WorldWideScience

Sample records for fall protection systems

  1. Fall Protection Introduction, #33462

    Energy Technology Data Exchange (ETDEWEB)

    Chochoms, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    The proper use of fall prevention and fall protection controls can reduce the risk of deaths and injuries caused by falls. This course, Fall Protection Introduction (#33462), is designed as an introduction to various types of recognized fall prevention and fall protection systems at Los Alamos National Laboratory (LANL), including guardrail systems, safety net systems, fall restraint systems, and fall arrest systems. Special emphasis is given to the components, inspection, care, and storage of personal fall arrest systems (PFASs). This course also presents controls for falling object hazards and emergency planning considerations for persons who have fallen.

  2. A Fall Protection System for High-Rise Construction

    Directory of Open Access Journals (Sweden)

    Haluk Çeçen

    2013-01-01

    Full Text Available In construction industry, the number of fatal and nonfatal occupational injuries is higher than other industries. Among causes of these accidents, “falls” play a key role. This situation reveals the importance for carrying out research in fall protection systems. In this paper, a practical, economical, and functional fall protection system is introduced. Following determination and evaluation of existing solutions, weekly brainstorming meetings were held among the responsible project staff (general coordinator, project coordinator, project manager, site manager, and health and safety manager. As a result of these meetings, design criteria were developed. Based on these criteria, the fall protection system for high-rise construction (FPSFHC was developed which satisfied all the specified design criteria. Required materials were procured from local dealers. In this paper, criteria used in design and details of the final design are presented. Field performance of the system is evaluated, and recommendations for further development and standardization of the system are added.

  3. 75 FR 69369 - Walking-Working Surfaces and Personal Protective Equipment (Fall Protection Systems)

    Science.gov (United States)

    2010-11-12

    ... transmitting facsimile copies of attachments that supplement these documents (e.g., studies, journal articles...- Working Surfaces and Personal Protective Equipment (Fall Protection Systems) in general industry on... is an informal administrative proceeding convened to gather information and clarify the record. OSHA...

  4. 75 FR 28861 - Walking-Working Surfaces and Personal Protective Equipment (Fall Protection Systems)

    Science.gov (United States)

    2010-05-24

    ... Benefits and Cost Effectiveness of the Proposed Revision to OSHA's Walking-Working Standards Annualized... Part II Department of Labor Occupational Safety and Health Administration 29 CFR Part 1910 Walking... Walking-Working Surfaces and Personal Protective Equipment (Fall Protection Systems) AGENCY: Occupational...

  5. 29 CFR 1926.760 - Fall protection.

    Science.gov (United States)

    2010-07-01

    ..., safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems... feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge. The CDZ shall be marked by the use... protection equipment. (1) Guardrail systems, safety net systems, personal fall arrest systems, positioning...

  6. Collective Fall Protection for Construction Workers

    Directory of Open Access Journals (Sweden)

    Sulowski, A. C.

    2014-03-01

    Full Text Available Construction safety regulations require protection of workers against falls from elevations. The collective fall protection systems, in most cases, allow workers to move freely without wearing individual fall protection gear. The collective systems which prevent falls are preferred over the fall arrest systems. The latter are employed only if prevention of falls is not feasible. Arresting a fall always carries with it a residual risk of injury to the fall victim. The collective fall arrest systems are employed primarily during construction of electricity or telecomm towers. The aim of this paper has been a review of the collective FPS employed in the construction industry.Las normas de seguridad en la construcción requieren de protección para los trabajadores contra las caídas desde altura. Los Sistemas de Protección contra Caídas (FPS, por sus siglas en inglés colectivos, en la mayoría de los casos, permiten que los trabajadores se muevan libremente sin usar un equipo de protección contra caídas individual. Los sistemas colectivos de prevención de caídas son preferibles a los sistemas de detención de caídas, estos últimos se emplean sólo si la prevención de las caídas no es factible. La detención de una caída siempre lleva consigo un riesgo residual de lesiones en la víctima accidentada. Los sistemas colectivos de detención de caídas se emplean principalmente en la construcción de torres de electricidad o telecomunicaciones. El objetivo de este trabajo ha sido la revisión de los sistemas colectivos de protección contra caídas empleados en la industria de la construcción.

  7. Protect the Ones You Love From Falls

    Centers for Disease Control (CDC) Podcasts

    2008-12-10

    This podcast, developed as part of the Protect the Ones You Love initiative, discusses steps parents can take to help protect their children from falls, one of the leading causes of child injury.  Created: 12/10/2008 by National Center for Injury Prevention and Control (NCIPC).   Date Released: 12/10/2008.

  8. 29 CFR Appendix G to Subpart R of... - § 1926.502 (b)-(e) Fall Protection Systems Criteria and Practices

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false § 1926.502 (b)-(e) Fall Protection Systems Criteria and Practices G Appendix G to Subpart R of Part 1926 Labor Regulations Relating to Labor (Continued... FOR CONSTRUCTION Steel Erection Pt. 1926, Subpt. R, App. G Appendix G to Subpart R of Part 1926—§ 1926...

  9. 29 CFR Appendix C to Subpart M of... - Personal Fall Arrest Systems

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... fall distance should be supplied with the system, or in its absence, the least elastic lanyard or... considerations. (1) One of the most important aspects of personal fall protection systems is fully planning the...

  10. Safety yoke would protect construction workers from falling

    Science.gov (United States)

    Goforth, O. H.

    1967-01-01

    Simple dismountable yoke protects construction workers on narrow steel I beams at high levels. The yoke engages the upper flat of the I beam and slides freely along it to permit freedom of movement to the worker while limiting his ability to fall by a harness attached to the yoke.

  11. 29 CFR 1926.501 - Duty to have fall protection.

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection § 1926.501.../working surface 6 feet (1.8 m) or more above a lower level where leading edges are under construction, but... an employee must lean through the access opening or out over the edge of the access opening (to...

  12. Falls

    Science.gov (United States)

    ... falling off furniture or down the stairs. Older children may fall off playground equipment. For elderly people, falls can be especially serious. They are at higher risk of falling. They are also more likely to ...

  13. Development of rock fall prevention and protection technology

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, S. [Japan Coal Energy Center (Japan). Resources Dept.

    2006-03-15

    Rock falls are frequently occurring events in coal mines. They are profoundly influenced by the geological conditions of the coal mine and thus very difficult to prevent altogether. With the system that is being developed at present by JCOAL it will be possible to ascertain the roof conditions to some extent. Such prediction should make it possible to prevent major accidents that would otherwise claim lives. The use of this system is also capable of improving the efficiency of mining operations. The system under development involves a logging system for detecting cracks and discontinuities which consists of a Transmaster 1 bolting machine, a data logger and an analysis software program. Several methods are being researched to obtain data for predicting and monitoring rock fall. Field tests have been conducted at the Kushiro Coal Mine in Japan and the Ulan Coal Mine in NSW, Australia to gather data by PCs through the internet. Data from microtremors and P-wave velocities are being analysed to give early indication of rock fall. 5 refs., 7 figs.

  14. Evaluation of the falls telephone: an automated system for enduring assessment of falls.

    Science.gov (United States)

    van der Marck, Marjolein A; Overeem, Sebastiaan; Klok, Philomène C M; Bloem, Bastiaan R; Munneke, Marten

    2011-02-01

    To evaluate the reliability and user experiences of an automated telephone system to monitor falls during a prolonged period of time. Prospective cohort study. Four neurological outpatient clinics in the Netherlands. One hundred nineteen community-dwelling people with Parkinson's disease without dementia, because falls are common in this population. Clinical and demographic data were obtained. The Falls Telephone is a computerized telephone system through which participants can enter the number of falls during a particular period. During a follow-up of 1 to 40 weekly calls, 2,465 calls were made. In total, 173 no-fall entries and 115 fall entries were verified using personal telephone interviews. User experiences were evaluated in 90 of the 119 participants using structured telephone interviews. All no-fall entries and 78% of fall entries were confirmed to be correct. Sensitivity to detect falls was 100%, and specificity was 87%. Users regarded the Falls Telephone as a convenient tool to monitor falls. The Falls Telephone is a convenient and reliable instrument to monitor falls. The automated system has high specificity, obviating the need for time-consuming personal follow-up calls in the majority of nonfallers. As such, the Falls Telephone lends itself well to data collection in large trials with prolonged follow-up in participants with Parkinson's disease. © 2011, Copyright the Authors. Journal compilation © 2011, The American Geriatrics Society.

  15. Passive Cushiony Biomechanics of Head Protection in Falling Geckos

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2018-01-01

    Full Text Available Gekko geckos are capable to crawl on the steep even on upside-down surfaces. Such movement, especially at great altitude, puts them at high risks of incidentally dropping down and inevitable body or head impactions, though they may trigger air-righting reaction (ARR to attenuate the landing shocks. However, the air-righting ability (ARA in Gekko geckos is not fully developed. The implementation of ARR in some geckos is quite slow; and for those without tails, the ARR is even unobservable. Since ARA is compromised in Gekko geckos, there must be some other mechanisms responsible for protecting them from head injuries during falls. In this study, we looked into a Gekko gecko’s brain to study its internal environment and structure, using the magnetic resonance imaging (MRI technique. The results showed that the brain parenchyma was fully surrounded by the cerebrospinal fluid (CSF in the skull. A succulent characteristic was presented, which meant the intracalvarium was significantly occupied by the CSF, up to 45% in volume. Then a simplified three-dimensional finite element model was built, and a dynamic simulation was conducted to evaluate the mechanical property of this succulent characteristic during the head impactions. These implied the succulent characteristic may play certain roles on the self-protection in case of head impaction, which is adaptable to the Gekko gecko’s locomotion and behavior.

  16. 29 CFR 1926.759 - Falling object protection.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.759 Falling object... materials being hoisted. The controlling contractor shall bar other construction processes below steel...

  17. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2014

    International Nuclear Information System (INIS)

    2014-11-01

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2014. It was held on Nov.19-21, 2014 in Jeju, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2014. This proceedings is comprised of 8 sessions. The main topic titles of session are as follows: Radiation protection 1, Medical treatment and Biology 1, Radiation measurement 1, Radiation environment and protection 1, Radiation protection 2, Medical treatment and Biology 2, Radiation Measurement 2, Radiation environment and protection 2

  18. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2016

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-12-15

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2016. It was held on Dec. 1, 2016 Phoenix Island in Jeju, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2016. This proceedings is comprised of 5 sessions. The main topic titles of session are as follows: Radiation protection, Biotechnology of radiation, Radiation measurement, Radiation environment and prevention, Radiation epidemiography.

  19. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2016

    International Nuclear Information System (INIS)

    2016-12-01

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2016. It was held on Dec. 1, 2016 Phoenix Island in Jeju, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2016. This proceedings is comprised of 5 sessions. The main topic titles of session are as follows: Radiation protection, Biotechnology of radiation, Radiation measurement, Radiation environment and prevention, Radiation epidemiography.

  20. Fall protection characteristics of safety belts and human impact tolerance.

    Science.gov (United States)

    Hino, Yasumichi; Ohdo, Katsutoshi; Takahashi, Hiroki

    2014-01-01

    Many fatal accidents due to falls from heights have occurred at construction sites not only in Japan but also in other countries. This study aims to determine the fall prevention performance of two types of safety belts: a body belt, which has been used for more than 40 yr in the Japanese construction industry as a general type of safety equipment for fall accident prevention, and a full harness, which has been used in many other countries. To determine human tolerance for impact trauma, this study discusses features of safety belts with reference to relevant studies in the medical science, automobile crash safety, and aircrew safety. For this purpose, simple drop tests were carried out in a virtual workplace to measure impact load, head acceleration, and posture in the experiments, the Hybrid-III pedestrian model was used as a human dummy. Hybrid-III is typically employed in official automobile crash tests (New Car Assessment Program: NCAP) and is currently recognized as a model that faithfully reproduces dynamic responses. Experimental results shows that safety performance strongly depends on both the variety of safety belts used and the shock absorbers attached onto lanyards. These findings indicate that fall prevention equipment, such as safety belts, lanyards, and shock absorbers, must be improved to reduce impact injuries to the human head and body during falls.

  1. Fall Protection Characteristics of Safety Belts and Human Impact Tolerance.

    Science.gov (United States)

    Hino, Yasumichi; Ohdo, Katsutoshi; Takahashi, Hiroki

    2014-08-23

    Many fatal accidents due to falls from heights have occurred at construction sites not only in Japan but also in other countries. This study aims to determine the fall prevention performance of two types of safety belts: a body belt 1) , which has been used for more than 40 yr in the Japanese construction industry as a general type of safety equipment for fall accident prevention, and a full harness 2, 3) , which has been used in many other countries. To determine human tolerance for impact trauma, this study discusses features of safety belts with reference 4-9) to relevant studies in the medical science, automobile crash safety, and aircrew safety. For this purpose, simple drop tests were carried out in a virtual workplace to measure impact load, head acceleration, and posture in the experiments, the Hybrid-III pedestrian model 10) was used as a human dummy. Hybrid-III is typically employed in official automobile crash tests (New Car Assessment Program: NCAP) and is currently recognized as a model that faithfully reproduces dynamic responses. Experimental results shows that safety performance strongly depends on both the variety of safety belts used and the shock absorbers attached onto lanyards. These findings indicate that fall prevention equipment, such as safety belts, lanyards, and shock absorbers, must be improved to reduce impact injuries to the human head and body during falls.

  2. Proceedings of the Conference and Symposium Korean Association for Radiation Protection Fall Meeting 2015

    International Nuclear Information System (INIS)

    2015-10-01

    This proceedings contains articles of the Korean Association for Radiation Protection Fall Meeting, 2015. It was held on Oct.23, 2015 Mayfield Hotel in Seoul, Korea and subject of the Korean Association for Radiation Protection Fall Meeting 2015. This proceedings is comprised of 8 sessions. The main topic titles of session are as follows: Radiation protection 1, Medical treatment and Biology 1, Radiation Measurement 1, Radiation environment and disasters prevention 1, Radiation protection 2, Medical treatment and Biology 2, Radiation Measurement 2, Radiation environment and disasters prevention 2

  3. Development and evaluation of an automated fall risk assessment system.

    Science.gov (United States)

    Lee, Ju Young; Jin, Yinji; Piao, Jinshi; Lee, Sun-Mi

    2016-04-01

    Fall risk assessment is the first step toward prevention, and a risk assessment tool with high validity should be used. This study aimed to develop and validate an automated fall risk assessment system (Auto-FallRAS) to assess fall risks based on electronic medical records (EMRs) without additional data collected or entered by nurses. This study was conducted in a 1335-bed university hospital in Seoul, South Korea. The Auto-FallRAS was developed using 4211 fall-related clinical data extracted from EMRs. Participants included fall patients and non-fall patients (868 and 3472 for the development study; 752 and 3008 for the validation study; and 58 and 232 for validation after clinical application, respectively). The system was evaluated for predictive validity and concurrent validity. The final 10 predictors were included in the logistic regression model for the risk-scoring algorithm. The results of the Auto-FallRAS were shown as high/moderate/low risk on the EMR screen. The predictive validity analyzed after clinical application of the Auto-FallRAS was as follows: sensitivity = 0.95, NPV = 0.97 and Youden index = 0.44. The validity of the Morse Fall Scale assessed by nurses was as follows: sensitivity = 0.68, NPV = 0.88 and Youden index = 0.28. This study found that the Auto-FallRAS results were better than were the nurses' predictions. The advantage of the Auto-FallRAS is that it automatically analyzes information and shows patients' fall risk assessment results without requiring additional time from nurses. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  4. System level ESD protection

    CERN Document Server

    Vashchenko, Vladislav

    2014-01-01

    This book addresses key aspects of analog integrated circuits and systems design related to system level electrostatic discharge (ESD) protection.  It is an invaluable reference for anyone developing systems-on-chip (SoC) and systems-on-package (SoP), integrated with system-level ESD protection. The book focuses on both the design of semiconductor integrated circuit (IC) components with embedded, on-chip system level protection and IC-system co-design. The readers will be enabled to bring the system level ESD protection solutions to the level of integrated circuits, thereby reducing or completely eliminating the need for additional, discrete components on the printed circuit board (PCB) and meeting system-level ESD requirements. The authors take a systematic approach, based on IC-system ESD protection co-design. A detailed description of the available IC-level ESD testing methods is provided, together with a discussion of the correlation between IC-level and system-level ESD testing methods. The IC-level ESD...

  5. Buffer moisture protection system

    International Nuclear Information System (INIS)

    Ritola, J.; Peura, J.

    2013-11-01

    With the present knowledge, bentonite blocks have to be protected from the air relative humidity and from any moisture leakages in the environment that might cause swelling of the bentonite blocks during the 'open' installation phase before backfilling. The purpose of this work was to design the structural reference solution both for the bottom of the deposition hole and for the buffer moisture protection and dewatering system with their integrated equipment needed in the deposition hole. This report describes the Posiva's reference solution for the buffer moisture protection system and the bottom plate on basis of the demands and functional requirements set by long-term safety. The reference solution with structural details has been developed in research work made 2010-2011. The structural solution of the moisture protection system has not yet been tested in practice. On the bottom of the deposition hole a copper plate which protects the lowest bentonite block from the gathered water is installed straight to machined and even rock surface. The moisture protection sheet made of EPDM rubber is attached to the copper plate with an inflatable seal. The upper part of the moisture protection sheet is fixed to the collar structures of the lid which protects the deposition hole in the disposal tunnel. The main function of the moisture protection sheet is to protect bentonite blocks from the leaking water and from the influence of the air humidity at their installation stage. The leaking water is controlled by the dewatering and alarm system which has been integrated into the moisture protection liner. (orig.)

  6. A novel wearable smart button system for fall detection

    Science.gov (United States)

    Zhuang, Wei; Sun, Xiang; Zhi, Yueyan; Han, Yue; Mao, Hande

    2017-05-01

    Fall has been the second most cause of accidental injury to death in the world. It has been a serious threat to the physical and mental health of the elders. Therefore, developing wearable node system with fall detecting ability has become increasingly pressing at present. A novel smart button for long-term fall detection is proposed in this paper, which is able to accurately monitor the falling behavior, and sending warning message online as well. The smart button is based on the tri-axis acceleration sensor which is used to collect the body motion signals. By using the statistical metrics of acceleration characteristics, a new SVM classification algorithm with high positive accuracy and stability is proposed so as to classify the falls and activities of daily living, and the results can be real-time displayed on Android based mobile phone. The experiments show that our wearable node system can continuously monitor the falling behavior with positive rate 94.8%.

  7. Power system protection

    International Nuclear Information System (INIS)

    Venkata, S.S.; Damborg, M.J.; Jampala, A.K.

    1991-01-01

    Power systems of the 21st century will be more modern, and complex, utilizing the latest available technologies. At the same time, generating plants will have to operate with minimal spinning margins and energy transportation has to take place at critical levels due to environmental and economical constraints. These factors dictate that the power systems be protected with optimum sensitivity, selectivity and time of operation to assure maximum reliability, and security at minimal cost. With an increasing role played by digital computers in every aspect of protection, it is important to take a critical and fresh look at the art and science of relaying and protection. The main objective of this paper is to review the past, present and future of power system protection from a software point of view

  8. Fall Down Detection Under Smart Home System.

    Science.gov (United States)

    Juang, Li-Hong; Wu, Ming-Ni

    2015-10-01

    Medical technology makes an inevitable trend for the elderly population, therefore the intelligent home care is an important direction for science and technology development, in particular, elderly in-home safety management issues become more and more important. In this research, a low of operation algorithm and using the triangular pattern rule are proposed, then can quickly detect fall-down movements of humanoid by the installation of a robot with camera vision at home that will be able to judge the fall-down movements of in-home elderly people in real time. In this paper, it will present a preliminary design and experimental results of fall-down movements from body posture that utilizes image pre-processing and three triangular-mass-central points to extract the characteristics. The result shows that the proposed method would adopt some characteristic value and the accuracy can reach up to 90 % for a single character posture. Furthermore the accuracy can be up to 100 % when a continuous-time sampling criterion and support vector machine (SVM) classifier are used.

  9. Smart Machine Protection System

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.; Spencer, N.; Hutchinson, D.; Olsen, J.; Millsom, D.; White, G.; Gromme, T.; Allison, S.; Underwood, K.; Zelazny, M.; Kang, H.

    1991-11-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerator to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is compiled into a logical decision tree for the 68030 processor. 3 figs

  10. Smart machine protection system

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.

    1992-01-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerators to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is complied into a logical decision tree for the 68030 processor. (author)

  11. Protective and Catching Safety Systems In Construction

    Directory of Open Access Journals (Sweden)

    Kuzhin Marat

    2017-01-01

    Full Text Available In the article is described application of protective and catching systems in construction. Classification of similar systems, their types and purpose are listed. Dangerous zones on construction site and events to for limiting their influence or protection from the factors. Protective and catching systems is one of the most effective technical equipment, applied in recent time. Protective fences and catching systems are important part in the problem solution. Protective fences protect workers from falling from height. Protective and catching systems allows avoid injuries by workers, also catch debris, fallen from constructing buildings. In regard with continuing development in technical and technological solutions, protective and catching systems require adaptation to a new requirements of construction industry and requirements of normative documents. Technical regulations in the appliance sphere of protective and catching systems requires actualization and aligning with modern normatives. Important role should be given to developing organizational and technological documentation for application of the systems. Scientific studying of technical parameters of fences and protective catching nets also has great interest.

  12. Fall Protection Procedures for Sealing Bulk Waste Shipments by Rail Cars at Formerly Utilized Sites Remedial Action Program (FUSRAP) Sites - 13509

    International Nuclear Information System (INIS)

    Boyle, J.D.; Fort, E. Joseph; Lorenz, William; Mills, Andy

    2013-01-01

    Rail-cars loaded with radioactive materials must be closed and fastened to comply with United States Department of Transportation (DOT) requirements before they shipped. Securing waste shipments in a manner that meets these regulations typically results in the use of a sealable rail-car liner. Workers accessing the tops of the 2.74 m high rail-cars to seal and inspect liners for compliance prior to shipment may be exposed to a fall hazard. Relatively recent revisions to the Fall Protection requirements in the Safety and Health Requirements Manual (EM385-1-1, U.S. Army Corps of Engineers) have necessitated modifications to the fall protection systems previously employed for rail-car loading at Formerly Utilized Sites Remedial Action Program (FUSRAP) sites. In response these projects have developed site-specific procedures to protect workers and maintain compliance with the improved fall protection regulations. (authors)

  13. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration

  14. Evaluation of the falls telephone: an automated system for enduring assessment of falls

    NARCIS (Netherlands)

    Marck, M.A. van der; Overeem, S.; Klok, P.C.; Bloem, B.R.; Munneke, M.

    2011-01-01

    OBJECTIVES: To evaluate the reliability and user experiences of an automated telephone system to monitor falls during a prolonged period of time. DESIGN: Prospective cohort study. SETTING: Four neurological outpatient clinics in the Netherlands. PARTICIPANTS: One hundred nineteen community-dwelling

  15. Digital integrated protection system

    International Nuclear Information System (INIS)

    Savornin, M.; Furet, M.

    1978-01-01

    As a result of technological progress it is now possible to achieve more elaborate protection functions able to follow more closely the phenomena to be supervised. For this reason the CEA, Framatome and Merlin/Gerin/CERCI have undertaken in commonn to develop a Digital Integrated Protection System (D.I.P.S.). This system is designed with the following aims: to improve the safety of the station, . to improve its availability, . to facilitate installation, . to facilitate tests and maintenance. The main characteristics adopted are: . possibilities of obtaining more elaborate monitoring and protection algorithm treatments, . order 4 redundancy of transducers, associated instruments and signal processing, . possibility of inhibiting part of the protection system, . standardisation of equipment, physical and electrical separation of redundant units, . use of multiplexed connections, . automation of tests. Four flow charts are presented: - DIPS with four APUP (Acquisition and Processing Unit for Protection) - APUP - LSU (Logic Safeguard Unit), number LSU corresponding to number fluidic safeguard circuits, - structure of a function unit, - main functions of the APUP [fr

  16. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment

  17. Analysis of NPP protection structure reliability under impact of a falling aircraft

    International Nuclear Information System (INIS)

    Shul'man, G.S.

    1996-01-01

    Methodology for evaluation of NPP protection structure reliability by impact of aircraft fall down is considered. The methodology is base on the probabilistic analysis of all potential events. The problem is solved in three stages: determination of loads on structural units, calculation of local reliability of protection structures by assigned loads and estimation of the structure reliability. The methodology proposed may be applied at the NPP design stage and by determination of reliability of already available structures

  18. Drilling through Conservation Policy: Oil Exploration in Murchison Falls Protected Area, Uganda

    Directory of Open Access Journals (Sweden)

    Catrina A MacKenzie

    2017-01-01

    Full Text Available Approximately 2.5 billion barrels of commercially-viable oil, worth $2 billion in annual revenue for 20 years, were discovered under the Ugandan portion of the Albertine Rift in 2006. The region also contains seven of Uganda's protected areas and a growing ecotourism industry. We conducted interviews and focus groups in and around Murchison Falls Protected Area, Uganda's largest, oldest, and most visited protected area, to assess the interaction of oil exploration with the three primary conservation policies employed by Uganda Wildlife Authority: protectionism, neoliberal capital accumulation, and community-based conservation. We find that oil extraction is legally permitted inside protected areas in Uganda, like many other African countries, and that the wildlife authority and oil companies are adapting to co-exist inside a protected area. Our primary argument is that neoliberal capital accumulation as a conservation policy actually makes protected areas more vulnerable to industrial exploitation because nature is commodified, allowing economic value and profitability of land uses to determine how nature is exploited. Our secondary argument is that the conditional nature of protected area access inherent within the protectionist policy permits oil extraction within Murchison Falls Protected Area. Finally, we argue that community-based conservation, as operationalized in Uganda, has no role in defending protected areas against oil industrialisation.

  19. Protective garment ventilation system

    Science.gov (United States)

    Lang, R. (Inventor)

    1970-01-01

    A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

  20. The fall and rise of micropayment systems

    NARCIS (Netherlands)

    Parhonyi, R.; Nieuwenhuis, Lambertus Johannes Maria; Pras, Aiko; Lammer, T.

    2006-01-01

    In this article, we discuss the chance that the second generation systems will become more successful than their predecessors and to what extent do these sys-tems solve or avoid problems causing the failure of the first generation systems. We show that most failure causes are avoided in the second

  1. ADVANCED WORKER PROTECTION SYSTEM

    International Nuclear Information System (INIS)

    Judson Hedgehock

    2001-01-01

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  2. ADVANCED WORKER PROTECTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Judson Hedgehock

    2001-03-16

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  3. Gamma radiation and gamma ray protection factors of ships in various situations of radioactive fall-out

    International Nuclear Information System (INIS)

    Brehm, E.H.; Holst, T.

    1975-01-01

    In this report the development of methods of evaluating gamma ray protection factors (GSF) of ships for various situations of radioactive fall-out is described. The joining calculations of gamma ray protection factors are performed by the newly developed computer procedure GASUFA. These protection factors determine - in connection with a measured gamma radiation dose at a given detector point - the gamma radiation in different compartments of the ships. The computer program GASUFA is able to perform calculations considering the dependence of energy, place and time for the following situations: - the ship is under a radioactive cloud without fall-out; - the ship is under a radioactive cloud with fall-out; - the ship is contaminated by radioactive fall-out; - the clean or decontaminated ship is going through a zone, which is contaminated by radioactive fall-out; - the ship and the surrounding water surface are contaminated by radioactive fall-out. (orig.) [de

  4. Fall 2014 Data-Intensive Systems

    Science.gov (United States)

    2014-10-29

    Oct 2014 © 2014 Carnegie Mellon University Big Data Systems NoSQL and horizontal scaling are changing architecture principles by creating...University Status LEAP4BD • Ready to pilot QuABase • Prototype is complete – covers 8 NoSQL /NewSQL implementations • Completing validation testing Big...machine learning to automate population of knowledge base • Initial focus on NoSQL /NewSQL technology domain • Extend to create knowledge bases in other

  5. Analysis of Public Datasets for Wearable Fall Detection Systems.

    Science.gov (United States)

    Casilari, Eduardo; Santoyo-Ramón, José-Antonio; Cano-García, José-Manuel

    2017-06-27

    Due to the boom of wireless handheld devices such as smartwatches and smartphones, wearable Fall Detection Systems (FDSs) have become a major focus of attention among the research community during the last years. The effectiveness of a wearable FDS must be contrasted against a wide variety of measurements obtained from inertial sensors during the occurrence of falls and Activities of Daily Living (ADLs). In this regard, the access to public databases constitutes the basis for an open and systematic assessment of fall detection techniques. This paper reviews and appraises twelve existing available data repositories containing measurements of ADLs and emulated falls envisaged for the evaluation of fall detection algorithms in wearable FDSs. The analysis of the found datasets is performed in a comprehensive way, taking into account the multiple factors involved in the definition of the testbeds deployed for the generation of the mobility samples. The study of the traces brings to light the lack of a common experimental benchmarking procedure and, consequently, the large heterogeneity of the datasets from a number of perspectives (length and number of samples, typology of the emulated falls and ADLs, characteristics of the test subjects, features and positions of the sensors, etc.). Concerning this, the statistical analysis of the samples reveals the impact of the sensor range on the reliability of the traces. In addition, the study evidences the importance of the selection of the ADLs and the need of categorizing the ADLs depending on the intensity of the movements in order to evaluate the capability of a certain detection algorithm to discriminate falls from ADLs.

  6. Analysis of Public Datasets for Wearable Fall Detection Systems

    Directory of Open Access Journals (Sweden)

    Eduardo Casilari

    2017-06-01

    Full Text Available Due to the boom of wireless handheld devices such as smartwatches and smartphones, wearable Fall Detection Systems (FDSs have become a major focus of attention among the research community during the last years. The effectiveness of a wearable FDS must be contrasted against a wide variety of measurements obtained from inertial sensors during the occurrence of falls and Activities of Daily Living (ADLs. In this regard, the access to public databases constitutes the basis for an open and systematic assessment of fall detection techniques. This paper reviews and appraises twelve existing available data repositories containing measurements of ADLs and emulated falls envisaged for the evaluation of fall detection algorithms in wearable FDSs. The analysis of the found datasets is performed in a comprehensive way, taking into account the multiple factors involved in the definition of the testbeds deployed for the generation of the mobility samples. The study of the traces brings to light the lack of a common experimental benchmarking procedure and, consequently, the large heterogeneity of the datasets from a number of perspectives (length and number of samples, typology of the emulated falls and ADLs, characteristics of the test subjects, features and positions of the sensors, etc.. Concerning this, the statistical analysis of the samples reveals the impact of the sensor range on the reliability of the traces. In addition, the study evidences the importance of the selection of the ADLs and the need of categorizing the ADLs depending on the intensity of the movements in order to evaluate the capability of a certain detection algorithm to discriminate falls from ADLs.

  7. New Advances and Challenges of Fall Detection Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Tao Xu

    2018-03-01

    Full Text Available Falling, as one of the main harm threats to the elderly, has drawn researchers’ attentions and has always been one of the most valuable research topics in the daily health-care for the elderly in last two decades. Before 2014, several researchers reviewed the development of fall detection, presented issues and challenges, and navigated the direction for the study in the future. With smart sensors and Internet of Things (IoT developing rapidly, this field has made great progress. However, there is a lack of a review and discussion on novel sensors, technologies and algorithms introduced and employed from 2014, as well as the emerging challenges and new issues. To bridge this gap, we present an overview of fall detection research and discuss the core research questions on this topic. A total of 6830 related documents were collected and analyzed based on the key words. Among these documents, the twenty most influential and highly cited articles are selected and discussed profoundly from three perspectives: sensors, algorithms and performance. The findings would assist researchers in understanding current developments and barriers in the systems of fall detection. Although researchers achieve fruitful work and progress, this research domain still confronts challenges on theories and practice. In the near future, the new solutions based on advanced IoT will sustainably urge the development to prevent falling injuries.

  8. Risk and protective factors for falls from furniture in young children: multicenter case-control study.

    Science.gov (United States)

    Kendrick, Denise; Maula, Asiya; Reading, Richard; Hindmarch, Paul; Coupland, Carol; Watson, Michael; Hayes, Mike; Deave, Toity

    2015-02-01

    Falls from furniture are common in young children but there is little evidence on protective factors for these falls. To estimate associations for risk and protective factors for falls from furniture in children aged 0 to 4 years. Multicenter case-control study at hospitals, minor injury units, and general practices in and around 4 UK study centers. Recruitment commenced June 14, 2010, and ended April 27, 2012. Participants included 672 children with falls from furniture and 2648 control participants matched on age, sex, calendar time, and study center. Thirty-five percent of cases and 33% of control individuals agreed to participate. The mean age was 1.74 years for cases and 1.91 years for control participants. Fifty-four percent of cases and 56% of control participants were male. Exposures included safety practices, safety equipment use, and home hazards. Falls from furniture occurring at the child's home resulting in attendance at an emergency department, minor injury unit, or hospital admission. Compared with parents of control participants, parents of cases were significantly more likely not to use safety gates in the home (adjusted odds ratio [AOR], 1.65; 95% CI, 1.29-2.12) and not to have taught their children rules about climbing on kitchen objects (AOR, 1.58; 95% CI, 1.16-2.15). Cases aged 0 to 12 months were significantly more likely to have been left on raised surfaces (AOR, 5.62; 95% CI, 3.62-8.72), had their diapers changed on raised surfaces (AOR, 1.89; 95% CI, 1.24-2.88), and been put in car/bouncing seats on raised surfaces (AOR, 2.05; 95% CI, 1.29-3.27). Cases 3 years and older were significantly more likely to have played or climbed on furniture (AOR, 9.25; 95% CI, 1.22-70.07). Cases were significantly less likely to have played or climbed on garden furniture (AOR, 0.74; 95% CI, 0.56-0.97). If estimated associations are causal, some falls from furniture may be prevented by incorporating advice into child health contacts, personal child health

  9. Lightning protection of PV systems

    OpenAIRE

    Pons, Enrico; Tommasini, Riccardo

    2013-01-01

    Lightning strikes can affect photovoltaic (PV) generators and their installations, involving also the inverter's electronics. It is therefore necessary to evaluate the risk connected to lightning strikes in order to adopt the correct protective measures for the system. The Standard IEC (EN) 62305-2 reports the procedures for the risk calculation and for the choice of proper lightning protection systems. Usually the technical guidelines suggest protecting with SPDs (surge protective devices) b...

  10. FIRE PROTECTION SYSTEMS AND TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Aristov Denis Ivanovich

    2016-03-01

    Full Text Available The All-Russian Congress “Fire Stop Moscow” was de-voted to the analysis of the four segments of the industry of fire protection systems and technologies: the design of fire protec-tion systems, the latest developments and technologies of active and passive fire protection of buildings, the state and the devel-opment of the legal framework, the practice of fire protection of buildings and structures. The forum brought together the repre-sentatives of the industry of fire protection systems, scientists, leading experts, specialists in fire protection and representatives of construction companies from different regions of Russia. In parallel with the Congress Industrial Exhibition of fire protection systems, materials and technology was held, where manufacturers presented their products. The urgency of the “Fire Stop Moscow” Congress in 2015 organized by the Congress Bureau ODF Events lies primarily in the fact that it considered the full range of issues related to the fire protection of building and construction projects; studied the state of the regulatory framework for fire safety and efficiency of public services, research centers, private companies and busi-nesses in the area of fire safety. The main practical significance of the event which was widely covered in the media space, was the opportunity to share the views and information between management, science, and practice of business on implementing fire protection systems in the conditions of modern economic relations and market realities. : congress, fire protection, systems, technologies, fire protection systems, exhibition

  11. Effect of the "squat protective response" on impact velocity during backward falls.

    Science.gov (United States)

    Robinovitch, Stephen N; Brumer, Rebecca; Maurer, Jessica

    2004-09-01

    Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend on the time during descent when the response is initiated. We tested this hypothesis by conducting backward falling experiments with young women (n = 23; aged 21-29 years), who fell onto a soft gymnasium mattress after being suddenly releasing from an inclined position. In trials where subjects were released from a 5 degrees lean, average impact velocities were reduced by 18% when squatting was utilized as opposed to inhibited. Furthermore, increases in the release angle caused an increase in average impact velocity of 8% between lean angles of 2 degrees and 5 degrees, and 7% between lean angles of 5 degrees and 12 degrees. This was due to declines in peak extensor torques and peak flexion rotations, and corresponding reductions in both joint work and potential energy at impact. These results suggest that squatting during descent reduces impact severity, but the effectiveness of the response depends on the stage during descent when it is initiated, diminishing in benefit as the fall progresses and the state of imbalance grows increasingly severe.

  12. Geothermal District Heating System City of Klamath Falls

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, Paul J.; Rafferty, Kevin

    1991-12-01

    The city of Klamath Falls became interested in the possibility of a establishing geothermal district heating system for downtown government buildings in January 1977. Since that time, the project has undergone some controversial and interesting developments that may be of educational value to other communities contemplating such a project. The purpose and content of this article is to identify the historical development of the project; including the design of the system, well owner objections to the project, aquifer testing, piping failure, and future expansion and marketing incentives. The shallow geothermal reservoir in Klamath falls extends for at least 6.8 miles in a northwest-southeast direction, as shown on Figure 1, with a width of about 2 miles. More than 550 thermal wells ranging in depth from about 10 to 2,000 ft, and obtaining or contacting water from 70 to 230oF, have been drilled into the reservoir. The system is not geologically homogeneous. Great variations in horizontal permeability and many vertical discontinuities exist because of stratigraphy and structure of the area. Basalt flows, eruptive centers, fluvial and lacustrine deposits, diatomite and pyroclastic materials alternate in the rock column. Normal faults with large throw (estimated up to 1,700 ft) are spaced less than 3,300 ft apart and appear to be the main avenue of vertical movement of hot fluids. In order to more effectively utilize this resource, the city of Klamath Falls decided in 1978 to apply for a federal grant (Program Opportunity Notice to cost share field experiment projects) to construct a geothermal district heating system that would deliver geothermal fluids to areas not located on the resource. In 1977, several Geo-Heat Center staff members visited Reykjavik, Iceland, to study the design of their geothermal district heating systems. This was in part the basis for the conceptual design and feasibility study (Lund, 1979) of a downtown commercial district. The main difference

  13. Risk and protective factors for falls on stairs in young children: multicentre case-control study.

    Science.gov (United States)

    Kendrick, D; Zou, K; Ablewhite, J; Watson, M; Coupland, C; Kay, B; Hawkins, A; Reading, R

    2016-10-01

    To investigate risk and protective factors for stair falls in children aged children with medically attended stair fall injuries. Controls were matched on age, sex, calendar time and study centre. A total of 610 cases and 2658 controls participated. Cases' most common injuries were bangs on the head (66%), cuts/grazes not requiring stitches (14%) and fractures (12%). Parents of cases were significantly more likely not to have stair gates (adjusted OR (AOR) 2.50, 95% CI 1.90 to 3.29; population attributable fraction (PAF) 21%) or to leave stair gates open (AOR 3.09, 95% CI 2.39 to 4.00; PAF 24%) both compared with having closed stair gates. They were more likely not to have carpeted stairs (AOR 1.52, 95% CI 1.09 to 2.10; PAF 5%) and not to have a landing part-way up their stairs (AOR 1.34, 95% CI 1.08 to 1.65; PAF 18%). They were more likely to consider their stairs unsafe to use (AOR 1.46, 95% CI 1.07 to 1.99; PAF 5%) or to be in need of repair (AOR 1.71, 95% CI 1.16 to 2.50; PAF 5%). Structural factors including having landings part-way up the stairs and keeping stairs in good repair were associated with reduced stair fall injury risk. Family factors including having stair gates, not leaving gates open and having stair carpets were associated with reduced injury risk. If these associations are causal, addressing these factors in housing policy and routine child health promotion could reduce stair fall injuries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Protection of industrial power systems

    CERN Document Server

    DAVIES, T

    2006-01-01

    The protection which is installed on an industrial power system is likely to be subjected to more difficult conditions than the protection on any other kind of power system. Starting with the many simple devices which are employed and covering the whole area of industrial power system protection, this book aims to help achieve a thorough understanding of the protection necessary.Vital aspects such as the modern cartridge fuse, types of relays, and the role of the current transformer are covered and the widely used inverse definite-minimum time overcurrent relay, the theory of the M

  15. Identifying protective and risk factors for injurious falls in patients hospitalized for acute care: a retrospective case-control study

    Directory of Open Access Journals (Sweden)

    Emmanuel Aryee

    2017-11-01

    Full Text Available Abstract Background Admitted patients who fall and injure themselves during an acute hospitalization incur increased costs, morbidity, and mortality, but little research has been conducted on identifying inpatients at high risk to injure themselves in a fall. Falls risk assessment tools have been unsuccessful due to their low positive predictive value when applied broadly to entire hospital populations. We aimed to identify variables associated with the risk of or protection against injurious fall in the inpatient setting. We also aimed to test the variables in the ABCs mnemonic (Age > 85, Bones-orthopedic conditions, anti-Coagulation and recent surgery for correlation with injurious fall. Methods We performed a retrospective case-control study at an academic tertiary care center comparing admitted patients with injurious fall to admitted patients without fall. We collected data on the demographics, medical and fall history, outcomes, and discharge disposition of injured fallers and control patients. We performed multivariate analysis of potential risk factors for injurious fall with logistic regression to calculate adjusted odds ratios. Results We identified 117 injured fallers and 320 controls. There were no differences in age, anti-coagulation use or fragility fractures between cases and controls. In multivariate analysis, recent surgery (OR 0.46, p = 0.003 was protective; joint replacement (OR 5.58, P = 0.002, psychotropic agents (OR 2.23, p = 0.001, the male sex (OR 2.08, p = 0.003 and history of fall (OR 2.08, p = 0.02 were significantly associated with injurious fall. Conclusion In this study, the variables in the ABCs parameters were among the variables not useful for identifying inpatients at risk of injuring themselves in a fall, while other non-ABCs variables demonstrated a significant association with injurious fall. Recent surgery was a protective factor, and practices around the care of surgical patients could be

  16. Automatic reactor protection system tester

    International Nuclear Information System (INIS)

    Deliant, J.D.; Jahnke, S.; Raimondo, E.

    1988-01-01

    The object of this paper is to present the automatic tester of reactor protection systems designed and developed by EDF and Framatome. In order, the following points are discussed: . The necessity for reactor protection system testing, . The drawbacks of manual testing, . The description and use of the Framatome automatic tester, . On-site installation of this system, . The positive results obtained using the Framatome automatic tester in France

  17. Occlusion, optimization, emergency response and partial falls in a senior collapse detection system

    Science.gov (United States)

    Grewe, Lynne; Magaña-Zook, Steven

    2015-05-01

    Vision based fall detection systems must often contend with more issues than the need to simply identify true fall cases. All vision systems have areas of the frame they cannot see, occlusion, and this becomes of critical importance for systems monitoring for falls. Even with full scene visibility, human falls have an incredible variety requiring special detectors for edge cases like partial falls. Each detection algorithm is only as good as the parameters it is provided and so optimum values for each detector are found using Particle Swarm Optimization. We then discuss the use of email and short message service (SMS) in alerting caregivers that a fall has occurred.

  18. Corrosion of connectors used in equipment protecting against falls from a height.

    Science.gov (United States)

    Jachowicz, Marcin

    2015-01-01

    Connectors are commonly found in personal equipment protecting against falls from a height. They are typically used outdoors and exposed to atmospheric factors, which can result in corrosion. This article presents the results of a study involving exposure of connectors to experimental corrosive media - neutral salt spray (NSS), acid salt spray (ASS), and seawater mist (for elements made of carbon steel and non-ferrous metals) - and to experimental conditions simulating the processes of pitting, stress, and intercrystalline corrosion (for equipment made of s`tainless steel). The results indicate that the main effects of corrosion on connectors include impaired operation and reduced strength of their mobile elements. The article presents methods of testing connector operation developed for this purpose. Corrosive damage to connectors has been presented in relation to potential hazards for their users.

  19. SMART core protection system design

    International Nuclear Information System (INIS)

    Lee, J. K.; Park, H. Y.; Koo, I. S.; Park, H. S.; Kim, J. S.; Son, C. H.

    2003-01-01

    SMART COre Protection System(SCOPS) is designed with real-tims Digital Signal Processor(DSP) board and Network Interface Card(NIC) board. SCOPS has a Control Rod POSition (CRPOS) software module while Core Protection Calculator System(CPCS) consists of Core Protection Calculators(CPCs) and Control Element Assembly(CEA) Calculators(CEACs) in the commercial nuclear plant. It's not necessary to have a independent cabinets for SCOPS because SCOPS is physically very small. Then SCOPS is designed to share the cabinets with Plant Protection System(PPS) of SMART. Therefor it's very easy to maintain the system because CRPOS module is used instead of the computer with operating system

  20. ICT-based system to predict and prevent falls (iStoppFalls): study protocol for an international multicenter randomized controlled trial

    OpenAIRE

    Gschwind, Yves J.; Eichberg, Sabine; Marston, Hannah R.; Ejupi, Andreas; De Rosario Martínez, Helios; Kroll, Michael; Drobics, Mario; Annegarn, Janneke; Wieching, Rainer; Lord, Stephen R.; Aal, Konstantin; Delbaere, Kim

    2014-01-01

    Background: Falls are very common, especially in adults aged 65 years and older. Within the current international European Commission's Seventh Framework Program (FP7) project 'iStoppFalls' an Information and Communication Technology (ICT) based system has been developed to regularly assess a person's risk of falling in their own home and to deliver an individual and tailored home-based exercise and education program for fall prevention. The primary aims of iStoppFalls are to assess the feasi...

  1. ETHIOPIAN WITNESS PROTECTION SYSTEM: COMPARATIVE ...

    African Journals Online (AJOL)

    -africas- criminal-justice-systems . 4 Dr. YvonDandurand and Kirstin Farr N.P, A Review of Selected Witness Protection. Programs: Canada Law Enforcement and Policy Branch Public Safety Canada Research.

  2. Woven Thermal Protection System (WTPS)

    Data.gov (United States)

    National Aeronautics and Space Administration — Woven Thermal Protection System (TPS) is a 14-month technology development project to prove the feasibility of woven material as a game changing approach for future...

  3. Central nervous system medications and falls risk in men aged 60-75 years

    DEFF Research Database (Denmark)

    Masud, Tahir; Frost, Morten; Ryg, Jesper

    2013-01-01

    Introduction: drugs acting on the central nervous system (CNS) increase falls risk. Most data on CNS drugs and falls are in women/mixed-sex populations. This study assessed the relationship between CNS drugs and falls in men aged 60-75 years.......Introduction: drugs acting on the central nervous system (CNS) increase falls risk. Most data on CNS drugs and falls are in women/mixed-sex populations. This study assessed the relationship between CNS drugs and falls in men aged 60-75 years....

  4. Fan blade protection system

    Science.gov (United States)

    Hermans, Thomas C. (Inventor); Wakeman, Thomas G. (Inventor); Hauser, Ambrose A. (Inventor)

    1993-01-01

    In one type of aircraft propulsion system, propeller blades are mounted on a ring which surrounds a turbine. An annular space exists between the turbine and the ring. If a propeller blade should break free, the unbalanced centrifugal load tends to deform the ring. The invention reduces the deformation, as by locating spacers between the turbine and the ring.

  5. Automation warning system against driver falling asleep in-traffic

    Directory of Open Access Journals (Sweden)

    Dymov I. S.

