  1. High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.

    Science.gov (United States)

    El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin

    2012-07-01

    Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.

  2. Introducing Bayesian thinking to high-throughput screening for false-negative rate estimation.

    Science.gov (United States)

    Wei, Xin; Gao, Lin; Zhang, Xiaolei; Qian, Hong; Rowan, Karen; Mark, David; Peng, Zhengwei; Huang, Kuo-Sen

    2013-10-01

    High-throughput screening (HTS) has been widely used to identify active compounds (hits) that bind to biological targets. Because of cost concerns, the comprehensive screening of millions of compounds is typically conducted without replication. Real hits that fail to exhibit measurable activity in the primary screen due to random experimental errors will be lost as false-negatives. Conceivably, the projected false-negative rate is a parameter that reflects screening quality. Furthermore, it can be used to guide the selection of optimal numbers of compounds for hit confirmation. Therefore, a method that predicts false-negative rates from the primary screening data is extremely valuable. In this article, we describe the implementation of a pilot screen on a representative fraction (1%) of the screening library in order to obtain information about assay variability as well as a preliminary hit activity distribution profile. Using this training data set, we then developed an algorithm based on Bayesian logic and Monte Carlo simulation to estimate the number of true active compounds and potential missed hits from the full library screen. We have applied this strategy to five screening projects. The results demonstrate that this method produces useful predictions on the numbers of false negatives.

  3. False-Negative Rate of Gram-Stain Microscopy for Diagnosis of Septic Arthritis: Suggestions for Improvement

    Directory of Open Access Journals (Sweden)

    Paul Stirling

    2014-01-01

    Full Text Available We quantify the false-negative diagnostic rate of septic arthritis using Gram-stain microscopy of synovial fluid and compare this to values reported in the peer-reviewed literature. We propose a method of improving the diagnostic value of Gram-stain microscopy using Lithium Heparin containers that prevent synovial fluid coagulation. Retrospective study of the Manchester Royal Infirmary microbiology database of patients undergoing synovial fluid Gram-stain and culture between December 2003 and March 2012 was undertaken. The initial cohort of 1896 synovial fluid analyses for suspected septic arthritis was reduced to 143 after exclusion criteria were applied. Analysis of our Gram-stain microscopy yielded 111 false-negative results from a cohort size of 143 positive synovial fluid cultures, giving a false-negative rate of 78%. We report a false-negative rate of Gram-stain microscopy for septic arthritis of 78%. Clinicians should therefore avoid the investigation until a statistically significant data set confirms its efficacy. The investigation's value could be improved by using Lithium Heparin containers to collect homogenous synovial fluid samples. Ongoing research aims to establish how much this could reduce the false-negative rate.

  4. Mobile natural gas leak surveys indicate that two utilities have high false negative rates

    Science.gov (United States)

    von Fischer, J. C.; Brewer, P. E.; Chamberlain, S.; Gaylord, A.; von Fischer, J.

    2016-12-01

    In the distribution systems that carry natural gas to consumers, leaks need to be discovered for safety reasons and to reduce greenhouse gas emissions. However, few utilities have adopted newer laser-based technologies that have greater sensitivity and precision, and instead rely on "industry standard" equipment that is far less sensitive. In partnership with the Environmental Defense Fund and Google, we mapped natural gas leaks in the domains of two anonymous utilities (Utility "A" and "B") using high sensitivity Picarro methane analyzers in Google Street View Cars. Surprisingly, when we shared these results with utilities, their survey crews were unable to find most of the leaks that our survey indicated (84% in A and 80% in B). To investigate this phenomenon, our team visited a subset of the leaks in each utility domain (n=32 in A and n=30 in B), and worked alongside utility surveyors to search the leak indication area, using a Los Gatos Research ultraportable methane analyzer to pinpoint leak locations. We found evidence of natural gas leaks at 69% and 68% of the locations in Utilities A and B respectively where survey crews had found nothing. We describe this as a "false negative" rate for the utility because the utility survey falsely indicated that there was no leak at these locations. Of these false negatives, 7% (n=2 of 32 in A, n=2 of 30 in B) were determined to be Grade 1 leaks requiring immediate repair due to high safety risk. Instrument sensitivity appears to explain some of the false negative rates. In particular, use of some industry standard equipment appears to have created a false sense of confidence among utility surveyors that leaks were not present. However, there was also evidence of communication failures and that surveyors did not use optimal approaches in their search. Based on these findings, we suggest that: 1) mobile deployment of high-precision methane analyzers can help find more natural gas leaks, and 2) use of some hand-held survey

  5. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  6. False Positive and False Negative Effects on Network Attacks

    Science.gov (United States)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  7. Improving Universal Suicide Prevention Screening in Primary Care by Reducing False Negatives

    Science.gov (United States)

    2017-09-01

    craig.bryan@utah.edu 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) University of Utah 8. PERFORMING ORGANIZATION REPORT...screening methods by reducing false negative rates; and (c) to systematically quantify false negative rates across various patient subgroups (e.g., gender ...c) to systematically quantify false negative rates across various patient subgroups (e.g., gender , race, age, deployment history, etc.) to identify

  8. Personnel selection and emotional stability certification: establishing a false negative error rate when clinical interviews

    International Nuclear Information System (INIS)

    Berghausen, P.E. Jr.

    1987-01-01

    The security plans of nuclear plants generally require that all personnel who are to have unescorted access to protected areas or vital islands be screened for emotional instability. Screening typically consists of first administering the MMPI and then conducting a clinical interview. Interviews-by-exception protocols provide for only those employees to be interviewed who have some indications of psychopathology in their MMPI results. A problem arises when the indications are not readily apparent: False negatives are likely to occur, resulting in employees being erroneously granted unescorted access. The present paper describes the development of a predictive equation which permits accurate identification, via analysis of MMPI results, of those employees who are most in need of being interviewed. The predictive equation also permits knowing probably maximum false negative error rates when a given percentage of employees is interviewed

  9. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    Science.gov (United States)

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  10. A critical reappraisal of false negative sentinel lymph node biopsy in melanoma

    International Nuclear Information System (INIS)

    Manca, G.; Mazzarri, S.; Boni, G.; Chiacchio, S.; Tredici, M.; Duce, V.; Tardelli, E.; Volterrani, D.; Mariani, G.; Romanini, A.; Rubello, D.

    2014-01-01

    Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of “actual” positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the

  11. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  12. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  13. Analysis of false positive and false negative cytological diagnosis of breast lesions

    International Nuclear Information System (INIS)

    Jamal, Awtif A.; Mansoor, I.

    2001-01-01

    To study the reasons for interpretive errors in false negative and false positive diagnosis of breast carcinoma on fine needle aspiration cytology material. We reviewed only those cases in which cytohistological discrepancies were found, where the cytologic material was abnormal and to some extent misinterpreted or both. There was only one false negative case (false negative fraction 0.32%) proved histologically as ductal carcinoma and four false positive cases (false positive fraction 1.2%); 2 fibroadenoma; 1 fibrocystic disease; and 1 stromal fibrosis. Smears of the two false positive fibroadenoma cases showed very high cellularity, overcrowded clusters and frequent stripped nuclei. The fibrocystic case showed tight clusters of apocrine cells and sheets of loosely aggregated macrophages that were over interpreted. Smears of the false negative ductal carcinoma was hypocellular overall, and the cells showed minimal nuclear pleomorphism. Overcrowded clusters and hypercellular smears should be carefully assessed for uniformity of cells and detailed nuclear and cytomorphological features. If the full-blown malignant cytomorphological changes are not visible, a diagnosis of suspicious or inconclusive should be made and frozen section recommended before surgery. Hypocellularity and relatively nuclear monomorphism are the reasons for failure to diagnose malignant breast lesions. Careful attention should be paid to extreme nuclear monomorphism and absence of naked bipolar cells. A cytologically atypical or suspicious diagnosis together with positive radiological and clinical findings should suggest a diagnosis of malignancy. (author)

  14. Underpowered samples, false negatives, and unconscious learning.

    Science.gov (United States)

    Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R

    2016-02-01

    The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.

  15. False positive and false negative FDG-PET scans in various thoracic diseases

    International Nuclear Information System (INIS)

    Chang, Jung Min; Lee, Hyun Ju; Goo, Jin Mo; Lee, Ho Young; Lee, Jong Jin; Chung, June Key; Im, Jung Gi

    2006-01-01

    Fluorodeoxygucose (FDG)-positron emission tomography (PET) is being used more and more to differentiate benign form malignant focal lesions and it has been shown to be more efficacious than conventional chest computed tomography (CT). However, FDG is not a cancer-specific agent, and false positive findings in benign diseases have been reported. Infectious diseases (mycobacterial, fungal, bacterial infection), sarcoidosis, radiation pneumonitis and post-operative surgical conditions have shown intense uptake on PET scan. On the other hand, tumors with low glycolytic activity such as adenomas, bronchioloalveolar carcinomas, carcinoid tumors, low grade lymphomas and small sized tumors have revealed false negative findings on PET scan, Furthermore, in diseases located near the physiologic uptake sites (heart, bladder, kidney, and liver), FDG-PET should be complemented with other imaging modalities to confirm results and to minimize false negative findings. Familiarity with these false positive and negative findings will help radiologists interpret PET scans more accurately and also will help to determine the significance of the findings. In this review, we illustrate false positive and negative findings of PET scan in a variety of diseases

  16. Impact of age on the false negative rate of human papillomavirus DNA test in patients with atypical squamous cells of undetermined significance.

    Science.gov (United States)

    Won, Kyu-Hee; Lee, Jae Yeon; Cho, Hye-Yon; Suh, Dong Hoon; No, Jae Hong; Kim, Yong-Beom

    2015-03-01

    Human papillomavirus (HPV) test was incorporated into the triage of lesser abnormal cervical cytologies: atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesion (LSIL). This study aimed to evaluate the impact of age on the efficacy of HPV testing in patients with lesser abnormal cervical cytologies. A total of 439 patients with ASCUS or LSIL were included. The association between age groups and the diagnostic performances of HPV test for high-grade cervical intraepithelial neoplasia (CIN2+) was evaluated. Median age was 44 years (range, 17 to 75 years). ASCUS was more frequently observed in older patients while LSIL was more common in younger patients (P=0.002). CIN2+ was found in 11.3% (32/284) of the ASCUS patients and 12.9% (20/155) of patients with LSIL. Older patients with ASCUS showed lower HPV infection rates (P=0.025), but not LSIL (P=0.114). However, the prevalence of CIN2+ was similar between the age groups with ASCUS or LSIL. In patients with ASCUS, the false negative rate of HPV test for CIN2+ was 6.2%. The false negative rate of the HPV test became higher with increasing of the age after the age of 50 (P=0.034). Our findings suggest that false negative rate of the HPV test for CIN2+ in ASCUS patients older than 50 years might become higher with increasing of the age. Negative HPV results in patients of the age >50 years with ASCUS should be carefully interpreted.

  17. False-negative diffusion-weighted imaging findings in acute stroke

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Yuasa, Naoki; Otomo, Takashi; Shiramizu, Hideki; Matsuda, Hiroshi; Kitagawa, Yasuhisa; Takagi, Shigeharu

    2006-01-01

    The utility of DWI (diffusion-weighted imaging) has been established in acute ischemic stroke. However, some patients with acute stroke show no abnormal signals on DWI, despite the presence of infarction (false-negative DWI). We analyzed the relationship between false-negative DWI and the clinical manifestations of acute ischemic stroke in 151 DWI-positive (89%) and 19 false-negative DWI (11%) patients. We performed MRI within 24 hours after onset at our hospital. Non-specific clinical manifestations, including vertigo and nausea, were frequently observed in false-negative DWI patients. As regards the vascular territory, false-negative DWI was noted in 15.3% of 59 patients with infarctions within the territory of the vertebrobasilar artery. Concerning the duration from onset to initial imaging, 73.7% of the patients with false-negative DWI findings underwent MRI examination within 6 hours after onset. Of the patients with false-negative DWI, 84.2% had lacunar infarction (χ 2 =16.4, P<0.001). In conclusion, false negative DWI is more frequently observed in lacunar infarction than in atherothrombotic infarction or cardiogenic embolism. It is important to examine carefully the neurological changes occurring in patients who present with acute stroke, but have negative DWI findings. (author)

  18. How does negative emotion cause false memories?

    Science.gov (United States)

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  19. The problem of false positives and false negatives in violent video game experiments.

    Science.gov (United States)

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  1. Do negative screening test results cause false reassurance? A systematic review.

    Science.gov (United States)

    Cooper, Grace C; Harvie, Michelle N; French, David P

    2017-11-01

    It has been suggested that receiving a negative screening test result may cause false reassurance or have a 'certificate of health effect'. False reassurance in those receiving a negative screening test result may result in them wrongly believing themselves to be at lower risk of the disease, and consequently less likely to engage in health-related behaviours that would lower their risk. The present systematic review aimed to identify the evidence regarding false reassurance effects due to negative screening test results in adults (over 18 years) screened for the presence of a disease or its precursors, where disease or precursors are linked to lifestyle behaviours. MEDLINE and PsycINFO were searched for trials that compared a group who had received negative screening results to an unscreened control group. The following outcomes were considered as markers of false reassurance: perceived risk of disease; anxiety and worry about disease; health-related behaviours or intention to change health-related behaviours (i.e., smoking, diet, physical activity, and alcohol consumption); self-rated health status. Nine unique studies were identified, reporting 55 measures in relation to the outcomes considered. Outcomes were measured at various time points from immediately following screening to up to 11 years after screening. Despite considerable variation in outcome measures used and timing of measurements, effect sizes for comparisons between participants who received negative screening test results and control participants were typically small with few statistically significant differences. There was evidence of high risk of bias, and measures of behaviours employed were often not valid. The limited evidence base provided little evidence of false reassurance following a negative screening test results on any of four outcomes examined. False reassurance should not be considered a significant harm of screening, but further research is warranted. Statement of contribution

  2. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    Science.gov (United States)

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  4. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  5. "Hook-like effect" causes false-negative point-of-care urine pregnancy testing in emergency patients.

    Science.gov (United States)

    Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F

    2013-01-01

    Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  7. False negative rate of syndesmotic injury in pronation-external rotation stage IV ankle fractures

    Directory of Open Access Journals (Sweden)

    Kwang-Soon Song

    2013-01-01

    Full Text Available Background: To investigate false negative rate in the diagnosis of diastasis on initial static anteroposterior radiograph and reliability of intraoperative external rotational stress test for detection of concealed disruption of syndesmosis in pronation external rotation (PER stage IV (Lauge-Hansen ankle fractures. Materials and Methods: We prospectively studied 34 PER stage IV ankle fractures between September 2001 and September 2008. Twenty (59% patients show syndesmotic injury on initial anteroposterior radiographs. We performed an intraoperative external rotation stress test in other 14 patients with suspicious PER stage IV ankle fractures, which showed no defined syndesmotic injury on anteroposterior radiographs inspite of a medial malleolar fracture, an oblique fibular fracture above the syndesmosis and fracture of the posterior tubercle of the tibia. Results: All 14 fractures showed different degrees of tibiofibular clear space (TFCS and tibiofibular overlapping (TFO on the external rotation stress test radiograph compared to the initial plain anteroposterior radiograph. It is important to understand the fracture pattern characterstic of PER stage IV ankle fractures even though it appears normal on anteroposterior radiographs, it is to be confirmed for the concealed syndesmotic injury through a routine intraoperative external rotational stress radiograph.

  8. Experimental Design for a Macrofoam-Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-05

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam-swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (culture and polymerase chain reaction) will be used. Only one previous study has investigated how the false negative rate depends on test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gaps in the available information on the performance of macrofoam-swab sampling at low concentrations.

  9. Perils of intraoperative neurophysiological monitoring: analysis of "false-negative" results in spine surgeries.

    Science.gov (United States)

    Tamkus, Arvydas A; Rice, Kent S; McCaffrey, Michael T

    2018-02-01

    Although some authors have published case reports describing false negatives in intraoperative neurophysiological monitoring (IONM), a systematic review of causes of false-negative IONM results is lacking. The objective of this study was to analyze false-negative IONM findings in spine surgery. This is a retrospective cohort analysis. A cohort of 109 patients with new postoperative neurologic deficits was analyzed for possible false-negative IONM reporting. The causes of false-negative IONM reporting were determined. From a cohort of 62,038 monitored spine surgeries, 109 consecutive patients with new postoperative neurologic deficits were reviewed for IONM alarms. Intraoperative neurophysiological monitoring alarms occurred in 87 of 109 surgeries. Nineteen patients with new postoperative neurologic deficits did not have an IONM alarm and surgeons were not warned. In addition, three patients had no interpretable IONM baseline data and no alarms were possible for the duration of the surgery. Therefore, 22 patients were included in the study. The absence of IONM alarms during these 22 surgeries had different origins: "true" false negatives where no waveform changes meeting the alarm criteria occurred despite the appropriate IONM (7); a postoperative development of a deficit (6); failure to monitor the pathway, which became injured (5); the absence of interpretable IONM baseline data which precluded any alarm (3); and technical IONM application issues (1). Overall, the rate of IONM method failing to predict the patient's outcome was very low (0.04%, 22/62,038). Minimizing false negatives requires the application of a proper IONM technique with the limitations of each modality considered in their selection and interpretation. Multimodality IONM provides the most inclusive information, and although it might be impractical to monitor every neural structure that can be at risk, a thorough preoperative consideration of available IONM modalities is important. Delayed

  10. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  11. False-negative dipyridamole-thallium-201 myocardial imaging after caffeine infusion

    International Nuclear Information System (INIS)

    Smits, P.; Corstens, F.H.; Aengevaeren, W.R.; Wackers, F.J.; Thien, T.

    1991-01-01

    The vasodilator effect of intravenously administered dipyridamole may be caused by an increase in endogenous plasma adenosine levels. The authors evaluated the effect of caffeine, an adenosine receptor antagonist, on the diagnostic results of dipyridamole-201Tl myocardial imaging in eight patients with coronary artery disease. Caffeine infusion significantly attenuated the dipyridamole-induced fall in blood pressure and the accompanied increase in heart rate. The infusion of dipyridamole alone resulted in chest pain and ST-segment depressions on the electrocardiogram in four patients, whereas none of these problems occurred when the tests were repeated after caffeine. In six of eight patients, caffeine was responsible for false-negative dipyridamole-201Tl tests. Semiquantitive scores of the dipyridamole-induced 201Tl perfusion defects were decreased by caffeine from 9.0 ± 0.9 to 2.0 ± 1.1 points (p less than 0.05). Computerized analysis revealed a caffeine-mediated reduction in the percent reversibility of the images from 46% ± 16% to 6% ± 10% (p less than 0.05). They conclude that the use of caffeinated products prior to dipyridamole-201Tl testing may be responsible for false-negative findings

  12. False-negative dipyridamole-thallium-201 myocardial imaging after caffeine infusion

    Energy Technology Data Exchange (ETDEWEB)

    Smits, P.; Corstens, F.H.; Aengevaeren, W.R.; Wackers, F.J.; Thien, T. (University Hospital Nijmegen (Netherlands))

    1991-08-01

    The vasodilator effect of intravenously administered dipyridamole may be caused by an increase in endogenous plasma adenosine levels. The authors evaluated the effect of caffeine, an adenosine receptor antagonist, on the diagnostic results of dipyridamole-201Tl myocardial imaging in eight patients with coronary artery disease. Caffeine infusion significantly attenuated the dipyridamole-induced fall in blood pressure and the accompanied increase in heart rate. The infusion of dipyridamole alone resulted in chest pain and ST-segment depressions on the electrocardiogram in four patients, whereas none of these problems occurred when the tests were repeated after caffeine. In six of eight patients, caffeine was responsible for false-negative dipyridamole-201Tl tests. Semiquantitive scores of the dipyridamole-induced 201Tl perfusion defects were decreased by caffeine from 9.0 {plus minus} 0.9 to 2.0 {plus minus} 1.1 points (p less than 0.05). Computerized analysis revealed a caffeine-mediated reduction in the percent reversibility of the images from 46% {plus minus} 16% to 6% {plus minus} 10% (p less than 0.05). They conclude that the use of caffeinated products prior to dipyridamole-201Tl testing may be responsible for false-negative findings.

  13. Memory for media: investigation of false memories for negatively and positively charged public events.

    Science.gov (United States)

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  14. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.

    2013-11-04

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.\\'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  15. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2013-01-01

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  16. Resolving the false-negative issues of the nonpolar organic amendment in whole-sediment toxicity identification evaluations.

    Science.gov (United States)

    Mehler, W Tyler; Keough, Michael J; Pettigrove, Vincent

    2018-04-01

    Three common false-negative scenarios have been encountered with amendment addition in whole-sediment toxicity identification evaluations (TIEs): dilution of toxicity by amendment addition (i.e., not toxic enough), not enough amendment present to reduce toxicity (i.e., too toxic), and the amendment itself elicits a toxic response (i.e., secondary amendment effect). One such amendment in which all 3 types of false-negatives have been observed is with the nonpolar organic amendment (activated carbon or powdered coconut charcoal). The objective of the present study was to reduce the likelihood of encountering false-negatives with this amendment and to increase the value of the whole-sediment TIE bioassay. To do this, the present study evaluated the effects of various activated carbon additions to survival, growth, emergence, and mean development rate of Chironomus tepperi. Using this information, an alternative method for this amendment was developed which utilized a combination of multiple amendment addition ratios based on wet weight (1%, lower likelihood of the secondary amendment effect; 5%, higher reduction of contaminant) and nonconventional endpoints (emergence, mean development rate). This alternative method was then validated in the laboratory (using spiked sediments) and with contaminated field sediments. Using these multiple activated carbon ratios in combination with additional endpoints (namely, emergence) reduced the likelihood of all 3 types of false-negatives and provided a more sensitive evaluation of risk. Environ Toxicol Chem 2018;37:1219-1230. © 2017 SETAC. © 2017 SETAC.

  17. Experimental Design for a Macrofoam Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Hutchison, Janine R.

    2014-04-16

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (plating/counting and polymerase chain reaction) will be used. Only one previous study has investigated false negative as a function of affecting test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gaps in the available information on the performance of macrofoam swab sampling at low concentrations.

  18. Negative affect promotes encoding of and memory for details at the expense of the gist: affect, encoding, and false memories.

    Science.gov (United States)

    Storbeck, Justin

    2013-01-01

    I investigated whether negative affective states enhance encoding of and memory for item-specific information reducing false memories. Positive, negative, and neutral moods were induced, and participants then completed a Deese-Roediger-McDermott (DRM) false-memory task. List items were presented in unique spatial locations or unique fonts to serve as measures for item-specific encoding. The negative mood conditions had more accurate memories for item-specific information, and they also had fewer false memories. The final experiment used a manipulation that drew attention to distinctive information, which aided learning for DRM words, but also promoted item-specific encoding. For the condition that promoted item-specific encoding, false memories were reduced for positive and neutral mood conditions to a rate similar to that of the negative mood condition. These experiments demonstrated that negative affective cues promote item-specific processing reducing false memories. People in positive and negative moods encode events differently creating different memories for the same event.

  19. Sadder and less accurate? False memory for negative material in depression.

    Science.gov (United States)

    Joormann, Jutta; Teachman, Bethany A; Gotlib, Ian H

    2009-05-01

    Previous research has demonstrated that induced sad mood is associated with increased accuracy of recall in certain memory tasks; the effects of clinical depression, however, are likely to be quite different. The authors used the Deese-Roediger-McDermott paradigm to examine the impact of clinical depression on erroneous recall of neutral and/or emotional stimuli. Specifically, they presented Deese-Roediger-McDermott lists that were highly associated with negative, neutral, or positive lures and compared participants diagnosed with major depressive disorder and nondepressed control participants on the accuracy of their recall of presented material and their false recall of never-presented lures. Compared with control participants, major depressive disorder participants recalled fewer words that had been previously presented but were more likely to falsely recall negative lures; there were no differences between major depressive disorder and control participants in false recall of positive or neutral lures. These findings indicate that depression is associated with false memories of negative material.

  20. Magnetic resonance imaging of lumbar spine disc diseases. Frequency of false negatives

    International Nuclear Information System (INIS)

    Berthelot, J.M.; Maugars, Y.; Delecrin, Y.; Caillon, F.; Prost, A.

    1995-01-01

    Magnetic resonance imaging (MRI) has had an impressive impact on evaluation of degenerative diseases of the spine. Nevertheless, false negatives can occur on images involving lumbar discs. Degenerative disc diseases documented on discography and/or pathology examination of the discs can go unrecognized. Likewise sensitivity for the detection of protruding disc hernias is not totally satisfactory (20% false negatives). Finally, a magnetic resonance image visualizing displacement of the disc is not specific (10 to 15% false positives); images showing protrusion or hernia can be seen in 30% of asymptomatic patients. Although MRI gives slightly more information than other imaging techniques, false images do exist. Moreover, the usefulness of MRI to demonstrate disc disease in case of a negative CT-scan remains to be demonstrated. (authors). 26 refs

  1. The false sero-negativity of brucella standard agglutination test: Prozone phenomenon

    Directory of Open Access Journals (Sweden)

    İrfan Binici

    2011-12-01

    Full Text Available Objectives: We aimed to assess prozone phenomenon that is quite rare and causes false negativity in serological diagnosisof brucellosis with standard dilution titers.Materials and methods: In this study the tests of four cases that have false negative serological results were evaluated.Blood cultures were obtained from all cases while cerebrospinal fluid cultures were studied in the two cases. Standardagglutination test (SAT and Coombs test were performed to all patients.Results: SAT and Coombs test was negative in titers up to 1/640 in all cases. The SAT and Coombs tests in cerebrospinalfluid (CSF of the two cases with neurobrucellosis diagnosis were negative, as well. Since the clinical and laboratoryfindings suggested the brucellosis, the serums were restudied by diluting up to 1/10240 titer and we saw that the first3 cases became positive at a titer of 1/1280. The fourth case remained negative and therefore, we applied high dilutionCoombs test. This time the test gave a positive result at 1/10240 titer beginning from 1/2560 titer. B.melitensis wasisolated from two cases.Conclusion: SAT and Coombs’ test must be diluted to titers 1/2560 or more in order to exclude false sero-negativity incases with clinical and laboratory findings suggesting brucellosis. J Microbiol Infect Dis 2011; 1(3:110-113

  2. Demographic predictors of false negative self-reported tobacco use status in an insurance applicant population.

    Science.gov (United States)

    Palmier, James; Lanzrath, Brian; Dixon, Ammon; Idowu, Oluseun

    2014-01-01

    To identify and quantify demographic correlates of false-negative self-reporting of tobacco use in life insurance applicants. Several studies have assessed the sensitivity of self-reporting for tobacco use in various populations, but statistical examination of the causes of misreporting has been rarer. The very large (488,000 confirmed tobacco users) sample size, US-wide geographic scope, and unique incentive structure of the life insurance application process permit more robust and insurance industry-specific results in this study. Approximately 6.2 million life insurance applicants for whom both tobacco-use interview questions and a confirmatory urine cotinine test were completed between 1999 and 2012 were evaluated for consistency between self-reported and laboratory-confirmed tobacco-use status. The data set was subjected to logistic regression to identify predictors of false negative self-reports (FNSR). False-negative self-reporting was found to be strongly associated with male gender, applicant ages of less than 30 or greater than 60, and low cotinine positivity rates in the applicant's state of residence. Policy face value was also moderately predictive, values above $500,000 associated with moderately higher FNSR. The findings imply that FNSR in life insurance applicants may be the result of complex interactions among financial incentives, geography and presumptive peer groups, and gender.

  3. New contributions to the prevalence of eating disorders in Spanish adolescents: detection of false negatives.

    Science.gov (United States)

    Rodríguez-Cano, Teresa; Beato-Fernández, Luis; Belmonte-Llario, Antonia

    2005-03-01

    Although the epidemiology of Eating Disorders (ED) has been highly developed in Spain, further research considering false negatives and also the prevalence of these disorders in males are needed. They were the aims of the present study. One thousand and seventy six adolescents (500 males and 576 females) participated in a two-stage survey. At the age of 13, apart from exploring numerous clinical and psychosocial variables, they were assessed by means of self-administered screening instruments, the eating attitude test (EAT), bulimic investigatory test Edinburgh (BITE), and body shape questionnaire (BSQ). The subjects were interviewed again 2 years later. Afterwards, 159 probable cases and 150 controls were interviewed by means of the structured interview SCAN. Prevalence of ED in adolescents was 3.71% (95% CI 2.58-4.83; 6.4% of females, 0.6% of males): anorexia nervosa 0.1%, bulimia nervosa 0.75%, eating disorder not otherwise specified (EDNOS) = 2.88%. The rate of false negative was 2.6% of the control group and most of them were EDNOS. The prevalence of ED obtained in our study, higher than others found in previous Spanish research, and a relatively high percentage of false negatives both indicate that up to now the prevalence of ED in Spanish adolescents could be underestimated.

  4. When are false-positive and false-negative 18F'FDG PET scans really false?

    International Nuclear Information System (INIS)

    Binns, D.S.; Hicks, R.J.; Fawcett, M.E.

    1999-01-01

    Full text: A 61-year-old male presented with locally advanced squamous cell carcinoma of the base of tongue. In the absence of wider metastatic disease on conventional staging, he was enrolled in a phase I, dose escalation chemoradiotherapy trial. In this study, therapeutic response to radiotherapy combined with cisplatin and a chemotherapeutic agent which specifically targets hypoxic cells (tirapazamine) was evaluated with serial 18 F-FDG PET scans. Baseline 18 F-FDG PET confirmed locally advanced disease, although a previously undetected lower cervical lymph node was identified and included in the radiotherapy portal. Whole-body PET revealed a small metabolically active area adjacent to the right hemidiaphragm. Respiratory gated, high-resolution helical CT failed to find structural evidence of disease and, as a result, the patient was enrolled in the 7 week therapy regime on the assumption that the PET finding was a false-positive result. Repeat 18 F-FDG PET scans at the middle, end and 12 weeks post-treatment showed excellent therapeutic response in the head and neck which was discordant with clinical and CT findings, and resolution of the metabolically active chest lesion. Despite the negative PET scan, persistent clinical and CT evidence of a residual tumour mass suggested a false-negative result and resulted in a neck lymph node dissection. This showed no evidence of malignant cells. Five months following treatment, the patient presented with pleural effusion at the base on the right lung. Subsequent CT scanning showed a small pleural lesion at the site of initial 18 F-FDG uptake. Biopsy confirmed metastatic disease. The apparent transient resolution of 18 F-FDG uptake in the pleural lesion with treatment presumably reflected a combination of reduced metabolic activity and size due to the partial, but not complete, cytotoxic effects of cisplatin. In conclusion, this case emphasizes the importance of pathological review and clinical follow-up in reconciling

  5. The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.

    Science.gov (United States)

    Di, Li; Li, Yan

    2018-02-01

    T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.

  6. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Directory of Open Access Journals (Sweden)

    Yamaguchi Rin

    2012-05-01

    Full Text Available Abstract Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases, to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6% cases were benign, including mastopathy (fibrocystic disease in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9% cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC being significantly more frequent (49.5% than papillotubular growing type (Papi-tub (P P = 0.0001 and ductal carcinoma in situ (DCIS (P = 0.0001. Among 458 indeterminate cases, 54/139 (38.8% were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0% and 73/139 (52.5% were malignant, with SIDC being the most frequent malignant tumor (37.0%. Among 52 false-negative cases, SIDC was significantly more frequent (42.3% than DCIS (P = 0.0049 and Papi-tub (P = 0.001. There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for

  7. Exchange rate behavior with negative interest rates: Some early negative observations

    OpenAIRE

    Hameed, Allaudeen S.; Rose, Andrew

    2017-01-01

    This paper examines exchange rate behavior during the recent period with negative nominal interest rates. We use a daily panel of data on 61 currencies from January 2010 through May 2016, during which five economies - Denmark, the European Economic and Monetary Union, Japan, Sweden, and Switzerland - experienced negative nominal interest rates. We examine both effective exchange rates and bilateral rates; the latter typically measured against the Swiss franc since Switzerland has had the long...

  8. Limited agreement of independent RNAi screens for virus-required host genes owes more to false-negative than false-positive factors.

    Directory of Open Access Journals (Sweden)

    Linhui Hao

    Full Text Available Systematic, genome-wide RNA interference (RNAi analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%. However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis.

  9. Does video-assisted mediastinoscopy offer lower false-negative rates for subcarinal lymph nodes compared with standard cervical mediastinoscopy?

    Science.gov (United States)

    Citak, Necati; Buyukkale, Songul; Kok, Abdulaziz; Celikten, Alper; Metin, Muzaffer; Sayar, Adnan; Gurses, Atilla

    2014-10-01

    Theoretically, video-assisted mediastinoscopy (VAM) offers improved staging of subcarinal lymph nodes (LNs) compared with standard cervical mediastinoscopy (SCM). Materials and Between 2006 and 2011, 553 patients (SCM, n = 293; VAM, n = 260) with non-small cell lung carcinoma who underwent mediastinoscopy were investigated. Mediastinoscopy was performed only in select patients based on computed tomography (CT) or positron emission tomography CT scans in our center. The mean number of LNs and stations sampled per case was significantly higher with VAM (n = 7.65 ± 1.68 and n = 4.22 ± 0.83) than with SCM (n = 6.91 ± 1.65 and 3.92 ± 86.4; p < 0.001). The percentage of patients sampled in station 7 was significantly higher with VAM (98.8%) than with SCM (93.8%; p = 0.002). Mediastinal LN metastasis was observed in 114 patients by mediastinoscopy. The remaining 439 patients (203 patients in VAM and 236 in SCM) underwent thoracotomy and systematic mediastinal lymphadenectomy (SML). SML showed mediastinal nodal disease in 23 patients (false-negative [FN] rate, 5.2%). The FN rate was higher with SCM (n = 14, 5.9%) than with VAM (n = 9, 4.4%), although this difference was not statistically significant (p = 0.490). Station 7 was the most predominant station for FN results (n = 15). The FN rate of station 7 was found to be higher with SCM (n = 9, 3.8%) than with the VAM group (n = 6, 2.9%; p = 0.623). FN were more common in mediastinoscopy of subcarinal LNs. VAM allows higher rates of sampling of mediastinal LN stations and station 7, although it did not improve staging of subcarinal LNs. Georg Thieme Verlag KG Stuttgart · New York.

  10. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  11. Facebook False Self-Presentation Behaviors and Negative Mental Health.

    Science.gov (United States)

    Wright, Elizabeth J; White, Katherine M; Obst, Patricia L

    2018-01-01

    As research examining what constitutes Facebook false self-presentation is lacking, the aim of this study was to develop a preliminary inventory of Facebook false self-presentation behaviors, as well as identify predictors and possible outcomes. Participants (N = 211) completed questions regarding frequency of engagement in Facebook false self-presentation behaviors, as well as self-esteem, social influences, motivation strategies, well-being, depression, anxiety, and stress. Results indicated the presence of two distinct false self-presentation behaviors: lying (e.g., untruthful status updates, profile creation) and liking behaviors (e.g., liking posts dishonestly), each associated with different predictors and outcomes. Results indicated that moral norms significantly predicted lying behaviors; and age, self-esteem, group norms, and moral norms significantly predicted liking behaviors. Unexpectedly, liking behaviors were associated with depression, anxiety, and stress, whereas lying behaviors were related to anxiety only. Findings highlight associations between online self-presentation strategies, in particular liking behaviors, on Facebook and possible offline negative mental health.

  12. Exclusively breastfed infants at risk for false negative double blind placebo controlled milk challenge

    NARCIS (Netherlands)

    Petrus, N. C. M.; Kole, E. A.; Schoemaker, A. A.; van Aalderen, W. M. C.; Sprikkelman, A. B.

    2014-01-01

    The double blind placebo controlled food challenge (DBPCFC) is the gold standard for diagnosing cow's milk allergy (CMA). However, false-negative DBPCFC have been reported. We present 2 cases with a false negative DBPCFC in exclusively breastfed infants suspected of CMA. These cases highlight the

  13. Introducing False EUR and False EUR exchange rates

    Science.gov (United States)

    Ausloos, M.; Ivanova, K.

    2000-10-01

    The Euro ( EUR) is a new currency introduced by the European Community. Its exchange rate is very puzzling. We have invented a false Euro ( FEUR) dating back to 1993 and have derived the exchange rates of the FEUR with respect to currencies not belonging to the EUR, i.e., DKK, CHF, JPY and USD. This allows us to search for correlations between the fluctuations preexisting to the introduction of EUR and present ones in such financial data. The detrended fluctuation analysis ( DFA) statistical method is used. This leads to assume a power-law behavior, i.e., a scaling hypothesis, through an exponent α. The latter has demonstrated its usefulness for the investigations of long-range power-law correlations in several types of financial sequences. Our findings show that the α exponent interestingly characterizes fractional Brownian motion of the currency exchange rates between EUR and DKK over a 25 day interval, and usual Brownian motion otherwise and for the three other investigated exchange rates. We can devise an investment strategy based on the localα technique and obtain appreciable gains for the time being.

  14. Reduced nicotine content cigarette advertising: How false beliefs and subjective ratings affect smoking behavior.

    Science.gov (United States)

    Mercincavage, Melissa; Saddleson, Megan L; Gup, Emily; Halstead, Angela; Mays, Darren; Strasser, Andrew A

    2017-04-01

    Tobacco advertising can create false beliefs about health harms that are reinforced by product design features. Reduced nicotine content (RNC) cigarettes may reduce harm, but research has not addressed advertising influences. This study examined RNC cigarette advertising effects on false harm beliefs, and how these beliefs - along with initial subjective ratings of RNC cigarettes - affect subsequent smoking behaviors. We further explored whether subjective ratings moderate associations between false beliefs and behavior. Seventy-seven daily, non-treatment-seeking smokers (66.2% male) participated in the first 15days of a randomized, controlled, open-label RNC cigarette trial. Participants viewed an RNC cigarette advertisement at baseline before completing a 5-day period of preferred brand cigarette use, followed by a 10-day period of RNC cigarette use (0.6mg nicotine yield). Participants provided pre- and post-advertisement beliefs, and subjective ratings and smoking behaviors for cigarettes smoked during laboratory visits. Viewing the advertisement increased beliefs that RNC cigarettes contain less nicotine and are healthier than regular cigarettes (p'saffected smoking behaviors. Significant interactions of strength and taste ratings with beliefs (p'ssmokers with less negative initial subjective ratings, greater false beliefs were associated with greater RNC cigarette consumption. Smokers may misconstrue RNC cigarettes as less harmful than regular cigarettes. These beliefs, in conjunction with favorable subjective ratings, may increase product use. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    Science.gov (United States)

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  16. Locality-sensitive Hashing without False Negatives

    DEFF Research Database (Denmark)

    Pagh, Rasmus

    2016-01-01

    We consider a new construction of locality-sensitive hash functions for Hamming space that is covering in the sense that is it guaranteed to produce a collision for every pair of vectors within a given radius r. The construction is efficient in the sense that the expected number of hash collisions......(n)/k, where n is the number of points in the data set and k ∊ N, and differs from it by at most a factor ln(4) in the exponent for general values of cr. As a consequence, LSH-based similarity search in Hamming space can avoid the problem of false negatives at little or no cost in efficiency. Read More: http...... between vectors at distance cr, for a given c > 1, comes close to that of the best possible data independent LSH without the covering guarantee, namely, the seminal LSH construction of Indyk and Motwani (FOCS ′98). The efficiency of the new construction essentially matches their bound if cr = log...

  17. Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation study

    Directory of Open Access Journals (Sweden)

    Vickers Andrew J

    2008-11-01

    Full Text Available Abstract Background A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives. Methods A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC corrected for verification bias varying both the rate and mechanism of verification. Results In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5th – 97.5th centile range constituted as much as 60% of the possible range of AUCs for some simulations. Conclusion Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.

  18. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Science.gov (United States)

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  19. Enhancing the Statistical Filtering Scheme to Detect False Negative Attacks in Sensor Networks

    Directory of Open Access Journals (Sweden)

    Muhammad Akram

    2017-06-01

    Full Text Available In this paper, we present a technique that detects both false positive and false negative attacks in statistical filtering-based wireless sensor networks. In statistical filtering scheme, legitimate reports are repeatedly verified en route before they reach the base station, which causes heavy energy consumption. While the original statistical filtering scheme detects only false reports, our proposed method promises to detect both attacks.

  20. Staging primary breast cancer. Are there tumour pathological features that correlate with a false-negative axillary ultrasound?

    International Nuclear Information System (INIS)

    Johnson, S.; Brown, S.; Porter, G.; Steel, J.; Paisley, K.; Watkins, R.; Holgate, C.

    2011-01-01

    Aim: To investigate whether the histopathological characteristics of primary breast cancer tumours could predict the likelihood of false-negative axillary ultrasound. Materials and methods: Screening and symptomatic patients were identified from pathology records and imaging and pathology records reviewed. True and false-negative axillary staging ultrasound groups were compared statistically in terms of tumour size, pathological type and grade, lymphovascular invasion, and oestrogen receptor (ER) status. Results: Of 155 women with normal ultrasounds, 45 (29%) were node positive at axillary surgery. Breast tumour size was significantly different with the average size smaller in the true-negative group: 21 versus 30 mm (p < 0.02). The histological type varied significantly between the groups, with more lobular carcinomas in the false-negative group [6/110 (5%) versus 6/45 (13%), p < 0.001]. The false-negative group was also more likely to show lymphovascular invasion in the breast [6/110 (5%) versus 14/45 (31%), p < 0.001]. There was no significant difference in tumour grade or ER status. Conclusion: The present study has found significant differences in tumour characteristics between women with true-negative and false-negative axillary staging ultrasound in terms of size, primary tumour histological type and presence of lymphovascular invasion. In particular, axillary ultrasound in primary lobular carcinoma may be less accurate and a negative result is more likely to be spurious than with primary ductal carcinomas.

  1. False positive or negative results of shear-wave elastography in differentiating benign from malignant breast masses: analysis of clinical and ultrasonographic characteristics.

    Science.gov (United States)

    Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik

    2015-10-01

    Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.

  2. The role of attention at retrieval on the false recognition of negative emotional DRM lists.

    Science.gov (United States)

    Shah, Datin; Knott, Lauren M

    2018-02-01

    This study examined the role of attention at retrieval on the false recognition of emotional items using the Deese-Roediger-McDermott (DRM) paradigm. Previous research has shown that divided attention at test increases false remember judgements for neutral critical lures. However, no research has yet directly assessed emotional false memories when attention is manipulated at retrieval. To examine this, participants studied negative (low in valence and high in arousal) and neutral DRM lists and completed recognition tests under conditions of full and divided attention. Results revealed that divided attention at retrieval increased false remember judgements for all critical lures compared to retrieval under full attention, but in both retrieval conditions, false memories were greater for negative compared to neutral stimuli. We believe that this is due to reliance on a more easily accessible (meaning of the word) but less diagnostic form of source monitoring, amplified under conditions of divided attention.

  3. Performance of computer-aided detection in false-negative screening mammograms of breast cancers

    International Nuclear Information System (INIS)

    Han, Boo Kyung; Kim, Ji Young; Shin, Jung Hee; Choe, Yeon Hyeon

    2004-01-01

    To analyze retrospectively the abnormalities visible on the false-negative screening mammograms of patients with breast cancer and to determine the performance of computer-aided detection (CAD) in the detection of cancers. Of 108 consecutive cases of breast cancer diagnosed over a period of 6 years, of which previous screening mammograms were available, 32 retrospectively visible abnormalities (at which locations cancer later developed) were found in the previous mammograms, and which were originally reported as negative. These 32 patients ranged in age from 38 to 72 years (mean 52 years). We analyzed their previous mammographic findings, and assessed the ability of CAD to mark cancers in previous mammograms, according to the clinical presentation, the type of abnormalities and the mammographic parenchymal density. In these 32 previous mammograms of breast cancers (20 asymptomatic, 12 symptomatic), the retrospectively visible abnormalities were identified as densities in 22, calcifications in 8, and densities with calcifications in 2. CAD marked abnormalities in 20 (63%) of the 32 cancers with false-negative screening mammograms; 14 (70%) of the 20 subsequent screening-detected cancers, 5 (50%) of the 10 interval cancers, and 1 (50%) of the 2 cancers palpable after the screening interval. CAD marked 12 (50%) of the 24 densities and 9 (90%) of the 10 calcifications. CAD marked abnormalities in 7 (50%) of the 14 predominantly fatty breasts, and 13 (72%) of the 18 dense breasts. CAD-assisted diagnosis could potentially decrease the number of false-negative mammograms caused by the failure to recognize the cancer in the screening program, although its usefulness in the prevention of interval cancers appears to be limited

  4. False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis

    Directory of Open Access Journals (Sweden)

    Rudielle A. Rodrigues

    Full Text Available ABSTRACT: According to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT, the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT of the Ministry of Agriculture, Livestock and Food Supply (MAPA, the caudal fold test and the comparative intradermal tuberculin test (CITT. The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4% were negative, 14 (26.4% were positive and seven (13.2% results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0% of the animals with negative CITT results were culture positive (confirmed by PCR and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success.

  5. Generating false negatives and false positives for As and Mo concentrations in groundwater due to well installation.

    Science.gov (United States)

    Wallis, Ilka; Pichler, Thomas

    2018-08-01

    Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested

  6. The semantics of emotion in false memory.

    Science.gov (United States)

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  7. Controlling for false negatives in agent-based models

    DEFF Research Database (Denmark)

    Secchi, Davide; Seri, Raffaello

    2017-01-01

    This article is concerned with the study of statistical power in agent-based modeling (ABM). After an overview of classic statistics theory on how to interpret Type-II error (whose occurrence is also referred to as a false negative) and power, the manuscript presents a study on ABM simulation art...... of simulation runs to reach an appropriate level of power. The study concludes with the importance for organizational behavior scholars to perform their models in an attempt to reach a power of 0.95 or higher at the 0.01 significance level....

  8. False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, Wayne; Krauter, Paula A.; Boucher, Raymond M.; Tezak, Mathew; Amidan, Brett G. (Pacific Northwest National Laboratory, Richland, WA); Piepel, Greg F. (Pacific Northwest National Laboratory, Richland, WA)

    2011-05-01

    Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

  9. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  10. Surgical staging identified false HPV-negative cases in a large series of invasive cervical cancers.

    Science.gov (United States)

    Petry, Karl Ulrich; Liebrich, Clemens; Luyten, Alexander; Zander, Martina; Iftner, Thomas

    2017-12-01

    We examined a large series of biopsy-proven invasive cervical cancers with surgical staging and HPV re-testing to estimate the relevance of HPV-negative cervical cancers in a Caucasian population. We prospectively collected smears from 371 patients with a biopsy-proven diagnosis of cervical cancer for HC2 testing of high-risk HPV (HR-HPV). In HC2-negative cases, smears and paraffin embedded tissue blocks underwent additional HPV genotyping. HC2 tests showed 31/371 cases (8.8%) had negative findings. Surgical staging showed that 21/31 HC2-negative cases (68%) were not cervical cancer. Overall, 340/350 cases of primary cervical cancer confirmed by surgical staging tested HC2 positive (97.2%). Non-high-risk HPV subtypes were detected in five cases (one HPV-53, one HPV-70, and three HPV-73) and high-risk subtypes in four patients with HC2-negative cervical cancer (two HPV 16 and two HPV-18). The remaining case, a primary undifferentiated carcinoma of the uterine cervix, tested negative for HPV-DNA with all tests. The main explanation for HPV-negative cervical cancer was a false diagnosis, followed by cancers associated with non-HR-HPV types, and false-negative HR-HPV results. Truly HPV negative seem to be very rare in Caucasian populations. Retrospective analyses without surgical staging may overestimate the proportion of HPV negative cervical cancers. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. False-negative HIV tests using oral fluid tests in children taking antiretroviral therapy from Harare, Zimbabwe.

    Science.gov (United States)

    Olaru, Ioana D; McHugh, Grace; Dakshina, Suba; Majonga, Edith; Dauya, Ethel; Bandason, Tsitsi; Kranzer, Katharina; Mujuru, Hilda; Ferrand, Rashida A

    2017-08-29

    Rapid diagnostic tests (RDT) for HIV infection have high sensitivity and specificity, but in the setting of longstanding antiretroviral therapy (ART), can give false results that can lead to misinterpretation, confusion and inadequate management. The objective of this study was to evaluate the proportion of falsely negative results of a RDT performed on oral fluid in HIV-infected children on longstanding ART. One hundred and twenty-nine children with known HIV infection and receiving ART were recruited from the HIV Clinic at the Harare Central Hospital, Zimbabwe. HIV testing was performed on oral fluid and on finger-stick blood. Children included in the study had a median age of 12 years (IQR 10-14) and 67 (51.9%) were female. Median age at HIV diagnosis was 5 years (IQR 3-6) and the median time on ART was 6.3 years (IQR 4.3-8.1). The oral fluid test was negative in 11 (8.5%) patients and indeterminate in 2 (1.6%). Finger-stick blood test was negative in 1 patient. Patients with a negative oral fluid test had a higher CD4 cell count (967 vs. 723 cells/mm 3 , p  = 0.016) and a longer time on ART (8.5 vs. 6 years, p  = 0.016). This study found that a substantial proportion of false-negative HIV test results in children on longstanding ART when using an oral fluid test. This could lead to misinterpretation of HIV test results and in the false perception of cure or delayed diagnosis.

  12. Production of sensitivity and false alarm rate

    International Nuclear Information System (INIS)

    Han Zijie; Kang Wu; Chu Chengsheng; Hao Fanhua; Liu Xiaoya; Cao Lin; Hu Yongbo; Gong Jian; Xiang Yongchun; Zhang Jianhua; Yang Xiangdong

    2007-01-01

    The false alarm rate and sensitivity in nuclear material monitoring system are affected by alarm principle. Two different alarm principles are studied with theory and experiment analysis in this paper. Our research shows that theory analysis and experiment result are accordant very much. This study provides technology support for designing better alarm principle in nuclear material monitoring system. (authors)

  13. Partial hydatidiform mole with false-negative urine human chorionic gonadatropin test in the emergency department.

    Science.gov (United States)

    Mundangepfupfu, Tichaendepi; Waseem, Muhammad

    2014-03-01

    Hydatidiform mole (molar pregnancy) is a benign tumor of placental trophoblastic cells, which release human chorionic gonadotropin (hCG). Several case reports have described complete hydatidiform moles with false-negative urine qualitative hCG tests. These negative pregnancy tests have been attributed to the hook effect. We report an unusual presentation of a partial mole and review an alternative explanation for the negative hCG test. As partial moles are usually not associated with a large proliferation of trophoblastic cells, levels of hCG are commonly negative and serum quantitative hCG was 1,094,950 mIU/mL. Pelvic ultrasonography showed a uterine cavity containing a soft-tissue mass with multiple cystic lesions and the hydatidiform mole was extracted with suction curettage. Tissue pathology confirmed partial hydatidiform mole. In addition to the hook effect, we present another possible explanation for the false-negative test; namely the inability of some assays to detect hCG-degradation products, which may be higher in clinical samples from patients with hydatidiform mole. This case underscores the importance of knowing the limitations of the commonly used hCG assays. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  15. False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.

    Science.gov (United States)

    Katz, Alan R; Komeya, Alan Y; Tomas, Juval E

    2017-06-01

    We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.

