharge criteria (free of pain on oral medication, normal oral feeding, stool) were met on day 4 (range, 1 - 58) and the patients were discharged on day 7 (range, 3 - 72). The 30-day re-admission rate was 3.9 %. Patients undergoing laparoscopic "fast-track" sigmoidectomy had a low rate of general complications and had a rapid reconvalescence with a short postoperative in

  2. Laparoscopic surgery contributes more to nutritional and immunologic recovery than fast-track care in colorectal cancer.

    Science.gov (United States)

    Xu, Dong; Li, Jun; Song, Yongmao; Zhou, Jiaojiao; Sun, Fangfang; Wang, Jianwei; Duan, Yin; Hu, Yeting; Liu, Yue; Wang, Xiaochen; Sun, Lifeng; Wu, Linshan; Ding, Kefeng

    2015-02-04

    Many clinical trials had repeatedly shown that fast-track perioperative care and laparoscopic surgery are both preferred in the treatment of colorectal cancer. But few studies were designed to explore the diverse biochemical impacts of the two counterparts on human immunologic and nutritional status. Ninety-two cases of colorectal cancer patients meeting the inclusion criteria were randomized to four groups: laparoscopy with fast-track treatment (LAFT); open surgery with fast-track treatment (OSFT); laparoscopy with conventional treatment (LAC); open surgery with conventional treatment (OSC). Peripheral blood tests including nutritional factors (albumin, prealbumin, and transferrin), humoral immunologic factors (IgG, IgM, and IgA), and cellular immunologic factors (T and NK cells) were evaluated. Blood samples were collected preoperatively (baseline) and 12 and 96 h after surgery (indicated as POH12 and POH96, respectively). Albumin, transferrin, prealbumin, and IgG levels were the highest in the LAFT group for both POH12 and POH96 time intervals. Repeated measures (two-way ANOVA) indicated that the difference of albumin, transferrin, and IgG level were attributed to surgery type (P  0.05). Only in the laparoscopy-included groups, the relative albumin and IgG levels of POH96 were obviously higher than that of POH12. Laparoscopic surgery accelerated postoperative nutrition and immune levels rising again while fast-track treatment retarded the drop of postoperative nutrition and immune levels. Laparoscopic surgery might play a more important role than fast-track treatment in the earlier postoperative recovery of nutritional and immunologic status. Combined laparoscopic surgery with fast-track treatment provided best postoperative recovery of nutrition and immune status. These results should be further compared with the clinical outcomes of our FTMDT trial (clinicaltrials.gov: NCT01080547).

  3. Fast Track Open Partial Nephrectomy: Reduced Postoperative Length of Stay with a Goal-Directed Pathway Does Not Compromise Outcome

    Directory of Open Access Journals (Sweden)

    Bilal Chughtai

    2008-01-01

    Full Text Available Introduction. The aim of this study is to examine the feasibility of reducing postoperative hospital stay following open partial nephrectomy through the implementation of a goal directed clinical management pathway. Materials and Methods. A fast track clinical pathway for open partial nephrectomy was introduced in July 2006 at our institution. The pathway has daily goals and targets discharge for all patients on the 3rd postoperative day (POD. Defined goals are (1 ambulation and liquid diet on the evening of the operative day; (2 out of bed (OOB at least 4 times on POD 1; (3 removal of Foley catheter on the morning of POD 2; (4 removal of Jackson Pratt drain on the afternoon of POD 2; (4 discharge to home on POD 3. Patients and family are instructed in the fast track protocol preoperatively. Demographic data, tumor size, length of stay, and complications were captured in a prospective database, and compared to a control group managed consecutively immediately preceding the institution of the fast track clinical pathway. Results. Data on 33 consecutive patients managed on the fast track clinical pathway was compared to that of 25 control patients. Twenty two (61% out of 36 fast track patients and 4 (16% out of 25 control patients achieved discharge on POD 3. Overall, fast track patients had a shorter hospital stay than controls (median, 3 versus 4 days; P = .012. Age (median, 55 versus 57 years, tumor size (median, 2.5 versus 2.5 cm, readmission within 30 days (5.5% versus 5.1%, and complications (10.2% versus 13.8% were similar in the fast track patients and control, respectively. Conclusions. In the present series, a fast track clinical pathway after open partial nephrectomy reduced the postoperative length of hospital stay and did not appear to increase the postoperative complication rate.

  4. Hardware-based Tracking at Trigger Level for ATLAS: The Fast TracKer (FTK) Project

    CERN Document Server

    Gramling, Johanna; The ATLAS collaboration

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer (FTK) is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level 1 trigger (at a maximum rate of 100 kHz) the FTK receives data from the 80 million channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware- based track reconstruction, using associative memory (AM) that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. Narrow roads permit a fast track fitting but need many patterns stored in the AM to ensure...

  5. Research on Precision Tracking on Fast Steering Mirror and Control Strategy

    Science.gov (United States)

    Di, Lin; Yi-ming, Wu; Fan, Zhu

    2018-01-01

    Fast steering mirror is a device used for controlling the beam direction precisely. Due to the short travel of the push-pull FSM, a compound fast steering mirror system driven by both limited-angle voice coil motor and push-pull FSM together is proposed. In the compound FSM system, limited-angle voice coil motor quickly swings at wide angle, while the push-pull FSM do high frequency movement in a small range, which provides the system with the high bandwidth and long travel. In the control strategy, the method of combining feed-forward control in Kalman filtering with auto-disturbance rejection control is used to improve trajectory tracking accuracy. The simulation result shows that tracking accuracy measured by the compound method can be improved by more than 5 times than that of the conventional PID.

  6. Patient-reported outcome after fast-track hip arthroplasty: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Hansen Torben B

    2010-11-01

    Full Text Available Abstract Background A fast-track intervention with a short preoperative optimization period and short postoperative hospitalization has a potential for reduced convalescence and thereby a reduced need for postoperative rehabilitation. The purpose of this study was to describe patient-related outcomes, the need for additional rehabilitation after a fast-track total hip arthroplasty (THA, and the association between generic and disease specific outcomes. Methods The study consisted of 196 consecutive patients of which none received additional rehabilitation beyond an instructional exercise plan at discharge, which was adjusted at one in-patient visit. The patients filled in 3 questionnaires to measure health-related quality-of-life (HRQOL and hip specific function (EQ-5 D, SF36, and Harris Hip Score (HHS at 2 time points pre- and 2 time points postoperatively. The observed results were compared to normative population data for EQ-5 D, SF36, and HHS. Results 3-months postoperatively patients had reached a HRQOL level of 0.84 (SD, 0.14, which was similar to the population norm (P = 0.33, whereas they exceeded the population norm at 12 months postoperatively (P P P = 0.35. For HHS, patients never reached the population norm within 12 months postoperatively. Generic and disease specific outcomes were strongly associated. Conclusions If HRQOL is considered the primary outcome after THA, the need for additional postoperative rehabilitation for all THA patients following a fast-track intervention is questionable. However, a pre- or early postoperative physical intervention seems relevant if the PF of the population norm should be reached at 3 months. If disease specific outcome is considered the primary outcome after fast-track THA, clear goals for the rehabilitation must be established before patient selection, intervention type and timing of intervention can be made.

  7. FAST: A fully asynchronous and status-tracking pattern for geoprocessing services orchestration

    Science.gov (United States)

    Wu, Huayi; You, Lan; Gui, Zhipeng; Gao, Shuang; Li, Zhenqiang; Yu, Jingmin

    2014-09-01

    Geoprocessing service orchestration (GSO) provides a unified and flexible way to implement cross-application, long-lived, and multi-step geoprocessing service workflows by coordinating geoprocessing services collaboratively. Usually, geoprocessing services and geoprocessing service workflows are data and/or computing intensive. The intensity feature may make the execution process of a workflow time-consuming. Since it initials an execution request without blocking other interactions on the client side, an asynchronous mechanism is especially appropriate for GSO workflows. Many critical problems remain to be solved in existing asynchronous patterns for GSO including difficulties in improving performance, status tracking, and clarifying the workflow structure. These problems are a challenge when orchestrating performance efficiency, making statuses instantly available, and constructing clearly structured GSO workflows. A Fully Asynchronous and Status-Tracking (FAST) pattern that adopts asynchronous interactions throughout the whole communication tier of a workflow is proposed for GSO. The proposed FAST pattern includes a mechanism that actively pushes the latest status to clients instantly and economically. An independent proxy was designed to isolate the status tracking logic from the geoprocessing business logic, which assists the formation of a clear GSO workflow structure. A workflow was implemented in the FAST pattern to simulate the flooding process in the Poyang Lake region. Experimental results show that the proposed FAST pattern can efficiently tackle data/computing intensive geoprocessing tasks. The performance of all collaborative partners was improved due to the asynchronous mechanism throughout communication tier. A status-tracking mechanism helps users retrieve the latest running status of a GSO workflow in an efficient and instant way. The clear structure of the GSO workflow lowers the barriers for geospatial domain experts and model designers to

  8. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial

    Directory of Open Access Journals (Sweden)

    Swart Annemiek

    2006-11-01

    Full Text Available Abstract Background Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay. The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst track multimodal management versus standard care was conceived to determine whether laparoscopic surgery, fast track perioperative care or a combination of both is to be preferred over open surgery with standard care in patients having segmental colectomy for malignant disease. Methods/design The LAFA-trial is a double blinded, multicenter trial with a 2 × 2 balanced factorial design. Patients eligible for segmental colectomy for malignant colorectal disease i.e. right and left colectomy and anterior resection will be randomized to either open or laparoscopic colectomy, and to either standard care or the fast track program. This factorial design produces four treatment groups; open colectomy with standard care (a, open colectomy with fast track program (b, laparoscopic colectomy with standard care (c, and laparoscopic surgery with fast track program (d. Primary outcome parameter is postoperative hospital length of stay including readmission within 30 days. Secondary outcome parameters are quality of life two and four weeks after surgery, overall hospital costs, morbidity, patient satisfaction and readmission rate. Based on a mean postoperative hospital stay of 9 +/- 2.5 days a group size of 400 patients (100 each arm can reliably detect a minimum difference of 1 day between the four arms (alfa = 0.95, beta = 0.8. With 100 patients in each arm a difference of 10% in subscales of the Short Form 36 (SF-36 questionnaire and social functioning can be detected. Discussion The LAFA-trial is a randomized controlled multicenter trial that will provide evidence on the merits of fast track perioperative care and laparoscopic colorectal surgery in

  9. Faraday Rotation Measurement with the SMAP Radiometer

    Science.gov (United States)

    Le Vine, D. M.; Abraham, S.

    2016-01-01

    Faraday rotation is an issue that needs to be taken into account in remote sensing of parameters such as soil moisture and ocean salinity at L-band. This is especially important for SMAP because Faraday rotation varies with azimuth around the conical scan. SMAP retrieves Faraday rotation in situ using the ratio of the third and second Stokes parameters, a procedure that was demonstrated successfully by Aquarius. This manuscript reports the performance of this algorithm on SMAP. Over ocean the process works reasonably well and results compare favorably with expected values. But over land, the inhomogeneous nature of the scene results in much noisier, and in some cases unreliable estimates of Faraday rotation.

  10. Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator

    International Nuclear Information System (INIS)

    Castillo, F.; Espinosa, G.; Golzarri, J.I.; Osorio, D.; Rangel, J.; Reyes, P.G.; Herrera, J.J.E.

    2013-01-01

    The chemical etching parameters (etching time, temperature, normality of etchant, etc.) for the use of CR-39 (allyl diglycol carbonate – Lantrack ® ) as a fast neutron dosimeter have been optimized. The CR-39 chips, placed under a 1.5 mm polyethylene radiator, were exposed for calibration to an 241 Am-Be source at different time intervals for a given neutron fluence. After several chemical etching processes of the detectors with different conditions, the optimum characteristics for the chemical etching were found at 6N KOH solution, 60 ± 1 °C, for 12 h. An accurate relationship between the dose and fluence calculations was obtained as a function of the track density. - Highlights: ► Optimum etching time for fast neutron irradiated CR-39 track detectors is found. ► Relationship between dose and fluence obtained as a function of the track density. ► Results are consistent with those reported elsewhere, and extend the dose range

  11. Magneto-optical Faraday spectroscopy of completely bismuth-substituted Bi3Fe5O12 garnet thin films

    International Nuclear Information System (INIS)

    Deb, M; Popova, E; Fouchet, A; Keller, N

    2012-01-01

    We performed a magneto-optical (MO) Faraday spectroscopy study of bismuth iron garnet Bi 3 Fe 5 O 12 thin single-crystalline films with thickness from 5 to 220 nm. The Faraday rotation and ellipticity spectra were measured for photon energies ranging from 1.7 to 4.2 eV. Using a model based on two electric dipole transitions associated with tetrahedral and octahedral iron sites, we successfully reproduce the observed rotation and ellipticity spectra. The sign of both site contributions to the Faraday rotation and ellipticity spectra has been used to interpret the complex thermal dependence of the Faraday rotation and ellipticity. For a Faraday ellipticity, anomalous hysteresis loops have been observed around specific photon energies. To explain the surprising shape of hysteresis loop, a model based on the superposition of two hysteresis loops with opposite sign associated with both sites is proposed. The modelling of these hysteresis loops allows accessing the magnetic properties of each individual sublattice. Finally, we have studied the dependence of the energy level parameters on bismuth content in Yi 3-x Bi x Fe 5 O 12 garnet and on the thickness of bismuth iron garnet. Based on this analysis, we show that MO spectroscopy is a fast and non-destructive technique to determine the bi-deficiency of BIG films.

  12. Avoiding ICU Admission by Using a Fast-Track Protocol Is Safe in Selected Adult-to-Adult Live Donor Liver Transplant Recipients

    Directory of Open Access Journals (Sweden)

    Juan Echeverri, MD

    2017-10-01

    Full Text Available Background. We evaluated patient characteristics of live donor liver transplant (LDLT recipients undergoing a fast-track protocol without intensive care unit (ICU admission versus LDLT patients receiving posttransplant ICU care. Methods. Of the 153 LDLT recipients, 46 patients were included in our fast-track protocol without ICU admission. Both, fast-tracked patients and ICU-admitted patients were compared regarding donor and patient characteristics, perioperative characteristics, and postoperative outcomes and complications. In a subgroup analysis, we compared fast-tracked patients with patients who were admitted in the ICU for less than 24 hours. Results. Fast-tracked versus ICU patients had a lower model for end-stage liver disease score (13 ± 4 vs 18 ± 7; P < 0.0001, lower preoperative bilirubin levels (51 ± 50 μmol/L vs 119.4 ± 137.3 μmol/L; P < 0.001, required fewer units of packed red blood cells (1.7 ± 1.78 vs 4.4 ± 4; P < 0.0001, and less fresh-frozen plasma (2.7 ± 2 vs 5.8 ± 5; P < 0.0001 during transplantation. Regarding postoperative outcomes, fast-tracked patients presented fewer bacterial infections within 30 days (6.5% [3] vs 29% [28]; P = 0.002, no episodes of pneumonia (0% vs 11.3% [11]; P = 0.02, and less biliary complications within the first year (6% [3] vs 26% [25]; P = 0.001. Also, fast-tracked patients had a shorter posttransplant hospital stay (10.8 ± 5 vs 21.3 ± 29; P = 0.002. In the subgroup analysis, fast-tracked vs ICU patients admitted for less than 24 hours had lower requirements of packed red blood cells (1.7 ± 1.78 vs 3.9 ± 4; P = 0.001 and fresh-frozen plasma (2.7 ± 2 vs 5.8 ± 4.5; P = 0.0001. Conclusions. Fast-track of selected patients after LDLT is safe and feasible. An objective score to perioperatively select LDLT recipients amenable to fast track is yet to be determined.

  13. Faraday instability of crystallization waves in 4He

    International Nuclear Information System (INIS)

    Abe, H; Ueda, T; Morikawa, M; Saitoh, Y; Nomura, R; Okuda, Y

    2007-01-01

    Periodic modulation of the gravity acceleration makes a flat surface of a fluid unstable and standing waves are parametrically excited on the surface. This phenomenon is called Faraday instability. Since a crystal-superfluid interface of 4 He at low temperatures is very mobile and behaves like a fluid surface, Saarloos and Weeks predicted that Faraday instability of the crystallization waves exists in 4 He and that the threshold excitation for the instability depends on the crystal growth coefficient. We successfully observed the Faraday instability of the crystal-liquid interface at 160 mK. Faraday waves were parametrically generated at one half of the driving frequency 90 Hz. Amplitude of the Faraday wave becomes smaller at higher temperature due to decrease of the crystal growth coefficient and disappears above 200 mK

  14. Nonreciprocal plasmonics enables giant enhancement of thin-film Faraday rotation.

    Science.gov (United States)

    Chin, Jessie Yao; Steinle, Tobias; Wehlus, Thomas; Dregely, Daniel; Weiss, Thomas; Belotelov, Vladimir I; Stritzker, Bernd; Giessen, Harald

    2013-01-01

    Light propagation is usually reciprocal. However, a static magnetic field along the propagation direction can break the time-reversal symmetry in the presence of magneto-optical materials. The Faraday effect in magneto-optical materials rotates the polarization plane of light, and when light travels backward the polarization is further rotated. This is applied in optical isolators, which are of crucial importance in optical systems. Faraday isolators are typically bulky due to the weak Faraday effect of available magneto-optical materials. The growing research endeavour in integrated optics demands thin-film Faraday rotators and enhancement of the Faraday effect. Here, we report significant enhancement of Faraday rotation by hybridizing plasmonics with magneto-optics. By fabricating plasmonic nanostructures on laser-deposited magneto-optical thin films, Faraday rotation is enhanced by one order of magnitude in our experiment, while high transparency is maintained. We elucidate the enhanced Faraday effect by the interplay between plasmons and different photonic waveguide modes in our system.

  15. Design and modeling of Faraday cages for substrate noise isolation

    Science.gov (United States)

    Wu, Joyce H.; del Alamo, Jesús A.

    2013-07-01

    A Faraday cage structure using through-substrate vias is an effective strategy to suppress substrate crosstalk, particularly at high frequencies. Faraday cages can reduce substrate noise by 32 dB at 10 GHz, and 26 dB at 50 GHz. We have developed lumped-element, equivalent circuit models of the Faraday cages and test structures to better understand the performance of the Faraday cages. These models compare well to measured results and show that the vias of the Faraday cage act as an RLC shunt to ground that draws substrate current. Designing a Faraday cage to achieve optimum isolation requires low via impedance and mitigation of via sidewall capacitance. The Faraday cage inductance is correlated to the number of vias and via spacing of the cage and can be optimized for the frequency of operation.

  16. Reconfigurable antennas radiations using plasma Faraday cage

    OpenAIRE

    Barro , Oumar Alassane; Himdi , Mohamed; Lafond , Olivier

    2015-01-01

    International audience; This letter presents a new reconfigurable plasma antenna associated with a Faraday cage. The Faraday cage is realized using a fluorescent lamp. A patch antenna with a broadside radiation pattern or a monopole antenna with an end-fire radiation pattern , operating at 2.45 GHz, is placed inside Faraday cage. The performance of the reconfigurable system is observed in terms of input reflection coefficient, gain and radiation pattern via simulation and measurement. It is s...

  17. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been s...... speculated that a decrease in LOS may be associated with an increase in readmissions in general, including risk of dislocation after total hip arthroplasty (THA) or manipulation after total knee arthroplasty (TKA)....

  18. Tensor B mode and stochastic Faraday mixing

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    This paper investigates the Faraday effect as a different source of B mode polarization. The E mode polarization is Faraday rotated provided a stochastic large-scale magnetic field is present prior to photon decoupling. In the first part of the paper we discuss the case where the tensor modes of the geometry are absent and we argue that the B mode recently detected by the Bicep2 collaboration cannot be explained by a large-scale magnetic field rotating, through the Faraday effect, the well established E mode polarization. In this case, the observed temperature autocorrelations would be excessively distorted by the magnetic field. In the second part of the paper the formation of Faraday rotation is treated as a stationary, random and Markovian process with the aim of generalizing a set of scaling laws originally derived in the absence of the tensor modes of the geometry. We show that the scalar, vector and tensor modes of the brightness perturbations can all be Faraday rotated even if the vector and tensor par...

  19. Rethinking Faraday's law for teaching motional electromotive force

    International Nuclear Information System (INIS)

    Zuza, Kristina; Guisasola, Jenaro; Michelini, Marisa; Santi, Lorenzo

    2012-01-01

    This study shows physicists' discussions on the meaning of Faraday's law where situations involving extended conductors or moving contact points are particularly troublesome. We raise questions to test students' difficulties in applying Faraday's law in motional electromotive force phenomena. We suggest the benefit of analysing these phenomena when teaching Faraday's law in introductory physics courses at university. We are not implying that Faraday's law should be revised, but we do want to set the stage for careful rethinking regarding the meaning and application of each term of the law as it appears in traditional introductory courses. (paper)

  20. [Shortened hospital stay for elective cesarean section after initiation of a fast-track program and midwifery home-care].

    Science.gov (United States)

    Gunnarsdottir, Johanna; Bjornsdottir, Thorbjörg Edda; Halldorsson, Thorhallur Ingi; Halldorsdottir, Gudrun; Geirsson, Reynir Tomas

    2011-07-01

    To audit whether hospital stay shortened without increasing readmissions after implementation of fast-track methodology for elective cesarean section and characterize what influences length of stay. A fast-track program was initiated in November 2008, with a one year clinical audit and satisfaction survey. Discharge criteria were predefined and midwife home visits included if discharge was within 48 hours. Hospital stay by parity for women with elective section for singleton pregnancy between 1.11. 2008 - 31.10. 2009 (n=213, fast-track 182) was compared to 2003 (n=199) and 2007 (n=183). Readmissions and outpatient visits 2007 and 2008-9 were counted. Reasons for longer stay were recorded in fast-track, and body mass index. Median hospital stay decreased significantly from 81 to 52 hours between 2007 and 2008-9. Readmissions were four in each period and outpatient visit rates similar. In 2008-9, 66% of all women were discharged within 48 hours. Women in the fast-track program were satisfied with early discharge. Hospital stay for parous women was shorter in 2007 compared to 2003, but unchanged for nulliparas. Parity had a minimal influence on length of stay in 2008-9, although nulliparous women ≤ 25 years were more likely to stay >48 hours. Body mass index did not correlate with length of stay. Pain was rarely the reason for a longer stay in the fast-track program and 90% were satisfied with pain-medication after discharge. Most healthy women can be discharged early after singleton birth by elective cesarean, without increasing readmissions.

  1. Subacute pain and function after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Østergaard; Gaarn-Larsen, L; Kristensen, B B

    2009-01-01

    In a well-defined fast-track setup for total hip and knee arthroplasty, with a multimodal analgesic regimen consisting of intra-operative local anaesthetic infiltration and oral celecoxib, gabapentin and paracetamol for 6 days postoperatively, we conducted a prospective, consecutive, observationa...

  2. Evaluation of a fast-track programme for patients undergoing liver resection

    DEFF Research Database (Denmark)

    Schultz, Nicolai A.; Larsen, Peter Nørgaard; Klarskov, Birthe Michaelsen

    2013-01-01

    BACKGROUND: Recent developments in perioperative pathophysiology and care have documented evidence-based, multimodal rehabilitation (fast-track) to hasten recovery and to decrease morbidity and hospital stay for several major surgical procedures. The aim of this study was to investigate the effect...

  3. Generalized Faraday law derived from classical forces in a rotating frame

    OpenAIRE

    Choi, Taeseung

    2009-01-01

    We show the additional spin dependent classical force due to the rotation of an electron spin's rest frame is essential to derive a spin-Faraday law by using an analogy with the usual Faraday law. The contribution of the additional spin dependent force to the spin-Faraday law is the same as that of the spin geometric phase. With this observations, Faraday law is generalized to include both the usual Faraday and the spin-Faraday laws in a unified manner.

  4. Fast Track Finding in the ILC's Silicon Detector, SiD01

    International Nuclear Information System (INIS)

    Baker, David E.

    2007-01-01

    A fast track finder is presented which, unlike its more efficient, more computationally costly O(n3) time counterparts, tracks particles in O(n) time (for n being the number of hits). Developed as a tool for processing data from the ILC's proposed SiD detector, development of this fast track finder began with that proposed by Pablo Yepes in 1996 and adjusted to accommodate the changes in geometry of the SiD detector. First, space within the detector is voxellated, with hits assigned to voxels according to their r, φ, and η coordinates. A hit on the outermost layer is selected, and a 'sample space' is built from the hits in the selected hit's surrounding voxels. The hit in the sample space with the smallest distance to the first is then selected, and the sample space recalculated for this hit. This process continues until the list of hits becomes large enough, at which point the helical circle in the x, y plane is conformally mapped to a line in the x', y' plane, and hits are chosen from the sample spaces of the previous fit by selecting the hits which fit a line to the previously selected points with the smallest χ 2 . Track finding terminates when the innermost layer has been reached or no hit in the sample space fits those previously selected to an acceptable χ 2 . Again, a hit on the outermost layer is selected and the process repeats until no assignable hits remain. The algorithm proved to be very efficient on artificial diagnostic events, such as one hundred muons scattered at momenta of 1 GeV/c to 10 GeV/c. Unfortunately, when tracking simulated events corresponding to actual physics, the track finder's efficiency decreased drastically (mostly due to signal noise), though future data cleaning programs could noticeably increase its efficiency on these events

  5. B polarization of the CMB from Faraday rotation

    International Nuclear Information System (INIS)

    Scoccola, Claudia; Harari, Diego; Mollerach, Silvia

    2004-01-01

    We study the effect of Faraday rotation due to a uniform magnetic field on the polarization of the cosmic microwave background. Scalar fluctuations give rise only to parity-even E-type polarization of the cosmic microwave background. However in the presence of a magnetic field, a nonvanishing parity-odd B-type polarization component is produced through Faraday rotation. We derive the exact solution for the E and B modes generated by scalar perturbations including the Faraday rotation effect of a uniform magnetic field, and evaluate their cross correlations with temperature anisotropies. We compute the angular autocorrelation function of the B-modes in the limit that the Faraday rotation is small. We find that uniform primordial magnetic fields of present strength around B 0 =10 -9 G rotate E-modes into B-modes with amplitude comparable to those due to the weak gravitational lensing effect at frequencies around ν=30 GHz. The strength of B-modes produced by Faraday rotation scales as B 0 /ν 2 . We evaluate also the depolarizing effect of Faraday rotation upon the cross correlation between temperature anisotropy and E-type polarization

  6. Fast track multi-discipline treatment (FTMDT trial versus conventional treatment in colorectal cancer--the design of a prospective randomized controlled study

    Directory of Open Access Journals (Sweden)

    Zhou Jiao-Jiao

    2011-11-01

    Full Text Available Abstract Background Laparoscopy-assisted surgery, fast-track perioperative treatment are both increasingly used in colorectal cancer treatment, for their short-time benefits of enhanced recovery and short hospital stays. However, the benefits of the integration of the Laparoscopy-assisted surgery, fast-track perioperative treatment, and even with the Xelox chemotherapy, are still unknown. In this study, the three treatments integration is defined as "Fast Track Multi-Discipline Treatment Model" for colorectal cancer and this model extends the benefits to the whole treatment process of colorectal cancer. The main purpose of the study is to explore the feasibility of "Fast Track Multi-Discipline Treatment" model in treatment of colorectal cancer. Methods The trial is a prospective randomized controlled study with 2 × 2 balanced factorial design. Patients eligible for the study will be randomized to 4 groups: (I Laparoscopic surgery with fast track perioperative treatment and Xelox chemotherapy; (II Open surgery with fast track perioperative treatment and Xelox chemotherapy; (III Laparoscopic surgery with conventional perioperative treatment and mFolfox6 chemotherapy; (IV Open surgery with conventional perioperative treatment and mFolfox6 chemotherapy. The primary endpoint of this study is the hospital stays. The secondary endpoints are the quality of life, chemotherapy related adverse events, surgical complications and hospitalization costs. Totally, 340 patients will be enrolled with 85 patients in each group. Conclusions The study initiates a new treatment model "Fast Track Multi-Discipline Treatment" for colorectal cancer, and will provide feasibility evidence on the new model "Fast Track Multi-Discipline Treatment" for patients with colorectal cancer. Trial registration ClinicalTrials.gov: NCT01080547

  7. Faraday instability on patterned surfaces

    Science.gov (United States)

    Feng, Jie; Rubinstein, Gregory; Jacobi, Ian; Stone, Howard

    2013-11-01

    We show how micro-scale surface patterning can be used to control the onset of the Faraday instability in thin liquid films. It is well known that when a liquid film on a planar substrate is subject to sufficient vibrational accelerations, the free surface destabilizes, exhibiting a family of non-linear standing waves. This instability remains a canonical problem in the study of spontaneous pattern formation, but also has practical uses. For example, the surface waves induced by the Faraday instability have been studied as a means of enhanced damping for mechanical vibrations (Genevaux et al. 2009). Also the streaming within the unstable layer has been used as a method for distributing heterogeneous cell cultures on growth medium (Takagi et al. 2002). In each of these applications, the roughness of the substrate significantly affects the unstable flow field. We consider the effect of patterned substrates on the onset and behavior of the Faraday instability over a range of pattern geometries and feature heights where the liquid layer is thicker than the pattern height. Also, we describe a physical model for the influence of patterned roughness on the destabilization of a liquid layer in order to improve the design of practical systems which exploit the Faraday instability.

  8. ICRF antenna Faraday shield plasma sheath model

    International Nuclear Information System (INIS)

    Whealton, J.H.; Ryan, P.M.; Raridon, R.J.

    1990-01-01

    A two-dimensional nonlinear formulation that explicitly considers the plasma edge near a Faraday shield in a self-consistent manner is used in the modeling of the ion motion for a Faraday shield concept and model suggested by Perkins. Two models are considered that may provide significant insight into the generation of impurities for ion cyclotron resonance heating (ICRH) antennas. In one of these models a significant sheath periodically forms next to the Faraday screen, with ion acoustic waves heating the ions in the plasma. (orig.)

  9. Faraday effect in hollow quantum cylinder of finite thickness

    International Nuclear Information System (INIS)

    Ismailov, T.G.; Jabrailova, G.G.

    2009-01-01

    The interband Faraday rotation in hollow quantum cylinder of finite thickness is theoretically investigated. Faraday rotation in the dependence on incident light energy for different values of cylinder thickness. It is seen that the resonance peaks appear on Faraday rotation curve. The roles of selection are obtained

  10. Maintaining Unity - relatives in older patients' fast-track treatment programmes. A grounded theory study.

    Science.gov (United States)

    Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten

    2014-12-01

    To generate a substantive grounded theory of relatives' pattern of behaviour in older patients' fast-track treatment programmes during total hip or knee replacement. Fast-track treatment programmes are designed to make total hip and knee replacements more efficient through recovery improvements. The support of relatives during older patients' trajectory is important. However, knowledge is needed on the relatives' pattern of behaviour to strengthen their involvement in fast-track treatment programmes. We used a Glaserian grounded theory approach based on a systematic generation of theory from data to explain the latent pattern of behaviour of relatives. Data were collected from 2010-2011 in orthopaedic wards at two Danish university hospitals and consisted of 14 non-participant observations, 14 postobservational interviews and five interviews. Seven relatives of patients over 70 years of age participated. The constant comparative method was the guiding principle for simultaneous data collection, data analysis and coding, while theoretically sampling and writing memos. Maintaining Unity emerged as the relatives' pattern of behaviour through which they resolved their main concern: preventing the patients from feeling alone. The relatives resolved their main concern through three interchangeable behavioural modes: Protecting Mode, by providing loving and respectful support; Substituting Mode, with practical and cognitive support; and an Adapting Mode, by trying to fit in with the patients' and health professionals' requirements. The substantive theory of Maintaining Unity offers knowledge of relatives' strong desire to provide compassionate and loving support for the older patients during fast-track treatment programmes. © 2014 John Wiley & Sons Ltd.

  11. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty; a detailed observational cohort study

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  12. The correspondance of Michael Faraday

    CERN Document Server

    1991-01-01

    The initial volume of the correspondence of Micahel Faraday (1791-1867), published in the year of the bicentenary of his birth, covers his early years up to his discovery of electromagnetic induction in 1831. Other scientific and technical topics covered include Faraday's discovery of electromagnetic rotations (in 1821), the liquefaction of gases (in 1823) and the long series of experiments in the latter part of the 1820s to improve optical glass.

  13. Faraday rotation measurements at Ootacamund

    Science.gov (United States)

    Sethia, G.; Chandra, H.; Deshpande, M. R.; Rastogi, R. G.

    1978-01-01

    The results of Faraday rotation measurements made at Ootacamund during ATS-6 phase II are presented. For summer and equinoctial months, even though no clear noon bite-out is observed in the variation of Faraday a decrease is observed in the rate of increase of rotation around 0900-1000 hours LT. This is attributed to the 'fountain effect' which is responsible for the noontime bite-out in F2-region peak electron density.

  14. When is it optimal to delegate: the theory of fast-track authority

    Czech Academy of Sciences Publication Activity Database

    Celik, Levent; Karabay, B.; McLaren, J.

    2015-01-01

    Roč. 7, č. 3 (2015), s. 347-389 ISSN 1945-7669 Institutional support: RVO:67985998 Keywords : fast-track authority * free trade * protectionist rents Subject RIV: AH - Economics Impact factor: 1.359, year: 2015

  15. The gravitational analog of Faraday's induction law

    Science.gov (United States)

    Zile, Daniel; Overduin, James

    2015-04-01

    Michael Faraday, the discoverer of electromagnetic induction, was convinced that there must also be a gravitational analog of this law, and he carried out drop-tower experiments in 1849 to look for the electric current induced in a coil by changes in gravitational flux through the coil. This work, now little remembered, was in some ways the first investigation of what we would now call a unified-field theory. We revisit Faraday's experiments in the light of current knowledge and ask what might be learned if they were to be performed today. We then review the gravitational analog for Faraday's law that arises within the vector (or gravito-electromagnetic) approximation to Einstein's theory of general relativity in the weak-field, low-velocity limit. This law relates spinning masses and induced ``mass currents'' rather than spinning charges and electric currents, but is otherwise remarkably similar to its electromagnetic counterpart. The predicted effects are completely unobservable in everyday settings like those envisioned by Faraday, but are thought to be relevant in astrophysical contexts like the accretion disks around collapsed stars, thus bearing out Faraday's remarkable intuition. Undergraduate student.

  16. Role of patient characteristics for fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C.; Jacobsen, M; Søballe, Kjeld

    2013-01-01

    BACKGROUND: /st>Patient age and comorbidity have been found to increase the length of hospital stay (LOS), readmissions, and mortality after surgery, including in elective primary total hip arthroplasty (THA) and total knee arthroplasty (TKA). Whether the same applies in fast-track THA and TKA...

  17. SCIENTIFIC VERIFICATION OF FARADAY ROTATION MODULATORS: DETECTION OF DIFFUSE POLARIZED GALACTIC EMISSION

    Energy Technology Data Exchange (ETDEWEB)

    Moyerman, S.; Bierman, E.; Kaufman, J.; Keating, B. G. [Center for Astrophysics and Space Sciences, University of California, San Diego, CA 92037 (United States); Ade, P. A. R. [Department of Physics and Astronomy, University of Wales, Cardiff CF24 3YB (United Kingdom); Aiken, R.; Hristov, V. V.; Jones, W. C.; Mason, P. V. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Bischoff, C.; Kovac, J. M. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Bock, J. J.; Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Chiang, H. C. [Department of Physics, Princeton University, Princeton, NJ 08544 (United States); Duband, L. [SBT, Commissariat a l' Energie Atomique (apostrophe), F-38054 Grenoble (France); Hivon, E. F. [Insititut d' Astrophysique de Paris, F-75014 Paris (France); Holzapfel, W. L. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720 (United States); Kuo, C. L. [Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, Palo Alto, CA 94305 (United States); Leitch, E. M., E-mail: smoyerma@ucsd.edu [Kavli Institute for Cosmological Physics, University of Chicago, Chicago, IL 60637 (United States); and others

    2013-03-01

    The design and performance of a wide bandwidth linear polarization modulator based on the Faraday effect is described. Faraday Rotation Modulators (FRMs) are solid-state polarization switches that are capable of modulation up to 10 kHz. Six FRMs were utilized during the 2006 observing season in the Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment; three FRMs were used at each of BICEP's 100 and 150 GHz frequency bands. The technology was verified through high signal-to-noise detection of Galactic polarization using two of the six FRMs during four observing runs in 2006. The features exhibit strong agreement with BICEP's measurements of the Galaxy using non-FRM pixels and with the Galactic polarization models. This marks the first detection of high signal-to-noise mm-wave celestial polarization using fast, active optical modulation. The performance of the FRMs during periods when they were not modulated was also analyzed and compared to results from BICEP's 43 pixels without FRMs.

  18. Scientific Verification of Faraday Rotation Modulators: Detection of Diffuse Polarized Galactic Emission

    Science.gov (United States)

    Moyerman, S.; Bierman, E.; Ade, P. A. R.; Aiken, R.; Barkats, D.; Bischoff, C.; Bock, J. J.; Chiang, H. C.; Dowell, C. D.; Duband, L.; hide

    2012-01-01

    The design and performance of a wide bandwidth linear polarization-modulator based on the Faraday effect is described. Faraday Rotation Modulators (FRMs) are solid-state polarization switches that are capable of modulation up to approx 10 kHz. Six FRMs were utilized during the 2006 observing season in the Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment; three FRMs were used at each of BICEP fs 100 and 150 GHz frequency bands. The technology was verified through high signal-to-noise detection of Galactic polarization using two of the six FRMs during four observing runs in 2006. The features exhibit strong agreement with BICEP fs measurements of the Galaxy using non-FRM pixels and with the Galactic polarization models. This marks the first detection of high signal-to-noise mm-wave celestial polarization using fast, active optical modulation. The performance of the FRMs during periods when they were not modulated was also analyzed and compared to results from BICEP fs 43 pixels without FRMs.

  19. Fast track surgery at the University Teaching Hospital of Kigali: a ...

    African Journals Online (AJOL)

    Background: Fast Track Surgery is synonymous with Enhanced Recovery after Surgery. It was started in the 1990's initially for colorectal surgery, but later became applicable to other aspects of surgery. Its core elements include epidural or regional anaesthesia, perioperative fluid management, minimally invasive surgical ...