    2017-12-01

    Full Text Available The paper is devoted to the development of a new automation recognition and warning system against driver falling asleep in-traffic. The issue of the physical condition control of professional drivers on the voyage has been considered both on the part of efficiency and quality of its determination, and in terms of improving overall road safety. The existing and widely used devices for determining the transition to the stage of sleep of drivers being in-traffic have been analyzed. Their advantages and disadvantages have been detected. It has been established that the main negative factor preventing the mass introduction of pre-existing warning systems is the need to wear one or another monitoring device before starting the movement. Carried out project research work has proposed a complex monitoring of the physical and physiological condition of driving person as a new warning method against falling asleep in-traffic. The proposed variations of algorithmic implementations can be used in long-distance trucks and passenger vehicles. Two different versions of the automatic control status of the driver physical condition have been considered. The first approach has proposed the use of sensors of the biometric parameters of body, pulsus, body temperature, and hands on wheel pressure sensors. The second one has proposed using the tracking cameras. Both for the first and second versions of the automation system a toolset of control devices is being installed inside the vehicle and have no physical, so irritating action on the driver. Software approach for the false operation rejection of the devices has been developed. The paper considers the flow diagrams of the automatic systems and logical structure of analysis and decision-making. The set of impacts intended for driver's awakening has been proposed. The conclusion about the engineering perspectives of the proposed approach of projected automation systems has been made.

  6. Home Camera-Based Fall Detection System for the Elderly

    Directory of Open Access Journals (Sweden)

    Koldo de Miguel

    2017-12-01

    Full Text Available Falls are the leading cause of injury and death in elderly individuals. Unfortunately, fall detectors are typically based on wearable devices, and the elderly often forget to wear them. In addition, fall detectors based on artificial vision are not yet available on the market. In this paper, we present a new low-cost fall detector for smart homes based on artificial vision algorithms. Our detector combines several algorithms (background subtraction, Kalman filtering and optical flow as input to a machine learning algorithm with high detection accuracy. Tests conducted on over 50 different fall videos have shown a detection ratio of greater than 96%.

  7. Home Camera-Based Fall Detection System for the Elderly.

    Science.gov (United States)

    de Miguel, Koldo; Brunete, Alberto; Hernando, Miguel; Gambao, Ernesto

    2017-12-09

    Falls are the leading cause of injury and death in elderly individuals. Unfortunately, fall detectors are typically based on wearable devices, and the elderly often forget to wear them. In addition, fall detectors based on artificial vision are not yet available on the market. In this paper, we present a new low-cost fall detector for smart homes based on artificial vision algorithms. Our detector combines several algorithms (background subtraction, Kalman filtering and optical flow) as input to a machine learning algorithm with high detection accuracy. Tests conducted on over 50 different fall videos have shown a detection ratio of greater than 96%.

  8. Power system protection 3 application

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  9. Business model for sensor-based fall recognition systems.

    Science.gov (United States)

    Fachinger, Uwe; Schöpke, Birte

    2014-01-01

    AAL systems require, in addition to sophisticated and reliable technology, adequate business models for their launch and sustainable establishment. This paper presents the basic features of alternative business models for a sensor-based fall recognition system which was developed within the context of the "Lower Saxony Research Network Design of Environments for Ageing" (GAL). The models were developed parallel to the R&D process with successive adaptation and concretization. An overview of the basic features (i.e. nine partial models) of the business model is given and the mutual exclusive alternatives for each partial model are presented. The partial models are interconnected and the combinations of compatible alternatives lead to consistent alternative business models. However, in the current state, only initial concepts of alternative business models can be deduced. The next step will be to gather additional information to work out more detailed models.

  10. Step Training System: an ICT solution to measure and reduce fall risk in older adults.

    Science.gov (United States)

    Smith, Stuart T; Davies, Thomas A; Lennox, Jamie

    2013-01-01

    Falls in older adults are a significant public heath issue with over 1/3 community-dwelling people aged 65 and over falling each year, many of them multiple times. We have developed and evaluated a set top box PC solution for delivering both fall risk assessment and fall risk reduction programs into the home. Preliminary field tests show that older adults engage with the system but that barriers to maintained use of the system do exist.

  11. Automated Technology for In-home Fall Risk Assessment and Detection Sensor System

    OpenAIRE

    Rantz, Marilyn J.; Skubic, Marjorie; Abbott, Carmen; Galambos, Colleen; Pak, Youngju; Ho, Dominic K.C.; Stone, Erik E.; Rui, Liyang; Back, Jessica; Miller, Steven J.

    2013-01-01

    Falls are a major problem for older adults. A continuous, unobtrusive, environmentally mounted in-home monitoring system that automatically detects when falls have occurred or when the risk of falling is increasing could alert health care providers and family members so they could intervene to improve physical function or mange illnesses that are precipitating falls. Researchers at the University of Missouri (MU)Center for Eldercare and Rehabilitation Technology are testing such sensor system...

  12. Sandia Laboratories plutonium protection system

    International Nuclear Information System (INIS)

    Bernard, E.A.; Miyoshi, D.S.; Gutierrez, F.D.

    1977-01-01

    Sandia Laboratories is developing an improved plutonium protection system (PPS) to demonstrate new concepts for enhancing special nuclear materials safeguards. PPS concepts include separation of functions, real-time item accountability and improved means for control of materials, activities and personnel access. Physical barriers and a secure communications network are designed into the system to offer greater protection against sabotage, diversion and theft attempts. Prototype systems are being constructed at Hanford, Washington and Albuquerque, New Mexico and will be subjected to a comprehensive testing and evaluation program

  13. Modern thyratron crowbar protection systems

    International Nuclear Information System (INIS)

    Judd, D.A.; Kettle, L.J.; Menown, H.; Newton, B.P.; Nicholls, N.S.; Sheldrake, R.

    1992-01-01

    Two thyratron crowbar systems for high-power klystrons used in linear accelerators are described. The first, contained in an oil filled tank, is a complete system to protect a klystron powered from a 100-kV, 20-A d.c. supply. In the second system a CX1722 glass thyratron, operating in air, has been retrofitted to a test equipment, in place of a spark gap, to protect an Inductive Output Tube (IOT). An important parameter in the choice of the crowbar thyratron is the total coulombs to be switched. Measurements of these follow-on currents are presented. (R.P.) 4 refs.; 10 figs

  14. Effects of falling weight impact on industrial safety helmets used in conjunction with eye and face protection devices.

    Science.gov (United States)

    Baszczyński, Krzysztof

    2018-06-01

    Industrial workplaces pose concurrent hazards to the upper part of the head and the eyes. Under the circumstances, workers may use protective helmets in conjunction with protective goggles or spectacles. In order to assess the compatibility of this equipment, a method and a test stand for evaluating the behavior of safety helmets and protective goggles/spectacles upon the impact of a falling weight were designed. The results of tests concerning the displacement and deformation of helmets and spectacles/goggles, the forces acting on the helmets, as well as the forces exerted by the spectacles/goggles on the headform upon falling weight impact are presented. The results revealed the ways in which the tested equipment interacted with each other. The influence of equipment construction on the test results was analyzed and inferences concerning the safety of the studied protective devices were made. Some general construction guidelines were formulated for the compatibility of the equipment.

  15. Standpipe systems for fire protection

    CERN Document Server

    Isman, Kenneth E

    2017-01-01

    This important new manual goes beyond the published NFPA standards on installation of standpipe systems to include the rules in the International Building Code, municipal fire codes, the National Fire Code of Canada, and information on inspection, testing, and maintenance of standpipe systems. Also covered are the interactions between standpipe and sprinkler systems, since these important fire protection systems are so frequently installed together. Illustrated with design examples and practical applications to reinforce the learning experience, this is the go-to reference for engineers, architects, design technicians, building inspectors, fire inspectors, and anyone that inspects, tests or maintains fire protection systems. Fire marshals and plan review authorities that have the responsibility for reviewing and accepting plans and hydraulic calculations for standpipe systems are also an important audience, as are firefighters who actually use standpipe systems. As a member of the committees responsible for s...

  16. The Diamond machine protection system

    International Nuclear Information System (INIS)

    Heron, M.T.; Lay, S.; Chernousko, Y.; Hamadyk, P.; Rotolo, N.

    2012-01-01

    The Diamond Light Source Machine Protection System (MPS) manages the hazards from high power photon beams and other hazards to ensure equipment protection on the booster synchrotron and storage ring. The system has a shutdown requirement, on a beam mis-steer of under 1 msec and has to manage in excess of a thousand interlocks. This is realised using a combination of bespoke hardware and programmable logic controllers. The MPS monitors a large number of interlock signals from diagnostics instrumentation, vacuum instrumentation, photon front ends and plant monitoring subsystems. Based on logic it can then remove the source of the energy to ensure protection of equipment. Depending on requirements, interlocks are managed on a Local or a Global basis. The Global system is structured as two layers, and supports fast- and slow-response-time interlock requirements. A Global MPS module takes the interlock permits for a given interlock circuit from each of the cells of the accelerator, and, subject to all interlocks being good, produces a permit to operate the source of energy: the RF amplifier for vessel protection and the PSU for magnet protection. The Local MPS module takes fast Interlock inputs from one cell of the Storage Ring or one quadrant of the Booster. Fast interlocks are those that must drop the beam in under 400 μsec (the maximum speed of the interlock) in the event of failure. EPIC provides the user interface to the MPS system

  17. Fall Prediction and Prevention Systems: Recent Trends, Challenges, and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Ramesh Rajagopalan

    2017-11-01

    Full Text Available Fall prediction is a multifaceted problem that involves complex interactions between physiological, behavioral, and environmental factors. Existing fall detection and prediction systems mainly focus on physiological factors such as gait, vision, and cognition, and do not address the multifactorial nature of falls. In addition, these systems lack efficient user interfaces and feedback for preventing future falls. Recent advances in internet of things (IoT and mobile technologies offer ample opportunities for integrating contextual information about patient behavior and environment along with physiological health data for predicting falls. This article reviews the state-of-the-art in fall detection and prediction systems. It also describes the challenges, limitations, and future directions in the design and implementation of effective fall prediction and prevention systems.

  18. Controls and Machine Protection Systems

    CERN Document Server

    Carrone, E.

    2016-01-01

    Machine protection, as part of accelerator control systems, can be managed with a 'functional safety' approach, which takes into account product life cycle, processes, quality, industrial standards and cybersafety. This paper will discuss strategies to manage such complexity and the related risks, with particular attention to fail-safe design and safety integrity levels, software and hardware standards, testing, and verification philosophy. It will also discuss an implementation of a machine protection system at the SLAC National Accelerator Laboratory's Linac Coherent Light Source (LCLS).

  19. DEVELOPMENT OF WEARABLE HUMAN FALL DETECTION SYSTEM USING MULTILAYER PERCEPTRON NEURAL NETWORK

    Directory of Open Access Journals (Sweden)

    Hamideh Kerdegari

    2013-02-01

    Full Text Available This paper presents an accurate wearable fall detection system which can identify the occurrence of falls among elderly population. A waist worn tri-axial accelerometer was used to capture the movement signals of human body. A set of laboratory-based falls and activities of daily living (ADL were performed by volunteers with different physical characteristics. The collected acceleration patterns were classified precisely to fall and ADL using multilayer perceptron (MLP neural network. This work was resulted to a high accuracy wearable fall-detection system with the accuracy of 91.6%.

  20. Power system protection 2 systems and methods

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  1. The LHC quench protection system

    CERN Multimedia

    2009-01-01

    The new quench protection system (QPS) has the crucial roles of providing an early warning for any part of the superconducting coils and busbars that develop high resistance, as well as triggering the switch-off of the machine. Over 2000 new detectors will be installed around the LHC to make sure every busbar segment between magnets is monitored and protected. One of the major consolidation activities for the LHC is the addition of two new detectors to the quench protection system. A magnet quench occurs when part of the superconducting cable becomes normally-conducting. When the protection system detects an increased resistance the huge amount of energy stored in the magnet chains is safely extracted and ‘dumped’ into specially designed resistors. In the case of the main dipole chain, the stored energy in a single LHC sector is roughly the same as the kinetic energy of a passenger jet at cruising speed. The first new detector is designed to monitor the superconducting...

  2. Design a Learning-Oriented Fall Event Reporting System Based on Kirkpatrick Model.

    Science.gov (United States)

    Zhou, Sicheng; Kang, Hong; Gong, Yang

    2017-01-01

    Patient fall has been a severe problem in healthcare facilities around the world due to its prevalence and cost. Routine fall prevention training programs are not as effective as expected. Using event reporting systems is the trend for reducing patient safety events such as falls, although some limitations of the systems exist at current stage. We summarized these limitations through literature review, and developed an improved web-based fall event reporting system. The Kirkpatrick model, widely used in the business area for training program evaluation, has been integrated during the design of our system. Different from traditional event reporting systems that only collect and store the reports, our system automatically annotates and analyzes the reported events, and provides users with timely knowledge support specific to the reported event. The paper illustrates the design of our system and how its features are intended to reduce patient falls by learning from previous errors.

  3. 30 CFR 77.403 - Mobile equipment; falling object protective structures (FOPS).

    Science.gov (United States)

    2010-07-01

    ... AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.403 Mobile equipment; falling... which meet the requirements of the Society of Automotive Engineers (SAE) Standard J 231 shall be...

  4. Autonomous systems for plant protection

    DEFF Research Database (Denmark)

    Griepentrog, Hans W.; Ruckelhausen, Arno; Jørgensen, Rasmus N.

    2010-01-01

    of autonomous operations related to crop protection probably commercially available in the near future. Scouting and monitoring together with the efficient application of chemicals or mechanical treatments are operations which can be successful automated. Drawbacks are that current systems are lacking robust......Advances in automation are demanded by the market mainly as a response to high labor costs. Robotic outdoor systems are ready to allow not only economically viable operations but also increased efficiency in agriculture, horticulture and forestry. The aim of this chapter is to give examples...

  5. An Unobtrusive Fall Detection and Alerting System Based on Kalman Filter and Bayes Network Classifier.

    Science.gov (United States)

    He, Jian; Bai, Shuang; Wang, Xiaoyi

    2017-06-16

    Falls are one of the main health risks among the elderly. A fall detection system based on inertial sensors can automatically detect fall event and alert a caregiver for immediate assistance, so as to reduce injuries causing by falls. Nevertheless, most inertial sensor-based fall detection technologies have focused on the accuracy of detection while neglecting quantization noise caused by inertial sensor. In this paper, an activity model based on tri-axial acceleration and gyroscope is proposed, and the difference between activities of daily living (ADLs) and falls is analyzed. Meanwhile, a Kalman filter is proposed to preprocess the raw data so as to reduce noise. A sliding window and Bayes network classifier are introduced to develop a wearable fall detection system, which is composed of a wearable motion sensor and a smart phone. The experiment shows that the proposed system distinguishes simulated falls from ADLs with a high accuracy of 95.67%, while sensitivity and specificity are 99.0% and 95.0%, respectively. Furthermore, the smart phone can issue an alarm to caregivers so as to provide timely and accurate help for the elderly, as soon as the system detects a fall.

  6. The primary protection system software

    International Nuclear Information System (INIS)

    Tooley, P.A.

    1992-01-01

    This paper continues the detailed description of the Primary Protection System for Sizewell-B by providing an overview of design and implementation of the software, including the features of the design process which ensure that quality is delivered by the contractor. The Nuclear Electric software assessment activities are also described. The argument for the excellence of the software is made on the basis of a quality product delivered by the equipment supplier's design process, and the confirmation of this provided by the Nuclear Electric assessment process, which is as searching and complete an examination as is reasonably practicable to achieve. (author)

  7. Vision-based fall detection system for improving safety of elderly people

    KAUST Repository

    Harrou, Fouzi

    2017-12-06

    Recognition of human movements is very useful for several applications, such as smart rooms, interactive virtual reality systems, human detection and environment modeling. The objective of this work focuses on the detection and classification of falls based on variations in human silhouette shape, a key challenge in computer vision. Falls are a major health concern, specifically for the elderly. In this study, the detection is achieved with a multivariate exponentially weighted moving average (MEWMA) monitoring scheme, which is effective in detecting falls because it is sensitive to small changes. Unfortunately, an MEWMA statistic fails to differentiate real falls from some fall-like gestures. To remedy this limitation, a classification stage based on a support vector machine (SVM) is applied on detected sequences. To validate this methodology, two fall detection datasets have been tested: the University of Rzeszow fall detection dataset (URFD) and the fall detection dataset (FDD). The results of the MEWMA-based SVM are compared with three other classifiers: neural network (NN), naïve Bayes and K-nearest neighbor (KNN). These results show the capability of the developed strategy to distinguish fall events, suggesting that it can raise an early alert in the fall incidents.

  8. Lightning Protection and Detection System

    Science.gov (United States)

    Dudley, Kenneth L. (Inventor); Szatkowski, George N. (Inventor); Woodard, Marie (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor); Wang, Chuantong (Inventor); Mielnik, John J. (Inventor); Koppen, Sandra V. (Inventor); Smith, Laura J. (Inventor)

    2017-01-01

    A lightning protection and detection system includes a non-conductive substrate material of an apparatus; a sensor formed of a conductive material and deposited on the non-conductive substrate material of the apparatus. The sensor includes a conductive trace formed in a continuous spiral winding starting at a first end at a center region of the sensor and ending at a second end at an outer corner region of the sensor, the first and second ends being open and unconnected. An electrical measurement system is in communication with the sensor and receives a resonant response from the sensor, to perform detection, in real-time, of lightning strike occurrences and damage therefrom to the sensor and the non-conductive substrate material.

  9. Automated In-Home Fall Risk Assessment and Detection Sensor System for Elders.

    Science.gov (United States)

    Rantz, Marilyn; Skubic, Marjorie; Abbott, Carmen; Galambos, Colleen; Popescu, Mihail; Keller, James; Stone, Erik; Back, Jessie; Miller, Steven J; Petroski, Gregory F

    2015-06-01

    Falls are a major problem for the elderly people leading to injury, disability, and even death. An unobtrusive, in-home sensor system that continuously monitors older adults for fall risk and detects falls could revolutionize fall prevention and care. A fall risk and detection system was developed and installed in the apartments of 19 older adults at a senior living facility. The system includes pulse-Doppler radar, a Microsoft Kinect, and 2 web cameras. To collect data for comparison with sensor data and for algorithm development, stunt actors performed falls in participants' apartments each month for 2 years and participants completed fall risk assessments (FRAs) using clinically valid, standardized instruments. The FRAs were scored by clinicians and recorded by the sensing modalities. Participants' gait parameters were measured as they walked on a GAITRite mat. These data were used as ground truth, objective data to use in algorithm development and to compare with radar and Kinect generated variables. All FRAs are highly correlated (p falls are being sent to clinicians providing faster responses to urgent situations. The in-home FRA and detection system has the potential to help older adults remain independent, maintain functional ability, and live at home longer. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Wind turbine with lightning protection system

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a wind turbine comprising a lightning protection system comprising a waveguide interconnecting a communication device and a signal-carrying structure. In other aspects, the present invention relates to the use of a waveguide in a lightning protection system...... of a wind turbine, a power splitter and its use in a lightning protection system of a wind turbine....

  11. Thermal protection system ablation sensor

    Science.gov (United States)

    Gorbunov, Sergey (Inventor); Martinez, Edward R. (Inventor); Scott, James B. (Inventor); Oishi, Tomomi (Inventor); Fu, Johnny (Inventor); Mach, Joseph G. (Inventor); Santos, Jose B. (Inventor)

    2011-01-01

    An isotherm sensor tracks space vehicle temperatures by a thermal protection system (TPS) material during vehicle re-entry as a function of time, and surface recession through calibration, calculation, analysis and exposed surface modeling. Sensor design includes: two resistive conductors, wound around a tube, with a first end of each conductor connected to a constant current source, and second ends electrically insulated from each other by a selected material that becomes an electrically conductive char at higher temperatures to thereby complete an electrical circuit. The sensor conductors become shorter as ablation proceeds and reduced resistance in the completed electrical circuit (proportional to conductor length) is continually monitored, using measured end-to-end voltage change or current in the circuit. Thermocouple and/or piezoelectric measurements provide consistency checks on local temperatures.

  12. Automating occupational protection records systems

    International Nuclear Information System (INIS)

    Lyon, M.; Martin, J.B.

    1991-10-01

    Occupational protection records have traditionally been generated by field and laboratory personnel, assembled into files in the safety office, and eventually stored in a warehouse or other facility. Until recently, these records have been primarily paper copies, often handwritten. Sometimes, the paper is microfilmed for storage. However, electronic records are beginning to replace these traditional methods. The purpose of this paper is to provide guidance for making the transition to automated record keeping and retrieval using modern computer equipment. This paper describes the types of records most readily converted to electronic record keeping and a methodology for implementing an automated record system. The process of conversion is based on a requirements analysis to assess program needs and a high level of user involvement during the development. The importance of indexing the hard copy records for easy retrieval is also discussed. The concept of linkage between related records and its importance relative to reporting, research, and litigation will be addressed. 2 figs

  13. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system

  14. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  15. Distributed radiation protection console system

    International Nuclear Information System (INIS)

    Chhokra, R.S.; Deshpande, V.K.; Mishra, H.; Rajeev, K.P.; Thakur, Bipla B.; Munj, Niket

    2004-01-01

    Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area either from the CRPC or will get to know the same directly from the installed only after entering the area. This shortcoming can lead to avoidable delays in attending to the work or to unwanted exposure. The authors have designed and developed a system called Distributed Radiation Protection Console (DRPC) to overcome this shortcoming. A DRPC is a console which is located outside the entrance of a given area and displays the radiation status of the area. It presents to health physicist and the plant operators a graphic over-view of the radiation and air activity levels in the particular area of the plant. It also provides audio visual annunciation of the alarm status. Each radioactive area in a nuclear facility will have its own DRPC, which will receive as its inputs the analog and digital signals from radiation monitoring instruments installed in the area and would not only show those readings on its video graphic screen but will also provide warning messages and instructions to the personnel entering the active areas. The various DRPCs can be integrated into a Local Area Network, where the

  16. Evaluation of the android-based fall detection system with physiological data monitoring.

    Science.gov (United States)

    Koshmak, Gregory A; Linden, Maria; Loutfi, Amy

    2013-01-01

    Aging population is considered to be major problem in modern healthcare. At the same time, fall incidents often occur among elderly and cause serious injuries affecting their independent living. This paper proposes a framework which uses mobile phone technology together with physiological data monitoring in order to detect falls. The system carries out collecting, storing and processing of acceleration data with further alarm generating and transferring all the measurements to remote caregiver. To perform evaluation, an experimental setup involving novice ice-skaters were carried out to obtain realistic fall data and examine the effects of falling on physiological parameters. A fall detection algorithm has been designed therefore to cope with large variations of movement in the torso. The online algorithm operating showed performance results of 90% specificity, 100% sensitivity and 94% accuracy.

  17. Recent Technology of the Protection System

    Science.gov (United States)

    Nagasawa, Takashi

    The protection relay changed from electromechanical or analog static type to digital type using the progress of microprocessor against the growth of power network. The digital relay improved protective performance and reliability based on establishment of various protection schemes and the embedded automatic supervising function using the development of the digital technique. Additionally, the recent protection system technique enable to make the configration and operation of power system efficient. Multi-terminal transmission lines can be realized by use of PCM current differential relay. The out-of-step protection, the voltage stability control and the over load failure extension protection can increase transmission capacity. In future, it will need to develop the protection system for the distributed power generation and decrease the cost of protection systems against the progress of deregulation.

  18. Reactor protection and shut-down system

    International Nuclear Information System (INIS)

    Klar

    1980-01-01

    The reactor protection system being a part of the reactor safety system. The requirements on the reactor protection system are: high safety with regard to signal processing, high availability, self-reporting of faults etc. The functional sections of the reactor protection system are the analog section, the logic section and the generating of output signals. Description of the operation characteristics and of the extension of function. (orig.)

  19. Passenger vehicle driver cell phone use : results from the fall 2000 National Occupant Protection Use Survey

    Science.gov (United States)

    2001-07-01

    The National Highway Traffic Safety Administration's National Occupant Protection Use Survey (NOPUS) expanded its data collection protocols during October and November 2000 to obtain national estimates of driver cell phone use. The results of NOPUS f...

  20. Falling short of protection: Peru’s new migration scheme for Venezuelans

    Directory of Open Access Journals (Sweden)

    Nicolas Parent

    2017-10-01

    Full Text Available Peru’s introduction of a new work and study permit for Venezuelans fleeing violence in their country is to be applauded – but it provides only a limited, temporary form of protection.

  1. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  2. ICT-based system to predict and prevent falls (iStoppFalls): study protocol for an international multicenter randomized controlled trial.

    Science.gov (United States)

    Gschwind, Yves J; Eichberg, Sabine; Marston, Hannah R; Ejupi, Andreas; Rosario, Helios de; Kroll, Michael; Drobics, Mario; Annegarn, Janneke; Wieching, Rainer; Lord, Stephen R; Aal, Konstantin; Delbaere, Kim

    2014-08-20

    Falls are very common, especially in adults aged 65 years and older. Within the current international European Commission's Seventh Framework Program (FP7) project 'iStoppFalls' an Information and Communication Technology (ICT) based system has been developed to regularly assess a person's risk of falling in their own home and to deliver an individual and tailored home-based exercise and education program for fall prevention. The primary aims of iStoppFalls are to assess the feasibility and acceptability of the intervention program, and its effectiveness to improve balance, muscle strength and quality of life in older people. This international, multicenter study is designed as a single-blinded, two-group randomized controlled trial. A total of 160 community-dwelling older people aged 65 years and older will be recruited in Germany (n = 60), Spain (n = 40), and Australia (n = 60) between November 2013 and May 2014. Participants in the intervention group will conduct a 16-week exercise program using the iStoppFalls system through their television set at home. Participants are encouraged to exercise for a total duration of 180 minutes per week. The training program consists of a variety of balance and strength exercises in the form of video games using exergame technology. Educational material about a healthy lifestyle will be provided to each participant. Final reassessments will be conducted after 16 weeks. The assessments include physical and cognitive tests as well as questionnaires assessing health, fear of falling, quality of life and psychosocial determinants. Falls will be followed up for six months by monthly falls calendars. We hypothesize that the regular use of this newly developed ICT-based system for fall prevention at home is feasible for older people. By using the iStoppFalls sensor-based exercise program, older people are expected to improve in balance and strength outcomes. In addition, the exercise training may have a positive impact on quality of

  3. RIVER PROTECTION PROJECT SYSTEM PLAN

    International Nuclear Information System (INIS)

    CERTA PJ

    2008-01-01

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, the ORP is responsible for the retrieval, treatment, and disposal of the approximately 57 million gallons of radioactive waste contained in the Hanford Site waste tanks and closure of all the tanks and associated facilities. The previous revision of the System Plan was issued in September 2003. ORP has approved a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. The ORP has established contracts to implement this strategy to establish a basic capability to complete the overall mission. The current strategy for completion of the mission uses a number of interrelated activities. The ORP will reduce risk to the environment posed by tank wastes by: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) for treatment and disposal; (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) and about half of the low-activity waste (LAW) contained in the tank farms, and maximizing its capability and capacity; (3) Developing and deploying supplemental treatment capability or a second WTP LAW Facility that can safely treat about half of the LAW contained in the tank farms; (4) Developing and deploying treatment and packaging capability for transuranic (TRU) tank waste for shipment to and disposal at the Waste Isolation Pilot Plant (WIPP); (5) Deploying interim storage capacity for the immobilized HLW and shipping that waste to Yucca Mountain for disposal; (6) Operating the Integrated Disposal Facility for the disposal of immobilized LAW, along with the associated secondary waste, (7) Closing the SST and DST tank farms, ancillary facilities, and al1 waste

  4. RIVER PROTECTION PROJECT SYSTEM PLAN

    Energy Technology Data Exchange (ETDEWEB)

    CERTA PJ

    2008-07-10

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, the ORP is responsible for the retrieval, treatment, and disposal of the approximately 57 million gallons of radioactive waste contained in the Hanford Site waste tanks and closure of all the tanks and associated facilities. The previous revision of the System Plan was issued in September 2003. ORP has approved a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. The ORP has established contracts to implement this strategy to establish a basic capability to complete the overall mission. The current strategy for completion of the mission uses a number of interrelated activities. The ORP will reduce risk to the environment posed by tank wastes by: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) for treatment and disposal; (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) and about half of the low-activity waste (LAW) contained in the tank farms, and maximizing its capability and capacity; (3) Developing and deploying supplemental treatment capability or a second WTP LAW Facility that can safely treat about half of the LAW contained in the tank farms; (4) Developing and deploying treatment and packaging capability for transuranic (TRU) tank waste for shipment to and disposal at the Waste Isolation Pilot Plant (WIPP); (5) Deploying interim storage capacity for the immobilized HLW and shipping that waste to Yucca Mountain for disposal; (6) Operating the Integrated Disposal Facility for the disposal of immobilized LAW, along with the associated secondary waste, (7) Closing the SST and DST tank farms, ancillary facilities, and al1 waste

  5. Promoting an Integral Social Protection System

    OpenAIRE

    World Bank

    2013-01-01

    This note reviews the challenges in Mexico s social protection system and possible options to achieve an integral and effective system that is more than the sum of its parts. Mexico s social protection system includes contributory social security schemes, social assistance programs, and labor market programs. The contributory social security schemes offer pensions and health insurance to f...

  6. RIVER PROTECTION PROJECT SYSTEM PLAN

    Energy Technology Data Exchange (ETDEWEB)

    CERTA PJ; KIRKBRIDE RA; HOHL TM; EMPEY PA; WELLS MN

    2009-09-15

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, ORP is responsible for the retrieval, treatment, and disposal of approximately 57 million gallons 1 of radioactive waste contained in the Hanford Site waste tanks and closure2 of all the tanks and associated facilities. The previous revision of the System Plan was issued in May 2008. ORP has made a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. ORP has contracts in place to implement the strategy for completion of the mission and establish the capability to complete the overall mission. The current strategl involves a number of interrelated activities. ORP will reduce risk to the environment posed by tank wastes by the following: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) and delivering the waste to the Waste Treatment and Immobilization Plant (WTP). (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) fraction contained in the tank farms. About one-third of the low-activity waste (LAW) fraction separated from the HLW fraction in the WTP will be immobilized in the WTP LAW Vitrification Facility. (3) Developing and deploying supplemental treatment capability assumed to be a second LAW vitrification facility that can safely treat about two-thirds of the LAW contained in the tank farms. (4) Developing and deploying supplemental pretreatment capability currently assumed to be an Aluminum Removal Facility (ARF) using a lithium hydrotalcite process to mitigate sodium management issues. (5) Developing and deploying treatment and packaging capability for contact-handled transuranic (CH-TRU) tank waste for possible shipment to and

  7. RIVER PROTECTION PROJECT SYSTEM PLAN

    International Nuclear Information System (INIS)

    Certa, P.J.; Kirkbride, R.A.; Hohl, T.M.; Empey, P.A.; Wells, M.N.

    2009-01-01

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, ORP is responsible for the retrieval, treatment, and disposal of approximately 57 million gallons 1 of radioactive waste contained in the Hanford Site waste tanks and closure2 of all the tanks and associated facilities. The previous revision of the System Plan was issued in May 2008. ORP has made a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. ORP has contracts in place to implement the strategy for completion of the mission and establish the capability to complete the overall mission. The current strategl involves a number of interrelated activities. ORP will reduce risk to the environment posed by tank wastes by the following: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) and delivering the waste to the Waste Treatment and Immobilization Plant (WTP). (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) fraction contained in the tank farms. About one-third of the low-activity waste (LAW) fraction separated from the HLW fraction in the WTP will be immobilized in the WTP LAW Vitrification Facility. (3) Developing and deploying supplemental treatment capability assumed to be a second LAW vitrification facility that can safely treat about two-thirds of the LAW contained in the tank farms. (4) Developing and deploying supplemental pretreatment capability currently assumed to be an Aluminum Removal Facility (ARF) using a lithium hydrotalcite process to mitigate sodium management issues. (5) Developing and deploying treatment and packaging capability for contact-handled transuranic (CH-TRU) tank waste for possible shipment to and disposal

  8. Real-time monitoring system for elderly people in detecting falling movement using accelerometer and gyroscope

    Science.gov (United States)

    Siregar, B.; Andayani, U.; Bahri, R. P.; Seniman; Fahmi, F.

    2018-03-01

    Most of the elderly people is experiencing a decrease in physical quality, especially the weakness in the legs. This will cause elderly easy to fall and can have a serious impact on their health if not getting help very quickly. It is, therefore, necessary to take immediate action against the falling cases experienced by the elderly. One such action is by developing supervision and detecting of falling movements in real-time, which is then the connection to a member of the family. In this research, we used Arduino Uno as a microcontroller, sensor accelerometer, and gyroscope that serves to measure falling movement of the elderly person and supported by GPS technology Ublox Neo 6M to provide information about coordinates. The result was the high accuracy of delivering notification data to server and accuracy of data delivery to family notification equal to 93,75%. The system successfully detects the direction of falling: forward, backward, left or right and able to distinguish between unintentional falling and conscious falling like a bow or prostrate position.

  9. ICT-based system to predict and prevent falls (iStoppFalls): results from an international multicenter randomized controlled trial.

    Science.gov (United States)

    Gschwind, Yves J; Eichberg, Sabine; Ejupi, Andreas; de Rosario, Helios; Kroll, Michael; Marston, Hannah R; Drobics, Mario; Annegarn, Janneke; Wieching, Rainer; Lord, Stephen R; Aal, Konstantin; Vaziri, Daryoush; Woodbury, Ashley; Fink, Dennis; Delbaere, Kim

    2015-01-01

    Falls and fall-related injuries are a serious public health issue. Exercise programs can effectively reduce fall risk in older people. The iStoppFalls project developed an Information and Communication Technology-based system to deliver an unsupervised exercise program in older people's homes. The primary aims of the iStoppFalls randomized controlled trial were to assess the feasibility (exercise adherence, acceptability and safety) of the intervention program and its effectiveness on common fall risk factors. A total of 153 community-dwelling people aged 65+ years took part in this international, multicentre, randomized controlled trial. Intervention group participants conducted the exercise program for 16 weeks, with a recommended duration of 120 min/week for balance exergames and 60 min/week for strength exercises. All intervention and control participants received educational material including advice on a healthy lifestyle and fall prevention. Assessments included physical and cognitive tests, and questionnaires for health, fear of falling, number of falls, quality of life and psychosocial outcomes. The median total exercise duration was 11.7 h (IQR = 22.0) over the 16-week intervention period. There were no adverse events. Physiological fall risk (Physiological Profile Assessment, PPA) reduced significantly more in the intervention group compared to the control group (F1,127 = 4.54, p = 0.035). There was a significant three-way interaction for fall risk assessed by the PPA between the high-adherence (>90 min/week; n = 18, 25.4 %), low-adherence (fall risk (p = 0.031), postural sway (p = 0.046), stepping reaction time (p = 0.041), executive functioning (p = 0.044), and quality of life (p for trend = 0.052). The iStoppFalls exercise program reduced physiological fall risk in the study sample. Additional subgroup analyses revealed that intervention participants with better adherence also improved in postural sway

  10. The protection effects of buildings in front of nuclear fall-out

    International Nuclear Information System (INIS)

    Mueck, K.; Lovranich, E.; Steger, F.

    1995-02-01

    In order to adopt appropriate countermeasures to protect the public in case of a wide-spread contamination after a severe reactor accident, a profound knowledge of the dose to be expected of the dose reduction to be expected if a specific countermeasure is adopted is required. Since external radiation contributes a major fraction of up to 80 % to the total dose, the interest is focussed on the reduction of external dose by staying indoors. For this purpose measurements of the dose reduction by external radiation were performed in 40 residential rooms in Vienna which were chosen according to their fraction of the Viennese building structure. They were performed by measurement of the reduction of the gamma-flux in the interior of buildings compared to the gamma-flux outside. Measurements were carried out by a HPGe-detector which was positioned 1 m above ground. The observed dose reduction factors amounted to 0.013 on the average (protection factor 78,7 '+-' 49,7), with the protection factors of the investigated building types ranging from 6,5 (single house in garden) to 122,9 (edicifices of the turn of the century). The observed protection factors do not include the dose reduction by dense arrangement of buildings in urban areas which has to be considered separately. The dose reduction due to different radionuclide mixtures after severe reactor accidents was also investigated. Factors similar to that observed for Cs-137 were found. The maximum deviations amounted only 12 % and therefore may be neglected in the consideration of protective measures. Additional measurements were performed with the same detector shielded by lead on all sides to determine the contribution of the interior contamination. A contribution of between < 10 % to 50 % to the external dose in the interior of buildings was observed. Measures to reduce the inner contamination in rooms (closing of windows and doors, cleaning upon entering the building interior) in case of an event are therefore

  11. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1975-10-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely-activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. A list of measures is given for assessing overall physical protection system performance. (auth)

  12. Using a laser measurement system for monitoring morphological changes on the Strug rock fall, Slovenia

    Directory of Open Access Journals (Sweden)

    M. Mikoš

    2005-01-01

    Full Text Available A medium-ranged high performance handheld reflectorless laser measurement system, was used for a morphological survey on the Strug rock fall in W Slovenia in the period from August 2003 to August 2004. The purpose was to evaluate its potential for monitoring ground surface changes in rock fall source areas and to help evaluating morphological changes by measuring distance from fixed points. In the area, 21 fixed geodetic points have been established. Altogether, seven measurement sets with more than 5500 points have been gathered in the rock fall area. Choosing a point cloud with a density of less than 1 point per 10m2 on a very rough rock fall surface failed to be a good solution. The changes on larger areas were shown by displacements of selected significantly large-sized rock blocks with a volume of several m3. Because only smaller changes were observed between the single field series, the rock fall surface generally remained unchanged. Local surface changes of the order of 1 m or more, were clearly shown by measurements in the selected referenced cross sections. The usage of these cross sections gave a possibility to evaluate volumetric changes on the surface. The laser measurement system provided a good replacement for the classical terrestrial geodetic survey equipment, especially when performing remote monitoring of morphological changes in rock fall hazard zones, however, the case is different when fixed points are to be measured precisely.

  13. Programmed system for nuclear power plant protection

    International Nuclear Information System (INIS)

    Jover, Pierre.

    1980-06-01

    The progress in the field of microprocessors and large scale integration circuits, have incited to introduce this new technologies into nuclear power plant protection system. The hardware and software design principles are briefly listed; then, a quad-redundant protection system for 1300 MWe PWR, developed in France is described [fr

  14. Technological Innovation in Grade Crossing Protective Systems

    Science.gov (United States)

    1971-06-01

    The constraints on innovative grade crossing protective systems are delineated and guidelines for development indicated. Inventory data has been arranged to permit an estimate of the classes of systems needed, the allowable costs, and contribution of...

  15. Aging assessment for active fire protection systems

    International Nuclear Information System (INIS)

    Ross, S.B.; Nowlen, S.P.; Tanaka, T.

    1995-06-01

    This study assessed the impact of aging on the performance and reliability of active fire protection systems including both fixed fire suppression and fixed fire detection systems. The experience base shows that most nuclear power plants have an aggressive maintenance and testing program and are finding degraded fire protection system components before a failure occurs. Also, from the data reviewed it is clear that the risk impact of fire protection system aging is low. However, it is assumed that a more aggressive maintenance and testing program involving preventive diagnostics may reduce the risk impact even further

  16. Outer skin protection of columbium Thermal Protection System (TPS) panels

    Science.gov (United States)

    Culp, J. D.

    1973-01-01

    A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.

  17. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  18. Testing Digital Electronic Protection Systems

    CERN Document Server

    Gabourin, S

    2011-01-01

    This paper outlines the core concepts and realisation of the Safe Machine Parameters Controller (SMPC) testbench, based on a VME crate and LabVIEW program. Its main goal is to ensure the correct function of the SMPC for the protection of the CERN accelerator complex. To achieve this, the tester has been built to replicate the machine environment and operation, in order to ensure that the chassis under test is completely exercised. The complexity of the task increases with the number of input combinations. This paper also outlines the benefits and weaknesses of developing a test suite independently of the hardware being tested, using the “V” approach.

  19. Overload protection device for pulsed electric systems

    International Nuclear Information System (INIS)

    Glushchenko, V.G.; Kurskov, I.A.; Semina, R.S.

    1976-01-01

    Results of pulsed electric system protection development from effective pulse current overload depending on pulse duration are described. An integrating circuit, charge resistance of which is connected in parallel with a stabilitron, is used in a protection diagram. Given were time responses of overload protection of an output lens of slow root particle extraction channel from synchrophasotron; the responses have been obtained by the experimental and calculation methods

  20. Clinical feasibility trial of a motion detection system for fall prevention in hospitalized older adult patients.

    Science.gov (United States)

    Ferrari, Marisa; Harrison, Barbara; Rawashdeh, Osamah; Hammond, Robert; Avery, Yvonne; Rawashdeh, Muawea; Sa'deh, Waseem; Maddens, Michael

    2012-01-01

    The purpose of this pilot study was to test the feasibility of a wireless 5-sensor, motion detection system (5S-MDS) with hospitalized older adults. Interventions to prevent hospital-based falls in older adults are important to reduce morbidity, mortality, and health care costs. Wearable motion sensors, which track and wirelessly transmit body movements, may identify human movement patterns that immediately precede falls, thus allowing early prevention. Descriptive feasibility study in which 5 hospitalized older adults were recruited to wear the 5S-MDS for 4 hours. Measurement included assessment of participant acceptance, skin integrity, and sensor accuracy. All 5 participants (mean age, 90.2 years) agreed that sensors were acceptable and skin integrity was maintained. The sensor data accurately reflected the patient movements. The 5S-MDS was feasible for 4 hours' use with hospitalized older adults. It has potential as an early warning system for falls. Copyright © 2012 Mosby, Inc. All rights reserved.

  1. Impact of Diabetic Complications on Balance and Falls: Contribution of the Vestibular System.

    Science.gov (United States)

    D'Silva, Linda J; Lin, James; Staecker, Hinrich; Whitney, Susan L; Kluding, Patricia M

    2016-03-01

    Diabetes causes many complications, including retinopathy and peripheral neuropathy, which are well understood as contributing to gait instability and falls. A less understood complication of diabetes is the effect on the vestibular system. The vestibular system contributes significantly to balance in static and dynamic conditions by providing spatially orienting information. It is noteworthy that diabetes has been reported to affect vestibular function in both animal and clinical studies. Pathophysiological changes in peripheral and central vestibular structures due to diabetes have been noted. Vestibular dysfunction is associated with impaired balance and a higher risk of falls. As the prevalence of diabetes increases, so does the potential for falls due to diabetic complications. The purpose of this perspective article is to present evidence on the pathophysiology of diabetes-related complications and their influence on balance and falls, with specific attention to emerging evidence of vestibular dysfunction due to diabetes. Understanding this relationship may be useful for screening (by physical therapists) for possible vestibular dysfunction in people with diabetes and for further developing and testing the efficacy of interventions to reduce falls in this population. © 2016 American Physical Therapy Association.

  2. Microsoft System Center Data Protection Manager 2012

    CERN Document Server

    Buchannan, Steve; Gomaa, Islam

    2013-01-01

    This book is a Packt tutorial, walking the administrator through the steps needed to create real solutions to the problems and tasks faced when ensuring that their data is protected. This book is for network administrators, system administrators, backup administrators, or IT consultants who are looking to expand their knowledge on how to utilize DPM to protect their organization's data.

  3. Systems and methods for photovoltaic string protection

    Energy Technology Data Exchange (ETDEWEB)

    Krein, Philip T.; Kim, Katherine A.; Pilawa-Podgurski, Robert C. N.

    2017-10-25

    A system and method includes a circuit for protecting a photovoltaic string. A bypass switch connects in parallel to the photovoltaic string and a hot spot protection switch connects in series with the photovoltaic string. A first control signal controls opening and closing of the bypass switch and a second control signal controls opening and closing of the hot spot protection switch. Upon detection of a hot spot condition the first control signal closes the bypass switch and after the bypass switch is closed the second control signal opens the hot spot protection switch.

  4. Relay protection coordination with generator capability curve, excitation system limiters and power system relay protections settings

    Directory of Open Access Journals (Sweden)

    Buha Danilo

    2016-01-01

    Full Text Available The relay protection settings performed in the largest thermal powerplant (TE "Nikola Tesla B" are reffered and explained in this paper. The first calculation step is related to the coordination of the maximum stator current limiter settings, the overcurrent protection with inverse characteristics settings and the permitted overload of the generator stator B1. In the second calculation step the settings of impedance generator protection are determined, and the methods and criteria according to which the calculations are done are described. Criteria used to provide the protection to fulfill the backup protection role in the event of malfunction of the main protection of the transmission system. are clarified. The calculation of all protection functions (32 functions of generator B1 were performed in the project "Coordination of relay protection blocks B1 and B2 with the system of excitation and power system protections -TENT B".

  5. Evolution of the radiation protection system; L'evolution du systeme de protection radiologique

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, R.H. [International Commission on Radiological Protection, Stockholm (Sweden); Schieber, C.; Cordoliani, Y.S. [Societe Francaise de Radioprotection, 92 - Fontenay aux Roses (France); Brechignac, F. [CEA Cadarache, Institut de Radioprotection et de Surete Nucleaire, Dept. de Protection de l' Environnement, 13 - Saint Paul Lez Durance (France)

    2003-07-01

    The evolution of the system of radiological protection: justification for new ICRP recommendations, thoughts of the SFRP work group about the evolution of the system of radiation protection proposed by the ICRP, protection of environment against ionizing radiations seen by the ICRP are the three parts of this chapter. (N.C.)

  6. Unsupervised machine-learning method for improving the performance of ambulatory fall-detection systems

    Directory of Open Access Journals (Sweden)

    Yuwono Mitchell

    2012-02-01

    Full Text Available Abstract Background Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environments, in part because impacts can be experienced as part of ordinary daily living activities. Method We used a waist-worn wireless tri-axial accelerometer combined with digital signal processing, clustering and neural network classifiers. The method includes the application of Discrete Wavelet Transform, Regrouping Particle Swarm Optimization, Gaussian Distribution of Clustered Knowledge and an ensemble of classifiers including a multilayer perceptron and Augmented Radial Basis Function (ARBF neural networks. Results Preliminary testing with 8 healthy individuals in a home environment yields 98.6% sensitivity to falls and 99.6% specificity for routine Activities of Daily Living (ADL data. Single ARB and MLP classifiers were compared with a combined classifier. The combined classifier offers the greatest sensitivity, with a slight reduction in specificity for routine ADL and an increased specificity for exercise activities. In preliminary tests, the approach achieves 100% sensitivity on in-group falls, 97.65% on out-group falls, 99.33% specificity on routine ADL, and 96.59% specificity on exercise ADL. Conclusion The pre-processing and feature-extraction steps appear to simplify the signal while successfully extracting the essential features that are required to characterize a fall. The results suggest this combination of classifiers can perform better than MLP alone. Preliminary testing suggests these methods may be useful for researchers who are attempting to improve the performance of ambulatory fall-detection systems.

  7. Embedded DSP-based telehealth radar system for remote in-door fall detection.

    Science.gov (United States)

    Garripoli, Carmine; Mercuri, Marco; Karsmakers, Peter; Jack Soh, Ping; Crupi, Giovanni; Vandenbosch, Guy A E; Pace, Calogero; Leroux, Paul; Schreurs, Dominique

    2015-01-01

    Telehealth systems and applications are extensively investigated nowadays to enhance the quality-of-care and, in particular, to detect emergency situations and to monitor the well-being of elderly people, allowing them to stay at home independently as long as possible. In this paper, an embedded telehealth system for continuous, automatic, and remote monitoring of real-time fall emergencies is presented and discussed. The system, consisting of a radar sensor and base station, represents a cost-effective and efficient healthcare solution. The implementation of the fall detection data processing technique, based on the least-square support vector machines, through a digital signal processor and the management of the communication between radar sensor and base station are detailed. Experimental tests, for a total of 65 mimicked fall incidents, recorded with 16 human subjects (14 men and two women) that have been monitored for 320 min, have been used to validate the proposed system under real circumstances. The subjects' weight is between 55 and 90 kg with heights between 1.65 and 1.82 m, while their age is between 25 and 39 years. The experimental results have shown a sensitivity to detect the fall events in real time of 100% without reporting false positives. The tests have been performed in an area where the radar's operation was not limited by practical situations, namely, signal power, coverage of the antennas, and presence of obstacles between the subject and the antennas.