  16. False Negative Mammogram of Breast Cancer : Analysis of Mammographic and Sonographic Findings and Correlation with Clinical Findings

    International Nuclear Information System (INIS)

    Lee, Kil Jun; Lee, Ji Yeon; Han, Sung Nim; Jeong, Seong Ki; Tae, Seok; Shin, Kyoung Ja; Lee, Sang Chun

    1995-01-01

    Recent mammographic equipment have been of good quality and yielded high diagnostic accuracy for the detection of breast cancer. However, negative mammogram does not necessarily rule out breast cancer. Therefore were viewed cause of false negative mammography in confirmed breast cancer to improve diagnostic accuracy and for adequate clinical approach. We reviewed 19 cases of confirmed breast cancer, which showed false negative mammography with positive sonographic findings. Retrospective analysis was done by correlating the patient's age, sonographic finding and mass size, mammographic breast pattern and cause of false negative mammogram, and clinical symptoms. Among the 5 patients below 35 years in age, mass was not visible due to dense breast in 4 and due to small size in 1 case. In 14 patients over 35 years in age, 11 had normal mammographic findings, 4 had dense breast, and 7 had small sized mass. Remaining 3 cases showed asymmetric density in 2 and architecture distortion in 1 case. All showed mass lesion in sonography : ill defined malignant appearance in 14,well defined malignant appearance in 2, and well defined benign in 3 cases. Negative mammogram should be correlated with sonography in case of dense breast, below 35 years in age with palpable mass and under risk for breast cancer

  17. Negative Interest Rates: Central Banks Initiated an Experiment

    Directory of Open Access Journals (Sweden)

    Aleksey N. Burenin

    2016-01-01

    Full Text Available Negative interest rates appeared as a consequence of economic problems that countries with market economy came across after the crises of2007-2008. The attempts of monetary authorities to stimulate economies with the help of quantitative easing didn't bring the desired result. That's why the central banks once again resorted to a traditional tool of their monetary policy of changing interest rates. But this time they launched an experiment, they used negative interest rates. The European Central Bank, the Swedish Riksbank, the Bank of Japan, and the National Bank of Hungary introduced negative rates in order to stimulate economic growth and fight the threat of deflation, the Danish National Bank and the Swiss National Bank tried to deter appreciation of their currencies. Negative rates of the central banks brought about negative yields of government and nongovernment securities in several countries. The problem acquires an aggravated form due to the fact that negative rates appeared in several European countries simultaneously at the moment when global financial markets were not in crises. Some questions arise concerning the negative rates, for example, how low can central banks bring down the rates in the future, what is their influence on the stock markets, what is the reaction of depositors to the introduction of negative deposit rates by commercial banks, must one consider a negative rate as a rate of interest or payment to store money of the depositor, in which circumstances negative rates can be justified to fight deflation. The last question plays an important role, because recent studies find that positive economic growth is possible during deflation. If central banks don't take this nuance into consideration, they can create economic imbalances by increasing liquidity. Negative rates are not as inoffensive as it may seem at first glance. Not far ago an investor, who tried to averse risk, was buying government securities. Their yields

  18. False negative newborn screen and neonatal cholestasis in a premature child with cystic fibrosis

    NARCIS (Netherlands)

    Heidendael, J. F.; Tabbers, M. M.; de Vreede, I.

    2014-01-01

    Newborn screening for cystic fibrosis enables early diagnosis and treatment, leading to better outcomes for patients with cystic fibrosis. Although the sensitivity of several screening protocols is high, false negative screening results of the newborn patient still occur, which can lead to a

  19. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  20. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  1. Bloodstains on Leather: Examination of False Negatives in Presumptive Test and Human Hemoglobin Test.

    Science.gov (United States)

    Castelló, Ana; Francès, Francesc; Verdú, Fernando

    2017-09-01

    Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.

  2. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    International Nuclear Information System (INIS)

    Poortman, Pieter; Lohle, Paul N.M.; Schoemaker, Cees M.; Cuesta, Miguel A.; Oostvogel, Henk J.M.; Lange-de Klerk, Elly S.M. de; Hamming, Jaap F.

    2010-01-01

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  3. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Poortman, Pieter [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: ppoortman@wlz.nl; Lohle, Paul N.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: plohle@elisabeth.nl; Schoemaker, Cees M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: mcschoemaker@elisabeth.nl; Cuesta, Miguel A. [Department of Surgery, VU Medical Centre, Amsterdam (Netherlands)], E-mail: ma.cuesta@vumc.nl; Oostvogel, Henk J.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: h.oostvogel@elisabeth.nl; Lange-de Klerk, Elly S.M. de [Department of Epidemiology and Biostatistics, VU Medical Centre, Amsterdam (Netherlands)], E-mail: esm.delange@vumc.nl; Hamming, Jaap F. [Department of Surgery, Leiden University Medical Centre (Netherlands)], E-mail: j.f.hamming@lumc.nl

    2010-04-15

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  4. Improvement of human cell line activation test (h-CLAT) using short-time exposure methods for prevention of false-negative results.

    Science.gov (United States)

    Narita, Kazuto; Ishii, Yuuki; Vo, Phuc Thi Hong; Nakagawa, Fumiko; Ogata, Shinichi; Yamashita, Kunihiko; Kojima, Hajime; Itagaki, Hiroshi

    2018-01-01

    Recently, animal testing has been affected by increasing ethical, social, and political concerns regarding animal welfare. Several in vitro safety tests for evaluating skin sensitization, such as the human cell line activation test (h-CLAT), have been proposed. However, similar to other tests, the h-CLAT has produced false-negative results, including in tests for acid anhydride and water-insoluble chemicals. In a previous study, we demonstrated that the cause of false-negative results from phthalic anhydride was hydrolysis by an aqueous vehicle, with IL-8 release from THP-1 cells, and that short-time exposure to liquid paraffin (LP) dispersion medium could reduce false-negative results from acid anhydrides. In the present study, we modified the h-CLAT by applying this exposure method. We found that the modified h-CLAT is a promising method for reducing false-negative results obtained from acid anhydrides and chemicals with octanol-water partition coefficients (LogK ow ) greater than 3.5. Based on the outcomes from the present study, a combination of the original and the modified h-CLAT is suggested for reducing false-negative results. Notably, the combination method provided a sensitivity of 95% (overall chemicals) or 93% (chemicals with LogK ow > 2.0), and an accuracy of 88% (overall chemicals) or 81% (chemicals with LogK ow > 2.0). We found that the combined method is a promising evaluation scheme for reducing false-negative results seen in existing in vitro skin-sensitization tests. In the future, we expect a combination of original and modified h-CLAT to be applied in a newly developed in vitro test for evaluating skin sensitization.

  5. Intersubject Differences in False Nonmatch Rates for a Fingerprint-Based Authentication System

    Directory of Open Access Journals (Sweden)

    Jeroen Breebaart

    2009-01-01

    Full Text Available The intersubject dependencies of false nonmatch rates were investigated for a minutiae-based biometric authentication process using single enrollment and verification measurements. A large number of genuine comparison scores were subjected to statistical inference tests that indicated that the number of false nonmatches depends on the subject and finger under test. This result was also observed if subjects associated with failures to enroll were excluded from the test set. The majority of the population (about 90% showed a false nonmatch rate that was considerably smaller than the average false nonmatch rate of the complete population. The remaining 10% could be characterized as “goats” due to their relatively high probability for a false nonmatch. The image quality reported by the template extraction module only weakly correlated with the genuine comparison scores. When multiple verification attempts were investigated, only a limited benefit was observed for “goats,” since the conditional probability for a false nonmatch given earlier nonsuccessful attempts increased with the number of attempts. These observations suggest that (1 there is a need for improved identification of “goats” during enrollment (e.g., using dedicated signal-driven analysis and classification methods and/or the use of multiple enrollment images and (2 there should be alternative means for identity verification in the biometric system under test in case of two subsequent false nonmatches.

  6. Prime time news: the influence of primed positive and negative emotion on susceptibility to false memories.

    Science.gov (United States)

    Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha

    2014-01-01

    We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.

  7. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    Energy Technology Data Exchange (ETDEWEB)

    Portnoy, David, E-mail: david.portnoy@jhuapl.edu [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Feuerbach, Robert; Heimberg, Jennifer [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States)

    2011-10-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the 'threat' set of

  8. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    International Nuclear Information System (INIS)

    Portnoy, David; Feuerbach, Robert; Heimberg, Jennifer

    2011-01-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the 'threat' set of spectra

  9. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    Science.gov (United States)

    Portnoy, David; Feuerbach, Robert; Heimberg, Jennifer

    2011-10-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the "threat" set of spectra

  10. Ultrasound imaging in children with acute abdominal pain - can it help to decrease the rate of negative appendectomies?

    International Nuclear Information System (INIS)

    Niedzielski, J.; Miodek, M.; Kucharski, P.; Sokal, J.

    2010-01-01

    Background: The purpose of this study was to evaluate the accuracy of high-resolution ultrasound (US) with graded compression in the diagnosis of pediatric appendicitis.Material/Methods: The medical records of 664 consecutive children with acute abdominal pain treated between 2007 and 2009 were reviewed retrospectively and analyzed; 408 children (61.4 %) underwent appendectomy and 256 patients were treated conservatively (38.6 %). High-resolution US was performed in 570 out of 664 patients (85.8 %). The US data were verified by intraoperative findings or by clinical follow-up. Results: Out of 664 children, 408 underwent appendectomy and 256 were treated conservatively. US was performed in 570 out of 664 children (85.8 %); in 327/408 children (80.1 %) with AA and in 243/256 children (94.9 %) with negative diagnosis. The sensitivity and specificity for US was 66.6% and 77.4%, respectively. If histopathological diagnosis of catarrhal appendicitis was considered a negative (unnecessary) appendectomy, the sensitivity was 68.6 % (p=0.87), and specificity was 67 % (p=0.29). Positive and negative predictive values of US were 79.9 % and 63.1 %, respectively. After recalculating results, positive predictive value decreased to 59.8% (p=0.036) and negative predictive value increased to 74.8 % (p=0.2). The rate of false negative results was 13.1 % (75/572) and the rate of false positives was 19.2 % (110/572). The negative appendectomy rate was 27.4 % (112/408). Conclusions: High-resolution ultrasonography provides an accurate and specific test for acute appendicitis and is recommended by the authors as an examination of choice in children with acute abdominal pain. (authors)

  11. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    Science.gov (United States)

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  12. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  13. [EXPERIENCE OF STUDY AND POSSIBLE WAYS OF ELIMINATION OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS DURING EXECUTION OF POLYMERASE CHAIN REACTION ON AN EXAMPLE OF JUNIN VIRUS RNA DETECTION].

    Science.gov (United States)

    Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A

    2015-01-01

    Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the

  14. Dogs cannot bark: event-related brain responses to true and false negated statements as indicators of higher-order conscious processing.

    Science.gov (United States)

    Herbert, Cornelia; Kübler, Andrea

    2011-01-01

    The present study investigated event-related brain potentials elicited by true and false negated statements to evaluate if discrimination of the truth value of negated information relies on conscious processing and requires higher-order cognitive processing in healthy subjects across different levels of stimulus complexity. The stimulus material consisted of true and false negated sentences (sentence level) and prime-target expressions (word level). Stimuli were presented acoustically and no overt behavioral response of the participants was required. Event-related brain potentials to target words preceded by true and false negated expressions were analyzed both within group and at the single subject level. Across the different processing conditions (word pairs and sentences), target words elicited a frontal negativity and a late positivity in the time window from 600-1000 msec post target word onset. Amplitudes of both brain potentials varied as a function of the truth value of the negated expressions. Results were confirmed at the single-subject level. In sum, our results support recent suggestions according to which evaluation of the truth value of a negated expression is a time- and cognitively demanding process that cannot be solved automatically, and thus requires conscious processing. Our paradigm provides insight into higher-order processing related to language comprehension and reasoning in healthy subjects. Future studies are needed to evaluate if our paradigm also proves sensitive for the detection of consciousness in non-responsive patients.

  15. Dogs cannot bark: event-related brain responses to true and false negated statements as indicators of higher-order conscious processing.

    Directory of Open Access Journals (Sweden)

    Cornelia Herbert

    Full Text Available The present study investigated event-related brain potentials elicited by true and false negated statements to evaluate if discrimination of the truth value of negated information relies on conscious processing and requires higher-order cognitive processing in healthy subjects across different levels of stimulus complexity. The stimulus material consisted of true and false negated sentences (sentence level and prime-target expressions (word level. Stimuli were presented acoustically and no overt behavioral response of the participants was required. Event-related brain potentials to target words preceded by true and false negated expressions were analyzed both within group and at the single subject level. Across the different processing conditions (word pairs and sentences, target words elicited a frontal negativity and a late positivity in the time window from 600-1000 msec post target word onset. Amplitudes of both brain potentials varied as a function of the truth value of the negated expressions. Results were confirmed at the single-subject level. In sum, our results support recent suggestions according to which evaluation of the truth value of a negated expression is a time- and cognitively demanding process that cannot be solved automatically, and thus requires conscious processing. Our paradigm provides insight into higher-order processing related to language comprehension and reasoning in healthy subjects. Future studies are needed to evaluate if our paradigm also proves sensitive for the detection of consciousness in non-responsive patients.

  16. Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture.

    Science.gov (United States)

    Hutchison, J R; Piepel, G F; Amidan, B G; Hess, B M; Sydor, M A; Deatherage Kaiser, B L

    2018-05-01

    We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials and assay methods on false-negative rate (FNR) and limit of detection (LOD 95 ) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2-500 per coupon) onto glass, stainless steel, vinyl tile and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD 95 results. Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD 95 was lowest for glass and highest for vinyl tile. LOD 95 values overall were lower for mRV-PCR than for the culture method. This study adds to the limited data on FNR and LOD 95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis. © 2018 The Society for Applied Microbiology.

  17. Effects of depressive disorder on false memory for emotional information.

    Science.gov (United States)

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  18. Negative Interest Rates: Central Banks Initiated an Experiment

    OpenAIRE

    Aleksey N. Burenin

    2016-01-01

    Negative interest rates appeared as a consequence of economic problems that countries with market economy came across after the crises of2007-2008. The attempts of monetary authorities to stimulate economies with the help of quantitative easing didn't bring the desired result. That's why the central banks once again resorted to a traditional tool of their monetary policy of changing interest rates. But this time they launched an experiment, they used negative interest rates. The European Cent...

  19. A comparative review of estimates of the proportion unchanged genes and the false discovery rate

    Directory of Open Access Journals (Sweden)

    Broberg Per

    2005-08-01

    regarding false positive and negative rates as well as the proportion unchanged when identifying changed genes.

  20. Affective valence influences participant's susceptibility to false memories and illusory recollection.

    Science.gov (United States)

    Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial

    2010-10-01

    This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  1. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm²). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD₉₅ was lowest for glass (0.429 CFU/cm² with BAS and 0.341 CFU/cm² with BG) and highest for vinyl tile (0.919 CFU/cm² with BAS and 0.917 CFU/cm² with BG). These mRV-PCR LOD₉₅ values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm² and BG: 0.820 to 1.489 CFU/cm²). The FNR and LOD₉₅ values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  2. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L.D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm2). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD95 was lowest for glass (0.429 CFU/cm2 with BAS and 0.341 CFU/cm2 with BG) and highest for vinyl tile (0.919 CFU/cm2 with BAS and 0.917 CFU/cm2 with BG). These mRV-PCR LOD95 values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm2 and BG: 0.820 to 1.489 CFU/cm2). The FNR and LOD95 values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  3. Magnetic resonance imaging of lumbar spine disc diseases. Frequency of false negatives; Imagerie par resonance magnetique pour pathologie discale lombaire. Frequence des faux-negatifs

    Energy Technology Data Exchange (ETDEWEB)

    Berthelot, J.M.; Maugars, Y.; Delecrin, Y.; Caillon, F.; Prost, A. [Hopital Hotel-Dieu de Nantes, 44 (France)

    1995-10-01

    Magnetic resonance imaging (MRI) has had an impressive impact on evaluation of degenerative diseases of the spine. Nevertheless, false negatives can occur on images involving lumbar discs. Degenerative disc diseases documented on discography and/or pathology examination of the discs can go unrecognized. Likewise sensitivity for the detection of protruding disc hernias is not totally satisfactory (20% false negatives). Finally, a magnetic resonance image visualizing displacement of the disc is not specific (10 to 15% false positives); images showing protrusion or hernia can be seen in 30% of asymptomatic patients. Although MRI gives slightly more information than other imaging techniques, false images do exist. Moreover, the usefulness of MRI to demonstrate disc disease in case of a negative CT-scan remains to be demonstrated. (authors). 26 refs.

  4. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  5. Testing jumps via false discovery rate control.

    Science.gov (United States)

    Yen, Yu-Min

    2013-01-01

    Many recently developed nonparametric jump tests can be viewed as multiple hypothesis testing problems. For such multiple hypothesis tests, it is well known that controlling type I error often makes a large proportion of erroneous rejections, and such situation becomes even worse when the jump occurrence is a rare event. To obtain more reliable results, we aim to control the false discovery rate (FDR), an efficient compound error measure for erroneous rejections in multiple testing problems. We perform the test via the Barndorff-Nielsen and Shephard (BNS) test statistic, and control the FDR with the Benjamini and Hochberg (BH) procedure. We provide asymptotic results for the FDR control. From simulations, we examine relevant theoretical results and demonstrate the advantages of controlling the FDR. The hybrid approach is then applied to empirical analysis on two benchmark stock indices with high frequency data.

  6. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    Science.gov (United States)

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013

  7. With sadness comes accuracy; with happiness, false memory: mood and the false memory effect.

    Science.gov (United States)

    Storbeck, Justin; Clore, Gerald L

    2005-10-01

    The Deese-Roediger-McDermott paradigm lures people to produce false memories. Two experiments examined whether induced positive or negative moods would influence this false memory effect. The affect-as-information hypothesis predicts that, on the one hand, positive affective cues experienced as task-relevant feedback encourage relational processing during encoding, which should enhance false memory effects. On the other hand, negative affective cues are hypothesized to encourage item-specific processing at encoding, which should discourage such effects. The results of Experiment 1 are consistent with these predictions: Individuals in negative moods were significantly less likely to show false memory effects than those in positive moods or those whose mood was not manipulated. Experiment 2 introduced inclusion instructions to investigate whether moods had their effects at encoding or retrieval. The results replicated the false memory finding of Experiment 1 and provide evidence that moods influence the accessibility of lures at encoding, rather than influencing monitoring at retrieval of whether lures were actually presented.

  8. Use of the false discovery rate for evaluating clinical safety data.

    Science.gov (United States)

    Mehrotra, Devan V; Heyse, Joseph F

    2004-06-01

    Clinical adverse experience (AE) data are routinely evaluated using between group P values for every AE encountered within each of several body systems. If the P values are reported and interpreted without multiplicity considerations, there is a potential for an excess of false positive findings. Procedures based on confidence interval estimates of treatment effects have the same potential for false positive findings as P value methods. Excess false positive findings can needlessly complicate the safety profile of a safe drug or vaccine. Accordingly, we propose a novel method for addressing multiplicity in the evaluation of adverse experience data arising in clinical trial settings. The method involves a two-step application of adjusted P values based on the Benjamini and Hochberg false discovery rate (FDR). Data from three moderate to large vaccine trials are used to illustrate our proposed 'Double FDR' approach, and to reinforce the potential impact of failing to account for multiplicity. This work was in collaboration with the late Professor John W. Tukey who coined the term 'Double FDR'.

  9. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    International Nuclear Information System (INIS)

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  10. Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, J. R. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Piepel, G. F. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Amidan, B. G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Hess, B. M. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Sydor, M. A. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Deatherage Kaiser, B. L. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2018-03-13

    Aims: We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials, and assay methods on false-negative rate (FNR) and limit of detection (LOD95) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Methods and Results: Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2 – 500 coupon-1) onto glass, stainless steel, vinyl tile, and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. Conclusions: Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. Significance and Impact of Study: This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.

  11. Intellectual factors in false memories of patients with schizophrenia.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun

    2018-07-01

    The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Testing jumps via false discovery rate control.

    Directory of Open Access Journals (Sweden)

    Yu-Min Yen

    Full Text Available Many recently developed nonparametric jump tests can be viewed as multiple hypothesis testing problems. For such multiple hypothesis tests, it is well known that controlling type I error often makes a large proportion of erroneous rejections, and such situation becomes even worse when the jump occurrence is a rare event. To obtain more reliable results, we aim to control the false discovery rate (FDR, an efficient compound error measure for erroneous rejections in multiple testing problems. We perform the test via the Barndorff-Nielsen and Shephard (BNS test statistic, and control the FDR with the Benjamini and Hochberg (BH procedure. We provide asymptotic results for the FDR control. From simulations, we examine relevant theoretical results and demonstrate the advantages of controlling the FDR. The hybrid approach is then applied to empirical analysis on two benchmark stock indices with high frequency data.

  13. Distance Sensitive Bloom Filters Without False Negatives

    DEFF Research Database (Denmark)

    Goswami, Mayank; Pagh, Rasmus; Silvestri, Francesco

    2017-01-01

    A Bloom filter is a widely used data-structure for representing a set S and answering queries of the form “Is x in S?”. By allowing some false positive answers (saying ‘yes’ when the answer is in fact ‘no’) Bloom filters use space significantly below what is required for storing S. In the distanc...

  14. Effects of maternal negativity and of early and recent recurrent depressive disorder on children's false belief understanding.

    Science.gov (United States)

    Rohrer, Lisa M; Cicchetti, Dante; Rogosch, Fred A; Toth, Sheree L; Maughan, Angeline

    2011-01-01

    Research has shown that children of depressed mothers are at risk for problems in a variety of developmental domains; however, little is known about the effects of maternal depression on children's emerging understanding of false beliefs. In this study, 3 false belief tasks were administered to 5-year-old children whose mothers had either met criteria for major depressive disorder within the first 20 months of the child's life (n = 91) or had never been depressed (n = 50). Significant difficulties in performance were found among the children of depressed mothers, especially those whose mothers had experienced early and recent recurrent depressive disorder. Regardless of diagnostic status, children whose mothers exhibited negativity during problem-solving tasks administered at an earlier developmental period also were less likely to demonstrate false belief understanding. These effects remained even after child verbal ability was controlled.

  15. E-commerce Review System to Detect False Reviews.

    Science.gov (United States)

    Kolhar, Manjur

    2017-08-15

    E-commerce sites have been doing profitable business since their induction in high-speed and secured networks. Moreover, they continue to influence consumers through various methods. One of the most effective methods is the e-commerce review rating system, in which consumers provide review ratings for the products used. However, almost all e-commerce review rating systems are unable to provide cumulative review ratings. Furthermore, review ratings are influenced by positive and negative malicious feedback ratings, collectively called false reviews. In this paper, we proposed an e-commerce review system framework developed using the cumulative sum method to detect and remove malicious review ratings.

  16. Arousal—But Not Valence—Reduces False Memories at Retrieval

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods–similar in arousal levels–correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval. PMID:26938737

  17. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    Directory of Open Access Journals (Sweden)

    Chiara Mirandola

    Full Text Available Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1 whether valence and arousal equally affect false memory production, and (2 whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently, compared to individuals in neutral mood. This suggests that arousal (but not valence predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  18. Inferential false memories of events: negative consequences protect from distortions when the events are free from further elaboration.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico; Grassano, Massimo; Cornoldi, Cesare; Melinder, Annika

    2014-01-01

    The present experiment was conducted to investigate whether negative emotionally charged and arousing content of to-be-remembered scripted material would affect propensity towards memory distortions. We further investigated whether elaboration of the studied material through free recall would affect the magnitude of memory errors. In this study participants saw eight scripts. Each of the scripts included an effect of an action, the cause of which was not presented. Effects were either negatively emotional or neutral. Participants were assigned to either a yes/no recognition test group (recognition), or to a recall and yes/no recognition test group (elaboration + recognition). Results showed that participants in the recognition group produced fewer memory errors in the emotional condition. Conversely, elaboration + recognition participants had lower accuracy and produced more emotional memory errors than the other group, suggesting a mediating role of semantic elaboration on the generation of false memories. The role of emotions and semantic elaboration on the generation of false memories is discussed.

  19. Occurrence of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae isolates.

    Directory of Open Access Journals (Sweden)

    Peng Wang

    Full Text Available Adequate detection of the production of carbapenemase in Enterobacteriaceae isolates is crucial for infection control measures and the appropriate choice of antimicrobial therapy. In this study, we investigated the frequency of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae clinical isolates by the modified Hodge test (MHT. Three hundred and one E. coli and K. pneumoniae clinical isolates were investigated. All produced extended spectrum β-lactamases (ESBLs but were susceptible to carbapenems. Antimicrobial susceptibility testing was performed by the disk diffusion and agar dilution methods. The MHT was performed using the standard inoculum of test organisms recommended by the CLSI. Genes that encoded ESBLs and carbapenemases were identified by PCR and DNA sequencing. Among the 301 clinical isolates, none of the isolates conformed to the criteria for carbapenemase screening recommended by the CLSI. The susceptibility rates for imipenem, meropenem, and ertapenem all were 100.0%, 100.0%, and 100.0%, respectively. Of the 301 E. coli and K. pneumoniae isolates, none produced carbapenemase. The MHT gave a positive result for 3.3% (10/301 of the isolates. False positive results can occur when the MHT is used to detect carbapenemase in ESBL-producing isolates and clinical laboratories must be aware of this fact.

  20. Negative ratings play a positive role in information filtering

    Science.gov (United States)

    Zeng, Wei; Zhu, Yu-Xiao; Lü, Linyuan; Zhou, Tao

    2011-11-01

    The explosive growth of information asks for advanced information filtering techniques to solve the so-called information overload problem. A promising way is the recommender system which analyzes the historical records of users’ activities and accordingly provides personalized recommendations. Most recommender systems can be represented by user-object bipartite networks where users can evaluate and vote for objects, and ratings such as “dislike” and “I hate it” are treated straightforwardly as negative factors or are completely ignored in traditional approaches. Applying a local diffusion algorithm on three benchmark data sets, MovieLens, Netflix and Amazon, our study arrives at a very surprising result, namely the negative ratings may play a positive role especially for very sparse data sets. In-depth analysis at the microscopic level indicates that the negative ratings from less active users to less popular objects could probably have positive impacts on the recommendations, while the ones connecting active users and popular objects mostly should be treated negatively. We finally outline the significant relevance of our results to the two long-term challenges in information filtering: the sparsity problem and the cold-start problem.

  1. A constrained polynomial regression procedure for estimating the local False Discovery Rate

    Directory of Open Access Journals (Sweden)

    Broët Philippe

    2007-06-01

    Full Text Available Abstract Background In the context of genomic association studies, for which a large number of statistical tests are performed simultaneously, the local False Discovery Rate (lFDR, which quantifies the evidence of a specific gene association with a clinical or biological variable of interest, is a relevant criterion for taking into account the multiple testing problem. The lFDR not only allows an inference to be made for each gene through its specific value, but also an estimate of Benjamini-Hochberg's False Discovery Rate (FDR for subsets of genes. Results In the framework of estimating procedures without any distributional assumption under the alternative hypothesis, a new and efficient procedure for estimating the lFDR is described. The results of a simulation study indicated good performances for the proposed estimator in comparison to four published ones. The five different procedures were applied to real datasets. Conclusion A novel and efficient procedure for estimating lFDR was developed and evaluated.

  2. Delayed diagnosis of childhood deafness: the value of false negatives in the Programme for Early Detection of Neonatal Hearing Loss.

    Science.gov (United States)

    Martínez-Pacheco, María C; Ferrán de la Cierva, Luis; García-Purriños, Francisco J

    Despite its importance, the existence of false negatives (patients who are told they hear well, but they have some degree of hipacusia) is rarely evaluated in programs for early detection of hearing loss. The aim of this study is to determine the variables that can lead to a delayed diagnosis, especially the existence of false negatives and the lack of registration of risk factors. A retrospective study of prevalence has been carried out, in which the medical records of children diagnosed with sensorineural hearing loss born within 2005 and 2012 in the health centers of study have been analyzed. Of the 32 children with sensorineural hearing loss, 16 passed the OAE, 12 did not passed the OAE, and in four they were not carried out. Of the children who passed the OAE, 57% have severe hearing loss. 66% of children with hearing loss presented a risk factor for hearing loss at birth, being the most frecuent family history of hearing loss, but only 7% of those with family history of hearing loss were included in the risk group. The results of the study indicate that the late diagnosis of hearing loss is related to the presence of false negatives to the OAE and the non-registration of risk factors. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  3. Too Good to be False: Nonsignificant Results Revisited

    Directory of Open Access Journals (Sweden)

    Chris H. J. Hartgerink

    2017-03-01

    Full Text Available Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant findings may just be ‘too good to be false’. We examined evidence for false negatives in nonsignificant results in three different ways. We adapted the Fisher test to detect the presence of at least one false negative in a set of statistically nonsignificant results. Simulations show that the adapted Fisher method generally is a powerful method to detect false negatives. We examined evidence for false negatives in the psychology literature in three applications of the adapted Fisher method. These applications indicate that (i the observed effect size distribution of nonsignificant effects exceeds the expected distribution assuming a null-effect, and approximately two out of three (66.7% psychology articles reporting nonsignificant results contain evidence for at least one false negative, (ii nonsignificant results on gender effects contain evidence of true nonzero effects, and (iii the statistically nonsignificant replications from the Reproducibility Project Psychology (RPP do not warrant strong conclusions about the absence or presence of true zero effects underlying these nonsignificant results. We conclude that false negatives deserve more attention in the current debate on statistical practices in psychology. Potentially neglecting effects due to a lack of statistical power can lead to a waste of research resources and stifle the scientific discovery process.

  4. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-16

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

  5. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

  6. Working memory affects false memory production for emotional events.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare

    2017-01-01

    Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.

  7. 47 CFR 76.981 - Negative option billing.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Negative option billing. 76.981 Section 76.981 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Rate Regulation § 76.981 Negative option billing. (a) A cable operator...

  8. Effects of Maternal Negativity and of Early and Recent Recurrent Depressive Disorder on Children’s False Belief Understanding

    Science.gov (United States)

    Rohrer, Lisa M.; Cicchetti, Dante; Rogosch, Fred A.; Toth, Sheree L.; Maughan, Angeline

    2015-01-01

    Research has shown that children of depressed mothers are at risk for problems in a variety of developmental domains; however, little is known about the effects of maternal depression on children’s emerging understanding of false beliefs. In this study, three false belief tasks were administered to five-year-old children whose mothers had either met criteria for major depressive disorder within the first 20 months of the child’s life (n = 91) or had never been depressed (n = 50). Significant difficulties in performance were found among the children of depressed mothers, especially those whose mothers had experienced early and recent recurrent depressive disorder. Regardless of diagnostic status, children whose mothers exhibited negativity during problem-solving tasks administered at an earlier developmental period also were less likely to demonstrate false belief understanding. These effects remained even after child verbal ability was controlled. PMID:21244156

  9. Adaptive false memory: Imagining future scenarios increases false memories in the DRM paradigm.

    Science.gov (United States)

    Dewhurst, Stephen A; Anderson, Rachel J; Grace, Lydia; van Esch, Lotte

    2016-10-01

    Previous research has shown that rating words for their relevance to a future scenario enhances memory for those words. The current study investigated the effect of future thinking on false memory using the Deese/Roediger-McDermott (DRM) procedure. In Experiment 1, participants rated words from 6 DRM lists for relevance to a past or future event (with or without planning) or in terms of pleasantness. In a surprise recall test, levels of correct recall did not vary between the rating tasks, but the future rating conditions led to significantly higher levels of false recall than the past and pleasantness conditions did. Experiment 2 found that future rating led to higher levels of false recognition than did past and pleasantness ratings but did not affect correct recognition. The effect in false recognition was, however, eliminated when DRM items were presented in random order. Participants in Experiment 3 were presented with both DRM lists and lists of unrelated words. Future rating increased levels of false recognition for DRM lures but did not affect correct recognition for DRM or unrelated lists. The findings are discussed in terms of the view that false memories can be associated with adaptive memory functions.

  10. Controlling the Rate of GWAS False Discoveries.

    Science.gov (United States)

    Brzyski, Damian; Peterson, Christine B; Sobczyk, Piotr; Candès, Emmanuel J; Bogdan, Malgorzata; Sabatti, Chiara

    2017-01-01

    With the rise of both the number and the complexity of traits of interest, control of the false discovery rate (FDR) in genetic association studies has become an increasingly appealing and accepted target for multiple comparison adjustment. While a number of robust FDR-controlling strategies exist, the nature of this error rate is intimately tied to the precise way in which discoveries are counted, and the performance of FDR-controlling procedures is satisfactory only if there is a one-to-one correspondence between what scientists describe as unique discoveries and the number of rejected hypotheses. The presence of linkage disequilibrium between markers in genome-wide association studies (GWAS) often leads researchers to consider the signal associated to multiple neighboring SNPs as indicating the existence of a single genomic locus with possible influence on the phenotype. This a posteriori aggregation of rejected hypotheses results in inflation of the relevant FDR. We propose a novel approach to FDR control that is based on prescreening to identify the level of resolution of distinct hypotheses. We show how FDR-controlling strategies can be adapted to account for this initial selection both with theoretical results and simulations that mimic the dependence structure to be expected in GWAS. We demonstrate that our approach is versatile and useful when the data are analyzed using both tests based on single markers and multiple regression. We provide an R package that allows practitioners to apply our procedure on standard GWAS format data, and illustrate its performance on lipid traits in the North Finland Birth Cohort 66 cohort study. Copyright © 2017 by the Genetics Society of America.

  11. Effects of hydrocortisone on false memory recognition in healthy men and women.

    Science.gov (United States)

    Duesenberg, Moritz; Weber, Juliane; Schaeuffele, Carmen; Fleischer, Juliane; Hellmann-Regen, Julian; Roepke, Stefan; Moritz, Steffen; Otte, Christian; Wingenfeld, Katja

    2016-12-01

    Most of the studies focusing on the effect of stress on false memories by using psychosocial and physiological stressors yielded diverse results. In the present study, we systematically tested the effect of exogenous hydrocortisone using a false memory paradigm. In this placebo-controlled study, 37 healthy men and 38 healthy women (mean age 24.59 years) received either 10 mg of hydrocortisone or placebo 75 min before using the false memory, that is, Deese-Roediger-McDermott (DRM), paradigm. We used emotionally charged and neutral DRM-based word lists to look for false recognition rates in comparison to true recognition rates. Overall, we expected an increase in false memory after hydrocortisone compared to placebo. No differences between the cortisol and the placebo group were revealed for false and for true recognition performance. In general, false recognition rates were lower compared to true recognition rates. Furthermore, we found a valence effect (neutral, positive, negative, disgust word stimuli), indicating higher rates of true and false recognition for emotional compared to neutral words. We further found an interaction effect between sex and recognition. Post hoc t tests showed that for true recognition women showed a significantly better memory performance than men, independent of treatment. This study does not support the hypothesis that cortisol decreases the ability to distinguish between old versus novel words in young healthy individuals. However, sex and emotional valence of word stimuli appear to be important moderators. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  12. A comparative analysis of molecular genetic and conventional cytogenetic detection of diagnostically important translocations in more than 400 cases of acute leukemia, highlighting the frequency of false-negative conventional cytogenetics.

    Science.gov (United States)

    King, Rebecca L; Naghashpour, Mojdeh; Watt, Christopher D; Morrissette, Jennifer J D; Bagg, Adam

    2011-06-01

    In this study, we correlated the results of concurrent molecular and cytogenetic detection of entity-defining translocations in adults with acute leukemia to determine the frequency of cryptic translocations missed by conventional cytogenetics (CC) and of recurrent, prognostically relevant translocations not detectable by multiplex reverse transcriptase-polymerase chain reaction (MRP). During a 5.5-year period, 442 diagnostic acute leukemia specimens were submitted for MRP-based detection of 7 common recurrent translocations: t(8;21), t(15;17), inv(16), t(9;22), t(12;21), t(4;11), and t(1;19), with a detection rate of 15.2% (67/442). CC was performed in 330 (74.7%) of 442 cases. In 7 of these 330 cases, CC missed the translocation detected by MRP. In 50 additional cases, CC revealed 1 of the MRP-detectable translocations (all were also MRP positive), yielding a false-negative rate of 12% (7/57) for the CC assay. The remaining 140 of 190 cases with clonal cytogenetic changes harbored abnormalities that were not targeted by the MRP assay, including 8 that define specific acute myeloid leukemia entities. This study revealed the frequent occurrence of false-negative, entity-defining CC analysis and highlighted the complementary nature of MRP and CC approaches in detecting genetic abnormalities in acute leukemia.

  13. Emotions and false memories: valence or arousal?

    Science.gov (United States)

    Corson, Yves; Verrier, Nadège

    2007-03-01

    The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.

  14. Sentinel lymph node biopsy: is it possible to reduce false negative rates by excluding patients with nodular melanoma?

    LENUS (Irish Health Repository)

    Corrigan, M A

    2012-02-03

    OBJECTIVE: The aim of this study was to review the outcome of sentinel lymph node biopsy (SLNB) in patients with melanoma and to delineate whether patients with nodular melanoma are more likely to develop nodal recurrence despite negative SLNB. METHODS: Consecutive patients with cutaneous melanoma undergoing SLNB were identified from a departmental database between 1997 and 2005. Factors including demographic data, site, histological subtype, depth and outcome were examined. RESULTS: Of 131 patients, 103 were node negative and eligible for study. The median age was 53 (16-82) years with 46 patients being male (45%) and 57 female (55%). Primary melanoma sites included lower limb (49; 48%), upper limb (29; 28%), head (12; 11%), trunk (7; 7%) and back (6; 6%). The median Breslow thickness was 2mm. Superficial spreading accounted for 43% of melanoma with nodular accounting for 42%. Median follow-up was 40 (3-90) months. Of 20 relapses, seven recurred in the same nodal basin, three were satellite recurrences, one recurred with both satellite and nodal lesions simultaneously, and nine experienced haematogenous spread. Of the eight patients who developed recurrence in the same nodal basin, four were of nodular histological subtype (p=NS). All of the three patients with satellite lesions had nodular melanoma histologically (p=0.02). When nodal and satellite recurrences were combined, eight of 11 were histologically nodular (p=0.01). CONCLUSIONS: This study indicates that lymphatic recurrence occurs more often in SLNB negative patients with nodular melanoma. Further evaluation of the inclusion criteria for sentinel node biopsy is warranted.

  15. False negative pericardial Focused Assessment with Sonography for Trauma examination following cardiac rupture from blunt thoracic trauma: a case report.

    Science.gov (United States)

    Baker, Laura; Almadani, Ammar; Ball, Chad G

    2015-07-15

    The Focused Assessment with Sonography for Trauma examination is an invaluable tool in the initial assessment of any injured patient. Although highly sensitive and accurate for identifying hemoperitoneum, occasional false negative results do occur in select scenarios. We present a previously unreported case of survival following blunt cardiac rupture with associated negative pericardial window due to a concurrent pericardial wall laceration. A healthy 46-year-old white woman presented to our level 1 trauma center with hemodynamic instability following a motor vehicle collision. Although her abdominal Focused Assessment with Sonography for Trauma windows were positive for fluid, her pericardial window was negative. After immediate transfer to the operating room in the setting of persistent instability, a subsequent thoracotomy identified a blunt cardiac rupture that was draining into the ipsilateral pleural space via an adjacent tear in the pericardium. The cardiac injury was controlled with digital pressure, resuscitation completed, and then repaired using standard cardiorrhaphy techniques. Following repair of her injuries (left ventricle, left atrial appendage, and liver), her postoperative course was uneventful. Evaluation of the pericardial space using Focused Assessment with Sonography for Trauma is an important component in the initial assessment of the severely injured patient. Even in cases of blunt mechanisms however, clinicians must be wary of occasional false negative pericardial ultrasound evaluations secondary to a concomitant pericardial laceration and subsequent decompression of hemorrhage from the cardiac rupture into the ipsilateral pleural space.

  16. [Abnormalities in cervical smears stored in plastic bags: potential cause of false negatives].

    Science.gov (United States)

    Ortega-González, Patricia; González-Bravo, Margarita S; Jiménez-Muñoz-Ledo, Gustavo; Macías, Alejandro E

    2011-01-01

    Cervical smear is the most economic and efficient diagnostic tool for the screening of cervical cancer. However, since plastic bags have been used in Guanajuato to transport and store smears, we have observed cytological abnormalities which difficult the diagnosis and lead to false negatives. To describe those abnormalities. Out of 340 women registered in a primary care center in Mexico, 68 were selected through systematic random sampling during 2007. A cervical smear was obtained and placed on two slides. The first sample was allowed to dry but the second one was placed into the plastic bag immediately after fixation. After 15 days all the smears were stained with the Papanicolaou technique. A certified pathologist, blinded about the variable of study, interpreted the samples according to the Bethesda system, and evaluated the presence of necrosis, edema, holes, and opportunistic microorganisms. Of the 68 smears exposed to a humid storage, 36 (53%) were inadequate for diagnosis (Fisher's exact probability plastic bags.

  17. Assessment method to predict the rate of unresolved false alarms

    International Nuclear Information System (INIS)

    Reardon, P.T.; Eggers, R.F.; Heaberlin, S.W.

    1982-06-01

    A method has been developed to predict the rate of unresolved false alarms of material loss in a nuclear facility. The computer program DETRES-1 was developed. The program first assigns the true values of control unit components receipts, shipments, beginning and ending inventories. A normal random number generator is used to generate measured values of each component. A loss estimator is calculated from the control unit's measured values. If the loss estimator triggers a detection alarm, a response is simulated. The response simulation is divided into two phases. The first phase is to simulate remeasurement of the components of the detection loss estimator using the same or better measurement methods or inferences from surrounding control units. If this phase of response continues to indicate a material loss, phase of response simulating a production shutdown and comprehensive cleanout is initiated. A new loss estimator is found, and tested against the alarm thresholds. If the estimator value is below the threshold, the original detection alarm is considered resolved; if above the threshold, an unresolved alarm has occurred. A tally is kept of valid alarms, unresolved false alarms, and failure to alarm upon a true loss

  18. False memories and memory confidence in borderline patients.

    Science.gov (United States)

    Schilling, Lisa; Wingenfeld, Katja; Spitzer, Carsten; Nagel, Matthias; Moritz, Steffen

    2013-12-01

    Mixed results have been obtained regarding memory in patients with borderline personality disorder (BPD). Prior reports and anecdotal evidence suggests that patients with BPD are prone to false memories but this assumption has to been put to firm empirical test, yet. Memory accuracy and confidence was assessed in 20 BPD patients and 22 healthy controls using a visual variant of the false memory (Deese-Roediger-McDermott) paradigm which involved a negative and a positive-valenced picture. Groups did not differ regarding veridical item recognition. Importantly, patients did not display more false memories than controls. At trend level, borderline patients rated more items as new with high confidence compared to healthy controls. The results tentatively suggest that borderline patients show uncompromised visual memory functions and display no increased susceptibility for distorted memories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening

    Science.gov (United States)

    Weinstein, Susan P.; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Digital breast tomosynthesis (DBT) represents a valuable addition to breast cancer screening by decreasing recall rates while increasing cancer detection rates. The increased accuracy achieved with DBT is due to the quasi–three-dimensional format of the reconstructed images and the ability to “scroll through” breast tissue in the reconstructed images, thereby reducing the effect of tissue superimposition found with conventional planar digital mammography. The margins of both benign and malignant lesions are more conspicuous at DBT, which allows improved lesion characterization, increased reader confidence, and improved screening outcomes. However, even with the improvements in accuracy achieved with DBT, there remain differences in breast cancer conspicuity by mammographic view. Early data suggest that breast cancers may be more conspicuous on craniocaudal (CC) views than on mediolateral oblique (MLO) views. While some very laterally located breast cancers may be visualized on only the MLO view, the increased conspicuity of cancers on the CC view compared with the MLO view suggests that DBT screening should be performed with two-view imaging. Even with the improved conspicuity of lesions at DBT, there may still be false-negative studies. Subtle lesions seen on only one view may be discounted, and dense and/or complex tissue patterns may make some cancers occult or extremely difficult to detect. Therefore, radiologists should be cognizant of both perceptual and cognitive errors to avoid potential pitfalls in lesion detection and characterization. ©RSNA, 2016 Online supplemental material is available for this article. PMID:27715711

  20. On the susceptibility of adaptive memory to false memory illusions.

    Science.gov (United States)

    Howe, Mark L; Derbish, Mary H

    2010-05-01

    Previous research has shown that survival-related processing of word lists enhances retention for that material. However, the claim that survival-related memories are more accurate has only been examined when true recall and recognition of neutral material has been measured. In the current experiments, we examined the adaptive memory superiority effect for different types of processing and material, measuring accuracy more directly by comparing true and false recollection rates. Survival-related information and processing was examined using word lists containing backward associates of neutral, negative, and survival-related critical lures and type of processing (pleasantness, moving, survival) was varied using an incidental memory paradigm. Across four experiments, results showed that survival-related words were more susceptible than negative and neutral words to the false memory illusion and that processing information in terms of its relevance to survival independently increased this susceptibility to the false memory illusion. Overall, although survival-related processing and survival-related information resulted in poorer, not more accurate, memory, such inaccuracies may have adaptive significance. These findings are discussed in the context of false memory research and recent theories concerning the importance of survival processing and the nature of adaptive memory. Copyright 2009 Elsevier B.V. All rights reserved.

  1. Discrete emotion-congruent false memories in the DRM paradigm.

    Science.gov (United States)

    Bland, Cassandra E; Howe, Mark L; Knott, Lauren

    2016-08-01

    Research has shown that false-memory production is enhanced for material that is emotionally congruent with the mood of the participant at the time of encoding. So far this research has only been conducted to examine the influence of generic negative affective mood states and generic negative stimuli on false-memory production. In addition, much of the research is limited as it focuses on valence and arousal dimensions, and fails to take into account the more comprehensive nature of emotions. The current study demonstrates that this effect goes beyond general negative or positive moods and acts at a more discrete emotional level. Participants underwent a standard emotion-induction procedure before listening to negative emotional or neutral associative word lists. The emotions induced, negative word lists, and associated nonpresented critical lures, were related to either fear or anger, 2 negative valence emotions that are also both high in arousal. Results showed that when valence and arousal are controlled for, false memories are more likely to be produced for discrete emotionally congruent compared with incongruent materials. These results support spreading activation theories of false remembering and add to our understanding of the adaptive nature of false-memory production. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  2. The Introduction of Adult Appendicitis Score Reduced Negative Appendectomy Rate.

    Science.gov (United States)

    Sammalkorpi, H E; Mentula, P; Savolainen, H; Leppäniemi, A

    2017-09-01

    Implementation of a clinical risk score into diagnostics of acute appendicitis may provide accurate diagnosis with selective use of imaging studies. The aim of this study was to prospectively validate recently described diagnostic scoring system, Adult Appendicitis Score, and evaluate its effects on negative appendectomy rate. Adult Appendicitis Score stratifies patients into three groups: high, intermediate, and low risk of appendicitis. The score was implemented in diagnostics of adult patients suspected of acute appendicitis in two university hospitals. We analyzed the effects of Adult Appendicitis Score on diagnostic accuracy, imaging studies, and treatment. The study population was compared with a reference population of 829 patients suspected of acute appendicitis originally enrolled for the study of construction of the Adult Appendicitis Score. This study enrolled 908 patients of whom 432 (48%) had appendicitis. The score stratified 49% of all appendicitis patients into high-risk group with specificity of 93.3%. In the low-risk group, prevalence of appendicitis was 7%. The histologically confirmed negative appendectomy rate decreased from 18.2% to 8.7%, pAppendicitis Score is a reliable tool for stratification of patients into selective imaging, which results in low negative appendectomy rate.

  3. False-Positive Rate Determination of Protein Target Discovery using a Covalent Modification- and Mass Spectrometry-Based Proteomics Platform

    Science.gov (United States)

    Strickland, Erin C.; Geer, M. Ariel; Hong, Jiyong; Fitzgerald, Michael C.

    2014-01-01

    Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2 % and analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.

  4. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  5. Controlling the local false discovery rate in the adaptive Lasso

    KAUST Repository

    Sampson, J. N.

    2013-04-09

    The Lasso shrinkage procedure achieved its popularity, in part, by its tendency to shrink estimated coefficients to zero, and its ability to serve as a variable selection procedure. Using data-adaptive weights, the adaptive Lasso modified the original procedure to increase the penalty terms for those variables estimated to be less important by ordinary least squares. Although this modified procedure attained the oracle properties, the resulting models tend to include a large number of "false positives" in practice. Here, we adapt the concept of local false discovery rates (lFDRs) so that it applies to the sequence, λn, of smoothing parameters for the adaptive Lasso. We define the lFDR for a given λn to be the probability that the variable added to the model by decreasing λn to λn-δ is not associated with the outcome, where δ is a small value. We derive the relationship between the lFDR and λn, show lFDR =1 for traditional smoothing parameters, and show how to select λn so as to achieve a desired lFDR. We compare the smoothing parameters chosen to achieve a specified lFDR and those chosen to achieve the oracle properties, as well as their resulting estimates for model coefficients, with both simulation and an example from a genetic study of prostate specific antigen.

  6. High estradiol levels improve false memory rates and meta-memory in highly schizotypal women.

    Science.gov (United States)

    Hodgetts, Sophie; Hausmann, Markus; Weis, Susanne

    2015-10-30

    Overconfidence in false memories is often found in patients with schizophrenia and healthy participants with high levels of schizotypy, indicating an impairment of meta-cognition within the memory domain. In general, cognitive control is suggested to be modulated by natural fluctuations in oestrogen. However, whether oestrogen exerts beneficial effects on meta-memory has not yet been investigated. The present study sought to provide evidence that high levels of schizotypy are associated with increased false memory rates and overconfidence in false memories, and that these processes may be modulated by natural differences in estradiol levels. Using the Deese-Roediger-McDermott paradigm, it was found that highly schizotypal participants with high estradiol produced significantly fewer false memories than those with low estradiol. No such difference was found within the low schizotypy participants. Highly schizotypal participants with high estradiol were also less confident in their false memories than those with low estradiol; low schizotypy participants with high estradiol were more confident. However, these differences only approached significance. These findings suggest that the beneficial effect of estradiol on memory and meta-memory observed in healthy participants is specific to highly schizotypal individuals and might be related to individual differences in baseline dopaminergic activity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Surrogate obesity negatively impacts pregnancy rates in third-party reproduction.

    Science.gov (United States)

    DeUgarte, Daniel A; DeUgarte, Catherine M; Sahakian, Vicken

    2010-02-01

    In a retrospective cohort review of third-party reproduction, we observed that surrogate body mass index (BMI) negatively impacts implantation rates in oocyte-donor in vitro fertilization cycles. A BMI > or =35 kg/m(2) cutoff is associated with a statistically significant decrease in pregnancy rates but not miscarriage rates. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Influence of negative interest rates on endowements and foundations functioning

    Directory of Open Access Journals (Sweden)

    Nikolić Dušan Ž.

    2015-01-01

    Full Text Available Negative interest rate exists in the case when on the basis of the deposit contract a deponent is obliged to pay to a depository (a bank a reimbursement for the money keeping (paying to save. The scientific literature indicates that the legal regulation on endowments and foundations in a vast number of countries is based on the presumption that interest rates cannot be negative and that we are encountering the phenomenon of which we have limited knowledge. The introduction of negative interest rates, thus, could endanger the functioning, if not the subsistence of some endowments and foundations. The vulnerable social groups could, thereby, be especially affected. The Law on Endowments and Foundations of the Republic of Serbia enshrines that the endowments' capital shall not fall under the minimum capital assets of30.000 EUR recalculated in dinars based on the middle exchange rate of the National Bank of Serbia on the day of establishment. Apart from that, a founder may in the Articles of Association determine the minimum value below which the capital assets of endowment may not be reduced, which may not be lower of the minimum assets value set by the Law. In Serbia negative interest rates could aggravate, and throughout the time, even prevent the accomplishment of aims of endowments and foundations which for the operation of their activities may use only the interest yields and not the means of capital assets above the legal minimum. Some endowments could even cease to exist due to the diminishment of their minimum capital assets which entirely consist of the money deposited in the banks. The Article indicates the need for reconsidering the legal norms currently in force and that the transformation of certain legal institutes shall timely commence, whereby their systematic and social functions shall be regarded, as well as the need for introducing a streamlined corrective mechanisms with the aim of protecting interests of the weaker party in

  9. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    Directory of Open Access Journals (Sweden)

    Emerence Crompot

    Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  10. Specificity control for read alignments using an artificial reference genome-guided false discovery rate.

