WorldWideScience

Sample records for fall protection systems

  1. Fall Protection Introduction, #33462

    Energy Technology Data Exchange (ETDEWEB)

    Chochoms, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    The proper use of fall prevention and fall protection controls can reduce the risk of deaths and injuries caused by falls. This course, Fall Protection Introduction (#33462), is designed as an introduction to various types of recognized fall prevention and fall protection systems at Los Alamos National Laboratory (LANL), including guardrail systems, safety net systems, fall restraint systems, and fall arrest systems. Special emphasis is given to the components, inspection, care, and storage of personal fall arrest systems (PFASs). This course also presents controls for falling object hazards and emergency planning considerations for persons who have fallen.

  2. A Fall Protection System for High-Rise Construction

    Directory of Open Access Journals (Sweden)

    Haluk Çeçen

    2013-01-01

    Full Text Available In construction industry, the number of fatal and nonfatal occupational injuries is higher than other industries. Among causes of these accidents, “falls” play a key role. This situation reveals the importance for carrying out research in fall protection systems. In this paper, a practical, economical, and functional fall protection system is introduced. Following determination and evaluation of existing solutions, weekly brainstorming meetings were held among the responsible project staff (general coordinator, project coordinator, project manager, site manager, and health and safety manager. As a result of these meetings, design criteria were developed. Based on these criteria, the fall protection system for high-rise construction (FPSFHC was developed which satisfied all the specified design criteria. Required materials were procured from local dealers. In this paper, criteria used in design and details of the final design are presented. Field performance of the system is evaluated, and recommendations for further development and standardization of the system are added.

  3. Collective Fall Protection for Construction Workers

    Directory of Open Access Journals (Sweden)

    Sulowski, A. C.

    2014-03-01

    Full Text Available Construction safety regulations require protection of workers against falls from elevations. The collective fall protection systems, in most cases, allow workers to move freely without wearing individual fall protection gear. The collective systems which prevent falls are preferred over the fall arrest systems. The latter are employed only if prevention of falls is not feasible. Arresting a fall always carries with it a residual risk of injury to the fall victim. The collective fall arrest systems are employed primarily during construction of electricity or telecomm towers. The aim of this paper has been a review of the collective FPS employed in the construction industry.Las normas de seguridad en la construcción requieren de protección para los trabajadores contra las caídas desde altura. Los Sistemas de Protección contra Caídas (FPS, por sus siglas en inglés colectivos, en la mayoría de los casos, permiten que los trabajadores se muevan libremente sin usar un equipo de protección contra caídas individual. Los sistemas colectivos de prevención de caídas son preferibles a los sistemas de detención de caídas, estos últimos se emplean sólo si la prevención de las caídas no es factible. La detención de una caída siempre lleva consigo un riesgo residual de lesiones en la víctima accidentada. Los sistemas colectivos de detención de caídas se emplean principalmente en la construcción de torres de electricidad o telecomunicaciones. El objetivo de este trabajo ha sido la revisión de los sistemas colectivos de protección contra caídas empleados en la industria de la construcción.

  4. 29 CFR 1926.760 - Fall protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Fall protection. 1926.760 Section 1926.760 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.760 Fall protection. (a... protection from fall hazards in accordance with paragraph (a)(1) of this section. (c) Controlled Decking Zone...

  5. 78 FR 59725 - Construction Fall Protection Systems Criteria and Practices, and Training Requirements; Extension...

    Science.gov (United States)

    2013-09-27

    ...- 1648. Mail, hand delivery, express mail, messenger, or courier service: When using this method, you... DEPARTMENT OF LABOR Occupational Safety and Health Administration [Docket No. OSHA-2010-0008] Construction Fall Protection Systems Criteria and Practices, and Training Requirements; Extension of the Office...

  6. Fall protection training for rig workers : are your rig workers up to standard in fall risks and how to avoid them?

    Energy Technology Data Exchange (ETDEWEB)

    Chausse, C.

    2010-07-15

    This article offered advice on how to train rig workers in fall protection procedures. Any employee who works at height must complete fall protection training, which should be both in-classroom and hands-on, and site conditions must be closely simulated. There are three basic levels of training. A supervisor can identify hazards and has the authorization to take prompt corrective measures to ensure that all employees working at height are trained and using fall protection procedures. Any team leader should be trained as a competent person, who can conduct fall hazard surveys, identify new and existing fall hazards, and determine how to protect employees from each hazard. A qualified person is one who by certification or experience has successfully demonstrated an ability to resolve problems. The basic level of training ensures that a worker can recognize and control hazards, understand government fall regulations, follow post-fall rescue procedures, and select suitable rescue equipment. Supervisors may be trained as competent or qualified persons and should have knowledge of fall protection regulations, standards, and the equipment and systems being used in the workplace. Constant reminders at safety talks and refresher training are integral to maintaining a high degree of safety consciousness. 3 figs.

  7. 29 CFR Appendix C to Subpart M of... - Personal Fall Arrest Systems

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... fall distance should be supplied with the system, or in its absence, the least elastic lanyard or... considerations. (1) One of the most important aspects of personal fall protection systems is fully planning the...

  8. Practical example of the infrastructure protection against rock fall

    Science.gov (United States)

    Jirásko, Daniel; Vaníček, Ivan

    2017-09-01

    The protection of transport infrastructures against rock falls represents for the Czech Republic one of the sensitive questions. Rock falls, similarly as other typical geo-hazards for the Czech Republic, as landslides and floods, can have negative impact on safety and security of these infrastructures. One practical example how to reduce risk of rock fall is described in the paper. Great care is devoted to the visual inspection enabling to indicate places with high potential to failure. With the help of numerical modelling the range of rock fall negative impact is estimated. Protection measures are dealing with two basic ways. The first one utilize the results of numerical modelling for the optimal design of protection measures and the second one is focused on the monitoring of the rock blocks with high potential of instability together with wire-less transfer of measured results. After quick evaluation, e.g. comparison with warning values, some protection measures, mostly connected with closure of the potential sector, can be recommended.

  9. 29 CFR 1915.159 - Personal fall arrest systems (PFAS).

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Personal fall arrest systems (PFAS). 1915.159 Section 1915... Protective Equipment (PPE) § 1915.159 Personal fall arrest systems (PFAS). The criteria of this section apply to PFAS and their use. Effective January 1, 1998, body belts and non-locking snaphooks are not...

  10. Protect the Ones You Love From Falls

    Centers for Disease Control (CDC) Podcasts

    2008-12-10

    This podcast, developed as part of the Protect the Ones You Love initiative, discusses steps parents can take to help protect their children from falls, one of the leading causes of child injury.  Created: 12/10/2008 by National Center for Injury Prevention and Control (NCIPC).   Date Released: 12/10/2008.

  11. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2014

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-11-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2014. It was held on Nov.19-21, 2014 in Jeju, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2014. This proceedings is comprised of 8 sessions. The main topic titles of session are as follows: Radiation protection 1, Medical treatment and Biology 1, Radiation measurement 1, Radiation environment and protection 1, Radiation protection 2, Medical treatment and Biology 2, Radiation Measurement 2, Radiation environment and protection 2.

  12. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2013

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-11-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2013. It was held on Nov.20-22, 2013 Ramada Plaza Hotel in Suwon, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2013. This proceedings is comprised of 7 sessions. The main topic titles of session are as follows: Medical treatment and Biology 1, Measurement and Analysis 1, Radiation protection1, Medical treatment and Biology 2, Measurement and Analysis 2, Radiation protection 2, Radiation protection 3.

  13. Mechanical evaluation of hip pads to protect against fracture of elderly femurs in falls.

    Science.gov (United States)

    Tadano, Shigeru; Nakatsuchi, Hiroki; Goto, Naoko; Fujisaki, Kazuhiro; Nakatsuchi, Yukio

    2011-01-01

    Hip fracture in the aged easily occurs by falls and may cause these persons to become bedridden. Hip pads are effective in protecting hip fracture as they directly deflect and absorb the impact forces by falls. It is necessary for the material and the structure of hip pads to be designed to realize both high impact absorption and compliance (comfort during wearing). In this report, an impact testing system was developed to test the impact absorbing performance of hip pad with air cushions designed by the research group. The impact absorbing performance was evaluated by the impact load, collision time, and maximum load. To confirm the effectiveness in protecting against hip fracture, an impact force was applied to the greater trochanter of the human femur and the degree of fracture was measured by X-ray examination. As a result, the hip pad with air cushions had a high impact absorbing performance and was sufficiently effective to protect against hip fracture.

  14. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-11-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2011. It was held on Nov.17-18, 2011 the ocean resort in Yeosu, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2011. This proceedings is comprised of 14 sessions.

  15. Fall Protection Procedures for Sealing Bulk Waste Shipments by Rail Cars at Formerly Utilized Sites Remedial Action Program (FUSRAP) Sites - 13509

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J.D. [U.S. Army Corps of Engineers - Buffalo District, Buffalo, New York 14207 (United States); Fort, E. Joseph; Lorenz, William [Cabrera Services (Cabrera) East Harford, CT 06108 (United States); Mills, Andy [Shaw Environmental and Infrastructure, Inc. (Shaw) Baton Rouge, LA 70809 (United States)

    2013-07-01

    Rail-cars loaded with radioactive materials must be closed and fastened to comply with United States Department of Transportation (DOT) requirements before they shipped. Securing waste shipments in a manner that meets these regulations typically results in the use of a sealable rail-car liner. Workers accessing the tops of the 2.74 m high rail-cars to seal and inspect liners for compliance prior to shipment may be exposed to a fall hazard. Relatively recent revisions to the Fall Protection requirements in the Safety and Health Requirements Manual (EM385-1-1, U.S. Army Corps of Engineers) have necessitated modifications to the fall protection systems previously employed for rail-car loading at Formerly Utilized Sites Remedial Action Program (FUSRAP) sites. In response these projects have developed site-specific procedures to protect workers and maintain compliance with the improved fall protection regulations. (authors)

  16. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2016

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-12-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2016. It was held on Dec. 1, 2016 Phoenix Island in Jeju, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2016. This proceedings is comprised of 5 sessions. The main topic titles of session are as follows: Radiation protection, Biotechnology of radiation, Radiation measurement, Radiation environment and prevention, Radiation epidemiography.

  17. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2012

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-11-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2012. It was held on Nov. 28-30, 2012 Phoenix Island in Jeju, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2012. This proceedings is comprised of 8 sessions. The main topic titles of session are as follows: The main topic titles of session are as follows: Medical treatment and Biology 1, Measurement and Analysis 1, Measurement and Analysis 2, Radiation protection 1, Radiation protection 2, Medical treatment and Biology 2, Measurement and Analysis 3, Radiation protection 3.

  18. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2015

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-10-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2015. It was held on Oct.23, 2015 Mayfield Hotel in Seoul, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2015. This proceedings is comprised of 8 sessions. The main topic titles of session are as follows: Radiation protection 1, Medical treatment and Biology 1, Radiation Measurement 1, Radiation environment and disasters prevention 1, Radiation protection 2, Medical treatment and Biology 2, Radiation Measurement 2, Radiation environment and disasters prevention 2.

  19. Gamma radiation and gamma ray protection factors of ships in various situations of radioactive fall-out

    International Nuclear Information System (INIS)

    Brehm, E.H.; Holst, T.

    1975-01-01

    In this report the development of methods of evaluating gamma ray protection factors (GSF) of ships for various situations of radioactive fall-out is described. The joining calculations of gamma ray protection factors are performed by the newly developed computer procedure GASUFA. These protection factors determine - in connection with a measured gamma radiation dose at a given detector point - the gamma radiation in different compartments of the ships. The computer program GASUFA is able to perform calculations considering the dependence of energy, place and time for the following situations: - the ship is under a radioactive cloud without fall-out; - the ship is under a radioactive cloud with fall-out; - the ship is contaminated by radioactive fall-out; - the clean or decontaminated ship is going through a zone, which is contaminated by radioactive fall-out; - the ship and the surrounding water surface are contaminated by radioactive fall-out. (orig.) [de

  20. Drilling through Conservation Policy: Oil Exploration in Murchison Falls Protected Area, Uganda

    Directory of Open Access Journals (Sweden)

    Catrina A MacKenzie

    2017-01-01

    Full Text Available Approximately 2.5 billion barrels of commercially-viable oil, worth $2 billion in annual revenue for 20 years, were discovered under the Ugandan portion of the Albertine Rift in 2006. The region also contains seven of Uganda's protected areas and a growing ecotourism industry. We conducted interviews and focus groups in and around Murchison Falls Protected Area, Uganda's largest, oldest, and most visited protected area, to assess the interaction of oil exploration with the three primary conservation policies employed by Uganda Wildlife Authority: protectionism, neoliberal capital accumulation, and community-based conservation. We find that oil extraction is legally permitted inside protected areas in Uganda, like many other African countries, and that the wildlife authority and oil companies are adapting to co-exist inside a protected area. Our primary argument is that neoliberal capital accumulation as a conservation policy actually makes protected areas more vulnerable to industrial exploitation because nature is commodified, allowing economic value and profitability of land uses to determine how nature is exploited. Our secondary argument is that the conditional nature of protected area access inherent within the protectionist policy permits oil extraction within Murchison Falls Protected Area. Finally, we argue that community-based conservation, as operationalized in Uganda, has no role in defending protected areas against oil industrialisation.

  1. Protective and Catching Safety Systems In Construction

    Directory of Open Access Journals (Sweden)

    Kuzhin Marat

    2017-01-01

    Full Text Available In the article is described application of protective and catching systems in construction. Classification of similar systems, their types and purpose are listed. Dangerous zones on construction site and events to for limiting their influence or protection from the factors. Protective and catching systems is one of the most effective technical equipment, applied in recent time. Protective fences and catching systems are important part in the problem solution. Protective fences protect workers from falling from height. Protective and catching systems allows avoid injuries by workers, also catch debris, fallen from constructing buildings. In regard with continuing development in technical and technological solutions, protective and catching systems require adaptation to a new requirements of construction industry and requirements of normative documents. Technical regulations in the appliance sphere of protective and catching systems requires actualization and aligning with modern normatives. Important role should be given to developing organizational and technological documentation for application of the systems. Scientific studying of technical parameters of fences and protective catching nets also has great interest.

  2. 30 CFR 77.403 - Mobile equipment; falling object protective structures (FOPS).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mobile equipment; falling object protective structures (FOPS). 77.403 Section 77.403 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK...

  3. Analysis of NPP protection structure reliability under impact of a falling aircraft

    International Nuclear Information System (INIS)

    Shul'man, G.S.

    1996-01-01

    Methodology for evaluation of NPP protection structure reliability by impact of aircraft fall down is considered. The methodology is base on the probabilistic analysis of all potential events. The problem is solved in three stages: determination of loads on structural units, calculation of local reliability of protection structures by assigned loads and estimation of the structure reliability. The methodology proposed may be applied at the NPP design stage and by determination of reliability of already available structures

  4. Identifying protective and risk factors for injurious falls in patients hospitalized for acute care: a retrospective case-control study

    Directory of Open Access Journals (Sweden)

    Emmanuel Aryee

    2017-11-01

    Full Text Available Abstract Background Admitted patients who fall and injure themselves during an acute hospitalization incur increased costs, morbidity, and mortality, but little research has been conducted on identifying inpatients at high risk to injure themselves in a fall. Falls risk assessment tools have been unsuccessful due to their low positive predictive value when applied broadly to entire hospital populations. We aimed to identify variables associated with the risk of or protection against injurious fall in the inpatient setting. We also aimed to test the variables in the ABCs mnemonic (Age > 85, Bones-orthopedic conditions, anti-Coagulation and recent surgery for correlation with injurious fall. Methods We performed a retrospective case-control study at an academic tertiary care center comparing admitted patients with injurious fall to admitted patients without fall. We collected data on the demographics, medical and fall history, outcomes, and discharge disposition of injured fallers and control patients. We performed multivariate analysis of potential risk factors for injurious fall with logistic regression to calculate adjusted odds ratios. Results We identified 117 injured fallers and 320 controls. There were no differences in age, anti-coagulation use or fragility fractures between cases and controls. In multivariate analysis, recent surgery (OR 0.46, p = 0.003 was protective; joint replacement (OR 5.58, P = 0.002, psychotropic agents (OR 2.23, p = 0.001, the male sex (OR 2.08, p = 0.003 and history of fall (OR 2.08, p = 0.02 were significantly associated with injurious fall. Conclusion In this study, the variables in the ABCs parameters were among the variables not useful for identifying inpatients at risk of injuring themselves in a fall, while other non-ABCs variables demonstrated a significant association with injurious fall. Recent surgery was a protective factor, and practices around the care of surgical patients could be

  5. The Association Between Fall Frequency, Injury Risk, and Characteristics of Falls in Older Residents of Long-Term Care: Do Recurrent Fallers Fall More Safely?

    Science.gov (United States)

    van Schooten, Kimberley S; Yang, Yijian; Feldman, Fabio; Leung, Ming; McKay, Heather; Sims-Gould, Joanie; Robinovitch, Stephen N

    2018-05-09

    Although a fall is a necessary prerequisite to a fall-related injury, previous studies suggest that frequent fallers are at lower injury risk for a given fall. We tested the hypotheses that differences in protective responses or the circumstances of falls underlie differences in injury risk with fall frequency. We analyzed video footage of 897 falls experienced by 220 long-term care residents (mean age 82 ± 9 years) to identify the cause of imbalance, activity leading to falling, direction of fall initiation, balance recovery and fall protective responses, and occurrence of impact to the head or hip. We further obtained injury information from the facilities' fall registration. We used generalized estimating equation models to examine the association between quartiles of fall frequency, injury risk, and fall characteristics. Residents with the highest fall frequency group (Q4; ≥5.6 falls/year) were less likely to sustain an injury per fall. They were less likely to fall during walking and more likely to fall during stand-to-sit transfers. Residents in the lowest fall frequency group (Q1; falls/year) were more likely to fall during walking, and walking was associated with an increased risk for injury. When compared to less frequent fallers, more frequent fallers had a lower risk for injury per fall. This appeared to be explained by differences in the circumstances of falls, and not by protective responses. Injury prevention strategies in long-term care should target both frequent and infrequent fallers, as the latter are more mobile and apt to sustain injury.

  6. Comparison and Characterization of Android-Based Fall Detection Systems

    Directory of Open Access Journals (Sweden)

    Rafael Luque

    2014-10-01

    Full Text Available Falls are a foremost source of injuries and hospitalization for seniors. The adoption of automatic fall detection mechanisms can noticeably reduce the response time of the medical staff or caregivers when a fall takes place. Smartphones are being increasingly proposed as wearable, cost-effective and not-intrusive systems for fall detection. The exploitation of smartphones’ potential (and in particular, the Android Operating System can benefit from the wide implantation, the growing computational capabilities and the diversity of communication interfaces and embedded sensors of these personal devices. After revising the state-of-the-art on this matter, this study develops an experimental testbed to assess the performance of different fall detection algorithms that ground their decisions on the analysis of the inertial data registered by the accelerometer of the smartphone. Results obtained in a real testbed with diverse individuals indicate that the accuracy of the accelerometry-based techniques to identify the falls depends strongly on the fall pattern. The performed tests also show the difficulty to set detection acceleration thresholds that allow achieving a good trade-off between false negatives (falls that remain unnoticed and false positives (conventional movements that are erroneously classified as falls. In any case, the study of the evolution of the battery drain reveals that the extra power consumption introduced by the Android monitoring applications cannot be neglected when evaluating the autonomy and even the viability of fall detection systems.

  7. Comparison and characterization of Android-based fall detection systems.

    Science.gov (United States)

    Luque, Rafael; Casilari, Eduardo; Morón, María-José; Redondo, Gema

    2014-10-08

    Falls are a foremost source of injuries and hospitalization for seniors. The adoption of automatic fall detection mechanisms can noticeably reduce the response time of the medical staff or caregivers when a fall takes place. Smartphones are being increasingly proposed as wearable, cost-effective and not-intrusive systems for fall detection. The exploitation of smartphones' potential (and in particular, the Android Operating System) can benefit from the wide implantation, the growing computational capabilities and the diversity of communication interfaces and embedded sensors of these personal devices. After revising the state-of-the-art on this matter, this study develops an experimental testbed to assess the performance of different fall detection algorithms that ground their decisions on the analysis of the inertial data registered by the accelerometer of the smartphone. Results obtained in a real testbed with diverse individuals indicate that the accuracy of the accelerometry-based techniques to identify the falls depends strongly on the fall pattern. The performed tests also show the difficulty to set detection acceleration thresholds that allow achieving a good trade-off between false negatives (falls that remain unnoticed) and false positives (conventional movements that are erroneously classified as falls). In any case, the study of the evolution of the battery drain reveals that the extra power consumption introduced by the Android monitoring applications cannot be neglected when evaluating the autonomy and even the viability of fall detection systems.

  8. Comparison and Characterization of Android-Based Fall Detection Systems

    Science.gov (United States)

    Luque, Rafael; Casilari, Eduardo; Morón, María-José; Redondo, Gema

    2014-01-01

    Falls are a foremost source of injuries and hospitalization for seniors. The adoption of automatic fall detection mechanisms can noticeably reduce the response time of the medical staff or caregivers when a fall takes place. Smartphones are being increasingly proposed as wearable, cost-effective and not-intrusive systems for fall detection. The exploitation of smartphones' potential (and in particular, the Android Operating System) can benefit from the wide implantation, the growing computational capabilities and the diversity of communication interfaces and embedded sensors of these personal devices. After revising the state-of-the-art on this matter, this study develops an experimental testbed to assess the performance of different fall detection algorithms that ground their decisions on the analysis of the inertial data registered by the accelerometer of the smartphone. Results obtained in a real testbed with diverse individuals indicate that the accuracy of the accelerometry-based techniques to identify the falls depends strongly on the fall pattern. The performed tests also show the difficulty to set detection acceleration thresholds that allow achieving a good trade-off between false negatives (falls that remain unnoticed) and false positives (conventional movements that are erroneously classified as falls). In any case, the study of the evolution of the battery drain reveals that the extra power consumption introduced by the Android monitoring applications cannot be neglected when evaluating the autonomy and even the viability of fall detection systems. PMID:25299953

  9. Challenges, issues and trends in fall detection systems

    Science.gov (United States)

    2013-01-01

    Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a reference for both clinicians and biomedical engineers planning or conducting field investigations. Challenges, issues and trends in fall detection have been identified after the reviewing work. The number of studies using context-aware techniques is still increasing but there is a new trend towards the integration of fall detection into smartphones as well as the use of machine learning methods in the detection algorithm. We have also identified challenges regarding performance under real-life conditions, usability, and user acceptance as well as issues related to power consumption, real-time operations, sensing limitations, privacy and record of real-life falls. PMID:23829390

  10. Fall Prediction and Prevention Systems: Recent Trends, Challenges, and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Ramesh Rajagopalan

    2017-11-01

    Full Text Available Fall prediction is a multifaceted problem that involves complex interactions between physiological, behavioral, and environmental factors. Existing fall detection and prediction systems mainly focus on physiological factors such as gait, vision, and cognition, and do not address the multifactorial nature of falls. In addition, these systems lack efficient user interfaces and feedback for preventing future falls. Recent advances in internet of things (IoT and mobile technologies offer ample opportunities for integrating contextual information about patient behavior and environment along with physiological health data for predicting falls. This article reviews the state-of-the-art in fall detection and prediction systems. It also describes the challenges, limitations, and future directions in the design and implementation of effective fall prediction and prevention systems.

  11. Fall Prediction and Prevention Systems: Recent Trends, Challenges, and Future Research Directions.

    Science.gov (United States)

    Rajagopalan, Ramesh; Litvan, Irene; Jung, Tzyy-Ping

    2017-11-01

    Fall prediction is a multifaceted problem that involves complex interactions between physiological, behavioral, and environmental factors. Existing fall detection and prediction systems mainly focus on physiological factors such as gait, vision, and cognition, and do not address the multifactorial nature of falls. In addition, these systems lack efficient user interfaces and feedback for preventing future falls. Recent advances in internet of things (IoT) and mobile technologies offer ample opportunities for integrating contextual information about patient behavior and environment along with physiological health data for predicting falls. This article reviews the state-of-the-art in fall detection and prediction systems. It also describes the challenges, limitations, and future directions in the design and implementation of effective fall prediction and prevention systems.

  12. Blood Falls: A novel management approach for a subglacial feature of outstanding scientific importance

    Science.gov (United States)

    Carr, J. R.; Penhale, P. A.; Dahood, A.; Biletnikoff, N.; Harris, C. M.

    2012-04-01

    Blood Falls is a subglacial feature located in the ablation zone of the Taylor Glacier, Taylor Valley, McMurdo Dry Valleys, Antarctica. Blood Falls has a unique physical configuration, microbial ecology and geochemistry and consists of a subglacial brine reservoir and an iron-rich, saline surface discharge at the Taylor Glacier terminus. The feature provides a rare opportunity to sample properties of a subglacial reservoir and its ecosystem without the need for direct contact and is a key site for exobiological studies. The Blood Falls subglacial feature is globally unique and of outstanding scientific importance. As such, it warrants special protection from potential damage by drilling and/or surface activities. Moreover, currently subglacial environments are not represented in the Antarctic protected area network. To address these points, the United States National Science Foundation is working with the scientific community to develop at Blood Falls the first subglacial protected area in Antarctica. The protected area aims to maintain the integrity of the Blood Falls system, whilst allowing continued access for scientific and management purposes. Novel management approaches are being designed to protect the values of the site in three dimensions. Specific guidelines on activities conducted within the area, most notably drilling and coring, are being defined in a management plan. This new approach incorporates uncertainties in the location of the Blood Falls brine reservoir and the connectivity of the subglacial hydrological system of the Taylor Glacier. The management approaches employed at Blood Falls draw on the experience of the subglacial research community and potentially offer an effective framework for the protection of other subglacial environments.

  13. How Do Community-Dwelling Persons with Alzheimer Disease Fall Falls in the FINALEX Study

    Directory of Open Access Journals (Sweden)

    Niko M. Perttila

    2017-06-01

    Full Text Available Background: People with dementia are at high risk for falls. However, little is known of the features causing falls in Alzheimer disease (AD. Our aim was to investigate how participants with AD fall. Methods: In the FINALEX (Finnish Alzheimer Disease Exercise Trial study, participants’ (n = 194 falls were followed up for 1 year by diaries kept by their spouses. Results: The most common reason for falls (n = 355 was stumbling (n = 61. Of the falls, 123 led to injuries, 50 to emergency department visits, and 13 to fractures. The participants without falls (n = 103 were younger and had milder dementia than those with 1 (n = 34 or ≥2 falls (n = 57. Participants with a Mini Mental State Examination score of around 10 points were most prone to fall. In adjusted regression models, good nutritional status, good physical functioning, and use of antihypertensive medication (incident rate ratio [IRR] 0.68, 95% confidence interval [CI] 0.54–0.85 protected against falls, whereas fall history (IRR 2.71, 95% CI 2.13–3.44, osteoarthritis, diabetes mellitus, chronic obstructive pulmonary disease, higher number of drugs, drugs with anticholinergic properties, psychotropics, and opioids (IRR 4.27, 95% CI 2.92–6.24 were risk factors for falls. Conclusions: Our study provides a detailed account on how and why people with AD fall, suggesting several risk and protective factors.

  14. Development and evaluation of an automated fall risk assessment system.

    Science.gov (United States)

    Lee, Ju Young; Jin, Yinji; Piao, Jinshi; Lee, Sun-Mi

    2016-04-01

    Fall risk assessment is the first step toward prevention, and a risk assessment tool with high validity should be used. This study aimed to develop and validate an automated fall risk assessment system (Auto-FallRAS) to assess fall risks based on electronic medical records (EMRs) without additional data collected or entered by nurses. This study was conducted in a 1335-bed university hospital in Seoul, South Korea. The Auto-FallRAS was developed using 4211 fall-related clinical data extracted from EMRs. Participants included fall patients and non-fall patients (868 and 3472 for the development study; 752 and 3008 for the validation study; and 58 and 232 for validation after clinical application, respectively). The system was evaluated for predictive validity and concurrent validity. The final 10 predictors were included in the logistic regression model for the risk-scoring algorithm. The results of the Auto-FallRAS were shown as high/moderate/low risk on the EMR screen. The predictive validity analyzed after clinical application of the Auto-FallRAS was as follows: sensitivity = 0.95, NPV = 0.97 and Youden index = 0.44. The validity of the Morse Fall Scale assessed by nurses was as follows: sensitivity = 0.68, NPV = 0.88 and Youden index = 0.28. This study found that the Auto-FallRAS results were better than were the nurses' predictions. The advantage of the Auto-FallRAS is that it automatically analyzes information and shows patients' fall risk assessment results without requiring additional time from nurses. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  15. Design a Learning-Oriented Fall Event Reporting System Based on Kirkpatrick Model.

    Science.gov (United States)

    Zhou, Sicheng; Kang, Hong; Gong, Yang

    2017-01-01

    Patient fall has been a severe problem in healthcare facilities around the world due to its prevalence and cost. Routine fall prevention training programs are not as effective as expected. Using event reporting systems is the trend for reducing patient safety events such as falls, although some limitations of the systems exist at current stage. We summarized these limitations through literature review, and developed an improved web-based fall event reporting system. The Kirkpatrick model, widely used in the business area for training program evaluation, has been integrated during the design of our system. Different from traditional event reporting systems that only collect and store the reports, our system automatically annotates and analyzes the reported events, and provides users with timely knowledge support specific to the reported event. The paper illustrates the design of our system and how its features are intended to reduce patient falls by learning from previous errors.

  16. Fatal falls in the US construction industry, 1990 to 1999.

    Science.gov (United States)

    Derr, J; Forst, L; Chen, H Y; Conroy, L

    2001-10-01

    The Occupational Safety and Health Administration's (OSHA's) Integrated Management Information System (IMIS) database allows for the detailed analysis of risk factors surrounding fatal occupational events. This study used IMIS data to (1) perform a risk factor analysis of fatal construction falls, and (2) assess the impact of the February 1995 29 CFR Part 1926 Subpart M OSHA fall protection regulations for construction by calculating trends in fatal fall rates. In addition, IMIS data on fatal construction falls were compared with data from other occupational fatality surveillance systems. For falls in construction, the study identified several demographic factors that may indicate increased risk. A statistically significant downward trend in fatal falls was evident in all construction and within several construction categories during the decade. Although the study failed to show a statistically significant intervention effect from the new OSHA regulations, it may have lacked the power to do so.

  17. Geothermal District Heating System City of Klamath Falls

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, Paul J; Rafferty, Kevin

    1991-12-01

    The city of Klamath Falls became interested in the possibility of a establishing geothermal district heating system for downtown government buildings in January 1977. Since that time, the project has undergone some controversial and interesting developments that may be of educational value to other communities contemplating such a project. The purpose and content of this article is to identify the historical development of the project; including the design of the system, well owner objections to the project, aquifer testing, piping failure, and future expansion and marketing incentives. The shallow geothermal reservoir in Klamath falls extends for at least 6.8 miles in a northwest-southeast direction, as shown on Figure 1, with a width of about 2 miles. More than 550 thermal wells ranging in depth from about 10 to 2,000 ft, and obtaining or contacting water from 70 to 230oF, have been drilled into the reservoir. The system is not geologically homogeneous. Great variations in horizontal permeability and many vertical discontinuities exist because of stratigraphy and structure of the area. Basalt flows, eruptive centers, fluvial and lacustrine deposits, diatomite and pyroclastic materials alternate in the rock column. Normal faults with large throw (estimated up to 1,700 ft) are spaced less than 3,300 ft apart and appear to be the main avenue of vertical movement of hot fluids. In order to more effectively utilize this resource, the city of Klamath Falls decided in 1978 to apply for a federal grant (Program Opportunity Notice to cost share field experiment projects) to construct a geothermal district heating system that would deliver geothermal fluids to areas not located on the resource. In 1977, several Geo-Heat Center staff members visited Reykjavik, Iceland, to study the design of their geothermal district heating systems. This was in part the basis for the conceptual design and feasibility study (Lund, 1979) of a downtown commercial district. The main difference

  18. Effectiveness of an automatic manual wheelchair braking system in the prevention of falls.

    Science.gov (United States)

    Martorello, Laura; Swanson, Edward

    2006-01-01

    The purpose of this study was to evaluate the effectiveness of an automatic manual wheelchair braking system in the reduction of falls for patients at high risk of falls while transferring to and from a manual wheelchair. The study design was a normative survey carried out through the use of a written questionnaire sent to 60 skilled nursing facilities to collect data from the medical charts, which identified patients at high risk for falls who used an automatic wheelchair braking system. The facilities participating in the study identified a frequency of falls of high-risk patients while transferring to and from the wheelchair ranging from 2 to 10 per year, with a median fall rate per facility of 4 falls. One year after the installation of the automatic wheelchair braking system, participating facilities demonstrated a reduction of zero to three falls during transfers by high-risk patients, with a median fall rate of zero falls. This represents a statistically significant reduction of 78% in the fall rate of high-risk patients while transferring to and from the wheelchair, t (18) = 6.39, p braking system for manual wheelchairs was installed. The application of the automatic braking system allows clients, families/caregivers, and facility personnel an increased safety factor for the reduction of falls from the wheelchair.

  19. ICT-based system to predict and prevent falls (iStoppFalls): study protocol for an international multicenter randomized controlled trial

    OpenAIRE

    Gschwind, Yves J.; Eichberg, Sabine; Marston, Hannah R.; Ejupi, Andreas; De Rosario Martínez, Helios; Kroll, Michael; Drobics, Mario; Annegarn, Janneke; Wieching, Rainer; Lord, Stephen R.; Aal, Konstantin; Delbaere, Kim

    2014-01-01

    Background: Falls are very common, especially in adults aged 65 years and older. Within the current international European Commission's Seventh Framework Program (FP7) project 'iStoppFalls' an Information and Communication Technology (ICT) based system has been developed to regularly assess a person's risk of falling in their own home and to deliver an individual and tailored home-based exercise and education program for fall prevention. The primary aims of iStoppFalls are to assess the feasi...

  20. DEVELOPMENT OF WEARABLE HUMAN FALL DETECTION SYSTEM USING MULTILAYER PERCEPTRON NEURAL NETWORK

    Directory of Open Access Journals (Sweden)

    Hamideh Kerdegari

    2013-02-01

    Full Text Available This paper presents an accurate wearable fall detection system which can identify the occurrence of falls among elderly population. A waist worn tri-axial accelerometer was used to capture the movement signals of human body. A set of laboratory-based falls and activities of daily living (ADL were performed by volunteers with different physical characteristics. The collected acceleration patterns were classified precisely to fall and ADL using multilayer perceptron (MLP neural network. This work was resulted to a high accuracy wearable fall-detection system with the accuracy of 91.6%.

  1. Central nervous system medications and falls risk in men aged 60-75 years

    DEFF Research Database (Denmark)

    Masud, Tahir; Frost, Morten; Ryg, Jesper

    2013-01-01

    Introduction: drugs acting on the central nervous system (CNS) increase falls risk. Most data on CNS drugs and falls are in women/mixed-sex populations. This study assessed the relationship between CNS drugs and falls in men aged 60-75 years.......Introduction: drugs acting on the central nervous system (CNS) increase falls risk. Most data on CNS drugs and falls are in women/mixed-sex populations. This study assessed the relationship between CNS drugs and falls in men aged 60-75 years....

  2. Passive Cushiony Biomechanics of Head Protection in Falling Geckos

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2018-01-01

    Full Text Available Gekko geckos are capable to crawl on the steep even on upside-down surfaces. Such movement, especially at great altitude, puts them at high risks of incidentally dropping down and inevitable body or head impactions, though they may trigger air-righting reaction (ARR to attenuate the landing shocks. However, the air-righting ability (ARA in Gekko geckos is not fully developed. The implementation of ARR in some geckos is quite slow; and for those without tails, the ARR is even unobservable. Since ARA is compromised in Gekko geckos, there must be some other mechanisms responsible for protecting them from head injuries during falls. In this study, we looked into a Gekko gecko’s brain to study its internal environment and structure, using the magnetic resonance imaging (MRI technique. The results showed that the brain parenchyma was fully surrounded by the cerebrospinal fluid (CSF in the skull. A succulent characteristic was presented, which meant the intracalvarium was significantly occupied by the CSF, up to 45% in volume. Then a simplified three-dimensional finite element model was built, and a dynamic simulation was conducted to evaluate the mechanical property of this succulent characteristic during the head impactions. These implied the succulent characteristic may play certain roles on the self-protection in case of head impaction, which is adaptable to the Gekko gecko’s locomotion and behavior.

  3. ICT-based system to predict and prevent falls (iStoppFalls): study protocol for an international multicenter randomized controlled trial.

    Science.gov (United States)

    Gschwind, Yves J; Eichberg, Sabine; Marston, Hannah R; Ejupi, Andreas; Rosario, Helios de; Kroll, Michael; Drobics, Mario; Annegarn, Janneke; Wieching, Rainer; Lord, Stephen R; Aal, Konstantin; Delbaere, Kim

    2014-08-20

    Falls are very common, especially in adults aged 65 years and older. Within the current international European Commission's Seventh Framework Program (FP7) project 'iStoppFalls' an Information and Communication Technology (ICT) based system has been developed to regularly assess a person's risk of falling in their own home and to deliver an individual and tailored home-based exercise and education program for fall prevention. The primary aims of iStoppFalls are to assess the feasibility and acceptability of the intervention program, and its effectiveness to improve balance, muscle strength and quality of life in older people. This international, multicenter study is designed as a single-blinded, two-group randomized controlled trial. A total of 160 community-dwelling older people aged 65 years and older will be recruited in Germany (n = 60), Spain (n = 40), and Australia (n = 60) between November 2013 and May 2014. Participants in the intervention group will conduct a 16-week exercise program using the iStoppFalls system through their television set at home. Participants are encouraged to exercise for a total duration of 180 minutes per week. The training program consists of a variety of balance and strength exercises in the form of video games using exergame technology. Educational material about a healthy lifestyle will be provided to each participant. Final reassessments will be conducted after 16 weeks. The assessments include physical and cognitive tests as well as questionnaires assessing health, fear of falling, quality of life and psychosocial determinants. Falls will be followed up for six months by monthly falls calendars. We hypothesize that the regular use of this newly developed ICT-based system for fall prevention at home is feasible for older people. By using the iStoppFalls sensor-based exercise program, older people are expected to improve in balance and strength outcomes. In addition, the exercise training may have a positive impact on quality of

  4. Falling-incident detection and throughput enhancement in a multi-camera video-surveillance system.

    Science.gov (United States)

    Shieh, Wann-Yun; Huang, Ju-Chin

    2012-09-01

    For most elderly, unpredictable falling incidents may occur at the corner of stairs or a long corridor due to body frailty. If we delay to rescue a falling elder who is likely fainting, more serious consequent injury may occur. Traditional secure or video surveillance systems need caregivers to monitor a centralized screen continuously, or need an elder to wear sensors to detect falling incidents, which explicitly waste much human power or cause inconvenience for elders. In this paper, we propose an automatic falling-detection algorithm and implement this algorithm in a multi-camera video surveillance system. The algorithm uses each camera to fetch the images from the regions required to be monitored. It then uses a falling-pattern recognition algorithm to determine if a falling incident has occurred. If yes, system will send short messages to someone needs to be noticed. The algorithm has been implemented in a DSP-based hardware acceleration board for functionality proof. Simulation results show that the accuracy of falling detection can achieve at least 90% and the throughput of a four-camera surveillance system can be improved by about 2.1 times. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Body mass index, falls, and injurious falls among U.S. adults: Findings from the 2014 Behavioral Risk Factor Surveillance System.

    Science.gov (United States)

    Ylitalo, Kelly R; Karvonen-Gutierrez, Carrie A

    2016-10-01

    Falls are an important health concern because they are associated with loss of independence and disability, particularly among women. We determined the age- and sex-specific prevalence of injurious falls among adults in the United States and examined the impact of obesity on fall risk. Self-reported falls, injurious falls, and health histories were obtained from 280,035 adults aged 45-79years in the 2014 Behavioral Risk Factor Surveillance System. Body mass index was categorized as underweight (fall in the previous 12months. Mid-life women 55-59years reported the highest prevalence of injurious falls (15.4%). Among mid-life women, overweight was associated with injurious falls (RR=1.17; 95% CI: 1.08, 1.28), but overweight was not associated with falling among other age-sex groups. Class II/III obesity was associated with injurious falls among all age-sex groups. After considering the mediators like health conditions (depression, cardiovascular disease, diabetes, arthritis) and behaviors (physical activity, sleep), the association of class II/III obesity and injurious fall risk persisted only among mid-life women (RR=1.23; 95% CI: 1.12, 1.36). Not only are mid-life women at high risk for falls, but the class II/III obesity is a risk factor for injurious falls. Targeting mid-life women for fall and injury prevention is an important aim for practitioners, particularly given unique correlates of falling for this group. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Wireless Falling Detection System Based on Community.

    Science.gov (United States)

    Xia, Yun; Wu, Yanqi; Zhang, Bobo; Li, Zhiyang; He, Nongyue; Li, Song

    2015-06-01

    The elderly are more likely to suffer the aches or pains from the accidental falls, and both the physiology and psychology of patients would subject to a long-term disturbance, especially when the emergency treatment was not given timely and properly. Although many methods and devices have been developed creatively and shown their efficiency in experiments, few of them are suitable for commercial applications routinely. Here, we design a wearable falling detector as a mobile terminal, and utilize the wireless technology to transfer and monitor the activity data of the host in a relatively small community. With the help of the accelerometer sensor and the Google Mapping service, information of the location and the activity data will be send to the remote server for the downstream processing. The experimental result has shown that SA (Sum-vector of all axes) value of 2.5 g is the threshold value to distinguish the falling from other activities. A three-stage detection algorithm was adopted to increase the accuracy of the real alarm, and the accuracy rate of our system was more than 95%. With the further improvement, the falling detecting device which is low-cost, accurate and user-friendly would become more and more common in everyday life.

  7. Kinematic and behavioral analyses of protective stepping strategies and risk for falls among community living older adults.

    Science.gov (United States)

    Bair, Woei-Nan; Prettyman, Michelle G; Beamer, Brock A; Rogers, Mark W

    2016-07-01

    Protective stepping evoked by externally applied lateral perturbations reveals balance deficits underlying falls. However, a lack of comprehensive information about the control of different stepping strategies in relation to the magnitude of perturbation limits understanding of balance control in relation to age and fall status. The aim of this study was to investigate different protective stepping strategies and their kinematic and behavioral control characteristics in response to different magnitudes of lateral waist-pulls between older fallers and non-fallers. Fifty-two community-dwelling older adults (16 fallers) reacted naturally to maintain balance in response to five magnitudes of lateral waist-pulls. The balance tolerance limit (BTL, waist-pull magnitude where protective steps transitioned from single to multiple steps), first step control characteristics (stepping frequency and counts, spatial-temporal kinematic, and trunk position at landing) of four naturally selected protective step types were compared between fallers and non-fallers at- and above-BTL. Fallers took medial-steps most frequently while non-fallers most often took crossover-back-steps. Only non-fallers varied their step count and first step control parameters by step type at the instants of step initiation (onset time) and termination (trunk position), while both groups modulated step execution parameters (single stance duration and step length) by step type. Group differences were generally better demonstrated above-BTL. Fallers primarily used a biomechanically less effective medial-stepping strategy that may be partially explained by reduced somato-sensation. Fallers did not modulate their step parameters by step type at first step initiation and termination, instances particularly vulnerable to instability, reflecting their limitations in balance control during protective stepping. Copyright © 2016. Published by Elsevier Ltd.

  8. Numerical Estimation of Balanced and Falling States for Constrained Legged Systems

    Science.gov (United States)

    Mummolo, Carlotta; Mangialardi, Luigi; Kim, Joo H.

    2017-08-01

    Instability and risk of fall during standing and walking are common challenges for biped robots. While existing criteria from state-space dynamical systems approach or ground reference points are useful in some applications, complete system models and constraints have not been taken into account for prediction and indication of fall for general legged robots. In this study, a general numerical framework that estimates the balanced and falling states of legged systems is introduced. The overall approach is based on the integration of joint-space and Cartesian-space dynamics of a legged system model. The full-body constrained joint-space dynamics includes the contact forces and moments term due to current foot (or feet) support and another term due to altered contact configuration. According to the refined notions of balanced, falling, and fallen, the system parameters, physical constraints, and initial/final/boundary conditions for balancing are incorporated into constrained nonlinear optimization problems to solve for the velocity extrema (representing the maximum perturbation allowed to maintain balance without changing contacts) in the Cartesian space at each center-of-mass (COM) position within its workspace. The iterative algorithm constructs the stability boundary as a COM state-space partition between balanced and falling states. Inclusion in the resulting six-dimensional manifold is a necessary condition for a state of the given system to be balanced under the given contact configuration, while exclusion is a sufficient condition for falling. The framework is used to analyze the balance stability of example systems with various degrees of complexities. The manifold for a 1-degree-of-freedom (DOF) legged system is consistent with the experimental and simulation results in the existing studies for specific controller designs. The results for a 2-DOF system demonstrate the dependency of the COM state-space partition upon joint-space configuration (elbow-up vs

  9. Vision-based fall detection system for improving safety of elderly people

    KAUST Repository

    Harrou, Fouzi; Zerrouki, Nabil; Sun, Ying; Houacine, Amrane

    2017-01-01

    Recognition of human movements is very useful for several applications, such as smart rooms, interactive virtual reality systems, human detection and environment modeling. The objective of this work focuses on the detection and classification of falls based on variations in human silhouette shape, a key challenge in computer vision. Falls are a major health concern, specifically for the elderly. In this study, the detection is achieved with a multivariate exponentially weighted moving average (MEWMA) monitoring scheme, which is effective in detecting falls because it is sensitive to small changes. Unfortunately, an MEWMA statistic fails to differentiate real falls from some fall-like gestures. To remedy this limitation, a classification stage based on a support vector machine (SVM) is applied on detected sequences. To validate this methodology, two fall detection datasets have been tested: the University of Rzeszow fall detection dataset (URFD) and the fall detection dataset (FDD). The results of the MEWMA-based SVM are compared with three other classifiers: neural network (NN), naïve Bayes and K-nearest neighbor (KNN). These results show the capability of the developed strategy to distinguish fall events, suggesting that it can raise an early alert in the fall incidents.

  10. Vision-based fall detection system for improving safety of elderly people

    KAUST Repository

    Harrou, Fouzi

    2017-12-06

    Recognition of human movements is very useful for several applications, such as smart rooms, interactive virtual reality systems, human detection and environment modeling. The objective of this work focuses on the detection and classification of falls based on variations in human silhouette shape, a key challenge in computer vision. Falls are a major health concern, specifically for the elderly. In this study, the detection is achieved with a multivariate exponentially weighted moving average (MEWMA) monitoring scheme, which is effective in detecting falls because it is sensitive to small changes. Unfortunately, an MEWMA statistic fails to differentiate real falls from some fall-like gestures. To remedy this limitation, a classification stage based on a support vector machine (SVM) is applied on detected sequences. To validate this methodology, two fall detection datasets have been tested: the University of Rzeszow fall detection dataset (URFD) and the fall detection dataset (FDD). The results of the MEWMA-based SVM are compared with three other classifiers: neural network (NN), naïve Bayes and K-nearest neighbor (KNN). These results show the capability of the developed strategy to distinguish fall events, suggesting that it can raise an early alert in the fall incidents.

  11. A procedure for a mechanical evaluation of an undefined osteo-protective material.

    Science.gov (United States)

    Marques, Marco; Terroso, Miguel; Freitas, Ricardo; Marques, AntÓnio Torres; Gabriel, Joaquim; Simoes, Ricardo

    2015-02-01

    Falls represent a major care and cost problem to health and social services world-widely, since 50% of falls result in an injury. In this work, is proposed a methodology to evaluate protective pads materials and geometry performance, in order to reduce impact results in a fall event. Since the material properties and the pad geometry are the key factors to make the protection possible when a fall event occurs, our approach relies on the use of mechanical tests to evaluate the properties of the material and in the study of the pad response during a fall. For this, were used compression, tensile and instrumented falling weight tests, that allow a fully characterization of the materials that can be employed in the protective pads. Likewise, to gather precise information on falls events, in order to study the pad response during a fall, a set of laboratory fall trials were created using a camera-less inertial motion capture (mocap) system. This allow the acquisition of dynamic information of falls, namely acceleration and velocity that can be used to create a finite element analysis (FEA) model, where different segments from the human body can be evaluated when the protective pad is associated to it. Through the proposed methodology, different materials and pad geometries can be studied towards maximizing the performance of protection pads for falls. The mocap system allows the acquisition of fall data, and also the creation of a human body geometrical model, representative of the fall. From the mechanical trials, was showed that the spacer fabric embedded with silicone has the higher ability to reduce the peak force in case of impact when compared with all the other specimens. The compression and the tensile tests allow the mechanical definition of the material, and with this the material definition on the FEA model. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Don’t downplay ‘play’: Reasons why health systems should protect childhood play

    DEFF Research Database (Denmark)

    Nielsen, Lasse

    2018-01-01

    There has been much research on the importance of play for children’s development. However, questions of its political importance and our public institutions’ duties to protect it have been largely neglected. This article argues that childhood play is politically important due to both its intrinsic...... and instrumental value, and it suggests that the duty to protect the capability for play in childhood falls, at least partially, upon the public health system. If this argument holds, it follows that we have stronger duties towards our children than we currently believe....

  13. Impact of Fall Prevention on Nurses and Care of Fall Risk Patients.

    Science.gov (United States)

    King, Barbara; Pecanac, Kristen; Krupp, Anna; Liebzeit, Daniel; Mahoney, Jane

    2018-03-19

    Falls are common events for hospitalized older adults, resulting in negative outcomes both for patients and hospitals. The Center for Medicare and Medicaid (CMS) has placed pressure on hospital administrators by identifying falls as a "never event", resulting in a zero falls goal for many hospitals. Staff nurses are responsible for providing direct care to patients and for meeting the hospital no falls goal. Little is known about the impact of "zero falls" on nurses, patients and the organization. A qualitative study, using Grounded Dimensional Analysis (GDA) was conducted to explore nurses' experiences with fall prevention in hospital settings and the impact of those experiences on how nurses provide care to fall risk patients. Twenty-seven registered nurses and certified nursing assistants participated in in-depth interviews. Open, axial and selective coding was used to analyze data. A conceptual model which illustrates the impact of intense messaging from nursing administration to prevent patient falls on nurses, actions nurses take to address the message and the consequences to nurses, older adult patients and to the organization was developed. Intense messaging from hospital administration to achieve zero falls resulted in nurses developing a fear of falls, protecting self and unit, and restricting fall risk patients as a way to stop messages and meet the hospital goal. Results of this study identify unintended consequences of fall prevention message on nurses and older adult patients. Further research is needed understand how nurse care for fall risk patients.

  14. An Unobtrusive Fall Detection and Alerting System Based on Kalman Filter and Bayes Network Classifier.

    Science.gov (United States)

    He, Jian; Bai, Shuang; Wang, Xiaoyi

    2017-06-16

    Falls are one of the main health risks among the elderly. A fall detection system based on inertial sensors can automatically detect fall event and alert a caregiver for immediate assistance, so as to reduce injuries causing by falls. Nevertheless, most inertial sensor-based fall detection technologies have focused on the accuracy of detection while neglecting quantization noise caused by inertial sensor. In this paper, an activity model based on tri-axial acceleration and gyroscope is proposed, and the difference between activities of daily living (ADLs) and falls is analyzed. Meanwhile, a Kalman filter is proposed to preprocess the raw data so as to reduce noise. A sliding window and Bayes network classifier are introduced to develop a wearable fall detection system, which is composed of a wearable motion sensor and a smart phone. The experiment shows that the proposed system distinguishes simulated falls from ADLs with a high accuracy of 95.67%, while sensitivity and specificity are 99.0% and 95.0%, respectively. Furthermore, the smart phone can issue an alarm to caregivers so as to provide timely and accurate help for the elderly, as soon as the system detects a fall.

  15. Analysis of Public Datasets for Wearable Fall Detection Systems.

    Science.gov (United States)

    Casilari, Eduardo; Santoyo-Ramón, José-Antonio; Cano-García, José-Manuel

    2017-06-27

    Due to the boom of wireless handheld devices such as smartwatches and smartphones, wearable Fall Detection Systems (FDSs) have become a major focus of attention among the research community during the last years. The effectiveness of a wearable FDS must be contrasted against a wide variety of measurements obtained from inertial sensors during the occurrence of falls and Activities of Daily Living (ADLs). In this regard, the access to public databases constitutes the basis for an open and systematic assessment of fall detection techniques. This paper reviews and appraises twelve existing available data repositories containing measurements of ADLs and emulated falls envisaged for the evaluation of fall detection algorithms in wearable FDSs. The analysis of the found datasets is performed in a comprehensive way, taking into account the multiple factors involved in the definition of the testbeds deployed for the generation of the mobility samples. The study of the traces brings to light the lack of a common experimental benchmarking procedure and, consequently, the large heterogeneity of the datasets from a number of perspectives (length and number of samples, typology of the emulated falls and ADLs, characteristics of the test subjects, features and positions of the sensors, etc.). Concerning this, the statistical analysis of the samples reveals the impact of the sensor range on the reliability of the traces. In addition, the study evidences the importance of the selection of the ADLs and the need of categorizing the ADLs depending on the intensity of the movements in order to evaluate the capability of a certain detection algorithm to discriminate falls from ADLs.

  16. Machine protection systems

    CERN Document Server

    Macpherson, A L

    2010-01-01

    A summary of the Machine Protection System of the LHC is given, with particular attention given to the outstanding issues to be addressed, rather than the successes of the machine protection system from the 2009 run. In particular, the issues of Safe Machine Parameter system, collimation and beam cleaning, the beam dump system and abort gap cleaning, injection and dump protection, and the overall machine protection program for the upcoming run are summarised.

  17. iFall: an Android application for fall monitoring and response.

    Science.gov (United States)

    Sposaro, Frank; Tyson, Gary

    2009-01-01

    Injuries due to falls are among the leading causes of hospitalization in elderly persons, often resulting in a rapid decline in quality of life or death. Rapid response can improve the patients outcome, but this is often lacking when the injured person lives alone and the nature of the injury complicates calling for help. This paper presents an alert system for fall detection using common commercially available electronic devices to both detect the fall and alert authorities. We use an Android-based smart phone with an integrated tri-axial accelerometer. Data from the accelerometer is evaluated with several threshold based algorithms and position data to determine a fall. The threshold is adaptive based on user provided parameters such as: height, weight, and level of activity. The algorithm adapts to unique movements that a phone experiences as opposed to similar systems which require users to mount accelerometers to their chest or trunk. If a fall is suspected a notification is raised requiring the user's response. If the user does not respond, the system alerts pre-specified social contacts with an informational message via SMS. If a contact responds the system commits an audible notification, automatically connects, and enables the speakerphone. If a social contact confirms a fall, an appropriate emergency service is alerted. Our system provides a realizable, cost effective solution to fall detection using a simple graphical interface while not overwhelming the user with uncomfortable sensors.

  18. A Decision Support System for Preventing Falls in Elderly People

    Directory of Open Access Journals (Sweden)

    Estelle Courtial

    2015-12-01

    Full Text Available Preventing falls in older people is a real challenge for Public Health. This paper addresses this issue by designing a decision support system which provides a fall risk index. The proposed approach is based on three selected tests (the Timed up and go (TUG, the 30s sit-to-stand and the 4-stage balance tests, which are widely used in the medical sector for assessing mobility and balance of the elderly. During the tests, a video records the older person performing the test and thanks to an image processing algorithm, kinematics and biomechanics parameters are extracted. Based on fuzzy logic, a decision support system fuses all these data and estimates a fall risk index according to the senior's age and gender. It can also assist the Health Professional in making improved medical diagnosis relied on targeted measurements. Simulation results drawing on experimental data of 12 older persons performing the TUG test illustrate the feasibility and the effectiveness of the proposed approach. Objectively assessing the senior's motor functions and the fall risk is possible in less than 10 minutes, at low cost and in an easy and non invasive way.

  19. Analysis of Public Datasets for Wearable Fall Detection Systems

    Directory of Open Access Journals (Sweden)

    Eduardo Casilari

    2017-06-01

    Full Text Available Due to the boom of wireless handheld devices such as smartwatches and smartphones, wearable Fall Detection Systems (FDSs have become a major focus of attention among the research community during the last years. The effectiveness of a wearable FDS must be contrasted against a wide variety of measurements obtained from inertial sensors during the occurrence of falls and Activities of Daily Living (ADLs. In this regard, the access to public databases constitutes the basis for an open and systematic assessment of fall detection techniques. This paper reviews and appraises twelve existing available data repositories containing measurements of ADLs and emulated falls envisaged for the evaluation of fall detection algorithms in wearable FDSs. The analysis of the found datasets is performed in a comprehensive way, taking into account the multiple factors involved in the definition of the testbeds deployed for the generation of the mobility samples. The study of the traces brings to light the lack of a common experimental benchmarking procedure and, consequently, the large heterogeneity of the datasets from a number of perspectives (length and number of samples, typology of the emulated falls and ADLs, characteristics of the test subjects, features and positions of the sensors, etc.. Concerning this, the statistical analysis of the samples reveals the impact of the sensor range on the reliability of the traces. In addition, the study evidences the importance of the selection of the ADLs and the need of categorizing the ADLs depending on the intensity of the movements in order to evaluate the capability of a certain detection algorithm to discriminate falls from ADLs.