  8. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1979-01-01

    An absorber element blow-out protection system for a nuclear reactor having a pressure vessel through which a coolant is circulated. The blow-out protection system includes devices which hydraulically couple groups of guide tubes in which the absorber elements move, the coupling devices limiting coolant lift flow rate to a level commensurate with the raising of individual absorber elements but insufficient to raise a plurality of absorber elements simultaneously

  9. Falling chains as variable-mass systems: theoretical model and experimental analysis

    International Nuclear Information System (INIS)

    De Sousa, Célia A; Costa, Pedro; Gordo, Paulo M

    2012-01-01

    In this paper, we revisit, theoretically and experimentally, the fall of a folded U-chain and of a pile-chain. The model calculation implies the division of the whole system into two subsystems of variable mass, allowing us to explore the role of tensional contact forces at the boundary of the subsystems. This justifies, for instance, that the folded U-chain falls faster than the acceleration due to the gravitational force. This result, which matches quite well with the experimental data independently of the type of chain, implies that the falling chain is well described by energy conservation. We verify that these conclusions are not observed for the pile-chain motion. (paper)

  10. A new smart fall-down detector for senior healthcare system using inertial microsensors.

    Science.gov (United States)

    Sui, Yongkun; Ahn, Chanmin; Ahn, Chong H

    2014-01-01

    A new smart fall-down detector for senior healthcare system using inertial microsensors and Wi-Fi technology has been designed, prototyped and characterized in this work. The detector can reduce the risk of severe injury or death caused by falling down with minimum false alarm rate. The different patterns of motion are sensed by a set of inertial sensors composed of a tri-axial accelerometer and a tri-axial gyroscope. The signals of motion are sampled and processed by a microcontroller with integrated algorithms. The smart algorithm integrated with machine learning can be customized according to different habits of different seniors to reduce false alarms. The fall-down signal is transmitted through Wi-Fi to the client via Internet.

  11. Numerical Estimation of Balanced and Falling States for Constrained Legged Systems

    Science.gov (United States)

    Mummolo, Carlotta; Mangialardi, Luigi; Kim, Joo H.

    2017-08-01

    Instability and risk of fall during standing and walking are common challenges for biped robots. While existing criteria from state-space dynamical systems approach or ground reference points are useful in some applications, complete system models and constraints have not been taken into account for prediction and indication of fall for general legged robots. In this study, a general numerical framework that estimates the balanced and falling states of legged systems is introduced. The overall approach is based on the integration of joint-space and Cartesian-space dynamics of a legged system model. The full-body constrained joint-space dynamics includes the contact forces and moments term due to current foot (or feet) support and another term due to altered contact configuration. According to the refined notions of balanced, falling, and fallen, the system parameters, physical constraints, and initial/final/boundary conditions for balancing are incorporated into constrained nonlinear optimization problems to solve for the velocity extrema (representing the maximum perturbation allowed to maintain balance without changing contacts) in the Cartesian space at each center-of-mass (COM) position within its workspace. The iterative algorithm constructs the stability boundary as a COM state-space partition between balanced and falling states. Inclusion in the resulting six-dimensional manifold is a necessary condition for a state of the given system to be balanced under the given contact configuration, while exclusion is a sufficient condition for falling. The framework is used to analyze the balance stability of example systems with various degrees of complexities. The manifold for a 1-degree-of-freedom (DOF) legged system is consistent with the experimental and simulation results in the existing studies for specific controller designs. The results for a 2-DOF system demonstrate the dependency of the COM state-space partition upon joint-space configuration (elbow-up vs

  12. Physical protection system design and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary`s capabilities, and range of adversary`s tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ``what to protect against whom.`` The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met.

  13. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ''what to protect against whom.'' The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met

  14. A flowchart system to improve fall data documentation in a long-term care institution: a pilot study.

    Science.gov (United States)

    Montero-Odasso, Manuel; Levinson, Paula; Gore, Brian; Epid, Dipl; Tremblay, Lucie; Bergman, Howard

    2007-06-01

    Falls are an important cause of morbidity and mortality in older people. In many long-term care (LTC) institutions, current practice focuses only on the injury consequences with a lack in the assessment of main risk factors, characteristics of the fall episode, and secondary prevention. To document current practice in our center and to determine whether implementation of a flowchart system may improve fall data documentation. A flowchart system with an ad hoc form was designed to advise on falls characteristics, post-fall risk factors identification, and appropriate referral. Educational sessions explaining the rationale for the flowchart system were given before the implementation of the system. An audit was conducted on incident report data in order to register the fall data documentation in our facility. The audit was repeated 2 months after implementation of the flowchart system. There were 107 incident reports audited before and after the implementation of the flowchart system. Seven observations were excluded. Average age of the participants with falls was 82.7 (SD: 3) and 53% of the participants had dementia. Comparisons between the first and second audit revealed significance differences in the history of previous falls (95% vs 35%, P flowchart system, documentation of risk factors and characteristics of fall episodes have improved significantly and referrals to a geriatrician for falls evaluation have significantly increased. The process of education and implementation of a flowchart system with an ad hoc form improved data documentation performed following a fall. This simple strategy could help the development of falls prevention program in the nursing home.

  15. Power system protection 1 principles and components

    CERN Document Server

    Association, Electricity Training

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  16. Distributed systems for protecting nuclear power stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-05-01

    The advantages of distributed control systems for the control of nuclear power stations are obviously of great interest. Some years ago, EPRI, (Electric Power Research Institute) showed that multiplexing the signals is technically feasible, that it enables the availability specifications to be met and costs to be reduced. Since then, many distributed control systems have been proposed by the manufacturers. This note offers some comments on the application of the distribution concept to protection systems -what should be distributed- and ends with a brief description of a protection system based on microprocessors for the pressurized power stations now being built in France [fr

  17. PCIe40 temperature protection system

    CERN Document Server

    Romero Aguilar, Angel

    2017-01-01

    PCIe40 is a high-throughput data-acquisition card based on PCI Express that is currently under development for the next upgrade of the LHCb experiment readout system. As part of this development, SMBus is intended to be used as a lightweight, out-of-band protocol to monitor the health of each data acquisition board. Starting from a simple prototype, the student will work on enabling SMBus communication between a COTS linux host and various on-board sensors, on top of existing linux facilities.

  18. Protecting Information in Systems of Systems

    NARCIS (Netherlands)

    Trivellato, Daniel; Zannone, Nicola; Etalle, Sandro

    2011-01-01

    Systems of Systems (SoS) are dynamic, distributed coalitions of autonomous and heterogeneous systems that collaborate to achieve a common goal. While offering several advantages in terms of scalability and flexibility, the SoS paradigm has a strong impact on system interoperability and on the

  19. Power system EMP protection. Final report

    International Nuclear Information System (INIS)

    Marable, J.H.; Barnes, P.R.; Nelson, D.B.

    1975-05-01

    Voltage transients induced in electric power lines and control circuits by the electromagnetic pulse (EMP) from high-altitude nuclear detonations may cause widespread power failure and damage in electric power systems. This report contains a parametric study of EMP power line surges and discusses protective measures to minimize their effects. Since EMP surges have considerably greater rates of rise than lightning surges, recommended standards and test procedures are given to assure that surge arresters protect equipment from damage by EMP. Expected disturbances and damage to power systems are reviewed, and actions are presented which distribution companies can take to counter them. These include backup communications methods, stockpiling of vulnerable parts, repair procedures, and dispatcher actions to prevent blackout from EMP-caused instabilities. A long-range program is presented for improving distributors' protection against EMP. This involves employee training, hardware protection for power and control circuits, and improvement of plans for emergency action. (U.S.)

  20. Development and Field Testing of the FootFall Planning System for the ATHLETE Robots

    Science.gov (United States)

    SunSpiral, Vytas; Wheeler, D. W.; Chavez-Clementa, Daniel; Mittman, David

    2011-01-01

    The FootFall Planning System is a ground-based planning and decision support system designed to facilitate the control of walking activities for the ATHLETE (All-Terrain Hex-Limbed Extra-Terrestrial Explorer) family of robots. ATHLETE was developed at NASA's Jet Propulsion Laboratory (JPL) and is a large six-legged robot designed to serve multiple roles during manned and unmanned missions to the Moon; its roles include transportation, construction and exploration. Over the four years from 2006 through 2010 the FootFall Planning System was developed and adapted to two generations of the ATHLETE robots and tested at two analog field sites (the Human Robotic Systems Project's Integrated Field Test at Moses Lake, Washington, June 2008, and the Desert Research and Technology Studies (D-RATS), held at Black Point Lava Flow in Arizona, September 2010). Having 42 degrees of kinematic freedom, standing to a maximum height of just over 4 meters, and having a payload capacity of 450 kg in Earth gravity, the current version of the ATHLETE robot is a uniquely complex system. A central challenge to this work was the compliance of the high-DOF (Degree Of Freedom) robot, especially the compliance of the wheels, which affected many aspects of statically-stable walking. This paper will review the history of the development of the FootFall system, sharing design decisions, field test experiences, and the lessons learned concerning compliance and self-awareness.

  1. DLP-systems: Protection from Insiders

    Directory of Open Access Journals (Sweden)

    Ivan Sergeevich Boridko

    2013-02-01

    Full Text Available In the paper the necessity of further introduction of modern systems of information protection against internal leaks, including DLP-systems, is justified. The issues of development of training specialists in the field of information security is considered.

  2. Racial Disparity in Minnesota's Child Protection System

    Science.gov (United States)

    Johnson, Erik P.; Clark, Sonja; Donald, Matthew; Pedersen, Rachel; Pichotta, Catherine

    2007-01-01

    Minnesota has been recognized by several studies as a state with a significant amount of racial disparity in its child protection system. This study, using 2001 data from Minnesota's Social Services Information Service, was conducted to determine at which of the six decision points in Minnesota's child welfare system racial disparities are…

  3. Renovation of the cathodic protection system

    NARCIS (Netherlands)

    Schuten, G.; Leggedoor, J.; Polder, R.B.; Peelen, W.H.A.

    2003-01-01

    The first system for Cathodic Protection of concrete in the Netherlands was applied to a one bicycle lane of a bridge suffering corrosion due to de-icing salt penetration in 1986. This CP system was based on the Ferex 100S conducting polymer cable anode in a cementitious overlay. Its functioning was

  4. Future Interoperability of Camp Protection Systems (FICAPS)

    Science.gov (United States)

    Caron, Sylvie; Gündisch, Rainer; Marchand, Alain; Stahl, Karl-Hermann

    2013-05-01

    The FICAPS Project has been established as a Project of the European Defence Agency based on an initiative of Germany and France. Goal of this Project was to derive Guidelines, which by a proper implementation in future developments improve Camp Protection Systems (CPS) by enabling and improving interoperability between Camp Protection Systems and its Equipments of different Nations involved in multinational missions. These Guidelines shall allow for: • Real-time information exchange between equipments and systems of different suppliers and nations (even via SatCom), • Quick and easy replacement of equipments (even of different Nations) at run-time in the field by means of plug and play capability, thus lowering the operational and logistic costs and making the system highly available, • Enhancement of system capabilities (open and modular systems) by adding new equipment with new capabilities (just plug-in, automatic adjustment of the HMI Human Machine Interface) without costly and time consuming validation and test on system level (validation and test can be done on Equipment level), Four scenarios have been identified to summarize the interoperability requirements from an operational viewpoint. To prove the definitions given in the Guideline Document, a French and a German Demonstration System, based on existing national assets, were realized. Demonstrations, showing the capabilities given by the defined interoperability requirements with respect to the operational scenarios, were performed. Demonstrations included remote control of a CPS by another CPS, remote sensor control (Electro-Optic/InfraRed EO/IR) and remote effector control. This capability can be applied to extend the protection area or to protect distant infrastructural assets Demonstrations have been performed. The required interoperability functionality was shown successfully. Even if the focus of the FICAPS project was on camp protection, the solution found is also appropriate for other

  5. Photovoltaic powered regulated cathodic protection system

    Energy Technology Data Exchange (ETDEWEB)

    Anis, W.R.; Alfons, H.A. (Ain Shams Univ., Cairo (Egypt))

    1994-08-01

    The cathodic protection (CP) system objective is to protect metallic structures against corrosion caused by chemical reaction between metallic structures and surrounding mediums, such as soil or water. To overcome such a problem, a sacrificing anode is connected to the protected structure (which acts as a cathode) through a DC power supply. As a result, a current passes from the sacrificing anode to the protected cathode. This leads to anode corrosion rather than causing the cathode (protected structure) corrosion. To stop the corrosion, the protected structure requires a constant current determined by structure metal, area, and the surrounding medium. The major difficulty in achieving this condition is the variation of surrounding medium resistivity due to climatic condition changes. For example, rains as well as humidity decrease soil resistivity, and as a result the DC current increases and a harmful overprotection may take place. Both corrosion and overprotection are harmful for the metallic structure. Conventional CP systems resolve this problem by manual adjustment of DC voltage periodically to obtain a constant current. Such adjustment depends on the personal experience of the technician and the accuracy of the measuring equipment used. Accordingly, the adjustment is subject to personal and measuring equipment errors. Moreover, if the internal between two successive adjustment is relatively long, structure corrosion becomes significant, which may have drastic consequences. To overcome the aforementioned difficulties associated with the conventional CP system, an automatically regulated CP system is discussed in this article. The proposed system senses the variations of the surrounding medium resistivity and adjusts the DC voltage of the system automatically so that the DC current is kept constant at the required level. The design of a solar photovoltaic system to supply the CP system by the required DC power is also discussed.

  6. Management information system on radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela, E-mail: pabloag@cdtn.b, E-mail: lss@cdtn.b, E-mail: gmf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  7. Improved core protection calculator system algorithm

    International Nuclear Information System (INIS)

    Yoon, Tae Young; Park, Young Ho; In, Wang Kee; Bae, Jong Sik; Baeg, Seung Yeob

    2009-01-01

    Core Protection Calculator System (CPCS) is a digitized core protection system which provides core protection functions based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels which adapted a two out of four trip logic. CPCS algorithm improvement for the newly designed core protection calculator system, RCOPS (Reactor COre Protection System), is described in this paper. New features include the improvement of DNBR algorithm for thermal margin, the addition of pre trip alarm generation for auxiliary trip function, VOPT (Variable Over Power Trip) prevention during RPCS (Reactor Power Cutback System) actuation and the improvement of CEA (Control Element Assembly) signal checking algorithm. To verify the improved CPCS algorithm, CPCS algorithm verification tests, 'Module Test' and 'Unit Test', would be performed on RCOPS single channel facility. It is expected that the improved CPCS algorithm will increase DNBR margin and enhance the plant availability by reducing unnecessary reactor trips

  8. Management information system on radiation protection

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela

    2011-01-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  9. Retrieval-travel-time model for free-fall-flow-rack automated storage and retrieval system

    Science.gov (United States)

    Metahri, Dhiyaeddine; Hachemi, Khalid

    2018-03-01

    Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval-travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for drug distribution. This system is a new variation of flow-rack AS/RS that uses an operator or a single machine for storage operations, and uses a combination between the free-fall movement and a transport conveyor for retrieval operations. The main contribution of this paper is to develop an analytical model of the expected retrieval-travel time for the free-fall flow-rack under a dedicated storage assignment policy. The proposed model, which is based on a continuous approach, is compared for accuracy, via simulation, with discrete model. The obtained results show that the maximum deviation between the continuous model and the simulation is less than 5%, which shows the accuracy of our model to estimate the retrieval time. The analytical model is useful to optimise the dimensions of the rack, assess the system throughput, and evaluate different storage policies.

  10. Insulating and protecting systems for a circuit

    International Nuclear Information System (INIS)

    Lemercier, Guy.

    1975-01-01

    The invention concerns a device for insulating and protecting systems or pipework carrying liquid sodium in fast neutron nuclear reactor installations or water or superheated steam. This device considerably lowers the risks whilst making it possible to give the insulating improved mechanical strength, without limiting its thermal protection performance and particularly to build into this insulating a protection and safety barrier against projections of the fluid outwards should the system burst accidentally. To this effect, the device considered includes on the outer surface of the system at least two successive windings of a continuous and long strip composed of a flat sock in knitted metal, comprising transversal openings to provide communication between the inside and outside of the sock, such openings allowing the insertion of thin successive metal sheets extending over the length of the strip [fr

  11. Whole-brain grey matter density predicts balance stability irrespective of age and protects older adults from falling.

    Science.gov (United States)

    Boisgontier, Matthieu P; Cheval, Boris; van Ruitenbeek, Peter; Levin, Oron; Renaud, Olivier; Chanal, Julien; Swinnen, Stephan P

    2016-03-01

    Functional and structural imaging studies have demonstrated the involvement of the brain in balance control. Nevertheless, how decisive grey matter density and white matter microstructural organisation are in predicting balance stability, and especially when linked to the effects of ageing, remains unclear. Standing balance was tested on a platform moving at different frequencies and amplitudes in 30 young and 30 older adults, with eyes open and with eyes closed. Centre of pressure variance was used as an indicator of balance instability. The mean density of grey matter and mean white matter microstructural organisation were measured using voxel-based morphometry and diffusion tensor imaging, respectively. Mixed-effects models were built to analyse the extent to which age, grey matter density, and white matter microstructural organisation predicted balance instability. Results showed that both grey matter density and age independently predicted balance instability. These predictions were reinforced when the level of difficulty of the conditions increased. Furthermore, grey matter predicted balance instability beyond age and at least as consistently as age across conditions. In other words, for balance stability, the level of whole-brain grey matter density is at least as decisive as being young or old. Finally, brain grey matter appeared to be protective against falls in older adults as age increased the probability of losing balance in older adults with low, but not moderate or high grey matter density. No such results were observed for white matter microstructural organisation, thereby reinforcing the specificity of our grey matter findings. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. [Evaluation of postural control systems in elderly patients with repeated falls].

    Science.gov (United States)

    González Ramírez, Alfonso; Lázaro del Nogal, Montserrat; Ribera Casado, José Manuel

    2008-01-01

    a) to describe postural control disorders in elderly patients with recurrent falls; b) to analyze the influence of sensory deficits on centre of gravity control mechanisms; and c) to assess the functional consequences of balance disorders and falls in this group of patients. patients aged more than 65 years old referred to a falls unit with two or more falls in the previous 6 months were included in this study. The protocol included posturographic studies with a Neurocom Balance Master. To evaluate motor control, Rhythmic Weight Shift (RWS test) was performed. To assess sensorial control, Modified Clinical Test of Sensory Interaction on Balance (MCT test) was used. Other tests performed were the Sit to Stand (SS test), Walk across (WA test) and Step up over (SO test). a total of 109 patients (85.3% women) were studied. Mean age was 78.01 years (SD: 5.38). Disorders in one or more afferent sensorial systems were found in 51.7% of the patients (27.5% visual deficiencies, 17.6% vestibular alterations, and 6.6% somatosensorial deficits). Two afferent systems were compromised in 25.3%, and all three were compromised in 11.1% of the patients. No significant differences were found in directional control (RWS) when compared with the number of altered systems. posturographic studies provide sensitive information on static and dynamic centre of gravity control systems, eventual sensory deficits, and patients' ability to carry out basic activities of daily living. In our sample, the most frequent deficit was visual impairment. This information is essential to establish a correct management programme.

  13. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2005-11-01

    One of the main challenges facing radiological protection experts is how to integrate radiological protection within modern concepts of and approaches to risk governance. It is within this context that the International Commission on Radiological Protection (ICRP) decided to develop new general recommendations to replace its Publication 60 recommendations of 1990. In the process of developing these new recommendations, the views of the ICRP have evolved significantly, largely due to stakeholder involvement that has been actively solicited by the ICRP. In this regard, it was upheld during the First Asian Regional Conference organised by the NEA in October 2002 that the implementation of the new system must allow for regional, societal and cultural differences. In order to ensure appropriate consideration of these differences, the NEA organised the Second Asian Regional Conference on the Evolution of the System of Radiological Protection. Held in Tokyo on 28-29 July 2004, the conference included presentations by the ICRP Chair as well as by radiological experts from Australia, China, Japan and Korea. Within their specific cultural and socio-political milieu, Asia-Pacific and western ways of thought on how to improve the current system of radiological protection were presented and discussed. These ways of thinking, along with a summary of the conference results, are described in these proceedings. (author)

  14. INTEGRATED PROTECTIVE FABRIC SYSTEM (IPFS) PHASE III PROGRAM: AEROSOL PROTECTION REPORT

    Science.gov (United States)

    2017-08-16

    TECHNICAL REPORT AD ________________ NATICK/TR-17/021 INTEGRATED PROTECTIVE...September 2015 4. TITLE AND SUBTITLE INTEGRATED PROTECTIVE FABRIC SYSTEM (IPFS) PHASE III PROGRAM: AEROSOL PROTECTION REPORT 5a. CONTRACT NUMBER...materials and configurations investigated in this study. 1 INTEGRATED PROTECTIVE FABRIC SYSTEM (IPFS) PHASE III PROGRAM: AEROSOL PROTECTION REPORT 1

  15. An expert system for the quantification of fault rates in construction fall accidents.

    Science.gov (United States)

    Talat Birgonul, M; Dikmen, Irem; Budayan, Cenk; Demirel, Tuncay

    2016-01-01

    Expert witness reports, prepared with the aim of quantifying fault rates among parties, play an important role in a court's final decision. However, conflicting fault rates assigned by different expert witness boards lead to iterative objections raised by the related parties. This unfavorable situation mainly originates due to the subjectivity of expert judgments and unavailability of objective information about the causes of accidents. As a solution to this shortcoming, an expert system based on a rule-based system was developed for the quantification of fault rates in construction fall accidents. The aim of developing DsSafe is decreasing the subjectivity inherent in expert witness reports. Eighty-four inspection reports prepared by the official and authorized inspectors were examined and root causes of construction fall accidents in Turkey were identified. Using this information, an evaluation form was designed and submitted to the experts. Experts were asked to evaluate the importance level of the factors that govern fall accidents and determine the fault rates under different scenarios. Based on expert judgments, a rule-based expert system was developed. The accuracy and reliability of DsSafe were tested with real data as obtained from finalized court cases. DsSafe gives satisfactory results.

  16. Significant vestibular system impairment is common in a cohort of elderly patients referred for assessment of falls risk.

    Science.gov (United States)

    Jacobson, Gary P; McCaslin, Devin L; Grantham, Sarah L; Piker, Erin G

    2008-01-01

    Falls in elderly patients are associated with morbidity, mortality, and cost to the healthcare system. The development of falls risk assessment programs have represented a method of responding to what is known about injurious falls. The multidimensional assessments involve the comparison against normative data of a patient's performance on metrics known to influence the likelihood of future falls. The factors assessed usually include falls and medication history, measures of mentation, depression, orthostatic hypotension, simple or choice reaction time, gait stability, postural stability, and the integrity of the patient's vision, somesthetic, and vestibular senses. This investigation was conducted to measure the proportion of patients referred for falls risk assessment who have evidence of vestibular system impairment. Qualitative, retrospective review of data collected from 2003 to 2007. The cohort was 185 consecutive patients referred for multidimensional assessments of falls risk. Patients underwent quantitative assessments of peripheral and central vestibular system function consisting of electro- or videonystagmography (i.e., ENG/VNG), and sinusoidal harmonic acceleration testing. Results of these tests were compared to normative data. We found that 73% of the sample who underwent vestibular system assessment had quantitative evidence of either peripheral or central vestibular system impairment. Our results suggest that quantitative assessments of the vestibulo-ocular reflex should be conducted on patients who are evaluated for falls risk. These examinations should include at least caloric testing and, where available, rotational testing.

  17. An integrated numerical protection system (SPIN)

    International Nuclear Information System (INIS)

    Savornin, J.L.; Bouchet, J.M.; Furet, J.L.; Jover, P.; Sala, A.

    1978-01-01

    Developments in technology have now made it possible to perform more sophisticated protection functions which follow more closely the physical phenomena to be monitored. For this reason the Commissariat a l'energie atomique, Merlin-Gerin, Cerci and Framatome have embarked on the joint development of an Integrated Numerical Protection System (SPIN) which will fulfil this objective and will improve the safety and availability of power stations. The system described involves the use of programmed numerical techniques and a structure based on multiprocessors. The architecture has a redundancy of four. Throughout the development of the project the validity of the studies was confirmed by experiments. A first numerical model of a protection function was tested in the laboratory and is now in operation in a power station. A set of models was then introduced for checking the main components of the equipment finally chosen prior to building and testing a prototype. (author)

  18. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2004-01-01

    The development of new radiological protection recommendations by the International Commission on Radiological Protection (ICRP) continues to be a strategically important undertaking, both nationally and internationally. With the growing recognition of the importance of stakeholder aspects in radiological protection decision making, regional and cultural aspects have also emerged as having potentially significant influence on how protection of the public, workers and the environment are viewed. Differing cultural aspects should therefore be considered by the ICRP in its development of new recommendations. Based on this assumption, the NEA organised the Asian Regional Conference on the Evolution of the System of Radiological Protection to express and explore views from the Far East. Held in Tokyo on 24-25 October 2002, the conference included presentations by the ICRP Chair as well as by radiological protection experts from Japan, the Republic of Korea, China and Australia. The distinct views and needs of these countries were discussed in the context of their regional and cultural heritages. These views, along with a summary of the conference results, are presented in these proceedings. (author)

  19. Distance Protection for Microgrids in Distribution System

    DEFF Research Database (Denmark)

    Lin, Hengwei; Liu, Chengxi; Guerrero, Josep M.

    2015-01-01

    Owing to the increasing penetration of distributed generation, there are some challenges for the conventional protection in distribution system. Bidirectional power flow and variable fault current because of the various operation modes may lead to the selectivity and sensitivity of the overcurrent...

  20. Validation of reactor core protection system

    International Nuclear Information System (INIS)

    Lee, Sang-Hoon; Bae, Jong-Sik; Baeg, Seung-Yeob; Cho, Chang-Ho; Kim, Chang-Ho; Kim, Sung-Ho; Kim, Hang-Bae; In, Wang-Kee; Park, Young-Ho

    2008-01-01

    Reactor COre Protection System (RCOPS), an advanced core protection calculator system, is a digitized one which provides core protection function based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels adapted a two-out-of-four trip logic. System configuration, hardware platform and an improved algorithm of the newly designed core protection calculator system are described in this paper. One channel of RCOPS was implemented as a single channel facility for this R and D project where we performed final integration software testing. To implement custom function blocks, pSET is used. Software test is performed by two methods. The first method is a 'Software Module Test' and the second method is a 'Software Unit Test'. New features include improvement of core thermal margin through a revised on-line DNBR algorithm, resolution of the latching problem of control element assembly signal and addition of the pre-trip alarm generation. The change of the on-line DNBR calculation algorithm is considered to improve the DNBR net margin by 2.5%-3.3%. (author)

  1. Additional reactor protection system of RBMK-1500

    International Nuclear Information System (INIS)

    1999-01-01

    Analysis of anticipated transients without scram of RBMK-1500 reactor showed that additional reactor protection system is required. Data of accident analysis in the case of loose of external electric power and loose of vacuum in condensers of turbines are provided

  2. Safety Analysis for Power Reactor Protection System

    International Nuclear Information System (INIS)

    Eisawy, E.A.; Sallam, H.

    2012-01-01

    The main function of a Reactor Protection System (RPS) is to safely shutdown the reactor and prevents the release of radioactive materials. The purpose of this paper is to present a technique and its application for used in the analysis of safety system of the Nuclear Power Plant (NPP). A more advanced technique has been presented to accurately study such problems as the plant availability assessments and Technical Specifications evaluations that are becoming increasingly important. The paper provides the Markov model for the Reactor Protection System of the NPP and presents results of model evaluations for two testing policies in technical specifications. The quantification of the Markov model provides the probability values that the system will occupy each of the possible states as a function of time.

  3. Regulatory System of Radiation Protection in Taiwan

    International Nuclear Information System (INIS)

    Tang, F. T.; Huang, C. C.

    2004-01-01

    After the radioactive contaminated buildings incident occurred in Taiwan in 1993, the competent authority for radiation protection the Atomic Energy Council (AEC) started to review the structured problem of radiation protection regulatory system. Through several years' investigation and study, the AEC has improved two important tools in radiation protection regulatory system, i.e., control regulations and actual practice, and made them more rigorous and efficient. This paper will make a brief introduction of the efforts that Taiwan has made in this respect. Taiwan's radiation protection control was based on the Atomic Energy Law promulgated in 1968, but the control idea and authorization scope were not sufficient to appropriately respond to the highly developed economy and democracy in Taiwan. After several years' legislative process, the Ionizing Radiation Protection Law (IRP Law) was promulgated and entered into force on February 1, 2003. This IRP Law specifically emphasizes categorized risk management of radiation sources, establishment of personnel licenses and training system, enhancement of public safety control, and implementation of quality assurance program for medical exposure. The Legislative Yuan (Congress) fully authorized the competent authority to establish various technological control regulations according to control necessity without prior review by the Legislative Yuan in advance. As to the penalties of the violations of the IRP Law, the AEC adopts high-rated administrative fines and applies the Criminal Law to those who seriously contaminate the environment. In actual practice, the AEC has constructed a Radiation Protection Control Information System compatible with the IRP Law that fully combines the functions of computers and Internet. The information of facility operators who own radiation sources, radiation protection specialists, and operating personnel are entered into this system, starting from the submission of application of the

  4. Experimental assessment of an absorption cooling system utilizing a falling film absorber and generator

    International Nuclear Information System (INIS)

    Domínguez-Inzunza, L.A.; Hernández-Magallanes, J.A.; Soto, P.; Jiménez, C.; Gutiérrez-Urueta, G.; Rivera, W.

    2016-01-01

    Highlights: • A new prototype of an absorption cooling system using NH 3 /LiNO 3 was developed. • Falling films shell and tubes heat exchangers were used as absorber and generator. • Evaporator temperatures as low as 4 °C were achieved. • The COP varied between 0.27 and 0.62 depending on the system temperatures. • A flow recirculation in the absorber was implemented showing an increase in COP. - Abstract: This study presents the results of the evaluation of an ammonia/lithium nitrate absorption cooling system. The generator and the absorber are shell and tubes falling film heat exchangers while the rest of the components are compact plate heat exchangers. A parametric study was carried out in order to determine the coefficients of performance and cooling capacities at different operating conditions. Also, an analysis was carried out to determine the influence of the absorber solution recirculation on the system performance. The generator temperatures varied between 80 °C and 100 °C, while the cooling water temperatures varied from 20 °C to 34 °C. Cooling capacities up to 4.5 kW and evaporator temperatures as low as 4 °C were achieved with the system. The internal coefficients of performance varied between 0.3 and 0.62 depending on the system operating temperatures. The system also showed good stability and repeatability.

  5. Healthcare Providers’ Perceptions and Self-Reported Fall Prevention Practices: Findings from a Large New York Health System

    Directory of Open Access Journals (Sweden)

    Matthew Lee eSmith

    2015-04-01

    Full Text Available Among older adults, falls are the leading cause of injury-related deaths and emergency department visits, and the incidence of falls in the United States is rising as the number of older Americans increases. Research has shown that falls can be reduced by modifying fall risk factors using multifactorial interventions implemented in clinical settings. However, the literature indicates many providers feel they do not know how to conduct fall risk assessments or do not have adequate knowledge about fall prevention To help healthcare providers incorporate older adult fall prevention (i.e., falls risk assessment and treatment into their clinical practice, the Centers for Disease Control and Prevention’s (CDC Injury Center has developed the STEADI (Stopping Elderly Accidents, Deaths, and Injuries tool kit. This study was conducted to identify the practice characteristics and providers’ beliefs, knowledge, and fall-related activities before they received training on how to use the STEADI tool kit. Data were collected as part of a larger State Fall Prevention Project funded by CDC’s Injury Center. Completed questionnaires were returned by 38 medical providers from 11 healthcare practices within a large New York health system. Healthcare providers ranked falls as the lowest priority of five conditions, after diabetes, cardiovascular disease, mental health, and musculoskeletal conditions. Less than 40% of the providers asked most or all of their older patients if they had fallen during the past 12 months. Less than a quarter referred their older patients to physical therapists for balance or gait training, and less than 20% referred older patients to community-based fall prevention programs. Less than 16% reported they conducted standardized functional assessments with their older patients at least once a year. These results suggest that implementing the STEADI tool kit in clinical settings could address knowledge gaps and provide the necessary

  6. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  7. In-situ characterization of droplets during free fall in the drop tube-impulse system

    International Nuclear Information System (INIS)

    Khatibi, P Delshad; Ilbagi, A; Henein, H; Beinker, D

    2011-01-01

    Powders of copper were produced using a drop tube-impulse atomization technique. In this system, molten metal is pushed through orifices, forming ligaments, which eventually break down and spherodize into droplets. A 3-D translation stage was designed, constructed and installed in the drop tube to allow for measurements of velocity and droplet size in flight using a Shadowgraph and radiant energy using DPV-2000. A mathematical model of the evolution of droplet velocity and temperature for different sized copper droplets at various heights was developed. The experimental results from the Shadowgraph and the DPV-2000 are compared to the model's results. In addition, the extent to which microgravity prevails during flight and droplet solidification was investigated by using the model and the Shadowgraph results. It was found that the acceleration of falling droplets near the melting point is close to gravitational acceleration and as a result the falling droplets do not reach their terminal velocity at their melting point. The results of in-situ measurements during the atomization of copper showed that the larger droplets have higher radiant energy than that of the smaller ones. Correlation between experimentally measured radiant energy and predicted temperature of falling droplets will be investigated. The current work is part of the NEQUISOL project supported by ESA within contract number 15236/02/NL/SH and CSA within contract number 9F007-08-0154 and SSEP Grant 2008.

  8. Incipient fault detection and power system protection for spaceborne systems

    Science.gov (United States)

    Russell, B. Don; Hackler, Irene M.

    1987-01-01

    A program was initiated to study the feasibility of using advanced terrestrial power system protection techniques for spacecraft power systems. It was designed to enhance and automate spacecraft power distribution systems in the areas of safety, reliability and maintenance. The proposed power management/distribution system is described as well as security assessment and control, incipient and low current fault detection, and the proposed spaceborne protection system. It is noted that the intelligent remote power controller permits the implementation of digital relaying algorithms with both adaptive and programmable characteristics.

  9. Image-based fall detection and classification of a user with a walking support system

    Science.gov (United States)

    Taghvaei, Sajjad; Kosuge, Kazuhiro

    2017-10-01

    The classification of visual human action is important in the development of systems that interact with humans. This study investigates an image-based classification of the human state while using a walking support system to improve the safety and dependability of these systems.We categorize the possible human behavior while utilizing a walker robot into eight states (i.e., sitting, standing, walking, and five falling types), and propose two different methods, namely, normal distribution and hidden Markov models (HMMs), to detect and recognize these states. The visual feature for the state classification is the centroid position of the upper body, which is extracted from the user's depth images. The first method shows that the centroid position follows a normal distribution while walking, which can be adopted to detect any non-walking state. The second method implements HMMs to detect and recognize these states. We then measure and compare the performance of both methods. The classification results are employed to control the motion of a passive-type walker (called "RT Walker") by activating its brakes in non-walking states. Thus, the system can be used for sit/stand support and fall prevention. The experiments are performed with four subjects, including an experienced physiotherapist. Results show that the algorithm can be adapted to the new user's motion pattern within 40 s, with a fall detection rate of 96.25% and state classification rate of 81.0%. The proposed method can be implemented to other abnormality detection/classification applications that employ depth image-sensing devices.

  10. Distribution system protection with communication technologies

    DEFF Research Database (Denmark)

    Wei, Mu; Chen, Zhe

    2010-01-01

    Due to the communication technologies’ involvement in the distribution power system, the time-critical protection function may be implemented more accurately, therefore distribution power systems’ stability, reliability and security could be improved. This paper presents an active distribution...... power system, including CHPs (Combined Heating and Power) and small scaled WTs (Wind Turbines), as a practical example to examine the possible impacts of communication technologies on the power system. Under some fault scenarios, the power system’s responses to the fault are compared between the system...... with communication technologies and that without communication technologies. At the same time, the previously proposed study method of combining the simulations of communication and power systems is adopted in this study. The performance of a communication network adopted for power system is simulated by OPNET...

  11. Development of In-Core Protection System

    International Nuclear Information System (INIS)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H.

    2016-01-01

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project

  12. Development of In-Core Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H. [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project.

  13. Lightning protection system for a wind turbine

    Science.gov (United States)

    Costin, Daniel P [Chelsea, VT; Petter, Jeffrey K [Williston, VT

    2008-05-27

    In a wind turbine (104, 500, 704) having a plurality of blades (132, 404, 516, 744) and a blade rotor hub (120, 712), a lightning protection system (100, 504, 700) for conducting lightning strikes to any one of the blades and the region surrounding the blade hub along a path around the blade hub and critical components of the wind turbine, such as the generator (112, 716), gearbox (708) and main turbine bearings (176, 724).

  14. Collaborative Point Paper on Active Protection Systems

    Science.gov (United States)

    2006-10-01

    support for the Chameleon ECM CIED System. Under the teaming agreement, MES, Plexus Corp. Neenah, WI and Applied Marine Technology, Inc. Hanahan, SC...power mode is used at the general direction of the threat, in a search pattern designed to locate the target’s optics. Once locked on a target, the... locking onto target 7.8- 10.06m from tank; after processing data computer selects countermunition (CM)- protective ammunition housed in 20 silos around

  15. Halon 1301 protection system for nuclear containments

    International Nuclear Information System (INIS)

    McHale, E.T.

    1981-01-01

    Halon 1301 can provide protection against any combustion hazard that hydrogen gas might present in an LWR containment following a loss-of-coolant accident. A development program was conducted, comprising analytical study, laboratory experiments and large-scale testing, to define the requirements for a Halon 1301 system and to examine certain operational problems that were hypothesized. Some results of the study are presented in this paper

  16. Risk and protective factors for falls on one level in young children: multicentre case-control study.

    Science.gov (United States)

    Benford, P; Young, B; Coupland, C; Watson, M; Hindmarch, P; Hayes, M; Goodenough, T; Majsak-Newman, G; Kendrick, D

    2015-12-01

    Childhood falls are an important global public health problem, but there is lack of evidence about their prevention. Falls on one level result in considerable morbidity and they are costly to health services. To estimate ORs for falls on one level in children aged 0-4 years for a range of safety behaviours, safety equipment use and home hazards. Multicentre case-control study at hospitals, minor injury units and general practices in and around four UK study centres. Participants included 582 children less than 5 years of age with a medically attended fall injury occurring at home and 2460 controls matched on age, sex, calendar time and study centre. Fall on one level. Cases' most common injuries were bangs on the head (52%), cuts or grazes not needing stitches (29%) or cuts or grazes needing stitches (17%). Comparing cases to community controls in the adjusted analyses, significant findings were observed for only two exposures. Injured children were significantly less likely to live in a household without furniture corner covers (adjusted OR (AOR) 0.72, 95% CI 0.55 to 0.95), or without rugs and carpets firmly fixed to the floor (AOR 0.76, 95% CI 0.59 to 0.98). We did not find any safety practices, use of safety equipment or home hazards associated with a reduced risk of fall on one level. Our findings do not provide evidence to support changes to current injury prevention practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Enhanced personal protection system for the PS

    CERN Multimedia

    Caroline Duc

    2013-01-01

    During the first long shutdown (LS1) a new safety system will be installed in the primary beam areas of the PS complex in order to bring the standard of personnel radiation protection at the PS into line with that of the LHC.   Pierre Ninin, deputy group leader of GS-ASE and responsible for the installation of the new PS complex safety system, in front of a new access control system. The LHC access control systems are state-of-the-art, whereas those of the injection chain accelerators were running the risk of becoming obsolete. For the past two years a project to upgrade the access and safety systems of the first links in the LHC accelerator chain has been underway to bring them into compliance with nuclear safety standards. These systems provide the personnel with automatic protection by limiting access to hazardous areas and by ensuring that nobody is present in the areas when the accelerator is in operation. By the end of 2013, the project teams will ha...

  18. River Protection Project information systems assessment

    International Nuclear Information System (INIS)

    JOHNSON, A.L.

    1999-01-01

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report

  19. River Protection Project information systems assessment

    Energy Technology Data Exchange (ETDEWEB)

    JOHNSON, A.L.

    1999-07-28

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report.

  20. Integrated nuclear and radiation protection systems

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, V.; Cerga, V.; Pirvu, V.; Badea, E.

    1993-01-01

    A multifunctional radiation monitoring equipment, flexible and capable to meet virtually environmental radiation monitoring, activity measurement and computational requirements, for nuclear laboratories has been designed. It can be used as a radiation protection system, for radionuclide measurement in isotope laboratories, nuclear technology, health physics and nuclear medicine, nuclear power stations and nuclear industry. The equipment is able to measure, transmit and record gamma dose rate and isotope activities. Other parameters and functions are optionally available, such as: self-contained alarm level, system self-test, dose integrator, syringe volume calculation for a given dose corrected for decay, calibration factor, 99 Mo assays performing and background subtraction

  1. Commercial application of thermal protection system technology

    Science.gov (United States)

    Dyer, Gordon L.

    1991-01-01

    The thermal protection system process technology is examined which is used in the manufacture of the External Tank for the Space Shuttle system and how that technology is applied by private business to create new products, new markets, and new American jobs. The term 'technology transfer' means different things to different people and has become one of the buzz words of the 1980s and 1990s. Herein, technology transfer is defined as a means of transferring technology developed by NASA's prime contractors to public and private sector industries.

  2. The run permit protection system for GTA

    International Nuclear Information System (INIS)

    Atkins, W.H.; Jones, R.G.

    1992-01-01

    A Run Permit system has been designed for the Ground Test Accelerator (GTA). The system implements mode-dependent software interlocks to ensure proper operation of the accelerator, enabling the ion source extractor and RF systems when proper conditions are met. The system is implemented using the GTA control system; thus all information available to the control system is also available for use in interlock logic. The logic is defined in terms of control system channels, which reflect accelerator parameters such as actuator positions, power supply values, temperatures, etc. A mode switch in the control room selects the accelerator operating mode, for example i njector only . The Run Permit software selects interlock logic as appropriate operating mode. This implementation easily accommodates logic changes as requirements evolve. To ensure reliable operation of a software-based system, a special circuit with a watch-dog timer is employed to produce the system's output signals. The software must periodically address the circuit, or the output signals are forced to a disabled state. For additional protection, there are self-test provisions for detecting and reacting to failures of the control system. (Author) 4 figs., ref

  3. An Active Englacial Hydrological System in a Cold Glacier: Blood Falls, Taylor Glacier, Antarctica

    Science.gov (United States)

    Carr, C. G.; Pettit, E. C.; Carmichael, J.; Badgeley, J.; Tulaczyk, S. M.; Lyons, W. B.; Mikucki, J.

    2016-12-01

    Blood Falls is a supraglacial hydrological feature formed by episodic release of iron-rich subglacial brine derived from an extensive aquifer beneath the cold, polar, Taylor Glacier. While fluid transport in non-temperate ice typically occurs through meltwater delivery from the glacier surface to the bed (hydrofracturing, supraglacial lake drainage), Blood Falls represents the opposite situation: brine moves from a subglacial source to the glacier surface. Here, we present the first complete conceptual model for brine transport and release, as well as the first direct evidence of a wintertime brine release at Blood Falls obtained through year-round time-lapse photography. Related analyses show that brine pools subglacially underneath the northern terminus of Taylor Glacier, rather than flowing directly into proglacial Lake Bonney because ice-cored moraines and channelized surface topography provide hydraulic barriers. This pooled brine is pressurized by hydraulic head from the upglacier brine source region. Based on seismic data, we propose that episodic supraglacial release is initiated by high strain rates coupled with pressurized subglacial brine that drive intermittent subglacial and englacial fracturing. Ultimately, brine-filled basal crevasses propagate upward to link with surface crevasses, allowing brine to flow from the bed to the surface. The observation of wintertime brine release indicates that surface-generated meltwater is not necessary to trigger crack propagation or to maintain the conduit as previously suggested. The liquid brine persists beneath and within the cold ice (-17°C) despite ambient ice/brine temperature differences of as high as 10°C through both locally depressed brine freezing temperatures through cryoconcentration of salts and increased ice temperatures through release of latent heat during partial freezing of brine. The existence of an englacial hydrological system initiated by basal crevassing extends to polar glaciers a process

  4. National Ignition Facility environmental protection systems

    International Nuclear Information System (INIS)

    Mintz, J.M.; Reitz, T.C.; Tobin, M.T.

    1994-06-01

    The conceptual design of Environmental Protection Systems (EPS) for the National Ignition Facility (NIF) is described. These systems encompass tritium and activated debris handling, chamber, debris shield and general decontamination, neutron and gamma monitoring, and radioactive, hazardous and mixed waste handling. Key performance specifications met by EPS designs include limiting the tritium inventory to 300 Ci and total tritium release from NIF facilities to less than 10 Ci/yr. Total radiation doses attributable to NIF shall remain below 10 mrem/yr for any member of the general public and 500 mrem/yr for NIF staff. ALARA-based design features and operational procedures will, in most cases, result in much lower measured exposures. Waste minimization, improved cycle time and reduced exposures all result from the proposed CO2 robotic arm cleaning and decontamination system, while effective tritium control is achieved through a modern system design based on double containment and the proven detritiation technology

  5. Radiological protection national system. Basic security rules

    International Nuclear Information System (INIS)

    1981-01-01

    This work has been prepared as the first one of a set of standards and regulations that will be enforced to provide the protection of men and the environment against the undesirable effects of ionizing radiations. It establishes, in the first place, the system of dose limits for the country and the principles of its utilization. It takes into account the CIPR's recommendations in this area and the mentioned frame of reference, it establishes further the necessary restrictions for the application of the limits to the professionally exposed workers, as well as to the isolated members of the public and the population in general. In addition it establishes the general conditions to be met for the implementation of radiological protection, among them, the classification of working areas and working conditions as well as the compulsory periodical medical surveillance. (H.D.N.)

  6. Equivalence principle for quantum systems: dephasing and phase shift of free-falling particles

    Science.gov (United States)

    Anastopoulos, C.; Hu, B. L.

    2018-02-01

    We ask the question of how the (weak) equivalence principle established in classical gravitational physics should be reformulated and interpreted for massive quantum objects that may also have internal degrees of freedom (dof). This inquiry is necessary because even elementary concepts like a classical trajectory are not well defined in quantum physics—trajectories originating from quantum histories become viable entities only under stringent decoherence conditions. From this investigation we posit two logically and operationally distinct statements of the equivalence principle for quantum systems. Version A: the probability distribution of position for a free-falling particle is the same as the probability distribution of a free particle, modulo a mass-independent shift of its mean. Version B: any two particles with the same velocity wave-function behave identically in free fall, irrespective of their masses. Both statements apply to all quantum states, including those without a classical correspondence, and also for composite particles with quantum internal dof. We also investigate the consequences of the interaction between internal and external dof induced by free fall. For a class of initial states, we find dephasing occurs for the translational dof, namely, the suppression of the off-diagonal terms of the density matrix, in the position basis. We also find a gravitational phase shift in the reduced density matrix of the internal dof that does not depend on the particle’s mass. For classical states, the phase shift has a natural classical interpretation in terms of gravitational red-shift and special relativistic time-dilation.

  7. The rise and fall of a risk-based priority system: Lessons from DOE's Environmental Restoration Priority System

    International Nuclear Information System (INIS)

    Jenni, K.E.; Merkhofer, M.W.; Williams, C.

    1995-01-01

    This paper presents the history of the Environmental Restoration Priority System (ERPS), a decision aid developed by the U.S. Department of Energy (DOE) to help determine how to allocate funds for cleaning up hazardous waste sites. Although praised in technical peer review, the system was strongly criticized by stakeholders external to DOE. Ultimately, and in the midst of a National Academy of Sciences review, DOE shelved the system. The rise and fall of ERPS provides useful lessons for analysts hoping to improve risk management in the public sector. 49 refs., 3 figs., 3 tabs

  8. TREAT Reactor Control and Protection System

    International Nuclear Information System (INIS)

    Lipinski, W.C.; Brookshier, W.K.; Burrows, D.R.; Lenkszus, F.R.; McDowell, W.P.