  20. Evaluation of beam tracking strategies for the THOR-CSW solar wind instrument

    Science.gov (United States)

    De Keyser, Johan; Lavraud, Benoit; Prech, Lubomir; Neefs, Eddy; Berkenbosch, Sophie; Beeckman, Bram; Maggiolo, Romain; Fedorov, Andrei; Baruah, Rituparna; Wong, King-Wah; Amoros, Carine; Mathon, Romain; Génot, Vincent

    2017-04-01

    We compare different beam tracking strategies for the Cold Solar Wind (CSW) plasma spectrometer on the ESA M4 THOR mission candidate. The goal is to intelligently select the energy and angular windows the instrument is sampling and to adapt these windows as the solar wind properties evolve, with the aim to maximize the velocity distribution acquisition rate while maintaining excellent energy and angular resolution. Using synthetic data constructed using high-cadence measurements by the Faraday cup instrument on the Spektr-R mission (30 ms resolution), we test the performance of energy beam tracking with or without angular beam tracking. The algorithm can be fed both by data acquired by the plasma spectrometer during the previous measurement cycle, or by data from another instrument, in casu the Faraday Cup (FAR) instrument foreseen on THOR. We verify how these beam tracking algorithms behave for different sizes of the energy and angular windows, and for different data integration times, in order to assess the limitations of the algorithm and to avoid situations in which the algorithm loses track of the beam.

  1. Fast Compressive Tracking.

    Science.gov (United States)

    Zhang, Kaihua; Zhang, Lei; Yang, Ming-Hsuan

    2014-10-01

    It is a challenging task to develop effective and efficient appearance models for robust object tracking due to factors such as pose variation, illumination change, occlusion, and motion blur. Existing online tracking algorithms often update models with samples from observations in recent frames. Despite much success has been demonstrated, numerous issues remain to be addressed. First, while these adaptive appearance models are data-dependent, there does not exist sufficient amount of data for online algorithms to learn at the outset. Second, online tracking algorithms often encounter the drift problems. As a result of self-taught learning, misaligned samples are likely to be added and degrade the appearance models. In this paper, we propose a simple yet effective and efficient tracking algorithm with an appearance model based on features extracted from a multiscale image feature space with data-independent basis. The proposed appearance model employs non-adaptive random projections that preserve the structure of the image feature space of objects. A very sparse measurement matrix is constructed to efficiently extract the features for the appearance model. We compress sample images of the foreground target and the background using the same sparse measurement matrix. The tracking task is formulated as a binary classification via a naive Bayes classifier with online update in the compressed domain. A coarse-to-fine search strategy is adopted to further reduce the computational complexity in the detection procedure. The proposed compressive tracking algorithm runs in real-time and performs favorably against state-of-the-art methods on challenging sequences in terms of efficiency, accuracy and robustness.

  2. Faraday's first dynamo: A retrospective

    Science.gov (United States)

    Smith, Glenn S.

    2013-12-01

    In the early 1830s, Michael Faraday performed his seminal experimental research on electromagnetic induction, in which he created the first electric dynamo—a machine for continuously converting rotational mechanical energy into electrical energy. His machine was a conducting disc, rotating between the poles of a permanent magnet, with the voltage/current obtained from brushes contacting the disc. In his first dynamo, the magnetic field was asymmetric with respect to the axis of the disc. This is to be contrasted with some of his later symmetric designs, which are the ones almost invariably discussed in textbooks on electromagnetism. In this paper, a theoretical analysis is developed for Faraday's first dynamo. From this analysis, the eddy currents in the disc and the open-circuit voltage for arbitrary positioning of the brushes are determined. The approximate analysis is verified by comparing theoretical results with measurements made on an experimental recreation of the dynamo. Quantitative results from the analysis are used to elucidate Faraday's qualitative observations, from which he learned so much about electromagnetic induction. For the asymmetric design, the eddy currents in the disc dissipate energy that makes the dynamo inefficient, prohibiting its use as a practical generator of electric power. Faraday's experiments with his first dynamo provided valuable insight into electromagnetic induction, and this insight was quickly used by others to design practical generators.

  3. LiTrack A Fast longitudinal phase space tracking code with graphical user interface

    CERN Document Server

    Emma, Paul

    2005-01-01

    Many linear accelerators, such as linac-based light sources and linear colliders, apply longitudinal phase space manipulations in their design, including electron bunch compression and wakefield-induced energy spread control. Several computer codes handle such issues, but most require detailed information on the transverse focusing lattice. In fact, in most linear accelerators, the transverse distributions do not significantly affect the longitudinal, and can be ignored initially. This allows the use of a fast 2D code to study longitudinal aspects without time-consuming considerations of the transverse focusing. LiTrack is based on a 15-year old code (same name) originally written by one of us (KB), which is now a MATLAB-based code with additional features, such as a graphical user interface and output plotting. The single-bunch tracking includes RF acceleration, bunch compression to 3rd order, geometric and resistive wakefields, aperture limits, synchrotron radiation, and flexible output plotting. The code w...

  4. [Effects of a nutritional intervention in a fast-track program for a colorectal cancer surgery: systematic review].

    Science.gov (United States)

    Wanden-Berghe, Carmina; Sanz-Valero, Javier; Arroyo-Sebastián, Antonio; Cheikh-Moussa, Kamila; Moya-Forcen, Pedro

    2016-07-19

    Introducción: Preoperative nutritional status (NS) has consequences on postoperative (POSTOP) recovery. Our aim was to systematically review the nutritional interventions (NI) in Fast-Track protocols for colorectal cancer surgery and assess morbidity-mortality and patient´s recovery. Systematic review of scientific literature after consulting bibliographic databases: Medline, The Cochrane Library, Scopus, Embase, Web of Science, Institute for Scientific Information, Latin American and Caribbean Health Sciences Literature, The Cumulative Index to Nursing and Allied Health Literature. MeSH Descriptors: "Colorectal Surgery", "Fast-Track", "Perioperative Care", "Nutrition Therapy" and "Enhanced recovery programme". Filters: "Humans", Adult (19+ years) and "Clinical Trial". Variables POSTOP outcomes: bowel recovery (BR), hospital stay (HS), complications and death. Selected studies, 27, had good or excellent methodological quality. From 25 to 597 patients were included. Aged between 16-94 years, men were predominant in 66.6%. NS was evaluated in 13 studies; 7 by Body Mass Index while one by Subjective Global Assessment. One presented POSTOP data. Fast-Track groups had solids, liquids or supplements (SS) in prior 2-8 hours. SS were high in carbohydrates, immune-nutrients and non-residue. Free liquids, solids and SS intake was allowed in POSTOP. Half traditional groups fasted between 3-12 hours and resumed POSTOP food intake progressively. Fast-Track groups had early BR (p Nutritional status must be assessed for a higher acknowledgement of NI impact.

  5. Faraday diamagnetism under slowly oscillating magnetic fields

    Science.gov (United States)

    Kimura, Tsunehisa; Kimura, Fumiko; Kimura, Yosuke

    2018-04-01

    Diamagnetism is a universal phenomenon of materials arising from the orbital motion of electrons bound to atoms, which is commonly known as Langevin diamagnetism. The orbital motion also occurs according to the Faraday's law of induction when the applied magnetic field is oscillating. However, the influence of this dynamic effect on the magnetism of materials has seldom been studied. Here, we propose a new type diamagnetism coined Faraday diamagnetism. The magnitude of this diamagnetism evaluated by an atomic electric circuit model was as large as that of Langevin diamagnetism. The predicted scale of Faraday diamagnetism was supported by experiments.

  6. Fast Track Extubation In Adult Patients On Pump Open Heart Surgery At A Tertiary Care Hospital.

    Science.gov (United States)

    Akhtar, Mohammad Irfan; Sharif, Hasanat; Hamid, Mohammad; Samad, Khalid; Khan, Fazal Hameed

    2016-01-01

    Fast-track cardiac surgery programs have been established as the standard of cardiac surgical care. Studies have shown that early extubation in elective cardiac surgery patients, including coronary and non-coronary open-heart surgery patients does not increase perioperative morbidity and mortality. The objective of this observational study was to determine the success and failure profile of fast track extubation (FTE) practice in adult open-heart surgical patients. The study was conducted at cardiac operating room and Cardiac Intensive Care Unit (CICU) of a tertiary care hospital for a period of nine months, i.e., from Oct 2014 to June-2015. All on pump elective adult cardiac surgery patients including isolated CABG, isolated Valve replacements, combined procedures and aortic root replacements were enrolled in the study. Standardized anesthetic technique was adopted. Surgical and bypass techniques were tailored according to the procedure. Success of Fast track extubation was defined as extubation within 6 hours of arrival in CICU. A total of 290 patients were recruited. The average age of the patients was 56.3±10.5 years. There were 77.6% male and 22.4% female patients. Overall success rate was 51.9% and failure rate was 48.1%. The peri-operative renal insufficiency, cross clamp time and CICU stay (hours) were significantly lower in success group. Re-intubation rate was 0.74%. The perioperative parameters were significantly better in success group and the safety was also demonstrated in the patients who were fast tracked successfully. To implement the practice in its full capacity and benefit, a fast track protocol needs to be devised to standardize the current practices and to disseminate the strategy among junior anaesthesiologists, perfusionists and nursing staff.

  7. Implementing large scale fast track diagnostics in a comprehensive cancer center, pre- and post-measurement data.

    Science.gov (United States)

    van Harten, W H; Goedbloed, N; Boekhout, A H; Heintzbergen, S

    2018-02-07

    In general, patients with a cancer suspicion visit the hospital multiple times before diagnosis is completed. Using various "operations management" techniques a few fast track diagnostic services were implemented in the Netherlands Cancer Institute (NKI) in 2006. Growing patient numbers and increasing process complexity, led to diminished service levels. To decrease the amount of patient visits and to extend these services beyond the (obvious) breast cancer services, fast track diagnostics is now implemented for all 18 cancer types that present with a frequency of minimally one per week. The throughput time (first visit to diagnosis conversation) was measured before, and after implementation of fast track diagnostics. The process was redesigned closely involving the multidisciplinary teams. In an eclectic approach elements from lean management, theory of constraints and mathematical analysis were used to organize slots per tumor type for MRI, CT, PET and echography. A post measurement was performed after 3 and 6 months. In pre measurement access time was calculated to be 10 to 15 workdays, mean throughput time was 6.0 workdays. It proved possible to design the process of 18 tumors as a fast track, of which 7 as "one stop shop" (diagnosis completed in one visit). Involvement of clinical- and board leadership, massive communication efforts and commitment of physicians to reschedule their work proved decisive. After 3 and 6 months of implementation, the mean access time was 8.2 and 8.7 workdays respectively and mean throughput time was 3.4 and 3.3 workdays respectively. Throughput- and access time were considerably shortened after implementation of fast track diagnostics for 18 cancer types. The involvement of physicians in reorganizing their work and rapid responding to their needs during the implementation phase were a crucial success factor.

  8. Faraday effect in hybrid magneto-plasmonic photonic crystals.

    Science.gov (United States)

    Caballero, B; García-Martín, A; Cuevas, J C

    2015-08-24

    We present a theoretical study of the Faraday effect in hybrid magneto-plasmonic crystals that consist of Au-Co-Au perforated membranes with a periodic array of sub-wavelength holes. We show that in these hybrid systems the interplay between the extraordinary optical transmission and the magneto-optical activity leads to a resonant enhancement of the Faraday rotation, as compared to purely ferromagnetic membranes. In particular, we determine the geometrical parameters for which this enhancement is optimized and show that the inclusion of a noble metal like Au dramatically increases the Faraday rotation over a broad bandwidth. Moreover, we show that the analysis of the Faraday rotation in these periodically perforated membranes provides a further insight into the origin of the extraordinary optical transmission.

  9. Fast track diagnosis as a means of reducing diagnostic delay in cancer

    DEFF Research Database (Denmark)

    Larsen, Mette Bach; Vedsted, Peter; Olesen, Frede

    of cancer and expanded services to the general practitioners. Objective: To investigate the diagnostic delay of cancer, patient and provider satisfaction and health economic aspects in two Danish regions with special emphasis on the possible benefits of fast track diagnosis. Methods: The study......Background: Denmark has the highest morbidity and mortality from cancer in Western Europe, and studies suggest that Danish cancer patients are diagnosed at a later stage than patients in the other Nordic countries. To address this issue a Danish hospital has introduced fast track diagnosis...... will be designed as a cross-sectional study with the construction of a clinical database of all incident cancers in two Danish regions within a year (12,000 patients). Data will be collected from general practitioners, patients and national registers. In the first part of the analysis the general variation...

  10. Giant Faraday Rotation in Metal-Fluoride Nanogranular Films.

    Science.gov (United States)

    Kobayashi, N; Ikeda, K; Gu, Bo; Takahashi, S; Masumoto, H; Maekawa, S

    2018-03-21

    Magneto-optical Faraday effect is widely applied in optical devices and is indispensable for optical communications and advanced information technology. However, the bismuth garnet Bi-YIG is only the Faraday material since 1972. Here we introduce (Fe, FeCo)-(Al-,Y-fluoride) nanogranular films exhibiting giant Faraday effect, 40 times larger than Bi-YIG. These films have a nanocomposite structure, in which nanometer-sized Fe, FeCo ferromagnetic granules are dispersed in a Al,Y-fluoride matrix.

  11. Effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation

    Directory of Open Access Journals (Sweden)

    Xing-Tao Cai

    2016-01-01

    Full Text Available Objective: To study the effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation. Methods: Sixty patients with rheumatic heart disease undergoing heart valve surgery were randomly divided into the fast track group (n=30 and conventional group (n=30. Then myocardial injury indicators, mitochondrial oxidative stress indicators, inflammation indicators and nerverelated peptides of both groups were analyzed. Results: cTnI contents at T2-T4 points in time of both groups showed an increasing trend and the increasing trend of fast track group was weaker than that of conventional group; SOD contents as well as mitochondrial tristate respiratory function, respiratory control ratios and phosphorus oxygen ratios in myocardial tissue of fast track group were higher than those of conventional group, and MDA contents was lower than those of conventional group; plasma TNF-α, IL-6, IL-8, NSE, S100β and Aβ contents of fast track group were lower than those of conventional group. Conclusions: Fasttrack cardiac anesthesia can protect myocardial cells, reduce mitochondrial oxidative stress, relieve inflammation and improve nerve function; it is an ideal anesthesia method for cardiac operation.

  12. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective, descrip......OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery......, except for hip pain. The average loss in knee-extension strength after surgery (32%, P = .01) did not correlate with increased thigh circumference (6%, P

  13. Faraday polarization fluctuations of satellite beacon signals

    Science.gov (United States)

    Lee, M. C.; Klobuchar, J. A.

    1988-01-01

    The anisotropic effects of random density irregularities in causing Faraday polarization fluctuations of VHF radio signals are examined, taking both rod-like and sheet-like irregularities into consideration. It is found that the variance of Faraday polarization fluctuations depends on the ratio of perpendicular to parallel correlation lengths. The anisotropic effect of rod-like ionospheric irregularities are shown to be most appreciable for longitudinal propagation. The anisotropic effect of sheet-like ionospheric irregularities, however, is not strongly dependent on the radio propagation angle. During transionospheric propagation at large angles with respect to the geomagnetic field, sheet-like irregularities may cause greater Faraday polarization fluctuations than rod-like irregularities.

  14. Fabry-Perot enhanced Faraday rotation in graphene.

    Science.gov (United States)

    Ubrig, Nicolas; Crassee, Iris; Levallois, Julien; Nedoliuk, Ievgeniia O; Fromm, Felix; Kaiser, Michl; Seyller, Thomas; Kuzmenko, Alexey B

    2013-10-21

    We demonstrate that giant Faraday rotation in graphene in the terahertz range due to the cyclotron resonance is further increased by constructive Fabry-Perot interference in the supporting substrate. Simultaneously, an enhanced total transmission is achieved, making this effect doubly advantageous for graphene-based magneto-optical applications. As an example, we present far-infrared spectra of epitaxial multilayer graphene grown on the C-face of 6H-SiC, where the interference fringes are spectrally resolved and a Faraday rotation up to 0.15 radians (9°) is attained. Further, we discuss and compare other ways to increase the Faraday rotation using the principle of an optical cavity.

  15. Faraday wave lattice as an elastic metamaterial.

    Science.gov (United States)

    Domino, L; Tarpin, M; Patinet, S; Eddi, A

    2016-05-01

    Metamaterials enable the emergence of novel physical properties due to the existence of an underlying subwavelength structure. Here, we use the Faraday instability to shape the fluid-air interface with a regular pattern. This pattern undergoes an oscillating secondary instability and exhibits spontaneous vibrations that are analogous to transverse elastic waves. By locally forcing these waves, we fully characterize their dispersion relation and show that a Faraday pattern presents an effective shear elasticity. We propose a physical mechanism combining surface tension with the Faraday structured interface that quantitatively predicts the elastic wave phase speed, revealing that the liquid interface behaves as an elastic metamaterial.

  16. Modified Faraday cup

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.; O'Brien, Dennis W.

    1996-01-01

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0.degree. to 360.degree. and the waveforms are recorded by a digitizing storage oscilloscope. Two-din-tensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment.

  17. The Faraday effect in two-dimensional magneto-photonic crystals

    International Nuclear Information System (INIS)

    Merzlikin, A.M.; Vinogradov, A.P.; Inoue, M.; Khanikaev, A.B.; Granovsky, A.B.

    2006-01-01

    The necessary conditions for the observation of the Faraday effect in 2D magneto-photonic crystals are discussed. It is found. that the Faraday effect may be observed in the directions where any couple of the wave vectors of the harmonics consisting the Bloch waves of TE and TM solutions in zero magnetic field are identical. This direction corresponds neither to Faraday nor to Voigt geometry

  18. The Faraday effect in two-dimensional magneto-photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Merzlikin, A.M. [Institute for Theoretical and Applied Electromagnetism, OIVT, Russian Academy of Sciences, Izhorskay 13/19, Moscow 125412 (Russian Federation)]. E-mail: merzlikin_a@mail.ru; Vinogradov, A.P. [Institute for Theoretical and Applied Electromagnetism, OIVT, Russian Academy of Sciences, Izhorskay 13/19, Moscow 125412 (Russian Federation); Inoue, M. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, 1-1, Hibari-Ga-Oka, Tempaku, Toyohashi 441-8580 (Japan); Khanikaev, A.B. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, 1-1, Hibari-Ga-Oka, Tempaku, Toyohashi 441-8580 (Japan); Granovsky, A.B. [Faculty of Physics, Lomonosov Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation)

    2006-05-15

    The necessary conditions for the observation of the Faraday effect in 2D magneto-photonic crystals are discussed. It is found. that the Faraday effect may be observed in the directions where any couple of the wave vectors of the harmonics consisting the Bloch waves of TE and TM solutions in zero magnetic field are identical. This direction corresponds neither to Faraday nor to Voigt geometry.

  19. Anesthetic and adjunctive drugs for fast-track surgery.

    Science.gov (United States)

    Baldini, G; Carli, F

    2009-08-01

    With the changes in health care dictated by economic pressure, there has been a realization that hospital stay could be shortened without compromising quality of care. Advances in surgical technology and anesthetic drugs have made an impact in the way perioperative care is delivered with some emphasis on multidisciplinary approach. From the expansion of ambulatory care, lessons were learnt how to apply same concepts to major surgery with the understanding that interventions to attenuate the surgical stress would facilitate the return to "baseline". Beside minimal invasive approach to surgery, anesthesia interventions are arranged with the intent to decrease the negative effects of surgical stress and pain, to minimize the side effects of drugs and at the same time to facilitate the recuperation which follows after surgery. Fast-track or accelerated care encompasses many aspects of anesthesia care, not only preoperative preparation and prehabilitation, but intraoperative attenuation of surgical stress and postoperative rehabilitation. The anesthesiologist is part of this team with the specific mission to use medications and techniques which have the least side effects on organ functions, provide analgesia which in turn facilitates the intake of food and mobilization out of bed. This chapter has been conceived with the intention to direct the clinician towards procedure-specific protocols where the choice of medications and techniques is based on published evidence. The success of implementing fast-track depends more on dynamic harmony amongst the various participants (surgeons, anesthesiologists, nurses, nutrtionists, physiotherapists) than on reaching an optimum level of excellence at each separate organization level.

  20. Electromagnetic analysis of the Faraday shield of the EAST ICRF antenna

    International Nuclear Information System (INIS)

    Yang Qingxi; Song Yuntao; Wu Songtao; Zhao Yanping

    2011-01-01

    Faraday shield is one of the important components of ICRF antenna for EAST. In view of the structural safety of the Faraday shield, the electromagnetic and structural analyses for the Faraday shield have been carried out by applying the finite element method and the formulas under the cases of plasma disruption and vertical displacement event (VDE). Results of the electromagnetic forces, the stresses distribution as well as the deformation in the Faraday shield have been obtained under the two cases. They meet the design requirements and provide the theoretical basis for the structural safety evaluation of the Faraday shield. (authors)

  1. Theory of the inverse Faraday effect in metals

    International Nuclear Information System (INIS)

    Hertel, Riccardo

    2006-01-01

    An analytic expression is given for the inverse Faraday effect, i.e., for the magnetization occurring in a transparent medium exposed to a circularly polarized high-frequency electromagnetic wave. Using a microscopic approach based on the Drude approximation of a free-electron gas, the magnetization of the medium due to the inverse Faraday effect is identified as the result of microscopic solenoidal currents generated by the electromagnetic wave. In contrast to the better known phenomenological derivation, this microscopic treatment provides important information on the frequency dependence of the inverse Faraday effect

  2. The hyperfine Paschen–Back Faraday effect

    International Nuclear Information System (INIS)

    Zentile, Mark A; Andrews, Rebecca; Weller, Lee; Adams, Charles S; Hughes, Ifan G; Knappe, Svenja

    2014-01-01

    We investigate experimentally and theoretically the Faraday effect in an atomic medium in the hyperfine Paschen–Back regime, where the Zeeman interaction is larger than the hyperfine splitting. We use a small permanent magnet and a micro-fabricated vapour cell, giving magnetic fields of the order of a tesla. We show that for low absorption and small rotation angles, the refractive index is well approximated by the Faraday rotation signal, giving a simple way to measure the atomic refractive index. Fitting to the atomic spectra, we achieve magnetic field sensitivity at the 10 −4 level. Finally we note that the Faraday signal shows zero crossings which can be used as temperature insensitive error signals for laser frequency stabilization at large detuning. The theoretical sensitivity for 87 Rb is found to be ∼40 kHz °C −1 . (paper)

  3. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking

    DEFF Research Database (Denmark)

    Ravkilde, Thomas; Keall, Paul J.; Grau, Cai

    2014-01-01

    of the algorithm for reconstruction of dose and motion-induced dose errors throughout the tracking and non-tracking beam deliveries was quantified. Doses were reconstructed with a mean dose difference relative to the measurements of -0.5% (5.5% standard deviation) for cumulative dose. More importantly, the root...... validate a simple model for fast motion-including dose error reconstruction applicable to intrafractional QA of MLC tracking treatments of moving targets. MLC tracking experiments were performed on a standard linear accelerator with prototype MLC tracking software guided by an electromagnetic transponder......-mean-square deviation between reconstructed and measured motion-induced 3%/3 mm γ failure rates (dose error) was 2.6%. The mean computation time for each calculation of dose and dose error was 295 ms. The motion-including dose reconstruction allows accurate temporal and spatial pinpointing of errors in absorbed dose...

  4. Faraday scaling and the Bicep2 observations

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    As repeatedly speculated in the past, the linear polarization of the Cosmic Microwave Background can be rotated via the Faraday effect. An economic explanation of the recent Bicep2 observations, not relying on long-wavelength tensor modes of the geometry, would stipulate that the detected B mode comes exclusively from a Faraday rotated E mode polarization. We show hereunder that this interpretation is ruled out by the existing upper limits on the B mode polarization obtained by independent experiments at observational frequencies much lower than the operating frequency of the Bicep2 experiment. We then derive the fraction of the observed B mode polarization ascribable to the Faraday effect and suggest a dedicated experimental strategy for its detection.

  5. Helios-1 Faraday rotation experiment - Results and interpretations of the solar occultations in 1975

    Science.gov (United States)

    Volland, H.; Bird, M. K.; Levy, G. S.; Stelzried, C. T.; Seidel, B. L.

    1977-01-01

    The first of two solar occultations of the satellite Helios-1 in 1975 occurred in April when the satellite's ray path approached the west limb of the sun to a minimum distance of 1.63 solar radii. The second occultation took place in late August/early September when Helios-1 was totally eclipsed by the photosphere. Measurements of the polarization angle of the linearly polarized telemetry signal were performed with automatic tracking polarimeters at the 64 m Goldstone Tracking Station in California and also at the 100 m radio telescope in Effelsberg, West Germany. The coronal Faraday rotation as a function of the solar offset for both occultations is shown in graphs. The theoretical significance of the observations is investigated.

  6. Readmission rates after a planned hospital stay of 2 versus 3 days in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Andersen, Jens; Hjort-Jakobsen, Dorthe; Christiansen, P. S.

    2007-01-01

    BACKGROUND: Initial programmes of fast-track open colonic surgery with a planned 2-day postoperative hospital stay have had a high readmission rate (about 20 per cent). The aim of this large, consecutive series was to compare readmission rates after a fast-track open colonic surgery programme....... There was no difference in type and incidence of morbidity between the two periods. CONCLUSION: Readmission after fast-track open colonic resection was reduced by planning discharge 3 instead of 2 days after surgery, with the same discharge criteria. Copyright (c) 2007 British Journal of Surgery Society Ltd. Published...... from August 2004. All patients were examined 8 and 30 days after surgery. RESULTS: Readmission rates fell from 20.1 per cent in 408 patients with a planned 2-day hospital stay (period 1) to 11.3 per cent in 133 patients with a planned 3-day hospital stay (period 2) (P

  7. Families' Divided: The place of the Family in Zimbabwe's Fast Track ...

    African Journals Online (AJOL)

    The political history and the political economy continue to mould the quality of life for most families in significant ways. Human beings have always lived in families from the beginning of time. The family is a pillar of society as it influences the way society is structured, organized and functions, yet the Fast Track Land Reform ...

  8. When is it optimal to delegate: the theory of fast-track authority

    Czech Academy of Sciences Publication Activity Database

    Celik, Levent; Karabay, Bilgehan; McLaren, J.

    2015-01-01

    Roč. 7, č. 3 (2015), s. 347-389 ISSN 1945-7669 R&D Projects: GA ČR(CZ) GAP402/12/0666 Institutional support: PRVOUK-P23 Keywords : fast-track authority * free trade * protectionist rents Subject RIV: AH - Economics Impact factor: 1.359, year: 2015

  9. How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?

    Science.gov (United States)

    Sorensen, Lucy C; Dodge, Kenneth A

    2016-01-01

    Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how-that is, through which developmental pathways-these interventions work. This study assesses mechanisms by which the Fast Track project (n = 891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and general and mental health service utilization in adolescence through young adulthood (ages 12-20). A decomposition of treatment effects indicates that about a third of Fast Track's impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6-11), such as prosocial behavior, emotion regulation, and problem solving. These skills proved less valuable for the prevention of general and mental health problems. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  10. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  11. The Faraday effect of natural and artificial ferritins.

    Science.gov (United States)

    Koralewski, M; Kłos, J W; Baranowski, M; Mitróová, Z; Kopčanský, P; Melníková, L; Okuda, M; Schwarzacher, W

    2012-09-07

    Measurements of the Faraday rotation at room temperature over the light wavelength range of 300-680 nm for horse spleen ferritin (HSF), magnetoferritin with different loading factors (LFs) and nanoscale magnetite and Fe(2)O(3) suspensions are reported. The Faraday rotation and the magnetization of the materials studied present similar magnetic field dependences and are characteristic of a superparamagnetic system. The dependence of the Faraday rotation on the magnetic field is described, excluding HSF and Fe(2)O(3), by a Langevin function with a log-normal distribution of the particle size allowing the core diameters of the substances studied to be calculated. It was found that the specific Verdet constant depends linearly on the LF. Differences in the Faraday rotation spectra and their magnetic field dependences allow discrimination between magnetoferritin with maghemite and magnetite cores which can be very useful in biomedicine.

  12. The Faraday effect of natural and artificial ferritins

    International Nuclear Information System (INIS)

    Koralewski, M; Kłos, J W; Baranowski, M; Mitróová, Z; Kopčanský, P; Melníková, L; Okuda, M; Schwarzacher, W

    2012-01-01

    Measurements of the Faraday rotation at room temperature over the light wavelength range of 300–680 nm for horse spleen ferritin (HSF), magnetoferritin with different loading factors (LFs) and nanoscale magnetite and Fe 2 O 3 suspensions are reported. The Faraday rotation and the magnetization of the materials studied present similar magnetic field dependences and are characteristic of a superparamagnetic system. The dependence of the Faraday rotation on the magnetic field is described, excluding HSF and Fe 2 O 3 , by a Langevin function with a log-normal distribution of the particle size allowing the core diameters of the substances studied to be calculated. It was found that the specific Verdet constant depends linearly on the LF. Differences in the Faraday rotation spectra and their magnetic field dependences allow discrimination between magnetoferritin with maghemite and magnetite cores which can be very useful in biomedicine. (paper)

  13. Evaluation of ion collection area in Faraday probes.

    Science.gov (United States)

    Brown, Daniel L; Gallimore, Alec D

    2010-06-01

    A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.

  14. Evaluation of ion collection area in Faraday probes

    International Nuclear Information System (INIS)

    Brown, Daniel L.; Gallimore, Alec D.

    2010-01-01

    A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.

  15. Mode-locking via dissipative Faraday instability.

    Science.gov (United States)

    Tarasov, Nikita; Perego, Auro M; Churkin, Dmitry V; Staliunas, Kestutis; Turitsyn, Sergei K

    2016-08-09

    Emergence of coherent structures and patterns at the nonlinear stage of modulation instability of a uniform state is an inherent feature of many biological, physical and engineering systems. There are several well-studied classical modulation instabilities, such as Benjamin-Feir, Turing and Faraday instability, which play a critical role in the self-organization of energy and matter in non-equilibrium physical, chemical and biological systems. Here we experimentally demonstrate the dissipative Faraday instability induced by spatially periodic zig-zag modulation of a dissipative parameter of the system-spectrally dependent losses-achieving generation of temporal patterns and high-harmonic mode-locking in a fibre laser. We demonstrate features of this instability that distinguish it from both the Benjamin-Feir and the purely dispersive Faraday instability. Our results open the possibilities for new designs of mode-locked lasers and can be extended to other fields of physics and engineering.

  16. Faraday waves under time-reversed excitation.

    Science.gov (United States)

    Pietschmann, Dirk; Stannarius, Ralf; Wagner, Christian; John, Thomas

    2013-03-01

    Do parametrically driven systems distinguish periodic excitations that are time mirrors of each other? Faraday waves in a Newtonian fluid are studied under excitation with superimposed harmonic wave forms. We demonstrate that the threshold parameters for the stability of the ground state are insensitive to a time inversion of the driving function. This is a peculiarity of some dynamic systems. The Faraday system shares this property with standard electroconvection in nematic liquid crystals [J. Heuer et al., Phys. Rev. E 78, 036218 (2008)]. In general, time inversion of the excitation affects the asymptotic stability of a parametrically driven system, even when it is described by linear ordinary differential equations. Obviously, the observed symmetry has to be attributed to the particular structure of the underlying differential equation system. The pattern selection of the Faraday waves above threshold, on the other hand, discriminates between time-mirrored excitation functions.

  17. Influencing Factor of Postoperation Fast-track Recovery and in Hospital Cost after Lobctomy for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Jianhua SU

    2014-07-01

    Full Text Available Background and objective It is unknown that the postoperation fast-track recovery and in hospital cost of the lobectomy in lung cancer, we explored the influencing factor of postoperative fast-track recovery and in hospital cost after undergoing lobectomy for lung cancer. Methods We retrospectively reviewed the medical records of all patients (n=176 who underwent lobectomy for lung cancer between January 2010 and November 2011 by a thoracic surgeon. Results The hospital costs of video-assisted thoracic surgery (VATS lobectomy (47,308.21 ¥ is significantly higher than open lobectomy (45,664.31 ¥(P=0.007. The hospital costs of body mass index (BMI ≥ 24 kg/m2 (51,186.99 ¥ is significantly higher than BMI < 24 kg/m2 (41,701.64 ¥(P=0.032. The hospital stay of VATS lobectomy (5.70 d is significantly less than open lobectomy (7.10 d(P<0.001. Conclusion These findings indicate that preoperative pulmonary rehabilitation and VATS lobectomy is contributed to fast-track recovery for patients who undergo lobectomy, but increase the hospital costs.

  18. Development of Faraday rotators for high power glass laser systems

    International Nuclear Information System (INIS)

    Yoshida, Kunio; Kato, Yoshiaki; Yamanaka, Chiyoe.

    1980-01-01

    As a new approach to nuclear fusion, laser-induced fusion has been recently highlighted. It is no exaggeration to say that the future success of this technique depends on the development of high power laser as the energy driver. Faraday rotators are used as photo-diodes to prevent amplifiers and oscillator assemblies from the possibility to be broken by reversely transmitting light. The authors were able to increase the isolation ratio by about 10 times as compared with conventional one by employing the large performance index, disc type Faraday glass, FR-5. In this paper, first, Faraday glasses which are the composing element of Faraday rotators and the optical characteristics of dielectric thin-film polarizers are described, and next, the design of a magnetic coil and its resulting coil characteristics are reported. Then the dominant causes limiting the isolation ratio of Faraday rotators are investigated, and it is clarified that the residual strain in Faraday glasses and the non-uniformity of magnetic field affect predominantly. The measured results are as follows: The magnetic flux densities required to rotate by 45 deg the polarizing plane of the light transmitted through the Faraday rotators A and B are both 27 kG; and the isolation ratios over the whole effective plane are 36 and 32 dB, respectively. (Wakatsuki, Y.)

  19. Combline antennas for launching traveling fast waves

    International Nuclear Information System (INIS)

    Moeller, C.P.; Gould, R.W.; Phelps, D.A.; Pinsker, R.I.

    1994-01-01

    The combline structure shows promise for launching traveling fast magnetosonic waves with adjustable n parallel (3 ≤ n parallel ≤ 6) for current drive. In this paper, the dispersion and damping properties of the combline antenna with and without a Faraday shield are given. The addition of a Faraday shield which eliminates the electrostatic coupling between current straps as well as between the straps and plasma offers the advantage of eliminating the need for the lumped capacitors which are otherwise required with this structure. The results of vacuum dispersion and damping measurements on a low power model antenna are also given. (author)

  20. Indirect Effects of the Fast Track Intervention on Conduct Disorder Symptoms and Callous-Unemotional Traits: Distinct Pathways Involving Discipline and Warmth.

    Science.gov (United States)

    Pasalich, Dave S; Witkiewitz, Katie; McMahon, Robert J; Pinderhughes, Ellen E

    2016-04-01

    Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 to 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children's CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively.

  1. Rethinking Faraday's Law for Teaching Motional Electromotive Force

    Science.gov (United States)

    Zuza, Kristina; Guisasola, Jenaro; Michelini, Marisa; Santi, Lorenzo

    2012-01-01

    This study shows physicists' discussions on the meaning of Faraday's law where situations involving extended conductors or moving contact points are particularly troublesome. We raise questions to test students' difficulties in applying Faraday's law in motional electromotive force phenomena. We suggest the benefit of analysing these phenomena…

  2. Cognitive dysfunction after fast-track hip and knee replacement.

    Science.gov (United States)

    Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben; Solgaard, Søren; Soballe, Kjeld; Rasmussen, Lars Simon

    2014-05-01

    Postoperative cognitive dysfunction (POCD) is reported to occur after major surgery in as many as 20% of patients, elderly patients may especially experience problems in the weeks and months after surgery. Recent studies vary greatly in methods of evaluation and diagnosis of POCD, and the pathogenic mechanisms are still unclear. We evaluated a large uniform cohort of elderly patients in a standardized approach, after major joint replacement surgery (total hip and knee replacement). Patients were in an optimized perioperative approach (fast track) with multimodal opioid-sparing analgesia, early mobilization, and short length of stay (LOS ≤3 days) and discharged to home. In a prospective multicenter study, we included 225 patients aged ≥60 years undergoing well-defined fast-track total hip or total knee replacement. Patients had neuropsychological testing preoperatively and 1 to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). Median LOS was 2 days (interquartile range 2-3). The incidence of POCD at 1 to 2 weeks was 9.1% (95% confidence interval [CI], 5.4%-13.1%) and 8.0% (95% CI, 4.5%-12.0%) at 3 months. There was no statistically significant difference between patients with and without early POCD, regarding pain, opioid use, sleep quality, or C-reactive protein response, although the CIs were wide. Patients with early POCD had a higher Mini Mental State Examination score preoperatively (difference in medians 0.5 [95% CI, -1.0% to 0.0%]; P = 0.034). If there was an association between early POCD and late POCD, the sample size was unfortunately too small to verify this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). The incidence of POCD early after total hip and knee replacement

  3. Interactive and automated systems for nuclear track measurements with applications to fast neutron dosimetry

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; McNeece, J.P.; Preston, C.C.; Ruddy, F.H.

    1983-12-01

    Interactive and automatic track measuring systems have been developed primarily for fast neutron dosimetry in and around reactors. The interactive system is used for proton recoil measurements in nuclear research emulsions and the automatic systems for counting fission fragment tracks in Muscovite mica. The status of these systems, along with illustrative applications, are presented, particularly with regard to their relationship to neutron personnel dosimetry. 16 references, 12 figures

  4. The Faraday rotation experiment. [solar corona

    Science.gov (United States)

    Volland, H.; Levy, G. S.; Bird, M. K.; Stelzried, C. T.; Seidel, B. L.

    1984-01-01

    The magnetized plasma of the solar corona was remotely sounded using the Faraday rotation effect. The solar magnetic field together with the electrons of the coronal plasma cause a measurable Faraday rotation effect, since the radio waves of Helios are linearly polarized. The measurement is performed at the ground stations. Alfven waves traveling from the Sun's surface through the corona into interplanetary space are observed. Helios 2 signals penetrating through a region where coronal mass is ejected show wavelike structures.