    Science.gov (United States)

    Giese, Sven H; Zickmann, Franziska; Renard, Bernhard Y

    2014-01-01

    Accurate estimation, comparison and evaluation of read mapping error rates is a crucial step in the processing of next-generation sequencing data, as further analysis steps and interpretation assume the correctness of the mapping results. Current approaches are either focused on sensitivity estimation and thereby disregard specificity or are based on read simulations. Although continuously improving, read simulations are still prone to introduce a bias into the mapping error quantitation and cannot capture all characteristics of an individual dataset. We introduce ARDEN (artificial reference driven estimation of false positives in next-generation sequencing data), a novel benchmark method that estimates error rates of read mappers based on real experimental reads, using an additionally generated artificial reference genome. It allows a dataset-specific computation of error rates and the construction of a receiver operating characteristic curve. Thereby, it can be used for optimization of parameters for read mappers, selection of read mappers for a specific problem or for filtering alignments based on quality estimation. The use of ARDEN is demonstrated in a general read mapper comparison, a parameter optimization for one read mapper and an application example in single-nucleotide polymorphism discovery with a significant reduction in the number of false positive identifications. The ARDEN source code is freely available at http://sourceforge.net/projects/arden/.

  11. Estimation of adjusted rate differences using additive negative binomial regression.

    Science.gov (United States)

    Donoghoe, Mark W; Marschner, Ian C

    2016-08-15

    Rate differences are an important effect measure in biostatistics and provide an alternative perspective to rate ratios. When the data are event counts observed during an exposure period, adjusted rate differences may be estimated using an identity-link Poisson generalised linear model, also known as additive Poisson regression. A problem with this approach is that the assumption of equality of mean and variance rarely holds in real data, which often show overdispersion. An additive negative binomial model is the natural alternative to account for this; however, standard model-fitting methods are often unable to cope with the constrained parameter space arising from the non-negativity restrictions of the additive model. In this paper, we propose a novel solution to this problem using a variant of the expectation-conditional maximisation-either algorithm. Our method provides a reliable way to fit an additive negative binomial regression model and also permits flexible generalisations using semi-parametric regression functions. We illustrate the method using a placebo-controlled clinical trial of fenofibrate treatment in patients with type II diabetes, where the outcome is the number of laser therapy courses administered to treat diabetic retinopathy. An R package is available that implements the proposed method. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Case-positive versus case-negative designs for low-rate lithium thionyl chloride cells

    Science.gov (United States)

    Mahy, T. X.

    1982-03-01

    Case polarity design choices are discussed. Two examples of case-negative designs are presented. One battery is thionyl chloride limited and the other is lithium limited. The case-positive design is thionyl chloride limited. It is found that the case-positive/case-negative design consideration does not seem to have much bearing on storage. However, during low rate discharge, the case-negative cells show a steadily decreasing capacity as you go to lower and lower rates.

  13. False Memories for Affective Information in Schizophrenia.

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p  false memories ( p  > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  14. False Memories for Affective Information in Schizophrenia

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600

  15. Mood-congruent false memories persist over time

    OpenAIRE

    Knott, L.; Thorley, C.

    2014-01-01

    In this study we examined the role of mood-congruency and retention interval on the false recognition of emotion laden items using the Deese/Roediger-McDermott (DRM) paradigm. Previous research has shown a mood-congruent false memory enhancement during immediate recognition tasks. The present study examined the persistence of this effect following a one-week delay. Participants were placed in a negative or neutral mood, presented with negative-emotion and neutral-emotion DRM word lists, and a...

  16. Rate and predictors of negative effects of psychotherapy in psychiatric and psychosomatic inpatients.

    Science.gov (United States)

    Rheker, Julia; Beisel, Sylvia; Kräling, Svenja; Rief, Winfried

    2017-08-01

    Studies examining the rates of negative effects of psychotherapy are rare and the reported rates differ widely. To be able to calculate adequate benefit-cost ratios in conjunction with different samples and settings, we need a deeper understanding of these effects. We therefore investigated whether different treatment settings would reveal varying rates and kinds of negative effects by recruiting patients from a psychiatric (n=93) and a psychosomatic rehabilitation (n=63) hospital. Negative effects of psychotherapy were assessed with the Inventory for the Assessment of Negative Effects of Psychotherapy post-treatment. To investigate whether patients' pre-treatment expectations have an influence on reported negative effects, patients filled in the Patient Questionnaire on Therapy Expectation and Evaluation prior to treatment begin. Patients from the psychiatric hospital reported an average 1.41 negative effects, with 58.7% reporting at least one negative effect. Those from the psychosomatic hospital reported 0.76 negative effects on average, with 45.2% of patients reporting at least one negative effect. The differences between these samples are significant. The two samples' top three reported types of negative effects are that patients had experienced more downs during or just before the end of the therapy, that patients had difficulty making important decisions without the therapist, and that patients were concerned that colleagues or friends might find out about the therapy. A regression analysis revealed that the clinical setting (psychosomatic rehabilitation hospital vs. psychiatric hospital) and expectations in the form of hope of improvement were significant predictors for negative effects of psychotherapy. Our study highlights the need to examine the negative effects of psychotherapy in different settings and samples to better evaluate the benefit-cost ratios of treatments for different patient groups. It also shows that we need guidelines for assessing and

  17. Expert System Constant False Alarm Rate (CFAR) Processor

    National Research Council Canada - National Science Library

    Wicks, Michael C

    2006-01-01

    An artificial intelligence system improves radar signal processor performance by increasing target probability of detection and reducing probability of false alarm in a severe radar clutter environment...

  18. Mood-congruent false memories persist over time.

    Science.gov (United States)

    Knott, Lauren M; Thorley, Craig

    2014-01-01

    In this study, we examined the role of mood-congruency and retention interval on the false recognition of emotion laden items using the Deese/Roediger-McDermott (DRM) paradigm. Previous research has shown a mood-congruent false memory enhancement during immediate recognition tasks. The present study examined the persistence of this effect following a one-week delay. Participants were placed in a negative or neutral mood, presented with negative-emotion and neutral-emotion DRM word lists, and administered with both immediate and delayed recognition tests. Results showed that a negative mood state increased remember judgments for negative-emotion critical lures, in comparison to neutral-emotion critical lures, on both immediate and delayed testing. These findings are discussed in relation to theories of spreading activation and emotion-enhanced memory, with consideration of the applied forensic implications of such findings.

  19. The negativity bias predicts response rate to Behavioral Activation for depression.

    Science.gov (United States)

    Gollan, Jackie K; Hoxha, Denada; Hunnicutt-Ferguson, Kallio; Norris, Catherine J; Rosebrock, Laina; Sankin, Lindsey; Cacioppo, John

    2016-09-01

    This treatment study investigated the extent to which asymmetric dimensions of affective responding, specifically the positivity offset and the negativity bias, at pretreatment altered the rate of response to Behavioral Activation treatment for depression. Forty-one depressed participants were enrolled into 16 weekly sessions of BA. An additional 36 lifetime healthy participants were evaluated prospectively for 16 weeks to compare affective responding between healthy and remitted patients at post-treatment. All participants were assessed at Weeks 0, 8 and 16 using repeated measures, involving a structured clinical interview for DSM-IV Axis I disorders, questionnaires, and a computerized task designed to measure affective responses to unpleasant, neutral, and pleasant images. The negativity bias at pre-treatment predicted the rate of response to BA, while the positivity offset did not. Only one treatment condition was used in this study and untreated depressed participants were not enrolled, limiting our ability to compare the effect of BA. Baseline negativity bias may serve as a signal for patients to engage in and benefit from the goal-directed BA strategies, thereby accelerating rate of response. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Effects of false feedback on affect, cognition, behavior, and postevent processing: the mediating role of self-focused attention.

    Science.gov (United States)

    Makkar, Steve R; Grisham, Jessica R

    2013-03-01

    Current social phobia models (e.g., Clark & Wells, 1995; Leary & Kowalski, 1995) postulate that socially anxious individuals negatively appraise their anxiety sensations (e.g., sweating, heart racing, blushing) as evidence of poor social performance, and thus fear these anxiety symptoms will be noticed and judged negatively by others. Consequently, they become self-focused and hypervigilant of these sensations and use them to judge how they appear to others. To test this model, high (N=41) and low (N=38) socially anxious participants were shown false physiological feedback regarding an increase or decrease in heart rate prior to and during an impromptu speech task. Relative to participants who observed a false heart rate decrease, those in the increase condition reported higher levels of negative affect, more negative performance appraisals, and more frequent negative ruminative thoughts, and these effects were mediated by an increase in self-focused attention. The unhelpful effects of the physiological feedback were not specific to high socially anxious participants. The results have implications for current cognitive models as well as the treatment of social phobia. Copyright © 2012. Published by Elsevier Ltd.

  1. Validation of the Peripheral Ultrasound-guided Vascular Access Rating Scale

    DEFF Research Database (Denmark)

    Primdahl, Stine C.; Weile, Jesper; Clemmesen, Louise

    2018-01-01

    rating scale (P =.029, one-way ANOVA), and the P-UGVA rating scale scores also correlated strongly with the overall performance evaluations (rho=0.87, PPearson correlation). We calculated a pass/fail score of 29, which lead to a theoretical false positive rate of 26.5% and false negative rate of 8...

  2. Clinical Significance of CK19 Negative Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fujisue, Mamiko, E-mail: nishimura.reiki@cityhosp-kumamoto.jp; Nishimura, Reiki; Okumura, Yasuhiro [Department of Breast and Endocrine Surgery, Kumamoto City Hospital, 1-1-60 Kotoh, Kumamoto City, Kumamoto 862-8505 (Japan); Tashima, Rumiko [Department of Surgery, Kumamoto City Hospital, 1-1-60 Kotoh, Kumamoto City, Kumamoto 862-8505 (Japan); Nishiyama, Yasuyuki; Osako, Tomofumi [Department of Breast and Endocrine Surgery, Kumamoto City Hospital, 1-1-60 Kotoh, Kumamoto City, Kumamoto 862-8505 (Japan); Toyozumi, Yasuo; Arima, Nobuyuki [Department of Pathology, Kumamoto City Hospital, 1-1-60 Kotoh, Kumamoto City, Kumamoto 862-8505 (Japan)

    2012-12-21

    Analysis of sentinel lymph nodes (SLNs) by means of One-Step Nucleic Acid Amplification (OSNA) is gaining widespread use as a quick and accurate method. This assay detects the expression level of cytokeratin 19 (CK19) which is present in some but not all breast tumors. In this study, the clinical significance of negative CK19 was investigated in 219 cases of primary breast cancer. In 179 patients with clinically negative nodes, OSNA and imprint smear cytology of SLN were performed simultaneously. The OSNA revealed a node-positive rate of 24.6%. Negative CK19 correlated significantly with negative ER/PgR and higher Ki-67 values, and marginally with higher nuclear grade and p53 overexpression. The triple negative subtype showed lower CK19 expression. OSNA revealed that one of the negative CK19 cases was actually a false negative but this was corrected with the use of the imprint smear cytology. In conclusion, CK19 negativity reflected the aggressiveness of primary breast cancer. OSNA assay used to analyze SLN was useful, but there is a possibility that it will mistakenly detect false negatives in CK19 negative tumors. Therefore, in tumors with negative CK19, the imprint smear cytology may be more useful in cases with macrometastasis.

  3. Clinical Significance of CK19 Negative Breast Cancer

    Directory of Open Access Journals (Sweden)

    Nobuyuki Arima

    2012-12-01

    Full Text Available Analysis of sentinel lymph nodes (SLNs by means of One-Step Nucleic Acid Amplification (OSNA is gaining widespread use as a quick and accurate method. This assay detects the expression level of cytokeratin 19 (CK19 which is present in some but not all breast tumors. In this study, the clinical significance of negative CK19 was investigated in 219 cases of primary breast cancer. In 179 patients with clinically negative nodes, OSNA and imprint smear cytology of SLN were performed simultaneously. The OSNA revealed a node-positive rate of 24.6%. Negative CK19 correlated significantly with negative ER/PgR and higher Ki-67 values, and marginally with higher nuclear grade and p53 overexpression. The triple negative subtype showed lower CK19 expression. OSNA revealed that one of the negative CK19 cases was actually a false negative but this was corrected with the use of the imprint smear cytology. In conclusion, CK19 negativity reflected the aggressiveness of primary breast cancer. OSNA assay used to analyze SLN was useful, but there is a possibility that it will mistakenly detect false negatives in CK19 negative tumors. Therefore, in tumors with negative CK19, the imprint smear cytology may be more useful in cases with macrometastasis.

  4. Clinical Significance of CK19 Negative Breast Cancer

    International Nuclear Information System (INIS)

    Fujisue, Mamiko; Nishimura, Reiki; Okumura, Yasuhiro; Tashima, Rumiko; Nishiyama, Yasuyuki; Osako, Tomofumi; Toyozumi, Yasuo; Arima, Nobuyuki

    2012-01-01

    Analysis of sentinel lymph nodes (SLNs) by means of One-Step Nucleic Acid Amplification (OSNA) is gaining widespread use as a quick and accurate method. This assay detects the expression level of cytokeratin 19 (CK19) which is present in some but not all breast tumors. In this study, the clinical significance of negative CK19 was investigated in 219 cases of primary breast cancer. In 179 patients with clinically negative nodes, OSNA and imprint smear cytology of SLN were performed simultaneously. The OSNA revealed a node-positive rate of 24.6%. Negative CK19 correlated significantly with negative ER/PgR and higher Ki-67 values, and marginally with higher nuclear grade and p53 overexpression. The triple negative subtype showed lower CK19 expression. OSNA revealed that one of the negative CK19 cases was actually a false negative but this was corrected with the use of the imprint smear cytology. In conclusion, CK19 negativity reflected the aggressiveness of primary breast cancer. OSNA assay used to analyze SLN was useful, but there is a possibility that it will mistakenly detect false negatives in CK19 negative tumors. Therefore, in tumors with negative CK19, the imprint smear cytology may be more useful in cases with macrometastasis

  5. False memories for affective information in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Beth Fairfield

    2016-11-01

    Full Text Available Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the-to-be-remembered material and false memory occurrence has not yet been studied. In this study, twenty-four patients and twenty-four healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p0.05 resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e. neutral episodes yielded a higher degree of errors than positive and negative episodes. Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  6. Valence and the development of immediate and long-term false memory illusions.

    Science.gov (United States)

    Howe, Mark L; Candel, Ingrid; Otgaar, Henry; Malone, Catherine; Wimmer, Marina C

    2010-01-01

    Across five experiments we examined the role of valence in children's and adults' true and false memories. Using the Deese/Roediger-McDermott paradigm and either neutral or negative-emotional lists, both adults' (Experiment 1) and children's (Experiment 2) true recall and recognition was better for neutral than negative items, and although false recall was also higher for neutral items, false recognition was higher for negative items. The last three experiments examined adults' (Experiment 3) and children's (Experiments 4 and 5) 1-week long-term recognition of neutral and negative-emotional information. The results replicated the immediate recall and recognition findings from the first two experiments. More important, these experiments showed that although true recognition decreased over the 1-week interval, false recognition of neutral items remained unchanged whereas false recognition of negative-emotional items increased. These findings are discussed in terms of theories of emotion and memory as well as their forensic implications.

  7. Emotion and false memory: The context-content paradox.

    Science.gov (United States)

    Bookbinder, S H; Brainerd, C J

    2016-12-01

    False memories are influenced by a variety of factors, but emotion is a variable of special significance, for theoretical and practical reasons. Interestingly, emotion's effects on false memory depend on whether it is embedded in the content of to-be-remembered events or in our moods, where mood is an aspect of the context in which events are encoded. We sketch the theoretical basis for this content-context dissociation and then review accumulated evidence that content and context effects are indeed different. Paradoxically, we find that in experiments on spontaneous and implanted false memories, negatively valenced content foments distortion, but negatively valenced moods protect against it. In addition, correlational data show that enduring negative natural moods (e.g., depression) foment false memory. Current opponent-process models of false memory, such as fuzzy-trace theory, are able to explain the content-context dissociation: Variations in emotional content primarily affect memory for the gist of events, whereas variations in emotional context primarily affect memory for events' exact verbatim form. Important questions remain about how these effects are modulated by variations in memory tests and in arousal. Promising methods of tackling those questions are outlined, especially designs that separate the gist and verbatim influences of emotion. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  8. The effectiveness of Japan's negative interest rate policy

    OpenAIRE

    Yoshino, Naoyuki; Taghizadeh-Hesary, Farhad; Miyamoto, Hiroaki

    2017-01-01

    In April 2013, the Bank of Japan (BOJ) introduced an inflation target of 2% with the aim of overcoming deflation and achieving sustainable economic growth. But due to lower international oil prices, it was unable to achieve this target and was forced to take further measures. Hence, in February 2016, the BOJ adopted a negative interest rate policy by massively increasing the money supply through purchasing long-term Japanese government bonds (JGB). The BOJ had previously purchased short-term ...

  9. Utilization of negative beat-frequencies for maximizing the update-rate of OFDR

    Science.gov (United States)

    Gabai, Haniel; Botsev, Yakov; Hahami, Meir; Eyal, Avishay

    2015-07-01

    In traditional OFDR systems, the backscattered profile of a sensing fiber is inefficiently duplicated to the negative band of spectrum. In this work, we present a new OFDR design and algorithm that remove this redundancy and make use of negative beat frequencies. In contrary to conventional OFDR designs, it facilitates efficient use of the available system bandwidth and enables distributed sensing with the maximum allowable interrogation update-rate for a given fiber length. To enable the reconstruction of negative beat frequencies an I/Q type receiver is used. In this receiver, both the in-phase (I) and quadrature (Q) components of the backscatter field are detected. Following detection, both components are digitally combined to produce a complex backscatter signal. Accordingly, due to its asymmetric nature, the produced spectrum will not be corrupted by the appearance of negative beat-frequencies. Here, via a comprehensive computer simulation, we show that in contrast to conventional OFDR systems, I/Q OFDR can be operated at maximum interrogation update-rate for a given fiber length. In addition, we experimentally demonstrate, for the first time, the ability of I/Q OFDR to utilize negative beat-frequencies for long-range distributed sensing.

  10. A low false negative filter for detecting rare bird species from short video segments using a probable observation data set-based EKF method.

    Science.gov (United States)

    Song, Dezhen; Xu, Yiliang

    2010-09-01

    We report a new filter to assist the search for rare bird species. Since a rare bird only appears in front of a camera with very low occurrence (e.g., less than ten times per year) for very short duration (e.g., less than a fraction of a second), our algorithm must have a very low false negative rate. We verify the bird body axis information with the known bird flying dynamics from the short video segment. Since a regular extended Kalman filter (EKF) cannot converge due to high measurement error and limited data, we develop a novel probable observation data set (PODS)-based EKF method. The new PODS-EKF searches the measurement error range for all probable observation data that ensures the convergence of the corresponding EKF in short time frame. The algorithm has been extensively tested using both simulated inputs and real video data of four representative bird species. In the physical experiments, our algorithm has been tested on rock pigeons and red-tailed hawks with 119 motion sequences. The area under the ROC curve is 95.0%. During the one-year search of ivory-billed woodpeckers, the system reduces the raw video data of 29.41 TB to only 146.7 MB (reduction rate 99.9995%).

  11. High confidence in falsely recognizing prototypical faces.

    Science.gov (United States)

    Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen

    2018-06-01

    We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.

  12. Age Differences in the Rejection of False Memories: The Effects of Giving Warning Instructions and Slowing the Presentation Rate

    Science.gov (United States)

    Carneiro, Paula; Fernandez, Angel

    2010-01-01

    Two experiments were conducted to examine whether children of different ages differ in their ability to reject associative false memories with the Deese-Roediger-McDermott (DRM) paradigm. Two different types of manipulations that are thought to facilitate false memory rejection in adults--slowing the presentation rate and issuing explicit…

  13. False Negatives for Remote Life Detection on Ocean-Bearing Planets: Lessons from the Early Earth.

    Science.gov (United States)

    Reinhard, Christopher T; Olson, Stephanie L; Schwieterman, Edward W; Lyons, Timothy W

    2017-04-01

    Ocean-atmosphere chemistry on Earth has undergone dramatic evolutionary changes throughout its long history, with potentially significant ramifications for the emergence and long-term stability of atmospheric biosignatures. Though a great deal of work has centered on refining our understanding of false positives for remote life detection, much less attention has been paid to the possibility of false negatives, that is, cryptic biospheres that are widespread and active on a planet's surface but are ultimately undetectable or difficult to detect in the composition of a planet's atmosphere. Here, we summarize recent developments from geochemical proxy records and Earth system models that provide insight into the long-term evolution of the most readily detectable potential biosignature gases on Earth-oxygen (O 2 ), ozone (O 3 ), and methane (CH 4 ). We suggest that the canonical O 2 -CH 4 disequilibrium biosignature would perhaps have been challenging to detect remotely during Earth's ∼4.5-billion-year history and that in general atmospheric O 2 /O 3 levels have been a poor proxy for the presence of Earth's biosphere for all but the last ∼500 million years. We further suggest that detecting atmospheric CH 4 would have been problematic for most of the last ∼2.5 billion years of Earth's history. More broadly, we stress that internal oceanic recycling of biosignature gases will often render surface biospheres on ocean-bearing silicate worlds cryptic, with the implication that the planets most conducive to the development and maintenance of a pervasive biosphere will often be challenging to characterize via conventional atmospheric biosignatures. Key Words: Biosignatures-Oxygen-Methane-Ozone-Exoplanets-Planetary habitability. Astrobiology 17, 287-297.

  14. Endogenous Pain Modulation: Association with Resting Heart Rate Variability and Negative Affectivity.

    Science.gov (United States)

    Van Den Houte, Maaike; Van Oudenhove, Lukas; Bogaerts, Katleen; Van Diest, Ilse; Van den Bergh, Omer

    2017-07-21

    Several chronic pain syndromes are characterized by deficient endogenous pain modulation as well as elevated negative affectivity and reduced resting heart rate variability. In order to elucidate the relationships between these characteristics, we investigated whether negative affectivity and heart rate variability are associated with endogenous pain modulation in a healthy population. An offset analgesia paradigm with noxious thermal stimulation calibrated to the individual's pain threshold was used to measure endogenous pain modulation magnitude in 63 healthy individuals. Pain ratings during constant noxious heat stimulation to the arm (15 seconds) were compared with ratings during noxious stimulation comprising a 1 °C rise and return of temperature to the initial level (offset trials, 15 seconds). Offset analgesia was defined as the reduction in pain following the 1 °C decrease relative to pain at the same time point during continuous heat stimulation. Evidence for an offset analgesia effect could only be found when noxious stimulation intensity (and, hence, the individual's pain threshold) was intermediate (46 °C or 47 °C). Offset analgesia magnitude was also moderated by resting heart rate variability: a small but significant offset effect was found in participants with high but not low heart rate variability. Negative affectivity was not related to offset analgesia magnitude. These results indicate that resting heart rate variability (HRV) is related to endogenous pain modulation (EPM) in a healthy population. Future research should focus on clarifying the causal relationship between HRV and EPM and chronic pain by using longitudinal study designs. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  15. Too Good to be False : Nonsignificant Results Revisited

    NARCIS (Netherlands)

    Hartgerink, Chris H J; Wicherts, Jelte M.; Van Assen, M. A. L. M.

    2017-01-01

    Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST) is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant

  16. The False Memory and the Mirror Effects: The Role of Familiarity and Backward Association in Creating False Recollections

    Science.gov (United States)

    Anaki, D.; Faran, Y.; Ben-Shalom, D.; Henik, A.

    2005-01-01

    The mirror effect refers to a phenomenon where the hit rate is higher for low frequency words while the false alarm rate is higher for high frequency distractors. Using a false memory paradigm (Roediger & McDermott, 1995), we examined whether false memory for non-presented lures would be influenced by the lure's familiarity. The results revealed…

  17. True photographs and false memories.

    Science.gov (United States)

    Lindsay, D Stephen; Hagen, Lisa; Read, J Don; Wade, Kimberley A; Garry, Maryanne

    2004-03-01

    Some trauma-memory-oriented psychotherapists advise clients to review old family photo albums to cue suspected "repressed" memories of childhood sexual abuse. Old photos might cue long-forgotten memories, but when combined with other suggestive influences they might also contribute to false memories. We asked 45 undergraduates to work at remembering three school-related childhood events (two true events provided by parents and one pseudoevent). By random assignment, 23 subjects were also given their school classes' group photos from the years of the to-be-recalled events as memory cues. As predicted, the rate of false-memory reports was dramatically higher in the photo condition than in the no-photo condition. Indeed, the rate of false-memory reports in the photo condition was substantially higher than the rate in any previously published study.

  18. Specific absorption rate analysis of broadband mobile antenna with negative index metamaterial

    Science.gov (United States)

    Alam, Touhidul; Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul

    2016-03-01

    This paper presents a negative index metamaterial-inspired printed mobile wireless antenna that can support most mobile applications such as GSM, UMTS, Bluetooth and WLAN frequency bands. The antenna consists of a semi-circular patch, a 50Ω microstrip feed line and metamaterial ground plane. The antenna occupies a very small space of 37 × 47 × 0.508 mm3, making it suitable for mobile wireless application. The perceptible novelty shown in this proposed antenna is that reduction of specific absorption rate using the negative index metamaterial ground plane. The proposed antenna reduced 72.11 and 75.53 % of specific absorption rate at 1.8 and 2.4 GHz, respectively.

  19. Semantic processes leading to true and false memory formation in schizophrenia.

    Science.gov (United States)

    Paz-Alonso, Pedro M; Ghetti, Simona; Ramsay, Ian; Solomon, Marjorie; Yoon, Jong; Carter, Cameron S; Ragland, J Daniel

    2013-07-01

    Encoding semantic relationships between items on word lists (semantic processing) enhances true memories, but also increases memory distortions. Episodic memory impairments in schizophrenia (SZ) are strongly driven by failures to process semantic relations, but the exact nature of these relational semantic processing deficits is not well understood. Here, we used a false memory paradigm to investigate the impact of implicit and explicit semantic processing manipulations on episodic memory in SZ. Thirty SZ and 30 demographically matched healthy controls (HC) studied Deese/Roediger-McDermott (DRM) lists of semantically associated words. Half of the lists had strong implicit semantic associations and the remainder had low strength associations. Similarly, half of the lists were presented under "standard" instructions and the other half under explicit "relational processing" instructions. After study, participants performed recall and old/new recognition tests composed of targets, critical lures, and unrelated lures. HC exhibited higher true memories and better discriminability between true and false memory compared to SZ. High, versus low, associative strength increased false memory rates in both groups. However, explicit "relational processing" instructions positively improved true memory rates only in HC. Finally, true and false memory rates were associated with severity of disorganized and negative symptoms in SZ. These results suggest that reduced processing of semantic relationships during encoding in SZ may stem from an inability to implement explicit relational processing strategies rather than a fundamental deficit in the implicit activation and retrieval of word meanings from patients' semantic lexicon. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Discrete emotion-congruent false memories in the DRM paradigm

    OpenAIRE

    Bland, C.; Howe, M. L.; Knott, L.

    2016-01-01

    Research has shown that false memory production is enhanced for material that is emotionally congruent with the mood of the participant at the time of encoding. So far this research has only examined the influence of generic negative affective mood states and generic negative stimuli on false memory production. In addition, much of the research is limited as it focuses on valence and arousal dimensions, and fails to take into account the more comprehensive nature of emotions. The current stud...

  1. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    Science.gov (United States)

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  2. False Memory for Trauma-Related DRM Lists in Adolescents and Adults with Histories of Child Sexual Abuse

    Science.gov (United States)

    Goodman, Gail S.; Ogle, Christin M.; Block, Stephanie D.; Harris, LaTonya S.; Larson, Rakel P.; Augusti, Else-Marie; Cho, Young Il; Beber, Jonathan; Timmer, Susan; Urquiza, Anthony

    2014-01-01

    The purpose of the present research was to examine Deese-Roediger-McDermott (DRM) false memory for trauma-related and nontrauma-related lists in adolescents and adults with and without documented histories of child sexual abuse (CSA). Individual differences in psychopathology and adult attachment were also explored. Participants were administered free recall and recognition tests after hearing CSA, negative, neutral, and positive DRM lists. In free recall, CSA and negative lists produced the most false memory. In sharp contrast, for recognition, CSA lists enjoyed the highest d’ scores. CSA-group adolescents who evinced greater PTSD symptoms had higher rates of false memory compared to: 1) nonCSA-group adolescents with higher PTSD symptom scores (free recall), and 2) CSA-group adolescents with lower PTSD symptom scores (recognition). Regression analyses revealed that individuals with higher PTSD scores and greater fearful-avoidant attachment tendencies showed less proficient memory monitoring for CSA lists. Implications for trauma and memory development and for translational research are discussed. PMID:23786687

  3. The Relations Between False Positive and Negative Screens and Smoking Cessation and Relapse in the National Lung Screening Trial: Implications for Public Health.

    Science.gov (United States)

    Clark, Melissa A; Gorelick, Jeremy J; Sicks, JoRean D; Park, Elyse R; Graham, Amanda L; Abrams, David B; Gareen, Ilana F

    2016-01-01

    Lung screening is an opportunity for smoking cessation and relapse prevention, but smoking behaviors may differ across screening results. Changes in smoking were evaluated among 18 840 current and former smokers aged 55-74 scheduled to receive three annual lung screenings. Participants were randomized to low-dose computed tomography or single-view chest radiography in the American College of Radiology/National Lung Screening Trial. Outcome measures included point and sustained (6-month) abstinence and motivation to quit among smokers; and relapse among smokers who quit during follow-up, recent quitters (quit < 6 months), and long-term former smokers (quit ≥ 6 months). During five years of follow-up, annual point prevalence quit rates ranged from 11.6%-13.4%; 48% of current smokers reported a quit attempt and 7% of long-term former smokers relapsed. Any false positive screening result was associated with subsequent increased point (multivariable hazard ratio HR = 1.23, 95% CI = 1.13, 1.35) and sustained (HR = 1.28, 95% CI = 1.15, 1.43) abstinence among smokers. Recent quitters with ≥1 false positive screen were less likely to relapse (HR = 0.72, 95% CI = 0.54, 0.96). Screening result was not associated with relapse among long-term former smokers or among baseline smokers who quit during follow-up. A false positive screen was associated with increased smoking cessation and less relapse among recent quitters. Consistently negative screens were not associated with greater relapse among long-term former smokers. Given the Affordable Care Act requires most health plans to cover smoking cessation and lung screening, the impact and cost-effectiveness of lung screening could be further enhanced with the addition of smoking cessation interventions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Measurement and numerical simulation of a small centrifugal compressor characteristics at small or negative flow rate

    Science.gov (United States)

    Tsukamoto, Kaname; Okada, Mizuki; Inokuchi, Yuzo; Yamasaki, Nobuhiko; Yamagata, Akihiro

    2017-04-01

    For centrifugal compressors used in automotive turbochargers, the extension of the surge margin is demanded because of lower engine speed. In order to estimate the surge line exactly, it is required to acquire the compressor characteristics at small or negative flow rate. In this paper, measurement and numerical simulation of the characteristics at small or negative flow rate are carried out. In the measurement, an experimental facility with a valve immediately downstream of the compressor is used to suppress the surge. In the numerical work, a new boundary condition that specifies mass flow rate at the outlet boundary is used to simulate the characteristics around the zero flow rate region. Furthermore, flow field analyses at small or negative flow rate are performed with the numerical results. The separated and re-circulated flow fields are investigated by visualization to identify the origin of losses.

  5. Dissociation in Rating Negative Facial Emotions between Behavioral Variant Frontotemporal Dementia and Major Depressive Disorder.

    Science.gov (United States)

    Chiu, Isabelle; Piguet, Olivier; Diehl-Schmid, Janine; Riedl, Lina; Beck, Johannes; Leyhe, Thomas; Holsboer-Trachsler, Edith; Berres, Manfred; Monsch, Andreas U; Sollberger, Marc

    2016-11-01

    Features of behavioral variant frontotemporal dementia (bvFTD) such as executive dysfunction, apathy, and impaired empathic abilities are also observed in major depressive disorder (MDD). This may contribute to the reason why early stage bvFTD is often misdiagnosed as MDD. New assessment tools are thus needed to improve early diagnosis of bvFTD. Although emotion processing is affected in bvFTD and MDD, growing evidence indicates that the pattern of emotion processing deficits varies between the two disorders. As such, emotion processing paradigms have substantial potentials to distinguish bvFTD from MDD. The current study compared 25 patients with bvFTD, 21 patients with MDD, 21 patients with Alzheimer disease (AD) dementia, and 31 healthy participants on a novel facial emotion intensity rating task. Stimuli comprised morphed faces from the Ekman and Friesen stimulus set containing faces of each sex with two different degrees of emotion intensity for each of the six basic emotions. Analyses of covariance uncovered a significant dissociation between bvFTD and MDD patients in rating the intensity of negative emotions overall (i.e., bvFTD patients underrated negative emotions overall, whereas MDD patients overrated negative emotions overall compared with healthy participants). In contrast, AD dementia patients rated negative emotions similarly to healthy participants, suggesting no impact of cognitive deficits on rating facial emotions. By strongly differentiating bvFTD and MDDpatients through negative facial emotions, this sensitive and short rating task might help improve the early diagnosis of bvFTD. Copyright © 2016 American Association for Geriatric Psychiatry. All rights reserved.

  6. [One example of false negative hepatitis B surface antigen (EIA) result due to variant S area strain and reagment reactiveness related to hepatitis B surface antigen].

    Science.gov (United States)

    Matsuda, Chikashi; Moriyama, Hidehiko; Taketani, Takeshi; Shibata, Hiroshi; Nagai, Atsushi

    2011-01-01

    The presence in serum of the Hepatitis B surface antigen (HBsAg), the outer envelope of the hepatitis B virus (HBV), indicates viral infection, used in laboratory tests to confirm this. We report a case of discrepancy among HBsAg test results detected between measurements in a subject with HB infection. Gene analysis demonstrated several S region gene mutations, not detected previously. We tested 12 measurements e.g., EIA, CLIA, CLEIA, F-EIA, MAT, and IC for whether they could detect our subject's HBsAg and found that it was not recognized by a method using only a single monoclonal antibody to detect HBsAg in two detection processes, in contrast to the 11 other measurements, which used two different antibodies. This case shows that amino acid substitution may cause a false negative result for HBsAg. Gene mutations known to occur in HBV, should thus trigger an awareness of the need to keep in mind that false negative results can happen in case such as ours.

  7. Motivated reconstruction: The effect of brand commitment on false memories.

    Science.gov (United States)

    Montgomery, Nicole Votolato; Rajagopal, Priyali

    2018-06-01

    Across 5 studies, we examine the effect of prior brand commitment on the creation of false memories about product experience after reading online product reviews. We find that brand commitment and the valence of reviews to which consumers are exposed, interact to affect the incidence of false memories. Thus, highly committed consumers are more susceptible to the creation of false experience memories on exposure to positive versus negative reviews, whereas low commitment consumers exhibit similar levels of false memories in response to both positive and negative reviews. Further, these differences across brand commitment are attenuated when respondents are primed with an accuracy motivation, suggesting that the biasing effects of commitment are likely because of the motivation to defend the committed brand. Finally, we find that differences in false memories subsequently lead to differences in intentions to spread word-of-mouth (e.g., recommend the product to friends), suggesting that the consequences of false product experience memories can be significant for marketers and consumers. Our findings contribute to the literatures in false memory and marketing by documenting a motivated bias in false memories because of brand commitment. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  8. Emotional content enhances true but not false memory for categorized stimuli.

    Science.gov (United States)

    Choi, Hae-Yoon; Kensinger, Elizabeth A; Rajaram, Suparna

    2013-04-01

    Past research has shown that emotion enhances true memory, but that emotion can either increase or decrease false memory. Two theoretical possibilities-the distinctiveness of emotional stimuli and the conceptual relatedness of emotional content-have been implicated as being responsible for influencing both true and false memory for emotional content. In the present study, we sought to identify the mechanisms that underlie these mixed findings by equating the thematic relatedness of the study materials across each type of valence used (negative, positive, or neutral). In three experiments, categorically bound stimuli (e.g., funeral, pets, and office items) were used for this purpose. When the encoding task required the processing of thematic relatedness, a significant true-memory enhancement for emotional content emerged in recognition memory, but no emotional boost to false memory (exp. 1). This pattern persisted for true memory with a longer retention interval between study and test (24 h), and false recognition was reduced for emotional items (exp. 2). Finally, better recognition memory for emotional items once again emerged when the encoding task (arousal ratings) required the processing of the emotional aspect of the study items, with no emotional boost to false recognition (EXP. 3). Together, these findings suggest that when emotional and neutral stimuli are equivalently high in thematic relatedness, emotion continues to improve true memory, but it does not override other types of grouping to increase false memory.

  9. Positive events protect children from causal false memories for scripted events.

    Science.gov (United States)

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  10. Increased risk of breast cancer in women with false-positive test

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Kuchiki, Megumi; Vejborg, Ilse

    2014-01-01

    of misclassification, i.e. women who were actually false-negatives instead of false-positives. METHOD: We used data from the Copenhagen Mammography Screening Programme, Denmark. The study population was the 295 women, out of 4743 recalled women from a total of 58,003 participants, with a false-positive test during...... the women with misclassified tests had been excluded, there was an excess risk of breast cancer of 27% (RR=1.27, 95% confidence interval (CI), 1.11-1.46) among the women with a false-positive test compared to women with only negative tests. Women with a false-positive test determined at assessment had...... an excess risk of 27%, while false-positives determined at surgery had an excess risk of 30%. CONCLUSIONS: The results indicate that the increased risk is not explained only by misclassification. The excess risk remains for false-positives determined at assessment as well as at surgery, which favours some...

  11. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  12. The brief negative symptom scale: validation of the German translation and convergent validity with self-rated anhedonia and observer-rated apathy.

    Science.gov (United States)

    Bischof, Martin; Obermann, Caitriona; Hartmann, Matthias N; Hager, Oliver M; Kirschner, Matthias; Kluge, Agne; Strauss, Gregory P; Kaiser, Stefan

    2016-11-22

    Negative symptoms are considered core symptoms of schizophrenia. The Brief Negative Symptom Scale (BNSS) was developed to measure this symptomatic dimension according to a current consensus definition. The present study examined the psychometric properties of the German version of the BNSS. To expand former findings on convergent validity, we employed the Temporal Experience Pleasure Scale (TEPS), a hedonic self-report that distinguishes between consummatory and anticipatory pleasure. Additionally, we addressed convergent validity with observer-rated assessment of apathy with the Apathy Evaluation Scale (AES), which was completed by the patient's primary nurse. Data were collected from 75 in- and outpatients from the Psychiatric Hospital, University Zurich diagnosed with either schizophrenia or schizoaffective disorder. We assessed convergent and discriminant validity, internal consistency and inter-rater reliability. We largely replicated the findings of the original version showing good psychometric properties of the BNSS. In addition, the primary nurses evaluation correlated moderately with interview-based clinician rating. BNSS anhedonia items showed good convergent validity with the TEPS. Overall, the German BNSS shows good psychometric properties comparable to the original English version. Convergent validity extends beyond interview-based assessments of negative symptoms to self-rated anhedonia and observer-rated apathy.

  13. Evaluation of Sentinel Node Biopsy in Locally Advanced Breast Cancer Patients Who Become Clinically Node-Negative after Neoadjuvant Chemotherapy: A Preliminary Study

    International Nuclear Information System (INIS)

    Thomas, Sh.; Prakash, A.; Goyal, V.; Agarwal, Sh.; Choudhury, M.; Popli, M.B.

    2011-01-01

    Introduction. Controversy continues over the appropriate timing of sentinel lymph node (SLN) biopsy in locally advanced breast cancer (LABC) patients receiving neoadjuvant chemotherapy. We evaluated the feasibility and accuracy of SLN biopsy in LABC patients with cytology-proven axillary nodal metastasis who become clinically node-negative after neoadjuvant chemotherapy. Materials. 30 consecutive patients with LABC, who had become clinically node-negative after 3 cycles of neoadjuvant chemotherapy, were included in the study. They were then subjected to SLN biopsy, axillary lymph node dissection, and breast surgery. Results. Sentinel nodes were successfully identified in 26 of the 30 patients, resulting in an identification rate of 86.67%, sensitivity of 83.33%, false negative rate of 20%, negative predictive value of 72.73%, and an overall accuracy of 88.46%. No complications were observed as a result of dye injection. Conclusions. SLN biopsy is feasible and safe in LABC patients with cytology-positive nodes who become clinically node-negative after neoadjuvant chemotherapy. Our accuracy rate, identification rate, and false negative rate are comparable to those in node-negative LABC patients. SLN biopsy as a therapeutic option in LABC after neoadjuvant chemotherapy is a promising option which should be further investigated

  14. False Positives in Exoplanet Detection

    Science.gov (United States)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  15. Negative Nominal Interest Rates: Three ways to overcome the zero lower bound

    OpenAIRE

    Willem H. Buiter

    2009-01-01

    The paper considers three methods for eliminating the zero lower bound on nominal interest rates and thus for restoring symmetry to domain over which the central bank can vary its policy rate. They are: (1) abolishing currency (which would also be a useful crime-fighting measure); (2) paying negative interest on currency by taxing currency; and (3) decoupling the numéraire from the currency/medium of exchange/means of payment and introducing an exchange rate between the numéraire and the curr...

  16. How distributed processing produces false negatives in voxel-based lesion-deficit analyses.

    Science.gov (United States)

    Gajardo-Vidal, Andrea; Lorca-Puls, Diego L; Crinion, Jennifer T; White, Jitrachote; Seghier, Mohamed L; Leff, Alex P; Hope, Thomas M H; Ludersdorfer, Philipp; Green, David W; Bowman, Howard; Price, Cathy J

    2018-07-01

    In this study, we hypothesized that if the same deficit can be caused by damage to one or another part of a distributed neural system, then voxel-based analyses might miss critical lesion sites because preservation of each site will not be consistently associated with preserved function. The first part of our investigation used voxel-based multiple regression analyses of data from 359 right-handed stroke survivors to identify brain regions where lesion load is associated with picture naming abilities after factoring out variance related to object recognition, semantics and speech articulation so as to focus on deficits arising at the word retrieval level. A highly significant lesion-deficit relationship was identified in left temporal and frontal/premotor regions. Post-hoc analyses showed that damage to either of these sites caused the deficit of interest in less than half the affected patients (76/162 = 47%). After excluding all patients with damage to one or both of the identified regions, our second analysis revealed a new region, in the anterior part of the left putamen, which had not been previously detected because many patients had the deficit of interest after temporal or frontal damage that preserved the left putamen. The results illustrate how (i) false negative results arise when the same deficit can be caused by different lesion sites; (ii) some of the missed effects can be unveiled by adopting an iterative approach that systematically excludes patients with lesions to the areas identified in previous analyses, (iii) statistically significant voxel-based lesion-deficit mappings can be driven by a subset of patients; (iv) focal lesions to the identified regions are needed to determine whether the deficit of interest is the consequence of focal damage or much more extensive damage that includes the identified region; and, finally, (v) univariate voxel-based lesion-deficit mappings cannot, in isolation, be used to predict outcome in other patients

  17. Heart rate reactivity associated to positive and negative food and non-food visual stimuli.

    Science.gov (United States)

    Kuoppa, Pekka; Tarvainen, Mika P; Karhunen, Leila; Narvainen, Johanna

    2016-08-01

    Using food as a stimuli is known to cause multiple psychophysiological reactions. Heart rate variability (HRV) is common tool for assessing physiological reactions in autonomic nervous system. However, the findings in HRV related to food stimuli have not been consistent. In this paper the quick changes in HRV related to positive and negative food and non-food visual stimuli are investigated. Electrocardiogram (ECG) was measured from 18 healthy females while being stimulated with the pictures. Subjects also filled Three-Factor Eating Questionnaire to determine their eating behavior. The inter-beat-interval time series and the HRV parameters were extracted from the ECG. The quick change in HRV parameters were studied by calculating the change from baseline value (10 s window before stimulus) to value after the onset of the stimulus (10 s window during stimulus). The paired t-test showed significant difference between positive and negative food pictures but not between positive and negative non-food pictures. All the HRV parameters decreased for positive food pictures while they stayed the same or increased a little for negative food pictures. The eating behavior characteristic cognitive restraint was negatively correlated with HRV parameters that describe decreasing of heart rate.

  18. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    Science.gov (United States)

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  19. ClubSub-P: Cluster-Based Subcellular Localization Prediction for Gram-Negative Bacteria and Archaea

    Science.gov (United States)

    Paramasivam, Nagarajan; Linke, Dirk

    2011-01-01

    The subcellular localization (SCL) of proteins provides important clues to their function in a cell. In our efforts to predict useful vaccine targets against Gram-negative bacteria, we noticed that misannotated start codons frequently lead to wrongly assigned SCLs. This and other problems in SCL prediction, such as the relatively high false-positive and false-negative rates of some tools, can be avoided by applying multiple prediction tools to groups of homologous proteins. Here we present ClubSub-P, an online database that combines existing SCL prediction tools into a consensus pipeline from more than 600 proteomes of fully sequenced microorganisms. On top of the consensus prediction at the level of single sequences, the tool uses clusters of homologous proteins from Gram-negative bacteria and from Archaea to eliminate false-positive and false-negative predictions. ClubSub-P can assign the SCL of proteins from Gram-negative bacteria and Archaea with high precision. The database is searchable, and can easily be expanded using either new bacterial genomes or new prediction tools as they become available. This will further improve the performance of the SCL prediction, as well as the detection of misannotated start codons and other annotation errors. ClubSub-P is available online at http://toolkit.tuebingen.mpg.de/clubsubp/ PMID:22073040

  20. Attention Cueing and Activity Equally Reduce False Alarm Rate in Visual-Auditory Associative Learning through Improving Memory.

    Science.gov (United States)

    Nikouei Mahani, Mohammad-Ali; Haghgoo, Hojjat Allah; Azizi, Solmaz; Nili Ahmadabadi, Majid

    2016-01-01

    In our daily life, we continually exploit already learned multisensory associations and form new ones when facing novel situations. Improving our associative learning results in higher cognitive capabilities. We experimentally and computationally studied the learning performance of healthy subjects in a visual-auditory sensory associative learning task across active learning, attention cueing learning, and passive learning modes. According to our results, the learning mode had no significant effect on learning association of congruent pairs. In addition, subjects' performance in learning congruent samples was not correlated with their vigilance score. Nevertheless, vigilance score was significantly correlated with the learning performance of the non-congruent pairs. Moreover, in the last block of the passive learning mode, subjects significantly made more mistakes in taking non-congruent pairs as associated and consciously reported lower confidence. These results indicate that attention and activity equally enhanced visual-auditory associative learning for non-congruent pairs, while false alarm rate in the passive learning mode did not decrease after the second block. We investigated the cause of higher false alarm rate in the passive learning mode by using a computational model, composed of a reinforcement learning module and a memory-decay module. The results suggest that the higher rate of memory decay is the source of making more mistakes and reporting lower confidence in non-congruent pairs in the passive learning mode.

  1. The effect of mood on false memory for emotional DRM word lists.

    Science.gov (United States)

    Zhang, Weiwei; Gross, Julien; Hayne, Harlene

    2017-04-01

    In the present study, we investigated the effect of participants' mood on true and false memories of emotional word lists in the Deese-Roediger-McDermott (DRM) paradigm. In Experiment 1, we constructed DRM word lists in which all the studied words and corresponding critical lures reflected a specified emotional valence. In Experiment 2, we used these lists to assess mood-congruent true and false memory. Participants were randomly assigned to one of three induced-mood conditions (positive, negative, or neutral) and were presented with word lists comprised of positive, negative, or neutral words. For both true and false memory, there was a mood-congruent effect in the negative mood condition; this effect was due to a decrease in true and false recognition of the positive and neutral words. These findings are consistent with both spreading-activation and fuzzy-trace theories of DRM performance and have practical implications for our understanding of the effect of mood on memory.

  2. Relationship between obesity, negative affect and basal heart rate in predicting heart rate reactivity to psychological stress among adolescents.

    Science.gov (United States)

    Park, Andres E; Huynh, Pauline; Schell, Anne M; Baker, Laura A

    2015-08-01

    Reduced cardiovascular responses to psychological stressors have been found to be associated with both obesity and negative affect in adults, but have been less well studied in children and adolescent populations. These findings have most often been interpreted as reflecting reduced sympathetic nervous system response, perhaps associated with heightened baseline sympathetic activation among the obese and those manifesting negative affect. However, obesity and negative affect may themselves be correlated, raising the question of whether they both independently affect cardiovascular reactivity. The present study thus examined the separate effects of obesity and negative affect on both cardiovascular and skin conductance responses to stress (e.g., during a serial subtraction math task) in adolescents, while controlling for baseline levels of autonomic activity during rest. Both obesity and negative affect had independent and negative associations with cardiovascular reactivity, such that reduced stress responses were apparent for obese adolescents and those with high levels of negative affect. In contrast, neither obesity nor negative affect was related to skin conductance responses to stress, implicating specifically noradrenergic mechanisms rather than sympathetic mechanisms generally as being deficient. Moreover, baseline heart rate was unrelated to obesity in this sample, which suggests that heightened baseline of sympathetic activity is not necessary for the reduced cardiovascular reactivity to stress. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Individual differences in heart rate variability are associated with the avoidance of negative emotional events.

    Science.gov (United States)

    Katahira, Kentaro; Fujimura, Tomomi; Matsuda, Yoshi-Taka; Okanoya, Kazuo; Okada, Masato

    2014-12-01

    Although the emotional outcome of a choice generally affects subsequent decisions, humans can inhibit the influence of emotion. Heart rate variability (HRV) has emerged as an objective measure of individual differences in the capacity for inhibitory control. In the present study, we investigated how individual differences in HRV at rest are associated with the emotional effects of the outcome of a choice on subsequent decision making using a decision-making task in which emotional pictures appeared as decision outcomes. We used a reinforcement learning model to characterize the observed behaviors according to several parameters, namely, the learning rate and the motivational value of positive and negative pictures. Consequently, we found that individuals with a lower resting HRV exhibited a greater negative motivational value in response to negative pictures, suggesting that these individuals tend to avoid negative pictures compared with individuals with a higher resting HRV. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    International Nuclear Information System (INIS)

    Désert, Jean-Michel; Brown, Timothy M.; Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W.; Bryson, Stephen T.; Borucki, William J.; Knutson, Heather A.; Batalha, Natalie M.; Deming, Drake; Ford, Eric B.; Fortney, Jonathan J.; Gilliland, Ronald L.; Seager, Sara

    2015-01-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  5. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Désert, Jean-Michel; Brown, Timothy M. [CASA, Department of Astrophysical and Planetary Sciences, University of Colorado, 389-UCB, Boulder, CO 80309 (United States); Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Bryson, Stephen T.; Borucki, William J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Knutson, Heather A. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Batalha, Natalie M. [San Jose State University, San Jose, CA 95192 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Ford, Eric B. [University of Florida, Gainesville, FL 32611 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Gilliland, Ronald L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Seager, Sara, E-mail: desert@colorado.edu [Massachusetts Institute of Technology, Cambridge, MA 02159 (United States)

    2015-05-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  6. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Science.gov (United States)

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  7. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Directory of Open Access Journals (Sweden)

    Leslie Shanks

    Full Text Available Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals.Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367 in the VL group compared to 7.9% (200/2526 in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively.The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  8. Effects of Instructions on False Recognition.