    1985-01-01

    The main control algorithm of the Transient Reactor Test Facility (TREAT) Automatic Reactor Control System (ARCS) resides in Read Only Memory (ROM) and only experiment specific parameters are input via keyboard entry. Prior to executing an experiment, the software and hardware of the control computer is tested by a closed loop real-time simulation. Two computers with parallel processing are used for the reactor simulation and another computer is used for simulation of the control rod system. A monitor computer, used as a redundant diverse reactor protection channel, uses more conservative setpoints and reduces challenges to the Reactor Trip System (RTS). The RTS consists of triplicated hardwired channels with one out of three logic. The RTS is automatically tested by a digital Dedicated Microprocessor Tester (DMT) prior to the execution of an experiment. 6 refs., 5 figs., 1 tab

  9. Test Report of Media Protection Systems

    National Research Council Canada - National Science Library

    Vella, Victor

    1999-01-01

    ...) conducted an investigation of the fire protection capabilities of commercially available media protection products, specifically those containers that fit inside GSA approved security file cabinets...

  10. 14 CFR 23.1359 - Electrical system fire protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  11. Don’t downplay ‘play’: Reasons why health systems should protect childhood play

    DEFF Research Database (Denmark)

    Nielsen, Lasse

    2018-01-01

    There has been much research on the importance of play for children’s development. However, questions of its political importance and our public institutions’ duties to protect it have been largely neglected. This article argues that childhood play is politically important due to both its intrinsic...... and instrumental value, and it suggests that the duty to protect the capability for play in childhood falls, at least partially, upon the public health system. If this argument holds, it follows that we have stronger duties towards our children than we currently believe....

  12. Neutronic control instrumentation of protection systems

    International Nuclear Information System (INIS)

    Furet, J.

    1977-01-01

    The aims of neutronic control instrumentation are briefly recalled and the present status of materials research and development is presented. As for the out-of-pile instrumentation, emphasis is put on the reliability and efficiency of the detectors and the new solutions of electric signal processing. The possible reactivity measurements at rest are examined. As for in-pile instrumentation results relating to mobile detectors of the type of miniaturized fission chambers are presented. The radiation tests on course of development for several years in the working conditions of neutron self-powdered detectors are analyzed so as to show that their use as built-in in-core instrumentation is to be envisaged at short term. Basic options inherent to the 'Nuclear Safety' philosophy that define the protection system are recalled. A definition and a justification of the performance testing of the instrumentation at rest and in-service are then derived. Some new solutions are envisaged for processing the digital data obtained from the various sensors . A quality control of the materials setting conditions (especially electric noise) ensures a high reliability and availability of the materials involved in the neutron control and the protection system in working conditions [fr

  13. Privacy protection schemes for fingerprint recognition systems

    Science.gov (United States)

    Marasco, Emanuela; Cukic, Bojan

    2015-05-01

    The deployment of fingerprint recognition systems has always raised concerns related to personal privacy. A fingerprint is permanently associated with an individual and, generally, it cannot be reset if compromised in one application. Given that fingerprints are not a secret, potential misuses besides personal recognition represent privacy threats and may lead to public distrust. Privacy mechanisms control access to personal information and limit the likelihood of intrusions. In this paper, image- and feature-level schemes for privacy protection in fingerprint recognition systems are reviewed. Storing only key features of a biometric signature can reduce the likelihood of biometric data being used for unintended purposes. In biometric cryptosystems and biometric-based key release, the biometric component verifies the identity of the user, while the cryptographic key protects the communication channel. Transformation-based approaches only a transformed version of the original biometric signature is stored. Different applications can use different transforms. Matching is performed in the transformed domain which enable the preservation of low error rates. Since such templates do not reveal information about individuals, they are referred to as cancelable templates. A compromised template can be re-issued using a different transform. At image-level, de-identification schemes can remove identifiers disclosed for objectives unrelated to the original purpose, while permitting other authorized uses of personal information. Fingerprint images can be de-identified by, for example, mixing fingerprints or removing gender signature. In both cases, degradation of matching performance is minimized.

  14. Distributed Power-Generation Systems and Protection

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng; Yang, Dongsheng

    2017-01-01

    Continuously expanding deployments of distrib¬uted power-generation systems (DPGSs) are transforming the conventional centralized power grid into a mixed distributed electrical network. The modern power grid requires flexible energy utilization but presents challenges in the case of a high...... penetration degree of renewable energy, among which wind and solar photovoltaics are typical sources. The integration level of the DPGS into the grid plays a critical role in developing sustainable and resilient power systems, especially with highly intermittent renewable energy resources. To address...... for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS...

  15. Advanced power system protection and incipient fault detection and protection of spaceborne power systems

    Science.gov (United States)

    Russell, B. Don

    1989-01-01

    This research concentrated on the application of advanced signal processing, expert system, and digital technologies for the detection and control of low grade, incipient faults on spaceborne power systems. The researchers have considerable experience in the application of advanced digital technologies and the protection of terrestrial power systems. This experience was used in the current contracts to develop new approaches for protecting the electrical distribution system in spaceborne applications. The project was divided into three distinct areas: (1) investigate the applicability of fault detection algorithms developed for terrestrial power systems to the detection of faults in spaceborne systems; (2) investigate the digital hardware and architectures required to monitor and control spaceborne power systems with full capability to implement new detection and diagnostic algorithms; and (3) develop a real-time expert operating system for implementing diagnostic and protection algorithms. Significant progress has been made in each of the above areas. Several terrestrial fault detection algorithms were modified to better adapt to spaceborne power system environments. Several digital architectures were developed and evaluated in light of the fault detection algorithms.

  16. Physical protection system using activated barriers

    International Nuclear Information System (INIS)

    Timm, R.E.; Zinneman, T.E.; Haumann, J.R.; Flaugher, H.A.; Reigle, D.L.

    1984-03-01

    The Argonne National Laboratory has recently installed an activated barrier, the Access Denial System, to upgrade its security. The technology of this system was developed in the late 70's by Sandia National Laboratory-Albuquerque. The Argonne National Laboratory is the first Department of Energy facility to use this device. Recent advancements in electronic components provide the total system support that makes the use of an activated barrier viable and desirable. The premise of an activated barrier is that it is deployed after a positive detection of an adversary is made and before the adversary can penetrate vital area. To accomplish this detection, sophisticated alarms, assessment, and communications must be integrated into a system that permits a security inspector to make a positive evaluation and to activate the barrier. The alarm sensor locations are selected to provide protection in depth. Closed circuit television is used with components that permit multiple video frames to be stored for automated, priority-based playback to the security inspector. Further, algorithms permit look-ahead surveillance of vital areas so that the security inspector can activate the access denial system in a timely manner and not be restricted to following the adversaries' penetration path(s)

  17. Remote monitoring of a Fire Protection System

    Science.gov (United States)

    Bauman, Steven; Vermeulen, Tom; Roberts, Larry; Matsushige, Grant; Gajadhar, Sarah; Taroma, Ralph; Elizares, Casey; Arruda, Tyson; Potter, Sharon; Hoffman, James

    2011-03-01

    Some years ago CFHT proposed developing a Remote Observing Environment aimed at producing Science Observations at their Observatory Facility on Mauna Kea from their Headquarters facility in Waimea, HI. This Remote Observing Project commonly referred to as OAP (Observatory Automation Project) was completed at the end of January 2011 and has been providing the majority of Science Data since. My poster will discuss the upgrades to the existing fire alarm protection system. With no one at the summit during nightly operations, the observatory facility required automated monitoring of the facility for safety to personnel and equipment in the case of a fire. An addressable analog fire panel was installed which utilizes digital communication protocol (DCP), intelligent communication with other devices, and an RS-232 interface which provides feedback and real-time monitoring of the system. Using the interface capabilities of the panel, it provides notifications when heat detectors, smoke sensors, manual pull stations, or the main observatory computer room fire suppression system has been activated. The notifications are sent out as alerts to staff in the form of test massages and emails and the observing control GUI interface alerts the remote telescope operator with a map showing the location of the fire occurrence and type of device that has been triggered. And all of this was accomplished without the need for an outside vendor to monitor the system and facilitate warnings or notifications regarding the system.

  18. 46 CFR 154.1110 - Areas protected by system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Areas protected by system. 154.1110 Section 154.1110... Firefighting § 154.1110 Areas protected by system. Each water spray system must protect: (a) All cargo tank... valves essential to cargo flow; (f) Each boundary facing the cargo area of each superstructure that...

  19. 33 CFR 127.1507 - Water systems for fire protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Water systems for fire protection... systems for fire protection. (a) Each waterfront facility handling LHG must have a supply of water and a... protection for structures, cargo, and vessels. Each water system must include on the pier or wharf at least...

  20. Toilet Assistive System Designed for the Reduction of Accidental Falls in the Bathroom Using Admittance Controller

    Directory of Open Access Journals (Sweden)

    Martin J.-D. Otis

    2017-10-01

    Full Text Available This paper suggests an assistive system for the toilet with the objective of measuring human activities and to provide intelligent mechanical assistance to help seating and standing. The project intends to develop a seating assistance as a technical aid in order to reduce accidents and falls in the bathroom. The preferred technique is human-robot physical interaction algorithms known in collaborative robotics (cobot and adapting it to a personalized assistance technology installed on a smart toilet. First, the design of the mechanical assistance is presented. Then, an admittance controller is designed and implemented in order to help the user in a similar way as a cobot could be used. This technique could be used to assist the user and improve balance with adequate training and an adequate configuration of the admittance controller.

  1. Reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The safety concept requires to ensure that - the reactor protection system - the active engineered safeguard - and the necessary auxiliary systems are so designed and interfaced in respect of design and mode of action that, in the event of single component failure reliable control of the consequences of accidents remains ensured at all times and that the availability of the power plant is not limited unnecessarily. In order to satisfy these requirements due, importance was attached to a consistent spacial separation of the mutually redundant subsystems of the active safety equipment. The design and layout of the reactor protection system, of the power supply (emergency power supply), and of the auxiliary systems important from the safety engineering point of view, are such that their subsystems also largely satisfy the requirements of independence and spacial separation. (orig./RW)

  2. An Evolved System of Radiological Protection

    International Nuclear Information System (INIS)

    Kaneko, M.

    2004-01-01

    The current system of radiological protection based on the Linear No-Threshold (LNT) hypothesis has greatly contributed to the minimization of doses received by workers and members of the public. However, it has brought about r adiophobia a mong people and waste of resources due to over-regulation, because the LNT implies that radiation is harmful no matter how small the dose is. The author reviewed the results of research on health effects of radiation including major epidemiological studies on radiation workers and found no clear evidence of deleterious health effects from radiation exposures below the current maximum dose limits (50 mSv/y for workers and 5 mSv/y for members of the public), which have been adopted worldwide in the second half of the 20th century. Now that the existence of bio-defensive mechanisms such as DNA repair, apoptosis and adaptive response are well recognized, the linearity assumption cannot be said to be s cientific . Evidences increasingly imply that there are threshold effects in risk of radiation. A concept of practical thresholds or virtually safe doses will have to be introduced into the new system of radiological protection in order to resolve the low dose issues. Practical thresholds may be defined as dose levels below which induction of detectable radiogenic cancers or hereditary effects are not expected. If any workers and members of the public do not gain benefits from being exposed, excepting intentional irradiation for medical purposes, their radiation exposures should be kept below practical thresholds. On the assumption that the current dose limits are below practical thresholds and with no radiation detriments, there is no need of justification and optimization (ALARA) principles for occupational and public exposures. Then the ethical issue of justification to allow benefit to society to offset radiation detriments to individuals can be resolved. And also the ethical issue of optimization to exchange health or safety for

  3. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  4. 75 FR 38779 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2010-07-06

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department of... federal, state and territorial marine protected area programs to join the National System of Marine Protected Areas. [[Page 38780

  5. Effects of a Novel Fish Transport System on the Health of Adult Fall Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Geist, David R.; Colotelo, Alison H.; Linley, Timothy J.; Wagner, Katie A.; Miracle, Ann L.

    2016-12-01

    Movement past hydroelectric dams and related in-river structures has important implications for habitat connectivity and population persistence in migratory fish. A major problem is that many of these structures lack effective fish passage facilities, which can fragment spawning and rearing areas and negatively impact recruitment. While traditional fish passage facilities (e.g., ladders, trap and haul) can effectively enable fish to pass over barriers, their capital or operational costs can be significant. We evaluated the utility of a novel transport device that utilizes a flexible tube with differential internal air pressure to pass fish around in-river barriers. Three treatments and a control group were tested. In two of the treatments, adult fall Chinook Salmon nearing maturation were transported through the device via two lengths of tube (12 or 77 m) and their injury, stress, and immune system responses and reproductive function were compared to a third treatment where fish were moved by a standard trap and haul method and also to a control group. We observed no significant differences among the treatment or control groups in post-treatment adult survival, injury or stress. Indicators of immune system response and reproductive readiness were also not significantly different among the four groups. Egg survival was significantly different among the groups, but the differences were highly variable within groups and not consistent with the duration of treatment or degree of handling. Taken together, the results suggest the device did not injure or alter normal physiological functioning of adult fall Chinook Salmon nearing maturation and may provide an effective method for transporting such fish around in-river barriers during their spawning migration. Keywords: Whooshh, transport, in-stream barriers, hydropower

  6. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  7. Overload protection system for power inverter

    Science.gov (United States)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  8. Reliable Software Development for Machine Protection Systems

    CERN Document Server

    Anderson, D; Dragu, M; Fuchsberger, K; Garnier, JC; Gorzawski, AA; Koza, M; Krol, K; Misiowiec, K; Stamos, K; Zerlauth, M

    2014-01-01

    The Controls software for the Large Hadron Collider (LHC) at CERN, with more than 150 millions lines of code, resides amongst the largest known code bases in the world1. Industry has been applying Agile software engineering techniques for more than two decades now, and the advantages of these techniques can no longer be ignored to manage the code base for large projects within the accelerator community. Furthermore, CERN is a particular environment due to the high personnel turnover and manpower limitations, where applying Agile processes can improve both, the codebase management as well as its quality. This paper presents the successful application of the Agile software development process Scrum for machine protection systems at CERN, the quality standards and infrastructure introduced together with the Agile process as well as the challenges encountered to adapt it to the CERN environment.

  9. The international safeguards system and physical protection

    International Nuclear Information System (INIS)

    Canty, M.J.; Lauppe, W.D.; Richter, B.; Stein, G.

    1990-02-01

    The report summarizes and explains facts and aspects of the IAEA safeguards performed within the framework of the Non-Proliferation Treaty, and shows perspectives to be discussed by the NPT Review Conferences in 1990 and 1995. The technical background of potential misuse of nuclear materials for military purposes is explained in connection with the physical protection regime of the international safeguards, referring to recent developments for improvement of technical measures for material containment and surveillance. Most attention is given to the peaceful uses of nuclear energy and their surveillance by the IAEA safeguards, including such new technologies and applications as controlled nuclear fusion, laser techniques for uranium enrichment, and particle accelerators. The report's concluding analyses of the current situation show potentials for improvement and desirable or necessary consequences to be drawn for the international safeguards system, also taking into account recent discussions on the parliamentary level. (orig./HP) [de

  10. Passive Hearing Protection Systems and Their Performance

    National Research Council Canada - National Science Library

    McKinley, Richard; Bjorn, Valerie

    2005-01-01

    ... with personal hearing protection. This protection may be in the form of either an earplug that occludes the ear canal or a circumaural protector that inserts a barrier between the ambient noise and the ear...

  11. Modulation of LISA free-fall orbits due to the Earth-Moon system

    International Nuclear Information System (INIS)

    Cerdonio, Massimo; Marzari, Francesco; De Marchi, Fabrizio; De Pietri, Roberto; Jetzer, Philippe; Mazzolo, Giulio; Ortolan, Antonello; Sereno, Mauro

    2010-01-01

    We calculate the effect of the Earth-Moon (EM) system on the free-fall motion of LISA test masses. We show that the periodic gravitational pulling of the EM system induces a resonance with fundamental frequency 1 yr -1 and a series of periodic perturbations with frequencies equal to integer harmonics of the synodic month (≅ 3.92 x 10 -7 Hz). We then evaluate the effects of these perturbations (up to the 6th harmonics) on the relative motions between each test mass couple, finding that they range between 3 mm and 10 pm for the 2nd and 6th harmonic, respectively. If we take the LISA sensitivity curve, as extrapolated down to 10 -6 Hz in Bender (2003 Class. Quantum Grav. 20 301-10), we obtain that a few harmonics of the EM system can be detected in the Doppler data collected by the LISA space mission. This suggests that the EM system gravitational near field could provide an additional crosscheck to the calibration of LISA, as extended to such low frequencies.

  12. Establishing an Information Security System related to Physical Protection

    International Nuclear Information System (INIS)

    Jang, Sung Soon; Yoo, Ho Sik

    2009-01-01

    A physical protection system (PPS) integrates people, procedures and equipment for the protection of assets or facilities against theft, sabotage or other malevolent attacks. In the physical protection field, it is important the maintain confidentiality of PPS related information, such as the alarm system layout, detailed maps of buildings, and guard schedules. In this abstract, we suggest establishing a methodology for an information security system. The first step in this methodology is to determine the information to protect and possible adversaries. Next, system designers should draw all possible paths to the information and arrange appropriate protection elements. Finally he/she should analyze and upgrade their information security system

  13. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  14. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  15. 14 CFR 23.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 23.954... Fuel System § 23.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a...

  16. Application of data mining to the identification of critical factors in patient falls using a web-based reporting system.

    Science.gov (United States)

    Lee, Ting-Ting; Liu, Chieh-Yu; Kuo, Ya-Hui; Mills, Mary Etta; Fong, Jian-Guo; Hung, Cheyu

    2011-02-01

    The implementation of an information system has become a trend in healthcare institutions. How to identify variables related to patient safety among accumulated data has been viewed as a main issue. The purpose of this study was to identify critical factors related to patient falls through the application of data mining to available data through a hospital information system. Data on a total of 725 patient falls were obtained from a web-based nursing incident reporting system at a medical center in Taiwan. In the process of data mining, feature selection was applied as the first step, after which 10 critical factors were selected to predict the dependent variables (injury versus non-injury). An artificial neural network (ANN) analysis was applied to develop a predictive model and a multivariate stepwise logistic regression was performed for comparison purposes. The ANN model produced the following results: a Receiver-Operating-Character (ROC) curve indicated 77% accuracy, the positive predictive value (PPV) was 68%, and the negative predictive value (NPV) was 72%; while the multivariate stepwise logistic regression only identified 3 variables (fall assessment, anti-psychosis medication and diuretics) as significant predictors with ROC curve of 42%, PPV of 26.24%, and NPV of 87.12%. In addition to medication use such as anti-psychotic and diuretics, nursing intervention where a fall assessment is conducted could represent a critical factor related to outcomes of fall incidence. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  18. Thermal Management and Thermal Protection Systems

    Science.gov (United States)

    Hasnain, Aqib

    2016-01-01

    's rays directly impinging on the system. Heating rate of the lamps were calculated by knowing fraction of emitted energy in a wavelength interval and the filament temperature. This version of the model can be used to predict performance of the system under vacuum with extreme cold or hot conditions. Initial testing of the PTMS showed promise, and the thermal math model predicts even better performance in thermal vacuum testing. ii) Thermal Protection Systems (TPS) are required for vehicles which enter earth's atmosphere to protect from aerodynamic heating caused by the friction between the vehicle and atmospheric gases. Orion's heat shield design has two aspects which needed to be analyzed thermally: i) a small excess of adhesive used to bond the outer AVCOAT layer to the inner composite structure tends to seep from under the AVCOAT and form a small bead in between two bricks of AVCOAT, ii) a silicone rubber with different thermophysical properties than AVCOAT fills the gap between two bricks of AVCOAT. I created a thermal model using TD to determine temperature differences that are caused by these two features. To prevent false results, all TD models must be verified against something known. In this case, the TD model was correlated to CHAR, an ablation modelling software used to analyze TPS. Analyzing a node far from the concerning features, we saw that the TD model data match CHAR data, verifying the TD model. Next, the temperature of the silicone rubber as well as the bead of adhesive were analyzed to determine if they exceeded allowable temperatures. It was determined that these two features do not have a significant effect on the max temperature of the heat shield. This model can be modified to check temperatures at various locations of the heat shield where the composite thickness varies.

  19. DATA PROTECTION TECHNOLOGIES IN THE DISTANCE LEARNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna V. Herasymenko

    2015-06-01

    Full Text Available This article focuses on data protection in the support systems of distance learning. Different security tools such as hardware, software, transformation security and organizational protection are considered. There are analyzed key places that require protection and suggested possible options for their protection, such as the use of CAPTCHA for registration, protection for the IP-address and service of copy protection. Testing of the proposed security tools was piloted in terms of e-learning course "Information Technologies of Systems Analysis".

  20. 14 CFR 25.1093 - Induction system icing protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Induction System § 25.1093 Induction system icing protection. (a) Reciprocating engines. Each reciprocating engine air induction system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system icing protection. 25.1093...

  1. 14 CFR 29.1093 - Induction system icing protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1093 Induction system icing protection. (a) Reciprocating engines. Each reciprocating engine air induction system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system icing protection. 29.1093...

  2. 14 CFR 23.1093 - Induction system icing protection.

    Science.gov (United States)

    2010-01-01

    ... Induction System § 23.1093 Induction system icing protection. (a) Reciprocating engines. Each reciprocating engine air induction system must have means to prevent and eliminate icing. Unless this is done by other... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system icing protection. 23.1093...

  3. 14 CFR 27.1093 - Induction system icing protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Induction System § 27.1093 Induction system icing protection. (a) Reciprocating engines. Each reciprocating engine air induction system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system icing protection. 27.1093...

  4. Distributed Computation Environment Protection Based on Artificial Immune System Usage

    Directory of Open Access Journals (Sweden)

    Anton Andreevich Krasnopevtsev

    2013-02-01

    Full Text Available This article is devoted to a new approach to Grid-network protection against malware, based on artificial immune system usage. In the article possible Grid-network attacks, immune system coordinator architecture, immune system modules architecture, Grid-network system protection architecture are described.

  5. Over-voltage protection system and method

    Science.gov (United States)

    Chi, Song; Dong, Dong; Lai, Rixin

    2017-05-02

    An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diode indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.

  6. Specific features of modern voice protection systems

    Directory of Open Access Journals (Sweden)

    Roman A. Ustinov

    2017-11-01

    Full Text Available Nowadays, speech technologies are among the most vibrant sectors of the world’s economy. Of high importance is the problem of ensuring the security of speech information (SI. Here we discuss SI protection systems within a modern communication model. The model is multimodal, multithreaded, and implies a large number of subscribers interacting via several communication lines. With this in mind, we perform a detailed analysis of threats to the confidentiality, integrity and accessibility of SI. Existing methods of counteraction against these threats are discussed, and shown to be insufficient to ensure the safety of voice messages (VM in full. Mean while, there are new threats to the integrity and accessibility of SI, the solutions for which are either do not exist, or only being developed. We propose our original approach to counter these threats. Steganography methods are the most promising for ensuring the integrity of the VM.  In particular, using audiomarkers allows one to reliably trace speaker’sidentity throughout the entire communication session. In order to counter the threats to SI availability due to the capacity of the communication channel and the limited volumes of VM data storage, it is necessary to improve existing adaptive speech compression algorithms, along with developing new ones. Furthermore, such algorithms must keep the specified level of speech intelligibility.

  7. Evaluation of several corrosion protective coating systems on aluminum

    Science.gov (United States)

    Higgins, R. H.

    1981-01-01

    A study of several protective coating systems for use on aluminum in seawater/seacoast environments was conducted to review the developments made on protective coatings since early in the Space Shuttle program and to perform comparative studies on these coatings to determine their effectiveness for providing corrosion protection during exposure to seawater/seacoast environments. Panels of 2219-T87 aluminum were coated with 21 different systems and exposed to a 5 percent salt spray for 4000 hr. Application properties, adhesion measurements, heat resistance and corrosion protection were evaluated. For comparative studies, the presently specified Bostik epoxy system used on the SRB structures was included. Results of these tests indicate four systems with outstanding performance and four additional systems with protection almost as good. These systems are based on a chromated pretreatment, a chromate epoxy primer, and a polyurethane topcoat. Consideration for one of these systems should be included for those applications where superior corrosion protection for aluminum surfaces is required.

  8. Protected areas system planning and monitoring

    NARCIS (Netherlands)

    Vreugdenhil, D.

    2003-01-01

    The Vth World Parks Congress to be held in Durban, South Africa, September 8-17, 2003 will evaluate progress in protected areas conservation and stipulate strategic policies for the coming decade. Most countries of the world have at least a collection of protected areas, and have signed the

  9. Falls among union carpenters.

    Science.gov (United States)

    Lipscomb, Hester J; Li, Leiming; Dement, John M

    2003-08-01

    Falls are a leading cause of morbidity and mortality in the construction trades. We identified a cohort of 16,215 active union carpenters, hours worked, and their workers' compensation claims for a 10-year period. The data on this well-defined cohort were used to describe their work-related falls; to define rates of injury and the associated costs; and to identify high-risk groups. Same level falls occurred at a rate of 1.8/200,000 hours worked; falls from elevations at a rate of 2.3/200,000 hours worked. These injuries resulted in direct payments of 0.30 dollars per hour of work or 2.40 dollars per 8-hr day. Mean costs per fall increased with increasing age. Age was not associated with risk of falls from elevations; younger carpenters had modestly reduced rates of falls from the same level. Rates of falls decreased with increasing time in the union. Carpenters whose usual work involved drywall installation or residential work were at highest risk. Falls are a significant public health risk for carpenters and they are responsible for a significant burden of work-related injury costs. While there is a need for prevention of falls from elevations--through training, enforcement of fall protection regulations, improved safety climate, or engineering changes--there is also the need to prevent falls from lower elevations. Differences in risk likely reflect varying exposures and safety practices in different areas of carpentry, as well as training, experience, and job assignments based on longevity in the union. Copyright 2003 Wiley-Liss, Inc.

  10. Planetary Protection Considerations in EVA System Design

    Science.gov (United States)

    Eppler, Dean B.; Kosmo, Joseph J.

    2011-01-01

    very little expression of these anomalies. hardware from the human-occupied area may limit (although not likely eliminate) external materials in the human habitat. Definition of design-to requirements is critical to understanding technical feasibility and costs. The definition of Planetary Protection needs in relation to EVA mission and system element development cost impacts should be considered and interpreted in terms of Plausible Protection criteria. Since EVA operations will have the most direct physical interaction with the Martian surface, PP needs should be considered in the terms of mitigating hardware and operations impacts and costs.

  11. Decentralized Adaptive Overcurrent Protection for Medium Voltage Maritime Power Systems

    DEFF Research Database (Denmark)

    Ciontea, Catalin-Iosif; Bak, Claus Leth; Blaabjerg, Frede

    2016-01-01

    control unit. The new adaptive protection method is based on communication between the overcurrent relays and the equipment that could affect the protection system, such as circuit breakers and generators. Using PSCAD, the proposed method is implemented in a test medium voltage maritime power system......More and more maritime applications as marine vessels and offshore platforms need an adaptive protection power system. However, the adaptive protection is yet to be implemented in the maritime sector. Usually, the adaptive protection implies the existence of a central control unit that monitors...... the entire electrical network and changes the relay settings accordingly, but this approach is not adequate for the maritime power systems. This paper propose a decentralized adaptive protection method, where each protection relay is able to identify by itself the network status without the need of a central...

  12. Multiple corrosion protection systems for reinforced concrete bridge components.

    Science.gov (United States)

    2007-07-01

    Eleven systems combining epoxy-coated reinforcement with another corrosion protection system are evaluated using : the rapid macrocell, Southern Exposure, cracked beam, and linear polarization resistance tests. The systems include : bars that are pre...

  13. 76 FR 6119 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas...

    Science.gov (United States)

    2011-02-03

    ... Existing Marine Protected Areas to the National System of Marine Protected Areas and Updates to the List of National System Marine Protected Areas AGENCY: NOAA, Department of Commerce (DOC). ACTION: Public notice... protected area programs to join the National System of Marine Protected Areas and notice of updates to the...

  14. SNAP: a tool for nuclear physical protection system modeling

    International Nuclear Information System (INIS)

    Engi, D.; Grant, F.H. III.

    1979-10-01

    Nuclear safeguards systems are concerned, in part, with the physical protection of nuclear materials. The function of a physical protection system is to define the facility against adversary activities which could lead to theft of nuclear material or sabotage resulting in a radiological release. The Safeguards Network Analysis Procedure (SNAP) provides a convenient and standard analysis methodology for the evaluation of physical protection system analysis. This paper describes a detailed application of SNAP to a hypothetical nuclear facility

  15. Radiation protection system in Azerbaijan Republic

    International Nuclear Information System (INIS)

    Aliyev, L.

    2002-01-01

    land or merge into Caspian See. Is increased also the bring into country of instruments, equipments and other technical means, which work on radioactive sources basic. The numerated facts indicate that is necessary function of good radiation control land protection's system in Azerbaijan (sector radiation's investigations, Radioecology Center NMS of Ministry for Ecology and Natural Recourses the special Plant 'Isotope' and his burring point of radioactive wastes, Civil Defense. Academic organizations and NMS, execute monitoring, control and noticing function by radiation situation. The last two organizations structures, which have been occupied with keeping, transportation, disactivate and burring of radioactive sources and their wastes, which are receiving here from much institutions. The functional activity of special plant 'Isotope' must be reorganized and reconstruct- red the exist PBRW. There is necessity of build of new PBRW, in according with modern technical requirements to the industrial cycle on complete utilization of all radioactive wastes kinds. The monitoring function of radiation situation over all territory of Republic is put on NMS MENR of Azerbaijan. But, for the execution his problems, NMS are necessary new instrumental park (radiometric, dozemetric, spectrometric and etc.) and the dense monitoring network over all territory of Azerbaijan Republic. Co-operation with IAEA will allow improve the quality of radiation protection system of Azerbaijan in shorter periods. (author)

  16. A Cause-Consequence Chart of a Redundant Protection System

    DEFF Research Database (Denmark)

    Nielsen, Dan Sandvik; Platz, O.; Runge, B.

    1975-01-01

    A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy...

  17. 21 CFR 1240.86 - Protection of pier water system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Protection of pier water system. 1240.86 Section... DISEASES Source and Use of Potable Water § 1240.86 Protection of pier water system. No vessel engaged in interstate traffic shall make a connection between its nonpotable water system and any pier potable water...

  18. 14 CFR 29.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 29.954... lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a high probability of stroke...

  19. 14 CFR 27.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 27.954... lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a high probability of stroke...

  20. 14 CFR 25.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 25.954... lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a high probability of stroke...

  1. StreamNet Query System: Protected Areas

    Data.gov (United States)

    Pacific States Marine Fisheries Commission — Beginning in 1983, the Northwest Power Planning Council (Council) directed extensive studies of existing habitat and has analyzed alternative means of protection. In...

  2. Aerogel Modified Structural Thermal Protection System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This program will mature and further develop structural syntactic foam insulated integral Thermal Protection System (TPS) designs and materials as an enabling...

  3. Distributed Computations Environment Protection Using Artificial Immune Systems

    Directory of Open Access Journals (Sweden)

    A. V. Moiseev

    2011-12-01

    Full Text Available In this article the authors describe possibility of artificial immune systems applying for distributed computations environment protection from definite types of malicious impacts.

  4. Overvoltage protection system for wireless power transfer systems

    Energy Technology Data Exchange (ETDEWEB)

    Chambon, Paul H.; Jones, Perry T.; Miller, John M.; Onar, Omer C.; Tang, Lixin; White, Clifford P.

    2017-05-02

    A wireless power transfer overvoltage protection system is provided. The system includes a resonant receiving circuit. The resonant receiving circuit includes an inductor, a resonant capacitor and a first switching device. The first switching device is connected the ends of the inductor. The first switching device has a first state in which the ends of the inductor are electrically coupled to each other through the first switching device, and a second state in which the inductor and resonant capacitor are capable of resonating. The system further includes a control module configured to control the first switching device to switching between the first state and the second state when the resonant receiving circuit is charging a load and a preset condition is satisfied and otherwise, the first switching device is maintained in the first state.

  5. Distributed systems for the protection of nuclear stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-01-01

    The advantages of distributed control systems usually mentioned are improved exploitation, cost reduction, and adaptation to changes in technology. These advantages are obviously very interesting for nuclear power plant applications, and many such systems have been proposed. This note comments on the application of the distributed system concept to protection systems - what should be distributed - and closes with a brief description of a protection system based on microprocessors for pressurized water stations being built in France. (auth) [fr

  6. The concept of a marine Free-fall CPT systems revisited

    Science.gov (United States)

    Kopf, A.; Stegmann, S.

    2005-12-01

    Cone Penetration Tests (CPT) are a widely used method for the geotechnical in situ characterisation of sediments in onshore settings. In the course of enhanced use of the continental shelf and slope by humans impact, the need for time- and cost-efficient solutions in the marine realm is emerging. In order to avoid the challenges of lowering heavy gear to the seafloor for the penetration tests, free drop devices have been developed since the 1970s, however, the use of the majority of them was discontinued owing to technical difficulties in measurement and data interpretation caused by the impact. Based on those experiences, two different free-fall CPT lances were designed for the in situ measurement of strength (tip resistance, sleeve friction), pore pressure and temperature. In addition, deceleration and tilt are monitored for vertical profiling of the penetrated sediment column. Both CPT systems rely on an industry 15 cm2 piezocone with the sensors at the tip and a pressure housing containing a microprocessor at the top. The lightweight (40-100 kg), shallow water (200 m depth) lance works completely autonomous with a volatile memory and battery package, and can be deployed from any platform, even without a winch. The sturdier, deeper water (2500 m depth) system uses both power and telemetry for data transmission from the research vessel. The length and weight of either system can be varied according to the sediment stiffness and hence allow variable penetration depth (usually less than 5 m). Initial use of the CPT systems attests their efficiency and reliability in the measurement of sediment physical properties. While most of the data are collected within the first seconds of the CPT experiments, long term (pore pressure dissipation tests have also been successfully carried out for durations in excess of 6 hours. In a variety of estuarine and marine settings, our studies served objectives such as the assessment of slope stability, navigability of harbours

  7. Using a Medical Intranet of Things System to Prevent Bed Falls in an Acute Care Hospital: A Pilot Study.

    Science.gov (United States)

    Balaguera, Henri U; Wise, Diana; Ng, Chun Yin; Tso, Han-Wen; Chiang, Wan-Lin; Hutchinson, Aimee M; Galvin, Tracy; Hilborne, Lee; Hoffman, Cathy; Huang, Chi-Cheng; Wang, C Jason

    2017-05-04

    Hospitalized patients in the United States experience falls at a rate of 2.6 to 17.1 per 1000 patient-days, with the majority occurring when a patient is moving to, from, and around the bed. Each fall with injury costs an average of US $14,000. The aim was to conduct a technology evaluation, including feasibility, usability, and user experience, of a medical sensor-based Intranet of things (IoT) system in facilitating nursing response to bed exits in an acute care hospital. Patients 18 years and older with a Morse fall score of 45 or greater were recruited from a 35-bed medical-surgical ward in a 317-bed Massachusetts teaching hospital. Eligible patients were recruited between August 4, 2015 and July 31, 2016. Participants received a sensor pad placed between the top of their mattress and bed sheet. The sensor pad was positioned to monitor movement from patients' shoulders to their thighs. The SensableCare System was evaluated for monitoring patient movement and delivering timely alerts to nursing staff via mobile devices when there appeared to be a bed-exit attempt. Sensor pad data were collected automatically from the system. The primary outcomes included number of falls, time to turn off bed-exit alerts, and the number of attempted bed-exit events. Data on patient falls were collected by clinical research assistants and confirmed with the unit nurse manager. Explanatory variables included room locations (zones 1-3), day of the week, nursing shift, and Morse Fall Scale (ie, positive fall history, positive secondary diagnosis, positive ambulatory aid, weak impaired gait/transfer, positive IV/saline lock, mentally forgets limitations). We also assessed user experience via nurse focus groups. Qualitative data regarding staff interactions with the system were collected during two focus groups with 25 total nurses, each lasting approximately 1.5 hours. A total of 91 patients used the system for 234.0 patient-days and experienced no bed falls during the study period

  8. Using a Medical Intranet of Things System to Prevent Bed Falls in an Acute Care Hospital: A Pilot Study

    Science.gov (United States)

    Wise, Diana; Ng, Chun Yin; Tso, Han-Wen; Chiang, Wan-Lin; Hutchinson, Aimee M; Galvin, Tracy; Hilborne, Lee; Hoffman, Cathy; Huang, Chi-Cheng; Wang, C Jason

    2017-01-01

    Background Hospitalized patients in the United States experience falls at a rate of 2.6 to 17.1 per 1000 patient-days, with the majority occurring when a patient is moving to, from, and around the bed. Each fall with injury costs an average of US $14,000. Objective The aim was to conduct a technology evaluation, including feasibility, usability, and user experience, of a medical sensor-based Intranet of things (IoT) system in facilitating nursing response to bed exits in an acute care hospital. Methods Patients 18 years and older with a Morse fall score of 45 or greater were recruited from a 35-bed medical-surgical ward in a 317-bed Massachusetts teaching hospital. Eligible patients were recruited between August 4, 2015 and July 31, 2016. Participants received a sensor pad placed between the top of their mattress and bed sheet. The sensor pad was positioned to monitor movement from patients’ shoulders to their thighs. The SensableCare System was evaluated for monitoring patient movement and delivering timely alerts to nursing staff via mobile devices when there appeared to be a bed-exit attempt. Sensor pad data were collected automatically from the system. The primary outcomes included number of falls, time to turn off bed-exit alerts, and the number of attempted bed-exit events. Data on patient falls were collected by clinical research assistants and confirmed with the unit nurse manager. Explanatory variables included room locations (zones 1-3), day of the week, nursing shift, and Morse Fall Scale (ie, positive fall history, positive secondary diagnosis, positive ambulatory aid, weak impaired gait/transfer, positive IV/saline lock, mentally forgets limitations). We also assessed user experience via nurse focus groups. Qualitative data regarding staff interactions with the system were collected during two focus groups with 25 total nurses, each lasting approximately 1.5 hours. Results A total of 91 patients used the system for 234.0 patient-days and experienced

  9. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1976-01-01

    Reactor protection systems for nuclear power plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. The paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  10. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1977-01-01

    Reactor Protection Systems for Nuclear Power Plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. This paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  11. Seismic design criteria of fire protection systems for DOE facilities

    International Nuclear Information System (INIS)

    Hardy, G.; Cushing, R.; Driesen, G.

    1991-01-01

    Fire protection systems are critical to the safety of personnel and to the protection of inventory during any kind of emergency situation that involves a fire. The importance of these fire protection systems is hightened for DOE facilities which often house nuclear, chemical or scientific processes. Current research into the topic of open-quotes fires following earthquakesclose quotes has demonstrated that the risks of a fire starting as a result of a major earthquake can be significant. Thus, fire protection systems need to be designed to withstand the anticipated seismic event for the site in question

  12. Power supply devices and systems of relay protection

    CERN Document Server

    Gurevich, Vladimir

    2013-01-01

    Power Supply Devices and Systems of Relay Protection brings relay protection and electrical power engineers a single, concentrated source of information on auxiliary power supply systems and devices. The book also tackles specific problems and solutions of relay protection power supply systems and devices, which are often not dealt with in the literature. The author, an experienced engineer with more than 100 patents, draws on his own experience to offer practical, tested advice to readers. A Guide to Relay Protection Power Supply for Engineers and Technicians The first chapter reviews the ele

  13. Report on task I: fire protection system study

    International Nuclear Information System (INIS)

    Bernard, E.A.; Cano, G.L.

    1977-02-01

    This study (1) evaluates, on a comparative basis, the national and international regulatory and insurance standards that serve as guidance for fire protection within the nuclear power industry; (2) analyzes the recommendations contained in the major reports on the Browns Ferry Fire; (3) proposes quantitative safety goals and evaluation methods for Nuclear Power Plant Fire Protection Systems (NPPFPS); (4) identifies potential improvements that may be incorporated into NPPFPS; and (5) recommends a plan of action for continuation of the fire protections systems study

  14. 75 FR 81233 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2010-12-27

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department of... state and territorial marine protected area programs to join the National System of Marine Protected... territorial marine protected area (MPA) programs with potentially eligible existing MPAs to nominate their...

  15. Evolution of Radiation Protection System in Kenya

    International Nuclear Information System (INIS)

    Maina, J. A. W.

    2004-01-01

    Promulgation of radiation protection legislation in Kenya dates back to 1982, was revised in 1985 and became operational in 1986. This law, the Radiation Protection Act, establishes the Radiation Protection Board as the National Regulatory Authority, with an executive Inspectorate headed by the Secretary to the Board. Subsidiary legislation on radiological practices and standards were subsequently published. The Inspectorate carries out the National programme for notification, authorization, inspection and enforcement. Nuclear applications for peaceful purposes in Kenya are on the increase in all major fields of socio-economic development. Provision of regulatory services, guidance and enforcement procedures, has had a net growth over the last fifteen years. However, staff retention has been declining over the years in a market where job opportunities, with relatively high incentives, are high either inside or outside the country. Human and equipment resource development has therefore not kept pace and this has hampered effective and efficient provision of services. The poor status of the economy has had its impact on delivery of quality, effective and efficient radiation protection services. Provision of radiation services and acquisition of radiation detection and measurement equipment in the country has been generally lacking dating as far back as 1995. During the period 1989 to present, Kenya's Regulatory Authority, the Radiation Protection Board, undertook to provide personal monitoring, quality assurance, radioanalysis, and equipment calibration. Over the years these services have stalled due to outdated equipment most of which have broken down. A maintenance and calibration service for nuclear equipment is an expensive cross-boarder issue. Budgetary constraints, insufficient human and equipment resources, and a perennial 'brain drain' has placed limitations to the effectiveness and efficiency of implementation of the National programmes and slowed the

  16. Preparing the Machine Protection System for the 2011 run

    OpenAIRE

    Uythoven, J

    2011-01-01

    The expected performance of the Machine Protection System for 2011 is presented. An overview of the foreseen modifications to the machine protection system components during the Christmas stop and the required time for recommissioning is given. The possible impact of the MPS on the operational parameters of the LHC, like beam intensity, beta*, emittance and maximum beam energy, are discussed.

  17. 49 CFR 179.20 - Service equipment; protection systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Service equipment; protection systems. 179.20 Section 179.20 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... FOR TANK CARS General Design Requirements § 179.20 Service equipment; protection systems. If an...

  18. Impact of Y2K problem on physical protection system

    International Nuclear Information System (INIS)

    Kumar, R.; Swadia, N.S.; Zanwar, P.S.; Mishra, G.P.; Salunke, A.S.; Nigam, R.K.

    1999-01-01

    Year 2000 related system failures/problems in Physical Protection System pose no threat to general safety and functioning of any nuclear facility. But there can be potential security threats having radiation safety and non-proliferation concern and hence should be given due importance. Reviewing and testing Physical Protection System for Y2K compliance are easier than other systems as it does not directly affect operation of the plant. The existing emergency response capability at the nuclear facilities should be utilizes effectively to mitigate any Y2K induced events on Physical Protection System with dedicated manpower and channeled efforts

  19. Preventing falls

    Science.gov (United States)

    ... more difficult to stand up or keep your balance are a common cause of falls. Balance problems can also cause falls. When you walk, ... 2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing by ADAM ...

  20. The impact of industrial oil development on a protected area landscape: A case study on human population growth and landscape level change in Murchison Falls Conservation Area, Uganda.

    Science.gov (United States)

    Dowhaniuk, Nicholas; Hartter, Joel; Congalton, Russell G.; Palace, Michael W.; Ryan, Sadie J.

    2016-04-01

    Protected areas in Sub-Saharan Africa are sanctuaries for rich biodiversity and are important economic engines for African nations, but they are becoming increasingly threatened by discoveries of mineral deposits within and nearby their boundaries. In 2006, viable oil reserves were discovered in Murchison Falls Conservation Area (MFCA) in northern Uganda. Exploratory and appraisal activities concluded in 2014, and production is expected to begin in 2016. The oil development is associated with a substantial increase in human population outside MFCA, with people seeking jobs, land, and economic opportunity. Concomitant with this change is increased truck traffic, a sprawling and denser road network, and infrastructure within the park, which could have large impacts on both the flora and fauna. We examined the broader protected area landscape and the potential feedbacks from resource development on the ecosystem and local livelihoods. Our analysis combines a land cover analysis using Object Based Image Analysis of Landsat data (2002 and 2014), migration patterns and population change (1959-2014), and qualitative interview data. Our results suggest that most of the larger-scale impacts on the landscape and people are occurring in the western and northern sections, both inside and outside of the park. Additionally, oil development is not the only factor in the region influencing population growth and landscape change. Post conflict regrowth in the north, sugarcane production in the south, and migration to this region from conflict-ridden neighboring countries are also playing a vital role in human migration shaping the MFCA Landscape. Understanding the social and environmental changes and impacts in the MFCA and its surrounding areas will add to limited literature on the impacts of resource extraction on local, subsistence communities and landscape level change, which will be important as access and pressure for oil and minerals within protected areas continues to rise.

  1. System and method for quench protection of a superconductor

    Science.gov (United States)

    Huang, Xianrui; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas

    2008-03-11

    A system and method for protecting a superconductor from a quench condition. A quench protection system is provided to protect the superconductor from damage due to a quench condition. The quench protection system comprises a voltage detector operable to detect voltage across the superconductor. The system also comprises a frequency filter coupled to the voltage detector. The frequency filter is operable to couple voltage signals to a control circuit that are representative of a rise in superconductor voltage caused by a quench condition and to block voltage signals that are not. The system is operable to detect whether a quench condition exists in the superconductor based on the voltage signal received via the frequency filter and to initiate a protective action in response.

  2. Protection system proposed for the FED superconducting coils

    International Nuclear Information System (INIS)

    Bronner, G.; Gorker, G.E.; Murray, J.G.

    1981-01-01

    A failure modes study was the basis for establishing the protection system requirements and for identifying possible design alternatives or options that may be considered. Components of the protection system are discussed with respect to the redundancy and monitoring needed to assure high reliability, as measured by the probability that the system will respond when needed but will not respond inadvertently. High reliability is achieved by making the system fault tolerant using redundancy, decision logic, and computer monitoring

  3. Design and evaluation of physical protection systems of nuclear facilities

    International Nuclear Information System (INIS)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model

  4. 29 CFR 1926.502 - Fall protection systems criteria and practices.

    Science.gov (United States)

    2010-07-01

    ... a competent person to be undamaged and suitable for reuse. (20) The employer shall provide for...) from the unprotected or leading edge, except when erecting precast concrete members. (ii) When erecting precast concrete members, the control line shall be erected not less than 6 feet (1.8 m) nor more than 60...

  5. 49 CFR 214.105 - Fall protection systems standards and practices.

    Science.gov (United States)

    2010-10-01

    ... limits of the equipment, proper hook-up, anchoring and tie-off techniques, methods of use, and proper... repair, and at six-month intervals if left in one place. The drop-test shall consist of a 400-pound bag...