  20. Attracting predators without falling prey: chemical camouflage protects honeydew-producing treehoppers from ant predation.

    Science.gov (United States)

    Silveira, Henrique C P; Oliveira, Paulo S; Trigo, José R

    2010-02-01

    Predaceous ants are dominant organisms on foliage and represent a constant threat to herbivorous insects. The honeydew of sap-feeding hemipterans has been suggested to appease aggressive ants, which then begin tending activities. Here, we manipulated the cuticular chemical profiles of freeze-dried insect prey to show that chemical background matching with the host plant protects Guayaquila xiphias treehoppers against predaceous Camponotus crassus ants, regardless of honeydew supply. Ant predation is increased when treehoppers are transferred to a nonhost plant with which they have low chemical similarity. Palatable moth larvae manipulated to match the chemical background of Guayaquila's host plant attracted lower numbers of predatory ants than unchanged controls. Although aggressive tending ants can protect honeydew-producing hemipterans from natural enemies, they may prey on the trophobionts under shortage of alternative food resources. Thus chemical camouflage in G. xiphias allows the trophobiont to attract predaceous bodyguards at reduced risk of falling prey itself.

  1. Fall Protection Characteristics of Safety Belts and Human Impact Tolerance.

    Science.gov (United States)

    Hino, Yasumichi; Ohdo, Katsutoshi; Takahashi, Hiroki

    2014-08-23

    Many fatal accidents due to falls from heights have occurred at construction sites not only in Japan but also in other countries. This study aims to determine the fall prevention performance of two types of safety belts: a body belt 1) , which has been used for more than 40 yr in the Japanese construction industry as a general type of safety equipment for fall accident prevention, and a full harness 2, 3) , which has been used in many other countries. To determine human tolerance for impact trauma, this study discusses features of safety belts with reference 4-9) to relevant studies in the medical science, automobile crash safety, and aircrew safety. For this purpose, simple drop tests were carried out in a virtual workplace to measure impact load, head acceleration, and posture in the experiments, the Hybrid-III pedestrian model 10) was used as a human dummy. Hybrid-III is typically employed in official automobile crash tests (New Car Assessment Program: NCAP) and is currently recognized as a model that faithfully reproduces dynamic responses. Experimental results shows that safety performance strongly depends on both the variety of safety belts used and the shock absorbers attached onto lanyards. These findings indicate that fall prevention equipment, such as safety belts, lanyards, and shock absorbers, must be improved to reduce impact injuries to the human head and body during falls.

  2. Fatal falls and PFAS use in the construction industry: Findings from the NIOSH FACE reports.

    Science.gov (United States)

    Dong, Xiuwen Sue; Largay, Julie A; Choi, Sang D; Wang, Xuanwen; Cain, Chris Trahan; Romano, Nancy

    2017-05-01

    This study analyzed the Construction FACE Database (CFD), a quantitative database developed from reports of the Fatality Assessment and Control Evaluation (FACE) program conducted by the National Institute for Occupational Safety and Health (NIOSH). The CFD contains detailed data on 768 fatalities in the construction industry reported by NIOSH and individual states from 1982 through June 30, 2015. The results show that falls accounted for 42% (325) of the 768 fatalities included in the CFD. Personal fall arrest systems (PFAS) were not available to more than half of the fall decedents (54%); nearly one in four fall decedents (23%) had access to PFAS, but were not using it at the time of the fall. Lack of access to PFAS was particularly high among residential building contractors as well as roofing, siding, and sheet metal industry sectors (∼70%). Although the findings may not represent the entire construction industry today, they do provide strong evidence in favor of fall protection requirements by the Occupational Safety and Health Administration (OSHA). In addition to stronger enforcement, educating employers and workers about the importance and effectiveness of fall protection is crucial for compliance and fall prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Falling chains

    OpenAIRE

    Wong, Chun Wa; Yasui, Kosuke

    2005-01-01

    The one-dimensional fall of a folded chain with one end suspended from a rigid support and a chain falling from a resting heap on a table is studied. Because their Lagrangians contain no explicit time dependence, the falling chains are conservative systems. Their equations of motion are shown to contain a term that enforces energy conservation when masses are transferred between subchains. We show that Cayley's 1857 energy nonconserving solution for a chain falling from a resting heap is inco...

  4. ICT-based system to predict and prevent falls (iStoppFalls): results from an international multicenter randomized controlled trial.

    Science.gov (United States)

    Gschwind, Yves J; Eichberg, Sabine; Ejupi, Andreas; de Rosario, Helios; Kroll, Michael; Marston, Hannah R; Drobics, Mario; Annegarn, Janneke; Wieching, Rainer; Lord, Stephen R; Aal, Konstantin; Vaziri, Daryoush; Woodbury, Ashley; Fink, Dennis; Delbaere, Kim

    2015-01-01

    Falls and fall-related injuries are a serious public health issue. Exercise programs can effectively reduce fall risk in older people. The iStoppFalls project developed an Information and Communication Technology-based system to deliver an unsupervised exercise program in older people's homes. The primary aims of the iStoppFalls randomized controlled trial were to assess the feasibility (exercise adherence, acceptability and safety) of the intervention program and its effectiveness on common fall risk factors. A total of 153 community-dwelling people aged 65+ years took part in this international, multicentre, randomized controlled trial. Intervention group participants conducted the exercise program for 16 weeks, with a recommended duration of 120 min/week for balance exergames and 60 min/week for strength exercises. All intervention and control participants received educational material including advice on a healthy lifestyle and fall prevention. Assessments included physical and cognitive tests, and questionnaires for health, fear of falling, number of falls, quality of life and psychosocial outcomes. The median total exercise duration was 11.7 h (IQR = 22.0) over the 16-week intervention period. There were no adverse events. Physiological fall risk (Physiological Profile Assessment, PPA) reduced significantly more in the intervention group compared to the control group (F1,127 = 4.54, p = 0.035). There was a significant three-way interaction for fall risk assessed by the PPA between the high-adherence (>90 min/week; n = 18, 25.4 %), low-adherence (<90 min/week; n = 53, 74.6 %) and control group (F2,125 = 3.12, n = 75, p = 0.044). Post hoc analysis revealed a significantly larger effect in favour of the high-adherence group compared to the control group for fall risk (p = 0.031), postural sway (p = 0.046), stepping reaction time (p = 0.041), executive functioning (p = 0.044), and quality of life (p for

  5. Mitigating fall risk: A community fall reduction program.

    Science.gov (United States)

    Reinoso, Humberto; McCaffrey, Ruth G; Taylor, David W M

    One fourth of all American's over 65 years of age fall each year. Falls are a common and often devastating event that can pose a serious health risk for older adults. Healthcare providers are often unable to spend the time required to assist older adults with fall risk issues. Without a team approach to fall prevention the system remains focused on fragmented levels of health promotion and risk prevention. The specific aim of this project was to engage older adults from the community in a fall risk assessment program, using the Stopping Elderly Accidents, Deaths & Injuries (STEADI) program, and provide feedback on individual participants' risks that participants could share with their primary care physician. Older adults who attended the risk screening were taking medications that are known to increase falls. They mentioned that their health care providers do not screen for falls and appreciated a community based screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Proceedings of the KNS 2015 Fall Meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-10-15

    This proceedings contains articles of 2015 fall meeting of the Korean Nuclear Society. It was held on October 28-30 in Kyungju, Korea. This proceedings is comprised of 11 sessions. The main subject titles of session are as follows: Reactor system technology, Reactor physics and computational science, Radioactive waste management, Nuclear fuel and materials, Thermal hydraulics and safety, Radiation utilization and protection, Quantum engineering and nuclear fusion, Nuclear power plant construction and operation technology, Nuclear policy, human resources and cooperation, Nuclear I and C and automatic remote systems, Competition Session. (Yi, J. H.)

  7. Falls and fear of falling in vertigo and balance disorders: A controlled cross-sectional study.

    Science.gov (United States)

    Schlick, Cornelia; Schniepp, Roman; Loidl, Verena; Wuehr, Max; Hesselbarth, Kristin; Jahn, Klaus

    2016-01-01

    Vertigo and dizziness are among the most prevalent symptoms in neurologic disorders. Although many of these patients suffer from postural instability and gait disturbances, there is only limited data on their risk of falling. We conducted a controlled cross-sectional study at the tertiary care outpatient clinic of the German Center for Vertigo and Balance Disorders using a self-administered questionnaire to assess falls, fall-related injuries, and fear of falling. The recruitment period was 6 months. A total of 569 patients (mean age 59.6 ± 17.1 years, 55% females) and 100 healthy participants were included (response rate > 90%). Dizzy patients with central balance disorders (Parkinsonian, cerebellar, and brainstem oculomotor syndromes) had the highest fall rates (> 50% recurrent fallers, odds ratio > 10). The rate of recurrent fallers was 30% in bilateral vestibular failure and peripheral neuropathy (odds ratio > 5). Patients with functional dizziness (somatoform or phobic vertigo) were concerned about falling but did not fall more often than healthy controls (odds ratio 0.87). Falls are common in patients presenting to a dizziness unit. Those with central syndromes are at risk of recurrent and injurious falling. Fall rates and fear of falling should be assessed in balance disorders and used to guide the regimen of rehabilitation therapy. The identification of risk factors would help provide protective measures to these groups of patients.

  8. [Evaluation of postural control systems in elderly patients with repeated falls].

    Science.gov (United States)

    González Ramírez, Alfonso; Lázaro del Nogal, Montserrat; Ribera Casado, José Manuel

    2008-01-01

    a) to describe postural control disorders in elderly patients with recurrent falls; b) to analyze the influence of sensory deficits on centre of gravity control mechanisms; and c) to assess the functional consequences of balance disorders and falls in this group of patients. patients aged more than 65 years old referred to a falls unit with two or more falls in the previous 6 months were included in this study. The protocol included posturographic studies with a Neurocom Balance Master. To evaluate motor control, Rhythmic Weight Shift (RWS test) was performed. To assess sensorial control, Modified Clinical Test of Sensory Interaction on Balance (MCT test) was used. Other tests performed were the Sit to Stand (SS test), Walk across (WA test) and Step up over (SO test). a total of 109 patients (85.3% women) were studied. Mean age was 78.01 years (SD: 5.38). Disorders in one or more afferent sensorial systems were found in 51.7% of the patients (27.5% visual deficiencies, 17.6% vestibular alterations, and 6.6% somatosensorial deficits). Two afferent systems were compromised in 25.3%, and all three were compromised in 11.1% of the patients. No significant differences were found in directional control (RWS) when compared with the number of altered systems. posturographic studies provide sensitive information on static and dynamic centre of gravity control systems, eventual sensory deficits, and patients' ability to carry out basic activities of daily living. In our sample, the most frequent deficit was visual impairment. This information is essential to establish a correct management programme.

  9. Modeling Parkinson's disease falls associated with brainstem cholinergic systems decline.

    Science.gov (United States)

    Kucinski, Aaron; Sarter, Martin

    2015-04-01

    In addition to the primary disease-defining symptoms, approximately half of patients with Parkinson's disease (PD) suffer from postural instability, impairments in gait control and a propensity for falls. Consistent with evidence from patients, we previously demonstrated that combined striatal dopamine (DA) and basal forebrain (BF) cholinergic cell loss causes falls in rats traversing dynamic surfaces. Because evidence suggests that degeneration of brainstem cholinergic neurons arising from the pedunculopontine nucleus (PPN) also contributes to impaired gait and falls, here we assessed the effects of selective cholinergic PPN lesions in combination with striatal DA loss or BF cholinergic cells loss as well as losses in all 3 regions. Results indicate that all combination losses that included the BF cholinergic system slowed traversal and increased slips and falls. However, the performance of rats with losses in all 3 regions (PPN, BF, and DA) was not more severely impaired than following combined BF cholinergic and striatal DA lesions. These results confirm the hypothesis that BF cholinergic-striatal disruption of attentional-motor interactions is a primary source of falls. Additional losses of PPN cholinergic neurons may worsen posture and gait control in situations not captured by the current testing conditions. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  10. FPGA-Based Plant Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae [KEPCO E and C, Daejeon (Korea, Republic of)

    2011-08-15

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system.

  11. FPGA-Based Plant Protection System

    International Nuclear Information System (INIS)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae

    2011-01-01

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system

  12. Depth protection system

    International Nuclear Information System (INIS)

    Arita, Setsuo; Izumi, Shigeru; Suzuki, Satoru; Noguchi, Atomi.

    1988-01-01

    Purpose: To previously set a nuclear reactor toward safety side by the reactor scram if an emergency core cooling system is failed to operate. Constitution If abnormality occurs in an emergency core cooling system or an aqueous boric acid injection system, a reactor protection system is operated and, if the reactor protection system shows an abnormal state, a control rod withdrawal inhibition system is operated as a fundamental way. For instance, when the driving power source voltage for the emergency core cooling system is detected and, if it is lower than a predetermined value, the reactor protection system is operated. Alternatively, if the voltage goes lower than the predetermined value, the control rod withdrawal is inhibited. In addition, stopping for the feedwater system is inhibited. Further, integrity of the driving means for the emergency core cooling system is positively checked and the protection function is operated depending on the result of check. Since the nuclear reactor can be set toward the safety side even if the voltage for the driving power source of the aqueous boric acid injection system is lower than a predetermined value, the reactor safety can further be improved. (Horiuchi, T.)

  13. The circumstances, orientations, and impact locations of falls in community-dwelling older women.

    Science.gov (United States)

    Crenshaw, Jeremy R; Bernhardt, Kathie A; Achenbach, Sara J; Atkinson, Elizabeth J; Khosla, Sundeep; Kaufman, Kenton R; Amin, Shreyasee

    2017-11-01

    We sought to characterize the circumstances, orientations, and impact locations of falls in community-dwelling, ambulatory, older women. For this longitudinal, observational study, 125 community-dwelling women age≥65years were recruited. Over 12-months of follow-up, fall details were recorded using twice-monthly questionnaires. More than half (59%) of participants fell, with 30% of participants falling more than once (fall rate=1.3 falls per person-year). Slips (22%) and trips (33%) accounted for the majority of falls. Approximately 44% of falls were forward in direction, while backward falls accounted for 41% of falls. About a third of all falls were reported to have lateral (sideways) motion. Subjects reported taking a protective step in response to 82% of forward falls and 37% of backward falls. Of falls reporting lateral motion, a protective step was attempted in 70% of accounts. Common impact locations included the hip/pelvis (47% of falls) and the hand/wrist (27%). Backwards falls were most commonly reported with slips and when changing direction, and increased the risk of hip/pelvis impact (OR=12.6; 95% CI: 4.7-33.8). Forward falls were most commonly reported with trips and while hurrying, and increased the risk of impact to the hand/wrist (OR=2.6; 95% CI: 1.2-5.9). Falls in older ambulatory women occur more frequently than previously reported, with the fall circumstance and direction dictating impact to common fracture locations. Stepping was a common protective recovery strategy and that may serve as an appropriate focus of interventions to reduce falls in this high risk population. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. System level ESD protection

    CERN Document Server

    Vashchenko, Vladislav

    2014-01-01

    This book addresses key aspects of analog integrated circuits and systems design related to system level electrostatic discharge (ESD) protection.  It is an invaluable reference for anyone developing systems-on-chip (SoC) and systems-on-package (SoP), integrated with system-level ESD protection. The book focuses on both the design of semiconductor integrated circuit (IC) components with embedded, on-chip system level protection and IC-system co-design. The readers will be enabled to bring the system level ESD protection solutions to the level of integrated circuits, thereby reducing or completely eliminating the need for additional, discrete components on the printed circuit board (PCB) and meeting system-level ESD requirements. The authors take a systematic approach, based on IC-system ESD protection co-design. A detailed description of the available IC-level ESD testing methods is provided, together with a discussion of the correlation between IC-level and system-level ESD testing methods. The IC-level ESD...

  15. Proceedings of the KNS Fall meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-10-15

    This proceedings contains articles of 2013 Fall meeting of the Korean Nuclear Society. It was held on Oct 23-25 in Kyungju, Korea. This proceedings is comprised of 10 sessions. The main subject titles of session are as follows: Reactor system technology, Nuclear data, reactor physics and computational science, Radioactive waste management, Nuclear fuel and materials, Thermal hydraulics and safety, Radiation utilization and protection, Quantum engineering and nuclear fusion, Nuclear power plant construction and operation technology, Nuclear policy, human resources and cooperation, Nuclear I and C and remote operation. (Yi, J. H.)

  16. Falling chains as variable-mass systems: theoretical model and experimental analysis

    International Nuclear Information System (INIS)

    De Sousa, Célia A; Costa, Pedro; Gordo, Paulo M

    2012-01-01

    In this paper, we revisit, theoretically and experimentally, the fall of a folded U-chain and of a pile-chain. The model calculation implies the division of the whole system into two subsystems of variable mass, allowing us to explore the role of tensional contact forces at the boundary of the subsystems. This justifies, for instance, that the folded U-chain falls faster than the acceleration due to the gravitational force. This result, which matches quite well with the experimental data independently of the type of chain, implies that the falling chain is well described by energy conservation. We verify that these conclusions are not observed for the pile-chain motion. (paper)

  17. New Advances and Challenges of Fall Detection Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Tao Xu

    2018-03-01

    Full Text Available Falling, as one of the main harm threats to the elderly, has drawn researchers’ attentions and has always been one of the most valuable research topics in the daily health-care for the elderly in last two decades. Before 2014, several researchers reviewed the development of fall detection, presented issues and challenges, and navigated the direction for the study in the future. With smart sensors and Internet of Things (IoT developing rapidly, this field has made great progress. However, there is a lack of a review and discussion on novel sensors, technologies and algorithms introduced and employed from 2014, as well as the emerging challenges and new issues. To bridge this gap, we present an overview of fall detection research and discuss the core research questions on this topic. A total of 6830 related documents were collected and analyzed based on the key words. Among these documents, the twenty most influential and highly cited articles are selected and discussed profoundly from three perspectives: sensors, algorithms and performance. The findings would assist researchers in understanding current developments and barriers in the systems of fall detection. Although researchers achieve fruitful work and progress, this research domain still confronts challenges on theories and practice. In the near future, the new solutions based on advanced IoT will sustainably urge the development to prevent falling injuries.

  18. A piece of paper falling faster than free fall

    International Nuclear Information System (INIS)

    Vera, F; Rivera, R

    2011-01-01

    We report a simple experiment that clearly demonstrates a common error in the explanation of the classic experiment where a small piece of paper is put over a book and the system is let fall. This classic demonstration is used in introductory physics courses to show that after eliminating the friction force with the air, the piece of paper falls with acceleration g. To test if the paper falls behind the book in a nearly free fall motion or if it is dragged by the book, we designed a version of this experiment that includes a ball and a piece of paper over a book that is forced to fall using elastic cords. We recorded a video of our experiment using a high-speed video camera at 300 frames per second that shows that the book and the paper fall faster than the ball, which falls well behind the book with an acceleration approximately equal to g. Our experiment shows that the piece of paper is dragged behind the book and therefore the paper and book demonstration should not be used to show that all objects fall with acceleration g independently of their mass.

  19. A piece of paper falling faster than free fall

    Energy Technology Data Exchange (ETDEWEB)

    Vera, F; Rivera, R, E-mail: fvera@ucv.cl [Instituto de Fisica, Pontificia Universidad Catolica de ValparaIso, Av. Universidad 330, Curauma, ValparaIso (Chile)

    2011-09-15

    We report a simple experiment that clearly demonstrates a common error in the explanation of the classic experiment where a small piece of paper is put over a book and the system is let fall. This classic demonstration is used in introductory physics courses to show that after eliminating the friction force with the air, the piece of paper falls with acceleration g. To test if the paper falls behind the book in a nearly free fall motion or if it is dragged by the book, we designed a version of this experiment that includes a ball and a piece of paper over a book that is forced to fall using elastic cords. We recorded a video of our experiment using a high-speed video camera at 300 frames per second that shows that the book and the paper fall faster than the ball, which falls well behind the book with an acceleration approximately equal to g. Our experiment shows that the piece of paper is dragged behind the book and therefore the paper and book demonstration should not be used to show that all objects fall with acceleration g independently of their mass.

  20. Systems for protection and automation of distribution electric networks 22 kv

    International Nuclear Information System (INIS)

    Horak, M.

    2012-01-01

    This article deals with the new concept of fault location in overhead and cable 22 kV distribution systems, which are operated by ZSE Distribucia, a.s.. In the past the localisation of faults was a demanding and lengthy procedure, because the electric protection indicated only the affected output feeder. The exact fault point was then localised by manipulation in the field and by test switching in the power line where the fault took place. The current development of electric facilities and sharp fall in prices give use the possibility to broadly apply the simple digital metering devices equipped with the electric protection function. Once these devices are positioned densely along the individual power lines of the network, it is possible to localise the failure position quite exactly and electricity supply can be quickly restored. (Authors)

  1. Embedded DSP-based telehealth radar system for remote in-door fall detection.

    Science.gov (United States)

    Garripoli, Carmine; Mercuri, Marco; Karsmakers, Peter; Jack Soh, Ping; Crupi, Giovanni; Vandenbosch, Guy A E; Pace, Calogero; Leroux, Paul; Schreurs, Dominique

    2015-01-01

    Telehealth systems and applications are extensively investigated nowadays to enhance the quality-of-care and, in particular, to detect emergency situations and to monitor the well-being of elderly people, allowing them to stay at home independently as long as possible. In this paper, an embedded telehealth system for continuous, automatic, and remote monitoring of real-time fall emergencies is presented and discussed. The system, consisting of a radar sensor and base station, represents a cost-effective and efficient healthcare solution. The implementation of the fall detection data processing technique, based on the least-square support vector machines, through a digital signal processor and the management of the communication between radar sensor and base station are detailed. Experimental tests, for a total of 65 mimicked fall incidents, recorded with 16 human subjects (14 men and two women) that have been monitored for 320 min, have been used to validate the proposed system under real circumstances. The subjects' weight is between 55 and 90 kg with heights between 1.65 and 1.82 m, while their age is between 25 and 39 years. The experimental results have shown a sensitivity to detect the fall events in real time of 100% without reporting false positives. The tests have been performed in an area where the radar's operation was not limited by practical situations, namely, signal power, coverage of the antennas, and presence of obstacles between the subject and the antennas.

  2. Impact of Diabetic Complications on Balance and Falls: Contribution of the Vestibular System.

    Science.gov (United States)

    D'Silva, Linda J; Lin, James; Staecker, Hinrich; Whitney, Susan L; Kluding, Patricia M

    2016-03-01

    Diabetes causes many complications, including retinopathy and peripheral neuropathy, which are well understood as contributing to gait instability and falls. A less understood complication of diabetes is the effect on the vestibular system. The vestibular system contributes significantly to balance in static and dynamic conditions by providing spatially orienting information. It is noteworthy that diabetes has been reported to affect vestibular function in both animal and clinical studies. Pathophysiological changes in peripheral and central vestibular structures due to diabetes have been noted. Vestibular dysfunction is associated with impaired balance and a higher risk of falls. As the prevalence of diabetes increases, so does the potential for falls due to diabetic complications. The purpose of this perspective article is to present evidence on the pathophysiology of diabetes-related complications and their influence on balance and falls, with specific attention to emerging evidence of vestibular dysfunction due to diabetes. Understanding this relationship may be useful for screening (by physical therapists) for possible vestibular dysfunction in people with diabetes and for further developing and testing the efficacy of interventions to reduce falls in this population. © 2016 American Physical Therapy Association.

  3. Development of novel algorithm and real-time monitoring ambulatory system using Bluetooth module for fall detection in the elderly.

    Science.gov (United States)

    Hwang, J Y; Kang, J M; Jang, Y W; Kim, H

    2004-01-01

    Novel algorithm and real-time ambulatory monitoring system for fall detection in elderly people is described. Our system is comprised of accelerometer, tilt sensor and gyroscope. For real-time monitoring, we used Bluetooth. Accelerometer measures kinetic force, tilt sensor and gyroscope estimates body posture. Also, we suggested algorithm using signals which obtained from the system attached to the chest for fall detection. To evaluate our system and algorithm, we experimented on three people aged over 26 years. The experiment of four cases such as forward fall, backward fall, side fall and sit-stand was repeated ten times and the experiment in daily life activity was performed one time to each subject. These experiments showed that our system and algorithm could distinguish between falling and daily life activity. Moreover, the accuracy of fall detection is 96.7%. Our system is especially adapted for long-time and real-time ambulatory monitoring of elderly people in emergency situation.

  4. Power system protection

    International Nuclear Information System (INIS)

    Venkata, S.S.; Damborg, M.J.; Jampala, A.K.

    1991-01-01

    Power systems of the 21st century will be more modern, and complex, utilizing the latest available technologies. At the same time, generating plants will have to operate with minimal spinning margins and energy transportation has to take place at critical levels due to environmental and economical constraints. These factors dictate that the power systems be protected with optimum sensitivity, selectivity and time of operation to assure maximum reliability, and security at minimal cost. With an increasing role played by digital computers in every aspect of protection, it is important to take a critical and fresh look at the art and science of relaying and protection. The main objective of this paper is to review the past, present and future of power system protection from a software point of view

  5. Fall prevention walker during rehabilitation

    Science.gov (United States)

    Tee, Kian Sek; E, Chun Zhi; Saim, Hashim; Zakaria, Wan Nurshazwani Wan; Khialdin, Safinaz Binti Mohd; Isa, Hazlita; Awad, M. I.; Soon, Chin Fhong

    2017-09-01

    This paper proposes on the design of a walker for the prevention of falling among elderlies or patients during rehabilitation whenever they use a walker to assist them. Fall happens due to impaired balance or gait problem. The assistive device is designed by applying stability concept and an accelerometric fall detection system is included. The accelerometric fall detection system acts as an alerting device that acquires body accelerometric data and detect fall. Recorded accelerometric data could be useful for further assessment. Structural strength of the walker was verified via iterations of simulation using finite element analysis, before being fabricated. Experiments were conducted to identify the fall patterns using accelerometric data. The design process and detection of fall pattern demonstrates the design of a walker that could support the user without fail and alerts the helper, thus salvaging the users from injuries due to fall and unattended situation.

  6. Significant vestibular system impairment is common in a cohort of elderly patients referred for assessment of falls risk.

    Science.gov (United States)

    Jacobson, Gary P; McCaslin, Devin L; Grantham, Sarah L; Piker, Erin G

    2008-01-01

    Falls in elderly patients are associated with morbidity, mortality, and cost to the healthcare system. The development of falls risk assessment programs have represented a method of responding to what is known about injurious falls. The multidimensional assessments involve the comparison against normative data of a patient's performance on metrics known to influence the likelihood of future falls. The factors assessed usually include falls and medication history, measures of mentation, depression, orthostatic hypotension, simple or choice reaction time, gait stability, postural stability, and the integrity of the patient's vision, somesthetic, and vestibular senses. This investigation was conducted to measure the proportion of patients referred for falls risk assessment who have evidence of vestibular system impairment. Qualitative, retrospective review of data collected from 2003 to 2007. The cohort was 185 consecutive patients referred for multidimensional assessments of falls risk. Patients underwent quantitative assessments of peripheral and central vestibular system function consisting of electro- or videonystagmography (i.e., ENG/VNG), and sinusoidal harmonic acceleration testing. Results of these tests were compared to normative data. We found that 73% of the sample who underwent vestibular system assessment had quantitative evidence of either peripheral or central vestibular system impairment. Our results suggest that quantitative assessments of the vestibulo-ocular reflex should be conducted on patients who are evaluated for falls risk. These examinations should include at least caloric testing and, where available, rotational testing.

  7. Proceedings of the KNS 2014 Fall Meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-10-15

    This proceedings contains articles of 2014 Fall Meeting of the Korean Nuclear Society. It was held on Oct 29-31 in Pyongchang, Korea. This proceedings is comprised of 10 sessions. The main subject titles of session are as follows: Reactor system technology, Reactor physics and computational science, Radioactive waste management, Nuclear fuel and materials, Thermal hydraulics and safety, Radiation utilization and protection, Quantum engineering and nuclear fusion, Nuclear power plant construction and operation technology, Nuclear policy, human resources and cooperation, MMIS and remote control and Competition (Yi, J. H.)

  8. Buffer moisture protection system

    International Nuclear Information System (INIS)

    Ritola, J.; Peura, J.

    2013-11-01

    With the present knowledge, bentonite blocks have to be protected from the air relative humidity and from any moisture leakages in the environment that might cause swelling of the bentonite blocks during the 'open' installation phase before backfilling. The purpose of this work was to design the structural reference solution both for the bottom of the deposition hole and for the buffer moisture protection and dewatering system with their integrated equipment needed in the deposition hole. This report describes the Posiva's reference solution for the buffer moisture protection system and the bottom plate on basis of the demands and functional requirements set by long-term safety. The reference solution with structural details has been developed in research work made 2010-2011. The structural solution of the moisture protection system has not yet been tested in practice. On the bottom of the deposition hole a copper plate which protects the lowest bentonite block from the gathered water is installed straight to machined and even rock surface. The moisture protection sheet made of EPDM rubber is attached to the copper plate with an inflatable seal. The upper part of the moisture protection sheet is fixed to the collar structures of the lid which protects the deposition hole in the disposal tunnel. The main function of the moisture protection sheet is to protect bentonite blocks from the leaking water and from the influence of the air humidity at their installation stage. The leaking water is controlled by the dewatering and alarm system which has been integrated into the moisture protection liner. (orig.)

  9. Falls and outcomes amongst old people in rural dwellings | Adebiyi ...

    African Journals Online (AJOL)

    Being in a monogamous marriage and having normal sight were protective of having falls (OR 0.4, 95% CI 0.2 – 0.9; OR 0.4, 95% CI 0.2 – 0.9 respectively). Conclusion: Falls often occur from tripping and slipping while females are more likely to have major injuries. Risk factors for falls were alcohol use and diabetes while ...

  10. FIRE PROTECTION SYSTEMS AND TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Aristov Denis Ivanovich

    2016-03-01

    Full Text Available The All-Russian Congress “Fire Stop Moscow” was de-voted to the analysis of the four segments of the industry of fire protection systems and technologies: the design of fire protec-tion systems, the latest developments and technologies of active and passive fire protection of buildings, the state and the devel-opment of the legal framework, the practice of fire protection of buildings and structures. The forum brought together the repre-sentatives of the industry of fire protection systems, scientists, leading experts, specialists in fire protection and representatives of construction companies from different regions of Russia. In parallel with the Congress Industrial Exhibition of fire protection systems, materials and technology was held, where manufacturers presented their products. The urgency of the “Fire Stop Moscow” Congress in 2015 organized by the Congress Bureau ODF Events lies primarily in the fact that it considered the full range of issues related to the fire protection of building and construction projects; studied the state of the regulatory framework for fire safety and efficiency of public services, research centers, private companies and busi-nesses in the area of fire safety. The main practical significance of the event which was widely covered in the media space, was the opportunity to share the views and information between management, science, and practice of business on implementing fire protection systems in the conditions of modern economic relations and market realities. : congress, fire protection, systems, technologies, fire protection systems, exhibition

  11. Albeni Falls wildlife mitigation project: annual report of mitigation activities

    International Nuclear Information System (INIS)

    Terra-Burns, Mary

    2002-01-01

    The Albeni Falls Interagency Work Group was actively engaged in implementing wildlife mitigation activities in 2001. The Work Group met quarterly to discuss management and budget issues affecting the Albeni Falls Wildlife Mitigation Program. Work Group members protected 851 acres of wetland habitat in 2001. Wildlife habitat protected to date for the Albeni Falls project is approximately 5,248.31 acres (∼4,037.48 Habitat Units). Approximately 14% of the total wildlife habitat lost has been mitigated. Administrative activities increased as funding was more evenly distributed among Work Group members and protection opportunities became more time consuming. In 2001, Work Group members focused on development and implementation of the monitoring and evaluation program as well as completion of site-specific management plans. With the implementation of the monitoring and evaluation program, and as management plans are reviewed and executed, on the ground management activities are expected to increase in 2002

  12. Home Camera-Based Fall Detection System for the Elderly.

    Science.gov (United States)

    de Miguel, Koldo; Brunete, Alberto; Hernando, Miguel; Gambao, Ernesto

    2017-12-09

    Falls are the leading cause of injury and death in elderly individuals. Unfortunately, fall detectors are typically based on wearable devices, and the elderly often forget to wear them. In addition, fall detectors based on artificial vision are not yet available on the market. In this paper, we present a new low-cost fall detector for smart homes based on artificial vision algorithms. Our detector combines several algorithms (background subtraction, Kalman filtering and optical flow) as input to a machine learning algorithm with high detection accuracy. Tests conducted on over 50 different fall videos have shown a detection ratio of greater than 96%.

  13. Falls prevention for the elderly

    Directory of Open Access Journals (Sweden)

    Dagmar Lühmann

    2012-04-01

    inclusion criteria. However, to a variable degree the validity of their results must be rated as compromised due to different biasing factors. In summary, it appears that the performance of tests or the application of parameters to identify individuals at risk of falling yields little or no clinically relevant information. Positive effects of exercise interventions may be expected in relatively young and healthy seniors, while studies indicate opposite effects in the fragile elderly. For this specific vulnerable population the modification of the housing environment shows protective effects. A low number of studies, low quality of studies or inconsistent results lead to the conclusion that the effectiveness of the following interventions has to be rated unclear yet: correction of vision disorders, modification of psychotropic medication, vitamin D supplementation, nutritional supplements, psychological interventions, education of nursing personnel, multiple and multifactorial programs as well as the application of hip protectors. For the context of the German health care system the economic evaluations of fall prevention retrieved by the literature searches yield very few useful results. Cost-effectiveness calculations of fall prevention are mostly based on weak effectiveness data as well as on epidemiological and cost data from foreign health care systems. Ethical analysis demonstrates ambivalent views of the target population concerning fall risk and the necessity of fall prevention. The willingness to take up preventive measures depends on a variety of personal factors, the quality of information, guidance and decision-making, the prevention program itself and social support. The analysis of papers regarding legal issues shows three main challenges: the uncertainty of which standard of care has to be expected with regard to fall prevention, the necessity to consider the specific conditions of every single case when measures for fall prevention are applied, and the

  14. Masculinity and preventing falls: insights from the fall experiences of men aged 70 years and over.

    Science.gov (United States)

    Liddle, J L M; Lovarini, Meryl; Clemson, Lindy M; Jang, Haeyoung; Lord, Stephen R; Sherrington, Catherine; Willis, Karen

    2018-01-11

    To explore men's fall experiences through the lens of masculine identities so as to assist health professionals better engage men in fall prevention programs. Twenty-five men, aged 70-93 years who had experienced a recent fall, participated in a qualitative semi-structured interview. Men's willingness to engage in fall prevention programs taking account of individual contexts and expressions of masculinity, were conceptualised using constant comparative methods. Men's willingness to engage in fall prevention programs was related to their perceptions of the preventability of falls; personal relevance of falls; and age, health, and capability as well as problem-solving styles to prevent falls. Fall prevention advice was rarely given when men accessed the health system at the time of a fall. Contrary to dominant expectations about masculine identity, many men acknowledged fall vulnerability indicating they would attend or consider attending, a fall prevention program. Health professionals can better engage men by providing consistent messages that falls can be prevented; tailoring advice, understanding men are at different stages in their awareness of fall risk and preferences for action; and by being aware of their own assumptions that can act as barriers to speaking with men about fall prevention. Implications for rehabilitation Men accessing the health system at the time of the fall, and during rehabilitation following a fall represent prime opportunities for health professionals to speak with men about preventing falls and make appropriate referrals to community programs. Tailored advice will take account of individual men's perceptions of preventability; personal relevance; perceptions of age, health and capability; and problem-solving styles.

  15. Reactor protection system

    International Nuclear Information System (INIS)

    Fairbrother, D.B.; Lesniak, L.M.; Orgera, E.G.

    1977-10-01

    The report describes the reactor protection system (RPS-II) designed for use on Babcock and Wilcox 145-, later 177-, and 205-fuel assembly pressurized water reactors. In this system, relays in the trip logic have been replaced by solid state devices. A calculating module for the low DNBR, pump status, and offset trip functions has replaced the overpower trip (based on flow and imbalance), the power/RC pump trip, and the variable low-pressure trip. Included is a description of the changes from the present Oconee-type reactor protection system (RPS-I), a functional and hardware description of the calculating module, a description of the software programmed in the calculating module, and a discussion of the qualification program conducted to ensure that the degree of protection provided by RPS-II is not less than that provided by previously licensed systems supplied by B and W

  16. Home Camera-Based Fall Detection System for the Elderly

    Directory of Open Access Journals (Sweden)

    Koldo de Miguel

    2017-12-01

    Full Text Available Falls are the leading cause of injury and death in elderly individuals. Unfortunately, fall detectors are typically based on wearable devices, and the elderly often forget to wear them. In addition, fall detectors based on artificial vision are not yet available on the market. In this paper, we present a new low-cost fall detector for smart homes based on artificial vision algorithms. Our detector combines several algorithms (background subtraction, Kalman filtering and optical flow as input to a machine learning algorithm with high detection accuracy. Tests conducted on over 50 different fall videos have shown a detection ratio of greater than 96%.

  17. Systems approach to tamper protection

    International Nuclear Information System (INIS)

    Myre, W.C.; Eaton, M.J.

    1980-01-01

    Tamper-protection is a fundamental requirement of effective containment and surveillance systems. Cost effective designs require that the tamper protection requirements be considered early in the design phase and at the system level. A discussion of tamper protection alternatives as well as an illustrative example system is presented

  18. Involvement of older people in the development of fall detection systems: a scoping review.

    Science.gov (United States)

    Thilo, Friederike J S; Hürlimann, Barbara; Hahn, Sabine; Bilger, Selina; Schols, Jos M G A; Halfens, Ruud J G

    2016-02-11

    The involvement of users is recommended in the development of health related technologies, in order to address their needs and preferences and to improve the daily usage of these technologies. The objective of this literature review was to identify the nature and extent of research involving older people in the development of fall detection systems. A scoping review according to the framework of Arksey and O'Malley was carried out. A key term search was employed in eight relevant databases. Included articles were summarized using a predetermined charting form and subsequently thematically analysed. A total of 53 articles was included. In 49 of the 53 articles, older people were involved in the design and/or testing stages, and in 4 of 53 articles, they were involved in the conceptual or market deployment stages. In 38 of the 53 articles, the main focus of the involvement of older people was technical aspects. In 15 of the 53 articles, the perspectives of the elderly related to the fall detection system under development were determined using focus groups, single interviews or questionnaires. Until presently, involvement of older people in the development of fall detection systems has focused mainly on technical aspects. Little attention has been given to the specific needs and views of older people in the context of fall detection system development and usage.

  19. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  20. Heart rate response to a climber’s fall in sport climbing

    OpenAIRE

    Chaloupsky, David

    2015-01-01

    The research deals with response of heart rate to a climber’s simulated fall in a leading position when indoor climbing. Heart rate of climbers was recorded during ascents of an overhanging route in the leading position, to the given point high above the ground, followed by falling into the last protection. The length of the free fall was defined by the place of the last belay anchor, which was at the height of climber’s ankles. The length of the fall was about two meters of free fall plus th...

  1. SMART core protection system design

    International Nuclear Information System (INIS)

    Lee, J. K.; Park, H. Y.; Koo, I. S.; Park, H. S.; Kim, J. S.; Son, C. H.

    2003-01-01

    SMART COre Protection System(SCOPS) is designed with real-tims Digital Signal Processor(DSP) board and Network Interface Card(NIC) board. SCOPS has a Control Rod POSition (CRPOS) software module while Core Protection Calculator System(CPCS) consists of Core Protection Calculators(CPCs) and Control Element Assembly(CEA) Calculators(CEACs) in the commercial nuclear plant. It's not necessary to have a independent cabinets for SCOPS because SCOPS is physically very small. Then SCOPS is designed to share the cabinets with Plant Protection System(PPS) of SMART. Therefor it's very easy to maintain the system because CRPOS module is used instead of the computer with operating system

  2. Internship Progress Summary: Fall 2016

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ralph S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Valencia, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-13

    This fall I had the opportunity to work at Los Alamos National Laboratory for the Technology Applications engineering group. I assisted two main projects during my appointment, both related to the Lab’s mission statement: “To solve national security challenges through scientific excellence.” My first project, a thermal source transfer unit, involved skills such as mechanical design, heat transfer simulation, and design analysis. The goal was to create a container that could protect a heat source and regulate its temperature during transit. I generated several designs, performed heat transfer simulations, and chose a design for prototyping. The second project was a soil drying unit for use in post blast sample analysis. To ensure fast and accurate sample processing, agents in the field wanted a system that could process wet dirt and turn it into dry powder. We designed a system of commercially available parts, and we tested the systems to determine the best methods and processes.

  3. Evolution of the radiation protection system; L'evolution du systeme de protection radiologique

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, R.H. [International Commission on Radiological Protection, Stockholm (Sweden); Schieber, C.; Cordoliani, Y.S. [Societe Francaise de Radioprotection, 92 - Fontenay aux Roses (France); Brechignac, F. [CEA Cadarache, Institut de Radioprotection et de Surete Nucleaire, Dept. de Protection de l' Environnement, 13 - Saint Paul Lez Durance (France)

    2003-07-01

    The evolution of the system of radiological protection: justification for new ICRP recommendations, thoughts of the SFRP work group about the evolution of the system of radiation protection proposed by the ICRP, protection of environment against ionizing radiations seen by the ICRP are the three parts of this chapter. (N.C.)

  4. Digital integrated protection system

    International Nuclear Information System (INIS)

    Savornin, M.; Furet, M.

    1978-01-01

    As a result of technological progress it is now possible to achieve more elaborate protection functions able to follow more closely the phenomena to be supervised. For this reason the CEA, Framatome and Merlin/Gerin/CERCI have undertaken in commonn to develop a Digital Integrated Protection System (D.I.P.S.). This system is designed with the following aims: to improve the safety of the station, . to improve its availability, . to facilitate installation, . to facilitate tests and maintenance. The main characteristics adopted are: . possibilities of obtaining more elaborate monitoring and protection algorithm treatments, . order 4 redundancy of transducers, associated instruments and signal processing, . possibility of inhibiting part of the protection system, . standardisation of equipment, physical and electrical separation of redundant units, . use of multiplexed connections, . automation of tests. Four flow charts are presented: - DIPS with four APUP (Acquisition and Processing Unit for Protection) - APUP - LSU (Logic Safeguard Unit), number LSU corresponding to number fluidic safeguard circuits, - structure of a function unit, - main functions of the APUP [fr

  5. Real-time monitoring system for elderly people in detecting falling movement using accelerometer and gyroscope

    Science.gov (United States)

    Siregar, B.; Andayani, U.; Bahri, R. P.; Seniman; Fahmi, F.

    2018-03-01

    Most of the elderly people is experiencing a decrease in physical quality, especially the weakness in the legs. This will cause elderly easy to fall and can have a serious impact on their health if not getting help very quickly. It is, therefore, necessary to take immediate action against the falling cases experienced by the elderly. One such action is by developing supervision and detecting of falling movements in real-time, which is then the connection to a member of the family. In this research, we used Arduino Uno as a microcontroller, sensor accelerometer, and gyroscope that serves to measure falling movement of the elderly person and supported by GPS technology Ublox Neo 6M to provide information about coordinates. The result was the high accuracy of delivering notification data to server and accuracy of data delivery to family notification equal to 93,75%. The system successfully detects the direction of falling: forward, backward, left or right and able to distinguish between unintentional falling and conscious falling like a bow or prostrate position.

  6. Work-related falls among union carpenters in Washington State before and after the Vertical Fall Arrest Standard.

    Science.gov (United States)

    Lipscomb, Hester J; Li, Leiming; Dement, John

    2003-08-01

    Washington State enacted a change in their fall standard for the construction industry in 1991, preceding the Safety Standard for Fall Protection in the Construction Industry promulgated by Federal OSHA in 1994. We evaluated changes in the rate of falls from elevations and measures of severity among a large cohort of union carpenters after the fall standard change in Washington State, taking into account the temporal trends in their overall injury rates. There was a significant decrease in the rate of falls from height after the standard went into effect, even after adjusting for the overall decrease in work-related injuries among this cohort. Much of the decrease was immediate, likely representing the publicity surrounding fatal falls and subsequent promulgation of the standard. The greatest decrease was seen between 3 and 3(1/2) years after the standard went into effect. There was a significant reduction in mean paid lost days per event after the standard change and there was a significant reduction in mean cost per fall when adjusting for age and the temporal trend for costs among non-fall injuries. Through the use of observational methods we have demonstrated significant effects of the Washington State Vertical Fall Arrest Standard among carpenters in the absence of a control or comparison group. Without controlling for the temporal trend in overall injury rates, the rate of decline in falls appeared significantly greater, but the more pronounced, but delayed, decline was not seen. The analyses demonstrate potential error in failing to account for temporal patterns or assuming that a decline after an intervention is related to the intervention. Copyright 2003 Wiley-Liss, Inc.

  7. An expert system for the quantification of fault rates in construction fall accidents.

    Science.gov (United States)

    Talat Birgonul, M; Dikmen, Irem; Budayan, Cenk; Demirel, Tuncay

    2016-01-01

    Expert witness reports, prepared with the aim of quantifying fault rates among parties, play an important role in a court's final decision. However, conflicting fault rates assigned by different expert witness boards lead to iterative objections raised by the related parties. This unfavorable situation mainly originates due to the subjectivity of expert judgments and unavailability of objective information about the causes of accidents. As a solution to this shortcoming, an expert system based on a rule-based system was developed for the quantification of fault rates in construction fall accidents. The aim of developing DsSafe is decreasing the subjectivity inherent in expert witness reports. Eighty-four inspection reports prepared by the official and authorized inspectors were examined and root causes of construction fall accidents in Turkey were identified. Using this information, an evaluation form was designed and submitted to the experts. Experts were asked to evaluate the importance level of the factors that govern fall accidents and determine the fault rates under different scenarios. Based on expert judgments, a rule-based expert system was developed. The accuracy and reliability of DsSafe were tested with real data as obtained from finalized court cases. DsSafe gives satisfactory results.

  8. Seniors Falls Investigative Methodology (SFIM): A Systems Approach to the Study of Falls in Seniors

    Science.gov (United States)

    Zecevic, Aleksandra A.; Salmoni, Alan W.; Lewko, John H.; Vandervoort, Anthony A.

    2007-01-01

    An in-depth understanding of human factors and human error is lacking in current research on seniors' falls. Additional knowledge is needed to understand why seniors are falling. The purpose of this article is to describe the adapting of the Integrated Safety Investigation Methodology (ISIM) (used for investigating transportation and industrial…

  9. Effect of Remote Back-Up Protection System Failure on the Optimum Routine Test Time Interval of Power System Protection

    Directory of Open Access Journals (Sweden)

    Y Damchi

    2013-12-01

    Full Text Available Appropriate operation of protection system is one of the effective factors to have a desirable reliability in power systems, which vitally needs routine test of protection system. Precise determination of optimum routine test time interval (ORTTI plays a vital role in predicting the maintenance costs of protection system. In the most previous studies, ORTTI has been determined while remote back-up protection system was considered fully reliable. This assumption is not exactly correct since remote back-up protection system may operate incorrectly or fail to operate, the same as the primary protection system. Therefore, in order to determine the ORTTI, an extended Markov model is proposed in this paper considering failure probability for remote back-up protection system. In the proposed Markov model of the protection systems, monitoring facility is taken into account. Moreover, it is assumed that the primary and back-up protection systems are maintained simultaneously. Results show that the effect of remote back-up protection system failures on the reliability indices and optimum routine test intervals of protection system is considerable.

  10. Falling and fall risk factors in adults with haemophilia: an exploratory study.

    Science.gov (United States)

    Sammels, M; Vandesande, J; Vlaeyen, E; Peerlinck, K; Milisen, K

    2014-11-01

    Falls are a particular risk in persons with haemophilia (PWH) because of damaged joints, high risk of bleeding, possible impact on the musculoskeletal system and functioning and costs associated with treatment for these fall-related injuries. In addition, fall risk increases with age and PWH are increasingly entering the over 65 age group. The aim of this study was to determine the occurrence of falls during the past year and to explore which fall risk factors are present in community-dwelling PWH. Dutch speaking community-dwelling adults were included from the age of 40 years with severe or moderate haemophilia A or B, independent in their mobility and registered at the University Hospitals Leuven. They were asked to come to the haemophilia centre; otherwise a telephone survey was conducted. Demographic and social variables, medical variables, fall evaluation and clinical variables were queried. From the 89 PWH, 74 (83.1%) participated in the study. Twenty-four (32.4%) fell in the past year, and 10 of them (41.7%) more than once with an average of four falls. Living conditions, physical activity, avoidance of winter sports due to fear of falling, orthopaedic status, urinary incontinence and mobility impairments are potential fall risk factors in adult PWH. This exploratory study indicates that PWH are attentive to falling since they are at higher risk for falls and because of the serious consequences it might have. Screening and fall prevention should be stimulated in the daily practice of haemophilia care. © 2014 John Wiley & Sons Ltd.

  11. Geriatric falls in the context of a hospital fall prevention program: delirium, low body mass index, and other risk factors.

    Science.gov (United States)

    Mazur, Katarzyna; Wilczyński, Krzysztof; Szewieczek, Jan

    2016-01-01

    Inpatient geriatric falls are a frequent complication of hospital care that results in significant morbidity and mortality. Evaluate factors associated with falls in geriatric inpatients after implementation of the fall prevention program. Prospective observational study comprised of 788 consecutive patients aged 79.5±7.6 years ( [Formula: see text] ± standard deviation) (66% women and 34% men) admitted to the subacute geriatric ward. Comprehensive geriatric assessment (including Mini-Mental State Examination, Barthel Index of Activities of Daily Living, and modified Get-up and Go Test) was performed. Confusion Assessment Method was used for diagnosis of delirium. Patients were categorized into low, moderate, or high fall risk groups after clinical and functional assessment. About 15.9%, 21.1%, and 63.1% of participants were classified into low, moderate, and high fall risk groups, respectively. Twenty-seven falls were recorded in 26 patients. Increased fall probability was associated with age ≥76 years ( P fall risk were included in the multivariate logistic regression model: delirium (odds ratio [OR] =7.33; 95% confidence interval [95% CI] =2.76-19.49; P falls (OR =2.55; 95% CI =1.05-6.19; P =0.039), age (OR =1.14; 95% CI =1.05-1.23; P =0.001), and BMI (OR =0.91; 95% CI =0.83-0.99; P =0.034). Delirium, history of falls, and advanced age seem to be the primary risk factors for geriatric falls in the context of a hospital fall prevention program. Higher BMI appears to be associated with protection against inpatient geriatric falls.

  12. History of falls, gait, balance, and fall risks in older cancer survivors living in the community.

    Science.gov (United States)

    Huang, Min H; Shilling, Tracy; Miller, Kara A; Smith, Kristin; LaVictoire, Kayle

    2015-01-01

    Older cancer survivors may be predisposed to falls because cancer-related sequelae affect virtually all body systems. The use of a history of falls, gait speed, and balance tests to assess fall risks remains to be investigated in this population. This study examined the relationship of previous falls, gait, and balance with falls in community-dwelling older cancer survivors. At the baseline, demographics, health information, and the history of falls in the past year were obtained through interviewing. Participants performed tests including gait speed, Balance Evaluation Systems Test, and short-version of Activities-specific Balance Confidence scale. Falls were tracked by mailing of monthly reports for 6 months. A "faller" was a person with ≥1 fall during follow-up. Univariate analyses, including independent sample t-tests and Fisher's exact tests, compared baseline demographics, gait speed, and balance between fallers and non-fallers. For univariate analyses, Bonferroni correction was applied for multiple comparisons. Baseline variables with Pfalls with age as covariate. Sensitivity and specificity of each predictor of falls in the model were calculated. Significance level for the regression analysis was Pfalls. Baseline demographics, health information, history of falls, gaits speed, and balance tests did not differ significantly between fallers and non-fallers. Forward logistic regression revealed that a history of falls was a significant predictor of falls in the final model (odds ratio =6.81; 95% confidence interval =1.594-29.074) (Pfalls were 74% and 69%, respectively. Current findings suggested that for community-dwelling older cancer survivors with mixed diagnoses, asking about the history of falls may help detect individuals at risk of falling.

  13. Adaptive protection algorithm and system

    Science.gov (United States)

    Hedrick, Paul [Pittsburgh, PA; Toms, Helen L [Irwin, PA; Miller, Roger M [Mars, PA

    2009-04-28

    An adaptive protection algorithm and system for protecting electrical distribution systems traces the flow of power through a distribution system, assigns a value (or rank) to each circuit breaker in the system and then determines the appropriate trip set points based on the assigned rank.

  14. Epidemiology of falls in older age.

    Science.gov (United States)

    Peel, Nancye May

    2011-03-01

    Worldwide, falls among older people are a public health concern because of their frequency and adverse consequences in terms of morbidity, mortality, and quality of life, as well as their impact on health system services and costs. This epidemiological review outlines the public health burden of falls and fall-related injuries and the impact of population aging. The magnitude of the problem is described in terms of the classification of falls and measurement of outcomes, including fall incidence rates across settings, sociodemographic determinants, international trends, and costs of falls and fall-related injuries. Finally, public health approaches to minimize falls risk and consequent demand on health care resources are suggested.

  15. Advanced Worker Protection System

    International Nuclear Information System (INIS)

    1996-04-01

    The Advanced Worker Protection System (AWPS) is a liquid-air-based, self-contained breathing and cooling system with a duration of 2 hrs. AWPS employs a patented system developed by Oceaneering Space Systems (OSS), and was demonstrated at their facility in Houston, TX as well as at Kansas State University, Manhattan. The heart of the system is the life-support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack is combined with advanced protective garments, an advanced liquid cooling garment (LCG), a respirator, and communications and support equipment. The prototype unit development and testing under Phase 1 has demonstrated that AWPS has the ability to meet performance criteria. These criteria were developed with an understanding of both the AWPS capabilities and the DOE decontamination and decommissioning (D and D) activities protection needs

  16. The influence of headform orientation and flooring systems on impact dynamics during simulated fall-related head impacts.

    Science.gov (United States)

    Wright, Alexander D; Laing, Andrew C

    2012-10-01

    Novel compliant flooring systems are a promising approach for reducing fall-related injuries in seniors, as they may provide up to 50% attenuation in peak force during simulated hip impacts while eliciting only minimal influences on balance. This study aimed to determine the protective capacity of novel compliant floors during simulated 'high severity' head impacts compared to common flooring systems. A headform was impacted onto a common Commercial-Carpet at 1.5, 2.5, and 3.5 m/s in front, back, and side orientations using a mechanical drop tower. Peak impact force applied to the headform (F(max)), peak linear acceleration of the headform (g(max)) and Head Injury Criterion (HIC) were determined. For the 3.5 m/s trials, backwards-oriented impacts were associated with the highest F(max) and HIC values (pfloors (Resilient Rubber, Residential-Loop Carpet, Berber Carpet) and six novel compliant floors at each impact velocity. ANOVAs indicated that flooring type was associated with all parameters at each impact velocity (pfloors (pfloors can substantially reduce the forces and accelerations applied to a headform compared to common floors including carpet and resilient rubber. In combination with reports of minimal balance impairments, these findings support the promise of novel compliant floors as a biomechanically effective strategy for reducing fall-related injuries including traumatic brain injuries and skull fractures. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Protection of industrial power systems

    CERN Document Server

    DAVIES, T

    2006-01-01

    The protection which is installed on an industrial power system is likely to be subjected to more difficult conditions than the protection on any other kind of power system. Starting with the many simple devices which are employed and covering the whole area of industrial power system protection, this book aims to help achieve a thorough understanding of the protection necessary.Vital aspects such as the modern cartridge fuse, types of relays, and the role of the current transformer are covered and the widely used inverse definite-minimum time overcurrent relay, the theory of the M

  18. Albeni Falls Wildlife Mitigation : Annual Report 2002.

    Energy Technology Data Exchange (ETDEWEB)

    Terra-Berns, Mary

    2003-01-01

    The Albeni Falls Interagency Work Group continued to actively engage in implementing wildlife mitigation actions in 2002. Regular Work Group meetings were held to discuss budget concerns affecting the Albeni Falls Wildlife Mitigation Program, to present potential acquisition projects, and to discuss and evaluate other issues affecting the Work Group and Project. Work Group members protected 1,386.29 acres of wildlife habitat in 2002. To date, the Albeni Falls project has protected approximately 5,914.31 acres of wildlife habitat. About 21% of the total wildlife habitat lost has been mitigated. Administrative activities have increased as more properties are purchased and continue to center on restoration, operation and maintenance, and monitoring. In 2001, Work Group members focused on development of a monitoring and evaluation program as well as completion of site-specific management plans. This year the Work Group began implementation of the monitoring and evaluation program performing population and plant surveys, data evaluation and storage, and map development as well as developing management plans. Assuming that the current BPA budget restrictions will be lifted in the near future, the Work Group expects to increase mitigation properties this coming year with several potential projects.