    Science.gov (United States)

    Mueller, John H.; And Others

    Four experiments were conducted to examine the effects of various processing instructions on the rate of false recognition. The continuous single-item procedure was used, and false recognitions of four types were examined: synonyms, antonyms, nonsemantic associates, and homonyms. The instructions encouraged subjects to think of associates, usages…

  9. ClubSub-P: Cluster-based subcellular localization prediction for Gram-negative bacteria and Archaea.

    Directory of Open Access Journals (Sweden)

    Nagarajan eParamasivam

    2011-11-01

    Full Text Available The subcellular localization of proteins provides important clues to their function in a cell. In our efforts to predict useful vaccine targets against Gram-negative bacteria, we noticed that misannotated start codons frequently lead to wrongly assigned subcellular localizations. This and other problems in subcellular localization prediction, such as the relatively high false positive and false negative rates of some tools, can be avoided by applying multiple prediction tools to groups of homologous proteins. Here we present ClubSub-P, an online database that combines existing subcellular localization prediction tools into a consensus pipeline from more than 600 proteomes of fully sequenced microorganisms. On top of the consensus prediction at the level of single sequences, the tool uses clusters of homologous proteins from Gram-negative bacteria and from Archaea to eliminate false positive and false negative predictions. ClubSub-P can assign the subcellular localization of proteins from Gram-negative bacteria and Archaea with high precision. The database is searchable, and can easily be expanded using either new bacterial genomes or new prediction tools as they become available. This will further improve the performance of the subcellular localization prediction, as well as the detection of misannotated start codons and other annotation errors. ClubSub-P is available online at http://toolkit.tuebingen.mpg.de/clubsubp/

  10. Dividing Attention Lowers Children's but Increases Adults' False Memories

    Science.gov (United States)

    Otgaar, Henry; Peters, Maarten; Howe, Mark L.

    2012-01-01

    The present study examined the impact of divided attention on children's and adults' neutral and negative true and false memories in a standard Deese/Roediger-McDermott paradigm. Children (7- and 11-year-olds; n = 126) and adults (n = 52) received 5 neutral and 5 negative Deese/Roediger-McDermott word lists; half of each group also received a…

  11. How much can a negative FDG-PET be trusted?

    International Nuclear Information System (INIS)

    Wang Shuxia

    2004-01-01

    Purpose: False-negative FDG-PET constituted 22.7% of all clinically identified negative PET in a ten year retrospective review about FDG-PET on irradiated brain tumour. Uncovering possible influencing factors of false-negative FDG-PET may have significant value. Material and methods: 10 patients with a first negative and then a second positive PET during very short time separation and 6 patients with surgically confirmed false-negative PET were traced. Histological type, irradiation parameter, steroids effect were discussed. To define temporary irradiation effect on FDG uptake, interval between radiation treatment to PET examination of these two groups were compared with 24 surgically confirmed true-positive PET, 5 surgically confirmed true-negative PET Results: 80% negative-positive PET transformation happened within 31 weeks. No statistically significant difference with regard to time from irradiation could be found between groups. Steroids medication closely before PET examination was about the same before the first negative and second positive PET scan. 5/6 surgically confirmed false-negative PET patients did not take steroids before PET examination. Conclusion: Tumour histology type, temporary irradiation effect and steroids medication did not constitute the reasons for false negative PET in our patient series. PET could not identify tumour relapse in the very early stage. Therefore, if clinically indicated, second FDG-PET might be a better selection to pick up tumour relapse instead of exploratory surgery or biopsy. In that case, the suitable time point for the second PET could be within 31 weeks after the first PET examination. Keywords: false-negative, FDG-PET, influencing factor, irradiation effect, steroids. (author)

  12. False memory in aging resulting from self-referential processing.

    Science.gov (United States)

    Rosa, Nicole M; Gutchess, Angela H

    2013-11-01

    Referencing the self is known to enhance accurate memory, but less is known about how the strategy affects false memory, particularly for highly self-relevant information. Because older adults are more prone to false memories, we tested whether self-referencing increased false memories with age. In 2 studies, older and younger adults rated adjectives for self-descriptiveness and later completed a surprise recognition test comprised of words rated previously for self-descriptiveness and novel lure words. Lure words were subsequently rated for self-descriptiveness in order to assess the impact of self-relevance on false memory. Study 2 introduced commonness judgments as a control condition, such that participants completed a recognition test on adjectives rated for commonness in addition to adjectives in the self-descriptiveness condition. Across both studies, findings indicate an increased response bias to self-referencing that increased hit rates for both older and younger adults but also increased false alarms as information became more self-descriptive, particularly for older adults. Although the present study supports previous literature showing a boost in memory for self-referenced information, the increase in false alarms, especially in older adults, highlights the potential for memory errors, particularly for information that is strongly related to the self.

  13. A Highly Sensitive Telomerase Activity Assay that Eliminates False-Negative Results Caused by PCR Inhibitors

    Directory of Open Access Journals (Sweden)

    Hidenobu Yaku

    2013-09-01

    Full Text Available An assay for telomerase activity based on asymmetric polymerase chain reaction (A-PCR on magnetic beads (MBs and subsequent application of cycling probe technology (CPT is described. In this assay, the telomerase reaction products are immobilized on MBs, which are then washed to remove PCR inhibitors that are commonly found in clinical samples. The guanine-rich sequences (5'-(TTAGGGn-3' of the telomerase reaction products are then preferentially amplified by A-PCR, and the amplified products are subsequently detected via CPT, where a probe RNA with a fluorophore at the 5' end and a quencher at the 3' end is hydrolyzed by RNase H in the presence of the target DNA. The catalyst-mediated cleavage of the probe RNA enhances fluorescence from the 5' end of the probe. The assay allowed us to successfully detect HeLa cells selectively over normal human dermal fibroblast (NHDF cells. Importantly, this selectivity produced identical results with regard to detection of HeLa cells in the absence and presence of excess NHDF cells; therefore, this assay can be used for practical clinical applications. The lower limit of detection for HeLa cells was 50 cells, which is lower than that achieved with a conventional telomeric repeat amplification protocol assay. Our assay also eliminated false-negative results caused by PCR inhibitors. Furthermore, we show that this assay is appropriate for screening among G-quadruplex ligands to find those that inhibit telomerase activity.

  14. Mood-congruent true and false memory: effects of depression.

    Science.gov (United States)

    Howe, Mark L; Malone, Catherine

    2011-02-01

    The Deese/Roediger-McDermott paradigm was used to investigate the effect of depression on true and false recognition. In this experiment true and false recognition was examined across positive, neutral, negative, and depression-relevant lists for individuals with and without a diagnosis of major depressive disorder. Results showed that participants with major depressive disorder falsely recognised significantly more depression-relevant words than non-depressed controls. These findings also parallel recent research using recall instead of recognition and show that there are clear mood congruence effects for depression on false memory performance. © 2011 Psychology Press, an imprint of the Taylor & Francis Group, an Informa business

  15. Making up History: False Memories of Fake News Stories

    Directory of Open Access Journals (Sweden)

    Danielle C. Polage

    2012-05-01

    Full Text Available Previous research has shown that information that is repeated is more likely to be rated as true than information that has not been heard before. The current experiment examines whether familiarity with false news stories would increase rates of truthfulness and plausibility for these events. Further, the experiment tested whether false stories that were familiar would result in the creation of a false memory of having heard the story outside of the experiment. Participants were exposed to false new stories, each portrayed by the investigator as true news stories. After a five week delay, participants who had read the false experimental stories rated them as more truthful and more plausible than participants who had not been exposed to the stories. In addition, there was evidence of the creation of false memories for the source of the news story. Participants who had previously read about the stories were more likely to believe that they had heard the false stories from a source outside the experiment. These results suggest that repeating false claims will not only increase their believability but may also result in source monitoring errors.

  16. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    Science.gov (United States)

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason  7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  17. Implications of false-positive results for future cancer screenings.

    Science.gov (United States)

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both Pfalse-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; Pfalse-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  18. Growth rate correlates negatively with protein turnover in Arabidopsis accessions.

    Science.gov (United States)

    Ishihara, Hirofumi; Moraes, Thiago Alexandre; Pyl, Eva-Theresa; Schulze, Waltraud X; Obata, Toshihiro; Scheffel, André; Fernie, Alisdair R; Sulpice, Ronan; Stitt, Mark

    2017-08-01

    Previous studies with Arabidopsis accessions revealed that biomass correlates negatively to dusk starch content and total protein, and positively to the maximum activities of enzymes in photosynthesis. We hypothesized that large accessions have lower ribosome abundance and lower rates of protein synthesis, and that this is compensated by lower rates of protein degradation. This would increase growth efficiency and allow more investment in photosynthetic machinery. We analysed ribosome abundance and polysome loading in 19 accessions, modelled the rates of protein synthesis and compared them with the observed rate of growth. Large accessions contained less ribosomes than small accessions, due mainly to cytosolic ribosome abundance falling at night in large accessions. The modelled rates of protein synthesis resembled those required for growth in large accessions, but were up to 30% in excess in small accessions. We then employed 13 CO 2 pulse-chase labelling to measure the rates of protein synthesis and degradation in 13 accessions. Small accessions had a slightly higher rate of protein synthesis and much higher rates of protein degradation than large accessions. Protein turnover was negligible in large accessions but equivalent to up to 30% of synthesised protein day -1 in small accessions. We discuss to what extent the decrease in growth in small accessions can be quantitatively explained by known costs of protein turnover and what factors may lead to the altered diurnal dynamics and increase of ribosome abundance in small accessions, and propose that there is a trade-off between protein turnover and maximisation of growth rate. © 2017 The Authors The Plant Journal © 2017 John Wiley & Sons Ltd.

  19. Sample size reassessment for a two-stage design controlling the false discovery rate.

    Science.gov (United States)

    Zehetmayer, Sonja; Graf, Alexandra C; Posch, Martin

    2015-11-01

    Sample size calculations for gene expression microarray and NGS-RNA-Seq experiments are challenging because the overall power depends on unknown quantities as the proportion of true null hypotheses and the distribution of the effect sizes under the alternative. We propose a two-stage design with an adaptive interim analysis where these quantities are estimated from the interim data. The second stage sample size is chosen based on these estimates to achieve a specific overall power. The proposed procedure controls the power in all considered scenarios except for very low first stage sample sizes. The false discovery rate (FDR) is controlled despite of the data dependent choice of sample size. The two-stage design can be a useful tool to determine the sample size of high-dimensional studies if in the planning phase there is high uncertainty regarding the expected effect sizes and variability.

  20. Generation of a bubble universe using a negative energy bath

    International Nuclear Information System (INIS)

    Hwang, Dong-il; Yeom, Dong-han

    2011-01-01

    This paper suggests a model for a bubble universe using buildable false vacuum bubbles. We study the causal structures of collapsing false vacuum bubbles using double-null simulations. False vacuum bubbles violate the null energy condition and emit negative energy along the outgoing direction through semi-classical effects. If there are a few collapsing false vacuum bubbles and they emit negative energy to a certain region, then the region can be approximated by a negative energy bath, which means that the region is homogeneously filled by negative energy. If a false vacuum bubble is generated in the negative energy bath and the tension of the bubble effectively becomes negative in the bath, then the bubble can expand and form an inflating bubble universe. This scenario uses a set of assumptions different from those in previous studies because it does not require tunneling to unbuildable bubbles.

  1. Rating the Raters: Legal Exposure of Trustmark Authorities in the Context of Consumer Health Informatics

    Science.gov (United States)

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in e-health quality rating. First, an e-health provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on e-health data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the e-health data provider, questions may arise as to the possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations, and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, the introduction of legislation. PMID:11720941

  2. Rating the "Raters": Legal Exposure of Trustmark Authorities in the Context of Consumer Health Informatics

    Science.gov (United States)

    Terry, Nicolas P

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in ehealth quality rating. First, an ehealth provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on ehealth data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the ehealth data provider, questions may arise as to possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, legislation.

  3. False belief reasoning in the brain: An ERP study

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Understanding others mind and interpersonal interaction are the cognitive basis of successful social interactions. People’s mental states and behaviors rely on their holding beliefs for self and others. To investigate the neural substrates of false belief reasoning, the 32 channels event-related potentials (ERP) of 14 normal adults were measured while they understood false-belief and true belief used de-ceptive appearance task. After onset of the false-belief or true-belief questions, N100, P200 and late negative component (LNC) were elicited at centro-frontal sites. Compared with true belief, false belief reasoning elicited significant declined LNC in the time window from 400 to 800 ms. The source analysis of difference wave (False minus True) showed a dipole located in the middle cingulated cortex. These findings show that false belief reasoning probably included inhibitive process.

  4. False belief reasoning in the brain: An ERP study

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Understanding others mind and interpersonal interaction are the cognitive basis of successful social interactions. People's mental states and behaviors rely on their holding beliefs for self and others. To investigate the neural substrates of false belief reasoning, the 32 channels event-related potentials (ERP) of 14 normal adults were measured while they understood false-belief and true belief used deceptive appearance task. After onset of the false-belief or true-belief questions, N100, P200 and late negative component (LNC) were elicited at centro-frontal sites. Compared with true belief, false belief reasoning elicited significant declined LNC in the time window from 400 to 800 ms. The source analysis of difference wave (False minus True) showed a dipole located in the middle cingulated cortex. These findings show that false belief reasoning probably included inhibitive process.

  5. Pluto behaving badly: false beliefs and their consequences.

    Science.gov (United States)

    Berkowitz, Shari R; Laney, Cara; Morris, Erin K; Garry, Maryanne; Loftus, Elizabeth F

    2008-01-01

    We exposed college students to suggestive materials in order to lead them to believe that, as children, they had a negative experience at Disneyland involving the Pluto character. A sizable minority of subjects developed a false belief or memory that Pluto had uncomfortably licked their ear. Suggestions about a positive experience with Pluto led to even greater acceptance of a lovable ear-licking episode. False beliefs and memories had repercussions; those seduced by the bad suggestions were not willing to pay as much for a Pluto souvenir. These findings are among the first to demonstrate that false beliefs can have repercussions for people, meaning that they can influence their later thoughts, beliefs, and behaviors.

  6. Maltreated and non-maltreated children's true and false memories of neutral and emotional word lists in the Deese/Roediger-McDermott task.

    Science.gov (United States)

    Baugerud, Gunn Astrid; Howe, Mark L; Magnussen, Svein; Melinder, Annika

    2016-03-01

    Maltreated (n=26) and non-maltreated (n=31) 7- to 12-year-old children were tested on the Deese/Roediger-McDermott (DRM) false memory task using emotional and neutral word lists. True recall was significantly better for non-maltreated than maltreated children regardless of list valence. The proportion of false recall for neutral lists was comparable regardless of maltreatment status. However, maltreated children showed a significantly higher false recall rate for the emotional lists than non-maltreated children. Together, these results provide new evidence that maltreated children could be more prone to false memory illusions for negatively valenced information than their non-maltreated counterparts. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Impact of negative emotion on the neural correlates of long-term recognition in younger and older adults

    Directory of Open Access Journals (Sweden)

    Grégoria eKalpouzos

    2012-09-01

    Full Text Available Some studies have suggested that the memory advantage for negative emotional information over neutral information (negativity effect is reduced in aging. Besides the fact that most findings are based on immediate retrieval, the neural underpinnings of long-term emotional memory in aging have so far not been investigated. To address these issues, we assessed recognition of neutral and negative scenes after one- and 3-week retention intervals in younger and older adults using fMRI. We further used an event-related design in order to disentangle successful, false and true recognition. This study revealed 4 key findings: 1 Increased retention interval induced an increased rate of false recognitions for negative scenes, cancelling out the negativity effect (present for hit rates only on discrimination in both younger and older adults; 2 In younger, but not older, adults, reduced activity of the medial temporal lobe was observed over time for neutral scenes, but not for negative scenes, where stable or increased activity was seen; 3 Engagement of amygdala was observed in older adults after a 3-week delay during successful recognition of negative scenes (hits versus misses in comparison with neutral scenes, which may indicate engagement of automatic processes, but engagement of ventrolateral prefrontal cortex was unrelated to amygdala activity and performance; and 4 After 3 weeks, but not after one week, true recognition of negative scenes was characterized by more activity in left hippocampus and lateral occipito-temporal regions (hits versus false alarms. As these regions are known to be related to consolidation mechanisms, the observed pattern may indicate the presence of delayed consolidation of true memories. Nonetheless, older adults’ low performance in discrimination of negative scenes could reflect the fact that overall, after long delays of retention, they rely more on general information rather than on perceptual detail in making

  8. Disordered carbon negative electrode for electrochemical capacitors and high-rate batteries

    International Nuclear Information System (INIS)

    Ogihara, Nobuhiro; Igarashi, Yoshiyuki; Kamakura, Ayumu; Naoi, Katsuhiko; Kusachi, Yuki; Utsugi, Koji

    2006-01-01

    In order to understand the properties of high-rate capability and cycleability for a disordered carbon negative electrode in LiPF 6 /PC based electrolyte solution, the cell performance tests with various rates and depth of discharges (DODs) has been studied by spectroscopic and electrochemical analyses. From the charge-discharge measurements, a surface carbon-edge redox reaction occurring between a carbonyl (C edge =O) and a lithium alkoxide (C edge -OLi) that delivers a large capacity was found fast and high cycleability at only shallow DOD (2.0-0.4 V). The limited or shallow charge-discharge cycling utilizing such facile and reversible action of the C edge =O/C edge -OLi of the disordered carbon is suited to an application for an negative electrode of asymmetric hybrid capacitors. A deep DOD discharge (2.0-0.0 V) revealed the existence of some complex processes involving a lithium cluster deposition at pores or microvoids as well as a lithium ion intercalation at graphene layers. The cluster deposition at pores was found to be relatively fast and reproducible. The lithium ion intercalation at graphenes and the subsequent cluster deposition at microvoids were found to be slow and degrade the cycleability after 100 cycles because of the accumulation of a thick and low-ion-conductive solid electrolyte interface (SEI) film on surface

  9. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    Science.gov (United States)

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  10. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    Science.gov (United States)

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Reducing false asystole alarms in intensive care.

    Science.gov (United States)

    Dekimpe, Remi; Heldt, Thomas

    2017-07-01

    High rates of false monitoring alarms in intensive care can desensitize staff and therefore pose a significant risk to patient safety. Like other critical arrhythmia alarms, asystole alarms require immediate attention by the care providers as a true asystole event can be acutely life threatening. Here, it is illustrated that most false asystole alarms can be attributed to poor signal quality, and we propose and evaluate an algorithm to identify data windows of poor signal quality and thereby help suppress false asystole alarms. The algorithm combines intuitive signal-quality features (degree of signal saturation and baseline wander) and information from other physiological signals that might be available. Algorithm training and testing was performed on the MIMIC II and 2015 PhysioNet/Computing in Cardiology Challenge databases, respectively. The algorithm achieved an alarm specificity of 81.0% and sensitivity of 95.4%, missing only one out of 22 true asystole alarms. On a separate neonatal data set, the algorithm was able to reject 89.7% (890 out of 992) of false asystole alarms while keeping all 22 true events. The results show that the false asystole alarm rate can be significantly reduced through basic signal quality evaluation.

  12. TargetMiner: microRNA target prediction with systematic identification of tissue-specific negative examples.

    Science.gov (United States)

    Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna

    2009-10-15

    Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the

  13. Characterization and correction of the false-discovery rates in resting state connectivity using functional near-infrared spectroscopy

    Science.gov (United States)

    Santosa, Hendrik; Aarabi, Ardalan; Perlman, Susan B.; Huppert, Theodore J.

    2017-05-01

    Functional near-infrared spectroscopy (fNIRS) is a noninvasive neuroimaging technique that uses low levels of red to near-infrared light to measure changes in cerebral blood oxygenation. Spontaneous (resting state) functional connectivity (sFC) has become a critical tool for cognitive neuroscience for understanding task-independent neural networks, revealing pertinent details differentiating healthy from disordered brain function, and discovering fluctuations in the synchronization of interacting individuals during hyperscanning paradigms. Two of the main challenges to sFC-NIRS analysis are (i) the slow temporal structure of both systemic physiology and the response of blood vessels, which introduces false spurious correlations, and (ii) motion-related artifacts that result from movement of the fNIRS sensors on the participants' head and can introduce non-normal and heavy-tailed noise structures. In this work, we systematically examine the false-discovery rates of several time- and frequency-domain metrics of functional connectivity for characterizing sFC-NIRS. Specifically, we detail the modifications to the statistical models of these methods needed to avoid high levels of false-discovery related to these two sources of noise in fNIRS. We compare these analysis procedures using both simulated and experimental resting-state fNIRS data. Our proposed robust correlation method has better performance in terms of being more reliable to the noise outliers due to the motion artifacts.

  14. Emotionally negative pictures enhance gist memory.

    Science.gov (United States)

    Bookbinder, S H; Brainerd, C J

    2017-02-01

    In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are caused by valence and which are caused by arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling revealed that negative valence (a) reduced erroneous suppression of true memories and (b) increased the familiarity of the semantic content of both true and false memories. Overall, negative valence impaired the verbatim side of episodic memory but enhanced the gist side, and these effects persisted even after a week-long delay. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Emotion and false memory: How goal-irrelevance can be relevant for what people remember.

    Science.gov (United States)

    Van Damme, Ilse; Kaplan, Robin L; Levine, Linda J; Loftus, Elizabeth F

    2017-02-01

    Elaborating on misleading information concerning emotional events can lead people to form false memories. The present experiment compared participants' susceptibility to false memories when they elaborated on information associated with positive versus negative emotion and pregoal versus postgoal emotion. Pregoal emotion reflects appraisals that goal attainment or failure is anticipated but has not yet occurred (e.g., hope and fear). Postgoal emotion reflects appraisals that goal attainment or failure has already occurred (e.g., happiness and devastation). Participants watched a slideshow depicting an interaction between a couple and were asked to empathise with the protagonist's feelings of hope (positive pregoal), happiness (positive postgoal), fear (negative pregoal), or devastation (negative postgoal); in control conditions, no emotion was mentioned. Participants were then asked to reflect on details of the interaction that had occurred (true) or had not occurred (false), and that were relevant or irrelevant to the protagonist's goal. Irrespective of emotional valence, participants in the pregoal conditions were more susceptible to false memories concerning goal-irrelevant details than were participants in the other conditions. These findings support the view that pregoal emotions narrow attention to information relevant to goal pursuit, increasing susceptibility to false memories for irrelevant information.

  16. Publication bias and the canonization of false facts

    DEFF Research Database (Denmark)

    Nissen, Silas Boye; Magidson, Tali; Gross, Kevin

    2016-01-01

    canonized as fact. Data-dredging, p-hacking, and similar behaviors exacerbate the problem. Should negative results become easier to publish as a claim approaches acceptance as a fact, however, true and false claims would be more readily distinguished. To the degree that the model reflects the real world...

  17. The Lifetime Economic Burden of Inaccurate HER2 Testing: Estimating the Costs of False-Positive and False-Negative HER2 Test Results in US Patients with Early-Stage Breast Cancer.

    Science.gov (United States)

    Garrison, Louis P; Babigumira, Joseph B; Masaquel, Anthony; Wang, Bruce C M; Lalla, Deepa; Brammer, Melissa

    2015-06-01

    Patients with breast cancer whose tumors test positive for human epidermal growth factor receptor 2 (HER2) are treated with HER2-targeted therapies such as trastuzumab, but limitations with HER2 testing may lead to false-positive (FP) or false-negative (FN) results. To develop a US-level model to estimate the effect of tumor misclassification on health care costs and patient quality-adjusted life-years (QALYs). Decision analysis was used to estimate the number of patients with early-stage breast cancer (EBC) whose HER2 status was misclassified in 2012. FP results were assumed to generate unnecessary trastuzumab costs and unnecessary cases of trastuzumab-related cardiotoxicity. FN results were assumed to save money on trastuzumab, but with a loss of QALYs and greater risk of disease recurrence and its associated costs. QALYs were valued at $100,000 under a net monetary benefit approach. Among 226,870 women diagnosed with EBC in 2012, 3.12% (n = 7,070) and 2.18% (n = 4,955) were estimated to have had FP and FN test results, respectively. Approximately 8400 QALYs (discounted, lifetime) were lost among women not receiving trastuzumab because of FN results. The estimated incremental per-patient lifetime burden of FP or FN results was $58,900 and $116,000, respectively. The implied incremental losses to society were $417 million and $575 million, respectively. HER2 tests result in misclassification and nonoptimal treatment of approximately 12,025 US patients with EBC annually. The total economic societal loss of nearly $1 billion suggests that improvements in HER2 testing accuracy are needed and that further clinical and economic studies are warranted. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  18. A high false positive rate for Kepler planetary candidates of giant stars using asterodensity profiling

    International Nuclear Information System (INIS)

    Sliski, David H.; Kipping, David M.

    2014-01-01

    Asterodensity profiling (AP) is a relatively new technique for studying transit light curves. By comparing the mean stellar density derived from the transit light curve to that found through an independent method, AP provides information on several useful properties such as orbital eccentricity and blended light. We present an AP survey of 41 Kepler Objects of Interest (KOIs), with a single transiting candidate, for which the target star's mean stellar density has been measured using asteroseismology. The ensemble distribution of the AP measurements for the 31 dwarf stars in our sample shows excellent agreement with the spread expected if the KOIs were genuine and have realistic eccentricities. In contrast, the same test for the 10 giants in our sample reveals significant incompatibility at >4σ confidence. While extreme eccentricities could be invoked, this hypothesis requires four of the KOIs to contact their host star at periastron passage, including the recently claimed confirmation of Kepler-91b. After carefully examining several hypotheses, we conclude that the most plausible explanation is that the transiting objects orbit a different star to that measured with asteroseismology—cases we define as false-positives. Based on the AP distribution, we estimate a false-positive rate (FPR) for Kepler's giant stars with a single transiting object of FPR ≅ 70% ± 30%.

  19. Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF6

    International Nuclear Information System (INIS)

    Draghici, M.; Stamate, E.

    2010-01-01

    Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF 6 gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive and negative ions are evaluated on silicon substrate for different Ar/SF 6 gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.

  20. Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF6

    DEFF Research Database (Denmark)

    Draghici, Mihai; Stamate, Eugen

    2010-01-01

    of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive...... and negative ions are evaluated on silicon substrate for different Ar/SF6 gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.......Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF6 gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio...

  1. Regular and negative self-rated health in students from a public university fromNortheastern,Brazil: prevalence and associated factors

    Directory of Open Access Journals (Sweden)

    Thiago Ferreira de Sousa

    2014-10-01

    Full Text Available Self-rated health is a major health indicator and has been widely used in epidemiologic surveys. Current study analyzes the factors associated to regular and negative self-rated health in Brazilian college students. Current investigation is a segment of the 2010 MONISA study carried out in a Brazilian public university with 5,461 students. Estimated sample comprised 1,232 university students and results showed self-rated regular and negative health. Multinomial logistic regression estimated Odds Ratio (OR. The factors associated to regular health self-evaluation negative assessment of relationship with professors (OR: 1.85; CI95%: 1.20-2.87; inactivity in leisure (OR: 2.34; CI95%: 1.73-3.16; insufficient consumption of vegetables; almost daily consumption of soft drinks; assessment of intermediate and negative stress (OR: 3.34; CI95%: 2.11-5.28. Students inactive in leisure (OR: 2.37; 95%CI: 1.09-5.13, students with self-evaluated negative stress (OR: 10.1; 95%CI: 3.23-31.8 and obese students (OR: 4.52; 95%CI: 1.36-15.0 were associated to the negative health self-assessment. It has been verified that health behavior is rather associated to the regular self-assessment of health, whereas perceptive and biological indicators were more associated to negative health self-assessment.

  2. Improved detection of common variants associated with schizophrenia and bipolar disorder using pleiotropy-informed conditional false discovery rate

    DEFF Research Database (Denmark)

    Andreassen, Ole A; Thompson, Wesley K; Schork, Andrew J

    2013-01-01

    are currently lacking. Here, we use a genetic pleiotropy-informed conditional false discovery rate (FDR) method on GWAS summary statistics data to identify new loci associated with schizophrenia (SCZ) and bipolar disorders (BD), two highly heritable disorders with significant missing heritability...... associated with both SCZ and BD (conjunction FDR). Together, these findings show the feasibility of genetic pleiotropy-informed methods to improve gene discovery in SCZ and BD and indicate overlapping genetic mechanisms between these two disorders....

  3. A broken promise: microbiome differential abundance methods do not control the false discovery rate.

    Science.gov (United States)

    Hawinkel, Stijn; Mattiello, Federico; Bijnens, Luc; Thas, Olivier

    2017-08-22

    High-throughput sequencing technologies allow easy characterization of the human microbiome, but the statistical methods to analyze microbiome data are still in their infancy. Differential abundance methods aim at detecting associations between the abundances of bacterial species and subject grouping factors. The results of such methods are important to identify the microbiome as a prognostic or diagnostic biomarker or to demonstrate efficacy of prodrug or antibiotic drugs. Because of a lack of benchmarking studies in the microbiome field, no consensus exists on the performance of the statistical methods. We have compared a large number of popular methods through extensive parametric and nonparametric simulation as well as real data shuffling algorithms. The results are consistent over the different approaches and all point to an alarming excess of false discoveries. This raises great doubts about the reliability of discoveries in past studies and imperils reproducibility of microbiome experiments. To further improve method benchmarking, we introduce a new simulation tool that allows to generate correlated count data following any univariate count distribution; the correlation structure may be inferred from real data. Most simulation studies discard the correlation between species, but our results indicate that this correlation can negatively affect the performance of statistical methods. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. A misleading false-negative result using Neisseria gonorrhoeae opa MGB multiplex PCR assay in patient's rectal sample due to partial mutations of the opa gene.

    Science.gov (United States)

    Vahidnia, Ali; van Empel, Pieter Jan; Costa, Sandra; Oud, Rob T N; van der Straaten, Tahar; Bliekendaal, Harry; Spaargaren, Joke

    2015-07-01

    A 53-year-old homosexual man presented at his general practitioner (GP) practice with a suspicion of sexually transmitted infection. Initial NAAT screening was performed for Chlamydia trachomatis and Neisseria gonorrhoeae. The patient was positive for Neisseria gonorrhoeae both for his urine and rectal sample. The subsequent confirmation test for Neisseria gonorrhoeae by a second laboratory was only confirmed for the urine sample and the rectal sample was negative. We report a case of a potential false-negative diagnosis of Neisseria gonorrhoeae due to mutations of DNA sequence in the probe region of opa-MGB assay of the rectal sample. The patient did not suffer any discomfort as diagnosis of Neisseria gonorrhoeae in his urine sample had already led to treatment by prescribing the patient with Ceftriaxone 500 mg IV dissolved in 1 ml lidocaine 2% and 4 mL saline. The patient also received a prescription for Azithromycin (2x500 mg).

  5. Decline in oil prices and the negative interest rate policy in Japan

    OpenAIRE

    Yoshino, Naoyuki; Taghizadeh-Hesary, Farhad

    2016-01-01

    In April 2013, the Bank of Japan (BOJ) introduced an inflation target of 2% with the aim of overcoming deflation and achieving sustainable economic growth. But due to lower international oil prices it was unable to achieve this target and was forced to take further measures. Hence, in February 2016, the BOJ adopted a negative interest rate policy by massively increasing the money supply through purchasing long-term Japanese government bonds (JGBs). The BOJ had previously only purchased short-...

  6. Affect influences false memories at encoding: evidence from recognition data.

    Science.gov (United States)

    Storbeck, Justin; Clore, Gerald L

    2011-08-01

    Memory is susceptible to illusions in the form of false memories. Prior research found, however, that sad moods reduce false memories. The current experiment had two goals: (1) to determine whether affect influences retrieval processes, and (2) to determine whether affect influences the strength and the persistence of false memories. Happy or sad moods were induced either before or after learning word lists designed to produce false memories. Control groups did not experience a mood induction. We found that sad moods reduced false memories only when induced before learning. Signal detection analyses confirmed that sad moods induced prior to learning reduced activation of nonpresented critical lures suggesting that they came to mind less often. Affective states, however, did not influence retrieval effects. We conclude that negative affective states promote item-specific processing, which reduces false memories in a similar way as using an explicitly guided cognitive control strategy. 2011 APA, all rights reserved

  7. Risk of breast cancer after false-positive results in mammographic screening.

    Science.gov (United States)

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  8. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  9. Individual differences in false memory from misinformation: cognitive factors.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Lin, Chongde; He, Qinghua; Chen, Chunhui; Li, He; Xue, Gui; Lu, Zhonglin; Dong, Qi

    2010-07-01

    This research investigated the cognitive correlates of false memories that are induced by the misinformation paradigm. A large sample of Chinese college students (N=436) participated in a misinformation procedure and also took a battery of cognitive tests. Results revealed sizable and systematic individual differences in false memory arising from exposure to misinformation. False memories were significantly and negatively correlated with measures of intelligence (measured with Raven's Advanced Progressive Matrices and Wechsler Adult Intelligence Scale), perception (Motor-Free Visual Perception Test, Change Blindness, and Tone Discrimination), memory (Wechsler Memory Scales and 2-back Working Memory tasks), and face judgement (Face Recognition and Facial Expression Recognition). These findings suggest that people with relatively low intelligence and poor perceptual abilities might be more susceptible to the misinformation effect.

  10. Effects of Maternal Negativity and of Early and Recent Recurrent Depressive Disorder on Children's False Belief Understanding

    Science.gov (United States)

    Rohrer, Lisa M.; Cicchetti, Dante; Rogosch, Fred A.; Toth, Sheree L.; Maughan, Angeline

    2011-01-01

    Research has shown that children of depressed mothers are at risk for problems in a variety of developmental domains; however, little is known about the effects of maternal depression on children's emerging understanding of false beliefs. In this study, 3 false belief tasks were administered to 5-year-old children whose mothers had either met…

  11. Is the truth in the details? Extended narratives help distinguishing false "memories" from false "reports".

    Science.gov (United States)

    Sjödén, Björn; Granhag, Pär Anders; Ost, James; Roos Af Hjelmsäter, Emma

    2009-06-01

    The present study examined the effects of fantasy proneness on false "reports" and false "memories", of existent and non-existent footage of a public event. We predicted that highly fantasy prone individuals would be more likely to stand by their initial claim of having seen a film of the event than low fantasy prone participants when prompted for more details about their experiences. Eighty creative arts students and 80 other students were asked whether they had seen CCTV footage preceding the attack on Swedish foreign minister Anna Lindh up to, and including, non-existent footage of the actual moment of the attack. If affirmative, they were probed for extended narratives of what they claimed to have seen. Overall, 64% of participants provided a false "report" by answering yes to the initial question. Of these, 30% provided no explicit details of the attack, and a further 15% retracted their initial answer in their narratives. This left 19% of the sample who appeared to have false "memories" because they provided explicit details of the actual moment of the attack. Women scored higher than men and art students scored higher than other students on fantasy proneness, but there was no effect on levels of false reporting or false "memory". Memories were rated more vivid and clear for existent compared to non-existent aspects of the event. In sum, these data suggest a more complex relationship between memory distortions and fantasy proneness than previously observed.

  12. New England observed and predicted July maximum negative stream/river temperature daily rate of change points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted July stream/river temperature maximum negative daily rate of change in New England based on a...

  13. Exposure reduces negative bias in self-rated performance in public speaking fearful participants.

    Science.gov (United States)

    Cheng, Joyce; Niles, Andrea N; Craske, Michelle G

    2017-03-01

    Individuals with public speaking anxiety (PSA) under-rate their performance compared to objective observers. The present study examined whether exposure reduces the discrepancy between self and observer performance ratings and improved observer-rated performance in individuals with PSA. PSA participants gave a speech in front of a small audience and rated their performance using a questionnaire before and after completing repeated exposures to public speaking. Non-anxious control participants gave a speech and completed the questionnaire one time only. Objective observers watched videos of the speeches and rated performance using the same questionnaire. PSA participants underrated their performance to a greater degree than did controls prior to exposure, but also performed significantly more poorly than did controls when rated objectively. Bias significantly decreased and objective-rated performance significantly increased following completion of exposure in PSA participants, and on one performance measure, anxious participants no longer showed a greater discrepancy between self and observer performance ratings compared to controls. The study employed non-clinical student sample, but the results should be replicated in clinical anxiety samples. These findings indicate that exposure alone significantly reduces negative performance bias among PSA individuals, but additional exposure or additional interventions may be necessary to fully correct bias and performance deficits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.

    Science.gov (United States)

    Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk

    2016-08-01

    Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.

  15. Confabulation versus experimentally induced false memories in Korsakoff patients.

    Science.gov (United States)

    Van Damme, Ilse; d'Ydewalle, Géry

    2010-09-01

    The present study focuses on both the clinical symptom of confabulation and experimentally induced false memories in patients suffering from Korsakoff's syndrome. Despite the vast amount of case studies of confabulating patients and studies investigating false memories in the Deese-Roediger-McDermott (DRM) paradigm, the nature of Korsakoff patients' confabulatory behaviour and its association with DRM false memories have been rarely examined. Hence, the first aim of the present study was to evaluate confabulatory responses in a large sample of chronic Korsakoff patients and matched controls by means of the Dalla Barba Confabulation Battery. Second, the association between (provoked) confabulation and the patients' DRM false recognition performance was investigated. Korsakoff patients mainly confabulated in response to questions about episodic memory and questions to which the answer was unknown. A positive association was obtained between confabulation and the tendency to accept unstudied distractor words as being old in the DRM paradigm. On the other hand, there was a negative association between confabulation and false recognition of critical lures. The latter could be attributed to the importance of strategic retrieval at delayed memory testing.

  16. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  17. Risk of breast cancer after false-positive results in mammographic screening

    DEFF Research Database (Denmark)

    Roman, Marta; Castells, Xavier; Hofvind, Solveig

    2016-01-01

    risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50–69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1......Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level.......4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93–2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77–1.96), whereas those who tested false-positive at third screening had a RR...

  18. Lexical association and false memory for words in two cultures.

    Science.gov (United States)

    Lee, Yuh-shiow; Chiang, Wen-Chi; Hung, Hsu-Ching

    2008-01-01

    This study examined the relationship between language experience and false memory produced by the DRM paradigm. The word lists used in Stadler, et al. (Memory & Cognition, 27, 494-500, 1999) were first translated into Chinese. False recall and false recognition for critical non-presented targets were then tested on a group of Chinese users. The average co-occurrence rate of the list word and the critical word was calculated based on two large Chinese corpuses. List-level analyses revealed that the correlation between the American and Taiwanese participants was significant only in false recognition. More importantly, the co-occurrence rate was significantly correlated with false recall and recognition of Taiwanese participants, and not of American participants. In addition, the backward association strength based on Nelson et al. (The University of South Florida word association, rhyme and word fragment norms, 1999) was significantly correlated with false recall of American participants and not of Taiwanese participants. Results are discussed in terms of the relationship between language experiences and lexical association in creating false memory for word lists.

  19. Bug hunting with false negatives

    NARCIS (Netherlands)

    Calamé, J.R.; Ioustinova, N.; Pol, van de J.C.; Sidorova, N.; Davies, J.; Gibbons, J.

    2007-01-01

    Safe data abstractions are widely used for verification purposes. Positive verification results can be transferred from the abstract to the concrete system. When a property is violated in the abstract system, one still has to check whether a concrete violation scenario exists. However, even when the

  20. Negative transfer of heart rate control following biofeedback training: a partial replication.

    Science.gov (United States)

    Steptoe, A; Macready, D

    1985-09-01

    Ability to raise and lower heart rate (HR) on instruction was tested before and after unidirectional biofeedback training in two groups of 10 male volunteers. Instructional control was assessed in 2-min trials before training, and after 5 and 10 biofeedback trials of increasing (Group I) and decreasing (Group D) HR. The magnitude of HR elevations produced by Group D diminished following training, while modifications in Group I were unchanged. This negative transfer effect is discussed in relation to whether voluntary speeding and slowing HR reflect distinct capacities.

  1. Characterisation of false-positive observations in botanical surveys

    Directory of Open Access Journals (Sweden)

    Quentin J. Groom

    2017-05-01

    Full Text Available Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify

  2. Emotional valence of stimuli modulates false recognition: Using a modified version of the simplified conjoint recognition paradigm.

    Science.gov (United States)

    Gong, Xianmin; Xiao, Hongrui; Wang, Dahua

    2016-11-01

    False recognition results from the interplay of multiple cognitive processes, including verbatim memory, gist memory, phantom recollection, and response bias. In the current study, we modified the simplified Conjoint Recognition (CR) paradigm to investigate the way in which the valence of emotional stimuli affects the cognitive process and behavioral outcome of false recognition. In Study 1, we examined the applicability of the modification to the simplified CR paradigm and model. Twenty-six undergraduate students (13 females, aged 21.00±2.30years) learned and recognized both the large and small categories of photo objects. The applicability of the paradigm and model was confirmed by a fair goodness-of-fit of the model to the observational data and by their competence in detecting the memory differences between the large- and small-category conditions. In Study 2, we recruited another sample of 29 undergraduate students (14 females, aged 22.60±2.74years) to learn and recognize the categories of photo objects that were emotionally provocative. The results showed that negative valence increased false recognition, particularly the rate of false "remember" responses, by facilitating phantom recollection; positive valence did not influence false recognition significantly though enhanced gist processing. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. False feedback and beliefs influence name recall in younger and older adults.

    Science.gov (United States)

    Strickland-Hughes, Carla M; West, Robin Lea; Smith, Kimberly A; Ebner, Natalie C

    2017-09-01

    Feedback is an important self-regulatory process that affects task effort and subsequent performance. Benefits of positive feedback for list recall have been explored in research on goals and feedback, but the effect of negative feedback on memory has rarely been studied. The current research extends knowledge of memory and feedback effects by investigating face-name association memory and by examining the potential mediation of feedback effects, in younger and older adults, through self-evaluative beliefs. Beliefs were assessed before and after name recognition and name recall testing. Repeated presentation of false positive feedback was compared to false negative feedback and a no feedback condition. Results showed that memory self-efficacy declined over time for participants in the negative and no feedback conditions but was sustained for those receiving positive feedback. Furthermore, participants who received negative feedback felt older after testing than before testing. For name recall, the positive feedback group outperformed the negative feedback and no feedback groups combined, with no age interactions. The observed feedback-related effects on memory were fully mediated by changes in memory self-efficacy. These findings advance our understanding of how beliefs are related to feedback in memory and inform future studies examining the importance of self-regulation in memory.

  4. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  5. False Advertising

    OpenAIRE

    Rhodes, Andrew; Wilson, Chris M

    2016-01-01

    There is widespread evidence that some firms use false advertising to overstate the value of their products. We consider a model in which a policymaker is able to punish such false claims. We characterize an equilibrium where false advertising actively influences rational buyers, and analyze the effects of policy under different welfare objectives. We establish precise conditions where policy optimally permits a positive level of false advertising, and show how these conditions vary intuitive...

  6. Cues of High and Low Body Weight Negatively Influence Adults' Perceptions and Ratings in the Hypothetical Adoption Paradigm

    Directory of Open Access Journals (Sweden)

    Anthony A. Volk

    2006-01-01

    Full Text Available Infant and child facial cues influence perceptions and ratings in the Hypothetical Adoption Paradigm as well as actual parental care. A previous study demonstrated that infant and child facial cues of low body weight negatively influenced adults' ratings. The current study sought to replicate and expand on those results by presenting adults with normal faces as well as faces that were digitally altered to display high or low body weight. Cues of abnormal body weight significantly, and negatively, influenced adults’ ratings of adoption preference, health, and cuteness. Effect sizes were larger for cues of high body weight. Thus, infant and child facial cues of abnormal body weight may represent a relative risk factor to the quality of adult care obtained by children with abnormal body weight.

  7. The False Consensus Bias as Applied to Psychologically Disturbed Adolescents.

    Science.gov (United States)

    Range, Lillian M.; And Others

    1991-01-01

    Twelve adolescents who described themselves as depressed or suicidal and 43 nondisturbed adolescents read article about child's suicidal or viral illness death. Both groups viewed suicidal child and family more negatively than family and child with viral illness. Consistent with false consensus hypothesis, psychologically disturbed adolescents…

  8. The Influence of Feedback of Diagnosis and Executive Function Skills on Rates of False Positive and False Negative Outcomes for ADHD

    Science.gov (United States)

    Bender, Stacy L.; Privitera, Gregory J.

    2016-01-01

    This study examined executive function (EF) skills and self-reported symptoms of ADHD. EF skills were measured to determine whether skills were different between groups that reported clinical levels of ADHD symptoms (clinical group) and nonclinical levels of ADHD symptoms (nonclinical group). EF skills in the nonclinical group were also…

  9. Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2015-01-01

    We present a novel algorithm for classifying true and false alarms of five life-threatening arrhythmias in intensive care. This algorithm was entered in the PhysioNet/Computing in Cardiology Challenge 2015 Reducing False Arrhythmia Alarms in the ICU. The algorithm performs a binary classification of

  10. Development of False Memories in Bilingual Children and Adults

    Science.gov (United States)

    Howe, Mark L.; Gagnon, Nadine; Thouas, Lisa

    2008-01-01

    The effects of within- versus between-languages (English-French) study and test on rates of bilingual children's and adults' true and false memories were examined. Children aged 6 through 12 and university-aged adults participated in a standard Deese-Roediger-McDermott false memory task using free recall and recognition. Recall results showed…

  11. Differentiating true and false schematic memories in older adults.

    Science.gov (United States)

    Webb, Christina E; Dennis, Nancy A

    2018-02-06

    While schemas aid memory for schematically related information, the gist induced by the schema can also lead to high rates of false memories, especially in older adults. The neural mechanisms that support and differentiate true and false memories in aging are not well understood. The current study sought to clarify this, using a novel scene paradigm to investigate the role of schemas on true and false memories in older adults. Healthy older adults encoded schematic scenes (e.g., bathroom). At retrieval, participants were tested on their memory for both schematic and non-schematic targets and lures while fMRI data was collected. Results indicate that true memories were supported by the typical retrieval network, and activity in this network was greater for true than false memories. Schema specific retrieval was supported by mPFC, extending this common finding to aging. While no region differentiated false memories compared to correct rejections, results showed that individual differences in false memory rates were associated with variability in neural activity. The findings underscore the importance of elucidating the neural basis of cognition within older adults, as well as the specific contribution of individual differences to the neural basis of memory errors in aging. © The Author(s) 2018. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Effect of False Confidence on Asset Allocation Decisions of Households

    Directory of Open Access Journals (Sweden)

    Swarn Chatterjee

    2014-01-01

    Full Text Available This paper investigates whether false confidence, as characterized by a high level of personal mastery and a low level of intelligence (IQ, results in frequent investor trading and subsequent investor wealth erosion across time. Using the National Longitudinal Survey (NLSY79, change in wealth and asset allocation across time is modeled as a function of various behavioral, socio-economic and demographic variables drawn from prior literature.  Findings of this research reveal that false confidence is indeed a predictor of trading activity in individual investment assets, and it also has a negative impact on individual wealth creation across time.

  13. The ADRA2B gene in the production of false memories for affective information in healthy female volunteers.

    Science.gov (United States)

    Fairfield, Beth; Mammarella, Nicola; Di Domenico, Alberto; D'Aurora, Marco; Stuppia, Liborio; Gatta, Valentina

    2017-08-30

    False memories are common memory distortions in everyday life and seem to increase with affectively connoted complex information. In line with recent studies showing a significant interaction between the noradrenergic system and emotional memory, we investigated whether healthy volunteer carriers of the deletion variant of the ADRA2B gene that codes for the α2b-adrenergic receptor are more prone to false memories than non-carriers. In this study, we collected genotype data from 212 healthy female volunteers; 91 ADRA2B carriers and 121 non-carriers. To assess gene effects on false memories for affective information, factorial mixed model analysis of variances (ANOVAs) were conducted with genotype as the between-subjects factor and type of memory error as the within-subjects factor. We found that although carriers and non-carriers made comparable numbers of false memory errors, they showed differences in the direction of valence biases, especially for inferential causal errors. Specifically, carriers produced fewer causal false memory errors for scripts with a negative outcome, whereas non-carriers showed a more general emotional effect and made fewer causal errors with both positive and negative outcomes. These findings suggest that putatively higher levels of noradrenaline in deletion carriers may enhance short-term consolidation of negative information and lead to fewer memory distortions when facing negative events. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Acute effects of triazolam on false recognition.

    Science.gov (United States)

    Mintzer, M Z; Griffiths, R R

    2000-12-01

    Neuropsychological, neuroimaging, and electrophysiological techniques have been applied to the study of false recognition; however, psychopharmacological techniques have not been applied. Benzodiazepine sedative/anxiolytic drugs produce memory deficits similar to those observed in organic amnesia and may be useful tools for studying normal and abnormal memory mechanisms. The present double-blind, placebo-controlled repeated measures study examined the acute effects of orally administered triazolam (Halcion; 0.125 and 0.25 mg/70 kg), a benzodiazepine hypnotic, on performance in the Deese (1959)/Roediger-McDermott (1995) false recognition paradigm in 24 healthy volunteers. Paralleling previous demonstrations in amnesic patients, triazolam produced significant dose-related reductions in false recognition rates to nonstudied words associatively related to studied words, suggesting that false recognition relies on normal memory mechanisms impaired in benzodiazepine-induced amnesia. The results also suggested that relative to placebo, triazolam reduced participants' reliance on memory for item-specific versus list-common semantic information and reduced participants' use of remember versus know responses.

  15. Serum albumin and globulin analysis for hepatocellular carcinoma detection avoiding false-negative results from alpha-fetoprotein test negative subjects

    Science.gov (United States)

    Wang, Jing; Feng, Shangyuan; Lin, Juqiang; Zeng, Yongyi; Li, Ling; Huang, Zufang; Li, Buhong; Zeng, Haishan; Chen, Rong

    2013-11-01

    Surface-enhanced Raman spectroscopy (SERS) of serum albumin and globulin were employed to detect hepatocellular carcinoma (HCC). Tentative assignments of SERS bands show specific biomolecular changes associated with cancer development. These changes include a decrease in relative amounts of tryptophan, glutamine, glycine, and serine, indicating excessive consumption of amino acids for protein duplication. Principal component analysis was also introduced to analyze the obtained spectra, resulting in both diagnostic sensitivity and specificity of 100%. More importantly, it reveals that this method can detect HCC patients with alpha-fetoprotein negative test results, suggesting its great potential as a new alternative to detect HCC.

  16. Proactive and Retroactive Effects of Negative Suggestion

    Science.gov (United States)

    Brown, Alan S.; Brown, Christine M.; Mosbacher, Joy L.; Dryden, W. Erich

    2006-01-01

    The negative effects of false information presented either prior to (proactive interference; PI) or following (retroactive interference; RI) true information was examined with word definitions (Experiment 1) and trivia facts (Experiment 2). Participants were explicitly aware of which information was true and false when shown, and true-false…

  17. False-vacuum decay in generalized extended inflation

    International Nuclear Information System (INIS)

    Holman, R.; Wang Yun; Kolb, E.W.; Chicago Univ., IL; Chicago Univ., IL; Vadas, S.L.