  6. Meteorite falls in Africa

    Science.gov (United States)

    Khiri, Fouad; Ibhi, Abderrahmane; Saint-Gerant, Thierry; Medjkane, Mohand; Ouknine, Lahcen

    2017-10-01

    The study of meteorites provides insight into the earliest history of our solar system. From 1800, about the year meteorites were first recognized as objects falling from the sky, until December 2014, 158 observed meteorite falls were recorded in Africa. Their collected mass ranges from 1.4 g to 175 kg with the 1-10 kg cases predominant. The average rate of African falls is low with only one fall recovery per 1.35-year time interval (or 0.023 per year per million km2). This African collection is dominated by ordinary chondrites (78%) just like in the worldwide falls. The seventeen achondrites include three Martian meteorite falls (Nakhla of Egypt, Tissint of Morocco and Zagami of Nigeria). Observed Iron meteorite falls are relatively rare and represent only 5%. The falls' rate in Africa is variable in time and in space. The number of falls continues to grow since 1860, 80% of which were recovered during the period between 1910 and 2014. Most of these documented meteorite falls have been recovered from North-Western Africa, Eastern Africa and Southern Africa. They are concentrated in countries which have a large surface area and a large population with a uniform distribution. Other factors are also favorable for observing and collecting meteorite falls across the African territory, such as: a genuine meteorite education, a semi-arid to arid climate (clear sky throughout the year most of the time), croplands or sparse grasslands and possible access to the fall location with a low percentage of forest cover and dense road network.

  7. Operational test report - Project W-320 cathodic protection systems

    International Nuclear Information System (INIS)

    Bowman, T.J.

    1998-01-01

    Washington Administrative Code (WAC) 173-303-640 specifies that corrosion protection must be designed into tank systems that treat or store dangerous wastes. Project W-320, Waste Retrieval Sluicing System (WRSS), utilizes underground encased waste transfer piping between tanks 241-C-106 and 241-AY-102. Corrosion protection is afforded to the encasements of the WRSS waste transfer piping through the application of earthen ionic currents onto the surface of the piping encasements. Cathodic protection is used in conjunction with the protective coatings that are applied upon the WRSS encasement piping. WRSS installed two new two rectifier systems (46 and 47) and modified one rectifier system (31). WAC 173-303-640 specifies that the proper operation of cathodic protection systems must be confirmed within six months after initial installation. The WRSS cathodic protection systems were energized to begin continuous operation on 5/5/98. Sixteen days after the initial steady-state start-up of the WRSS rectifier systems, the operational testing was accomplished with procedure OTP-320-006 Rev/Mod A-0. This operational test report documents the OTP-320-006 results and documents the results of configuration testing of integrated piping and rectifier systems associated with the W-320 cathodic protection systems

  8. Multicomponent Oxide Systems for Corrosion Protection.

    Science.gov (United States)

    1980-11-15

    both basic or acidic character. Such oxides are called amphoteric . The acid-base nature of an oxide is found to correlate reasonably well with the...basic and neutral media, whereas basic oxides will dissolve in acidic and neutral media. However, amphoteric oxi(es, although sparingly soluble in both...surfaces. In Table 1, it is shown that oxides such as A1203 and Cr20 3, which are generally thought of as protective, are in fact amphoteric , as would be

  9. Cloud-Based Smart Health Monitoring System for Automatic Cardiovascular and Fall Risk Assessment in Hypertensive Patients.

    Science.gov (United States)

    Melillo, P; Orrico, A; Scala, P; Crispino, F; Pecchia, L

    2015-10-01

    The aim of this paper is to describe the design and the preliminary validation of a platform developed to collect and automatically analyze biomedical signals for risk assessment of vascular events and falls in hypertensive patients. This m-health platform, based on cloud computing, was designed to be flexible, extensible, and transparent, and to provide proactive remote monitoring via data-mining functionalities. A retrospective study was conducted to train and test the platform. The developed system was able to predict a future vascular event within the next 12 months with an accuracy rate of 84 % and to identify fallers with an accuracy rate of 72 %. In an ongoing prospective trial, almost all the recruited patients accepted favorably the system with a limited rate of inadherences causing data losses (risk assessment of vascular events and falls.

  10. Discussion on several problems in evolution of radiation protection system

    International Nuclear Information System (INIS)

    Ziqiang, P.

    2004-01-01

    As viewed from the standpoint of radiation protection practice, it is necessary that the current system of radiological protection should be made more simple and coherent. The human-based protective measures alone are far from having met the requirements of environmental protection in many circumstances. Protecting the environment from ionising radiation would be implicated in radiation protection. Collective dose is an useful indicator, of which applicable extent should be defined. Using such an quantity could help improve radiation protection level, but applicable conditions should be indicated, temporal or spatial. Natural radiation is the largest contributor to the radiation exposure of human. Occupational exposure from natural radiation should be controlled, for occupations such as underground miners and air crew. Controlling both man-made and natural radiation exposure of pregnant women and children needs to be enhanced, especially radiological diagnosis and treatment. China radiation protection community, as a whole, is paying considerable attention to the ICRP's new Recommendations. Prof. Clarke's article 'A Report on Progress towards New Recommendations', a communication from the International Commission on Radiological Protection, has been translated into Chinese and published on Radiation Protection, the Official Journal of China Radiation Protection Society with a view of intensifying awareness of the new Recommendations within more radiation protection workers and people concerned. In addition, a special meeting was convened in early 2002 to address the comments on the new Recommendations. (author)

  11. New measuring and protection system at VR-1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Jurickova, M.

    2006-01-01

    The contribution describes the new measuring and protection system of the VR-1 training reactor. The measuring and protection system upgrade is an integral part of the reactor I and C upgrade. The new measuring and protection system of the VR-1 reactor consists of the operational power measuring and the independent power protection systems. Both systems measure the reactor power and power rate, initiate safety action if safety limits are exceeded and send data (power, power rate, status, etc.) to the reactor control system. The operational power measuring system is a full power range system that receives signal from a fission chamber. The signal is evaluated according to the reactor power either in the pulse or current mode. The current mode utilizes the DC current and Campbell techniques. The new independent power protection system operates in the two highest reactor power decades. It receives signals from a boron chamber and evaluates it in the pulse mode. Both systems are computer based. The operational power measuring and independent power protection systems are diverse - different types and location of chambers, completely different hardware, software algorithms for the power and power rate calculations, software development tools and teems for the software manufacturing. (author)

  12. Architecture and Fault Identification of Wide-area Protection System

    Directory of Open Access Journals (Sweden)

    Yuxue Wang

    2012-09-01

    Full Text Available Wide-area protection system (WAPS is widely studied for the purpose of improvng the performance of conventional backup protection. In this paper, the system architecture of WAPS is proposed and its key technologies are discussed in view of engineering projects. So a mixed structurecentralized-distributed structure which is more suitable for WAPS in limited power grid region, is obtained based on the advantages of the centralized structure and distributed structure. Furthermore, regional distance protection algorithm was taken as an example to illustrate the functions of the constituent units. Faulted components can be detected based on multi-source imformation fuse in the algorithm. And the algorithm cannot only improve the selectivity, the rapidity, and the reliability of relaying protection but also has high fault tolerant capability. A simulation of 220 kV grid systems in Easter Hubei province shows the effectiveness of the wide-area protection system presented by this paper.

  13. Discussion on some problems in evolution of radiation protection system

    International Nuclear Information System (INIS)

    Pan Ziqiang

    2003-01-01

    In radiation protection practice in China, the appropriate simplification and better coordination for the existing radiation protection system are necessary. The human-based protective measures alone could not meet the requirements of the environmental protection in many circumstances. Protecting the environment from ionizing radiation would be implicated in radiation protection. Collective dose is an useful index, its applicable scope should be well defined. Using such an quantity can help increase radiation protection level, but applicable conditions should be defined, such as time and space. Natural radiation is the largest contributor of the radiation exposure to human. Occupational exposure from natural radiation should be controlled, such as to underground miners and air crew. Controlling both man-made and natural radiation exposure to pregnant women and children needs to be enhanced, especially radiological diagnosis and therapy

  14. Exploring user experience and technology acceptance for a fall prevention system: results from a randomized clinical trial and a living lab.

    Science.gov (United States)

    Vaziri, Daryoush D; Aal, Konstantin; Ogonowski, Corinna; Von Rekowski, Thomas; Kroll, Michael; Marston, Hannah R; Poveda, Rakel; Gschwind, Yves J; Delbaere, Kim; Wieching, Rainer; Wulf, Volker

    2016-01-01

    Falls are common in older adults and can result in serious injuries. Due to demographic changes, falls and related healthcare costs are likely to increase over the next years. Participation and motivation of older adults in fall prevention measures remain a challenge. The iStoppFalls project developed an information and communication technology (ICT)-based system for older adults to use at home in order to reduce common fall risk factors such as impaired balance and muscle weakness. The system aims at increasing older adults' motivation to participate in ICT-based fall prevention measures. This article reports on usability, user-experience and user-acceptance aspects affecting the use of the iStoppFalls system by older adults. In the course of a 16-week international multicenter study, 153 community-dwelling older adults aged 65+ participated in the iStoppFalls randomized controlled trial, of which half used the system in their home to exercise and assess their risk of falling. During the study, 60 participants completed questionnaires regarding the usability, user experience and user acceptance of the iStoppFalls system. Usability was measured with the System Usability Scale (SUS). For user experience the Physical Activity Enjoyment Scale (PACES) was applied. User acceptance was assessed with the Dynamic Acceptance Model for the Re-evaluation of Technologies (DART). To collect more detailed data on usability, user experience and user acceptance, additional qualitative interviews and observations were conducted with participants. Participants evaluated the usability of the system with an overall score of 62 (Standard Deviation, SD 15.58) out of 100, which suggests good usability. Most users enjoyed the iStoppFalls games and assessments, as shown by the overall PACES score of 31 (SD 8.03). With a score of 0.87 (SD 0.26), user acceptance results showed that participants accepted the iStoppFalls system for use in their own home. Interview data suggested that certain

  15. Design principles for radiological protection instrumentation systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1981-02-01

    This Code of Practice takes the form of recommendations intended for designers and installers of Radiological Protection Instrumentation, and should also be of value to the newcomer to the R.P.I. field. Topics are discussed under the following headings: outline of R.P.I. requirements, specifying the requirement, satisfying the requirements, (overall design, availability and reliability, information display, human factors, power supplies, manufacture, quality assurance, testing, and cost analysis), supply, location and operation of the equipment, importance of documentation. (U.K.)

  16. Annexes to the lecture on reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The present paper deals with the fundamentals for a reactor protection system and discusses the following topics: - System lay-out - Analog measured data acquisition - Analog measured data processing - Limit value generation and logical gating - Procesing of the reactor protection actuation signals - Decoupling of the reactor protection system - Mechanical lay-out - Monitoring system and - Emergency control station. (orig./RW)

  17. NSTX-U Digital Coil Protection System Software Detailed Design

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-06-01

    The National Spherical Torus Experiment (NSTX) currently uses a collection of analog signal processing solutions for coil protection. Part of the NSTX Upgrade (NSTX-U) entails replacing these analog systems with a software solution running on a conventional computing platform. The new Digital Coil Protection System (DCPS) will replace the old systems entirely, while also providing an extensible framework that allows adding new functionality as desired.

  18. Rise, Fall, and Semiperipheral Development in the Andean World-System

    Directory of Open Access Journals (Sweden)

    Darrell LaLone

    2015-08-01

    Full Text Available This paper examines how different power strategies have been playedover the course of the three-thousand year Andean civilization. In broad terms, the power strategies center on ideological, economic, and military power (Mann 1986; Earle 1997. The case materials show that what we call “states” are formations that succeed, albeit temporarily, in combining strat-egies of ideological, economic, and military power. Nonetheless, following Randall Collins (1981:71, I would argue that coercive power is the sine qua non for state development. If we start from the power to coerce as a foun-dation, varying strategies of manipulating economic, ideological, and military power will produce a number of different pathways to varying forms of organization. Some may be more centralized than others, some may be less steeply strati?ed than others, some may have more specialized institutions than others, some may look more like environmental management systems, and others may look more like well-organized predatory protection rackets. Those which were less successful in manipulating these strategies were more vulnerable to collapse, opening the way for new formations to emerge. As world-systems approaches would predict, this has often happened on the peripheries of former core formations.

  19. Systems for protection and automation of distribution electric networks 22 kv

    International Nuclear Information System (INIS)

    Horak, M.

    2012-01-01

    This article deals with the new concept of fault location in overhead and cable 22 kV distribution systems, which are operated by ZSE Distribucia, a.s.. In the past the localisation of faults was a demanding and lengthy procedure, because the electric protection indicated only the affected output feeder. The exact fault point was then localised by manipulation in the field and by test switching in the power line where the fault took place. The current development of electric facilities and sharp fall in prices give use the possibility to broadly apply the simple digital metering devices equipped with the electric protection function. Once these devices are positioned densely along the individual power lines of the network, it is possible to localise the failure position quite exactly and electricity supply can be quickly restored. (Authors)

  20. Flexible Foam Protection Materials for Portable Life Support System Packaging Study

    Science.gov (United States)

    Tang,Henry H.; Dillon, Paul A.; Thomas, Gretchen A.

    2009-01-01

    This paper discusses the phase I effort in evaluating and selecting a light weight impact protection material for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS) conceptual packaging study. A light weight material capable of holding and protecting the components inside the PLSS is required to demonstrate the viability of the flexible PLSS packaging concept. The material needs to distribute, dissipate, and absorb the impact energy of the PLSS falling on the lunar surface. It must also be robust to consistently perform over several Extravehicular Activity (EVA) missions in the extreme lunar thermal vacuum environment. This paper documents the performance requirements for selecting a foam protection material, and the methodologies for evaluating some commercial off-the-shelf (COTS) foam material candidates. It also presents the mechanical properties and impact drop tests results of the foam material candidates. The results of this study suggest that a foam based flexible protection system is a viable solution for PLSS packaging. However, additional works are needed to optimize COTS foam or to develop a composite foam system that will meet all the performance requirements for the CSSE PLSS flexible packaging.

  1. Criminal law repercussions on the Civil Protection System

    Science.gov (United States)

    Altamura, M.; Musso, L.

    2009-09-01

    The legal systems of our Countries provide the citizenship with a high level of protection. Personal safety and the protection of property are guaranteed by the State through organized structures among which we can include the Civil Protection. The progress of science and technology has greatly improved monitoring tools, currently used by the Civil Protection, which allow, to a certain extent, to predict and prevent risk and natural hazards. The assertion of an individual right, which in some cases has reached a constitutional rank, to benefit from Civil Protection services and the widespread perception throughout the citizenship of the competence of the system to prevent disasters, often causes people to take legal action against Civil Protection authorities should they fail in their duties to protect. However, the attempt of having both recognized an economic compensation for the suffered loss and the punishment of those whom misled, frequently undergoes criminal law. This process could have results that may jeopardize the effectiveness of Civil Protection service without meeting citizens’ demands. A dual effort is thus necessary in order to solve such a problem. On the one hand, an interdisciplinary knowledge needs to pervade criminal law in an attempt to relieve its self-referentiality and pretended supremacy. On the other hand an alternative, and more agile, system -such as civil or administrative law- has to be identified in order to respond to the legitimate requests for protection in the case of a faulty behaviour of the authorities.

  2. Impacts of the Columbia River hydroelectric system on main-stem habitats of fall chinook salmon

    Science.gov (United States)

    Dauble, D.D.; Hanrahan, T.P.; Geist, D.R.; Parsley, M.J.

    2003-01-01

    Salmonid habitats in main-stem reaches of the Columbia and Snake rivers have changed dramatically during the past 60 years because of hydroelectric development and operation. Only about 13% and 58% of riverine habitats in the Columbia and Snake rivers, respectively, remain. Most riverine habitat is found in the upper Snake River; however, it is upstream of Hells Canyon Dam and not accessible to anadromous salmonids. We determined that approximately 661 and 805 km of the Columbia and Snake rivers, respectively, were once used by fall chinook salmon Oncorhynchus tshawytscha for spawning. Fall chinook salmon currently use only about 85 km of the main-stem Columbia River and 163 km of the main-stem Snake River for spawning. We used a geomorphic model to identify three river reaches downstream of present migration barriers with high potential for restoration of riverine processes: the Columbia River upstream of John Day Dam, the Columbia-Snake-Yakima River confluence, and the lower Snake River upstream of Little Goose Dam. Our analysis substantiated the assertion that historic spawning areas for fall chinook salmon occurred primarily within wide alluvial floodplains, which were once common in the mainstem Columbia and Snake rivers. These areas possessed more unconsolidated sediment and more bars and islands and had lower water surface slopes than did less extensively used areas. Because flows in the main stem are now highly regulated, the predevelopment alluvial river ecosystem is not expected to be restored simply by operational modification of one or more dams. Establishing more normative flow regimes - specifically, sustained peak flows for scouring - is essential to restoring the functional characteristics of existing, altered habitats. Restoring production of fall chinook salmon to any of these reaches also requires that population genetics and viability of potential seed populations (i.e., from tributaries, tailrace spawning areas, and hatcheries) be considered.

  3. 78 FR 30870 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2013-05-23

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: National Marine Protected...) invited federal, state, commonwealth, and territorial marine protected area (MPA) programs with... of Marine Protected Areas of the United States (Framework), developed in response to Executive Order...

  4. Discussion on radiation protection system from ethical issues

    International Nuclear Information System (INIS)

    Li, Xutong; Guo, Qiuju

    2002-01-01

    This paper discussed the relationship between radiation protection system and ethical principle, viz. equity and efficiency. According to the authors' opinions, the main problem that the system of radiation protection facing now is the dose-limitation principle cannot incarnate the equity principle completely. Even though the distinguishing between practice and intervention is no other than solving the problem, but the scheme is not perfect still. Ethical issues should be given more attention and be more researched when we try to modify the radiation protection system today

  5. Foundations for Protecting Renewable-Rich Distribution Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brahma, Sukumar [New Mexico State Univ., Las Cruces, NM (United States); Ranade, Satish [New Mexico State Univ., Las Cruces, NM (United States)

    2016-11-01

    High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid introduces new challenges to protection of such systems. This is because the existing protection systems are designed with two assumptions: 1) system is single-sourced, resulting in unidirectional fault current, and (2) fault currents are easily detectable due to much higher magnitudes compared to load currents. Due to the fact that most renewables interface with the grid though inverters, and inverters restrict their current output to levels close to the full load currents, both these assumptions are no longer valid - the system becomes multi-sourced, and overcurrent-based protection does not work. The primary scope of this study is to analyze the response of a grid-tied inverter to different faults in the grid, leading to new guidelines on protecting renewable-rich distribution systems.

  6. The Dutch system of legal protection in public procurement procedures

    NARCIS (Netherlands)

    van Heeswijck, Arthur

    2015-01-01

    The legal protection of entrepreneurs in public procurement procedures has been a point of concern to the European Union legislator, leading to the adoption of well-known the Remedies Directives. This article examines the conformity of the Dutch system of judicial protection in the procurement field

  7. 49 CFR 179.18 - Thermal protection systems.

    Science.gov (United States)

    2010-10-01

    ..., underframes, metal jackets, insulation, and thermal protection. A complete record of each analysis shall be... 49 Transportation 2 2010-10-01 2010-10-01 false Thermal protection systems. 179.18 Section 179.18 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY...

  8. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  9. Centralized Coordination of Load Shedding & Protection System of Transmission Lines

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2018-01-01

    The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized......, over current protection....

  10. Selectivity of power system protections at power swings in power system

    Directory of Open Access Journals (Sweden)

    Jan Machowski

    2012-12-01

    Full Text Available The paper discusses out-of-step protection systems such as: generator pole slip protections, out of step tripping protections, distance protections of step-up transformer, distance protections of transmission lines and transformers, power swing blocking, and special out-of-step protection. It is shown that all these protections make up a protection system, to which a setting concept uniform for the entire power system has to be applied. If a power system is inappropriately equipped with these protections, or their settings are inappropriate, they may operate unselectively, thus contributing to the development of power system blackouts. In the paper the concepts for a real power system are given for the two stages: target stage fully compliant with selectivity criteria, and transitional stage between the current and target stages.

  11. Adaptive Overcurrent Protection for Microgrids in Extensive Distribution Systems

    DEFF Research Database (Denmark)

    Lin, Hengwei; Guerrero, Josep M.; Jia, Chenxi

    2016-01-01

    Microgrid is regarded as a new form to integrate the increasing penetration of distributed generation units (DGs) in the extensive distribution systems. This paper proposes an adaptive overcurrent protection strategy for a microgrid network. The protection coordination of the overcurrent relays...... measurements in another neural network model. Reconfigurations can be performed to modify the settings of the on-field relays to enhance the reliable operation for the different operational situations. The test results show that the adaptive overcurrent protection scheme with the assistance of estimation model...... can modify the protective settings for the new operation state accurately and intelligently....

  12. 76 FR 82277 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2011-12-30

    ... Existing Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department... received from federal, state, territorial and tribal marine protected area programs to join the National System of Marine Protected Areas. SUMMARY: In July 2011, NOAA and the Department of the Interior (DOI...

  13. 75 FR 972 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2010-01-07

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department of... Federal, State and territorial marine protected area programs to join the National System of Marine Protected Areas. SUMMARY: NOAA and the Department of the Interior (DOI) invited Federal, State, commonwealth...

  14. Understanding of radiation protection in medicine. Pt. 2. Occupational exposure and system of radiation protection

    International Nuclear Information System (INIS)

    Iida, Hiroji; Yamamoto, Tomoyuki; Shimada, Yasuhiro

    1997-01-01

    Using a questionnaire we investigated whether radiation protection is correctly understood by medical doctors (n=140) and nurses (n=496). Although medical exposure is usually understood by medical doctors and dentists, their knowledge was found to be insufficient. Sixty-eight percent of medical doctors and 50% of dentists did not know about the system of radiation protection. Dose monitoring was not correctly carried out by approximately 20% of medical staff members, and medical personnel generally complained of anxiety about occupational exposure rather than medical exposure. They did not receive sufficient education on radiation exposure and protection in school. In conclusion, the results of this questionnaire suggested that they do not have adequate knowledge about radiation exposure and protection. The lack of knowledge about protection results in anxiety about exposure. To protect oneself from occupational exposure, individual radiation doses must be monitored, and medical practice should be reconsidered based on the results of monitoring. To eliminate unnecessary medical and occupational exposure and to justify practices such as radiological examinations, radiation protection should be well understood and appropriately carried out by medical doctors and dentists. Therefore, the education of medical students on the subject of radiation protection is required as is postgraduate education for medical doctors, dentists and nurses. (author)

  15. Decarbonization of the German energy system due to falling or rising power consumption?

    International Nuclear Information System (INIS)

    Guminski, Andrej; Roon, Serafin von

    2016-01-01

    Since the publication of the draft ''Climate Protection Plan 2050'' and the ''Green Paper on Energy Efficiency'', it is clear that the Federal Government is focusing on the electrification of the heat and transport sector in order to increase the share of renewable energies in these sectors. This step is not uncontroversial, and represents a paradigm shift in science and politics, because the reduction of the cross electricity consumption move into the background. It is now necessary to clearly distinguish between the conventional power consumption, which must continue to be tested for energy savings and efficiency potential, and the new power consumption, here referred to as the coupling current, which is accepted in order to achieve the objectives of the energy transition. Since the consideration of the energy transition as a purely national project is too short, possible positive and negative effects of the European Union Emission Trading System (EU ETS) deserve particular attention with regard to this reorientation. [de

  16. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1976-01-01

    A control system is described which is comprised of a plurality of low worth absorber elements with individual hydraulic actuator assemblies, positioned within the reactor vessel. Axial distortions and safety hazards are minimized by this arrangement. (E.C.B.)

  17. Penetration testing protecting networks and systems

    CERN Document Server

    Henry, Kevin M

    2012-01-01

    This book is a preparation guide for the CPTE examination, yet is also a general reference for experienced penetration testers, ethical hackers, auditors, security personnel and anyone else involved in the security of an organization's computer systems.

  18. Computer-aided protective system (CAPS)

    International Nuclear Information System (INIS)

    Squire, R.K.

    1988-01-01

    A method of improving the security of materials in transit is described. The system provides a continuously monitored position location system for the transport vehicle, an internal computer-based geographic delimiter that makes continuous comparisons of actual positions with the preplanned routing and schedule, and a tamper detection/reaction system. The position comparison is utilized to institute preprogrammed reactive measures if the carrier is taken off course or schedule, penetrated, or otherwise interfered with. The geographic locater could be an independent internal platform or an external signal-dependent system utilizing GPS, Loran or similar source of geographic information; a small (micro) computer could provide adequate memory and computational capacity; the insurance of integrity of the system indicates the need for a tamper-proof container and built-in intrusion sensors. A variant of the system could provide real-time transmission of the vehicle position and condition to a central control point for; such transmission could be encrypted to preclude spoofing

  19. NDE for Ablative Thermal Protection Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This program addresses the need for non-destructive evaluation (NDE) methods for quality assessment and defect evaluation of thermal protection systems (TPS),...

  20. NDE for Ablative Thermal Protection Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This program addresses the need for non-destructive evaluation (NDE) methods for quality assessment and defect evaluation of thermal protection systems (TPS). Novel...

  1. Thermal Protection System Materials (TPSM): 3D MAT

    Data.gov (United States)

    National Aeronautics and Space Administration — The 3D MAT Project seeks to design and develop a game changing Woven Thermal Protection System (TPS) technology tailored to meet the needs of the Orion Multi-Purpose...

  2. Monitoring, control and protection of interconnected power systems

    CERN Document Server

    Häger, Ulf; Voropai, Nikolai

    2014-01-01

    This book presents new tools and methods for monitoring, control and protection of large scale power systems, adapting Smart Grid technologies based on wide area data exchange in combination with modern measurement devices and advanced network controllers.

  3. Kinetic Integrated Thermal Protection System (KnITPS)

    Data.gov (United States)

    National Aeronautics and Space Administration — Use the flexibility and shape formation possibilities inherent in knitting to form thermal protection systems that can be custom fitted to a heat shield carrier...

  4. Short circuit protection for a power distribution system

    Science.gov (United States)

    Owen, J. R., III

    1969-01-01

    Sensing circuit detects when the output from a matrix is present and when it should be present. The circuit provides short circuit protection for a power distribution system where the selection of the driven load is accomplished by digital logic.

  5. CNSS: Interagency Partnering to Protect Our National Security Systems

    National Research Council Canada - National Science Library

    Grimes, John G

    2008-01-01

    .... The CNSS performs the vital function of mobilizing the full, interagency National Security Community for the protection of telecommunications and information systems that support U.S. national security...

  6. Relation between Hagberg-Perten falling number and acidity of wheat flour according to storage and agricultural systems

    Directory of Open Access Journals (Sweden)

    Petrenko Vasyl

    2015-01-01

    Full Text Available Wheat flour samples from three agricultural systems and two storage modes were evaluated and compared in dynamics of their titratable acidity and Falling number by Hagberg-Perten method during one year storage and their interaction. The obtained results indicate strong relationships between increasing acidity and lowering α-amylase activity using samples after biological, ecological agriculture systems and dry storage mode (without temperature control. On the other hand, intensive agriculture and cool storing (T +6±2ºS provided independent change in those indices and better technological properties for the end of the storage period.

  7. Protection of Distribution Systems with Distributed Energy Resources

    DEFF Research Database (Denmark)

    Bak-Jensen, Birgitte; Browne, Matthew; Calone, Roberto

    of 17 months of work of the Joint Working Group B5/C6.26/CIRED “Protection of Distribution Systems with Distributed Energy Resources”. The working group used the CIGRE report TB421 “The impact of Renewable Energy Sources and Distributed Generation on Substation Protection and Automation”, published......The usage of Distributed Energy Resources (DER) in utilities around the world is expected to increase significantly. The existing distribution systems have been generally designed for unidirectional power flow, and feeders are opened and locked out for any fault within. However, in the future...... by WG B5.34 as the entry document for the work on this report. In doing so, the group aligned the content and the scope of this report, the network structures considered, possible islanding, standardized communication and adaptive protection, interface protection, connection schemes and protection...

  8. Fall prevention walker during rehabilitation

    Science.gov (United States)

    Tee, Kian Sek; E, Chun Zhi; Saim, Hashim; Zakaria, Wan Nurshazwani Wan; Khialdin, Safinaz Binti Mohd; Isa, Hazlita; Awad, M. I.; Soon, Chin Fhong

    2017-09-01

    This paper proposes on the design of a walker for the prevention of falling among elderlies or patients during rehabilitation whenever they use a walker to assist them. Fall happens due to impaired balance or gait problem. The assistive device is designed by applying stability concept and an accelerometric fall detection system is included. The accelerometric fall detection system acts as an alerting device that acquires body accelerometric data and detect fall. Recorded accelerometric data could be useful for further assessment. Structural strength of the walker was verified via iterations of simulation using finite element analysis, before being fabricated. Experiments were conducted to identify the fall patterns using accelerometric data. The design process and detection of fall pattern demonstrates the design of a walker that could support the user without fail and alerts the helper, thus salvaging the users from injuries due to fall and unattended situation.

  9. Architecture and Fault Identification of Wide-area Protection System

    OpenAIRE

    Yuxue Wang; Xianggen Yin; Zhe Zhang; Zhenxing Li

    2012-01-01

    Wide-area protection system (WAPS) is widely studied for the purpose of improvng the performance of conventional backup protection. In this paper, the system architecture of WAPS is proposed and its key technologies are discussed in view of engineering projects. So a mixed structure—centralized-distributed structure which is more suitable for WAPS in limited power grid region, is obtained based on the advantages of the centralized structure and distributed structure. Furthermore, regional dis...

  10. Relay protection coordination with generator capability curve, excitation system limiters and power system relay protections settings

    OpenAIRE

    Buha Danilo; Buha Boško; Jačić Dušan; Gligorov Saša; Božilov Marko; Marinković Savo; Milosavljević Srđan

    2016-01-01

    The relay protection settings performed in the largest thermal powerplant (TE "Nikola Tesla B") are reffered and explained in this paper. The first calculation step is related to the coordination of the maximum stator current limiter settings, the overcurrent protection with inverse characteristics settings and the permitted overload of the generator stator B1. In the second calculation step the settings of impedance generator protection are determined, and the methods and criteria according ...

  11. System Protection Schemes in Eastern Denmark

    DEFF Research Database (Denmark)

    Rasmussen, Joana

    etc. Stigsnæs power plant could possibly improve the reactive power support in emergency situations, as it is the closest power plant in the southern part of the system. In general, rescheduling power plants and voltage regulation at remote generators (MVAr adjustment) are not considered the most......% of the wind generation capacity in Eastern Denmark. The restricted reactive power transfer from the 132-kV main system is the key indicator of voltage instability. The high load situation with high wind generation is considered a worst-case scenario in relation to serious problems with reactive power. Line...... Units placed at strategic points are evaluated as an efficient tool for power system monitoring of important 400 kV and 132 kV transmission corridors in Eastern Denmark. The first PMU is connected to a 400 kV bus near Asnæs power plant, the largest generating unit in Eastern Denmark. The PMU in Radsted...

  12. The Philosophy of the New Radiation Protection System

    International Nuclear Information System (INIS)

    Wikman, P.

    2004-01-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle I f the individual is sufficiently protected from a source, then society is also protected from that source . This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs

  13. 14 CFR 25.1316 - System lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false System lightning protection. 25.1316... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1316 System lightning... systems to perform these functions are not adversely affected when the airplane is exposed to lightning...

  14. Fire protection in ventilation systems and in case of fire operating ventilation systems

    International Nuclear Information System (INIS)

    Zitzelsberger, J.

    1983-01-01

    The fire risks in ventilation systems are discussed. It follows a survey of regulations on fire prevention and fire protection in ventilation systems and smoke and heat exhaust systems applicable to nuclear installations in the Federal Republic of Germany. Fire protection concepts for normal systems and for systems operating also in case of fire will be given. Several structural elements for fire protection in those systems will be illustrated with regard to recent research findings

  15. ELECTRONIC PAYMENT SYSTEM AND ITS PROTECTION

    Directory of Open Access Journals (Sweden)

    Miroslav Milutinovic

    2015-01-01

    Full Text Available All developed countries are in transition from the IT economy to a web economy - the biggest technological innovation that will have a long-term positive effect on the formation of the economic growth rate, the major structural changes and on the differentiated effects on the economic areas that are, at a faster or a slower rate, being included in this technological change. The electronic commerce or e-commerce has a huge potential for development. The electronic commerce between the companies (B-2-B is significantly greater compared to retail electronic commerce (B-2-C. In both spheres of trade, the Internet is used as a platform for the transfer of information and for concluding business deals. Market economy requires Accelerated Payment Processing which is achieved by introducing and improving the electronic payment procedures. There is an emphasized dichotomy between the two spheres of the payment system: large-value and small-value payments. The large value payment systems can be described as the arteries of the payment system, and the small-value transfer systems as a complex network of veins that bind the entire economy.

  16. Lightning protecting materials used on radar system

    NARCIS (Netherlands)

    Blaj, M.A.; Damstra, Geert C.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2009-01-01

    Because of the extensive use in modern systems of very sensitive electronic components, lightning strikes does not represent only a threat, but something that cannot be neglected anymore and safety hazards caused by direct and indirect lightning to the aircraft or naval industry. Everyday new

  17. New Protective Measures for Cooling Systems

    International Nuclear Information System (INIS)

    Carter, D. Anthony; Nonohue, Jonh M.

    1974-01-01

    Cooling water treatments have been updated and improved during the last few years. Particularly important are the nontoxic programs which conform plant cooling water effluents to local water quality standards without expenditures for capital equipment. The relationship between scaling and corrosion in natural waters has been recognized for many years. This relationship is the basis for the Langelier Saturation Index control method which was once widely applied to reduce corrosion in cooling water systems. It used solubility characteristics to maintain a very thin deposit on metal surfaces for preventing corrosion. This technique was rarely successful. That is, the solubility of calcium carbonate and most other inorganic salts depends on temperature. If good control exists on cold surfaces, excessive deposition results on the heat transfer tubes. Also, because water characteristic normally vary in a typical cooling system, precise control of scaling at both hot and cold surfaces is virtually impossible

  18. Implementation of FPGA-Based Diverse Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min [KEPCO Engineering and Construction Company Inc., Daejeon (Korea, Republic of)

    2015-10-15

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails.

  19. The Protective Arm of the Renin Angiotensin System (RAS)

    DEFF Research Database (Denmark)

    will become of major medical importance in the near future. Focusing on recent research, The Protective Arm of the Renin Angiotensin System presents a host of new experimental studies on specific components of the RAS, namely angiotensin AT2 receptors (AT2R), the angiotensin (1-7) peptide with its receptor...... understanding of the protective side of the Renin Angiotensin System (RAS) involving angiotensin AT2 receptor, ACE2, and Ang(1-7)/Mas receptor Combines the knowledge of editors who pioneered research on the protective renin angiotensin system including; Dr. Thomas Unger, one of the founders of AT2 receptor...... research; Dr. Ulrike M. Steckelings, who contributed significantly to first preclinical studies with a novel specific AT2-agonist, and Dr. Robson Santos who pioneered research on angiotensin-(1-7) and its receptor Mas. Shows that the protective RAS axes are able to ameliorate the course of several...

  20. Advanced Neutron Source reactor control and plant protection systems design

    International Nuclear Information System (INIS)

    Anderson, J.L.; Battle, R.E.; March-Leuba, J.; Khayat, M.I.

    1992-01-01

    This paper describes the reactor control and plant protection systems' conceptual design of the Advanced Neutron Source (ANS). The Plant Instrumentation, Control, and Data Systems and the Reactor Instrumentation and Control System of the ANS are planned as an integrated digital system with a hierarchical, distributed control structure of qualified redundant subsystems and a hybrid digital/analog protection system to achieve the necessary fast response for critical parameters. Data networks transfer information between systems for control, display, and recording. Protection is accomplished by the rapid insertion of negative reactivity with control rods or other reactivity mechanisms to shut down the fission process and reduce heat generation in the fuel. The shutdown system is designed for high functional reliability by use of conservative design features and a high degree of redundance and independence to guard against single failures. Two independent reactivity control systems of different design principles are provided, and each system has multiple independent rods or subsystems to provide appropriate margin for malfunctions such as stuck rods or other single failures. Each system is capable of maintaining the reactor in a cold shutdown condition independently of the functioning of the other system. A highly reliable, redundant channel control system is used not only to achieve high availability of the reactor, but also to reduce challenges to the protection system by maintaining important plant parameters within appropriate limits. The control system has a number of contingency features to maintain acceptable, off-normal conditions in spite of limited control or plant component failures thereby further reducing protection system challenges

  1. Fire protection system operating experience review for fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, L.C.

    1995-12-01

    This report presents a review of fire protection system operating experiences from particle accelerator, fusion experiment, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of fire protection system component failure rates and fire accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with these systems are discussed, including spurious operation. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor.

  2. Fire protection system operating experience review for fusion applications

    International Nuclear Information System (INIS)

    Cadwallader, L.C.

    1995-12-01

    This report presents a review of fire protection system operating experiences from particle accelerator, fusion experiment, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of fire protection system component failure rates and fire accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with these systems are discussed, including spurious operation. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor

  3. Association between patient unconscious or not alert conditions and cardiac arrest or high-acuity outcomes within the Medical Priority Dispatch System "Falls" protocol.

    Science.gov (United States)

    Clawson, Jeff; Olola, Christopher; Scott, Greg; Schultz, Bryon; Pertgen, Richard; Robinson, Don; Bagwell, Barry; Patterson, Brett

    2010-01-01

    Falls are one of the most common types of complaints received by 9-1-1 emergency medical dispatch centers. They can be accidental or may be caused by underlying medical problems. Though "not alert" falls patients with severe outcomes mostly are "hot" transported to the hospital, some of these cases may be due to other acute medical events (cardiac, respiratory, circulatory, or neurological), which may not always be apparent to the emergency medical dispatcher (EMD) during call processing. The objective of this study was to characterize the risk of cardiac arrest and "hot-transport" outcomes in patients with "not alert" condition, within the Medical Priority Dispatch System (MPDS®) Falls protocol descriptors. This retrospective study used 129 months of de-identified, aggregate, dispatch datasets from three US emergency communication centers. The communication centers used the Medical Priority Dispatch System version 11.3-OMEGA type (released in 2006) to interrogate Emergency Medical System callers, select dispatch codes assigned to various response configurations, and provide pre-arrival instructions. The distribution of cases and percentages of cardiac arrest and hot-transport outcomes, categorized by MPDS® code, was profiled. Assessment of the association between MPDS® Delta-level 3 (D-3) "not alert" condition and cardiac arrest and hot-transport outcomes then followed. Overall, patients within the D-3 and D-2 "long fall" conditions had the highest proportions (compared to the other determinants in the "falls" protocol) of cardiac arrest and hot-transport outcomes, respectively. "Not alert" condition was associated significantly with cardiac arrest and hot-transport outcomes (pdeterminant within the MPDS® "fall" protocol was associated significantly with severe outcomes for short falls (falls. As reported to 9-1-1, the complaint of a "fall" may include the presence of underlying conditions that go beyond the obvious traumatic injuries caused by the fall itself.

  4. A critical review of the system of radiation protection

    International Nuclear Information System (INIS)

    2000-01-01

    Our modern, information society is increasingly interested in transparency and participation in many aspects of government, and this is particularly true in areas involving public health and environmental protection. Radiation protection is no exception to this trend. Scientific rationale that was once sufficient to explain radiation protection theory and practice is no longer adequate. The need to address and communicate theory, practice and the decision-making process to a wider audience has given rise to numerous debates and led the radiation protection community to revisit the framework of the system of radiation protection. The very fundamentals of the system of radiation protection continue to be questioned in a healthy fashion, and many aspects have been identified which could better serve stakeholders given some additional thought in the light of modern societal needs. This report is the summary of the NEA's first reflections in this area, and describes those aspects of the current international system of radiation protection that could be improved. Suggested directions for improvement are provided. (author)

  5. Protective, Modular Wave Power Generation System

    Energy Technology Data Exchange (ETDEWEB)

    Vvedensky, Jane M.; Park, Robert Y.

    2012-11-27

    The concept of small wave energy conversion modules that can be built into large, scalable arrays, in the same vein as solar panels, has been developed. This innovation lends itself to an organic business and development model, and enables the use of large-run manufacturing technology to reduce system costs. The first prototype module has been built to full-scale, and tested in a laboratory wave channel. The device has been shown to generate electricity and dissipate wave energy. Improvements need to be made to the electrical generator and a demonstration of an array of modules should be made in natural conditions.

  6. Concurrent validation of an index to estimate fall risk in community dwelling seniors through a wireless sensor insole system: A pilot study.

    Science.gov (United States)

    Di Rosa, Mirko; Hausdorff, Jeff M; Stara, Vera; Rossi, Lorena; Glynn, Liam; Casey, Monica; Burkard, Stefan; Cherubini, Antonio

    2017-06-01

    Falls are a major health problem for older adults with immediate effects, such as fractures and head injuries, and longer term effects including fear of falling, loss of independence, and disability. The goals of the WIISEL project were to develop an unobtrusive, self-learning and wearable system aimed at assessing gait impairments and fall risk of older adults in the home setting; assessing activity and mobility in daily living conditions; identifying decline in mobility performance and detecting falls in the home setting. The WIISEL system was based on a pair of electronic insoles, able to transfer data to a commercially available smartphone, which was used to wirelessly collect data in real time from the insoles and transfer it to a backend computer server via mobile internet connection and then onwards to a gait analysis tool. Risk of falls was calculated by the system using a novel Fall Risk Index (FRI) based on multiple gait parameters and gait pattern recognition. The system was tested by twenty-nine older users and data collected by the insoles were compared with standardized functional tests with a concurrent validity approach. The results showed that the FRI captures the risk of falls with accuracy that is similar to that of conventional performance-based tests of fall risk. These preliminary findings support the idea that theWIISEL system can be a useful research tool and may have clinical utility for long-term monitoring of fall risk at home and in the community setting. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Falls prevention for the elderly

    Directory of Open Access Journals (Sweden)

    Dagmar Lühmann

    2012-04-01

    inclusion criteria. However, to a variable degree the validity of their results must be rated as compromised due to different biasing factors. In summary, it appears that the performance of tests or the application of parameters to identify individuals at risk of falling yields little or no clinically relevant information. Positive effects of exercise interventions may be expected in relatively young and healthy seniors, while studies indicate opposite effects in the fragile elderly. For this specific vulnerable population the modification of the housing environment shows protective effects. A low number of studies, low quality of studies or inconsistent results lead to the conclusion that the effectiveness of the following interventions has to be rated unclear yet: correction of vision disorders, modification of psychotropic medication, vitamin D supplementation, nutritional supplements, psychological interventions, education of nursing personnel, multiple and multifactorial programs as well as the application of hip protectors. For the context of the German health care system the economic evaluations of fall prevention retrieved by the literature searches yield very few useful results. Cost-effectiveness calculations of fall prevention are mostly based on weak effectiveness data as well as on epidemiological and cost data from foreign health care systems. Ethical analysis demonstrates ambivalent views of the target population concerning fall risk and the necessity of fall prevention. The willingness to take up preventive measures depends on a variety of personal factors, the quality of information, guidance and decision-making, the prevention program itself and social support. The analysis of papers regarding legal issues shows three main challenges: the uncertainty of which standard of care has to be expected with regard to fall prevention, the necessity to consider the specific conditions of every single case when measures for fall prevention are applied, and the

  8. Falls prevention for the elderly.

    Science.gov (United States)

    Balzer, Katrin; Bremer, Martina; Schramm, Susanne; Lühmann, Dagmar; Raspe, Heiner

    2012-01-01

    results must be rated as compromised due to different biasing factors. In summary, it appears that the performance of tests or the application of parameters to identify individuals at risk of falling yields little or no clinically relevant information. Positive effects of exercise interventions may be expected in relatively young and healthy seniors, while studies indicate opposite effects in the fragile elderly. For this specific vulnerable population the modification of the housing environment shows protective effects. A low number of studies, low quality of studies or inconsistent results lead to the conclusion that the effectiveness of the following interventions has to be rated unclear yet: correction of vision disorders, modification of psychotropic medication, vitamin D supplementation, nutritional supplements, psychological interventions, education of nursing personnel, multiple and multifactorial programs as well as the application of hip protectors. For the context of the German health care system the economic evaluations of fall prevention retrieved by the literature searches yield very few useful results. Cost-effectiveness calculations of fall prevention are mostly based on weak effectiveness data as well as on epidemiological and cost data from foreign health care systems. Ethical analysis demonstrates ambivalent views of the target population concerning fall risk and the necessity of fall prevention. The willingness to take up preventive measures depends on a variety of personal factors, the quality of information, guidance and decision-making, the prevention program itself and social support. THE ANALYSIS OF PAPERS REGARDING LEGAL ISSUES SHOWS THREE MAIN CHALLENGES: the uncertainty of which standard of care has to be expected with regard to fall prevention, the necessity to consider the specific conditions of every single case when measures for fall prevention are applied, and the difficulty to balance the rights to autonomous decision making and physical

  9. A machine protection beam position monitor system

    International Nuclear Information System (INIS)

    Medvedko, E.; Smith, S.; Fisher, A.

    1998-01-01

    Loss of the stored beam in an uncontrolled manner can cause damage to the PEP-II B Factory. We describe here a device which detects large beam position excursions or unexpected beam loss and triggers the beam abort system to extract the stored beam safely. The bad-orbit abort trigger beam position monitor (BOAT BPM) generates a trigger when the beam orbit is far off the center (>20 mm), or rapid beam current loss (dI/dT) is detected. The BOAT BPM averages the input signal over one turn (136 kHz). AM demodulation is used to convert input signals at 476 MHz to baseband voltages. The detected signal goes to a filter section for suppression of the revolution frequency, then on to amplifiers, dividers, and comparators for position and current measurements and triggering. The derived current signal goes to a special filter, designed to perform dI/dT monitoring at fast, medium, and slow current loss rates. The BOAT BPM prototype test results confirm the design concepts

  10. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve ''control loops'' between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  11. Advanced worker protection system. Topical report, Phase I

    Energy Technology Data Exchange (ETDEWEB)

    Myers, J.

    1995-07-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system, maintenance, and dramatically improve worker productivity through longer duration work cycles.

  12. Reactor protection systems for the Replacement Research Reactor, ANSTO

    International Nuclear Information System (INIS)

    Morris, C.R.

    2003-01-01

    The 20-MW Replacement Research Reactor Project which is currently under construction at ANSTO will have a combination of a state of the art triplicated computer based reactor protection system, and a fully independent, and diverse, triplicated analogue reactor protection system, that has been in use in the nuclear industry, for many decades. The First Reactor Protection System (FRPS) consists of a Triconex triplicated modular redundant system that has recently been approved by the USNRC for use in the USA?s power reactor program. The Second Reactor Protection System is a hardwired analogue system supplied by Foxboro, the Spec 200 system, which is also Class1E qualified. The FRPS is used to drop the control rods when its safety parameter setpoints have been reached. The SRPS is used to drain the reflector tank and since this operation would result in a reactor poison out due to the time it would take to refill the tank the FRPS trip setpoints are more limiting. The FRPS and SRPS have limited hardwired indications on the control panels in the main control room (MCR) and emergency control centre (ECC), however all FRPS and SRPS parameters are capable of being displayed on the reactor control and monitoring system (RCMS) video display units. The RCMS is a Foxboro Series I/A control system which is used for plant control and monitoring and as a protection system for the cold neutron source. This paper will provide technical information on both systems, their trip logics, their interconnections with each other, and their integration into the reactor control and monitoring system and control panels. (author)

  13. Cold Vacuum Drying facility fire protection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) fire protection system (FPS). The FPS provides fire detection, suppression, and loss limitation for the CVDF structure, personnel, and in-process spent nuclear fuel. The system provides, along with supporting interfacing systems, detection, alarm, and activation instrumentation and controls, distributive piping system, isolation valves, and materials and controls to limit combustibles and the associated fire loadings

  14. Reliability of redundant structures of nuclear reactor protection systems

    International Nuclear Information System (INIS)

    Vojnovic, B.