  5. Fast Poisson Solvers for Self-Consistent Beam-Beam and Space-Charge Field Computation in Multiparticle Tracking Simulations

    CERN Document Server

    Florio, Adrien; Pieloni, Tatiana; CERN. Geneva. ATS Department

    2015-01-01

    We present two different approaches to solve the 2-dimensional electrostatic problem with open boundary conditions to be used in fast tracking codes for beam-beam and space charge simulations in high energy accelerators. We compare a fast multipoles method with a hybrid Poisson solver based on the fast Fourier transform and finite differences in polar coordinates. We show that the latter outperforms the first in terms of execution time and precision, allowing for a reduction of the noise in the tracking simulation. Furthermore the new algorithm is shown to scale linearly on parallel architectures with shared memory. We conclude by effectively replacing the HFMM by the new Poisson solver in the COMBI code.

  6. Faraday rotation due to excitation of magnetoplasmons in graphene microribbons.

    Science.gov (United States)

    Tymchenko, Mykhailo; Nikitin, Alexey Yu; Martín-Moreno, Luis

    2013-11-26

    A single graphene sheet, when subjected to a perpendicular static magnetic field, provides a Faraday rotation that, per atomic layer, greatly surpasses that of any other known material. In continuous graphene, Faraday rotation originates from the cyclotron resonance of massless carriers, which allows dynamical tuning through either external electrostatic or magneto-static setting. Furthermore, the rotation direction can be controlled by changing the sign of the carriers in graphene, which can be done by means of an external electric field. However, despite these tuning possibilities, the requirement of large magnetic fields hinders the application of the Faraday effect in real devices, especially for frequencies higher than a few terahertz. In this work we demonstrate that large Faraday rotation can be achieved in arrays of graphene microribbons, through the excitation of the magnetoplasmons of individual ribbons, at larger frequencies than those dictated by the cyclotron resonance. In this way, for a given magnetic field and chemical potential, structuring graphene periodically can produce large Faraday rotation at larger frequencies than what would occur in a continuous graphene sheet. Alternatively, at a given frequency, graphene ribbons produce large Faraday rotation at much smaller magnetic fields than in continuous graphene.

  7. Fast regional readout CMOS Image Sensor for dynamic MLC tracking

    Science.gov (United States)

    Zin, H.; Harris, E.; Osmond, J.; Evans, P.

    2014-03-01

    Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ~400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.

  8. Fast regional readout CMOS image sensor for dynamic MLC tracking

    International Nuclear Information System (INIS)

    Zin, H; Harris, E; Osmond, J; Evans, P

    2014-01-01

    Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ∼400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.

  9. The Flexible Faraday Cage

    Science.gov (United States)

    Gluck, Paul

    2004-03-01

    The Faraday ice-pail experiment is performed when studying the distribution of charges in conductors: Inside a hollow conductor the net charge is zero, and any excess charge resides on the outside surface.

  10. Postoperative Urinary Catheterization Thresholds of 500 versus 800 ml after Fast-track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars Stryhn; Hornum, Ulla Marianne; Troldborg, C.

    2016-01-01

    arthroplasty (THA) and total knee arthroplasty (TKA). METHODS: This was a randomized, controlled, open-label trial that included patients greater than or equal to 18 yr who underwent THA or TKA in three Danish, fast-track, orthopedic departments. Consenting patients were eligible if they were cooperative......BACKGROUND: No evidence-based threshold exists for postoperative urinary bladder catheterization. The authors hypothesized that a catheterization threshold of 800 ml was superior to 500 ml in reducing postoperative urinary catheterization and urological complications after fast-track total hip...

  11. Competing Turing and Faraday Instabilities in Longitudinally Modulated Passive Resonators.

    Science.gov (United States)

    Copie, François; Conforti, Matteo; Kudlinski, Alexandre; Mussot, Arnaud; Trillo, Stefano

    2016-04-08

    We experimentally investigate the interplay of Turing (modulational) and Faraday (parametric) instabilities in a bistable passive nonlinear resonator. The Faraday branch is induced via parametric resonance owing to a periodic modulation of the resonator dispersion. We show that the bistable switching dynamics is dramatically affected by the competition between the two instability mechanisms, which dictates two completely novel scenarios. At low detunings from resonance, switching occurs between the stable stationary lower branch and the Faraday-unstable upper branch, whereas at high detunings we observe the crossover between the Turing and Faraday periodic structures. The results are well explained in terms of the universal Lugiato-Lefever model.

  12. A Midsize Tokamak As Fast Track To Burning Plasmas

    International Nuclear Information System (INIS)

    Mazzucato, E.

    2010-01-01

    This paper presents a midsize tokamak as a fast track to the investigation of burning plasmas. It is shown that it could reach large values of energy gain ((ge) 10) with only a modest improvement in confinement over the scaling that was used for designing the International Thermonuclear Experimental Reactor (ITER). This could be achieved by operating in a low plasma recycling regime that experiments indicate can lead to improved plasma confinement. The possibility of reaching the necessary conditions of low recycling using a more efficient magnetic divertor than those of present tokamaks is discussed.

  13. FAST TRACK SURGERY IN TOTAL KNEE ARTHROPLASTY - A REVIEW.

    Directory of Open Access Journals (Sweden)

    Pencho Kosev

    2015-08-01

    Full Text Available The number of orthopedic surgeons who are convinced in the need for significant changes in planned total knee arthroplasty (TKA is increasing slowly and steadily. A new approach to pain control has been developed over the past 10-15 years, and the introduction of techniques to reduce perioperative stress, and the use of minimally invasive surgical techniques can help limit postoperative complications and shorten recovery time. This type of optimization is regarded as Fast-track Care program, where improved healing process is particularly useful to comorbid patients.

  14. Variation in 'fast-track' referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites.

    Science.gov (United States)

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    In England, 'fast-track' (also known as 'two-week wait') general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. We examined data from 669 220 patients with 35 cancers diagnosed in 2006-2010 following either fast-track or 'routine' primary-to-secondary care referrals using 'Routes to Diagnosis' data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for 'alarm' symptoms are needed to improve diagnostic timeliness.

  15. Study of the Vertical Magnetic Field in Face-on Galaxies Using Faraday Tomography

    Science.gov (United States)

    Ideguchi, Shinsuke; Tashiro, Yuichi; Akahori, Takuya; Takahashi, Keitaro; Ryu, Dongsu

    2017-07-01

    Faraday tomography allows astronomers to probe the distribution of the magnetic field along the line of sight (LOS), but that can be achieved only after the Faraday spectrum is interpreted. However, the interpretation is not straightforward, mainly because the Faraday spectrum is complicated due to a turbulent magnetic field; it ruins the one-to-one relation between the Faraday depth and the physical depth, and appears as many small-scale features in the Faraday spectrum. In this paper, by employing “simple toy models” for the magnetic field, we describe numerically as well as analytically the characteristic properties of the Faraday spectrum. We show that the Faraday spectrum along “multiple LOSs” can be used to extract the global properties of the magnetic field. Specifically, considering face-on spiral galaxies and modeling turbulent magnetic field as a random field with a single coherence length, we numerically calculate the Faraday spectrum along a number of LOSs and its shape-characterizing parameters, that is, the moments. When multiple LOSs cover a region of ≳(10 coherence length)2, the shape of the Faraday spectrum becomes smooth and the shape-characterizing parameters are well specified. With the Faraday spectrum constructed as a sum of Gaussian functions with different means and variances, we analytically show that the parameters are expressed in terms of the regular and turbulent components of the LOS magnetic field and the coherence length. We also consider the turbulent magnetic field modeled with a power-law spectrum, and study how the magnetic field is revealed in the Faraday spectrum. Our work suggests a way to obtain information on the magnetic field from a Faraday tomography study.

  16. Study of the Vertical Magnetic Field in Face-on Galaxies Using Faraday Tomography

    International Nuclear Information System (INIS)

    Ideguchi, Shinsuke; Ryu, Dongsu; Tashiro, Yuichi; Takahashi, Keitaro; Akahori, Takuya

    2017-01-01

    Faraday tomography allows astronomers to probe the distribution of the magnetic field along the line of sight (LOS), but that can be achieved only after the Faraday spectrum is interpreted. However, the interpretation is not straightforward, mainly because the Faraday spectrum is complicated due to a turbulent magnetic field; it ruins the one-to-one relation between the Faraday depth and the physical depth, and appears as many small-scale features in the Faraday spectrum. In this paper, by employing “simple toy models” for the magnetic field, we describe numerically as well as analytically the characteristic properties of the Faraday spectrum. We show that the Faraday spectrum along “multiple LOSs” can be used to extract the global properties of the magnetic field. Specifically, considering face-on spiral galaxies and modeling turbulent magnetic field as a random field with a single coherence length, we numerically calculate the Faraday spectrum along a number of LOSs and its shape-characterizing parameters, that is, the moments. When multiple LOSs cover a region of ≳(10 coherence length) 2 , the shape of the Faraday spectrum becomes smooth and the shape-characterizing parameters are well specified. With the Faraday spectrum constructed as a sum of Gaussian functions with different means and variances, we analytically show that the parameters are expressed in terms of the regular and turbulent components of the LOS magnetic field and the coherence length. We also consider the turbulent magnetic field modeled with a power-law spectrum, and study how the magnetic field is revealed in the Faraday spectrum. Our work suggests a way to obtain information on the magnetic field from a Faraday tomography study.

  17. Most patients regain prefracture basic mobility after hip fracture surgery in a fast-track programme

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Kehlet, Henrik

    2012-01-01

    Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity of the p......Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity...... of the preliminary prefracture New Mobility Score (NMS), age and fracture type as independent predictors of in-hospital outcome after hip fracture surgery....

  18. A Left-Hand Rule for Faraday's Law

    Science.gov (United States)

    Salu, Yehuda

    2014-01-01

    A left-hand rule for Faraday's law is presented here. This rule provides a simple and quick way of finding directional relationships between variables of Faraday's law without using Lenz's rule.

  19. Generalized Faraday law derived from classical forces in a rotating frame

    International Nuclear Information System (INIS)

    Choi, Taeseung

    2010-01-01

    We show that an additional spin-dependent classical force due to the rotation of an electron spin's rest frame is essential to derive a spin-Faraday law that has the same form as the usual Faraday law. We show that the contribution of the additional spin-dependent force to the spin-Faraday law is the same as the time derivative of the spin geometric phase. With this observations, the spin-Faraday law is generalized to include both an Aharonov-Casher (AC) effect and a scalar AC effect in a unified manner.

  20. LiTrack: A Fast Longitudinal Phase Space Tracking Code with Graphical User Interface

    International Nuclear Information System (INIS)

    Bane, K.L.F.

    2005-01-01

    Linac-based light sources and linear colliders typically apply longitudinal phase space manipulations in their design, including electron bunch compression and wakefield-induced energy spread control. Several computer codes handle such issues, but most also require detailed information on the transverse focusing lattice. In fact, in most linear accelerators, the transverse distributions do not significantly affect the longitudinal, and can be ignored initially. This allows the use of a fast 2D code to study longitudinal aspects without time-consuming considerations of the transverse focusing. LiTrack is based on a 15-year old code (same name) originally written by one of us (KB), which is now a Matlab [1] code with additional features, such as graphical user interface, prompt output plotting, and functional call within a script. This single-bunch tracking code includes RF acceleration, bunch compression to 3rd order, geometric and resistive short-range wakefields, aperture limits, synchrotron radiation, and flexible output plotting. The code was used to design both the LCLS [2] and the SPPS [3] projects at SLAC and typically runs 10 5 particles in < 1 minute. We describe the features, show some examples, and provide free access to the code

  1. Safeguarding Self-Governance: A Grounded Theory of Older Patients’ Pattern of Behavior in Relation to their Relatives in Fast-track Programs

    DEFF Research Database (Denmark)

    Berthelsen, Connie B.; Frederiksen, Kirsten; Lindhardt Damsgaard, Tove

    2014-01-01

    Abstract The aim of this study was to generate a grounded theory of older patients’ pattern of behavior in relation to their relatives’ involvement in fast-track programs during total joint replacement. Sixteen patients were recruited in orthopedic wards. Data collection included 11 interviews......, shielding, distancing, and masking. Keywords: Fast-track program, grounded theory, older patients, relatives, total joint replacement.......-governance emerged in the analysis as the core category of our theory and pattern of behavior of the older patients in relation to their relatives. The older patients’ main concern was to complete the fast-track program while maintaining autonomy, which they resolved through four strategies of actions: embracing...

  2. The RSC Faraday prize lecture of 1989 on platinum.

    Science.gov (United States)

    Thomas, John Meurig

    2017-08-25

    In 1861, Michael Faraday gave one of his last Friday Evening Discourses at the Royal Institution of Great Britain, London, on platinum, which he described as "this beautiful, magnificent and valuable metal". More than a hundred and twenty years later (in 1989), the author re-enacted, at the Royal Institution, many of the demonstrations that Faraday carried out in his memorable Discourse. This article outlines many of Faraday's views on, and experiments with, platinum. It also describes the continuing importance and utilization of platinum, both as perceived in 1989 and from present perspectives.

  3. Joule loss on a Faraday shield of JT-60 ICRF test antenna

    International Nuclear Information System (INIS)

    Fujii, Tsuneyuki; Saigusa, Mikio; Ikeda, Yoshitaka; Kimura, Haruyuki; Hirashima, Teruhisa; Uehara, Munenori.

    1988-01-01

    Joule loss on a Faraday shield of JT-60 ICRF test antenna with a conductive casing is investigated at the frequency range of 120 MHz. The magnetic field radiated from the antenna is measured by three-dimensionally scanning an rf probe both inside and outside the antenna casing. The magnetic field perpendicular to the Faraday shield, B x , is found to be the largest component near the Faraday shield. It consequently gives the major part of the joule loss on the Faraday shield. The temperature distribution of the Faraday shield due to joule loss is measured directly with a thermocamera. It is confirmed that the area of the high temperature rise is consistent with the peak positions of the B x field. Faraday shield resistance which is estimated from power measurements agrees with the theoretical value. (author)

  4. Surgical Stress Response and Postoperative Immune Function After Laparoscopy or Open Surgery With Fast Track or Standard Perioperative Care A Randomized Trial

    NARCIS (Netherlands)

    Veenhof, A. A. F. A.; Vlug, M. S.; van der Pas, M. H. G. M.; Sietses, C.; van der Peet, D. L.; de Lange-de Klerk, E. S. M.; Bonjer, H. J.; Bemelman, W. A.; Cuesta, M. A.

    2012-01-01

    Objective: To evaluate the effect of laparoscopic or open colectomy with fast track or standard perioperative care on patient's immune status and stress response after surgery. Methods: Patients with nonmetastasized colon cancer were randomized to laparoscopic or open colectomy with fast track or

  5. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial).

    NARCIS (Netherlands)

    Wind, J.; Hofland, J.; Preckel, B.; Hollman, M.W.; Bossuyt, P.M.M.; Gouma, D.J.; Berge Henegouwen, M.I.; Fuhring, J.W.; Dejong, C.H.C.; Dam, R.M. van; Cuesta, M.A.; Noordhuis, A.; Jong, D. de; Zalingen, E. van; Engel, A.F.; Goei, T.H.; Stoppelaar, I.E. de; Tets, W.F. van; Wagensveld, B.A. van; Swart, A.; Elsen, M.J.L.J. van den; Gerhards, M.F.; Wit, L.Th. De; Siepel, M.A.M.; Geloven, A.A.W. van; Juttmann, J.-W.; Clevers, J.C.; Bemelman, W.A.

    2006-01-01

    BACKGROUND: Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay.The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst

  6. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial)

    NARCIS (Netherlands)

    Wind, Jan; Hofland, Jan; Preckel, Benedikt; Hollmann, Markus W.; Bossuyt, Patrick M. M.; Gouma, Dirk J.; van Berge Henegouwen, Mark I.; Fuhring, Jan Willem; Dejong, Cornelis H. C.; van Dam, Ronald M.; Cuesta, Miguel A.; Noordhuis, Astrid; de Jong, Dick; van Zalingen, Edith; Engel, Alexander F.; Goei, T. Hauwy; de Stoppelaar, I. Erica; van Tets, Willem F.; van Wagensveld, Bart A.; Swart, Annemiek; van den Elsen, Maarten J. L. J.; Gerhards, Michael F.; de Wit, Laurens Th; Siepel, Muriel A. M.; van Geloven, Anna A. W.; Juttmann, Jan-Willem; Clevers, Wilfred; Bemelman, Willem A.

    2006-01-01

    BACKGROUND: Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay.The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst

  7. Fast-track program in laparoscopic liver surgery: Theory or fact?

    Science.gov (United States)

    Sánchez-Pérez, Belinda; Aranda-Narváez, José Manuel; Suárez-Muñoz, Miguel Angel; Eladel-Delfresno, Moises; Fernández-Aguilar, José Luis; Pérez-Daga, Jose Antonio; Pulido-Roa, Ysabel; Santoyo-Santoyo, Julio

    2012-11-27

    To analyze our results after the introduction of a fast-track (FT) program after laparoscopic liver surgery in our Hepatobiliarypancreatic Unit. All patients (43) undergoing laparoscopic liver surgery between March 2004 and March 2010 were included and divided into two consecutive groups: Control group (CG) from March 2004 until December 2006 with traditional perioperative cares (17 patients) and fast-track group (FTG) from January 2007 until March 2010 with FT program cares (26 patients). Primary endpoint was the influence of the program on the postoperative stay, the amount of re-admissions, morbidity and mortality. Secondarily we considered duration of surgery, use of drains, conversion to open surgery, intensive cares needs and transfusion. Both groups were homogeneous in age and sex. No differences in technique, time of surgery or conversion to open surgery were found, but more malignant diseases were operated in the FTG, and then transfusions were higher in FTG. Readmissions and morbidity were similar in both groups, without mortality. Postoperative stay was similar, with a median of 3 for CG vs 2.5 for FTG. However, the 80.8% of patients from FTG left the hospital within the first 3 d after surgery (58.8% for CG). The introduction of a FT program after laparoscopic liver surgery improves the recovery of patients without increasing complications or re-admissions, which leads to a reduction of the stay and costs.

  8. BROADBAND RADIO POLARIMETRY AND FARADAY ROTATION OF 563 EXTRAGALACTIC RADIO SOURCES

    International Nuclear Information System (INIS)

    Anderson, C. S.; Gaensler, B. M.; Feain, I. J.; Franzen, T. M. O.

    2015-01-01

    We present a broadband spectropolarimetric survey of 563 discrete, mostly unresolved radio sources between 1.3 and 2.0 GHz using data taken with the Australia Telescope Compact Array. We have used rotation-measure synthesis to identify Faraday-complex polarized sources, those objects whose frequency-dependent polarization behavior indicates the presence of material possessing complicated magnetoionic structure along the line of sight (LOS). For sources classified as Faraday-complex, we have analyzed a number of their radio and multiwavelength properties to determine whether they differ from Faraday-simple polarized sources (sources for which LOS magnetoionic structures are comparatively simple) in these properties. We use this information to constrain the physical nature of the magnetoionic structures responsible for generating the observed complexity. We detect Faraday complexity in 12% of polarized sources at ∼1′ resolution, but we demonstrate that underlying signal-to-noise limitations mean the true percentage is likely to be significantly higher in the polarized radio source population. We find that the properties of Faraday-complex objects are diverse, but that complexity is most often associated with depolarization of extended radio sources possessing a relatively steep total intensity spectrum. We find an association between Faraday complexity and LOS structure in the Galactic interstellar medium (ISM) and claim that a significant proportion of the Faraday complexity we observe may be generated at interfaces of the ISM associated with ionization fronts near neutral hydrogen structures. Galaxy cluster environments and internally generated Faraday complexity provide possible alternative explanations in some cases

  9. Design of a 300-Watt Isolated Power Supply for Ultra-Fast Tracking Converters

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Ouyang, Ziwei; Petersen, Lars Press

    2015-01-01

    This paper presents the design of a medium-powerrating isolated power supply for ultra-fast tracking converters and MOS-gate driver circuits in medium and high voltage applications. The key feature of the design is its very low circuit input-to-output parasitic capacitance, which maximizes its...

  10. Faraday cup for analyzing multi-ion plasma

    International Nuclear Information System (INIS)

    Fujita, Takao

    1987-01-01

    A compact and convenient ion analyzer (a kind of a Faraday cup) is developed in order to analyze weakly ionized multi-ion plasmas. This Faraday cup consists of three mesh electrodes and a movable ion collector. With a negative gate pulse superimposed on the ion retarding bias, ions are analyzed by means of time-of-flight. The identification of ion species and measurements of ion density and ion temperature are studied. (author)

  11. SMAP Faraday Rotation

    Science.gov (United States)

    Le Vine, David

    2016-01-01

    Faraday rotation is a change in the polarization as signal propagates through the ionosphere. At L-band it is necessary to correct for this change and measurements are made on the spacecraft of the rotation angle. These figures show that there is good agreement between the SMAP measurements (blue) and predictions based on models (red).

  12. High patient satisfaction in 445 patients who underwent fast-track hip or knee replacement

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    BACKGROUND AND PURPOSE: Patient satisfaction is important in fast-track total hip and knee replacement (THR, TKR). We assessed: (1) how satisfied patients were with the treatment; (2) factors related to overall satisfaction; and (3) whether there was a difference between THR and TKR regarding...... length of stay (LOS) and patient satisfaction. PATIENTS AND METHODS: In this follow-up study, a consecutive series of 445 patients undergoing THR and TKR completed a questionnaire 2 weeks after discharge. LOS and short-term patient satisfaction with the fast-track management were measured. Patient...... satisfaction was measured using a numerical rating scale (NRS; 0-10). RESULTS: For THR, the median satisfaction score was 9-10 and for TKR it was 8.5-10 in all parameters. Older THR patients had higher overall satisfaction. No association was found between overall satisfaction following THR or TKR and sex...

  13. An assessment of the lifetime of Faraday shield elements

    International Nuclear Information System (INIS)

    Caughman, J.B.O. II; Ruzic, D.N.; Hoffman, D.J.; Langley, R.A.; Lewis, M.B.; Ryan, P.M.

    1990-01-01

    The interaction of plasma with rf fields from an ion cyclotron range of frequencies (ICRF) antenna has been studied to estimate the amount of Faraday shield erosion expected in normal ICRF heating operation. Plasma parameters and ion energies have been measured in the near field of an antenna and used in a model to estimate the erosion rate of the Faraday shield surface. Experiments were conducted on the RF Test Facility, a magnetic mirror device at Oak Ridge National Laboratory, using a single-strap resonant loop antenna with a two-tier Faraday shield. The outer tier, facing the plasma, was layered with graphite tiles. The antenna was operated at currents and voltages within 50% of those expected in tokamaks. The time-varying floating potential was measured with a capacitively coupled probe, and the time-averaged floating potential, electron temperature, and electron density were measured with a Langmuir probe. Ion energies were measured with a gridded energy analyser located below the antenna, and samples of silicon were placed on the Faraday shield surface to estimate the incident ion energy. The capacitive probe measurements show that the rf floating potential follows the magnetic field pattern of the antenna, indicating that the electromagnetic fields are responsible for the potential formation. Plasma parameters and ion energies have been correlated with the antenna current and used in a computational model of the plasma sheath to predict the amount of erosion expected from the Faraday shield elements exposed to plasma. Predictions of light ion sputtering of candidate Faraday shield materials are presented

  14. Observation of two-dimensional Faraday waves in extremely shallow depth.

    Science.gov (United States)

    Li, Xiaochen; Yu, Zhengyue; Liao, Shijun

    2015-09-01

    A family of two-dimensional Faraday waves in extremely shallow depth (1 mm to 2 mm) of absolute ethanol are observed experimentally using a Hele-Shaw cell that vibrates vertically. The same phenomena are not observed by means of water, ethanol solution, and silicone oil. These Faraday waves are quite different from the traditional ones. These phenomena are helpful to deepen and enrich our understandings about Faraday waves, and besides provide a challenging problem for computational fluid dynamics.

  15. Cognitive dysfunction after fast-track hip and knee replacement

    DEFF Research Database (Denmark)

    Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben

    2014-01-01

    to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). RESULTS: Median LOS was 2 days (interquartile range...... this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). CONCLUSIONS: The incidence of POCD early after total hip and knee replacement seems to be lower after a fast-track approach than rates previously reported...

  16. MUSIC for Faraday rotation measure synthesis

    Science.gov (United States)

    Andrecut, M.

    2013-03-01

    Faraday rotation measure (RM) synthesis requires the recovery of the Faraday dispersion function (FDF) from measurements restricted to limited wavelength ranges, which is an ill-conditioned deconvolution problem. Here, we propose a novel deconvolution method based on an extension of the MUltiple SIgnal Classification (MUSIC) algorithm. The complexity and speed of the method is determined by the eigen-decomposition of the covariance matrix of the observed polarizations. We show numerically that for high to moderate signal-to-noise ratio (S/N) cases the RM-MUSIC method is able to recover the Faraday depth values of closely spaced pairs of thin RM components, even in situations where the peak response of the FDF is outside of the RM range between the two input RM components. This result is particularly important because the standard deconvolution approach based on RM-CLEAN fails systematically in such situations, due to its greedy mechanism used to extract the RM components. For low S/N situations, both the RM-MUSIC and RM-CLEAN methods provide similar results.

  17. Faraday instability in a near-critical fluid under weightlessness.

    Science.gov (United States)

    Gandikota, G; Chatain, D; Amiroudine, S; Lyubimova, T; Beysens, D

    2014-01-01

    Experiments on near-critical hydrogen have been conducted under magnetic compensation of gravity to investigate the Faraday instability that arises at the liquid-vapor interface under zero-gravity conditions. We investigated such instability in the absence of stabilizing gravity. Under such conditions, vibration orients the interface and can destabilize it. The experiments confirm the existence of Faraday waves and demonstrate a transition from a square to a line pattern close to the critical point. They also show a transition very close to the critical point from Faraday to periodic layering of the vapor-liquid interface perpendicular to vibration. It was seen that the Faraday wave instability is favored when the liquid-vapor density difference is large enough (fluid far from the critical point), whereas periodic layering predominates for small difference in the liquid and vapor densities (close to the critical point). It was observed for the Faraday wave instability that the wavelength of the instability decreases as one approaches the critical point. The experimental results demonstrate good agreement to the dispersion relation for zero gravity except for temperatures very close to the critical point where a transition from a square pattern to a line pattern is detected, similarly to what is observed under 1g conditions.

  18. Clinical evidence of traditional vs fast track recovery methodologies after total arthroplasty for osteoarthritic knee treatment. A retrospective observational study

    Science.gov (United States)

    Castorina, Sergio; Guglielmino, Claudia; Castrogiovanni, Paola; Szychlinska, Marta Anna; Ioppolo, Francesco; Massimino, Paolo; Leonardi, Pietro; Maci, Christian; Iannuzzi, Maurizio; Di Giunta, Angelo; Musumeci, Giuseppe

    2017-01-01

    Summary Background During the last years, programs to enhance postoperative recovery and decrease morbidity after total knee arthroplasty, have been developed across a variety of surgical procedures and referred to as “Fast-Track Surgery”. In this study we aimed to find some answers in the management of osteoarthritic patients subjected to total knee arthroplasty, by using the Fast-Track methodology. To this purpose we evaluated parameters such as early mobilization of patients, better pain management, bleeding, possible complications, reduced hospitalization time, an overall improved recovery and patient satisfaction. Methods 132 patients were selected, of which, 95 treated with “Fast Track” method and 37 treated with traditional method (control group). All the patients were hospitalized and underwent the same rehabilitation program for the first three days after surgery. Results In both groups, the parameters of pain and deformity demonstrated the most rapid improvement, while those of function and movement were normalized as gradual and progressive improvement over the next 2 months. The different functional test used (Barthel, MRC, VAS) showed that the mean values were significantly greater in Fast Track group when compared to the control. Conclusion The results of the study confirm that the application of the Fast Track protocol in orthopaedics after total knee replacement results in rapid post-surgery recovery. Level of evidence IV. Case series, low-quality cohort or case-control studies. PMID:29387645

  19. Ultrafast magnetic vortex core switching driven by the topological inverse Faraday effect.

    Science.gov (United States)

    Taguchi, Katsuhisa; Ohe, Jun-ichiro; Tatara, Gen

    2012-09-21

    We present a theoretical discovery of an unconventional mechanism of inverse Faraday effect which acts selectively on topological magnetic structures. The effect, topological inverse Faraday effect, is induced by the spin Berry's phase of the magnetic structure when a circularly polarized light is applied. Thus a spin-orbit interaction is not necessary unlike that in the conventional inverse Faraday effect. We demonstrate by numerical simulation that topological inverse Faraday effect realizes ultrafast switching of a magnetic vortex within a switching time of 150 ps without magnetic field.

  20. Fast neutron dosimetry by means of different solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The comparative study of three different types of fast neutron dosimeters based on solid state nuclear track detectors is presented; the dosimeters studied were: - microscopic soda glass in contact with 232 Th; - polycarbonate Makrofol E; and - cellulose nitrate Kodak LR 115. All detectors were evaluated by visual counting in a microscope. The authors have studied such properties as the background, angular as well as energetical dependences of detectors. The results obtained show that all studied detectors are suitable for fast neutron dosimetry; their application depends however on the concrete experimental conditions (neutron spectrum, fluence etc.). Both advantages and disadvantages of each of them are presented. (Auth.)

  1. Electrochemical etching amplification of low-let recoil particle tracks in polymers for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Sohrabi, M.; Morgan, K.Z.

    1975-11-01

    An electrochemical etching method for the amplification of fast-neutron-induced recoil particle tracks in polymers was investigated. The technique gave superior results over those obtained by conventional etching methods especially when polycarbonate foils were used for recoil particle track amplification. Electrochemical etching systems capable of multi-foil processing were designed and constructed to demonstrate the feasibility of the techniques for large-scale neutron dosimetry. Electrochemical etching parameters were studied including the nature or type of the polymer foil used, foil thickness and its effect on etching time, the applied voltage and its frequency, the chemical composition, concentration, and temperature of the etchant, distance and angle between the electrodes, and the type of particles such as recoil particles including protons. Recoil particle track density, mean track diameter, and optical density as functions of the mentioned parameters were determined. Each parameter was found to have a distinct effect on the etching results in terms of the measured responses. Several new characteristics of this fast neutron dosimetry method were studied especially for personnel dosimetry using various radiation sources such as nuclear reactors, medical cyclotrons, and isotopic neutron sources. The dose range, neutron energy dependence, directional response, fading characteristics, neutron threshold energy, etc. were investigated

  2. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  3. Fast neutron detection by means of an organic solid state track detector

    International Nuclear Information System (INIS)

    Doerschel, B.; Streubel, G.

    1980-01-01

    Solid state track detectors consisting of cellulose triacetate foils are appropriate for measuring the fast neutron fluence without applying external radiators. Detector sensitivity has been determined as a function of neutron energy by performing irradiations with various neutron sources and monoenergetic neutrons of different energies. A comparison with theoretical results given in the literature for a simple model of track recording has shown sufficient agreement. The measuring errors and the influence of spectral changes in the neutron field on detector response are discussed for the studied method of fluence measurement. By means of these errors the measuring range has been determined for well defined irradiation conditions, taking into account spectral changes in the neutron field. (author)

  4. Nopea toipuminen lihavuusleikkauksen jälkeen : Fast track- toimintamallin mukainen potilasohjausvihko lihavuusleikkauspotilaalle Oulun yliopistollisen sairaalan osastolle yhdeksän

    OpenAIRE

    Niskala, Jenni; Nevala, Elisa

    2013-01-01

    Oulun yliopistollisen sairaalan osastolla yhdeksän oli tarve saada Fast track -toimintamallin mukainen potilasohjausvihko lihavuusleikkauspotilaille. Opinnäytetyön tekijät valitsivat opinnäytetyön aiheen perioperatiivisen suuntautumisvaihtoehdon mukaan. Tämä opinnäytetyö toteutettiin projektityönä. Opinnäytetyön tarkoituksena oli tehdä Fast track- toimintamallin mukainen potilasohjausvihko Oulun Yliopistollisen sairaalan osasto yhdeksän käyttöön. Opinnäytetyön tavoitteena oli edesauttaa ...

  5. Material and electromagnetic properties of Faraday shields for ion cyclotron heating antennas

    International Nuclear Information System (INIS)

    Hoffman, D.J.; Baity, F.W.; Becraft, W.R.; Caughman, J.B.O.; Tsai, C.C.

    1985-01-01

    The Faraday shields for ion cyclotron antennas must transmit magnetic waves and absorb little RF power. To investigate these properties, we have constructed 27 Faraday shields in many configurations, including chevrons, tubes, straps, concentric rings, various layered shields, conventionally leafed straps, and replicas of the Faraday shields for ASDEX, the Joint European Torus (JET), TEXTOR, and Alcator-C. We have measured the magnetic flux and observed loading at various operating resistances by using dielectric sheets or magnetic-coupled loads. Each Faraday shield effects a net change in the characteristic inductance of the antenna, resulting in a reduction of wave coupling. However, the load experienced by the antenna is not always reduced because the Faraday shield itself acts as a load. We differentiate between these effects experimentally. The net result of the study is that the Faraday shields now in use cost up to a factor of 50% of coupling. This, of course, reduces the power handling capability by 50% as well. However, configurations exist that are easily cooled and result in a reduction of less than 5% in loading

  6. Material and electromagnetic properties of Faraday shields for ion cyclotron heating antennas

    International Nuclear Information System (INIS)

    Hoffman, D.J.; Becraft, W.R.; Baity, F.W.; Caughman, J.B.O.; Tsai, C.C.

    1985-01-01

    The Faraday shields for ion cyclotron antennas must transmit magnetic waves and adsorb little rf power. To investigate these properties, we have constructed 27 Faraday shields in many configurations, including chevrons, tubes, straps, concentric rings, various layered shields, conventionally leafed straps, and replicas of the Faraday shields for ASDEX, the Joint European Torus (JET), TEXTOR, and Alcator-C. We have measured the magnetic flux and observed loading at various operating resistances by using dielectric sheets or magnetic-coupled loads. Each Faraday shield effects a net change in the characteristic inductance of the antenna, resulting in a reduction of wave coupling. However, the load experienced by the antenna is not always reduced because the Faraday shield itself acts as a load. We differentiate between these effects experimentally. The net result of the study is that the Faraday shields now in use cost up to a factor of 50% of coupling. This, of course, reduces the power handling capability by 50% as well. However, configurations exist that are easily cooled and result in a reduction of less than 5% in loading

  7. Faraday rotation measures in 20 AGN jets at parsec scale

    Directory of Open Access Journals (Sweden)

    Kravchenko Evgeniya V.

    2013-12-01

    Full Text Available We present multi wavelength parsec-scale Faraday rotation measure properties of twenty active galactic nuclei, observed with the Very Long Baseline Array simultaneously at 1.4, 1.6, 2.2, 2.4, 4.6, 5.0, 8.1, 8.4 and 15.4 GHz in the full polarization mode. For the observed sources we construct Faraday rotation measure and Faraday-corrected linear polarization maps. Direction of electrical field in the optically thick core regions confirms bimodal distribution. No significant changes of a Faraday rotation measure transverse to the jet direction are found in any of the observed sources. We propose a new magnetic field spatial geometry reconstruction method based on core shift measurements. This technique is applied to the quasar 1004+141. Results indicate an existence of a large scale poloidal magnetic field in the jet of 1004+141.

  8. Measurement of plasma conductivity using faraday rotation of submillimeter waves

    International Nuclear Information System (INIS)

    Kuzmenko, P.J.; Self, S.A.

    1983-01-01

    This paper examines the application of Faraday rotation to the measurement of electron combustion MHD plasmas. Details on the design of a working system are given, including the selection of operating wavelength. A theoretical comparison between the Faraday rotation technique and two-path interferometry shows Faraday rotation in its simplest form to be somewhat less sensitive to changes in electron concentration. This deficit can be balanced against greater immunity to vibration and thermal drift. Improved techniques of measuring the rotation angle promise greater sensitivity. A preliminary experiment has verified the technique

  9. The Faraday effect revisited

    DEFF Research Database (Denmark)

    Cornean, Horia; Nenciu, Gheorghe

    2009-01-01

    This paper is the second in a series revisiting the (effect of) Faraday rotation. We formulate and prove the thermodynamic limit for the transverse electric conductivity of Bloch electrons, as well as for the Verdet constant. The main mathematical tool is a regularized magnetic and geometric...

  10. Galactic foreground science: Faraday Tomography at low frequencies

    Science.gov (United States)

    Haverkorn, Marijke

    2018-05-01

    This contribution describes how low-frequency radio-spectropolarimetric imaging as done for Epoch of Reionization detection is used to investigate the nearby Galactic interstellar medium. The method of Faraday Tomography allows disentangling of every line of sight into various components in Faraday depth, which is a proxy for density-weighted magnetic field. I discuss instrumental biases and side effects of this method, and early results it has yielded.

  11. An assessment of the lifetime of Faraday shield elements

    International Nuclear Information System (INIS)

    Caughman, J.B.O. II; Ruzic, D.N.; Hoffman, D.J.; Langley, R.A.; Lewis, M.B.; Ryan, P.M.

    1989-01-01

    The interaction of plasma with rf fields from an ion cyclotron range of frequencies (ICRF) antenna has been studied to estimate the amount of Faraday shield erosion expected in normal ICRF heating (ICRH) operation. Plasma parameters and ion energies have been measured in the near field of an antenna and used in a model to estimate the erosion rate of the Faraday shield surface. Experiments were conducted on the RF Test Facility (RFTF), a magnetic mirror device at Oak Ridge National Laboratory (ORNL), using a single-strap resonant loop antenna with a two-tier Faraday shield. The outer tier, facing the plasma, was layered with graphite tiles. The antenna was operated at currents and voltages (∼500 A, ∼20 kV at 25 kW) within 50% of those expected in tokamaks. The time varying floating potential was measured with a capacitively coupled probe, and the time-averaged floating potential, electron temperature, and electron density were measured with a Langmuir probe. Both probes were scanned in front of the antenna. Ion energies were measured with a gridded energy analyzer located below the antenna, and samples of silicon were placed on the Faraday shield surface to estimate the incident ion energy. The capacitive probe measurements show that the rf floating potential follows the magnetic field pattern of the antenna, indicating that the electromagnetic fields are responsible for the potential formation. Plasma parameters and ion energies have been correlated with the antenna current and used in s computational model of the plasma sheath to predict the amount of erosion expected from the Faraday shield elements exposed to plasma. Predictions of light ion sputtering of candidate Faraday shield materials are presented. 19 refs., 6 figs., 1 tab

  12. Anisotropy of the Faraday effect in the weak ferromagnet YFeO3

    International Nuclear Information System (INIS)

    Zenkov, A.V.; Krichevtsov, B.B.; Moskvin, A.S.; Mukimov, K.M.; Pisarev, R.V.; Ruvinshtein, M.M.