    1990-01-01

    We study false-vacuum decay in the context of generalized extended inflationary theories, and compute the bubble nucleation rates for these theories in the limit of G N →0. We find that the time dependence of the nucleation rate can be exponentially strong through the time dependence of the Jordan-Brans-Dicke field. This can have a pronounced effect on whether extended inflation can be succesfully implemented. (orig.)

  18. 7 CFR 275.13 - Review of negative cases.

    Science.gov (United States)

    2010-01-01

    ... State systems, the review date for negative cases could be the date of the agency's decision to deny... household which was listed incorrectly in the negative frame. (f) Demonstration projects/SSA processing. A... 7 Agriculture 4 2010-01-01 2010-01-01 false Review of negative cases. 275.13 Section 275.13...

  19. Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    Science.gov (United States)

    Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing

    2016-08-01

    False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2.

  20. 7 CFR 996.11 - Negative aflatoxin content.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Negative aflatoxin content. 996.11 Section 996.11 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... aflatoxin content. Negative aflatoxin content means 15 parts per billion (ppb) or less for peanuts that have...

  1. The spread of true and false news online.

    Science.gov (United States)

    Vosoughi, Soroush; Roy, Deb; Aral, Sinan

    2018-03-09

    We investigated the differential diffusion of all of the verified true and false news stories distributed on Twitter from 2006 to 2017. The data comprise ~126,000 stories tweeted by ~3 million people more than 4.5 million times. We classified news as true or false using information from six independent fact-checking organizations that exhibited 95 to 98% agreement on the classifications. Falsehood diffused significantly farther, faster, deeper, and more broadly than the truth in all categories of information, and the effects were more pronounced for false political news than for false news about terrorism, natural disasters, science, urban legends, or financial information. We found that false news was more novel than true news, which suggests that people were more likely to share novel information. Whereas false stories inspired fear, disgust, and surprise in replies, true stories inspired anticipation, sadness, joy, and trust. Contrary to conventional wisdom, robots accelerated the spread of true and false news at the same rate, implying that false news spreads more than the truth because humans, not robots, are more likely to spread it. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  2. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  3. The role of decision criterion in the Deese-Roediger-McDermott (DRM) false recognition memory: False memory falls and rises as a function of restriction on criterion setting.

    Science.gov (United States)

    Jou, Jerwen; Escamilla, Eric E; Arredondo, Mario L; Pena, Liann; Zuniga, Richard; Perez, Martin; Garcia, Clarissa

    2018-02-01

    How much of the Deese-Roediger-McDermott (DRM) false memory is attributable to decision criterion is so far a controversial issue. Previous studies typically used explicit warnings against accepting the critical lure to investigate this issue. The assumption is that if the false memory results from using a liberally biased criterion, it should be greatly reduced or eliminated by an explicit warning against accepting the critical lure. Results showed that warning was generally ineffective. We asked the question of whether subjects can substantially reduce false recognition without being warned when the test forces them to make a distinction between true and false memories. Using a two-alternative forced choice in which criterion plays a relatively smaller role, we showed that subjects could indeed greatly reduce the rate of false recognition. However, when the forced-choice restriction was removed from the two-item choice test, the rate of false recognition rebounded to that of the hit for studied list words, indicating the role of criterion in false recognition.

  4. [Neuropsychological study of false memory in patients with amnesia mild cognitive impairment].

    Science.gov (United States)

    Xie, Dan-dan; Cheng, Huai-dong; Yin, Chang-lin; Lü, Xin-yi; Wang, Kai

    2011-01-18

    To explore the profile of false memory in aMCI (amnesia mild cognitive impairment) and to elucidate the neuropsychological mechanism of false memory. False memory provoked by pictures and feeling-of-knowing (FOK) test in episodic memory (EM) were conducted in 25 aMCI patients at our hospital from October 2009 to May 2010. And 25 age and education level-matched healthy patients were recruited into the healthy control (HC) group. As compared with HC group, the rate of false memory was higher in the aMCI group. The rate of false memory in recall stage was 26% ± 7% and that of questionnaire stage 28% ± 12%. And the difference between two group was significant (t = 14.437, 7.597, P false recognition in the aMCI group (41% ± 10%) was higher than the HC group. And the difference was significant (t = 4.207, P false memory in recall and questionnaire stages were positively correlated with FOK-EM in aMCI group (r = 0.563, 0.705, P false memory provoked by pictures. The deficit of memory monitoring in aMCI may be the foundation of false memory.

  5. Marijuana usage in relation to harmfulness ratings, perceived likelihood of negative consequences, and defense mechanisms in high school students.

    Science.gov (United States)

    Como-Lesko, N; Primavera, L H; Szeszko, P R

    1994-08-01

    This study investigated high school students' marijuana usage patterns in relation to their harmfulness ratings of 15 licit and illicit drugs, perceived negative consequences from using marijuana, and types of defense mechanisms employed. Subjects were classified into one of five pattern-of-use groups based on marijuana usage: principled nonusers, nonusers, light users, moderate users, and heavy users. Principled nonusers (individuals who have never used marijuana and would not do so if it was legalized) rated marijuana, hashish, cocaine, and alcohol as significantly more harmful than heavy users. A cluster analysis of the drugs' harmfulness ratings best fit a three cluster solution and were named medicinal drugs, recreational drugs, and hard drugs. In general, principled nonusers rated negative consequences from using marijuana as significantly more likely to occur than other groups. Principled nonusers and heavy users utilized reversal from the Defense Mechanism Inventory, which includes repression and denial, significantly more than nonusers, indicating some trait common to the two extreme pattern-of-use groups.

  6. Detection of exudates in fundus imagery using a constant false-alarm rate (CFAR) detector

    Science.gov (United States)

    Khanna, Manish; Kapoor, Elina

    2014-05-01

    Diabetic retinopathy is the leading cause of blindness in adults in the United States. The presence of exudates in fundus imagery is the early sign of diabetic retinopathy so detection of these lesions is essential in preventing further ocular damage. In this paper we present a novel technique to automatically detect exudates in fundus imagery that is robust against spatial and temporal variations of background noise. The detection threshold is adjusted dynamically, based on the local noise statics around the pixel under test in order to maintain a pre-determined, constant false alarm rate (CFAR). The CFAR detector is often used to detect bright targets in radar imagery where the background clutter can vary considerably from scene to scene and with angle to the scene. Similarly, the CFAR detector addresses the challenge of detecting exudate lesions in RGB and multispectral fundus imagery where the background clutter often exhibits variations in brightness and texture. These variations present a challenge to common, global thresholding detection algorithms and other methods. Performance of the CFAR algorithm is tested against a publicly available, annotated, diabetic retinopathy database and preliminary testing suggests that performance of the CFAR detector proves to be superior to techniques such as Otsu thresholding.

  7. Pyrosequencing as a tool for the detection of Phytophthora species: error rate and risk of false Molecular Operational Taxonomic Units.

    Science.gov (United States)

    Vettraino, A M; Bonants, P; Tomassini, A; Bruni, N; Vannini, A

    2012-11-01

    To evaluate the accuracy of pyrosequencing for the description of Phytophthora communities in terms of taxa identification and risk of assignment for false Molecular Operational Taxonomic Units (MOTUs). Pyrosequencing of Internal Transcribed Spacer 1 (ITS1) amplicons was used to describe the structure of a DNA mixture comprising eight Phytophthora spp. and Pythium vexans. Pyrosequencing resulted in 16 965 reads, detecting all species in the template DNA mixture. Reducing the ITS1 sequence identity threshold resulted in a decrease in numbers of unmatched reads but a concomitant increase in the numbers of false MOTUs. The total error rate was 0·63% and comprised mainly mismatches (0·25%) Pyrosequencing of ITS1 region is an efficient and accurate technique for the detection and identification of Phytophthora spp. in environmental samples. However, the risk of allocating false MOTUs, even when demonstrated to be low, may require additional validation with alternative detection methods. Phytophthora spp. are considered among the most destructive groups of invasive plant pathogens, affecting thousands of cultivated and wild plants worldwide. Simultaneous early detection of Phytophthora complexes in environmental samples offers an unique opportunity for the interception of known and unknown species along pathways of introduction, along with the identification of these organisms in invaded environments. © 2012 The Authors Letters in Applied Microbiology © 2012 The Society for Applied Microbiology.

  8. Voting experiments: Bandwagon voting or false-consensus effect?

    OpenAIRE

    Ivo Bischoff; Henrik Egbert

    2008-01-01

    In an experiment designed to test for expressive voting, Tyran (JPubEc 2004) found a strong positive correlation between the participants' approval for a proposal to donate money for charity and their expected approval rate for fellow voters. This phenomenon can be due to bandwagon voting or a false consensus effect. The social science literature reports both effects for voting decisions. Replicating Tyran's experiment and adding new treatments, we provide evidence for a false consensus effec...

  9. Cross-cultural patterns in dynamic ratings of positive and negative natural emotional behaviour.

    Science.gov (United States)

    Sneddon, Ian; McKeown, Gary; McRorie, Margaret; Vukicevic, Tijana

    2011-02-18

    Studies of cross-cultural variations in the perception of emotion have typically compared rates of recognition of static posed stimulus photographs. That research has provided evidence for universality in the recognition of a range of emotions but also for some systematic cross-cultural variation in the interpretation of emotional expression. However, questions remain about how widely such findings can be generalised to real life emotional situations. The present study provides the first evidence that the previously reported interplay between universal and cultural influences extends to ratings of natural, dynamic emotional stimuli. Participants from Northern Ireland, Serbia, Guatemala and Peru used a computer based tool to continuously rate the strength of positive and negative emotion being displayed in twelve short video sequences by people from the United Kingdom engaged in emotional conversations. Generalized additive mixed models were developed to assess the differences in perception of emotion between countries and sexes. Our results indicate that the temporal pattern of ratings is similar across cultures for a range of emotions and social contexts. However, there are systematic differences in intensity ratings between the countries, with participants from Northern Ireland making the most extreme ratings in the majority of the clips. The results indicate that there is strong agreement across cultures in the valence and patterns of ratings of natural emotional situations but that participants from different cultures show systematic variation in the intensity with which they rate emotion. Results are discussed in terms of both 'in-group advantage' and 'display rules' approaches. This study indicates that examples of natural spontaneous emotional behaviour can be used to study cross-cultural variations in the perception of emotion.

  10. Cross-cultural patterns in dynamic ratings of positive and negative natural emotional behaviour.

    Directory of Open Access Journals (Sweden)

    Ian Sneddon

    2011-02-01

    Full Text Available Studies of cross-cultural variations in the perception of emotion have typically compared rates of recognition of static posed stimulus photographs. That research has provided evidence for universality in the recognition of a range of emotions but also for some systematic cross-cultural variation in the interpretation of emotional expression. However, questions remain about how widely such findings can be generalised to real life emotional situations. The present study provides the first evidence that the previously reported interplay between universal and cultural influences extends to ratings of natural, dynamic emotional stimuli.Participants from Northern Ireland, Serbia, Guatemala and Peru used a computer based tool to continuously rate the strength of positive and negative emotion being displayed in twelve short video sequences by people from the United Kingdom engaged in emotional conversations. Generalized additive mixed models were developed to assess the differences in perception of emotion between countries and sexes. Our results indicate that the temporal pattern of ratings is similar across cultures for a range of emotions and social contexts. However, there are systematic differences in intensity ratings between the countries, with participants from Northern Ireland making the most extreme ratings in the majority of the clips.The results indicate that there is strong agreement across cultures in the valence and patterns of ratings of natural emotional situations but that participants from different cultures show systematic variation in the intensity with which they rate emotion. Results are discussed in terms of both 'in-group advantage' and 'display rules' approaches. This study indicates that examples of natural spontaneous emotional behaviour can be used to study cross-cultural variations in the perception of emotion.

  11. Arousal?But Not Valence?Reduces False Memories at Retrieval

    OpenAIRE

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood indu...

  12. No effect of stress on false recognition.

    Science.gov (United States)

    Beato, María Soledad; Cadavid, Sara; Pulido, Ramón F; Pinho, María Salomé

    2013-02-01

    The present study aimed to analyze the effect of acute stress on false recognition in the Deese/Roediger-McDermott (DRM) paradigm. In this paradigm, lists of words associated with a non-presented critical lure are studied and, in a subsequent memory test, critical lures are often falsely remembered. In two experiments, participants were randomly assigned to either the stress group (Trier Social Stress Test) or the no-stress control group. Because we sought to control the level-of-processing at encoding, in Experiment 1, participants created a visual mental image for each presented word (deep encoding). In Experiment 2, participants performed a shallow encoding (to respond whether each word contained the letter "o"). The results indicated that, in both experiments, as predicted, heart rate and STAI-S scores increased only in the stress group. However, false recognition did not differ across stress and no-stress groups. Results suggest that, although psychosocial stress was successfully induced, it does not enhance the vulnerability of individuals with acute stress to DRM false recognition, regardless of the level of processing.

  13. Developmental Differences across Middle Childhood in Memory and Suggestibility for Negative and Positive Events.

    Science.gov (United States)

    Paz-Alonso, Pedro M; Goodman, Gail S

    2016-01-01

    In the present study, we investigated age differences in children's eyewitness memory and suggestibility for negative and positive events that children often experience during middle childhood. We first examined 216 ratings by children aged 8-12 years of the frequency and intensity of personal negative and positive experiences (Study 1). Based on those ratings, videotapes depicting the most frequent and intense negative (an accident) and positive (a family excursion) events were developed. A new sample of 227 children aged 8-12 years was tested for recognition memory of the videotapes using the three-stage post-event misinformation procedure (Study 2). Compared with 8- to 9-year-olds, 10- to 12-year-olds exhibited less memory malleability and less compliance with false information. Age improvements in recognition accuracy were also evident for children who watched the negative event, but not for those who watched the positive event. Compliance predicted misinformation effects, particularly in regard to peripheral details. Thus, using ecologically representative emotional events, age differences in suggestibility and memory accuracy emerged, especially for negative events.Theoretical and forensic implications concerning children's eyewitness memory and suggestibility are discussed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.

    2015-01-01

    Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID

  15. Sample size calculation for comparing two negative binomial rates.

    Science.gov (United States)

    Zhu, Haiyuan; Lakkis, Hassan

    2014-02-10

    Negative binomial model has been increasingly used to model the count data in recent clinical trials. It is frequently chosen over Poisson model in cases of overdispersed count data that are commonly seen in clinical trials. One of the challenges of applying negative binomial model in clinical trial design is the sample size estimation. In practice, simulation methods have been frequently used for sample size estimation. In this paper, an explicit formula is developed to calculate sample size based on the negative binomial model. Depending on different approaches to estimate the variance under null hypothesis, three variations of the sample size formula are proposed and discussed. Important characteristics of the formula include its accuracy and its ability to explicitly incorporate dispersion parameter and exposure time. The performance of the formula with each variation is assessed using simulations. Copyright © 2013 John Wiley & Sons, Ltd.

  16. Decay rate of the false vacuum at high temperatures

    International Nuclear Information System (INIS)

    Eboli, O.J.P.; Marques, G.C.

    1986-01-01

    We investigate, within the semiclassical approach, the high temperature behaviour of the decay rate (Γ) of the metastable vacuum in Field Theory. We exhibit some exactly soluble (1+1) and (3+1) dimensional examples and develop a formal expression for γ in the high temperature limit. (Author) [pt

  17. Reactions to perceived fairness: The impact of mortality salience and self-esteem on ratings of negative affect

    NARCIS (Netherlands)

    Bos, K. van den

    2001-01-01

    In correspondence with terror management theory, the findings of two experiments show that reminders of death lead to stronger effects of perceived fairness on ratings of negative affect. Furthermore, in line with the theory''s self-esteem mechanism, results of Experiment 1 suggest that state

  18. [Effects of false memories on the Concealed Information Test].

    Science.gov (United States)

    Zaitsu, Wataru

    2012-10-01

    The effects of false memories on polygraph examinations with the Concealed Information Test (CIT) were investigated by using the Deese-Roediger-McDermott (DRM) paradigm, which allows participants to evoke false memories. Physiological responses to questions consisting of learned, lure, and unlearned items were measured and recorded. The results indicated that responses to lure questions showed critical responses to questions about learned items. These responses included repression of respiration, an increase in electrodermal activity, and a drop in heart rate. These results suggest that critical response patterns are generated in the peripheral nervous system by true and false memories.

  19. Manifold adaptation for constant false alarm rate ship detection in South African oceans

    CSIR Research Space (South Africa)

    Schwegmann, CP

    2015-04-01

    Full Text Available prescreening method. It uses a scalar threshold value to determine how bright a pixel needs to be in order to be classified as a ship and thus inversely how many false alarms are permitted. This paper presents by a method of converting the scalar threshold...

  20. High resistance rate against 15 different antibiotics in aerobic gram-negative bacteria isolates of cardiology intensive care unit patients

    Directory of Open Access Journals (Sweden)

    Küçükates E

    2002-01-01

    Full Text Available Aerobic gram negative bacteria were isolated and examined microbiologically from various clinical samples of 602 patients hospitalized between January 1997 and December 2000 in surgical and coronary intensive care units (ICUs. A total of 827 isolates were obtained from 602 patients. The majority of microorganisms were isolated from the respiratory tract (50.3% and blood (39.9%. Pseudomonas spp. were the most frequently isolated gram negative species (32.7%, followed by Acinetobacter spp. (24.0% and Klebsiella pneumoniae (19.4%. High resistance rates to all antibiotics studied were observed. Imipenem and meropenem were the most effective antibiotics against gram negatives.

  1. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis

    DEFF Research Database (Denmark)

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian

    2016-01-01

    outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction...... of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each...... new trial. For each false positive, we performed TSA, using three different approaches. RESULTS: We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta...

  2. Emotion and false memory: How goal-irrelevance can be relevant for what people remember

    OpenAIRE

    Van Damme, I; Kaplan, RL; Levine, LJ; Loftus, EF

    2017-01-01

    Elaborating on misleading information concerning emotional events can lead people to form false memories. The present experiment compared participants' susceptibility to false memories when they elaborated on information associated with positive versus negative emotion and pregoal versus postgoal emotion. Pregoal emotion reflects appraisals that goal attainment or failure is anticipated but has not yet occurred (e.g., hope and fear). Postgoal emotion reflects appraisals that goal attainment o...

  3. Diagnostic miss rate for colorectal cancer: an audit.

    Science.gov (United States)

    Than, Mary; Witherspoon, Jolene; Shami, Javed; Patil, Prachi; Saklani, Avanish

    2015-01-01

    Colorectal cancer (CRC) is a common cancer worldwide. While screening improves survival, avoiding delayed diagnosis in symptomatic patients is crucial. Computed tomographic colonography (CTC) or colonoscopy is recommended as first-line investigation and most societies recommend counseling patients undergoing colonoscopy about a miss rate of 5%. This audit evaluates "miss rate" of colorectal investigations, which have led to diagnostic delay in symptomatic cases in a district general hospital in the United Kingdom. This is a retrospective review of 150 consecutive CRC cases presenting between August 2010 and July 2011. Evidence of bowel investigations done in the 3 years prior to diagnosis was obtained from computerized health records. Data regarding previous bowel investigations such as colonoscopy, CTC, double contrast barium enema (DCBE), and CT abdomen/pelvis were collected. 6.7% cases were identified via screening pathway while 93% were identified through symptomatic pathway. 17% (26/150) of newly diagnosed CRC had been investigated in the preceding 3 years. Of these, 8% (12/150) had false negative results. The false negative rate for CRC diagnosis was 3.5% for colonoscopy (3/85), 6.7% for CTC (1/17), 9.4% for CT (5/53), and 26.7% for DCBE (4/15). Some patients had a missed diagnosis despite more than one diagnostic test. Time delay to diagnosis ranged from 21-456 days. 17% of patients diagnosed with CRC had been investigated in the previous 3 years. Higher miss rate of barium enema should preclude its use as a first-line modality to investigate CRC.

  4. 21 CFR 868.5935 - External negative pressure ventilator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External negative pressure ventilator. 868.5935 Section 868.5935 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... ventilator. (a) Identification. An external negative pressure ventilator (e.g., iron lung, cuirass) is a...

  5. Creating Memories for False Autobiographical Events in Childhood: A Systematic Review

    Science.gov (United States)

    Andrews, Bernice

    2016-01-01

    Summary Using a framework that distinguishes autobiographical belief, recollective experience, and confidence in memory, we review three major paradigms used to suggest false childhood events to adults: imagination inflation, false feedback and memory implantation. Imagination inflation and false feedback studies increase the belief that a suggested event occurred by a small amount such that events are still thought unlikely to have happened. In memory implantation studies, some recollective experience for the suggested events is induced on average in 47% of participants, but only in 15% are these experiences likely to be rated as full memories. We conclude that susceptibility to false memories of childhood events appears more limited than has been suggested. The data emphasise the complex judgements involved in distinguishing real from imaginary recollections and caution against accepting investigator‐based ratings as necessarily corresponding to participants' self‐reports. Recommendations are made for presenting the results of these studies in courtroom settings. © 2016 The Authors Applied Cognitive Psychology Published by John Wiley & Sons Ltd. PMID:28163368

  6. False memories, but not false beliefs, affect implicit attitudes for food preferences.

    Science.gov (United States)

    Howe, David; Anderson, Rachel J; Dewhurst, Stephen A

    2017-09-01

    Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. False vacuum decay in Jordan-Brans-Dicke cosmologies

    International Nuclear Information System (INIS)

    Holman, R.; Wang, Yun; Weinberg, E.J.

    1989-12-01

    We examine the bubble nucleation rate in a first-order phase transition taking place in a background Jordan-Brans-Dicke cosmology. We compute the leading order terms in the nucleation rate when the Jordan-Brans-Dicke field is large (i.e., late times) by means of a Weyl rescaling of the fields in the theory. We find that despite the fact that the Jordan-Brans-Dicke field (hence the effective gravitational constant) has a time dependence in the false vacuum, at late times the nucleation rate is time independent. 21 refs

  8. Low local recurrence rate without postmastectomy radiation in node-negative breast cancer patients with tumors 5 cm and larger

    International Nuclear Information System (INIS)

    Floyd, Scott R.; Buchholz, Thomas A.; Haffty, Bruce G.; Goldberg, Saveli; Niemierko, Andrzej; Raad, Rita Abi; Oswald, Mary J.; Sullivan, Timothy; Strom, Eric A.; Powell, Simon N.; Katz, Angela; Taghian, Alphonse G.

    2006-01-01

    Purpose: To assess the need for adjuvant radiotherapy following mastectomy for patients with node-negative breast tumors 5 cm or larger. Methods and Materials: Between 1981 and 2002, a total of 70 patients with node-negative breast cancer and tumors 5 cm or larger were treated with mastectomy and adjuvant systemic therapies but without radiotherapy at three institutions. We retrospectively assessed rates and risk factors for locoregional failure (LRF), overall survival (OS), and disease-free survival (DFS) in these patients. Results: With a median follow-up of 85 months, the 5-year actuarial LRF rate was 7.6% (95% confidence interval, 3%-16%). LRF was primarily in the chest wall (4/5 local failures), and lymphatic-vascular invasion (LVI) was statistically significantly associated with LRF risk by the log-rank test (p = 0.017) and in Cox proportional hazards analysis (p 0.038). The 5-year OS and DFS rates were 83% and 86% respectively. LVI was also significantly associated with OS and DFS in both univariate and multivariate analysis. Conclusions: This series demonstrates a low LRF rate of 7.6% among breast cancer patients with node-negative tumors 5 cm and larger after mastectomy and adjuvant systemic therapy. Our data indicate that further adjuvant radiation therapy to increase local control may not be indicated by tumor size alone in the absence of positive lymph nodes. LVI was significantly associated with LRF in our series, indicating that patients with this risk factor require careful consideration with regard to further local therapy

  9. Addressing False Positives in Early Reading Assessment Using Intervention Response Data

    Science.gov (United States)

    McAlenney, Athena Lentini; Coyne, Michael D.

    2015-01-01

    The current study examined a solution to high false positive reading risk classification rates in early kindergarten by investigating a method of identifying students with possible false positive risk classifications and returning them to general classroom instruction. Researchers assessed kindergarten students (N = 105) identified as at risk who…

  10. Factors associated with negative T-SPOT.TB results among smear-negative tuberculosis patients in China.

    Science.gov (United States)

    Kang, Wanli; Wu, Meiying; Yang, Kunyun; Ertai, A; Wu, Shucai; Geng, Shujun; Li, Zhihui; Li, Mingwu; Pang, Yu; Tang, Shenjie

    2018-03-09

    We compared the positive rates of T-SPOT.TB and bacterial culture in the smear-negative PTB, and analyzed the factors affecting the results of negative T-SPOT.TB and bacterial culture. Retrospective evaluation of data from smear-negative PTB patients who underwent T-SPOT.TB and bacterial culture were done. The agreement and concordance were analyzed between T-SPOT.TB and bacterial culture. Multivariable logistic regression analysis was used to explore the factors associated with positive results of T-SPOT.TB and bacterial culture in smear-negative PTB. 858 eligible smear-negative PTB patients were included in the study. The agreement rate was 25.6% (22.7~28.5%) between T-SPOT.TB and bacterial culture in smear- negative PTB patients. The positive rate of T-SPOT.TB was higher than that of bacterial culture in smear-negative PTB patients (p SPOT.TB and bacterial culture (p > 0.05). Using multivariable logistic regression analysis we found that older age ≥ 60 years (OR = 0.469, 95% CI: 0.287-0.768) and decreased albumin (OR = 0.614, 95% CI: 0.380-0.992) were associated with negative diagnostic results of T-SPOT.TB in smear-negative PTB patients. Female (OR = 0.654, 95% CI: 0.431-0.992) were associated with negative diagnostic results of bacteria culture in smear-negative PTB patients. Our results indicated that the older age and decreased albumin were independently associated with negative T-SPOT.TB responses.

  11. The 4-Item Negative Symptom Assessment (NSA-4) Instrument: A Simple Tool for Evaluating Negative Symptoms in Schizophrenia Following Brief Training.

    Science.gov (United States)

    Alphs, Larry; Morlock, Robert; Coon, Cheryl; van Willigenburg, Arjen; Panagides, John

    2010-07-01

    Objective. To assess the ability of mental health professionals to use the 4-item Negative Symptom Assessment instrument, derived from the Negative Symptom Assessment-16, to rapidly determine the severity of negative symptoms of schizophrenia.Design. Open participation.Setting. Medical education conferences.Participants. Attendees at two international psychiatry conferences.Measurements. Participants read a brief set of the 4-item Negative Symptom Assessment instructions and viewed a videotape of a patient with schizophrenia. Using the 1 to 6 4-item Negative Symptom Assessment severity rating scale, they rated four negative symptom items and the overall global negative symptoms. These ratings were compared with a consensus rating determination using frequency distributions and Chi-square tests for the proportion of participant ratings that were within one point of the expert rating.Results. More than 400 medical professionals (293 physicians, 50% with a European practice, and 55% who reported past utilization of schizophrenia ratings scales) participated. Between 82.1 and 91.1 percent of the 4-items and the global rating determinations by the participants were within one rating point of the consensus expert ratings. The differences between the percentage of participant rating scores that were within one point versus the percentage that were greater than one point different from those by the consensus experts was significant (pnegative symptoms using the 4-item Negative Symptom Assessment did not generally differ among the geographic regions of practice, the professional credentialing, or their familiarity with the use of schizophrenia symptom rating instruments.Conclusion. These findings suggest that clinicians from a variety of geographic practices can, after brief training, use the 4-item Negative Symptom Assessment effectively to rapidly assess negative symptoms in patients with schizophrenia.

  12. Emotionally Negative Pictures Enhance Gist Memory

    OpenAIRE

    Bookbinder, S. H.; Brainerd, C. J.

    2016-01-01

    In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are due to valence and which are due to arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively-valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling reve...

  13. Exercise thallium-201 scintigraphy and prognosis in typical angina pectoris and negative exercise electrocardiography

    International Nuclear Information System (INIS)

    Bairey, C.N.; Rozanski, A.; Maddahi, J.; Resser, K.J.; Berman, D.S.

    1989-01-01

    Patients with a history of typical angina but negative exercise electrocardiography represent a subgroup with an intermediate likelihood of having coronary artery disease and future cardiac events. A retrospective study of the prognostic utility of stress-redistribution thallium-201 scintigraphy was performed in 190 such patients. A second group of 203 patients with typical angina and a positive exercise electrocardiogram were analyzed for comparative scintigraphic purposes. The cardiac event rate for the 144 negative exercise electrocardiogram patients with normal thallium results was 5 vs 15% in the 46 patients with abnormal thallium results (p = 0.01). These patients were further stratified into high (14 to 18%), intermediate (9%) and low (less than 2%) risk groups for future cardiac events based on combining the thallium results with the percentage of maximal predicted heart rate achieved. A multivariate analysis revealed that an abnormal thallium result was the only significant correlate of future cardiac events. Mechanisms responsible for the discordant finding of a negative exercise electrocardiogram in patients with typical angina include (1) false-positive angina symptomatology in low prevalence coronary artery disease groups in whom the thallium test is negative, and (2) electrocardiographically silent ischemia in patients in whom the thallium test is positive. These findings reveal that thallium stress-redistribution scintigraphy can be used to stratify 1-year prognosis in this subgroup of patients with typical angina and negative exercise electrocardiograms

  14. Improving sensitivity in proteome studies by analysis of false discovery rates for multiple search engines.

    Science.gov (United States)

    Jones, Andrew R; Siepen, Jennifer A; Hubbard, Simon J; Paton, Norman W

    2009-03-01

    LC-MS experiments can generate large quantities of data, for which a variety of database search engines are available to make peptide and protein identifications. Decoy databases are becoming widely used to place statistical confidence in result sets, allowing the false discovery rate (FDR) to be estimated. Different search engines produce different identification sets so employing more than one search engine could result in an increased number of peptides (and proteins) being identified, if an appropriate mechanism for combining data can be defined. We have developed a search engine independent score, based on FDR, which allows peptide identifications from different search engines to be combined, called the FDR Score. The results demonstrate that the observed FDR is significantly different when analysing the set of identifications made by all three search engines, by each pair of search engines or by a single search engine. Our algorithm assigns identifications to groups according to the set of search engines that have made the identification, and re-assigns the score (combined FDR Score). The combined FDR Score can differentiate between correct and incorrect peptide identifications with high accuracy, allowing on average 35% more peptide identifications to be made at a fixed FDR than using a single search engine.

  15. False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.

    Science.gov (United States)

    Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed

    2017-10-01

    To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.

  16. False-negative type-specific glycoprotein G antibody responses in STI clinic patients with recurrent HSV-1 or HSV-2 DNA positive genital herpes, The Netherlands.

    Science.gov (United States)

    van Rooijen, Martijn S; Roest, Wim; Hansen, Gino; Kwa, David; de Vries, Henry J C

    2016-06-01

    Herpes simplex virus (HSV) type-discriminating antibody tests (glycoprotein G (gG) directed) are used to identify naïve persons and differentiate acute infections from recurrences. We studied test characteristics of three commercially available antibody tests in patients with recurrent (established by viral PCR tests) herpes simplex virus type 1 (HSV-1) or herpes simplex virus type 2 (HSV-2) genital herpes episodes. Serum samples (at minimum 3 months after t=0) were examined for the presence of gG-1-specific or gG-2-specific antibodies using the HerpeSelect 1 and 2 Immunoblot IgG, the HerpeSelect 1 and 2 enzyme linked immunoassays IgG and the LIAISON HSV-1 and HSV-2 IgG indirect chemiluminescence immunoassays. The immunoblot was HSV-1 positive in 70.6% (95% CI 44.0% to 89.7%), the LIAISON in 88.2% (95% CI 63.5% to 98.5%) and the ELISA in 82.4% (95% CI 56.6% to 96.2%) of the 17 patients with a recurrent HSV-1 episode. From 33 patients with a recurrent HSV-2 episode, the immunoblot was HSV-2 positive in 84.8% (95% CI 68.1% to 94.9%), the LIAISON in 69.7% (95% CI 51.3% to 84.4%) and the ELISA in 84.8% (95% CI 68.1% to 94.9%). Among 15/17 (88.2%; 95% CI 63.5% to 98.5%) patients with HSV-1 and 30/33 (90.1%; 95% CI 75.7% to 98.1%) patients with HSV-2, HSV-1 or HSV-2 antibodies, respectively, were detected in at least one of the three antibody tests. Commercial type-specific gG HSV-1 or HSV-2 antibody assays were false negative in 12-30% of patients with recurrent HSV-1 or HSV-2 DNA positive genital lesions. The clinical and epidemiological use of type-specific HSV serology can be hampered by false-negative results, especially if based on a single test. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    Energy Technology Data Exchange (ETDEWEB)

    Itatani, R., E-mail: banguliao@gmail.com [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Namimoto, T. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Atsuji, S.; Katahira, K.; Morishita, S. [Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitani, K.; Hamada, Y. [Department of Urology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitaoka, M. [Department of Pathology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Nakaura, T. [Department of Diagnostic Radiology, Amakusa Medical Center, Kameba 854-1, Amakusa, Kumamoto 863-0046 (Japan); Yamashita, Y. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan)

    2014-10-15

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy.

  18. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    International Nuclear Information System (INIS)

    Itatani, R.; Namimoto, T.; Atsuji, S.; Katahira, K.; Morishita, S.; Kitani, K.; Hamada, Y.; Kitaoka, M.; Nakaura, T.; Yamashita, Y.

    2014-01-01

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy

  19. Decay rate of the false vacuum at high tempratures

    International Nuclear Information System (INIS)

    Eboli, O.J.P.; Marques, G.C.

    1984-01-01

    Within the semiclassical approach, the high temperaure behaviour of the decay rate of the metastable vacuum in Field Theory is investigated. It is shown that, contrarily to what has been proposed in the literature, the pre-exponential factor exhibits a nontrivial dependence on the temperature. Furthermore, this dependence is such that at very high temperatures it is as important as the exponential factor and consequently it spoils many conclusions drawn up to now on Cosmological Phase Transitions. (Author) [pt

  20. Experimental Effects of Acute Exercise on Prospective Memory and False Memory.

    Science.gov (United States)

    Green, David; Loprinzi, Paul D

    2018-01-01

    Research demonstrates that acute exercise can enhance retrospective episodic memory performance. However, limited research has examined the effects of acute exercise on prospective memory, and no studies have examined the effects of exercise on false memory performance. This study examined the potential effects of acute exercise on prospective memory and false memory performance. A between-group randomized controlled trial was employed, with participants (college students; M age  = 20 years) randomized into an exercise group (15-minute acute bout of treadmill walking; N = 25) or a control group (15 minutes of sitting; N = 26). Prospective memory was assessed from two laboratory and two naturalistic assessments outside the lab. False memory was assessed using a word-list trial. There were no statistically significant differences in prospective memory based on group allocation (F Group×Time  = 1.17; P = 0.32; η 2  = 0.06). However, the control group recalled more false words and had a higher rate of false memory recognition (F Group×Time  = 3.15; P = 0.01; η 2  = 0.26). These findings indicate that acute moderate-intensity aerobic exercise is not associated with prospective memory performance but provides some suggestive evidence that acute exercise may reduce the rate of false memories.

  1. Sample Size Calculation for Controlling False Discovery Proportion

    Directory of Open Access Journals (Sweden)

    Shulian Shang

    2012-01-01

    Full Text Available The false discovery proportion (FDP, the proportion of incorrect rejections among all rejections, is a direct measure of abundance of false positive findings in multiple testing. Many methods have been proposed to control FDP, but they are too conservative to be useful for power analysis. Study designs for controlling the mean of FDP, which is false discovery rate, have been commonly used. However, there has been little attempt to design study with direct FDP control to achieve certain level of efficiency. We provide a sample size calculation method using the variance formula of the FDP under weak-dependence assumptions to achieve the desired overall power. The relationship between design parameters and sample size is explored. The adequacy of the procedure is assessed by simulation. We illustrate the method using estimated correlations from a prostate cancer dataset.

  2. Undermining belief in false memories leads to less efficient problem-solving behaviour.

    Science.gov (United States)

    Wang, Jianqin; Otgaar, Henry; Howe, Mark L; Smeets, Tom; Merckelbach, Harald; Nahouli, Zacharia

    2017-08-01

    Memories of events for which the belief in the occurrence of those events is undermined, but recollection is retained, are called nonbelieved memories (NBMs). The present experiments examined the effects of NBMs on subsequent problem-solving behaviour. In Experiment 1, we challenged participants' beliefs in their memories and examined whether NBMs affected subsequent solution rates on insight-based problems. True and false memories were elicited using the Deese/Roediger-McDermott (DRM) paradigm. Then participants' belief in true and false memories was challenged by telling them the item had not been presented. We found that when the challenge led to undermining belief in false memories, fewer problems were solved than when belief was not challenged. In Experiment 2, a similar procedure was used except that some participants solved the problems one week rather than immediately after the feedback. Again, our results showed that undermining belief in false memories resulted in lower problem solution rates. These findings suggest that for false memories, belief is an important agent in whether memories serve as effective primes for immediate and delayed problem-solving.

  3. Emotional false memories in children with learning disabilities.

    Science.gov (United States)

    Mirandola, Chiara; Losito, Nunzia; Ghetti, Simona; Cornoldi, Cesare

    2014-02-01

    Research has shown that children with learning disabilities (LD) are less prone to evince associative illusions of memory as a result of impairments in their ability to engage in semantic processing. However, it is unclear whether this observation is true for scripted life events, especially if they include emotional content, or across a broad spectrum of learning disabilities. The present study addressed these issues by assessing recognition memory for script-like information in children with nonverbal learning disability (NLD), children with dyslexia, and typically developing children (N=51). Participants viewed photographs about 8 common events (e.g., family dinner), and embedded in each episode was either a negative or a neutral consequence of an unseen action. Children's memory was then tested on a yes/no recognition task that included old and new photographs. Results showed that the three groups performed similarly in recognizing target photographs, but exhibited differences in memory errors. Compared to other groups, children with NLD were more likely to falsely recognize photographs that depicted an unseen cause of an emotional seen event and associated more "Remember" responses to these errors. Children with dyslexia were equally likely to falsely recognize both unseen causes of seen photographs and photographs generally consistent with the script, whereas the other participant groups were more likely to falsely recognize unseen causes rather than script-consistent distractors. Results are interpreted in terms of mechanisms underlying false memories' formation in different clinical populations of children with LD. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Misleading Measurements: How Ohio School Ratings Foster False Comparisons. Executive Summary

    Science.gov (United States)

    DePaoli, Jennifer

    2014-01-01

    Policy Matters Ohio looked at schools rated the highest over a two-year period in each of Ohio's eight largest urban districts. State, school, and district data were used to examine schools--district-run and charter--that were rated Excellent or higher for either the 2010-11 or the 2011-12 school year or both. The number of schools examined ranged…

  5. Intact suppression of increased false recognition in schizophrenia.

    Science.gov (United States)

    Weiss, Anthony P; Dodson, Chad S; Goff, Donald C; Schacter, Daniel L; Heckers, Stephan

    2002-09-01

    Recognition memory is impaired in patients with schizophrenia, as they rely largely on item familiarity, rather than conscious recollection, to make mnemonic decisions. False recognition of novel items (foils) is increased in schizophrenia and may relate to this deficit in conscious recollection. By studying pictures of the target word during encoding, healthy adults can suppress false recognition. This study examined the effect of pictorial encoding on subsequent recognition of repeated foils in patients with schizophrenia. The study included 40 patients with schizophrenia and 32 healthy comparison subjects. After incidental encoding of 60 words or pictures, subjects were tested for recognition of target items intermixed with 60 new foils. These new foils were subsequently repeated following either a two- or 24-word delay. Subjects were instructed to label these repeated foils as new and not to mistake them for old target words. Schizophrenic patients showed greater overall false recognition of repeated foils. The rate of false recognition of repeated foils was lower after picture encoding than after word encoding. Despite higher levels of false recognition of repeated new items, patients and comparison subjects demonstrated a similar degree of false recognition suppression after picture, as compared to word, encoding. Patients with schizophrenia displayed greater false recognition of repeated foils than comparison subjects, suggesting both a decrement of item- (or source-) specific recollection and a consequent reliance on familiarity in schizophrenia. Despite these deficits, presenting pictorial information at encoding allowed schizophrenic subjects to suppress false recognition to a similar degree as the comparison group, implying the intact use of a high-level cognitive strategy in this population.

  6. Annual Papanicolaou screening for 5 years among human papillomavirus-negative women

    International Nuclear Information System (INIS)

    Petry, Karl Ulrich; Rinnau, Franziska; Böhmer, Gerd; Hollwitz, Bettina; Luyten, Alexander; Buttmann, Nina; Brünger, Martin; Iftner, Thomas

    2013-01-01

    Primary human papilloma virus (HPV) screening is more effective than cytology in reducing the risk of cervical cancer, but screening intervals should be extended in HPV-negative women. However, some Markov models predicted that long intervals are associated with an excess risk of cervical cancer. The aim of this analysis was to estimate the real-life risks and benefits of annual Papanicolaou (Pap) screening in HPV-negative women with normal cytology. Women with negative Hybrid Capture 2 (HC2) results and normal cytology at the time of inclusion in the Hannover HPV screening trial underwent annual Pap smears for 5 years. A subgroup was randomly selected for retesting with cytology, HC2, and colposcopy 60–68 months after recruitment. Of 4236 women included, 3406 had at least one Pap smear, but only 1185 attended all five annual screening visits. The proportion of women with at least one abnormal smear was 14.4% in 60 months. The probability of abnormal smears increased continuously over time. No case of ≥ CIN2+ was observed during 5 years. Of 605 women selected for subgroup analysis, 292 agreed to be retested (48.3%). The rate of high-risk HPV at 60–68 months was 3.0% (9/296). The long-term risk of high-grade neoplasia after an initial negative HC2 test and normal cytology result was low, while the rate of false-positive abnormal Pap smears was significant and increased constantly over time. Pap smear screening of HPV-negative women more frequently than every 5 years could be potentially harmful and seems to be of little clinical value

  7. Serotonin transporter binding in the hypothalamus correlates negatively with tonic heat pain ratings in healthy subjects: A [11C]DASB PET study

    DEFF Research Database (Denmark)

    Kupers, Ron; Frokjaer, Vibe G.; Erritzoe, David

    2010-01-01

    There is a large body of evidence that the serotonergic system plays an important role in the transmission and regulation of pain. Here we used positron emission tomography (PET) with the serotonin transporter (SERT) tracer [11C]DASB to study the relationship between SERT binding in the brain and....... The negative correlation between SERT binding in the hypothalamus and insula with tonic pain ratings suggests a possible serotonergic control of the role of these areas in the modulation or in the affective appreciation of pain.......) tonic noxious heat stimulus. PET data were analyzed using both volume-of-interest (VOI) and voxel-based approaches. VOI analysis revealed a significant negative correlation between tonic pain ratings and SERT binding in the hypothalamus (r = −0.59; p = 0.008), a finding confirmed by the parametric...... analysis. The parametric analysis also revealed a negative correlation between tonic pain ratings and SERT binding in the right anterior insula. Measures of regional SERT binding did not correlate with pain threshold or with responses to short phasic suprathreshold phasic heat stimuli. Finally, the VOI...

  8. Acute subarachnoid haemorrhage: Is a negative CT angiogram enough?

    International Nuclear Information System (INIS)

    MacKinnon, A.D.; Clifton, A.G.; Rich, P.M.

    2013-01-01

    Aim: To determine the negative predictive value of 16 channel multisection computed tomography angiography (CTA) for detecting aneurysms in spontaneous subarachnoid haemorrhage (SAH), using digital subtraction angiography (DSA) as the reference standard. Materials and methods: The prospectively collected cerebral angiogram database of Department of Neuroradiology, Atkinson Morley Regional Neuroscience Centre was used to identify 200 consecutive patients who had undergone DSA for SAH. Of these, 176 had undergone CTA prior to DSA. Clinical details and radiology reports were correlated and images of positive investigations reviewed. Results: DSA showed one or more cerebral aneurysms in 105 (60%) patients. These were correctly reported on CTA in 100. CTA was reported negative for aneurysms in 74 patients. Of these five were false negative and had aneurysms detected on DSA. In the CTA/DSA negative group, 11 (16%) patients had classical perimesencephalic clinical syndrome and blood distribution. There were two false positives at CTA. For ruptured cerebral aneurysms, CTA had 95.2% sensitivity, 97.2% specificity, 98.1% positive predictive value, and 93.2% negative predictive value. Conclusion: The sensitivity and negative predictive value of CTA for ruptured aneurysms remains imperfect. Continued use of DSA is recommended in most patients with a negative CTA after acute SAH. Confirmation of a negative CTA result with DSA may not be routinely required in patients with perimesencephalic syndrome

  9. Implementation of the Bacillus cereus microbiological plate used for the screening of tetracyclines in raw milk samples with STAR protocol - the problem with false-negative results solved.

    Science.gov (United States)

    Raspor Lainšček, P; Biasizzo, M; Henigman, U; Dolenc, J; Kirbiš, A

    2014-01-01

    In antibiotic residue analyses the first step of screening is just as important as the following steps. Screening methods need to be quick and inexpensive, but above all sensitive enough to detect the antibiotic residue at or below the maximum residue limit (MRL). In the case of a positive result, the next step is conducted and further methods are used for confirmation. MRLs stated in European Union Regulation 37/2010 for tetracyclines in raw milk are: 100 µg kg(-1) for tetracycline, 100 µg kg(-1) for oxytetracycline, 100 µg kg(-1) for chlortetracycline and no limit for doxycycline because it is prohibited for use in animals from which milk is produced for human consumption. The current five-plate microbiological screening method for the detection of antibiotic residues in raw milk was found to be simple and inexpensive, but not specific, sensitive and reliable enough to detect tetracycline at MRL in routine raw milk screening procedures. Spiking samples with tetracycline at the MRL level and applying them on Bacillus cereus ATCC 11778 microbiological plates often gave false-negative results, indicating that tetracyclines may have to be inactivated or masked. Tetracyclines seem to bind to a certain component in milk. Consequently, when applying samples to the B. cereus microbiological plate the antibiotic cannot inhibit the growth of B. cereus which disables the formation of inhibition zones on the test plate. After adding the appropriate amount of citric acid into the milk samples, we solved the problem of false-negative results. During the validation 79 samples of milk were spiked with tetracyclines at different concentrations: 100 µg kg(-1) for tetracycline, 100 µg kg(-1) for oxytetracycline, 80 µg kg(-1) for chlortetracycline and 30 µg kg(-1) for doxycycline. Concentrations used in the validation matched the requirements for MRLs (they were either at or below the MRLs) stated in European Union Regulation 37/2010. The sensitivity of the validation was 100%.

  10. Stress and emotional valence effects on children's versus adolescents' true and false memory.

    Science.gov (United States)

    Quas, Jodi A; Rush, Elizabeth B; Yim, Ilona S; Edelstein, Robin S; Otgaar, Henry; Smeets, Tom

    2016-01-01

    Despite considerable interest in understanding how stress influences memory accuracy and errors, particularly in children, methodological limitations have made it difficult to examine the effects of stress independent of the effects of the emotional valence of to-be-remembered information in developmental populations. In this study, we manipulated stress levels in 7-8- and 12-14-year-olds and then exposed them to negative, neutral, and positive word lists. Shortly afterward, we tested their recognition memory for the words and false memory for non-presented but related words. Adolescents in the high-stress condition were more accurate than those in the low-stress condition, while children's accuracy did not differ across stress conditions. Also, among adolescents, accuracy and errors were higher for the negative than positive words, while in children, word valence was unrelated to accuracy. Finally, increases in children's and adolescents' cortisol responses, especially in the high-stress condition, were related to greater accuracy but not false memories and only for positive emotional words. Findings suggest that stress at encoding, as well as the emotional content of to-be-remembered information, may influence memory in different ways across development, highlighting the need for greater complexity in existing models of true and false memory formation.

  11. Entropies of negative incomes, Pareto-distributed loss, and financial crises.

    Science.gov (United States)

    Gao, Jianbo; Hu, Jing; Mao, Xiang; Zhou, Mi; Gurbaxani, Brian; Lin, Johnny

    2011-01-01

    Health monitoring of world economy is an important issue, especially in a time of profound economic difficulty world-wide. The most important aspect of health monitoring is to accurately predict economic downturns. To gain insights into how economic crises develop, we present two metrics, positive and negative income entropy and distribution analysis, to analyze the collective "spatial" and temporal dynamics of companies in nine sectors of the world economy over a 19 year period from 1990-2008. These metrics provide accurate predictive skill with a very low false-positive rate in predicting downturns. The new metrics also provide evidence of phase transition-like behavior prior to the onset of recessions. Such a transition occurs when negative pretax incomes prior to or during economic recessions transition from a thin-tailed exponential distribution to the higher entropy Pareto distribution, and develop even heavier tails than those of the positive pretax incomes. These features propagate from the crisis initiating sector of the economy to other sectors.

  12. Entropies of negative incomes, Pareto-distributed loss, and financial crises.

    Directory of Open Access Journals (Sweden)

    Jianbo Gao

    Full Text Available Health monitoring of world economy is an important issue, especially in a time of profound economic difficulty world-wide. The most important aspect of health monitoring is to accurately predict economic downturns. To gain insights into how economic crises develop, we present two metrics, positive and negative income entropy and distribution analysis, to analyze the collective "spatial" and temporal dynamics of companies in nine sectors of the world economy over a 19 year period from 1990-2008. These metrics provide accurate predictive skill with a very low false-positive rate in predicting downturns. The new metrics also provide evidence of phase transition-like behavior prior to the onset of recessions. Such a transition occurs when negative pretax incomes prior to or during economic recessions transition from a thin-tailed exponential distribution to the higher entropy Pareto distribution, and develop even heavier tails than those of the positive pretax incomes. These features propagate from the crisis initiating sector of the economy to other sectors.

  13. True and false recall and dissociation among maltreated children: the role of self-schema.

    Science.gov (United States)

    Valentino, Kristin; Cicchetti, Dante; Rogosch, Fred A; Toth, Sheree L

    2008-01-01

    The current investigation addresses the manner through which trauma affects basic memory and self-system processes. True and false recall for self-referent stimuli were assessed in conjunction with dissociative symptomatology among abused (N=76), neglected (N=92), and nonmaltreated (N=116) school-aged children. Abused, neglected, and nonmaltreated children did not differ in the level of processing self-schema effect or in the occurrence and frequency of false recall. Rather, differences in the affective valence of false recall emerged as a function of maltreatment subtype and age. Regarding dissociation, the abused children displayed higher levels of dissociative symptomatology than did the nonmaltreated children. Although abused, neglected, and nonmaltreated children did not exhibit differences in the valence of their self-schemas, positive and negative self-schemas were related to self-integration differently among the subgroups of maltreatment. Negative self-schemas were associated with increased dissociation among the abused children, whereas positive self-schemas were related to increased dissociation for the neglected children. Thus, positive self-schemas displayed by the younger neglected children were related to higher dissociation, suggestive of defensive self-processing. Implications for clinical intervention are underscored.

  14. Training for assessment of negative symptoms of schizophrenia across languages and cultures: comparison of the NSA-16 with the PANSS Negative Subscale and Negative Symptom factor.