  19. Retrieval-travel-time model for free-fall-flow-rack automated storage and retrieval system

    Science.gov (United States)

    Metahri, Dhiyaeddine; Hachemi, Khalid

    2018-03-01

    Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval-travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for drug distribution. This system is a new variation of flow-rack AS/RS that uses an operator or a single machine for storage operations, and uses a combination between the free-fall movement and a transport conveyor for retrieval operations. The main contribution of this paper is to develop an analytical model of the expected retrieval-travel time for the free-fall flow-rack under a dedicated storage assignment policy. The proposed model, which is based on a continuous approach, is compared for accuracy, via simulation, with discrete model. The obtained results show that the maximum deviation between the continuous model and the simulation is less than 5%, which shows the accuracy of our model to estimate the retrieval time. The analytical model is useful to optimise the dimensions of the rack, assess the system throughput, and evaluate different storage policies.

  20. Relay protection coordination with generator capability curve, excitation system limiters and power system relay protections settings

    Directory of Open Access Journals (Sweden)

    Buha Danilo

    2016-01-01

    Full Text Available The relay protection settings performed in the largest thermal powerplant (TE "Nikola Tesla B" are reffered and explained in this paper. The first calculation step is related to the coordination of the maximum stator current limiter settings, the overcurrent protection with inverse characteristics settings and the permitted overload of the generator stator B1. In the second calculation step the settings of impedance generator protection are determined, and the methods and criteria according to which the calculations are done are described. Criteria used to provide the protection to fulfill the backup protection role in the event of malfunction of the main protection of the transmission system. are clarified. The calculation of all protection functions (32 functions of generator B1 were performed in the project "Coordination of relay protection blocks B1 and B2 with the system of excitation and power system protections -TENT B".

  1. Using a laser measurement system for monitoring morphological changes on the Strug rock fall, Slovenia

    Directory of Open Access Journals (Sweden)

    M. Mikoš

    2005-01-01

    Full Text Available A medium-ranged high performance handheld reflectorless laser measurement system, was used for a morphological survey on the Strug rock fall in W Slovenia in the period from August 2003 to August 2004. The purpose was to evaluate its potential for monitoring ground surface changes in rock fall source areas and to help evaluating morphological changes by measuring distance from fixed points. In the area, 21 fixed geodetic points have been established. Altogether, seven measurement sets with more than 5500 points have been gathered in the rock fall area. Choosing a point cloud with a density of less than 1 point per 10m2 on a very rough rock fall surface failed to be a good solution. The changes on larger areas were shown by displacements of selected significantly large-sized rock blocks with a volume of several m3. Because only smaller changes were observed between the single field series, the rock fall surface generally remained unchanged. Local surface changes of the order of 1 m or more, were clearly shown by measurements in the selected referenced cross sections. The usage of these cross sections gave a possibility to evaluate volumetric changes on the surface. The laser measurement system provided a good replacement for the classical terrestrial geodetic survey equipment, especially when performing remote monitoring of morphological changes in rock fall hazard zones, however, the case is different when fixed points are to be measured precisely.

  2. Falls and Fall-Related Injuries among Community-Dwelling Adults in the United States.

    Directory of Open Access Journals (Sweden)

    Santosh K Verma

    Full Text Available Falls are the leading cause of unintentional injuries in the U.S.; however, national estimates for all community-dwelling adults are lacking. This study estimated the national incidence of falls and fall-related injuries among community-dwelling U.S. adults by age and gender and the trends in fall-related injuries across the adult life span.Nationally representative data from the National Health Interview Survey (NHIS 2008 Balance and Dizziness supplement was used to develop national estimates of falls, and pooled data from the NHIS was used to calculate estimates of fall-related injuries in the U.S. and related trends from 2004-2013. Costs of unintentional fall-related injuries were extracted from the CDC's Web-based Injury Statistics Query and Reporting System.Twelve percent of community-dwelling U.S. adults reported falling in the previous year for a total estimate of 80 million falls at a rate of 37.2 falls per 100 person-years. On average, 9.9 million fall-related injuries occurred each year with a rate of 4.38 fall-related injuries per 100 person-years. In the previous three months, 2.0% of older adults (65+, 1.1% of middle-aged adults (45-64 and 0.7% of young adults (18-44 reported a fall-related injury. Of all fall-related injuries among community-dwelling adults, 32.3% occurred among older adults, 35.3% among middle-aged adults and 32.3% among younger adults. The age-adjusted rate of fall-related injuries increased 4% per year among older women (95% CI 1%-7% from 2004 to 2013. Among U.S. adults, the total lifetime cost of annual unintentional fall-related injuries that resulted in a fatality, hospitalization or treatment in an emergency department was 111 billion U.S. dollars in 2010.Falls and fall-related injuries represent a significant health and safety problem for adults of all ages. The findings suggest that adult fall prevention efforts should consider the entire adult lifespan to ensure a greater public health benefit.

  3. Meteorite falls in Africa

    Science.gov (United States)

    Khiri, Fouad; Ibhi, Abderrahmane; Saint-Gerant, Thierry; Medjkane, Mohand; Ouknine, Lahcen

    2017-10-01

    The study of meteorites provides insight into the earliest history of our solar system. From 1800, about the year meteorites were first recognized as objects falling from the sky, until December 2014, 158 observed meteorite falls were recorded in Africa. Their collected mass ranges from 1.4 g to 175 kg with the 1-10 kg cases predominant. The average rate of African falls is low with only one fall recovery per 1.35-year time interval (or 0.023 per year per million km2). This African collection is dominated by ordinary chondrites (78%) just like in the worldwide falls. The seventeen achondrites include three Martian meteorite falls (Nakhla of Egypt, Tissint of Morocco and Zagami of Nigeria). Observed Iron meteorite falls are relatively rare and represent only 5%. The falls' rate in Africa is variable in time and in space. The number of falls continues to grow since 1860, 80% of which were recovered during the period between 1910 and 2014. Most of these documented meteorite falls have been recovered from North-Western Africa, Eastern Africa and Southern Africa. They are concentrated in countries which have a large surface area and a large population with a uniform distribution. Other factors are also favorable for observing and collecting meteorite falls across the African territory, such as: a genuine meteorite education, a semi-arid to arid climate (clear sky throughout the year most of the time), croplands or sparse grasslands and possible access to the fall location with a low percentage of forest cover and dense road network.

  4. A posture recognition based fall detection system for monitoring an elderly person in a smart home environment.

    Science.gov (United States)

    Yu, Miao; Rhuma, Adel; Naqvi, Syed Mohsen; Wang, Liang; Chambers, Jonathon

    2012-11-01

    We propose a novel computer vision based fall detection system for monitoring an elderly person in a home care application. Background subtraction is applied to extract the foreground human body and the result is improved by using certain post-processing. Information from ellipse fitting and a projection histogram along the axes of the ellipse are used as the features for distinguishing different postures of the human. These features are then fed into a directed acyclic graph support vector machine (DAGSVM) for posture classification, the result of which is then combined with derived floor information to detect a fall. From a dataset of 15 people, we show that our fall detection system can achieve a high fall detection rate (97.08%) and a very low false detection rate (0.8%) in a simulated home environment.

  5. Site observational work plan for the UMTRA project site at Falls City, Texas

    International Nuclear Information System (INIS)

    1994-09-01

    During surface remedial action, an estimated 7.0 million tons (6.4 million tonnes) of uranium mill tailings and other contaminated materials were consolidated and stabilized on the Falls City site. The ground water protection strategy at the Falls City disposal site for the UMTRA Surface Project (Subpart A of 40 CFR Part 192 (1994)) was an application for supplemental standards, based on Class III (limited use) ground water in the uppermost aquifer. This water is not a current or potential source of drinking water. Ground water from the uppermost aquifer (ground water from the Deweesville/Conquista Members and the Dilworth Member) contains widespread ambient contamination resulting from naturally occurring conditions and from the effects of human activity not related to uranium milling operations (uranium exploration and mining activities). The ground water cannot be effectively cleaned up for drinking or other beneficial purposes using treatment methods reasonably employed by public water supply systems. The U.S. Nuclear Regulatory Commission (NRC) and the state of Texas concurred with the ground water protection strategy for the disposal site in September 1992. Surface remedial action in accord with Subpart A was completed in April 1994. The proposed ground water compliance strategy (Subpart B of 40 CFR Part 192 (1994)) at the Falls City site is to perform no remedial action based on application for supplemental standards because the ground water in the uppermost aquifer is classified as Class III ground water. Class III ground water includes ground water that is not a current or potential source of drinking water because of widespread, ambient contamination that cannot be cleaned up using treatment methods reasonably employed by public water supply systems (40 CFR section 192.11 (e) (1994)). Although supplemental standards are being applied, the potential use of ground water in the site vicinity will be protected

  6. The rise and fall of an opt-out system.

    Science.gov (United States)

    Nordfalk, Francisca; Hoeyer, Klaus

    2018-04-01

    In Denmark, citizens participate in register-based research without the possibility of opting out. However, in 1995 it was made possible for Danish citizens to register an opt-out called 'researcher protection' [ forskerbeskyttelse], which implied that researchers could not contact people to invite them to participate in research projects, such as clinical trials or questionnaries, based on their registrations in national registers. Data already registered could still be used for research. In 2014, this possibility of opt-out was revoked by law. The aims of this paper are to understand how the Danish researcher protection system came about, why it was terminated and what we can we learn from this example. We conducted a descriptive analysis of a copy of the former researcher protection register along with policies and media debate surrounding the rise and revocation of the researcher protection system. Our results show how both the inception and the abolishment of researcher protection appear to be ad hoc and without specified criteria of success. An examination of the recorded entries in the researcher protection registry could have led to changes in its administration as an alternative to its total abolition. In future opt-out systems, there should be focus on monitoring register practices and the purpose and criteria for evaluation must be defined prior to implementation.

  7. Smart machine protection system

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.

    1992-01-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerators to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is complied into a logical decision tree for the 68030 processor. (author)

  8. Smart Machine Protection System

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.; Spencer, N.; Hutchinson, D.; Olsen, J.; Millsom, D.; White, G.; Gromme, T.; Allison, S.; Underwood, K.; Zelazny, M.; Kang, H.

    1991-11-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerator to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is compiled into a logical decision tree for the 68030 processor. 3 figs

  9. 77 FR 65380 - 2012 Fall Joint Meeting of the Ozone Transport Commission and the Mid-Atlantic Northeast...

    Science.gov (United States)

    2012-10-26

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9745-9] 2012 Fall Joint Meeting of the Ozone Transport Commission and the Mid-Atlantic Northeast Visibility Union AGENCY: Environmental Protection Agency (EPA... Fall Meeting of the Ozone Transport Commission (OTC) and the Mid-Atlantic Northeast Visibility Union...

  10. Behavioral thermoregulation by juvenile spring and fall chinook salmon, Oncorhynchus tshawytscha, during smoltification

    Science.gov (United States)

    Sauter, S.T.; Crawshaw, L.I.; Maule, A.G.

    2001-01-01

    Fall chinook salmon evolved to emigrate during the summer months. The shift in the temperature preference we observed in smolting fall chinook but not spring chinook salmon may reflect a phylogenetic adaptation to summer emigration by (1) providing directional orientation as fall chinook salmon move into the marine environment, (2) maintaining optimal gill function during emigration and seawater entry, and/or (3) resetting thermoregulatory set-points to support physiological homeostasis once smolted fish enter the marine environment. Phylogenetically determined temperature adaptations and responses to thermal stress may not protect fall chinook salmon from the recent higher summer water temperatures, altered annual thermal regimes, and degraded cold water refugia that result from hydropower regulation of the Columbia and Snake rivers. The long-term survival of fall chinook salmon will likely require restoration of normal annual thermographs and rigorous changes in land use practices to protect critical thermal refugia and control maximum summer water temperatures in reservoirs.

  11. Unsupervised machine-learning method for improving the performance of ambulatory fall-detection systems

    Directory of Open Access Journals (Sweden)

    Yuwono Mitchell

    2012-02-01

    Full Text Available Abstract Background Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environments, in part because impacts can be experienced as part of ordinary daily living activities. Method We used a waist-worn wireless tri-axial accelerometer combined with digital signal processing, clustering and neural network classifiers. The method includes the application of Discrete Wavelet Transform, Regrouping Particle Swarm Optimization, Gaussian Distribution of Clustered Knowledge and an ensemble of classifiers including a multilayer perceptron and Augmented Radial Basis Function (ARBF neural networks. Results Preliminary testing with 8 healthy individuals in a home environment yields 98.6% sensitivity to falls and 99.6% specificity for routine Activities of Daily Living (ADL data. Single ARB and MLP classifiers were compared with a combined classifier. The combined classifier offers the greatest sensitivity, with a slight reduction in specificity for routine ADL and an increased specificity for exercise activities. In preliminary tests, the approach achieves 100% sensitivity on in-group falls, 97.65% on out-group falls, 99.33% specificity on routine ADL, and 96.59% specificity on exercise ADL. Conclusion The pre-processing and feature-extraction steps appear to simplify the signal while successfully extracting the essential features that are required to characterize a fall. The results suggest this combination of classifiers can perform better than MLP alone. Preliminary testing suggests these methods may be useful for researchers who are attempting to improve the performance of ambulatory fall-detection systems.

  12. Automation warning system against driver falling asleep in-traffic

    Directory of Open Access Journals (Sweden)

    Dymov I. S.

    2017-12-01

    Full Text Available The paper is devoted to the development of a new automation recognition and warning system against driver falling asleep in-traffic. The issue of the physical condition control of professional drivers on the voyage has been considered both on the part of efficiency and quality of its determination, and in terms of improving overall road safety. The existing and widely used devices for determining the transition to the stage of sleep of drivers being in-traffic have been analyzed. Their advantages and disadvantages have been detected. It has been established that the main negative factor preventing the mass introduction of pre-existing warning systems is the need to wear one or another monitoring device before starting the movement. Carried out project research work has proposed a complex monitoring of the physical and physiological condition of driving person as a new warning method against falling asleep in-traffic. The proposed variations of algorithmic implementations can be used in long-distance trucks and passenger vehicles. Two different versions of the automatic control status of the driver physical condition have been considered. The first approach has proposed the use of sensors of the biometric parameters of body, pulsus, body temperature, and hands on wheel pressure sensors. The second one has proposed using the tracking cameras. Both for the first and second versions of the automation system a toolset of control devices is being installed inside the vehicle and have no physical, so irritating action on the driver. Software approach for the false operation rejection of the devices has been developed. The paper considers the flow diagrams of the automatic systems and logical structure of analysis and decision-making. The set of impacts intended for driver's awakening has been proposed. The conclusion about the engineering perspectives of the proposed approach of projected automation systems has been made.

  13. 76 FR 59125 - 2011 Fall Meeting of the Ozone Transport Commission

    Science.gov (United States)

    2011-09-23

    ..., Washington, DC 20001; (202) 508-3840; e-mail: [email protected] ; Web site: http://www.otcair.org...) 508-3840; by e-mail: [email protected] or via the OTC Web site at http://www.otcair.org . Dated... ENVIRONMENTAL PROTECTION AGENCY [FRL-9470-8] 2011 Fall Meeting of the Ozone Transport Commission...

  14. 75 FR 58378 - 2010 Fall Meeting of the Ozone Transport Commission

    Science.gov (United States)

    2010-09-24

    ..., Washington, DC 20001; (202) 508-3840; e-mail: [email protected] ; Web site: http://www.otcair.org...) 508-3840; by e-mail: [email protected] or via the OTC Web site at http://www.otcair.org . Dated... ENVIRONMENTAL PROTECTION AGENCY [FRL-9206-6] 2010 Fall Meeting of the Ozone Transport Commission...

  15. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system

  16. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system. 8 refs

  17. Falls and Fall-Related Injuries among Community-Dwelling Adults in the United States

    Science.gov (United States)

    Verma, Santosh K.; Willetts, Joanna L.; Corns, Helen L.; Marucci-Wellman, Helen R.; Lombardi, David A.; Courtney, Theodore K.

    2016-01-01

    Introduction Falls are the leading cause of unintentional injuries in the U.S.; however, national estimates for all community-dwelling adults are lacking. This study estimated the national incidence of falls and fall-related injuries among community-dwelling U.S. adults by age and gender and the trends in fall-related injuries across the adult life span. Methods Nationally representative data from the National Health Interview Survey (NHIS) 2008 Balance and Dizziness supplement was used to develop national estimates of falls, and pooled data from the NHIS was used to calculate estimates of fall-related injuries in the U.S. and related trends from 2004–2013. Costs of unintentional fall-related injuries were extracted from the CDC’s Web-based Injury Statistics Query and Reporting System. Results Twelve percent of community-dwelling U.S. adults reported falling in the previous year for a total estimate of 80 million falls at a rate of 37.2 falls per 100 person-years. On average, 9.9 million fall-related injuries occurred each year with a rate of 4.38 fall-related injuries per 100 person-years. In the previous three months, 2.0% of older adults (65+), 1.1% of middle-aged adults (45–64) and 0.7% of young adults (18–44) reported a fall-related injury. Of all fall-related injuries among community-dwelling adults, 32.3% occurred among older adults, 35.3% among middle-aged adults and 32.3% among younger adults. The age-adjusted rate of fall-related injuries increased 4% per year among older women (95% CI 1%–7%) from 2004 to 2013. Among U.S. adults, the total lifetime cost of annual unintentional fall-related injuries that resulted in a fatality, hospitalization or treatment in an emergency department was 111 billion U.S. dollars in 2010. Conclusions Falls and fall-related injuries represent a significant health and safety problem for adults of all ages. The findings suggest that adult fall prevention efforts should consider the entire adult lifespan to ensure a

  18. Selectivity of power system protections at power swings in power system

    Directory of Open Access Journals (Sweden)

    Jan Machowski

    2012-12-01

    Full Text Available The paper discusses out-of-step protection systems such as: generator pole slip protections, out of step tripping protections, distance protections of step-up transformer, distance protections of transmission lines and transformers, power swing blocking, and special out-of-step protection. It is shown that all these protections make up a protection system, to which a setting concept uniform for the entire power system has to be applied. If a power system is inappropriately equipped with these protections, or their settings are inappropriate, they may operate unselectively, thus contributing to the development of power system blackouts. In the paper the concepts for a real power system are given for the two stages: target stage fully compliant with selectivity criteria, and transitional stage between the current and target stages.

  19. Reactor protection and shut-down system

    International Nuclear Information System (INIS)

    Klar

    1980-01-01

    The reactor protection system being a part of the reactor safety system. The requirements on the reactor protection system are: high safety with regard to signal processing, high availability, self-reporting of faults etc. The functional sections of the reactor protection system are the analog section, the logic section and the generating of output signals. Description of the operation characteristics and of the extension of function. (orig.)

  20. Fall prevention and safety communication training for foremen: report of a pilot project designed to improve residential construction safety.

    Science.gov (United States)

    Kaskutas, Vicki; Dale, Ann Marie; Lipscomb, Hester; Evanoff, Brad

    2013-02-01

    Falls from heights account for 64% of residential construction worker fatalities and 20% of missed work days. We hypothesized that worker safety would improve with foremen training in fall prevention and safety communication. Training priorities identified through foreman and apprentice focus groups and surveys were integrated into an 8-hour training. We piloted the training with ten foremen employed by a residential builder. Carpenter trainers contrasted proper methods to protect workers from falls with methods observed at the foremen's worksites. Trainers presented methods to deliver toolbox talks and safety messages. Results from worksite observational audits (n=29) and foremen/crewmember surveys (n=97) administered before and after training were compared. We found that inexperienced workers are exposed to many fall hazards that they are often not prepared to negotiate. Fall protection is used inconsistently and worksite mentorship is often inadequate. Foremen feel pressured to meet productivity demands and some are unsure of the fall protection requirements. After the training, the frequency of daily mentoring and toolbox talks increased, and these talks became more interactive and focused on hazardous daily work tasks. Foremen observed their worksites for fall hazards more often. We observed increased compliance with fall protection and decreased unsafe behaviors during worksite audits. Designing the training to meet both foremen's and crewmembers' needs ensured the training was learner-centered and contextually-relevant. This pilot suggests that training residential foremen can increase use of fall protection, improve safety behaviors, and enhance on-the-job training and safety communication at their worksites. Construction workers' training should target safety communication and mentoring skills with workers who will lead work crews. Interventions at multiple levels are necessary to increase safety compliance in residential construction and decrease falls

  1. Prevalence and cost of imaging in inpatient falls: the rising cost of falling

    Directory of Open Access Journals (Sweden)

    Fields J

    2015-06-01

    Full Text Available Jessica Fields,1 Tahani Alturkistani,2 Neal Kumar,3 Arjun Kanuri,3 Deeb N Salem,1 Samson Munn,2 Deborah Blazey-Martin1 1Department of Medicine, Tufts Medical Center, Boston, MA, USA; 2Department of Radiology, Tufts Medical Center, Boston, MA, USA; 3Tufts University School of Medicine, Boston, MA, USA Objective: To quantify the type, prevalence, and cost of imaging following inpatient falls, identify factors associated with post-fall imaging, and determine correlates of positive versus negative imaging. Design: Single-center retrospective cohort study of inpatient falls. Data were collected from the hospital's adverse event reporting system, DrQuality. Age, sex, date, time, and location of fall, clinical service, Morse Fall Scale/fall protocol, admitting diagnosis, and fall-related imaging studies were reviewed. Cost included professional and facilities fees for each study. Setting: Four hundred and fifteen bed urban academic hospital over 3 years (2008–2010. Patients: All adult inpatient falls during the study period were included. Falls experienced by patients aged <18 years, outpatient and emergency patients, visitors to the hospital, and staff were excluded. Measurements and main results: Five hundred and thirty inpatient falls occurred during the study period, average patient age 60.7 years (range 20–98. More than half of falls were men (55% and patients considered at risk of falls (56%. Falls were evenly distributed across morning (33%, evening (34%, and night (33% shifts. Of 530 falls, 178 (34% patients were imaged with 262 studies. Twenty percent of patients imaged had at least one positive imaging study attributed to the fall and 82% of studies were negative. Total cost of imaging was $160,897, 63% ($100,700 from head computed tomography (CT. Conclusion: Inpatient falls affect patients of both sexes, all ages, occur at any time of day and lead to expensive imaging, mainly from head CTs. Further study should be targeted toward

  2. Development and Field Testing of the FootFall Planning System for the ATHLETE Robots

    Science.gov (United States)

    SunSpiral, Vytas; Wheeler, D. W.; Chavez-Clementa, Daniel; Mittman, David

    2011-01-01

    The FootFall Planning System is a ground-based planning and decision support system designed to facilitate the control of walking activities for the ATHLETE (All-Terrain Hex-Limbed Extra-Terrestrial Explorer) family of robots. ATHLETE was developed at NASA's Jet Propulsion Laboratory (JPL) and is a large six-legged robot designed to serve multiple roles during manned and unmanned missions to the Moon; its roles include transportation, construction and exploration. Over the four years from 2006 through 2010 the FootFall Planning System was developed and adapted to two generations of the ATHLETE robots and tested at two analog field sites (the Human Robotic Systems Project's Integrated Field Test at Moses Lake, Washington, June 2008, and the Desert Research and Technology Studies (D-RATS), held at Black Point Lava Flow in Arizona, September 2010). Having 42 degrees of kinematic freedom, standing to a maximum height of just over 4 meters, and having a payload capacity of 450 kg in Earth gravity, the current version of the ATHLETE robot is a uniquely complex system. A central challenge to this work was the compliance of the high-DOF (Degree Of Freedom) robot, especially the compliance of the wheels, which affected many aspects of statically-stable walking. This paper will review the history of the development of the FootFall system, sharing design decisions, field test experiences, and the lessons learned concerning compliance and self-awareness.

  3. Fall Down Detection Under Smart Home System.

    Science.gov (United States)

    Juang, Li-Hong; Wu, Ming-Ni

    2015-10-01

    Medical technology makes an inevitable trend for the elderly population, therefore the intelligent home care is an important direction for science and technology development, in particular, elderly in-home safety management issues become more and more important. In this research, a low of operation algorithm and using the triangular pattern rule are proposed, then can quickly detect fall-down movements of humanoid by the installation of a robot with camera vision at home that will be able to judge the fall-down movements of in-home elderly people in real time. In this paper, it will present a preliminary design and experimental results of fall-down movements from body posture that utilizes image pre-processing and three triangular-mass-central points to extract the characteristics. The result shows that the proposed method would adopt some characteristic value and the accuracy can reach up to 90 % for a single character posture. Furthermore the accuracy can be up to 100 % when a continuous-time sampling criterion and support vector machine (SVM) classifier are used.

  4. Regulatory control of physical protection systems

    International Nuclear Information System (INIS)

    Rajdeep; Mayya, Y.S.

    2017-01-01

    The safety of facilities in BARC is under the regulatory oversight of BSC. The security architecture for these facilities incorporates multiple layers of Physical Protection Systems. The demands of safety may sometimes conflict with the needs of security. Realizing the need to identify these interfaces and extend the regulatory coverage to Physical Protection Systems, a Standing Committee named Physical Protection System Review Committee (PPSRC) has been constituted as a 2"n"d tier entity of BSC. PPSRC includes experts from various domains concerned with nuclear security, viz. physical protection systems, cyber security, radiation safety, security operations, technical services and security administration

  5. Distributed Supervisory Protection Interlock System

    International Nuclear Information System (INIS)

    Walz, H.V.; Agostini, R.C.; Barker, L.; Cherkassky, R.; Constant, T.; Matheson, R.

    1989-03-01

    The Distributed Supervisory Protection Interlock System, DSPI, is under development at the Stanford Linear Accelerator Center for requirements in the areas of personnel protection, beam containment and equipment protection interlocks. The DSPI system, distributed over the application site, consists of segments with microprocessor-based controller and I/O modules, local area networks for communication, and a global supervisor computer. Segments are implemented with commercially available controller and I/O modules arranged in local interlock clusters, and associated software. Segments provide local interlock data acquisition, processing and control. Local area networks provide the communication backbone between segments and a global supervisor processor. The supervisor processor monitors the overall system, reports detail status and provides human interfaces. Details of an R and D test system, which will implement the requirements for personnel protection of 4 typical linear accelerator sectors, will be described. 4 refs., 2 figs

  6. Power system protection 2 systems and methods

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  7. Wind turbine with lightning protection system

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a wind turbine comprising a lightning protection system comprising a waveguide interconnecting a communication device and a signal-carrying structure. In other aspects, the present invention relates to the use of a waveguide in a lightning protection system...... of a wind turbine, a power splitter and its use in a lightning protection system of a wind turbine....

  8. Fall Detection Using Smartphone Audio Features.

    Science.gov (United States)

    Cheffena, Michael

    2016-07-01

    An automated fall detection system based on smartphone audio features is developed. The spectrogram, mel frequency cepstral coefficents (MFCCs), linear predictive coding (LPC), and matching pursuit (MP) features of different fall and no-fall sound events are extracted from experimental data. Based on the extracted audio features, four different machine learning classifiers: k-nearest neighbor classifier (k-NN), support vector machine (SVM), least squares method (LSM), and artificial neural network (ANN) are investigated for distinguishing between fall and no-fall events. For each audio feature, the performance of each classifier in terms of sensitivity, specificity, accuracy, and computational complexity is evaluated. The best performance is achieved using spectrogram features with ANN classifier with sensitivity, specificity, and accuracy all above 98%. The classifier also has acceptable computational requirement for training and testing. The system is applicable in home environments where the phone is placed in the vicinity of the user.

  9. Design Of Photovoltaic Powered Cathodic Protection System

    Directory of Open Access Journals (Sweden)

    Golina Samir Adly

    2017-07-01

    Full Text Available The corrosion caused by chemical reaction between metallic structures and surrounding mediums such as soil or water .the CP cathodic protection system is used to protect metallic structure against corrosion. Cathodic protection CP used to minimize corrosion by utilizing an external source of electrical current which forces the entire structure to become a cathode. There are two Types of cathodic protection system Galvanic current Impressed current.the Galvanic current is called a sacrificial anode is connected to the protected structure cathode through a DC power supply. In Galvanic current system a current passes from the sacrificing anode to the protected structure .the sacrificial anode is corroded rather than causing the protected structure corrosion .protected structure requires a constant current to stop the corrosion which determined by area structure metal and the surrounding medium. The rains humidity are decrease soil resistivity and increase the DC current .The corrosion and over protection resulting from increase in the DC current is harmful for the metallic structure. This problem can be solved by conventional cathodic protection system by manual adjustment of DC voltage periodically to obtain a constant current .the manual adjustment of DC voltage depends on experience of the technician and using the accuracy of the measuring equipment. The errors of measuring current depend on error from the technician or error from the measuring equipment. the corrosion of structure may occur when the interval between two successive adjustment is long .An automatically regulated cathodic protection system is used to overcome problems from conventional cathodic protection system .the regulated cathodic protection system adjust the DC voltage of the system automatically when it senses the variations of surrounding medium resistivity so the DC current is constant at the required level.

  10. The radioactive fall-out harm of nuclear burst to crops and its protection

    International Nuclear Information System (INIS)

    Zhao Wenhu; Xu Xinyu; Zhu Yongyi; Qiu Tongcai

    1990-10-01

    The radioactive contamination in the ground burst center is severe and the contaminated area is often large, as well as the effect of radioactive contamination is long. With different kinds of crops, the effects of external contamination caused by the fall-out are different. The contamination can easily be reduced by wind or rain. On the leaf surface it can be washed off and reduced to 10%. A small amount of fission product can be absorbed through plant roots. It is mainly distributed in leaves and stems. The radioactive contamination of fall-out would damage the crops and reduce the production. After an atmospheric test, the fall-out of 90 Sr and 137 Cs plays an important role in the biological effects. The absorption and distribution of radioactive contaminants in crops, their chemical states in soil and the measures to reduce the absorbed radioactivity are respectively studied

  11. Concurrent validation of an index to estimate fall risk in community dwelling seniors through a wireless sensor insole system: A pilot study.

    Science.gov (United States)

    Di Rosa, Mirko; Hausdorff, Jeff M; Stara, Vera; Rossi, Lorena; Glynn, Liam; Casey, Monica; Burkard, Stefan; Cherubini, Antonio

    2017-06-01

    Falls are a major health problem for older adults with immediate effects, such as fractures and head injuries, and longer term effects including fear of falling, loss of independence, and disability. The goals of the WIISEL project were to develop an unobtrusive, self-learning and wearable system aimed at assessing gait impairments and fall risk of older adults in the home setting; assessing activity and mobility in daily living conditions; identifying decline in mobility performance and detecting falls in the home setting. The WIISEL system was based on a pair of electronic insoles, able to transfer data to a commercially available smartphone, which was used to wirelessly collect data in real time from the insoles and transfer it to a backend computer server via mobile internet connection and then onwards to a gait analysis tool. Risk of falls was calculated by the system using a novel Fall Risk Index (FRI) based on multiple gait parameters and gait pattern recognition. The system was tested by twenty-nine older users and data collected by the insoles were compared with standardized functional tests with a concurrent validity approach. The results showed that the FRI captures the risk of falls with accuracy that is similar to that of conventional performance-based tests of fall risk. These preliminary findings support the idea that theWIISEL system can be a useful research tool and may have clinical utility for long-term monitoring of fall risk at home and in the community setting. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Falls following discharge after an in-hospital fall

    Directory of Open Access Journals (Sweden)

    Kessler Lori A

    2009-12-01

    Full Text Available Abstract Background Falls are among the most common adverse events reported in hospitalized patients. While there is a growing body of literature on fall prevention in the hospital, the data examining the fall rate and risk factors for falls in the immediate post-hospitalization period has not been well described. The objectives of the present study were to determine the fall rate of in-hospital fallers at home and to explore the risk factors for falls during the immediate post-hospitalization period. Methods We identified patients who sustained a fall on one of 16 medical/surgical nursing units during an inpatient admission to an urban community teaching hospital. After discharge, falls were ascertained using weekly telephone surveillance for 4 weeks post-discharge. Patients were followed until death, loss to follow up or end of study (four weeks. Time spent rehospitalized or institutionalized was censored in rate calculations. Results Of 95 hospitalized patients who fell during recruitment, 65 (68% met inclusion criteria and agreed to participate. These subjects contributed 1498 person-days to the study (mean duration of follow-up = 23 days. Seventy-five percent were African-American and 43% were women. Sixteen patients (25% had multiple falls during hospitalization and 23 patients (35% suffered a fall-related injury during hospitalization. Nineteen patients (29% experienced 38 falls at their homes, yielding a fall rate of 25.4/1,000 person-days (95% CI: 17.3-33.4. Twenty-three patients (35% were readmitted and 3(5% died. One patient experienced a hip fracture. In exploratory univariate analysis, persons who were likely to fall at home were those who sustained multiple falls in the hospital (p = 0.008. Conclusion Patients who fall during hospitalization, especially on more than one occasion, are at high risk for falling at home following hospital discharge. Interventions to reduce falls would be appropriate to test in this high-risk population.

  13. Site observational work plan for the UMTRA Project site at Falls City, Texas

    International Nuclear Information System (INIS)

    1995-06-01

    Produced by the US Department of Energy (DOE), this site observational work plan (SOWP) will be used to determine site-specific activities to comply with the US Environmental Protection Agency (EPA) ground water standards at this Uranium Mill Tailings Remedial Action (UMTRA) Project site. The purpose of the SOWP is to recommend a site-specific ground water compliance strategy at the Falls City UMTRA Project site. The Falls City SOWP presents a comprehensive summary of site hydrogeological data, delineates a conceptual model of the aquifer system, and discusses the origins of milling-related ground water contamination. It also defines the magnitude of ground water contamination, potential environmental and health risks associated with ground water contamination and data gaps, and targets a proposed compliance strategy

  14. Temporary physical protection systems

    International Nuclear Information System (INIS)

    Williams, J.D.; Gangel, D.J.; Madsen, R.W.

    1991-01-01

    Terrorism and other aspects of world political instability have created a high demand for temporary physical protection systems within the nuclear materials management community. They can be used when vehicles carrying important assets are away from their permanent fixed site location, around areas where experiments are being temporarily conducted, around construction areas and one portions of a fixed site physical security system which is temporarily inoperable. Physical security systems can be grouped into four categories: tactical, portable, semi-permanent, and fixed. The resources and experience gained at Sandia National Laboratories in over forty years of developing and implementing security systems for protecting nuclear weapons and fixed nuclear facilities is now being applied to temporary physical security systems. This paper emphasizes temporary physical security systems and their component parts that are presently available and identify additional system-subsystem objectives, requirements, and concepts

  15. Automatic recognition of falls in gait-slip training: Harness load cell based criteria.

    Science.gov (United States)

    Yang, Feng; Pai, Yi-Chung

    2011-08-11

    Over-head-harness systems, equipped with load cell sensors, are essential to the participants' safety and to the outcome assessment in perturbation training. The purpose of this study was to first develop an automatic outcome recognition criterion among young adults for gait-slip training and then verify such criterion among older adults. Each of 39 young and 71 older subjects, all protected by safety harness, experienced 8 unannounced, repeated slips, while walking on a 7m walkway. Each trial was monitored with a motion capture system, bilateral ground reaction force (GRF), harness force, and video recording. The fall trials were first unambiguously indentified with careful visual inspection of all video records. The recoveries without balance loss (in which subjects' trailing foot landed anteriorly to the slipping foot) were also first fully recognized from motion and GRF analyses. These analyses then set the gold standard for the outcome recognition with load cell measurements. Logistic regression analyses based on young subjects' data revealed that the peak load cell force was the best predictor of falls (with 100% accuracy) at the threshold of 30% body weight. On the other hand, the peak moving average force of load cell across 1s period, was the best predictor (with 100% accuracy) separating recoveries with backward balance loss (in which the recovery step landed posterior to slipping foot) from harness assistance at the threshold of 4.5% body weight. These threshold values were fully verified using the data from older adults (100% accuracy in recognizing falls). Because of the increasing popularity in the perturbation training coupling with the protective over-head-harness system, this new criterion could have far reaching implications in automatic outcome recognition during the movement therapy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. AUTOMATIC RECOGNITION OF FALLS IN GAIT-SLIP: A HARNESS LOAD CELL BASED CRITERION

    Science.gov (United States)

    Yang, Feng; Pai, Yi-Chung

    2012-01-01

    Over-head-harness systems, equipped with load cell sensors, are essential to the participants’ safety and to the outcome assessment in perturbation training. The purpose of this study was to first develop an automatic outcome recognition criterion among young adults for gait-slip training and then verify such criterion among older adults. Each of 39 young and 71 older subjects, all protected by safety harness, experienced 8 unannounced, repeated slips, while walking on a 7-m walkway. Each trial was monitored with a motion capture system, bilateral ground reaction force (GRF), harness force and video recording. The fall trials were first unambiguously indentified with careful visual inspection of all video records. The recoveries without balance loss (in which subjects’ trailing foot landed anteriorly to the slipping foot) were also first fully recognized from motion and GRF analyses. These analyses then set the gold standard for the outcome recognition with load cell measurements. Logistic regression analyses based on young subjects’ data revealed that peak load cell force was the best predictor of falls (with 100% accuracy) at the threshold of 30% body weight. On the other hand, the peak moving average force of load cell across 1-s period, was the best predictor (with 100% accuracy) separating recoveries with backward balance loss (in which the recovery step landed posterior to slipping foot) from harness assistance at the threshold of 4.5% body weight. These threshold values were fully verified using the data from older adults (100% accuracy in recognizing falls). Because of the increasing popularity in the perturbation training coupling with the protective over-head-harness system, this new criterion could have far reaching implications in automatic outcome recognition during the movement therapy. PMID:21696744

  17. Identity management and witness protection system

    OpenAIRE

    Paunović, Saša; Starčević, Dušan; Nešić, Lazar

    2013-01-01

    The protection of participants in criminal proceedings is one of the most important tools for prosecution of war crimes and organized crime cases. The paper presents the basic characteristics and the importance of implementing the Program of protection in criminal proceedings, with emphasis on the protection system and management of identity. Special attention was paid to challenges facing the protection system in criminal proceedings and the management of identities, which are caused by the ...

  18. Women's perspectives on falls and fall prevention during pregnancy.

    Science.gov (United States)

    Brewin, Dorothy; Naninni, Angela

    2014-01-01

    Falls are the leading cause of unintentional injury in women. During pregnancy, even a minor fall can result in adverse consequences. Evidence to inform effective and developmentally appropriate pregnancy fall prevention programs is lacking. Early research on pregnancy fall prevention suggests that exercise may reduce falls. However, acceptability and effectiveness of pregnancy fall prevention programs are untested. To better understand postpartum women's perspective and preferences on fall prevention strategies during pregnancy to formulate an intervention. Focus groups and individual interviews were conducted with 31 postpartum women using descriptive qualitative methodology. Discussion of falls during pregnancy and fall prevention strategies was guided by a focus group protocol and enhanced by 1- to 3-minute videos on proposed interventions. Focus groups were audio recorded, transcribed, and analyzed using NVivo 10 software. Emerging themes were environmental circumstances and physical changes of pregnancy leading to a fall, prevention strategies, barriers, safety concerns, and marketing a fall prevention program. Wet surfaces and inappropriate footwear commonly contributed to falls. Women preferred direct provider counseling and programs including yoga and Pilates. Fall prevention strategies tailored to pregnant women are needed. Perspectives of postpartum women support fall prevention through provider counseling and individual or supervised exercise programs.

  19. 78 FR 77574 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-12-24

    ... commissioning of power system protection systems.\\55\\ NERC commits in its Comments to keep the Commission... commissioning of power system protection systems.\\62\\ As explained in the NOPR, our concern is with a protection... protection system, ``resulting in line relays being placed in service with the incorrect transformer ratio...

  20. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  1. Smart cathodic protection systems

    NARCIS (Netherlands)

    Polder, R.B.; Leggedoor, J.; Schuten, G.; Sajna, S.; Kranjc, A.

    2010-01-01

    Cathodic protection delivers corrosion protection in concrete structures exposed to aggressive environments, e.g. in de-icing salt and marine climates. Working lives of a large number of CP systems are at least more than 13 years and probably more than 25 years, provided a minimum level of

  2. [Artificial intelligence] AI for protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aggarwal, R.; Johns, A.

    1997-12-31

    The reliable operation of large power systems with small stability margins is highly dependent on control systems and protection devices. Progress in the field of microprocessor systems and demanding requirements in respect of the performance of protective relays are the reasons for digital device applications to power system protection. The superiority of numeric protection over its analogue alternatives is attributed to such factors as accurate extraction of the fundamental voltage and current components through filtering, functional benefits resulting from multi-processor design and extensive self-monitoring, etc. However, all these reasons have not led to a major impact on speed, sensitivity and selectivity of primary protective relays, and the gains are only marginal; this is so because conventional digital relays still rely on deterministic signal models and a heuristic approach for decision making, so that only a fraction of the information contained within voltage and current signals as well as knowledge about the plant to be protected is used. The performance of digital relays may be substantially improved if the decision making is based on elements of artificial intelligence (AI). (Author)

  3. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ''what to protect against whom.'' The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met

  4. An integrated system for physical protection

    International Nuclear Information System (INIS)

    Kumar, Ranajit

    2001-01-01

    An Integrated Physical Protection System (IPPS) was developed for the consolidation of all sub systems, sensors and elements related to physical protection for an efficient and effective security environment of a facility. An effective physical protection system discharges the functions of detection, delay, communication, response, access control etc. IPPS performs, controls and monitors all the above functionality and helps in taking quick action on occurrence of unusual incidents by instantly reporting the incident in easily understandable audio, video, graphical and textual format and also by initiating automatic interactions among sub-systems

  5. Exploring the relationship between fall risk-increasing drugs and fall-related fractures.

    Science.gov (United States)

    De Winter, Sabrina; Vanwynsberghe, Sarah; Foulon, Veerle; Dejaeger, Eddy; Flamaing, Johan; Sermon, An; Van der Linden, Lorenz; Spriet, Isabel

    2016-04-01

    Hospital admissions due to fall-related fractures are a major problem in the aging population. Several risk factors have been identified, including drug use. Most studies often retrieved prescription-only drugs from national databases. These are associated with some limitations as they do not always reliably reproduce the complete patient's active drug list. To evaluate the association between the number of FRIDs intake identified by a standardised medication reconciliation process and a fall-related fracture leading to a hospital admission in older adults. The first cohort has been recruited from one traumatology ward of a tertiary teaching hospital in Belgium and the second cohort has been recruited from 11 community pharmacies in Belgium. A prospective study with two individually matched cohorts was performed. Adult patients (≥75 years) admitted with an injury due to a fall were included in the first cohort (faller group). The second cohort consisted of patients who did not suffer from a fall within the last 6 months (non-faller group). Matching was performed for age, gender, place of residence and use of a walking aid. In both groups, clinical pharmacists and undergraduate pharmacy students obtained the medication history, using a standardised approach. A list of drugs considered to increase the risk of falling was created. It included cardiovascular drugs and drugs acting on the nervous system. A linear mixed model was used to compare the number of fall risk-increasing drugs between fallers and non-fallers. The number of fall risk-increasing drugs in a faller versus a non-faller group. Sixty-one patients were matched with 121 non-fallers. Patients received on average 3.1 ± 2.1 and 3.2 ± 1.8 fall risk-increasing drugs in the faller and in the non-faller group, respectively. The mean number of fall risk-increasing drugs was comparable in both groups (p = 0.844), even after adjusting for alcohol consumption, fear of falling, vision and foot problems (p = 0

  6. Reactor protection system. Revision 1

    International Nuclear Information System (INIS)

    Fairbrother, D.B.; Vincent, D.R.; Lesniak, L.M.

    1975-04-01

    The reactor protection system-II (RPS-II) designed for use on Babcock and Wilcox 145- and 205-fuel assembly pressurized water reactors is described. In this system, relays in the trip logic have been replaced by solid state devices. A calculating module for the low DNBR, pump status, and offset trip functions has replaced the overpower trip (based on flow and imbalance), the power/RC pump trip, and the variable low pressure trip. Included is a description of the changes from the present Oconee-type reactor protection system (RPS-I), a functional and hardware description of the calculating module, and a discussion of the qualification program conducted to ensure that the degree of protection provided by RPS-II is not less than that provided by previously licensed systems supplied by B and W. (U.S.)

  7. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major US Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed in this paper. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. Finally, a list of measures is given for assessing overall physical protection system performance. (author)

  8. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1975-10-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely-activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. A list of measures is given for assessing overall physical protection system performance. (auth)

  9. Business model for sensor-based fall recognition systems.

    Science.gov (United States)

    Fachinger, Uwe; Schöpke, Birte

    2014-01-01

    AAL systems require, in addition to sophisticated and reliable technology, adequate business models for their launch and sustainable establishment. This paper presents the basic features of alternative business models for a sensor-based fall recognition system which was developed within the context of the "Lower Saxony Research Network Design of Environments for Ageing" (GAL). The models were developed parallel to the R&D process with successive adaptation and concretization. An overview of the basic features (i.e. nine partial models) of the business model is given and the mutual exclusive alternatives for each partial model are presented. The partial models are interconnected and the combinations of compatible alternatives lead to consistent alternative business models. However, in the current state, only initial concepts of alternative business models can be deduced. The next step will be to gather additional information to work out more detailed models.

  10. Observations on physical protection methods for protecting against unauthorized acts by an insider

    International Nuclear Information System (INIS)

    Ericson, D.M.; Goldman, L.A.; Lobner, R.R.

    1983-01-01

    Two basic approaches have evolved over the past several years for physical protection against sabotage by insiders. One, area-type physical protection, involves the use of access controls at area boundaries. Current practices at nuclear power plants generally fall into this category. The second, component-level physical protection, involves hardware at individual components as well as access controls at the boundary. The area-type physical protection concepts include team, area, and operational zoning. Team zoning requires the formation of multiperson teams that must be used to gain access to vital areas. Area zoning divides the plant into two or more zones, each of which is operated and maintained by separate, dedicated teams. Operational zoning is a closed-loop access control system that permits an initial vital area access, but blocks access to certain other vital areas until the operability of equipment in the first area is verified by test or inspection. Component-level physical protection is also a closed-loop system in which both area and component access are monitored. Each of the above measures can provide effective protection against an insider in certain instances, but each has weaknesses that must be recognized. An approach for protection against the insider is to take the most promising features of each of the above physical protection measures and supplement these capabilities with damage control and design changes as appropriate for a particular plant

  11. Static Posturography and Falls According to Pyramidal, Sensory and Cerebellar Functional Systems in People with Multiple Sclerosis

    Science.gov (United States)

    Kalron, Alon; Givon, Uri; Frid, Lior; Dolev, Mark; Achiron, Anat

    2016-01-01

    Balance impairment is common in people with multiple sclerosis (PwMS) and frequently impacts quality of life by decreasing mobility and increasing the risk of falling. However, there are only scarce data examining the contribution of specific neurological functional systems on balance measures in MS. Therefore, the primary aim of our study was to examine the differences in posturography parameters and fall incidence according to the pyramidal, cerebellar and sensory systems functional systems in PwMS. The study included 342 PwMS, 211 women and mean disease duration of 8.2 (S.D = 8.3) years. The study sample was divided into six groups according to the pyramidal, cerebellar and sensory functional system scores, derived from the Expanded Disability Status Scale (EDSS) data. Static postural control parameters were obtained from the Zebris FDM-T Treadmill (zebris® Medical GmbH, Germany). Participants were defined as "fallers" and "non-fallers" based on their fall history. Our findings revealed a trend that PwMS affected solely in the pyramidal system, have reduced stability compared to patients with cerebellar and sensory dysfunctions. Moreover, the addition of sensory impairments to pyramidal dysfunction does not exacerbate postural control. The patients in the pure sensory group demonstrated increased stability compared to each of the three combined groups; pyramidal-cerebellar, pyramidal-sensory and pyramidal-cerebellar-sensory groups. As for fall status, the percentage of fallers in the pure pyramidal, cerebellar and sensory groups were 44.3%, 33.3% and 19.5%, respectively. As for the combined functional system groups, the percentage of fallers in the pyramidal-cerebellar, pyramidal-sensory and pyramidal-cerebellar-sensory groups were 59.7%, 40.7% and 65%, respectively. This study confirms that disorders in neurological functional systems generate different effects on postural control and incidence of falls in the MS population. From a clinical standpoint, the

  12. Static Posturography and Falls According to Pyramidal, Sensory and Cerebellar Functional Systems in People with Multiple Sclerosis.

    Science.gov (United States)

    Kalron, Alon; Givon, Uri; Frid, Lior; Dolev, Mark; Achiron, Anat

    2016-01-01

    Balance impairment is common in people with multiple sclerosis (PwMS) and frequently impacts quality of life by decreasing mobility and increasing the risk of falling. However, there are only scarce data examining the contribution of specific neurological functional systems on balance measures in MS. Therefore, the primary aim of our study was to examine the differences in posturography parameters and fall incidence according to the pyramidal, cerebellar and sensory systems functional systems in PwMS. The study included 342 PwMS, 211 women and mean disease duration of 8.2 (S.D = 8.3) years. The study sample was divided into six groups according to the pyramidal, cerebellar and sensory functional system scores, derived from the Expanded Disability Status Scale (EDSS) data. Static postural control parameters were obtained from the Zebris FDM-T Treadmill (zebris® Medical GmbH, Germany). Participants were defined as "fallers" and "non-fallers" based on their fall history. Our findings revealed a trend that PwMS affected solely in the pyramidal system, have reduced stability compared to patients with cerebellar and sensory dysfunctions. Moreover, the addition of sensory impairments to pyramidal dysfunction does not exacerbate postural control. The patients in the pure sensory group demonstrated increased stability compared to each of the three combined groups; pyramidal-cerebellar, pyramidal-sensory and pyramidal-cerebellar-sensory groups. As for fall status, the percentage of fallers in the pure pyramidal, cerebellar and sensory groups were 44.3%, 33.3% and 19.5%, respectively. As for the combined functional system groups, the percentage of fallers in the pyramidal-cerebellar, pyramidal-sensory and pyramidal-cerebellar-sensory groups were 59.7%, 40.7% and 65%, respectively. This study confirms that disorders in neurological functional systems generate different effects on postural control and incidence of falls in the MS population. From a clinical standpoint, the

  13. Improved core protection calculator system algorithm

    International Nuclear Information System (INIS)

    Yoon, Tae Young; Park, Young Ho; In, Wang Kee; Bae, Jong Sik; Baeg, Seung Yeob

    2009-01-01

    Core Protection Calculator System (CPCS) is a digitized core protection system which provides core protection functions based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels which adapted a two out of four trip logic. CPCS algorithm improvement for the newly designed core protection calculator system, RCOPS (Reactor COre Protection System), is described in this paper. New features include the improvement of DNBR algorithm for thermal margin, the addition of pre trip alarm generation for auxiliary trip function, VOPT (Variable Over Power Trip) prevention during RPCS (Reactor Power Cutback System) actuation and the improvement of CEA (Control Element Assembly) signal checking algorithm. To verify the improved CPCS algorithm, CPCS algorithm verification tests, 'Module Test' and 'Unit Test', would be performed on RCOPS single channel facility. It is expected that the improved CPCS algorithm will increase DNBR margin and enhance the plant availability by reducing unnecessary reactor trips

  14. Availability analysis of supervised protective systems

    International Nuclear Information System (INIS)

    Kontoleon, N.; Kontoleon, J.M.; Chrysochoides, N.G.

    1975-01-01

    The behaviour in time of a nuclear reactor supervised protective system is modelled mathematically by a Markov process, continuous in time and with three discrete states. Failure and repair rates are assumed to be exponentially distributed. An analytical expression of system availability as a function of failure and repair rates as well as the inspection intervals and duration is derived. An optimization problem is then discussed in order to maximize system availability with respect to imposed cost constraints. Finally, an example of a supervised protective system with short inactive times is given, which may be found in many practical situations of modern protective systems. (author)

  15. Relationship between subjective fall risk assessment and falls and fall-related fractures in frail elderly people.

    Science.gov (United States)

    Shimada, Hiroyuki; Suzukawa, Megumi; Ishizaki, Tatsuro; Kobayashi, Kumiko; Kim, Hunkyung; Suzuki, Takao

    2011-08-12

    Objective measurements can be used to identify people with risks of falls, but many frail elderly adults cannot complete physical performance tests. The study examined the relationship between a subjective risk rating of specific tasks (SRRST) to screen for fall risks and falls and fall-related fractures in frail elderly people. The SRRST was investigated in 5,062 individuals aged 65 years or older who were utilized day-care services. The SRRST comprised 7 dichotomous questions to screen for fall risks during movements and behaviours such as walking, transferring, and wandering. The history of falls and fall-related fractures during the previous year was reported by participants or determined from an interview with the participant's family and care staff. All SRRST items showed significant differences between the participants with and without falls and fall-related fractures. In multiple logistic regression analysis adjusted for age, sex, diseases, and behavioural variables, the SRRST score was independently associated with history of falls and fractures. Odds ratios for those in the high-risk SRRST group (≥ 5 points) compared with the no risk SRRST group (0 point) were 6.15 (p fall, 15.04 (p falls, and 5.05 (p fall-related fractures. The results remained essentially unchanged in subgroup analysis accounting for locomotion status. These results suggest that subjective ratings by care staff can be utilized to determine the risks of falls and fall-related fractures in the frail elderly, however, these preliminary results require confirmation in further prospective research.

  16. The LHC quench protection system

    CERN Multimedia

    2009-01-01

    The new quench protection system (QPS) has the crucial roles of providing an early warning for any part of the superconducting coils and busbars that develop high resistance, as well as triggering the switch-off of the machine. Over 2000 new detectors will be installed around the LHC to make sure every busbar segment between magnets is monitored and protected. One of the major consolidation activities for the LHC is the addition of two new detectors to the quench protection system. A magnet quench occurs when part of the superconducting cable becomes normally-conducting. When the protection system detects an increased resistance the huge amount of energy stored in the magnet chains is safely extracted and ‘dumped’ into specially designed resistors. In the case of the main dipole chain, the stored energy in a single LHC sector is roughly the same as the kinetic energy of a passenger jet at cruising speed. The first new detector is designed to monitor the superconducting...

  17. Radiological protection system in the era of nuclear renaissance expectation for development of radiological protection system

    International Nuclear Information System (INIS)

    Toyomatsu, Hideki

    2008-01-01

    The current radiological protection system, which was established mainly by the ICRP and UNSCEAR, has contributed to the prevention of potential radiological health hazards, and has been a fundamental concept during the development of nuclear energy. Through a detailed discussion regarding the new ICRP recommendations, the world nuclear industry has reached a consensus that the current radiological protection system keeps its integrity in principle although it involves some remaining issues, such as the disposal of radioactive waste. In order to maximize the advantages of nuclear energy while keeping the integrity of radiological protection system, it is essential to address the characteristics of radiation, which is specific to nuclear energy, so that nuclear energy can coexist with other energy sources. The three basic principles of radiological protection (i.e., justification, optimization and dose limits), which were completed in the 1990 recommendations of ICRP, should be retained as the basic concepts for the future radiological protection system in order to maintain the continuity and consistency of the radiological protection system. The radiological protection system can be furthermore developed only by combining the above three principles with best practices extracted from utilities' field experience. The significant reduction of radiation exposures received by members of the public and radiation workers in the field has resulted from the efforts by the world utilities to achieve the optimization. In order to correctly apply the theory to the work practices, it is essential to see how the theory is practically used in the field. Such a process should be also emphasized in the revision work of the IAEA Basic Safety Standards (BSS), which is currently under progress. Integrating the theory in the work practices is the key to the true development of nuclear renaissance, which could lead to the establishment of the nuclear safety regime. (author)

  18. Improving safety culture in hospitals: Facilitators and barriers to implementation of Systemic Falls Investigative Method (SFIM).