    1989-01-01

    An experimental investigation was made of the magnetic-field dependence of the Faraday effect in a weak ferromagnet YFeO 3 at the wavelength λ = 0.63 μm. Measurements were made for different orientations of the direction of light propagation k and of the magnetic field H. Changes in the Faraday effect in the k parallel c, H parallel a case were not proportional to changes in the component of the magnetic moment m z . A phenomenological description of the Faraday effect in YFeO 3 was used to separate the ferromagnetic, antiferromagnetic, and diamagnetic contributions to the effect. The antiferromagnetic contribution dominating the Faraday effect was strongly anisotropic. A theoretical analysis was made of the microscopic Faraday effect mechanisms in YFeO 3 using the example of a dipole-allowed transition 6 A 1g → 6 T 1u

  13. Impact of fast-track concept elements in the classical pancreatic head resection (Kausch-Whipple procedure).

    Science.gov (United States)

    Gastinger, Ingo; Meyer, Frank; Lembcke, Thomas; Schmidt, Uwe; Ptok, Henry; Lippert, Hans

    2012-08-01

    The aim of the study was to determine statistically significant factors with an impact on the early postoperative surgical outcome. The influence of applied fast-track components on surgical results and early postoperative outcome in 143 consecutive Kausch-Whipple procedure patients was evaluated in a single-center retrospective analysis of a prospective collection of patient-associated pre-, peri- and postoperative data from 1997-2006. The in-hospital mortality rate was 2.8% (n=4). Fast-track measures were shown to have no effect on the morbidity rate in the multi-variate analysis. Over the study period, a decrease of intraoperative infusion volume from 14.2 mL/kg body weight/h in the first year to 10.7 mL/kg body weight/h in the last year was accompanied by an increase in patients requiring intraoperative catecholamines, up from 17% to 95%. The administration of ropivacain/sufentanil via thoracic peri-dural catheter injection initiated in 2000 and now considered the leading analgesic method, was used in 95% of the cases in 2006. Early extubation rate rose from 16.6% to 57.9%. Fast-track aspects in the perioperative management have become more important in several surgical procedure even in those with a greater invasiveness such as Kausch-Whipple. However, such techniques used in peri-operative management of Kausch-Whipple pancreatic-head resections had no impact on the morbidity rate. In addition, the low in-hospital mortality rate was particularly attributed to surgical competence.

  14. HIE-ISOLDE Faraday cups tested with ion beams at TRIUMF

    CERN Document Server

    Cantero, E D

    2014-01-01

    The future HIE-ISOLDE Faraday cups for both the intercryomodule regions and the HEBTs have been tested using 34S+7, 4He+, 23Na+6 and 20Ne+5 beams from the ISAC-II accelerator at TRIUMF. Their performance has been characterized together with the Faraday cups from REX-ISOLDE and those from ISAC-II. The measurements were done at E/A = 1.5, 2.85 and 5.5 MeV/u, with beam intensities in the range of 100 pA to 4 nA. The performance of these Faraday cups has been compared under the same beam conditions for different bias voltages up to -350 V. Within the experimental uncertainties, most of them coming from fluctuations in beam intensity, all devices showed similar results. Biasing the Faraday cup repeller ring to voltages of at least -60 V, the escape of secondary electrons was suppressed.

  15. Thin Film Magnetless Faraday Rotators for Compact Heterogeneous Integrated Optical Isolators (Postprint)

    Science.gov (United States)

    2017-06-15

    AFRL-RX-WP-JA-2017-0348 THIN-FILM MAGNETLESS FARADAY ROTATORS FOR COMPACT HETEROGENEOUS INTEGRATED OPTICAL ISOLATORS (POSTPRINT) Dolendra Karki...Interim 9 May 2016 – 1 December 2016 4. TITLE AND SUBTITLE THIN-FILM MAGNETLESS FARADAY ROTATORS FOR COMPACT HETEROGENEOUS INTEGRATED OPTICAL...transfer of ultra-compact thin-film magnetless Faraday rotators to silicon photonic substrates. Thin films of magnetization latching bismuth

  16. Recent VLA Measurements of CME-Induced Faraday Rotation

    Science.gov (United States)

    Kooi, Jason; Thomas, Najma; Guy, Michael; Spangler, Steven R.

    2018-01-01

    Observations of Faraday rotation, the change in polarization position angle of linearly polarized radiation as it propagates through a magnetized plasma, have been used for decades to determine the strength and structure of the coronal magnetic field and plasma density. Similarly, observations of Faraday rotation through a coronal mass ejection (CME) have the potential to improve our understanding of the CME’s plasma structure. We report recent results from simultaneous white-light coronagraph and radio observations made of a CME in July 2015. We made radio observations using the Karl G. Jansky Very Large Array (VLA) at 1 - 2 GHz frequencies of a set of cosmic radio sources through the solar corona at heliocentric distances that ranged between 8 - 23 solar radii. A unique aspect of these observations is that the CME occulted several of these radio sources and, therefore, our Faraday rotation measurements provide information on the plasma structure in different regions of the CME. We successfully measured CME-induced Faraday rotation along multiple lines of sight because we made special arrangements with the staff at the National Radio Astronomy Observatory to trigger VLA observations when a candidate CME appeared low in the corona in near real-time images from the Large Angle and Spectrometric Coronagraph (LASCO) C2 instrument.

  17. SMEs in Energy: Are they the parallel fast track for electrification of Africa?

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rahman, Mohamed

    2010-09-15

    The African continent is suffering from a chronic energy shortage that hiders its development. The conventional wisdom is to put the Mega projects under focus. However, a parallel fast track for the energy as an SME business may bring faster results to the continent. To that end, this paper presents proposed steps to promote the concept within the continent.

  18. Measurement of the effects of Faraday shields on ICRH antenna coupling

    International Nuclear Information System (INIS)

    Kwon, M.; Thomas, C.E. Jr.; Rettig, C.L.

    1990-01-01

    Compact loop antennas are being applied to several fusion experiments. Although individual configurations vary, all of these antennas generally comprise a current strap in a recessed box and a Faraday shield. The effect of the cross-sectional shape of the current strap on voltage and current levels was measured. In this work the coupling characteristics of cavity antennas that have current straps with the previously evaluated cross-sectional shapes re tested with several Faraday shields. Impedances and relative fields are measured for various combinations of the current strap and Faraday shield. The experiments show that the fractional reduction in the magnetic flux linkage to the plasma resulting from the addition of any particular Faraday shield i virtually independent of the shape of the current strap. This is true in spite of the fact that the same mechanism which is responsible for the reduction in flux is also responsible for a significant redistribution of the antenna current on the current strap. Thus the process of optimizing antennas is reduced to that of separately optimizing the current strap and Faraday shield

  19. Fast Tracker: A Hardware Real Time Track Finder for the ATLAS Trigger System

    CERN Document Server

    Kimura, N; The ATLAS collaboration

    2014-01-01

    The Fast Tracker (FTK) is an integral part of the trigger upgrade program for the ATLAS detector at the Large Hadron Collider (LHC). As the LHC luminosity approaches its design level of 10^34cm^−2s^−1, the combinatorial problem posed by charged particle tracking becomes increasingly difficult due to the swelling of multiple interactions per bunch crossing (pile-up). The FTK is a highly-parallel hardware system intended to provide high-quality tracks with transverse momentum above 1 GeV/c in real time for online trigger system. The FTK system’s design, based on a mixture of advanced technologies, and expected physics performance will be presented.

  20. Faraday rotation dispersion microscopy imaging of diamagnetic and chiral liquids with pulsed magnetic field.

    Science.gov (United States)

    Suwa, Masayori; Nakano, Yusuke; Tsukahara, Satoshi; Watarai, Hitoshi

    2013-05-21

    We have constructed an experimental setup for Faraday rotation dispersion imaging and demonstrated the performance of a novel imaging principle. By using a pulsed magnetic field and a polarized light synchronized to the magnetic field, quantitative Faraday rotation images of diamagnetic organic liquids in glass capillaries were observed. Nonaromatic hydrocarbons, benzene derivatives, and naphthalene derivatives were clearly distinguished by the Faraday rotation images due to the difference in Verdet constants. From the wavelength dispersion of the Faraday rotation images in the visible region, it was found that the resonance wavelength in the UV region, which was estimated based on the Faraday B-term, could be used as characteristic parameters for the imaging of the liquids. Furthermore, simultaneous acquisition of Faraday rotation image and natural optical rotation image was demonstrated for chiral organic liquids.

  1. A 2D semi-analytical model for Faraday shield in ICP source

    International Nuclear Information System (INIS)

    Zhang, L.G.; Chen, D.Z.; Li, D.; Liu, K.F.; Li, X.F.; Pan, R.M.; Fan, M.W.

    2016-01-01

    Highlights: • In this paper, a 2D model of ICP with faraday shield is proposed considering the complex structure of the Faraday shield. • Analytical solution is found to evaluate the electromagnetic field in the ICP source with Faraday shield. • The collision-free motion of electrons in the source is investigated and the results show that the electrons will oscillate along the radial direction, which brings insight into how the RF power couple to the plasma. - Abstract: Faraday shield is a thin copper structure with a large number of slits which is usually used in inductive coupled plasma (ICP) sources. RF power is coupled into the plasma through these slits, therefore Faraday shield plays an important role in ICP discharge. However, due to the complex structure of the Faraday shield, the resulted electromagnetic field is quite hard to evaluate. In this paper, a 2D model is proposed on the assumption that the Faraday shield is sufficiently long and the RF coil is uniformly distributed, and the copper is considered as ideal conductor. Under these conditions, the magnetic field inside the source is uniform with only the axial component, while the electric field can be decomposed into a vortex field generated by changing magnetic field together with a gradient field generated by electric charge accumulated on the Faraday shield surface, which can be easily found by solving Laplace's equation. The motion of the electrons in the electromagnetic field is investigated and the results show that the electrons will oscillate along the radial direction when taking no account of collision. This interesting result brings insight into how the RF power couples into the plasma.

  2. Anisotropy of the Faraday effect in the weak ferromagnetic YFeO3

    International Nuclear Information System (INIS)

    Zenkov, A.V.; Krichevtsov, B.B.; Moskvin, A.S.; Mukimov, K.M.; Pisarev, R.V.; Ruvinshtejn, M.M.

    1989-01-01

    The field strength dependence of the Faraday effect in the weak ferromagnetic YFeO 3 at the wavelength λ=0.63 μm are investigated experimentally for various directions of propagation of the light k-vector and magnetic field H-vector. It is shown that the variation of the Faraday effect for k-vector parallel c-vector and H-vector parallel a-vector is not proportional to the change of the magnetic moment component m z . The ferro-, antiferro- and diamagnetic contributions to the Faraday effect are separated on the basis of a phenomenological description of the Faraday effect in YFeO 3 . It is found that the antiferromagnetic contribution which determines the Faraday effect is strongly anisotropic. The microscopic mechanisms of the Faraday effect in YFeO 3 are considered theoretically for the case of the dipole-allowed 6 A 1g → 6 T 1u transition. It is shown that the mechanisms proposed earlier cannot explain the strong anisotropy of the antiferromagnetic contribution. In order to explain the anisotropy the spin-foreign orbit exchange-relativistic interaction should be taken into account

  3. Faraday effect in Hg1-xMnxTe semimagnetic semiconductors

    International Nuclear Information System (INIS)

    Savchuk, A.I.; Frasunyak, V.M.; Fediv, V.I.

    1995-01-01

    Results on studies of spectral and temperature dependencies of the Faraday rotation in the Hg 1-x Mn x Te semiconductors are presented. It is shown that the Faraday rotation spectral dependence in the Hg 1-x Mn x Te crystals corresponds to model of the Faraday giant effect in other A 1-x 2 Mn x B 6 semimagnetic semiconductors, caused by strong exchange interaction between Mn d-electrons and s,p - zone carriers. The phase transition into the glass spin state is observed in the Hg 1-x Mn x Te crystals with Mn high content. 5 refs.; 2 figs

  4. Electrical control of Faraday rotation at a liquid-liquid interface.

    Science.gov (United States)

    Marinescu, Monica; Kornyshev, Alexei A; Flatté, Michael E

    2015-01-01

    A theory is developed for the Faraday rotation of light from a monolayer of charged magnetic nanoparticles at an electrified liquid-liquid interface. The polarization fields of neighboring nanoparticles enhance the Faraday rotation. At such interfaces, and for realistic sizes and charges of nanoparticles, their adsorption-desorption can be controlled with a voltage variationFaraday rotation. A calculation based on the Maxwell-Garnett theory predicts that the corresponding redistribution of 40 nm nanoparticles of yttrium iron garnet can switch a cavity with a quality factor larger than 10(4) for light of wavelength 500 nm at normal incidence.

  5. "Joined up" Thinking? Unsupported "Fast-Track" Transitions in the Context of Parental Substance Use

    Science.gov (United States)

    Wilson, Sarah; Cunningham-Burley, Sarah; Bancroft, Angus; Backett-Milburn, Kathryn

    2008-01-01

    Recent policy responses to the risks entailed in "fast-track" school-work transitions have targeted careleavers and young people identified as "not in education, employment or training" (NEET). However, this approach has been criticised as diverting attention away from the fragile circumstances of others who may receive little…

  6. Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Fabian; Rief, Matthias; Zimmermann, Elke; Greupner, Johannes; Richter, Felicitas; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany)

    2014-06-15

    Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. (orig.)

  7. Fast-track remediation case study: Southern California refined fuel distributor

    International Nuclear Information System (INIS)

    Bubier, T.W.; Felix, P.R.

    1993-01-01

    Successful environmental remediation projects have three requirements in common: (1) an adequate data base that defines the extent and severity of the problem; (2) a detailed understanding of the actual performance of the remediation technologies being considered; and (3) good communication with the regulatory agencies to assure them that the health and safety of the community and workers will not be jeopardized. In a fast-track remediation project, these requirements are key issues in the critical path. The case study involves soil and groundwater remediation of a 16-acre bulk fuel storage and distribution facility. The facility was in operation for approximately 75 years and contained 20 large aboveground tanks with a total capacity in excess of 20 million gallons. Activities at the facility included receipt, storage, and distribution of refined fuel products, such as kerosene, gasoline, diesel, and bunker fuel. A harbor-widening project was undertaken to increase the level of safety for larger ships when passing through the port. Because of the critical need for harbor-widening, the environmental cleanup needed to be completed as quickly as possible. The following steps were taken during the fast-track remediation case study to meet the above-listed requirements: (1) New Data Quality Objectives (DQOs) were identified for the project; (2) Potentially applicable remedial technologies were evaluated and tested; and (3) An agency task force was developed to enhance communication with the regulatory agencies. This paper discusses these steps and presents examples of how each step was implemented during the remediation case study

  8. Ballistic and diffusive dynamics in a two-dimensional ideal gas of macroscopic chaotic Faraday waves.

    Science.gov (United States)

    Welch, Kyle J; Hastings-Hauss, Isaac; Parthasarathy, Raghuveer; Corwin, Eric I

    2014-04-01

    We have constructed a macroscopic driven system of chaotic Faraday waves whose statistical mechanics, we find, are surprisingly simple, mimicking those of a thermal gas. We use real-time tracking of a single floating probe, energy equipartition, and the Stokes-Einstein relation to define and measure a pseudotemperature and diffusion constant and then self-consistently determine a coefficient of viscous friction for a test particle in this pseudothermal gas. Because of its simplicity, this system can serve as a model for direct experimental investigation of nonequilibrium statistical mechanics, much as the ideal gas epitomizes equilibrium statistical mechanics.

  9. Fast parallel tracking algorithm for the muon detector of the CBM experiment at FAIR

    International Nuclear Information System (INIS)

    Lebedev, A.; Hoehne, C.; Kisel', I.; Ososkov, G.

    2010-01-01

    Particle trajectory recognition is an important and challenging task in the Compressed Baryonic Matter (CBM) experiment at the future FAIR accelerator at Darmstadt. The tracking algorithms have to process terabytes of input data produced in particle collisions. Therefore, the speed of the tracking software is extremely important for data analysis. In this contribution, a fast parallel track reconstruction algorithm, which uses available features of modern processors is presented. These features comprise a SIMD instruction set (SSE) and multithreading. The first allows one to pack several data items into one register and to operate on all of them in parallel thus achieving more operations per cycle. The second feature enables the routines to exploit all available CPU cores and hardware threads. This parallel version of the tracking algorithm has been compared to the initial serial scalar version which uses a similar approach for tracking. A speed-upfactor of 487 was achieved (from 730 to 1.5 ms/event) for a computer with 2 x Intel Core 17 processors at 2.66 GHz

  10. Hardware-based Tracking at Trigger Level for ATLAS the Fast TracKer (FTK) Project

    CERN Document Server

    INSPIRE-00245767

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing under nominal conditions. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level-1 trigger (at a maximum rate of 100 kHz) the FTK receives data from all the channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware-based track reconstruction, using associative memory that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. An overview of the FTK system with focus on the pattern matching procedure will be p...

  11. A novel Cs-(129)Xe atomic spin gyroscope with closed-loop Faraday modulation.

    Science.gov (United States)

    Fang, Jiancheng; Wan, Shuangai; Qin, Jie; Zhang, Chen; Quan, Wei; Yuan, Heng; Dong, Haifeng

    2013-08-01

    We report a novel Cs-(129)Xe atomic spin gyroscope (ASG) with closed-loop Faraday modulation method. This ASG requires approximately 30 min to start-up and 110 °C to operate. A closed-loop Faraday modulation method for measurement of the optical rotation was used in this ASG. This method uses an additional Faraday modulator to suppress the laser intensity fluctuation and Faraday modulator thermal induced fluctuation. We theoretically and experimentally validate this method in the Cs-(129)Xe ASG and achieved a bias stability of approximately 3.25 °∕h.

  12. Fabrication of Faraday Cup Array for the Measurement of 2-Dimensional Proton Beam Profile

    International Nuclear Information System (INIS)

    Jung, Myunghwan; Kim, Bom Sok; Kim, Kyeryung

    2014-01-01

    It has an advantage of easy-to-use and possible to visually check, immediately; on the other hand, the measurement range is very limited. Another method is using the CCD camera-scintillator device such as p43 phosphor screen or chromox. A variety of faraday cup detectors have been recently introduced. The faraday cup is one of the powerful and popular tools for the measurement of beam current. By using several faraday cups in array geometry, it is possible to observe current distribution. In this study, we developed an external faraday cup array for the measure the beam current and profile at a KOMAC (Korea Multi-purpose Accelerator Complex) beam utilization facility. To measure the beam profile, before fabrication of faraday cup array, we use gafchromic film. By making the faraday cup array we were able to reduce the consumption of Gafchromic film and a more accurate diagnosis of the proton beam is possible. The use of faraday cup array, experiment using the proton beam is more reliable and confident

  13. A Fast Track towards the `Higgs' Spin and Parity

    CERN Document Server

    Ellis, John; Sanz, Veronica; You, Tevong

    2012-01-01

    The LHC experiments ATLAS and CMS have discovered a new boson that resembles the long-sought Higgs boson: it cannot have spin one, and has couplings to other particles that increase with their masses, but the spin and parity remain to be determined. We show here that the `Higgs' + gauge boson invariant-mass distribution in `Higgs'-strahlung events at the Tevatron or the LHC would be very different under the J^P = 0+, 0- and 2+ hypotheses, and could provide a fast-track indicator of the `Higgs' spin and parity. Our analysis is based on simulations of the experimental event selections and cuts using PYTHIA and Delphes, and incorporates statistical samples of `toy' experiments.

  14. A midsize tokamak as a fast track to burning plasmas

    Directory of Open Access Journals (Sweden)

    E. Mazzucato

    2011-03-01

    Full Text Available This paper describes the conceptual design of a midsize tokamak as a fast track to the investigation of burning plasmas. It is shown that it could reach large values of energy gain (≥ 10 with only a modest improvement in confinement over the scaling that was used for designing the International Thermonuclear Experimental Reactor (ITER. This can be achieved by operating in a low plasma recycling regime that experiments indicate can lead to improved plasma confinement. The possibility of reaching the necessary conditions of low recycling using a different magnetic divertor from those currently employed in present experiments is discussed.

  15. Fast ion loss diagnostic plans for NSTX

    International Nuclear Information System (INIS)

    Darrow, D. S.; Bell, R.; Johnson, R.; Kugel, H.; Wilson, J. R.; Cecil, F. E.; Maingi, R.; Krasilnikov, A.; Alekseyev, A.

    2000-01-01

    The prompt loss of neutral beam ions from the National Spherical Torus Experiment (NSTX) is expected to be between 12% and 42% of the total 5 MW of beam power. There may, in addition, be losses of fast ions arising from high harmonic fast wave (HHFW) heating. Most of the lost ions will strike the HHFW antenna or the neutral beam dump. To measure these losses in the 2000 experimental campaign, thermocouples in the antenna, several infrared camera views, and a Faraday cup lost ion probe will be employed. The probe will measure loss of fast ions with E > 1 keV at three radial locations, giving the scrape-off length of the fast ions

  16. A Comparative Study of Analog Voltage-mode Control Methods for Ultra-Fast Tracking Power Supplies

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper presents a theoretical and experimental comparison of the standard PWM/PID voltage-mode control method for single-phase buck converters with two highperformance self-oscillating (a.k.a. sliding mode) control methods. The application considered is ultra-fast tracking power supplies...... (UFTPSs) for RF power amplifiers, where the switching converter needs to track a varying reference voltage precisely and quickly while maintaining low output impedance. The small-signal analyses performed on the different controllers show that the hysteretic-type controller can achieve the highest loop...

  17. Faraday rotation in jets of AGN: the case of 3C 120

    International Nuclear Information System (INIS)

    Gómez, José L; Roca-Sogorb, Mar; Agudo, Iván; Marscher, Alan P; Jorstad, Svetlana G

    2012-01-01

    The source of Faraday rotation in the jet of the radio galaxy 3C 120 is analyzed through Very Long Baseline Array observations carried out between 1999 and 2007 at 15, 22 and 43 GHz. Uncorrelated changes in the linear polarization of the underlying jet emission and the Faraday rotation screen indicate that the emitting jet and the source of Faraday rotation are not closely connected physically and have different configurations for the magnetic field and/or kinematical properties. Furthermore, the existence of a region of enhanced rotation measure whose properties remain constant over three years requires a localized source of Faraday rotation, favoring a model in which a significant fraction of the rotation measure originates in foreground clouds.

  18. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Thorborg, Kristian; Husted, Henrik

    2013-01-01

    By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.......By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits....

  19. Opportune acquisition and tracking time for the fast-moving targets in a ground-based telescope

    Science.gov (United States)

    Chen, Juan; Wang, Jianli; Chen, Tao

    2004-10-01

    Acquisition is defined as identification for a fixed target in the related field of sight (FOS), while tracking means the sway of the telescope's axis of sight (AOS). The automatic acquisition and tracking is a process in which the operating way of the telescope should be switched from guiding to automatic tracking. There are some kinds of method to improve the acquisition and tracking ability for fast moving targets: to extend the acquisition and tracking FOS with memory and storage information of the sensor system; the multimode control to improve the dynamic property of the servo system; to choose an opportune time for acquisition and tracking; to select the control regulator parameter in every working states. If the processor of the CCD sensor can temporarily remember and save the information of the target before it moves out of the FOS, correspondingly, the FOS may be extended. The data forecast technology is used to store the target information. The automatic interception experiments are carried out to verify the control strategy.

  20. Improving the ATLAS physics potential with the Fast Track Trigger System

    CERN Document Server

    Cavaliere, Viviana; The ATLAS collaboration

    2015-01-01

    The ATLAS Fast TracKer (FTK) is a custom electronics system that will operate at the full Level-1 accept rate, 100 kHz, to provide high quality tracks as input to the High-Level Trigger. The event reconstruction is performed in hardware, thanks to the massive parallelism of associative memories (AM) and FPGAs. We present the advantages for the physics goals of the ATLAS experiment and the recent results on the design, technological advancements and testing of some of the core components used in the processor.

  1. Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO

    Science.gov (United States)

    Wintemitz, Luke; Boegner, Greg; Sirotzky, Steve

    2004-01-01

    A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.

  2. Faraday cup for electron flux measurements on the microtron MT 25

    International Nuclear Information System (INIS)

    Vognar, M.; Simane, C.; Chvatil, D.

    2001-01-01

    The basic design criteria for construction of an evacuated Faraday cup for precise measurement of 5-25 MeV electron beam currents in air from a microtron are characterized. The homemade Faraday cup is described along with the electronic chain and its incorporation into the measuring beam line. The provisions applied to reduce backward electron escape are outlined. The current range was 10 -5 to 10 -10 A. The diameter of the Al entrance window of the Faraday cup was 1.8 cm, its area was 2.54 cm 2 and thickness 0.1 mm

  3. A reengineering success story: process improvement in emergency department x-ray cycle time, leading to breakthrough performance in the ED ambulatory care (Fast Track) process.

    Science.gov (United States)

    Espinosa, J A; Treiber, P M; Kosnik, L

    1997-01-01

    This article describes the journey of a multidisciplinary reengineering team, which worked to reduce a critical, high-leverage process in an emergency department setting. The process selected was emergency department radiology services. This process was selected on a rational basis. The team knew tht 60 percent of our emergency department patients were truly ambulatory, and that most could be seen in a "fast track" process as part of our emergency department's core mission. However, we knew from customer satisfaction data, that patients would like to be "in and out" of emergency department Fast Track in less than an hour. Over half of our Fast Track patients require x-rays. For most, this was their sole reason for seeking emergency care. Our state, at the start of the project, included an average x-ray cycle time of over 60 minutes. The associated Fast-Track cycle time was over 90 minutes median. It was clear to the emergency department leadership, as well as to members of the Fast-Track management team, that a cycle time of 30 minutes or less for x-ray service was needed as a necessary condition to an hour or less Fast Track cycle time. It was also felt that a more rapid x-ray cycle time would allow for more rapid turn over of ED rooms, leading to a virtual greater capacity to the ED. It was hoped that this would lead to a reduction in the time from arrival to treatment by the emergency physician for all patients.

  4. International collaborative project to compare and track the nutritional composition of fast foods

    Directory of Open Access Journals (Sweden)

    2012-07-01

    Full Text Available Abstract Background Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Methods/design Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. Discussion This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  5. International collaborative project to compare and track the nutritional composition of fast foods.

    Science.gov (United States)

    2012-07-27

    Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  6. Cavity-enhanced Faraday rotation measurement with auto-balanced photodetection.

    Science.gov (United States)

    Chang, Chia-Yu; Shy, Jow-Tsong

    2015-10-01

    Optical cavity enhancement for a tiny Faraday rotation is demonstrated with auto-balanced photodetection. This configuration is analyzed using the Jones matrix formalism. The resonant rotation signal is amplified, and thus, the angular sensitivity is improved. In the experiment, the air Faraday rotation is measured with an auto-balanced photoreceiver in single-pass and cavity geometries. The result shows that the measured Faraday rotation in the single-pass geometry is enhanced by a factor of 85 in the cavity geometry, and the sensitivity is improved to 7.54×10(-10)  rad Hz(-1/2), which agrees well with the Jones matrix analysis. With this verification, we propose an AC magnetic sensor whose magnetic sensitivity is expected to achieve 10  pT Hz(-1/2).

  7. On Faraday's law in the presence of extended conductors

    Science.gov (United States)

    Bilbao, Luis

    2018-06-01

    The use of Faraday's Law of induction for calculating the induced currents in an extended conducting body is discussed. In a general case with arbitrary geometry, the solution to the problem of a moving metal object in the presence of a magnetic field is difficult and implies solving Maxwell's equations in a time-dependent situation. In many cases, including cases with good conductors (but not superconductors) Ampère's Law can be neglected and a simpler solution based solely in Faraday's law can be obtained. The integral form of Faraday's Law along any loop in the conducting body is equivalent to a Kirkhhoff's voltage law of a circuit. Therefore, a numerical solution can be obtained by solving a linear system of equations corresponding to a discrete number of loops in the body.

  8. High-field Faraday rotation in II-VI-based semimagnetic semiconductors

    NARCIS (Netherlands)

    Savchuk, AI; Fediv, [No Value; Nikitin, PI; Perrone, A; Tatzenko, OM; Platonov, VV

    The effects of d-d exchange interaction have been studied by measuring high-field Faraday rotation in II-VI-based semimagnetic semiconductors. For Cd1-xMnxTe crystals with x = 0.43 and at room temperature a saturation in magnetic field dependence of the Faraday rotation has been observed. In the

  9. Comparison of algorithms for determination of rotation measure and Faraday structure. I. 1100–1400 MHz

    International Nuclear Information System (INIS)

    Sun, X. H.; Akahori, Takuya; Anderson, C. S.; Farnes, J. S.; O’Sullivan, S. P.; Rudnick, L.; O’Brien, T.; Bell, M. R.; Bray, J. D.; Scaife, A. M. M.; Ideguchi, S.; Kumazaki, K.; Stepanov, R.; Stil, J.; Wolleben, M.; Takahashi, K.; Weeren, R. J. van

    2015-01-01

    Faraday rotation measures (RMs) and more general Faraday structures are key parameters for studying cosmic magnetism and are also sensitive probes of faint ionized thermal gas. A definition of which derived quantities are required for various scientific studies is needed, as well as addressing the challenges in determining Faraday structures. A wide variety of algorithms has been proposed to reconstruct these structures. In preparation for the Polarization Sky Survey of the Universe's Magnetism (POSSUM) to be conducted with the Australian Square Kilometre Array Pathfinder and the ongoing Galactic Arecibo L-band Feeds Array Continuum Transit Survey (GALFACTS), we run a Faraday structure determination data challenge to benchmark the currently available algorithms, including Faraday synthesis (previously called RM synthesis in the literature), wavelet, compressive sampling, and QU-fitting. The input models include sources with one Faraday thin component, two Faraday thin components, and one Faraday thick component. The frequency set is similar to POSSUM/GALFACTS with a 300 MHz bandwidth from 1.1 to 1.4 GHz. We define three figures of merit motivated by the underlying science: (1) an average RM weighted by polarized intensity, RM wtd , (2) the separation Δϕ of two Faraday components, and (3) the reduced chi-squared χ r 2 . Based on the current test data with a signal-to-noise ratio of about 32, we find the following. (1) When only one Faraday thin component is present, most methods perform as expected, with occasional failures where two components are incorrectly found. (2) For two Faraday thin components, QU-fitting routines perform the best, with errors close to the theoretical ones for RM wtd but with significantly higher errors for Δϕ. All other methods, including standard Faraday synthesis, frequently identify only one component when Δϕ is below or near the width of the Faraday point-spread function. (3) No methods as currently implemented work well

  10. Simple theory of the inverse Faraday effect with relationship to optical constants N and K

    International Nuclear Information System (INIS)

    Yoshino, Toshihiko

    2011-01-01

    The inverse Faraday effect in general materials is theoretically investigated based on the classical motion of an electron. It is shown that the inverse Faraday effect is simply and explicitly expressed in terms of optical constants N and K, i.e., the real and imaginary parts of complex refractive index of materials. The derived new formula provides a good physical perspective for the inverse Faraday effect and enables its easy quantitative evaluation from familiar optical constants. - Highlights: → The theory of the inverse Faraday effect in general materials is presented based on the classical motion model of electron. → The simple relationship between optical constants of materials and the inverse Faraday effect is given. → The given new formula enables easy quantitative evaluation of the inverse Faraday effect from known optical constants.

  11. Faster recovery of gastrointestinal transit after laparoscopy and fast-track care in patients undergoing colonic surgery

    NARCIS (Netherlands)

    van Bree, Sjoerd; Vlug, Malaika; Bemelman, Willem; Hollmann, Markus; Ubbink, Dirk; Zwinderman, Koos; de Jonge, Wouter; Snoek, Susanne; Bolhuis, Karen; van der Zanden, Esmerij; The, Frans; Bennink, Roel; Boeckxstaens, Guy

    2011-01-01

    Postoperative ileus is characterized by delayed gastrointestinal (GI) transit and is a major determinant of recovery after colorectal surgery. Both laparoscopic surgery and fast-track multimodal perioperative care have been reported to improve clinical recovery. However, objective measures

  12. Does BMI influence hospital stay and morbidity after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C; Gromov, Kirill

    2016-01-01

    Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality in such pat......Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality...... in such patients who were operated with the fast-track methodology and compared the levels with those in patients with normal BMI. Patients and methods - This was a prospective observational study involving 13,730 procedures (7,194 THA and 6,536 TKA operations) performed in a standardized fast-track setting....... Complete 90-day follow-up was achieved using national registries and review of medical records. Patients were grouped according to BMI as being underweight, of normal weight, overweight, obese, very obese, and morbidly obese. Results - Median length of stay (LOS) was 2 (IQR: 2-3) days in all BMI groups. 30...

  13. First measurement of poloidal-field-induced Faraday rotation in a tokamak plasma

    International Nuclear Information System (INIS)

    Kunz, W.; Association Euratom-CEA sur la Fusion, Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92

    1978-01-01

    Faraday rotation measurements using a ferrite modulation technique were performed on one channel of the 337 μm-interferometer on TFR. The experiment is intended as a preparatory step towards poloidal-field determination on the basis of the Faraday effect in a multi-channel configuration. The technical feasibility of precise Faraday rotation measurements under machine conditions is demonstrated. The measured rotation is unambiguously due to the poloidal magnetic field and agrees fairly with what can be estimated. (author)

  14. A process model for design team communication within fast-track building projects using project websites

    NARCIS (Netherlands)

    Otter, den A.F.H.J.; Reymen, I.M.M.J.

    2008-01-01

    The factor time within building projects is on high pressure because of the increasing need for faster delivery of buildings. Within fast track, complex building projects the design process is an important key. Through case analyses offart-hack design processes it became obvious that process and

  15. Time course and reasons for 90-day mortality in fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, H

    2017-01-01

    : Prospective observational study in 13,775 consecutive THA/TKAs with similar fast-track protocols and a median length of stay of 2 days. Complete 90-days follow-up through national registries, followed by review of medical records and death certificates. Relation between mortality and surgically induced organ...

  16. Representing the Electromagnetic Field: How Maxwell's Mathematics Empowered Faraday's Field Theory

    Science.gov (United States)

    Tweney, Ryan D.

    2011-01-01

    James Clerk Maxwell "translated" Michael Faraday's experimentally-based field theory into the mathematical representation now known as "Maxwell's Equations." Working with a variety of mathematical representations and physical models Maxwell extended the reach of Faraday's theory and brought it into consistency with other…

  17. Development of Ultra-Fast Silicon Detectors for 4D tracking

    Science.gov (United States)

    Staiano, A.; Arcidiacono, R.; Boscardin, M.; Dalla Betta, G. F.; Cartiglia, N.; Cenna, F.; Ferrero, M.; Ficorella, F.; Mandurrino, M.; Obertino, M.; Pancheri, L.; Paternoster, G.; Sola, V.

    2017-12-01

    In this contribution we review the progress towards the development of a novel type of silicon detectors suited for tracking with a picosecond timing resolution, the so called Ultra-Fast Silicon Detectors. The goal is to create a new family of particle detectors merging excellent position and timing resolution with GHz counting capabilities, very low material budget, radiation resistance, fine granularity, low power, insensitivity to magnetic field, and affordability. We aim to achieve concurrent precisions of ~ 10 ps and ~ 10 μm with a 50 μm thick sensor. Ultra-Fast Silicon Detectors are based on the concept of Low-Gain Avalanche Detectors, which are silicon detectors with an internal multiplication mechanism so that they generate a signal which is factor ~10 larger than standard silicon detectors. The basic design of UFSD consists of a thin silicon sensor with moderate internal gain and pixelated electrodes coupled to full custom VLSI chip. An overview of test beam data on time resolution and the impact on this measurement of radiation doses at the level of those expected at HL-LHC is presented. First I-V and C-V measurements on a new FBK sensor production of UFSD, 50 μm thick, with B and Ga, activated at two diffusion temperatures, with and without C co-implantation (in Low and High concentrations), and with different effective doping concentrations in the Gain layer, are shown. Perspectives on current use of UFSD in HEP experiments (UFSD detectors have been installed in the CMS-TOTEM Precision Protons Spectrometer for the forward physics tracking, and are currently taking data) and proposed applications for a MIP timing layer in the HL-LHC upgrade are briefly discussed.

  18. Automatic detection of recoil-proton tracks and background rejection criteria in liquid scintillator-micro-capillary-array fast neutron spectrometer

    Science.gov (United States)

    Mor, Ilan; Vartsky, David; Dangendorf, Volker; Tittelmeier, Kai.; Weierganz, Mathias; Goldberg, Mark Benjamin; Bar, Doron; Brandis, Michal

    2018-06-01

    We describe an analysis procedure for automatic unambiguous detection of fast-neutron-induced recoil proton tracks in a micro-capillary array filled with organic liquid scintillator. The detector is viewed by an intensified CCD camera. This imaging neutron detector possesses the capability to perform high position-resolution (few tens of μm), energy-dispersive transmission-imaging using ns-pulsed beams. However, when operated with CW or DC beams, it also features medium-quality spectroscopic capabilities for incident neutrons in the energy range 2-20 MeV. In addition to the recoil proton events which display a continuous extended track structure, the raw images exhibit complex ion-tracks from nuclear interactions of fast-neutrons in the scintillator, capillaries quartz-matrix and CCD. Moreover, as expected, one also observes a multitude of isolated scintillation spots of varying intensity (henceforth denoted "blobs") that originate from several different sources, such as: fragmented proton tracks, gamma-rays, heavy-ion reactions as well as events and noise that occur in the image-intensifier and CCD. In order to identify the continuous-track recoil proton events and distinguish them from all these background events, a rapid, computerized and automatic track-recognition-procedure was developed. Based on an appropriately weighted analysis of track parameters such as: length, width, area and overall light intensity, the method is capable of distinguishing a single continuous-track recoil proton from typically surrounding several thousands of background events that are found in each CCD frame.