    1983-01-01

    In this paper, reliability of various redundant structures of PWR protection systems has been analysed. Structures of reactor tip systems as well as the systems for activation of safety devices have been presented. In all those systems redundancy is achieved by means of so called majority voting logic ('r out of n' structures). Different redundant devices have been compared, concerning probability of occurrence of safe as well as unsafe failures. (author)

  15. Railway automatic safety protection system based on GPS

    Directory of Open Access Journals (Sweden)

    Fu Hai Juan

    2016-01-01

    Full Text Available The automatic protection system of railway safety is designed for the railway construction workers to protect alarm, and the safety protection device by using GPS satellite positioning system to acquire location information of the operating point, through the CTC/TDCS system and computer monitoring system for the running of the train position and the arithmetic distance. Achieving timely and continuously forecasts about the distance of the train which is apart from the operating point to prompt the voice alarm of the approaching train. Using digital technology to realize the function of the traditional analog interphone, eliminates the quality problems of the call. With the GSM-R, mobile wireless transmission channel and terminal technology, it overcomes the restrictions of the analog interphone which influenced by communication distance and more problems of blind areas. Finally to achieve practical, convenient, applicable and adaptable design goals.

  16. Adoption of digital safety protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Z.

    1998-01-01

    The application of micro-processor-based digital controllers has been widely propagated among various industries in recent years. While in the nuclear power plant industry, the application of them has also been expanding gradually starting from non-safety related systems, taking advantage of their reliability and maintainability over the conventional analog devices. Based on the careful study of the feasibility of digital controllers to the safety protection system, the Tokyo Electric Power Company proposed on May 1989 the adoption of digital controllers to the safety protection system in the Application for Permission of Establishment of Kashiwazaki-Kariwa units 6 and 7 (ABWR-1350Mwe each). MITI, Ministry of International Trade and Industry, the Japanese regulatory body for electric power generating facilities, had approved this application after careful review. This paper describes a series of supporting activities leading to the MITI's approval of the digital safety protection system and the MITI's licensing activities. (author)

  17. Study of Physical Protection System at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Ligam, A.S.; Ina, I.; Zarina Masood

    2016-01-01

    Physical protection program at PUSPATI TRIGA Reactor (RTP) which is located at Nuklear Malaysia, Bangi Complex has been strengthened and upgraded from time to time to accommodate current situation needs. However, there is always room for improvement. Hence, study have been made to look deeper into physical protection components such as delay systems, external sensors, PPS intruder alarm sensors, use of video system, personnel security or insider threats, access control operation system operation rules and security culture that may need to take into consideration. (author)

  18. Alternative High Performance Polymers for Ablative Thermal Protection Systems

    Science.gov (United States)

    Boghozian, Tane; Stackpoole, Mairead; Gonzales, Greg

    2015-01-01

    Ablative thermal protection systems are commonly used as protection from the intense heat during re-entry of a space vehicle and have been used successfully on many missions including Stardust and Mars Science Laboratory both of which used PICA - a phenolic based ablator. Historically, phenolic resin has served as the ablative polymer for many TPS systems. However, it has limitations in both processing and properties such as char yield, glass transition temperature and char stability. Therefore alternative high performance polymers are being considered including cyanate ester resin, polyimide, and polybenzoxazine. Thermal and mechanical properties of these resin systems were characterized and compared with phenolic resin.

  19. Motor drive chassis for the plutonium protection system

    International Nuclear Information System (INIS)

    Shaut, A.L.

    1979-05-01

    A motor drive chassis has been developed for use in the Plutonium Protection System. Rotation of the desired carrousel in a secure storage module is controlled by this chassis which supplies the power and drive pulses required by the carrousel motor. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Physical Protection Program

  20. Students fall for Fall Meeting

    Science.gov (United States)

    Smedley, Kara

    2012-02-01

    From Boston to Beijing, thousands of students traveled to San Francisco for the 2011 AGU Fall Meeting. Of those who participated, 183 students were able to attend thanks to AGU's student travel grant program, which assists students with travel costs and seeks to enrich the meeting through ethnic and gender diversity. Students at Fall Meeting enjoyed a variety of programs and activities designed to help them better network with their peers, learn about new fields, and disseminate their research to the interested public. More than 800 students attended AGU's first annual student mixer, sharing drinks and ideas with fellow student members and future colleagues as well as forging new friendships and intellectual relationships.

  1. A Westinghouse designed distributed mircroprocessor based protection and control system

    International Nuclear Information System (INIS)

    Bruno, J.; Reid, J.B.

    1980-01-01

    For approximately five years, Westinghouse has been involved in the design and licensing of a distributed microprocessor based system for the protection and control of a pressurized water reactor nuclear steam supply system. A 'top-down' design methodology was used, in which the system global performance objectives were specified, followed by increasingly more detailed design specifications which ultimately decomposed the system into its basic hardware and software elements. The design process and design decisions were influenced by the recognition that the final product would have to be verified to ensure its capability to perform the safety-related functions of a class 1E protection system. The verification process mirrored the design process except that it was 'bottom-up' and thus started with the basic elements and worked upwards through the system in increasingly complex blocks. A number of areas which are of interest in a distributed system are disucssed, with emphasis on two systems. The first, the Integrated Protection System is primarily responsible for processing signals from field mounted sensors to provide for reactor trips and the initiation of the Engineered Safety Features. The Integrated Control System, which is organized in a parallel manner, processes other sensor signals and generates the necessary analog and on-off signals to maintain the plant parameters within specified limits. Points covered include system structure, systems partitioning strategies, communications techniques, software design concepts, reliability and maintainability, commercial component availability, interference susceptibility, licensing issues, and applicability. (LL)

  2. Optical bus of centralized relay protection and automation system of ...

    African Journals Online (AJOL)

    The article deals with the system of information collection and transfer from a centralized relay protection and automation system for medium voltage electrical units based on a passive optical bus. The issues of electromagnetic compatibility of technical devices are also considered, and the intensity of electromagnetic ...

  3. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  4. Problems in creating enviroment and health protection systems

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Reznichenko, V.Yu.

    1981-01-01

    The problems in creating environmental and health protection systems are considered with relation to development of nuclear energetics facilities. A problem of transition from the system of detection and observation to the uniform system of environment and health protection and control is set. The objectives and problems of such a system are analyzed and the basic principles of their construction are outlined. A system conception for a fuel energetic complex is described. Usefulness of such systems in solving problems of sites of industrial objects including nuclear power industrial objects, of removal of these objects from service and etc. is shown. New requirements to medical-biological investigations on designing of such a system are discussed [ru

  5. Intelligent, Self-Diagnostic Thermal Protection System for Future Spacecraft

    Science.gov (United States)

    Hyers, Robert W.; SanSoucie, Michael P.; Pepyne, David; Hanlon, Alaina B.; Deshmukh, Abhijit

    2005-01-01

    The goal of this project is to provide self-diagnostic capabilities to the thermal protection systems (TPS) of future spacecraft. Self-diagnosis is especially important in thermal protection systems (TPS), where large numbers of parts must survive extreme conditions after weeks or years in space. In-service inspections of these systems are difficult or impossible, yet their reliability must be ensured before atmospheric entry. In fact, TPS represents the greatest risk factor after propulsion for any transatmospheric mission. The concepts and much of the technology would be applicable not only to the Crew Exploration Vehicle (CEV), but also to ablative thermal protection for aerocapture and planetary exploration. Monitoring a thermal protection system on a Shuttle-sized vehicle is a daunting task: there are more than 26,000 components whose integrity must be verified with very low rates of both missed faults and false positives. The large number of monitored components precludes conventional approaches based on centralized data collection over separate wires; a distributed approach is necessary to limit the power, mass, and volume of the health monitoring system. Distributed intelligence with self-diagnosis further improves capability, scalability, robustness, and reliability of the monitoring subsystem. A distributed system of intelligent sensors can provide an assurance of the integrity of the system, diagnosis of faults, and condition-based maintenance, all with provable bounds on errors.

  6. Safety Protection of Series Connected Hybrid Cryogenic System

    Science.gov (United States)

    Bai, Hongyu; Bird, Mark D.; Bole, Scott T.; Cantrell, Kurtis R.; Dixon, Iain R.; Gavrilin, Andrew V.; Painter, Thomas A.; Xu, Ting

    2010-04-01

    Two Series Connected Hybrid (SCH) magnets are under construction at the National High Magnetic Field Laboratory. In the SCH system, consisting of a resistive insert and a superconducting outsert, the outsert superconducting coil is wound with Cable in Conduit Conductor (CICC) and cooled with forced-flow supercritical helium at 4.5 K. The forced-flow helium is supplied from a helium refrigerator. In the design of the cryogenic system for the series-connected hybrid, the possible failure of the magnet system should be considered and the cryogenic system should be safely protected in the event of failure. In the SCH system, a protected quench of the superconducting magnet, a loss of vacuum in the cryostat and an unprotected quench were analyzed. Active venting valves, safety valves and burst disks are used for the protection of the cryogenic system and cryostat in the case of the occurrence of failure modes. The design of the safety protection system and the analysis results in the failure modes are discussed.

  7. Older Adults' Perceptions of and Preferences for a Fall Risk Assessment System: Exploring Stages of Acceptance Model.

    Science.gov (United States)

    Galambos, Colleen; Rantz, Marilyn; Back, Jessie; Jun, Jung Sim; Skubic, Marjorie; Miller, Steven J

    2017-07-01

    Aging in place is a preferred and cost-effective living option for older adults. Research indicates that technology can assist with this goal. Information on consumer preferences will help in technology development to assist older adults to age in place. The study aim was to explore the perceptions and preferences of older adults and their family members about a fall risk assessment system. Using a qualitative approach, this study examined the perceptions, attitudes, and preferences of 13 older adults and five family members about their experience living with the fall risk assessment system during five points in time. Themes emerged in relation to preferences and expectations about the technology and how it fits into daily routines. We were able to capture changes that occurred over time for older adult participants. Results indicated that there was acceptance of the technology as participants adapted to it. Two themes were present across the five points in time-safety and usefulness. Five stages of acceptance emerged from the data from preinstallation to 2 years postinstallation. Identified themes, stages of acceptance, and design and development considerations are discussed.

  8. Management information system applied to radiation protection services

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur, E-mail: pabloag@cdtn.br, E-mail: lss@cdtn.br, E-mail: gmf@cdtn.br, E-mail: arthurqof@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  9. A secure steganography for privacy protection in healthcare system.

    Science.gov (United States)

    Liu, Jing; Tang, Guangming; Sun, Yifeng

    2013-04-01

    Private data in healthcare system require confidentiality protection while transmitting. Steganography is the art of concealing data into a cover media for conveying messages confidentially. In this paper, we propose a steganographic method which can provide private data in medical system with very secure protection. In our method, a cover image is first mapped into a 1D pixels sequence by Hilbert filling curve and then divided into non-overlapping embedding units with three consecutive pixels. We use adaptive pixel pair match (APPM) method to embed digits in the pixel value differences (PVD) of the three pixels and the base of embedded digits is dependent on the differences among the three pixels. By solving an optimization problem, minimal distortion of the pixel ternaries caused by data embedding can be obtained. The experimental results show our method is more suitable to privacy protection of healthcare system than prior steganographic works.

  10. Internship Progress Summary: Fall 2016

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ralph S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Valencia, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-13

    This fall I had the opportunity to work at Los Alamos National Laboratory for the Technology Applications engineering group. I assisted two main projects during my appointment, both related to the Lab’s mission statement: “To solve national security challenges through scientific excellence.” My first project, a thermal source transfer unit, involved skills such as mechanical design, heat transfer simulation, and design analysis. The goal was to create a container that could protect a heat source and regulate its temperature during transit. I generated several designs, performed heat transfer simulations, and chose a design for prototyping. The second project was a soil drying unit for use in post blast sample analysis. To ensure fast and accurate sample processing, agents in the field wanted a system that could process wet dirt and turn it into dry powder. We designed a system of commercially available parts, and we tested the systems to determine the best methods and processes.

  11. Development of a Smart Residential Fire Protection System

    Directory of Open Access Journals (Sweden)

    Juhwan Oh

    2013-01-01

    Full Text Available Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual fire test suggests that the developed wireless system for the smart residential fire protection system is reliable in terms of sensors and their communication linkage.

  12. Reactor core protection system using a 4-channel microcomputer

    International Nuclear Information System (INIS)

    Mertens, U.

    1982-12-01

    A four channel microcomputer system was fitted in Grafenrheinfeld NPP for local core protection. This system performs continuous on-line monitoring of peak power density, departure from nucleate boiling ratio and fuel duty. The system implements limitation functions with more sophisticated criteria and improved accuracy. The Grafenrheinfeld system points the way to the employment of computer based limitation system, particularly in the field of programming language, demarkation of tasks, commissioning and documentation aids, streamlining of qualification and structuring of the system. (orig.) [de

  13. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  14. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  15. Lightning Protection System to the Indian Satellite Launch Pad

    OpenAIRE

    Nagabushana, GR; Thomas, Joy; Kumar, Udaya; Rao, Venkateshwara D; Rao, Panduranga PV

    1999-01-01

    Any satellite launch mission forms a complex and expensive process. Intensive care and precautions are to be taken for a safe and successful launch. Also, the satellite launch system forms a tall structure standing on a plane terrain. As a result, a lightning strike rate to it becomes more probable. Therefore, extensive care needs to be taken in shielding the launch system against natural lightning. Lightning protection systems built with differing principles have been in use at different lau...

  16. FAULT-TOLERANT DESIGN FOR ADVANCED DIVERSE PROTECTION SYSTEM

    OpenAIRE

    YANG GYUN OH; JIN KWON JEONG; CHANG JAE LEE; YOON HEE LEE; SEUNG MIN BAEK; SANG JEONG LEE

    2013-01-01

    For the improvement of APR1400 Diverse Protection System (DPS) design, the Advanced DPS (ADPS) has recently been developed to enhance the fault tolerance capability of the system. Major fault masking features of the ADPS compared with the APR1400 DPS are the changes to the channel configuration and reactor trip actuation equipment. To minimize the fault occurrences within the ADPS, and to mitigate the consequences of common-cause failures (CCF) within the safety I&C systems, several fault avo...

  17. Mitigating fall risk: A community fall reduction program.

    Science.gov (United States)

    Reinoso, Humberto; McCaffrey, Ruth G; Taylor, David W M

    One fourth of all American's over 65 years of age fall each year. Falls are a common and often devastating event that can pose a serious health risk for older adults. Healthcare providers are often unable to spend the time required to assist older adults with fall risk issues. Without a team approach to fall prevention the system remains focused on fragmented levels of health promotion and risk prevention. The specific aim of this project was to engage older adults from the community in a fall risk assessment program, using the Stopping Elderly Accidents, Deaths & Injuries (STEADI) program, and provide feedback on individual participants' risks that participants could share with their primary care physician. Older adults who attended the risk screening were taking medications that are known to increase falls. They mentioned that their health care providers do not screen for falls and appreciated a community based screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Limerick BWR turbine control and protection system upgrade success

    Energy Technology Data Exchange (ETDEWEB)

    Tang, C.K.; Pietryka, T.S.; Federico, P.A., E-mail: tangck@westinghouse.com, E-mail: pietryt@westinghouse, E-mail: federipa@westinghouse.com [Westinghouse Electric Company, LLC, Cranberry Township, PA (United States); Williams, J.C., E-mail: Jonathan.Williams@exeloncorp.com [Exelon Nuclear, Warrenville, IL (United States)

    2015-07-01

    Westinghouse and Exelon have successfully implemented a digital electro-hydraulic control (DEHC) at Limerick BWR Unit 1 Station to perform the turbine control, protection and reactor pressure functions. The DEHC replaces analog controls and addressed system performance, obsolescence and reliability. This was a first-of-a-kind application for control and protection of the main turbine and BWR pressure control for the distributed control system utilized. The demolition of analog equipment, main control room and front standard modifications, and acceptance testing were completed on schedule during the normal 2014 outage. Key aspects of the project that facilitated this success will be discussed and presented. (author)

  19. Limerick BWR turbine control and protection system upgrade success

    International Nuclear Information System (INIS)

    Tang, C.K.; Pietryka, T.S.; Federico, P.A.; Williams, J.C.

    2015-01-01

    Westinghouse and Exelon have successfully implemented a digital electro-hydraulic control (DEHC) at Limerick BWR Unit 1 Station to perform the turbine control, protection and reactor pressure functions. The DEHC replaces analog controls and addressed system performance, obsolescence and reliability. This was a first-of-a-kind application for control and protection of the main turbine and BWR pressure control for the distributed control system utilized. The demolition of analog equipment, main control room and front standard modifications, and acceptance testing were completed on schedule during the normal 2014 outage. Key aspects of the project that facilitated this success will be discussed and presented. (author)

  20. Random Vibration of Space Shuttle Weather Protection Systems

    Directory of Open Access Journals (Sweden)

    Isaac Elishakoff

    1995-01-01

    Full Text Available The article deals with random vibrations of the space shuttle weather protection systems. The excitation model represents a fit to the measured experimental data. The cross-spectral density is given as a convex combination of three exponential functions. It is shown that for the type of loading considered, the Bernoulli-Euler theory cannot be used as a simplified approach, and the structure will be more properly modeled as a Timoshenko beam. Use of the simple Bernoulli-Euler theory may result in an error of about 50% in determining the mean-square value of the bending moment in the weather protection system.

  1. Epidemiology of falls in older age.

    Science.gov (United States)

    Peel, Nancye May

    2011-03-01

    Worldwide, falls among older people are a public health concern because of their frequency and adverse consequences in terms of morbidity, mortality, and quality of life, as well as their impact on health system services and costs. This epidemiological review outlines the public health burden of falls and fall-related injuries and the impact of population aging. The magnitude of the problem is described in terms of the classification of falls and measurement of outcomes, including fall incidence rates across settings, sociodemographic determinants, international trends, and costs of falls and fall-related injuries. Finally, public health approaches to minimize falls risk and consequent demand on health care resources are suggested.

  2. Assurance of risk assessment and protection distant transportation and fall out of pollutants under large anthropogenic on nuclear power stations due to mountainous regional peculiarities

    International Nuclear Information System (INIS)

    Tsitskishvili, M.; Tsitskishvili, N.; Kordzakhia, G.; Valiaev, A.; Kazakov, S.; Aitmatov, I.; Petrov, V.

    2005-01-01

    Full text: All types of industrial activities require the norms of protection, assessment of corresponding risks to preserve the pollution and degradation of corresponding areas. To make available the sustainable development of the country the risk assessment of possible accidents on the big enterprises is foreseen that provides preparedness of the country and possibility of the prevention measures and mitigation of the accidents. While big anthropogenic accidents in mountainous countries - the main paths for transportation of the pollution are the rivers and sea basins. Due to overpopulation of these areas assessment of the pollution risks are very important. Problem of forecast and distant atmospheric transportation of the toxic products and corresponding risk assessment under anthropogenic damages is multi-component and depends on meteorological conditions and frontier layer of atmosphere. Generally, for real relief and basic fields the problem is not solved yet especially taking into consideration the big level and shortest time of the process being of the natural anthropogenic accidents in mountainous regions. Usually, geostropic drawing for determined relief is used. Integral differential equations taking into consideration a physical- chemical characteristic of the pollutants, their transformations, fall out, coagulations, washing out and self rectification in general cannot be solved. In last time essential success in formalization of above-mentioned equations i.e. carrying out some simplifications give possibility to establish necessary modeling on the basis of numerical calculations. In the most general case forecasting model is essentially limited because of bulky size of accounting schemes and necessity of powerful and high-speed computers. Main ways of achievement of further success is connected with so called 'seasonal typification' with applied a priory calculation of probabilistic picture of the pollutants concentration fields, as well as

  3. Ground-level falls: 9-year cumulative experience in a regionalized trauma system

    Science.gov (United States)

    Cade, Angela; King, Brad; Berne, John; Fernandez, Luis; Norwood, Scott

    2012-01-01

    Ground-level falls (GLFs) are the leading cause of nonfatal hospitalized injuries in the US. We hypothesized that risk-adjusted mortality would not vary between levels of trauma center verification if regional triage functioned appropriately. Data were collected from our regional trauma registry for the years 2001 through 2009. A multilevel mixed-effects logistic regression model was developed to compare risk-adjusted mortality rates by trauma center level and by year. GLF patients numbered 8202 over 9 years with 2.1% mortality. Mean age was 74.5 years and mean probability of death was 0.021 (95% confidence interval [CI], 0.020–0.021). The level I center–treated patients had the highest probability of death (0.033) compared to levels II and III/IV patients (0.023 and 0.018, respectively; P < 0.001), with the highest mortality (6.0%, 3.1%, and 1.1% for levels I, II, and III/IV; P < 0.001). The adjusted odds ratio of mortality was lowest at the level I center (0.71; 95% CI, 0.56–0.91), while no difference existed between level II (1.17; 95% CI, 0.90–1.51) and level III/IV centers (1.22; 95% CI, 0.90–1.66). The 95% CIs for risk-adjusted mortality by year overlapped the 1.0 reference line for each year from 2002 to 2009. In conclusion, regional risk-adjusted mortality for GLF has varied little since 2002. More study is warranted to understand the lower risk-adjusted GLF mortality at the level I center for this growing patient population. PMID:22275774

  4. Respiratory protective device design using control system techniques

    Science.gov (United States)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  5. Software V ampersand V methods for digital plant protection system

    International Nuclear Information System (INIS)

    Kim, Hung-Jun; Han, Jai-Bok; Chun, Chong-Son; Kim, Sung; Kim, Kern-Joong.

    1997-01-01

    Careful thought must be given to software design in the development of digital based systems that play a critical role in the successful operation of nuclear power plants. To evaluate the software verification and validation methods as well as to verify its system performance capabilities for the upgrade instrumentation and control system in the Korean future nuclear power plants, the prototype Digital Plant, Protection System (DPPS) based on the Programmable Logic Controller (PLC) has been constructed. The system design description and features are briefly presented, and the software design and software verification and validation methods are focused. 6 refs., 2 figs

  6. New technology for reactor protection system of CAREM reactor

    International Nuclear Information System (INIS)

    Dezzutti, J.C.; Verrastro, C.; Estryk, D.

    2009-01-01

    The use of FPGA in safety functions in a nuclear power plant, increase the reliability of software based systems, without loose any of the function required by the supervision and control systems. In this work the architecture of a Reactor Protection System is described, it use four independent measurement channels in 2 oo 4 configuration, each channel is based on diverse approach in 1 oo 2 configuration, the reliability of this system is near the same than the hardwired logic, with full performance like software based system. (author)

  7. Requirement of system-reservoir bound states for entanglement protection

    Science.gov (United States)

    Behzadi, N.; Ahansaz, B.; Faizi, E.; Kasani, H.

    2018-03-01

    In this work, a genuine mechanism for entanglement protection of a two- qubit system interacting with a dissipative common reservoir is investigated. Based on generating a bound state for the system-reservoir, we show that stronger bound state in the energy spectrum can be created by adding another non-interacting qubits into the reservoir. It turns out that obtaining higher degrees of boundedness in the energy spectrum leads to a better protection of two-qubit entanglement against the dissipative noises. Also, it is figured out that the formation of bound state not only exclusively determines the long-time entanglement protection, irrespective to the Markovian and non-Markovian dynamics, but also performs the same task for reservoirs with different spectral densities.

  8. Operating Systems-Functions, Protection and Security Mechanisms

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 7; Issue 4. Operating Systems - Functions, Protection and Security Mechanisms. M Suresh Babu. General Article Volume 7 Issue 4 April 2002 pp 60-66. Fulltext. Click here to view fulltext PDF. Permanent link:

  9. Space Shuttle Orbiter thermal protection system design and flight experience

    Science.gov (United States)

    Curry, Donald M.

    1993-01-01

    The Space Shuttle Orbiter Thermal Protection System materials, design approaches associated with each material, and the operational performance experienced during fifty-five successful flights are described. The flights to date indicate that the thermal and structural design requirements were met and that the overall performance was outstanding.

  10. The core protection computer system fitted in Grafenrheinfeld NPP

    International Nuclear Information System (INIS)

    Rietzsch, L.

    1986-01-01

    This paper gives an overview of a four-train core protection computer system for KWU pressurized water reactors. Attention is focused on the methods used to ensure correct computer operation and correct results. Experience gained in trial operation is dealt with. Results of safety analysis of the hardware and the software verification work performed are discussed. (author)

  11. Programming microphysiological systems for children's health protection (SEBM meeting)

    Science.gov (United States)

    Presentation: Programming microphysiological systems for children’s health protectionAuthors: Knudsen1 T, Klieforth2 B, and Slikker3 W Jr.1National Center for Computational Toxicology/EPA, Research Triangle Park NC2National Center for Environmental Research/EPA, Washington DC3Nat...

  12. PATTERNS AND DESIGN PROTECTION SYSTEMS IN ROMANIAN LAW

    Directory of Open Access Journals (Sweden)

    OVIDIA JANINA IONESCU

    2012-05-01

    Full Text Available Because of the significant differences among the laws of member states in the field of design and patterns, by Council Directive No. 98/71/EC of 13 October 1998 on the legal protection of patterns and designs, the European Parliament has implemented a patterns and design protection system adapted to the needs of any domestic market.Based on Directive No. 98/71/EC, the Council Regulation (EU No. 6/2002 of 12 December 2001 on community designs and patterns has been issued, being compulsory in all its elements and applying directly to all member states. Thus, a special legal protection has been provided, which is meant to encourage individual creators to bring forward innovation, the development of new products and investments in their manufacturing. In order to implement the provisions of Regulation (EU No. 6/2002, the Commission Regulation (EU No. 2245/2002 of 21 October 2002 has been adopted. All these regulations are intended to provide protection of designs and patterns, and for this purpose two forms of protection are deemed necessary, i.e. a long-term one, corresponding to unregistered designs or patterns, and a short-term one, corresponding to registered designs and patters. In this paper we shall present in detail these forms of protection, as well as the substantive and formal conditions necessary to be fulfilled for the registration of designs and patterns. The presentation shall be founded on the legal regulations mentioned above that are enforceable and binding also on the Romanian territory, a legal protection of design and patterns being thus provided not only inland but also intra-community. The purpose of this paper is to also highlight the necessity of design and patterns protection, a sine-qua-non condition for the development of new products and investments.

  13. Technological measures of protection in the copyright system

    Directory of Open Access Journals (Sweden)

    Radovanović Sanja

    2011-01-01

    Full Text Available Digital exploitation of works often exceed the limit to which the holder can control the exploitation of their intellectual creations, and the protection provided by legal norms are, in the era of a fast exchange of information, may prove to be insufficiently effective. For these reasons, the rights holders are increasingly opting for preventive care through placement of physical obstacles to the exploitation of copyright works, generic called technological protection measures (known as digital right management (DRM. Simultaneously with the development of the application of these measures flows the process of finding ways to circumvent them. Therefore, the effectiveness of technological measures depends on exactly the question of their legal protection, which now exists in most of modern legal systems. However, in the normative solutions there are differences, which reflect the problems in finding adequate forms of protection. They mostly stem from the fact that the sanctioning of circumvention (or preparatory actions of technological measures put into the question the purpose of copyright protection in general. Hence, in this paper we tried to point out the normative solutions accepted in modern legal systems and practical implications of what they have. Conclusion that arises is that the legal shaping of technological measures is not completed and that further technological developments open new dilemmas.

  14. Software reliability and safety in nuclear reactor protection systems

    International Nuclear Information System (INIS)

    Lawrence, J.D.

    1993-11-01

    Planning the development, use and regulation of computer systems in nuclear reactor protection systems in such a way as to enhance reliability and safety is a complex issue. This report is one of a series of reports from the Computer Safety and Reliability Group, Lawrence Livermore that investigates different aspects of computer software in reactor National Laboratory, that investigates different aspects of computer software in reactor protection systems. There are two central themes in the report, First, software considerations cannot be fully understood in isolation from computer hardware and application considerations. Second, the process of engineering reliability and safety into a computer system requires activities to be carried out throughout the software life cycle. The report discusses the many activities that can be carried out during the software life cycle to improve the safety and reliability of the resulting product. The viewpoint is primarily that of the assessor, or auditor

  15. Software reliability and safety in nuclear reactor protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, J.D. [Lawrence Livermore National Lab., CA (United States)

    1993-11-01

    Planning the development, use and regulation of computer systems in nuclear reactor protection systems in such a way as to enhance reliability and safety is a complex issue. This report is one of a series of reports from the Computer Safety and Reliability Group, Lawrence Livermore that investigates different aspects of computer software in reactor National Laboratory, that investigates different aspects of computer software in reactor protection systems. There are two central themes in the report, First, software considerations cannot be fully understood in isolation from computer hardware and application considerations. Second, the process of engineering reliability and safety into a computer system requires activities to be carried out throughout the software life cycle. The report discusses the many activities that can be carried out during the software life cycle to improve the safety and reliability of the resulting product. The viewpoint is primarily that of the assessor, or auditor.

  16. System of nuclear power reactor protection using dynamic logic

    International Nuclear Information System (INIS)

    Carvalho, P.V.R. de; Silva, L.C.R.P. da

    1990-01-01

    The aim of this work is the design of a Reactor Protection System (RPS) using dynamic logic as basic circuitry principle. This concept was developed to permit the electronic and eletromagnetic components employment in 'fail-safe' mode applied to automatic shutdown systems. 'Fail-safe' here means that a fail always yields a constant state that leads to a plant shutdown condition. So the normal condition of operation corresponds to an oscillating state response and the fail or abnormal condition to a static one. At present, almost all modern nuclear plant reactor protection systems use dynamic logic, just differing in the kind of technology employed in the construction of the system. In this work we define what technology best fits our necessities, setting out to design a RPS based on this philosophy. (author) [pt

  17. Advancement adopted for physical protection system at BARC facilities Tarapur

    International Nuclear Information System (INIS)

    Jaroli, Manish; Ameta, Rohit; Patil, V.H.; Dubey, K.

    2015-01-01

    Considering the prevailing security situation and threat perception to the nuclear installations in particular, it has become essential to strengthen security system at BARC Tarapur in an effective manner to avert any attempt of sabotage and to ensure smooth functioning of security and safety of the nuclear installations. International Atomic Energy Agency (IAEA) and Atomic Energy Regulatory Board (AERB) have provided various security guides for the physical protection system (PPS) for nuclear installations and there has been advancement in physical and personnel protection system due to evolution of new technologies. In line with this, latest technologies have been adopted in PPS for BARC facilities, Tarapur recently. This includes state of art RFID card based access control, visitor and contractor management system, electronic key management system. Digital signature based biometric visitor and contractor management system; Digital signature based leave management system; Distress alarm system (DAS); Guard tour monitoring system (GTMS); Secure network access system (SNAS) as well as multilayered access control system at plant level. This will strengthen the surveillance and monitoring of personnel and visitors at BARC facilities. (author)

  18. Dedicated monitoring and machinery protection systems on reciprocating compressors

    Energy Technology Data Exchange (ETDEWEB)

    Grande, Alvaro; Wenisch, Markus [Hoerbiger Ventilwerke GmbH and Co KG, Wien (Austria); Jacobs, Denis [HOERBIGER do Brasil Industria de Equipamentos, Cajamar, SP (Brazil)

    2012-07-01

    Growing demands on reciprocating compressors (recips) in the process gas industry require particular solutions for machinery protection and performance monitoring systems. Compared to rotating equipment, monitoring systems for recips have to consider the special mechanical and physical characteristics, such as oscillating masses, variable vibration behaviour and varying operating conditions. Furthermore, they provide valuable information about the performance of cylinder related components allowing the operator the optimization of efficiency and availability, and therefore increase production. (author)

  19. Two IP Protection Schemes for Multi-FPGA Systems

    OpenAIRE

    Gaspar, Lubos; Fischer, Viktor; Guneysu, Tim; Cherif, Zouha

    2012-01-01

    International audience; This paper proposes two novel protection schemes for multi-FPGA systems providing high security of IP designs licensed by IP vendors to system integrators and installed remotely in a hostile environment. In the first scheme, these useful properties are achieved by storing two different configuration keys inside an FPGA, while in the second scheme, they are obtained using a hardware white-box cipher for creating a trusted environment. Thanks to the proposed principles, ...

  20. Impact Testing of Orbiter Thermal Protection System Materials

    Science.gov (United States)

    Kerr, Justin

    2006-01-01

    This viewgraph presentation reviews the impact testing of the materials used in designing the shuttle orbiter thermal protection system (TPS). Pursuant to the Columbia Accident Investigation Board recommendations a testing program of the TPS system was instituted. This involved using various types of impactors in different sizes shot from various sizes and strengths guns to impact the TPS tiles and the Leading Edge Structural Subsystem (LESS). The observed damage is shown, and the resultant lessons learned are reviewed.

  1. Vision-based pedestrian protection systems for intelligent vehicles

    CERN Document Server

    Geronimo, David

    2013-01-01

    Pedestrian Protection Systems (PPSs) are on-board systems aimed at detecting and tracking people in the surroundings of a vehicle in order to avoid potentially dangerous situations. These systems, together with other Advanced Driver Assistance Systems (ADAS) such as lane departure warning or adaptive cruise control, are one of the most promising ways to improve traffic safety. By the use of computer vision, cameras working either in the visible or infra-red spectra have been demonstrated as a reliable sensor to perform this task. Nevertheless, the variability of human's appearance, not only in

  2. Preliminary Validation and Verification Plan for CAREM Reactor Protection System

    International Nuclear Information System (INIS)

    Fittipaldi, Ana; Maciel Felix

    2000-01-01

    The purpose of this paper, is to present a preliminary validation and verification plan for a particular architecture proposed for the CAREM reactor protection system with software modules (computer based system).These software modules can be either own design systems or systems based in commercial modules such as programmable logic controllers (PLC) redundant of last generation.During this study, it was seen that this plan can also be used as a validation and verification plan of commercial products (COTS, commercial off the shelf) and/or smart transmitters.The software life cycle proposed and its features are presented, and also the advantages of the preliminary validation and verification plan

  3. Container lid gasket protective strip for double door transfer system

    Science.gov (United States)

    Allen, Jr., Burgess M

    2013-02-19

    An apparatus and a process for forming a protective barrier seal along a "ring of concern" of a transfer container used with double door systems is provided. A protective substrate is supplied between a "ring of concern" and a safety cover in which an adhesive layer of the substrate engages the "ring of concern". A compressive foam strip along an opposite side of the substrate engages a safety cover such that a compressive force is maintained between the "ring of concern" and the adhesive layer of the substrate.

  4. The sustainability of the pay-as-you-go system with falling birth rates

    NARCIS (Netherlands)

    van Praag, B.M.S.; Cardoso, P.

    2002-01-01

    A model is presented that explains the mix between funded and unfunded pension systems. It turns out that total pension and the relative shares of the two systems may be explained and are determined by the population growth rate, technological growth, the time-preference discount rate, the relative

  5. Multi Agent System Based Adaptive Protection for Dispersed Generation Integrated Distribution Systems

    DEFF Research Database (Denmark)

    Liu, Leo; Rather, Zakir Hussain; Bak, Claus Leth

    2013-01-01

    of allowing islanded operation of distribution systems necessitates the adoption of adaptive protection methods for distribution systems. In order to improve the reliability and selectivity of protection for such kind of distribution systems, a coordinative adaptive protection based on multi agent system (MAS......The increasing penetration of dispersed generation (DG) brings challenges to conventional protection approaches of distribution system, mainly due to bi-directional power flow and variable fault current contribution from different generation technology-based DG units. Moreover, the trend......) is proposed. The adaptive protection intelligently adopts suitable settings for the variation of fault current from diversified DG units. Furthermore, the structure of mobile MAS with additional flexibility is capable of adapting the changes of system topology in a short period, e.g. radial/meshed, grid...

  6. Marine Protected Dramas: The Flaws of the Brazilian National System of Marine Protected Areas

    Science.gov (United States)

    Gerhardinger, Leopoldo C.; Godoy, Eduardo A. S.; Jones, Peter J. S.; Sales, Gilberto; Ferreira, Beatrice P.

    2011-04-01

    This article discusses the current problems and issues associated with the implementation of a National System of Marine Protected Areas in Brazil. MPA managers and higher governmental level authorities were interviewed about their perceptions of the implementation of a national MPA strategy and the recent changes in the institutional arrangement of government marine conservation agencies. Interviewees' narratives were generally pessimistic and the National System was perceived as weak, with few recognizable marine conservation outcomes on the ground. The following major flaws were identified: poor inter-institutional coordination of coastal and ocean governance; institutional crisis faced by the national government marine conservation agency; poor management within individual MPAs; problems with regional networks of marine protected areas; an overly bureaucratic management and administrative system; financial shortages creating structural problems and a disconnect between MPA policy and its delivery. Furthermore, a lack of professional motivation and a pessimistic atmosphere was encountered during many interviews, a malaise which we believe affects how the entire system is able to respond to crises. Our findings highlight the need for a better understanding of the role of `leadership' in the performance of socio-ecological systems (such as MPA networks), more effective official evaluation mechanisms, more localized audits of (and reforms if necessary to) Brazil's federal biodiversity conservation agency (ICMBio), and the need for political measures to promote state leadership and support. Continuing to focus on the designation of more MPAs whilst not fully addressing these issues will achieve little beyond fulfilling, on paper, Brazil's international marine biodiversity commitments.

  7. Exercise protects the cardiovascular system: effects beyond traditional risk factors.

    Science.gov (United States)

    Joyner, Michael J; Green, Daniel J

    2009-12-01

    In humans, exercise training and moderate to high levels of physical activity are protective against cardiovascular disease. In fact they are 40% more protective than predicted based on the changes in traditional risk factors (blood lipids, hypertension, diabetes etc.) that they cause. In this review, we highlight the positive effects of exercise on endothelial function and the autonomic nervous system. We also ask if these effects alone, or in combination, might explain the protective effects of exercise against cardiovascular disease that appear to be independent of traditional risk factor modification. Our goal is to use selected data from our own work and that of others to stimulate debate on the nature and cause of the 'risk factor gap' associated with exercise and physical activity.

  8. Lightning protection of flap system for wind turbine blades

    DEFF Research Database (Denmark)

    Candela Garolera, Anna; Madsen, Søren Find

    The aim of this PhD project was to investigate the behaviour of a Controllable Rubber Trailing Edge Flap (CRTEF) in a wind turbine blade when it is exposed to lightning discharges, and find the best technical solution to protect the CRTEF and the controlling system against lightning, based......, the current transmission, including the study of the induced electromagnetic fields, and the effects of degradation of the flap material due to the exposure to the lightning high electric fields. The main tools for this analysis were the simulation by the finite elements method and testing in the high voltage......, as well as general the general principles of lightning protection and the experience acquired in the analysis of lightning damages in field performed during the PhD, were the base for the design and validation of an vi effective and reliable lightning protection for the flap. Regarding the design...

  9. Real-time information and processing system for radiation protection

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, M.; Badea, E.; Guta, V.

    1999-01-01

    The real-time information and processing system has as main task to record, collect, process and transmit the radiation level and weather data, being proposed for radiation protection, environmental monitoring around nuclear facilities and for civil defence. Such a system can offer information in order to provide mapping, data base, modelling and communication and to assess the consequences of nuclear accidents. The system incorporates a number of stationary or mobile radiation monitoring equipment, weather parameter measuring station, a GIS-based information processing center and the communication network, all running on a real-time operating system. It provides the automatic data collection on-line and off-line, remote diagnostic, advanced presentation techniques, including a graphically oriented executive support, which has the ability to respond to an emergency by geographical representation of the hazard zones on the map.The system can be integrated into national or international environmental monitoring systems, being based on local intelligent measuring and transmission units, simultaneous processing and data presentation using a real-time operating system for PC and geographical information system (GIS). Such an integrated system is composed of independent applications operating under the same computer, which is capable to improve the protection of the population and decision makers efforts, updating the remote GIS data base. All information can be managed directly from the map by multilevel data retrieving and presentation by using on-line dynamic evolution of the events, environment information, evacuation optimization, image and voice processing

  10. Human Threat Management Systems: Self-Protection and Disease Avoidance

    Science.gov (United States)

    Neuberg, Steven L.; Kenrick, Douglas T.; Schaller, Mark

    2010-01-01

    Humans likely evolved precautionary systems designed to minimize the threats to reproductive fitness posed by highly interdependent ultrasociality. A review of research on the self-protection and disease avoidance systems reveals that each system is functionally distinct and domain-specific: Each is attuned to different cues; engages different emotions, inferences, and behavioral inclinations; and is rooted in somewhat different neurobiological substrates. These systems share important features, however. Each system is functionally coherent, in that perceptual, affective, cognitive, and behavioral processes work in concert to reduce fitness costs of potential threats. Each system is biased in a risk-averse manner, erring toward precautionary responses even when available cues only heuristically imply threat. And each system is functionally flexible, being highly sensitive to specific ecological and dispositional cues that signal greater vulnerability to the relevant threat. These features characterize a general template useful for understanding not only the self-protection and disease avoidance systems, but also a broader set of evolved, domain-specific precautionary systems. PMID:20833199

  11. Testing methodology of embedded software in digital plant protection system

    International Nuclear Information System (INIS)

    Seong, Ah Young; Choi, Bong Joo; Lee, Na Young; Hwang, Il Soon

    2001-01-01

    It is necessary to assure the reliability of software in order to digitalize RPS(Reactor Protection System). Since RPS causes fatal damage on accidental cases, it is classified as Safety 1E class. Therefore we propose the effective testing methodology to assure the reliability of embedded software in the DPPS(Digital Plant Protection System). To test the embedded software effectively in DPPS, our methodology consists of two steps. The first is the re-engineering step that extracts classes from structural source program, and the second is the level of testing step which is composed of unit testing, Integration Testing and System Testing. On each testing step we test the embedded software with selected test cases after the test item identification step. If we use this testing methodology, we can test the embedded software effectively by reducing the cost and the time

  12. Protection of Distribution Systems with Distributed Energy Resources

    DEFF Research Database (Denmark)

    Bak-Jensen, Birgitte; Browne, Matthew; Calone, Roberto

    The usage of Distributed Energy Resources (DER) in utilities around the world is expected to increase significantly. The existing distribution systems have been generally designed for unidirectional power flow, and feeders are opened and locked out for any fault within. However, in the future...... this practice may lead to a loss of significant generation where each feeder may have significant DER penetration. Also, utilities have started to investigate islanding operation of distribution systems with DER as a way to improve the reliability of the power supply to customers. This report is the result...... of 17 months of work of the Joint Working Group B5/C6.26/CIRED “Protection of Distribution Systems with Distributed Energy Resources”. The working group used the CIGRE report TB421 “The impact of Renewable Energy Sources and Distributed Generation on Substation Protection and Automation”, published...

  13. The role of ATP-sensitive potassium channels in cellular function and protection in the cardiovascular system.

    Science.gov (United States)

    Tinker, Andrew; Aziz, Qadeer; Thomas, Alison

    2014-01-01

    ATP-sensitive potassium channels (K(ATP)) are widely distributed and present in a number of tissues including muscle, pancreatic beta cells and the brain. Their activity is regulated by adenine nucleotides, characteristically being activated by falling ATP and rising ADP levels. Thus, they link cellular metabolism with membrane excitability. Recent studies using genetically modified mice and genomic studies in patients have implicated K(ATP) channels in a number of physiological and pathological processes. In this review, we focus on their role in cellular function and protection particularly in the cardiovascular system. © 2013 The British Pharmacological Society.

  14. 78 FR 66384 - Membership of the Merit Systems Protection Board's Performance Review Board

    Science.gov (United States)

    2013-11-05

    ... MERIT SYSTEMS PROTECTION BOARD Membership of the Merit Systems Protection Board's Performance Review Board AGENCY: Merit Systems Protection Board. ACTION: Notice. SUMMARY: Notice is hereby given of the members of the Merit Systems Protection Board's Performance Review Board. DATES: November 5, 2013...

  15. 76 FR 42140 - Public Availability of the Merit Systems Protection Board's FY 2010 Service Contract Inventory

    Science.gov (United States)

    2011-07-18

    ... From the Federal Register Online via the Government Publishing Office MERIT SYSTEMS PROTECTION BOARD Public Availability of the Merit Systems Protection Board's FY 2010 Service Contract Inventory AGENCY: Merit Systems Protection Board. ACTION: Notice. SUMMARY: The Merit Systems Protection Board (MSPB...

  16. 78 FR 49479 - Updates to List of National System of Marine Protected Areas MPAs

    Science.gov (United States)

    2013-08-14

    ... System of Marine Protected Areas MPAs AGENCY: National Marine Protected Areas Center (MPA Center), Office... Marine Protected Areas (MPAs). SUMMARY: The National System of Marine Protected Areas (MPAs) provides a... Protected Areas Center (MPA Center). The managing agencies listed above were then asked to make a final...

  17. Sensorbased fall detection and fall prediction of senior citizens in their domestic environment

    OpenAIRE

    Feldwieser, Florian

    2015-01-01

    Introduction: Falls in old age are associated with a reduction of autonomy and mobility and are one the main threads to the health of older adults. Physical and mental consequences of falls are a large financial burden to the healthcare system. Automatic fall detection devices could call of medical help in case of a fall and fall prevention programmers could specifically address the deficits of persons at risk of falling. Currently it is difficult and expensive to correctly identify perso...

  18. Advanced Control and Protection system Design Methods for Modular HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    Ball, Sydney J [ORNL; Wilson Jr, Thomas L [ORNL; Wood, Richard Thomas [ORNL

    2012-06-01

    The project supported the Nuclear Regulatory Commission (NRC) in identifying and evaluating the regulatory implications concerning the control and protection systems proposed for use in the Department of Energy's (DOE) Next-Generation Nuclear Plant (NGNP). The NGNP, using modular high-temperature gas-cooled reactor (HTGR) technology, is to provide commercial industries with electricity and high-temperature process heat for industrial processes such as hydrogen production. Process heat temperatures range from 700 to 950 C, and for the upper range of these operation temperatures, the modular HTGR is sometimes referred to as the Very High Temperature Reactor or VHTR. Initial NGNP designs are for operation in the lower temperature range. The defining safety characteristic of the modular HTGR is that its primary defense against serious accidents is to be achieved through its inherent properties of the fuel and core. Because of its strong negative temperature coefficient of reactivity and the capability of the fuel to withstand high temperatures, fast-acting active safety systems or prompt operator actions should not be required to prevent significant fuel failure and fission product release. The plant is designed such that its inherent features should provide adequate protection despite operational errors or equipment failure. Figure 1 shows an example modular HTGR layout (prismatic core version), where its inlet coolant enters the reactor vessel at the bottom, traversing up the sides to the top plenum, down-flow through an annular core, and exiting from the lower plenum (hot duct). This research provided NRC staff with (a) insights and knowledge about the control and protection systems for the NGNP and VHTR, (b) information on the technologies/approaches under consideration for use in the reactor and process heat applications, (c) guidelines for the design of highly integrated control rooms, (d) consideration for modeling of control and protection system designs

  19. Routine testing on protective and safety systems and components

    International Nuclear Information System (INIS)

    Rysy, W.

    1977-01-01

    1) In-process inspection, tests during commissioning. 2) Tests during reactor operation. 2.1) Reactor protection system, for example: continuous auto-testing by a dynamic system, check of the output signals; 2.2) safety features: selected examples: functional tests on the ECCS, trial operation of the emergency diesels. 3) Tests during refuelling phase. 3.1) Containment: Leakage rate tests, leak testing; 3.2) coolant system: selected examples: inservice inspections of the pressure vessel, eddy current testing of the steam generator, functional tests of safety valves. (orig./HP) [de

  20. Hybrid Plasma Reactor/Filter for Transportable Collective Protection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Josephson, Gary B.; Tonkyn, Russell G.; Frye, J. G.; Riley, Brian J.; Rappe, Kenneth G.

    2011-04-06

    Pacific Northwest National Laboratory (PNNL) has performed an assessment of a Hybrid Plasma/Filter system as an alternative to conventional methods for collective protection. The key premise of the hybrid system is to couple a nonthermal plasma (NTP) reactor with reactive adsorption to provide a broader envelope of protection than can be provided through a single-solution approach. The first step uses highly reactive species (e.g. oxygen radicals, hydroxyl radicals, etc.) created in a nonthermal plasma (NTP) reactor to destroy the majority (~75% - 90%) of an incoming threat. Following the NTP reactor an O3 reactor/filter uses the O3 created in the NTP reactor to further destroy the remaining organic materials. This report summarizes the laboratory development of the Hybrid Plasma Reactor/Filter to protect against a ‘worst-case’ simulant, methyl bromide (CH3Br), and presents a preliminary engineering assessment of the technology to Joint Expeditionary Collective Protection performance specifications for chemical vapor air purification technologies.