    Science.gov (United States)

    Daniel, David G; Alphs, Larry; Cazorla, Pilar; Bartko, John J; Panagides, John

    2011-07-01

    The 16-item Negative Symptom Assessment scale (NSA-16) has been validated in English-speaking raters. We analyzed the level of agreement achieved among raters of different nationalities using the NSA-16 and the Positive and Negative Syndrome Scale (PANSS) negative subscale and Marder negative factor. Raters participating in two international trials were trained in the use of each instrument through lectures and feedback on their ratings of at least one videotaped interview of a schizophrenic patient. Overall and regional (North America, Western Europe, Eastern Europe, South/Central America, and Australia and South Africa combined) kappa values were calculated and mean total scores were compared (1-way analysis of variance) by region for each instrument. In addition, within-scales variance was calculated by item to help identify negative symptoms that were particularly challenging to obtain agreement on across cultures. In the combined group of international raters, the kappa values for ratings of the NSA-16, PANSS negative subscale, and Marder negative factors were 0.89, 0.84, and 0.82, respectively. Kappa values calculated by geographic region ranged from 0.87 to 0.94 for the NSA-16 compared with 0.82 to 0.86 for the PANSS negative subscale and 0.79 to 0.87 for the PANSS Marder negative factor. Despite cultural and linguistic differences among raters, standardizing measurement of negative symptoms in international clinical trials is possible using available rating scales: NSA-16, PANSS negative subscale, and Marder negative subscale. Agreement among raters was at least as high using the NSA-16 as using the PANSS instruments.

  15. False memories to emotional stimuli are not equally affected in right- and left-brain-damaged stroke patients.

    Science.gov (United States)

    Buratto, Luciano Grüdtner; Zimmermann, Nicolle; Ferré, Perrine; Joanette, Yves; Fonseca, Rochele Paz; Stein, Lilian Milnitsky

    2014-10-01

    Previous research has attributed to the right hemisphere (RH) a key role in eliciting false memories to visual emotional stimuli. These results have been explained in terms of two right-hemisphere properties: (i) that emotional stimuli are preferentially processed in the RH and (ii) that visual stimuli are represented more coarsely in the RH. According to this account, false emotional memories are preferentially produced in the RH because emotional stimuli are both more strongly and more diffusely activated during encoding, leaving a memory trace that can be erroneously reactivated by similar but unstudied emotional items at test. If this right-hemisphere hypothesis is correct, then RH damage should result in a reduction in false memories to emotional stimuli relative to left-hemisphere lesions. To investigate this possibility, groups of right-brain-damaged (RBD, N=15), left-brain-damaged (LBD, N=15) and healthy (HC, N=30) participants took part in a recognition memory experiment with emotional (negative and positive) and non-emotional pictures. False memories were operationalized as incorrect responses to unstudied pictures that were similar to studied ones. Both RBD and LBD participants showed similar reductions in false memories for negative pictures relative to controls. For positive pictures, however, false memories were reduced only in RBD patients. The results provide only partial support for the right-hemisphere hypothesis and suggest that inter-hemispheric cooperation models may be necessary to fully account for false emotional memories. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  17. Development of SCAR marker specific to non-toxic Jatropha curcas L. and designing a novel multiplexing PCR along with nrDNA ITS primers to circumvent the false negative detection

    KAUST Repository

    Mastan, Shaik G.

    2011-05-10

    Jatropha curcas L., a multipurpose shrub, has acquired significant economic importance for its seed oil which can be converted to biodiesel an emerging alternative to petro-diesel. In addition to the commercial value, it is also having medicinal and even high nutritional value to use as animal fodder which is limited due to the toxicity. Development of molecular marker will enable to differentiate non-toxic from toxic variety of J. curcas in a mixed population and also for quality control since the toxic components of J. curcas has deleterious effect on animals. In the present study, the efforts were made to generate the specific SCAR marker for toxic and/or non-toxic J. curcas from RAPD markers. Among the markers specific for toxic and non-toxic varieties, four were selected, purified, cloned, sequenced, and designed primers out of which one set of primers NT-JC/SCAR I/OPQ15-F and R could able to discriminate the non-toxic with toxic Jatropha by giving expected 430 bp size amplification in non-toxic variety. Furthermore, novel multiplex PCR was designed using the nrDNA ITS primers to overcome the false negatives. Present work also demonstrates utility of the conserved regions of nrDNA coding genes in ruling out the artifacts in PCR-like false negatives frequently occur in SCAR due to various reasons. The specific SCAR markers generated in the present investigation will help to distinguish non-toxic from toxic varieties of J. curcas or vice versa, and isolated marker along with designed multiplex protocol has applications in quality control for selective cultivation of non-toxic variety and will also assist in breeding and molecular mapping studies. © 2011 Springer Science+Business Media, LLC.

  18. False-negative urine human chorionic gonadotropin in molar pregnancy: " The high-dose hook effect" !

    Directory of Open Access Journals (Sweden)

    Sujata Narendra Datti

    2015-01-01

    Full Text Available Failure to detect pregnancy in the emergency situations can have important consequences. These include missing of ectopic pregnancy (the leading cause of first-trimester pregnancy-related maternal death, administration of medications contraindicated in pregnancy, fetal radiation exposure, and medico legal problems. This in turn has led to the dictum to check for pregnancy in all women of child-bearing age group. Urine pregnancy (human chorionic gonadotropin [hCG] test is the commonly used test to rule out pregnancy and has been reported by Griffey et al. in their study to achieve 100% sensitivity and 99.2% specificity in a clinical setting, resulting in a positive predictive value of 98.3% and a negative predictive value of nearly 100%. However, the sensitivity is influenced not only by the quantity of β hCG but on its variants that vary with different weeks of pregnancy. β hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. In spite of its high sensitivity, in the presence of molar pregnancy that is associated with very high levels of β hCG it fails to detect the antigen (β hCG. This is explained by the phenomenon known as "high-dose hook effect" which further leads to delay in diagnosis and treatment. This can be overcome by dilution of the sample. In such cases, diagnosis will be made by serum β hCG and ultrasound (USG. Here, we present a case of gravida 2 para 1 living 1 with 2΍ months amenorrhea with bleeding p/v and pain abdomen of 20 days duration whose urine β hCG was repeatedly negative and diagnosis was made by serum β hCG and USG.

  19. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    Science.gov (United States)

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Are subjective memory problems related to suggestibility, compliance, false memories, and objective memory performance?

    Science.gov (United States)

    Van Bergen, Saskia; Jelicic, Marko; Merckelbach, Harald

    2009-01-01

    The relationship between subjective memory beliefs and suggestibility, compliance, false memories, and objective memory performance was studied in a community sample of young and middle-aged people (N = 142). We hypothesized that people with subjective memory problems would exhibit higher suggestibility and compliance levels and would be more susceptible to false recollections than those who are optimistic about their memory. In addition, we expected a discrepancy between subjective memory judgments and objective memory performance. We found that subjective memory judgments correlated significantly with compliance, with more negative memory judgments accompanying higher levels of compliance. Contrary to our expectation, subjective memory problems did not correlate with suggestibility or false recollections. Furthermore, participants were accurate in estimating their objective memory performance.

  1. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    Science.gov (United States)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  2. Sample size calculation while controlling false discovery rate for differential expression analysis with RNA-sequencing experiments.

    Science.gov (United States)

    Bi, Ran; Liu, Peng

    2016-03-31

    RNA-Sequencing (RNA-seq) experiments have been popularly applied to transcriptome studies in recent years. Such experiments are still relatively costly. As a result, RNA-seq experiments often employ a small number of replicates. Power analysis and sample size calculation are challenging in the context of differential expression analysis with RNA-seq data. One challenge is that there are no closed-form formulae to calculate power for the popularly applied tests for differential expression analysis. In addition, false discovery rate (FDR), instead of family-wise type I error rate, is controlled for the multiple testing error in RNA-seq data analysis. So far, there are very few proposals on sample size calculation for RNA-seq experiments. In this paper, we propose a procedure for sample size calculation while controlling FDR for RNA-seq experimental design. Our procedure is based on the weighted linear model analysis facilitated by the voom method which has been shown to have competitive performance in terms of power and FDR control for RNA-seq differential expression analysis. We derive a method that approximates the average power across the differentially expressed genes, and then calculate the sample size to achieve a desired average power while controlling FDR. Simulation results demonstrate that the actual power of several popularly applied tests for differential expression is achieved and is close to the desired power for RNA-seq data with sample size calculated based on our method. Our proposed method provides an efficient algorithm to calculate sample size while controlling FDR for RNA-seq experimental design. We also provide an R package ssizeRNA that implements our proposed method and can be downloaded from the Comprehensive R Archive Network ( http://cran.r-project.org ).

  3. Assessment of Metabolome Annotation Quality: A Method for Evaluating the False Discovery Rate of Elemental Composition Searches

    Science.gov (United States)

    Matsuda, Fumio; Shinbo, Yoko; Oikawa, Akira; Hirai, Masami Yokota; Fiehn, Oliver; Kanaya, Shigehiko; Saito, Kazuki

    2009-01-01

    Background In metabolomics researches using mass spectrometry (MS), systematic searching of high-resolution mass data against compound databases is often the first step of metabolite annotation to determine elemental compositions possessing similar theoretical mass numbers. However, incorrect hits derived from errors in mass analyses will be included in the results of elemental composition searches. To assess the quality of peak annotation information, a novel methodology for false discovery rates (FDR) evaluation is presented in this study. Based on the FDR analyses, several aspects of an elemental composition search, including setting a threshold, estimating FDR, and the types of elemental composition databases most reliable for searching are discussed. Methodology/Principal Findings The FDR can be determined from one measured value (i.e., the hit rate for search queries) and four parameters determined by Monte Carlo simulation. The results indicate that relatively high FDR values (30–50%) were obtained when searching time-of-flight (TOF)/MS data using the KNApSAcK and KEGG databases. In addition, searches against large all-in-one databases (e.g., PubChem) always produced unacceptable results (FDR >70%). The estimated FDRs suggest that the quality of search results can be improved not only by performing more accurate mass analysis but also by modifying the properties of the compound database. A theoretical analysis indicates that FDR could be improved by using compound database with smaller but higher completeness entries. Conclusions/Significance High accuracy mass analysis, such as Fourier transform (FT)-MS, is needed for reliable annotation (FDR metabolome data. PMID:19847304

  4. Strain hardening rate sensitivity and strain rate sensitivity in TWIP steels

    Energy Technology Data Exchange (ETDEWEB)

    Bintu, Alexandra [TEMA, Department of Mechanical Engineering, University of Aveiro, Campus Universitário de Santiago, 3810-193 (Portugal); Vincze, Gabriela, E-mail: gvincze@ua.pt [TEMA, Department of Mechanical Engineering, University of Aveiro, Campus Universitário de Santiago, 3810-193 (Portugal); Picu, Catalin R. [Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 (United States); Lopes, Augusto B. [CICECO, Department of Materials and Ceramic Engineering, University of Aveiro, Campus Universitário de Santiago, 3810-193 (Portugal); Grácio, Jose J. [TEMA, Department of Mechanical Engineering, University of Aveiro, Campus Universitário de Santiago, 3810-193 (Portugal); Barlat, Frederic [Materials Mechanics Laboratory, Graduate Institute of Ferrous Technology, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2015-04-01

    TWIP steels are materials with very high strength and exceptional strain hardening capability, parameters leading to large energy absorption before failure. However, TWIP steels also exhibit reduced (often negative) strain rate sensitivity (SRS) which limits the post-necking deformation. In this study we demonstrate for an austenitic TWIP steel with 18% Mn a strong dependence of the twinning rate on the strain rate, which results in negative strain hardening rate sensitivity (SHRS). The instantaneous component of SHRS is large and negative, while its transient is close to zero. The SRS is observed to decrease with strain, becoming negative for larger strains. Direct observations of the strain rate dependence of the twinning rate are made using electron microscopy and electron backscatter diffraction, which substantiate the proposed mechanism for the observed negative SHRS.

  5. Strain hardening rate sensitivity and strain rate sensitivity in TWIP steels

    International Nuclear Information System (INIS)

    Bintu, Alexandra; Vincze, Gabriela; Picu, Catalin R.; Lopes, Augusto B.; Grácio, Jose J.; Barlat, Frederic

    2015-01-01

    TWIP steels are materials with very high strength and exceptional strain hardening capability, parameters leading to large energy absorption before failure. However, TWIP steels also exhibit reduced (often negative) strain rate sensitivity (SRS) which limits the post-necking deformation. In this study we demonstrate for an austenitic TWIP steel with 18% Mn a strong dependence of the twinning rate on the strain rate, which results in negative strain hardening rate sensitivity (SHRS). The instantaneous component of SHRS is large and negative, while its transient is close to zero. The SRS is observed to decrease with strain, becoming negative for larger strains. Direct observations of the strain rate dependence of the twinning rate are made using electron microscopy and electron backscatter diffraction, which substantiate the proposed mechanism for the observed negative SHRS

  6. A mode of error: Immunoglobulin binding protein (a subset of anti-citrullinated proteins can cause false positive tuberculosis test results in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Maria Greenwald

    2017-12-01

    Full Text Available Citrullinated Immunoglobulin Binding Protein (BiP is a newly described autoimmune target in rheumatoid arthritis (RA, one of many cyclic citrullinated peptides(CCP or ACPA. BiP is over-expressed in RA patients causing T cell expansion and increased interferon levels during incubation for the QuantiFERON-Gold tuberculosis test (QFT-G TB. The QFT-G TB has never been validated where interferon is increased by underlying disease, as for example RA.Of ACPA-positive RA patients (n = 126, we found a 13% false-positive TB test rate by QFT-G TB. Despite subsequent biologic therapy for 3 years of all 126 RA patients, none showed evidence of TB without INH. Most of the false-positive RA patients after treatment with biologic therapy reverted to a negative QFT-G test. False TB tests correlated with ACPA level (p < 0.02.Three healthy women without arthritis or TB exposure had negative QFT-G TB. In vitro, all three tested positive every time for TB correlating to the dose of BiP or anti-BiP added, at 2 ug/ml, 5 ug/ml, 10 ug/ml, and 20 ug/ml.BiP naturally found in the majority of ACPA-positive RA patients can result in a false positive QFT-G TB. Subsequent undertreatment of RA, if biologic therapy is withheld, and overtreatment of presumed latent TB may harm patients. Keywords: Tuberculosis, IGRA, Rheumatoid arthritis, Interferon, Anti-citrullinated peptide antibody (ACPA, Immunoglobulin binding protein (BiP

  7. Veridical and False Pictorial Memory in Individuals with and without Mental Retardation

    Science.gov (United States)

    Carlin, Michael T.; Toglia, Michael P.; Wakeford, Yvonne; Jakway, Allison; Sullivan, Kate; Hasel, Lisa

    2008-01-01

    Veridical and false pictorial recognition were assessed in individuals with mental retardation; groups were matched for MA and CA. Pictures were viewed in either a generative or static format at acquisition. The individuals with mental retardation and those in the MA-matched group had higher rates of false memories for critical items and lower hit…

  8. Filing false vice reports: Distinguishing true from false allegations of rape

    NARCIS (Netherlands)

    de Zutter, A.; Horselenberg, R.; van Koppen, P.J.

    2017-01-01

    False allegations constitute a problem since they may cause harm. To study the difference between true and false allegations we used a quasi-experimental approach. In the control condition likely true allegations were retrieved from criminal files. The victims, all female, were between the ages of

  9. False recognition of facial expressions of emotion: causes and implications.

    Science.gov (United States)

    Fernández-Dols, José-Miguel; Carrera, Pilar; Barchard, Kimberly A; Gacitua, Marta

    2008-08-01

    This article examines the importance of semantic processes in the recognition of emotional expressions, through a series of three studies on false recognition. The first study found a high frequency of false recognition of prototypical expressions of emotion when participants viewed slides and video clips of nonprototypical fearful and happy expressions. The second study tested whether semantic processes caused false recognition. The authors found that participants made significantly higher error rates when asked to detect expressions that corresponded to semantic labels than when asked to detect visual stimuli. Finally, given that previous research reported that false memories are less prevalent in younger children, the third study tested whether false recognition of prototypical expressions increased with age. The authors found that 67% of eight- to nine-year-old children reported nonpresent prototypical expressions of fear in a fearful context, but only 40% of 6- to 7-year-old children did so. Taken together, these three studies demonstrate the importance of semantic processes in the detection and categorization of prototypical emotional expressions.

  10. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    Science.gov (United States)

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  11. False memories for aggressive acts.

    Science.gov (United States)

    Laney, Cara; Takarangi, Melanie K T

    2013-06-01

    Can people develop false memories for committing aggressive acts? How does this process compare to developing false memories for victimhood? In the current research we used a simple false feedback procedure to implant false memories for committing aggressive acts (causing a black eye or spreading malicious gossip) or for victimhood (receiving a black eye). We then compared these false memories to other subjects' true memories for equivalent events. False aggressive memories were all too easy to implant, particularly in the minds of individuals with a proclivity towards aggression. Once implanted, the false memories were indistinguishable from true memories for the same events, on several dimensions, including emotional content. Implications for aggression-related memory more generally as well as false confessions are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  13. Interaction of sleep and emotional content on the production of false memories.

    Science.gov (United States)

    McKeon, Shannon; Pace-Schott, Edward F; Spencer, Rebecca M C

    2012-01-01

    Sleep benefits veridical memories, resulting in superior recall relative to off-line intervals spent awake. Sleep also increases false memory recall in the Deese-Roediger-McDermott (DRM) paradigm. Given the suggestion that emotional veridical memories are prioritized for consolidation over sleep, here we examined whether emotion modulates sleep's effect on false memory formation. Participants listened to semantically related word lists lacking a critical lure representing each list's "gist." Free recall was tested after 12 hours containing sleep or wake. The Sleep group recalled more studied words than the Wake group but only for emotionally neutral lists. False memories of both negative and neutral critical lures were greater following sleep relative to wake. Morning and Evening control groups (20-minute delay) did not differ ruling out circadian accounts for these differences. These results support the adaptive function of sleep in both promoting the consolidation of veridical declarative memories and in extracting unifying aspects from memory details.

  14. Interaction of sleep and emotional content on the production of false memories.

    Directory of Open Access Journals (Sweden)

    Shannon McKeon

    Full Text Available Sleep benefits veridical memories, resulting in superior recall relative to off-line intervals spent awake. Sleep also increases false memory recall in the Deese-Roediger-McDermott (DRM paradigm. Given the suggestion that emotional veridical memories are prioritized for consolidation over sleep, here we examined whether emotion modulates sleep's effect on false memory formation. Participants listened to semantically related word lists lacking a critical lure representing each list's "gist." Free recall was tested after 12 hours containing sleep or wake. The Sleep group recalled more studied words than the Wake group but only for emotionally neutral lists. False memories of both negative and neutral critical lures were greater following sleep relative to wake. Morning and Evening control groups (20-minute delay did not differ ruling out circadian accounts for these differences. These results support the adaptive function of sleep in both promoting the consolidation of veridical declarative memories and in extracting unifying aspects from memory details.

  15. The clinicopathologic characteristics and prognostic significance of triple-negativity in node-negative breast cancer

    International Nuclear Information System (INIS)

    Rhee, Jiyoung; Kim, Tae-You; Han, Sae-Won; Oh, Do-Youn; Kim, Jee Hyun; Im, Seock-Ah; Han, Wonshik; Ae Park, In; Noh, Dong-Young; Bang, Yung-Jue

    2008-01-01

    Triple-negative (TN) breast cancer, which is defined as being negative for the estrogen receptor (ER), the progesterone receptor (PR), and the human epidermal growth factor receptor 2 (HER-2), represents a subset of breast cancer with different biologic behaviour. We investigated the clinicopathologic characteristics and prognostic indicators of lymph node-negative TN breast cancer. Medical records were reviewed from patients with node-negative breast cancer who underwent curative surgery at Seoul National University Hospital between Jan. 2000 and Jun. 2003. Clinicopathologic variables and clinical outcomes were evaluated. Among 683 patients included, 136 had TN breast cancer and 529 had non-TN breast cancer. TN breast cancer correlated with younger age (< 35 y, p = 0.003), and higher histologic and nuclear grade (p < 0.001). It also correlated with a molecular profile associated with biological aggressiveness: negative for bcl-2 expression (p < 0.001), positive for the epidermal growth factor receptor (p = 0.003), and a high level of p53 (p < 0.001) and Ki67 expression (p < 0.00). The relapse rates during the follow-up period (median, 56.8 months) were 14.7% for TN breast cancer and 6.6% for non-TN breast cancer (p = 0.004). Relapse free survival (RFS) was significantly shorter among patients with TN breast cancer compared with those with non-TN breast cancer (4-year RFS rate 85.5% vs. 94.2%, respectively; p = 0.001). On multivariate analysis, young age, close resection margin, and triple-negativity were independent predictors of shorter RFS. TN breast cancer had higher relapse rate and more aggressive clinicopathologic characteristics than non-TN in node-negative breast cancer. Thus, TN breast cancer should be integrated into the risk factor analysis for node-negative breast cancer

  16. Integrated Proteomic Pipeline Using Multiple Search Engines for a Proteogenomic Study with a Controlled Protein False Discovery Rate.

    Science.gov (United States)

    Park, Gun Wook; Hwang, Heeyoun; Kim, Kwang Hoe; Lee, Ju Yeon; Lee, Hyun Kyoung; Park, Ji Yeong; Ji, Eun Sun; Park, Sung-Kyu Robin; Yates, John R; Kwon, Kyung-Hoon; Park, Young Mok; Lee, Hyoung-Joo; Paik, Young-Ki; Kim, Jin Young; Yoo, Jong Shin

    2016-11-04

    In the Chromosome-Centric Human Proteome Project (C-HPP), false-positive identification by peptide spectrum matches (PSMs) after database searches is a major issue for proteogenomic studies using liquid-chromatography and mass-spectrometry-based large proteomic profiling. Here we developed a simple strategy for protein identification, with a controlled false discovery rate (FDR) at the protein level, using an integrated proteomic pipeline (IPP) that consists of four engrailed steps as follows. First, using three different search engines, SEQUEST, MASCOT, and MS-GF+, individual proteomic searches were performed against the neXtProt database. Second, the search results from the PSMs were combined using statistical evaluation tools including DTASelect and Percolator. Third, the peptide search scores were converted into E-scores normalized using an in-house program. Last, ProteinInferencer was used to filter the proteins containing two or more peptides with a controlled FDR of 1.0% at the protein level. Finally, we compared the performance of the IPP to a conventional proteomic pipeline (CPP) for protein identification using a controlled FDR of <1% at the protein level. Using the IPP, a total of 5756 proteins (vs 4453 using the CPP) including 477 alternative splicing variants (vs 182 using the CPP) were identified from human hippocampal tissue. In addition, a total of 10 missing proteins (vs 7 using the CPP) were identified with two or more unique peptides, and their tryptic peptides were validated using MS/MS spectral pattern from a repository database or their corresponding synthetic peptides. This study shows that the IPP effectively improved the identification of proteins, including alternative splicing variants and missing proteins, in human hippocampal tissues for the C-HPP. All RAW files used in this study were deposited in ProteomeXchange (PXD000395).

  17. ROTATION RATE DIFFERENCES OF POSITIVE AND NEGATIVE SOLAR MAGNETIC FIELDS BETWEEN ±60° LATITUDES

    Energy Technology Data Exchange (ETDEWEB)

    Shi, X. J.; Xie, J. L., E-mail: shixiangjun@ynao.ac.cn [Yunnan Observatories, Chinese Academy of Sciences, Kunming 650011 (China)

    2015-04-15

    Based on a cross-correlation analysis of the Carrington synoptic maps of solar photospheric magnetic fields from Carrington Rotations Nos. 1625 to 2135 (from 1975 February to 2013 March), the sidereal rotation rates of the positive and negative magnetic fields in the latitude range of ±60° are obtained, and the rotation rate differences between them are investigated. The time–latitude distribution of the rate differences is shown, which looks like a butterfly diagram at the low and middle latitudes. For comparison, the time–latitude distribution of the longitudinally averaged photospheric magnetic fields is shown. We conclude that the magnetic fields having the same polarity as the leading sunspots at a given hemisphere rotate faster than those exhibiting the opposite polarity at low and middle latitudes. However, at higher latitudes, the magnetic fields having the same polarity as the leading sunspots at a given hemisphere do not always rotate faster than those with the opposite polarity. Furthermore, the relationship between the rotation rate differences and solar magnetic fields is studied through a correlation analysis. Our result shows that the correlation coefficients between them reach maximum values at 13° (14°) latitude in the northern (southern) hemisphere, and change sign at 28° latitude in both hemispheres, then reach their minimum values at 58° (53°) latitude in the northern (southern) hemisphere.

  18. Selection of GP. Mur antigen-negative RBC for blood recipients with anti-'Mia ' records decreases transfusion reaction rates in Taiwan.

    Science.gov (United States)

    Yang, C-A; Lin, J-A; Chang, C-W; Wu, K-H; Yeh, S-P; Ho, C-M; Chang, J-G

    2016-10-01

    To evaluate the clinical significance of GP. Mur antigen-negative blood selection for transfusion in patients with anti-'Mi a ' records. The GP. Mur RBC phenotype is prevalent (7·3%) in Taiwan. Antibodies against GP. Mur (anti-'Mi a ') are identified in 1·24% of our population, and anti-'Mi a ' screening using GP. Mur RBC has been routine for Taiwan's blood banks. However, due to the lack of commercial antibodies, only cross-matching was used to prevent transfusion of GP. Mur-positive blood to patients with anti-'Mi a ' in most hospitals. There is still a risk of GP. Mur-positive RBC exposure and subsequent anti-'Mi a '-related transfusion reactions. Since February 2014, GP. Mur antigen-negative RBCs identified by reaction with anti-'Mi a '-positive serum were selected for blood recipients with anti-'Mi a ' records. The transfusion reactions between January 2013 and January 2014 were compared with those that occurred between February 2014 and July 2015. The transfusion reaction rate was significantly higher in anti-'Mi a '-positive blood recipients compared to total subjects receiving an RBC transfusion before GP. Mur-negative donor RBC selection. After antigen-negative RBC selection, the transfusion reaction frequency in subjects with anti-'Mi a ' became similar to total blood recipients. IgG form anti-'Mi a ' antibodies were present in all cases of probable anti-'Mi a '-related transfusion reactions. The time required for anti-'Mi a ' boosting after transfusion was around 4-21 days. Selection of GP. Mur-negative RBC for transfusion to patients with anti-'Mi a ' records could decrease the rate of transfusion reaction and antibody boosting. This procedure should be incorporated into blood bank routines in areas where anti-'Mi a ' is prevalent. © 2016 British Blood Transfusion Society.

  19. The Chances of Subsequent Cancer Detection in Patients with a PSA > 20 ng/ml and an Initial Negative Biopsy

    Directory of Open Access Journals (Sweden)

    Nadeem Shaida

    2009-01-01

    Full Text Available Transrectal ultrasound (TRUS–guided prostate biopsy is known to carry a significant false-negative rate, leading some patients to have multiple biopsies. We investigated cancer detection rates in patients with a PSA >20 ng/ml and a negative initial biopsy. We reviewed our database of 2396 TRUS-guided biopsies done between 1997 and 2002 in order to give a follow-up of at least 6 years. PSA, PSA density (PSAD, PSA velocity (PSAV, prostate volume, and DRE findings were analysed in relation to cancer status. Of the patients, 388 (16% had a PSA >20 ng/ml, including 99 (26% with benign biopsies. Of those, 67 were rebiopsied, including 19 (28% with cancer on the first rebiopsy and four (6% on further biopsies. PSAD, DRE, and volume significantly differed between rebiopsied patients with and without cancer (p 20 ng/ml and have an initial negative biopsy have a high chance of malignancy being detected on a second biopsy. However, if a second biopsy is also negative, then the chances of subsequent biopsies showing signs of cancer are very low if the DRE is normal and particularly if the PSAD is >0.35 ng/ml/cm3.

  20. The robustness of false memory for emotional pictures.

    Science.gov (United States)

    Bessette-Symons, Brandy A

    2018-02-01

    Emotional material is commonly reported to be more accurately recognised; however, there is substantial evidence of increased false alarm rates (FAR) for emotional material and several reports of stronger influences on response bias than accuracy. This pattern is more frequently reported for words than pictures. Research on the mechanisms underlying bias differences has mostly focused on word lists under short retention intervals. This article presents four series of experiments examining recognition memory for emotional pictures while varying arousal and the control over the content of the pictures at two retention intervals, and one study measuring the relatedness of the series picture sets. Under the shorter retention interval, emotion increased false alarms and reduced accuracy. Under the longer retention interval emotion increased hit rates and FAR, resulting in reduced accuracy and/or bias. At both retention intervals, the pattern of valence effects differed based on the arousal associated with the picture sets. Emotional pictures were found to be more related than neutral pictures in each set; however, the influence of relatedness alone does not provide an adequate explanation for all emotional differences. The results demonstrate substantial emotional differences in picture recognition that vary based on valence, arousal and retention interval.

  1. cn.MOPS: mixture of Poissons for discovering copy number variations in next-generation sequencing data with a low false discovery rate.

    Science.gov (United States)

    Klambauer, Günter; Schwarzbauer, Karin; Mayr, Andreas; Clevert, Djork-Arné; Mitterecker, Andreas; Bodenhofer, Ulrich; Hochreiter, Sepp

    2012-05-01

    Quantitative analyses of next-generation sequencing (NGS) data, such as the detection of copy number variations (CNVs), remain challenging. Current methods detect CNVs as changes in the depth of coverage along chromosomes. Technological or genomic variations in the depth of coverage thus lead to a high false discovery rate (FDR), even upon correction for GC content. In the context of association studies between CNVs and disease, a high FDR means many false CNVs, thereby decreasing the discovery power of the study after correction for multiple testing. We propose 'Copy Number estimation by a Mixture Of PoissonS' (cn.MOPS), a data processing pipeline for CNV detection in NGS data. In contrast to previous approaches, cn.MOPS incorporates modeling of depths of coverage across samples at each genomic position. Therefore, cn.MOPS is not affected by read count variations along chromosomes. Using a Bayesian approach, cn.MOPS decomposes variations in the depth of coverage across samples into integer copy numbers and noise by means of its mixture components and Poisson distributions, respectively. The noise estimate allows for reducing the FDR by filtering out detections having high noise that are likely to be false detections. We compared cn.MOPS with the five most popular methods for CNV detection in NGS data using four benchmark datasets: (i) simulated data, (ii) NGS data from a male HapMap individual with implanted CNVs from the X chromosome, (iii) data from HapMap individuals with known CNVs, (iv) high coverage data from the 1000 Genomes Project. cn.MOPS outperformed its five competitors in terms of precision (1-FDR) and recall for both gains and losses in all benchmark data sets. The software cn.MOPS is publicly available as an R package at http://www.bioinf.jku.at/software/cnmops/ and at Bioconductor.

  2. A false-alarm aware methodology to develop robust and efficient multi-scale infrared small target detection algorithm

    Science.gov (United States)

    Moradi, Saed; Moallem, Payman; Sabahi, Mohamad Farzan

    2018-03-01

    False alarm rate and detection rate are still two contradictory metrics for infrared small target detection in an infrared search and track system (IRST), despite the development of new detection algorithms. In certain circumstances, not detecting true targets is more tolerable than detecting false items as true targets. Hence, considering background clutter and detector noise as the sources of the false alarm in an IRST system, in this paper, a false alarm aware methodology is presented to reduce false alarm rate while the detection rate remains undegraded. To this end, advantages and disadvantages of each detection algorithm are investigated and the sources of the false alarms are determined. Two target detection algorithms having independent false alarm sources are chosen in a way that the disadvantages of the one algorithm can be compensated by the advantages of the other one. In this work, multi-scale average absolute gray difference (AAGD) and Laplacian of point spread function (LoPSF) are utilized as the cornerstones of the desired algorithm of the proposed methodology. After presenting a conceptual model for the desired algorithm, it is implemented through the most straightforward mechanism. The desired algorithm effectively suppresses background clutter and eliminates detector noise. Also, since the input images are processed through just four different scales, the desired algorithm has good capability for real-time implementation. Simulation results in term of signal to clutter ratio and background suppression factor on real and simulated images prove the effectiveness and the performance of the proposed methodology. Since the desired algorithm was developed based on independent false alarm sources, our proposed methodology is expandable to any pair of detection algorithms which have different false alarm sources.

  3. Social influence and mental routes to the production of authentic false memories and inauthentic false memories.

    Science.gov (United States)

    Wagner, Michael F; Skowronski, John J

    2017-05-01

    Two studies assessed the extent to which people incorporated false facts provided by bogus others into their own recognition memory reports, and how these false memory reports were affected by: (a) truth of the information in others' summaries supporting the false facts, (b) motivation to process stories and summaries, (c) source credibility, and (d) ease of remembering original facts. False memory report frequency increased when false facts in a summary were supported by true information and varied inversely with the ease with which original facts could be remembered. Results from a measure probing participants' memory perceptions suggest that some false memories are authentic: People sometimes lack awareness of both the incorporation of false facts into their memory reports and where the false facts came from. However, many false memories are inauthentic: Despite reporting a false memory, people sometimes retain knowledge of the original stimulus and/or the origin of false facts. Copyright © 2017. Published by Elsevier Inc.

  4. Negative Suction Drain Through a Mini Periareolar Incision for the Treatment of Lactational Breast Abscess Shortens Hospital Stay and Increases Breastfeeding Rates.

    Science.gov (United States)

    Wei, Jinli; Zhang, Jiaxin; Fu, Deyuan

    2016-06-01

    Although breast abscess is a serious uncommon complication of mastitis with high morbidity rate, there is a lack of high-quality randomized trial to demonstrate the best treatments. We reported a novel way of applying negative suction drain through a mini periareolar incision. We retrospectively analyzed and compared the clinical characteristics of 62 patients with lactational breast abscess in our department from August 2012 to April 2015. Thirty-two patients went through traditional incision and drainage (Group A) and 30 patients were placed on negative suction drain through mini periareolar incision (Group B). There is no significant difference between the two groups in terms of age, white blood cell (WBC) count, size of the abscess cavity, and positive rate of Staphylococcus aureus (SA) or methicillin-resistant Staphylococcus aureus (MRSA). Patients in Group B had a shorter hospitalized stay (p = 0.003) and had a higher rate of continuation of breastfeeding (p breast abscess and maintaining breastfeeding.

  5. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    Science.gov (United States)

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Novel stimuli are negative stimuli: evidence that negative affect is reduced in the mere exposure effect.

    Science.gov (United States)

    Robinson, Brent M; Elias, Lorin J

    2005-04-01

    Repeated exposure of a nonreinforced stimulus results in an increased preference for that stimulus, the mere exposure effect. The present study repeatedly presented positive, negative, and neutrally affective faces to 48 participants while they made judgments about the emotional expression. Participants then rated the likeability of novel neutrally expressive faces and some of these previously presented faces, this time in their neutral expression. Faces originally presented as happy were rated as the most likeable, followed by faces originally presented as neutral. Negative and novel faces were not rated significantly differently from each other. These findings support the notion that the increase in preference towards repeatedly presented stimuli is the result of the reduction in negative affect, consistent with the modified two-factor uncertainty-reduction model and classical conditioning model of the mere exposure effect.

  7. Neural Network Target Identification System for False Alarm Reduction

    Science.gov (United States)

    Ye, David; Edens, Weston; Lu, Thomas T.; Chao, Tien-Hsin

    2009-01-01

    A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feed forward back propagation neural network (NN) is then trained to classify each feature vector and remove false positives. This paper discusses the test of the system performance and parameter optimizations process which adapts the system to various targets and datasets. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar image dataset.

  8. The impact of sleep on true and false memory across long delays.

    Science.gov (United States)

    Pardilla-Delgado, Enmanuelle; Payne, Jessica D

    2017-01-01

    While the influence of sleep on memory has a long history, sleep's role in the formation of false memories is less clear. Moreover, virtually nothing is known about the development of false memories beyond delays of about 12h. Here, for the first time, we assess post-sleep development of true and false memories across longer delay intervals of 24 and 48h. Although technically a false memory, remembering information that is related to the theme, or gist, of an experience can be considered an adaptive process. Some evidence suggests that sleep, compared to a wake period, increases both true and gist-based false memories in the Deese-Roediger-McDermott (DRM) task, but not all studies have returned this result, and most studies cannot rule out the possibility that sleep is merely protecting the information from interference, as opposed to actively aiding its consolidation. Here, to equate amount of time spent awake and asleep across groups, we assess how the positioning of sleep relative to memory encoding impacts retention across longer delays of 24 and 48h. Participants encoded 16 DRM lists in the morning (WAKE 1st Groups) or evening (SLEEP 1st Groups), and were tested either 24 or 48h later at the same time of day. Results demonstrate that true memory is better when participants sleep soon after learning. Sleeping first also increased false memory, but only in low performers. Importantly, and similar to previous studies, we found a negative correlation between slow-wave sleep (SWS) and false memory, suggesting that SWS may be detrimental for semantic/gist processing. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Do emotional stimuli enhance or impede recall relative to neutral stimuli? An investigation of two "false memory" tasks.

    Science.gov (United States)

    Monds, Lauren A; Paterson, Helen M; Kemp, Richard I

    2017-09-01

    Many eyewitness memory situations involve negative and distressing events; however, many studies investigating "false memory" phenomena use neutral stimuli only. The aim of the present study was to determine how both the Deese-Roediger-McDermott (DRM) procedure and the Misinformation Effect Paradigm tasks were related to each other using distressing and neutral stimuli. Participants completed the DRM (with negative and neutral word lists) and viewed a distressing or neutral film. Misinformation for the film was introduced and memory was assessed. Film accuracy and misinformation susceptibility were found to be greater for those who viewed the distressing film relative to the neutral film. Accuracy responses on both tasks were related, however, susceptibility to the DRM illusion and Misinformation Effect were not. The misinformation findings support the Paradoxical Negative Emotion (PNE) hypothesis that negative stimuli will lead to remembering more accurate details but also greater likelihood of memory distortion. However, the PNE hypothesis was not supported for the DRM results. The findings also suggest that the DRM and Misinformation tasks are not equivalent and may have differences in underlying mechanisms. Future research should focus on more ecologically valid methods of assessing false memory.

  10. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  11. False alerts in air traffic control conflict alerting system: is there a "cry wolf" effect?

    Science.gov (United States)

    Wickens, Christopher D; Rice, Stephen; Keller, David; Hutchins, Shaun; Hughes, Jamie; Clayton, Krisstal

    2009-08-01

    The aim is to establish the extent to which the high false-alarm rate of air traffic control midair conflict alerts is responsible for a "cry wolf' effect-where true alerts are not responded to and all alerts are delayed in their response. Some aircraft collisions have been partly attributed to the cry wolf effect, and in other domains (health care and systems monitoring), there is a causal connection between false-alarm rate and cry wolf behavior. We hypothesized that a corresponding relationship exists in air traffic control (ATC). Aircraft track and alert system behavior data surrounding 495 conflict alerts were analyzed to identify true and false alerts, trajectory type, and controller behavior. Forty-five percent of the alerts were false, ranging from 0.28 to 0.58. Although centers with more false alerts contributed to more nonresponses, there was no evidence that these were nonresponses to true alerts or that response times were delayed in those centers. Instead, controllers showed desirable anticipatory behavior by issuing trajectory changes prior to the alert. Those trajectory pairs whose conflicts were more difficult to visualize induced more reliance on, and less compliance with, the alerting system. The high false-alarm rate does not appear to induce cry wolf behavior in the context of en route ATC conflict alerts. There is no need to substantially modify conflict alert algorithms, but the conflict alert system may be modified to address difficult-to-visualize conflicts.

  12. An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening

    International Nuclear Information System (INIS)

    Nightingale, Julie M.; Borgen, Rita; Porter-Bennett, Lisa; Szczepura, Katy

    2015-01-01

    Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negative psychosocial consequences reported. Women are at increased relative risk of breast cancer therefore their attendance at subsequent screening is essential. Aims: To assess the impact of FP breast screening diagnosis and diagnostic work-up on re-attendance rates across four consecutive screening rounds at a typical breast screening centre. Method: Diagnostic interventions and screening re-attendance rates at one prior and two consecutive rounds were analysed for women receiving an FP diagnosis between 2004 and 2006. Results: 397 women (5.57%) were referred for further assessment, including 228 (57.43%) false positives. 34 eligible women failed to re-attend routine screening (+3 years), with 17 failing to re-attend subsequently (+6 years). 70.6% (24/34) of non-attenders had attended at least two screening rounds prior to FP assessment. 75% of FP women had an imaging-only assessment with 17.5% (30/171) failing to re-attend, and 25% received a biopsy, with 7% (4/57) failing to re-attend subsequently. Conclusion: This study is unique as it follows FP women through four consecutive screening rounds. FP non-attendance rates were considerably lower compared to the general screening population, with diagnostic work-up having limited influence. FP non-attendance may appear insignificant in comparison to total screened population, but these women are at greater risk of subsequent cancer so should be actively encouraged to re-engage with the screening programme

  13. Detectability and detection rate of acute cerebral hemisphere infarcts on CT and diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Urbach, H.; Flacke, S.; Keller, E.; Textor, J.; Berlis, A.; Reul, J.; Schild, H.H.; Hartmann, A.; Solymosi, L.

    2000-01-01

    Our purpose was to compare the detectability and detection rate of acute ischaemic cerebral hemisphere infarcts on CT and diffusion-weighted MRI (DWI). We investigated 32 consecutive patients with acute hemisphere stroke with unenhanced CT and DWI within 6 h of stroke onset. The interval between CT and DWI ranged from 15 to 180 min (mean 60 min). Infarct detectability on CT and DWI was determined by comparing the initial CT, DWI and later reference images in a consensus reading of five independent examiners. The ''true'' detection rate was assessed by analysing all single readings. Two patients had intracerebral haematomas on DWI and CT and were excluded. There were 27 patients with ischaemic infarcts; all were visible on DWI and proven by follow-up. DWI was negative in three patients without a final diagnosis of infarct (100 % sensitivity, 100 % specificity, χ 2 = 30, P 2 = 1.48, P = 0.224). With regard to the single readings (30 examinations x 5 examiners = 150 readings), 63 CT readings were true positive and 72 false negative (sensitivity 47 %, specificity 86 %, χ 2 = 2.88, P = 0.089). Of the DWI readings 128 were true positive and 7 false negative (sensitivity 95 %, specificity 87 %, χ 2 = 70.67, P < 0.0001). Interobserver agreement was substantial for CT (χ= 0.72, 95 % confidence interval, 0.6-0.84) and DWI (χ= 0.82, 95 % confidence interval, 0.46-1). Taken together, detectability and detection rate of acute (< 6 h) hemisphere infarcts are significantly higher with DWI than with CT. (orig.)

  14. Sample size for comparing negative binomial rates in noninferiority and equivalence trials with unequal follow-up times.

    Science.gov (United States)

    Tang, Yongqiang

    2017-05-25

    We derive the sample size formulae for comparing two negative binomial rates based on both the relative and absolute rate difference metrics in noninferiority and equivalence trials with unequal follow-up times, and establish an approximate relationship between the sample sizes required for the treatment comparison based on the two treatment effect metrics. The proposed method allows the dispersion parameter to vary by treatment groups. The accuracy of these methods is assessed by simulations. It is demonstrated that ignoring the between-subject variation in the follow-up time by setting the follow-up time for all individuals to be the mean follow-up time may greatly underestimate the required size, resulting in underpowered studies. Methods are provided for back-calculating the dispersion parameter based on the published summary results.

  15. Atomic negative ions

    International Nuclear Information System (INIS)

    Brage, T.

    1991-01-01

    We review some of the recent progress in the studies of alkaline-earth, negative ions. Computations of autodetachment rates, electron affinities and transition wavelengths are discussed and some new and improved results are given

  16. False positive paediatric labelled white blood cell study

    International Nuclear Information System (INIS)

    Beveridge, N.; Bennett, E.; Thomas, P.

    2002-01-01

    Full text: An eight-month-old female presented for a technetium labelled white blood cell study (LWBC) to exclude an intra-abdominal abscess. Born premature, the child had surgery to repair a perforated bowel and had repeated presentations with diarrhoea, fevers, a tender right upper quadrant and a raised leucocyte count. Multiple imaging modalities failed to demonstrate recurrent bowel perforation, ischaemia or an intra-abdominal mass. A LWBC study was performed with whole body imaging at 1 and 5 hours post re-injection of the radiolabelled blood. No abnormal uptake was visualised in the abdomen but abnormal white cell accumulation was noted in the right hind foot and the length of the right lower leg. This activity appeared to lie along the course of the right tibia. Plain X-ray demonstrated no evidence of tibial osteomyelitis. Concern that the LWBC may be falsely negative in a patient on antibiotics, a gallium scan was immediately performed to re-examine the abdomen. The whole body gallium images demonstrated normal physiological uptake in the abdomen and no evidence of infection in the right leg. The patient had no clinical features to support right leg pathology. The abnormal LWBC localisation in the right lower leg/foot was therefore falsely positive. The most likely explanation is increased activation of the autologous LWBC by 'rough' handling during difficult venesection and re-injection through small veins and needles/cannulas. The slow flow through the veins draining the foot injection site would contribute to margination in these vessel walls. This is a potential cause for false positive LWBC studies- with significant implications for patient care. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  18. Non-linear Heart Rate Variability as a Discriminator of Internalizing Psychopathology and Negative Affect in Children With Internalizing Problems and Healthy Controls

    Directory of Open Access Journals (Sweden)

    Charlotte Fiskum

    2018-05-01

    Full Text Available Background: Internalizing psychopathology and dysregulated negative affect are characterized by dysregulation in the autonomic nervous system and reduced heart rate variability (HRV due to increases in sympathetic activity alongside reduced vagal tone. The neurovisceral system is however, a complex nonlinear system, and nonlinear indices related to psychopathology are so far less studied in children. Essential nonlinear properties of a system can be found in two main domains: the informational domain and the invariant domain. sample entropy (SampEn is a much-used method from the informational domain, while detrended fluctuation analysis (DFA represents a widely-used method from the invariant domain. To see if nonlinear HRV can provide information beyond linear indices of autonomic activation, this study investigated SampEn and DFA as discriminators of internalizing psychopathology and negative affect alongside measures of vagally-mediated HRV and sympathetic activation.Material and Methods: Thirty-Two children with internalizing difficulties and 25 healthy controls (aged 9–13 were assessed with the Child Behavior Checklist and the Early Adolescent Temperament Questionnaire, Revised, giving an estimate of internalizing psychopathology, negative affect and effortful control, a protective factor against psychopathology. Five minute electrocardiogram and impedance cardiography recordings were collected during a resting baseline, giving estimates of SampEn, DFA short-term scaling exponent α1, root mean square of successive differences (RMSSD, and pre-ejection period (PEP. Between-group differences and correlations were assessed with parametric and non-parametric tests, and the relationships between cardiac variables, psychopathology and negative affect were assessed using generalized linear modeling.Results: SampEn and DFA were not significantly different between the groups. SampEn was weakly negatively related to heart rate (HR in the controls

  19. False discovery rate control incorporating phylogenetic tree increases detection power in microbiome-wide multiple testing.

    Science.gov (United States)

    Xiao, Jian; Cao, Hongyuan; Chen, Jun

    2017-09-15

    Next generation sequencing technologies have enabled the study of the human microbiome through direct sequencing of microbial DNA, resulting in an enormous amount of microbiome sequencing data. One unique characteristic of microbiome data is the phylogenetic tree that relates all the bacterial species. Closely related bacterial species have a tendency to exhibit a similar relationship with the environment or disease. Thus, incorporating the phylogenetic tree information can potentially improve the detection power for microbiome-wide association studies, where hundreds or thousands of tests are conducted simultaneously to identify bacterial species associated with a phenotype of interest. Despite much progress in multiple testing procedures such as false discovery rate (FDR) control, methods that take into account the phylogenetic tree are largely limited. We propose a new FDR control procedure that incorporates the prior structure information and apply it to microbiome data. The proposed procedure is based on a hierarchical model, where a structure-based prior distribution is designed to utilize the phylogenetic tree. By borrowing information from neighboring bacterial species, we are able to improve the statistical power of detecting associated bacterial species while controlling the FDR at desired levels. When the phylogenetic tree is mis-specified or non-informative, our procedure achieves a similar power as traditional procedures that do not take into account the tree structure. We demonstrate the performance of our method through extensive simulations and real microbiome datasets. We identified far more alcohol-drinking associated bacterial species than traditional methods. R package StructFDR is available from CRAN. chen.jun2@mayo.edu. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  20. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  1. Information Filtering Based on Users' Negative Opinions

    Science.gov (United States)

    Guo, Qiang; Li, Yang; Liu, Jian-Guo

    2013-05-01

    The process of heat conduction (HC) has recently found application in the information filtering [Zhang et al., Phys. Rev. Lett.99, 154301 (2007)], which is of high diversity but low accuracy. The classical HC model predicts users' potential interested objects based on their interesting objects regardless to the negative opinions. In terms of the users' rating scores, we present an improved user-based HC (UHC) information model by taking into account users' positive and negative opinions. Firstly, the objects rated by users are divided into positive and negative categories, then the predicted interesting and dislike object lists are generated by the UHC model. Finally, the recommendation lists are constructed by filtering out the dislike objects from the interesting lists. By implementing the new model based on nine similarity measures, the experimental results for MovieLens and Netflix datasets show that the new model considering negative opinions could greatly enhance the accuracy, measured by the average ranking score, from 0.049 to 0.036 for Netflix and from 0.1025 to 0.0570 for Movielens dataset, reduced by 26.53% and 44.39%, respectively. Since users prefer to give positive ratings rather than negative ones, the negative opinions contain much more information than the positive ones, the negative opinions, therefore, are very important for understanding users' online collective behaviors and improving the performance of HC model.

  2. Low-Rate DDoS Attack Detection Using Expectation of Packet Size

    Directory of Open Access Journals (Sweden)

    Lu Zhou

    2017-01-01

    Full Text Available Low-rate Distributed Denial-of-Service (low-rate DDoS attacks are a new challenge to cyberspace, as the attackers send a large amount of attack packets similar to normal traffic, to throttle legitimate flows. In this paper, we propose a measurement—expectation of packet size—that is based on the distribution difference of the packet size to distinguish two typical low-rate DDoS attacks, the constant attack and the pulsing attack, from legitimate traffic. The experimental results, obtained using a series of real datasets with different times and different tolerance factors, are presented to demonstrate the effectiveness of the proposed measurement. In addition, extensive experiments are performed to show that the proposed measurement can detect the low-rate DDoS attacks not only in the short and long terms but also for low packet rates and high packet rates. Furthermore, the false-negative rates and the adjudication distance can be adjusted based on the detection sensitivity requirements.

  3. False memory production :effects of self-consistent false information and motivated cognition

    OpenAIRE

    Brown, Martha

    1996-01-01

    Remembrance of one's personal past and the development of false memories have recently received intense public scrutiny. Based upon self-schema (Markus, 1977) and selfverification (Swann, 1987) theories, two studies were conducted to investigate the hypothesis that a self-schema guides cognitive processing of self-relevant information and thereby influences the construction of a memory that includes false information, particularly more so if this information is self-schema consistent than ...

  4. Lay theories about social class buffer lower-class individuals against poor self-rated health and negative affect.

    Science.gov (United States)

    Tan, Jacinth J X; Kraus, Michael W

    2015-03-01

    The economic conditions of one's life can profoundly and systematically influence health outcomes over the life course. Our present research demonstrates that rejecting the notion that social class categories are biologically determined-a nonessentialist belief-buffers lower-class individuals from poor self-rated health and negative affect, whereas conceiving of social class categories as rooted in biology-an essentialist belief-does not. In Study 1, lower-class individuals self-reported poorer health than upper-class individuals when they endorsed essentialist beliefs but showed no such difference when they rejected such beliefs. Exposure to essentialist theories of social class also led lower-class individuals to report greater feelings of negative self-conscious emotions (Studies 2 and 3), and perceive poorer health (Study 3) than upper-class individuals, whereas exposure to nonessentialist theories did not lead to such differences. Discussion considers how lay theories of social class potentially shape long-term trajectories of health and affect of lower-class individuals. © 2015 by the Society for Personality and Social Psychology, Inc.