    Science.gov (United States)

    Zecevic, Aleksandra A; Li, Alvin Ho-Ting; Ngo, Charity; Halligan, Michelle; Kothari, Anita

    2017-06-01

    The purpose of this study was to assess the facilitators and barriers to implementation of the Systemic Falls Investigative Method (SFIM) on selected hospital units. A cross-sectional explanatory mixed methods design was used to converge results from a standardized safety culture survey with themes that emerged from interviews and focus groups. Findings were organized by six elements of the Ottawa Model of Research Use framework. A geriatric rehabilitation unit of an acute care hospital and a neurological unit of a rehabilitation hospital were selected purposefully due to the high frequency of falls. Hospital staff who took part in: surveys (n = 39), interviews (n = 10) and focus groups (n = 12), and 38 people who were interviewed during falls investigations: fallers, family, unit staff and hospital management. Implementation of the SFIM to investigate fall occurrences. Percent of positive responses on the Modified Stanford Patient Safety Culture Survey Instrument converged with qualitative themes on facilitators and barriers for intervention implementation. Both hospital units had an overall poor safety culture which hindered intervention implementation. Facilitators were hospital accreditation, strong emphasis on patient safety, infrastructure and dedicated champions. Barriers included heavy workloads, lack of time, lack of resources and poor communication. Successful implementation of SFIM requires regulatory and organizational support, committed frontline staff and allocation of resources to identify active causes and latent contributing factors to falls. System-wide adjustments show promise for promotion of safety culture in hospitals where falls happen regularly. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. Power system protection 3 application

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  20. Electronic Out-fall Inspection Application - 12007

    Energy Technology Data Exchange (ETDEWEB)

    Weymouth, A Kent III; Pham, Minh; Messick, Chuck [Savannah River Nuclear Solutions, Aiken, South Carolina 29808 (United States)

    2012-07-01

    In early 2009 an exciting opportunity was presented to the Geographic Information Systems (GIS) team at the Savannah River Site (SRS). The SRS maintenance group was directed to maintain all Out-falls on Site, increasing their workload from 75 to 183 out-falls with no additional resources. The existing out-fall inspection system consisted of inspections performed manually and documented via paper trail. The inspections were closed out upon completion of activities and placed in file cabinets with no central location for tracking/trending maintenance activities. A platform for meeting new improvements required for documentation by the Department of Health and Environmental Control (DHEC) out-fall permits was needed to replace this current system that had been in place since the 1980's. This was accomplished by building a geographically aware electronic application that improved reliability of site out-fall maintenance and ensured consistent standards were maintained for environmental excellence and worker efficiency. Inspections are now performed via tablet and uploaded to a central point. Work orders are completed and closed either in the field using tablets (mobile application) or in their offices (via web portal) using PCs. And finally completed work orders are now stored in a central database allowing trending of maintenance activities. (authors)

  1. 46 CFR 153.460 - Fire protection systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Fire protection systems. 153.460 Section 153.460... Requirements for Flammable Or Combustible Cargoes § 153.460 Fire protection systems. Each self-propelled ship... protection system listed beside the cargo in Table 1 and described in the footnotes to Table 1. (b) The...

  2. Risk factors for falls and fall-related injuries in adults 85 years of age and older.

    Science.gov (United States)

    Grundstrom, Anna C; Guse, Clare E; Layde, Peter M

    2012-01-01

    Falls are a leading cause of morbidity and mortality in older adults. No previous studies on risk factors for falls have focused on adults 85 years and older, the most rapidly growing segment of adults. We examined demographic, health, and behavioral risk factors for falls and fall-related injuries in adults 65 years and older, with a particular focus on adults 85 years and older. We analyzed self-reported information from the Behavioral Risk Factor Surveillance System (BRFSS) for 2008. Data was available for 120,923 people aged 65 or older and 12,684 people aged 85 or older. Of those aged 85 or older, 21.3% reported at least one fall in the past 3 months and 7.2% reported at least one fall related injury requiring medical care or limiting activity for a day or longer. Below average general health, male sex, perceived insufficient sleep, health problems requiring assistive devices, alcohol consumption, increasing body mass index and history of stroke were all independently associated with a greater risk of falls or fall related injuries. The greater risk of falling in those 85 years and older appeared to be due to the deterioration of overall health status with age; among those with excellent overall health status, there was no greater risk of falling in adults 85 years and older compared to those 65-84 years of age. Our results suggest that those with risk factors for falls and fall-related injuries may be appropriate targets for evidence-based fall prevention programs. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  4. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  5. Healthcare Providers’ Perceptions and Self-Reported Fall Prevention Practices: Findings from a Large New York Health System

    Directory of Open Access Journals (Sweden)

    Matthew Lee eSmith

    2015-04-01

    Full Text Available Among older adults, falls are the leading cause of injury-related deaths and emergency department visits, and the incidence of falls in the United States is rising as the number of older Americans increases. Research has shown that falls can be reduced by modifying fall risk factors using multifactorial interventions implemented in clinical settings. However, the literature indicates many providers feel they do not know how to conduct fall risk assessments or do not have adequate knowledge about fall prevention To help healthcare providers incorporate older adult fall prevention (i.e., falls risk assessment and treatment into their clinical practice, the Centers for Disease Control and Prevention’s (CDC Injury Center has developed the STEADI (Stopping Elderly Accidents, Deaths, and Injuries tool kit. This study was conducted to identify the practice characteristics and providers’ beliefs, knowledge, and fall-related activities before they received training on how to use the STEADI tool kit. Data were collected as part of a larger State Fall Prevention Project funded by CDC’s Injury Center. Completed questionnaires were returned by 38 medical providers from 11 healthcare practices within a large New York health system. Healthcare providers ranked falls as the lowest priority of five conditions, after diabetes, cardiovascular disease, mental health, and musculoskeletal conditions. Less than 40% of the providers asked most or all of their older patients if they had fallen during the past 12 months. Less than a quarter referred their older patients to physical therapists for balance or gait training, and less than 20% referred older patients to community-based fall prevention programs. Less than 16% reported they conducted standardized functional assessments with their older patients at least once a year. These results suggest that implementing the STEADI tool kit in clinical settings could address knowledge gaps and provide the necessary

  6. Using a Medical Intranet of Things System to Prevent Bed Falls in an Acute Care Hospital: A Pilot Study

    Science.gov (United States)

    Wise, Diana; Ng, Chun Yin; Tso, Han-Wen; Chiang, Wan-Lin; Hutchinson, Aimee M; Galvin, Tracy; Hilborne, Lee; Hoffman, Cathy; Huang, Chi-Cheng; Wang, C Jason

    2017-01-01

    Background Hospitalized patients in the United States experience falls at a rate of 2.6 to 17.1 per 1000 patient-days, with the majority occurring when a patient is moving to, from, and around the bed. Each fall with injury costs an average of US $14,000. Objective The aim was to conduct a technology evaluation, including feasibility, usability, and user experience, of a medical sensor-based Intranet of things (IoT) system in facilitating nursing response to bed exits in an acute care hospital. Methods Patients 18 years and older with a Morse fall score of 45 or greater were recruited from a 35-bed medical-surgical ward in a 317-bed Massachusetts teaching hospital. Eligible patients were recruited between August 4, 2015 and July 31, 2016. Participants received a sensor pad placed between the top of their mattress and bed sheet. The sensor pad was positioned to monitor movement from patients’ shoulders to their thighs. The SensableCare System was evaluated for monitoring patient movement and delivering timely alerts to nursing staff via mobile devices when there appeared to be a bed-exit attempt. Sensor pad data were collected automatically from the system. The primary outcomes included number of falls, time to turn off bed-exit alerts, and the number of attempted bed-exit events. Data on patient falls were collected by clinical research assistants and confirmed with the unit nurse manager. Explanatory variables included room locations (zones 1-3), day of the week, nursing shift, and Morse Fall Scale (ie, positive fall history, positive secondary diagnosis, positive ambulatory aid, weak impaired gait/transfer, positive IV/saline lock, mentally forgets limitations). We also assessed user experience via nurse focus groups. Qualitative data regarding staff interactions with the system were collected during two focus groups with 25 total nurses, each lasting approximately 1.5 hours. Results A total of 91 patients used the system for 234.0 patient-days and experienced

  7. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration

  8. Advanced worker protection system

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-12-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration.

  9. Ageing vision and falls: a review.

    Science.gov (United States)

    Saftari, Liana Nafisa; Kwon, Oh-Sang

    2018-04-23

    Falls are the leading cause of accidental injury and death among older adults. One of three adults over the age of 65 years falls annually. As the size of elderly population increases, falls become a major concern for public health and there is a pressing need to understand the causes of falls thoroughly. While it is well documented that visual functions such as visual acuity, contrast sensitivity, and stereo acuity are correlated with fall risks, little attention has been paid to the relationship between falls and the ability of the visual system to perceive motion in the environment. The omission of visual motion perception in the literature is a critical gap because it is an essential function in maintaining balance. In the present article, we first review existing studies regarding visual risk factors for falls and the effect of ageing vision on falls. We then present a group of phenomena such as vection and sensory reweighting that provide information on how visual motion signals are used to maintain balance. We suggest that the current list of visual risk factors for falls should be elaborated by taking into account the relationship between visual motion perception and balance control.

  10. The correlation between white matter hyperintensity and balance disorder and fall risk: An observational, prospective cohort study.

    Science.gov (United States)

    Shen, Dong-Chao; Wu, Shuo-Lin; Shi, Yu-Zhi; Wang, Shuo; Zhang, Yu-Mei; Wang, Chun-Xue

    2016-09-01

    The presence of an association between white matter hyperintensity (WMH) and the risk of falls in older people is uncertain, with little supporting prospective evidence available at present. We aimed to determine whether WMH was associated with dysfunctions of balance and gait, and other sensorimotor factors leading to falls, and the independent factors related to falls in older Chinese people. The protective effect of exercise against falls was also addressed. In a representative sample of hospital-based individuals aged 50 years and older in China, the patients' history of falls, magnetic resonance imaging data, scores on the 9-item Berg Balance Scale (BBS-9) test and timed up-and-go test (TUGT), and sensorimotor measures of computerized dynamic posturography (CDP) were analyzed. Incident falls were recorded prospectively over a 12-month period. Using regression modeling, the association between the risk of falls and baseline WMH was estimated. Only individuals with severe WMH were at an increased risk of falls, and CDP was more sensitive than BBS-9 in detecting WMH-related balance and gait dysfunction. However, WMH was not an independent predictor of falls. Taller height and overweight or obese body habitus were identified as novel protective factors for falls. Female, fall history, and increased TUGT score were identified as independent risk factors for falls in older Chinese people. Although WMH was associated with an increased risk of falls, it was not an independent predictor.

  11. EMP protection procedure for electrical/electronic systems

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1976-01-01

    This paper presents a procedure for the protection engineer to follow in assessing a system with respect to its susceptibility to an electromagnetic pulse (EMP), and in determining whether the system requires protection. If the system is determined to be vulnerable to EMP, the procedure also indicates how to decide upon the most suitable protection scheme. The discussion centers on two flow charts, which illustrate the step-by-step procedure which utilizes the necessary ingredients of EMP protection engineering discussed in a previous paper. The description of the protection procedure is divided into two parts: the first dealing with issues on the macroscopic or large-scale system level, while the second is concerned with operations on the subsystem level or lower

  12. Image-based fall detection and classification of a user with a walking support system

    Science.gov (United States)

    Taghvaei, Sajjad; Kosuge, Kazuhiro

    2017-10-01

    The classification of visual human action is important in the development of systems that interact with humans. This study investigates an image-based classification of the human state while using a walking support system to improve the safety and dependability of these systems.We categorize the possible human behavior while utilizing a walker robot into eight states (i.e., sitting, standing, walking, and five falling types), and propose two different methods, namely, normal distribution and hidden Markov models (HMMs), to detect and recognize these states. The visual feature for the state classification is the centroid position of the upper body, which is extracted from the user's depth images. The first method shows that the centroid position follows a normal distribution while walking, which can be adopted to detect any non-walking state. The second method implements HMMs to detect and recognize these states. We then measure and compare the performance of both methods. The classification results are employed to control the motion of a passive-type walker (called "RT Walker") by activating its brakes in non-walking states. Thus, the system can be used for sit/stand support and fall prevention. The experiments are performed with four subjects, including an experienced physiotherapist. Results show that the algorithm can be adapted to the new user's motion pattern within 40 s, with a fall detection rate of 96.25% and state classification rate of 81.0%. The proposed method can be implemented to other abnormality detection/classification applications that employ depth image-sensing devices.

  13. Sandia Laboratories plutonium protection system

    International Nuclear Information System (INIS)

    Bernard, E.A.; Miyoshi, D.S.; Gutierrez, F.D.

    1977-01-01

    Sandia Laboratories is developing an improved plutonium protection system (PPS) to demonstrate new concepts for enhancing special nuclear materials safeguards. PPS concepts include separation of functions, real-time item accountability and improved means for control of materials, activities and personnel access. Physical barriers and a secure communications network are designed into the system to offer greater protection against sabotage, diversion and theft attempts. Prototype systems are being constructed at Hanford, Washington and Albuquerque, New Mexico and will be subjected to a comprehensive testing and evaluation program

  14. The Diamond machine protection system

    International Nuclear Information System (INIS)

    Heron, M.T.; Lay, S.; Chernousko, Y.; Hamadyk, P.; Rotolo, N.

    2012-01-01

    The Diamond Light Source Machine Protection System (MPS) manages the hazards from high power photon beams and other hazards to ensure equipment protection on the booster synchrotron and storage ring. The system has a shutdown requirement, on a beam mis-steer of under 1 msec and has to manage in excess of a thousand interlocks. This is realised using a combination of bespoke hardware and programmable logic controllers. The MPS monitors a large number of interlock signals from diagnostics instrumentation, vacuum instrumentation, photon front ends and plant monitoring subsystems. Based on logic it can then remove the source of the energy to ensure protection of equipment. Depending on requirements, interlocks are managed on a Local or a Global basis. The Global system is structured as two layers, and supports fast- and slow-response-time interlock requirements. A Global MPS module takes the interlock permits for a given interlock circuit from each of the cells of the accelerator, and, subject to all interlocks being good, produces a permit to operate the source of energy: the RF amplifier for vessel protection and the PSU for magnet protection. The Local MPS module takes fast Interlock inputs from one cell of the Storage Ring or one quadrant of the Booster. Fast interlocks are those that must drop the beam in under 400 μsec (the maximum speed of the interlock) in the event of failure. EPIC provides the user interface to the MPS system

  15. Relationship between subjective fall risk assessment and falls and fall-related fractures in frail elderly people

    Directory of Open Access Journals (Sweden)

    Shimada Hiroyuki

    2011-08-01

    Full Text Available Abstract Background Objective measurements can be used to identify people with risks of falls, but many frail elderly adults cannot complete physical performance tests. The study examined the relationship between a subjective risk rating of specific tasks (SRRST to screen for fall risks and falls and fall-related fractures in frail elderly people. Methods The SRRST was investigated in 5,062 individuals aged 65 years or older who were utilized day-care services. The SRRST comprised 7 dichotomous questions to screen for fall risks during movements and behaviours such as walking, transferring, and wandering. The history of falls and fall-related fractures during the previous year was reported by participants or determined from an interview with the participant's family and care staff. Results All SRRST items showed significant differences between the participants with and without falls and fall-related fractures. In multiple logistic regression analysis adjusted for age, sex, diseases, and behavioural variables, the SRRST score was independently associated with history of falls and fractures. Odds ratios for those in the high-risk SRRST group (≥ 5 points compared with the no risk SRRST group (0 point were 6.15 (p Conclusion These results suggest that subjective ratings by care staff can be utilized to determine the risks of falls and fall-related fractures in the frail elderly, however, these preliminary results require confirmation in further prospective research.

  16. The correlation between white matter hyperintensity and balance disorder and fall risk: An observational, prospective cohort study

    Directory of Open Access Journals (Sweden)

    Dong-Chao Shen

    2016-09-01

    Full Text Available Objective: The presence of an association between white matter hyperintensity (WMH and the risk of falls in older people is uncertain, with little supporting prospective evidence available at present. We aimed to determine whether WMH was associated with dysfunctions of balance and gait, and other sensorimotor factors leading to falls, and the independent factors related to falls in older Chinese people. The protective effect of exercise against falls was also addressed. Methods: In a representative sample of hospital-based individuals aged 50 years and older in China, the patients' history of falls, magnetic resonance imaging data, scores on the 9-item Berg Balance Scale (BBS-9 test and timed up-and-go test (TUGT, and sensorimotor measures of computerized dynamic posturography (CDP were analyzed. Incident falls were recorded prospectively over a 12-month period. Using regression modeling, the association between the risk of falls and baseline WMH was estimated. Results: Only individuals with severe WMH were at an increased risk of falls, and CDP was more sensitive than BBS-9 in detecting WMH-related balance and gait dysfunction. However, WMH was not an independent predictor of falls. Taller height and overweight or obese body habitus were identified as novel protective factors for falls. Female, fall history, and increased TUGT score were identified as independent risk factors for falls in older Chinese people. Conclusion: Although WMH was associated with an increased risk of falls, it was not an independent predictor. Keywords: White matter hyperintensity, Balance disorder, Gait disorder, Fall risk

  17. Patient centered fall risk awareness perspectives: clinical correlates and fall risk

    Science.gov (United States)

    Verghese, Joe

    2016-01-01

    Background While objective measures to assess risk of falls in older adults have been established; the value of patient self-reports in the context of falls is not known. Objectives To identify clinical correlates of patient centered fall risk awareness, and their validity for predicting falls. Design Prospective cohort study. Setting and Participants 316 non-demented and ambulatory community-dwelling older adults (mean age 78 years, 55% women). Measurements Fall risk awareness was assessed with a two-item questionnaire, which asked participants about overall likelihood and personal risk of falling over the next 12 months. Incident falls were recorded over study follow-up. Results Fifty-three participants (16.8%) responded positively to the first fall risk awareness question about being likely to have a fall in the next 12 months, and 100 (31.6%) reported being at personal risk of falling over the next 12 months. There was only fair correlation (kappa 0.370) between responses on the two questions. Prior falls and depressive symptoms were associated with positive responses on both fall risk awareness questions. Age and other established fall risk factors were not associated with responses on both fall risk awareness questions. The fall risk awareness questionnaire did not predict incident falls or injurious falls. Conclusion Fall risk awareness is low in older adults. While patient centered fall risk awareness is not predictive of falls, subjective risk perceptions should be considered when designing fall preventive strategies as they may influence participation and behaviors. PMID:27801936

  18. Fall-related activity avoidance in relation to a history of falls or near falls, fear of falling and disease severity in people with Parkinson's disease.

    Science.gov (United States)

    Kader, Manzur; Iwarsson, Susanne; Odin, Per; Nilsson, Maria H

    2016-06-02

    There is limited knowledge concerning fall-related activity avoidance in people with Parkinson's disease (PD); such knowledge would be of importance for the development of more efficient PD-care and rehabilitation. This study aimed to examine how fall-related activity avoidance relates to a history of self-reported falls/near falls and fear of falling (FOF) as well as to disease severity in people with PD. Data were collected from 251 (61 % men) participants with PD; their median (min-max) age and PD duration were 70 (45-93) and 8 (1-43) years, respectively. A self-administered postal survey preceded a home visit which included observations, clinical tests and interview-administered questionnaires. Fall-related activity avoidance was assessed using the modified Survey of Activities and Fear of Falling in the Elderly (mSAFFE) as well as by using a dichotomous (Yes/No) question. Further dichotomous questions concerned: the presence of FOF and the history (past 6 months) of falls or near falls, followed by stating the number of incidents. Disease severity was assessed according to the Hoehn and Yahr (HY) stages. In the total sample (n = 251), 41 % of the participants reported fall-related activity avoidance; the median mSAFFE score was 22. In relation to a history of fall, the proportions of participants (p fall-related activity avoidance were: non-fallers (30 %), single fallers (50 %) and recurrent fallers, i.e. ≥ 2 falls (57 %). Among those that reported near falls (but no falls), 51 % (26 out of 51) reported fall-related activity avoidance. Of those that reported FOF, 70 % reported fall-related activity avoidance. Fall-related activity avoidance ranged from 24 % in the early PD-stage (HY I) to 74 % in the most severe stages (HY IV-V). Results indicate that fall-related activity avoidance may be related to a history of self-reported falls/near falls, FOF and disease severity in people with PD. Importantly, fall-related activity avoidance is

  19. Evaluation of an inpatient fall risk screening tool to identify the most critical fall risk factors in inpatients.

    Science.gov (United States)

    Hou, Wen-Hsuan; Kang, Chun-Mei; Ho, Mu-Hsing; Kuo, Jessie Ming-Chuan; Chen, Hsiao-Lien; Chang, Wen-Yin

    2017-03-01

    To evaluate the accuracy of the inpatient fall risk screening tool and to identify the most critical fall risk factors in inpatients. Variations exist in several screening tools applied in acute care hospitals for examining risk factors for falls and identifying high-risk inpatients. Secondary data analysis. A subset of inpatient data for the period from June 2011-June 2014 was extracted from the nursing information system and adverse event reporting system of an 818-bed teaching medical centre in Taipei. Data were analysed using descriptive statistics, receiver operating characteristic curve analysis and logistic regression analysis. During the study period, 205 fallers and 37,232 nonfallers were identified. The results revealed that the inpatient fall risk screening tool (cut-off point of ≥3) had a low sensitivity level (60%), satisfactory specificity (87%), a positive predictive value of 2·0% and a negative predictive value of 99%. The receiver operating characteristic curve analysis revealed an area under the curve of 0·805 (sensitivity, 71·8%; specificity, 78%). To increase the sensitivity values, the Youden index suggests at least 1·5 points to be the most suitable cut-off point for the inpatient fall risk screening tool. Multivariate logistic regression analysis revealed a considerably increased fall risk in patients with impaired balance and impaired elimination. The fall risk factor was also significantly associated with days of hospital stay and with admission to surgical wards. The findings can raise awareness about the two most critical risk factors for falls among future clinical nurses and other healthcare professionals and thus facilitate the development of fall prevention interventions. This study highlights the needs for redefining the cut-off points of the inpatient fall risk screening tool to effectively identify inpatients at a high risk of falls. Furthermore, inpatients with impaired balance and impaired elimination should be closely

  20. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1977-01-01

    Reactor Protection Systems for Nuclear Power Plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. This paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  1. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1976-01-01

    Reactor protection systems for nuclear power plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. The paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  2. Comparison, with regard to safety, between a hard-wired reactor protection system and a computerized protection system. Pt. 1

    International Nuclear Information System (INIS)

    Buettner, W.E.

    1976-07-01

    The study compares a conventional hard-wired dynamic reactor protection system with a computerized protection system. In the comparison, only the unequivocally safety-oriented protection actions are considered. In the first part, the different structures of both systems and the method of verification for their functional safety will be described. In the second part, the mean unavailability in case of demand for both systems under defined conditions will be determined. (orig.) [de

  3. Management information system on radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela, E-mail: pabloag@cdtn.b, E-mail: lss@cdtn.b, E-mail: gmf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  4. Management information system on radiation protection

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela

    2011-01-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  5. Developing a falls prevention program for community-dwelling stroke survivors in Singapore: client and caregiver perspectives.

    Science.gov (United States)

    Xu, Tianma; O'Loughlin, Kate; Clemson, Lindy; Lannin, Natasha A; Dean, Catherine; Koh, Gerald

    2017-12-25

    Drawing on the perspectives of stroke survivors, family members and domestic helpers, this study explores participants' experiences of self-perceived fall risk factors after stroke, common fall prevention strategies used, and challenges to community participation after a fall. Semi-structured interviews were conducted in Singapore with community-dwelling stroke survivors with a previous fall (n = 9), family caregivers (n = 4), and domestic helpers (n = 4) who have cared for a stroke survivor with a previous fall. Purposive sampling was used for recruitment; all interviews were audio-recorded with permission and transcribed. Thematic analysis was conducted using NVivo (v10) software. All participants shared their self-perceived intrinsic and extrinsic fall risk factors and main challenges after a fall. For stroke participants and family caregivers, motivational factors in developing safety strategies after a previous fall(s) include social connectedness, independent living and community participation. For family caregivers and domestic helpers, the stroke survivor's safety is their top priority, however this can also lead to over-protective behavior outside of the rehabilitation process. Reducing the risk of falls in community-dwelling stroke survivors seems to be more important than promoting community participation among caregivers. The study findings highlight that a structured and client-centered fall prevention program targeting stroke survivors and caregivers is needed in Singapore. Implications for rehabilitation Falls after stroke can lead to functional decline in gait and mobility and restricted self-care activities. Community-dwelling stroke survivors develop adaptive safety strategies after a fall and want to be socially connected. However, caregivers see the safety of the stroke survivors as their top priority and demonstrate over-protective behaviors. Fall prevention programs for community-dwelling stroke survivors should target both stroke

  6. Person-Centered Fall Risk Awareness Perspectives: Clinical Correlates and Fall Risk.

    Science.gov (United States)

    Verghese, Joe

    2016-12-01

    To identify clinical correlates of person-centered fall risk awareness and their validity for predicting falls. Prospective cohort study. Community. Ambulatory community-dwelling older adults without dementia (N = 316; mean age 78, 55% female). Fall risk awareness was assessed using a two-item questionnaire that asked participants about overall likelihood of someone in their age group having a fall and their own personal risk of falling over the next 12 months. Incident falls were recorded over study follow-up. Fifty-three participants (16.8%) responded positively to the first fall risk awareness question about being likely to have a fall in the next 12 months, and 100 (31.6%) reported being at personal risk of falling over the next 12 months. There was only fair correlation (κ = 0.370) between responses on the two questions. Prior falls and depressive symptoms were associated with positive responses on both fall risk awareness questions. Age and other established fall risk factors were not associated with responses on either fall risk awareness question. The fall risk awareness questionnaire did not predict incident falls or injurious falls. Fall risk awareness is low in older adults. Although person-centered fall risk awareness is not predictive of falls, subjective risk perceptions should be considered when designing fall preventive strategies because they may influence participation and behaviors. © 2016, Copyright the Author Journal compilation © 2016, The American Geriatrics Society.

  7. Impact of Diabetic Complications on Balance and Falls: Contribution of the Vestibular System

    OpenAIRE

    D'Silva, Linda J.; Lin, James; Staecker, Hinrich; Whitney, Susan L.; Kluding, Patricia M.

    2015-01-01

    Diabetes causes many complications, including retinopathy and peripheral neuropathy, which are well understood as contributing to gait instability and falls. A less understood complication of diabetes is the effect on the vestibular system. The vestibular system contributes significantly to balance in static and dynamic conditions by providing spatially orienting information. It is noteworthy that diabetes has been reported to affect vestibular function in both animal and clinical studies. Pa...

  8. Development of a helmet-mounted PLZT thermal/flash protection system

    International Nuclear Information System (INIS)

    Harris, J.O. Jr.; Cutchen, J.T.; Pfoff, B.J.

    1976-01-01

    Sandia Laboratories is developing PLZT thermal/flash protective devices (TFPD's) goggles to prevent exposure and resultant eye damage from nuclear weapon detonations. The primary emphasis of the present program is to transfer technology and establish production capability for helmet-mounted PLZT/TFPD goggles for USAF flight crews, with a non-helmet-mounted configuration to follow. The first production units are anticipated in the fall of 1977. The operating principles of the PLZT/TFPD goggle device are briefly outlined, and the device configuration and operational characteristics are described

  9. Falls and Fear of Falling After Stroke: A Case-Control Study.

    Science.gov (United States)

    Goh, Hui-Ting; Nadarajah, Mohanasuntharaam; Hamzah, Norhamizan Binti; Varadan, Parimalaganthi; Tan, Maw Pin

    2016-12-01

    Falls are common after stroke, with potentially serious consequences. Few investigations have included age-matched control participants to directly compare fall characteristics between older adults with and without stroke. Further, fear of falling, a significant psychological consequence of falls, has only been examined to a limited degree as a risk factor for future falls in a stroke population. To compare the fall history between older adults with and without a previous stroke and to identify the determinants of falls and fear of falling in older stroke survivors. Case-control observational study. Primary teaching hospital. Seventy-five patients with stroke (mean age ± standard deviation, 66 ± 7 years) and 50 age-matched control participants with no previous stroke were tested. Fall history, fear of falling, and physical, cognitive, and psychological function were assessed. A χ 2 test was performed to compare characteristics between groups, and logistic regression was performed to determine the risk factors for falls and fear of falling. Fall events in the past 12 months, Fall Efficacy Scale-International, Berg Balance Scale, Functional Ambulation Category, Fatigue Severity Scale, Montreal Cognitive Assessment, and Patient Healthy Questionnaire-9 were measured for all participants. Fugl-Meyer Motor Assessment was used to quantify severity of stroke motor impairments. Twenty-three patients and 13 control participants reported at least one fall in the past 12 months (P = .58). Nine participants with stroke had recurrent falls (≥2 falls) compared with none of the control participants (P falling than did nonstroke control participants (P falls in the nonstroke group, whereas falls in the stroke group were not significantly associated with any measured outcomes. Fear of falling in the stroke group was associated with functional ambulation level and balance. Functional ambulation level alone explained 22% of variance in fear of falling in the stroke group

  10. Advanced Protection & Service Restoration for FREEDM Systems

    Science.gov (United States)

    Singh, Urvir

    A smart electric power distribution system (FREEDM system) that incorporates DERs (Distributed Energy Resources), SSTs (Solid State Transformers - that can limit the fault current to two times of the rated current) & RSC (Reliable & Secure Communication) capabilities has been studied in this work in order to develop its appropriate protection & service restoration techniques. First, a solution is proposed that can make conventional protective devices be able to provide effective protection for FREEDM systems. Results show that although this scheme can provide required protection but it can be quite slow. Using the FREEDM system's communication capabilities, a communication assisted Overcurrent (O/C) protection scheme is proposed & results show that by using communication (blocking signals) very fast operating times are achieved thereby, mitigating the problem of conventional O/C scheme. Using the FREEDM System's DGI (Distributed Grid Intelligence) capability, an automated FLISR (Fault Location, Isolation & Service Restoration) scheme is proposed that is based on the concept of 'software agents' & uses lesser data (than conventional centralized approaches). Test results illustrated that this scheme is able to provide a global optimal system reconfiguration for service restoration.

  11. Fear of falling as seen in the Multidisciplinary falls consultation.

    Science.gov (United States)

    Gaxatte, C; Nguyen, T; Chourabi, F; Salleron, J; Pardessus, V; Delabrière, I; Thévenon, A; Puisieux, F

    2011-06-01

    Fear of falling may be as debilitating as the fall itself, leading to a restriction in activities and even a loss of autonomy. The main objective was to evaluate the prevalence of the fear of falling among elderly fallers. The secondary objectives were to determine the factors associated with the fear of falling and evaluate the impact of this fear on the activity "getting out of the house". Prospective study conducted between 1995 and 2006 in which fallers and patients at high risk for falling were seen at baseline by the multidisciplinary falls consultation team (including a geriatrician, a neurologist and a physical medicine and rehabilitation physician) and then, again 6 month later, by the same geriatrician. The fear of falling was evaluated with a yes/no question: "are you afraid of falling?". Out of 635 patients with a mean age of 80.6 years, 502 patients (78%) expressed a fear of falling. Patients with fear of falling were not older than those who did not report this fear, but the former were mostly women (Pfear of falling were not going out alone as much as the fearless group (31% vs 53%, Pfearful group admitted to avoiding going out because they were afraid of falling. The strong prevalence of the fear of falling observed in this population and its consequences in terms of restricted activities justifies systematically screening for it in fallers or patients at risk for falling. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  12. Reactor protection systems of 500 MWe PHWRs

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, G; Kelkar, M G; Apte, Ravindra [C and I Group, Nuclear Power Corporation, Mumbai (India)

    1997-03-01

    The 500 MWe PHWR has two totally independent, diverse, fast acting shutdown system called Shutdown System 1 (SDS 1) and Shutdown System 2 (SDS 2). The trip generation circuitry of SDS 1 and SDS 2 are known as Reactor Protection System 1 (RPS 1) and Reactor Protection System 2 (RPS 2) respectively. Some of the features specific to 500 MWe reactors are Core Over Power Protection System (COPPS) based upon in core Self Powered Neutron Detector (SPND) signals, use of local two out of three coincidence logic and adoption of overlap testing for RPS 2, use of Fine Impulse Testing (FIT) in RPS 2, testing of the final control elements namely electro-magnetic clutch of individual Shutoff Rods (SRs) of SDS 1 and all the fast acting valves of SDS 2, etc. The two shutdown systems have totally separate sets of sensors and associated signal processing circuitry as well as physical arrangements. A separate computerised test and monitoring unit is used for each of the two shutdown systems. Use of Programmable Digital Comparator (PDC) unit exclusively for reactor protection systems, has been adopted. The capability of PDC unit is enhanced and communication links are provided for its integration in over all system. The paper describes the design features of reactor protection systems. (author). 3 refs., 7 figs., 3 tabs.

  13. Falling and fall risk in adult patients with severe haemophilia.

    Science.gov (United States)

    Rehm, Hanna; Schmolders, Jan; Koob, Sebastian; Bornemann, Rahel; Goldmann, Georg; Oldenburg, Johannes; Pennekamp, Peter; Strauss, Andreas C

    2017-05-10

    The objective of this study was to define fall rates and to identify possible fall risk factors in adult patients with severe haemophilia. 147 patients with severe haemophilia A and B were evaluated using a standardized test battery consisting of demographic, medical and clinical variables and fall evaluation. 41 (27.9 %) patients reported a fall in the past 12 months, 22 (53.7 %) of them more than once. Young age, subjective gait insecurity and a higher number of artificial joints seem to be risk factors for falling. Falls seem to be a common phenomenon in patients with severe haemophilia. Fall risk screening and fall prevention should be implemented into daily practice.

  14. Albeni Falls Wildlife Management Plan - preliminary environmental assessment

    International Nuclear Information System (INIS)

    1996-04-01

    Bonneville Power Administration (BPA) proposes to fund the development and implementation of the Albeni Falls Wildlife Management Plan. Approved by the Northwest Power Planning Council (Council) in 1990, the project is a cooperative effort with the Interagency Work Group that includes the Idaho Department of Fish and Game (IDFG); United States Fish and Wildlife Service (USFWS); United States Forest Service (USFS); United States Army Corps of Engineers (COE); the Kalispel Tribe; and the Upper Columbia United Tribes (UCUT). The proposed action would enable the Interagency Work Group to protect and enhance a variety of wetland and riparian habitats, restore 28,587 habitat units lost as a result of the construction and operation of Albeni Falls Dam, and implement long-term wildlife management activities at selected sites within the overall study area. This Environmental Assessment (EA) examines the potential environmental effects of protecting and enhancing wildlife habitat in selected portions of a 225,077 hectare (556,160 acre) study area surrounding Lake Pend Oreille in Bonner County, and 7,770 hectare (19,200 acre) area surrounding Spirit and Twin lakes, in Kootenai County, Idaho. Four proposed activities are analyzed: habitat protection; habitat enhancement; operation and maintenance (O ampersand M); and monitoring and evaluation (M ampersand E)

  15. 29 CFR Appendix B to Subpart I of... - General Testing Conditions and Additional Guidelines for Personal Fall Protection Systems (Non...

    Science.gov (United States)

    2010-07-01

    ..., to its hanging location (6 feet (1.83 m) below the anchorage). The test weight should fall without... belts, the complete belt should withstand a drop test consisting of a 250 pound (113.4 kg) weight.... One belt terminal should be attached to a rigid anchor and the other terminal should hang free. The...

  16. Falls prevention in hospitals and mental health units: an extended evaluation of the FallSafe quality improvement project.

    Science.gov (United States)

    Healey, Frances; Lowe, Derek; Darowski, Adam; Windsor, Julie; Treml, Jonathan; Byrne, Lisa; Husk, Janet; Phipps, Jill

    2014-07-01

    inpatient falls are a major patient safety issue causing distress, injury and death. Systematic review suggests multifactorial assessment and intervention can reduce falls by 20-30%, but large-scale studies of implementation are few. This paper describes an extended evaluation of the FallSafe quality improvement project, which presented key components of multifactorial assessment and intervention as a care bundle. : data on delivery of falls prevention processes were collected at baseline and for 18 months from nine FallSafe units and nine control units. Data on falls were collected from local risk management systems for 24 months, and data on under-reporting through staff surveys. : in FallSafe units, delivery of seven care bundle components significantly improved; most improvements were sustained after active project support was withdrawn. Twelve-month moving average of reported fall rates showed a consistent downward trend in FallSafe units but not controls. Significant reductions in reported fall rate were found in FallSafe units (adjusted rate ratio (ARR) 0.75, 95% confidence interval (CI) 0.68-0.84 P control units (ARR 0.91, 95% CI 0.81-1.03 P = 0.13). No significant changes in injurious fall rate were found in FallSafe units (ARR 0.86, 95% CI 0.71-1.03 P = 0.11), or controls (ARR 0.88, 95% CI 0.72-1.08 P = 0.13). In FallSafe units, staff certain falls had been reported increased from 60 to 77%. : introducing evidence-based care bundles of multifactorial assessment and intervention using a quality improvement approach resulted in improved delivery of multifactorial assessment and intervention and significant reductions in fall rates, but not in injurious fall rates. © The Author 2013. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Falling into the Light-using music and poetry as complementary modes of understanding falls in old age

    DEFF Research Database (Denmark)

    Evron, Lotte; Clausen, Nina

    that a broader understanding of falls in old age in the health care system might help health professionals to understand the complexity of falls and by this inspire older persons to prevent falls in different ways. Using poetry and music in our performance we seek to open up for a broader understanding of falls......: irresponsible behavior, disease, destiny, desire to remain independent in old age, appearing elegant/aesthetical and being physical active. One of the interviews was selected and transformed it into a poem (2-3). The poem was then translated into music by the second author. First we present the six...... understandings of falls in old age then we read the poem and finally a musical interpretation of the poem is performed by song and cello. The music is written for soprano and cello and created with direct inspiration from the poem. The fall is reproduced in a series of descending tones coming back as a "chorus...

  18. 49 CFR 214.115 - Foot protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Foot protection. 214.115 Section 214.115... protection. (a) The railroad or railroad contractor shall require railroad bridge workers to wear foot protection equipment when potential foot injury may result from impact, falling or flying objects, electrical...

  19. Analysis Of First Fall And Last Spring Advection and Radiation-Advection Frosts In Azerbaijan Provinces

    International Nuclear Information System (INIS)

    Noohi, K.; Pedram, M.; Sahraian, F.; Kamali, G. A.

    2007-01-01

    Atmospheric Science and Meteorological Research Center (ASMERC)Dates of first fall and last spring frosts on the basis of minimum shelter temperature equal or less than 0°C were determined for 12 synoptic stations for period 1986-2000 in Azerbaijan region. The advection frost was determined based on using of synoptic maps and studying of meteorological elements in different hours. In this work, we found that series of first fall and last spring advection and radiation-advection frosts are random and normally distributed. This study shows that on the average advection frosts start from 6 to 40 days later than radiation-advection frosts in fall and ends 2 to 25 days earlier in spring. Potential growing season that is interval between last spring and first fall advection frost is found to be from 5 to 65 days longer than the growing season defined by the interval from last spring to first fall occurrences of minimum temperature equal or less than 0°C. Crop protection against radiation frosts can bring about too much benefit. To assess whether practical protection of some special crops against radiation frosts is done or not, the number of radiation frosts before first advection frost in fall and after last advection frost in spring, were determined

  20. Fall cover crops boost soil arbuscular mycorrhizal fungi which can lead to reduced inputs

    Science.gov (United States)

    Fall cover crops provide multiple benefits to producers. These benefits include pathogen and pest protection, drought protection, weed control, reduced soil erosion, nutrient acquisition and retention, increased soil organic matter, and conservation of soil water by improvement of soil structure th...

  1. Accidents due to falls from roof slabs.

    Science.gov (United States)

    Rudelli, Bruno Alves; Silva, Marcelo Valerio Alabarce da; Akkari, Miguel; Santili, Claudio

    2013-01-01

    CONTEXT AND OBJECTIVE Falls from the roof slabs of houses are accidents of high potential severity that occur in large Brazilian cities and often affect children and adolescents. The aims of this study were to characterize the factors that predispose towards this type of fall involving children and adolescents, quantify the severity of associated lesions and suggest preventive measures. DESIGN AND SETTING Descriptive observational prospective longitudinal study in two hospitals in the metropolitan region of São Paulo. METHODS Data were collected from 29 cases of falls from roof slabs involving children and adolescents between October 2008 and October 2009. RESULTS Cases involving males were more prevalent, accounting for 84%. The predominant age group was schoolchildren (7 to 12 years old; 44%). Leisure activities were most frequently being practiced on the roof slab at the time of the fall (86%), and flying a kite was the most prevalent game (37.9%). In 72% of the cases, the children were unaccompanied by an adult responsible for them. Severe conditions such as multiple trauma and traumatic brain injuries resulted from 79% of the accidents. CONCLUSION Falls from roof slabs are accidents of high potential severity, and preventive measures aimed towards informing parents and guardians about the dangers and risk factors associated with this type of accident are needed, along with physical protective measures, such as low walls around the slab and gates with locks to restrict free access to these places.

  2. Accidents due to falls from roof slabs

    Directory of Open Access Journals (Sweden)

    Bruno Alves Rudelli

    Full Text Available CONTEXT AND OBJECTIVE Falls from the roof slabs of houses are accidents of high potential severity that occur in large Brazilian cities and often affect children and adolescents. The aims of this study were to characterize the factors that predispose towards this type of fall involving children and adolescents, quantify the severity of associated lesions and suggest preventive measures. DESIGN AND SETTING Descriptive observational prospective longitudinal study in two hospitals in the metropolitan region of São Paulo. METHODS Data were collected from 29 cases of falls from roof slabs involving children and adolescents between October 2008 and October 2009. RESULTS Cases involving males were more prevalent, accounting for 84%. The predominant age group was schoolchildren (7 to 12 years old; 44%. Leisure activities were most frequently being practiced on the roof slab at the time of the fall (86%, and flying a kite was the most prevalent game (37.9%. In 72% of the cases, the children were unaccompanied by an adult responsible for them. Severe conditions such as multiple trauma and traumatic brain injuries resulted from 79% of the accidents. CONCLUSION Falls from roof slabs are accidents of high potential severity, and preventive measures aimed towards informing parents and guardians about the dangers and risk factors associated with this type of accident are needed, along with physical protective measures, such as low walls around the slab and gates with locks to restrict free access to these places.

  3. Controls and Machine Protection Systems

    CERN Document Server

    Carrone, E.

    2016-01-01

    Machine protection, as part of accelerator control systems, can be managed with a 'functional safety' approach, which takes into account product life cycle, processes, quality, industrial standards and cybersafety. This paper will discuss strategies to manage such complexity and the related risks, with particular attention to fail-safe design and safety integrity levels, software and hardware standards, testing, and verification philosophy. It will also discuss an implementation of a machine protection system at the SLAC National Accelerator Laboratory's Linac Coherent Light Source (LCLS).

  4. Foundations for Protecting Renewable-Rich Distribution Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brahma, Sukumar [New Mexico State Univ., Las Cruces, NM (United States); Ranade, Satish [New Mexico State Univ., Las Cruces, NM (United States)

    2016-11-01

    High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid introduces new challenges to protection of such systems. This is because the existing protection systems are designed with two assumptions: 1) system is single-sourced, resulting in unidirectional fault current, and (2) fault currents are easily detectable due to much higher magnitudes compared to load currents. Due to the fact that most renewables interface with the grid though inverters, and inverters restrict their current output to levels close to the full load currents, both these assumptions are no longer valid - the system becomes multi-sourced, and overcurrent-based protection does not work. The primary scope of this study is to analyze the response of a grid-tied inverter to different faults in the grid, leading to new guidelines on protecting renewable-rich distribution systems.

  5. ADVANCED WORKER PROTECTION SYSTEM

    International Nuclear Information System (INIS)

    Judson Hedgehock

    2001-01-01

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  6. ADVANCED WORKER PROTECTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Judson Hedgehock

    2001-03-16

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  7. Explosion-protected electric heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Elsner, H

    1984-02-01

    Different constructions of explosion-protected heating systems are described concerning the different types of protection, the service conditions, the installation and the surveillance devices. Interpretations and regulations derived from the VDE Standards are discussed and their relation to the European Standards EN 50014 ... 50020 is considered in a survey.

  8. The protection system to Brazilian Nuclear Program

    International Nuclear Information System (INIS)

    Andreuzza, Mario Giussepp Santezzi Bertottelli

    1997-01-01

    The Sistema de Protecao ao Programa Nuclear Brasileiro-SIPRON (Protection System to Brazilian Nuclear Program) was established in 1980. It is intended to accomplish in only one system, all the actions related to security and protection for Nuclear Facilities in Brazil. The author presents in detail the protection system SIPRON, describing the system structure and organization, the functions and obligations of the system involved main organizations, as well as, the system operation and behaviour during an postulated occurrence of a nuclear emergency. It is also described an Exercise that happened in June of 1997 at the Nuclear Power Plant (NPP) Angra I, after two simulated tests in December of 1996 and April of 1997. The NPP Angra I Emergency Plan Exercise was a good opportunity to test the SIPRON structure and preparedness program. It was verified, included by International Atomic Energy Agency observers, the system involved organizations effectiveness and the procedures efficacy to protect the public and the environmental. Finally, it is shown the SIPRON activities of routine, the system obstacles and the expected future performances. (author)

  9. The falls and the fear of falling among elderly institutionalized

    Directory of Open Access Journals (Sweden)

    Patrícia Almeida

    2013-06-01

    Full Text Available In the present study it is intended to characterize the history of falls and to evaluate the fear to fall in aged institutionalized. The sample is composed for 113 institutionalized aged people, 32 men and 81 women with a average 82,96 ± 7,03 age of years. The data had been collected by means of a questionnaire and statistical analyzed (descriptive statistics, parametric tests - Test T and Anova - Test U-Mann Whitney, and Test of Kruskal-Wallis – and the Test of Tukey. The results point in the direction of that the women present a bigger number of falls (24.8% and greater fear to fall (Med=55. The falls had occurred in its majority in the context of the room of the institutions. It was verified that people who had at least a fall experience present greater fear to fall comparatively (Med=55 with that they had not the same had no incident of fall in period of time (Med=77. Our results come to strengthen the hypothesis of the changeable sex to be able to be considered a factor of fall risk. Aged that they present a history of falls seems to be more vulnerable to develop the fear to fall.

  10. Fall prevention in central coast community pharmacies.

    Science.gov (United States)

    Stuart, Gina M; Kale, Helen L

    2018-04-19

    Fall injuries among people aged 65 years and over (older people) cause substantial health decline and cost to the health system. In 2009 in New South Wales, 25.6% of older people fell in the previous year, and 10.7% (32 000) were hospitalised. Pharmacists are trusted professionals, who interact extensively with older people and have potential to augment fall prevention in pharmacies. This brief report describes how professional development improved pharmacist's knowledge and confidence in fall prevention, encouraged implementation of fall prevention plans and facilitated the provision of brief fall prevention interventions for older clients, after identification of fall risk. In 2014, pharmacists from all Central Coast pharmacies (n = 76) were invited to free, continuing professional development (CPD) in fall prevention. It provided education and resources to identify clients' fall risk, conduct brief fall prevention interventions and implement fall prevention health promotion plans (FPHPP). Pharmacists completed written: Baseline and post-workshop questionnaires to assess changes in pharmacist's knowledge and confidence, and existing fall prevention in pharmacies. Logs of client fall risk and brief fall prevention interventions offered to clients. Four-month follow-up questionnaires to assess implementation of FPHPPs and pharmacy practice changes. Pharmacists representing 36% of pharmacies participated. At four-month follow-up, 67% had implemented FPHPPs, and 62% delivered brief interventions determined by client fall risk. Fall prevention in pharmacies can be augmented through locally provided CPD tailored for pharmacists. SO WHAT?: This model could increase fall prevention reach. It is transferable to settings where health professionals provide services to older adults and require reregistration through professional development. © 2018 Australian Health Promotion Association.

  11. Falls efficacy, postural balance, and risk for falls in older adults with falls-related emergency department visits: prospective cohort study.

    Science.gov (United States)

    Pua, Yong-Hao; Ong, Peck-Hoon; Clark, Ross Allan; Matcher, David B; Lim, Edwin Choon-Wyn

    2017-12-21

    Risk for falls in older adults has been associated with falls efficacy (self-perceived confidence in performing daily physical activities) and postural balance, but available evidence is limited and mixed. We examined the interaction between falls efficacy and postural balance and its association with future falls. We also investigated the association between falls efficacy and gait decline. Falls efficacy, measured by the Modified Falls Efficacy Scale (MFES), and standing postural balance, measured using computerized posturography on a balance board, were obtained from 247 older adults with a falls-related emergency department visit. Six-month prospective fall rate and habitual gait speed at 6 months post baseline assessment were also measured. In multivariable proportional odds analyses adjusted for potential confounders, falls efficacy modified the association between postural balance and fall risk (interaction P = 0.014): increasing falls efficacy accentuated the increased fall risk related to poor postural balance. Low baseline falls efficacy was strongly predictive of worse gait speed (0.11 m/s [0.06 to 0.16] slower gait speed per IQR decrease in MFES; P falls efficacy but poor postural balance were at greater risk for falls than those with low falls efficacy; however, low baseline falls efficacy was strongly associated with worse gait function at follow-up. Further research into these subgroups of older adults is warranted. ClinicalTrials.gov identifier: NCT01713543 .

  12. The APS machine protection system (MPS)

    Energy Technology Data Exchange (ETDEWEB)

    Fuja, R.; Berg, B.; Arnold, N. [and others

    1996-08-01

    The machine protection system (MPS) that protects the APS storage ring vacuum chamber from x-ray beams, is active. There are over 650 sensors monitored and networked through the MPS system. About the same number of other process variables are monitored by the much slower EPICS control system, which also has an input to the rf abort chain. The MPS network is still growing with the beam position limits detection system coming on-line. The network configuration, along with a limited description of individual subsystems, is presented.

  13. The APS machine protection system (MPS)

    International Nuclear Information System (INIS)

    Fuja, R.; Berg, B.; Arnold, N.

    1996-01-01

    The machine protection system (MPS) that protects the APS storage ring vacuum chamber from x-ray beams, is active. There are over 650 sensors monitored and networked through the MPS system. About the same number of other process variables are monitored by the much slower EPICS control system, which also has an input to the rf abort chain. The MPS network is still growing with the beam position limits detection system coming on-line. The network configuration, along with a limited description of individual subsystems, is presented

  14. Experimental assessment of an absorption cooling system utilizing a falling film absorber and generator

    International Nuclear Information System (INIS)

    Domínguez-Inzunza, L.A.; Hernández-Magallanes, J.A.; Soto, P.; Jiménez, C.; Gutiérrez-Urueta, G.; Rivera, W.

    2016-01-01

    Highlights: • A new prototype of an absorption cooling system using NH_3/LiNO_3 was developed. • Falling films shell and tubes heat exchangers were used as absorber and generator. • Evaporator temperatures as low as 4 °C were achieved. • The COP varied between 0.27 and 0.62 depending on the system temperatures. • A flow recirculation in the absorber was implemented showing an increase in COP. - Abstract: This study presents the results of the evaluation of an ammonia/lithium nitrate absorption cooling system. The generator and the absorber are shell and tubes falling film heat exchangers while the rest of the components are compact plate heat exchangers. A parametric study was carried out in order to determine the coefficients of performance and cooling capacities at different operating conditions. Also, an analysis was carried out to determine the influence of the absorber solution recirculation on the system performance. The generator temperatures varied between 80 °C and 100 °C, while the cooling water temperatures varied from 20 °C to 34 °C. Cooling capacities up to 4.5 kW and evaporator temperatures as low as 4 °C were achieved with the system. The internal coefficients of performance varied between 0.3 and 0.62 depending on the system operating temperatures. The system also showed good stability and repeatability.

  15. 46 CFR 154.1110 - Areas protected by system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Areas protected by system. 154.1110 Section 154.1110... Firefighting § 154.1110 Areas protected by system. Each water spray system must protect: (a) All cargo tank... valves essential to cargo flow; (f) Each boundary facing the cargo area of each superstructure that...

  16. Dynamic Bayesian Networks for Context-Aware Fall Risk Assessment

    Directory of Open Access Journals (Sweden)

    Gregory Koshmak

    2014-05-01

    Full Text Available Fall incidents among the elderly often occur in the home and can cause serious injuries affecting their independent living. This paper presents an approach where data from wearable sensors integrated in a smart home environment is combined using a dynamic Bayesian network. The smart home environment provides contextual data, obtained from environmental sensors, and contributes to assessing a fall risk probability. The evaluation of the developed system is performed through simulation. Each time step is represented by a single user activity and interacts with a fall sensors located on a mobile device. A posterior probability is calculated for each recognized activity or contextual information. The output of the system provides a total risk assessment of falling given a response from the fall sensor.

  17. Modern thyratron crowbar protection systems

    International Nuclear Information System (INIS)

    Judd, D.A.; Kettle, L.J.; Menown, H.; Newton, B.P.; Nicholls, N.S.; Sheldrake, R.

    1992-01-01

    Two thyratron crowbar systems for high-power klystrons used in linear accelerators are described. The first, contained in an oil filled tank, is a complete system to protect a klystron powered from a 100-kV, 20-A d.c. supply. In the second system a CX1722 glass thyratron, operating in air, has been retrofitted to a test equipment, in place of a spark gap, to protect an Inductive Output Tube (IOT). An important parameter in the choice of the crowbar thyratron is the total coulombs to be switched. Measurements of these follow-on currents are presented. (R.P.) 4 refs.; 10 figs

  18. Standpipe systems for fire protection

    CERN Document Server

    Isman, Kenneth E

    2017-01-01

    This important new manual goes beyond the published NFPA standards on installation of standpipe systems to include the rules in the International Building Code, municipal fire codes, the National Fire Code of Canada, and information on inspection, testing, and maintenance of standpipe systems. Also covered are the interactions between standpipe and sprinkler systems, since these important fire protection systems are so frequently installed together. Illustrated with design examples and practical applications to reinforce the learning experience, this is the go-to reference for engineers, architects, design technicians, building inspectors, fire inspectors, and anyone that inspects, tests or maintains fire protection systems. Fire marshals and plan review authorities that have the responsibility for reviewing and accepting plans and hydraulic calculations for standpipe systems are also an important audience, as are firefighters who actually use standpipe systems. As a member of the committees responsible for s...

  19. Risk and protective factors for falls on one level in young children: multicentre case-control study.

    Science.gov (United States)

    Benford, P; Young, B; Coupland, C; Watson, M; Hindmarch, P; Hayes, M; Goodenough, T; Majsak-Newman, G; Kendrick, D

    2015-12-01

    Childhood falls are an important global public health problem, but there is lack of evidence about their prevention. Falls on one level result in considerable morbidity and they are costly to health services. To estimate ORs for falls on one level in children aged 0-4 years for a range of safety behaviours, safety equipment use and home hazards. Multicentre case-control study at hospitals, minor injury units and general practices in and around four UK study centres. Participants included 582 children less than 5 years of age with a medically attended fall injury occurring at home and 2460 controls matched on age, sex, calendar time and study centre. Fall on one level. Cases' most common injuries were bangs on the head (52%), cuts or grazes not needing stitches (29%) or cuts or grazes needing stitches (17%). Comparing cases to community controls in the adjusted analyses, significant findings were observed for only two exposures. Injured children were significantly less likely to live in a household without furniture corner covers (adjusted OR (AOR) 0.72, 95% CI 0.55 to 0.95), or without rugs and carpets firmly fixed to the floor (AOR 0.76, 95% CI 0.59 to 0.98). We did not find any safety practices, use of safety equipment or home hazards associated with a reduced risk of fall on one level. Our findings do not provide evidence to support changes to current injury prevention practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Aging assessment for active fire protection systems

    International Nuclear Information System (INIS)

    Ross, S.B.; Nowlen, S.P.; Tanaka, T.

    1995-06-01

    This study assessed the impact of aging on the performance and reliability of active fire protection systems including both fixed fire suppression and fixed fire detection systems. The experience base shows that most nuclear power plants have an aggressive maintenance and testing program and are finding degraded fire protection system components before a failure occurs. Also, from the data reviewed it is clear that the risk impact of fire protection system aging is low. However, it is assumed that a more aggressive maintenance and testing program involving preventive diagnostics may reduce the risk impact even further

  1. A New Protection System for Islanding Detection in LV Distribution Systems

    Directory of Open Access Journals (Sweden)

    Anna Rita Di Fazio

    2015-04-01

    Full Text Available The growth of penetration of Distributed Generators (DGs is increasing the risk of unwanted islanded operation in Low Voltage (LV distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match between generation and load. In this paper, a new protection system for islanding detection in LV distribution systems is proposed. The classical voltage and frequency relays in the DG interface protections are enriched with an innovative Smart Islanding Detector, which adopts a new passive islanding detection method. The aim is to keep the advantages of the classical relays while overcoming the problem of their limited sensitivity in detecting balanced islands. In the paper, to define the requirements of the anti-islanding protection system, the events causing the islanded operation of the LV distribution systems are firstly identified and classified. Then, referring to proposed protection system, its architecture and operation are described and, eventually, its performance is analyzed and validated by experimental laboratory tests, carried out with a hardware-in-the-loop technique.