  1. Designing and evaluating an electronic patient falls reporting system: perspectives for the implementation of health information technology in long-term residential care facilities.

    Science.gov (United States)

    Mei, Yi You; Marquard, Jenna; Jacelon, Cynthia; DeFeo, Audrey L

    2013-11-01

    Patient falls are the leading cause of unintentional injury and death among older adults. In 2000, falls resulted in over 10,300 elderly deaths, costing the United States approximately $179 million in incidence and medical costs. Furthermore, non-fatal injuries caused by falls cost the United States $19 billion annually. Health information technology (IT) applications, specifically electronic falls reporting systems, can aid quality improvement efforts to prevent patient falls. Yet, long-term residential care facilities (LTRCFs) often do not have the financial resources to implement health IT, and workers in these settings are often not ready to adopt such systems. Additionally, most health IT evaluations are conducted in large acute-care settings, so LTRCF administrators currently lack evidence to support the value of health IT. In this paper, we detail the development of a novel, easy-to-use system to facilitate electronic patient falls reporting within a LTRCF using off-the-shelf technology that can be inexpensively implemented in a wide variety of settings. We report the results of four complimentary system evaluation measures that take into consideration varied organizational stakeholders' perspectives: (1) System-level benefits and costs, (2) system usability, via scenario-based use cases, (3) a holistic assessment of users' physical, cognitive, and marcoergonomic (work system) challenges in using the system, and (4) user technology acceptance. We report the viability of collecting and analyzing data specific to each evaluation measure and detail the relative merits of each measure in judging whether the system is acceptable to each stakeholder. The electronic falls reporting system was successfully implemented, with 100% reporting at 3-months post-implementation. The system-level benefits and costs approach showed that the electronic system required no initial investment costs aside from personnel costs and significant benefits accrued from user time savings

  2. Multi Agent System Based Wide Area Protection against Cascading Events

    DEFF Research Database (Denmark)

    Liu, Zhou; Chen, Zhe; Liu, Leo

    2012-01-01

    In this paper, a multi-agent system based wide area protection scheme is proposed in order to prevent long term voltage instability induced cascading events. The distributed relays and controllers work as a device agent which not only executes the normal function automatically but also can be mod...... the effectiveness of proposed protection strategy. The simulation results indicate that the proposed multi agent control system can effectively coordinate the distributed relays and controllers to prevent the long term voltage instability induced cascading events.......In this paper, a multi-agent system based wide area protection scheme is proposed in order to prevent long term voltage instability induced cascading events. The distributed relays and controllers work as a device agent which not only executes the normal function automatically but also can...... be modified to fulfill the extra function according to external requirements. The control center is designed as a highest level agent in MAS to coordinate all the lower agents to prevent the system wide voltage disturbance. A hybrid simulation platform with MATLAB and RTDS is set up to demonstrate...

  3. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  4. Psychotropic Medication Use among Children in the Child Welfare System. Issue Brief No. 59, Fall 2012

    Science.gov (United States)

    Walsh, Wendy A.; Mattingly, Marybeth J.

    2012-01-01

    Prior research demonstrates that children in the child welfare system are given psychotropic medication at rates approximately three times higher than children and adolescents in the general population. Using data from the second National Survey of Child and Adolescent Well-Being, authors Wendy Walsh and Marybeth Mattingly report that among…

  5. Safety evaluation of the KNICS digital reactor protection system

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Jang, Seung Cheol; Choi, Jong Gyun

    2005-01-01

    Korean Nuclear I and C System (KNICS) project, a national research program for developing a safety-class digital system, has designed a new reactor protection system (RPS). The usage of digital equipment in a safety critical application increases the importance of a risk evaluation since microprocessors and software technologies make the digital system very complex and their unavailability is hard to quantify. This paper addresses the safety evaluation of the KNICS RPS in consideration of the several technical concerns of a safety modeling for a digital system. We also present the fault-tree modeling technique and the risk evaluation results. A fault-tree model which includes the common cause failure events, the coverage of a fault-tolerant mechanism and the software failure event is developed. Based on the minimal cut sets of the model, we discuss the system unavailability of the newly developed design of the KNICS RPS

  6. Plutonium Protection System (PPS). Volume 2. Hardware description. Final report

    International Nuclear Information System (INIS)

    Miyoshi, D.S.

    1979-05-01

    The Plutonium Protection System (PPS) is an integrated safeguards system developed by Sandia Laboratories for the Department of Energy, Office of Safeguards and Security. The system is designed to demonstrate and test concepts for the improved safeguarding of plutonium. Volume 2 of the PPS final report describes the hardware elements of the system. The major areas containing hardware elements are the vault, where plutonium is stored, the packaging room, where plutonium is packaged into Container Modules, the Security Operations Center, which controls movement of personnel, the Material Accountability Center, which maintains the system data base, and the Material Operations Center, which monitors the operating procedures in the system. References are made to documents in which details of the hardware items can be found

  7. FAULT-TOLERANT DESIGN FOR ADVANCED DIVERSE PROTECTION SYSTEM

    Directory of Open Access Journals (Sweden)

    YANG GYUN OH

    2013-11-01

    Full Text Available For the improvement of APR1400 Diverse Protection System (DPS design, the Advanced DPS (ADPS has recently been developed to enhance the fault tolerance capability of the system. Major fault masking features of the ADPS compared with the APR1400 DPS are the changes to the channel configuration and reactor trip actuation equipment. To minimize the fault occurrences within the ADPS, and to mitigate the consequences of common-cause failures (CCF within the safety I&C systems, several fault avoidance design features have been applied in the ADPS. The fault avoidance design features include the changes to the system software classification, communication methods, equipment platform, MMI equipment, etc. In addition, the fault detection, location, containment, and recovery processes have been incorporated in the ADPS design. Therefore, it is expected that the ADPS can provide an enhanced fault tolerance capability against the possible faults within the system and its input/output equipment, and the CCF of safety systems.

  8. Multiagent based protection and control in decentralized electric power systems

    DEFF Research Database (Denmark)

    Saleem, Arshad; Lind, Morten; Veloso, Manuela

    2010-01-01

    Electric power systems are going through a major change both in their physical and control structure. A large num- ber of small and geographically dispersed power generation units (e.g., wind turbines, solar cells, plug-in electric cars) are replacing big centralized power plants. This shift has...... created interesting possibilities for application of intelligent systems such as multiagent systems for control and automation in electric power systems. This paper describes work on designing a multiagent system for protection and control of electric power distribution networks.It demonstrates how...... explicit modeling of capabilities, states, roles and role transition in agents can capture the control and automation in electric power systems. We present illustrative results from using our proposed schema in realistic simulations....

  9. A privacy protection for an mHealth messaging system

    Science.gov (United States)

    Aaleswara, Lakshmipathi; Akopian, David; Chronopoulos, Anthony T.

    2015-03-01

    In this paper, we propose a new software system that employs features that help the organization to comply with USA HIPAA regulations. The system uses SMS as the primary way of communication to transfer information. Lack of knowledge about some diseases is still a major reason for some harmful diseases spreading. The developed system includes different features that may help to communicate amongst low income people who don't even have access to the internet. Since the software system deals with Personal Health Information (PHI) it is equipped with an access control authentication system mechanism to protect privacy. The system is analyzed for performance to identify how much overhead the privacy rules impose.

  10. Protective systems and its protective switching elements on local failures of large slow-capacitor bank system

    International Nuclear Information System (INIS)

    Hasegawa, Mitsuo; Inoue, Kunikazu; Ueno, Isao.

    1994-01-01

    In various applications of pulsed power technologies, large capacitor bank systems are used to feed high current impulse to different experimental devices. The accidental electric breakdown in one of the capacitors in a parallel connection of the large bank may result in serious damages such as mechanical explosion and oil effusion or fire. In most fast banks, each unit capacitor has an output gap switch, which is expected to decouple the capacitors one another. However, no such special element is adopted usually in the slow bank system, partly because of the economical consideration. We have developed a novel and inexpensive protective element for these relatively slow capacitor banks, utilizing a concept of the enclosed type of the fast breakers. The principle of the operation of the protection elements is verified by a simulation experiment. Their practical effectiveness is also successfully demonstrated in the application to the system of the pulsed high magnetic field generator. (author)

  11. Development and qualification of engineering prototype of digital protection system

    International Nuclear Information System (INIS)

    Huang Xiaojin; Zhang Liangju; Shi Mingde; Li Duo

    2005-01-01

    The digital technology was adopted in the development of protection system for an in-construction research reactor. In order to demonstrate that the design scheme can be able to meet all the function and performance requirements from the project, and qualify requirements constrained by the regulations, a 1:1 engineering prototype of the digital RPS was developed. And then the prototype has passed all the function and performance test, the stated items of qualification, and round-the-clock teat. This paper describes the digital protection system's design scheme, the scale and development process of engineering prototype, the approaches of qualification, and the method of round-the-clock test. The test results indicate that the engineering prototype has fully achieved the preconcerted performance index and reliability requirement. (authors)

  12. Protective and Pathological Immunity during Central Nervous System Infections.

    Science.gov (United States)

    Klein, Robyn S; Hunter, Christopher A

    2017-06-20

    The concept of immune privilege of the central nervous system (CNS) has dominated the study of inflammatory processes in the brain. However, clinically relevant models have highlighted that innate pathways limit pathogen invasion of the CNS and adaptive immunity mediates control of many neural infections. As protective responses can result in bystander damage, there are regulatory mechanisms that balance protective and pathological inflammation, but these mechanisms might also allow microbial persistence. The focus of this review is to consider the host-pathogen interactions that influence neurotropic infections and to highlight advances in our understanding of innate and adaptive mechanisms of resistance as key determinants of the outcome of CNS infection. Advances in these areas have broadened our comprehension of how the immune system functions in the brain and can readily overcome immune privilege. Copyright © 2017. Published by Elsevier Inc.

  13. Protecting sensitive systems and data in an open agency

    Science.gov (United States)

    Hunt, Douglas B.; Tompkins, Frederick G.

    1987-01-01

    This paper focuses on the policy and definitional issues associated with providing adequate and reasonable levels of protection for sensitive systems and data in an agency whose basic charter mandates the open sharing of information and transfer of technology into the market economy. An information model based on current Federal regulatory issuances is presented. A scheme for determining sensitivity levels, based on a categorization taxonomy,is provided.

  14. Regional views on the new system of radiological protection

    International Nuclear Information System (INIS)

    Yoda, N.; Fujimoto, K.; Miyamaru, K.; Lee, J.; Loy, J.; Pan, Z.Q.

    2005-01-01

    This document takes stock on the second session of the second Asian regional conference. In this session, japanese regulators, researchers and operators presented their regional views on the new ICRP recommendations. It was commonly expressed that an understanding of the background to the introduced concepts in the new recommendations is required. Other regional views from Korea, Australia and China were also expressed, based on their own regulatory system and referring to radiological protection topics in their countries. (A.L.B.)

  15. Frequency loss induced quench protection system for high temperature superconductors

    Science.gov (United States)

    Ijagbemi, K.; Noyes, P.; Stiers, E.; Pamidi, S.

    2017-12-01

    A novel circuit design for Frequency Loss Induced Quench (FLIQ) protection system for safely driving REBCO coated conductor superconducting coils to quench is reported. The details of the H-bridge circuit design with Insulated Gate Bipolar Transistor (IGBT)s and the various elements used to build a prototype are reported. The results of a successful test of the circuit conducted to demonstrate the validity of the circuit design is presented.

  16. Engineering Aerothermal Analysis for X-34 Thermal Protection System Design

    Science.gov (United States)

    Wurster, Kathryn E.; Riley, Christopher J.; Zoby, E. Vincent

    1998-01-01

    Design of the thermal protection system for any hypersonic flight vehicle requires determination of both the peak temperatures over the surface and the heating-rate history along the flight profile. In this paper, the process used to generate the aerothermal environments required for the X-34 Testbed Technology Demonstrator thermal protection system design is described as it has evolved from a relatively simplistic approach based on engineering methods applied to critical areas to one of detailed analyses over the entire vehicle. A brief description of the trajectory development leading to the selection of the thermal protection system design trajectory is included. Comparisons of engineering heating predictions with wind-tunnel test data and with results obtained using a Navier-Stokes flowfield code and an inviscid/boundary layer method are shown. Good agreement is demonstrated among all these methods for both the ground-test condition and the peak heating flight condition. Finally, the detailed analysis using engineering methods to interpolate the surface-heating-rate results from the inviscid/boundary layer method to predict the required thermal environments is described and results presented.

  17. Stormwater quality of spring-summer-fall effluent from three partial-infiltration permeable pavement systems and conventional asphalt pavement.

    Science.gov (United States)

    Drake, Jennifer; Bradford, Andrea; Van Seters, Tim

    2014-06-15

    This study examined the spring, summer and fall water quality performance of three partial-infiltration permeable pavement (PP) systems and a conventional asphalt pavement in Ontario. The study, conducted between 2010 and 2012, compared the water quality of effluent from two Interlocking Permeable Concrete Pavements (AquaPave(®) and Eco-Optiloc(®)) and a Hydromedia(®) Pervious Concrete pavement with runoff from an Asphalt control pavement. The usage of permeable pavements can mitigate the impact of urbanization on receiving surface water systems through quantity control and stormwater treatment. The PP systems provided excellent stormwater treatment for petroleum hydrocarbons, total suspended solids, metals (copper, iron, manganese and zinc) and nutrients (total-nitrogen and total-phosphorus) by reducing event mean concentrations (EMC) as well as total pollutant loadings. The PPs significantly reduced the concentration and loading of ammonia (NH4(+)+NH3), nitrite (NO2(-)) and organic-nitrogen (Org-N) but increased the concentration and loading of nitrate (NO3(-)). The PP systems had mixed performances for the treatment of phosphate (PO4(3-)). The PP systems increased the concentration of sodium (Na) and chloride (Cl) but EMCs remained well below recommended levels for drinking water quality. Relative to the observed runoff, winter road salt was released more slowly from the PP systems resulting in elevated spring and early-summer Cl and Na concentrations in effluent. PP materials were found to introduce dissolved solids into the infiltrating stormwater. The release of these pollutants was verified by additional laboratory scale testing of the individual pavement and aggregate materials at the University of Guelph. Pollutant concentrations were greatest during the first few months after construction and declined rapidly over the course of the study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Physical Protection System Upgrades - Optimizing for Performance and Cost

    International Nuclear Information System (INIS)

    Hicks, Mary Jane; Bouchard, Ann M.

    1999-01-01

    CPA--Cost and Performance Analysis--is an architecture that supports analysis of physical protection systems and upgrade options. ASSESS (Analytic System and Software for Evaluating Security Systems), a tool for evaluating performance of physical protection systems, currently forms the cornerstone for evaluating detection probabilities and delay times of the system. Cost and performance data are offered to the decision-maker at the systems level and to technologists at the path-element level. A new optimization engine has been attached to the CPA methodology to automate analyses of many combinations (portfolios) of technologies. That engine controls a new analysis sequencer that automatically modifies ASSESS PPS files (facility descriptions), automatically invokes ASSESS Outsider analysis and then saves results for post-processing. Users can constrain the search to an upper bound on total cost, to a lower bound on level of performance, or to include specific technologies or technology types. This process has been applied to a set of technology development proposals to identify those portfolios that provide the most improvement in physical security for the lowest cost to install, operate and maintain at a baseline facility

  19. Physical Protection System Upgrades - Optimizing for Performance and Cost

    Energy Technology Data Exchange (ETDEWEB)

    Bouchard, Ann M.; Hicks, Mary Jane

    1999-07-09

    CPA--Cost and Performance Analysis--is an architecture that supports analysis of physical protection systems and upgrade options. ASSESS (Analytic System and Software for Evaluating Security Systems), a tool for evaluating performance of physical protection systems, currently forms the cornerstone for evaluating detection probabilities and delay times of the system. Cost and performance data are offered to the decision-maker at the systems level and to technologists at the path-element level. A new optimization engine has been attached to the CPA methodology to automate analyses of many combinations (portfolios) of technologies. That engine controls a new analysis sequencer that automatically modifies ASSESS PPS files (facility descriptions), automatically invokes ASSESS Outsider analysis and then saves results for post-processing. Users can constrain the search to an upper bound on total cost, to a lower bound on level of performance, or to include specific technologies or technology types. This process has been applied to a set of technology development proposals to identify those portfolios that provide the most improvement in physical security for the lowest cost to install, operate and maintain at a baseline facility.

  20. Protection study of a diagnostic system for electron beam at the output of an accelerator

    International Nuclear Information System (INIS)

    Rahmani, Kaouther; Yaacoubi, Imen

    2009-01-01

    The aim of this work is the determination of the conception of a protection system dedicated to protect a diagnostic system in the CNSTN. According to this study, the suitable material for the protection against the electrons in the plexiglas and the supermalloy to protect the future diagnostic system against the magnetic field. (Author)

  1. "My older clients fall through every crack in the system": geriatrics knowledge of legal professionals.

    Science.gov (United States)

    Soones, Tacara; Ahalt, Cyrus; Garrigues, Sarah; Faigman, David; Williams, Brie A

    2014-04-01

    With the number of older adult arrestees and prisoners increasing rapidly, legal professionals increasingly provide front-line identification and response to age-related health conditions (including cognitive and physical impairments) that may affect legal outcomes, such as the ability to participate in one's defense or stay safe in jail. The goals of this study were to assess the ability of legal professionals to recognize and respond to age-related conditions that could affect legal outcomes and to identify recommendations to address important knowledge gaps. This was a mixed quantitative-qualitative study. Legal professionals (N = 72) in the criminal justice system were surveyed to describe their demographic characteristics, expertise, and prior aging-related training and to inform the qualitative interview guide. Those surveyed included attorneys (district attorneys (25%), public defenders and legal advocates (58%)), judges (6%), and court-affiliated social workers (11%). In-depth qualitative interviews were then conducted with a subset of 10 legal professionals who worked with older adults at least weekly. Results from the surveys and interviews revealed knowledge deficits in four important areas: age-related health, identification of cognitive impairment, assessment of safety risk, and optimization of services upon release from jail. Four recommendations to close these gaps emerged: educate legal professionals about age-related health, train professionals to identify cognitive and sensory impairment, develop checklists to identify those at risk of poor health or safety, and improve knowledge of and access to transitional services for older adults. These findings suggest that geriatrics knowledge gaps of legal professionals exist that may contribute to adverse medical or legal outcomes for older adults involved in the criminal justice system and that partnerships between healthcare and legal professionals are needed to address these challenges. © Published

  2. Safety aspect of digital reactor protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Zen-Ichi

    1998-01-01

    It was early in 1980's that the digital controllers were first applied to nuclear power plant in japan. After that, their application area had been expanding gradually, reaching to the overall integrated digital system including the safety system in Kashiwazaki-Kariwa units 6 and 7. The software for computer-based systems has been produced using the graphical language ''POL'' in Japanese nuclear power plants. It is the fundamental principle that the reliability of the software should be assured through the properly managed quality assurance. The POL-based system is fitted to this principle. In applying POL-based systems to safety system, the MITI, Ministry of International Trade and Industry, identified the licensing issues as the regulatory body, while the utilities had developed the digital technology feasible to the safety application. Through the activities, a specific industrial design guide for the software important to safety was established and the adequacy of the technology was certified through the demonstration tests of the integrated system. In the safety examination of the digital reactor protection system of K-6/7, the application of POL were approved. The POL-based systems in nuclear power plants were successful design and production process of the POL-based systems. This paper describes the activities in licensing and maintaining the computer-based systems by the utilities and manufacturers as well as the MITI. (author)

  3. In-Space Repair of Reinforced Carbon-Carbon (RCC) Thermal Protection System Structures

    Science.gov (United States)

    Singh, Mrityunjay

    2005-01-01

    Advanced repair and refurbishment technologies are critically needed for the RCC-based thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate adhesives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, PLASTER (Patch Laminates and Sealant Technology for Exterior Repair) based systems have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  4. In-Space Repair of Reinforced Carbon-Carbon Thermal Protection System Structures

    Science.gov (United States)

    Singh, Mrityunjay

    2006-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, integrated system for tile and leading edge repair (InSTALER) have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  5. Model Based Cyber Security Analysis for Research Reactor Protection System

    International Nuclear Information System (INIS)

    Sho, Jinsoo; Rahman, Khalil Ur; Heo, Gyunyoung; Son, Hanseong

    2013-01-01

    The study on the qualitative risk due to cyber-attacks into research reactors was performed using bayesian Network (BN). This was motivated to solve the issues of cyber security raised due to digitalization of instrumentation and control (I and C) system. As a demonstrative example, we chose the reactor protection system (RPS) of research reactors. Two scenarios of cyber-attacks on RPS were analyzed to develop mitigation measures against vulnerabilities. The one is the 'insertion of reactor trip' and the other is the 'scram halt'. The six mitigation measures are developed for five vulnerability for these scenarios by getting the risk information from BN

  6. Report on the performance monitoring system for the interim waste containment at the Niagara Falls Storage Site, Lewiston, New York

    Energy Technology Data Exchange (ETDEWEB)

    1985-10-01

    The Niagara Falls Storage Site (NFSS) is an interim storage site for low-level radioactive waste, established by the US Department of Energy (DOE) at Lewiston, New York. The waste containment structure for encapsulating low-level radioactive waste at the NFSS has been designed to minimize infiltration of rainfall, prevent pollution of groundwater, preclude formation of leachate, and prevent radon emanation. Accurately determining the performance of the main engineered elements of the containment structure will be important in establishing confidence in the ability of the structure to retain the wastes. For this purpose, a waste containment performance monitoring system has been developed to verify that these elements are functioning as intended. The key objective of the performance monitoring system is the early detection of trends that could be indicative of weaknesses developing in the containment structure so that corrective action can be taken before the integrity of the structure is compromised. Consequently, subsurface as well as surface monitoring techniques will be used. After evaluating several types of subsurface instrumentation, it was determined that vibrating wire pressure transducers, in combination with surface monitoring techniques, would satisfactorily monitor the parameters of concern, such as water accumulation inside the containment facility, waste settlement, and shrinkage of the clay cover. Surface monitoring will consist of topographic surveys based on predetermined gridlines, walkover surveys, and aerial photography to detect vegetative stress or other changes not evident at ground level. This report details the objectives of the performance monitoring system, identifies the elements of the containment design whose performance will be monitored, describes the monitoring system recommended, and outlines the costs associated with the monitoring system. 5 refs., 4 figs., 3 tabs.

  7. Report on the performance monitoring system for the interim waste containment at the Niagara Falls Storage Site, Lewiston, New York

    International Nuclear Information System (INIS)

    1985-10-01

    The Niagara Falls Storage Site (NFSS) is an interim storage site for low-level radioactive waste, established by the US Department of Energy (DOE) at Lewiston, New York. The waste containment structure for encapsulating low-level radioactive waste at the NFSS has been designed to minimize infiltration of rainfall, prevent pollution of groundwater, preclude formation of leachate, and prevent radon emanation. Accurately determining the performance of the main engineered elements of the containment structure will be important in establishing confidence in the ability of the structure to retain the wastes. For this purpose, a waste containment performance monitoring system has been developed to verify that these elements are functioning as intended. The key objective of the performance monitoring system is the early detection of trends that could be indicative of weaknesses developing in the containment structure so that corrective action can be taken before the integrity of the structure is compromised. Consequently, subsurface as well as surface monitoring techniques will be used. After evaluating several types of subsurface instrumentation, it was determined that vibrating wire pressure transducers, in combination with surface monitoring techniques, would satisfactorily monitor the parameters of concern, such as water accumulation inside the containment facility, waste settlement, and shrinkage of the clay cover. Surface monitoring will consist of topographic surveys based on predetermined gridlines, walkover surveys, and aerial photography to detect vegetative stress or other changes not evident at ground level. This report details the objectives of the performance monitoring system, identifies the elements of the containment design whose performance will be monitored, describes the monitoring system recommended, and outlines the costs associated with the monitoring system. 5 refs., 4 figs., 3 tabs

  8. A development of digital plant protection system architecture

    International Nuclear Information System (INIS)

    Seong, S. H.; Park, H. Y.; Kim, D. H.; Seo, Y. S.; Gu, I. S.

    2000-01-01

    The digital plant protection system (DPPS) which have a large number of advantages compared to current analog protection system has been developed in various field. The major disadvantages of digital system are, however, vulnerable to faults of processor and software. To overcome the disadvantages, the concept of segment and partition in a channel has been developed. Each segment in a channel is divided from sensor to reactor trip and engineered safety features, which is based on the functional diversity of input signals against the various plant transient phenomena. Each partition allocates the function module to an independent processing module in order to process and isolate the faults of each module of a segment. A communication system based on the deterministic protocol with the predictable and hard real-time characteristics has been developed in order to link the various modules within a segment. The self-diagnostics including online test and periodic test procedures are developed in order to increase the safety, reliability and availability of DPPS. The developed DPPS uses the off-the-shelf DSP (digital signal processor) and adopts VME bus architecture, which have sufficient operation experience in the industry. The verification and validation and quality assurance of software has been developed and the architecture and protocol of deterministic communication system has been researched

  9. Qualification issues for advanced light-water reactor protection systems

    International Nuclear Information System (INIS)

    Korsah, K.; Clark, R.L.; Antonescu, C.

    1993-01-01

    The instrumentation and control (I ampersand C) systems in advanced reactors will make extensive use of digital controls, microprocessors, multiplexing, and fiber optic transmission. Elements of these advances in I ampersand C have been implemented on some current operating plants. However, the widespread use of the above technologies, as well as the use of artificial intelligence with minimum reliance on human operator control of reactors, highlights the need to develop standards for qualifying the I ampersand C used in the next generation of nuclear power plants. As a first step in this direction, the protection system I ampersand C for present-day plants was compared to that proposed for advanced light-water reactors (ALWRs). An evaluation template was developed by assembling a configuration of a safety channel instrument string for a generic ALWR, then comparing the impact of environmental stressors on that string to their effect on an equivalent instrument string from an existing light-water reactor. The template was then used to suggest a methodology for the qualification of microprocessor-based protection systems. The methodology identifies standards/regulatory guides (or lack thereof) for the qualification of microprocessor-based safety I ampersand C systems. This approach addresses in part issues raised in NRC policy document SECY-91-292, which recognizes that advanced I ampersand C systems for the nuclear industry are ''being developed without consensus standards. as the technology available for design is ahead of the technology that is well understood through experience and supported by application standards.''

  10. High-Level System Change: Protecting Business and Society

    Directory of Open Access Journals (Sweden)

    Frank Dixon

    2017-10-01

    Full Text Available Over the past 15 years, sustainability has become mainstream in the corporate and financial sectors. But environmental and social conditions are declining rapidly in many regions. Nearly all corporate and financial sector sustainability strategies are focused on company-level activities, such as unilaterally mitigating negative environmental and social impacts. But flawed economic and political systems make it impossible for businesses to mitigate about 80 percent of negative impacts. These impacts often return to harm companies, for example, in the form of market rejection, lawsuits and reputation damage. System change is the most important sustainability issue. Protecting business and society requires substantially shifting the focus of corporate sustainability strategies from company change to system change. A growing number of collaborative system change efforts are being implemented. Most focus on specific issues, sectors or system flaws. They frequently are ineffective because they do not use a whole system approach. All major aspects of human society are connected. Root causes, key leverage points and most effective solutions often lie outside of issue-specific areas. Climate change, economic reform and other complex issues can only be effectively addressed through a whole system approach. This paper summarizes important economic and political system flaws and describes a collaborative, whole system approach for engaging the corporate and financial sectors in system change.

  11. Investigation of the falling water flow with evaporation for the passive containment cooling system and its scaling-down criteria

    Science.gov (United States)

    Li, Cheng; Li, Junming; Li, Le

    2018-02-01

    Falling water evaporation cooling could efficiently suppress the containment operation pressure during the nuclear accident, by continually removing the core decay heat to the atmospheric environment. In order to identify the process of large-scale falling water evaporation cooling, the water flow characteristics of falling film, film rupture and falling rivulet were deduced, on the basis of previous correlation studies. The influences of the contact angle, water temperature and water flow rates on water converge along the flow direction were then numerically obtained and results were compared with the data for AP1000 and CAP1400 nuclear power plants. By comparisons, it is concluded that the water coverage fraction of falling water could be enhanced by either reducing the surface contact angle or increasing the water temperature. The falling water flow with evaporation for AP1000 containment was then calculated and the feature of its water coverage fraction was analyzed. Finally, based on the phenomena identification of falling water flow for AP1000 containment evaporation cooling, the scaling-down is performed and the dimensionless criteria were obtained.

  12. A passive solar water heating system for vineyard frost protection

    Energy Technology Data Exchange (ETDEWEB)

    Smyth, M. [Centre for Sustainable Technologies, School of the Built Environment, University of Ulster, Newtownabbey BT37 0QB (Ireland); Skates, H. [Environmental Engineering Research Centre, School of Planning, Architecture and Civil Engineering, Queen' s University, Belfast BT9 5AG (Ireland)

    2009-03-15

    The threat of frost during spring time (after 'bud burst') is an ever present danger to the vineyard owner. To minimise the risk, in addition to good site selection and vineyard management, a number of active frost protection systems are available. Most active methods of frost protection are costly in monetary terms and can also have a detrimental effect on the environment. This work presents the design and performance of a passive solar water heating quilt system under real vineyard operating conditions. Two vineyard sites were selected, and the solar water heating quilt design was evaluated over a three-month period. Detailed measurements of the temperature below and above the soil surface, levels of incident solar radiation and the wind direction and speed were recorded. Field study results indicate that the quilts can improve the solar collection and heat retention of the soil, resulting in increased temperatures during frost events of up to 1 C in air space immediately adjacent to the solar quilts when compared to conditions off the protected area. In addition, the time period during which the frost remains a danger to the vine is also reduced. When heat collection, storage and extraction rates are investigated, simplified calculations indicate that the solar quilt can improve collection by 38.5% over bare soil, resulting in the release of 32% more heat. Extrapolated to vineyard coverage, this could result in an extra 3500 MJ of heat per hectare per (typical frost event condition) day. (author)

  13. Protecting your files on the DFS file system

    CERN Multimedia

    Computer Security Team

    2011-01-01

    The Windows Distributed File System (DFS) hosts user directories for all NICE users plus many more data.    Files can be accessed from anywhere, via a dedicated web portal (http://cern.ch/dfs). Due to the ease of access to DFS with in CERN it is of utmost importance to properly protect access to sensitive data. As the use of DFS access control mechanisms is not obvious to all users, passwords, certificates or sensitive files might get exposed. At least this happened in past to the Andrews File System (AFS) - the Linux equivalent to DFS) - and led to bad publicity due to a journalist accessing supposedly "private" AFS folders (SonntagsZeitung 2009/11/08). This problem does not only affect the individual user but also has a bad impact on CERN's reputation when it comes to IT security. Therefore, all departments and LHC experiments agreed recently to apply more stringent protections to all DFS user folders. The goal of this data protection policy is to assist users in pro...

  14. Protecting your files on the AFS file system

    CERN Multimedia

    2011-01-01

    The Andrew File System is a world-wide distributed file system linking hundreds of universities and organizations, including CERN. Files can be accessed from anywhere, via dedicated AFS client programs or via web interfaces that export the file contents on the web. Due to the ease of access to AFS it is of utmost importance to properly protect access to sensitive data in AFS. As the use of AFS access control mechanisms is not obvious to all users, passwords, private SSH keys or certificates have been exposed in the past. In one specific instance, this also led to bad publicity due to a journalist accessing supposedly "private" AFS folders (SonntagsZeitung 2009/11/08). This problem does not only affect the individual user but also has a bad impact on CERN's reputation when it comes to IT security. Therefore, all departments and LHC experiments agreed in April 2010 to apply more stringent folder protections to all AFS user folders. The goal of this data protection policy is to assist users in...

  15. Evaluation of road-transit physical protection systems

    International Nuclear Information System (INIS)

    Gallagher, R.J.; Keeton, S.C.; Stimmell, K.G.; DeLaquil, P. III.

    1978-05-01

    To assess the overall effectiveness of a transportation physical protection system, computer codes which simulate armed attacks have been developed and are being used to examine a range of issues associated with road transportation systems. The paper discusses the purpose and features of three of these codes, SOURCE (which simulates the initial ambush), SABRES I (which covers the battle) and BARS (which treats the penetration of protective cargo barriers). The use of these methodologies to evaluate the value of additional vehicles, guards, armor and alternative tactics or equipment as a means of improving convoy security has recently been completed. The results which are presented demonstrate that the protection offered by the present commercial regulations for guards and vehicles is probably marginal. This could be substantially increased by the addition of armor to close escort vehicles instead of just the transporter and the use of appropriate tactics. Against the baseline threat of adversaries armed with M-16's, observation and harassment from a modest distance until re-enforcements arrive appears preferable to aggressive assault by the ambushed guard force

  16. Research on effectiveness assessment programs for physical protection system

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Janghoon; Yoo, Hosik; Ham, Taekyu [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of)

    2015-05-15

    PPS (Physical Protection System) is an integrated set of procedures, installation and human resources to protect valuable assets from physical attack of potential adversaries. Since nuclear facilities or radioactive materials can be attractive targets for terrorists, PPS should be installed and maintained throughout the entire lifecycle of nuclear energy systems. One of key ingredients for effective protection is a reliable assessment procedure of the PPS capability. Due to complexity of possible threat categories and pathways, several pathway analysis programs have been developed to ease analysis or visualization. ASSESS using ASD approach runs fast and adopts a relatively simple modeling process for facility elements. But uncertainty due to assumptions used in modeling might complicate the interpretation of results. On the other hand, 2D pathway program such as TESS can utilize more self-consistent detection probability and delay time since actual pathway on 2D map is available. Also, this pathway visualization helps users understand analysis result more intuitively. But, in general, 2D pathway programs require strong computational power and careful optimization. Another possible difference between two approaches is response force deployment and RFT.

  17. Research on effectiveness assessment programs for physical protection system

    International Nuclear Information System (INIS)

    Seo, Janghoon; Yoo, Hosik; Ham, Taekyu

    2015-01-01

    PPS (Physical Protection System) is an integrated set of procedures, installation and human resources to protect valuable assets from physical attack of potential adversaries. Since nuclear facilities or radioactive materials can be attractive targets for terrorists, PPS should be installed and maintained throughout the entire lifecycle of nuclear energy systems. One of key ingredients for effective protection is a reliable assessment procedure of the PPS capability. Due to complexity of possible threat categories and pathways, several pathway analysis programs have been developed to ease analysis or visualization. ASSESS using ASD approach runs fast and adopts a relatively simple modeling process for facility elements. But uncertainty due to assumptions used in modeling might complicate the interpretation of results. On the other hand, 2D pathway program such as TESS can utilize more self-consistent detection probability and delay time since actual pathway on 2D map is available. Also, this pathway visualization helps users understand analysis result more intuitively. But, in general, 2D pathway programs require strong computational power and careful optimization. Another possible difference between two approaches is response force deployment and RFT

  18. Virtual-reality education and training system for radiation protection

    International Nuclear Information System (INIS)

    Yamamoto, T.; Miyatake, H.; Kawakami, T.

    2002-01-01

    In order to break the mannerism in the education and training method for radiation protection introduction of virtual reality system to the chalkface has been discussed in addition to the usual lecture and video system in the subcommittee established in JRIAS (Japan Radioisotope Association), and the leading model has been installed in Osaka University. It consists of a main server and 3 clients with a software for virtual reality. With this system the trainee could go into the virtual laboratory and handle the radioisotope. In that case he could also experience various accidents such as trivial failure in the experiments, serious hazard, fire, earthquake, etc., which are difficult to suffer in the real laboratory. Hence those who have experienced such a training could come to act rapidly up against any sudden accidents and also the virtual reality system would result decrease in unnecessary radioactive wastes

  19. The association between fall frequency, injury risk and characteristics of falls in older residents of long-term care: do recurrent fallers fall more safely?

    Science.gov (United States)

    van Schooten, Kimberley S; Yang, Yijian; Feldman, Fabio; Leung, Ming; McKay, Heather; Sims-Gould, Joanie; Robinovitch, Stephen N

    2017-10-12

    Although a fall is a necessary prerequisite to a fall-related injury, previous studies suggest that frequent fallers are at lower injury risk for a given fall. We tested the hypotheses that differences in protective responses or the circumstances of falls underlie differences in injury risk with fall frequency. We analyzed video footage of 897 falls experienced by 220 long-term care residents (mean age 82±9 yrs) to identify the cause of imbalance, activity leading to falling, direction of fall initiation, balance recovery and fall protective responses, and occurrence of impact to the head or hip. We further obtained injury information from the facilities' fall registration. We used generalized estimating equation models to examine the association between quartiles of fall frequency, injury risk, and fall characteristics. Residents with the highest fall frequency group (Q4; ≥5.6 falls/year) were less likely to sustain an injury per fall. They were less likely to fall during walking and more likely to fall during stand-to-sit transfers. Residents in the lowest fall frequency group (Q1; falls/year) were more likely to fall during walking, and walking was associated with an increased risk for injury. When compared to less frequent fallers, more frequent fallers had a lower risk for injury per fall. This appeared to be explained by differences in the circumstances of falls, and not by protective responses. Injury prevention strategies in long-term care should target both frequent and infrequent fallers, as the latter are more mobile and apt to sustain injury. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. An equipment protection and safety system for the ASDEX tokamak

    International Nuclear Information System (INIS)

    Gernhardt, J.; Groening, D.; Hohenoecker, H.; Ruhs, N.

    1981-02-01

    Our compromise between safety requirements and costs is a hybrid of relay, solid-state and computer-controlled protection systems used for ASDEX. The toroidal field coils, ohmic heating coils, vertical field coils, divertor coils, radial field coils, stainless-steel vacuum vessel and structure are protected by measuring the water flow (131 channels), temperature (142 channels), mechanical displacements (141 channels), voltage symmetry (28 channels), current symmetry (6 channels), weight of the vessel (8 channels) and the overvoltage. To detect flow, temperature, displacement, voltage, current and weight, we use the following devices: Venturi tubes (self-made), RTD thermoresistors (Pt-100), linear potentiometers (1 kΩ), voltage dividers (self-made), Rogowski coils (self-made) and straing gauges. (orig.) [de

  1. Integral isolation valve systems for loss of coolant accident protection

    Energy Technology Data Exchange (ETDEWEB)

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  2. Reactor protection system design using application specific integrated circuits

    International Nuclear Information System (INIS)

    Battle, R.E.; Bryan, W.L.; Kisner, R.A.; Wilson, T.L. Jr.

    1992-01-01

    Implementing reactor protection systems (RPS) or other engineering safeguard systems with application specific integrated circuits (ASICs) offers significant advantages over conventional analog or software based RPSs. Conventional analog RPSs suffer from setpoints drifts and large numbers of discrete analog electronics, hardware logic, and relays which reduce reliability because of the large number of potential failures of components or interconnections. To resolve problems associated with conventional discrete RPSs and proposed software based RPS systems, a hybrid analog and digital RPS system implemented with custom ASICs is proposed. The actual design of the ASIC RPS resembles a software based RPS but the programmable software portion of each channel is implemented in a fixed digital logic design including any input variable computations. Set point drifts are zero as in proposed software systems, but the verification and validation of the computations is made easier since the computational logic an be exhaustively tested. The functionality is assured fixed because there can be no future changes to the ASIC without redesign and fabrication. Subtle error conditions caused by out of order evaluation or time dependent evaluation of system variables against protection criteria are eliminated by implementing all evaluation computations in parallel for simultaneous results. On- chip redundancy within each RPS channel and continuous self-testing of all channels provided enhanced assurance that a particular channel is available and faults are identified as soon as possible for corrective actions. The use of highly integrated ASICs to implement channel electronics rather than the use of discrete electronics greatly reduces the total number of components and interconnections in the RPS to further increase system reliability. A prototype ASIC RPS channel design and the design environment used for ASIC RPS systems design is discussed

  3. Health protection in Brazil: the National Sanitary Surveillance System.

    Science.gov (United States)

    Seta, Marismary Horsth De; Oliveira, Catia Veronica Dos Santos; Pepe, Vera Lúcia Edais

    2017-10-01

    This essay presents the singular arrangement named Health Surveillance in Brazil and the specificities of its components: public Health Surveillance, Worker's Surveillance, Environmental Surveillance, Sanitary Surveillance, as well as the constitutional determination to carry out the actions of sanitary and epidemiological surveillance and Worker's Surveillance. The two national systems of protection and promote health are also presented - National Public Health Surveillance System and National Sanitary Surveillance System, with an emphasis on the regulatory issues in health made by the latter and some constraints to its action by the Legislative Branch. It reaffirms the Brazilian State's constitutional duty to protect health, and to provide the means for adequate functioning of the two systems, bearing in mind that defense of the public interest in health products and services means confronting oligopolies of transnational economic interests. This paper states the opinion that the financial constraints facing the Brazilian State from time to time cannot be allowed to prevail over the rights of citizenship, independently of the public underfunding of health in Brazil.

  4. Numerical simulation and experimental results of horizontal tube falling film generator working in a NH3-LiNO3 absorption refrigeration system

    International Nuclear Information System (INIS)

    Herrera, J.V.; Garcia-Valladares, O.; Gomez, V.H.; Best, R.

    2010-01-01

    This paper describes the work made at the Centro de Investigacion en Energia in the development of an absorption refrigeration system for cooling and refrigeration applications with a capacity of 10 kW. The single effect unit utilizes ammonia-lithium nitrate as working pair and it is air cooled. The generator is a falling film type with horizontal tubes where the heating oil flows inside the tube bank and the ammonia-lithium nitrate solution flows as a falling film on the tube outside, where it is heated and ammonia vapor is generated. The generator consists of tree columns and four rows per column of horizontal tubes. The system was tested at controlled conditions with heating oil obtained from an electric resistance heating loop. A numerical model of the horizontal falling film generator was developed that divided the system into three different thermal elements: the flow inside the tube, the heat conduction in the tube wall and the falling film solution flow. The mathematical model was tested and validated with experimental data and a study of the influence of the heat transfer coefficient for ammonia-lithium nitrate solution in the numerical model was carried out. A comparison between experimental and numerical data for the heat flux in the system and the temperature profiles in the oil and solution flows shown a good degree of correlation.

  5. Defense against common-mode failures in protection system design

    International Nuclear Information System (INIS)

    Wyman, R.H.; Johnson, G.L.

    1998-01-01

    The introduction of digital instrumentation and control into reactor safety systems creates a heightened concern about common-mode failure. This paper discusses the concern and methods of cope with the concern. Common-mode failures have been a 'fact-of-life' in existing systems. The informal introduction of defense-in-depth and diversity (D-in-D and D) - coupled with the fact that hardware common-mode failures are often distributed in time - has allowed systems to deal with past common-mode failures. However, identical software operating in identical redundant systems presents the potential for simultaneous failure. Consequently, the use of digital systems raises the concern about common-mode failure to a new level. A more methodical approach to mitigating common-mode failure is needed to address these concerns. Purposeful introduction of D-in-D and D has been used as a defense against common-mode failure in reactor protection systems. At least two diverse systems are provided to mitigate any potential initiating event. Additionally, diverse displays and controls are provided to allow the operator to monitor plant status and manually initiate engineered safety features. A special form of common-mode failure analysis called 'defense-in-depth and diversity analysis' has been developed to identify possible common-mode failure vulnerabilities in digital systems. An overview of this analysis technique is provided. (author)

  6. Defense against common-mode failures in protection system design

    International Nuclear Information System (INIS)

    Wyman, R.H.; Johnson, G.L.

    1997-01-01

    The introduction of digital instrumentation and control into reactor safety systems creates a heightened concern about common-mode failure. This paper discusses the concern and methods to cope with the concern. Common-mode failures have been a ''fact-of-life'' in existing systems. The informal introduction of defense-in-depth and diversity (D-in-D ampersand D)-coupled with the fact that hardware common-mode failures are often distributed in time-has allowed systems to deal with past common-mode failures. However, identical software operating in identical redundant systems presents the potential for simultaneous failure. Consequently, the use of digital systems raises the concern about common-mode failure to a new level. A more methodical approach to mitigating common-mode failure is needed to address these concerns. Purposeful introduction of D-in-D ampersand D has been used as a defense against common-mode failure in reactor protection systems. At least two diverse systems are provided to mitigate any potential initiating event. Additionally, diverse displays and controls are provided to allow the operator to monitor plant status and manually initiate engineered safety features. A special form of conimon-mode failure analysis called ''defense-in-depth and diversity analysis'' has been developed to identify possible conimon-mode failure vulnerabilities in digital systems. An overview of this analysis technique is provided

  7. Performance of fall and winter crops in a no tillage system in west Paraná State

    Directory of Open Access Journals (Sweden)

    Leandro Paiola Albrecht

    2017-11-01

    Full Text Available The long-term exploitation of natural resources by agricultural activities has resulted in the need for alternative measures to restore degraded soil. The cultivation of cover crops can generate great benefits for agricultural systems, enabling the exploitation of natural resources, including water, light and nutrients, as well as the recovery of degraded soils. This work aimed to assess the coverage rate, fresh mass and dry mass of cover crops from fall and winter as well as the floristic composition of the weeds. The work was conducted in field conditions in soil classified as eutroferric Red Oxisol in the region of the city of Palotina, Paraná State, Brazil, using a random block experimental design with four replications. The treatments consisted of seven cover cultures: wild radish, linseed, triticale, rye, rapeseed, crambe, oats and fallow. The species with the highest coverage rates and fresh mass and dry mass values were wild radish, rapeseed and crambe. In the floristic and phytosociological data, the species with the highest incidence were Amaranthus retroflexus, Commelina benghalensis L., Brachiaria plantaginea and Gnaphalium spicatum.

  8. NSTX Protection And Interlock Systems For Coil And Powers Supply Systems

    International Nuclear Information System (INIS)

    Zhao, X.; Ramakrishnan, S.; Lawson, J.; Neumeyer, C.; Marsala, R.; Schneider, H.

    2009-01-01

    NSTX at Princeton Plasma Physics Laboratory (PPPL) requires sophisticated plasma positioning control system for stable plasma operation. TF magnetic coils and PF magnetic coils provide electromagnetic fields to position and shape the plasma vertically and horizontally respectively. NSTX utilizes twenty six coil power supplies to establish and initiate electromagnetic fields through the coil system for plasma control. A power protection and interlock system is utilized to detect power system faults and protect the TF coils and PF coils against excessive electromechanical forces, overheating, and over current. Upon detecting any fault condition the power system is restricted, and it is either prevented from initializing or suppressed to de-energize coil power during pulsing. Power fault status is immediately reported to the computer system. This paper describes the design and operation of NSTX's protection and interlocking system and possible future expansion.

  9. Innovative solutions in monitoring systems in flood protection

    Science.gov (United States)

    Sekuła, Klaudia; Połeć, Marzena; Borecka, Aleksandra

    2018-02-01

    The article presents the possibilities of ISMOP - IT System of Levee Monitoring. This system is able to collecting data from the reference and experimental control and measurement network. The experimental levee is build in a 1:1 scale and located in the village of Czernichow, near Cracow. The innovation is the utilization of a series of sensors monitoring the changes in the body of levee. It can be done by comparing the results of numerical simulations with results from installed two groups of sensors: reference sensors and experimental sensors. The reference control and measurement sensors create network based on pore pressure and temperature sensors. Additionally, it contains the fiber-optic technology. The second network include design experimental sensors, constructed for the development of solutions that can be used in existing flood embankments. The results are important to create the comprehensive and inexpensive monitoring system, which could be helpful for state authorities and local governments in flood protection.