  19. Synchrotron Radiation and Faraday Rotation

    NARCIS (Netherlands)

    Heald, George

    2015-01-01

    Synchrotron radiation and its degree of linear polarization are powerful tracers of magnetic fields that are illuminated by cosmic ray electrons. Faraday rotation of the linearly polarized radiation is induced by intervening line-of-sight magnetic fields that are embedded in ionized plasmas. For

  20. Spouses’ involvement in older patients’ fast-track programmes during total hip replacement using case management intervention. A study protocol of the SICAM-trial

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher; Kristensson, Jimmie

    2015-01-01

    Aim To present the protocol of a two-group quasi-experimental study of spouses’ involvement through case management (The SICAM-trial) in older patients’ fast-track programmes during total hip replacement. Background Patients in fast-track programmes are required to take an active part in their tr......Aim To present the protocol of a two-group quasi-experimental study of spouses’ involvement through case management (The SICAM-trial) in older patients’ fast-track programmes during total hip replacement. Background Patients in fast-track programmes are required to take an active part...... in their treatment and rehabilitation. Spouses of older patients can often provide valued practical and emotional support, reducing stress, pain and length of stay – yet they are seldom invited to participate in a supporting role. Design A two-group quasi-experimental design with pre-test and repeated post...... and subsequently include the intervention group to avoid contamination of the control group. A case manager will be recruited to perform the case management intervention. Data will be collected from both groups at baseline, 2 weeks and 3 months after surgery. Outcome measures for patients include: functional...

  1. New Medical-School Programs Put Students on a Fast Track to the White Coat

    Science.gov (United States)

    Mangan, Katherine

    2009-01-01

    California's lieutenant governor has proposed a fast-track medical school that would shave three years off the training needed to become a physician. It is not the first time such an idea has been offered. The proposal, for a hoped-for medical school at the University of California at Merced, struck some medical educators as both unrealistic and…

  2. An assessment of the lifetime of Faraday shield elements

    International Nuclear Information System (INIS)

    Caughman, J.B.O. II; Ruzic, D.N.; Hoffman, D.J.; Langley, R.A.; Lewis, M.B.; Ryan, P.M.

    1989-01-01

    The interaction of plasma with rf fields from an ion cyclotron range of frequencies (ICRF) antenna has been studied to estimate the amount of Faraday shield erosion expected in normal ICRF heating operation. Plasma parameters and ion energies have been measured in the near field of an antenna and used in a model to estimate the erosion rate of the Faraday shield surface. Experiments were conducted on the RF Test Facility, a magnetic mirror device at Oak Ridge National Laboratory, using a single-strap resonant loop antenna with a two-tier Faraday shield. The outer tier, facing the plasma, was layered with graphite tiles. The antenna was operated at currents and voltages within 50% of those expected in tokamaks. The time-varying floating potential was measured with a capacitively coupled probe, and the time-averaged floating potential, electron temperature, and electron density were measured with Langmuir probe. Both probes were scanned in front of the antenna. Ion energies were measured with a gridded energy analyzer located below the antenna, and samples of silicon were placed on the Faraday shield surface to estimate the incident ion energy. The capacitive probe measurement show that the rf floating potential follows the magnetic field pattern of the antenna, indicating that the electromagnetic fields are responsible for the potential formation. Electron temperatures increase with rf power and can reach values ≥60 eV for an rf power of ∼25 kW. Incident ion energies ≥300 eV have been measured for the same power level. Predictions of light ion sputtering of candidate Faraday shield materials are presented. 19 refs., 6 figs., 1 tab

  3. Implementation and Performance of FPGA based track fitting for the Atlas Fast TracKer

    CERN Document Server

    Zou, Rui; The ATLAS collaboration

    2018-01-01

    The Fast TracKer (FTK) within the ATLAS trigger system provides global track reconstruction for all events passing the ATLAS Level 1 trigger by dividing the detector into parallel processing pipelines that implement pattern matching in custom integrated circuits and data routing, reduction, and parameter extraction in FPGAs. In this presentation we will describe the implementation of a critical component of the system which does partial track fitting using a method based on a principal component analysis at a rate of greater than 1 fit per 10 ps, system-wide, to reduce the output of the pattern matching. Firmware design, timing performance and preliminary results will be discussed.

  4. Position control of desiccation cracks by memory effect and Faraday waves.

    Science.gov (United States)

    Nakayama, Hiroshi; Matsuo, Yousuke; Takeshi, Ooshida; Nakahara, Akio

    2013-01-01

    Pattern formation of desiccation cracks on a layer of a calcium carbonate paste is studied experimentally. This paste is known to exhibit a memory effect, which means that a short-time application of horizontal vibration to the fresh paste predetermines the direction of the cracks that are formed after the paste is dried. While the position of the cracks (as opposed to their direction) is still stochastic in the case of horizontal vibration, the present work reports that their positioning is also controllable, at least to some extent, by applying vertical vibration to the paste and imprinting the pattern of Faraday waves, thus breaking the translational symmetry of the system. The experiments show that the cracks tend to appear in the node zones of the Faraday waves: in the case of stripe-patterned Faraday waves, the cracks are formed twice more frequently in the node zones than in the anti-node zones, presumably due to the localized horizontal motion. As a result of this preference of the cracks to the node zones, the memory of the square lattice pattern of Faraday waves makes the cracks run in the oblique direction differing by 45 degrees from the intuitive lattice direction of the Faraday waves.

  5. A two-in-one Faraday rotator mirror exempt of active optical alignment.

    Science.gov (United States)

    Wan, Qiong; Wan, Zhujun; Liu, Hai; Liu, Deming

    2014-02-10

    A two-in-one Faraday rotator mirror was presented, which functions as two independent Faraday rotation mirrors with a single device. With the introduction of a reflection lens as substitution of the mirror in traditional structure, this device is characterized by exemption of active optical alignment for the designers and manufacturers of Faraday rotator mirrors. A sample was fabricated by passive mechanical assembly. The insertion loss was measured as 0.46 dB/0.50 dB for the two independent ports, respectively.

  6. A Faraday laser lasing on Rb 1529 nm transition.

    Science.gov (United States)

    Chang, Pengyuan; Peng, Huanfa; Zhang, Shengnan; Chen, Zhangyuan; Luo, Bin; Chen, Jingbiao; Guo, Hong

    2017-08-21

    We present the design and performance characterization of a Faraday laser directly lasing on the Rb 1529 nm transition (Rb, 5P 3/2  - 4D 5/2 ) with high stability, narrow spectral linewidth and low cost. This system does not need an additional frequency-stabilized pump laser as a prerequisite to preparing Rb atom from 5S to 5P excited state. Just by using a performance-improved electrodeless discharge lamp-based excited-state Faraday anomalous dispersion optical filter (LESFADOF), we realized a heterogeneously Faraday laser with the frequency corresponding to atomic transition, working stably over a range of laser diode (LD) current from 85 mA to 171 mA and the LD temperature from 11 °C to 32 °C, as well as the 24-hour long-term frequency fluctuation range of no more than 600 MHz. Both the laser linewidth and relative intensity noisy (RIN) are measured. The Faraday laser lasing on Rb 1529 nm transition (telecom C-band) can be applied to further research on metrology, microwave photonics and optical communication systems. Besides, since the transitions correspongding to the populated excited-states of alkali atoms within lamp are extraordinarily rich, this scheme can increase the flexibility for choosing proper wavelengths for Faraday laser and greatly expand the coverage of wavelength corresponding to atomic transmission for laser frequency stabilization.

  7. Following Michael Faraday's Footprints

    Science.gov (United States)

    Galeano, Javier

    2011-01-01

    Last fall I had the good fortune of receiving financial support to shoot a documentary about Michael Faraday. I took the opportunity to learn more about this great experimentalist and to visit the highlights of places in his life. In this paper, I would like to share a list and description of some of the most remarkable places in London suitable…

  8. Nonresonant Faraday rotation in glassy semiconductors

    Science.gov (United States)

    van den Keybus, P.; Grevendonk, W.

    1986-06-01

    Nonresonant interband Faraday rotation in amorphous semiconductors, as a function of photon energy, may be described by an equation derived for direct transitions in crystalline semiconductors. In this paper it is shown how this equation may be obtained for the former case also, assuming a parabolic density of states function N(E) and a correlation between valence- and conduction-band states. The analysis of experiments on chalcogenide glasses reveals a Faraday-rotation energy gap EFRg that is significantly larger than the optical gap Eoptg. The effect is attributed to transitions between extended states, so that it is meaningful to compare EFRg with the mobility gap Eμg. For oxide glasses both gaps are comparable but for chalcogenide glasses EFRg is too large by a few tenths of 1 eV.

  9. Inverse Faraday effect with plasmon beams

    International Nuclear Information System (INIS)

    Ali, S; Mendonca, J T

    2011-01-01

    The angular momentum conservation equation is considered for an electron gas, in the presence of Laguerre-Gaussian (LG) plasmons propagating along the z-axis. The LG plasmons carry a finite orbital angular momentum despite longitudinal nature, which can be partly transfered to the electrons. For short timescales, such that ion motion can be neglected, plasmons primarily interact with the electrons, creating an azimuthal electric field and generating an axial magnetic field. This effect can be called an inverse Faraday effect due to plasmons. Numerically, it is found that the magnitude of the magnetic field enhances with the plasmon density or with the energy of the electron plasma waves. A comparison of the magnitudes of the axial magnetic field is made for the inverse Faraday effect excited by both plasmons and transverse photons.

  10. CRADA Final Report, 2011S003, Faraday Technologies

    International Nuclear Information System (INIS)

    Faraday Technologies

    2012-01-01

    This Phase I SBIR program addressed the need for an improved manufacturing process for electropolishing niobium RF superconducting cavities for the International Linear Collider (ILC). The ILC is a proposed particle accelerator that will be used to gain a deeper understanding of the forces of energy and matter by colliding beams of electrons and positrons at nearly the speed of light. The energy required for this to happen will be achieved through the use of advanced superconducting technology, specifically ∼16,000 RF superconducting cavities operating at near absolute zero. The RF superconductor cavities will be fabricated from highly pure Nb, which has an extremely low surface resistance at 2 Kelvin when compared to other materials. To take full advantage of the superconducting properties of the Nb cavities, the inner surface must be a) polished to a microscale roughness < 0.1 µm with removal of at least 100 µm of material, and b) cleaned to be free of impurities that would degrade performance of the ILC. State-of-the-art polishing uses either chemical polishing or electropolishing, both of which require hydrofluoric acid to achieve breakdown of the strong passive film on the surface. In this Phase I program, Faraday worked with its collaborators at the Thomas Jefferson National Accelerator Facility (JLab) to demonstrate the feasibility of an electropolishing process for pure niobium, utilizing an environmentally benign alternative to chemical or electrochemical polishing electrolytes containing hydrofluoric acid. Faraday utilized a 31 wt% aqueous sulfuric acid solution (devoid of hydrofluoric acid) in conjunction with the FARADAYICSM Process, which uses pulse/pulse reverse fields for electropolishing, to demonstrate the ability to electropolish niobium to the desired surface finish. The anticipated benefits of the FARADAYICSM Electropolishing process will be a simpler, safer, and less expensive method capable of surface finishing high purity niobium cavities

  11. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    Science.gov (United States)

    Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith

    2013-05-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.

  12. Inverse Faraday Effect Revisited

    Science.gov (United States)

    Mendonça, J. T.; Ali, S.; Davies, J. R.

    2010-11-01

    The inverse Faraday effect is usually associated with circularly polarized laser beams. However, it was recently shown that it can also occur for linearly polarized radiation [1]. The quasi-static axial magnetic field by a laser beam propagating in plasma can be calculated by considering both the spin and the orbital angular momenta of the laser pulse. A net spin is present when the radiation is circularly polarized and a net orbital angular momentum is present if there is any deviation from perfect rotational symmetry. This orbital angular momentum has recently been discussed in the plasma context [2], and can give an additional contribution to the axial magnetic field, thus enhancing or reducing the inverse Faraday effect. As a result, this effect that is usually attributed to circular polarization can also be excited by linearly polarized radiation, if the incident laser propagates in a Laguerre-Gauss mode carrying a finite amount of orbital angular momentum.[4pt] [1] S. ALi, J.R. Davies and J.T. Mendonca, Phys. Rev. Lett., 105, 035001 (2010).[0pt] [2] J. T. Mendonca, B. Thidé, and H. Then, Phys. Rev. Lett. 102, 185005 (2009).

  13. Faraday Cage Protects Against Lightning

    Science.gov (United States)

    Jafferis, W.; Hasbrouck, R. T.; Johnson, J. P.

    1992-01-01

    Faraday cage protects electronic and electronically actuated equipment from lightning. Follows standard lightning-protection principles. Whether lightning strikes cage or cables running to equipment, current canceled or minimized in equipment and discharged into ground. Applicable to protection of scientific instruments, computers, radio transmitters and receivers, and power-switching equipment.

  14. Diagnose of large area electron beam with faraday cup

    International Nuclear Information System (INIS)

    Tang Ying; Qian Hang; Yi Aiping; Huang Xin; Yu Li; Liu Jingru; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2008-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. This paper introduces Faraday cup is used in the diagnose experiment on the uniformity of large area e-beam generated by SPG-200 pulsed power generator. Construction of Faraday cup and the results of calibration are presented in detail. The uniformity of velvet emission is given, and the results of experiment are analyzed. (authors)

  15. Faraday-Shielded dc Stark-Shift-Free Optical Lattice Clock

    Science.gov (United States)

    Beloy, K.; Zhang, X.; McGrew, W. F.; Hinkley, N.; Yoon, T. H.; Nicolodi, D.; Fasano, R. J.; Schäffer, S. A.; Brown, R. C.; Ludlow, A. D.

    2018-05-01

    We demonstrate the absence of a dc Stark shift in an ytterbium optical lattice clock. Stray electric fields are suppressed through the introduction of an in-vacuum Faraday shield. Still, the effectiveness of the shielding must be experimentally assessed. Such diagnostics are accomplished by applying high voltage to six electrodes, which are grounded in normal operation to form part of the Faraday shield. Our measurements place a constraint on the dc Stark shift at the 10-20 level, in units of the clock frequency. Moreover, we discuss a potential source of error in strategies to precisely measure or cancel nonzero dc Stark shifts, attributed to field gradients coupled with the finite spatial extent of the lattice-trapped atoms. With this consideration, we find that Faraday shielding, complemented with experimental validation, provides both a practically appealing and effective solution to the problem of dc Stark shifts in optical lattice clocks.

  16. The Faraday effect of an antiferromagnetic photonic crystal with a defect layer

    International Nuclear Information System (INIS)

    Wang Xuanzhang

    2005-01-01

    A theoretical calculation of the Faraday optical rotation effect of an antiferromagnetic (AF) photonic crystal is presented. This crystal is composed of AF and dielectric (D) layers and contains an AF defect layer. From the theoretical results for the FeF 2 -SiO 2 crystal, we see a defect mode with high transmission and a high Faraday rotation angle in the optical stop band for ω/2πc -1 . The Faraday rotation of the mode is about 28 deg. mm -1 and 15 times that of the single AF film. Another more striking property is that the rotation in the vicinity of the zero-field AF resonance frequency is even larger than that of the defect mode: about 250 times. The Faraday rotation can be tuned by changing the strength of the external static magnetic field

  17. Faraday effect on stimulated Raman scattering in the linear region

    Science.gov (United States)

    Liu, Z. J.; Li, B.; Xiang, J.; Cao, L. H.; Zheng, C. Y.; Hao, L.

    2018-04-01

    The paper presents the effect of Faraday rotation on stimulated Raman scattering (SRS). When light propagates along the magnetic field upon plasma, Faraday rotation occurs. The rotation angle can be expressed as {{d}}θ /{{d}}{s}=2.93× {10}-4B\\tfrac{{n}e/{n}c}{\\sqrt{1-{n}e/{n}c}} {cm}}-1 approximately, where θ is the rotation angle and s is distance, n e is the electron density, n c is the critical density and B is magnetic field in unit of Gauss. Both the incident light and Raman light have Faraday effects. The angle between the polarization directions of incident light and Raman light changes with position. The driven force of electron plasma wave also reduces, and then SRS scattering level is reduced. Faraday rotation effect can increase the laser intensity threshold of Raman scattering, even if the magnetic field strength is small. The circularly polarized light incident case is also compared with that of the linearly polarized light incident. The Raman scattering level of linearly polarized light is much smaller than that of circularly polarized light in the magnetized plasma. The difference between linearly and circularly polarized lights is also discussed.

  18. Fast neutron detection using solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Vilela, E.C.

    1990-01-01

    CR-39 and Makrofol-E solid state nuclear track detectors were studied aiming their application to fast neutron detection. Optimum etching conditions of those two kinds of materials were determined the followings - the Makrofol-E detector is electrochemically etched in a PEW solution (15% KOH, 40% ethilic alcohol and 45% water) for 2 h., with an applied electric field strength of 30 kV/cm (r/m/s/) and frequency of 2 kHz, at room temperature; - the CR-39 detector is chemically pre-etched during 1 h in a 20% (w/v) NaOH solution at 70 sup(0)C, followed by 13 h electrochemical etch using the same solution at room temperature and an electric field strength of 30 kV/cm (r.m.s.) and frequency of 2 kHz.(E.G.)

  19. Faraday waves in a Hele-Shaw cell

    Science.gov (United States)

    Li, Jing; Li, Xiaochen; Chen, Kaijie; Xie, Bin; Liao, Shijun

    2018-04-01

    We investigate Faraday waves in a Hele-Shaw cell via experimental, numerical, and theoretical studies. Inspired by the Kelvin-Helmholtz-Darcy theory, we develop the gap-averaged Navier-Stokes equations and end up with the stable standing waves with half frequency of the external forced vibration. To overcome the dependency of a numerical model on the experimental parameter of wave length, we take two-phase flow into consideration and a novel dispersion relation is derived. The numerical results compare well with our experimental data, which effectively validates our proposed mathematical model. Therefore, this model can produce robust solutions of Faraday wave patterns and resolve related physical phenomena, which demonstrates the practical importance of the present study.

  20. Preoperative prediction of potentially preventable morbidity after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Petersen, Morten Aa; Kehlet, Henrik

    2016-01-01

    . DESIGN: Prospective observational study. SETTING: Elective primary unilateral total hip and knee arthroplasty with prospectively collected preoperative patient characteristics; similar standardised fast-track protocols; evaluation of complications through discharge and medical records; and complete 90...... days follow-up through nationwide databases. PARTICIPANTS: 8373 consecutive unselected total hip arthroplasty (THA) and knee arthroplasty from January 2010 to November 2012. RESULTS: There were 557 procedures (6.4%) followed by potentially preventable complications resulting in hospitalisation >4 days...

  1. A Fast Track approach to deal with the temporal dimension of crop water footprint

    Science.gov (United States)

    Tuninetti, Marta; Tamea, Stefania; Laio, Francesco; Ridolfi, Luca

    2017-07-01

    Population growth, socio-economic development and climate changes are placing increasing pressure on water resources. Crop water footprint is a key indicator in the quantification of such pressure. It is determined by crop evapotranspiration and crop yield, which can be highly variable in space and time. While the spatial variability of crop water footprint has been the objective of several investigations, the temporal variability remains poorly studied. In particular, some studies approached this issue by associating the time variability of crop water footprint only to yield changes, while considering evapotranspiration patterns as marginal. Validation of this Fast Track approach has yet to be provided. In this Letter we demonstrate its feasibility through a comprehensive validation, an assessment of its uncertainty, and an example of application. Our results show that the water footprint changes are mainly driven by yield trends, while evapotranspiration plays a minor role. The error due to considering constant evapotranspiration is three times smaller than the uncertainty of the model used to compute the crop water footprint. These results confirm the suitability of the Fast Track approach and enable a simple, yet appropriate, evaluation of time-varying crop water footprint.

  2. The use of a break-even analysis: financial analysis of a fast-track program.

    Science.gov (United States)

    Saywell, R M; Cordell, W H; Nyhuis, A W; Giles, B K; Culler, S D; Woods, J R; Chu, D K; McKinzie, J P; Rodman, G H

    1995-08-01

    To calculate the financial break-even point and illustrate how changes in third-party reimbursement and eligibility could affect a program's fiscal standing. Demographic, clinical, and financial data were collected retrospectively for 446 patients treated in a fast-track program during June 1993. The fast-track program is located within the confines of the emergency medicine and trauma center at a 1,050-bed tertiary care Midwestern teaching hospital and provides urgent treatment to minimally ill patients. A financial break-even analysis was performed to determine the point where the program generated enough revenue to cover its total variable and fixed costs, both direct and indirect. Given the relatively low average collection rate (62%) and high percentage of uninsured patients (31%), the analysis showed that the program's revenues covered its direct costs but not all of the indirect costs. Examining collection rates or payer class mix without examining both costs and revenues may lead to an erroneous conclusion about a program's fiscal viability. Sensitivity analysis also shows that relatively small changes in third-party coverage or eligibility (income) requirements can have a large impact on the program's financial solvency and break-even volumes.

  3. Graphite-ceramic rf Faraday-thermal shield and plasma limiter

    Science.gov (United States)

    Hwang, D.L.Q.; Hosea, J.C.

    1983-05-05

    The present invention is directed to a brazing procedure for joining a ceramic or glass material (e.g., Al/sub 2/O/sub 3/ or Macor) to graphite. In particular, the present invention is directed to a novel brazing procedure for the production of a brazed ceramic graphite product useful as a Faraday shield. The brazed ceramic graphite Faraday shield of the present invention may be used in Magnetic Fusion Devices (e.g., Princeton Large Torus Tokamak) or other high temperature resistant apparatus.

  4. Reconfigurable Patch Antenna Radiations Using Plasma Faraday Shield Effect

    OpenAIRE

    Barro , Oumar Alassane; Himdi , Mohamed; Lafond , Olivier

    2016-01-01

    International audience; This letter presents a new reconfigurable antenna associated with a plasma Faraday shield effect. The Faraday shield effect is realized by using a fluorescent lamp. A patch antenna operating at 2.45 GHz is placed inside the lamp. The performance of the reconfigurable system is observed in terms of S11, gain and radiation patterns by simulation and measurement. It is shown that by switching ON the fluorescent lamp, the gain of the antenna decreases and the antenna syste...

  5. Improving the quality of pretreatment staging in patients with esophageal carcinoma - a fast track study

    Energy Technology Data Exchange (ETDEWEB)

    Didden, Paul; Spaander, Manon C. W.; Kuipers, Ernst J.; Bruno, Marco J. (Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam (Netherlands)), E-mail: v.spaander@erasmusmc.nl; Wijnhoven, Bas P. L. (Department of Surgery, Erasmus University Medical Center, Rotterdam (Netherlands))

    2012-03-15

    Background: Current guidelines for esophageal cancer recommend series of diagnostic investigations to determine pretreatment TNM stage. When investigations are done sequentially, diagnostic work-up time may be prolonged considerably. Aim of the study was to determine the feasibility and efficacy of a fast track staging strategy within five days after the first consultation. Material and methods: Between 2007 and 2010 all patients presenting with esophageal cancer at the Department of Gastroenterology in a tertiary referral center were prospectively analyzed. At Day 1 all patients underwent computed tomography (CT), endoscopic ultrasound (EUS) and ultrasonography of the neck (United States). Results and treatment implications were discussed within a multidisciplinary meeting. This fast track strategy was considered completed successfully if pre-treatment TNM classification was achieved and therapy was proposed to the patient at the outpatient clinic at Day five. In those cases where staging period time was prolonged, the number and type of additional tests were documented including the ensuing time delay. Results: In 111 patients CT, EUS and US were performed in 100%, 88.3% and 97.3% respectively. A final TNM stage and treatment proposal was reached at Day 5 in 60% of the patients. Additional tests were diverse and mainly used to prove local irresectability or presence of distant metastasis. Multivariate analysis identified presence of lymphadenopathy (HR 0.25 p 0.03) and metastasis (HR 0.27 p = 0.03) as significant predictors of not completing the staging period within five days. In 18% of patients overuse of at least one test occurred, most commonly because CT already revealed distant metastasis. Conclusion: Employment of a fast track five day staging strategy in patients with esophageal carcinoma is feasible. Definite TNM stage and treatment proposal can be achieved in 60% of cases, but comes at the expense of test overuse in about one fifth of patients

  6. Building a better Faraday cage

    Science.gov (United States)

    MartinAlfven; Wright, David; skocpol; Rounce, Graham; Richfield, Jon; W, Nick; wheelsonfire

    2015-11-01

    In reply to the physicsworld.com news article “Are Faraday cages less effective than previously thought?” (15 September, http://ow.ly/SfklO), about a study that indicated, based on mathematical modelling, that conducting wire-mesh cages may not be as good at excluding electromagnetic radiation as is commonly assumed.

  7. Shot-noise-limited optical Faraday polarimetry with enhanced laser noise cancelling

    International Nuclear Information System (INIS)

    Li, Jiaming; Luo, Le; Carvell, Jeff; Cheng, Ruihua; Lai, Tianshu; Wang, Zixin

    2014-01-01

    We present a shot-noise-limited measurement of optical Faraday rotations with sub-ten-nanoradian angular sensitivity. This extremely high sensitivity is achieved by using electronic laser noise cancelling and phase sensitive detection. Specially, an electronic laser noise canceller with a common mode rejection ratio of over 100 dB was designed and built for enhanced laser noise cancelling. By measuring the Faraday rotation of ambient air, we demonstrate an angular sensitivity of up to 9.0×10 −9  rad/√(Hz), which is limited only by the shot-noise of the photocurrent of the detector. To date, this is the highest angular sensitivity ever reported for Faraday polarimeters in the absence of cavity enhancement. The measured Verdet constant of ambient air, 1.93(3)×10 −9 rad/(G cm) at 633 nm wavelength, agrees extremely well with the earlier experiments using high finesse optical cavities. Further, we demonstrate the applications of this sensitive technique in materials science by measuring the Faraday effect of an ultrathin iron film

  8. Nonlinear pattern formation of Faraday waves

    NARCIS (Netherlands)

    Binks, D.J.; Water, van de W.

    1997-01-01

    A cascade of surface wave patterns with increasing rotational symmetry ranging from simple square to tenfold quasiperiodic is observed for Faraday waves. The experiment concerns the excitation of subharmonic standing surface waves by oscillating vertical acceleration. Our observation agrees with the

  9. Temperature dependence of the Faraday rotation for CdMnCoTe films

    International Nuclear Information System (INIS)

    Ahn, J. Y.; Tanaka, M.; Imamura, M.

    2001-01-01

    The temperature dependence of magneto-optical property in the visible wavelength region has been studied on four-element semimagnetic semiconductor CdMnCoTe films deposited on quartz glass substrates by using MBE equipment. A large dispersion of Faraday rotation was observed, and the peak of the Faraday rotation was shifted to the higher photon energies with increasing Mn concentration at low temperatures. At 180 K, the value of the Faraday rotation observed for the Cd 0.647 Mn 0.34 Co 0.013 Te film on quartz glass was -0.36 deg/cmG at 630 nm. It is equivalent to the value of -0.36 deg/cmG observed at 77 K for the Cd 0.52 Mn 0.48 Te film on quartz glass. At 77 K, the Faraday rotation observed for the Cd 0.647 Mn 0.34 Co 0.013 Te film on quartz glass was -0.49 deg/cmG at 610 nm. The value is approximately two times larger than that of the Cd 0.52 Mn 0.48 Te film deposited on the same quartz glass substrate. The origin of the enhancement of Faraday rotation in CdMnCoTe films has been discussed in terms of the magnetic susceptibility χ. [copyright] 2001 American Institute of Physics

  10. Hardware realization of a fast neural network algorithm for real-time tracking in HEP experiments

    International Nuclear Information System (INIS)

    Leimgruber, F.R.; Pavlopoulos, P.; Steinacher, M.; Tauscher, L.; Vlachos, S.; Wendler, H.

    1995-01-01

    A fast pattern recognition system for HEP experiments, based on artificial neural network algorithms (ANN), has been realized with standard electronics. The multiplicity and location of tracks in an event are determined in less than 75 ns. Hardware modules of this first level trigger were extensively tested for performance and reliability with data from the CPLEAR experiment. (orig.)

  11. Faraday rotation enhancement of gold coated Fe2O3 nanoparticles: comparison of experiment and theory.

    Science.gov (United States)

    Dani, Raj Kumar; Wang, Hongwang; Bossmann, Stefan H; Wysin, Gary; Chikan, Viktor

    2011-12-14

    Understanding plasmonic enhancement of nanoscale magnetic materials is important to evaluate their potential for application. In this study, the Faraday rotation (FR) enhancement of gold coated Fe(2)O(3) nanoparticles (NP) is investigated experimentally and theoretically. The experiment shows that the Faraday rotation of a Fe(2)O(3) NP solution changes from approximately 3 rad/Tm to 10 rad/Tm as 5 nm gold shell is coated on a 9.7 nm Fe(2)O(3) core at 632 nm. The results also show how the volume fraction normalized Faraday rotation varies with the gold shell thickness. From the comparison of experiment and calculated Faraday rotation based on the Maxwell-Garnett theory, it is concluded that the enhancement and shell dependence of Faraday rotation of Fe(2)O(3) NPs is a result of the shifting plasmon resonance of the composite NP. In addition, the clustering of the NPs induces a different phase lag on the Faraday signal, which suggests that the collective response of the magnetic NP aggregates needs to be considered even in solution. From the Faraday phase lag, the estimated time of the full alignment of the magnetic spins of bare (cluster size 160 nm) and gold coated NPs (cluster size 90 nm) are found to be 0.65 and 0.17 μs. The calculation includes a simple theoretical approach based on the Bruggeman theory to account for the aggregation and its effect on the Faraday rotation. The Bruggeman model provides a qualitatively better agreement with the experimentally observed Faraday rotation and points out the importance of making a connection between component properties and the average "effective" optical behavior of the Faraday medium containing magnetic nanoparticles. © 2011 American Institute of Physics

  12. Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    Science.gov (United States)

    Miranda, Alan; Staelens, Steven; Stroobants, Sigrid; Verhaeghe, Jeroen

    2017-07-01

    To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET point sources (3-4) attached to the rat's head are tracked in image space using 15-32-ms time frames. Our point source tracking (PST) method was validated using a manually moved microDerenzo phantom that was simultaneously tracked with an optical tracker (OT) for comparison. The PST method was further validated in three awake [ 18 F]FDG rat brain scans. Compared with the OT, the PST-based correction at the same frame rate (31.2 Hz) reduced the reconstructed FWHM by 0.39-0.66 mm for the different tested rod sizes of the microDerenzo phantom. The FWHM could be further reduced by another 0.07-0.13 mm when increasing the PST frame rate (66.7 Hz). Regional brain [ 18 F]FDG uptake in the motion corrected scan was strongly correlated ( ) with that of the anesthetized reference scan for all three cases ( ). The proposed PST method allowed excellent and reproducible motion correction in awake in vivo experiments. In addition, there is no need of specialized tracking equipment or additional calibrations to be performed, the point sources are practically imperceptible to the rat, and PST is ideally suitable for small bore scanners, where optical tracking might be challenging.

  13. Faraday's Law and Seawater Motion

    Science.gov (United States)

    De Luca, R.

    2010-01-01

    Using Faraday's law, one can illustrate how an electromotive force generator, directly utilizing seawater motion, works. The conceptual device proposed is rather simple in its components and can be built in any high school or college laboratory. The description of the way in which the device generates an electromotive force can be instructive not…

  14. The Effects of the Fast Track Preventive Intervention on the Development of Conduct Disorder across Childhood

    Science.gov (United States)

    Child Development, 2011

    2011-01-01

    The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social…

  15. La electricidad antes de Faraday. Parte 2

    Directory of Open Access Journals (Sweden)

    Gabriel Poveda Ramos

    2004-01-01

    Full Text Available Esta es la segunda y última parte de este artículo, cuya primera parte fue publicada en el número anterior de esta revista. Esta parte cubre el período de la Edad Moderna posterior al Renacimiento, hasta llegar a Faraday. Presenta los descubrimientos y los inventos que en este tramo de historia se hicieron en la teoría y en la experimentación en el campo de la electricidad, los cuales forman parte muy importante de esa ciencia, con el nombre de electrostática. Esta parte final (y el artículo completo llegan hasta Faraday porque este gran científico reunió en un solo cuerpo de conocimientos la electricidad y el magnetismo.

  16. Faraday Rotator 5 kV Capacitor Bank

    International Nuclear Information System (INIS)

    Fetterman, C.C.

    1975-01-01

    A Faraday rotator 5 kV capacitor bank is a pulsed output power supply used to energize Faraday rotators for optical isolation in the ''LLL kJ Glass Laser System.'' Each supply contains either one, two or three parallel 240 μF storage capacitors depending on the size of the isolator used. Generally, the ''A*''(216 μH) isolator is energized with one capacitor, the ''A''(116 μH) isolator uses two capacitors and the ''B''(87 μH) isolator requires three capacitors. All models of isolators have been tested with four capacitors under maximum voltage and 25 feet of RG-217 cable with no hazardous effects. Except for the number of capacitors in each unit, the supplies are otherwise physically identical

  17. Faraday instability in deformable domains

    International Nuclear Information System (INIS)

    Pucci, G.

    2013-01-01

    Hydrodynamical instabilities are usually studied either in bounded regions or free to grow in space. In this article we review the experimental results of an intermediate situation, in which an instability develops in deformable domains. The Faraday instability, which consists in the formation of surface waves on a liquid experiencing a vertical forcing, is triggered in floating liquid lenses playing the role of deformable domains. Faraday waves deform the lenses from the initial circular shape and the mutual adaptation of instability patterns with the lens boundary is observed. Two archetypes of behaviour have been found. In the first archetype a stable elongated shape is reached, the wave vector being parallel to the direction of elongation. In the second archetype the waves exceed the response of the lens border and no equilibrium shape is reached. The lens stretches and eventually breaks into fragments that have a complex dynamics. The difference between the two archetypes is explained by the competition between the radiation pressure the waves exert on the lens border and its response due to surface tension.

  18. Relatives in older patients' fast-track treatment programme during total hip or knee replacement. A grounded theory study

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher

    and considerate support in concern for the patients; Substituting mode, with practical and cognitive support; and Adapting mode, by trying to fit in with the patients’ and health professionals’ requirements. Study II: 16 patients aged 70 to 94 were included and data was collected through 15 non......The aim of this Ph.D.-dissertation was to generate grounded theories of relatives, patients, and health professionals’ pattern of behaviour, respectively, in relation to the relatives of older patients’ fast-track treatment programmes during total hip or knee replacement. The dissertation includes...... to the older patients’ self-determination of being autonomous and how they adapt and are perceived in the health professionals’ environment. This may be useful to the health professionals in orthopaedic fast-track treatment programmes and their future collaboration with older patients and their relatives....

  19. Role of preoperative anemia for risk of transfusion and postoperative morbidity in fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jans, Øivind; Jørgensen, Christoffer; Kehlet, Henrik

    2014-01-01

    BACKGROUND: Preoperative anemia has been associated with increased risk of allogeneic blood transfusion and postoperative morbidity and mortality. The prevalence of preoperative anemia and its association with postoperative outcomes has not previously been reported in relation to fast......-track elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). We aimed to evaluate the prevalence of preoperative anemia in elective fast-track THA and TKA and its association with risk of perioperative transfusion, prolonged length of hospital stay (LOS), and postoperative readmission. STUDY...... national databases and patient charts. Adjusted risk estimates for transfusion, prolonged LOS, and all-cause readmission according to preoperative anemia status were obtained by multivariate logistic regression. RESULTS: A total of 5.165 THA or TKA procedures were included with a mean patient age of 67...

  20. Nursing in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    must still focus on the individual patient. Nurses need to have enough education to manage the complex tasks and increased responsibility. To prevent undesirable outcomes in the future, there is a need to pay attention to the nursing quality in balance with the nursing budget. It may, therefore......AIM: To describe the increased activity in total hip arthroplasty (THA) and total knee arthroplasty (TKA) from 2002 to 2012 in a single orthopaedic department, the organisation of fast-track and its consequences for nursing care. METHODS: Retrospective, descriptive design. Data collection; from...... gained tasks from surgeons and physiotherapists and thus gained more responsibility, for example, for pain management and mobilisation. Staffing levels in the ward in 2002 and 2012 were almost unchanged; 16.0 and 15.8 respectively. Nurses were undertaking more complicated tasks. CONCLUSION: Nursing care...

  1. Sleep disturbances after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, L; Jennum, P; Kehlet, H

    2012-01-01

    BACKGROUND: /st>Major surgery is followed by pronounced sleep disturbances after traditional perioperative care potentially leading to prolonged recovery. The aim was to evaluate the rapid eye movement (REM) sleep duration and sleep architecture before and after fast-track hip and knee replacement......, and on the fourth postoperative night at home. Sleep staging was performed according to the American Academy of Sleep Medicine manual. Opioid use, pain, and inflammatory response (C-reactive protein) were also evaluated. RESULTS: /st>The mean LOS was 1.5 (1-2) days. The mean REM sleep time decreased from a mean...... on the fourth postoperative night. There was no association between opioid use, pain scores, and inflammatory response with a disturbed sleep pattern. CONCLUSIONS: /st>Despite ultra-short LOS and provision of spinal anaesthesia with multimodal opioid-sparing analgesia, REM sleep was almost eliminated...

  2. Polycrystalline (TbXY1-X)2O3 Faraday rotator.

    Science.gov (United States)

    Ikesue, Akio; Aung, Yan Lin; Makikawa, Shinji; Yahagi, Akira

    2017-11-01

    We have succeeded for the first time in synthesizing an optical grade (Tb X Y 1-X ) 2 O 3 (X=0.5-1.0) ceramic Faraday rotator, which greatly exceeds the basic characteristics of the commercial terbium gallium garnet (TGG) (Tb 3 Ga 5 O 12 ) crystal. The Faraday rotation angle increased as the Tb concentration increased, and the Verdet constant increased from 2.1 (82  rad T -1  m -1 at X=0.5) to 3.8 times (154  rad T -1  m -1 at X=1.0) than the TGG single crystal, which is regarded as highest class. Therefore, it is possible to minimize the Faraday rotator length and the magnet in building an optical isolator. It was also confirmed that its optical quality was very comparable to the commercial TGG crystal.