  5. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  6. False memory in aging: effects of emotional valence on word recognition accuracy.

    Science.gov (United States)

    Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne

    2008-06-01

    Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.

  7. 19 CFR 111.32 - False information.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false False information. 111.32 Section 111.32 Customs... CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.32 False information. A broker must... procure the giving of, any false or misleading information or testimony in any matter pending before the...

  8. Patient characteristics associated with false arrhythmia alarms in intensive care

    Directory of Open Access Journals (Sweden)

    Harris PR

    2017-04-01

    Full Text Available Patricia R Harris,1,2 Jessica K Zègre-Hemsey,3,4 Daniel Schindler,5 Yong Bai,6 Michele M Pelter,2,7 Xiao Hu2,8 1Department of Nursing, School of Health and Natural Sciences, Dominican University of California, San Rafael, 2Department of Physiological Nursing, School of Nursing, University of California, San Francisco, CA, 3School of Nursing, 4Department of Emergency Medicine, School of Medicine, University of North Carolina at Chapel Hill, NC, 5Intensive Care Unit, The Neuroscience Center, Sutter Eden Medical Center, Castro Valley, 6Hu Research Laboratory, Department of Physiological Nursing, School of Nursing, University of California, San Francisco, 7ECG Monitoring Research Lab, Department of Physiological Nursing, School of Nursing, 8Physiological Nursing and Neurological Surgery, Affiliate Faculty of Institute for Computational Health Sciences Core Faculty UCB/UCSF Joint Bio-Engineering Graduate Program, University of California, San Francisco, CA, USA Introduction: A high rate of false arrhythmia alarms in the intensive care unit (ICU leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective: The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods: This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and

  9. Evaluation of Patients with an Apparent False Positive Stool DNA Test: The Role of Repeat Stool DNA Testing.

    Science.gov (United States)

    Cooper, Gregory S; Markowitz, Sanford D; Chen, Zhengyi; Tuck, Missy; Willis, Joseph E; Berger, Barry M; Brenner, Dean E; Li, Li

    2018-03-07

    There is uncertainty as to the appropriate follow-up of patients who test positive on multimarker stool DNA (sDNA) testing and have a colonoscopy without neoplasia. To determine the prevalence of missed colonic or occult upper gastrointestinal neoplasia in patients with an apparent false positive sDNA. We prospectively identified 30 patients who tested positive with a commercially available sDNA followed by colonoscopy without neoplastic lesions. Patients were invited to undergo repeat sDNA at 11-29 months after the initial test followed by repeat colonoscopy and upper endoscopy. We determined the presence of neoplastic lesions on repeat evaluation stratified by results of repeat sDNA. Twelve patients were restudied. Seven patients had a negative second sDNA test and a normal second colonoscopy and upper endoscopy. In contrast, 5 of 12 subjects had a persistently positive second sDNA test, and 3 had positive findings, including a 3-cm sessile transverse colon adenoma with high-grade dysplasia, a 2-cm right colon sessile serrated adenoma with dysplasia, and a nonadvanced colon adenoma (p = 0.045). These corresponded to a positive predictive value of 0.60 (95% CI 0.17-1.00) and a negative predictive value of 1.00 (95% CI 1.00-1.00) for the second sDNA test. In addition, the medical records of all 30 subjects with apparent false positive testing were reviewed and no documented cases of malignant tumors were recorded. Repeat positive sDNA testing may identify a subset of patients with missed or occult colorectal neoplasia after negative colonoscopy for an initially positive sDNA. High-quality colonoscopy with careful attention to the right colon in patients with positive sDNA is critically important and may avoid false negative colonoscopy.

  10. Complementarity in false memory illusions.

    Science.gov (United States)

    Brainerd, C J; Reyna, V F

    2018-03-01

    For some years, the DRM illusion has been the most widely studied form of false memory. The consensus theoretical interpretation is that the illusion is a reality reversal, in which certain new words (critical distractors) are remembered as though they are old list words rather than as what they are-new words that are similar to old ones. This reality-reversal interpretation is supported by compelling lines of evidence, but prior experiments are limited by the fact that their memory tests only asked whether test items were old. We removed that limitation by also asking whether test items were new-similar. This more comprehensive methodology revealed that list words and critical distractors are remembered quite differently. Memory for list words is compensatory: They are remembered as old at high rates and remembered as new-similar at very low rates. In contrast, memory for critical distractors is complementary: They are remembered as both old and new-similar at high rates, which means that the DRM procedure induces a complementarity illusion rather than a reality reversal. The conjoint recognition model explains complementarity as a function of three retrieval processes (semantic familiarity, target recollection, and context recollection), and it predicts that complementarity can be driven up or down by varying the mix of those processes. Our experiments generated data on that prediction and introduced a convenient statistic, the complementarity ratio, which measures (a) the level of complementarity in memory performance and (b) whether its direction is reality-consistent or reality-reversed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  11. Evaluation of non-genomic, clinical risk and survival results in endocrine-sensitive, HER-2 negative, node negative breast cancer.

    Science.gov (United States)

    Baena Cañada, José M; Gámez Casado, Salvador; Rodríguez Pérez, Lourdes; Quílez Cutillas, Alicia; Cortés Carmona, Cristina; Rosado Varela, Petra; Estalella Mendoza, Sara; Ramírez Daffós, Patricia; Benítez Rodríguez, Encarnación

    2018-02-28

    In endocrine-sensitive, HER-2 negative, node negative breast cancer, the presence of a low genomic risk allows treatment with adjuvant endocrine therapy alone, obtaining excellent survival rates. The justification for this study is to show that excellent survival rates are also obtained by treating with adjuvant hormone therapy alone, based on clinical risk assessment. A descriptive, observational and retrospective study was performed between 2006 and 2016 with endocrine-sensitive, HER-2 negative, node negative breast cancer, greater than 1cm or between 0.6 and 1cm with unfavourable features. Retrospective review of health records. Mortality data of the National Registry of Deaths. A total of 203 patients were evaluable for survival. One hundred and twenty-three (60.50%) were treated with adjuvant endocrine therapy alone, 77 (37.90%) with chemotherapy and endocrine therapy, one (0.50%) with chemotherapy alone and 2 (1%) were not treated. The overall survival rate at 5 years was 97% (95% confidence interval [CI] 94-100). Distant recurrence-free interval was 94% (95% CI 90-98). In the subgroup of patients treated with endocrine therapy alone, overall survival and distant recurrence-free interval rates at 5 years were 98% (95% CI 95-100) and 97% (95% CI 93-100), respectively. Patients with endocrine-sensitive, HER-2-negative, node negative breast cancer treated with endocrine therapy alone according to their clinical risk have similar survival outcomes as those treated with endocrine therapy according to their genomic risk. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  12. Psychoactive drugs and false memory: comparison of dextroamphetamine and delta-9-tetrahydrocannabinol on false recognition

    Science.gov (United States)

    Ballard, Michael E.; Gallo, David A.; de Wit, Harriet

    2014-01-01

    Rationale Several psychoactive drugs are known to influence episodic memory. However, these drugs’ effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Objectives Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ9-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger–McDermott (DRM) illusion. Methods Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. Results As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs’ effects on true memory were positively correlated with their effects on false memory. Conclusions Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories. PMID:21647577

  13. Psychoactive drugs and false memory: comparison of dextroamphetamine and δ-9-tetrahydrocannabinol on false recognition.

    Science.gov (United States)

    Ballard, Michael E; Gallo, David A; de Wit, Harriet

    2012-01-01

    Several psychoactive drugs are known to influence episodic memory. However, these drugs' effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ(9)-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger-McDermott (DRM) illusion. Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs' effects on true memory were positively correlated with their effects on false memory. Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories.

  14. Positive and Negative Peer Influence in Residential Care.

    Science.gov (United States)

    Huefner, Jonathan C; Smith, Gail L; Stevens, Amy L

    2017-10-13

    The potential for negative peer influence has been well established in research, and there is a growing interest in how positive peer influence also impacts youth. No research, however, has concurrently examined positive and negative peer influence in the context of residential care. Clinical records for 886 residential care youth were used in a Hierarchical Linear Model analysis to examine the impact of negative and positive peer influence on naturally occurring patterns of serious problem behavior over time. Negative peer influence, where the majority of youth in a home manifested above the average number of serious behavior problems, occurred 13.7% of the time. Positive peer influence, where the majority of youth manifested no serious problem behaviors for the month, occurred 47.7% of the time. Overall, youth problem behavior improved over time. There were significantly lower rates of serious problem behavior in target youth during positive peer influence months. Conversely, there were significantly higher rates of serious problem behaviors in target youth during negative peer influence months. Negative peer influence had a relatively greater impact on target peers' serious behavior problems than did positive peer influence. Caregiver experience significantly reduced the impact of negative peer influence, but did not significantly augment positive peer influence. Months where negative peer influence was combined with inexperienced caregivers produced the highest rates of serious problem behavior. Our results support the view that residential programs for troubled youth need to create circumstances that promote positive and control for negative peer influence.

  15. 29 CFR 778.112 - Day rates and job rates.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Day rates and job rates. 778.112 Section 778.112 Labor... Requirements Principles for Computing Overtime Pay Based on the âregular Rateâ § 778.112 Day rates and job rates. If the employee is paid a flat sum for a day's work or for doing a particular job, without regard...

  16. [Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].

    Science.gov (United States)

    Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei

    2017-08-01

    To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.

  17. Interference Helps to Equalize the Read Range and Reduce False Positives of Passive RFID Tags

    DEFF Research Database (Denmark)

    Krigslund, Rasmus; Popovski, Petar; Pedersen, Gert Frølund

    2012-01-01

    In various applications of RFID systems a reader should reliably get the ID of the tags that are within a bounded proximity region, termed the interrogation zone. This gives rise to two types of errors 1) False Negative Detections (FNDs), when tags within the intended interrogation zone cannot...... interference enables design of well-defined interrogation zones for passive RFID systems....

  18. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  19. 47 CFR 64.1801 - Geographic rate averaging and rate integration.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Geographic rate averaging and rate integration. 64.1801 Section 64.1801 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) MISCELLANEOUS RULES RELATING TO COMMON CARRIERS Geographic Rate Averaging and...

  20. Effects of false yam tuber meals and charcoal on broiler chicken ...

    African Journals Online (AJOL)

    The authors investigated the effects of replacing a portion of a commercial broiler feed with false yam tuber meals on broiler growth performance, feed conversion rate (FCR) and blood parameters. Furthermore, wood charcoal was added at various levels to the meals to explore their potential to attenuate toxic effects.

  1. Quantitative real-time PCR as a sensitive protein-protein interaction quantification method and a partial solution for non-accessible autoactivator and false-negative molecule analysis in the yeast two-hybrid system.

    Science.gov (United States)

    Maier, Richard H; Maier, Christina J; Hintner, Helmut; Bauer, Johann W; Onder, Kamil

    2012-12-01

    Many functional proteomic experiments make use of high-throughput technologies such as mass spectrometry combined with two-dimensional polyacrylamide gel electrophoresis and the yeast two-hybrid (Y2H) system. Currently there are even automated versions of the Y2H system available that can be used for proteome-wide research. The Y2H system has the capacity to deliver a profusion of Y2H positive colonies from a single library screen. However, subsequent analysis of these numerous primary candidates with complementary methods can be overwhelming. Therefore, a method to select the most promising candidates with strong interaction properties might be useful to reduce the number of candidates requiring further analysis. The method described here offers a new way of quantifying and rating the performance of positive Y2H candidates. The novelty lies in the detection and measurement of mRNA expression instead of proteins or conventional Y2H genetic reporters. This method correlates well with the direct genetic reporter readouts usually used in the Y2H system, and has greater sensitivity for detecting and quantifying protein-protein interactions (PPIs) than the conventional Y2H system, as demonstrated by detection of the Y2H false-negative PPI of RXR/PPARG. Approximately 20% of all proteins are not suitable for the Y2H system, the so-called autoactivators. A further advantage of this method is the possibility to evaluate molecules that usually cannot be analyzed in the Y2H system, exemplified by a VDR-LXXLL motif peptide interaction. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Easy and Informative: Using Confidence-Weighted True-False Items for Knowledge Tests in Psychology Courses

    Science.gov (United States)

    Dutke, Stephan; Barenberg, Jonathan

    2015-01-01

    We introduce a specific type of item for knowledge tests, confidence-weighted true-false (CTF) items, and review experiences of its application in psychology courses. A CTF item is a statement about the learning content to which students respond whether the statement is true or false, and they rate their confidence level. Previous studies using…

  3. Dissociative effects of true and false recall as a function of different encoding strategies.

    Science.gov (United States)

    Goodwin, Kerri A

    2007-01-01

    Goodwin, Meissner, and Ericsson (2001) proposed a path model in which elaborative encoding predicted the likelihood of verbalisation of critical, nonpresented words at encoding, which in turn predicted the likelihood of false recall. The present study tested this model of false recall experimentally with a manipulation of encoding strategy and the implementation of the process-tracing technique of protocol analysis. Findings indicated that elaborative encoding led to more verbalisations of critical items during encoding than rote rehearsal of list items, but false recall rates were reduced under elaboration conditions (Experiment 2). Interestingly, false recall was more likely to occur when items were verbalised during encoding than not verbalised (Experiment 1), and participants tended to reinstate their encoding strategies during recall, particularly after elaborative encoding (Experiment 1). Theoretical implications for the interplay of encoding and retrieval processes of false recall are discussed.

  4. Next-generation negative symptom assessment for clinical trials: validation of the Brief Negative Symptom Scale.

    Science.gov (United States)

    Strauss, Gregory P; Keller, William R; Buchanan, Robert W; Gold, James M; Fischer, Bernard A; McMahon, Robert P; Catalano, Lauren T; Culbreth, Adam J; Carpenter, William T; Kirkpatrick, Brian

    2012-12-01

    The current study examined the psychometric properties of the Brief Negative Symptom Scale (BNSS), a next-generation rating instrument developed in response to the NIMH sponsored consensus development conference on negative symptoms. Participants included 100 individuals with a DSM-IV diagnosis of schizophrenia or schizoaffective disorder who completed a clinical interview designed to assess negative, positive, disorganized, and general psychiatric symptoms, as well as functional outcome. A battery of anhedonia questionnaires and neuropsychological tests were also administered. Results indicated that the BNSS has excellent internal consistency and temporal stability, as well as good convergent and discriminant validity in its relationships with other symptom rating scales, functional outcome, self-reported anhedonia, and neuropsychological test scores. Given its brevity (13-items, 15-minute interview) and good psychometric characteristics, the BNSS can be considered a promising new instrument for use in clinical trials. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Can Implicit Associations Distinguish True and False Eyewitness Memory? Development and Preliminary Testing of the IATe.

    Science.gov (United States)

    Helm, Rebecca K; Ceci, Stephen J; Burd, Kayla A

    2016-11-01

    Eyewitness identification has been shown to be fallible and prone to false memory. In this study we develop and test a new method to probe the mechanisms involved in the formation of false memories in this area, and determine whether a particular memory is likely to be true or false. We created a seven-step procedure based on the Implicit Association Test to gauge implicit biases in eyewitness identification (the IATe). We show that identification errors may result from unconscious bias caused by implicit associations evoked by a given face. We also show that implicit associations between negative attributions such as guilt and eyewitnesses' final pick from a line-up can help to distinguish between true and false memory (especially where the witness has been subject to the suggestive nature of a prior blank line-up). Specifically, the more a witness implicitly associates an individual face with a particular crime, the more likely it is that a memory they have for that person committing the crime is false. These findings are consistent with existing findings in the memory and neuroscience literature showing that false memories can be caused by implicit associations that are outside conscious awareness. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Abnormal daily situations and negative affects in Peru

    Directory of Open Access Journals (Sweden)

    Ramón León

    2002-12-01

    Full Text Available Four hundred seventy nine Peruvian students (188 mal e and 291 female rated the frequency of negative social emotions in themselves, in their neighborhood, and in the Peruvian society; and the frequency of anomalous daily situations. Verbal aggressions and gossiping obtained the highest averages in the evaluations of affects in the neighborhood, but solidarity was rated as high than the negative affects. In the Peruvian society, envy and physical aggression were rated asthe highest, and the positive affects obtained the smallest averages. To be a victim of an assault,to be cheated, and to be insulted obtained the highest averages in anomalous situations. Resentment and anger were the most salient negative affects.

  7. Multiple splicing defects in an intronic false exon.

    Science.gov (United States)

    Sun, H; Chasin, L A

    2000-09-01

    Splice site consensus sequences alone are insufficient to dictate the recognition of real constitutive splice sites within the typically large transcripts of higher eukaryotes, and large numbers of pseudoexons flanked by pseudosplice sites with good matches to the consensus sequences can be easily designated. In an attempt to identify elements that prevent pseudoexon splicing, we have systematically altered known splicing signals, as well as immediately adjacent flanking sequences, of an arbitrarily chosen pseudoexon from intron 1 of the human hprt gene. The substitution of a 5' splice site that perfectly matches the 5' consensus combined with mutation to match the CAG/G sequence of the 3' consensus failed to get this model pseudoexon included as the central exon in a dhfr minigene context. Provision of a real 3' splice site and a consensus 5' splice site and removal of an upstream inhibitory sequence were necessary and sufficient to confer splicing on the pseudoexon. This activated context also supported the splicing of a second pseudoexon sequence containing no apparent enhancer. Thus, both the 5' splice site sequence and the polypyrimidine tract of the pseudoexon are defective despite their good agreement with the consensus. On the other hand, the pseudoexon body did not exert a negative influence on splicing. The introduction into the pseudoexon of a sequence selected for binding to ASF/SF2 or its replacement with beta-globin exon 2 only partially reversed the effect of the upstream negative element and the defective polypyrimidine tract. These results support the idea that exon-bridging enhancers are not a prerequisite for constitutive exon definition and suggest that intrinsically defective splice sites and negative elements play important roles in distinguishing the real splicing signal from the vast number of false splicing signals.

  8. Processes Underlying Developmental Reversals in False-Memory Formation: Comment on Brainerd, Reyna, and Ceci (2008)

    Science.gov (United States)

    Ghetti, Simona

    2008-01-01

    C. J. Brainerd, V. F. Reyna, and S. J. Ceci (2008) reviewed compelling evidence of developmental reversals in false-memory formation (i.e., younger children exhibit lower false-memory rates than do older children and adults) and proposed that this phenomenon depends on the development of gist processing (i.e., the ability to identify and process…

  9. False alarms and incorrect rejections in an information security center: correlation with the frequency of incidents.

    Science.gov (United States)

    Bruno, Thiers; Abrahão, Julia

    2012-01-01

    This study examines the actions taken by operators aimed at preventing and combating information security incidents at a banking organization. The work utilizes the theoretical framework of ergonomics and cognitive psychology. The method is workplace ergonomic analysis. Its focus is directed towards examining the cognitive dimension of the work environment with special attention to the occurrence of correlations between variability in incident frequency and the results of sign detection actions. It categorizes 45,142 operator decisions according to the theory of signal detection (Sternberg, 2000). It analyzes the correlation between incident proportions (indirectly associated with the cognitive efforts demanded from the operator) and operator decisions. The study demonstrated the existence of a positive correlation between incident proportions and false positive decisions (false alarms). However, this correlation could not be observed in relation to decisions of the false-negative type (incorrect rejection).

  10. Use of the local false discovery rate for identification of metabolic biomarkers in rat urine following Genkwa Flos-induced hepatotoxicity.

    Directory of Open Access Journals (Sweden)

    Zuojing Li

    Full Text Available Metabolomics is concerned with characterizing the large number of metabolites present in a biological system using nuclear magnetic resonance (NMR and HPLC/MS (high-performance liquid chromatography with mass spectrometry. Multivariate analysis is one of the most important tools for metabolic biomarker identification in metabolomic studies. However, analyzing the large-scale data sets acquired during metabolic fingerprinting is a major challenge. As a posterior probability that the features of interest are not affected, the local false discovery rate (LFDR is a good interpretable measure. However, it is rarely used to when interrogating metabolic data to identify biomarkers. In this study, we employed the LFDR method to analyze HPLC/MS data acquired from a metabolomic study of metabolic changes in rat urine during hepatotoxicity induced by Genkwa flos (GF treatment. The LFDR approach was successfully used to identify important rat urine metabolites altered by GF-stimulated hepatotoxicity. Compared with principle component analysis (PCA, LFDR is an interpretable measure and discovers more important metabolites in an HPLC/MS-based metabolomic study.

  11. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    Science.gov (United States)

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  12. The probability of false positives in zero-dimensional analyses of one-dimensional kinematic, force and EMG trajectories.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2016-06-14

    A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Negative correlation between rates of molecular evolution and flowering cycles in temperate woody bamboos revealed by plastid phylogenomics.

    Science.gov (United States)

    Ma, Peng-Fei; Vorontsova, Maria S; Nanjarisoa, Olinirina Prisca; Razanatsoa, Jacqueline; Guo, Zhen-Hua; Haevermans, Thomas; Li, De-Zhu

    2017-12-21

    Heterogeneous rates of molecular evolution are universal across the tree of life, posing challenges for phylogenetic inference. The temperate woody bamboos (tribe Arundinarieae, Poaceae) are noted for their extremely slow molecular evolutionary rates, supposedly caused by their mysterious monocarpic reproduction. However, the correlation between substitution rates and flowering cycles has not been formally tested. Here we present 15 newly sequenced plastid genomes of temperate woody bamboos, including the first genomes ever sequenced from Madagascar representatives. A data matrix of 46 plastid genomes representing all 12 lineages of Arundinarieae was assembled for phylogenetic and molecular evolutionary analyses. We conducted phylogenetic analyses using different sequences (e.g., coding and noncoding) combined with different data partitioning schemes, revealing conflicting relationships involving internodes among several lineages. A great difference in branch lengths were observed among the major lineages, and topological inconsistency could be attributed to long-branch attraction (LBA). Using clock model-fitting by maximum likelihood and Bayesian approaches, we furthermore demonstrated extensive rate variation among these major lineages. Rate accelerations mainly occurred for the isolated lineages with limited species diversification, totaling 11 rate shifts during the tribe's evolution. Using linear regression analysis, we found a negative correlation between rates of molecular evolution and flowering cycles for Arundinarieae, notwithstanding that the correlation maybe insignificant when taking the phylogenetic structure into account. Using the temperate woody bamboos as an example, we found further evidence that rate heterogeneity is universal in plants, suggesting that this will pose a challenge for phylogenetic reconstruction of bamboos. The bamboos with longer flowering cycles tend to evolve more slowly than those with shorter flowering cycles, in accordance

  14. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    Science.gov (United States)

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  15. Improved Detection of Common Variants Associated with Schizophrenia and Bipolar Disorder Using Pleiotropy-Informed Conditional False Discovery Rate

    Science.gov (United States)

    Andreassen, Ole A.; Thompson, Wesley K.; Schork, Andrew J.; Ripke, Stephan; Mattingsdal, Morten; Kelsoe, John R.; Kendler, Kenneth S.; O'Donovan, Michael C.; Rujescu, Dan; Werge, Thomas; Sklar, Pamela; Roddey, J. Cooper; Chen, Chi-Hua; McEvoy, Linda; Desikan, Rahul S.; Djurovic, Srdjan; Dale, Anders M.

    2013-01-01

    Several lines of evidence suggest that genome-wide association studies (GWAS) have the potential to explain more of the “missing heritability” of common complex phenotypes. However, reliable methods to identify a larger proportion of single nucleotide polymorphisms (SNPs) that impact disease risk are currently lacking. Here, we use a genetic pleiotropy-informed conditional false discovery rate (FDR) method on GWAS summary statistics data to identify new loci associated with schizophrenia (SCZ) and bipolar disorders (BD), two highly heritable disorders with significant missing heritability. Epidemiological and clinical evidence suggest similar disease characteristics and overlapping genes between SCZ and BD. Here, we computed conditional Q–Q curves of data from the Psychiatric Genome Consortium (SCZ; n = 9,379 cases and n = 7,736 controls; BD: n = 6,990 cases and n = 4,820 controls) to show enrichment of SNPs associated with SCZ as a function of association with BD and vice versa with a corresponding reduction in FDR. Applying the conditional FDR method, we identified 58 loci associated with SCZ and 35 loci associated with BD below the conditional FDR level of 0.05. Of these, 14 loci were associated with both SCZ and BD (conjunction FDR). Together, these findings show the feasibility of genetic pleiotropy-informed methods to improve gene discovery in SCZ and BD and indicate overlapping genetic mechanisms between these two disorders. PMID:23637625

  16. Survival and local control rates of triple-negative breast cancer patients treated with boost-IOERT during breast-conserving surgery

    Energy Technology Data Exchange (ETDEWEB)

    Fastner, Gerd; Zehentmayr, Franz; Kopp, Peter; Fussl, Christoph; Sedlmayer, Felix [Landeskrankenhaus, Paracelsus Medical University, Department of Radiotherapy and Radio-Oncology, Salzburg (Austria); Hauser-Kronberger, Cornelia [Landeskrankenhaus, Paracelsus Medical University, Department of Pathology, Salzburg (Austria); Moder, Angelika [Landeskrankenhaus, Paracelsus Medical University, Institute of Inborn Errors in Metabolism, Salzburg (Austria); Reitsamer, Roland; Fischer, Thorsten [Landeskrankenhaus, Paracelsus Medical University, Department of Special Gynecology, Salzburg (Austria); Landeskrankenhaus, Paracelsus Medical University, Department of Gynecology, Salzburg (Austria); Deutschmann, Heinrich [Landeskrankenhaus, Paracelsus Medical University, Department of Radiotherapy and Radio-Oncology, Salzburg (Austria); Paracelsus Medical University, Institute for Research and Development of Advanced Radiation Technologies (radART), Salzburg (Austria)

    2016-01-15

    The purpose of this work was to retrospectively evaluate survival and local control rates of triple-negative breast cancer subtypes classified as five marker negative (5NP) and core basal (CB), respectively, after breast-conserving surgery and intraoperative boost radiotherapy with electrons (IOERT) followed by whole breast irradiation. A total of 71 patients with triple-negative breast cancer were enrolled, who were treated with lumpectomy, axillary lymph node dissection, and IOERT with 9.6 Gy (median D{sub max}) followed by normofractionated whole breast irradiation to median total doses of 54 Gy. Chemotherapy was applied in a neoadjuvant (12 %), adjuvant (75 %), or combinational setting (7 %). After a median follow-up of 97 months (range 4-170 months), 5 in-breast recurrences were detected (7.0 %). For all patients, 8-year actuarial rates for local control, metastases-free survival, disease-specific survival, and overall survival amounted to 89, 75, 80, and 69 %, respectively. All local recurrences occurred in grade 3 (G3) tumors irrespective of their specific immunohistochemical phenotype; thus, the local control rate for grades 1/2 (G1/2) was 100 % for both 5NP and CB, while for G3 it was 88 % for 5NP and 90 % for CB (p = 0.65 and 0.82, respectively, n.s.). For disease-specific survival, only the difference of the best-prognosis group 5-NP/G3 vs. the worst-prognosis cohort CB/G1/2 was statistically significant: 90 % vs. 54 % (p = 0.03). Boost-IOERT provides acceptable long-term in-breast control in triple negative breast cancer. The best subgroup in terms of disease-specific survival was represented by 5NP in combination with tumor grading G3. (orig.) [German] Ziel der Studie war es, im Rahmen einer retrospektiven Analyse Ueberlebens- und Lokalkontrollraten bei triple-negativen Mammakarzinomen zu untersuchen. Die Tumoren waren in 5NP(5-Marker-negative)- und CB(core basal)-Subtypen klassifiziert und die Patientinnen hatten nach brusterhaltender Operation und

  17. Get the gist? The effects of processing depth on false recognition in short-term and long-term memory.

    Science.gov (United States)

    Flegal, Kristin E; Reuter-Lorenz, Patricia A

    2014-07-01

    Gist-based processing has been proposed to account for robust false memories in the converging-associates task. The deep-encoding processes known to enhance verbatim memory also strengthen gist memory and increase distortions of long-term memory (LTM). Recent research has demonstrated that compelling false memory illusions are relatively delay-invariant, also occurring under canonical short-term memory (STM) conditions. To investigate the contributions of gist to false memory at short and long delays, processing depth was manipulated as participants encoded lists of four semantically related words and were probed immediately, following a filled 3- to 4-s retention interval, or approximately 20 min later, in a surprise recognition test. In two experiments, the encoding manipulation dissociated STM and LTM on the frequency, but not the phenomenology, of false memory. Deep encoding at STM increases false recognition rates at LTM, but confidence ratings and remember/know judgments are similar across delays and do not differ as a function of processing depth. These results suggest that some shared and some unique processes underlie false memory illusions at short and long delays.

  18. Contrast-enhanced voiding urosonography phantom study: intravenous iodinated and gadolinium-based contrast agents may cause false-negative results in assessment of vesicoureteral reflux in children

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Sauer, Alexander; Gassenmaier, Tobias; Petritsch, Bernhard; Herz, Stefan; Blanke, Philipp; Bley, Thorsten A.; Wirth, Clemens; Derlin, Thorsten

    2015-01-01

    Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast. (orig.)

  19. Effect of gravity on false-vacuum decay rates for O(4)-symmetric bubble nucleation

    International Nuclear Information System (INIS)

    Samuel, D.A.; Hiscock, W.A.

    1991-01-01

    The self-gravity of quantum fields is often considered to be a negligible perturbation upon a background spacetime and not of much physical interest. Its importance is determined by the ratio of the mass of the field to the Planck mass, this ratio being very small for those fields that we are most familiar in dealing with. However, it is conceivable that either in the very early Universe or even today a false-vacuum decay could occur associated with a field of appreciable mass. The effect of self-gravity upon false-vacuum decay was initially studied within the ''thin-wall'' approximation by Coleman and De Luccia. Their analysis involved the approximate solution of the coupled Euclideanized field and Einstein equations with the assumption of O(4)-symmetric bubble nucleation. In this paper we consider the range of validity of the ''thin-wall'' approximation by comparing the Coleman--De Luccia results with exact numerical results for a quartic polynomial potential. We also extend the analysis into regimes for which the ''thin-wall'' approximation is inapplicable. In the case of an initially de Sitter space decaying into Minkowski space, we find a smooth transition between the Coleman--De Luccia mode of bubble formation and the Hawking-Moss transition, wherein the entire spacetime tunnels ''at once'' to the maximum of the potential. In the case of the decay of an initially Minkowski space to an anti--de Sitter space, we find that there is a ''forbidden region'' of vacuum potential parameters for which decay is not possible. At energies far below the Planck scale, the boundary of this region is accurately described by the thin-wall prediction obtained by Coleman and De Luccia. At energies near the Planck scale, however, the actual ''forbidden region'' is significantly smaller than predicted by the thin-wall approximation; thus, vacuum decays are possible which appear to be forbidden by thin-wall calculations

  20. Respiratory rate greater than 50 per minute as a clinical indicator of pneumonia in Filipino children with cough.

    Science.gov (United States)

    Lucero, M G; Tupasi, T E; Gomez, M L; Beltran, G L; Crisostomo, A U; Romano, V V; Rivera, L M

    1990-01-01

    The diagnosis and epidemiology of acute respiratory tract infection (ARI) in 199 children less than 5 years old were investigated in Manila. As part of this study, children who were treated at one of two outpatient clinics for cough of less than 3 weeks' duration were studied to test the validity of the use of a respiratory rate (RR) of greater than 50/minute for identifying ARI of a severity necessitating treatment with antibiotics. In the first population, in which 69% of the children had radiologically confirmed pneumonia, the sensitivity of a RR of greater than 50/minute was 54%, the specificity was 84%, the false-positive rate was 16%, and the false-negative rate was 46%. In the second population, in which 29% of the children had pneumonia, the sensitivity and positive predictive values were low. The validity of a RR of greater than 50/minute may vary in populations with different prevalences of ARI.

  1. Blind sequential lineup administration reduces both false identifications and confidence in those false identifications.

    Science.gov (United States)

    Charman, Steve D; Quiroz, Vanessa

    2016-10-01

    One of the most recommended procedures proposed by eyewitness experts is the use of double-blind lineups, in which the administrator does not know the identity of the suspect in the lineup. But despite the near universality of this recommendation, there is surprisingly little empirical research to support the claim that nonblind administration inflates false identifications. What little research has been conducted has shown conflicting findings with regard to the conditions under which nonblind administration affects false identifications, as well as its effects on witness confidence. The current study attempts to elucidate this effect. Student-participants (n = 312) were randomly assigned to play the role of either a lineup administrator (who were either told the identity of the suspect in the lineup or not) or a mock crime witness. Following unbiased instructions, administrators presented either a target-present or target-absent sequential lineup to the witness while being surreptitiously videorecorded. Nonblind administration significantly inflated false, but not correct, identifications, and significantly inflated witness confidence in those false identifications. Video recordings indicated that nonblind administrators were significantly more likely than blind administrators to smile (a) while the witness was viewing a photograph of the suspect, and (b) after a suspect identification. Results provide stronger support for the use of blind lineup administration by broadening the conditions under which nonblind administration is shown to inflate false identifications. Possible reconciliations for conflicting findings in the literature are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  2. 7 CFR 1714.5 - Determination of interest rates on municipal rate loans.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Determination of interest rates on municipal rate... General § 1714.5 Determination of interest rates on municipal rate loans. (a) RUS will post on the RUS website, Electric Program HomePage, a schedule of interest rates for municipal rate loans at the beginning...

  3. The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a Screening Tool.

    Science.gov (United States)

    Bastiaens, Leo; Galus, James

    2018-03-01

    The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure was developed to aid clinicians with a dimensional assessment of psychopathology; however, this measure resembles a screening tool for several symptomatic domains. The objective of the current study was to examine the basic parameters of sensitivity, specificity, positive and negative predictive power of the measure as a screening tool. One hundred and fifty patients in a correctional community center filled out the measure prior to a psychiatric evaluation, including the Mini International Neuropsychiatric Interview screen. The above parameters were calculated for the domains of depression, mania, anxiety, and psychosis. The results showed that the sensitivity and positive predictive power of the studied domains was poor because of a high rate of false positive answers on the measure. However, when the lowest threshold on the Cross-Cutting Symptom Measure was used, the sensitivity of the anxiety and psychosis domains and the negative predictive values for mania, anxiety and psychosis were good. In conclusion, while it is foreseeable that some clinicians may use the DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a screening tool, it should not be relied on to identify positive findings. It functioned well in the negative prediction of mania, anxiety and psychosis symptoms.

  4. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    Science.gov (United States)

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-04-12

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  5. A Negative Selection Algorithm Based on Hierarchical Clustering of Self Set and its Application in Anomaly Detection

    Directory of Open Access Journals (Sweden)

    Wen Chen

    2011-08-01

    Full Text Available A negative selection algorithm based on the hierarchical clustering of self set HC-RNSA is introduced in this paper. Several strategies are applied to improve the algorithm performance. First, the self data set is replaced by the self cluster centers to compare with the detector candidates in each cluster level. As the number of self clusters is much less than the self set size, the detector generation efficiency is improved. Second, during the detector generation process, the detector candidates are restricted to the lower coverage space to reduce detector redundancy. In the article, the problem that the distances between antigens coverage to a constant value in the high dimensional space is analyzed, accordingly the Principle Component Analysis (PCA method is used to reduce the data dimension, and the fractional distance function is employed to enhance the distinctiveness between the self and non-self antigens. The detector generation procedure is terminated when the expected non-self coverage is reached. The theory analysis and experimental results demonstrate that the detection rate of HC-RNSA is higher than that of the traditional negative selection algorithms while the false alarm rate and time cost are reduced.

  6. Estimating error rates for firearm evidence identifications in forensic science

    Science.gov (United States)

    Song, John; Vorburger, Theodore V.; Chu, Wei; Yen, James; Soons, Johannes A.; Ott, Daniel B.; Zhang, Nien Fan

    2018-01-01

    Estimating error rates for firearm evidence identification is a fundamental challenge in forensic science. This paper describes the recently developed congruent matching cells (CMC) method for image comparisons, its application to firearm evidence identification, and its usage and initial tests for error rate estimation. The CMC method divides compared topography images into correlation cells. Four identification parameters are defined for quantifying both the topography similarity of the correlated cell pairs and the pattern congruency of the registered cell locations. A declared match requires a significant number of CMCs, i.e., cell pairs that meet all similarity and congruency requirements. Initial testing on breech face impressions of a set of 40 cartridge cases fired with consecutively manufactured pistol slides showed wide separation between the distributions of CMC numbers observed for known matching and known non-matching image pairs. Another test on 95 cartridge cases from a different set of slides manufactured by the same process also yielded widely separated distributions. The test results were used to develop two statistical models for the probability mass function of CMC correlation scores. The models were applied to develop a framework for estimating cumulative false positive and false negative error rates and individual error rates of declared matches and non-matches for this population of breech face impressions. The prospect for applying the models to large populations and realistic case work is also discussed. The CMC method can provide a statistical foundation for estimating error rates in firearm evidence identifications, thus emulating methods used for forensic identification of DNA evidence. PMID:29331680

  7. Reduced False Memory after Sleep

    Science.gov (United States)

    Fenn, Kimberly M.; Gallo, David A.; Margoliash, Daniel; Roediger, Henry L., III; Nusbaum, Howard C.

    2009-01-01

    Several studies have shown that sleep contributes to the successful maintenance of previously encoded information. This research has focused exclusively on memory for studied events, as opposed to false memories. Here we report three experiments showing that sleep reduces false memories in the Deese-Roediger-McDermott (DRM) memory illusion. False…

  8. Can false memory for critical lures occur without conscious awareness of list words?

    Science.gov (United States)

    Sadler, Daniel D; Sodmont, Sharon M; Keefer, Lucas A

    2018-02-01

    We examined whether the DRM false memory effect can occur when list words are presented below the perceptual identification threshold. In four experiments, subjects showed robust veridical memory for studied words and false memory for critical lures when masked list words were presented at exposure durations of 43 ms per word. Shortening the exposure duration to 29 ms virtually eliminated veridical recognition of studied words and completely eliminated false recognition of critical lures. Subjective visibility ratings in Experiments 3a and 3b support the assumption that words presented at 29 ms were subliminal for most participants, but were occasionally experienced with partial awareness by participants with higher perceptual awareness. Our results indicate that a false memory effect does not occur in the absence of conscious awareness of list words, but it does occur when word stimuli are presented at an intermediate level of visibility. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Word type effects in false recall: concrete, abstract, and emotion word critical lures.

    Science.gov (United States)

    Bauer, Lisa M; Olheiser, Erik L; Altarriba, Jeanette; Landi, Nicole

    2009-01-01

    Previous research has demonstrated that definable qualities of verbal stimuli have implications for memory. For example, the distinction between concrete and abstract words has led to the finding that concrete words have an advantage in memory tasks (i.e., the concreteness effect). However, other word types, such as words that label specific human emotions, may also affect memory processes. This study examined the effects of word type on the production of false memories by using a list-learning false memory paradigm. Participants heard lists of words that were highly associated to nonpresented concrete, abstract, or emotion words (i.e., the critical lures) and then engaged in list recall. Emotion word critical lures were falsely recalled at a significantly higher rate (with the effect carried by the positively valenced critical lures) than concrete and abstract critical lures. These findings suggest that the word type variable has implications for our understanding of the mechanisms that underlie recall and false recall.

  10. 5 CFR 531.245 - Computing locality rates and special rates for GM employees.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Computing locality rates and special... Gm Employees § 531.245 Computing locality rates and special rates for GM employees. Locality rates and special rates are computed for GM employees in the same manner as locality rates and special rates...

  11. Bandwagon voting or false-consensus effect in voting experiments? First results and methodological limits

    OpenAIRE

    Bischoff, Ivo; Egbert, Henrik

    2008-01-01

    In an experiment designed to test for expressive voting, Tyran (JPubEc 2004) found a strong positive correlation between the participants' approval to a proposal to donate money for charity and their expected approval rate for fellow voters. This phenomenon can be due to a bandwagon effect or a false consensus effect. Both effects have been reported for voting decisions in the social science literature. Redoing Tyran's experiment and adding new treatments, we provide evidence for a false cons...

  12. Negatively-biased credulity and the cultural evolution of beliefs.

    Science.gov (United States)

    Fessler, Daniel M T; Pisor, Anne C; Navarrete, Carlos David

    2014-01-01

    The functions of cultural beliefs are often opaque to those who hold them. Accordingly, to benefit from cultural evolution's ability to solve complex adaptive problems, learners must be credulous. However, credulity entails costs, including susceptibility to exploitation, and effort wasted due to false beliefs. One determinant of the optimal level of credulity is the ratio between the costs of two types of errors: erroneous incredulity (failing to believe information that is true) and erroneous credulity (believing information that is false). This ratio can be expected to be asymmetric when information concerns hazards, as the costs of erroneous incredulity will, on average, exceed the costs of erroneous credulity; no equivalent asymmetry characterizes information concerning benefits. Natural selection can therefore be expected to have crafted learners' minds so as to be more credulous toward information concerning hazards. This negatively-biased credulity extends general negativity bias, the adaptive tendency for negative events to be more salient than positive events. Together, these biases constitute attractors that should shape cultural evolution via the aggregated effects of learners' differential retention and transmission of information. In two studies in the U.S., we demonstrate the existence of negatively-biased credulity, and show that it is most pronounced in those who believe the world to be dangerous, individuals who may constitute important nodes in cultural transmission networks. We then document the predicted imbalance in cultural content using a sample of urban legends collected from the Internet and a sample of supernatural beliefs obtained from ethnographies of a representative collection of the world's cultures, showing that beliefs about hazards predominate in both.

  13. The effect of cognitive load on hemispheric asymmetries in true and false memory.

    Science.gov (United States)

    Tat, Michael J; Azuma, Tamiko

    2016-01-01

    Studies examining hemispheric asymmetries in false memory have shown that the right hemisphere (RH) is more susceptible to false memories compared to the left hemisphere (LH). Theories suggest that hemispheric asymmetries in true and false memory may be due to differences in representational coding and the use of top-down mechanisms in each hemisphere. In the current study, the Deese-Roediger-McDermott false memory paradigm was used in conjunction with divided visual field presentation to examine the role of top-down mechanisms in hemispheric asymmetries of true and false memory. In Experiment 1, participants studied lists of related words while completing secondary cognitive load tasks. In Experiment 2, the secondary tasks were administered during memory retrieval instead of memory encoding. Results revealed that cognitive loads imposed during the study phase influenced veridical memory in the LH more than the RH, but cognitive loads imposed during retrieval did not influence veridical memory in either hemisphere. Surprisingly, false memory rates were not influenced by cognitive loads and were higher in the LH. These data provide evidence that, at least for veridical memory, top-down control mechanisms are used more readily for the encoding of information into memory in the LH compared to the RH.

  14. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Directory of Open Access Journals (Sweden)

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  15. 15 CFR 700.3 - Priority ratings and rated orders.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Priority ratings and rated orders. 700.3 Section 700.3 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE NATIONAL SECURITY INDUSTRIAL BASE...

  16. cn.FARMS: a latent variable model to detect copy number variations in microarray data with a low false discovery rate.

    Science.gov (United States)

    Clevert, Djork-Arné; Mitterecker, Andreas; Mayr, Andreas; Klambauer, Günter; Tuefferd, Marianne; De Bondt, An; Talloen, Willem; Göhlmann, Hinrich; Hochreiter, Sepp

    2011-07-01

    Cost-effective oligonucleotide genotyping arrays like the Affymetrix SNP 6.0 are still the predominant technique to measure DNA copy number variations (CNVs). However, CNV detection methods for microarrays overestimate both the number and the size of CNV regions and, consequently, suffer from a high false discovery rate (FDR). A high FDR means that many CNVs are wrongly detected and therefore not associated with a disease in a clinical study, though correction for multiple testing takes them into account and thereby decreases the study's discovery power. For controlling the FDR, we propose a probabilistic latent variable model, 'cn.FARMS', which is optimized by a Bayesian maximum a posteriori approach. cn.FARMS controls the FDR through the information gain of the posterior over the prior. The prior represents the null hypothesis of copy number 2 for all samples from which the posterior can only deviate by strong and consistent signals in the data. On HapMap data, cn.FARMS clearly outperformed the two most prevalent methods with respect to sensitivity and FDR. The software cn.FARMS is publicly available as a R package at http://www.bioinf.jku.at/software/cnfarms/cnfarms.html.

  17. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    Science.gov (United States)

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  18. Fluctuating confidence: the dynamic consequences of true/false affirmatives and denials on how a listener appraises their personal past.

    Science.gov (United States)

    Davis, Jolee; Bayantemur, Sharon Y; Seecharan, Sasha; Unger, Leslie D; Hellgren, Johanna; Stone, Charles B

    2018-08-01

    The present study examined the mnemonic consequences of true/false denials and affirmatives on how a listener appraises their personal past. To this end, participants (listeners) rated the extent to which they were confident certain events occurred during their childhood. They rated these events both before and after a confederate (speaker) denied or affirmed the occurrence of four different childhood events each, for a total of eight "rehearsed" events. For each set (denials and affirmatives) of events, half were true and half were false. In turn, this created four types of events (two each): true denials, true affirmatives, false denials, and false affirmatives. Additionally, half of the participants were told that the speaker was provided independent information about the veracity of the event's occurrence ("expert" condition). Overall, listeners were less confident in the occurrence of false denial events, but more so when they believed the speaker to be more knowledgeable of the listeners memories, more confident in false affirmative events and, counter intuitively, more confident in the occurrence of true denial events. These results underscore the importance of a nuanced approach to the mnemonic consequences of true and false denials and affirmations in the course of social interactions.

  19. A novel one-class SVM based negative data sampling method for reconstructing proteome-wide HTLV-human protein interaction networks.

    Science.gov (United States)

    Mei, Suyu; Zhu, Hao

    2015-01-26

    Protein-protein interaction (PPI) prediction is generally treated as a problem of binary classification wherein negative data sampling is still an open problem to be addressed. The commonly used random sampling is prone to yield less representative negative data with considerable false negatives. Meanwhile rational constraints are seldom exerted on model selection to reduce the risk of false positive predictions for most of the existing computational methods. In this work, we propose a novel negative data sampling method based on one-class SVM (support vector machine, SVM) to predict proteome-wide protein interactions between HTLV retrovirus and Homo sapiens, wherein one-class SVM is used to choose reliable and representative negative data, and two-class SVM is used to yield proteome-wide outcomes as predictive feedback for rational model selection. Computational results suggest that one-class SVM is more suited to be used as negative data sampling method than two-class PPI predictor, and the predictive feedback constrained model selection helps to yield a rational predictive model that reduces the risk of false positive predictions. Some predictions have been validated by the recent literature. Lastly, gene ontology based clustering of the predicted PPI networks is conducted to provide valuable cues for the pathogenesis of HTLV retrovirus.

  20. Negative energy radiation and the second law of thermodynamics

    International Nuclear Information System (INIS)

    Deutsch, D.; Ottewill, A.C.; Sciama, D.W.

    1982-01-01

    It has been suggested that the second law of thermodynamics can be violated by processes involving the absorption by a hot body of negative energy fluxes of quantum origin. We show that this suggestion is false in the case of the process recently proposed by Davies, at least for a simple model of the hot body involved. Such a model body would not in fact be able to absorb the negative energy flux incident on it. We suggest that our argument can be generalized, and that there is no reason to doubt the second law. (orig.)

  1. 39 CFR 3010.25 - Limitation on unused rate adjustment authority rate adjustments.

    Science.gov (United States)

    2010-07-01

    ... only be applied together with inflation-based limitation rate adjustments or when inflation-based... used in lieu of an inflation-based limitation rate adjustment. ... 39 Postal Service 1 2010-07-01 2010-07-01 false Limitation on unused rate adjustment authority...

  2. Distress attributed to negative symptoms in schizophrenia

    NARCIS (Netherlands)

    Selten, JP; Wiersma, D; van den Bosch, RJ

    2000-01-01

    The purpose of the study was to examine (1) to which negative symptoms schizophrenia patients attribute distress and (2) whether clinical variables can predict the levels of reported distress. With the help of a research assistant, 86 hospitalized patients completed a self-rating scale for negative

  3. Detecting false positive sequence homology: a machine learning approach.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Bybee, Seth M

    2016-02-24

    Accurate detection of homologous relationships of biological sequences (DNA or amino acid) amongst organisms is an important and often difficult task that is essential to various evolutionary studies, ranging from building phylogenies to predicting functional gene annotations. There are many existing heuristic tools, most commonly based on bidirectional BLAST searches that are used to identify homologous genes and combine them into two fundamentally distinct classes: orthologs and paralogs. Due to only using heuristic filtering based on significance score cutoffs and having no cluster post-processing tools available, these methods can often produce multiple clusters constituting unrelated (non-homologous) sequences. Therefore sequencing data extracted from incomplete genome/transcriptome assemblies originated from low coverage sequencing or produced by de novo processes without a reference genome are susceptible to high false positive rates of homology detection. In this paper we develop biologically informative features that can be extracted from multiple sequence alignments of putative homologous genes (orthologs and paralogs) and further utilized in context of guided experimentation to verify false positive outcomes. We demonstrate that our machine learning method trained on both known homology clusters obtained from OrthoDB and randomly generated sequence alignments (non-homologs), successfully determines apparent false positives inferred by heuristic algorithms especially among proteomes recovered from low-coverage RNA-seq data. Almost ~42 % and ~25 % of predicted putative homologies by InParanoid and HaMStR respectively were classified as false positives on experimental data set. Our process increases the quality of output from other clustering algorithms by providing a novel post-processing method that is both fast and efficient at removing low quality clusters of putative homologous genes recovered by heuristic-based approaches.

  4. Consensus review of discordant findings maximizes cancer detection rate in double-reader screening mammography: Irish National Breast Screening Program experience.

    Science.gov (United States)

    Shaw, Colette M; Flanagan, Fidema L; Fenlon, Helen M; McNicholas, Michelle M

    2009-02-01

    To assesses consensus review of discordant screening mammography findings in terms of its sensitivity, safety, and effect on overall performance in the first 6 years of operation of the Irish National Breast Screening Program (NBSP). Women who participated in the Irish NBSP gave written informed consent for use of their data for auditing purposes. Local ethics committee approval was obtained. The study population consisted of women who participated in the Irish NBSP and underwent initial screening mammography at one of the two screening centers serving the eastern part of Ireland between 2000 and 2005. Independent double reading of mammograms was performed. When the readers disagreed regarding referral, the case was reviewed by a consensus panel. Of the 128 569 screenings performed, 1335 (1%) were discussed by consensus. Of the 1335 cases discussed by consensus, 606 (45.39%) were recalled for further assessment. This resulted in an overall recall rate of 4.41%. In those recalled to assessment, 71 cases of malignant disease were diagnosed (ductal carcinoma in situ, n = 24; invasive cancer, n = 47). The remaining 729 patients were returned to biennial screening. Of these 729 patients, seven had false-negative findings that were identified in the subsequent screening round. Use of the highest reader recall method, in which a patient is recalled if her findings are deemed abnormal by either reader, could potentially increase the cancer detection rate by 0.6 per 1000 women screened but would increase the recall rate by 12.69% and the number of false-positive findings by 15.37%. The consensus panel identified 71 (7.33%) of 968 cancers diagnosed. Consensus review substantially reduced the number of cases recalled and was associated with a low false-negative rate.

  5. Verbal instructions targeting valence alter negative conditional stimulus evaluations (but do not affect reinstatement rates).