  2. A protection system for picosecond accelerator

    International Nuclear Information System (INIS)

    Cao Hongping; Chinese Academy of Sciences, Beijing; Chen Huanguang; Xu Ruinian; Tang Junlong; Li Deming

    2006-01-01

    A personnel and machine protection system for the picosecond accelerator has been built. The key of the system is to send on/off of three triggering signals which are those of electron gun, 2856 MHz and 476 MHz, respectively, to ensure the safety of users and the accelerator. This paper describes the emergencies interlocked by ADAM5511 and timing trigger processor, and some secondary functions which improve the efficiency of the protection system completed in upper layer software. (authors)

  3. Where attention falls: Increased risk of falls from the converging impact of cortical cholinergic and midbrain dopamine loss on striatal function

    OpenAIRE

    Sarter, Martin; Albin, Roger L.; Kucinski, Aaron; Lustig, Cindy

    2014-01-01

    Falls are a major source of hospitalization, long-term institutionalization, and death in older adults and patients with Parkinson’s disease (PD). Limited attentional resources are a major risk factor for falls. In this review, we specify cognitive–behavioral mechanisms that produce falls and map these mechanisms onto a model of multi-system degeneration. Results from PET studies in PD fallers and findings from a recently developed animal model support the hypothesis that falls result from in...

  4. Changes in step-width during dual-task walking predicts falls.

    Science.gov (United States)

    Nordin, E; Moe-Nilssen, R; Ramnemark, A; Lundin-Olsson, L

    2010-05-01

    The aim was to evaluate whether gait pattern changes between single- and dual-task conditions were associated with risk of falling in older people. Dual-task cost (DTC) of 230 community living, physically independent people, 75 years or older, was determined with an electronic walkway. Participants were followed up each month for 1 year to record falls. Mean and variability measures of gait characteristics for 5 dual-task conditions were compared to single-task walking for each participant. Almost half (48%) of the participants fell at least once during follow-up. Risk of falling increased in individuals where DTC for performing a subtraction task demonstrated change in mean step-width compared to single-task walking. Risk of falling decreased in individuals where DTC for carrying a cup and saucer demonstrated change compared to single-task walking in mean step-width, mean step-time, and step-length variability. Degree of change in gait characteristics related to a change in risk of falling differed between measures. Prognostic guidance for fall risk was found for the above DTCs in mean step-width with a negative likelihood ratio of 0.5 and a positive likelihood ratio of 2.3, respectively. Findings suggest that changes in step-width, step-time, and step-length with dual tasking may be related to future risk of falling. Depending on the nature of the second task, DTC may indicate either an increased risk of falling, or a protective strategy to avoid falling. Copyright 2010. Published by Elsevier B.V.

  5. Advanced worker protection system

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, B.; Duncan, P.; Myers, J. [Oceaneering Space Systems, Houston, TX (United States)

    1995-10-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment.

  6. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment

  7. Fall Risk Assessment and Early-Warning for Toddler Behaviors at Home

    Directory of Open Access Journals (Sweden)

    Mau-Tsuen Yang

    2013-12-01

    Full Text Available Accidental falls are the major cause of serious injuries in toddlers, with most of these falls happening at home. Instead of providing immediate fall detection based on short-term observations, this paper proposes an early-warning childcare system to monitor fall-prone behaviors of toddlers at home. Using 3D human skeleton tracking and floor plane detection based on depth images captured by a Kinect system, eight fall-prone behavioral modules of toddlers are developed and organized according to four essential criteria: posture, motion, balance, and altitude. The final fall risk assessment is generated by a multi-modal fusion using either a weighted mean thresholding or a support vector machine (SVM classification. Optimizations are performed to determine local parameter in each module and global parameters of the multi-modal fusion. Experimental results show that the proposed system can assess fall risks and trigger alarms with an accuracy rate of 92% at a speed of 20 frames per second.

  8. Fall Risk Assessment and Early-Warning for Toddler Behaviors at Home

    Science.gov (United States)

    Yang, Mau-Tsuen; Chuang, Min-Wen

    2013-01-01

    Accidental falls are the major cause of serious injuries in toddlers, with most of these falls happening at home. Instead of providing immediate fall detection based on short-term observations, this paper proposes an early-warning childcare system to monitor fall-prone behaviors of toddlers at home. Using 3D human skeleton tracking and floor plane detection based on depth images captured by a Kinect system, eight fall-prone behavioral modules of toddlers are developed and organized according to four essential criteria: posture, motion, balance, and altitude. The final fall risk assessment is generated by a multi-modal fusion using either a weighted mean thresholding or a support vector machine (SVM) classification. Optimizations are performed to determine local parameter in each module and global parameters of the multi-modal fusion. Experimental results show that the proposed system can assess fall risks and trigger alarms with an accuracy rate of 92% at a speed of 20 frames per second. PMID:24335727

  9. Fall risk assessment and early-warning for toddler behaviors at home.

    Science.gov (United States)

    Yang, Mau-Tsuen; Chuang, Min-Wen

    2013-12-10

    Accidental falls are the major cause of serious injuries in toddlers, with most of these falls happening at home. Instead of providing immediate fall detection based on short-term observations, this paper proposes an early-warning childcare system to monitor fall-prone behaviors of toddlers at home. Using 3D human skeleton tracking and floor plane detection based on depth images captured by a Kinect system, eight fall-prone behavioral modules of toddlers are developed and organized according to four essential criteria: posture, motion, balance, and altitude. The final fall risk assessment is generated by a multi-modal fusion using either a weighted mean thresholding or a support vector machine (SVM) classification. Optimizations are performed to determine local parameter in each module and global parameters of the multi-modal fusion. Experimental results show that the proposed system can assess fall risks and trigger alarms with an accuracy rate of 92% at a speed of 20 frames per second.

  10. Association between patient unconscious or not alert conditions and cardiac arrest or high-acuity outcomes within the Medical Priority Dispatch System "Falls" protocol.

    Science.gov (United States)

    Clawson, Jeff; Olola, Christopher; Scott, Greg; Schultz, Bryon; Pertgen, Richard; Robinson, Don; Bagwell, Barry; Patterson, Brett

    2010-01-01

    Falls are one of the most common types of complaints received by 9-1-1 emergency medical dispatch centers. They can be accidental or may be caused by underlying medical problems. Though "not alert" falls patients with severe outcomes mostly are "hot" transported to the hospital, some of these cases may be due to other acute medical events (cardiac, respiratory, circulatory, or neurological), which may not always be apparent to the emergency medical dispatcher (EMD) during call processing. The objective of this study was to characterize the risk of cardiac arrest and "hot-transport" outcomes in patients with "not alert" condition, within the Medical Priority Dispatch System (MPDS®) Falls protocol descriptors. This retrospective study used 129 months of de-identified, aggregate, dispatch datasets from three US emergency communication centers. The communication centers used the Medical Priority Dispatch System version 11.3-OMEGA type (released in 2006) to interrogate Emergency Medical System callers, select dispatch codes assigned to various response configurations, and provide pre-arrival instructions. The distribution of cases and percentages of cardiac arrest and hot-transport outcomes, categorized by MPDS® code, was profiled. Assessment of the association between MPDS® Delta-level 3 (D-3) "not alert" condition and cardiac arrest and hot-transport outcomes then followed. Overall, patients within the D-3 and D-2 "long fall" conditions had the highest proportions (compared to the other determinants in the "falls" protocol) of cardiac arrest and hot-transport outcomes, respectively. "Not alert" condition was associated significantly with cardiac arrest and hot-transport outcomes (pdeterminant within the MPDS® "fall" protocol was associated significantly with severe outcomes for short falls (falls. As reported to 9-1-1, the complaint of a "fall" may include the presence of underlying conditions that go beyond the obvious traumatic injuries caused by the fall itself.

  11. Detection and Prevention of Seniors Falls

    Directory of Open Access Journals (Sweden)

    Lubomír MACKŮ

    2016-11-01

    Full Text Available The paper deals with the issue of seniors’ security and safety, namely the security problems related to falls of independently living elderly citizens. The number of elderly people is growing very fast worldwide and very often they live unattended in their house or flat. In case of accidently falling down, they are often unable help themselves and stay on the floor for hours or even longer. This may lead even to the death if no help comes. Various possibilities of their fall detection are studied. We analyze the historical development, current capabilities and efficiency of different approaches and methods. We address the willingness and ability of seniors to actively use technology, detection limits, privacy, personal data security and other important factors. In addition, we discuss the challenges, current shortcomings, issues and trends in fall detection or operation reliability in real-life conditions. The main future goal would be to maintain the personal privacy and security of irrelevant information in modern fall detection systems.

  12. The Philosophy of the New Radiation Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Wikman, P.

    2004-07-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle ''If the individual is sufficiently protected from a source, then society is also protected from that source''. This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs.

  13. The Philosophy of the New Radiation Protection System

    International Nuclear Information System (INIS)

    Wikman, P.

    2004-01-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle I f the individual is sufficiently protected from a source, then society is also protected from that source . This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs

  14. Optimal fall indicators for slip induced falls on a cross-slope.

    Science.gov (United States)

    Domone, Sarah; Lawrence, Daniel; Heller, Ben; Hendra, Tim; Mawson, Sue; Wheat, Jonathan

    2016-08-01

    Slip-induced falls are among the most common cause of major occupational injuries in the UK as well as being a major public health concern in the elderly population. This study aimed to determine the optimal fall indicators for fall detection models which could be used to reduce the detrimental consequences of falls. A total of 264 kinematic variables covering three-dimensional full body model translation and rotational measures were analysed during normal walking, successful recovery from slips and falls on a cross-slope. Large effect sizes were found for three kinematic variables which were able to distinguish falls from normal walking and successful recovery. Further work should consider other types of daily living activities as results show that the optimal kinematic fall indicators can vary considerably between movement types. Practitioner Summary: Fall detection models are used to minimise the adverse consequences of slip-induced falls, a major public health concern. Optimal fall indicators were derived from a comprehensive set of kinematic variables for slips on a cross-slope. Results suggest robust detection of falls is possible on a cross-slope but may be more difficult than level walking.

  15. Exploration and Implementation of a Pre-Impact Fall Recognition Method Based on an Inertial Body Sensor Network

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2012-11-01

    Full Text Available The unintentional injuries due to falls in elderly people give rise to a multitude of health and economic problems due to the growing aging population. The use of early pre-impact fall alarm and self-protective control could greatly reduce fall injuries. This paper aimed to explore and implement a pre-impact fall recognition/alarm method for free-direction fall activities based on understanding of the pre-impact lead time of falls and the angle of body postural stability using an inertial body sensor network. Eight healthy Asian adult subjects were arranged to perform three kinds of daily living activities and three kinds of fall activities. Nine MTx sensor modules were used to measure the body segmental kinematic characteristics of each subject for pre-impact fall recognition/alarm. Our analysis of the kinematic features of human body segments showed that the chest was the optimal sensor placement for an early pre-impact recognition/alarm (i.e., prediction/alarm of a fall event before it happens and post-fall detection (i.e., detection of a fall event after it already happened. Furthermore, by comparative analysis of threshold levels for acceleration and angular rate, two acceleration thresholds were determined for early pre-impact alarm (7 m/s/s and post-fall detection (20 m/s/s under experimental conditions. The critical angles of postural stability of torso segment in three kinds of fall activities (forward, sideway and backward fall were determined as 23.9 ± 3.3, 49.9 ± 4.1 and 9.9 ± 2.5 degrees, respectively, and the relative average pre-impact lead times were 329 ± 21, 265 ± 35 and 257 ± 36 ms. The results implied that among the three fall activities the sideway fall was associated with the largest postural stability angle and the forward fall was associated with the longest time to adjust body angle to avoid the fall; the backward fall was the most difficult to avoid among the three kinds of fall events due to the toughest

  16. A Piece of Paper Falling Faster than Free Fall

    Science.gov (United States)

    Vera, F.; Rivera, R.

    2011-01-01

    We report a simple experiment that clearly demonstrates a common error in the explanation of the classic experiment where a small piece of paper is put over a book and the system is let fall. This classic demonstration is used in introductory physics courses to show that after eliminating the friction force with the air, the piece of paper falls…

  17. Televison assessment and identification system for the plutonium protection system

    International Nuclear Information System (INIS)

    Greenwoll, D.A.

    1979-02-01

    This report covers the selection, description, and use of the components comprising the Television Assessment and Identification System in the Hanford Plutonium Protection System. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Facility Physical Protection Program

  18. Establishing an Information Security System related to Physical Protection

    International Nuclear Information System (INIS)

    Jang, Sung Soon; Yoo, Ho Sik

    2009-01-01

    A physical protection system (PPS) integrates people, procedures and equipment for the protection of assets or facilities against theft, sabotage or other malevolent attacks. In the physical protection field, it is important the maintain confidentiality of PPS related information, such as the alarm system layout, detailed maps of buildings, and guard schedules. In this abstract, we suggest establishing a methodology for an information security system. The first step in this methodology is to determine the information to protect and possible adversaries. Next, system designers should draw all possible paths to the information and arrange appropriate protection elements. Finally he/she should analyze and upgrade their information security system

  19. Designing and evaluating an electronic patient falls reporting system: perspectives for the implementation of health information technology in long-term residential care facilities.

    Science.gov (United States)

    Mei, Yi You; Marquard, Jenna; Jacelon, Cynthia; DeFeo, Audrey L

    2013-11-01

    Patient falls are the leading cause of unintentional injury and death among older adults. In 2000, falls resulted in over 10,300 elderly deaths, costing the United States approximately $179 million in incidence and medical costs. Furthermore, non-fatal injuries caused by falls cost the United States $19 billion annually. Health information technology (IT) applications, specifically electronic falls reporting systems, can aid quality improvement efforts to prevent patient falls. Yet, long-term residential care facilities (LTRCFs) often do not have the financial resources to implement health IT, and workers in these settings are often not ready to adopt such systems. Additionally, most health IT evaluations are conducted in large acute-care settings, so LTRCF administrators currently lack evidence to support the value of health IT. In this paper, we detail the development of a novel, easy-to-use system to facilitate electronic patient falls reporting within a LTRCF using off-the-shelf technology that can be inexpensively implemented in a wide variety of settings. We report the results of four complimentary system evaluation measures that take into consideration varied organizational stakeholders' perspectives: (1) System-level benefits and costs, (2) system usability, via scenario-based use cases, (3) a holistic assessment of users' physical, cognitive, and marcoergonomic (work system) challenges in using the system, and (4) user technology acceptance. We report the viability of collecting and analyzing data specific to each evaluation measure and detail the relative merits of each measure in judging whether the system is acceptable to each stakeholder. The electronic falls reporting system was successfully implemented, with 100% reporting at 3-months post-implementation. The system-level benefits and costs approach showed that the electronic system required no initial investment costs aside from personnel costs and significant benefits accrued from user time savings

  20. Machine Protection System response in 2011

    CERN Document Server

    Zerlauth, M; Wenninger, J

    2012-01-01

    The performance of the machine protection system during the 2011 run is summarized in this paper. Following an analysis of the beam dump causes in comparison to the previous 2010 run, special emphasis will be given to analyse events which risked to exposed parts of the machine to damage. Further improvements and mitigations of potential holes in the protection systems as well as in the change management will be evaluated along with their impact on the 2012 run. The role of the restricted Machine Protection Panel ( rMPP ) during the various operational phases such as commissioning, the intensity ramp up and Machine Developments is being discussed.

  1. Prevalence of fall injuries and risk factors for fall among hospitalized children in a specialized childrens hospital in Saudi Arabia.

    Science.gov (United States)

    AlSowailmi, Banan Abdullah; AlAkeely, Maha Heshaam; AlJutaily, Hayat Ibrahim; Alhasoon, Mohammad Abdulaziz; Omair, Amir; AlKhalaf, Hamad Abdullah

    2018-01-01

    Fall injuries among children during hospital stay is a major patient safety issue. Inpatient pediatric falls can lead to numerous negative consequences. In contrast to adults, there is a paucity of information on the prevalence and risk factors associated with children's falls during hospitalization. Identify the prevalence of fall injuries among hospital.ized children and describe the demographic and environmental factors that could predict a higher risk of severe outcomes of fall. Descriptive, cross-sectional prevalence study. Specialized children's hospital. Data was obtained through the electronic Safety Reporting System (SRS). All reported fall events during hospitalization in children less than or equal 14 years of age for the period from 1 April 2015 to 30 April 2016 were included. Fall events that occurred in the day care unit and the outpatient clinic were excluded. Prevalence and possible risk factors for fall events. 48. The prevalence of falls among the 4860 admitted children was 9.9 (95% CI=7.5, 13.1) per 1000 patients (48/4860). A majority of the falls were among boys (n=26, 54%), in the age group from 1-5 years old (n=22, 46%), in children at high risk of falling (n=35, 73%), with normal mobility status (n=21, 44%), and with no history of previ.ous falls (n=33, 69%). Severe injuries accounted for 25% of falls (n=12). However, falls among the moderate risk category (n=9, 69%) were more often severe than falls among the high risk category of children (n=12, 34%) (P=.03). Risk factor identification is required to prevent falls and their severe outcomes. Underreporting and single-centered study. None.

  2. Increasing fall risk awareness using wearables: A fall risk awareness protocol.

    Science.gov (United States)

    Danielsen, Asbjørn; Olofsen, Hans; Bremdal, Bernt Arild

    2016-10-01

    Each year about a third of elderly aged 65 or older experience a fall. Many of these falls may have been avoided if fall risk assessment and prevention tools where available in a daily living situation. We identify what kind of information is relevant for doing fall risk assessment and prevention using wearable sensors in a daily living environment by investigating current research, distinguishing between prospective and context-aware fall risk assessment and prevention. Based on our findings, we propose a fall risk awareness protocol as a fall prevention tool integrating both wearables and ambient sensing technology into a single platform. Copyright © 2016. Published by Elsevier Inc.

  3. Relationship between subjective fall risk assessment and falls and fall-related fractures in frail elderly people

    OpenAIRE

    Shimada, Hiroyuki; Suzukawa, Megumi; Ishizaki, Tatsuro; Kobayashi, Kumiko; Kim, Hunkyung; Suzuki, Takao

    2011-01-01

    Abstract Background Objective measurements can be used to identify people with risks of falls, but many frail elderly adults cannot complete physical performance tests. The study examined the relationship between a subjective risk rating of specific tasks (SRRST) to screen for fall risks and falls and fall-related fractures in frail elderly people. Methods The SRRST was investigated in 5,062 individuals aged 65 years or older who were utilized day-care services. The SRRST comprised 7 dichotom...

  4. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1979-01-01

    An absorber element blow-out protection system for a nuclear reactor having a pressure vessel through which a coolant is circulated. The blow-out protection system includes devices which hydraulically couple groups of guide tubes in which the absorber elements move, the coupling devices limiting coolant lift flow rate to a level commensurate with the raising of individual absorber elements but insufficient to raise a plurality of absorber elements simultaneously

  5. Evaluation of several corrosion protective coating systems on aluminum

    Science.gov (United States)

    Higgins, R. H.

    1981-01-01

    A study of several protective coating systems for use on aluminum in seawater/seacoast environments was conducted to review the developments made on protective coatings since early in the Space Shuttle program and to perform comparative studies on these coatings to determine their effectiveness for providing corrosion protection during exposure to seawater/seacoast environments. Panels of 2219-T87 aluminum were coated with 21 different systems and exposed to a 5 percent salt spray for 4000 hr. Application properties, adhesion measurements, heat resistance and corrosion protection were evaluated. For comparative studies, the presently specified Bostik epoxy system used on the SRB structures was included. Results of these tests indicate four systems with outstanding performance and four additional systems with protection almost as good. These systems are based on a chromated pretreatment, a chromate epoxy primer, and a polyurethane topcoat. Consideration for one of these systems should be included for those applications where superior corrosion protection for aluminum surfaces is required.

  6. Incipient fault detection and power system protection for spaceborne systems

    Science.gov (United States)

    Russell, B. Don; Hackler, Irene M.

    1987-01-01

    A program was initiated to study the feasibility of using advanced terrestrial power system protection techniques for spacecraft power systems. It was designed to enhance and automate spacecraft power distribution systems in the areas of safety, reliability and maintenance. The proposed power management/distribution system is described as well as security assessment and control, incipient and low current fault detection, and the proposed spaceborne protection system. It is noted that the intelligent remote power controller permits the implementation of digital relaying algorithms with both adaptive and programmable characteristics.

  7. The information protection level assessment system implementation

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    Currently, the threat of various attacks increases significantly as automated systems become more widespread. On the basis of the conducted analysis the information protection level assessment system establishing objective was identified. The paper presents the information protection level assessment software implementation in the information system by applying the programming language C #. In conclusions the software features are identified and experimental results are represented.

  8. The clinical practice guideline for falls and fall risk

    OpenAIRE

    Vance, Jacqueline

    2011-01-01

    Falling is a significant cause of injury and death in frail older adults. Residents in long-term care (LTC) facilities fall for a variety of reasons and are more likely to endure injuries after a fall than those in the community The American Medical Directors Association (AMDA) Clinical Practice Guideline is written to give LTC staff an understanding of risk factors for falls and provide guidance for a systematic approach to patient assessment and selection of appropriate interventions. It is...

  9. Temporal association between hospitalization and rate of falls after discharge.

    Science.gov (United States)

    Mahoney, J E; Palta, M; Johnson, J; Jalaluddin, M; Gray, S; Park, S; Sager, M

    2000-10-09

    Evidence suggests that acute illness and hospitalization may increase the risk for falls. To evaluate the rate of falls, and associated risk factors, for 90 days following hospital discharge. We consecutively enrolled 311 patients, aged 65 years and older, discharged from the hospital after an acute medical illness and receiving home-nursing services. Patients were assessed within 5 days of discharge for prehospital and current functioning by self-report, and balance, vision, cognition, and delirium by objective measures. Patients were followed up weekly for 13 weeks for falls, injuries, and health care use. The rate of falls was significantly higher in the first 2 weeks after hospitalization (8.0 per 1000 person-days) compared with 3 months later (1.7 per 1000 person-days) (P =.002). Fall-related injuries accounted for 15% of all hospitalizations in the first month after discharge. Independent prehospital risk factors significantly associated with falls included dependency in activities of daily living, use of a standard walker, 2 or more falls, and more hospitalizations in the year prior. Posthospital risk factors included use of a tertiary amine tricyclic antidepressant, probable delirium, and poorer balance, while use of a cane was protective. The rate of falls is substantially increased in the first month after medical hospitalization, and is an important cause of injury and morbidity. Posthospital risk factors may be potentially modifiable. Efforts to assess and modify risk factors should be integral to the hospital and posthospital care of older adults (those aged >/=65 years).

  10. Annexes to the lecture on reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The present paper deals with the fundamentals for a reactor protection system and discusses the following topics: - System lay-out - Analog measured data acquisition - Analog measured data processing - Limit value generation and logical gating - Procesing of the reactor protection actuation signals - Decoupling of the reactor protection system - Mechanical lay-out - Monitoring system and - Emergency control station. (orig./RW)

  11. Operational test report - Project W-320 cathodic protection systems

    International Nuclear Information System (INIS)

    Bowman, T.J.

    1998-01-01

    Washington Administrative Code (WAC) 173-303-640 specifies that corrosion protection must be designed into tank systems that treat or store dangerous wastes. Project W-320, Waste Retrieval Sluicing System (WRSS), utilizes underground encased waste transfer piping between tanks 241-C-106 and 241-AY-102. Corrosion protection is afforded to the encasements of the WRSS waste transfer piping through the application of earthen ionic currents onto the surface of the piping encasements. Cathodic protection is used in conjunction with the protective coatings that are applied upon the WRSS encasement piping. WRSS installed two new two rectifier systems (46 and 47) and modified one rectifier system (31). WAC 173-303-640 specifies that the proper operation of cathodic protection systems must be confirmed within six months after initial installation. The WRSS cathodic protection systems were energized to begin continuous operation on 5/5/98. Sixteen days after the initial steady-state start-up of the WRSS rectifier systems, the operational testing was accomplished with procedure OTP-320-006 Rev/Mod A-0. This operational test report documents the OTP-320-006 results and documents the results of configuration testing of integrated piping and rectifier systems associated with the W-320 cathodic protection systems

  12. Validation of reactor core protection system

    International Nuclear Information System (INIS)

    Lee, Sang-Hoon; Bae, Jong-Sik; Baeg, Seung-Yeob; Cho, Chang-Ho; Kim, Chang-Ho; Kim, Sung-Ho; Kim, Hang-Bae; In, Wang-Kee; Park, Young-Ho

    2008-01-01

    Reactor COre Protection System (RCOPS), an advanced core protection calculator system, is a digitized one which provides core protection function based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels adapted a two-out-of-four trip logic. System configuration, hardware platform and an improved algorithm of the newly designed core protection calculator system are described in this paper. One channel of RCOPS was implemented as a single channel facility for this R and D project where we performed final integration software testing. To implement custom function blocks, pSET is used. Software test is performed by two methods. The first method is a 'Software Module Test' and the second method is a 'Software Unit Test'. New features include improvement of core thermal margin through a revised on-line DNBR algorithm, resolution of the latching problem of control element assembly signal and addition of the pre-trip alarm generation. The change of the on-line DNBR calculation algorithm is considered to improve the DNBR net margin by 2.5%-3.3%. (author)

  13. Analysis of Android Device-Based Solutions for Fall Detection

    Directory of Open Access Journals (Sweden)

    Eduardo Casilari

    2015-07-01

    Full Text Available Falls are a major cause of health and psychological problems as well as hospitalization costs among older adults. Thus, the investigation on automatic Fall Detection Systems (FDSs has received special attention from the research community during the last decade. In this area, the widespread popularity, decreasing price, computing capabilities, built-in sensors and multiplicity of wireless interfaces of Android-based devices (especially smartphones have fostered the adoption of this technology to deploy wearable and inexpensive architectures for fall detection. This paper presents a critical and thorough analysis of those existing fall detection systems that are based on Android devices. The review systematically classifies and compares the proposals of the literature taking into account different criteria such as the system architecture, the employed sensors, the detection algorithm or the response in case of a fall alarms. The study emphasizes the analysis of the evaluation methods that are employed to assess the effectiveness of the detection process. The review reveals the complete lack of a reference framework to validate and compare the proposals. In addition, the study also shows that most research works do not evaluate the actual applicability of the Android devices (with limited battery and computing resources to fall detection solutions.

  14. Analysis of Android Device-Based Solutions for Fall Detection.

    Science.gov (United States)

    Casilari, Eduardo; Luque, Rafael; Morón, María-José

    2015-07-23

    Falls are a major cause of health and psychological problems as well as hospitalization costs among older adults. Thus, the investigation on automatic Fall Detection Systems (FDSs) has received special attention from the research community during the last decade. In this area, the widespread popularity, decreasing price, computing capabilities, built-in sensors and multiplicity of wireless interfaces of Android-based devices (especially smartphones) have fostered the adoption of this technology to deploy wearable and inexpensive architectures for fall detection. This paper presents a critical and thorough analysis of those existing fall detection systems that are based on Android devices. The review systematically classifies and compares the proposals of the literature taking into account different criteria such as the system architecture, the employed sensors, the detection algorithm or the response in case of a fall alarms. The study emphasizes the analysis of the evaluation methods that are employed to assess the effectiveness of the detection process. The review reveals the complete lack of a reference framework to validate and compare the proposals. In addition, the study also shows that most research works do not evaluate the actual applicability of the Android devices (with limited battery and computing resources) to fall detection solutions.

  15. Analysis of Android Device-Based Solutions for Fall Detection

    Science.gov (United States)

    Casilari, Eduardo; Luque, Rafael; Morón, María-José

    2015-01-01

    Falls are a major cause of health and psychological problems as well as hospitalization costs among older adults. Thus, the investigation on automatic Fall Detection Systems (FDSs) has received special attention from the research community during the last decade. In this area, the widespread popularity, decreasing price, computing capabilities, built-in sensors and multiplicity of wireless interfaces of Android-based devices (especially smartphones) have fostered the adoption of this technology to deploy wearable and inexpensive architectures for fall detection. This paper presents a critical and thorough analysis of those existing fall detection systems that are based on Android devices. The review systematically classifies and compares the proposals of the literature taking into account different criteria such as the system architecture, the employed sensors, the detection algorithm or the response in case of a fall alarms. The study emphasizes the analysis of the evaluation methods that are employed to assess the effectiveness of the detection process. The review reveals the complete lack of a reference framework to validate and compare the proposals. In addition, the study also shows that most research works do not evaluate the actual applicability of the Android devices (with limited battery and computing resources) to fall detection solutions. PMID:26213928

  16. Electrical Power Systems Protection and Interdependencies with ICT

    OpenAIRE

    Milis, George; Kyriakides, Elias; Hadjiantonis, Antonis

    2017-01-01

    The present chapter discusses the issue of protection of the electrical power systems, addressing all dimensions, from the need of protection to the identified faults and disturbances to the available protection schemes and further considerations, also looking at the challenges brought by recognizing the interdependent nature of the today’s electrical power systems.

  17. Prediction of falls and/or near falls in people with mild Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Beata Lindholm

    Full Text Available To determine factors associated with future falls and/or near falls in people with mild PD.The study included 141 participants with PD. Mean (SD age and PD-duration were 68 (9.7 and 4 years (3.9, respectively. Their median (q1-q3 UPDRS III score was 13 (8-18. Those >80 years of age, requiring support in standing or unable to understand instructions were excluded. Self-administered questionnaires targeted freezing of gait, turning hesitations, walking difficulties in daily life, fatigue, fear of falling, independence in activities of daily living, dyskinesia, demographics, falls/near falls history, balance problems while dual tasking and pain. Clinical assessments addressed functional balance performance, retropulsion, comfortable gait speed, motor symptoms and cognition. All falls and near falls were subsequently registered in a diary during a six-month period. Risk factors for prospective falls and/or near falls were determined using logistic regression.Sixty-three participants (45% experienced ≥ 1 fall and/or near fall. Three factors were independent predictors of falls and/or near falls: fear of falling (OR = 1.032, p<0.001 history of near falls (OR = 3.475, p = 0.009 and retropulsion (OR = 2.813, p = 0.035. The strongest contributing factor was fear of falling, followed by a history of near falls and retropulsion.Fear of falling seems to be an important issue to address already in mild PD as well as asking about prior near falls.

  18. Fire protection in ventilation systems and in case of fire operating ventilation systems

    International Nuclear Information System (INIS)

    Zitzelsberger, J.

    1983-01-01

    The fire risks in ventilation systems are discussed. It follows a survey of regulations on fire prevention and fire protection in ventilation systems and smoke and heat exhaust systems applicable to nuclear installations in the Federal Republic of Germany. Fire protection concepts for normal systems and for systems operating also in case of fire will be given. Several structural elements for fire protection in those systems will be illustrated with regard to recent research findings

  19. Angle Control-Based Multi-Terminal Out-of-Step Protection System

    OpenAIRE

    Antans Sauhats; Andrejs Utans; Dmitrijs Antonovs; Andrejs Svalovs

    2017-01-01

    From time to time a sequence of unexpected and overlapping contingencies may lead to power system angular instability and even blackouts if not addressed adequately by means of an out-of-step (OOS) protection system. The motivation of the paper is an attempt to develop a workable prototype of the OOS protection system. The deficiencies of the protection currently used in the Latvian Power System network are highlighted and a new protection structure is proposed. The protection system comprise...

  20. DLP-systems: Protection from Insiders

    Directory of Open Access Journals (Sweden)

    Ivan Sergeevich Boridko

    2013-02-01

    Full Text Available In the paper the necessity of further introduction of modern systems of information protection against internal leaks, including DLP-systems, is justified. The issues of development of training specialists in the field of information security is considered.

  1. 14 CFR 25.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 25.954...

  2. 14 CFR 27.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 27.954...

  3. 14 CFR 29.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 29.954...

  4. 14 CFR 23.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 23.954... Fuel System § 23.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a...

  5. Unexplained Falls Are Frequent in Patients with Fall-Related Injury Admitted to Orthopaedic Wards: The UFO Study (Unexplained Falls in Older Patients).

    Science.gov (United States)

    Chiara, Mussi; Gianluigi, Galizia; Pasquale, Abete; Alessandro, Morrione; Alice, Maraviglia; Gabriele, Noro; Paolo, Cavagnaro; Loredana, Ghirelli; Giovanni, Tava; Franco, Rengo; Giulio, Masotti; Gianfranco, Salvioli; Niccolò, Marchionni; Andrea, Ungar

    2013-01-01

    To evaluate the incidence of unexplained falls in elderly patients affected by fall-related fractures admitted to orthopaedic wards, we recruited 246 consecutive patients older than 65 (mean age 82 ± 7 years, range 65-101). Falls were defined "accidental" (fall explained by a definite accidental cause), "medical" (fall caused directly by a specific medical disease), "dementia-related" (fall in patients affected by moderate-severe dementia), and "unexplained" (nonaccidental falls, not related to a clear medical or drug-induced cause or with no apparent cause). According to the anamnestic features of the event, older patients had a lower tendency to remember the fall. Patients with accidental fall remember more often the event. Unexplained falls were frequent in both groups of age. Accidental falls were more frequent in younger patients, while dementia-related falls were more common in the older ones. Patients with unexplained falls showed a higher number of depressive symptoms. In a multivariate analysis a higher GDS and syncopal spells were independent predictors of unexplained falls. In conclusion, more than one third of all falls in patients hospitalized in orthopaedic wards were unexplained, particularly in patients with depressive symptoms and syncopal spells. The identification of fall causes must be evaluated in older patients with a fall-related injury.

  6. Advanced nuclear control and protection system ANCAP-80

    International Nuclear Information System (INIS)

    Asai, Takashi; Okano, Michihiko; Ishibashi, Kengo; Hasegawa, Masakoto; Fukuda, Hiroyoshi; Hosomichi, Renichi.

    1983-01-01

    Advanced reactor protection systems were developed to improve operational reliability and availability and to ease the burden of operators of Mitsubishi PWR Nuclear Power Stations. (Called ANCAP-80; Advanced Nuclear Control And Protection System) For the PWR plants now being planned and in future plans, Mitsubishi will adopt these systems with the following functional features; (1) Four channel protection logic, (2) Automatic bypass logic, (3) Automatic test provision, (4) Optical isolators. (author)

  7. A protection system of low temperature thermo-supply nuclear reactor

    International Nuclear Information System (INIS)

    Jiang Binsen

    1988-09-01

    A Protection system of low temperature thermo-supply nuclear reactor is introduced. It is the first protection system, which is designed and manufactred on the basis of Chinese National Standard GB 4083-83 'General Safety Principle of Nuclear Reactor Protection System', to be considered under the circumstances of industry level in China. Advantages of the protection system are as follows: 1)The single failure criteria can fully be fulfilled by the protection system. 2) On-line testing system can be used for detecting all of failure components and quick identifying the failure points in the system. 3) It is convenience for maintenacnce of the system. To complete this project is very important and helpful in promoting the development of the protection system and safety operation of nuclear reactor in China

  8. Reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The safety concept requires to ensure that - the reactor protection system - the active engineered safeguard - and the necessary auxiliary systems are so designed and interfaced in respect of design and mode of action that, in the event of single component failure reliable control of the consequences of accidents remains ensured at all times and that the availability of the power plant is not limited unnecessarily. In order to satisfy these requirements due, importance was attached to a consistent spacial separation of the mutually redundant subsystems of the active safety equipment. The design and layout of the reactor protection system, of the power supply (emergency power supply), and of the auxiliary systems important from the safety engineering point of view, are such that their subsystems also largely satisfy the requirements of independence and spacial separation. (orig./RW)

  9. Where attention falls: Increased risk of falls from the converging impact of cortical cholinergic and midbrain dopamine loss on striatal function

    Science.gov (United States)

    Sarter, Martin; Albin, Roger L.; Kucinski, Aaron; Lustig, Cindy

    2015-01-01

    Falls are a major source of hospitalization, long-term institutionalization, and death in older adults and patients with Parkinson’s disease (PD). Limited attentional resources are a major risk factor for falls. In this review, we specify cognitive–behavioral mechanisms that produce falls and map these mechanisms onto a model of multi-system degeneration. Results from PET studies in PD fallers and findings from a recently developed animal model support the hypothesis that falls result from interactions between loss of basal forebrain cholinergic projections to the cortex and striatal dopamine loss. Striatal dopamine loss produces inefficient, low-vigor gait, posture control, and movement. Cortical cholinergic deafferentation impairs a wide range of attentional processes, including monitoring of gait, posture and complex movements. Cholinergic cell loss reveals the full impact of striatal dopamine loss on motor performance, reflecting loss of compensatory attentional supervision of movement. Dysregulation of dorsomedial striatal circuitry is an essential, albeit not exclusive, mediator of falls in this dual-system model. Because cholinergic neuromodulatory activity influences cortical circuitry primarily via stimulation of α4β2* nicotinic acetylcholine receptors, and because agonists at these receptors are known to benefit attentional processes in animals and humans, treating PD fallers with such agonists, as an adjunct to dopaminergic treatment, is predicted to reduce falls. Falls are an informative behavioral endpoint to study attentional–motor integration by striatal circuitry. PMID:24805070

  10. Programmed system for nuclear power plant protection

    International Nuclear Information System (INIS)

    Jover, Pierre.

    1980-06-01

    The progress in the field of microprocessors and large scale integration circuits, have incited to introduce this new technologies into nuclear power plant protection system. The hardware and software design principles are briefly listed; then, a quad-redundant protection system for 1300 MWe PWR, developed in France is described [fr

  11. Influences of a Church-Based Intervention on Falls Risk Among Seniors.

    Science.gov (United States)

    Briggs, Morgan; Morzinski, Jeffrey A; Ellis, Julie

    2017-08-01

    Prior studies illustrate that community-based programs effectively decrease falls risk in older adults and that faith-based programs improve health behaviors. The literature is unclear whether faith-based initiatives reduce seniors' fall risks. To tackle this gap, a long-term partnership led by 10 urban churches, a nearby nursing school, and a medical school developed a study with 3 objectives: determine baseline health concerns associated with falls (eg, depression, polypharmacy), implement a nurse-led, faith-based health education initiative for community-dwelling African American seniors at-risk of hospitalization, and assess pre- to post -program fall frequency. The 100 Healthy, At-Risk Families study team implemented 8 monthly educational health sessions promoting self-care and social support. Community nurses led the 60- to 90-minute sessions at each of 10 churches. To collect study data, nurses interviewed enrolled seniors pre- and post-intervention. Descriptive and comparison statistics were analyzed in Excel and Statistical Package for Social Sciences. Senior data at baseline found high rates of polypharmacy and physical imbalance, and no significant depression or gaps in social support. There was not a statistically significant change pre- to post-program in fall frequency "in prior year." Study findings reveal insights about African American senior health and fall risks. Church settings may provide a protective, psychosocial buffer for seniors, while polypharmacy and mobility/balance concerns indicate need for continued attention to fall risks. No increase in pre- to post-program falls was encouraging.

  12. NSTX Protection And Interlock Systems For Coil And Powers Supply Systems

    International Nuclear Information System (INIS)

    Zhao, X.; Ramakrishnan, S.; Lawson, J.; Neumeyer, C.; Marsala, R.; Schneider, H.

    2009-01-01

    NSTX at Princeton Plasma Physics Laboratory (PPPL) requires sophisticated plasma positioning control system for stable plasma operation. TF magnetic coils and PF magnetic coils provide electromagnetic fields to position and shape the plasma vertically and horizontally respectively. NSTX utilizes twenty six coil power supplies to establish and initiate electromagnetic fields through the coil system for plasma control. A power protection and interlock system is utilized to detect power system faults and protect the TF coils and PF coils against excessive electromechanical forces, overheating, and over current. Upon detecting any fault condition the power system is restricted, and it is either prevented from initializing or suppressed to de-energize coil power during pulsing. Power fault status is immediately reported to the computer system. This paper describes the design and operation of NSTX's protection and interlocking system and possible future expansion.

  13. Albeni Falls Wildlife Mitigation Project, 2008 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Soults, Scott [Kootenai Tribe of Idaho

    2009-08-05

    The Albeni Falls Interagency Work Group (AFIWG) was actively involved in implementing wildlife mitigation activities in late 2007, but due to internal conflicts, the AFIWG members has fractionated into a smaller group. Implementation of the monitoring and evaluation program continued across protected lands. As of 2008, The Albeni Falls Interagency Work Group (Work Group) is a coalition comprised of wildlife managers from three tribal entities (Kalispel Tribe, Kootenai Tribe, Coeur d Alene Tribe) and the US Army Corps of Engineers. The Work Group directs where wildlife mitigation implementation occurs in the Kootenai, Pend Oreille and Coeur d Alene subbasins. The Work Group is unique in the Columbia Basin. The Columbia Basin Fish and Wildlife Authority (CBFWA) wildlife managers in 1995, approved what was one of the first two project proposals to implement mitigation on a programmatic basis. The maintenance of this kind of approach through time has allowed the Work Group to implement an effective and responsive habitat protection program by reducing administrative costs associated with site-specific project proposals. The core mitigation entities maintain approximately 9,335 acres of wetland/riparian habitats in 2008.

  14. System and method for quench protection of a superconductor

    Science.gov (United States)

    Huang, Xianrui; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas

    2008-03-11

    A system and method for protecting a superconductor from a quench condition. A quench protection system is provided to protect the superconductor from damage due to a quench condition. The quench protection system comprises a voltage detector operable to detect voltage across the superconductor. The system also comprises a frequency filter coupled to the voltage detector. The frequency filter is operable to couple voltage signals to a control circuit that are representative of a rise in superconductor voltage caused by a quench condition and to block voltage signals that are not. The system is operable to detect whether a quench condition exists in the superconductor based on the voltage signal received via the frequency filter and to initiate a protective action in response.

  15. Falls and fear of falling predict future falls and related injuries in ambulatory individuals with spinal cord injury: a longitudinal observational study.

    Science.gov (United States)

    Jørgensen, Vivien; Butler Forslund, Emelie; Opheim, Arve; Franzén, Erika; Wahman, Kerstin; Hultling, Claes; Seiger, Åke; Ståhle, Agneta; Stanghelle, Johan K; Roaldsen, Kirsti S

    2017-04-01

    What is the 1-year incidence of falls and injurious falls in a representative cohort of community-dwelling ambulatory individuals with chronic spinal cord injury? What are the predictors of recurrent falls (more than two/year) and injurious falls in this population? One-year longitudinal observational multi-centre study. A representative sample of 68 (of 73 included) community-dwelling ambulatory individuals with traumatic SCI attending regular follow-up programs at rehabilitation centres. Primary outcome measures were incidence and predictors of recurrent falls (more than two/year) and injurious falls reported every 2 weeks for 1year. A total of 48% of participants reported recurrent falls. Of the 272 reported falls, 41% were injurious. Serious injuries were experienced by 4% of participants, all of whom were women. Multivariate logistic regression analysis showed that recurrent falls in the previous year (OR=111, 95% CI=8.6 to 1425), fear of falling (OR=6.1, 95% CI=1.43 to 26) and longer time taken to walk 10m (OR=1.3, 95% CI=1.0 to 1.7) were predictors of recurrent falls. Fear of falling (OR=4.3, 95% CI=1.3 to 14) and recurrent falls in the previous year (OR=4.2, 95% CI=1.2 to 14) were predictors of injurious falls. Ambulatory individuals have a high risk of falling and of fall-related injuries. Fall history, fear of falling and walking speed could predict recurrent falls and injurious falls. Further studies with larger samples are needed to validate these findings. [Jørgensen V, Butler Forslund E, Opheim A, Franzén E, Wahman K, Hultling C, Seiger Å, Ståhle A, Stanghelle JK, Roaldsen KS (2017) Falls and fear of falling predict future falls and related injuries in ambulatory individuals with spinal cord injury: a longitudinal observational study. Journal of Physiotherapy 63: 108-113]. Copyright © 2017 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  16. Unexplained Falls Are Frequent in Patients with Fall-Related Injury Admitted to Orthopaedic Wards: The UFO Study (Unexplained Falls in Older Patients

    Directory of Open Access Journals (Sweden)

    Mussi Chiara

    2013-01-01

    Full Text Available To evaluate the incidence of unexplained falls in elderly patients affected by fall-related fractures admitted to orthopaedic wards, we recruited 246 consecutive patients older than 65 (mean age 82±7 years, range 65–101. Falls were defined “accidental” (fall explained by a definite accidental cause, “medical” (fall caused directly by a specific medical disease, “dementia-related” (fall in patients affected by moderate-severe dementia, and “unexplained” (nonaccidental falls, not related to a clear medical or drug-induced cause or with no apparent cause. According to the anamnestic features of the event, older patients had a lower tendency to remember the fall. Patients with accidental fall remember more often the event. Unexplained falls were frequent in both groups of age. Accidental falls were more frequent in younger patients, while dementia-related falls were more common in the older ones. Patients with unexplained falls showed a higher number of depressive symptoms. In a multivariate analysis a higher GDS and syncopal spells were independent predictors of unexplained falls. In conclusion, more than one third of all falls in patients hospitalized in orthopaedic wards were unexplained, particularly in patients with depressive symptoms and syncopal spells. The identification of fall causes must be evaluated in older patients with a fall-related injury.

  17. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  18. A New Physical Protection System Design and Evaluation Process

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Heoksoon; Kim, Myungsu; Bae, Yeongkyoung; Na, Janghwan [KHNP-CRI, Daejeon (Korea, Republic of)

    2014-10-15

    International Atomic Energy Agency(IAEA) had established security-related department and has been strengthening security measures against possible sabotage. IAEA enforces the recommendations for the physical protection of NPPs in the INFCIRC/ 225/Rev.5 to the member states and U.S. NRC also enforces the similar requirements in 10 CFR 73.55. Thus, in order to let Korean NPPs meet the new requirements in INFCIRC/225/Rev.5 or U.S. NRC requirements, Korea nuclear licensee should develop or establish appropriate physical protection system (PPS) design methods for the physical protection of the operating NPPs and new NPPs. KHNP is doing the project of 'Development of APR1400 Physical Protection System Design (2012- 2015, KHNP/KAERI /KEPCO E-C)'. This paper describes overview of a physical protection system (PPS) design and evaluation for an advanced nuclear power plant. It found that a new physical protection system (PPS)design and evaluation. KHNP is doing the project of Physical Protection System design according to U.S. NRC requirements and IAEA requirements in INFCIRC /225 /Rev.5 and will complete by 7.31, 2015 for development of APR1400 Physical Protection System. After completing this project, the results of project are expected to apply new NPPs.

  19. Associated Factors for Falls, Recurrent Falls, and Injurious Falls in Aged Men Living in Taiwan Veterans Homes

    Directory of Open Access Journals (Sweden)

    Yan-Chiou Ku

    2013-06-01

    Conclusion: This study demonstrated that the advanced age, depression status, stroke, gouty arthritis, and cataract are independent variables for predicting falls; depression is the only clinical factor capable of predicting the recurrent falls. These variables were potential targets for effective prevention of falls.

  20. Management information system applied to radiation protection services

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur

    2013-01-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  1. Management information system applied to radiation protection services

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur, E-mail: pabloag@cdtn.br, E-mail: lss@cdtn.br, E-mail: gmf@cdtn.br, E-mail: arthurqof@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  2. Future Interoperability of Camp Protection Systems (FICAPS)

    Science.gov (United States)

    Caron, Sylvie; Gündisch, Rainer; Marchand, Alain; Stahl, Karl-Hermann

    2013-05-01

    The FICAPS Project has been established as a Project of the European Defence Agency based on an initiative of Germany and France. Goal of this Project was to derive Guidelines, which by a proper implementation in future developments improve Camp Protection Systems (CPS) by enabling and improving interoperability between Camp Protection Systems and its Equipments of different Nations involved in multinational missions. These Guidelines shall allow for: • Real-time information exchange between equipments and systems of different suppliers and nations (even via SatCom), • Quick and easy replacement of equipments (even of different Nations) at run-time in the field by means of plug and play capability, thus lowering the operational and logistic costs and making the system highly available, • Enhancement of system capabilities (open and modular systems) by adding new equipment with new capabilities (just plug-in, automatic adjustment of the HMI Human Machine Interface) without costly and time consuming validation and test on system level (validation and test can be done on Equipment level), Four scenarios have been identified to summarize the interoperability requirements from an operational viewpoint. To prove the definitions given in the Guideline Document, a French and a German Demonstration System, based on existing national assets, were realized. Demonstrations, showing the capabilities given by the defined interoperability requirements with respect to the operational scenarios, were performed. Demonstrations included remote control of a CPS by another CPS, remote sensor control (Electro-Optic/InfraRed EO/IR) and remote effector control. This capability can be applied to extend the protection area or to protect distant infrastructural assets Demonstrations have been performed. The required interoperability functionality was shown successfully. Even if the focus of the FICAPS project was on camp protection, the solution found is also appropriate for other

  3. Falls and fear of falling predict future falls and related injuries in ambulatory individuals with spinal cord injury: a longitudinal observational study

    Directory of Open Access Journals (Sweden)

    Vivien Jørgensen

    2017-04-01

    Conclusion: Ambulatory individuals have a high risk of falling and of fall-related injuries. Fall history, fear of falling and walking speed could predict recurrent falls and injurious falls. Further studies with larger samples are needed to validate these findings. [Jørgensen V, Butler Forslund E, Opheim A, Franzén E, Wahman K, Hultling C, Seiger Å, Ståhle A, Stanghelle JK, Roaldsen KS (2017 Falls and fear of falling predict future falls and related injuries in ambulatory individuals with spinal cord injury: a longitudinal observational study. Journal of Physiotherapy 63: 108–113

  4. Implementation of FPGA-Based Diverse Protection System

    International Nuclear Information System (INIS)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min

    2015-01-01

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails

  5. Implementation of FPGA-Based Diverse Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min [KEPCO Engineering and Construction Company Inc., Daejeon (Korea, Republic of)

    2015-10-15

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails.

  6. Power system EMP protection. Final report

    International Nuclear Information System (INIS)

    Marable, J.H.; Barnes, P.R.; Nelson, D.B.

    1975-05-01

    Voltage transients induced in electric power lines and control circuits by the electromagnetic pulse (EMP) from high-altitude nuclear detonations may cause widespread power failure and damage in electric power systems. This report contains a parametric study of EMP power line surges and discusses protective measures to minimize their effects. Since EMP surges have considerably greater rates of rise than lightning surges, recommended standards and test procedures are given to assure that surge arresters protect equipment from damage by EMP. Expected disturbances and damage to power systems are reviewed, and actions are presented which distribution companies can take to counter them. These include backup communications methods, stockpiling of vulnerable parts, repair procedures, and dispatcher actions to prevent blackout from EMP-caused instabilities. A long-range program is presented for improving distributors' protection against EMP. This involves employee training, hardware protection for power and control circuits, and improvement of plans for emergency action. (U.S.)

  7. In-Space Repair of Reinforced Carbon-Carbon Thermal Protection System Structures

    Science.gov (United States)

    Singh, Mrityunjay

    2006-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, integrated system for tile and leading edge repair (InSTALER) have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  8. Effect of a Multidisciplinary Fall Risk Assessment on Falls Among Neurology Inpatients

    Science.gov (United States)

    Hunderfund, Andrea N. Leep; Sweeney, Cynthia M.; Mandrekar, Jayawant N.; Johnson, LeAnn M.; Britton, Jeffrey W.

    2011-01-01

    OBJECTIVE: To evaluate whether the addition of a physician assessment of patient fall risk at admission would reduce inpatient falls on a tertiary hospital neurology inpatient unit. PATIENTS AND METHODS: A physician fall risk assessment was added to the existing risk assessment process (clinical nurse evaluation and Hendrich II Fall Risk Model score with specific fall prevention measures for patients at risk). An order to select either “Patient is” or “Patient is not at high risk of falls by physician assessment” was added to the physician electronic admission order set. Nurses and physicians were instructed to reach consensus when assessments differed. Full implementation occurred in second-quarter 2008. Preimplementation (January 1, 2006, to March 31, 2008) and postimplementation (April 1, 2008, to December 31, 2009) rates of falls were compared on the neurology inpatient unit and on 6 other medical units that did not receive intervention. RESULTS: The rate of falls during the 7 quarters after full implementation was significantly lower than that during the 9 preceding quarters (4.12 vs 5.69 falls per 1000 patient-days; P=.04), whereas the rate of falls on other medical units did not significantly change (2.99 vs 3.33 falls per 1000 patient-days; P=.24, Poisson test). The consensus risk assessment at admission correctly identified patients at risk for falls (14/325 at-risk patients fell vs 0/147 low-risk patients; P=.01, χ2 test), but the Hendrich II Fall Risk Model score, nurse, and physician assessments individually did not. CONCLUSION: A multidisciplinary approach to fall risk assessment is feasible, correctly identifies patients at risk, and was associated with a reduction in inpatient falls. PMID:21193651

  9. Falls and falls efficacy: the role of sustained attention in older adults

    LENUS (Irish Health Repository)

    O'Halloran, Aisling M

    2011-12-19

    Abstract Background Previous evidence indicates that older people allocate more of their attentional resources toward their gait and that the attention-related changes that occur during aging increase the risk of falls. The aim of this study was to investigate whether performance and variability in sustained attention is associated with falls and falls efficacy in older adults. Methods 458 community-dwelling adults aged ≥ 60 years underwent a comprehensive geriatric assessment. Mean and variability of reaction time (RT), commission errors and omission errors were recorded during a fixed version of the Sustained Attention to Response Task (SART). RT variability was decomposed using the Fast Fourier Transform (FFT) procedure, to help characterise variability associated with the arousal and vigilance aspects of sustained attention. The number of self-reported falls in the previous twelve months, and falls efficacy (Modified Falls Efficacy Scale) were also recorded. Results Significant increases in the mean and variability of reaction time on the SART were significantly associated with both falls (p < 0.01) and reduced falls efficacy (p < 0.05) in older adults. An increase in omission errors was also associated with falls (p < 0.01) and reduced falls efficacy (p < 0.05). Upon controlling for age and gender affects, logistic regression modelling revealed that increasing variability associated with the vigilance (top-down) aspect of sustained attention was a retrospective predictor of falling (p < 0.01, OR = 1.14, 95% CI: 1.03 - 1.26) in the previous year and was weakly correlated with reduced falls efficacy in non-fallers (p = 0.07). Conclusions Greater variability in sustained attention is strongly correlated with retrospective falls and to a lesser degree with reduced falls efficacy. This cognitive measure may provide a novel and valuable biomarker for falls in older adults, potentially allowing for early detection and the implementation of preventative intervention

  10. A Cause-Consequence Chart of a Redundant Protection System

    DEFF Research Database (Denmark)

    Nielsen, Dan Sandvik; Platz, O.; Runge, B.

    1975-01-01

    A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy of compone...... of components is taken into account. The possibility of using parameter variation as a basis for the choice of test policy is indicated.......A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy...

  11. Using Akka Platform in Unidentified Falling Object Detection on the LHC.

    CERN Document Server

    Motesnitsalis, Evangelos

    2013-01-01

    During my participation in the CERN Summer Student Program 2013, I worked under the Technology Department of CERN and, more specifically, in the Machine Protection and Electrical Integrity (MPE) Group. The MPE Group supports LHC operation and maintains state‐of‐the art technology for magnet circuit protection and interlock systems for the present and future accelerators, magnet test facilities and CERN hosted experiments. Within this context, we developed an application that parallelizes the Unidentified Falling Object Detection Algorithm on the LHC Operational Data Analysis Software. For this reason, we used a JVM-based toolkit, named Akka, which parallelizes the execution by creating a number of actors that run simultaneously. The results of the new approach are presented on the last part of this report. They tend to be quite interesting and promising as we managed to reduce the execution time of the analysis by a factor of 10 on a local machine and the first attempts to execute the program on a cluster...

  12. Angle Control-Based Multi-Terminal Out-of-Step Protection System

    Directory of Open Access Journals (Sweden)

    Antans Sauhats

    2017-03-01

    Full Text Available From time to time a sequence of unexpected and overlapping contingencies may lead to power system angular instability and even blackouts if not addressed adequately by means of an out-of-step (OOS protection system. The motivation of the paper is an attempt to develop a workable prototype of the OOS protection system. The deficiencies of the protection currently used in the Latvian Power System network are highlighted and a new protection structure is proposed. The protection system comprises of several strategically located terminals, exchanging information in real time by means of a communication network. The OOS condition detection method is based on system-wide generation sources, electromotive forces, vectors, and angle control. The network splitting decision is based on generator coherence evaluation. Protection terminals determine online the groups of coherent generators and choose the splitting boundary from a predefined transmission lines (TLs cut sets list. The protection system structure, algorithm of operation, and possible IEC 61850 communication standard-based implementation are described.