  3. Ramsey-CPT spectrum with the Faraday effect and its application to atomic clocks

    International Nuclear Information System (INIS)

    Tian Yuan; Gu Si-Hong; Tan Bo-Zhong; Yang Jing; Zhang Yi

    2015-01-01

    A method that obtains the Ramsey-coherent population trapping (CPT) spectrum with the Faraday effect is investigated. An experiment is implemented to detect the light polarization components generated from the Faraday effect. The experimental results agree with the theoretical calculations based on the Liouville equation. By comparing with the method without using the Faraday effect, the potential of this method for a CPT-based atomic clock is assessed. The results indicate that this method should improve the short-term frequency stability by several times. (paper)

  4. Differential detection for measurements of Faraday rotation by means of ac magnetic fields

    International Nuclear Information System (INIS)

    Valev, V K; Wouters, J; Verbiest, T

    2008-01-01

    We demonstrate that by using a combination of a Wollaston prism and two photodiodes the accuracy in the measurements of Faraday rotation with ac magnetic fields can be greatly improved. Our experiments were performed on microscope cover glass plates with thicknesses between 0.13 and 0.16 mm. We show that our setup is capable of distinguishing between the Faraday rotation signals of glass plates having a difference in thickness of a few micrometers, corresponding to Faraday rotations of hundreds of microdegrees per Tesla only

  5. Faraday waves in quasi-one-dimensional superfluid Fermi-Bose mixtures

    DEFF Research Database (Denmark)

    Abdullaev, F. Kh.; Ögren, Magnus; Sørensen, Mads Peter

    2013-01-01

    The generation of Faraday waves in superfluid Fermi-Bose mixtures in elongated traps is investigated. The generation of waves is achieved by periodically changing a parameter of the system in time. Two types of modulations of parameters are considered: a variation of the fermion-boson scattering...... length and the boson-boson scattering length. We predict the properties of the generated Faraday patterns and study the parameter regions where they can be excited....

  6. First results of the silicon telescope using an 'artificial retina' for fast track finding

    Energy Technology Data Exchange (ETDEWEB)

    Neri, N. [Istituto Nazionale di Fisica Nucleare - INFN, Sezione di Milano, Milano (Italy); Abba, A.; Caponio, F.; Geraci, A.; Grizzuti, M.; Lusardi, N. [INFN Milano and Politecnico di Milano, Milano (Italy); Citterio, M.; Coelli, S.; Fu, J.; Monti, M.; Petruzzo, M. [INFN Milano, Milano (Italy); Bedeschi, F.; Ninci, D.; Piucci, A.; Spinella, F.; Walsh, J. [INFN Pisa, Pisa (Italy); Cenci, R.; Marino, P.; Morello, M. J.; Stracka, S. [INFN Pisa and Scuola Normale Superiore di Pisa, Pisa (Italy); Punzi, G. [INFN Pisa and Universita di Pisa, Pisa (Italy); Tonelli, D. [CERN, Geneva (Switzerland); Ristori, L. [INFN Pisa, Pisa (Italy); Fermilab, Batavia, Illinois (United States)

    2015-07-01

    We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecture is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)

  7. A Mobile Phone Faraday Cage

    Science.gov (United States)

    French, M. M. J.

    2011-01-01

    A Faraday cage is an interesting physical phenomenon where an electromagnetic wave can be excluded from a volume of space by enclosure with an electrically conducting material. The practical application of this in the classroom is to block the signal to a mobile phone by enclosing it in a metal can. The background of the physics behind this is…

  8. Various Paths to Faraday's Law

    Science.gov (United States)

    Redzic, Dragan V.

    2008-01-01

    In a recent note, the author presented a derivation of Faraday's law of electromagnetic induction for a closed filamentary circuit C(t) which is moving at relativistic velocities and also changing its shape as it moves via the magnetic vector potential. Recently, Kholmetskii et al, while correcting an error in an equation, showed that it can be…

  9. A "package solution" fast track program can reduce the diagnostic waiting time in head and neck cancer

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Johansen, Jørgen; Gano, Lars

    2014-01-01

    and Neck Surgery during three comparable time intervals 2006-2007, 2007-2008, and 2011-2012 (groups 1-3) were investigated. We recorded the time from patient referral, to first consultation and final diagnosis. The first interval was before initiation of the "package solution", the second just after......In 2007, a fast track program for patients with suspicion of head and neck cancer (HNC) was introduced in Denmark to reduce unnecessary waiting time. The program was based on so called "package solutions" including pre-booked slots for outpatient evaluation, imaging, and diagnostic surgical...... procedures. The purpose of this study is to present a model for fast track handling of patients suspicious of cancer in the head and neck region and to evaluate the effect of implementation on the diagnostic work up time. Patients with suspicion of HNC referred to the same university department of ENT Head...

  10. ICRF Faraday shield plasma sheath models: Low and high conductivity limits

    International Nuclear Information System (INIS)

    Whealton, J.H.; Ryan, P.M.; Raridon, R.J.

    1989-01-01

    Using a 2-D nonlinear formulation which explicitly considers the plasma edge near a Faraday shield in a self consistent manner, progress is indicated in the modeling of the ion motion for a Faraday shield concept and model suggested by Perkins. Several models are considered which may provide significant insight into the impurities generation for ICRH antennas. 6 refs., 8 figs

  11. Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Kehlet, Henrik

    2012-01-01

    Bandholm T, Kehlet H. Physiotherapy exercise after fast-track total hip and knee arthroplasty: time for reconsideration? Major surgery, including total hip arthroplasty (THA) and total knee arthroplasty (TKA), is followed by a convalescence period, during which the loss of muscle strength......-track methodology or enhanced recovery programs. It is the nature of this methodology to systematically and scientifically optimize all perioperative care components, with the overall goal of enhancing recovery. This is also the case for the care component "physiotherapy exercise" after THA and TKA. The 2 latest...... meta-analyses on the effectiveness of physiotherapy exercise after THA and TKA generally conclude that physiotherapy exercise after THA and TKA either does not work or is not very effective. The reason for this may be that the "pill" of physiotherapy exercise typically offered after THA and TKA does...

  12. The contributions of Faraday and Maxwell to electrical science

    CERN Document Server

    Tricker, R A R

    1966-01-01

    The Contributions of Faraday and Maxwell to Electrical Science deals with the development of electromagnetic theory following the establishment of the basis for the first law of circulation relating to the magnetic fields generated by steady currents. This book is organized into two parts encompassing nine chapters that specifically treat the provision of the basis for the second law of circulation, the law that deals with the induction of currents, which was predominantly the work of British physicists, Michael Faraday and James Clerk Maxwell. Part I highlights their life, career, and contri

  13. Linear theory on temporal instability of megahertz faraday waves for monodisperse microdroplet ejection.

    Science.gov (United States)

    Tsai, Shirley C; Tsai, Chen S

    2013-08-01

    A linear theory on temporal instability of megahertz Faraday waves for monodisperse microdroplet ejection based on mass conservation and linearized Navier-Stokes equations is presented using the most recently observed micrometer- sized droplet ejection from a millimeter-sized spherical water ball as a specific example. The theory is verified in the experiments utilizing silicon-based multiple-Fourier horn ultrasonic nozzles at megahertz frequency to facilitate temporal instability of the Faraday waves. Specifically, the linear theory not only correctly predicted the Faraday wave frequency and onset threshold of Faraday instability, the effect of viscosity, the dynamics of droplet ejection, but also established the first theoretical formula for the size of the ejected droplets, namely, the droplet diameter equals four-tenths of the Faraday wavelength involved. The high rate of increase in Faraday wave amplitude at megahertz drive frequency subsequent to onset threshold, together with enhanced excitation displacement on the nozzle end face, facilitated by the megahertz multiple Fourier horns in resonance, led to high-rate ejection of micrometer- sized monodisperse droplets (>10(7) droplets/s) at low electrical drive power (<;1 W) with short initiation time (<;0.05 s). This is in stark contrast to the Rayleigh-Plateau instability of a liquid jet, which ejects one droplet at a time. The measured diameters of the droplets ranging from 2.2 to 4.6 μm at 2 to 1 MHz drive frequency fall within the optimum particle size range for pulmonary drug delivery.

  14. Midplane Faraday Rotation: A densitometer for BPX

    International Nuclear Information System (INIS)

    Jobes, F.C.; Mansfield, D.K.

    1992-02-01

    The density in a high field, high density tokamak such as BPX can be determined by measuring the Faraday rotation of a 10.6 μm laser directed tangent to the toroidal field. If there is a horizontal array of such beams, then n e (R) can be readily obtained with a simple Abel version about the center line of the tokamak. For BPX operated at full field and density, the rotation angle would be quite large -- about 75 degrees per pass. A layout in which a single laser beam is fanned out in the horizontal midplane of the tokamak, with a set of retroreflectors on the far side of the vacuum vessel, would provide good spatial resolution, depending only upon the number of reflectors. With this proposed layout, only one window would be needed. Because the rotation angle is never more than 1 ''fringe,'' the data is always good, and it is also a continuous measurement in time. Faraday rotation is dependent only upon the plasma itself, and thus is not sensitive to vibration of the optical components. Simulations of the expected results show that BPX would be well served even at low densities by a Midplane Faraday Rotation densitometer of ∼64 channels. Both TFTR and PBX-M would be suitable test beds for the BPX system

  15. Magneto-optical Faraday rotation of semiconductor nanoparticles embedded in dielectric matrices.

    Science.gov (United States)

    Savchuk, Andriy I; Stolyarchuk, Ihor D; Makoviy, Vitaliy V; Savchuk, Oleksandr A

    2014-04-01

    Faraday rotation has been studied for CdS, CdTe, and CdS:Mn semiconductor nanoparticles synthesized by colloidal chemistry methods. Additionally these materials were prepared in a form of semiconductor nanoparticles embedded in polyvinyl alcohol films. Transmission electron microscopy and atomic force microscopy analyses served as confirmation of nanocrystallinity and estimation of the average size of the nanoparticles. Spectral dependence of the Faraday rotation for the studied nanocrystals and nanocomposites is correlated with a blueshift of the absorption edge due to the confinement effect in zero-dimensional structures. Faraday rotation spectra and their temperature behavior in Mn-doped nanocrystals demonstrates peculiarities, which are associated with s, p-d exchange interaction between Mn²⁺ ions and band carriers in diluted magnetic semiconductor nanostructures.

  16. Fast Tracker (FTK): A Hardware Track Finder for the ATLAS Trigger

    CERN Document Server

    Mitani, Takashi; The ATLAS collaboration

    2015-01-01

    During the 2010-2012 run of Large Hadron Collider experiment, the ATLAS trigger system was successfully operated and it contributed to several important results such as observation of Higgs boson with a mass of about 125 GeV. From 2015, collision energy will increase to 13-14 TeV and its instantaneous luminosity will reach $1$-$2\\times10^{34}$cm$^{-2}$s$^{-1}$ with a 25 ns bunch crossing period. Due to the energy increase, the cross sections for SM processes are expected to get much larger. Additionally, the number of overlapping proton-proton interactions per bunch crossing, which is refereed to as pile-up, is expected to increase significantly up to about 80. Therefore it will be challenging to control trigger rates while keeping good efficiency for interesting physics events. This document summarizes the development of Fast Tracker and its tracking performance for the ATLAS experiment. The Fast Tracker is a custom electronics system that will operate at the full Level 1 accepted rate of 100 kHz and provide...

  17. The Faraday effect revisited: General theory

    DEFF Research Database (Denmark)

    Cornean, Horia Decebal; Nenciu, Gheorghe; Pedersen, Thomas Garm

    This paper is the first in a series revisiting the Faraday effect, or more generally, the theory of electronic quantum transport/optical response in bulk media in the presence of a constant magnetic field. The independent electron approximation is assumed. For free electrons, the transverse...

  18. Ultra-Fast Tracking Power Supply with 4th order Output Filter and Fixed-Frequency Hysteretic Control

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    A practical solution is presented for the design of a non-isolated DC/DC power converter with very low output ripple voltage and very fast output voltage step response. The converter is intended for use as an envelope tracking power supply for an RFPA (Radio Frequency Power Amplifier) in a Tetra2...

  19. Faraday effect in Cd1-xMnxTe semimagnetic semiconductor

    International Nuclear Information System (INIS)

    Vatamanyuk, P.P.; Savitskij, A.V.; Savchuk, A.I.; Ul'yanitskij, K.S.

    1988-01-01

    The Faraday effect is investigated in the semimagnetic semiconductor Cd 1-x Mn x Te (0≥x≤0.3) in the spectral range from 0.6 to 1.8 eV at temperatures between 4.2 and 350 K and in magnetic fields up to 250 kOe. Some peculiarities in the dispersion of the Faraday rotation (FR) are observed which are connected with a change in the direction of rotation depending on the composition and temperature. The results are analyzed by assuming the FR to consist of three components: an interband, exciton and intracentral contribution. The deviation of FR from saturation in strong magnetic fields is interpreted within the framework of antiferromagnetic exchange interaction between the Mn 2+ ions. On the basis of an analysis of the FR temperature dependence it is suggested that the spontaneous Faraday effect is characteristic of semimagnetic semiconductors in spin glass phase

  20. Faraday rotation near charged black holes and other electrovacuum geometries

    International Nuclear Information System (INIS)

    Gerlach, U.H.

    1975-01-01

    In space permeated by a steady background electromagnetic field a gravitational wave and an electromagnetic wave not only undergo beat frequency oscillations, but the linear polarizations of these waves undergo Faraday rotations as well. The beating and the Faraday rotations are inextricably related. The classification of these phenomena requires three parameters, the three Euler parameters of SU(2). They specify in a more general sense the ''polarization'' of an electrograviton mode. The evolution of the beat frequency oscillations and the Faraday rotations along a propagating wave front is described as a moving point in SU(2). Consequently, a charged black hole serves not only as a catalyst for converting suitably directed electromagnetic radiation into gravitational radiation, but also as an agent that randomized the linear polarizations of radiation emerging from it. An assessment of these phenomena in relation to the origin of Weber's signals is given

  1. The Faraday effect revisited: General theory

    DEFF Research Database (Denmark)

    Cornean, Horia Decebal; Nenciu, Gheorghe; Pedersen, Thomas Garm

    2006-01-01

    This paper is the first in a series revisiting the Faraday effect, or more generally, the theory of electronic quantum transport/optical response in bulk media in the presence of a constant magnetic field. The independent electron approximation is assumed. At zero temperature and zero frequency...

  2. Nonlinear Faraday rotation in samarium vapor

    International Nuclear Information System (INIS)

    Barkov, L.M.; Melik-Pashaev, D.A.; Zolotorev, M.S.

    1988-01-01

    Experiments on nonlinear magnetic optical (Faraday) rotation on resonance transitions of atomic samarium are described. Measurements were carried out on transitions with different angular momenta of upper and lower states: 1→0, 0→1 and 1→1. Qualitative explanations of observed phenomena are given

  3. Effects of Faraday Rotation Observed in Filter Magnetograph Data

    Science.gov (United States)

    Hagyard, Mona J.; Adams, Mitzi L.; Smith, J. E.; West, Edward A.

    1999-01-01

    In this paper we analyze the effects of Faraday rotation on the azimuth of the transverse magnetic field from observations taken with the Marshall Space Flight Center's vector magnetograph for a simple sunspot observed on June 9, 1985. Vector magnetograms were obtained over the wavelength interval of 170 mA redward of line center of the Fe I 5250.22 A spectral line to 170 mA to the blue, in steps of 10 mA. These data were analyzed to produce the variation of the azimuth as a function of wavelength at each pixel over the field of vi ew of the sunspot. At selected locations in the sunspot, curves of the observed variation of azimuth with wavelength were compared with model calculations for the amount of Faraday rotation of the azimuth. From these comparisons we derived the amount of rotation as functions of bo th the magnitude and inclination of the sunspot's field and deduced the ranges of these field values for which Faraday rotation presents a significant problem in observations taken near the center of a spectral line.

  4. Development and first experimental tests of Faraday cup array.

    Science.gov (United States)

    Prokůpek, J; Kaufman, J; Margarone, D; Krůs, M; Velyhan, A; Krása, J; Burris-Mog, T; Busold, S; Deppert, O; Cowan, T E; Korn, G

    2014-01-01

    A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry. This is a unique method for two-dimensional visualisation of ion currents from laser-generated plasmas. A technical description of the new type of Faraday cup is introduced along with an ad hoc data analysis procedure. Experimental results obtained during campaigns at the Petawatt High-Energy Laser for Heavy Ion Experiments (GSI, Darmstadt) and at the Prague Asterix Laser System (AS CR) are presented. Advantages and limitations of the used diagnostic system are discussed.

  5. Construction of the Faraday Cup based on fluorescent screen as an electron beam sensor

    International Nuclear Information System (INIS)

    Sutadi; Rany Saptaaji; Suhartono; Sukaryono

    2016-01-01

    The Faraday Cup based on fluorescent screen as an electron beam profile sensor at electron accelerator has been conducted. In the principle, the electron beam which obtained from the electron source and accelerated in the accelerator tube will obtain the light which can be observed visually when it interact with fluorescent material (phosphorescent). This Faraday Cup for electron beam sensor was made from the modified TV tube. The main component of this Faraday Cup construction includes: 17 inch TV tube, SS reducer flange and the vacuum adhesive. There are two kind of test has been conducted, that is the vacuum level test and the electron beam sensor test. The vacuum level test was conducted by measuring the final vacuum level that can be reach, while the electron beam sensor test was conducted by monitoring of the electron beam profile that was trapped by Faraday Cup visually. The test result shows that TV tube can be modified as the Faraday Cup to sensor electron beam in the electron accelerator. (author)

  6. Preinjector for Linac 1, Faraday cage

    CERN Multimedia

    1974-01-01

    The 50 MeV Linac 1 started up in 1958 as injector to the 26 GeV PS, with a 520 kV Cockcroft-Walton generator as its preinjector, housed in a vast Faraday cage, visible here. When the Cockcroft-Walton broke down in 1973, it was replaced by a much smaller SAMES generator, of the kind used for electrostatic separators. From 1980 on, Linac 2 took over as injector for the 800 MeV Booster, and Linac 1 continued as injector for LEAR. In 1984, the electrostatic preinjector (i.e. the Faraday cage with its contents, SAMES generator and all) was replaced by a 520 keV RFQ. At the lower left corner we see the HV connectors to the SAMES generator, at the right edge part of the opened electronics-platform. Jean-Luc Vallet sees to it that all parts are properly grounded. See also 7403073X, 7403074X, 7403081X, 7403083X.

  7. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte; Jacobsen, Steffen

    2008-01-01

    BACKGROUND AND PURPOSE: Very few studies have focused on patient characteristics that influence length of stay (LOS) in fast-track total hip (THR) and knee arthroplasty (TKR). The aim of this prospective study was to identify patient characteristics associated with LOS and patient satisfaction...... aids, pre- and postoperative hemoglobin levels, the need for blood transfusion, ASA score, and time between surgery and mobilization, were all found to influence postoperative outcome in general, and LOS and patient satisfaction in particular. INTERPRETATION: We identified several patient...... characteristics that influence postoperative outcome, LOS, and patient satisfaction in our series of consecutive fast-track joint replacement patients, enabling further attention to be paid to certain aspects of surgery and rehabilitation....

  8. Transparent Flexible Active Faraday Cage Enables In Vivo Capacitance Measurement in Assembled Microsensor.

    Science.gov (United States)

    Ahmadi, Mahdi; Rajamani, Rajesh; Sezen, Serdar

    2017-10-01

    Capacitive micro-sensors such as accelerometers, gyroscopes and pressure sensors are increasingly used in the modern electronic world. However, the in vivo use of capacitive sensing for measurement of pressure or other variables inside a human body suffers from significant errors due to stray capacitance. This paper proposes a solution consisting of a transparent thin flexible Faraday cage that surrounds the sensor. By supplying the active sensing voltage simultaneously to the deformable electrode of the capacitive sensor and to the Faraday cage, the stray capacitance during in vivo measurements can be largely eliminated. Due to the transparency of the Faraday cage, the top and bottom portions of a capacitive sensor can be accurately aligned and assembled together. Experimental results presented in the paper show that stray capacitance is reduced by a factor of 10 by the Faraday cage, when the sensor is subjected to a full immersion in water.

  9. Mobile Phone Faraday Cage

    OpenAIRE

    French, M M J

    2011-01-01

    A Faraday cage is an interesting physics phenomena where an electromagnetic wave can be excluded from a volume of space by enclosure with an electrically conducting material. The practical application of this in the classroom is to block the signal to a mobile phone by enclosing it in a metal can! The background of the physics behind this is described in some detail followed by a explanation of some demonstrations and experiments which I have used.

  10. Readmission rates after a planned hospital stay of 2 versus 3 days in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Andersen, Jens; Hjort-Jakobsen, Dorthe; Christiansen, P. S.

    2007-01-01

    BACKGROUND: Initial programmes of fast-track open colonic surgery with a planned 2-day postoperative hospital stay have had a high readmission rate (about 20 per cent). The aim of this large, consecutive series was to compare readmission rates after a fast-track open colonic surgery programme...... from August 2004. All patients were examined 8 and 30 days after surgery. RESULTS: Readmission rates fell from 20.1 per cent in 408 patients with a planned 2-day hospital stay (period 1) to 11.3 per cent in 133 patients with a planned 3-day hospital stay (period 2) (P ... hospital stay was 2 and 3 days, median stay after readmission was 5 and 5.5 days, and median (mean) total stay was 3 (5.6) and 3 (5.7) days in periods 1 and 2 respectively. The readmission rate in period 2 was lower because there were fewer readmissions for short-term observation or social reasons...

  11. Fast-track aquifer characterization and bioremediation of groundwater

    International Nuclear Information System (INIS)

    Owen, S.B.; Erskine, J.A.; Adkisson, C.

    1995-01-01

    A short duration step-drawdown pumping test has been used to characterize a highly permeable aquifer contaminated with petroleum hydrocarbons in support of an in situ, closed loop extraction and reinjection bioremediation system for groundwater. The short-term pumping test produces a manageable quantity of contaminated groundwater while yielding a range of values for transmissivity and specific yield parameters. This range of aquifer coefficients is used in an analytical model to estimate a range of groundwater extraction rates that provide a suitable radius of influence for the extraction and reinjection system. A multi-enzyme complex catalyzed bioremediation process has been used to aerobically degrade petroleum hydrocarbons. Enzymes, amino acids, and biosurfactants are supplied to the extracted groundwater to significantly speed up the degradation by naturally occurring bacteria. During the process, amino acids promote the rapid growth of the microbial population while enzymes and bacteria attach to hydrocarbons forming a transformation state complex that degrades to fatty acids, carbon dioxide, and water. This paper presents a case study of a fast-track bioremediation using pumping test data, analytical modeling, and an enzyme technology

  12. Enhancement of Faraday rotation at photonic-band-gap edge in garnet-based magnetophotonic crystals

    International Nuclear Information System (INIS)

    Zhdanov, A.G.; Fedyanin, A.A.; Aktsipetrov, O.A.; Kobayashi, D.; Uchida, H.; Inoue, M.

    2006-01-01

    Spectral dependences of Faraday rotation angle in one-dimensional garnet-based magnetophotonic crystals are considered. The enhancement of Faraday angle is demonstrated at the photonic band gap (PBG) edge both theoretically and experimentally. It is shown to be associated with the optical field localization in the magnetic layers of the structure. The advantages of magnetophotonic crystals in comparison with traditional magnetic microcavities are discussed. The specially designed microcavity structures optimized for the Faraday effect enhancement at the PBG edge are suggested

  13. Orthotropic conductivity reconstruction with virtual-resistive network and Faraday's law

    KAUST Repository

    Lee, Min-Gi

    2015-06-01

    We obtain the existence and the uniqueness at the same time in the reconstruction of orthotropic conductivity in two-space dimensions by using two sets of internal current densities and boundary conductivity. The curl-free equation of Faraday\\'s law is taken instead of the elliptic equation in a divergence form that is typically used in electrical impedance tomography. A reconstruction method based on layered bricks-type virtual-resistive network is developed to reconstruct orthotropic conductivity with up to 40% multiplicative noise.

  14. ionFR: Ionospheric Faraday rotation [Dataset

    NARCIS (Netherlands)

    Sotomayor-Beltran, C.; et al., [Unknown; Hessels, J.W.T.; van Leeuwen, J.; Markoff, S.; Wijers, R.A.M.J.

    2013-01-01

    IonFR calculates the amount of ionospheric Faraday rotation for a specific epoch, geographic location, and line-of-sight. The code uses a number of publicly available, GPS-derived total electron content maps and the most recent release of the International Geomagnetic Reference Field. ionFR can be

  15. Faraday rotation in multiple quantum wells of GaAs/AlGaAs

    International Nuclear Information System (INIS)

    Dudziak, E.; Bozym, J.; Prochnik, D.; Wasilewski, Z.R.

    1996-01-01

    We report on the results of first measurements on the Faraday rotation of modulated n-doped multiple quantum wells of GaAs/Al x Ga 1-x As (x = 0.312). The measurements have been performed in the magnetic fields up to 13 T at the temperature of 2 K, in the spectral region of interband transitions. A rich structure of magneto-excitons has been found in the measured spectra. Faraday rotation (phase) measurements are proposed as an alternative method to the photoluminescence excitation for investigations of magneto-excitons in quantum wells. The dependence of measured Faraday rotation on magnetic field and hypothetical connections with quantum Hall effect are also discussed. (author)

  16. Enhanced Faraday rotation in one dimensional magneto-plasmonic structure due to Fano resonance

    Science.gov (United States)

    Sadeghi, S.; Hamidi, S. M.

    2018-04-01

    Enhanced Faraday rotation in a new type of magneto-plasmonic structure with the capability of Fano resonance, has been reported theoretically. A magneto-plasmonic structure composed of a gold corrugated layer deposited on a magneto-optically active layer was studied by means of Lumerical software based on finite-difference time-domain. In our proposed structure, plasmonic Fano resonance and localized surface plasmon have induced enhancement in magneto-optical Faraday rotation. It is shown that the influence of geometrical parameters in gold layer offers a desirable platform for engineering spectral position of Fano resonance and enhancement of Faraday rotation.

  17. Faraday rotation influence factors in tellurite-based glass and fibers

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Qiuling; Wang, Qingwei [Henan University of Technology, School of Materials Science and Engineering, Zhengzhou, Henan (China); Wang, Hui; Chen, Qiuping [Politecnico di Torino, Department of Applied Science and Technology, Turin (Italy)

    2015-09-15

    The Faraday rotation influence factors in tellurite-based glass and fibers were studied by experiments and simulations. TeO{sub 2}-ZnO-Na{sub 2}O-BaO glass family was fabricated and characterized in terms of the thermal and magneto-optical properties. Two core-cladding pairs for two fibers were selected from fabricated glasses. The Verdet constants of the glasses and fibers were measured at different wavelengths using a homemade optical bench, and the Verdet constant of fiber was close to that of the bulk glass. The influence from external factors (wavelength, laser power and magnetic field) and internal factors (thermal expansion coefficient difference, refractive index and Verdet constant of core and cladding) on Faraday rotation in fibers was investigated and discussed, and the purpose of this study is to improve the Faraday rotation in tellurite fibers for MO device applications both from internal material property match and external parameter configuration in measurement. (orig.)

  18. Faraday rotation influence factors in tellurite-based glass and fibers

    International Nuclear Information System (INIS)

    Chen, Qiuling; Wang, Qingwei; Wang, Hui; Chen, Qiuping

    2015-01-01

    The Faraday rotation influence factors in tellurite-based glass and fibers were studied by experiments and simulations. TeO 2 -ZnO-Na 2 O-BaO glass family was fabricated and characterized in terms of the thermal and magneto-optical properties. Two core-cladding pairs for two fibers were selected from fabricated glasses. The Verdet constants of the glasses and fibers were measured at different wavelengths using a homemade optical bench, and the Verdet constant of fiber was close to that of the bulk glass. The influence from external factors (wavelength, laser power and magnetic field) and internal factors (thermal expansion coefficient difference, refractive index and Verdet constant of core and cladding) on Faraday rotation in fibers was investigated and discussed, and the purpose of this study is to improve the Faraday rotation in tellurite fibers for MO device applications both from internal material property match and external parameter configuration in measurement. (orig.)

  19. Assessment of fast and thermal neutron ambient dose equivalents around the KFUPM neutron source storage area using nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco, P. O. Box 13027, Dhahran 31311 (Saudi Arabia); Qureshi, M.A. [Center for Applied Physical Sciences, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-11-15

    A set of five {sup 241}Am-Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16Ci each and the other two are of 5Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters on their surfaces for thermal neutron detection via B10(n,{alpha})Li6 and Li6(n,{alpha})H3 nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks cm{sup -2}{mu}Sv{sup -1} and 31.5 alpha tracks cm{sup -2}{mu}Sv{sup -1}, respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as 182nSvh{sup -1} up to 10.4{mu}Svh{sup -1} whereas those for thermal neutron ranged from as low as 7nSvh{sup -1} up to 9.3{mu}Svh{sup -1}. The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and 182nSvh{sup -1} from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron

  20. Faraday rotation measurements in maghemite-silica aerogels

    International Nuclear Information System (INIS)

    Taboada, E.; Real, R.P. del; Gich, M.; Roig, A.; Molins, E.

    2006-01-01

    Faraday rotation measurements have been performed on γ-Fe 2 O 3 /SiO 2 nanocomposite aerogels which are light, porous and transparent magnetic materials. The materials have been prepared by sol-gel polymerization of a silicon alkoxide, impregnation of the intermediate silica gel with a ferrous salt and supercritical drying of the gels. During supercritical evacuation of the solvent, spherical nanoparticles of iron oxide, with a mean particle diameter of 8.1±2.0 nm, are formed and are found to be homogenously distributed within the silica matrix. The specific Faraday rotation of the composite was measured at 0.6 T using polarized light of 810 nm, being 29.6 deg./cm. The changes in the plane of polarization of the transmitted light and the magnetization of the material present similar magnetic field dependencies and are characteristic of a superparamagnetic system

  1. Temperature Dependence of Faraday Effect-Induced Bias Error in a Fiber Optic Gyroscope.

    Science.gov (United States)

    Li, Xuyou; Liu, Pan; Guang, Xingxing; Xu, Zhenlong; Guan, Lianwu; Li, Guangchun

    2017-09-07

    Improving the performance of interferometric fiber optic gyroscope (IFOG) in harsh environments, such as magnetic field and temperature field variation, is necessary for its practical applications. This paper presents an investigation of Faraday effect-induced bias error of IFOG under varying temperature. Jones matrix method is utilized to formulize the temperature dependence of Faraday effect-induced bias error. Theoretical results show that the Faraday effect-induced bias error changes with the temperature in the non-skeleton polarization maintaining (PM) fiber coil. This phenomenon is caused by the temperature dependence of linear birefringence and Verdet constant of PM fiber. Particularly, Faraday effect-induced bias errors of two polarizations always have opposite signs that can be compensated optically regardless of the changes of the temperature. Two experiments with a 1000 m non-skeleton PM fiber coil are performed, and the experimental results support these theoretical predictions. This study is promising for improving the bias stability of IFOG.

  2. Theory of Kerr and Faraday rotations and linear dichroism in Topological Weyl Semimetals.

    Science.gov (United States)

    Kargarian, Mehdi; Randeria, Mohit; Trivedi, Nandini

    2015-08-03

    We consider the electromagnetic response of a topological Weyl semimetal (TWS) with a pair of Weyl nodes in the bulk and corresponding Fermi arcs in the surface Brillouin zone. We compute the frequency-dependent complex conductivities σαβ(ω) and also take into account the modification of Maxwell equations by the topological θ-term to obtain the Kerr and Faraday rotations in a variety of geometries. For TWS films thinner than the wavelength, the Kerr and Faraday rotations, determined by the separation between Weyl nodes, are significantly larger than in topological insulators. In thicker films, the Kerr and Faraday angles can be enhanced by choice of film thickness and substrate refractive index. We show that, for radiation incident on a surface with Fermi arcs, there is no Kerr or Faraday rotation but the electric field develops a longitudinal component inside the TWS, and there is linear dichroism signal. Our results have implications for probing the TWS phase in various experimental systems.

  3. Faraday rotation and magneto-optical figure of merit for the magnetite magnetic fluids

    Directory of Open Access Journals (Sweden)

    Kalandadze L.

    2011-05-01

    Full Text Available In the present paper, using magnetite magnetic fluids as examples, we consider the optical and magneto-optical properties of magnetic fluids based on particles of magnetic oxides, for the optical constants of the material of which, n and k , the relation k2 ≺≺ n2 holds. In this work the Faraday rotation is represented within the theoretical Maxwell-Garnett model. A theoretical analysis has shown that Faraday rotation for magnetic fluids is related to the Faraday rotation on the material of particles by the simple relation. According to this result  in specific experimental conditions the values of the Faraday rotation prorate to q , which is the occupancy of the volume of the magnetic fluid with magnetic particles and spectral dependences of effect in magnetic fluid and in the proper bulk magnetic are similar. We also show that the values of the magneto-optical figure of merit for ultrafine medium and for the bulk material are equal.

  4. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.; Seidman, D.N.

    1977-01-01

    A novel Faraday cup is described which allows the simultaneous observation and measurement of ion-beam currents. The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA), which serves as the basis of an internal image intensification system (a gain of >10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion current which is measured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30-keV Ar + ion beam is presented as an illustrative example. We have also employed this Faraday cup to observe and measure 30-keV Cr + , Mo + , or W + , and 18-keV Au + ion beams employed for the in situ irradiation of field-ion microscope specimens

  5. Faraday anomalous dispersion optical filters

    Science.gov (United States)

    Shay, T. M.; Yin, B.; Alvarez, L. S.

    1993-01-01

    The effect of Faraday anomalous dispersion optical filters on infrared and blue transitions of some alkali atoms is calculated. A composite system is designed to further increase the background noise rejection. The measured results of the solar background rejection and image quality through the filter are presented. The results show that the filter may provide high transmission and high background noise rejection with excellent image quality.

  6. Double cascade turbulence and Richardson dispersion in a horizontal fluid flow induced by Faraday waves.

    Science.gov (United States)

    von Kameke, A; Huhn, F; Fernández-García, G; Muñuzuri, A P; Pérez-Muñuzuri, V

    2011-08-12

    We report the experimental observation of Richardson dispersion and a double cascade in a thin horizontal fluid flow induced by Faraday waves. The energy spectra and the mean spectral energy flux obtained from particle image velocimetry data suggest an inverse energy cascade with Kolmogorov type scaling E(k) ∝ k(γ), γ ≈ -5/3 and an E(k) ∝ k(γ), γ ≈ -3 enstrophy cascade. Particle transport is studied analyzing absolute and relative dispersion as well as the finite size Lyapunov exponent (FSLE) via the direct tracking of real particles and numerical advection of virtual particles. Richardson dispersion with ∝ t(3) is observed and is also reflected in the slopes of the FSLE (Λ ∝ ΔR(-2/3)) for virtual and real particles.

  7. A fast track path improves access to palliative care for people with learning disabilities.

    Science.gov (United States)

    Whitington, Jane; Ma, Peng

    People with learning disabilities often experience inequalities in accessing general health services. This group, their families and carers need access to effective palliative care when facing a life limiting illness. This article describes the development and implementation of a fast track referral pathway for people with learning disabilities at St Francis Hospice in Essex. Our aim is to share this pathway so others can replicate the collaborative working to improve access to palliative care services for this group.

  8. Fall-related admissions after fast-track total hip and knee arthroplasty - cause of concern or consequence of success?

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kehlet, Henrik; Hip, Lundbeck Foundation Centre for Fast-track

    2013-01-01

    Total hip (THA) and knee arthroplasty (TKA) are common procedures in elderly persons, who are at potential increased risk of postoperative fall due to loss of muscle strength and impaired balance. Fast-track surgery with early mobilization and opioid-sparing analgesia have improved outcomes after...

  9. Faraday tarotion: new parameter for electromagnetic pulse propagation in magnetoplasma

    International Nuclear Information System (INIS)

    Bloch, S.C.; Lyons, P.W.

    1976-01-01

    Extreme distortion and time-dependent Faraday rotation occur for propagation of short electromagnetic pulses in magnetoplasma, for some ranges of plasma parameters. In order to relate pulse and monochromatic waves for propagation-path diagnostic purposes, a new parameter is introduced for the transmitted pulse train which has properties that correspond very accurately to results that would be expected for Faraday rotation of a continuous wave having the central frequency of the incident pulse spectrum. Results for 5-ns pulses (10 GHz) are presented for varying propagating length, static magnetic field, electron density, and collisional absorption

  10. Compensation of thermally induced polarisation distortions in Faraday isolators

    International Nuclear Information System (INIS)

    Khazanov, E A

    1999-01-01

    Two new Faraday isolator designs are proposed. They make it possible to compensate partly for the depolarisation of radiation which occurs in magneto-optical elements because of the photoelastic effect caused by heating associated with the absorption of laser radiation. Analytic and numerical comparisons of the new and traditional designs demonstrate a significant (by orders of magnitude) increase in the isolation ratio of the new isolators. The results obtained indicate that it should be possible to construct a Faraday isolator with the isolation ratio of 30 dB for laser radiation with an average power of several kilowatts. (laser applications and other topics in quantum electronics)

  11. Stray-field-induced Faraday contributions in wide-field Kerr microscopy and -magnetometry

    International Nuclear Information System (INIS)

    Markó, D.; Soldatov, I.; Tekielak, M.; Schäfer, R.

    2015-01-01

    The magnetic domain contrast in wide-field Kerr microscopy on bulk specimens can be substantially distorted by non-linear, field-dependent Faraday rotations in the objective lens that are caused by stray-field components emerging from the specimen. These Faraday contributions, which were detected by Kerr-magnetometry on grain-oriented iron–silicon steel samples, are thoroughly elaborated and characterized. They express themselves as a field-dependent gray-scale offset to the domain contrast and in highly distorted surface magnetization curves if optically measured in a wide field Kerr microscope. An experimental method to avoid such distortions is suggested. In the course of these studies, a low-permeability part in the surface magnetization loop of slightly misoriented (110)-surfaces in iron–silicon sheets was discovered that is attributed to demagnetization effects in direction perpendicular to the sheet surface. - Highlights: • Magnetizing a finite sample in a Kerr microscope leads to sample-generated stray-fields. • They cause non-linear, field- and position-dependent Faraday rotations in the objective. • This leads to a modulation of the Kerr contrast and to distorted MOKE loops. • A method to compensate these Faraday rotations is presented

  12. Faraday Rotation and L Band Oceanographic Measurements

    DEFF Research Database (Denmark)

    Skou, Niels

    2003-01-01

    Spaceborne radiometric measurements of the L band brightness temperature over the oceans make it possible to estimate sea surface salinity. However, Faraday rotation in the ionosphere disturbs the signals and must be corrected. Two different ways of assessing the disturbance directly from...