    Science.gov (United States)

    Luck, Camilla C; Lipp, Ottmar V

    2018-02-01

    Negative conditional stimulus (CS) valence acquired during fear conditioning may enhance fear relapse and is difficult to remove as it extinguishes slowly and does not respond to the instruction that unconditional stimulus (US) presentations will cease. We examined whether instructions targeting CS valence would be more effective. In Experiment 1, an image of one person (CS+) was paired with an aversive US, while another (CS-) was presented alone. After acquisition, participants were given positive information about the CS+ poser and negative information about the CS- poser. Instructions reversed the pattern of differential CS valence present during acquisition and eliminated differential electrodermal responding. In Experiment 2, we compared positive and negative CS revaluation by providing positive/negative information about the CS+ and neutral information about CS-. After positive revaluation, differential valence was removed and differential electrodermal responding remained intact. After negative revaluation, differential valence was strengthened and differential electrodermal responding was eliminated. Unexpectedly, the instructions did not affect the reinstatement of differential electrodermal responding.

  6. On the susceptibility of adaptive memory to false memory illusions

    OpenAIRE

    Howe, M. L.; Derbish, M. H.

    2010-01-01

    Previous research has shown that survival-related processing of word lists enhances retention for that material. However, the claim that survival-related memories are more accurate has only been examined when true recall and recognition of neutral material has been measured. In the current experiments, we examined the adaptive memory superiority effect for different types of processing and material, measuring accuracy more directly by comparing true and false recollection rates. Survival-rela...

  7. Age differences in autobiographical memories of negative events.

    Science.gov (United States)

    Boals, Adriel; Hayslip, Bert; Banks, Jonathan B

    2014-01-01

    This study examined whether older adults recollect autobiographical memories of negative events so as to minimize unpleasant emotions to a greater extent than do younger adults. A sample of healthy older adults (N = 126) and younger adults (N = 119) completed the Autobiographical Memory Questionnaire and a measure of PTSD symptoms in response to their most negative recalled event. Results supported the hypothesis that older adults rated their negative memories as having: 1) less of a sense of traveling back to the time the event occurred, 2) less associated visceral emotional reactions, 3) fewer associated negative emotions, and 4) fewer PTSD symptoms, all relative to younger adults. In addition, older adults exhibited higher ratings of belief in accuracy, higher ratings that the memory comes as a coherent story, and more associated positive emotions, again all relative to younger adults. After controlling for differences between the types of events younger and older adults reported and how long ago the event occurred, the above age differences remained statistically significant, though the effect sizes were attenuated in some cases. These results are consistent in their support for the positivity effect, and suggest that older adults modify their recollections of negative events in a manner that is emotionally adaptive for them.

  8. Priming analogical reasoning with false memories.

    Science.gov (United States)

    Howe, Mark L; Garner, Sarah R; Threadgold, Emma; Ball, Linden J

    2015-08-01

    Like true memories, false memories are capable of priming answers to insight-based problems. Recent research has attempted to extend this paradigm to more advanced problem-solving tasks, including those involving verbal analogical reasoning. However, these experiments are constrained inasmuch as problem solutions could be generated via spreading activation mechanisms (much like false memories themselves) rather than using complex reasoning processes. In three experiments we examined false memory priming of complex analogical reasoning tasks in the absence of simple semantic associations. In Experiment 1, we demonstrated the robustness of false memory priming in analogical reasoning when backward associative strength among the problem terms was eliminated. In Experiments 2a and 2b, we extended these findings by demonstrating priming on newly created homonym analogies that can only be solved by inhibiting semantic associations within the analogy. Overall, the findings of the present experiments provide evidence that the efficacy of false memory priming extends to complex analogical reasoning problems.

  9. False traumatic aneurysms and arteriovenous fistulas: retrospective analysis.

    Science.gov (United States)

    Davidovic, Lazar B; Banzić, Igor; Rich, Norman; Dragaš, Marko; Cvetkovic, Slobodan D; Dimic, Andrija

    2011-06-01

    The purpose of this study was to analyze the incidence, clinical presentation, diagnosis, and treatment of false traumatic aneurysms and arteriovenous fistulas as well as the outcomes of the patients. A retrospective, 16-year survey has been conducted regarding the cases of patients who underwent surgery for false traumatic aneurysms (FTA) of arteries and traumatic arteriovenous fistulas (TAVF). Patients with iatrogenic AV fistulas and iatrogenic false aneurysms were excluded from the study. There were 36 patients with TAVF and 47 with FTA. In all, 73 (87.95%) were male, and 10 (12.05%) were female, with an average age of 36.93 years (13-82 years). In 25 (29.76%) cases TAVF and FTA appeared combat-related, and 59 (70.24%) were in noncombatants. The average of all intervals between the injury and surgery was 919. 8 days (1 day to 41 years) for FTA and 396.6 days (1 day to 9 years) for TAVF. Most of the patients in both groups were surgically treated during the first 30 days after injury. One patient died on the fourth postoperative day. There were two early complications. The early patency rate was 83.34%, and limb salvage was 100%. There were no recurrent AV fistulas that required additional operations. Because of their history of severe complications, FTA and TAV fistulas require prompt treatment. The treatment is simpler if there is only a short interval between the injury and the operation. Surgical endovascular repair is mostly indicated.

  10. Shake-flask test for determination of biodegradation rates of 14C-labelled chemicals at low concentrations in surface water systems

    DEFF Research Database (Denmark)

    Ingerslev, F.; Nyholm, Niels

    2000-01-01

    A simple shake-flask surface water biodegradability die away test with C-14-labeled chemicals added to microgram per liter concentrations (usually 1-100 mu g/L) is described and evaluated. The aim was to provide information on biodegradation behavior and kinetic rates at environmental (low...... regular reinoculation with freshly collected surface water could, however, overcome the problems of false-negative results. (C) 2000 Academic Press....

  11. Confidence Intervals for Asbestos Fiber Counts: Approximate Negative Binomial Distribution.

    Science.gov (United States)

    Bartley, David; Slaven, James; Harper, Martin

    2017-03-01

    The negative binomial distribution is adopted for analyzing asbestos fiber counts so as to account for both the sampling errors in capturing only a finite number of fibers and the inevitable human variation in identifying and counting sampled fibers. A simple approximation to this distribution is developed for the derivation of quantiles and approximate confidence limits. The success of the approximation depends critically on the use of Stirling's expansion to sufficient order, on exact normalization of the approximating distribution, on reasonable perturbation of quantities from the normal distribution, and on accurately approximating sums by inverse-trapezoidal integration. Accuracy of the approximation developed is checked through simulation and also by comparison to traditional approximate confidence intervals in the specific case that the negative binomial distribution approaches the Poisson distribution. The resulting statistics are shown to relate directly to early research into the accuracy of asbestos sampling and analysis. Uncertainty in estimating mean asbestos fiber concentrations given only a single count is derived. Decision limits (limits of detection) and detection limits are considered for controlling false-positive and false-negative detection assertions and are compared to traditional limits computed assuming normal distributions. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2017.

  12. [Molecular beacon based PNA-FISH method combined with fluorescence scanning for rapid detection of Listeria monocytogenes].

    Science.gov (United States)

    Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen

    2016-07-04

    To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.

  13. Does a Negative Triple Test Reduce the Rate of Negative Appendectomy in Adults?

    Directory of Open Access Journals (Sweden)

    Mahmoud F. Sakr

    2012-08-01

    Results: Sixty-seven patients (65.9% were female and 35 (34.1% were male. Their ages ranged between 16 and 49 years (mean 27.5 years. Most patients (87.3% had their symptoms for 12-36 hours before hospital admission. The mean values for TLC, NP, and CRP were 7,573/ and micro;L, 54.53%, and 0.61 mg/L, respectively. Of the 102 patients with NTT, 101 (99% proved not to have appendiceal inflammation (NPV=99%. Only 39 patients were operated upon, of whom 38 (97.4% had a normal appendix, and the remaining 63 patients were either discharged (n=47 or referred to other specialties (n=16. There were significantly more women (76.3%, 29/38 with negative appendectomy than men (24.7%, 9/38 (X2= 21.1, p=0.0001. Gynecological causes were the most common (60.5%, 23/38 and in 11 cases, the exact etiology could not be identified. Conclusions: From the data presented, it may be concluded that TLC, NP and CRP blood levels (triple test should be measured upon hospital admission of adult patients with clinically suspected acute appendicitis. If used judiciously, they may spare the group of patients with an NTT an unnecessary surgical operation, hence markedly reducing the NAR with its potential risks. [Arch Clin Exp Surg 2012; 1(4.000: 229-236

  14. False memory ≠ false memory: DRM errors are unrelated to the misinformation effect.

    Directory of Open Access Journals (Sweden)

    James Ost

    Full Text Available The DRM method has proved to be a popular and powerful, if controversial, way to study 'false memories'. One reason for the controversy is that the extent to which the DRM effect generalises to other kinds of memory error has been neither satisfactorily established nor subject to much empirical attention. In the present paper we contribute data to this ongoing debate. One hundred and twenty participants took part in a standard misinformation effect experiment, in which they watched some CCTV footage, were exposed to misleading post-event information about events depicted in the footage, and then completed free recall and recognition tests. Participants also completed a DRM test as an ostensibly unrelated filler task. Despite obtaining robust misinformation and DRM effects, there were no correlations between a broad range of misinformation and DRM effect measures (mean r  = -.01. This was not due to reliability issues with our measures or a lack of power. Thus DRM 'false memories' and misinformation effect 'false memories' do not appear to be equivalent.

  15. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    Science.gov (United States)

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  16. Is it wise to protect false targets?

    International Nuclear Information System (INIS)

    Levitin, Gregory; Hausken, Kjell

    2011-01-01

    The paper considers a system consisting of genuine elements and false targets that cannot be distinguished by the attacker's observation. The false targets can be destroyed with much less effort than the genuine elements. We show that even when an attacker cannot distinguish between the genuine elements and the false targets, in many cases it can enhance the attack efficiency using a double attack strategy in which it tries first to eliminate with minimal effort as many false targets as possible in the first attack and then distributes its entire remaining resource among all surviving targets in the second attack. The model for evaluating the system vulnerability in the double attack is suggested for a single genuine element, and multiple genuine elements configured in parallel or in series. This model assumes that in both attacks the attacking resource is distributed evenly among the attacked targets. The defender can optimize its limited resource distribution between deploying more false targets and protecting them better. The attacker can optimize its limited resource distribution between two attacks. The defense strategy is analyzed based on a two period minmax game. A numerical procedure is suggested that allows the defender to find the optimal resource distribution between deploying and protecting the false targets. The methodology of optimal attack and defense strategies analysis is demonstrated. It is shown that protecting the false targets may reduce the efficiency of the double attack strategy and make this strategy ineffective in situations with low contest intensity and few false targets. - Highlights: ► The efficiency of the double attack tactics against using false targets is analyzed. ► The role of the false target protection in system survivability enhancement is shown. ► The resource distribution between deploying more false targets and protecting them better is optimized. ► Both series and parallel systems are considered.

  17. Need for Cognition and False Memory: Can One's Natural Processing Style Be Manipulated by External Factors?

    Science.gov (United States)

    Wootan, Samantha S; Leding, Juliana K

    2015-01-01

    The purpose of this experiment was to provide an enhanced understanding of need for cognition (NFC) and its influence on one's memory accuracy. People who are high in NFC tend to put more cognitive effort into their mental processes than their low-NFC counterparts. To determine whether one's natural processing tendencies, as determined by NFC, can be influenced by external factors, manipulations to levels of processing were added. Participants viewed word lists from the Deese-Roediger-McDermott (DRM) paradigm and were instructed to process half of the DRM lists deeply and the other half shallowly. After all the lists were presented, participants completed 3 successive recall tests. The deep processing condition produced higher rates of false memories for both NFC groups than the shallow processing condition. In addition, the high-NFC group produced higher rates of target recall in both the deep and shallow conditions than the low-NFC group. However, the high-NFC group also produced higher rates of false recall for the shallowly processed lists. These data indicate that high-NFC people exhibit enhanced target recall for word lists, which may come at the expense of overall accuracy due to the increase of false recall.

  18. Cross-cultural decoding of positive and negative nonlinguistic emotion vocalizations

    Directory of Open Access Journals (Sweden)

    Petri eLaukka

    2013-07-01

    Full Text Available Which emotions are associated with universally recognized nonverbal signals? We address this issue by examining how reliably nonlinguistic vocalizations (affect bursts can convey emotions across cultures. Actors from India, Kenya, Singapore and USA were instructed to produce vocalizations that would convey 9 positive and 9 negative emotions to listeners. The vocalizations were judged by Swedish listeners using a within-valence forced-choice procedure, where positive and negative emotions were judged in separate experiments. Results showed that listeners could recognize a wide range of positive and negative emotions with accuracy above chance. For positive emotions, we observed the highest recognition rates for relief, followed by lust, interest, serenity and positive surprise, with affection and pride receiving the lowest recognition rates. Anger, disgust, fear, sadness and negative surprise received the highest recognition rates for negative emotions, with the lowest rates observed for guilt and shame. By way of summary, results showed that the voice can reveal both basic emotions and several positive emotions other than happiness across cultures, but self-conscious emotions such as guilt, pride, and shame seem not to be well recognized from nonlinguistic vocalizations.

  19. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    International Nuclear Information System (INIS)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Karssemeijer, Nico; Heeten, Gerard den

    2016-01-01

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  20. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico [Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen 6525 GA (Netherlands); Heeten, Gerard den [The National Training Centre for Breast Cancer Screening, Nijmegen 6503 GJ, The Netherlands and Department of Radiology, Amsterdam Medical Center, Amsterdam 1100 DD (Netherlands)

    2016-04-15

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  1. Semantic priming, not repetition priming, is to blame for false hearing.

    Science.gov (United States)

    Rogers, Chad S

    2017-08-01

    Contextual and sensory information are combined in speech perception. Conflict between the two can lead to false hearing, defined as a high-confidence misidentification of a spoken word. Rogers, Jacoby, and Sommers (Psychology and Aging, 27(1), 33-45, 2012) found that older adults are more susceptible to false hearing than are young adults, using a combination of semantic priming and repetition priming to create context. In this study, the type of context (repetition vs. sematic priming) responsible for false hearing was examined. Older and young adult participants read and listened to a list of paired associates (e.g., ROW-BOAT) and were told to remember the pairs for a later memory test. Following the memory test, participants identified words masked in noise that were preceded by a cue word in the clear. Targets were semantically associated to the cue (e.g., ROW-BOAT), unrelated to the cue (e.g., JAW-PASS), or phonologically related to a semantic associate of the cue (e.g., ROW-GOAT). How often each cue word and its paired associate were presented prior to the memory test was manipulated (0, 3, or 5 times) to test effects of repetition priming. Results showed repetitions had no effect on rates of context-based listening or false hearing. However, repetition did significantly increase sensory information as a basis for metacognitive judgments in young and older adults. This pattern suggests that semantic priming dominates as the basis for false hearing and highlights context and sensory information operating as qualitatively different bases for listening and metacognition.

  2. Provider-Initiated Patient Satisfaction Reporting Yields Improved Physician Ratings Relative to Online Rating Websites.

    Science.gov (United States)

    Ricciardi, Benjamin F; Waddell, Brad S; Nodzo, Scott R; Lange, Jeffrey; Nocon, Allina A; Amundsen, Spencer; Tarity, T David; McLawhorn, Alexander S

    2017-09-01

    Recently, providers have begun to publicly report the results of patient satisfaction surveys from their practices. However, these outcomes have never been compared with the findings of commercial online physician rating websites. The goals of the current study were to (1) compare overall patient satisfaction ratings for orthopedic surgeons derived from provider-based third-party surveys with existing commercial physician rating websites and (2) determine the association between patient ratings and provider characteristics. The authors identified 12 institutions that provided publicly available patient satisfaction outcomes derived from third-party surveys for their orthopedic surgeons as of August 2016. Orthopedic surgeons at these institutions were eligible for inclusion (N=340 surgeons). Provider characteristics were recorded from publicly available data. Four high-traffic commercial online physician rating websites were identified: Healthgrades.com, UCompareHealthCare.com, Vitals.com, and RateMDs.com. For each surgeon, overall ratings (on a scale of 1-5), total number of ratings, and percentage of negative ratings were compared between provider-initiated internal ratings and each commercial online website. Associations between baseline factors and overall physician ratings and negative ratings were assessed. Provider-initiated internal patient satisfaction ratings showed a greater number of overall patient ratings, higher overall patient satisfaction ratings, and a lower percentage of negative comments compared with commercial online physician rating websites. A greater number of years in practice had a weak association with lower internal ratings, and an academic practice setting and a location in the Northeast were protective factors for negative physician ratings. Compared with commercial online physician rating websites, provider-initiated patient satisfaction ratings of orthopedic surgeons appear to be more favorable, with greater numbers of responses

  3. Negatively-Biased Credulity and the Cultural Evolution of Beliefs

    Science.gov (United States)

    Fessler, Daniel M. T.; Pisor, Anne C.; Navarrete, Carlos David

    2014-01-01

    The functions of cultural beliefs are often opaque to those who hold them. Accordingly, to benefit from cultural evolution’s ability to solve complex adaptive problems, learners must be credulous. However, credulity entails costs, including susceptibility to exploitation, and effort wasted due to false beliefs. One determinant of the optimal level of credulity is the ratio between the costs of two types of errors: erroneous incredulity (failing to believe information that is true) and erroneous credulity (believing information that is false). This ratio can be expected to be asymmetric when information concerns hazards, as the costs of erroneous incredulity will, on average, exceed the costs of erroneous credulity; no equivalent asymmetry characterizes information concerning benefits. Natural selection can therefore be expected to have crafted learners’ minds so as to be more credulous toward information concerning hazards. This negatively-biased credulity extends general negativity bias, the adaptive tendency for negative events to be more salient than positive events. Together, these biases constitute attractors that should shape cultural evolution via the aggregated effects of learners’ differential retention and transmission of information. In two studies in the U.S., we demonstrate the existence of negatively-biased credulity, and show that it is most pronounced in those who believe the world to be dangerous, individuals who may constitute important nodes in cultural transmission networks. We then document the predicted imbalance in cultural content using a sample of urban legends collected from the Internet and a sample of supernatural beliefs obtained from ethnographies of a representative collection of the world’s cultures, showing that beliefs about hazards predominate in both. PMID:24736596

  4. Negatively-biased credulity and the cultural evolution of beliefs.

    Directory of Open Access Journals (Sweden)

    Daniel M T Fessler

    Full Text Available The functions of cultural beliefs are often opaque to those who hold them. Accordingly, to benefit from cultural evolution's ability to solve complex adaptive problems, learners must be credulous. However, credulity entails costs, including susceptibility to exploitation, and effort wasted due to false beliefs. One determinant of the optimal level of credulity is the ratio between the costs of two types of errors: erroneous incredulity (failing to believe information that is true and erroneous credulity (believing information that is false. This ratio can be expected to be asymmetric when information concerns hazards, as the costs of erroneous incredulity will, on average, exceed the costs of erroneous credulity; no equivalent asymmetry characterizes information concerning benefits. Natural selection can therefore be expected to have crafted learners' minds so as to be more credulous toward information concerning hazards. This negatively-biased credulity extends general negativity bias, the adaptive tendency for negative events to be more salient than positive events. Together, these biases constitute attractors that should shape cultural evolution via the aggregated effects of learners' differential retention and transmission of information. In two studies in the U.S., we demonstrate the existence of negatively-biased credulity, and show that it is most pronounced in those who believe the world to be dangerous, individuals who may constitute important nodes in cultural transmission networks. We then document the predicted imbalance in cultural content using a sample of urban legends collected from the Internet and a sample of supernatural beliefs obtained from ethnographies of a representative collection of the world's cultures, showing that beliefs about hazards predominate in both.

  5. When negation is not negation

    OpenAIRE

    Milicevic, Nataša

    2008-01-01

    In this paper I will discuss the formation of different types of yes/no questions in Serbian (examples in (1)), focusing on the syntactically and semantically puzzling example (1d), which involves the negative auxiliary inversion. Although there is a negative marker on the fronted auxiliary, the construction does not involve sentential negation. This coincides with the fact that the negative quantifying NPIs cannot be licensed. The question formation and sentential negation have similar synta...

  6. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  7. Systemic True False

    African Journals Online (AJOL)

    Preferred Customer

    ):. (a). (b). (c). (d). Answer: True systemics are (b & c); False Systemics (a & d). For more examples, see (10 and 11). Na2O2. NaCl. Na. HCl heat /excess. (O). 300°C electrolysis. (molten). NaOH. NaCl. Na. HCl. H2O electrolysis. (solution). NaCl.

  8. Negative incidental emotions augment fairness sensitivity.

    Science.gov (United States)

    Liu, Cuizhen; Chai, Jing Wen; Yu, Rongjun

    2016-04-22

    Previous studies have shown that task-unrelated emotions induced incidentally exert carryover effects on individuals' subsequent decisions in financial negotiations. However, the specificity of these emotion effects are not clear. In three experiments, we systematically investigated the role of seven transiently induced basic emotions (disgust, sadness, anger, fear, happiness, surprise and neutral) on rejection of unfair offers using the ultimatum game. We found that all negative emotions (disgust, sadness, anger and fear), but not happiness or surprise, significantly increased rejection rates, suggesting that the effect of incidental negative emotions on fairness is not specific to the type of negative emotion. Our findings highlight the role of fleeting emotions in biasing decision-making processes and suggest that all incidental negative emotions exert similar effects on fairness sensitivity, possibly by potentiating attention towards negative aspects of the situation.

  9. Inflammatory disorders mimicking periprosthetic joint infections may result in false positive α-defensin.

    Science.gov (United States)

    Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne

    2018-02-26

    The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.

  10. Feasibility of Tidal and Ocean Current Energy in False Pass, Aleutian Islands, Alaska final report

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Bruce Albert [Aleutian Pribilof Islands Association, Inc., Anchorage, AK (United States)

    2014-05-07

    , the Project Team developed a conceptual tidal energy project design utilizing ORPC’s TidGen® Power System. While the Project Team has not committed to ORPC technology for future development of a False Pass project, this conceptual design was critical to informing the Project’s economic analysis. The results showed that power from a tidal energy project could be provided to the City of False at a rate at or below the cost of diesel generated electricity and sold to commercial customers at rates competitive with current market rates, providing a stable, flat priced, environmentally sound alternative to the diesel generation currently utilized for energy in the community. The Project Team concluded that with additional grants and private investment a tidal energy project at False Pass is well-positioned to be the first tidal energy project to be developed in Alaska, and the first tidal energy project to be interconnected to an isolated micro grid in the world. A viable project will be a model for similar projects in coastal Alaska.

  11. Acute appendicitis in children: ultrasound and CT findings in negative appendectomy cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Ho; Choi, Young Hun; Kim, Woo Sun; Cheon, Jung-Eun; Kim, In-One [Seoul National University Hospital, Department of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    To decrease the negative appendectomy rate in children, knowledge of the misleading imaging findings on US and CT in negative appendicitis cases is important. To evaluate the negative appendectomy rate and describe the imaging findings of US and CT that lead radiologists to misdiagnose acute appendicitis in children. From 2007 to 2013, 374 children operated for suspected appendicitis were proved to either have acute appendicitis (n = 348) or to be negative for appendicitis (n = 26) on pathological reports. Negative appendectomy rates were compared among imaging modalities, age groups and genders. We retrospectively reviewed US and CT findings from negative appendectomy cases. The overall negative appendectomy rate was 7.0% (26/374). There were no statistically significant differences among the subgroups. The most common misleading presentations on US were sonographic tenderness (9/16, 56%) and non-compressibility (9/16, 56%). The most common misleading finding on CT were the presence of an appendicolith or hyperdense feces (5/12, 42%). Periappendiceal fat inflammation was observed in only one case of negative appendicitis on US and on CT. Radiologists can misdiagnose children with equivocal diameters of appendices as having acute appendicitis when sonographic tenderness or non-compressibility is present on US and when an appendicolith or hyperdense feces is noted on CT. The possibility of negative appendicitis should be borne in mind when periappendiceal fat inflammation is absent or minimal in indeterminate cases. (orig.)

  12. Increasing resistant coagulase negative staphylococci in bovine clinical mastitis.

    Science.gov (United States)

    Moniri, R; Dastehgoli, K; Akramian, A

    2007-08-01

    The aim of this study was to determine Coagulase Negative Staphylococci (CNS) and other bacteria for their resistance to antimicrobial agents approved for the control of pathogens involved in clinical bovine mastitis. This descriptive study was done on 106 milk samples obtained from clinical mastitis in dairy cattle husbandry from April 2006 through August 2006 in Kashan, Iran. From the total of 106 milk samples collected from clinical mastitis, 96 (90.6%) lead to positive culture. Coagulase negative Staphylococci isolated in 51 out of 96 samples (53.1%), Staphylococcus aureus isolated in 21 out of 96 (21.9%), gram negative bacilli isolated in 14 out of 96 (14.6%) and Enterococci isolated in 4 (4.2%). The highest rate of resistant CNS observed to penicillin (56.6%) and the highest rate of sensitivity to enrofloxacin 100%, followed by kanamycin, streptomycin and neomycin, 92.2, 82.3 and 82.3%, respectively. The highest rate of resistance S. aureus exhibited to penicillin (66.6%); while the highest rate of sensitivity showed to trimethoprim-sulphamethoxasole (81%), followed by kanamycin and enrofloxacin both at 76.2%. The highest rate of resistance gram negative bacilli exhibited to ampicillin and erythromycin at 71.4%. Their highest rate of sensitivity observed to enrofloxacin (78.6%), followed by kanamycin, (71.4%). In recent years, CNS is emerging as important minor mastitis pathogens and can be the cause of substantial economic losses. The high resistance rate to penicillin and other antibiotics found in this study emphasize the importance of identification of CNS when a bovine clinical mastitis is present.

  13. Poststaphylococcal coagulase negative reactive arthritis: a case report.

    Science.gov (United States)

    Krasniqi, Xhevdet; Rexhepi, Sylejman; Gashi, Masar; Berisha, Blerim; Abazi, Flora; Koçinaj, Dardan

    2009-12-18

    We report a case of a 49-year-old patient who developed poststaphylococcal coagulase negative reactive arthritis. The woman presented with constitutional symptoms, arthritis, urinary infection and conjunctivitis. The blood culture was positive for the staphylococcal coagulase negative infection. Erythrocyte sedimentation rate and C-reactive protein were elevated, whereas the rheumatoid factor was negative. Radiographic findings confirmed diagnosis of pleuropneumonia, and one year later of chronic asymmetric sacroileitis. Physicians should be aware of possible reactive arthritis after staphylococcal coagulase negative bacteremia.

  14. False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: the problem of biotin intake and related interferences.

    Science.gov (United States)

    Piketty, Marie-Liesse; Polak, Michel; Flechtner, Isabelle; Gonzales-Briceño, Laura; Souberbielle, Jean-Claude

    2017-05-01

    Immunoassays are now commonly used for hormone measurement, in high throughput analytical platforms. Immunoassays are generally robust to interference. However, endogenous analytical error may occur in some patients; this may be encountered in biotin supplementation or in the presence of anti-streptavidin antibody, in immunoassays involving streptavidin-biotin interaction. In these cases, the interference may induce both false positive and false negative results, and simulate a seemingly coherent hormonal profile. It is to be feared that this type of errors will be more frequently observed. This review underlines the importance of keeping close interactions between biologists and clinicians to be able to correlate the hormonal assay results with the clinical picture.

  15. False belief understanding in Cantonese-speaking children.

    Science.gov (United States)

    Tardif, Twila; Wellman, Henry M; Cheung, Kar Man

    2004-11-01

    The present study investigates the performance of 96 Cantonese-speaking three- to five-year-old preschoolers on three false belief tasks - a deceptive object, a change of location, and an unexpected contents task encompassing a variety of task factors. Most importantly, the research examines the possibility that false belief performance depends on specific linguistic factors such as the type of verb used in the test question--an explicitly false vs. a neutral belief verb. Cantonese was chosen as particularly useful for examining this question because it explicitly codes belief status as either neutral (nam5) or false (ji5wai4), and because it offers additional linguistic and cultural contrasts to research conducted on false belief with children learning English and other Indo-European languages. As expected, a strong age effect was found, as well as a significant advantage for children who received the explicit false belief (ji5wai4) wording and for those who were asked to explain rather than predict the protagonist's actions. Interestingly, there was also a strong task difference with children performing better on the deceptive object task than on the other two false belief tasks. We argue that these results point both to universal trajectories in theory of mind development and to interesting, but localized, effects of language and culture on children's false belief understanding.

  16. Sleep loss produces false memories.

    Directory of Open Access Journals (Sweden)

    Susanne Diekelmann

    Full Text Available People sometimes claim with high confidence to remember events that in fact never happened, typically due to strong semantic associations with actually encoded events. Sleep is known to provide optimal neurobiological conditions for consolidation of memories for long-term storage, whereas sleep deprivation acutely impairs retrieval of stored memories. Here, focusing on the role of sleep-related memory processes, we tested whether false memories can be created (a as enduring memory representations due to a consolidation-associated reorganization of new memory representations during post-learning sleep and/or (b as an acute retrieval-related phenomenon induced by sleep deprivation at memory testing. According to the Deese, Roediger, McDermott (DRM false memory paradigm, subjects learned lists of semantically associated words (e.g., "night", "dark", "coal",..., lacking the strongest common associate or theme word (here: "black". Subjects either slept or stayed awake immediately after learning, and they were either sleep deprived or not at recognition testing 9, 33, or 44 hours after learning. Sleep deprivation at retrieval, but not sleep following learning, critically enhanced false memories of theme words. This effect was abolished by caffeine administration prior to retrieval, indicating that adenosinergic mechanisms can contribute to the generation of false memories associated with sleep loss.

  17. The impact of screening-test negative samples not enumerated by MPN

    DEFF Research Database (Denmark)

    Corbellini, Luis Gustavo; Ribeiro Duarte, Ana Sofia; de Knegt, Leonardo

    2015-01-01

    that includes false negative results from the screening, and a third that considers the entire data set. The relative sensitivity of the screening test was also calculated assuming as gold standard samples with confirmed Salmonella. Salmonella was confirmed by a reference laboratory in 29 samples either...

  18. A mega-analysis of memory reports from eight peer-reviewed false memory implantation studies.

    Science.gov (United States)

    Scoboria, Alan; Wade, Kimberley A; Lindsay, D Stephen; Azad, Tanjeem; Strange, Deryn; Ost, James; Hyman, Ira E

    2017-02-01

    Understanding that suggestive practices can promote false beliefs and false memories for childhood events is important in many settings (e.g., psychotherapeutic, medical, and legal). The generalisability of findings from memory implantation studies has been questioned due to variability in estimates across studies. Such variability is partly due to false memories having been operationalised differently across studies and to differences in memory induction techniques. We explored ways of defining false memory based on memory science and developed a reliable coding system that we applied to reports from eight published implantation studies (N = 423). Independent raters coded transcripts using seven criteria: accepting the suggestion, elaboration beyond the suggestion, imagery, coherence, emotion, memory statements, and not rejecting the suggestion. Using this scheme, 30.4% of cases were classified as false memories and another 23% were classified as having accepted the event to some degree. When the suggestion included self-relevant information, an imagination procedure, and was not accompanied by a photo depicting the event, the memory formation rate was 46.1%. Our research demonstrates a useful procedure for systematically combining data that are not amenable to meta-analysis, and provides the most valid estimate of false memory formation and associated moderating factors within the implantation literature to date.

  19. False memories in social anxiety disorder

    Directory of Open Access Journals (Sweden)

    PRISCILA DE CAMARGO PALMA

    Full Text Available Abstract Background False memories are memories of events that never occurred or that occurred, but not exactly as we recall. Events with emotional content are subject to false memories production similar to neutral events. However, individual differences, such as the level of maladjustment and emotional instability characteristics of Social Anxiety Disorder (SAD, may interfere in the production of false memories. Objectives This study aimed to assess the effect of emotion in memory performance for an event witnessed by participants with and without SAD. Methods Participants were 61 young adults with SAD and 76 without any symptoms of SAD who were randomly assigned to watch a story with or without emotional arousal. Participants answered a subjective scale of emotion about the story and a recognition memory test. Results Participants with SAD recovered more true memories and more false memories for the non-emotional version compared to the emotional version of the story. Overall, participants with SAD produced fewer false memories compared to those without SAD. Discussion This finding suggests that social anxiety may have a significant impact on emotional memory accuracy, which may assist in the development and improvement of techniques for therapeutic intervention.

  20. Attitude Importance and the False Consensus Effect.

    Science.gov (United States)

    Fabrigar, Leandre R.; Krosnick, Jon A.

    1995-01-01

    Explores the possibility that importance may regulate the magnitude of the false consensus effect. Analysis revealed a strong false consensus effect but no reliable relation between its magnitude and attitude importance. Results contradict assumptions that the false consensus effect arises from attitudes that directly or indirectly influence…

  1. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    Directory of Open Access Journals (Sweden)

    Tanatorn Tanantong

    2015-02-01

    Full Text Available False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs, the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  2. Current management of inguinal false aneurysms

    DEFF Research Database (Denmark)

    Houlind, Kim; Jepsen, Jørn M; Saicu, Cristian

    2017-01-01

    False aneurysms are formed as a result of bleeding causing a hematoma to compress the surrounding tissue. The majority of false aneurysms presenting to the vascular surgeon are caused by iatrogenic injury to an artery. Although anastomotic failure occurs, a much higher number is caused by bleeding...... vessels. endovascular treatment with coils or covered stent grafts have proven useful in infected ilio-femoral false aneurysms. Open surgical repair may be the best treatment in the setting of imminent rupture, massive haematoma and skin necrosis. We present three patient cases treated with open surgery...

  3. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  4. Tax Evasion in the Presence of Negative Income Tax Rates

    OpenAIRE

    Joulfaian, David; Rider, Mark

    1996-01-01

    Examines the impact of marginal tax rates, which incorporate the earned income tax credit as it existed in 1988, on the reporting of income by low-level taxpayers. Concludes that the amount of income underreported does not appear to be affected by the relatively high marginal tax rates which occur in the phase out range, except for proprietors.

  5. Approximation for the Finite-Time Ruin Probability of a General Risk Model with Constant Interest Rate and Extended Negatively Dependent Heavy-Tailed Claims

    Directory of Open Access Journals (Sweden)

    Yang Yang

    2011-01-01

    Full Text Available We propose a general continuous-time risk model with a constant interest rate. In this model, claims arrive according to an arbitrary counting process, while their sizes have dominantly varying tails and fulfill an extended negative dependence structure. We obtain an asymptotic formula for the finite-time ruin probability, which extends a corresponding result of Wang (2008.

  6. Increasing Shareholders Value through NPV-Negative Projects

    Directory of Open Access Journals (Sweden)

    Paweł Mielcarz

    2010-10-01

    of their higher expected rate of return. In the same circumstances, an undiversified shareholder may have a different perception of the investment. It is highly possible that he would be ready to accept a lower rate of return in exchange for more safety for his capital. The authors conclude that negative fundamental value (based on the market situation may be of importance for such shareholder as he prefers projects with lower risk and a lower rate of return. Temporary inefficiencies of the markets may produce a risk of bankruptcy or liquidity problems. The authors argue that NPV-negative projects may be a way to free additional cashflows, which will allow the financial restructuring of the company.  

  7. False vacuum decay in quantum mechanics and four dimensional scalar field theory

    Science.gov (United States)

    Bezuglov, Maxim

    2018-04-01

    When the Higgs boson was discovered in 2012 it was realized that electroweak vacuum may suffer a possible metastability on the Planck scale and can eventually decay. To understand this problem it is important to have reliable predictions for the vacuum decay rate within the framework of quantum field theory. For now, it can only be done at one loop level, which is apparently is not enough. The aim of this work is to develop a technique for the calculation of two and higher order radiative corrections to the false vacuum decay rate in the framework of four dimensional scalar quantum field theory and then apply it to the case of the Standard Model. To achieve this goal, we first start from the case of d=1 dimensional QFT i.e. quantum mechanics. We show that for some potentials two and three loop corrections can be very important and must be taken into account. Next, we use quantum mechanical example as a template for the general d=4 dimensional theory. In it we are concentrating on the calculations of bounce solution and corresponding Green function in so called thin wall approximation. The obtained Green function is then used as a main ingredient for the calculation of two loop radiative corrections to the false vacuum decay rate.

  8. Clinical characteristics of Helicobacter pylori-negative drug-negative peptic ulcer bleeding.

    Science.gov (United States)

    Chung, Woo Chul; Jeon, Eun Jung; Kim, Dae Bum; Sung, Hea Jung; Kim, Yeon-Ji; Lim, Eun Sun; Kim, Min-Ah; Oh, Jung Hwan

    2015-07-28

    To investigate the clinical characteristics and outcomes of idiopathic Helicobacter pylori (H. pylori)-negative and drug-negative] peptic ulcer bleeding (PUB). A consecutive series of patients who experienced PUB between 2006 and 2012 was retrospectively analyzed. A total of 232 patients were enrolled in this study. The patients were divided into four groups according to the etiologies of PUB: idiopathic, H. pylori-associated, drug-induced and combined (H. pylori-associated and drug-induced) types. We compared the clinical characteristics and outcomes between the groups. When the silver stain or rapid urease tests were H. pylori-negative, we obtained an additional biopsy specimen by endoscopic re-examination and performed an H. pylori antibody test 6-8 wk after the initial endoscopic examination. For a diagnosis of idiopathic PUB, a negative result of an H. pylori antibody test was confirmed. In all cases, re-bleeding was confirmed by endoscopic examination. For the risk assessment, the Blatchford and the Rockall scores were calculated for all patients. For PUB, the frequency of H. pylori infection was 59.5% (138/232), whereas the frequency of idiopathic cases was 8.6% (20/232). When idiopathic PUB was compared to H. pylori-associated PUB, the idiopathic PUB group showed a higher rate of re-bleeding after initial hemostasis during the hospital stay (30% vs 7.4%, P = 0.02). When idiopathic PUB was compared to drug-induced PUB, the patients in the idiopathic PUB group showed a higher rate of re-bleeding after initial hemostasis upon admission (30% vs 2.7%, P ulcer (77% vs 49%, P < 0.01). However, the Blatchford and the Rockall scores were not significantly different between the two groups. Among the patients who experienced drug-induced PUB, no significant differences were found with respect to clinical characteristics, irrespective of H. pylori infection. Idiopathic PUB has unique clinical characteristics such as re-bleeding after initial hemostasis upon admission

  9. Explaining the Development of False Memories.

    Science.gov (United States)

    Reyna, Valerie F.; Holliday, Robyn; Marche, Tammy

    2002-01-01

    Reviews explanatory dimensions of children's false memory relevant to forensic practice: measurement, development, social factors, individual differences, varieties of memories and memory judgments, and varieties of procedures inducing false memories. Asserts that recent studies fail to use techniques that separate acquiescence from memory…

  10. Elevated false recognition in patients with frontal lobe damage is neither a general nor a unitary phenomenon.

    Science.gov (United States)

    Verfaellie, Mieke; Rapcsak, Steven Z; Keane, Margaret M; Alexander, Michael P

    2004-01-01

    This study examined verbal recognition memory in amnesic patients with frontal lesions (AF), nonamnesic patients with frontal lesions (NAF), and amnesic patients with medial temporal lesions (MT). To examine susceptibility to false alarms, the number of studied words drawn from various categories was varied. The AF and MT groups demonstrated reduced hits and increased false alarms. False alarms were especially elevated when item-specific recollection was strongest in control participants. The NAF group performed indistinguishably from control participants, but several patients showed excessive false alarms in the context of normal hit rates. These patients exhibited impaired monitoring and verification processes. The findings demonstrate that elevated false recognition is not characteristic of all frontal patients and may result from more than 1 underlying mechanism. ((c) 2004 APA, all rights reserved)

  11. FACTOR STRUCTURE OF THE BRIEF NEGATIVE SYMPTOM SCALE

    OpenAIRE

    Strauss, Gregory P.; Hong, L. Elliot; Gold, James M.; Buchanan, Robert W.; McMahon, Robert P.; Keller, William R.; Fischer, Bernard A.; Catalano, Lauren T.; Culbreth, Adam J.; Carpenter, William T.; Kirkpatrick, Brian

    2012-01-01

    The current study examined the factor structure of the Brief Negative Symptom Scale (BNSS), a next-generation negative symptom rating instrument developed in response to the NIMH-sponsored Consensus Development Conference on Negative Symptoms. Participants included 146 individuals with a DSM-IV diagnosis of schizophrenia or schizoaffective disorder. Principal axis factoring indicated two distinct factors explaining 68.7% of the variance. Similar to previous findings, the factors reflected mot...

  12. Elucidating the neural correlates of related false memories using a systematic measure of perceptual relatedness.

    Science.gov (United States)

    Turney, Indira C; Dennis, Nancy A

    2017-02-01

    Previous memory research has exploited the perceptual similarities between lures and targets in order to evoke false memories. Nevertheless, while some studies have attempted to use lures that are objectively more similar than others, no study has systematically controlled for perceptual overlap between target and lure items and its role in accounting for false alarm rates or the neural processes underlying such perceptual false memories. The current study looked to fill this gap in the literature by using a face-morphing program to systematically control for the amount of perceptual overlap between lures and targets. Our results converge with previous studies in finding a pattern of differences between true and false memories. Most importantly, expanding upon this work, parametric analyses showed false memory activity increases with respect to the similarity between lures and targets within bilateral middle temporal gyri and right medial prefrontal cortex (mPFC). Moreover, this pattern of activation was unique to false memories and could not be accounted for by relatedness alone. Connectivity analyses further find that activity in the mPFC and left middle temporal gyrus co-vary, suggestive of gist-based monitoring within the context of false memories. Interestingly, neither the MTL nor the fusiform face area exhibited modulation as a function of target-lure relatedness. Overall, these results provide insight into the processes underlying false memories and further enhance our understanding of the role perceptual similarity plays in supporting false memories. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Inflation after False Vacuum Decay observational Prospects after Planck

    CERN Document Server

    Bousso, Raphael; Senatore, Leonardo

    2015-01-01

    We assess potential signals of the formation of our universe by the decay of a false vacuum. Negative spatial curvature is one possibility, but the window for its detection is now small. However, another possible signal is a suppression of the CMB power spectrum at large angles. This arises from the steepening of the effective potential as it interpolates between a flat inflationary plateau and the high barrier separating us from our parent vacuum. We demonstrate that these two effects can be parametrically separated in angular scale. Observationally, the steepening effect appears to be excluded at large l; but it remains consistent with the slight lack of power below l about 30 found by the WMAP and Planck collaborations. We give two simple models which improve the fit to the Planck data; one with observable curvature and one without. Despite cosmic variance, we argue that future CMB polarization and most importantly large-scale structure observations should be able to corroborate the Planck anomaly if it is...

  14. Mental Rotation in False Belief Understanding.

    Science.gov (United States)

    Xie, Jiushu; Cheung, Him; Shen, Manqiong; Wang, Ruiming

    2018-05-01

    This study examines the spontaneous use of embodied egocentric transformation (EET) in understanding false beliefs in the minds of others. EET involves the participants mentally transforming or rotating themselves into the orientation of an agent when trying to adopt his or her visuospatial perspective. We argue that psychological perspective taking such as false belief reasoning may also involve EET because of what has been widely reported in the embodied cognition literature, showing that our processing of abstract, propositional information is often grounded in concrete bodily sensations which are not apparently linked to higher cognition. In Experiment 1, an agent placed a ball into one of two boxes and left. The ball then rolled out and moved either into the other box (new box) or back into the original one (old box). The participants were to decide from which box they themselves or the agent would try to recover the ball. Results showed that false belief performance was affected by increased orientation disparity between the participants and the agent, suggesting involvement of embodied transformation. In Experiment 2, false belief was similarly induced and the participants were to decide if the agent would try to recover the ball in one specific box. Orientation disparity was again found to affect false belief performance. The present results extend previous findings on EET in visuospatial perspective taking and suggest that false belief reasoning, which is a kind of psychological perspective taking, can also involve embodied rotation, consistent with the embodied cognition view. Copyright © 2018 Cognitive Science Society, Inc.

  15. When representations conflict with reality: the preschooler's problem with false beliefs and "false" photographs.

    Science.gov (United States)

    Zaitchik, D

    1990-04-01

    It has been argued that young preschoolers cannot correctly attribute a false belief to a deceived actor (Wimmer & Perner, 1983). Some researchers claim that the problem lies in the child's inadequate epistemology (Chandler & Boyes, 1982; Wellman, 1988); as such, it is specific to the child's theory of mind and no such problem should appear in reasoning about nonmental representations. This prediction is tested below in the "false photograph" task: here an actor takes a photograph of an object in location X; the object is then moved to location Y. Preschool subjects are asked: "In the picture, where is the object?" Results indicate that photographs are no easier to reason about than are beliefs. Manipulations to boost performance on the photograph task proved ineffective. Further, an explanation of the failure as a processing limitation having nothing to do with the representational nature of beliefs or photographs was ruled out. It is argued that young children's failure on the false belief task is not due to an inadequate epistemology (though they may have one) and is symptomatic of a larger problem with representations.

  16. Dose-to-dose variations with single packages of counterfeit medicines and adulterated dietary supplements as a potential source of false negatives and inaccurate health risk assessments.

    Science.gov (United States)

    Venhuis, B J; Zwaagstra, M E; Keizers, P H J; de Kaste, D

    2014-02-01

    In this report, we show three examples of how the variability in dose units in single packages of counterfeit medicines and adulterated dietary supplements may contribute to a false negative screening result and inaccurate health risk assessments. We describe a counterfeit Viagra 100mg blister pack and a box of an instant coffee both containing dose units with and without an active pharmaceutical ingredient (API). We also describe a purportedly herbal slimming product with capsules that mutually differed in API and impurities. The adulterated dietary supplements contained sibutramine, benzyl-sibutramine, N-desmethyl-sibutramine (DMS), N,N-didesmethyl-sibutramine (DDMS) and several other related impurities. Counterfeit medicines and adulterated dietary supplements are a health risk because their quality is unreliable. Health risks are even greater when such unreliability extends to fundamental differences between dose units in one package. Because dose-to-dose variability for these products is unpredictable, the confidence interval of a sample size is unknown. Consequently, the analyses of a selection of dose units may not be representative for the package. In the worst case, counterfeit or unauthorised medicines are not recognised as such or a health risk is not identified. In order to reduce erroneous results particular care should be taken when analysing a composite of dose units, when finding no API in a dietary supplement and when finding conformity in a suspect counterfeit medicine. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Validation of a 4-item Negative Symptom Assessment (NSA-4): a short, practical clinical tool for the assessment of negative symptoms in schizophrenia.

    Science.gov (United States)

    Alphs, Larry; Morlock, Robert; Coon, Cheryl; Cazorla, Pilar; Szegedi, Armin; Panagides, John

    2011-06-01

    The 16-item Negative Symptom Assessment (NSA-16) scale is a validated tool for evaluating negative symptoms of schizophrenia. The psychometric properties and predictive power of a four-item version (NSA-4) were compared with the NSA-16. Baseline data from 561 patients with predominant negative symptoms of schizophrenia who participated in two identically designed clinical trials were evaluated. Ordered logistic regression analysis of ratings using NSA-4 and NSA-16 were compared with ratings using several other standard tools to determine predictive validity and construct validity. Internal consistency and test--retest reliability were also analyzed. NSA-16 and NSA-4 scores were both predictive of scores on the NSA global rating (odds ratio = 0.83-0.86) and the Clinical Global Impressions--Severity scale (odds ratio = 0.91-0.93). NSA-16 and NSA-4 showed high correlation with each other (Pearson r = 0.85), similar high correlation with other measures of negative symptoms (demonstrating convergent validity), and lesser correlations with measures of other forms of psychopathology (demonstrating divergent validity). NSA-16 and NSA-4 both showed acceptable internal consistency (Cronbach α, 0.85 and 0.64, respectively) and test--retest reliability (intraclass correlation coefficient, 0.87 and 0.82). This study demonstrates that NSA-4 offers accuracy comparable to the NSA-16 in rating negative symptoms in patients with schizophrenia. Copyright © 2011 John Wiley & Sons, Ltd.

  18. A national epidemiological study investigating risk factors for police interrogation and false confession among juveniles and young persons.

    Science.gov (United States)

    Gudjonsson, Gisli H; Sigurdsson, Jon Fridrik; Sigfusdottir, Inga Dora; Asgeirsdottir, Bryndis Bjork; González, Rafael A; Young, Susan

    2016-03-01

    The principal aims of this study are to identify risk factors associated with police arrest and false confessions and to investigate whether the severity of the ADHD condition/symptoms increases the risk. 22,226 young persons in Iceland anonymously completed self-report questionnaires screening for conduct disorder and ADHD. In addition, they stated whether they had a diagnosis of ADHD and had received ADHD medication, and their history of offending, police interrogation and false confession. Participants were stratified into two age groups, 14-16 and 17-24 years. The older group was significantly more likely to have been interrogated by the police but the younger group were much more vulnerable to false confession during interrogation. Males were more likely to be at risk for both than females. The severity of the ADHD condition increased the risk of both interrogation and false confession. Negative binomial regressions showed that age, gender, conduct disorder, offending, and ADHD symptoms were all significant predictors of both interrogations and number of false confessions. Conduct disorder was the single best predictor of police interrogation, but the findings were more mixed regarding false confessions. Young people presenting with a combination of severe ADHD and comorbid conduct disorder had the worst outcome for both interrogation and false confessions. The findings endorse the need for support of persons with ADHD to be put in place to ensure fair due process and to prevent miscarriages of justice.

  19. Remedies by competitors for false advertising.

    Science.gov (United States)

    Hirsch, B D; Wilcox, D P

    1990-05-01

    Patients who are victimized as a consequence of false medical advertising are not the only ones who can sue for damages. Under section 43(a) of the Lanham Act, effective November 17, 1989, anyone "who believes that he or she is or is likely to be damaged" by deceptive advertising may bring a civil action for damages (1). Competing physicians may sue other physicians who falsely advertise that they possess unique skills and achieve better results than other physicians because they employ exclusive methods of treatment or claim that certain surgical procedures they perform in the office are absolutely safe and without risk or who advertise false professional credentials to lure patients. Voluntary informed consent excludes the use of deceit. Misrepresentation through advertising deprives a patient of the right to exercise an informed consent (2). A patient who relies on a doctor's false advertising in agreeing to a procedure that causes the patient injury may sue for malpractice even if the procedure was performed without negligence. False medical advertising also exposes the advertiser to litigation by competitors for unfair competition. This article is concerned with the remedy that may be available for instituting private litigation against physicians and other health care providers who engage in untruthful advertising.

  20. The outcome of infected total knee arthroplasty: culture-positive versus culture-negative.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Kim, Dong-Jin

    2015-10-01

    We studied the outcome in culture-positive and culture-negative infected total knee arthroplasty (TKA). We retrospectively reviewed 140 patients with culture-positive and 102 patients with culture-negative infected TKAs. We determined the infection control rate and clinical outcome after repeated debridement, and repeated 2-stage TKA in the culture-positive and culture-negative groups. The mean follow-up was 9.3 years (range 5-14 years) in the culture-positive group and 10.6 years (5-22) in the culture-negative group. The overall infection control rate was 56 % in both groups after the first treatment. The overall infection control rate was 90 % in the culture-positive group and 95 % in the culture-negative group. A functional knee was obtained in 90 % in the culture-positive group and 95 % in the culture-negative group. The data suggest that treatment according to the types of infection in both culture-positive and culture-negative groups after TKA controlled infection and maintained functional TKA with a firm level of fixation for most patients. Repeated debridement and repeated two-stage exchange TKA further improved infection control rates after the initial treatment and increased the likelihood of maintaining a functional TKA.