  10. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  11. From Tomography to Material Properties of Thermal Protection Systems

    Science.gov (United States)

    Mansour, Nagi N.; Panerai, Francesco; Ferguson, Joseph C.; Borner, Arnaud; Barnhardt, Michael; Wright, Michael

    2017-01-01

    A NASA Ames Research Center (ARC) effort, under the Entry Systems Modeling (ESM) project, aims at developing micro-tomography (micro-CT) experiments and simulations for studying materials used in hypersonic entry systems. X-ray micro-tomography allows for non-destructive 3D imaging of a materials micro-structure at the sub-micron scale, providing fiber-scale representations of porous thermal protection systems (TPS) materials. The technique has also allowed for In-situ experiments that can resolve response phenomena under realistic environmental conditions such as high temperature, mechanical loads, and oxidizing atmospheres. Simulation tools have been developed at the NASA Ames Research Center to determine material properties and material response from the high-fidelity tomographic representations of the porous materials with the goal of informing macroscopic TPS response models and guiding future TPS design.

  12. BIODIVERSITY AND THE PROTECTED AREAS SYSTEM IN ALBANIA

    Directory of Open Access Journals (Sweden)

    Mehmet Metaj

    2009-06-01

    Full Text Available Albania possesses a wide range of ecological systems including coastal zones, estuaries and lagoons, lakes and wetlands, grasslands, middle-low altitude coppice forests, high altitude forests, alpine vegetation and glacial areas. The country possesses about 3,250 species of vascular plants, 165 families and more than 900 genera. Medicinal plants (botanicals and non-timber forest products have a long history of importance in the culture and traditional knowledge of Albania. Proper legislation and especially legal and regulatory framework enforcement for the regulation of this developing industry remains lacking. A Strategy of Biodiversity plan developed in 2000 calls for an increase in the Protected Areas system which currently covers some 6 % of Albania's area to a total area of 435,600 ha, approximately 15 % of the country's territory. Changes in the legal and policy framework as well as institutional structures is required to move forward and provide an environment for biodiversity conservation and a sustainable protected areas system. The various threats to biodiversity and constraints to improvement are outlined as well as recommendations for sustainable use, assessment and regulation.

  13. Dynamic state estimation assisted power system monitoring and protection

    Science.gov (United States)

    Cui, Yinan

    The advent of phasor measurement units (PMUs) has unlocked several novel methods to monitor, control, and protect bulk electric power systems. This thesis introduces the concept of "Dynamic State Estimation" (DSE), aided by PMUs, for wide-area monitoring and protection of power systems. Unlike traditional State Estimation where algebraic variables are estimated from system measurements, DSE refers to a process to estimate the dynamic states associated with synchronous generators. This thesis first establishes the viability of using particle filtering as a technique to perform DSE in power systems. The utility of DSE for protection and wide-area monitoring are then shown as potential novel applications. The work is presented as a collection of several journal and conference papers. In the first paper, we present a particle filtering approach to dynamically estimate the states of a synchronous generator in a multi-machine setting considering the excitation and prime mover control systems. The second paper proposes an improved out-of-step detection method for generators by means of angular difference. The generator's rotor angle is estimated with a particle filter-based dynamic state estimator and the angular separation is then calculated by combining the raw local phasor measurements with this estimate. The third paper introduces a particle filter-based dual estimation method for tracking the dynamic states of a synchronous generator. It considers the situation where the field voltage measurements are not readily available. The particle filter is modified to treat the field voltage as an unknown input which is sequentially estimated along with the other dynamic states. The fourth paper proposes a novel framework for event detection based on energy functions. The key idea is that any event in the system will leave a signature in WAMS data-sets. It is shown that signatures for four broad classes of disturbance events are buried in the components that constitute the

  14. The millennium problem and physical protection systems in UK

    International Nuclear Information System (INIS)

    Groves, J.

    1999-01-01

    In the United Kingdom the Competent Authority is Nuclear Industries Directorate of the UK Government's department of Trade and Industry. It is charged with ensuring that the security regimes at all civil nuclear sites in the country conform with the rues laid down by Government. This task is achieved through giving advice, issuing and interpreting policy, performing trustworthiness checks and conducting security assessments of all aspects of security. This presentation is not concerned with safety or safeguards systems but purely with those concerned with physical protection

  15. Field repair of coated columbium Thermal Protection System (TPS)

    Science.gov (United States)

    Culp, J. D.

    1972-01-01

    The requirements for field repair of coated columbian panels were studied, and the probable cause of damage were identified. The following types of repair methods were developed, and are ready for use on an operational system: replacement of fused slurrey silicide coating by a short processing cycle using a focused radiant spot heater; repair of the coating by a glassy matrix ceramic composition which is painted or sprayed over the defective area; and repair of the protective coating by plasma spraying molybdenum disilicide over the damaged area employing portable equipment.

  16. Creditor Protection and Banking System Development in India

    OpenAIRE

    Simon Deakin; Panicos Demetriades; Gregory James

    2008-01-01

    We use a new legal dataset tracking changes in creditor protection law over several decades to study the impact of legal reforms on banking system development in India. Cointegration analysis is used to show that the strengthening of creditor rights in relation to the enforcement of security interests in the 1990s and 2000s led to an increase in bank credit. We show that the change in the law was not endogenous to trends in stock market development and GDP per capita, and that the direction o...

  17. Identification of protective antigens for vaccination against systemic salmonellosis

    Directory of Open Access Journals (Sweden)

    Dirk eBumann

    2014-08-01

    Full Text Available There is an urgent medical need for improved vaccines with broad serovar coverage and high efficacy against systemic salmonellosis. Subunit vaccines offer excellent safety profiles but require identification of protective antigens, which remains a challenging task. Here, I review crucial properties of Salmonella antigens that might help to narrow down the number of potential candidates from more than 4000 proteins encoded in Salmonella genomes, to a more manageable number of 50-200 most promising antigens. I also discuss complementary approaches for antigen identification and potential limitations of current pre-clinical vaccine testing.

  18. Equipment design for reliability testing of protection system

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Tjahjono, H.; Santosa, A. Z.; Tjahjani, S.DT.; Ismu, P.H; Haryanto, D.; Mulyanto, D.; Kusmono, S

    1999-01-01

    The equipment for reliability testing of cable of protection system has been designed as a a furnace with the electric heater have a 4 kW power, and need time 10 minute to reach the designed maximum temperature 3000C. The dimension of furnace is 800 mm diameter and 2000 mm length is isolated use rockwool isolator and coated by aluminium. For the designed maximum temperature the surface temperature is 78 0c. Assemble of specimens is arranged horizontally in the furnace. The failure criteria will be defined based on the behaviour of the load circuit in each line of cable specimens

  19. District heating systems between competition protection and climate protection; Die Fernwaermenetze zwischen Wettbewerbs- und Klimaschutz

    Energy Technology Data Exchange (ETDEWEB)

    Koerber, Torsten [Goettingen Univ. (Germany). Lehrstuhl fuer Buergerliches Recht, Kartellrecht, Versicherungs-, Gesellschafts- und Regulierungsrecht

    2012-10-15

    In principle, district heating systems come in the application area of paragraph 19 sect. 4 no. 4 GWB (law against competitive restrictions). However, this regulation has to be interpreted with respect to the legislation of the Court of Justice of the European Union (Luxemburg) to 'essential facilities'. According to this, the claim for antitrust access can be affirmed only in exceptional circumstances. Within the application of this regulation, property rights, competition protection, investment competition, innovation competition as well as energy political evaluations of the energy law under special consideration of ecologic and climate political targets are considered. This has to occur within the testing of the reasonability with respect to paragraph 19 sect. 4 no. 2 GWB. The particularities of the district heating.

  20. How Do Community-Dwelling Persons with Alzheimer Disease Fall? Falls in the FINALEX Study.

    Science.gov (United States)

    Perttila, Niko M; Öhman, Hannareeta; Strandberg, Timo E; Kautiainen, Hannu; Raivio, Minna; Laakkonen, Marja-Liisa; Savikko, Niina; Tilvis, Reijo S; Pitkala, Kaisu H

    2017-01-01

    People with dementia are at high risk for falls. However, little is known of the features causing falls in Alzheimer disease (AD). Our aim was to investigate how participants with AD fall. In the FINALEX (Finnish Alzheimer Disease Exercise Trial) study, participants' ( n = 194) falls were followed up for 1 year by diaries kept by their spouses. The most common reason for falls ( n = 355) was stumbling ( n = 61). Of the falls, 123 led to injuries, 50 to emergency department visits, and 13 to fractures. The participants without falls ( n = 103) were younger and had milder dementia than those with 1 ( n = 34) or ≥2 falls ( n = 57). Participants with a Mini Mental State Examination score of around 10 points were most prone to fall. In adjusted regression models, good nutritional status, good physical functioning, and use of antihypertensive medication (incident rate ratio [IRR] 0.68, 95% confidence interval [CI] 0.54-0.85) protected against falls, whereas fall history (IRR 2.71, 95% CI 2.13-3.44), osteoarthritis, diabetes mellitus, chronic obstructive pulmonary disease, higher number of drugs, drugs with anticholinergic properties, psychotropics, and opioids (IRR 4.27, 95% CI 2.92-6.24) were risk factors for falls. Our study provides a detailed account on how and why people with AD fall, suggesting several risk and protective factors.

  1. How Do Community-Dwelling Persons with Alzheimer Disease Fall Falls in the FINALEX Study

    Directory of Open Access Journals (Sweden)

    Niko M. Perttila

    2017-06-01

    Full Text Available Background: People with dementia are at high risk for falls. However, little is known of the features causing falls in Alzheimer disease (AD. Our aim was to investigate how participants with AD fall. Methods: In the FINALEX (Finnish Alzheimer Disease Exercise Trial study, participants’ (n = 194 falls were followed up for 1 year by diaries kept by their spouses. Results: The most common reason for falls (n = 355 was stumbling (n = 61. Of the falls, 123 led to injuries, 50 to emergency department visits, and 13 to fractures. The participants without falls (n = 103 were younger and had milder dementia than those with 1 (n = 34 or ≥2 falls (n = 57. Participants with a Mini Mental State Examination score of around 10 points were most prone to fall. In adjusted regression models, good nutritional status, good physical functioning, and use of antihypertensive medication (incident rate ratio [IRR] 0.68, 95% confidence interval [CI] 0.54–0.85 protected against falls, whereas fall history (IRR 2.71, 95% CI 2.13–3.44, osteoarthritis, diabetes mellitus, chronic obstructive pulmonary disease, higher number of drugs, drugs with anticholinergic properties, psychotropics, and opioids (IRR 4.27, 95% CI 2.92–6.24 were risk factors for falls. Conclusions: Our study provides a detailed account on how and why people with AD fall, suggesting several risk and protective factors.

  2. A piece of paper falling faster than free fall

    International Nuclear Information System (INIS)

    Vera, F; Rivera, R

    2011-01-01

    We report a simple experiment that clearly demonstrates a common error in the explanation of the classic experiment where a small piece of paper is put over a book and the system is let fall. This classic demonstration is used in introductory physics courses to show that after eliminating the friction force with the air, the piece of paper falls with acceleration g. To test if the paper falls behind the book in a nearly free fall motion or if it is dragged by the book, we designed a version of this experiment that includes a ball and a piece of paper over a book that is forced to fall using elastic cords. We recorded a video of our experiment using a high-speed video camera at 300 frames per second that shows that the book and the paper fall faster than the ball, which falls well behind the book with an acceleration approximately equal to g. Our experiment shows that the piece of paper is dragged behind the book and therefore the paper and book demonstration should not be used to show that all objects fall with acceleration g independently of their mass.

  3. The future of substation automation (protection, control, system)

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Hossenlopp, L. [Areva T and D Automation Inc., Paris (France); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    This paper described a high-level plan for implementing wide-area control in an energy management system (EMS) designed to improve power system grid security and protect the electrical interconnection from a widespread collapse. The appropriate action in some cases would be islanding and blacking out a portion of the grid in order to prevent widespread collapse. The use of new automation solutions can address costly shortcomings in capacity, reliability, power quality and security. International organizations such as the Institute of Electrical and Electronics Engineers (IEEE), International Electrotechnical Commission (IEC) and the Conseil International des Grands Reseaux Electriques (CIGRE) launched several working groups to analyze the context of major blackouts and develop concepts for the use of new technologies and coordinated investment strategies to modernize the power system infrastructure. The main benefits of such smart grid systems would be: no wide-area blackouts, far fewer localized disruptions, and faster recovery when disruptions do occur; greater security from self-healing technologies and better real-time monitoring and response; high-quality power needed for sensitive electronics and computer applications; and new options for consumers to manage their electricity use and costs. The authors noted that in order to gain the full advantages of the new IEC 61850 standard there is a need to change project execution processes and prioritize various changes. This paper demonstrated the importance of system design and outlined some system engineering and interoperability tests aspects. 17 figs.

  4. Flight envelope protection system for unmanned aerial vehicles

    KAUST Repository

    Claudel, Christian G.

    2016-04-28

    Systems and methods to protect the flight envelope in both manual flight and flight by a commercial autopilot are provided. A system can comprise: an inertial measurement unit (IMU); a computing device in data communication with the IMU; an application executable by the computing device comprising: logic that estimates an angle of attack; a slip angle; and a speed of an unmanned aerial vehicle (UAV) based at least in part on data received from the UAV. A method can comprise estimating, via a computing device, flight data of a UAV based at least in part on data received from an IMU; comparing the estimated flight data with measured flight data; and triggering an error indication in response to a determination that the measured flight data exceeds a predefined deviation of the estimated flight data. The estimated speed can comprise an estimated airspeed, vertical speed and/or ground velocity.

  5. Preliminary design of the thermal protection system for solar probe

    Science.gov (United States)

    Dirling, R. B., Jr.; Loomis, W. C.; Heightland, C. N.

    1982-01-01

    A preliminary design of the thermal protection system for the NASA Solar Probe spacecraft is presented. As presently conceived, the spacecraft will be launched by the Space Shuttle on a Jovian swing-by trajectory and at perihelion approach to three solar radii of the surface of the Earth's sun. The system design satisfies maximum envelope, structural integrity, equipotential, and mass loss/contamination requirements by employing lightweight carbon-carbon emissive shields. The primary shield is a thin shell, 15.5-deg half-angle cone which absorbs direct solar flux at up to 10-deg off-nadir spacecraft pointing angles. Secondary shields of sandwich construction and low thickness-direction thermal conductivity are used to reduce the primary shield infrared radiation to the spacecraft payload.

  6. Intercropping System for Protection the Potato Plant from Insect Infestation

    Directory of Open Access Journals (Sweden)

    Aziza Sharaby

    2015-06-01

    Full Text Available The use of intercropping system provides an option for insect control for organic farmers that are limited in their chemical use. Additionally, intercropping systems can be attractive to conventional growers as a cost-effective insect control solution. A study was carried out for two seasons 2011-2012 and 2012-2013 to evaluate the effect of intercropping of potato (Solanum tuberosum L. with onion (Allium cepa L. on whitefly (Bemicia tabasi Gennadius and aphids’ Myzus persicae Sulz. and Aphis gossypii Glover infestation in potato fields. Results indicated that intercropping significantly reduced potato plant infestation with whitefly by 42.7, 51.3% while it was 62.69% reduction with aphids during the two successive winter seasons than when potato plants were cultivated alone. Therefore, intercropping could be recommended as a protection method of reducing pest population in the fields.

  7. Evaluation methodology for fixed-site physical protection systems

    International Nuclear Information System (INIS)

    Bennett, H.A.; Olascoaga, M.T.

    1980-01-01

    A system performance evaluation methodology has been developed to aid the Nuclear Regulatory Commission (NRC) in the implementation of new regulations designed to upgrade the physical protection of nuclear fuel cycle facilities. The evaluation methodology, called Safeguards Upgrade Rule Evaluation (SURE), provides a means of explicitly incorporating measures for highly important and often difficult to quantify performance factors, e.g., installation, maintenance, training and proficiency levels, compatibility of components in subsystems, etc. This is achieved by aggregating responses to component and system questionaires through successive levels of a functional hierarchy developed for each primary performance capability specified in the regulations, 10 CFR 73.45. An overall measure of performance for each capability is the result of this aggregation process. This paper provides a descripton of SURE

  8. 75 FR 47464 - Exemption to Prohibition on Circumvention of Copyright Protection Systems for Access Control...

    Science.gov (United States)

    2010-08-06

    ... Prohibition on Circumvention of Copyright Protection Systems for Access Control Technologies AGENCY: Copyright... nonsubstantial correction to its regulation announcing the prohibition against circumvention of technological... the final rule governing exemption to prohibition on circumvention of copyright protection systems for...

  9. 75 FR 16676 - Airworthiness Standards; Electrical and Electronic System Lightning Protection

    Science.gov (United States)

    2010-04-02

    ... appliances and for the design, material, construction, quality of work, and performance of aircraft, aircraft..., regulations applicable to lightning protection for aircraft design, construction, and fuel systems were... lightning protection regulations for electrical and electronic systems installed on aircraft certificated...

  10. Wecpos - Wave Energy Coastal Protection Oscillating System: A Numerical Assessment

    Science.gov (United States)

    Dentale, Fabio; Pugliese Carratelli, Eugenio; Rzzo, Gianfranco; Arsie, Ivan; Davide Russo, Salvatore

    2010-05-01

    In recent years, the interest in developing new technologies to produce energy with low environmental impact by using renewable sources has grown exponentially all over the world. In this context, the experiences made to derive electricity from the sea (currents, waves, etc.) are of particular interest. At the moment, due to the many existing experiments completed or still in progress, it is quite impossible explain what has been obtained but it is worth mentioning the EMEC, which summarizes the major projects in the world. Another important environmental aspect, also related to the maritime field, is the coastal protection from the sea waves. Even in this field, since many years, the structural and non-structural solutions which can counteract this phenomenon are analyzed, in order to cause the least possible damage to the environment. The studies in development by the researchers of the University of Salerno are based on these two aspect previously presented. Considering the technologies currently available, a submerged system has been designed, WECPOS (Wave Energy Coastal Protection Oscillating System), to be located on relatively shallow depths, to can be used simultaneously for both electricity generation and for the coastal protection using the oscillating motion of the water particles. The single element constituting the system is realized by a fixed base and three movable panels that can fluctuate in a fixed angle. The waves interact with the panels generating an alternative motion which can be exploited to produce electricity. At the same time, the constraint movement imposed for the rotation of the panels is a barrier to the wave propagation phenomena, triggering the breaking in the downstream part of the device. So the wave energy will be dissipated obtaining a positive effect for the coastal protection. Currently, the efficiency and effectiveness of the system (WECPOS single module) has been studied by using numerical models. Using the FLOW-3D

  11. Reported Systems Changes and Sustainability Perceptions of Three State Departments of Health Implementing Multi-Faceted Evidence-Based Fall Prevention Efforts

    Directory of Open Access Journals (Sweden)

    Matthew Lee Smith

    2017-06-01

    Full Text Available Although the concepts of systems change and sustainability are not new, little is known about the factors associated with systems change sustaining multi-state, multi-level fall prevention efforts. This exploratory study focuses on three State Departments of Health (DOH that were awarded 5-year funding from the Centers for Disease Control and Prevention to simultaneously implement four separate yet related evidence-based fall prevention initiatives at the clinical, community, and policy level. The purpose of this study was to examine changes in partnerships and collaborative activities that occurred to accomplish project goals (examining changes in the context of “before funding” and “after funding was received”. Additionally, this study explored changes in State DOH perceptions about action related to sustainability indicators in the context of “during funding” and “after funding ends.” Findings from this study document the partnership and activity changes necessary to achieve defined fall prevention goals after funding is received, and that the importance of sustainability indicator documentation is seen as relevant during funding, but less so after the funding ends. Findings from this study have practice and research implications that can inform future funded efforts in terms of sector and stakeholder engagement necessary for initiating, implementing, and sustaining community- and clinical-based fall prevention interventions.

  12. Reported Systems Changes and Sustainability Perceptions of Three State Departments of Health Implementing Multi-Faceted Evidence-Based Fall Prevention Efforts

    Science.gov (United States)

    Smith, Matthew Lee; Schneider, Ellen C.; Byers, Imani N.; Shubert, Tiffany E.; Wilson, Ashley D.; Towne, Samuel D.; Ory, Marcia G.

    2017-01-01

    Although the concepts of systems change and sustainability are not new, little is known about the factors associated with systems change sustaining multi-state, multi-level fall prevention efforts. This exploratory study focuses on three State Departments of Health (DOH) that were awarded 5-year funding from the Centers for Disease Control and Prevention to simultaneously implement four separate yet related evidence-based fall prevention initiatives at the clinical, community, and policy level. The purpose of this study was to examine changes in partnerships and collaborative activities that occurred to accomplish project goals (examining changes in the context of “before funding” and “after funding was received”). Additionally, this study explored changes in State DOH perceptions about action related to sustainability indicators in the context of “during funding” and “after funding ends.” Findings from this study document the partnership and activity changes necessary to achieve defined fall prevention goals after funding is received, and that the importance of sustainability indicator documentation is seen as relevant during funding, but less so after the funding ends. Findings from this study have practice and research implications that can inform future funded efforts in terms of sector and stakeholder engagement necessary for initiating, implementing, and sustaining community- and clinical-based fall prevention interventions. PMID:28642861

  13. A New Protection System for Islanding Detection in LV Distribution Systems

    Directory of Open Access Journals (Sweden)

    Anna Rita Di Fazio

    2015-04-01

    Full Text Available The growth of penetration of Distributed Generators (DGs is increasing the risk of unwanted islanded operation in Low Voltage (LV distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match between generation and load. In this paper, a new protection system for islanding detection in LV distribution systems is proposed. The classical voltage and frequency relays in the DG interface protections are enriched with an innovative Smart Islanding Detector, which adopts a new passive islanding detection method. The aim is to keep the advantages of the classical relays while overcoming the problem of their limited sensitivity in detecting balanced islands. In the paper, to define the requirements of the anti-islanding protection system, the events causing the islanded operation of the LV distribution systems are firstly identified and classified. Then, referring to proposed protection system, its architecture and operation are described and, eventually, its performance is analyzed and validated by experimental laboratory tests, carried out with a hardware-in-the-loop technique.

  14. Objective Metric Based Assessments for Efficient Evaluation of Auditory Situation Awareness Characteristics of Tactical Communications and Protective Systems (TCAPS) and Augmented Hearing Protective Devices (HPDs)

    Science.gov (United States)

    2015-11-30

    Assessments for Efficient Evaluation of Auditory Situation Awareness Characteristics of Tactical Communications and Protective Systems (TCAPS) and Augmented... auditory situation awareness (ASA) that objectively quantified the ASA performance afforded by various Tactical Communications and Protection Systems...HPD, tactical communications and protection systems, hearing protection devices, auditory situation awareness, ASA, DRILCOM U U U UU 95 Michael E

  15. 77 FR 23464 - Updates to List of National System of Marine Protected Areas (MPAs)

    Science.gov (United States)

    2012-04-19

    ... Protected Areas (MPAs) AGENCY: NOAA, Department of Commerce (DOC). ACTION: Notice of updates to the List of National System of Marine Protected Areas (MPAs) and response to comments on nominations of existing MPAs to the national system. SUMMARY: The National System of Marine Protected Areas (MPAs) provides a...

  16. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  17. 'H-Bahn' - Dortmund demonstration system. Automatic vehicle protection system

    Energy Technology Data Exchange (ETDEWEB)

    Rosenkranz

    1984-01-01

    The automatic vehicle protection system of the H-Bahn at the Universtiy of Dortmund is responsible for fail-safe operating of the automatic vehicles. Its functions are protection of vehicle operation and protection of passengers boarding and leaving the vehicles. These functions are managed decentrally by two fail-safe operating controllers. Besides the well-known relay-techniques of railway-fail-safe systems, electronics are applied which are based on safe operating URTL-microcontrollers. These are controlled by software stored in EPROMs. A connection link using glass-fibres serves for safe data-exchange between the two fail-safe operating controllers. The experts' favourable reports on 'train protection and safety during passenger processing' were completed in March 84; thus, transportation of passengers could start in April 84.

  18. Protected areas as social-ecological systems: perspectives from resilience and social-ecological systems theory

    Science.gov (United States)

    Cumming, Graeme S.; Allen, Craig R.

    2017-01-01

    Conservation biology and applied ecology increasingly recognize that natural resource management is both an outcome and a driver of social, economic, and ecological dynamics. Protected areas offer a fundamental approach to conserving ecosystems, but they are also social-ecological systems whose ecological management and sustainability are heavily influenced by people. This editorial, and the papers in the invited feature that it introduces, discuss three emerging themes in social-ecological systems approaches to understanding protected areas: (1) the resilience and sustainability of protected areas, including analyses of their internal dynamics, their effectiveness, and the resilience of the landscapes within which they occur; (2) the relevance of spatial context and scale for protected areas, including such factors as geographic connectivity, context, exchanges between protected areas and their surrounding landscapes, and scale dependency in the provision of ecosystem services; and (3) efforts to reframe what protected areas are and how they both define and are defined by the relationships of people and nature. These emerging themes have the potential to transform management and policy approaches for protected areas and have important implications for conservation, in both theory and practice.

  19. Protected areas as social-ecological systems: perspectives from resilience and social-ecological systems theory.

    Science.gov (United States)

    Cumming, Graeme S; Allen, Craig R

    2017-09-01

    Conservation biology and applied ecology increasingly recognize that natural resource management is both an outcome and a driver of social, economic, and ecological dynamics. Protected areas offer a fundamental approach to conserving ecosystems, but they are also social-ecological systems whose ecological management and sustainability are heavily influenced by people. This editorial, and the papers in the invited feature that it introduces, discuss three emerging themes in social-ecological systems approaches to understanding protected areas: (1) the resilience and sustainability of protected areas, including analyses of their internal dynamics, their effectiveness, and the resilience of the landscapes within which they occur; (2) the relevance of spatial context and scale for protected areas, including such factors as geographic connectivity, context, exchanges between protected areas and their surrounding landscapes, and scale dependency in the provision of ecosystem services; and (3) efforts to reframe what protected areas are and how they both define and are defined by the relationships of people and nature. These emerging themes have the potential to transform management and policy approaches for protected areas and have important implications for conservation, in both theory and practice. © 2017 by the Ecological Society of America.

  20. System 80+{trademark} standard design incorporates radiation protection lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    Crom, T.D.; Naugle, C.L. [Duke Engineering & Services, Inc., Charlotte, NC (United States); Turk, R.S. [ABB Combustion Engineering Nuclear Power, Windsor, CT (United States)

    1995-03-01

    Many lessons have been learned from the current generation of nuclear plants in the area of radiation protection. The following paper will outline how the lessons learned have been incorporated into the design and operational philosophy of the System 80+{trademark} Standard Design currently under development by ABB Combustion Engineering (ABB-CE) with support from Duke Engineering and Services, Inc. and Stone and Webster Engineering Corporation in the Balance-of-Plant design. The System 80+{trademark} Standard Design is a complete nuclear power plant for national and international markets, designed in direct response to utility needs for the 1990`s, and scheduled for Nuclear Regulatory Commission (NRC) Design Certification under the new standardization rule (10 CFR Part 52). System 80+{trademark} is a natural extension of System 80{sup R} technology, an evolutionary change based on proven Nuclear Steam Supply System (NSSS) in operation at Palo Verde in Arizona and under construction at Yonggwang in the Republic of Korea. The System 80+{trademark} Containment and much of the Balance of Plant design is based upon Duke Power Company`s Cherokee Plant, which was partially constructed in the late 1970`s, but, was later canceled (due to rapid declined in electrical load growth). The System 80+{trademark} Standard Design meets the requirements given in the Electric Power Research Institute (EPRI) Advanced Light Water Reactor (ALWR) Requirements Document. One of these requirements is to limit the occupational exposure to 100 person-rem/yr. This paper illustrates how this goal can be achieved through the incorporation of lessons learned, innovative design, and the implementation of a common sense approach to operation and maintenances practices.

  1. Calculating the Lightning Protection System Downconductors' Grounding Resistance at Launch Complex 39B, Kennedy Space Center

    Science.gov (United States)

    Mata, Carlos T.; Mata, Angel G.

    2012-01-01

    A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. Nine downconductors (each about 250 meters long) are connected to the catenary wire system. Each downconductor is connected to a 7.62-meter-radius circular counterpoise conductor with six equally spaced, 6-meter-long vertical grounding rods. Grounding requirements at LC39B call for all underground and aboveground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bonded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple directions around LC39B. The complexity of this grounding system makes the fall-of-potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the grounding impedance of the downconductors, an Earth Ground Clamp (EGC) (a stakeless device for measuring grounding impedance) and an Alternative Transient Program (ATP) model of the LPS are used. The EGC is used to measure the loop impedance plus the grounding impedance of each downconductor, and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding resistance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the EGC measurements.

  2. Programming Guidelines for FBD Programs in Reactor Protection System Software

    International Nuclear Information System (INIS)

    Jung, Se Jin; Lee, Dong Ah; Kim, Eui Sub; Yoo, Jun Beom; Lee, Jang Su

    2014-01-01

    Properties of programming languages, such as reliability, traceability, etc., play important roles in software development to improve safety. Several researches are proposed guidelines about programming to increase the dependability of software which is developed for safety critical systems. Misra-c is a widely accepted programming guidelines for the C language especially in the sector of vehicle industry. NUREG/CR-6463 helps engineers in nuclear industry develop software in nuclear power plant systems more dependably. FBD (Function Block Diagram), which is one of programming languages defined in IEC 61131-3 standard, is often used for software development of PLC (programmable logic controllers) in nuclear power plants. Software development for critical systems using FBD needs strict guidelines, because FBD is a general language and has easily mistakable elements. There are researches about guidelines for IEC 61131-3 programming languages. They, however, do not specify details about how to use languages. This paper proposes new guidelines for the FBD based on NUREG/CR-6463. The paper introduces a CASE (Computer-Aided Software Engineering) tool to check FBD programs with the new guidelines and shows availability with a case study using a FBD program in a reactor protection system. The paper is organized as follows

  3. Trivial risks and the new radiation protection system

    International Nuclear Information System (INIS)

    Wikman, Per

    2004-01-01

    The International Commission on Radiological Protection proposes that doses below a certain level should be excluded from the system of protection, without regard to the number of people exposed. As the Commission assumes that there is a risk of harm even from very low doses, the proposal also disregards these very low risks. The arguments for this proposal are examined here. It is argued that the fact that risks are small compared to natural sources cannot be used as justification for accepting them. The principle 'if the risk of harm to the health of the most exposed individual is trivial, then the total risk is trivial-irrespective of how many people are exposed' is analysed. It is found to equivocate on the meaning of the word trivial and to ignore the total risk. It is also argued that the new proposal is not justified by a change from a utilitarian ethic to an ethic based on individual rights. Finally, it is suggested that small doses should only be disregarded if the expected value of harm is small, and the exclusion level should thus depend on the number of people exposed

  4. Epidemiology of Falls in Older Age

    Science.gov (United States)

    Peel, Nancye May

    2011-01-01

    Worldwide, falls among older people are a public health concern because of their frequency and adverse consequences in terms of morbidity, mortality, and quality of life, as well as their impact on health system services and costs. This epidemiological review outlines the public health burden of falls and fall-related injuries and the impact of…

  5. Evaluating physical protection systems of licensed nuclear facilities using systems engineered inspection guidance

    International Nuclear Information System (INIS)

    Bradley, R.T.; Olson, A.W.; Rogue, F.; Scala, S.; Richard, E.W.

    1980-01-01

    The Lawrence Livermore National Laboratory (LLNL) and the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) have applied a systems engineering approach to provide the NRC Office of Inspection and Enforcement (IE) with improved methods and guidance for evaluating the physical protection systems of licensed nuclear facilities

  6. Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

    CERN Document Server

    Pfeffer, H.; Wolff, D.

    2016-01-01

    Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

  7. A New GPS-based Digital Protection System for Smart Grids in Loop Structure

    Directory of Open Access Journals (Sweden)

    X. Liu

    2014-12-01

    Full Text Available This paper presents a new digital protection system to solve the protection challenges in future smart grids, i.e., fast protection and fault isolation in a loop-structured system with limited magnitude of fault current. The new system combines two protection algorithms, i.e., a differential protection as the primary algorithm and an overcurrent protection as the backup one. The new system uses real-time Ethernet and digital data acquisition techniques to overcome the restriction on data transmission over large grids. The current measurements at different locations are time-synchronized by GPS clocks, and then transmitted to a central computer via the Ethernet. As opposed to digital relays which often contain PMU functionality nowadays, this approach uses time stamps on the instantaneous current values. We build a prototype of the new system on a test-bed. The results from simulations and experiments have demonstrated that the protection system achieves fast and accurate protection.

  8. A detailed study of patent system for protection of inventions.

    Science.gov (United States)

    Tulasi, G Krishna; Rao, B Subba

    2008-09-01

    Creations of brain are called intellect. Since these creations have good commercial value, are called as property. Inventions are intellectual property and can be protected by patents provided the invention is novel, non-obvious, useful and enabled. To have fare trade among member countries, World Trade Organisation proposed TRIPS agreement. India had taken necessary initiation by signing the World Trade Organisation agreement and transformed to global needs. The aim of this article is to enlighten pharmaceutical professionals especially in the field of research and development about planning inventions by thorough review of prior-art, which saves time and money. A thorough understanding is made possible by providing details of origin; present governing bodies, their role along with the Act that is safeguarding the patent system.

  9. Verification station for Sandia/Rockwell Plutonium Protection system

    International Nuclear Information System (INIS)

    Nicholson, N.; Hastings, R.D.; Henry, C.N.; Millegan, D.R.

    1979-04-01

    A verification station has been designed to confirm the presence of plutonium within a container module. These container modules [about 13 cm (5 in.) in diameter and 23 cm (9 in.) high] hold sealed food-pack cans containing either plutonium oxide or metal and were designed by Sandia Laboratories to provide security and continuous surveillance and safety. After the plutonium is placed in the container module, it is closed with a solder seal. The verification station discussed here is used to confirm the presence of plutonium in the container module before it is placed in a carousel-type storage array inside the plutonium storage vault. This measurement represents the only technique that uses nuclear detectors in the plutonium protection system

  10. Tabletop exercise as a tool of evaluating physical protection system

    International Nuclear Information System (INIS)

    Matsuzawa, Reina

    2014-01-01

    Evaluation of designed and implemented physical protection system (PPS) is essential for ensuring the effectiveness of PPS. In Japan, nuclear facility operators, which are required to assess performance of PPS, have conducted performance test of PPS element and periodical trainings as well as annual PPS exercise with relevant agencies. In addition to these practical or field efforts, non-field tool for evaluating PPS effectiveness such as tabletop exercise (TTX) can be utilized as it is applied in the USA and other countries. This paper discusses the potential advantage of TTX as an evaluation tool of PPS effectiveness, looking at the characterizations of TTX in comparison to field evaluations, and potential cases where operator would get benefit from TTX especially. (author)

  11. A Religious Worldview: Protecting One's Meaning System Through Religious Prejudice.

    Science.gov (United States)

    Goplen, Joanna; Plant, E Ashby

    2015-11-01

    For some people, religion strongly influences their worldviews. We propose that religious outgroups threaten the foundational beliefs of people with strong religious worldviews (RWVs) by endorsing alternative belief systems and that this threat contributes to religious prejudice. To examine these ideas, we developed a measure of RWV strength and assessed the role of RWV threat in religious prejudice. Across five studies, strength of RWV was related to religious prejudice, including derogation and denial of alternative religious viewpoints, as well as support for suppressing, avoiding, and even aggressing against religious outgroups. These responses were strongest toward religious outgroups whose worldviews were the most different, and therefore most threatening. Mediational analyses revealed that strong RWV people expressed heightened prejudice because of the worldview threat posed by religious outgroup members. These findings indicate that the avoidance and subjugation of religious outgroups can serve as a worldview protection strategy for some people. © 2015 by the Society for Personality and Social Psychology, Inc.

  12. Insights from a reliability review of digital plant protection system

    International Nuclear Information System (INIS)

    Kim, I.S.; Hwang, S.W.; Kim, B.S.; Jeong, C.H.; Oh, S.H.

    2001-01-01

    The full text follows: As part of the design efforts for Ulchin nuclear power plant units 5 and 6 of Korea, a reliability analysis of digital plant protection system (DPPS) was performed by ABB-CE. An independent review of the DPPS reliability analysis was undertaken by Hanyang University to assist Korea Institute of Nuclear Safety (KINS), the nuclear regulatory body of Korea, in evaluating the design acceptability of the digital system. The DPPS is designed to encompass both reactor trip function and ESFAS (engineered safety feature actuation system) initiation function. The major methods used by the ABB-CE to assess the Ulchin 5-6 DPPS reliability are failure mode and effect analysis (FMEA) and fault tree analysis. Hence, our independent review was conducted focusing on: -) the establishment of review criteria based on various sources, such as the standard review plan of KINS, 10CFR50 Appendix A, IEEE standards 279, 577, and 603; -) the suitability of the FMEA and fault tree analysis for the Ulchin 5-6 DPPS, including the specific methods used (e.g., for human reliability analysis and common-cause failure analysis), the assumptions made (e.g., with respect to test frequency and watchdog timer coverage), and the data employed (e.g., CCF parameter, human error probability, and processor failure rate); and -) the design acceptability of the DPPS especially as compared to the analog plant protection system from a reliability and safety perspective. The paper shall also discuss key issues requiring further in-depth investigation, such as reliability of programmable logic controllers (PLCs), coverage factor of watchdog timers, and susceptibility of redundant digital units to common cause failure. Sensitivity analyses were carried out to investigate the impact of several parameters of special interest, like the coverage factor of watchdog timer and human error probability (e.g. an operator error to manually trip the reactor, or to mis-calibrate the trip parameters) on

  13. Computational fluid dynamic modeling of protective clothing systems

    NARCIS (Netherlands)

    Gibson, P.; Barry, J.; Hill, R.; Brasser, P.; Sobera, M.; Kleijn, C.

    2006-01-01

    Protective clothing provides laboratory and hazardous materials workers, fire fighters, military personnel, and others with the means to control their exposure to chemicals, biological materials, and heat sources. Depending on the specific application, the textile materials used in protective

  14. Skin protection against dicarbonyl stress by the glyoxalase system.

    Science.gov (United States)

    Sabrina, Radjei; Emmanuelle, Leblanc; Sylvianne, Schnebert; Carine, Nizard; Bertrand, Friguet; Isabelle, Petropoulos

    2014-10-01

    Skin ageing is the result of intrinsic and photo-ageing, due to UV exposure, that both share important molecular features including alterations of proteins. Indeed, proteins can be modified by many molecular processes such as glycation. Glycation occurs when glucose or its derivates the dicarbonyl compounds glyoxal (GO) and methylglyoxal (MG) react with amines of proteins leading to the formation of advanced glycation endproducts (AGE). The aim of this work is to better understand the role of glyoxalases in the detoxification of glyoxal and methylglyoxal and in the protection of keratinocyte's proteins during skin ageing. In order to understand how glyoxalases are regulated in human skin during intrinsic and photo-ageing, skin sections from 10 young and 10 old donors from photoexposed and photoprotected zones were analysed by immunohistochemistry. The glyoxalase system, glyoxalase 1 (Glo1) and glyoxalase 2 (Glo2), and AGE were localized and analysed in the skin samples. To understand the role of glyoxalases in response to dicarbonyl stress in keratinocytes, HaCaT cells were subjected to a 24h GO or MG stress and glyoxalases expression and activities were determined. Finally, proteomic studies were performed on cellular clones overexpressing Glo2 or inhibiting for Glo1 and we are currently identifying target proteins preferentially glycated by dicarbonyl compounds.Our results show that glyoxalase system is present in skin especially in the basal cells and is able to protect cellular proteins against oxidative damages. We expect that our study may contribute to decipher the role of glyoxalases in protein maintenance, which is a key element of cellular homeostasis during ageing, and to determine whether these enzymes could be targets for future anti-ageing skin strategies. Copyright © 2014. Published by Elsevier Inc.

  15. Auto-protective redox buffering systems in stimulated macrophages

    Directory of Open Access Journals (Sweden)

    Negre Olivier

    2002-03-01

    Full Text Available Abstract Background Macrophages, upon encounter with micro-organisms or stimulated by cytokines, produce various effector molecules aimed at destroying the foreign agents and protecting the organism. Reactive oxygen species (ROS and reactive nitrogen species (RNS are front line molecules exerting strong cytotoxic activities against micro-organisms and many cells, including macrophages themselves. Using cells of the murine macrophage cell line (RAW 264.7 stimulated in vitro with lipopolysaccharide (LPS and/or interferon (IFN-γ, which induce strong endogenous NO production, we examined by which mechanisms a fraction of activated macrophages protect themselves from nitrosative stress and manage to escape destruction? Results We observed that survivors (10–50% depending on the experiments had acquired a resistant phenotype being capable to survive when further exposed in vitro to an apoptosis inducing dose of the NO donor compound DETA-NO. These cells expressed an increased steady-state levels of Mn SOD, CuZn SOD and catalase mRNA (130–200%, together with an increased activity of the corresponding enzymes. Intracellular concentration of glutathione was also increased (× 3.5 fold at 6 hours, still maintained × 5.2 fold at 48 hours. Neither mRNA for glutathione peroxydase, γ-glutamylcysteine synthase and glutathione reductase, nor thioredoxine and thioredoxine reductase, were significantly modified. Additional experiments in which RAW 264.7 cells were stimulated with LPS and/or IFN-γ in the presence of relatively specific inhibitors of both Mn and Cu/Zn SOD, aminotriazol (ATZ catalase inhibitor and buthionine sulfoximine (BSO glutathione inhibitor, showed that inhibiting LPS-induced up-regulation of intracellular redox buffering systems also prevented acquisition of the resistant phenotype. Conclusions Our data suggest a direct causal relationship between survival of a fraction of macrophages and a up-regulation of key sets of auto-protective

  16. Routing Protection Scheme For Redundancy In Fiber Communication Systems

    Science.gov (United States)

    Werthman, Dean A.; Corke, Michael; Fitzgerald, Paul W.

    1990-01-01

    Redundancy in communication systems is vital for providing customer satisfaction and a cost effective network. If a line is cut in present systems, the traffic on that line must be routed to other channels while an emergency repair is made. If the operating company cannot provide the bandwidth to satisfy this rerouting, it must rent information capacity from its competitors. Presently, fiber is being installed in the metropolitan and subscriber loop networks, and consideration is being taken to provide redundancy in network reconfiguration to reduce fiber breakage problems. In a full duplex communication network, individual optical waveguides are utilized for transmission and reception of signals. Figure 1 illustrates a typical metropolitan network link from office to office. If a cable is severed by accident during construction work, discontinuity of service would result. When there are thousands of premium-paying customers at the other end of that cable, this situation can achieve crisis level immediately. In this paper details of a route protection or diversification scheme will be presented that will incorporate an intelligent fiber optic system that will automatically detect a cable fault and switch traffic to redundant fiber cables.

  17. [Characteristics of falls among free living elders].

    Science.gov (United States)

    González, G; Marín, P P; Pereira, G

    2001-09-01

    Falls by older adults are a frequent problem among ambulatory patients in primary care. To describe the prevalence and features of falls among elders consulting to an ambulatory Geriatric Clinic. Persons aged 60 years or more were surveyed about the number of falls in the preceding six months, the characteristics and consequences of each falls. Biopsychosocial characteristics were recorded and the Tinetti gait and balance test was performed in all patients reporting falls. In 104 (18.2%) of 571 clinical consultations, one or more falls were reported. Among patients who fell and provided complete data (n = 95), 64% reported one fall and 36% reported two or more, totaling 156 falls to analyze. The mean age of the patients with falls was 71.8 +/- 6.8 years. The functional and cognitive status was normal in 73 and 71.6% of cases respectively and 38% carried out periodical physical activity. Fifty seven percent of falls occurred outside of home, and an extrinsic factor was a precipitating cause in 55% of the falls. A post-fall syndrome appeared in 21% of cases and 2.6% resulted in fractures. Falling two or more times versus one time during the last six months was statistically associated with an age over 75, an absence of periodic physical activity, functional impairments, three or more chronic diseases, neurological diseases and with living alone, among other variables. Falls among elders occur mainly outside of home, in subjects older than 75 years old, functionally dependent and with an important involvement of extrinsic factors. Physical activity, as well as the control of environmental risks, could be protective factors against recurrent falls.

  18. Leisure-Time Physical Activity, Falls, and Fall Injuries in Middle-Aged Adults.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Courtney, Theodore K; Chang, Wen-Ruey; Lombardi, David A; Huang, Yueng-Hsiang; Brennan, Melanye J; Perry, Melissa J; Katz, Jeffrey N; Christiani, David C; Verma, Santosh K

    2015-12-01

    Although exercise and strength training have been shown to be protective against falls in older adults (aged 65 years and older), evidence for the role of leisure-time physical activity (LTPA) in the prevention of falls and resulting injuries in middle-aged adults (aged 45-64 years) is lacking. In the present study, we investigate the association between self-reported engagement in LTPA and the frequency of falls and fall-related injuries among middle-aged and older adults, while controlling for key sociodemographic and health characteristics. Nationally representative data from the 2010 U.S. Behavioral Risk Factor Surveillance Survey were analyzed in April 2014 to examine the number of adults aged ≥45 years who self-reported their fall experience in the previous 3 months and any injuries that resulted from those falls. We then evaluated the association between LTPA and self-reported falls and injuries across three age strata (45-54, 55-64, and ≥65 years). The two main self-reported outcome measures were (1) frequency of falls in the 3 months prior to the survey interview date and (2) the number of injuries resulting from these falls. Prevalence ratios (PRs) and 95% CIs were calculated using Poisson regression models with robust SEs. Of 340,680 survey participants aged ≥45 years, 70.7% reported engaging in LTPA, and 17% reported one or more falls. Among those reporting a fall within 3 months, 25.6% experienced one injurious fall (fall resulting in an injury) and 8.4% reported two or more injurious falls. Controlling for sociodemographic and health characteristics, among adults aged 45-54 years, those who engaged in LTPA were significantly less likely to report one fall (PR=0.90, 95% CI=0.81, 0.99); two or more falls (PR=0.84, 95% CI=0.77, 0.93); one injurious fall (PR=0.88, 95% CI=0.78, 0.99); and two or more injurious falls (PR=0.69, 95% CI=0.58, 0.83) than those who did not exercise. A similar protective effect of LTPA on reporting falls and injuries was

  19. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  20. Key issues concerning changes in the radiological protection system: some thoughts from the French Society for Radiation Protection (SFRP)

    International Nuclear Information System (INIS)

    Schieber, C.; Cordoliani, Y.S.

    2002-01-01

    In 1999, the International Radiological Protection Association (IRPA) asked for contributions to the debate on future changes to the radiological protection system proposed by the International Commission on Radiological Protection (ICRP). In response, the Board of the French Society for Radiation Protection (SFRP) created a working group to deal specifically with this issue. It met on several occasions between April and July and its findings were presented at the IRPA Congress in May 2000. They were also published in the French journal Radioprotection and in the British Journal of Radiological Protection. To further its discussions, the Board of the SFRP decided to create a second working group which became operational in September 2001. It has around 20 members representing the major players in the radiological protection field in France: authorities, experts and professionals from the nuclear, medical and research fields as well as one association representative (the list of members can be found at the end of this document). The working group was set up to produce proposals relating to the key issues likely to be raised, particularly by the ICRP, concerning the development of new radiological protection recommendations. The members of the working group analysed the ICRP memorandum published in the June 2001 edition of the Journal of Radiological Protection and used their own experience to determine what these key issues would be. The following issues were discussed: General thoughts on the new radiological protection system proposed by the ICRP, Individual and collective approaches to the radiological risk, Comparison with chemical risk management, Radiological protection of the environment, Changes in exposure levels and units of measurement. This paper, which has been approved by the Board of the SFRP, gives the main conclusions of the working group on the key issues in these areas. It is intended to reflect the various opinions expressed during the groups