  13. Quantum noise for Faraday light–matter interfaces

    DEFF Research Database (Denmark)

    Vasliyev, D.V.; Hammerer, K.; Korolev, N.

    2012-01-01

    In light–matter interfaces based on the Faraday effect, quite a number of quantum information protocols have been successfully demonstrated. In order to further increase the performance and fidelities achieved in these protocols, a deeper understanding of the relevant noise and decoherence...

  14. Absorption lines, Faraday rotation, and magnetic field estimates for QSO absorption-line clouds

    International Nuclear Information System (INIS)

    Kronberg, P.P.; Perry, J.J.

    1982-01-01

    We have estimated the extragalactic component of Faraday rotation for a sample of 37 QSOs for which there is good absorption line data, which we have also analyzed. Statistical evidence is presented which suggests that we have isolated a component of Faraday rotation which is occurring in the absorption clouds of some QSOs

  15. Parsec-scale Faraday rotation and polarization of 20 active galactic nuclei jets

    Science.gov (United States)

    Kravchenko, E. V.; Kovalev, Y. Y.; Sokolovsky, K. V.

    2017-05-01

    We perform polarimetry analysis of 20 active galactic nuclei jets using the very long baseline array at 1.4, 1.6, 2.2, 2.4, 4.6, 5.0, 8.1, 8.4 and 15.4 GHz. The study allowed us to investigate linearly polarized properties of the jets at parsec scales: distribution of the Faraday rotation measure (RM) and fractional polarization along the jets, Faraday effects and structure of Faraday-corrected polarization images. Wavelength dependence of the fractional polarization and polarization angle is consistent with external Faraday rotation, while some sources show internal rotation. The RM changes along the jets, systematically increasing its value towards synchrotron self-absorbed cores at shorter wavelengths. The highest core RM reaches 16 900 rad m-2 in the source rest frame for the quasar 0952+179, suggesting the presence of highly magnetized, dense media in these regions. The typical RM of transparent jet regions has values of an order of a hundred rad m-2. Significant transverse RM gradients are observed in seven sources. The magnetic field in the Faraday screen has no preferred orientation, and is observed to be random or regular from source to source. Half of the sources show evidence for the helical magnetic fields in their rotating magneto-ionic media. At the same time jets themselves contain large-scale, ordered magnetic fields and tend to align its direction with the jet flow. The observed variety of polarized signatures can be explained by a model of spine-sheath jet structure.

  16. Incomplete Faraday cage effect of helicopters used in platform live-line maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, G.W.; Bodger, P.S.; Woudberg, J.J. [University of Canterbury, Christchurch (New Zealand). Dept. of Electrical and Electronic Engineering

    1998-03-01

    The use of helicopters for maintenance on live overhead transmission lines has become a realistic option. The helicopter blades, body and working platform can be seen as creating an incomplete Faraday cage which may be an enhancement to live-line worker safety. This paper simulates the condition using a Faraday cage which can be dismantled in a controlled laboratory environment, to ascertain the effectiveness of apparatus. (author)

  17. Competition of Faraday rotation and birefringence in femtosecond laser direct written waveguides in magneto-optical glass.

    Science.gov (United States)

    Liu, Qiang; Gross, S; Dekker, P; Withford, M J; Steel, M J

    2014-11-17

    We consider the process of Faraday rotation in femtosecond laser direct-write waveguides. The birefringence commonly associated with such waveguides may be expected to impact the observable Faraday rotation. Here, we theoretically calculate and experimentally verify the competition between Faraday rotation and birefringence in two waveguides created by laser writing in a commercial magneto-optic glass. The magnetic field applied to induce Faraday rotation is nonuniform, and as a result, we find that the two effects can be clearly separated and used to accurately determine even weak birefringence. The birefringence in the waveguides was determined to be on the scale of Δn = 10(-6) to 10(-5). The reduction in Faraday rotation caused by birefringence of order Δn = 10(-6) was moderate and we obtained approximately 9° rotation in an 11 mm waveguide. In contrast, for birefringence of order 10(-5), a significant reduction in the polarization azimuth change was found and only 6° rotation was observed.

  18. Fast track land reform, tenure security and investments in soil conservation: Micro-evidence from Mazowe district in Zimbabwe

    NARCIS (Netherlands)

    Zikhali, P.

    2010-01-01

    The government of Zimbabwe launched the Fast Track Land Reform Programme (FTLRP) in 2000 as part of its ongoing land reform and resettlement programme which aims to address a racially skewed land distribution. Its goal has been to accelerate both land acquisition and redistribution, targeting at

  19. Non-reciprocity of Faraday rotation in gyrotropic crystals

    OpenAIRE

    Vlokh R.; Adamenko D.

    2008-01-01

    It is shown that, under the conditions of coexisting natural optical activity and non-zero linear optical birefringence, reversal of the light wave vector sign can result in changing angle of Faraday rotation.

  20. Giant Faraday Rotation of High-Order Plasmonic Modes in Graphene-Covered Nanowires.

    Science.gov (United States)

    Kuzmin, Dmitry A; Bychkov, Igor V; Shavrov, Vladimir G; Temnov, Vasily V

    2016-07-13

    Plasmonic Faraday rotation in nanowires manifests itself in the rotation of the spatial intensity distribution of high-order surface plasmon polariton (SPP) modes around the nanowire axis. Here we predict theoretically the giant Faraday rotation for SPPs propagating on graphene-coated magneto-optically active nanowires. Upon the reversal of the external magnetic field pointing along the nanowire axis some high-order plasmonic modes may be rotated by up to ∼100° on the length scale of about 500 nm at mid-infrared frequencies. Tuning the carrier concentration in graphene by chemical doping or gate voltage allows for controlling SPP-properties and notably the rotation angle of high-order azimuthal modes. Our results open the door to novel plasmonic applications ranging from nanowire-based Faraday isolators to the magnetic control in quantum-optical applications.

  1. A variable suppressed aperture and Faraday cup system

    International Nuclear Information System (INIS)

    Price, H.G.; Charlesworth, T.R.

    1979-02-01

    The injection system of the NSF accelerator within the high voltage enclosure is illustrated. The optics calls for a waist close to the entrance of the 500 kV accelerator tube. This waist will be the initial diagnostic point on the injection path for determining ion source performance and transmission through the later system. This will be made by determining the beam current after a preliminary mass analysis by the 30 0 magnet. To provide this diagnostic and to enable a waist to be formed at this point, a variable aperture and Faraday cup system is required. The Faraday cup will measure the beam transmitted by the aperture. Maximisation of this beam by adjustment of the preceding optical elements will ensure the waist in the beam at that point. (author)

  2. Fast particle tracking with wake fields

    Energy Technology Data Exchange (ETDEWEB)

    Dohlus, M.; Floettmann, K.; Henning, C.

    2012-01-15

    Tracking calculations of charged particles in electromagnetic fields require in principle the simultaneous solution of the equation of motion and of Maxwell's equations. In many tracking codes a simpler and more efficient approach is used: external fields like that of the accelerating structures are provided as field maps, generated in separate computations and for the calculation of self fields the model of a particle bunch in uniform motion is used. We describe how an externally computed wake function can be approximated by a table of Taylor coefficients and how the wake field kick can be calculated for the particle distribution in a tracking calculation. The integrated kick, representing the effect of a distributed structure, is applied at a discrete time. As an example, we use our approach to calculate the emittance growth of a bunch in an undulator beam pipe due to resistive wall wake field effects. (orig.)

  3. Multiple feature fusion via covariance matrix for visual tracking

    Science.gov (United States)

    Jin, Zefenfen; Hou, Zhiqiang; Yu, Wangsheng; Wang, Xin; Sun, Hui

    2018-04-01

    Aiming at the problem of complicated dynamic scenes in visual target tracking, a multi-feature fusion tracking algorithm based on covariance matrix is proposed to improve the robustness of the tracking algorithm. In the frame-work of quantum genetic algorithm, this paper uses the region covariance descriptor to fuse the color, edge and texture features. It also uses a fast covariance intersection algorithm to update the model. The low dimension of region covariance descriptor, the fast convergence speed and strong global optimization ability of quantum genetic algorithm, and the fast computation of fast covariance intersection algorithm are used to improve the computational efficiency of fusion, matching, and updating process, so that the algorithm achieves a fast and effective multi-feature fusion tracking. The experiments prove that the proposed algorithm can not only achieve fast and robust tracking but also effectively handle interference of occlusion, rotation, deformation, motion blur and so on.

  4. Plasma polarimetry for large Cotton--Mouton and Faraday effects

    International Nuclear Information System (INIS)

    Segre, S.E.

    1995-01-01

    A formalism is presented for treating plasma polarimetry when both the Cotton--Mouton and the Faraday effects are large. For this general case it is shown that, for each measuring chord, up to nine parameters related to the plasma can be determined, instead of the usual single Faraday rotation. These parameters can be measured by a convenient modulation of the polarization state of the input radiation, and they can be used in the reconstruction of the magnetohydrodynamic equilibrium. Thus, the potential of the polarimetric diagnostic can be significantly increased, and the range of plasma conditions where the latter can be used, is extended. The importance of refraction is discussed. copyright 1995 American Institute of Physics

  5. Thin-film magnetless Faraday rotators for compact heterogeneous integrated optical isolators

    Science.gov (United States)

    Karki, Dolendra; Stenger, Vincent; Pollick, Andrea; Levy, Miguel

    2017-06-01

    This report describes the fabrication, characterization, and transfer of ultra-compact thin-film magnetless Faraday rotators to silicon photonic substrates. Thin films of magnetization latching bismuth-substituted rare-earth iron garnets were produced from commercially available materials by mechanical lapping, dice polishing, and crystal-ion-slicing. Eleven- μ m -thick films were shown to retain the 45 ° Faraday rotation of the bulk material to within 2 ° at 1.55 μ m wavelength without re-poling. Anti-reflection coated films evince 0.09 dB insertion loses and better than -20 dB extinction ratios. Lower extinction ratios than the bulk are ascribed to multimode propagation. Significantly larger extinction ratios are predicted for single-mode waveguides. Faraday rotation, extinction ratios, and insertion loss tests on He-ion implanted slab waveguides of the same material yielded similar results. The work culminated with bond alignment and transfer of 7 μ m -thick crystal-ion-sliced 50 × 480 μ m 2 films onto silicon photonic substrates.

  6. Role of preoperative pain, muscle function, and activity level in discharge readiness after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Bandholm, Thomas; Lunn, Troels Haxholdt

    2014-01-01

    therefore investigated the role of preoperative pain and functional characteristics in discharge readiness and actual LOS in fast-track THA and TKA. METHODS: Before surgery, hip pain (THA) or knee pain (TKA), lower-extremity muscle power, functional performance, and physical activity were assessed...

  7. Electrodeless-discharge-vapor-lamp-based Faraday anomalous-dispersion optical filter.

    Science.gov (United States)

    Sun, Qinqing; Zhuang, Wei; Liu, Zhiwen; Chen, Jingbiao

    2011-12-01

    We report an excited-state Faraday anomalous-dispersion optical filter operating on the rubidium 5P(3/2)-5D(5/2) transition (775.9 nm in vacuum) without the use of a pump laser. An electrodeless discharge vapor lamp is employed to replace the Rb vapor cell in a traditional Faraday anomalous-dispersion optical filter system. Atoms can be excited by power rather than a complex frequency-locked pump laser. A proof-of-concept experimental demonstration with a maximum transmission of 1.9% and a filter bandwidth of 650 MHz is presented. © 2011 Optical Society of America

  8. El concepto de estado electro-tónico en Faraday

    OpenAIRE

    Romo Feito, José

    1991-01-01

    Sabemos la centralidad que la noción de estado electro-tónico tuvo en la primera formulación de las ecuaciones de Maxwell. El concepto, sin embargo, proviene de Faraday, que lo introdujo a raíz de su descubrimiento de la inducción electromagnética en 1831, y recurrió a él intermitentemente en los años siguientes. La tesis pretende trazar la evolución del concepto en la obra de Faraday.El capitulo 1 se ocupa, en primer lugar, de proporcionar algunos elementos para comprender la situación de la...

  9. Concluding remarks: Faraday Discussion on chemistry in the urban atmosphere.

    Science.gov (United States)

    Jimenez, Jose L

    2016-07-18

    This article summarises the Concluding remarks from the Faraday Discussion on Chemistry in the Urban Atmosphere. The following themes are addressed: (a) new results that inform our understanding of the evolving sources and composition of the urban atmosphere ("News"); (b) results that identify gaps in our understanding that necessitate further work ("Gaps"); (c) the emerging instrumentation revolution and some of the challenges that it brings; (d) the structural issues of insufficient support for the analysis of field campaigns; and (e) some important areas that were missing from this Faraday Discussion and that should receive an increasing focus in the future.

  10. Fast Track to the Cloud: Design Patterns for 12-Factor Earth Sciences Applications

    Science.gov (United States)

    Pawloski, Andrew; McLaughlin, Brett; Lynnes, Christopher

    2016-01-01

    As expanding service offerings and decreasing prices make the cloud increasingly attractive to Earth Science applications, there are nontrivial practical considerations which can hinder its meaningful use. In this talk, we will discuss architectural recommendations and lessons learned while working on EOSDIS' cloud efforts, particularly the NASA-compliant General Application Platform (NGAP) and its associated applications. Prominent in our findings is the importance of 12-factor design patterns and the powerful "wins" they enable in the cloud. We will share our strategies for "fast-tracking" applications to the cloud --whether they be legacy, planned for the future, or somewhere in between.

  11. Early Progressive Strength Training to Enhance Recovery After Fast-Track Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Kehlet, Henrik; Husted, Henrik

    2014-01-01

    different interventions: 7 weeks of supervised physical rehabilitation with PST (PST group) and without PST (CON group) commenced early after fast-track TKA. The primary outcome was the maximal distance walked in 6 minutes (6-minute walk test). Secondary outcomes were lower extremity strength and power......, knee joint effusion and range of motion, knee pain, and self-reported disability and quality of life. All outcome measures were assessed before TKA (baseline) and 4, 8, and 26 weeks after TKA. RESULTS: There was no statistically significant difference between the PST and CON groups in the change score...

  12. Faraday effect in rare-earth ferrite garnets located in strong magnetic fields

    International Nuclear Information System (INIS)

    Valiev, U.V.; Zvezdin, A.K.; Krinchik, G.S.; Levitin, R.Z.; Mukimov, K.M.; Popov, A.I.

    1983-01-01

    The Faraday effect is investigated experimentally in single crystal specimens of rare earth iron garnets (REIG) R 3 Fe 5 O 12 (R=Y, Gd, Tb, Dy, Er, Tm, Yb, Eu, Sm and Ho) and also in mixed iron garnets Rsub(x)Ysub(3-x)Fesub(5)Osub(12) (R=Tb, Dy). The m.easurements are carried out in pulsed magnetic fields of intensity up to 200 kOe, in a temperature range from 4.2 to 300 K and at a wavelength of the light lambda=1.15 μm. The field dependence of the Faraday effect observed in the REIG cannot be explained if only the usually considered ''paramagnetic'' contribution to the Faraday effect is taken into account. A theory is developed which, besides the paramagnetic mechanism, takes into account a diamagnetic mechanism and also the mixing of the wave functions of the ground and excited multiplets. The contributions of each of these three mechanisms to the angle of rotation of the plane of polarization by the rare earth sublattice of the iron garnet are estimated theoretically. It is concluded that the mixing mechanism contributes significantly to the field and temperature dependences of the Faraday effect in REIG

  13. Signal Tracking Beyond the Time Resolution of an Atomic Sensor by Kalman Filtering

    Science.gov (United States)

    Jiménez-Martínez, Ricardo; Kołodyński, Jan; Troullinou, Charikleia; Lucivero, Vito Giovanni; Kong, Jia; Mitchell, Morgan W.

    2018-01-01

    We study causal waveform estimation (tracking) of time-varying signals in a paradigmatic atomic sensor, an alkali vapor monitored by Faraday rotation probing. We use Kalman filtering, which optimally tracks known linear Gaussian stochastic processes, to estimate stochastic input signals that we generate by optical pumping. Comparing the known input to the estimates, we confirm the accuracy of the atomic statistical model and the reliability of the Kalman filter, allowing recovery of waveform details far briefer than the sensor's intrinsic time resolution. With proper filter choice, we obtain similar benefits when tracking partially known and non-Gaussian signal processes, as are found in most practical sensing applications. The method evades the trade-off between sensitivity and time resolution in coherent sensing.

  14. Online track reconstruction at hadron colliders

    International Nuclear Information System (INIS)

    Amerio, Silvia; Bettini, Marco; Nicoletto, Marino; Crescioli, Francesco; Bucciantonio, Martina; DELL'ORSO, Mauro; Piendibene, Marco; VOLPI, Guido; Annovi, Alberto; Catastini, Pierluigi; Giannetti, Paola; Lucchesi, Donatella

    2010-01-01

    Real time event reconstruction plays a fundamental role in High Energy Physics experiments. Reducing the rate of data to be saved on tape from millions to hundreds per second is critical. In order to increase the purity of the collected samples, rate reduction has to be coupled with the capability to simultaneously perform a first selection of the most interesting events. A fast and efficient online track reconstruction is important to effectively trigger on leptons and/or displaced tracks from b-quark decays. This talk will be an overview of online tracking techniques in different HEP environments: we will show how H1 experiment at HERA faced the challenges of online track reconstruction implementing pattern matching and track linking algorithms on CAMs and FPGAs in the Fast Track Processor (FTT). The pattern recognition technique is also at the basis of the Silicon Vertex Trigger (SVT) at the CDF experiment at Tevatron: coupled to a very fast fitting phase, SVT allows to trigger on displaced tracks, thus greatly increasing the efficiency for the hadronic B decay modes. A recent upgrade of the SVT track fitter, the Giga-fitter, can perform more than 1 fit/ns and further improves the CDF online trigger capabilities at high luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the ATLAS experiment, based on the Giga-fitter architecture and designed to provide high quality tracks reconstructed over the entire detector in time for a Level-2 trigger decision.luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the Atlas experiment, based on the Giga-fitter architecture and designed to provide high

  15. NMT - A new individual ion counting method: Comparison to a Faraday cup

    Science.gov (United States)

    Burton, Michael; Gorbunov, Boris

    2018-03-01

    Two sample detectors used to analyze the emission from Gas Chromatography (GC) columns are the Flame Ionization Detector (FID) and the Electron Capture Detector (ECD). Both of these detectors involve ionization of the sample molecules and then measuring electric current in the gas using a Faraday cup. In this paper a newly discovered method of ion counting, Nanotechnology Molecular Tagging (NMT) is tested as a replacement to the Faraday cup in GCs. In this method the effective physical volume of individual molecules is enlarged up to 1 billion times enabling them to be detected by an optical particle counter. It was found that the sensitivity of NMT was considerably greater than the Faraday cup. The background in the NMT was circa 200 ions per cm3, corresponding to an extremely low electric current ∼10-17 A.

  16. Application of Faraday cup array detector in measurement of electron-beam distribution homogeneity

    International Nuclear Information System (INIS)

    Xu Zhiguo; Wang Jinchuan; Xiao Guoqing; Guo Zhongyan; Wu Lijie; Mao Ruishi; Zhang Li

    2005-01-01

    It is described that a kind of Faraday cup array detector, which consists of Faraday cup, suppressor electrode insulation PCB board, Base etc. The homogeneity of electron-beam distribution is measured and the absorbed dose for the irradiated sample is calculated. The results above provide the important parameters for the irradiation experiment and the improvement for the quality of electron beam. (authors)

  17. Nondestructive measurement of the mobility in semiconductors by means of the microwave Faraday effect

    International Nuclear Information System (INIS)

    Musil, F.; Zacek, F.; Buerger, A.; Karlovsky, J.

    1976-01-01

    The measurement is described of electron mobility in semiconducting plates placed between two cylindrical antennas with diameter d approximately equal to 0.75lambda 0 by means of the microwave Faraday effect. This system makes it possible (i) to measure the Faraday rotation in semiconductina plates of arbitrary transverse dimensions, greater or at least equal to the diameter of dielectric antennas, (ii) to evaluate the unknown value of the charge carrier mobility from the measured rotation in an unbounded solid state plasma slab approximation. The measurement of Faraday rotation in n-type Ge plates is reported. The comparison of the experimental data with the theory shows good agreement. (author)

  18. Nurse Practitioners' attitude to nutritional challenges dealing with the patients' nutritional needs and ability to care for themselves in a fast track program

    DEFF Research Database (Denmark)

    Graarup, Jytte; Pedersen, Preben Ulrich; Bjerrum, Merete

    2014-01-01

    Background: Nutrition plays an important role to the success of fast track programs, but under nutrition are still reported. Nutritional care seems to be a low priority among nurses even though it is well-known that insufficient nutrition has severe consequences for the patients. The aim is to re......Background: Nutrition plays an important role to the success of fast track programs, but under nutrition are still reported. Nutritional care seems to be a low priority among nurses even though it is well-known that insufficient nutrition has severe consequences for the patients. The aim...... is to report to what extent a training program has made Nutritional Nurse Practitioners aware of the nutritional care for short-term hospitalized patients, and how they deal with patients’ nutritional needs and ability to provide self-care in the context of a fast track program. Methods: Deductive content...... analysis was used to analyse data from four focus group interviews. Sixteen Nutritional Nurse Practitioners from either medical or surgery wards participated. The Nutritional Nurse Practitioners were interviewed twice. The interviews were recorded and verbally transcribed. Results: In the Nutritional Nurse...

  19. Fast-track surgery: A new concept of perioperative management of surgical patients

    Directory of Open Access Journals (Sweden)

    Gabriel Rodrigues

    2013-01-01

    Full Text Available In the past few decades, surgery has advanced greatly because of an improved understanding of perioperative pathophysiology, development of minimally invasive operative techniques and advanced anaesthetic techniques. Fewer operations are requiring extended periods of hospital stay and a growing number of procedures are performed on an ambulatory basis. The pressure on medical systems is continuously growing as a result of economic constraints, increasing numbers of patients undergoing surgical procedures and greater patient autonomy. Patient awareness is steadily increasing along with their participation in their own care, leading to expectations of a higher standard of care. This has led to the development of a new concept of fast-track surgery.

  20. Midplane Faraday rotation: A densitometer for large tokamaks

    International Nuclear Information System (INIS)

    Jobes, F.C.; Mansfield, D.K.

    1992-01-01

    The density in a large tokamak such as International Thermonuclear Experimental Reactor (ITER), or any of the proposed future US machines, can be determined by measuring the Faraday rotation of a 10.6 μm laser directed tangent to the toroidal field. If there is a horizontal array of such beams, then n e (R) can be readily obtained with a simple Abel inversion about the center line of the tokamak. For a large machine, operated at a full field of 30 T m and a density of 2x10 20 /m 3 , the rotation angle would be quite large-about 60 degree for two passes. A layout in which a single laser beam is fanned out in the horizontal midplane of the tokamak, with a set of retroreflectors on the far side of the vacuum vessel, would provide good spatial resolution, depending only upon the number of reflectors. With this proposed layout, only one window would be needed. Because the rotation angle is never more than 1 ''fringe,'' the data is always good, and it is also a continuous measurement in time. Faraday rotation is dependent only upon the plasma itself, and thus is not sensitive to vibration of the optical components. Simulations of the expected results show that ITER, or any large tokamak, existing or proposed, would be well served even at low densities by a midplane Faraday rotation densitometer of ∼64 channels

  1. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte; Jacobsen, Steffen

    2008-01-01

    BACKGROUND AND PURPOSE: Very few studies have focused on patient characteristics that influence length of stay (LOS) in fast-track total hip (THR) and knee arthroplasty (TKR). The aim of this prospective study was to identify patient characteristics associated with LOS and patient satisfaction...... after total hip and knee replacement surgery. PATIENTS AND METHODS: Between September 2003 and December 2005, 712 consecutive, unselected patients (440 women) with a mean age of 69 (31-91) years were admitted for hip and knee replacement surgery at our specialized fast-track joint replacement unit....... Epidemiological, physical, and perioperative parameters were registered and correlated to LOS and patient satisfaction. RESULTS: 92% of the patients were discharged directly to their homes within 5 days, and 41% were discharged within 3 days. Age, sex, marital status, co-morbidity, preoperative use of walking...

  2. The Effects of the Fast Track Preventive Intervention on the Development of Conduct Disorder Across Childhood

    OpenAIRE

    2011-01-01

    The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social cognitive skills, reading, home visiting, mentoring, and classroom curricula. Outcomes included psychiatric diagnoses after grades 3, 6, 9, and 12 for...

  3. Fast Tracker : A Hardware Real Time Track Finder for the ATLAS Trigger System

    CERN Document Server

    Kimura, N; The ATLAS collaboration

    2013-01-01

    The Large Hadron Collider (LHC) after the 2013-­‐2014 shutdown period is expected to improve the yet impressive performance obtained up to this year: collisions’ energy will increase to 14 TeV and instantaneous luminosity will reach and then overcome 10^34 cm‐2s‐1, with a bunch crossing period of 25 ns. The LHC experiments will need to adapt to the more crowded events, maintaining the physics output and the quality of the final results. The pileup higher than the LHC run 1, with peaks expected to reach 50 or more, will make more difficult to have efficient online selection of rare events based mostly on calorimeters and muon detectors as it is done now. A more extensive use of the information collected by the tracking detector will allow building more robust selections, limiting the degradation effects due to the high pileup. We report on the development of the Fast Tracker (FTK) processor for the ATLAS experiment, devoted to reconstruct tracks with transverse momentum above 1 GeV in the whole detect...

  4. Measurements of coronal Faraday rotation at 4.6 R ☉

    International Nuclear Information System (INIS)

    Kooi, Jason E.; Fischer, Patrick D.; Buffo, Jacob J.; Spangler, Steven R.

    2014-01-01

    Many competing models for the coronal heating and acceleration mechanisms of the high-speed solar wind depend on the solar magnetic field and plasma structure in the corona within heliocentric distances of 5 R ☉ . We report on sensitive Very Large Array (VLA) full-polarization observations made in 2011 August, at 5.0 and 6.1 GHz (each with a bandwidth of 128 MHz) of the radio galaxy 3C 228 through the solar corona at heliocentric distances of 4.6-5.0 R ☉ . Observations at 5.0 GHz permit measurements deeper in the corona than previous VLA observations at 1.4 and 1.7 GHz. These Faraday rotation observations provide unique information on the magnetic field in this region of the corona. The measured Faraday rotation on this day was lower than our a priori expectations, but we have successfully modeled the measurement in terms of observed properties of the corona on the day of observation. Our data on 3C 228 provide two lines of sight (separated by 46'', 33,000 km in the corona). We detected three periods during which there appeared to be a difference in the Faraday rotation measure between these two closely spaced lines of sight. These measurements (termed differential Faraday rotation) yield an estimate of 2.6-4.1 GA for coronal currents. Our data also allow us to impose upper limits on rotation measure fluctuations caused by coronal waves; the observed upper limits were 3.3 and 6.4 rad m –2 along the two lines of sight. The implications of these results for Joule heating and wave heating are briefly discussed.

  5. Development of an external Faraday cup for beam current measurements

    International Nuclear Information System (INIS)

    Kim, Kye-Ryung; Jung, Myung-Hwan; Ra, Se-Jin; Lee, Seok-Ki

    2010-01-01

    In general, beam current measurements are very important for many kinds of experiments using highly energetic particle beams at accelerators, such as cyclotrons, linacs, etc. The Faraday cup is known to be one of the most popular beam current measurement tools. We developed an external Faraday cup to measure the beam current at a dedicated beam line for low-flux experiments installed at the MC-50 cyclotron of Korea Institute of Radiological and Medical Sciences (KIRAMS). It was designed for external beam current measurements and is composed of a vacuum chamber, an entrance window, a collimator, a electrostatic suppressor ring, and a cup. The window is made of 75-um-thick Kapton film, and the diameter of the collimator is 10 mm or 20 mm. The ring and the cup has 5-cm inner diameters, and the thickness of the bottom of the cup is 2 cm, which is enough to absorb the total proton energy up to 45 MeV. Using this external Faraday cup, we measured the beam current from the cyclotron, and we compared measured flux to the results from film dosimetry using GAF films.

  6. Demonstration of a mid-infrared NO molecular Faraday optical filter.

    Science.gov (United States)

    Wu, Kuijun; Feng, Yutao; Li, Juan; Yu, Guangbao; Liu, Linmei; Xiong, Yuanhui; Li, Faquan

    2017-12-11

    A molecular Faraday optical filter (MFOF) working in the mid-infrared region is realized for the first time. NO molecule was used as the working material of the MFOF for potential applications in atmospheric remote sensing and combustion diagnosis. We develop a complete theory to describe the performance of MFOF by taking both Zeeman absorption and Faraday rotation into account. We also record the Faraday rotation transmission (FRT) signal using a quantum cascade laser over the range of 1,820 cm -1 to 1,922 cm -1 and calibrate it by using a 101.6 mm long solid germanium etalon with a free spectral range of 0.012 cm -1 . Good agreement between the simulation results and experimental data is achieved. The NO-MFOF's transmission characteristics as a function of magnetic field and pressure are studied in detail. Both Comb-like FRT spectrum and single branch transmission spectrum are obtained by changing the magnetic field. The diversity of FRT spectrum expands the range of potential applications in infrared optical remote sensing. This filtering method can also be extended to the lines of other paramagnetic molecules.

  7. Effects of interband transitions on Faraday rotation in metallic nanoparticles.

    Science.gov (United States)

    Wysin, G M; Chikan, Viktor; Young, Nathan; Dani, Raj Kumar

    2013-08-14

    The Faraday rotation in metallic nanoparticles is considered based on a quantum model for the dielectric function ϵ(ω) in the presence of a DC magnetic field B. We focus on effects in ϵ(ω) due to interband transitions (IBTs), which are important in the blue and ultraviolet for noble metals used in plasmonics. The dielectric function is found using the perturbation of the electron density matrix due to the optical field of the incident electromagnetic radiation. The calculation is applied to transitions between two bands (d and p, for example) separated by a gap, as one finds in gold at the L-point of the Fermi surface. The result of the DC magnetic field is a shift in the effective optical frequency causing IBTs by ±μBB/ħ, where opposite signs are associated with left/right circular polarizations. The Faraday rotation for a dilute solution of 17 nm diameter gold nanoparticles is measured and compared with both the IBT theory and a simpler Drude model for the bound electron response. Effects of the plasmon resonance mode on Faraday rotation in nanoparticles are also discussed.

  8. Faraday-Active Fabry-Perot Resonator: Transmission, Reflection, and Emissivity

    Science.gov (United States)

    Liptuga, Anatoliy; Morozhenko, Vasyl; Pipa, Viktor; Venger, Evgen; Kostiuk, Theodor

    2011-01-01

    The propagation of light within a semiconductor Faraday-active Fabry-Perot resonator (FAFR) is investigated theoretically and experimentally. It is shown that an external magnetic field radically changes the angular and spectral characteristics of transmission, reflection and emissivity of the resonator not only for polarized, but also for unpolarized light. Suppression of interference patterns and phase inversion of the interference extrema were observed in both monochromatic and polychromatic light. The investigations were carried out for the plane-parallel plates of n-InAs in the spectral range of free charge carrier absorption. The results can be used to create new controllable optical and spectroscopic devices for investigation of Faraday-active material properties and for control of parameters of plane-parallel layers and structures.

  9. Fast TPC Online Tracking on GPUs and Asynchronous Data Processing in the ALICE HLT to facilitate Online Calibration

    International Nuclear Information System (INIS)

    Rohr, David; Gorbunov, Sergey; Krzewicki, Mikolaj; Breitner, Timo; Kretz, Matthias; Lindenstruth, Volker

    2015-01-01

    ALICE (A Large Heavy Ion Experiment) is one of the four major experiments at the Large Hadron Collider (LHC) at CERN, which is today the most powerful particle accelerator worldwide. The High Level Trigger (HLT) is an online compute farm of about 200 nodes, which reconstructs events measured by the ALICE detector in real-time. The HLT uses a custom online data-transport framework to distribute data and workload among the compute nodes.ALICE employs several calibration-sensitive subdetectors, e.g. the TPC (Time Projection Chamber). For a precise reconstruction, the HLT has to perform the calibration online. Online- calibration can make certain Offline calibration steps obsolete and can thus speed up Offline analysis. Looking forward to ALICE Run III starting in 2020, online calibration becomes a necessity.The main detector used for track reconstruction is the TPC. Reconstructing the trajectories in the TPC is the most compute-intense step during event reconstruction. Therefore, a fast tracking implementation is of great importance. Reconstructed TPC tracks build the basis for the calibration making a fast online-tracking mandatory.We present several components developed for the ALICE High Level Trigger to perform fast event reconstruction and to provide features required for online calibration.As first topic, we present our TPC tracker, which employs GPUs to speed up the processing, and which bases on a Cellular Automaton and on the Kalman filter. Our TPC tracking algorithm has been successfully used in 2011 and 2012 in the lead-lead and the proton-lead runs. We have improved it to leverage features of newer GPUs and we have ported it to support OpenCL, CUDA, and CPUs with a single common source code. This makes us vendor independent.As second topic, we present framework extensions required for online calibration. The extensions, however, are generic and can be used for other purposes as well. We have extended the framework to support asynchronous compute chains

  10. Faraday rotation in an electron-positron plasma containing a fraction of ions

    International Nuclear Information System (INIS)

    Hall, J.O.; Shukla, P.K.

    2005-01-01

    The Faraday rotation in a magnetized electron-positron plasma containing a fraction of ions is investigated by using a multifluid description. It is shown that the Faraday rotation for circularly polarized electromagnetic waves with frequencies much larger than the electron/positron plasma and electron gyrofrequencies is proportional to the ion number density and the magnitude of the ambient magnetic-field strength. The results are relevant for astrophysical observations and diagnostics of laboratory electron-positron-ion magnetoplasmas

  11. Mini biased collimated faraday cups for measurement of intense pulsed ion beams

    International Nuclear Information System (INIS)

    He Xiaoping; Shi Lei; Zhang Jiasheng; Qiu Aici

    2000-01-01

    An analysis of principle of a biased Faraday cup for measuring ion beams density and the main reasons related to the measuring accuracy were presented. An array of mini biased collimated Faraday cups was manufactured for the measurement of ion beam density of a compact 200 keV high power ion beam source. In the experiments the maximum density of ion beam was in the center of the beam, and it was about 170 A/cm 2

  12. Faraday rotation by the undisturbed bulk and by photoinduced giant polarons in EuTe

    Science.gov (United States)

    Henriques, A. B.; Usachev, P. A.

    2017-11-01

    A quantum mechanical model is developed for the Faraday effect in europium telluride, for photons of energy within the transparency gap. The model is based on the well known band edge electronic energy states in EuTe. A concise expression for the Verdet constant is obtained, determined by few parameters already available in the literature. The Verdet constant adopted here, defined by the ratio between the Faraday rotation angle and the magnetization, is in effect temperature independent. Its dependence on the photon energy and applied magnetic field is in excellent agreement with published results. Below 3 T the Verdet constant is also nearly independent on field, but above 3 T at low temperatures it increases due to the band gap redshift. The model is used to calculate the photoinduced Faraday rotation associated with photoinduced giant magnetic polarons in EuTe. The theoretical photoinduced Faraday rotation excitation describes quite well the main features seen experimentally. Due to the common band-edge electronic energy structure, the model reported here could be extended to all other europium chalcogenides.

  13. MANAJEMEN RISIKO PADA PROYEK KONSTRUKSI DENGAN METODE FAST TRACK STUDI KASUS PROYEK QUNCI VILLAS DAN PUTRI NAGA KOMODO

    Directory of Open Access Journals (Sweden)

    I Gusti Ketut Wirawan

    2015-07-01

    Full Text Available The rapid economic development such as now day, it need a construction method that may provide a facility faster and less cost. Therefore, fast track method has been widely applied in project management as happened in Qunci Villas Project at Lombok and Putri Naga Komodo Project at Loh Liang of Komodo Island. Fast track construction method has potential risks that can interfere the success of the project. This study aims to identify the risks, especially the mayor risk, to formulate the mitigation action, and to determine the risk ownership. This study was conducted using qualitative descriptive method by identifying the risks arising during the implementation of the fast track method on Qunci Villas and Putri Naga Komodo Projects through the study of literature, brainstorming, interview using questionnaires to those who knew or were involved in the project. So the frequency and magnitude of the consequences of each risk can be known. Then the risk assessment can be conducted to determine the mayor risk and the minor risk. Then determining mitigation action for the mayor risk to reduce the negative impact that may arise. Then allocating the risk ownership in other to the mitigation action can be handled properly. The risk identified totaled 25 risks consisting of : 1 risk (4% which was medium risk rating,  6 risks (24% which were high risk rating, and 18 risks (72% which were extreme risk rating. The mayor risk amounted to 24 risks (96%. The mayor risk which were high risk rating consisting of : 1 planning risk, 3 technical risks, 1 project risk and 1 criminal risk. While mayor risk which were extreme risk rating consisting of : 5 technical risks, 10 project risks, 2 financial risks, and 1 human risk. Mitigation action were handled by reducing likelihood and consequence. The most risks ownership were allocated to the contractor.

  14. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.Y.; Seidman, D.N.

    1977-07-01

    The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA) which serves as the basis of an internal image intensification system (a gain of greater than 10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion cured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30 keV Ar + ion beam is presented as an illustrative example. This Faraday cup was also employed to observe and measure 30 keV Cr + , Mo + or W + and 18 keV Au + ion beams employed for the in-situ irradiation of field-ion microscope specimens

  15. A magneto-optically modulated CH3OH laser for Faraday rotation measurements in tokamaks

    International Nuclear Information System (INIS)

    Mansfield, D.K.; Johnson, L.C.