  13. The consumption of two or more fall risk-increasing drugs rather than polypharmacy is associated with falls.

    Science.gov (United States)

    Zia, Anam; Kamaruzzaman, Shahrul B; Tan, Maw P

    2017-03-01

    The presemt study aimed to determine the association between the risk of recurrent and injurious falls with polypharmacy, fall risk-increasing drugs (FRID) and FRID count among community-dwelling older adults. Participants (n = 202) were aged ≥65 years with two or more falls or one injurious fall in the past year, whereas controls (n = 156) included volunteers aged ≥65 years with no falls in the past year. A detailed medication history was obtained alongside demographic data. Polypharmacy was defined as "regular use of five or more prescription drugs." FRID were identified as cardiovascular agents, central nervous system drugs, analgesics and endocrine drugs; multiple FRID were defined as two or more FRID. Multiple logistic regression analyses were used to adjust for confounders. The use of non-steroidal anti-inflammatory drugs was independently associated with an increased risk of falls. Univariate analyses showed both polypharmacy (OR 2.23, 95% CI 1.39-3.56; P = 0.001) and the use of two or more FRID (OR 2.9, 95% CI 1.9-4.5; P = 0.0001) were significantly more likely amongst fallers. After adjustment for age, sex and comorbidities, blood pressure, and physical performance scores, polypharmacy was no longer associated with falls (OR 1.6, 95% CI 0.9-2.9; P = 0.102), whereas the consumption of two or more FRID remained a significant predictor for falls (OR 2.8, 95% CI 1.4-5.3; P = 0.001). Among high risk fallers, the use of two or more FRID was an independent risk factor for falls instead of polypharmacy. Our findings will inform clinical practice in terms of medication reviews among older adults at higher risk of falls. Future intervention studies will seek to confirm whether avoidance or withdrawal of multiple FRID reduces the risk of future falls. Geriatr Gerontol Int 2017; 17: 463-470. © 2016 Japan Geriatrics Society.

  14. Integrated crop protection as a system approach

    OpenAIRE

    Haan, de, J.J.; Wijnands, F.G.; Sukkel, W.

    2005-01-01

    New farming systems in vegetable production are required as demands for high quality products that do not pollute the environment are rising, and production risks are large and incomes low. The methodology of prototyping new systems is described, especially the themes, parameters and target values connected to integrated crop protection. The role of integrated crop protection in prototyping new systems is discussed. The results of twenty years working with this prototyping methodology are pre...

  15. MGR COMPLIANCE PROGRAM GUIDANCE PACKAGE FOR RADIATION PROTECTION EQUIPMENT, INSTRUMENTATION, AND FACILITIES

    International Nuclear Information System (INIS)

    2000-01-01

    This Compliance Program Guidance Package identifies the regulatory guidance and industry codes and standards addressing radiation protection equipment, instrumentation, and support facilities considered to be appropriate for radiation protection at the Monitored Geologic Repository (MGR). Included are considerations relevant to radiation monitoring instruments, calibration, contamination control and decontamination, respiratory protection equipment, and general radiation protection facilities. The scope of this Guidance Package does not include design guidance relevant to criticality monitoring, area radiation monitoring, effluent monitoring, and airborne radioactivity monitoring systems since they are considered to be the topics of specific design and construction requirements (i.e., ''fixed'' or ''built-in'' systems). This Guidance Package does not address radiation protection design issues; it addresses the selection and calibration of radiation monitoring instrumentation to the extent that the guidance is relevant to the operational radiation protection program. Radon and radon progeny monitoring instrumentation is not included in the Guidance Package since such naturally occurring radioactive materials do not fall within the NRC's jurisdiction at the MGR

  16. The Protective Arm of the Renin Angiotensin System (RAS)

    DEFF Research Database (Denmark)

    understanding of the protective side of the Renin Angiotensin System (RAS) involving angiotensin AT2 receptor, ACE2, and Ang(1-7)/Mas receptor Combines the knowledge of editors who pioneered research on the protective renin angiotensin system including; Dr. Thomas Unger, one of the founders of AT2 receptor......The Protective Arm of the Renin Angiotensin System: Functional Aspects and Therapeutic Implications is the first comprehensive publication to signal the protective role of a distinct part of the renin-angiotensin system (RAS), providing readers with early insight into a complex system which...... will become of major medical importance in the near future. Focusing on recent research, The Protective Arm of the Renin Angiotensin System presents a host of new experimental studies on specific components of the RAS, namely angiotensin AT2 receptors (AT2R), the angiotensin (1-7) peptide with its receptor...

  17. 75 FR 972 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2010-01-07

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department of... Federal, State and territorial marine protected area programs to join the National System of Marine Protected Areas. SUMMARY: NOAA and the Department of the Interior (DOI) invited Federal, State, commonwealth...

  18. Fall Risk, Supports and Services, and Falls Following a Nursing Home Discharge.

    Science.gov (United States)

    Noureldin, Marwa; Hass, Zachary; Abrahamson, Kathleen; Arling, Greg

    2017-09-04

    Falls are a major source of morbidity and mortality among older adults; however, little is known regarding fall occurrence during a nursing home (NH) to community transition. This study sought to examine whether the presence of supports and services impacts the relationship between fall-related risk factors and fall occurrence post NH discharge. Participants in the Minnesota Return to Community Initiative who were assisted in achieving a community discharge (N = 1459) comprised the study sample. The main outcome was fall occurrence within 30 days of discharge. Factor analyses were used to estimate latent models from variables of interest. A structural equation model (SEM) was estimated to determine the relationship between the emerging latent variables and falls. Fifteen percent of participants fell within 30 days of NH discharge. Factor analysis of fall-related risk factors produced three latent variables: fall concerns/history; activities of daily living impairments; and use of high-risk medications. A supports/services latent variable also emerged that included caregiver support frequency, medication management assistance, durable medical equipment use, discharge location, and receipt of home health or skilled nursing services. In the SEM model, high-risk medications use and fall concerns/history had direct positive effects on falling. Receiving supports/services did not affect falling directly; however, it reduced the effect of high-risk medication use on falling (p risk of falling post NH discharge. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Dynamic loading of the structural wall in a lithium fall fusion reactor

    International Nuclear Information System (INIS)

    Glenn, L.A.

    1979-01-01

    In one version of an inertial confinement fusion (ICF) power reactor, the laser-imploded pellet is surrounded by a thick, annular 'waterfall' of liquid lithium. The fall has three functions: to breed tritium for pellet resupply, to act as an energy sink and heat exchange mdeium with an external power loop, and to protect the first wall of the reactor from excessive neutronic and hydrodynamic loading. Our primary concern here is with this last function. We formulated a simple model of a lithium-fall ICF reactor and calculated the fall disassembly and the subsequent fluid-wall interaction resulting from the energy deposition by the imploded pellet. Two potential mechanisms for wall damage were identified: surface erosion and hoop failure. For single fall designs, the erosion problem appears to be serious. Concentric annuli (multiple fall) or packed jet configurations may be feasible but experiments are needed to clarify the physical model, especially with reg (orig.)ard to /orig.the characteristics of the cavitated liquid lithium and of the two-phase liquid-vapor region.

  20. Where attention falls: Increased risk of falls from the converging impact of cortical cholinergic and midbrain dopamine loss on striatal function.

    Science.gov (United States)

    Sarter, Martin; Albin, Roger L; Kucinski, Aaron; Lustig, Cindy

    2014-07-01

    Falls are a major source of hospitalization, long-term institutionalization, and death in older adults and patients with Parkinson's disease (PD). Limited attentional resources are a major risk factor for falls. In this review, we specify cognitive-behavioral mechanisms that produce falls and map these mechanisms onto a model of multi-system degeneration. Results from PET studies in PD fallers and findings from a recently developed animal model support the hypothesis that falls result from interactions between loss of basal forebrain cholinergic projections to the cortex and striatal dopamine loss. Striatal dopamine loss produces inefficient, low-vigor gait, posture control, and movement. Cortical cholinergic deafferentation impairs a wide range of attentional processes, including monitoring of gait, posture and complex movements. Cholinergic cell loss reveals the full impact of striatal dopamine loss on motor performance, reflecting loss of compensatory attentional supervision of movement. Dysregulation of dorsomedial striatal circuitry is an essential, albeit not exclusive, mediator of falls in this dual-system model. Because cholinergic neuromodulatory activity influences cortical circuitry primarily via stimulation of α4β2* nicotinic acetylcholine receptors, and because agonists at these receptors are known to benefit attentional processes in animals and humans, treating PD fallers with such agonists, as an adjunct to dopaminergic treatment, is predicted to reduce falls. Falls are an informative behavioral endpoint to study attentional-motor integration by striatal circuitry. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Discussion on radiation protection system from ethical issues

    International Nuclear Information System (INIS)

    Li, Xutong; Guo, Qiuju

    2002-01-01

    This paper discussed the relationship between radiation protection system and ethical principle, viz. equity and efficiency. According to the authors' opinions, the main problem that the system of radiation protection facing now is the dose-limitation principle cannot incarnate the equity principle completely. Even though the distinguishing between practice and intervention is no other than solving the problem, but the scheme is not perfect still. Ethical issues should be given more attention and be more researched when we try to modify the radiation protection system today

  2. Review of fall risk assessment in geriatric populations using inertial sensors

    OpenAIRE

    Howcroft, Jennifer; Kofman, Jonathan; Lemaire, Edward D

    2013-01-01

    Background Falls are a prevalent issue in the geriatric population and can result in damaging physical and psychological consequences. Fall risk assessment can provide information to enable appropriate interventions for those at risk of falling. Wearable inertial-sensor-based systems can provide quantitative measures indicative of fall risk in the geriatric population. Methods Forty studies that used inertial sensors to evaluate geriatric fall risk were reviewed and pertinent methodological f...

  3. Novel Directional Protection Scheme for the FREEDM Smart Grid System

    Science.gov (United States)

    Sharma, Nitish

    This research primarily deals with the design and validation of the protection system for a large scale meshed distribution system. The large scale system simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms, to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. The addition of distributed generation and power electronic based solid state transformer adds to the complexity of the protection. The FREEDM loop system has a fault current limiter and in addition, the Solid State Transformer (SST) limits the fault current at 2.0 per unit. Former students at ASU have developed the protection scheme using fiber-optic cable. However, during the NSF-FREEDM site visit, the National Science Foundation (NSF) team regarded the system incompatible for the long distances. Hence, a new protection scheme with a wireless scheme is presented in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The trip signal generated by the pilot protection system is used to trigger the FID (fault isolation device) which is an electronic circuit breaker operation (switched off/opening the FIDs). The trip signal must be received and accepted by the SST, and it must block the SST operation immediately. A comprehensive protection system for the large scale meshed distribution system has been developed in PSCAD with the ability to quickly detect the faults. The validation of the protection system is performed by building a hardware model using commercial relays at the ASU power laboratory.

  4. Do Canes or Walkers Make Any Difference? NonUse and Fall Injuries.

    Science.gov (United States)

    Luz, Clare; Bush, Tamara; Shen, Xiaoxi

    2017-04-01

    Examine patterns of cane and walker use as related to falls and fall injuries. Among people who fall at home, most do not have an assistive device with them when they fall. Nonusers who fall sustain more severe injuries. This was a cross-sectional study using a self-administered written survey completed by 262 people aged 60 and older who were community dwelling, cognitively intact, and current cane/walker users with a history of falls. They were recruited through clinical practice sites, churches, and senior housing in central Michigan. Outcomes of interest included patterns of device use, reasons for nonuse, device use at time of fall, and fall-related injuries. Seventy-five percent of respondents who fell were not using their device at the time of fall despite stating that canes help prevent falls. Reasons for nonuse included believing it was not needed, forgetfulness, the device made them feel old, and inaccessibility. Perceived risk was not high enough to engage in self-protective behavior. However, nonuse led to a significantly higher proportion of falls resulting in surgery than among device users. Among respondents requiring surgery, 100% were nonusers. Most respondents never received a home safety evaluation (68%) and only 50% received training on proper device use. Providers must place increased emphasis on the importance of cane/walker use for injury prevention through patient education to promote personal relevance, proper fitting, and training. New strategies are needed to improve device acceptability and accessibility. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Power system protection 1 principles and components

    CERN Document Server

    Association, Electricity Training

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  6. Falls in multiple sclerosis.

    Science.gov (United States)

    Matsuda, Patricia N; Shumway-Cook, Anne; Bamer, Alyssa M; Johnson, Shana L; Amtmann, Dagmar; Kraft, George H

    2011-07-01

    To examine incidence, associated factors, and health care provider (HCP) response to falls in persons with multiple sclerosis (MS). Cross-sectional retrospective design. Community setting. Four hundred seventy-four persons with MS. Mailed survey questionnaire examined incidence, risk factors, and HCP response to falls in persons with MS who were dwelling in the community. Univariate and multiple ordinal regression analysis identified variables associated with single and multiple falls. Falls, causes and perceived reasons for falls, and HCP response. A total of 265 participants (58.2%) reported one or more falls in the previous 6 months, and 58.5% of falls were medically injurious. Trips/slips while walking accounted for 48% of falls. Factors associated with falls included use of a cane or walker (odds ratio [OR] 2.62; 95% confidence interval [CI] 1.66-4.14), income falls; recommended strategies included safety strategies (53.2%), use of gait assistive devices (42.1%), exercise/balance training (22.2%), and home modifications (16.6%). Factors associated with falls in persons with MS are similar to those in other populations with neurologic diseases. Despite the high incidence of falls, fewer than 50% of people with MS receive information about prevention of falls from an HCP. Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Nuclear fall-out shelter

    International Nuclear Information System (INIS)

    Lowery, R.J.

    1981-01-01

    An underground nuclear fall-out shelter has a plastics shell which, apart from service and access openings, is waterproof and provided, if desired, with a concrete roof. The shelter has an access opening, an air system, lighting, water storage, sanitation and sewage facilities. (author)

  8. Exploring Older Adult ED Fall Patients' Understanding of Their Fall: A Qualitative Study.

    Science.gov (United States)

    Shankar, Kalpana N; Taylor, Devon; Rizzo, Caroline T; Liu, Shan W

    2017-12-01

    We sought to understand older patients' perspectives about their fall, fall risk factors, and attitude toward emergency department (ED) fall-prevention interventions. We conducted semistructured interviews between July 2015 and January 2016 of community-dwelling, nondemented patients in the ED, who presented with a fall to an urban, teaching hospital. Interviews were halted once we achieve thematic saturation with the data coded and categorized into themes. Of the 63 patients interviewed, patients blamed falls on the environment, accidents, a medical condition, or themselves. Three major themes were generated: (1) patients blamed falls on a multitude of things but never acknowledged a possible multifactorial rationale, (2) patients have variable level of concerns regarding their current fall and future fall risk, and (3) patients demonstrated a range of receptiveness to ED interventions aimed at preventing falls but provided little input as to what those interventions should be. Many older patients who fall do not understand their fall risk. However, based on the responses provided, older adults tend to be more receptive to intervention and more concerned about their future fall risk, making the ED an appropriate setting for intervention.

  9. 78 FR 44475 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-07-24

    ... that the performance or product has some reliability-related value, then the requirement will have...] Protection System Maintenance Reliability Standard AGENCY: Federal Energy Regulatory Commission, Energy... Commission proposes to approve a revised Reliability Standard, PRC-005- 2--Protection System Maintenance, to...

  10. Medication use and fall-risk assessment for falls in an acute care hospital.

    Science.gov (United States)

    Chiu, Ming-Huang; Lee, Hsin-Dai; Hwang, Hei-Fen; Wang, Shih-Chieh; Lin, Mau-Roung

    2015-07-01

    A nested case-control study was carried out to examine relationships of a fall-risk score and the use of single medications and polypharmacy with falls among hospitalized patients aged 50 years and older in Taiwan. There were 83 patients who experienced a fall during hospitalization in an acute-care hospital. Matched by age and sex, five control patients for each case were randomly selected from all other inpatients who had not experienced any fall at the time of the index fall. Patients who took tricyclic antidepressants, diuretics, and narcotics were 3.36-, 1.83- and 2.09-fold, respectively, more likely to experience a fall than their counterparts. Conversely, patients who took beta-blockers were 0.34-fold more likely than those who did not take them to experience a fall. Patients taking ≥6 medications were 3.08-fold more likely than those taking fewer medications to experience a fall, whereas those with anxiety were 4.72-fold more likely to experience a fall than those without. A high fall-risk score was not significantly associated with the occurrence of falls. Among older hospitalized patients, tricyclic antidepressants, diuretics, narcotics, and polypharmacy should be mindfully prescribed and reviewed on a regular basis. A fall-risk scale developed from community-dwelling older people might not accurately predict falls in hospitalized patients. Further research to validate the negative effect of beta-blocker use on falls is required. © 2014 Japan Geriatrics Society.

  11. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  12. 33 CFR 142.30 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Head protection. 142.30 Section 142.30 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER... protection. (a) Personnel in areas where there is a hazard of falling objects or of contact with electrical...

  13. Regulatory System of Radiation Protection in Taiwan

    International Nuclear Information System (INIS)

    Tang, F. T.; Huang, C. C.

    2004-01-01

    After the radioactive contaminated buildings incident occurred in Taiwan in 1993, the competent authority for radiation protection the Atomic Energy Council (AEC) started to review the structured problem of radiation protection regulatory system. Through several years' investigation and study, the AEC has improved two important tools in radiation protection regulatory system, i.e., control regulations and actual practice, and made them more rigorous and efficient. This paper will make a brief introduction of the efforts that Taiwan has made in this respect. Taiwan's radiation protection control was based on the Atomic Energy Law promulgated in 1968, but the control idea and authorization scope were not sufficient to appropriately respond to the highly developed economy and democracy in Taiwan. After several years' legislative process, the Ionizing Radiation Protection Law (IRP Law) was promulgated and entered into force on February 1, 2003. This IRP Law specifically emphasizes categorized risk management of radiation sources, establishment of personnel licenses and training system, enhancement of public safety control, and implementation of quality assurance program for medical exposure. The Legislative Yuan (Congress) fully authorized the competent authority to establish various technological control regulations according to control necessity without prior review by the Legislative Yuan in advance. As to the penalties of the violations of the IRP Law, the AEC adopts high-rated administrative fines and applies the Criminal Law to those who seriously contaminate the environment. In actual practice, the AEC has constructed a Radiation Protection Control Information System compatible with the IRP Law that fully combines the functions of computers and Internet. The information of facility operators who own radiation sources, radiation protection specialists, and operating personnel are entered into this system, starting from the submission of application of the

  14. Which Fall Ascertainment Method Captures Most Falls in Pre-Frail and Frail Seniors?

    Science.gov (United States)

    Teister, Corina J; Chocano-Bedoya, Patricia O; Orav, Endel J; Dawson-Hughes, Bess; Meyer, Ursina; Meyer, Otto W; Freystaetter, Gregor; Gagesch, Michael; Rizzoli, Rene; Egli, Andreas; Theiler, Robert; Kanis, John A; Bischoff-Ferrari, Heike A

    2018-06-15

    There is no consensus on most reliable falls ascertainment method. Therefore, we investigated which method captures most falls among pre-frail and frail seniors from two randomized controlled trials conducted in Zurich, Switzerland, a 18-month trial (2009-2010) including 200 community-dwelling pre-frail seniors with a prior fall and a 12-month trial (2005-2008) including 173 frail seniors with acute hip fracture. Both included the same fall ascertainment methods: monthly active-asking, daily self-report diary, and a call-in hotline. We compared number of falls reported and estimated overall and positive percent agreement between methods. Pre-frail seniors reported 499 falls (rate = 2.5/year) and frail seniors reported 205 falls (rate = 1.4/year). Most falls were reported by active-asking: 81% of falls in pre-frail, and 78% in frail seniors. Among pre-frail seniors, diaries captured additional 19% falls, while hotline added none. Among frail seniors, hotline added 16% falls, while diaries added 6%. The positive percent agreement between active-asking and diary was 100% among pre-frail and 88% among frail seniors. While monthly active-asking captures most falls in both groups, this method alone missed 19% of falls in pre-frail and 22% in frail seniors. Thus, a combination of active-asking and diaries for pre-frail, and active-asking and the hotline for frail seniors is warranted.

  15. Near-falls in people with Parkinson's disease: Circumstances, contributing factors and association with falling.

    Science.gov (United States)

    Gazibara, Tatjana; Kisic Tepavcevic, Darija; Svetel, Marina; Tomic, Aleksandra; Stankovic, Iva; Kostic, Vladimir S; Pekmezovic, Tatjana

    2017-10-01

    To describe circumstances of near-falls among persons with Parkinson's disease (PD), assess factors associated with near-falling and assess whether near-falls in the first 6 months are associated with falling in the latter 6 months over one year of follow-up. In the period August 2011-December 2012, 120 consecutive persons with PD, who denied having fallen in the past 6 months, were recruited at Clinical center of Serbia in Belgrade. Occurrence of falling and near-falls was followed for one year. A total of 31 persons with PD (25.8%) experienced near-falls, but did not fall. Of 42 fallers, 32 (76.2%) experienced near-falls. Tripping was the most common cause of near-falls among fallers, whereas postural instability was the most common in non-fallers. Regardless of falling experience, the most common manner to avoid fall was holding onto furniture or wall. After adjustment for multiple motor and non-motor PD features, more severe freezing of gait was associated with occurrence of near-falls over one year of follow-up (odds ratio [OR]=1.08, 95% confidence interval [CI] 1.01-1.16; p=0.043). Adjusted regression analysis did not show associations between near-falling in the first 6 months and falling in the latter 6 months of follow-up. Near-falls commonly occur in persons with PD. More severe freezing of gait appears to predispose near-falling. Fall prevention programs focusing on balance maintenance when experiencing freezing of gait could potentially be useful in reduction of near-falls. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  17. Geriatric fall-related injuries.

    African Journals Online (AJOL)

    Conclusion: The majority of geriatric fall-related injuries were due to fall from the same level at home. Assessment of risk fac- tors for falls including home hazards is essential for prevention of geriatric fall-related injuries. Keywords: Accidental fall, geriatrics, injury, trauma registry. DOI: http://dx.doi.org/10.4314/ahs.v16i2.24.

  18. Modeling Parkinson’s Disease Falls Associated With Brainstem Cholinergic Systems Decline

    OpenAIRE

    Kucinski, Aaron; Sarter, Martin

    2015-01-01

    In addition to the primary disease-defining symptoms, approximately half of patients with Parkinson’s disease (PD) suffer from postural instability, impairments in gait control and a propensity for falls. Consistent with evidence from patients, we previously demonstrated that combined striatal dopamine (DA) and basal forebrain (BF) cholinergic cell loss causes falls in rats traversing dynamic surfaces. Because evidence suggests that degeneration of brainstem cholinergic neurons arising from t...

  19. Design and evaluation of physical protection systems of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model.

  20. Criminal law repercussions on the Civil Protection System

    Science.gov (United States)

    Altamura, M.; Musso, L.

    2009-09-01

    The legal systems of our Countries provide the citizenship with a high level of protection. Personal safety and the protection of property are guaranteed by the State through organized structures among which we can include the Civil Protection. The progress of science and technology has greatly improved monitoring tools, currently used by the Civil Protection, which allow, to a certain extent, to predict and prevent risk and natural hazards. The assertion of an individual right, which in some cases has reached a constitutional rank, to benefit from Civil Protection services and the widespread perception throughout the citizenship of the competence of the system to prevent disasters, often causes people to take legal action against Civil Protection authorities should they fail in their duties to protect. However, the attempt of having both recognized an economic compensation for the suffered loss and the punishment of those whom misled, frequently undergoes criminal law. This process could have results that may jeopardize the effectiveness of Civil Protection service without meeting citizens’ demands. A dual effort is thus necessary in order to solve such a problem. On the one hand, an interdisciplinary knowledge needs to pervade criminal law in an attempt to relieve its self-referentiality and pretended supremacy. On the other hand an alternative, and more agile, system -such as civil or administrative law- has to be identified in order to respond to the legitimate requests for protection in the case of a faulty behaviour of the authorities.

  1. Distributed systems for protecting nuclear power stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-05-01

    The advantages of distributed control systems for the control of nuclear power stations are obviously of great interest. Some years ago, EPRI, (Electric Power Research Institute) showed that multiplexing the signals is technically feasible, that it enables the availability specifications to be met and costs to be reduced. Since then, many distributed control systems have been proposed by the manufacturers. This note offers some comments on the application of the distribution concept to protection systems -what should be distributed- and ends with a brief description of a protection system based on microprocessors for the pressurized power stations now being built in France [fr

  2. Distributed systems for the protection of nuclear stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-01-01

    The advantages of distributed control systems usually mentioned are improved exploitation, cost reduction, and adaptation to changes in technology. These advantages are obviously very interesting for nuclear power plant applications, and many such systems have been proposed. This note comments on the application of the distributed system concept to protection systems - what should be distributed - and closes with a brief description of a protection system based on microprocessors for pressurized water stations being built in France. (auth) [fr

  3. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2005-11-01

    One of the main challenges facing radiological protection experts is how to integrate radiological protection within modern concepts of and approaches to risk governance. It is within this context that the International Commission on Radiological Protection (ICRP) decided to develop new general recommendations to replace its Publication 60 recommendations of 1990. In the process of developing these new recommendations, the views of the ICRP have evolved significantly, largely due to stakeholder involvement that has been actively solicited by the ICRP. In this regard, it was upheld during the First Asian Regional Conference organised by the NEA in October 2002 that the implementation of the new system must allow for regional, societal and cultural differences. In order to ensure appropriate consideration of these differences, the NEA organised the Second Asian Regional Conference on the Evolution of the System of Radiological Protection. Held in Tokyo on 28-29 July 2004, the conference included presentations by the ICRP Chair as well as by radiological experts from Australia, China, Japan and Korea. Within their specific cultural and socio-political milieu, Asia-Pacific and western ways of thought on how to improve the current system of radiological protection were presented and discussed. These ways of thinking, along with a summary of the conference results, are described in these proceedings. (author)

  4. Determinants of disparities between perceived and physiological risk of falling among elderly people: cohort study.

    Science.gov (United States)

    Delbaere, Kim; Close, Jacqueline C T; Brodaty, Henry; Sachdev, Perminder; Lord, Stephen R

    2010-08-18

    To gain an understanding of elderly people's fear of falling by exploring the prevalence and determinants of perceived and physiological fall risk and to understand the role of disparities in perceived and physiological risk in the cause of falls. Prospective cohort study. Community sample drawn from eastern Sydney, Australia. 500 men and women aged 70-90 years. Baseline assessment of medical, physiological, and neuropsychological measures, with physiological fall risk estimated with the physiological profile assessment, and perceived fall risk estimated with the falls efficacy scale international. Participants were followed up monthly for falls over one year. Multivariate logistic regression analyses showed that perceived and physiological fall risk were both independent predictors of future falls. Classification tree analysis was used to split the sample into four groups (vigorous, anxious, stoic, and aware) based on the disparity between physiological and perceived risk of falling. Perceived fall risk was congruent with physiological fall risk in the vigorous (144 (29%)) and aware (202 (40%)) groups. The anxious group (54 (11%)) had a low physiological risk but high perceived fall risk, which was related to depressive symptoms (P=0.029), neurotic personality traits (P=0.026), and decreased executive functioning (P=0.010). The stoic group (100 (20%)) had a high physiological risk but low perceived fall risk, which was protective for falling and mediated through a positive outlook on life (P=0.001) and maintained physical activity and community participation (P=0.048). Many elderly people underestimated or overestimated their risk of falling. Such disparities between perceived and physiological fall risk were primarily associated with psychological measures and strongly influenced the probability of falling. Measures of both physiological and perceived fall risk should be included in fall risk assessments to allow tailoring of interventions for preventing falls in

  5. Validation of the Saskatoon Falls Prevention Consortium's Falls Screening and Referral Algorithm

    Science.gov (United States)

    Lawson, Sara Nicole; Zaluski, Neal; Petrie, Amanda; Arnold, Cathy; Basran, Jenny

    2013-01-01

    ABSTRACT Purpose: To investigate the concurrent validity of the Saskatoon Falls Prevention Consortium's Falls Screening and Referral Algorithm (FSRA). Method: A total of 29 older adults (mean age 77.7 [SD 4.0] y) residing in an independent-living senior's complex who met inclusion criteria completed a demographic questionnaire and the components of the FSRA and Berg Balance Scale (BBS). The FSRA consists of the Elderly Fall Screening Test (EFST) and the Multi-factor Falls Questionnaire (MFQ); it is designed to categorize individuals into low, moderate, or high fall-risk categories to determine appropriate management pathways. A predictive model for probability of fall risk, based on previous research, was used to determine concurrent validity of the FSRI. Results: The FSRA placed 79% of participants into the low-risk category, whereas the predictive model found the probability of fall risk to range from 0.04 to 0.74, with a mean of 0.35 (SD 0.25). No statistically significant correlation was found between the FSRA and the predictive model for probability of fall risk (Spearman's ρ=0.35, p=0.06). Conclusion: The FSRA lacks concurrent validity relative to to a previously established model of fall risk and appears to over-categorize individuals into the low-risk group. Further research on the FSRA as an adequate tool to screen community-dwelling older adults for fall risk is recommended. PMID:24381379

  6. The functional assessment Berg Balance Scale is better capable of estimating fall risk in the elderly than the posturographic Balance Stability System

    Directory of Open Access Journals (Sweden)

    Vanessa Vieira Pereira

    2013-01-01

    Full Text Available The purpose of this study was to verify which instrument better identifies recurrent falls in the elderly. Ninety-eight old people, with an average age of 80±4 years, were submitted to an assessment of balance and fall risk by means of the Berg Balance Scale (BBS and the posturographic Balance Stability System (BSS. The BBS was correlated with the BSS (r=-0.27; p=0.008, age (r=-0.38; p<0.001 and number of falls (r=-0.25; p=0.013 and the analysis of logistical regression showed that the elderly classified with fall risk on the BBS presented 2.5 (95%CI 1.08-5.78 more chance of identifying who had two falls or more over the last year. The BBS identified that the greater the age the worse the functional balance and demonstrated a greater capacity to identify falls risk suffered over the last year when compared with the BSS.

  7. Decentralized Adaptive Overcurrent Protection for Medium Voltage Maritime Power Systems

    DEFF Research Database (Denmark)

    Ciontea, Catalin-Iosif; Bak, Claus Leth; Blaabjerg, Frede

    2016-01-01

    the entire electrical network and changes the relay settings accordingly, but this approach is not adequate for the maritime power systems. This paper propose a decentralized adaptive protection method, where each protection relay is able to identify by itself the network status without the need of a central...... control unit. The new adaptive protection method is based on communication between the overcurrent relays and the equipment that could affect the protection system, such as circuit breakers and generators. Using PSCAD, the proposed method is implemented in a test medium voltage maritime power system......More and more maritime applications as marine vessels and offshore platforms need an adaptive protection power system. However, the adaptive protection is yet to be implemented in the maritime sector. Usually, the adaptive protection implies the existence of a central control unit that monitors...

  8. Epidemiology of falls in older adults in Texas.

    Science.gov (United States)

    Alamgir, Hasanat; Wong, Nicole J; Hu, Yueha; Yu, Mo; Marshall, Amanda; Yu, Shicheng

    2015-02-01

    The expected increase in the US older adult population implies an increased risk of fall-related injury among these individuals. We describe the epidemiology of fall morbidity among older adults in Texas, a large US state with a diverse population base. Texas Behavioral Risk Factor Surveillance System 2010 data were analyzed. The falls outcome was defined as falling: any fall in the past 3 months and a serious fall: a fall resulting in limited activities for at least 1 day or requiring medical attention. A total of 5996 subjects were included in this analysis; 17.6% (n = 1055) reported falling 1 to 5 times in the previous 3 months, and 361 (6%) experienced serious falls. Risk of falling had a significant positive association among respondents who rated their general health as fair to poor (relative risk [RR] 2.39, 95% confidence interval [CI] 1.55-3.68) and a negative association for those who reported regular physical activity (RR 0.59, 95% CI 0.42-0.82). A similar model examined the risk of serious falls and found statistically positive associations in respondents who reported fair or poor general health (RR 3.29, 95% CI 2.00-5.43). Negative associations were found for those who reported regular physical activity (RR 0.56, 95% CI 0.38-0.83) and for men (RR 0.62, 95% CI 0.39-0.98). No statistically significant correlations for either of the fall outcomes were found with residence, obesity, education, income, age, ethnicity, employment, marital status, diabetes mellitus, or cardiovascular disease. Interventions aimed at the prevention of falls should focus on maintaining and improving general health and promoting physical activity among older adults.

  9. Displacements of Metallic Thermal Protection System Panels During Reentry

    Science.gov (United States)

    Daryabeigi, Kamran; Blosser, Max L.; Wurster, Kathryn E.

    2006-01-01

    Bowing of metallic thermal protection systems for reentry of a previously proposed single-stage-to-orbit reusable launch vehicle was studied. The outer layer of current metallic thermal protection system concepts typically consists of a honeycomb panel made of a high temperature nickel alloy. During portions of reentry when the thermal protection system is exposed to rapidly varying heating rates, a significant temperature gradient develops across the honeycomb panel thickness, resulting in bowing of the honeycomb panel. The deformations of the honeycomb panel increase the roughness of the outer mold line of the vehicle, which could possibly result in premature boundary layer transition, resulting in significantly higher downstream heating rates. The aerothermal loads and parameters for three locations on the centerline of the windward side of this vehicle were calculated using an engineering code. The transient temperature distributions through a metallic thermal protection system were obtained using 1-D finite volume thermal analysis, and the resulting displacements of the thermal protection system were calculated. The maximum deflection of the thermal protection system throughout the reentry trajectory was 6.4 mm. The maximum ratio of deflection to boundary layer thickness was 0.032. Based on previously developed distributed roughness correlations, it was concluded that these defections will not result in tripping the hypersonic boundary layer.

  10. Perturbation Training Can Reduce Community-Dwelling Older Adults’ Annual Fall Risk: A Randomized Controlled Trial

    Science.gov (United States)

    Bhatt, Tanvi; Yang, Feng; Wang, Edward

    2014-01-01

    Background. Previous studies indicated that a single session of repeated-slip exposure can reduce over 40% of laboratory-induced falls among older adults. The purpose of this study was to determine to what degree such perturbation training translated to the reduction of older adults’ annual falls risk in their everyday living. Methods. Two hundred and twelve community-dwelling older adults (≥65 years old) were randomly assigned to either the training group (N = 109), who then were exposed to 24 unannounced repeated slips, or the control group (N = 103), who merely experienced one slip during the same walking in the same protective laboratory environment. We recorded their falls in the preceding year (through self-reported history) and during the next 12 months (through falls diary and monitored with phone calls). Results. With this single session of repeated-slip exposure, training cut older adults’ annual risk of falls by 50% (from 34% to 15%, p fall during the same 12-month follow-up period (p falls. Conclusion. A single session of repeated-slip exposure could improve community-dwelling older adults’ resilience to postural disturbances and, hence, significantly reduce their annual risk of falls. PMID:24966227

  11. 78 FR 25406 - Proposed Modification of Class E Airspace; Twin Falls, ID

    Science.gov (United States)

    2013-05-01

    ...) Global Positioning System (GPS) and the Instrument Landing System (ILS) or Localizer (LOC) standard... the earth. * * * * * ANM ID E5 Twin Falls, ID [Modified] Twin Falls Joslin Field-Magic Valley Regional...

  12. Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors

    Directory of Open Access Journals (Sweden)

    Mišák Stanislav

    2017-06-01

    Full Text Available This paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the above mentioned faults was developed. After having tested its operation, the system has already been implemented to protect mediumvoltage overhead lines built of covered conductors.

  13. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  14. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  15. Outer skin protection of columbium Thermal Protection System (TPS) panels

    Science.gov (United States)

    Culp, J. D.

    1973-01-01

    A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.

  16. 44 CFR 65.14 - Remapping of areas for which local flood protection systems no longer provide base flood protection.

    Science.gov (United States)

    2010-10-01

    ... local flood protection systems no longer provide base flood protection. 65.14 Section 65.14 Emergency... § 65.14 Remapping of areas for which local flood protection systems no longer provide base flood... process of restoring a flood protection system that was: (i) Constructed using Federal funds; (ii...

  17. Fall determinants in older long-term care residents with dementia: a systematic review.

    Science.gov (United States)

    Kröpelin, Tobias F; Neyens, Jacques C L; Halfens, Ruud J G; Kempen, Gertrudis I J M; Hamers, Jan P H

    2013-04-01

    Persons with dementia are two to three times more likely to fall compared to persons without dementia. In long-term care settings, the dementia prevalence is highest. Therefore, older long-term care residents with dementia can be considered a high-risk group for falls. Nevertheless, no systematic evaluation of fall determinants in this population was found. The purpose of this study was to identify fall determinants among older long-term care residents with dementia or cognitively impaired persons in long-term care, by conducting a systematic literature review. We searched English, French, Dutch, and German articles listed in: CINAHL, Cochrane Library, EMBASE, MEDLINE, PsycINFO, PubMed, and Web of Science. Additionally, references of included articles were screened. Studies were included if determinants or circumstances of falls in older persons with dementia living in long-term care were assessed. Eight studies met the inclusion criteria. Three studies were excluded from detailed analysis because of insufficient quality. Use of psychotropic drugs, a "fair or poor" general health, gait impairments, and age were associated with an increased fall risk. Also trunk restraints were associated with an increased number of falls while full bedrails and wandering behavior were protective against falls. Fall risk factors known from other populations, e.g. use of psychotropic drugs, physical restraints, and health conditions, are found in long-term care residents with dementia as well. Due to the limited evidence available, future studies with adequate sample sizes and prospective designs are required to determine specific fall risk factors and verify existing results in this population.

  18. New Vaccines Help Protect You

    Science.gov (United States)

    ... Bar Home Current Issue Past Issues New Vaccines Help Protect You Past Issues / Fall 2006 Table of ... with a few deaths. Therefore, this vaccine will help reduce one of our most common and potentially ...

  19. Protective relaying of power systems using mathematical morphology

    CERN Document Server

    Wu, QH; Ji, TY

    2009-01-01

    Discusses the development of novel protective relaying algorithms, using Mathematical Morphology (MM). This book introduces the fundamental principles of MM, and brings together the applications of MM to develop different protective relaying algorithms for the protection of a variety of power system components.

  20. Cloud-Based Smart Health Monitoring System for Automatic Cardiovascular and Fall Risk Assessment in Hypertensive Patients.

    Science.gov (United States)

    Melillo, P; Orrico, A; Scala, P; Crispino, F; Pecchia, L

    2015-10-01

    The aim of this paper is to describe the design and the preliminary validation of a platform developed to collect and automatically analyze biomedical signals for risk assessment of vascular events and falls in hypertensive patients. This m-health platform, based on cloud computing, was designed to be flexible, extensible, and transparent, and to provide proactive remote monitoring via data-mining functionalities. A retrospective study was conducted to train and test the platform. The developed system was able to predict a future vascular event within the next 12 months with an accuracy rate of 84 % and to identify fallers with an accuracy rate of 72 %. In an ongoing prospective trial, almost all the recruited patients accepted favorably the system with a limited rate of inadherences causing data losses (<20 %). The developed platform supported clinical decision by processing tele-monitored data and providing quick and accurate risk assessment of vascular events and falls.

  1. Fusion of Color and Depth Camera Data for Robust Fall Detection

    NARCIS (Netherlands)

    Josemans, W.; Englebienne, G.; Kröse, B.; Battiato, S.; Braz, J.

    2013-01-01

    The availability of cheap imaging sensors makes it possible to increase the robustness of vision-based alarm systems. This paper explores the benefit of data fusion in the application of fall detection. Falls are a common source of injury for elderly people and automatic fall detection is,

  2. Nurses' Perceptions of Implementing Fall Prevention Interventions to Mitigate Patient-Specific Fall Risk Factors.

    Science.gov (United States)

    Wilson, Deleise S; Montie, Mary; Conlon, Paul; Reynolds, Margaret; Ripley, Robert; Titler, Marita G

    2016-08-01

    Evidence-based (EB) fall prevention interventions to mitigate patient-specific fall risk factors are readily available but not routinely used in practice. Few studies have examined nurses' perceptions about both the use of these EB interventions and implementation strategies designed to promote their adoption. This article reports qualitative findings of nurses' perceptions about use of EB fall prevention interventions to mitigate patient-specific fall risks, and implementation strategies to promote use of these interventions. The findings revealed five major themes: before-study fall prevention practices, use of EB fall prevention interventions tailored to patient-specific fall risk factors, beneficial implementation strategies, overall impact on approach to fall prevention, and challenges These findings are useful to guide nurses' engagement and use of EB fall prevention practices tailored to patient-specific fall risk factors. © The Author(s) 2016.

  3. New measuring and protection system at VR-1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Jurickova, M.

    2006-01-01

    The contribution describes the new measuring and protection system of the VR-1 training reactor. The measuring and protection system upgrade is an integral part of the reactor I and C upgrade. The new measuring and protection system of the VR-1 reactor consists of the operational power measuring and the independent power protection systems. Both systems measure the reactor power and power rate, initiate safety action if safety limits are exceeded and send data (power, power rate, status, etc.) to the reactor control system. The operational power measuring system is a full power range system that receives signal from a fission chamber. The signal is evaluated according to the reactor power either in the pulse or current mode. The current mode utilizes the DC current and Campbell techniques. The new independent power protection system operates in the two highest reactor power decades. It receives signals from a boron chamber and evaluates it in the pulse mode. Both systems are computer based. The operational power measuring and independent power protection systems are diverse - different types and location of chambers, completely different hardware, software algorithms for the power and power rate calculations, software development tools and teems for the software manufacturing. (author)

  4. Testing the Predictive Validity of the Hendrich II Fall Risk Model.

    Science.gov (United States)

    Jung, Hyesil; Park, Hyeoun-Ae

    2018-03-01

    Cumulative data on patient fall risk have been compiled in electronic medical records systems, and it is possible to test the validity of fall-risk assessment tools using these data between the times of admission and occurrence of a fall. The Hendrich II Fall Risk Model scores assessed during three time points of hospital stays were extracted and used for testing the predictive validity: (a) upon admission, (b) when the maximum fall-risk score from admission to falling or discharge, and (c) immediately before falling or discharge. Predictive validity was examined using seven predictive indicators. In addition, logistic regression analysis was used to identify factors that significantly affect the occurrence of a fall. Among the different time points, the maximum fall-risk score assessed between admission and falling or discharge showed the best predictive performance. Confusion or disorientation and having a poor ability to rise from a sitting position were significant risk factors for a fall.

  5. Report on task I: fire protection system study

    International Nuclear Information System (INIS)

    Bernard, E.A.; Cano, G.L.

    1977-02-01

    This study (1) evaluates, on a comparative basis, the national and international regulatory and insurance standards that serve as guidance for fire protection within the nuclear power industry; (2) analyzes the recommendations contained in the major reports on the Browns Ferry Fire; (3) proposes quantitative safety goals and evaluation methods for Nuclear Power Plant Fire Protection Systems (NPPFPS); (4) identifies potential improvements that may be incorporated into NPPFPS; and (5) recommends a plan of action for continuation of the fire protections systems study

  6. Illustration of distributed generation effects on protection system coordination

    Science.gov (United States)

    Alawami, Hussain Adnan

    Environmental concerns, market forces, and emergence of new technologies have recently resulted in restructuring electric utility from vertically integrated networks to competitive deregulated entities. Distributed generation (DG) is playing a major role in such deregulated markets. When they are installed in small amounts and small sizes, their impacts on the system may be negligible. When their penetration levels increase as well as their sizes, however, they may start affecting the system performance from more than one aspect. Power system protection needs to be re-assessed after the emergence of DG. This thesis attempts to illustrate the impact of DG on the power system protection coordination. It will study the operation of the impedance relays, fuses, reclosers and overcurrent relays when a DG is added to the distribution network. Different DG sizes, distances from the network and locations within the distribution system will be considered. Power system protection coordination is very sensitive to the DG size where it is not for the DG distance. DG location has direct impact on the operation of the protective devices especially when it is inserted in the middle point of the distribution system. Key Words, Distributed Generation, Impedance relay, fuses, reclosers, overcurrent relays, power system protection coordination.

  7. STEADI: CDC's approach to make older adult fall prevention part of every primary care practice.

    Science.gov (United States)

    Sarmiento, Kelly; Lee, Robin

    2017-12-01

    Primary care providers play a critical role in protecting older adult patients from one of the biggest threats to their health and independence-falls. A fall among an older adult patient cannot only be fatal or cause a devastating injury, but can also lead to problems that can effect a patient's overall quality of life. In response, the Centers for Disease Control and Prevention (CDC) developed the STEADI initiative to give health care providers the tools they need to help reduce their older adult patient's risk of a fall. CDC's STEADI resources have been distributed widely and include practical materials and tools for health care providers and their patients that are designed to be integrated into every primary care practice. As the population ages, the need for fall prevention efforts, such as CDC's STEADI, will become increasingly critical to safeguard the health of Americans. STEADI's electronic health records (EHRs), online trainings, assessment tools, and patient education materials are available at no-cost and can be downloaded online at www.cdc.gov/STEADI. Health care providers should look for opportunities to integrate STEADI materials into their practice, using a team-based approach, to help protect their older patients. Published by Elsevier Ltd.

  8. An integrated numerical protection system (SPIN)

    International Nuclear Information System (INIS)

    Savornin, J.L.; Bouchet, J.M.; Furet, J.L.; Jover, P.; Sala, A.

    1978-01-01

    Developments in technology have now made it possible to perform more sophisticated protection functions which follow more closely the physical phenomena to be monitored. For this reason the Commissariat a l'energie atomique, Merlin-Gerin, Cerci and Framatome have embarked on the joint development of an Integrated Numerical Protection System (SPIN) which will fulfil this objective and will improve the safety and availability of power stations. The system described involves the use of programmed numerical techniques and a structure based on multiprocessors. The architecture has a redundancy of four. Throughout the development of the project the validity of the studies was confirmed by experiments. A first numerical model of a protection function was tested in the laboratory and is now in operation in a power station. A set of models was then introduced for checking the main components of the equipment finally chosen prior to building and testing a prototype. (author)

  9. Preventing falls and fractures.

    Science.gov (United States)

    Ulfarsson, J; Robinson, B E

    1994-11-01

    One of four persons over age 65 in the community falls; those over age 75 in institutions fall more frequently. Falls, a complex phenomena suggesting present disease and predicting future disability, are caused by interactions between the environment and dynamic balance which is determined by the quality of sensory input, central processing, and motor responses. Clinical factors which predispose to falling often produce observable disturbances in gait and balance, making observation critical in assessment. Acute illness and drug therapy produce particularly preventable falls. Therapeutic exercise and environmental modification for safety are the clinical interventions most likely to successfully prevent fall-related injury.

  10. A Successful ED Fall Risk Program Using the KINDER 1 Fall RiskAssessment Tool.

    Science.gov (United States)

    Townsend, Ann B; Valle-Ortiz, Marisol; Sansweet, Tracy

    2016-11-01

    Emergency nurses did not perform falls risk assessments routinely on our ED patients; the instrument used was aimed at inpatients. We identified a need to revise fall assessment practices specific to our emergency department. The purpose of the performance improvement project was to reduce ED falls and evaluate the use of an ED-specific fall risk tool, the KINDER 1 Fall Risk Assessment. The plan was to establish fall risk assessment practices at point of ED entry and to decrease total falls. We retrospectively reviewed ED fall data for each quarter of 2013, which included risk assessments scores, the total number of falls, and the circumstances of each fall. Using Kotter's framework to guide a successful change process, we implemented the KINDER 1 to assess fall risk. During the first 4 weeks of the project, 937 patients (27%) were identified as high risk for falls using the KINDER 1. During the subsequent 3 quarters, the total number of falls decreased; reported falls without injuries dropped from 0.21 to 0.07 per 1000 patients, and falls with injuries were reduced from 0.21 to 0.0 per 1000 patients. The results of this project represented a valuable step toward achieving our goal to keep ED patients safe from injuries as a result of falls. The findings add to the body of nursing knowledge on the application of clinical-based performance improvement projects to improve patient outcomes and to provide data on the use of the KINDER 1 tool, which has not been extensively tested. Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  11. SNAP: a tool for nuclear physical protection system modeling

    International Nuclear Information System (INIS)

    Engi, D.; Grant, F.H. III.

    1979-10-01

    Nuclear safeguards systems are concerned, in part, with the physical protection of nuclear materials. The function of a physical protection system is to define the facility against adversary activities which could lead to theft of nuclear material or sabotage resulting in a radiological release. The Safeguards Network Analysis Procedure (SNAP) provides a convenient and standard analysis methodology for the evaluation of physical protection system analysis. This paper describes a detailed application of SNAP to a hypothetical nuclear facility

  12. Development of In-Core Protection System

    International Nuclear Information System (INIS)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H.

    2016-01-01

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project

  13. Development of In-Core Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H. [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project.

  14. 'H-Bahn' - Dortmund demonstration system. Automatic vehicle protection system

    Energy Technology Data Exchange (ETDEWEB)

    Rosenkranz

    1984-01-01

    The automatic vehicle protection system of the H-Bahn at the Universtiy of Dortmund is responsible for fail-safe operating of the automatic vehicles. Its functions are protection of vehicle operation and protection of passengers boarding and leaving the vehicles. These functions are managed decentrally by two fail-safe operating controllers. Besides the well-known relay-techniques of railway-fail-safe systems, electronics are applied which are based on safe operating URTL-microcontrollers. These are controlled by software stored in EPROMs. A connection link using glass-fibres serves for safe data-exchange between the two fail-safe operating controllers. The experts' favourable reports on 'train protection and safety during passenger processing' were completed in March 84; thus, transportation of passengers could start in April 84.

  15. Predictive value of stabilometry and fear of falling on falls in postmenopausal women.

    Science.gov (United States)

    Hita-Contreras, F; Martínez-Amat, A; Lomas-Vega, R; Álvarez, P; Aránega, A; Martínez-López, E; Mendoza, N

    2013-10-01

    Falls are one of the leading causes of fractures and impaired quality of life in the elderly, and they are related to balance deficit and to fear of falls. The purpose of our study is to evaluate predictors of falls in the 50-65-year-old postmenopausal population. A prospective cohort study was conducted on 96 postmenopausal women. Fear of falling and postural stability were assessed by using the FES-I (Falls Efficacy Scale-International) and a force platform, respectively. Fall frequency was determined in the 12-month follow-up study period. Multivariate logistic regression was used to identify predictive factors of falls. Fear of falls, the FES-I scale and four stabilometric parameters, specifically under eyes-closed condition, were significantly higher in the group of fallers. The root mean square amplitude in the medial-lateral direction with eyes closed (RMSXec) (odds ratio 5.1, 95% confidence interval (CI) 1.6-15.5, p = 0.004) and FES-I (odds ratio 3.4, 95% CI 1.1-10.5, p = 0.026) were the best independent predictive factors of the risk of falling. RMSXec > 0.133 was the best predictive factor for falls in our group of 50-65-year-old postmenopausal women studied, and a FES-I score > 20 could predict falls in this population.

  16. Effects of falls prevention interventions on falls outcomes for hospitalised adults: protocol for a systematic review with meta-analysis.

    Science.gov (United States)

    Slade, Susan C; Carey, David L; Hill, Anne-Marie; Morris, Meg E

    2017-11-12

    Falls are a major global public health problem and leading cause of accidental or unintentional injury and hospitalisation. Falls in hospital are associated with longer length of stay, readmissions and poor outcomes. Falls prevention is informed by knowledge of reversible falls risk factors and accurate risk identification. The extent to which hospital falls are prevented by evidence-based practice, patient self-management initiatives, environmental modifications and optimisation of falls prevention systems awaits confirmation. Published reviews have mainly evaluated community settings and residential care facilities. A better understanding of hospital falls and the most effective strategies to prevent them is vital to keeping people safe. To evaluate the effectiveness of falls prevention interventions on reducing falls in hospitalised adults (acute and subacute wards, rehabilitation, mental health, operating theatre and emergency departments). We also summarise components of effective falls prevention interventions. This protocol has been registered. The systematic review will be informed by Cochrane guidelines and reported according to the Preferred Reporting Items for Systematic review and Meta-Analysis statement. randomised controlled trials, quasi-randomised trials or controlled clinical trials that evaluate falls prevention interventions for use by hospitalised adults or employees. Electronic databases will be searched using key terms including falls, accidental falls, prevention, hospital, rehabilitation, emergency, mental health, acute and subacute. Pairs of independent reviewers will conduct all review steps. Included studies will be evaluated for risk of bias. Data for variables such as age, participant characteristics, settings and interventions will be extracted and analysed with descriptive statistics and meta-analysis where possible. The results will be presented textually, with flow charts, summary tables, statistical analysis (and meta

  17. Systems and methods for photovoltaic string protection

    Science.gov (United States)

    Krein, Philip T.; Kim, Katherine A.; Pilawa-Podgurski, Robert C. N.

    2017-10-25

    A system and method includes a circuit for protecting a photovoltaic string. A bypass switch connects in parallel to the photovoltaic string and a hot spot protection switch connects in series with the photovoltaic string. A first control signal controls opening and closing of the bypass switch and a second control signal controls opening and closing of the hot spot protection switch. Upon detection of a hot spot condition the first control signal closes the bypass switch and after the bypass switch is closed the second control signal opens the hot spot protection switch.

  18. Numerical simulation and experimental results of horizontal tube falling film generator working in a NH3-LiNO3 absorption refrigeration system

    International Nuclear Information System (INIS)

    Herrera, J.V.; Garcia-Valladares, O.; Gomez, V.H.; Best, R.

    2010-01-01

    This paper describes the work made at the Centro de Investigacion en Energia in the development of an absorption refrigeration system for cooling and refrigeration applications with a capacity of 10 kW. The single effect unit utilizes ammonia-lithium nitrate as working pair and it is air cooled. The generator is a falling film type with horizontal tubes where the heating oil flows inside the tube bank and the ammonia-lithium nitrate solution flows as a falling film on the tube outside, where it is heated and ammonia vapor is generated. The generator consists of tree columns and four rows per column of horizontal tubes. The system was tested at controlled conditions with heating oil obtained from an electric resistance heating loop. A numerical model of the horizontal falling film generator was developed that divided the system into three different thermal elements: the flow inside the tube, the heat conduction in the tube wall and the falling film solution flow. The mathematical model was tested and validated with experimental data and a study of the influence of the heat transfer coefficient for ammonia-lithium nitrate solution in the numerical model was carried out. A comparison between experimental and numerical data for the heat flux in the system and the temperature profiles in the oil and solution flows shown a good degree of correlation.

  19. Preventive Effects of Safety Helmets on Traumatic Brain Injury after Work-Related Falls

    Directory of Open Access Journals (Sweden)

    Sang Chul Kim

    2016-10-01

    Full Text Available Introduction: Work-related traumatic brain injury (TBI caused by falls is a catastrophic event that leads to disabilities and high socio-medical costs. This study aimed to measure the magnitude of the preventive effect of safety helmets on clinical outcomes and to compare the effect across different heights of fall. Methods: We collected a nationwide, prospective database of work-related injury patients who visited the 10 emergency departments between July 2010 and October 2012. All of the adult patients who experienced work-related fall injuries were eligible, excluding cases with unknown safety helmet use and height of fall. Primary and secondary endpoints were intracranial injury and in-hospital mortality. We calculated adjusted odds ratios (AORs of safety helmet use and height of fall for study outcomes, and adjusted for any potential confounders. Results: A total of 1298 patients who suffered from work-related fall injuries were enrolled. The industrial or construction area was the most common place of fall injury occurrence, and 45.0% were wearing safety helmets at the time of fall injuries. The safety helmet group was less likely to have intracranial injury comparing with the no safety helmet group (the adjusted odds ratios (ORs (95% confidence interval (CI: 0.42 (0.24–0.73, however, there was no statistical difference of in-hospital mortality between two groups (the adjusted ORs (95% CI: 0.83 (0.34–2.03. In the interaction analysis, preventive effects of safety helmet on intracranial injury were significant within 4 m height of fall. Conclusions: A safety helmet is associated with prevention of intracranial injury resulting from work-related fall and the effect is preserved within 4 m height of fall. Therefore, wearing a safety helmet can be an intervention for protecting fall-related intracranial injury in the workplace.