    1981-01-01

    Distortion-free intracavity polarization modulation of an optically pumped CH3OH laser is shown to be viable. The possible use of this modulation technique to make a multichannel Faraday rotation measurement on a tokamak device is discussed. In addition, the CdTe Faraday modulator employed in this study is shown to have an anomalously large Verdet constant

  16. Outcomes in smokers and alcohol users after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, Henrik; Hansen, Torben Bæk

    2013-01-01

    and knee arthroplasty. RESULTS: In 3041 consecutive patients, 458 reported smoking and 216 drinking > 2 drinks a day, of which 66 did both. Smokers/alcohol users were younger than non-users (mean age: 64.3 vs. 68.0 years, P  4 days and smoking (odds ratio [95% confidence interval], P) (1.34 [0.92-1.95], 0......BACKGROUND: Smoking and alcohol use impair post-operative outcomes. However, no studies include fast-track surgery, which is a multimodal-enhanced recovery programme demonstrated to improve outcome. We hypothesised that outcome is similar in smokers and alcohol users as in non-users after fast.......127) or alcohol use (0.59 [0.30-1.16], 0.127). Thirty- and ninety-day readmission rate was 6.6% (n = 201) and 9.4% (n = 285). Multiple logistic regression analysis showed an increased risk of readmissions in smokers at 30 (1.60 [1.05-2.44], 0.028) but not 90-day follow-up (1.17 [0.80-1.73], 0.419). No increased...

  17. The Minus Sign in Faraday's Law Revisited

    Science.gov (United States)

    O'Sullivan, Colm; Hurley, Donal

    2013-01-01

    By introducing the mathematical concept of orientation, the significance of the minus sign in Faraday's law may be made clear to students with some knowledge of vector calculus. For many students, however, the traditional approach of treating the law as a relationship between positive scalars and of relying on Lenz's law to provide the information…

  18. Health preemption behind closed doors: trade agreements and fast-track authority.

    Science.gov (United States)

    Crosbie, Eric; Gonzalez, Mariaelena; Glantz, Stanton A

    2014-09-01

    Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies' influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. "Fast-track authority," in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests.

  19. Postoperative anemia and early functional outcomes after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, Øivind; Bandholm, Thomas; Kurbegovic, Sorel

    2016-01-01

    BACKGROUND: Postoperative anemia is prevalent in fast-track hip arthroplasty (THA) where patients are mobilized and discharged early, but whether anemia impairs functional recovery after discharge has not been adequately evaluated previously. This study aimed to evaluate whether postoperative...... anemia influenced recovery of mobility and quality of life (Qol) during the first 2 weeks after discharge from THA. STUDY DESIGN AND METHODS: This was a prospective observational study in 122 THA patients more than 65 years of age. Mobility and Qol were assessed pre- and postoperatively by the 6-minute...... walk test (6MWT; primary outcome), the timed up-and-go test, and the FACT-anemia subscale. Twenty-four-hour mobility at home was assessed by activity monitoring on Days 1 to 6 after discharge. Hemoglobin (Hb) at discharge (HbD) and the Hb decrease from preoperatively (ΔHb) were compared to mobility...

  20. 171. Funcionamiento y resultados del programa de fast-track en el tratamiento de la tetralogía de fallot

    Directory of Open Access Journals (Sweden)

    J. Orrit Palacios

    2010-01-01

    Conclusiones: La corrección completa de la tetralogía de Fallot con el programa de fast-track de anestesia disminuye la ventilación mecánica, la estancia en cuidados intensivos y el tiempo de hospitalización. Asimismo se reducen los costes económicos del tratamiento.

  1. Inverse energy cascade and emergence of large coherent vortices in turbulence driven by Faraday waves.

    Science.gov (United States)

    Francois, N; Xia, H; Punzmann, H; Shats, M

    2013-05-10

    We report the generation of large coherent vortices via inverse energy cascade in Faraday wave driven turbulence. The motion of floaters in the Faraday waves is three dimensional, but its horizontal velocity fluctuations show unexpected similarity with two-dimensional turbulence. The inverse cascade is detected by measuring frequency spectra of the Lagrangian velocity, and it is confirmed by computing the third moment of the horizontal velocity fluctuations. This is observed in deep water in a broad range of wavelengths and vertical accelerations. The results broaden the scope of recent findings on Faraday waves in thin layers [A. von Kameke et al., Phys. Rev. Lett. 107, 074502 (2011)].

  2. A New Method for Analyzing Near-Field Faraday Probe Data in Hall Thrusters

    Science.gov (United States)

    Huang, Wensheng; Shastry, Rohit; Herman, Daniel A.; Soulas, George C.; Kamhawi, Hani

    2013-01-01

    This paper presents a new method for analyzing near-field Faraday probe data obtained from Hall thrusters. Traditional methods spawned from far-field Faraday probe analysis rely on assumptions that are not applicable to near-field Faraday probe data. In particular, arbitrary choices for the point of origin and limits of integration have made interpretation of the results difficult. The new method, called iterative pathfinding, uses the evolution of the near-field plume with distance to provide feedback for determining the location of the point of origin. Although still susceptible to the choice of integration limits, this method presents a systematic approach to determining the origin point for calculating the divergence angle. The iterative pathfinding method is applied to near-field Faraday probe data taken in a previous study from the NASA-300M and NASA-457Mv2 Hall thrusters. Since these two thrusters use centrally mounted cathodes the current density associated with the cathode plume is removed before applying iterative pathfinding. A procedure is presented for removing the cathode plume. The results of the analysis are compared to far-field probe analysis results. This paper ends with checks on the validity of the new method and discussions on the implications of the results.

  3. Far off-resonance laser frequency stabilization using multipass cells in Faraday rotation spectroscopy.

    Science.gov (United States)

    Quan, Wei; Li, Yang; Li, Rujie; Shang, Huining; Fang, Zishan; Qin, Jie; Wan, Shuangai

    2016-04-01

    We propose a far off-resonance laser frequency stabilization method by using multipass cells in Rb Faraday rotation spectroscopy. Based on the detuning equation, if multipass cells with several meters optical path length are used in the conventional Faraday spectroscopy, the detuning of the lock point can be extended much further from the alkali metal resonance. A plate beam splitter was used to generate two different Faraday signals at the same time. The transmitted optical path length was L=50  mm and the reflected optical path length was 2L=100  mm. When the optical path length doubled, the detuning of the lock points moved further away from the atomic resonance. The temperature dependence of the detuning of the lock point was also analyzed. A temperature-insensitive lock point was found near resonance when the cell temperature was between 110°C and 130°C. We achieved an rms fluctuation of 0.9 MHz/23 h at a detuning of 0.5 GHz. A frequency drift of 16 MHz/h at a detuning of -5.6  GHz and 4 MHz/h at a detuning of -5.2  GHz were also obtained for the transmitted and reflected light Faraday signal.

  4. Interaction of vortex lattice with ultrasound and the acoustic Faraday effect

    International Nuclear Information System (INIS)

    Dominguez, D.; Bulaevskii, L.; Ivlev, B.; Maley, M.; Bishop, A.R.

    1995-01-01

    The interaction of sound with the vortex lattice is considered for high-T c superconductors, taking into account pinning and electrodynamic forces between vortices and crystal displacements. At low temperatures the Magnus force results in the acoustic Faraday effect; the velocity of sound propagating along the magnetic field depends on the polarization. This effect is linear in the Magnus force and magnetic field in crystals with equivalent a and b axes for a field parallel to the c axis. In the thermally activated flux flow regime, the Faraday effect is caused by electric and magnetic fields induced by vortices and acting on ions

  5. Analysis of etchants behavior on the electrochemical etching amplification of fast-neutron-induced recoil particle tracks in polycarbonate

    International Nuclear Information System (INIS)

    Masnadi Shirazi Nezhad, K.

    1979-08-01

    The composition, concentration, and temperature of etchant are important parameters controlling electrochemical etching (ECE) amplification of charged particle tracks in polymers. These parameters were further studied for sohralir polycarbonate neutron dosimeter (Sohrabi 1974), using potassium hydroxide (KOH) and sodium hydroxide (NaOH) solutions, and a mixture of potassium hydroxide, ethanol, and water (PEW solution), at different concentrations applying a field strength of 32KV/cm at 2KHz frequency using 250 μ thick polycarbonate exposed to fast neutrons. The recoal track density per rad of neutrons, in general, was found to increase by increasing the etchant concentration reaching a semi-platean after which it increases again. This increase is up to a concentration at which a track removing process occurs and no tracks have been amplified anymore. This track removing process occurred at about 11 normality in both KOH (50% by weight) and NaOH (30% by weight) solution at 25degC. The mean track diameter, in general, passed through a cyclic variation having a maximun and a minimum. For NaOH solution, the track removing process occurred at the minimum point. In the three regions of the track diameter curve the tracks appear in different shapes especially in KOH solution. The PEW solution at its optimum conditions was more effective in terms of both sensitivity, track diameter and a shorter period of etching. The chemical mechanism of etching process may be explained to be a ''saponification'' process. These studies further support the adequacy of Sohrabi dosimeter for routing health physics and radiation research applications. The above parameters are further discussed and the results as well as the advantages and disadvantages of the above etchants are given. (author)

  6. Magneto-optically modulated CH/sub 3/OH laser For faraday rotation measurements in tokamaks

    International Nuclear Information System (INIS)

    Mansfield, D.K.; Johnson, L.C.

    1981-01-01

    Distortion-free intracavity polarization modulation of an optically pumped CH/sub 3/OH laser is shown to be viable. The possible use of this modulation technique to make a multichannel Faraday rotation measurement on a Tokamak device is discussed. In addition, the CdTe Faraday modulator employed in this study is shown to have an anomalously large Verdet constant. 12 refs

  7. Faraday screen sputtering on TPX

    International Nuclear Information System (INIS)

    Ehst, D.A.

    1994-12-01

    The TPX design stipulates that the ion-cyclotron resonance frequency (ICRF) antenna must have a Faraday screen (FS). The author considers here possible low Z coatings for the screen, as well as sputtering behavior of the Ni and Ti substrates. The theory of rf-induced sputtering has been developed, and he follows those theoretical approaches. The author's emphasis will be on both impurity generation as a possible source of increased Z eff , and also on actual erosion-lifetime of the materials under worst case conditions

  8. A Note on Faraday Paradoxes

    CERN Document Server

    Auchmann, Bernhard; Russenschuck, Stephan

    2014-01-01

    The validity of the flux rule to determine the electromotive force in a cycle, epsilon = -d Phi/dt, has been the subject of a large amount of controversy since the beginning of electrical technology. Although most authors reach correct conclusions for a class of problems called Faraday paradoxes, the arguments that are used vary and often rely on ad-hoc physical reasoning. A didactic and insightful treatment should be based solely on Maxwell's equations, the constitutive laws, and a detailed study of the mathematics involved.

  9. Reflections of a Faraday Challenge Day Leader

    Science.gov (United States)

    Sewell, Keira

    2014-01-01

    Keira Sewell has just finished her second year as a Challenge Leader for the Faraday Challenge, a STEM-based scheme run by the Institution of Engineering and Technology. Aimed at 12-13 year-old students, its purpose is to engage students in future careers in engineering. Each year, a new challenge is held in over sixty schools and universities…

  10. Giant Faraday rotation in Bi(x)Ce(3-x)Fe5O12 epitaxial garnet films.

    Science.gov (United States)

    Chandra Sekhar, M; Singh, Mahi R; Basu, Shantanu; Pinnepalli, Sai

    2012-04-23

    Thin films of Bi(x)Ce(3-x)Fe(5)O(12) with x = 0.7 and 0.8 compositions were prepared by using pulsed laser deposition. We investigated the effects of processing parameters used to fabricate these films by measuring various physical properties such as X-ray diffraction, transmittance, magnetization and Faraday rotation. In this study, we propose a phase diagram which provides a suitable window for the deposition of Bi(x)Ce(3-x)Fe(5)O(12) epitaxial films. We have also observed a giant Faraday rotation of 1-1.10 degree/µm in our optimized films. The measured Faraday rotation value is 1.6 and 50 times larger than that of CeYIG and YIG respectively. A theoretical model has been proposed for Faraday rotation based on density matrix method and an excellent agreement between experiment and theory is found. © 2012 Optical Society of America

  11. Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST.

    Science.gov (United States)

    Zou, Z Y; Liu, H Q; Ding, W X; Chen, J; Brower, D L; Lian, H; Wang, S X; Li, W M; Yao, Y; Zeng, L; Jie, Y X

    2018-01-01

    A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°-10° to 1°-2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

  12. A method for the measurement of fission rates in fast neutron fields using solid state track detectors

    International Nuclear Information System (INIS)

    Hansen, W.; Vogel, W.

    1984-04-01

    Solid state track detectors (SSTDs) are increasingly used for the registration of radiation in different fields of nuclear physics. Because of their small sizes and masses and the absence of any electronics during exposure SSTDs do not cause distortions in the system to be investigated and are useful for measurements at such places being difficult of access. The elaboration of a method is described for fission rate measurements in fast neutron fields applying SSTDs and different fissionable isotopes which were electrodeposited on stainless steel backings. Experiences of the electrodeposition and results of quality checks are presented. The evaluation of the etched tracks is performed with spark counter technique. The dependence of the counting result on essential influence parameters is discussed. (author)

  13. Michael Faraday and the concept of atomic structure

    International Nuclear Information System (INIS)

    Pocock, R.F.

    1991-01-01

    Written to commemorate the bicentenary of Faraday's birth, this article surveys his influence on atomic theory during the 19th and early 20th centuries. It identifies which developments were derived from projects which he had started; it shows that his ideas and methods determined the direction of researches which he had not himself initiated. The account is in the form of a chronological narrative. This is based entirely on published sources, and the treatment is non-mathematical. In consequence it contains no new factual data. The presentation of Faraday's work in this particular context is, however, original. Although not covering studies of the nucleus - which were mostly later than the period considered -this article describes the origins of modern theories of atomic structure reasonably completely. It is a useful overview for engineers unfamiliar with details of the history of physics. In addition, it is a case-study of the persistence of scientific ideas in researches occupying a century or more. (author)

  14. Faraday Rotation Studies of Indium Antimonide and CADMIUM(1-X) Manganese(x) Telluride

    Science.gov (United States)

    Jimenez Gonzalez, Hector J.

    Faraday rotation has been studied in two material systems: narrow-gap InSb and wide-gap Cd_ {1-x}Mn_{x}Te. The measurements were done in the infrared region using high magnetic fields up to 150 kG. The Faraday rotation of n-type InSb has been measured for wavelengths between 8.0 and 13.0 μm at 9 K, using magnetic fields up to 150 kG. Measurements were made on samples with nominal carrier concentrations of 1 times 10^{14 }, 6 times 10 ^{14}, 1 times 10^{15}, and 5 times 10^{15} cm^{-3}. The experimental results have been successfully analyzed in terms of intraband and interband transitions at the Gamma point in the Brillouin zone, using a quantum-mechanical treatment. In this approach, there are three contributions to the Faraday rotation: (a) interband, (b) plasma, and (c) spin contributions. The interband contribution is dominant in the low concentration samples where the plasma and spin contributions, which are due to the free carriers, are small. At high carrier concentrations the spin and plasma contributions are dominant. In the low-magnetic -field regime the interband and plasma contributions are linearly proportional to the magnetic field and become small. This makes the spin contribution the leading contribution to the Faraday rotation at low magnetic fields. The 4 -band k cdot p Pidgeon and Brown model was used to calculate the energy levels and the matrix elements for these transitions. Quantum oscillatory effects were observed at low magnetic field. Cyclotron resonance absorption was observed in all samples for wavelengths _sp{~}{>}16.0 mum. The Faraday rotation of Cd_{1 -x}Mn_{x}Te has been measured for x = 0 to 0.27 at 300 and 77 K for photon energies between 0.1 and 1.5 eV, corresponding to wavelengths of 12.0 and 0.8 mum, respectively. We have developed a multioscillator model for the Faraday rotation using an analytical expression for the refractive index that includes contributions from interband transitions at the Gamma, L, and X points of the

  15. One-Piece Faraday Generator: A Paradoxical Experiment from 1851

    Science.gov (United States)

    Crooks, M. J.; And Others

    1978-01-01

    Describes an experiment based on Faraday's one-piece generator, where the rotating disk is replaced by a cylindrical permanent magnet. Explains the apparent paradox that an observer in an inertial frame could measure his absolute velocity. (GA)

  16. Diagnostics of the solar corona from comparison between Faraday rotation measurements and magnetohydrodynamic simulations

    International Nuclear Information System (INIS)

    Le Chat, G.; Cohen, O.; Kasper, J. C.; Spangler, S. R.

    2014-01-01

    Polarized natural radio sources passing behind the Sun experience Faraday rotation as a consequence of the electron density and magnetic field strength in coronal plasma. Since Faraday rotation is proportional to the product of the density and the component of the magnetic field along the line of sight of the observer, a model is required to interpret the observations and infer coronal structures. Faraday rotation observations have been compared with relatively ad hoc models of the corona. Here for the first time we compare these observations with magnetohydrodynamic (MHD) models of the solar corona driven by measurements of the photospheric magnetic field. We use observations made with the NRAO Very Large Array of 34 polarized radio sources occulted by the solar corona between 5 and 14 solar radii. The measurements were made during 1997 May, and 2005 March and April. We compare the observed Faraday rotation values with values extracted from MHD steady-state simulations of the solar corona. We find that (1) using a synoptic map of the solar magnetic field just one Carrington rotation off produces poorer agreements, meaning that the outer corona changes in the course of one month, even in solar minimum; (2) global MHD models of the solar corona driven by photospheric magnetic field measurements are generally able to reproduce Faraday rotation observations; and (3) some sources show significant disagreement between the model and the observations, which appears to be a function of the proximity of the line of sight to the large-scale heliospheric current sheet.

  17. A Faraday rotation search for magnetic fields in quasar damped Ly alpha absorption systems

    Science.gov (United States)

    Oren, Abraham L.; Wolfe, Arthur M.

    1995-01-01

    We present the results of a Faraday rotation survey of 61 radio-bright QSOs conducted at the National Radio Astronomy Observatory (NRAO) Very Large Array (VLA). The Galactic contribution to the Faraday rotation is estimated and subtracted to determine the extragalactic rotation measure (RRM) for each source. Eleven of these QSOs are known to exhibit damped Ly alpha absorption. The rate of incidence of significant Faraday rotation of these 11 sources is compared to the remaining 50 and is found to be higher at the 99.8% confidence level. However, as this is based upon only two detections of Faraday rotation in the damped Ly alpha sample, the result is only tentative. If the two detections in the damped Ly alpha sample are dug to the absorbing systems, then the inferred rotation measure induced by these systems is roughly 250 rad/sq m. The two detections were for the two lowest redshift absorbers in the sample. We find that a rotation measure of 250 rad/sq m would have gone undetected for any other absorber in the damped Ly alpha sample due to the 1/(1 + 2) squared dilution of the observed RRM with redshift. Thus the data are consistent with, but do not prove, the hypothesis that Faraday rotation is a generic property of damped Ly alpha absorbers. We do not confirm the suggestion that the amplitude of RRMs increases with redshift. Rather, the data are consistent with no redshift evolution. We find that the uncertainty in the estimation of the Galactic rotation measure (GRM) is a more serious problem than previously realized for extra-galactic Faraday rotation studies of QSO absorbers. A careful analysis of current methods for estimating GRM indicate that it can be determined to an accuracy of about 15 - 20 rad/sq m. Previous studies underestimated this uncertainty by more than a factor of 2. Due to this uncertainty, rotation measures such as we suspect are associated with damped Ly alpha absorption systems can only be detected at redshifts less than z approximately

  18. Self-Induced Faraday Instability Laser

    Science.gov (United States)

    Perego, A. M.; Smirnov, S. V.; Staliunas, K.; Churkin, D. V.; Wabnitz, S.

    2018-05-01

    We predict the onset of self-induced parametric or Faraday instabilities in a laser, spontaneously caused by the presence of pump depletion, which leads to a periodic gain landscape for light propagating in the cavity. As a result of the instability, continuous wave oscillation becomes unstable even in the normal dispersion regime of the cavity, and a periodic train of pulses with ultrahigh repetition rate is generated. Application to the case of Raman fiber lasers is described, in good quantitative agreement between our conceptual analysis and numerical modeling.

  19. Inhibiting Interference - a grounded theory of health professionals' pattern of behaviour related to the relatives of older patients in fast-track treatment programmes

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten

    2014-01-01

    AIM: To generate a grounded theory explaining health professionals' pattern of behaviour and experience related to the relatives of older patients in fast-track treatment programmes during total joint replacement. BACKGROUND: Health professionals uphold standardised care for patients, and effect...... on quality is seen when relatives support patients during total joint replacement. Since health professionals often have problematic relationships with relatives, knowledge is needed of the health professionals' pattern of behaviour in relation to relatives of older patients in fast-track treatment programme....... DESIGN: Grounded theory according to Glaser's methodology was used to generate substantive theory of health professionals' pattern of behaviour. METHODS: Data were collected from 2010 to 2011 by 44 health professionals in orthopaedic wards at two Danish hospitals. Data from nonparticipant observations...

  20. Study of Charge Distribution in a Dust Beam using a Faraday Cup Assembly

    International Nuclear Information System (INIS)

    Kausik, S.S.; Dutta, P.; Chakraborty, M.; Kakati, M.; Saikia, B.K.

    2005-01-01

    A Faraday cup assembly is employed to study the charge distribution in a dust beam. The Faraday Cup scans the dust beam across its diameter and the dust particle current is noted in an Electrometer. The variation of the pico ampere current, carried by the charged dust particles in the beam, is studied with change in the gas pressure. The observations provide an insight into the variation of the charge to mass ratio in a dust beam

  1. Cyclo-oxygenase 2 inhibitors and the risk of anastomotic leakage after fast-track colonic surgery

    DEFF Research Database (Denmark)

    Holte, K; Andersen, Jens; Jakobsen, D Hjort

    2009-01-01

    -oxygenase inhibitor for postoperative analgesia. METHODS: Patients with anastomotic leakage following a standard fast-track procotol between April 1997 and May 2006 were identified from a prospective, consecutive database. During this period there were two changes in perioperative management: cessation......BACKGROUND: Anastomotic leakage occurs after 3-6 per cent of colonic resections. The influence of analgesic agents is largely unknown. This study determined the rate of anastomotic leakage in a series of patients who had colonic surgery over a 9-year period with or without use of a cyclo...

  2. Spin-flip transition and Faraday effect in antiferromagnet KMnF3 in megagauss magnetic field

    International Nuclear Information System (INIS)

    Mukhin, A.A.; Plis, V.I.; Popov, A.I.; Zvezdin, A.K.; Platonov, V.; Tatsenko, O.M.

    1998-01-01

    Faraday effect in the antiferromagnet KMnF 3 has been investigated in pulse explosive fields up to 500 T at T=78 K. The laser wavelength 0.63 μm was used in the experiment. The magnetic field dependence of Faraday rotation in this antiferromagnet shows a unique feature of a lack of saturation effect in the fields up to 500 T whereas critical field of spin-flip transition is about 120 T. The theoretical analysis of microscopic nature of Faraday rotation, including the diamagnetic, magneto-dipole and paramagnetic mechanisms has been performed. The strong competition of these mechanisms is important to explain the extremely small value of the effect and its unusual magnetic field dependence

  3. Soft X-Ray Magneto-optical Faraday Effect around Ni M2,3 Edges

    International Nuclear Information System (INIS)

    Kai, Chen; Ming-Qi, Cui; Fen, Yan; Li-Juan, Sun; Lei, Zheng; Chen-Yan, Ma; Shi-Bo, Xi; Yi-Dong, Zhao; Jia, Zhao

    2008-01-01

    We present magneto-optical (MO) Faraday spectra measured around the M 2,3 edges (60–70eV) of Ni films at the Beijing Synchrotron Radiation Facility (BSRF). A polarization analysis of the final state of the transmitted radiation from the Ni film is employed to determine the Faraday rotation at the edges. The MO effect becomes resonantly enhanced at the M 2,3 edges, and accordingly large values for the rotation angle β of 1.85 ± 0.19° for this ferromagnetic Ni film with thickness of 31 nm are measured. Without the magnetic field, the azimuthal angles do not shift; with parallel and antiparallel magnetic field the rotation angles shift in the opposite way and they are symmetrical. The uncertainty of Faraday rotation angles mainly comes from the data fitting and the state change of the beamline when the angles are measured

  4. Correspondence of Michael Faraday, v.5 1855-1860

    CERN Document Server

    Faraday, Michael

    2008-01-01

    This volume includes 70% of previously unpublished letters of Michael Farday spanning half of the 1850s and most of 1860. Topics include Faraday's work on regelation, the transmission of light through gold and his appointment by Emperor Napoleon III to be a Commander of the Legion of Honour.

  5. Health Preemption Behind Closed Doors: Trade Agreements and Fast-Track Authority

    Science.gov (United States)

    Crosbie, Eric; Gonzalez, Mariaelena

    2014-01-01

    Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies’ influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. “Fast-track authority,” in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests. PMID:25033124

  6. Measurements of fast deuterons from plasma accelerator by means of PM-355 track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Skladnik-Sadowska, E. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Malinowski, K., E-mail: k.malinowski@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Sadowski, M.J.; Czaus, K. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland)

    2009-10-15

    This paper reports on studies of fast ions (mostly deuterons) emitted from an RPI (Rod-Plasma-Injector) plasma accelerator. The first aim was the verification of applicability of PM-355 track detectors for dosimetry of lower-energy (<200 KeV) deuterons. The second aim was information about energy spectra of deuterons from RPI-IBIS device in different operational modes. Mass- and energy spectra of ions were investigated with a Thomson-analyzer and PM-355 detectors. On the recorded deuteron-parabolas we chose points, and from numbers of tracks we determined the deuteron energy distribution. In the slow-mode the energy distribution peak was observed at about 40 keV, while the maximum energy amounted to about 150 keV. Those measurements confirmed an influence of the initial gas-conditions on energy distributions of the deuteron streams. The results are of importance for plasma-physics and applications. Another result was the confirmation that PM-355 detectors might be used for accurate measurements of low-energy (<200 keV) deuterons.

  7. Compact all-fiber optical Faraday components using 65-wt%-terbium-doped fiber with a record Verdet constant of -32 rad/(Tm).

    Science.gov (United States)

    Sun, L; Jiang, S; Marciante, J R

    2010-06-07

    A compact all-fiber Faraday isolator and a Faraday mirror are demonstrated. At the core of each of these components is an all-fiber Faraday rotator made of a 4-cm-long, 65-wt%-terbium-doped silicate fiber. The effective Verdet constant of the terbium-doped fiber is measured to be -32 rad/(Tm), which is 27 x larger than that of silica fiber. This effective Verdet constant is the largest value measured to date in any fiber and is 83% of the Verdet constant of commercially available crystal used in bulk optics-based isolators. Combining the all-fiber Faraday rotator with fiber polarizers results in a fully fusion spliced all-fiber isolator whose isolation is measured to be 19 dB. Combining the all-fiber Faraday rotator with a fiber Bragg grating results in an all-fiber Faraday mirror that rotates the polarization state of the reflected light by 88 +/- 4 degrees .

  8. 'Fast-track' colonic surgery in Austria and Germany--results from the survey on patterns in current perioperative practice.

    Science.gov (United States)

    Hasenberg, T; Keese, M; Längle, F; Reibenwein, B; Schindler, K; Herold, A; Beck, G; Post, S; Jauch, K W; Spies, C; Schwenk, W; Shang, E

    2009-02-01

    'Fast-track' rehabilitation has been shown to accelerate recovery, reduce general morbidity and decrease hospital stay after elective colonic surgery. Despite this evidence, there is no information on the acceptance and utilization of these concepts among the entirety of Austrian and German surgeons. In 2006, a questionnaire concerning perioperative routines in elective, open colonic resection was sent to the chief surgeons of 1270 German and 120 Austrian surgical centres. The response rate was 63% in Austria (76 centres) and 30% in Germany (385 centres). Mechanical bowel preparation is used by the majority (Austria, 91%; Germany, 94%); the vertical incision is the standard method of approach to the abdomen in Austria (79%) and Germany (83%), nasogastric decompression tubes are rarely used, one-third of the questioned surgeons in both countries use intra-abdominal drains. Half of the surgical centres allow the intake of clear fluids on the day of surgery and one-fifth offer solid food on that day. Epidural analgesia is used in three-fourths of the institutions. Although there is an evident benefit of fast-track management, the survey shows that they are not yet widely used as a routine in Austria and Germany.

  9. Performance of the JT-60 ICRF antenna with an open type Faraday shield

    International Nuclear Information System (INIS)

    Fujii, T.; Saigusa, M.; Kimura, H.; Moriyama, S.; Annoh, K.; Kawano, Y.; Kobayashi, N.; Kubo, H.; Nishitani, T.; Ogawa, Y.; Shinozaki, S.; Terakado, M.

    1992-01-01

    Performance of the JT-60 ICRF antenna in second and third harmonic heating schemes (f=120, 131 MHz) over past four years of operation is presented. The antenna is mainly composed of phased 2x2 loops, an open type Faraday shield and a metallic casing, forming a plug-in type. The antenna is operated for wide plasma parameters: anti n e =1-7x10 19 m -3 , I P =1-2.8 MA and B T =2.2-4.8 T. The open type Faraday shield shows no deterioration for impurity production and heating efficiency up to the maximum injected power of 3.1 MW (the power density of 16 MW/m 2 ) except the following particular condition. Only for (0, 0) phasing and less than 30 mm of the distance between the outermost magnetic surface and the antenna guard limiter, the radiation loss increases abruptly from ΔP rad /P IC ∝0.3 to ΔP rad /P IC ∝4 in carbon limiter discharges when the injected power exceeds a threshold value of ∝0.5 MW. Strong titanium impurity release from the Faraday shield is observed in coincidence with the increase in the radiation loss. This suggests that strong ion sputtering is induced on the Faraday shield by RF sheaths. (orig.)

  10. Design of Faraday cup ion detectors built by thin film deposition

    Energy Technology Data Exchange (ETDEWEB)

    Szalkowski, G.A., E-mail: gszalkowski3@gatech.edu [Department of Nuclear Engineering, Georgia Institute of Technology, 770 State St., Atlanta, GA 30332 (United States); Darrow, D.S., E-mail: ddarrow@pppl.gov [Princeton Plasma Physics Laboratory, P. O. Box 451, Princeton, NJ 08543 (United States); Cecil, F.E., E-mail: fcecil@mines.edu [Department of Physics, Colorado School of Mines, Golden, CO 80401 (United States)

    2017-03-11

    Thin film Faraday cup detectors can provide measurements of fast ion loss from magnetically confined fusion plasmas. These multilayer detectors can resolve the energy distribution of the lost ions in addition to giving the total loss rate. Prior detectors were assembled from discrete foils and insulating sheets. Outlined here is a design methodology for creating detectors using thin film deposition that are suited to particular scientific goals. The intention is to use detectors created by this method on the Joint European Torus (JET) and the National Spherical Torus Experiment-Upgrade (NSTX-U). The detectors will consist of alternating layers of aluminum and silicon dioxide, with layer thicknesses chosen to isolate energies of interest. Thin film deposition offers the advantage of relatively simple and more mechanically robust construction compared to other methods, as well as allowing precise control of film thickness. Furthermore, this depositional fabrication technique places the layers in intimate thermal contact, providing for three-dimensional conduction and dissipation of the ion-produced heating in the layers, rather than the essentially two-dimensional heat conduction in the discrete foil stack implementation.

  11. Coarsening of Faraday Heaps: Experiment, Simulation, and Theory

    NARCIS (Netherlands)

    Gerner, van H.J.; Robledo, Caballero G.A.; Meer, van der D.; Weele, van der J.P.; Hoef, van der M.A.

    2009-01-01

    When a layer of granular material is vertically shaken, the surface spontaneously breaks up in a landscape of small Faraday heaps that merge into larger ones on an ever increasing time scale. This coarsening process is studied in a linear setup, for which the average life span of the transient state

  12. Faraday effect revisited: sum rules and convergence issues

    DEFF Research Database (Denmark)

    Cornean, Horia; Nenciu, Gheorghe

    2010-01-01

    This is the third paper of a series revisiting the Faraday effect. The question of the absolute convergence of the sums over the band indices entering the Verdet constant is considered. In general, sum rules and traces per unit volume play an important role in solid-state physics, and they give...

  13. Enhancement of magneto-optical Faraday effects and extraordinary optical transmission in a tri-layer structure with rectangular annular arrays.

    Science.gov (United States)

    Lei, Chengxin; Chen, Leyi; Tang, Zhixiong; Li, Daoyong; Cheng, Zhenzhi; Tang, Shaolong; Du, Youwei

    2016-02-15

    The properties of optics and magneto-optical Faraday effects in a metal-dielectric tri-layer structure with subwavelength rectangular annular arrays are investigated. It is noteworthy that we obtained the strongly enhanced Faraday rotation of the desired sign along with high transmittance by optimizing the parameters of the nanostructure in the visible spectral ranges. In this system, we obtained two extraordinary optical transmission (EOT) resonant peaks with enhanced Faraday rotations, whose signs are opposite, which may provide the possibility of designing multi-channel magneto-optical devices. Study results show that the maximum of the figure of merit (FOM) of the structure can be obtained between two EOT resonant peaks accompanied by an enhanced Faraday rotation. The positions of the maximum value of the FOM and resonant peaks of transmission along with a large Faraday rotation can be tailored by simply adjusting the geometric parameters of our models. These research findings are of great importance for future applications of magneto-optical devices.

  14. Wideband converter of a charge of particle beam incident on a Faraday cylinder into a number of pulses

    International Nuclear Information System (INIS)

    Shchagin, A.V.; Lysenko, V.F.

    1985-01-01

    An electric circuit of a beam positive charge-pulse converter during beam incidence on a Faraday cylinder (conversion of Faraday cylinder current into F frequency, where F=10 10 J, where J - is the Faraday cylinder current) is described. Conversion ratio is 10 10 pulses/KP (10 10 Hz/A). Input current change limits are 10 -10 -10 -4 A. Conversion error is |ΔF| -3 F +0.1 Hz). ''Dead'' time is absent. Input resistance of the converter is close to zero

  15. Non-destructive Faraday imaging of dynamically controlled ultracold atoms

    DEFF Research Database (Denmark)

    Gajdacz, Miroslav; Pedersen, Poul Lindholm; Mørch, Troels

    2013-01-01

    We describe an easily implementable method for non-destructive measurements of ultracold atomic clouds based on dark field imaging of spatially resolved Faraday rotation. The signal-to-noise ratio is analyzed theoretically and, in the absence of experimental imperfections, the sensitivity limit...

  16. Non-destructive Faraday imaging of dynamically controlled ultracold atoms

    Science.gov (United States)

    Gajdacz, Miroslav; Pedersen, Poul; Mørch, Troels; Hilliard, Andrew; Arlt, Jan; Sherson, Jacob

    2013-05-01

    We investigate non-destructive measurements of ultra-cold atomic clouds based on dark field imaging of spatially resolved Faraday rotation. In particular, we pursue applications to dynamically controlled ultracold atoms. The dependence of the Faraday signal on laser detuning, atomic density and temperature is characterized in a detailed comparison with theory. In particular the destructivity per measurement is extremely low and we illustrate this by imaging the same cloud up to 2000 times. The technique is applied to avoid the effect of shot-to-shot fluctuations in atom number calibration. Adding dynamic changes to system parameters, we demonstrate single-run vector magnetic field imaging and single-run spatial imaging of the system's dynamic behavior. The method can be implemented particularly easily in standard imaging systems by the insertion of an extra polarizing beam splitter. These results are steps towards quantum state engineering using feedback control of ultracold atoms.

  17. Fast algorithm of track detection

    International Nuclear Information System (INIS)

    Nehrguj, B.

    1980-01-01

    A fast algorithm of variable-slope histograms is proposed, which allows a considerable reduction of computer memory size and is quite simple to carry out. Corresponding FORTRAN subprograms given a triple speed gain have been included in spiral reader data handling software

  18. Theoretical and numerical evaluation of polarimeter using counter-circularly-polarized-probing-laser under the coupling between Faraday and Cotton-Mouton effect.

    Science.gov (United States)

    Imazawa, Ryota; Kawano, Yasunori; Itami, Kiyoshi

    2016-04-01

    This study evaluated an effect of an coupling between the Faraday and Cotton-Mouton effect to a measurement signal of the Dodel-Kunz method which uses counter-circular-polarized probing-laser for measuring the Faraday effect. When the coupling is small (the Faraday effect is dominant and the characteristic eigenmodes are approximately circularly polarized), the measurement signal can be algebraically expressed and it is shown that the finite effect of the coupling is still significant. When the Faraday effect is not dominant, a numerical calculation is necessary. The numerical calculation under an ITER-like condition (Bt = 5.3 T, Ip = 15 MA, a = 2 m, ne = 10(20) m(-3) and λ = 119 μm) showed that difference between the pure Faraday rotation and the measurement signal of the Dodel-Kunz method was an order of one degree, which exceeds allowable error of ITER poloidal polarimeter. In conclusion, similar to other polarimeter techniques, the Dodel-Kunz method is not free from the coupling between the Faraday and Cotton-Mouton effect.

  19. Post-discharge symptoms following fast-track colonic cancer surgery: a phenomenological hermeneutic study

    DEFF Research Database (Denmark)

    Krogsgaard, Marianne; Dreyer, Pia; Egerod, Ingrid

    2014-01-01

    OBJECTIVE: To obtain knowledge of patients' experiences of postoperative symptoms during the initial two weeks following fast-track colonic cancer surgery. METHOD: Semi-structured in-depth interviews with seven colonic cancer patients two weeks post hospital discharge. Analysis was performed using...... a phenomenological hermeneutical approach. RESULTS: During the first two weeks after discharge the patients experienced unfamiliar symptoms that affected their everyday lives. Despite distressing symptoms, they applied a "wait-and-see" strategy, and only reacted when symptoms became intolerable. The patients failed...... to shorter hospitalisation and improved physical performance, post-colonic surgery patients experience various symptoms after discharge. Healthcare professionals need to address symptoms that might have immediate and long-term consequences on patients' everyday life. Follow-up studies are encouraged...

  20. Faraday Rotation for SMOS Retrievals of Ocean Salinity and Soil Moisture

    Science.gov (United States)

    El-Nimri, Salem; Le Vine, David M.

    2016-01-01

    Faraday rotation is a change in polarization as radiation propagates from the surface through the ionosphere to the sensor. At L-band (1.4 GHz) this change can be significant and can be important for the remote sensing of soil moisture and ocean salinity from space. Consequently, modern L-band radiometers (SMOS, Aquarius and SMOS) are polarimetric to measure Faraday rotation in situ so that a correction can be made. This is done using the ratio of the third and second Stokes parameters. In the case of SMOS this procedure has produced very noisy estimates. An alternate procedure is reported here in which the total electron content is estimated and averaged to reduce noise.