  20. Architecture and Fault Identification of Wide-area Protection System

    Directory of Open Access Journals (Sweden)

    Yuxue Wang

    2012-09-01

    Full Text Available Wide-area protection system (WAPS is widely studied for the purpose of improvng the performance of conventional backup protection. In this paper, the system architecture of WAPS is proposed and its key technologies are discussed in view of engineering projects. So a mixed structurecentralized-distributed structure which is more suitable for WAPS in limited power grid region, is obtained based on the advantages of the centralized structure and distributed structure. Furthermore, regional distance protection algorithm was taken as an example to illustrate the functions of the constituent units. Faulted components can be detected based on multi-source imformation fuse in the algorithm. And the algorithm cannot only improve the selectivity, the rapidity, and the reliability of relaying protection but also has high fault tolerant capability. A simulation of 220 kV grid systems in Easter Hubei province shows the effectiveness of the wide-area protection system presented by this paper.

  1. A critical review of the system of radiation protection

    International Nuclear Information System (INIS)

    2000-01-01

    Our modern, information society is increasingly interested in transparency and participation in many aspects of government, and this is particularly true in areas involving public health and environmental protection. Radiation protection is no exception to this trend. Scientific rationale that was once sufficient to explain radiation protection theory and practice is no longer adequate. The need to address and communicate theory, practice and the decision-making process to a wider audience has given rise to numerous debates and led the radiation protection community to revisit the framework of the system of radiation protection. The very fundamentals of the system of radiation protection continue to be questioned in a healthy fashion, and many aspects have been identified which could better serve stakeholders given some additional thought in the light of modern societal needs. This report is the summary of the NEA's first reflections in this area, and describes those aspects of the current international system of radiation protection that could be improved. Suggested directions for improvement are provided. (author)

  2. Dependability Evaluation of Advanced Diverse Protection System

    International Nuclear Information System (INIS)

    Oh, Yang Gyun; Lee, Yoon Hee; Sohn, Se Do; Baek, Seung Min; Lee, Sang Jeong

    2014-01-01

    For the mitigation of anticipated transients without scram (ATWS) as well as common cause failure (CCF) within the plant protection system (PPS) and the emergency safety feature . component control system (ESF-CCS), the diverse protection system (DPS) has been designed by KEPCO Engineering and Construction Company. Recently KEPCO E and C has developed the advanced diverse protection system (ADPS), which has four redundant channels, in an attempt to enhance a fault-tolerant capability of the system. For the evaluation of overall system improvement effects of the ADPS compared with the DPS, the dependability evaluation results are described herein. For all dependability attributes, this paper suggests a practical dependability evaluation method which uses quantitative dependability scores and indices. An overall dependability evaluation index (DEI) for the ADPS is evaluated with the average value of reliability/ security/maintainability/safety indices (i.e., RID, SID, MID, and SID') for dependability. The evaluation results show that the DEI value of ADPS can be improved by approximately 23% compared with that of the DPS, thanks to its fault-tolerant system architecture, software design changes, and external interface design features. Several suggestions have been made, in this paper, of an overall quantitative dependability evaluation method for the nuclear instrumentation and control (I and C) systems including the DPS and ADPS, and the usefulness of dependability evaluation on nuclear I and C systems has been confirmed

  3. Falls in institutions for older adults: characterization of fall occurrences and associated risk factors

    Directory of Open Access Journals (Sweden)

    Cristina Rosa Soares Lavareda Baixinho

    2015-12-01

    Full Text Available Falls are the main accident for older adults, with consequences on functionality. Older adults impose restrictions or have restrictions imposed on their activities for fear of new falls. This prospective longitudinal study was conducted with 104 institutionalized older adults during six months with the following goals: to determine the prevalence of falls, to characterize the falls according to place, time, resulting injuries, supervision of the older adult, action performed at the time of the fall, and to relate the occurrence of the fall to the risk of falling, medical diagnoses, number of medications in use, type of medication, degree of dependency, age, and gender. The prevalence of falls was 37.5%, and they happened mostly in the bedroom, while walking after getting up from the bed. Those under risk in the Morse Fall Scale (p=0.034 and on sedatives (p=0.007 face a higher prevalence of falls. This study enables the possibility of making suggestions for practice, training and investigation.

  4. The Neighborhood Environment: Perceived Fall Risk, Resources, and Strategies for Fall Prevention.

    Science.gov (United States)

    Chippendale, Tracy; Boltz, Marie

    2015-08-01

    To explore the experience of older adults in their neighborhood in relation to perceived fall risk, fear of falling (FOF), and resources/strategies for fall prevention. Fourteen older adults, 65 years of age and older from 3 urban senior centers, participated in this qualitative study. The semistructured interview guidelines and background questionnaire were developed by the researchers based on the literature and an existing measure of walkability. Both tools were refined based on pilot interviews with seniors. Collaizzi's phenomenological method was used for data analysis. Five themes emerged from the data: (a) The built environment contributes to perceived fall risk and FOF, (b) personal strategies used to adapt to perceived neighborhood fall risks-behavioral approaches, (c) resources for physical activity and safety, (d) barriers to physical activity and exercise, and (e) neighborhood features as a motivator. Urban-dwelling seniors perceive that neighborhood features contribute to or mitigate fall risk and FOF. Behavioral strategies are used by seniors to prevent outdoor falls. The findings can help clinicians develop targeted fall prevention interventions for well elders and help urban planners to design and retrofit urban environments to reduce fall risk. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Equivalence principle for quantum systems: dephasing and phase shift of free-falling particles

    Science.gov (United States)

    Anastopoulos, C.; Hu, B. L.

    2018-02-01

    We ask the question of how the (weak) equivalence principle established in classical gravitational physics should be reformulated and interpreted for massive quantum objects that may also have internal degrees of freedom (dof). This inquiry is necessary because even elementary concepts like a classical trajectory are not well defined in quantum physics—trajectories originating from quantum histories become viable entities only under stringent decoherence conditions. From this investigation we posit two logically and operationally distinct statements of the equivalence principle for quantum systems. Version A: the probability distribution of position for a free-falling particle is the same as the probability distribution of a free particle, modulo a mass-independent shift of its mean. Version B: any two particles with the same velocity wave-function behave identically in free fall, irrespective of their masses. Both statements apply to all quantum states, including those without a classical correspondence, and also for composite particles with quantum internal dof. We also investigate the consequences of the interaction between internal and external dof induced by free fall. For a class of initial states, we find dephasing occurs for the translational dof, namely, the suppression of the off-diagonal terms of the density matrix, in the position basis. We also find a gravitational phase shift in the reduced density matrix of the internal dof that does not depend on the particle’s mass. For classical states, the phase shift has a natural classical interpretation in terms of gravitational red-shift and special relativistic time-dilation.

  6. A simple fall detection algorithm for Powered Two Wheelers

    OpenAIRE

    BOUBEZOUL, Abderrahmane; ESPIE, Stéphane; LARNAUDIE, Bruno; BOUAZIZ, Samir

    2013-01-01

    The aim of this study is to evaluate a low-complexity fall detection algorithm, that use both acceleration and angular velocity signals to trigger an alert-system or to inflate an airbag jacket. The proposed fall detection algorithm is a threshold-based algorithm, using data from 3-accelerometers and 3-gyroscopes sensors mounted on the motorcycle. During the first step, the commonly fall accident configurations were selected and analyzed in order to identify the main causation factors. On the...

  7. The protection of photovoltaic power systems from lightning

    Science.gov (United States)

    Rogers, C. B.

    Lightning protection techniques at nine prototype photovoltaic power system sites with outputs from 18-225 kW are described. Noting that protection schemes are devised to fit isokeraunic data for specific sites, grounding is cited as a common feature for all systems. The grounds are, in separate instances, connected to junction boxes, frames of the solar cell panels, lead from the dc center, from the dc negative terminal, from the frames and equipment, at the array turntable, or from the building rebar frames. The dc power cables are protected by either metal conduit, metal conduit ground wire, direct burial, by rigid metal conduit, ground conductors, or by ground conductors at the ends of the conduit run. Costs run from 0.01-0.28$/W, with all the systems outfitted with bypass and blocking diodes. Direct stroke protection is viewed as less important than isokeraunic data.

  8. Intelligent transportation system (ITS) study for the Buffalo and Niagara Falls metropolitan area, Erie and Niagara Counties, New York : functional requirements, working paper #4

    Science.gov (United States)

    1997-06-18

    This paper is the fourth in a series that together will comprise an Intelligent Transportation System (ITS) Study for the Buffalo / Niagara Falls region. This document presents the market packages for the deployment of the Buffalo/Niagara Falls area ...

  9. Wearable Fall Detector using Integrated Sensors and Energy Devices

    Science.gov (United States)

    Jung, Sungmook; Hong, Seungki; Kim, Jaemin; Lee, Sangkyu; Hyeon, Taeghwan; Lee, Minbaek; Kim, Dae-Hyeong

    2015-11-01

    Wearable devices have attracted great attentions as next-generation electronic devices. For the comfortable, portable, and easy-to-use system platform in wearable electronics, a key requirement is to replace conventional bulky and rigid energy devices into thin and deformable ones accompanying the capability of long-term energy supply. Here, we demonstrate a wearable fall detection system composed of a wristband-type deformable triboelectric generator and lithium ion battery in conjunction with integrated sensors, controllers, and wireless units. A stretchable conductive nylon is used as electrodes of the triboelectric generator and the interconnection between battery cells. Ethoxylated polyethylenimine, coated on the surface of the conductive nylon electrode, tunes the work function of a triboelectric generator and maximizes its performance. The electrical energy harvested from the triboelectric generator through human body motions continuously recharges the stretchable battery and prolongs hours of its use. The integrated energy supply system runs the 3-axis accelerometer and related electronics that record human body motions and send the data wirelessly. Upon the unexpected fall occurring, a custom-made software discriminates the fall signal and an emergency alert is immediately sent to an external mobile device. This wearable fall detection system would provide new opportunities in the mobile electronics and wearable healthcare.

  10. Characteristics and fall experiences of older adults with and without fear of falling outdoors.

    Science.gov (United States)

    Chippendale, Tracy; Lee, Chang Dae

    2018-06-01

    Using a theoretical model that combines an ecological perspective and Bandura's theory of self-efficacy as a guide, we sought to compare experiences and characteristics of community dwelling older adults with and without concern about falling outdoors. A survey of randomly selected community dwelling older adults across NYC (N = 120) was conducted using the outdoor falls questionnaire. Descriptive quantitative analyses of participant characteristics were conducted for all participants and for those with and without concern about falling outside. Conventional content analysis using two coders was employed to examine outdoor fall experiences for each group. A mixed methods matrix was used to integrate qualitative and quantitative findings. Some participant characteristics were more common among those with a concern about falling outside such as decreased functional status, female gender, and number of prior outdoor falls. As per descriptions of outdoor fall experiences, participants with concern were more likely to report a fall while climbing stairs or stepping up a curb, describe an intrinsic factor as a cause of their fall, use an injury prevention strategy during the fall, sustain a moderate to severe injury, seek medical attention, have had an ambulance called, require help to get up, and describe implementation of a behavioral change after the fall. Differences exist in participant characteristics and outdoor fall experiences of those with and without concern about falling outside. The proposed model can be used to understand fear of falling outdoors and can help to inform the target population and content of intervention programs.

  11. Pathogenesis and treatment of falls in elderly

    Science.gov (United States)

    Pasquetti, Pietro; Apicella, Lorenzo; Mangone, Giuseppe

    2014-01-01

    Summary Falls in the elderly are a public health problem. Consequences of falls are increased risk of hospitalization, which results in an increase in health care costs. It is estimated that 33% of individuals older than 65 years undergoes falls. Causes of falls can be distinguished in intrinsic and extrinsic predisposing conditions. The intrinsic causes can be divided into age-related physiological changes and pathological predisposing conditions. The age-related physiological changes are sight disorders, hearing disorders, alterations in the Central Nervous System, balance deficits, musculoskeletal alterations. The pathological conditions can be Neurological, Cardiovascular, Endocrine, Psychiatric, Iatrogenic. Extrinsic causes of falling are environmental factors such as obstacles, inadequate footwear. The treatment of falls must be multidimensional and multidisciplinary. The best instrument in evaluating elderly at risk is Comprehensive Geriatric Assessment (CGA). CGA allows better management resulting in reduced costs. The treatment should be primarily preventive acting on extrinsic causes; then treatment of chronic and acute diseases. Rehabilitation is fundamental, in order to improve residual capacity, motor skills, postural control, recovery of strength. There are two main types of exercises: aerobic and muscular strength training. Education of patient is a key-point, in particular through the Back School. In conclusion falls in the elderly are presented as a “geriatric syndrome”; through a multidimensional assessment, an integrated treatment and a rehabilitation program is possible to improve quality of life in elderly. PMID:25568657

  12. The functional assessment Berg Balance Scale is better capable of estimating fall risk in the elderly than the posturographic Balance Stability System.

    Science.gov (United States)

    Pereira, Vanessa Vieira; Maia, Roberto Alcantara; Silva, Sonia Maria Cesar de Azevedo

    2013-01-01

    The purpose of this study was to verify which instrument better identifies recurrent falls in the elderly. Ninety-eight old people, with an average age of 80 ± 4 years, were submitted to an assessment of balance and fall risk by means of the Berg Balance Scale (BBS) and the posturographic Balance Stability System (BSS). The BBS was correlated with the BSS (r=-0.27; p=0.008), age (r=-0.38; pfalls (r=-0.25; p=0.013) and the analysis of logistical regression showed that the elderly classified with fall risk on the BBS presented 2.5 (95%CI 1.08-5.78) more chance of identifying who had two falls or more over the last year. The BBS identified that the greater the age the worse the functional balance and demonstrated a greater capacity to identify falls risk suffered over the last year when compared with the BSS.

  13. Incidence of falls and preventive actions in a University Hospital.

    Science.gov (United States)

    Luzia, Melissa de Freitas; Cassola, Talita Portela; Suzuki, Lyliam Midori; Dias, Vera Lucia Mendes; Pinho, Leandro Barbosa de; Lucena, Amália de Fátima

    2018-01-01

    Objective Describing the incidence of falls and its relation with preventive actions developed in a Brazilian university hospital. Method A retrospective longitudinal study. Hospitalized adult patients in the clinical, surgical, psychiatric and emergency units who suffered a fall in the institution, and who had the event notified in the period from January 2011 to December 2015 were included in the study. The data were collected from the institution's management information system and analyzed in the SPSS statistical program. Results There were 2,296 falls, with a mean incidence of 1.70 falls/1,000 patients per day. An increase in the incidence of falls was observed in the period from 2011 (1.61) to 2012 (2.03). In the following years, the incidence of falls decreased from 1.83 falls/1,000 patients per day in 2013 to 1.42 falls/1,000 patients per day in 2015. The incidence of falls accompanied an implementation of preventive actions, suggesting the impact of such interventions in reducing the event occurrence. Conclusion The findings demonstrate the importance of implementing preventive interventions in reducing the incidence of falls in hospitalized patients.

  14. Postural balance and the risk of falling during pregnancy.

    Science.gov (United States)

    Cakmak, Bulent; Ribeiro, Ana Paula; Inanir, Ahmet

    2016-01-01

    Pregnancy is a physiological process and many changes occur in a woman's body during pregnancy. These changes occur in all systems to varying degrees, including the cardiovascular, respiratory, genitourinary, and musculoskeletal systems. The hormonal, anatomical, and physiological changes occurring during pregnancy result in weight gain, decreased abdominal muscle strength and neuromuscular control, increased ligamentous laxity, and spinal lordosis. These alterations shift the centre of gravity of the body, altering the postural balance and increasing the risk of falls. Falls during pregnancy can cause maternal and foetal complications, such as maternal bone fractures, head injuries, internal haemorrhage, abruption placenta, rupture of the uterus and membranes, and occasionally maternal death or intrauterine foetal demise. Preventative strategies, such as physical exercise and the use of maternity support belts, can increase postural stability and reduce the risk of falls during pregnancy. This article reviews studies that have investigated changes in postural balance and risk of falling during pregnancy.

  15. Effects of a multifactorial fall prevention program on fall incidence and physical function in community-dwelling older adults with risk of falls.

    Science.gov (United States)

    Lee, Hsuei-Chen; Chang, Ku-Chou; Tsauo, Jau-Yih; Hung, Jen-Wen; Huang, Yu-Ching; Lin, Sang-I

    2013-04-01

    To evaluate effects of a multifactorial fall prevention program on fall incidence and physical function in community-dwelling older adults. Multicenter randomized controlled trial. Three medical centers and adjacent community health centers. Community-dwelling older adults (N=616) who have fallen in the previous year or are at risk of falling. After baseline assessment, eligible subjects were randomly allocated into the intervention group (IG) or the control group (CG), stratified by the Physiological Profile Assessment (PPA) fall risk level. The IG received a 3-month multifactorial intervention program including 8 weeks of exercise training, health education, home hazards evaluation/modification, along with medication review and ophthalmology/other specialty consults. The CG received health education brochures, referrals, and recommendations without direct exercise intervention. Primary outcome was fall incidence within 1 year. Secondary outcomes were PPA battery (overall fall risk index, vision, muscular strength, reaction time, balance, and proprioception), Timed Up & Go (TUG) test, Taiwan version of the International Physical Activity Questionnaire, EuroQol-5D, Geriatric Depression Scale (GDS), and the Falls Efficacy Scale-International at 3 months after randomization. Participants were 76±7 years old and included low risk 25.6%, moderate risk 25.6%, and marked risk 48.7%. The cumulative 1-year fall incidence was 25.2% in the IG and 27.6% in the CG (hazard ratio=.90; 95% confidence interval, .66-1.23). The IG improved more favorably than the CG on overall PPA fall risk index, reaction time, postural sway with eyes open, TUG test, and GDS, especially for those with marked fall risk. The multifactorial fall prevention program with exercise intervention improved functional performance at 3 months for community-dwelling older adults with risk of falls, but did not reduce falls at 1-year follow-up. Fall incidence might have been decreased simultaneously in both

  16. 78 FR 30870 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2013-05-23

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: National Marine Protected...) invited federal, state, commonwealth, and territorial marine protected area (MPA) programs with... of Marine Protected Areas of the United States (Framework), developed in response to Executive Order...

  17. System architecture for microprocessor based protection system

    International Nuclear Information System (INIS)

    Gallagher, J.M. Jr.; Lilly, G.M.

    1976-01-01

    This paper discusses the architectural design features to be employed by Westinghouse in the application of distributed digital processing techniques to the protection system. While the title of the paper makes specific reference to microprocessors, this is only one (and the newest) of the building blocks which constitutes a distributed digital processing system. The actual system structure (as realized through utilization of the various building blocks) is established through considerations of reliability, licensability, and cost. It is the intent of the paper to address these considerations licenstions as they relate to the architectural design features. (orig.) [de

  18. Predicting falls using two instruments (the Hendrich Fall Risk Model and the Morse Fall Scale) in an acute care setting in Lebanon.

    Science.gov (United States)

    Nassar, Nada; Helou, Nancy; Madi, Chantal

    2014-06-01

    To assess the predictive value of two instruments (the Morse Fall Scale (MFS) and the Heindrich II Fall Risk Model (HFRM)] in a Middle Eastern country (Lebanon) and to evaluate the factors that are related to falls. A prospective observational cross-sectional design was used. Falls and fall-related injuries in the acute care settings contribute a substantial health and economic burden on patients and organisations. Preventing falls is a priority for most healthcare organisations. While the risk of falling cannot be eliminated, it can be significantly reduced through accurate assessment of patients' risk of falling. Data from 1815 inpatients at the American University of Beirut Medical Center (AUBMC) in Lebanon were evaluated using two instruments to predict falls: the MFS and the HFRM. The incidence of falls was 2·7% in one year. The results indicate that while the instruments were significantly correlated, the HFRM was more sensitive in predicting falls than the MFS. The internal consistency of both scales was moderate, but inter-rater reliability was high. Patients using antiepileptic drugs and assistance devises had higher odds of falling. Although both instruments were easy to use in a Middle Eastern country, the HFRM rather than the MFS is recommended for inpatients in an acute care setting as it had higher sensitivity and specificity. It is recommended that while the HFRM had adequate sensitivity, it is not seamless, and as such, nurses should not rely entirely on it. Rather, nurses should use their expert clinical judgement, their ethical obligations and cultural considerations to implement a safer environment of care for the patient. © 2013 John Wiley & Sons Ltd.

  19. Fall Enrollment Report. 2014

    Science.gov (United States)

    Iowa Department of Education, 2014

    2014-01-01

    This report summarizes and analyzes fall enrollment in Iowa's community colleges. Each year, Iowa's 15 community colleges submit data on enrollment on the 10th business day of the fall semester. Some highlights from this report include: (1) Fall 2014 enrollment was 93,772 students--a decline of 0.49 percent from last fall; (2) Enrollment continues…

  20. Falling Down on the Job: Evaluation and Treatment of Fall Risk Among Older Adults With Upper Extremity Fragility Fractures.

    Science.gov (United States)

    McDonough, Christine M; Colla, Carrie H; Carmichael, Donald; Tosteson, Anna N A; Tosteson, Tor D; Bell, John-Erik; Cantu, Robert V; Lurie, Jonathan D; Bynum, Julie P W

    2017-03-01

    Clinical practice guidelines recommend fall risk assessment and intervention for older adults who sustain a fall-related injury to prevent future injury and mobility decline. The aim of this study was to describe how often Medicare beneficiaries with upper extremity fracture receive evaluation and treatment for fall risk. Observational cohort. Participants were fee-for-service beneficiaries age 66 to 99 treated as outpatients for proximal humerus or distal radius/ulna ("wrist") fragility fractures. -Participants were studied using Carrier and Outpatient Hospital files. The proportion of patients evaluated or treated for fall risk up to 6 months after proximal humerus or wrist fracture from 2007-2009 was examined based on evaluation, treatment, and diagnosis codes. Time to evaluation and number of treatment sessions were calculated. Logistic regression was used to analyze patient characteristics that predicted receiving evaluation or treatment. Narrow (gait training) and broad (gait training or therapeutic exercise) definitions of service were used. There were 309,947 beneficiaries who sustained proximal humerus (32%) or wrist fracture (68%); 10.7% received evaluation or treatment for fall risk or gait issues (humerus: 14.2%; wrist: 9.0%). Using the broader definition, the percentage increased to 18.5% (humerus: 23.4%; wrist: 16.3%). Factors associated with higher likelihood of services after fracture were: evaluation or treatment for falls or gait prior to fracture, more comorbidities, prior nursing home stay, older age, humerus fracture (vs wrist), female sex, and white race. Claims analysis may underestimate physician and physical therapist fall assessments, but it is not likely to qualitatively change the results. A small proportion of older adults with upper extremity fracture received fall risk assessment and treatment. Providers and health systems must advance efforts to provide timely evidence-based management of fall risk in this population. © 2017

  1. Passive fire building protection system evaluation (case study: millennium ict centre)

    Science.gov (United States)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  2. Students fall for Fall Meeting

    Science.gov (United States)

    Smedley, Kara

    2012-02-01

    From Boston to Beijing, thousands of students traveled to San Francisco for the 2011 AGU Fall Meeting. Of those who participated, 183 students were able to attend thanks to AGU's student travel grant program, which assists students with travel costs and seeks to enrich the meeting through ethnic and gender diversity. Students at Fall Meeting enjoyed a variety of programs and activities designed to help them better network with their peers, learn about new fields, and disseminate their research to the interested public. More than 800 students attended AGU's first annual student mixer, sharing drinks and ideas with fellow student members and future colleagues as well as forging new friendships and intellectual relationships.

  3. Social marketing to plan a fall prevention program for Latino construction workers.

    Science.gov (United States)

    Menzel, Nancy N; Shrestha, Pramen P

    2012-08-01

    Latino construction workers experience disparities in occupational death and injury rates. The Occupational Safety and Health Administration funded a fall prevention training program at the University of Nevada, Las Vegas in response to sharp increases in fall-related accidents from 2005 to 2007. The grant's purpose was to improve fall protection for construction workers, with a focus on Latinos. This study assessed the effectiveness of social marketing for increasing fall prevention behaviors. A multi-disciplinary team used a social marketing approach to plan the program. We conducted same day class evaluations and follow-up interviews 8 weeks later. The classes met trainee needs as evidenced by class evaluations and increased safety behaviors. However, Spanish-speaking Latinos did not attend in the same proportion as their representation in the Las Vegas population. A social marketing approach to planning was helpful to customize the training to Latino worker needs. However, due to the limitations of behavior change strategies, future programs should target employers and their obligation to provide safer workplaces. Copyright © 2012 Wiley Periodicals, Inc.

  4. Enhancement of observability and protection of smart power system

    Science.gov (United States)

    Siddique, Abdul Hasib

    It is important for a modern power grid to be smarter in order to provide reliable and sustainable supply of electricity. Traditional way of receiving data from the wired system is a very old and outdated technology. For a quicker and better response from the electric system, it is important to look at wireless systems as a feasible option. In order to enhance the observability and protection it is important to integrate wireless technology with the modern power system. In this thesis, wireless network based architecture for wide area monitoring and an alternate method for performing current measurement for protection of generators and motors, has been adopted. There are basically two part of this project. First part deals with the wide area monitoring of the power system and the second part focuses more on application of wireless technology from the protection point of view. A number of wireless method have been adopted in both the part, these includes Zigbee, analog transmission (Both AM and FM) and digital transmission. The main aim of our project was to propose a cost effective wide area monitoring and protection method which will enhance the observability and stability of power grid. A new concept of wireless integration in the power protection system has been implemented in this thesis work.

  5. Falls and Fall Prevention in Older Adults With Early-Stage Dementia: An Integrative Review.

    Science.gov (United States)

    Lach, Helen W; Harrison, Barbara E; Phongphanngam, Sutthida

    2017-05-01

    Older adults with mild cognitive impairment (MCI) and early-stage dementia have an increased risk of falling, with risks to their health and quality of life. The purpose of the current integrative review was to evaluate evidence on fall risk and fall prevention in this population. Studies were included if they examined falls or fall risk factors in older adults with MCI or early-stage dementia, or reported interventions in this population; 40 studies met criteria. Evidence supports the increased risk of falls in individuals even in the early stages of dementia or MCI, and changes in gait, balance, and fear of falling that may be related to this increased fall risk. Interventions included exercise and multifactorial interventions that demonstrated some potential to reduce falls in this population. Few studies had strong designs to provide evidence for recommendations. Further study in this area is warranted. [Res Gerontol Nurs. 2017; 10(03):139-148.]. Copyright 2016, SLACK Incorporated.

  6. Beam loss monitor system for machine protection

    CERN Document Server

    Dehning, B

    2005-01-01

    Most beam loss monitoring systems are based on the detection of secondary shower particles which depose their energy in the accelerator equipment and finally also in the monitoring detector. To allow an efficient protection of the equipment, the likely loss locations have to be identified by tracking simulations or by using low intensity beams. If superconducting magnets are used for the beam guiding system, not only a damage protection is required but also quench preventions. The quench levels for high field magnets are several orders of magnitude below the damage levels. To keep the operational efficiency high under such circumstances, the calibration factor between the energy deposition in the coils and the energy deposition in the detectors has to be accurately known. To allow a reliable damage protection and quench prevention, the mean time between failures should be high. If in such failsafe system the number of monitors is numerous, the false dump probability has to be kept low to keep a high operation...

  7. Assessment of physical protection systems: EVA method

    International Nuclear Information System (INIS)

    Bernard, J.-L.; Lamotte, C.; Jorda, A.

    2001-01-01

    CEA's missions in various sectors of activity such as nuclear, defence, industrial contracts and the associated regulatory requirements, make it necessary to develop a strategy in the field of physical protection. In particular, firms having nuclear materials are subject to the July 25, 1980 law no.80-572 on the protection and control of nuclear materials. A holding permit delivered by the regulatory authority is conditioned to the protection by the operator of the nuclear materials used. In France it is the nuclear operator who must demonstrate, in the form of a security study, that potential aggressors would be neutralised before they could escape with the material. To meet these requirements, we have developed methods to assess the vulnerability of our facilities. The EVA method, the French acronym for 'Evaluation de la vulnerabilite des Acces' (access vulnerability system) allows dealing with internal and external threats involving brutal actions. In scenarios relating to external threat, the intruders get past the various barriers of our protection system, attempting to steal a large volume of material in one swoop and then escape. In the case of internal threat, the goal is the same. However, as the intruder usually has access to the material in the scope of his activities, the action begins at the level of the target. Our protection system is based on in-depth defense where the intruders are detected and then delayed in their advance towards their target to allow time for intervention forces to intercept them

  8. Falls incidence underestimates the risk of fall-related injuries in older age groups : a comparison with the FARE (Falls risk by Exposure)

    NARCIS (Netherlands)

    Etman, Astrid; Wijlhuizen, Gert Jan; van Heuvelen, Marieke J. G.; Chorus, Astrid; Hopman-Rock, Marijke

    Background: up till now, the risk of falls has been expressed as falls incidence (i.e. the number of falls or fallers per 100 person-years). However, the risk of an accident or injury is the probability of having an accident or injury per unit of exposure. The FARE ( Falls risk by Exposure) is a

  9. Falls incidence underestimates the risk of fall-related injuries in older age groups: a comparison with the FARE (Falls risk by Exposure)

    NARCIS (Netherlands)

    Etman, A.; Wijlhuizen, G.J.; van Heuvelen, M.J.G.; Chorus, A.M.J.; Hopman-Rock, M.

    2012-01-01

    Background: up till now, the risk of falls has been expressed as falls incidence (i.e. the number of falls or fallers per 100 person-years). However, the risk of an accident or injury is the probability of having an accident or injury per unit of exposure. The FARE (Falls risk by Exposure) is a

  10. Falls incidence underestimates the risk of fall-related injuries in older age groups: A comparison with the FARE (Falls risk by exposure)

    NARCIS (Netherlands)

    Etman, A.; Wijlhuizen, G.J.; Heuvelen, M.J.G. van; Chorus, A.; Hopman-Rock, M.

    2012-01-01

    Background: up till now, the risk of falls has been expressed as falls incidence (i.e. the number of falls or fallers per 100 person-years). However, the risk of an accident or injury is the probability of having an accident or injury per unit of exposure. The FARE (Falls risk by Exposure) is a

  11. A Study of Rate and Predictors of Fall Among Elderly Patients in a University Hospital.

    Science.gov (United States)

    al Tehewy, Mahi Mahmoud; Amin, Ghada Essam; Nassar, Nahla Wassem

    2015-12-01

    hematomas, and 4% had fractures and lacerations. Elderly patients with anemia, osteoporosis, and history of a fall are more prone to falls and should be considered in fall protective measures.

  12. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  13. Falls, a fear of falling and related factors in older adults with complex chronic disease.

    Science.gov (United States)

    Lee, JuHee; Choi, MoonKi; Kim, Chang Oh

    2017-12-01

    To identify factors influencing falls and the fear of falling among older adults with chronic diseases in Korea. The fear of falling and falls in older adults are significant health problems towards which healthcare providers should direct their attention. Further investigation is needed to improve nursing practice specifically decreasing risk of falls and the fear of falling in Korea. Descriptive, cross-sectional survey. A convenience sample of 108 patients was recruited at the geriatric outpatient department of a tertiary hospital in Seoul, Korea. Demographic characteristics, comorbidities, medication use, fall history, level of physical activity, activities of daily living, mobility, muscle strength, and a fear of falling were investigated. Student's t tests, chi-square tests and multiple linear regressions were used in statistical analysis. Thirty-six participants (33.3%) among 108 subjects reported experiencing ≥1 falls in the past year. Marital status and the use of antipsychotics were associated with falls, while other factors were not significantly related to falls. Only benign prostatic hypertrophy and polypharmacy were significantly related to the fear of falling in the analysis of the relationships between chronic disease, medication use and fear of falling. In the regression model, the number of comorbidities, level of physical activity, activities of daily living and mobility were predictors of a fear of falling. Medication use was marginally significant, in the model. Increasing physical activity, functional fitness and physical independence is important to decrease the fear of falling, and to encourage active and healthy lives in older adults. The findings from this study provide evidence for the development of nursing interventions for older adults. We recommend early screening for a fear of falling and nursing interventions to decrease the fear of falling through enhancing physical activity level and function. © 2017 John Wiley & Sons Ltd.

  14. Heat Exchange in “Human body - Thermal protection - Environment” System

    Science.gov (United States)

    Khromova, I. V.

    2017-11-01

    This article is devoted to the issues of simulation and calculation of thermal processes in the system called “Human body - Thermal protection - Environment” under low temperature conditions. It considers internal heat sources and convective heat transfer between calculated elements. Overall this is important for the Heat Transfer Theory. The article introduces complex heat transfer calculation method and local thermophysical parameters calculation method in the system called «Human body - Thermal protection - Environment», considering passive and active thermal protections, thermophysical and geometric properties of calculated elements in a wide range of environmental parameters (water, air). It also includes research on the influence that thermal resistance of modern materials, used in special protective clothes development, has on heat transfer in the system “Human body - Thermal protection - Environment”. Analysis of the obtained results allows adding of the computer research data to experiments and optimizing of individual life-support system elements, which are intended to protect human body from exposure to external factors.

  15. Association between obesity, risk of falls and fear of falling in older women

    Directory of Open Access Journals (Sweden)

    Silvia Gonçalves Ricci Neri

    2017-11-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n4p450   The aim of this cross-sectional study was to investigate the association between obesity, risk of falls and fear of falling in older women. Two hundred and twenty-six volunteers (68.05 ± 6.22 years, 68.06 ± 11.79 kg, 1.56 ± 0.06 m were classified as normal weight, overweight or obese, according to the body mass index. Risk of falls and fear of falling were evaluated using QuickScreen Clinical Falls Risk Assessment and Falls Efficiency Scale – International (FES-I, respectively. Comparisons between groups were conducted using Chi-square and ANOVA One-way tests. The significance level was set at p< 0.05. Obesity was associated with greater probability of falls (p< 0.001, which may be partly explained by decreased muscle strength (p< 0.001 and reaction time (p< 0.001. In addition, significant differences between groups was observed in FES-I score (p< 0.01, with obese women showing more pronounced fear of falling (30.10 ± 8.4 than normal weigh (25. 33 ± 7.11, p< 0.01 and overweight subjects (26.97 ± 7.05, p< 0.05. These findings corroborate previous evidence pointing obesity as a major risk factor for falls. Therefore, health professionals dealing with fall prevention should consider the effects of overweight.

  16. Pontomedullary lacerations in falls from a height--a retrospective autopsy study.

    Science.gov (United States)

    Zivković, Vladimir; Nikolić, Slobodan; Babić, Dragan; Djonić, Danijela; Atanasijević, Tatjana; Djurić, Marija

    2012-05-01

    Brainstem pontomedullary laceration (PML) in falls from a height appears as isolated cases and usually in feet-first impacts with a ring fracture. The aim of this study was to determine the frequency of PML in falls from a height, as well as the frequency of concomitant head and neck injuries. Out of 261 cases, PML was present in 40. An impact to the chin, as well as a feet- or buttocks-first impact, most often led to PML owing to transmission of the impact force. Also, a lateral, frontal, or posterior head impact, with subsequent hinge fracture, as well as the frontoposterior hyperextension of the head associated with an upper spine fracture, could be possible mechanisms of PML in falls from a height. The jawbone and other facial bones act as shock absorbers, and their fracture diminishes energy transfer toward the skull and protects the brain and brainstem from injury. © 2011 American Academy of Forensic Sciences.

  17. Reactor protection systems for the Replacement Research Reactor, ANSTO

    International Nuclear Information System (INIS)

    Morris, C.R.

    2003-01-01

    The 20-MW Replacement Research Reactor Project which is currently under construction at ANSTO will have a combination of a state of the art triplicated computer based reactor protection system, and a fully independent, and diverse, triplicated analogue reactor protection system, that has been in use in the nuclear industry, for many decades. The First Reactor Protection System (FRPS) consists of a Triconex triplicated modular redundant system that has recently been approved by the USNRC for use in the USA?s power reactor program. The Second Reactor Protection System is a hardwired analogue system supplied by Foxboro, the Spec 200 system, which is also Class1E qualified. The FRPS is used to drop the control rods when its safety parameter setpoints have been reached. The SRPS is used to drain the reflector tank and since this operation would result in a reactor poison out due to the time it would take to refill the tank the FRPS trip setpoints are more limiting. The FRPS and SRPS have limited hardwired indications on the control panels in the main control room (MCR) and emergency control centre (ECC), however all FRPS and SRPS parameters are capable of being displayed on the reactor control and monitoring system (RCMS) video display units. The RCMS is a Foxboro Series I/A control system which is used for plant control and monitoring and as a protection system for the cold neutron source. This paper will provide technical information on both systems, their trip logics, their interconnections with each other, and their integration into the reactor control and monitoring system and control panels. (author)

  18. NOVA Fall 2000 Teacher's Guide.

    Science.gov (United States)

    Ransick, Kristina; Rosene, Dale; Sammons, Fran Lyons; Sammons, James

    This teacher's guide complements six programs that aired on the Public Broadcasting System (PBS) in the fall of 2000. Programs include: (1) "Lincoln's Secret Weapon"; (2) "Hitler's Lost Sub"; (3) "Runaway Universe"; (4) "Garden of Eden"; (5) "Dying to Be Thin"; and (6) "Japan's Secret…

  19. Design of the interlock and protection system for the SPIDER experiment

    International Nuclear Information System (INIS)

    Pomaro, N.; Grando, L.; Luchetta, A.; Paolucci, F.; Sartori, F.

    2013-01-01

    Highlights: •A custom designed interlock and protection system for SPIDER experiment is described. •It includes two subsystems implementing slow and fast protection functions. •High reliability PLCs are adopted for slow protection. •Fiber-optic based, custom designed fast logic circuitry is proposed for fast protection. •Accelerators breakdown events are also managed by the fast subsystem. -- Abstract: Unprecedented levels of beam energy and power are required for ITER Neutral Beam Heating systems. SPIDER experiment is an experimental device aimed to test and optimize a full size beam source satisfying ITER requirements. SPIDER experiment operation involves high power, voltage, temperature, and gas pressure. All these critical conditions are present simultaneously, so that any failure if not properly detected and managed is likely to cause severe damage. The Interlock and Protection System is a high-reliability system devoted to the investment protection of SPIDER. Its main purpose is to manage abnormal events occurring in one or more plants in order to minimize adverse consequences. The Interlock System also manages the SPIDER Operating Modes, defining the set and status of the Plants used in the various possible experimental configurations. In addition, the Interlock and Protection System takes care of particular events occurring during normal SPIDER operation, i.e. electrical arcs between accelerator grids, named breakdowns. Their treatment is committed to the Interlock and Protection System, as they need to be managed timely and with absolute reliability like actual faults. To perform the required functions, the Interlock and Protection System is interfaced with most SPIDER plants and with the SPIDER Control and Data Acquisition System. The paper describes the rationale of the protection functions, their implementation in the design and the technical specifications of the system

  20. Sub-assembly accident protection instrumentation systems

    International Nuclear Information System (INIS)

    Vaughan, G.J.; Lunt, A.R.W.; Evans, N.J.; Lawrence, L.A.J.

    1982-01-01

    The possibility of an incident in a sub-assembly progressing to the stage at which the whole core may be at hazard has to be guarded against. It is proposed that for CDFR specific instrumentation will be provided to protect against this incident. Three such systems are described, these are: Acoustic Boiling Noise Detection, Burst Pin Detection and Individual Sub-Assembly Thermocouple (ISAT) monitoring. In the ISAT case, multiplexers and microprocessors are employed, using novel techniques to ensure failure-to-safety. The role of these systems and the implementation of them in the reactor design are also considered. It is concluded that sufficient protection can be provided for both core and breeder sub-assemblies

  1. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  2. Characterization of the protective capacity of flooring systems using force-deflection profiling.

    Science.gov (United States)

    Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C

    2013-01-01

    'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Safety Analysis for Power Reactor Protection System

    International Nuclear Information System (INIS)

    Eisawy, E.A.; Sallam, H.

    2012-01-01

    The main function of a Reactor Protection System (RPS) is to safely shutdown the reactor and prevents the release of radioactive materials. The purpose of this paper is to present a technique and its application for used in the analysis of safety system of the Nuclear Power Plant (NPP). A more advanced technique has been presented to accurately study such problems as the plant availability assessments and Technical Specifications evaluations that are becoming increasingly important. The paper provides the Markov model for the Reactor Protection System of the NPP and presents results of model evaluations for two testing policies in technical specifications. The quantification of the Markov model provides the probability values that the system will occupy each of the possible states as a function of time.

  4. Fall prevention intervention technologies: A conceptual framework and survey of the state of the art.

    Science.gov (United States)

    Hamm, Julian; Money, Arthur G; Atwal, Anita; Paraskevopoulos, Ioannis

    2016-02-01

    In recent years, an ever increasing range of technology-based applications have been developed with the goal of assisting in the delivery of more effective and efficient fall prevention interventions. Whilst there have been a number of studies that have surveyed technologies for a particular sub-domain of fall prevention, there is no existing research which surveys the full spectrum of falls prevention interventions and characterises the range of technologies that have augmented this landscape. This study presents a conceptual framework and survey of the state of the art of technology-based fall prevention systems which is derived from a systematic template analysis of studies presented in contemporary research literature. The framework proposes four broad categories of fall prevention intervention system: Pre-fall prevention; Post-fall prevention; Fall injury prevention; Cross-fall prevention. Other categories include, Application type, Technology deployment platform, Information sources, Deployment environment, User interface type, and Collaborative function. After presenting the conceptual framework, a detailed survey of the state of the art is presented as a function of the proposed framework. A number of research challenges emerge as a result of surveying the research literature, which include a need for: new systems that focus on overcoming extrinsic falls risk factors; systems that support the environmental risk assessment process; systems that enable patients and practitioners to develop more collaborative relationships and engage in shared decision making during falls risk assessment and prevention activities. In response to these challenges, recommendations and future research directions are proposed to overcome each respective challenge. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  5. 78 FR 40382 - Modification of Class D and E Airspace; Twin Falls, ID

    Science.gov (United States)

    2013-07-05

    ... using the Navigation (RNAV) Global Positioning System (GPS) and the Instrument Landing System (ILS) or... or more above the surface of the earth. * * * * * ANM ID E5 Twin Falls, ID [Modified] Twin Falls...

  6. Problems in creating enviroment and health protection systems

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Reznichenko, V.Yu.

    1981-01-01

    The problems in creating environmental and health protection systems are considered with relation to development of nuclear energetics facilities. A problem of transition from the system of detection and observation to the uniform system of environment and health protection and control is set. The objectives and problems of such a system are analyzed and the basic principles of their construction are outlined. A system conception for a fuel energetic complex is described. Usefulness of such systems in solving problems of sites of industrial objects including nuclear power industrial objects, of removal of these objects from service and etc. is shown. New requirements to medical-biological investigations on designing of such a system are discussed [ru

  7. Protective systems and its protective switching elements on local failures of large slow-capacitor bank system

    International Nuclear Information System (INIS)

    Hasegawa, Mitsuo; Inoue, Kunikazu; Ueno, Isao.

    1994-01-01

    In various applications of pulsed power technologies, large capacitor bank systems are used to feed high current impulse to different experimental devices. The accidental electric breakdown in one of the capacitors in a parallel connection of the large bank may result in serious damages such as mechanical explosion and oil effusion or fire. In most fast banks, each unit capacitor has an output gap switch, which is expected to decouple the capacitors one another. However, no such special element is adopted usually in the slow bank system, partly because of the economical consideration. We have developed a novel and inexpensive protective element for these relatively slow capacitor banks, utilizing a concept of the enclosed type of the fast breakers. The principle of the operation of the protection elements is verified by a simulation experiment. Their practical effectiveness is also successfully demonstrated in the application to the system of the pulsed high magnetic field generator. (author)

  8. Reported Systems Changes and Sustainability Perceptions of Three State Departments of Health Implementing Multi-Faceted Evidence-Based Fall Prevention Efforts

    Directory of Open Access Journals (Sweden)

    Matthew Lee Smith

    2017-06-01

    Full Text Available Although the concepts of systems change and sustainability are not new, little is known about the factors associated with systems change sustaining multi-state, multi-level fall prevention efforts. This exploratory study focuses on three State Departments of Health (DOH that were awarded 5-year funding from the Centers for Disease Control and Prevention to simultaneously implement four separate yet related evidence-based fall prevention initiatives at the clinical, community, and policy level. The purpose of this study was to examine changes in partnerships and collaborative activities that occurred to accomplish project goals (examining changes in the context of “before funding” and “after funding was received”. Additionally, this study explored changes in State DOH perceptions about action related to sustainability indicators in the context of “during funding” and “after funding ends.” Findings from this study document the partnership and activity changes necessary to achieve defined fall prevention goals after funding is received, and that the importance of sustainability indicator documentation is seen as relevant during funding, but less so after the funding ends. Findings from this study have practice and research implications that can inform future funded efforts in terms of sector and stakeholder engagement necessary for initiating, implementing, and sustaining community- and clinical-based fall prevention interventions.

  9. New horizons in fall prevention.

    Science.gov (United States)

    Lord, Stephen R; Close, Jacqueline C T

    2018-04-25

    Falls pose a major threat to the well-being and quality of life of older people. Falls can result in fractures and other injuries, disability and fear and can trigger a decline in physical function and loss of autonomy. This article synthesises recent published findings on fall risk and mobility assessments and fall prevention interventions and considers how this field of research may evolve in the future. Fall risk topics include the utility of remote monitoring using wearable sensors and recent work investigating brain activation and gait adaptability. New approaches for exercise for fall prevention including dual-task training, cognitive-motor training with exergames and reactive step training are discussed. Additional fall prevention strategies considered include the prevention of falls in older people with dementia and Parkinson's disease, drugs for fall prevention and safe flooring for preventing fall-related injuries. The review discusses how these new initiatives and technologies have potential for effective fall prevention and improved quality of life. It concludes by emphasising the need for a continued focus on translation of evidence into practice including robust effectiveness evaluations of so that resources can be appropriately targeted into the future.

  10. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve ''control loops'' between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  11. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely-activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve (control loops) between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  12. Railway automatic safety protection system based on GPS

    Directory of Open Access Journals (Sweden)

    Fu Hai Juan

    2016-01-01

    Full Text Available The automatic protection system of railway safety is designed for the railway construction workers to protect alarm, and the safety protection device by using GPS satellite positioning system to acquire location information of the operating point, through the CTC/TDCS system and computer monitoring system for the running of the train position and the arithmetic distance. Achieving timely and continuously forecasts about the distance of the train which is apart from the operating point to prompt the voice alarm of the approaching train. Using digital technology to realize the function of the traditional analog interphone, eliminates the quality problems of the call. With the GSM-R, mobile wireless transmission channel and terminal technology, it overcomes the restrictions of the analog interphone which influenced by communication distance and more problems of blind areas. Finally to achieve practical, convenient, applicable and adaptable design goals.

  13. The prevention of falls in later life. A report of the Kellogg International Work Group on the Prevention of Falls by the Elderly.

    Science.gov (United States)

    1987-04-01

    Although falls among the elderly carry high costs to individuals and society, the prevention of falls in later life has not received adequate attention from health care professionals. The prevalence of falls appears to involve roughly one-third of persons aged 65 and over, and the risk of falling and suffering serious injury increases substantially up to the eighth decade of life. The proportion of falls which result in fracture is low, but the absolute number of older people who suffer fractures is high and places heavy demands on health care systems. Even falls which result in no physical injury often have serious social and psychological consequences for the elderly, including loss of confidence and restrictions in mobility, and high proportions of older people report fears of falling. There is a need to provide accurate information about the causes and prevention of falls in later life. Falls are not part of the normal aging process. Rather, they are due to underlying physical illnesses, medications, and environmental hazards, often in interaction. This report provides an overview of the elderly population at risk of falling and suffering serious injury, some of the reasons older people fall, and the methods to prevent falls which have been developed in both community and institutional settings. In addition, it suggests some of the practical steps which can be taken by health and social care professionals and by older people and their families in order to prevent falls. Empirical knowledge about the causes of falls by the elderly and the most effective methods of prevention remains limited. Major barriers to research have been the lack of a clear definition of a fall and the fact that falls are not included in medical diagnostic indices. It is recommended that falls be recorded as a disease entity in Index Medicus and in the International Classification of Diseases Xth Revision. To facilitate future comparisons of research findings on falls, a definition of a

  14. Disability is an Independent Predictor of Falls and Recurrent Falls in People with Parkinson's Disease Without a History of Falls: A One-Year Prospective Study.

    Science.gov (United States)

    Almeida, Lorena R S; Sherrington, Catherine; Allen, Natalie E; Paul, Serene S; Valenca, Guilherme T; Oliveira-Filho, Jamary; Canning, Colleen G

    2015-01-01

    Predictors of falls in people with Parkinson's disease (PD) who have not previously fallen are yet to be identified. We aimed to identify predictors of all falls and recurrent falls in people with PD who had not fallen in the previous year and to explore the timing of falls in a 12-month follow-up period. Participants with PD (n = 130) were assessed by disease-specific, self-report and balance measures. Falls were recorded prospectively for 12 months. Univariate and multivariate analyses were performed. Kaplan-Meier survival analysis was used to investigate time to falling. Forty participants (31%) had ≥1 fall during follow-up and 21 (16%) had ≥2 falls. Disability, reduced balance confidence and greater concern about falling were associated with ≥1 fall in univariate analyses. Additionally, PD duration and severity, freezing of gait and impaired balance were associated with ≥2 falls (p Disability (Schwab and England scale, Odds Ratio [OR] = 0.56 per 10 points increase; 95% confidence interval [CI] 0.39-0.80; p = 0.002) was associated with ≥1 fall in the final multivariate model (area under the receiver operating characteristic curve [AUC] = 0.65; 95% CI 0.55-0.76; p = 0.005). Disability (Unified Parkinson's Disease Rating Scale activities of daily living, OR = 1.20; 95% CI 1.07-1.34; p = 0.001) and levodopa equivalent dose (OR = 1.11 per 100 mg increase; 95% CI 0.95-1.30; p = 0.19) were associated with ≥2 falls in the final multivariate model (AUC = 0.72; 95% CI 0.60-0.84; p = 0.001). Recurrent fallers experienced their first fall earlier than single fallers (p disability was the strongest single predictor of all falls and recurrent falls.

  15. The history of falls and the association of the timed up and go test to falls and near-falls in older adults with hip osteoarthritis

    Directory of Open Access Journals (Sweden)

    Faulkner Robert A

    2007-07-01

    Full Text Available Abstract Background Falling accounts for a significant number of hospital and long-term care admissions in older adults. Many adults with the combination of advancing age and functional decline associated with lower extremity osteoarthritis (OA, are at an even greater risk. The purpose of this study was to describe fall and near-fall history, location, circumstances and injuries from falls in a community-dwelling population of adults over aged 65 with hip OA and to determine the ability of the timed up and go test (TUG to classify fallers and near-fallers. Method A retrospective observational study of 106 older men and women with hip pain for six months or longer, meeting a clinical criteria for the presence of hip OA at one or both hips. An interview for fall and near-fall history and administration of the TUG were administered on one occasion. Results Forty-five percent of the sample had at least one fall in the past year, seventy-seven percent reported occasional or frequent near-falls. The majority of falls occurred during ambulation and ascending or descending steps. Forty percent experienced an injury from the fall. The TUG was not associated with history of falls, but was associated with near-falls. Higher TUG scores occurred for those who were older, less mobile, and with greater number of co-morbidities. Conclusion A high percentage of older adults with hip OA experience falls and near-falls which may be attributed to gait impairments related to hip OA. The TUG could be a useful screening instrument to predict those who have frequent near-falls, and thus might be useful in predicting risk of future falls in this population.

  16. Diagnosis and Tests: Evaluating a Fall or Risk of Falling

    Science.gov (United States)

    ... as a physical therapist, who can evaluate your fall risk. If your healthcare provider concludes that you are ... to check for things that can impact your fall risk, such as electrolyte balance and the possibility of ...

  17. Modulation of LISA free-fall orbits due to the Earth-Moon system

    Energy Technology Data Exchange (ETDEWEB)

    Cerdonio, Massimo; Marzari, Francesco [Department of Physics, University of Padova and INFN Padova, via Marzolo 8, I-35131 Padova (Italy); De Marchi, Fabrizio [Department of Physics, University of Trento and INFN Trento, I-38100 Povo (Trento) (Italy); De Pietri, Roberto [Department of Physics, University of Parma and INFN Parma I-43100 Parma (Italy); Jetzer, Philippe [Institute of Theoretical Physics, University of Zuerich, Winterhurerstrasse 190, 8057 Zuerich (Switzerland); Mazzolo, Giulio [Max Planck Institut fuer Gravitationsphysik, Callinstrasse 38, 30167 Hannover (Germany); Ortolan, Antonello [INFN Laboratori Nazionali di Legnaro, Viale dell' Universita 35020 Legnaro (Padova) (Italy); Sereno, Mauro, E-mail: fdemarchi@science.unitn.i [Dipartimento di Fisica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy)

    2010-08-21

    We calculate the effect of the Earth-Moon (EM) system on the free-fall motion of LISA test masses. We show that the periodic gravitational pulling of the EM system induces a resonance with fundamental frequency 1 yr{sup -1} and a series of periodic perturbations with frequencies equal to integer harmonics of the synodic month ({approx_equal} 3.92 x 10{sup -7} Hz). We then evaluate the effects of these perturbations (up to the 6th harmonics) on the relative motions between each test mass couple, finding that they range between 3 mm and 10 pm for the 2nd and 6th harmonic, respectively. If we take the LISA sensitivity curve, as extrapolated down to 10{sup -6} Hz in Bender (2003 Class. Quantum Grav. 20 301-10), we obtain that a few harmonics of the EM system can be detected in the Doppler data collected by the LISA space mission. This suggests that the EM system gravitational near field could provide an additional crosscheck to the calibration of LISA, as extended to such low frequencies.

  18. Modulation of LISA free-fall orbits due to the Earth-Moon system

    International Nuclear Information System (INIS)

    Cerdonio, Massimo; Marzari, Francesco; De Marchi, Fabrizio; De Pietri, Roberto; Jetzer, Philippe; Mazzolo, Giulio; Ortolan, Antonello; Sereno, Mauro

    2010-01-01

    We calculate the effect of the Earth-Moon (EM) system on the free-fall motion of LISA test masses. We show that the periodic gravitational pulling of the EM system induces a resonance with fundamental frequency 1 yr -1 and a series of periodic perturbations with frequencies equal to integer harmonics of the synodic month (≅ 3.92 x 10 -7 Hz). We then evaluate the effects of these perturbations (up to the 6th harmonics) on the relative motions between each test mass couple, finding that they range between 3 mm and 10 pm for the 2nd and 6th harmonic, respectively. If we take the LISA sensitivity curve, as extrapolated down to 10 -6 Hz in Bender (2003 Class. Quantum Grav. 20 301-10), we obtain that a few harmonics of the EM system can be detected in the Doppler data collected by the LISA space mission. This suggests that the EM system gravitational near field could provide an additional crosscheck to the calibration of LISA, as extended to such low frequencies.

  19. Large thermal protection system panel

    Science.gov (United States)

    Weinberg, David J. (Inventor); Myers, Franklin K. (Inventor); Tran, Tu T. (Inventor)

    2003-01-01

    A protective panel for a reusable launch vehicle provides enhanced moisture protection, simplified maintenance, and increased temperature resistance. The protective panel includes an outer ceramic matrix composite (CMC) panel, and an insulative bag assembly coupled to the outer CMC panel for isolating the launch vehicle from elevated temperatures and moisture. A standoff attachment system attaches the outer CMC panel and the bag assembly to the primary structure of the launch vehicle. The insulative bag assembly includes a foil bag having a first opening shrink fitted to the outer CMC panel such that the first opening and the outer CMC panel form a water tight seal at temperatures below a desired temperature threshold. Fibrous insulation is contained within the foil bag for protecting the launch vehicle from elevated temperatures. The insulative bag assembly further includes a back panel coupled to a second opening of the foil bag such that the fibrous insulation is encapsulated by the back panel, the foil bag, and the outer CMC panel. The use of a CMC material for the outer panel in conjunction with the insulative bag assembly eliminates the need for waterproofing processes, and ultimately allows for more efficient reentry profiles.

  20. Seismic design criteria of fire protection systems for DOE facilities

    International Nuclear Information System (INIS)

    Hardy, G.; Cushing, R.; Driesen, G.

    1991-01-01

    Fire protection systems are critical to the safety of personnel and to the protection of inventory during any kind of emergency situation that involves a fire. The importance of these fire protection systems is hightened for DOE facilities which often house nuclear, chemical or scientific processes. Current research into the topic of open-quotes fires following earthquakesclose quotes has demonstrated that the risks of a fire starting as a result of a major earthquake can be significant. Thus, fire protection systems need to be designed to withstand the anticipated seismic event for the site in question

  1. Risk of falls after withdrawal of fall-risk-increasing drugs: a prospective cohort study

    NARCIS (Netherlands)

    van der Velde, Nathalie; Stricker, Bruno H. Ch; Pols, Huib A. P.; van der Cammen, Tischa J. M.

    2007-01-01

    AIMS: Falling in older persons is a frequent and serious clinical problem. Several drugs have been associated with increased fall risk. The objective of this study was to identify differences in the incidence of falls after withdrawal (discontinuation or dose reduction) of fall-risk-increasing drugs

  2. The design and development of a complex multifactorial falls assessment intervention for falls prevention: The Prevention of Falls Injury Trial (PreFIT).

    Science.gov (United States)

    Bruce, Julie; Ralhan, Shvaita; Sheridan, Ray; Westacott, Katharine; Withers, Emma; Finnegan, Susanne; Davison, John; Martin, Finbarr C; Lamb, Sarah E

    2017-06-01

    This paper describes the design and development of a complex multifactorial falls prevention (MFFP) intervention for implementation and testing within the framework of a large UK-based falls prevention randomised controlled trial (RCT). A complex intervention was developed for inclusion within the Prevention of Falls Injury Trial (PreFIT), a multicentre pragmatic RCT. PreFIT aims to compare the clinical and cost-effectiveness of three alternative primary care falls prevention interventions (advice, exercise and MFFP), on outcomes of fractures and falls. Community-dwelling adults, aged 70 years and older, were recruited from primary care in the National Health Service (NHS), England. Development of the PreFIT MFFP intervention was informed by the existing evidence base and clinical guidelines for the assessment and management of falls in older adults. After piloting and modification, the final MFFP intervention includes seven falls risk factors: a detailed falls history interview with consideration of 'red flags'; assessment of balance and gait; vision; medication screen; cardiac screen; feet and footwear screen and home environment assessment. This complex intervention has been fully manualised with clear, documented assessment and treatment pathways for each risk factor. Each risk factor is assessed in every trial participant referred for MFFP. Referral for assessment is based upon a screening survey to identify those with a history of falling or balance problems. Intervention delivery can be adapted to the local setting. This complex falls prevention intervention is currently being tested within the framework of a large clinical trial. This paper adheres to TIDieR and CONSORT recommendations for the comprehensive and explicit reporting of trial interventions. Results from the PreFIT study will be published in due course. The effectiveness and cost-effectiveness of the PreFIT MFFP intervention, compared to advice and exercise, on the prevention of falls and

  3. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-01-01

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  4. Analysis of fall injuries by body mass index.

    Science.gov (United States)

    Ren, Jun; Waclawczyk, Amanda; Hartfield, Doug; Yu, Shicheng; Kuang, Xiangyu; Zhang, Hongrui; Alamgir, Hasanat

    2014-05-01

    To examine the association of body mass index (BMI) and fall injuries. Data were derived from the 2010 Behavioral Risk Factor Surveillance System and included subjects aged 45 years and older from Texas. The outcome was self-reported falls that resulted in injury to the respondents. Analysis of fall injuries by BMI was conducted and standard errors, 95% confidence intervals (CIs), and coefficients of variation were reported. Complex sample multivariate Poisson regression was used to examine the association of BMI and fall injuries. A total of 18,077 subjects were surveyed in 2010, and 13,235 subjects were aged 45 years old and older. The mean BMI was higher (29.94 vs 28.32 kg/m(2)) among those who reported fall injuries compared with those who did not. The fall injuries reported by obese respondents (relative risk [RR] 1.67) were found to be significantly (P = 0.031) higher compared with normal-weight respondents in the multivariate regression. Other risk factors that had significant association with fall injuries (when adjusted for BMI) were activity limitations (RR 5.00, 95% CI 3.36-7.46) compared with no limitations, and not having formal employment (homemaker: RR 2.68, 95% CI 1.33-5.37; unable to work: RR 5.01, 95% CI 1.87-13.29; out of work and students: RR 3.21, 95% CI 1.41-7.29) compared with the employed population. There is a significant association between obesity and fall injuries in adults aged 45 years old and older in Texas. Interventions in fall prevention, although generally targeted at present to older adults, also should take into account the weight status of the subjects.

  5. Parkinsonian signs are a risk factor for falls.

    Science.gov (United States)

    Dahodwala, Nabila; Nwadiogbu, Chinwe; Fitts, Whitney; Partridge, Helen; Karlawish, Jason

    2017-06-01

    Parkinsonian signs are common, non-specific findings in older adults and associated with increased rates of dementia and mortality. It is important to understand which motor outcomes are associated with parkinsonian signs. To determine the role of parkinsonian signs on fall rates among older adults. We conducted a longitudinal study of primary care patients from the University of Pennsylvania Health System. Adults over 55 years were assessed at baseline through surveys and a neurological examination. We recorded falls over the following 2 years. Parkinsonian signs were defined as the presence of 2 of 4 cardinal signs. Incident falls were compared between subjects with and without parkinsonian signs, and modified Poisson regression used to adjust for potential confounders in the relationship between parkinsonian signs and falls. 982 subjects with a mean age of 68 (s.d. 8.8) years participated. 29% of participants fell and 12% exhibited parkinsonian signs at baseline. The unadjusted RR for falls among individuals with parkinsonian signs was 1.36 (95% CI 1.05-1.76, p=0.02). After adjusting for age, cognitive function, urinary incontinence, depression, diabetes, stroke and arthritis, individuals with parkinsonian signs were still 38% more likely to fall than those without parkinsonian signs (RR 1.38, 95% CI 1.04-1.82; p=0.03). Falls among those with parkinsonian signs were more likely to lead to injury (53% vs 37%; p=0.04). Parkinsonian signs are a significant, independent risk factor for falls. Early detection of this clinical state is important in order to implement fall prevention programs among primary care patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Relationship Between Perceived Risk of Falling and Adoption of Precautions to Reduce Fall Risk.

    Science.gov (United States)

    Blalock, Susan J; Gildner, Paula L; Jones, Jennifer L; Bowling, James M; Casteel, Carri H

    2016-06-01

    To better understand the relationship between perceived risk of falling and awareness and adoption of four specific precautions that older adults have taken to reduce this risk. Cross-sectional. Data were collected in in-person interviews conducted in the homes of study participants. Interviews conducted between March 2011 and September 2013 and lasted an average of 60-90 minutes. A stratified sampling strategy designed to enroll an equal number of homebound and nonhomebound participants was used. All participants (N = 164) were recruited from central North Carolina. Participants were asked about 1-year fall history, perceived risk of falling, restriction of activities because of fear of falling, awareness of four recommended fall prevention behaviors (exercise, annual medication review, bathroom grab bars, safe footwear), and current practice of these behaviors. In bivariate analyses, individuals who were aware of two behaviors recommended to reduce the risk of falling (exercise, use of safe footwear) and had adopted these behaviors perceived their risk of falling as lower than individuals who were aware of the recommended behaviors but had not adopted them. Moreover, in multivariate analyses, individuals who did not know that exercise is recommended to reduce the risk of falling perceived their risk of falling as lower than those who were aware of this recommendation and had adopted it. Individuals were least likely to be aware that medication reviews and exercise are recommended to reduce fall risk. Awareness of behaviors recommended to reduce fall risk appears necessary for adoption of these behaviors to reduce perceived risk. Fall-prevention campaigns should emphasize behaviors where awareness is low. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  7. Falls in Parkinson's disease.

    NARCIS (Netherlands)

    Grimbergen, Y.A.M.; Munneke, M.; Bloem, B.R.

    2004-01-01

    PURPOSE OF REVIEW: To summarize the latest insights into the clinical significance, assessment, pathophysiology and treatment of falls in Parkinson's disease. RECENT FINDINGS: Recent studies have shown that falls are common in Parkinson's disease, even when compared with other fall-prone

  8. Predicting Falls in People with Multiple Sclerosis: Fall History Is as Accurate as More Complex Measures

    Directory of Open Access Journals (Sweden)

    Michelle H. Cameron

    2013-01-01

    Full Text Available Background. Many people with MS fall, but the best method for identifying those at increased fall risk is not known. Objective. To compare how accurately fall history, questionnaires, and physical tests predict future falls and injurious falls in people with MS. Methods. 52 people with MS were asked if they had fallen in the past 2 months and the past year. Subjects were also assessed with the Activities-specific Balance Confidence, Falls Efficacy Scale-International, and Multiple Sclerosis Walking Scale-12 questionnaires, the Expanded Disability Status Scale, Timed 25-Foot Walk, and computerized dynamic posturography and recorded their falls daily for the following 6 months with calendars. The ability of baseline assessments to predict future falls was compared using receiver operator curves and logistic regression. Results. All tests individually provided similar fall prediction (area under the curve (AUC 0.60–0.75. A fall in the past year was the best predictor of falls (AUC 0.75, sensitivity 0.89, specificity 0.56 or injurious falls (AUC 0.69, sensitivity 0.96, specificity 0.41 in the following 6 months. Conclusion. Simply asking people with MS if they have fallen in the past year predicts future falls and injurious falls as well as more complex, expensive, or time-consuming approaches.

  9. Renovation of the cathodic protection system

    NARCIS (Netherlands)

    Schuten, G.; Leggedoor, J.; Polder, R.B.; Peelen, W.H.A.

    2003-01-01

    The first system for Cathodic Protection of concrete in the Netherlands was applied to a one bicycle lane of a bridge suffering corrosion due to de-icing salt penetration in 1986. This CP system was based on the Ferex 100S conducting polymer cable anode in a cementitious overlay. Its functioning was

  10. Impact of Y2K problem on physical protection system

    International Nuclear Information System (INIS)

    Kumar, R.; Swadia, N.S.; Zanwar, P.S.; Mishra, G.P.; Salunke, A.S.; Nigam, R.K.

    1999-01-01

    Year 2000 related system failures/problems in Physical Protection System pose no threat to general safety and functioning of any nuclear facility. But there can be potential security threats having radiation safety and non-proliferation concern and hence should be given due importance. Reviewing and testing Physical Protection System for Y2K compliance are easier than other systems as it does not directly affect operation of the plant. The existing emergency response capability at the nuclear facilities should be utilizes effectively to mitigate any Y2K induced events on Physical Protection System with dedicated manpower and channeled efforts

  11. Anode protection system for shutdown of solid oxide fuel cell system

    Science.gov (United States)

    Li, Bob X; Grieves, Malcolm J; Kelly, Sean M

    2014-12-30

    An Anode Protection Systems for a SOFC system, having a Reductant Supply and safety subsystem, a SOFC anode protection subsystem, and a Post Combustion and slip stream control subsystem. The Reductant Supply and safety subsystem includes means for generating a reducing gas or vapor to prevent re-oxidation of the Ni in the anode layer during the course of shut down of the SOFC stack. The underlying ammonia or hydrogen based material used to generate a reducing gas or vapor to prevent the re-oxidation of the Ni can be in either a solid or liquid stored inside a portable container. The SOFC anode protection subsystem provides an internal pressure of 0.2 to 10 kPa to prevent air from entering into the SOFC system. The Post Combustion and slip stream control subsystem provides a catalyst converter configured to treat any residual reducing gas in the slip stream gas exiting from SOFC stack.

  12. Analog subsystem for the plutonium protection system

    International Nuclear Information System (INIS)

    Arlowe, H.D.

    1978-12-01

    An analog subsystem is described which monitors certain functions in the Plutonium Protection System. Rotary and linear potentiometer output signals are digitized, as are the outputs from thermistors and container ''bulge'' sensors. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Facility Physical Protection Program

  13. Fall-related Information seeking behavior of seniors on the web

    NARCIS (Netherlands)

    Askari, Marjan; Eslami, Saied; Medlock, Stephanie; de Rooij, Sophia E.; Abu-Hanna, Ameen

    2014-01-01

    Falls form a major health problem for older persons, and increasingly strain the healthcare system. The Internet is a potentially useful platform for empowering seniors. The aim of this study was therefore to investigate the information-seeking behavior about falls among elderly Internet users. A

  14. Perturbation training can reduce community-dwelling older adults' annual fall risk: a randomized controlled trial.

    Science.gov (United States)

    Pai, Yi-Chung; Bhatt, Tanvi; Yang, Feng; Wang, Edward

    2014-12-01

    Previous studies indicated that a single session of repeated-slip exposure can reduce over 40% of laboratory-induced falls among older adults. The purpose of this study was to determine to what degree such perturbation training translated to the reduction of older adults' annual falls risk in their everyday living. Two hundred and twelve community-dwelling older adults (≥65 years old) were randomly assigned to either the training group (N = 109), who then were exposed to 24 unannounced repeated slips, or the control group (N = 103), who merely experienced one slip during the same walking in the same protective laboratory environment. We recorded their falls in the preceding year (through self-reported history) and during the next 12 months (through falls diary and monitored with phone calls). With this single session of repeated-slip exposure, training cut older adults' annual risk of falls by 50% (from 34% to 15%, p fall during the same 12-month follow-up period (p falls. A single session of repeated-slip exposure could improve community-dwelling older adults' resilience to postural disturbances and, hence, significantly reduce their annual risk of falls. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Adoption of digital safety protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Z.

    1998-01-01

    The application of micro-processor-based digital controllers has been widely propagated among various industries in recent years. While in the nuclear power plant industry, the application of them has also been expanding gradually starting from non-safety related systems, taking advantage of their reliability and maintainability over the conventional analog devices. Based on the careful study of the feasibility of digital controllers to the safety protection system, the Tokyo Electric Power Company proposed on May 1989 the adoption of digital controllers to the safety protection system in the Application for Permission of Establishment of Kashiwazaki-Kariwa units 6 and 7 (ABWR-1350Mwe each). MITI, Ministry of International Trade and Industry, the Japanese regulatory body for electric power generating facilities, had approved this application after careful review. This paper describes a series of supporting activities leading to the MITI's approval of the digital safety protection system and the MITI's licensing activities. (author)

  16. The interplay between gait, falls and cognition: can cognitive therapy reduce fall risk?

    Science.gov (United States)

    Segev-Jacubovski, Orit; Herman, Talia; Yogev-Seligmann, Galit; Mirelman, Anat; Giladi, Nir; Hausdorff, Jeffrey M

    2011-01-01

    In this article, we briefly summarize the incidence and significant consequences of falls among older adults, the insufficient effectiveness of commonly used multifactorial interventions and the evidence linking falls and cognitive function. Recent pharmacologic and nonpharmacologic studies that evaluated the effects of cognitive therapy on fall risk are reviewed. The results of this article illustrate the potential utility of multiple, diverse forms of cognitive therapy for reducing fall risk. The article also indicates that large-scale, randomized controlled trials are warranted and that additional research is needed to better understand the pathophysiologic mechanisms underlying the interplay between human mobility, fall risk and cognitive function. Nonetheless, we suggest that multimodality interventions that combine motor and cognitive therapy should, eventually, be incorporated into clinical practice to enable older adults and patients to move safer and with a reduced fall risk. PMID:21721921

  17. Comment on Origin of Groundwater Discharge at Fall River Springs

    Energy Technology Data Exchange (ETDEWEB)

    Rose, T

    2006-10-20

    that the large volume cold springs associated with the Cascade Volcanoes commonly contain dissolved CO{sub 2} that originated from the volcanoes. This volcanic CO{sub 2} component is readily identified from carbon-14 measurements of the water. Carbon-14 analyses of the Fall River samples indicate that at least 27% of the dissolved inorganic carbon in the springs was derived from a volcanic CO{sub 2} source. Such a large volcanic CO{sub 2} flux requires that the groundwater supplying flow to the Fall River Springs must originate from a volcano where magma degassing is actively occurring. Given the hydrogeologic configuration of the Fall River aquifer system, it appears that the Medicine Lake Volcano is the only likely source of the volcanic CO{sub 2}. These data independently confirm the Medicine Lake highlands as a significant recharge source for the Fall River Springs. Moreover, these data indicate that groundwater recharge occurring on Medicine Lake Volcano must interact with a CO{sub 2} volatile phase derived from the geothermal system beneath the volcano. The lack of hot springs on Medicine Lake Volcano suggests that the geothermal system underlying the volcano is relatively tightly sealed. Nevertheless, it is probable that the geothermal fluid originates from precipitation falling on the volcanic edifice. This is the same water that supplies an important fraction of the Fall River Spring discharge. The source of the geothermal fluid can be evaluated using stable isotopes. The oxygen isotope signature of the geothermal fluid may have been modified by high temperature oxygen isotope exchange with the surrounding rock, but the hydrogen isotope signature should still be diagnostic of the origin of the fluid. Although the geothermal system appears to be largely decoupled from the shallow groundwater system that supplies the Fall River Springs, it is uncertain what impact the development of the geothermal system as an energy resource would have on groundwater

  18. Mobile Phone Based Falling Detection Sensor and Computer-Aided Algorithm for Elderly People

    Directory of Open Access Journals (Sweden)

    Lee Jong-Ha

    2016-01-01

    Full Text Available Falls are dangerous for the elderly population; therefore many fall detection systems have been developed. However, previous methods are bulky for elderly people or only use a single sensor to isolate falls from daily living activities, which makes a fall difficult to distinguish. In this paper, we present a cost-effective and easy-to-use portable fall-detection sensor and algorithm. Specifically, to detect human falls, we used a three-axis accelerator and a three-axis gyroscope in a mobile phone. We used the Fourier descriptor-based frequency analysis method to classify both normal and falling status. From the experimental results, the proposed method detects falling status with 96.14% accuracy.

  19. Meanings of Falls and Prevention of Falls According to Rehabilitation Nurses: A Qualitative Descriptive Study.

    Science.gov (United States)

    Bok, Amy; Pierce, Linda L; Gies, Cheryl; Steiner, Victoria

    2016-01-01

    Guided by Friedemann's theoretical framework, this survey explored the meaning of a fall of an institutionalized older adult or fall prevention to rehabilitation registered nurses and whether the experience changed the nurse's practice. Qualitative, descriptive survey. A convenience sample of 742 rehabilitation nurses was asked to describe these experiences and the impact on their practice. Themes discovered related to the meaning of a fall include negative feelings (incongruence) and positive feelings (congruence). Themes related to the meaning of preventing a fall include positive feelings (congruence). Practice change themes emerged from both the experience of a fall and fall prevention. Practice change themes were drawn to Friedemann's (1995) process dimensions. Nurses' experiences and meanings of falls uncovered negative and positive feelings about these falls. New findings of this study were the positive feelings expressed by nurses, when there was no injury or when a fall was prevented. © 2015 Association of Rehabilitation Nurses.

  20. 14 CFR 25.1316 - System lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false System lightning protection. 25.1316... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1316 System lightning... systems to perform these functions are not adversely affected when the airplane is exposed to lightning...

  1. NSTX-U Digital Coil Protection System Software Detailed Design

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-06-01

    The National Spherical Torus Experiment (NSTX) currently uses a collection of analog signal processing solutions for coil protection. Part of the NSTX Upgrade (NSTX-U) entails replacing these analog systems with a software solution running on a conventional computing platform. The new Digital Coil Protection System (DCPS) will replace the old systems entirely, while also providing an extensible framework that allows adding new functionality as desired.

  2. Fault Identification Algorithm Based on Zone-Division Wide Area Protection System

    OpenAIRE

    Xiaojun Liu; Youcheng Wang; Hub Hu

    2014-01-01

    As the power grid becomes more magnified and complicated, wide-area protection system in the practical engineering application is more and more restricted by the communication level. Based on the concept of limitedness of wide-area protection system, the grid with complex structure is divided orderly in this paper, and fault identification and protection action are executed in each divided zone to reduce the pressure of the communication system. In protection zone, a new wide-area...

  3. [Risk factors for falls and survival after falling in elderly people in a community].

    Science.gov (United States)

    Kato, Ryuichi; Takagi, Chika; Sakurai, Naoko; Hoshi, Tanji

    2012-05-01

    The purpose of this study was to assess the risk factors associated with falls and to examine the effects of falls on survival of elderly people in a community. A questionnaire survey was conducted in 16,462 urban elderly dwellers aged 65 years or more in City A in September 2001. A follow-up survey was carried out in September 2004. We analyzed the data of 8,285 subjects who answered both questionnaires and had not relocated by August 2007. Baseline assessments of health and functioning were carried out in 2001. Falls experienced during the 1-year period before September 2004 were recorded, and the deaths were recorded until August 2007. Statistical analysis was performed using a logistic regression model and Cox's proportional hazards analysis. A total of 6,420 subjects (3,127 men and 3,293 women) who had provided complete answers about their falls were included in the analyses. Of these, 27.8% of women and 16.4% of men had experienced falls, while 6.2% of women and 2.1% of men had experienced falls that caused fractures. We found that the likelihood of fall, with or without fracture development, was greater in women than in men (P falls tended to increase with age in both women and men. Risk factors associated with falls, in addition to age and gender, were pain (odds ratio [OR], 1.75), lack of instrumental activities of daily living (IADL; OR, 1.45), poor self-rated health status (OR, 1.42), and presence of disease (OR, 1.35). Risk factors associated with falls that caused fracture were pain (OR, 1.85) and lack of IADL (OR, 1.61). Cox's proportional hazards analysis showed a significant increase in mortality in both men and women who had experienced falls than in those who had not (hazard ratio [HR], 1.94, 1.43). Aging, pain and disease, lack of IADL, and poor self-rated health status were all significant risk factors for falls in elderly people, and a fall was related to subsequent mortality.

  4. Geriatric fall-related injuries.

    Science.gov (United States)

    Hefny, Ashraf F; Abbas, Alaa K; Abu-Zidan, Fikri M

    2016-06-01

    Falls are the leading cause of geriatric injury. We aimed to study the anatomical distribution, severity, and outcome of geriatric fall-related injuries in order to give recommendations regarding their prevention. All injured patients with an age ≥ 60 years who were admitted to Al-Ain Hospital or died in the Emergency Department due to falls were prospectively studied over a four year period. We studied 92 patients. Fifty six of them (60.9%) were females. The mean (standard deviation) of age was 72.2 (9.6) years. Seventy three (89%) of all incidents occurred at home. Eighty three patients (90.2%) fell on the same level. The median (range) ISS was 4 (1-16) and the median GCS (range) was 15 (12-15). The lower limb was the most common injured body region (63%). There were no statistical significant differences between males and females regarding age, ISS, and hospital stay (p = 0.85, p = 0.57, and p = 0.35 respectively). The majority of geriatric fall-related injuries were due to fall from the same level at home. Assessment of risk factors for falls including home hazards is essential for prevention of geriatric fall-related injuries.

  5. Microsoft System Center Data Protection Manager 2012

    CERN Document Server

    Buchannan, Steve; Gomaa, Islam

    2013-01-01

    This book is a Packt tutorial, walking the administrator through the steps needed to create real solutions to the problems and tasks faced when ensuring that their data is protected. This book is for network administrators, system administrators, backup administrators, or IT consultants who are looking to expand their knowledge on how to utilize DPM to protect their organization's data.

  6. 78 FR 66384 - Membership of the Merit Systems Protection Board's Performance Review Board

    Science.gov (United States)

    2013-11-05

    ... MERIT SYSTEMS PROTECTION BOARD Membership of the Merit Systems Protection Board's Performance Review Board AGENCY: Merit Systems Protection Board. ACTION: Notice. SUMMARY: Notice is hereby given of the members of the Merit Systems Protection Board's Performance Review Board. DATES: November 5, 2013...

  7. Multimorbidity predicts falls differentially according to the type of fall in postmenopausal women.

    Science.gov (United States)

    Afrin, Nadia; Honkanen, Risto; Koivumaa-Honkanen, Heli; Lukkala, Pyry; Rikkonen, Toni; Sirola, Joonas; Williams, Lana J; Kröger, Heikki

    2016-09-01

    To ascertain whether the risk of falls of different types is related to morbidity (number of chronic medical conditions) among postmenopausal women. This cohort study uses data from a population-based prospective cohort study (OSTPRE). The study population consisted of 10,594 women aged 47-56 years living in Kuopio Province, Eastern Finland, in 1989, who responded to postal enquiries at both baseline and 5-year follow-up, in 1994. Morbidity (i.e. number of diagnosed chronic medical conditions) was reported in 1989 and falls in 1994. Falls were categorized as slip or nonslip, and 'frequent falls' was defined as two or more in a 12-month period. The risk (odds ratio (OR) with 95% CI) of a fall increased with the number of chronic medical conditions. The OR was 1.28 (1.17-1.40) for those with 1-2 conditions and 1.41 (1.24-1.60) for those with multimorbidity (≥3 conditions) compared with healthy respondents. Multimorbidity was associated with a greater risk of the woman experiencing frequent nonslip falls (OR=2.57; 2.01-3.29) than frequent slip falls (OR=1.46; 1.17-1.80). Adjusting with logistic regression for age, number of medications and smoking did not affect the risk estimates. Multimorbidity has a much smaller effect on slip than on nonslip falls in postmenopausal women. This should be taken into account when investigating the effects of multimorbidity on fall risk in varying weather conditions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Design and implementation based on the classification protection vulnerability scanning system

    International Nuclear Information System (INIS)

    Wang Chao; Lu Zhigang; Liu Baoxu

    2010-01-01

    With the application and spread of the classification protection, Network Security Vulnerability Scanning should consider the efficiency and the function expansion. It proposes a kind of a system vulnerability from classification protection, and elaborates the design and implementation of a vulnerability scanning system based on vulnerability classification plug-in technology and oriented classification protection. According to the experiment, the application of classification protection has good adaptability and salability with the system, and it also approves the efficiency of scanning. (authors)

  9. Magnetic field generated by lightning protection system

    Science.gov (United States)

    Geri, A.; Veca, G. M.

    1988-04-01

    A lightning protection system for today's civil buildings must be electromagnetically compatible with the electronic equipment present in the building. This paper highlights a mathematic model which analyzes the electromagnetic effects in the environment in which the lightning protection system is. This model is developed by means of finite elements of an electrical circuit where each element is represented by a double pole circuit according to the trapezoidal algorithm developed using the finite difference method. It is thus possible to analyze the electromagnetic phenomena associated with the transient effects created by the lightning stroke even for a high-intensity current. Referring to an elementary system comprised of an air terminal, a down conductor, and a ground terminal, numerical results are here laid out.

  10. Falls event detection using triaxial accelerometry and barometric pressure measurement.

    Science.gov (United States)

    Bianchi, Federico; Redmond, Stephen J; Narayanan, Michael R; Cerutti, Sergio; Celler, Branko G; Lovell, Nigel H

    2009-01-01

    A falls detection system, employing a Bluetooth-based wearable device, containing a triaxial accelerometer and a barometric pressure sensor, is described. The aim of this study is to evaluate the use of barometric pressure measurement, as a surrogate measure of altitude, to augment previously reported accelerometry-based falls detection algorithms. The accelerometry and barometric pressure signals obtained from the waist-mounted device are analyzed by a signal processing and classification algorithm to discriminate falls from activities of daily living. This falls detection algorithm has been compared to two existing algorithms which utilize accelerometry signals alone. A set of laboratory-based simulated falls, along with other tasks associated with activities of daily living (16 tests) were performed by 15 healthy volunteers (9 male and 6 female; age: 23.7 +/- 2.9 years; height: 1.74 +/- 0.11 m). The algorithm incorporating pressure information detected falls with the highest sensitivity (97.8%) and the highest specificity (96.7%).

  11. Practical Approach on Lightning and Grounding Protection System

    OpenAIRE

    Shan Jose Varghese

    2015-01-01

    Lightning Protection and Grounding of Electrical and Mechanical equipment’s for the Protection of the Human Beings, Structure of the building and equipment protection, safe working of the Worker at Industry as per my latest practical knowledge in the site environment in extreme climatic condition of low lying areas of the Gulf Region in the challenging projects. All the conductor calculation, Lightning Risk Factor calculations, all the system information regarding the ...

  12. Endogenous hormones, muscle strength, and risk of fall-related fractures in older women.

    Science.gov (United States)

    Sipilä, Sarianna; Heikkinen, Eino; Cheng, Sulin; Suominen, Harri; Saari, Päivi; Kovanen, Vuokko; Alén, Markku; Rantanen, Taina

    2006-01-01

    Among older people, fracture-causing fall often leads to health deterioration. The role of endogenous hormone status and muscle strength on fall-related fracture risk is unclear. This study investigates if, after adjustment for bone density, endogenous hormones and muscle strength would predict fall-related limb fracture incidence in older community-dwelling women followed-up over 10 years. As a part of a prospective population-based study, 187 75-year-old women were investigated. Serum estradiol, testosterone, sex hormone binding globulin, and dehydroepiandrosterone sulfate concentrations were analyzed, and isometric muscle strength and bone mineral density were assessed. Fall-related limb fractures were gathered from patient records. Serum estradiol concentration was a significant predictor of fall-related limb fractures. Women with serum estradiol concentrations less than 0.022 nmol/L had a 3-fold risk (relative risk 3.05; 95% confidence interval, 1.26-7.36), and women with estradiol concentrations between 0.022 and 0.066 nmol/L doubled the risk (relative risk 2.24; 95% confidence interval, 0.97-5.19) of fall-related limb fracture compared to the women with estradiol concentrations ()above 0.066 nmol/L. Adjustment for muscle strength and bone mineral density did not materially change the risk estimates. High muscle strength was associated with a low incidence of fall-related limb fractures. This study showed that in 75-year-old women higher serum estradiol concentration and greater muscle strength were independently associated with a low incidence of fall-related limb fractures even after adjustment for bone density. Our results suggest that hormonal status and muscle strength have their own separate mechanisms protecting from fall-related fractures. This finding is of importance in developing preventive strategies, but calls for further study.

  13. Risk of falling in a stroke unit after acute stroke: The Fall Study of Gothenburg (FallsGOT).

    Science.gov (United States)

    Persson, Carina U; Kjellberg, Sigvar; Lernfelt, Bodil; Westerlind, Ellen; Cruce, Malin; Hansson, Per-Olof

    2018-03-01

    This study aimed to investigate incidence of falls and different baseline variables and their association with falling during hospitalization in a stroke unit among patients with acute stroke. Prospective observational study. A stroke unit at a university hospital. A consecutive sample of stroke patients, out of which 504 were included, while 101 declined participation. The patients were assessed a mean of 1.7 days after admission and 3.8 days after stroke onset. The primary end-point was any fall, from admission to the stroke unit to discharge. Factors associated with falling were analysed using univariable and multivariable Cox hazard regression analyses. Independent variables were related to function, activity and participation, as well as personal and environmental factors. In total, 65 patients (13%) fell at least once. Factors statistically significantly associated with falling in the multivariable analysis were male sex (hazard ratio (HR): 1.88, 95% confidence interval (CI): 1.13-3.14, P = 0.015), use of a walking aid (HR: 2.11, 95% CI: 1.24-3.60, P = 0.006) and postural control as assessed with the modified version of the Postural Assessment Scale for Stroke Patients (SwePASS). No association was found with age, cognition or stroke severity, the HR for low SwePASS scores (⩽24) was 9.33 (95% CI: 2.19-39.78, P = 0.003) and for medium SwePASS scores (25-30) was 6.34 (95% CI: 1.46-27.51, P = 0.014), compared with high SwePASS scores (⩾31). Postural control, male sex and use of a walking aid are associated with falling during hospitalization after acute stroke.

  14. Towards a social and context-aware multi-sensor fall detection and risk assessment platform.

    Science.gov (United States)

    De Backere, F; Ongenae, F; Van den Abeele, F; Nelis, J; Bonte, P; Clement, E; Philpott, M; Hoebeke, J; Verstichel, S; Ackaert, A; De Turck, F

    2015-09-01

    For elderly people fall incidents are life-changing events that lead to degradation or even loss of autonomy. Current fall detection systems are not integrated and often associated with undetected falls and/or false alarms. In this paper, a social- and context-aware multi-sensor platform is presented, which integrates information gathered by a plethora of fall detection systems and sensors at the home of the elderly, by using a cloud-based solution, making use of an ontology. Within the ontology, both static and dynamic information is captured to model the situation of a specific patient and his/her (in)formal caregivers. This integrated contextual information allows to automatically and continuously assess the fall risk of the elderly, to more accurately detect falls and identify false alarms and to automatically notify the appropriate caregiver, e.g., based on location or their current task. The main advantage of the proposed platform is that multiple fall detection systems and sensors can be integrated, as they can be easily plugged in, this can be done based on the specific needs of the patient. The combination of several systems and sensors leads to a more reliable system, with better accuracy. The proof of concept was tested with the use of the visualizer, which enables a better way to analyze the data flow within the back-end and with the use of the portable testbed, which is equipped with several different sensors. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Perceived Fall Risk and Functional Decline: Gender Differences in Patient's Willingness to Discuss Fall Risk, Fall History, or to Have a Home Safety Evaluation.

    Science.gov (United States)

    Greenberg, Marna Rayl; Moore, Elizabeth C; Nguyen, Michael C; Stello, Brian; Goldberg, Arnold; Barraco, Robert D; Porter, Bernadette G; Kurt, Anita; Dusza, Stephen W; Kane, Bryan G

    2016-06-01

    The CDC reports that among older adults, falls are the leading cause of injury-related death and rates of fall-related fractures among older women are twice those of men. We set out to 1) determine patient perceptions (analyzed by gender) about their perceived fall risk compared to their actual risk for functional decline and death and 2) to report their comfort level in discussing their fall history or a home safety plan with their provider. Elders who presented to the Emergency Department (ED†) were surveyed. The survey included demographics, the Falls Efficacy Scale (FES) and the Vulnerable Elders Survey (VES); both validated surveys measuring fall concern and functional decline. Females had higher FES scores (mean 12.3, SD 5.9) than males (mean 9.7, SD 5.9 p = .007) in the 146 surveys analyzed. Females were more likely to report an increased fear of falling, and almost three times more likely to have a VES score of 3 or greater than males (OR = 2.86, 95% CI: 1.17-7.00, p = .02). A strong correlation was observed between FES and VES scores (r = 0.80, p fall risk with a provider; there was no difference between genders (p = .57). In this study, irrespective of gender, there appears to be a high association between subjects' perceived fall risk and risk for functional decline and death. The majority of patients are likely willing to discuss their fall risk with their provider. These findings may suggest a meaningful opportunity for fall risk mitigation in this setting.

  16. Study on pulsed current cathodic protection in a simulated system

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Milin; Li, Helin [Xi' an Jiao Tong Universitiy (China)]|[Tubular Goods Research Center of China National Petroleum Corp. (China); Qiu, Yubing; Guo, Xingpeng [Hua Zhong University of Science and Techonology (China)

    2004-07-01

    The pulsed current cathodic protection (PCCP) is a new cathodic protection (CP) technology and shows more advantages over the conventional DC cathodic protection (DCCP) in oil well casing system. However, little information about PCCP is reported. In this research, a simulated CP system was set up in a pool of 3.5 m x 2.0 m x 3.0 m size, in which the effects of the square wave pulsed current (SWPC) parameters (amplitude: IA, frequency: f, duty cycle: P), auxiliary anode distance (d) and media conductivity ({mu}) on the cathodic potential (E) distribution were studied, and the protection effects of PCCP and DCCP were compared. The results show that with increase of the square wave parameters (IA, f, P), the E distribution becomes more negative and the effects of each current parameter are relate closely to the cathode polarizing state. Only with suitable square wave parameters can the whole cathode be effectively protected. With increase of d and {mu}, the E distribution becomes more uniform. Compared with DCCP system, PCCP system has much more uniform E distribution, costs less average current, and gains much better protection effects. Further, the mechanism of PCCP was analyzed. (authors)

  17. Fear of Falling in Women with Fibromyalgia and Its Relation with Number of Falls and Balance Performance.

    Science.gov (United States)

    Collado-Mateo, D; Gallego-Diaz, J M; Adsuar, J C; Domínguez-Muñoz, F J; Olivares, P R; Gusi, N

    2015-01-01

    To evaluate fear of falling, number of falls, and balance performance in women with FM and to examine the relationship between these variables and others, such as balance performance, quality of life, age, pain, and impact of fibromyalgia. A total of 240 women participated in this cross-sectional study. Of these, 125 had fibromyalgia. Several variables were assessed: age, fear of falling from 0 to 100, number of falls, body composition, balance performance, lower limb strength, health-related quality of life, and impact of fibromyalgia. Women with fibromyalgia reported more falls and more fear of falling. Fear of falling was associated with number of falls in the last year, stiffness, perceived balance problems, impact of FM, and HRQoL whereas the number of falls was related to fear of falling, balance performance with eyes closed, pain, tenderness to touch level, anxiety, self-reported balance problems, impact of FM, and HRQoL. FM has an impact on fear of falling, balance performance, and number of falls. Perceived balance problems seem to be more closely associated with fear of falling than objective balance performance.

  18. Falls in older people

    NARCIS (Netherlands)

    van Dieën, Jaap H.; Pijnappels, Mirjam

    Falls are common incidents, which can have major con-sequences. For example, falls and the interrelated category of accidents being struck by or against objects account for more than 40% of injuries and 30% of injury costs in the USA (Corso et al., 2006). Especially among older adults, falls occur

  19. Distance Protection for Microgrids in Distribution System

    DEFF Research Database (Denmark)

    Lin, Hengwei; Liu, Chengxi; Guerrero, Josep M.

    2015-01-01

    protection decreased. This paper adopts distance protection for one mid-voltage level microgrid in Aalborg, Denmark. Different operation modes of the network are analyzed and tested in the paper. The simulation results show that the variations of the fault currents seen by the forward relays are much larger...... than the backward relays. Meanwhile, the fault currents change little with the randomness of renewable energy except the intermittence. Finally, it shows that the designed distance protection has satisfactory performance to clear the various faults.......Owing to the increasing penetration of distributed generation, there are some challenges for the conventional protection in distribution system. Bidirectional power flow and variable fault current because of the various operation modes may lead to the selectivity and sensitivity of the overcurrent...

  20. Nuclear whistleblower protection system in U.S. and its implication to Japanese regulatory system

    International Nuclear Information System (INIS)

    Tanabe, Tomoyuki; Suzuki, Tatsujiro

    2003-01-01

    The nuclear whistleblower protection system in U.S.A consists of two programs: 1) allegation program and 2) whistleblower protection system. The former is explained by basic act, definition of allegation, anonymous allegation, direct allegation to NRC (Nuclear Regulatory Commission), number of allegation from 1997 to 2001, procedure and period of investigation and notice of allegation to licensees. The latter is explained by basis act, outline of the system, enforcement by NRC and DOL (Department of Labor), number of discrimination compliant and anxiety of licensees. The system is good conditions in U.S.A depend on 1) prevent of illegal act and increase, 2) preparation of procedure and its transparency and 3) enforcement system. However, a hostile act to licensees is found in the whistleblower protection system. There are many problems in Japanese regulatory system. The improvement points of Japanese system are proposed. (S.Y.)

  1. High-voltage short-fall pulse generator

    International Nuclear Information System (INIS)

    Dolbilov, G.V.; Fateev, A.A.; Petrov, V.A.

    1986-01-01

    Powerful high-voltage pulses with short fall times and relatively low afterpulse amplitude are required for the deflection systems of accelerators. A generator is described that provides, into a 75-ohm load, a voltage pulse of up to 100 kV with a fall time of less than 1 nsec and a relative afterpulse amplitude of less than or equal to 15%. The generator employs a short-circuited ferrite-filled line in which shock waves are formed. A magnetic section is used to increase power. The switch is a TGI1-2500/50 thyratron. The main causes of afterpulses and methods for reducing their amplitude are examined

  2. Circuit protection of ehv power systems from 150 to 765 kV

    Energy Technology Data Exchange (ETDEWEB)

    Geise, F; Jaeger, J

    1965-11-01

    Short tripping times required for all faults in ehv transmission systems are obtained by means of differential and comparative protection arrangements. It is essential that protection and communication systems be closely integrated and that special current transformers with linearized cores supply protective devices with correct measured values. By arranging filters between transformer and directional relay, it is possible to use capacitive voltage transformers for high speed protection. A description of power system with backup protection devices is presented.

  3. 'Balancing risk' after fall-induced hip fracture: the older person's need for information.

    Science.gov (United States)

    McMillan, Laura; Booth, Joanne; Currie, Kay; Howe, Tracey

    2014-12-01

    Hip fracture is a significant cause of morbidity and mortality in older people. Healthcare professionals have a role to identify and respond to challenges and concerns that older people face as they strive to manage risk of future falls and rebuild confidence and independence after discharge. This study aimed to explore the postdischarge concerns of older people after fall-induced hip fracture. Glaser's approach to the grounded theory method guided qualitative interviews conducted with 19 older people in their own homes up to 3 months post discharge, in two health authority areas. A theory of 'taking control' was generated. 'Balancing risk' emerged as a key strategy that older people employed to help them to take control after discharge home. Older people attempted to control or 'balance' their risk of future falls and dependence by implementing two further strategies: 'protective guarding' and 'following orders'. The instinctive strategy of protective guarding and the learned strategy of following orders were implemented simultaneously and were characterised by older people aiming to pace their progress and balance risk safely and appropriately. To apply these strategies, older people required information from healthcare professionals. In circumstances where older people did not receive or did not understand the information provided, they were left 'grasping to understand' and were more likely to miscalculate risk. This leads to damaged confidence and in some cases further falls. The concept of balancing risk aims to help healthcare professionals understand the older person's perspective of hip fracture and to recognise the efforts that people make to guard against further injury and dependence in the early postdischarge period. © 2013 Blackwell Publishing Ltd.

  4. Fall-risk prediction in older adults with cancer: an unmet need.

    Science.gov (United States)

    Wildes, Tanya M; Depp, Brittany; Colditz, Graham; Stark, Susan

    2016-09-01

    Falls in older adults with cancer are more common than in noncancer controls, yet no fall-risk screening tool has been validated in this population. We undertook a cross-sectional pilot study of the Falls Risk Questionnaire (FRQ) in 21 adults aged ≥65 receiving systemic cancer therapy. Participants completed the FRQ, geriatric assessment measures, and a measure of fear-of-falling. The recruitment rate was 87.5 %, with 95.2 % completion of the FRQ and additional geriatric assessment and quality of life measures. The FRQ correlated significantly with the Timed Up and Go test (Pearson r 0.479, p = 0.028). In addition, the FRQ score correlated directly with fear-of-falling and inversely with QOL, particularly physical health and neurotoxicity subscales. In conclusion, the FRQ was feasible in older adults receiving cancer therapy and correlates with measures of physical performance, functional status, and fear-of-falling. The FRQ may prove to be a valuable fall-risk screening tool to implement fall-prevention interventions in this vulnerable population of older adults with cancer.

  5. [Fear of falling in a fall clinic for geriatric patients: a pilot study

    NARCIS (Netherlands)

    Dautzenberg, P.LJ.; Buurman, B.H.; Loonen, A.J.; Wouters, C.J.; Olde Rikkert, M.G.M.

    2005-01-01

    OBJECTIVE: In this pilot study we want to determine how often fear of falling occurs in geriatric patients visiting a fall clinic and to study the characteristics of fear of falling and its consequences. DESIGN: Retrospective study of patient's records. METHOD: A random sample of 100 medical records

  6. ICRP Publication 138: Ethical Foundations of the System of Radiological Protection.

    Science.gov (United States)

    Cho, K-W; Cantone, M-C; Kurihara-Saio, C; Le Guen, B; Martinez, N; Oughton, D; Schneider, T; Toohey, R; ZöLzer, F

    2018-02-01

    Despite a longstanding recognition that radiological protection is not only a matter of science, but also ethics, ICRP publications have rarely addressed the ethical foundations of the system of radiological protection explicitly. The purpose of this publication is to describe how the Commission has relied on ethical values, either intentionally or indirectly, in developing the system of radiological protection with the objective of presenting a coherent view of how ethics is part of this system. In so doing, it helps to clarify the inherent value judgements made in achieving the aim of the radiological protection system as underlined by the Commission in Publication 103. Although primarily addressed to the radiological protection community, this publication is also intended to address authorities, operators, workers, medical professionals, patients, the public, and its representatives (e.g. NGOs) acting in the interest of the protection of people and the environment. This publication provides the key steps concerning the scientific, ethical, and practical evolutions of the system of radiological protection since the first ICRP publication in 1928. It then describes the four core ethical values underpinning the present system: beneficence/ non-maleficence, prudence, justice, and dignity. It also discusses how these core ethical values relate to the principles of radiological protection, namely justification, optimisation, and limitation. The publication finally addresses key procedural values that are required for the practical implementation of the system, focusing on accountability, transparency, and inclusiveness. The Commission sees this publication as a founding document to be elaborated further in different situations and circumstances.

  7. Issues in Geriatric Care: Falls.

    Science.gov (United States)

    Patel, Dipesh; Ackermann, Richard J

    2018-05-01

    One in three older adults falls each year. There are approximately 2.5 million falls among older adults treated in emergency departments. Falls account for 87% of all fractures in this age group. The biggest risk factor for falling is a history of falls. Other risk factors include frailty, sedative and anticholinergic drugs, polypharmacy, and a variety of medical conditions. Current recommendations are that all patients age 65 years and older should be asked about falls each year. Patients also can be screened for fall risk with a variety of approaches including questionnaires and the Timed Up & Go test. For patients who have fallen or are at risk, care should focus on correcting reversible home environmental factors that predispose to falls, minimizing the use of drugs with sedating properties, addressing vision conditions, recommending physical exercise (including balance, strength, and gait training), and managing postural hypotension as well as foot conditions and footwear. In addition, vitamin D and calcium supplementation should be considered. For patients needing anticoagulation for medical reasons, an assessment must balance fall risk (and thus bleeding from a fall) versus the risk of discontinuing anticoagulation (eg, sustaining an embolic stroke from atrial fibrillation). Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  8. Slip and fall risk on ice and snow:identification, evaluation and prevention

    OpenAIRE

    Gao, Chuansi

    2004-01-01

    Slip and fall accidents and associated injuries on ice and snow are prevalent among outdoor workers and the general public in winter in many regions of the world. To understand and tackle this multi-factorial problem, a multidisciplinary approach was used to identify and evaluate slip and fall risks, and to propose recommendations for prevention of slips and falls on icy and snowy surfaces. Objectives were to present a systems perspective of slip and fall accidents and related risk factors; t...

  9. Falls self-efficacy and falls incidence in community-dwelling older people: the mediating role of coping.

    Science.gov (United States)

    Loft, Christine C; Jones, Fergal W; Kneebone, Ian I

    2017-11-08

    A cognitive behavioral model predicts that coping responses mediate the relationship between falls related psychological concerns and falls incidence, in community-dwelling older people. If empirical support could be found for this pathway then interventions could be developed to reduce falls risk by targeting coping strategies. Therefore, this study aimed to begin the process of testing whether coping responses mediate the association between falls self-efficacy (a principal element of falls related psychological concerns) and falls incidence, in community-dwelling older people. In a cross-sectional design, 160 community-dwelling older people (31 male, 129 female; mean age 83.47 years) completed the Falls Efficacy Scale-International, the Revised-Ways of Coping Questionnaire, the Turning to Religion subscale of the COPE, and a falls questionnaire. Data were analyzed via mediation analysis using a bootstrapping approach. Lower falls self-efficacy was associated with higher falls incidence, and more self-controlling coping was found to be a partial mediator of this association, with a confidence interval for the indirect effect of (0.003, 0.021) and an effect size of κ 2 = 0.035. The association was not mediated by the other measured coping responses; namely, turning to religion, distancing, seeking social support, accepting responsibility, escape-avoidance, planful problem-solving, and positive reappraisal. Self-controlling coping may mediate the association between falls self-efficacy and falling. If longitudinal studies confirm this finding then coping could be targeted in interventions to reduce falls.

  10. Protective garment ventilation system

    Science.gov (United States)

    Lang, R. (Inventor)

    1970-01-01

    A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

  11. Integration of the environment into the system of radiation protection

    International Nuclear Information System (INIS)

    Higley, K.

    2018-01-01

    In 2005 the International Commission on Radiological Protection (ICRP) embarked on an effort to ensure that the system for environmental radiological protection would be reconcilable with that for radiological protection of man, and with the approaches used for protection of the environment from other potential hazards

  12. Older Adults' Perceptions of and Preferences for a Fall Risk Assessment System: Exploring Stages of Acceptance Model.

    Science.gov (United States)

    Galambos, Colleen; Rantz, Marilyn; Back, Jessie; Jun, Jung Sim; Skubic, Marjorie; Miller, Steven J

    2017-07-01

    Aging in place is a preferred and cost-effective living option for older adults. Research indicates that technology can assist with this goal. Information on consumer preferences will help in technology development to assist older adults to age in place. The study aim was to explore the perceptions and preferences of older adults and their family members about a fall risk assessment system. Using a qualitative approach, this study examined the perceptions, attitudes, and preferences of 13 older adults and five family members about their experience living with the fall risk assessment system during five points in time. Themes emerged in relation to preferences and expectations about the technology and how it fits into daily routines. We were able to capture changes that occurred over time for older adult participants. Results indicated that there was acceptance of the technology as participants adapted to it. Two themes were present across the five points in time-safety and usefulness. Five stages of acceptance emerged from the data from preinstallation to 2 years postinstallation. Identified themes, stages of acceptance, and design and development considerations are discussed.

  13. System Protection Schemes in Eastern Denmark

    DEFF Research Database (Denmark)

    Rasmussen, Joana

    outages in the southern part of the 132-kV system introduce further stress in the power system, eventually leading to a voltage collapse. The local System Protection Scheme against voltage collapse is designed as a response-based scheme, which is dependent on local indication of reactive and active power...... effective measures, because they are associated with large reactive power losses in the transmission system. Ordered reduction of wind generation is considered an effective measure to maintain voltage stability in the system. Reactive power in the system is released due to tripping of a significant amount...... system. In that way, the power system capability could be extended beyond normal limits....

  14. Fear of Falling in Women with Fibromyalgia and Its Relation with Number of Falls and Balance Performance

    Directory of Open Access Journals (Sweden)

    D. Collado-Mateo

    2015-01-01

    Full Text Available Objective. To evaluate fear of falling, number of falls, and balance performance in women with FM and to examine the relationship between these variables and others, such as balance performance, quality of life, age, pain, and impact of fibromyalgia. Methods. A total of 240 women participated in this cross-sectional study. Of these, 125 had fibromyalgia. Several variables were assessed: age, fear of falling from 0 to 100, number of falls, body composition, balance performance, lower limb strength, health-related quality of life, and impact of fibromyalgia. Results. Women with fibromyalgia reported more falls and more fear of falling. Fear of falling was associated with number of falls in the last year, stiffness, perceived balance problems, impact of FM, and HRQoL whereas the number of falls was related to fear of falling, balance performance with eyes closed, pain, tenderness to touch level, anxiety, self-reported balance problems, impact of FM, and HRQoL. Conclusion. FM has an impact on fear of falling, balance performance, and number of falls. Perceived balance problems seem to be more closely associated with fear of falling than objective balance performance.

  15. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  16. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2004-01-01

    The development of new radiological protection recommendations by the International Commission on Radiological Protection (ICRP) continues to be a strategically important undertaking, both nationally and internationally. With the growing recognition of the importance of stakeholder aspects in radiological protection decision making, regional and cultural aspects have also emerged as having potentially significant influence on how protection of the public, workers and the environment are viewed. Differing cultural aspects should therefore be considered by the ICRP in its development of new recommendations. Based on this assumption, the NEA organised the Asian Regional Conference on the Evolution of the System of Radiological Protection to express and explore views from the Far East. Held in Tokyo on 24-25 October 2002, the conference included presentations by the ICRP Chair as well as by radiological protection experts from Japan, the Republic of Korea, China and Australia. The distinct views and needs of these countries were discussed in the context of their regional and cultural heritages. These views, along with a summary of the conference results, are presented in these proceedings. (author)

  17. Fall risk assessment: retrospective analysis of Morse Fall Scale scores in Portuguese hospitalized adult patients.

    Science.gov (United States)

    Sardo, Pedro Miguel Garcez; Simões, Cláudia Sofia Oliveira; Alvarelhão, José Joaquim Marques; Simões, João Filipe Fernandes Lindo; Melo, Elsa Maria de Oliveira Pinheiro de

    2016-08-01

    The Morse Fall Scale is used in several care settings for fall risk assessment and supports the implementation of preventive nursing interventions. Our work aims to analyze the Morse Fall Scale scores of Portuguese hospitalized adult patients in association with their characteristics, diagnoses and length of stay. Retrospective cohort analysis of Morse Fall Scale scores of 8356 patients hospitalized during 2012. Data were associated to age, gender, type of admission, specialty units, length of stay, patient discharge, and ICD-9 diagnosis. Elderly patients, female, with emergency service admission, at medical units and/or with longer length of stays were more frequently included in the risk group for falls. ICD-9 diagnosis may also be an important risk factor. More than a half of hospitalized patients had "medium" to "high" risk of falling during the length of stay, which determines the implementation and maintenance of protocoled preventive nursing interventions throughout hospitalization. There are several fall risk factors not assessed by Morse Fall Scale. There were no statistical differences in Morse Fall Scale score between the first and the last assessment. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Radioactive fall-out in Norway after the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Skjerve, Eystein [Dept. of Food Hygiene, Norwegian College of Veterinary Medicine (Norway)

    1986-07-01

    During the fall-out from the atmosphere during the fifties and sixties, a system of local control of radioactive contamination of food was built up. (LORACON - LOcal RAdioactivity COntrol). The different Meat and Food Inspection Services were equipped with Geiger Mueller instruments. The system was in operation until late seventies. From 1977 there was no testing and calibration of the instruments. The development towards a reduction of the state of readiness was accelerated when the Norwegian Parliament decided that Norway should not establish any nuclear power plants (1979). Only the universities and special institutions as the National Institute of Radiation Hygiene and the Institute for Energy Technique were still able to analyse on radioactive isotopes. The confusion about how much radioactive fall-out from the Chernobyl reactor accident Norway received lasted for some weeks in Norway. Partially, this was due to the lack of instruments, but also many experts rejected the idea that an accident so far away might cause these amounts of fall-out consisted of Iodine and Cesium. The fall-out followed a very irregular pattern both nationally and locally with the mountain areas in Middle Norway most affected.

  19. Radioactive fall-out in Norway after the Chernobyl accident

    International Nuclear Information System (INIS)

    Skjerve, Eystein

    1986-01-01

    During the fall-out from the atmosphere during the fifties and sixties, a system of local control of radioactive contamination of food was built up. (LORACON - LOcal RAdioactivity COntrol). The different Meat and Food Inspection Services were equipped with Geiger Mueller instruments. The system was in operation until late seventies. From 1977 there was no testing and calibration of the instruments. The development towards a reduction of the state of readiness was accelerated when the Norwegian Parliament decided that Norway should not establish any nuclear power plants (1979). Only the universities and special institutions as the National Institute of Radiation Hygiene and the Institute for Energy Technique were still able to analyse on radioactive isotopes. The confusion about how much radioactive fall-out from the Chernobyl reactor accident Norway received lasted for some weeks in Norway. Partially, this was due to the lack of instruments, but also many experts rejected the idea that an accident so far away might cause these amounts of fall-out consisted of Iodine and Cesium. The fall-out followed a very irregular pattern both nationally and locally with the mountain areas in Middle Norway most affected

  20. Temporal Patterns of In-Hospital Falls of Elderly Patients.

    Science.gov (United States)

    López-Soto, Pablo J; Smolensky, Michael H; Sackett-Lundeen, Linda L; De Giorgi, Alfredo; Rodríguez-Borrego, María A; Manfredini, Roberto; Pelati, Cristiano; Fabbian, Fabio

    A potentially important factor yet to receive adequate study is the time when hospital falls occur. A prior study conducted before the system-wide introduction of preventive measures revealed a biphasic 24-hour pattern of hospital falls with major peak in the morning. The purpose was to identify the temporal patterning of falls among elderly patients in hospitals with comprehensive fall prevention programs in place. A 4-year observational study was conducted by the local health authority in the five nonteaching public hospitals located in the province of Ferrara, Italy. Fall records involving patients of ages ≥65 years hospitalized in the general medical departments were used. Single- and multiple-component cosinor (time series) analyses were used to explore 24-hour, weekly, and annual patterns of falls. A total of 763 falls were experienced by 709 different elderly hospitalized patients. Falls typically took place in the patient's hospital room (72%) and bathroom (23%). Major causes were patient instability (32%) and accident (13%), and most occurred when not wearing footwear (45%) or wearing inappropriate sling-back open-toe shoes (39%). Falls happened while standing (39%), while seated (21%), and while getting into, out of, or laying in bed (32%)-either with the bed rails raised or lowered. Fall outcome usually involved no injury (58%) or slight injury (35%), but some (7%) were disabling. Fall occurrence was higher during the night (46%) compared to either the morning (30%) or afternoon (24%) shift. Patterns across 24 hours were characterized by a single major and one or more minor peaks that seemed to be associated with a variety of scheduled patient, hospital, and nursing activities. Multiple-component cosinor analysis identified significant (p footwear. Falls were more frequent, but not significantly so, on Fridays, Sundays, and Mondays compared with Tuesdays, and were more frequent in winter and spring (p = .003). Documentation by cause and circumstance of