WorldWideScience

Sample records for failure detection operating

  1. Fuel failure detection in operating reactors

    International Nuclear Information System (INIS)

    Seigel, B.; Hagen, H.H.

    1977-12-01

    Activity detectors in commercial BWRs and PWRs are examined to determine their capability to detect a small number of fuel rod failures during reactor operation. The off-gas system radiation monitor in a BWR and the letdown line radiation monitor in a PWR are calculated to have this capability, and events are cited that support this analysis. Other common detectors are found to be insensitive to small numbers of fuel failures. While adequate detectors exist for normal and transient operation, those detectors would not perform rapidly enough to be useful during accidents; in most accidents, however, primary system sensors (pressure, temperature, level) would provide adequate warning. Advanced methods of fuel failure detection are mentioned

  2. Clad failure detection in G 3 - operational feedback

    International Nuclear Information System (INIS)

    Plisson, J.

    1964-01-01

    After briefly reviewing the role and the principles of clad failure detection, the author describes the working conditions and the conclusions reached after 4 years operation of this installation on the reactor G 3. He mentions also the modifications made to the original installation as well as the tests carried out and the experiments under way. (author) [fr

  3. Operation experiences of JOYO fuel failure detection system

    International Nuclear Information System (INIS)

    Tamura, Seiji; Hikichi, Takayoshi; Rindo, Hiroshi.

    1982-01-01

    Monitoring of fuel failure in the experimental fast reactor JOYO is provided by two different methods, which are cover gas monitoring (FFDCGM) by means of a precipitator, and delayed neutron monitoring (FFDDNM) by means of neutron detectors. The interpretation of signals which were obtained during the reactor operation for performance testings, was performed. The countrate of the CGM is approximately 120 cps at 75MW operation, whose sources are due to Ne 23 , Ar 41 , and Na 24 . And the countrate of the DNM is approximately 2300 cps at 75MW operation which is mainly due to leakage neutron from the core. With those background of the systems, alarm level for monitoring was set at several times of each background level. The reactor has been operated for 5 years, the burn-up of the fuel is 40,000 MWD/T at the most. No trace of any fuel failure has been observed. The fact is also proven by the results of cover gas and sodium sampling analysis. In order to evaluate sensitivity of the FFD systems, a preliminary simulation study has been performed. According to the results, a signal level against one pin failure of 0.5 mm 2 hole may exceed the alarm level of the FFDCGM system. (author)

  4. Failure detection studies by layered neural network

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Seker, S.; Turkcan, E.

    1991-06-01

    Failure detection studies by layered neural network (NN) are described. The particular application area is an operating nuclear power plant and the failure detection is of concern as result of system surveillance in real-time. The NN system is considered to be consisting of 3 layers, one of which being hidden, and the NN parameters are determined adaptively by the backpropagation (BP) method, the process being the training phase. Studies are performed using the power spectra of the pressure signal of the primary system of an operating nuclear power plant of PWR type. The studies revealed that, by means of NN approach, failure detection can effectively be carried out using the redundant information as well as this is the case in this work; namely, from measurement of the primary pressure signals one can estimate the primary system coolant temperature and hence the deviation from the operational temperature state, the operational status identified in the training phase being referred to as normal. (author). 13 refs.; 4 figs.; 2 tabs

  5. Fuel failure detection and location methods in CAGRs

    International Nuclear Information System (INIS)

    Harris, A.M.

    1982-06-01

    The release of fission products from AGR fuel failures and the way in which the signals from such failures must be detected against the background signal from uranium contamination of the fuel is considered. Theoretical assessments of failure detection are used to show the limitations of the existing Electrostatic Wire Precipitator Burst Can Detection system (BCD) and how its operating parameters can be optimised. Two promising alternative methods, the 'split count' technique and the use of iodine measurements, are described. The results of a detailed study of the mechanical and electronic performance of the present BCD trolleys are given. The limited experience of detection and location of two fuel failures in CAGR using conventional and alternative methods is reviewed. The larger failure was detected and located using the conventional BCD equipment with a high confidence level. It is shown that smaller failures may not be easy to detect and locate using the current BCD equipment, and the second smaller failure probably remained in the reactor for about a year before it was discharged. The split count technique used with modified BCD equipment was able to detect the smaller failure after careful inspection of the data. (author)

  6. A multivariate statistical methodology for detection of degradation and failure trends using nuclear power plant operational data

    International Nuclear Information System (INIS)

    Samanta, P.K.; Teichmann, T.

    1990-01-01

    In this paper, a multivariate statistical method is presented and demonstrated as a means for analyzing nuclear power plant transients (or events) and safety system performance for detection of malfunctions and degradations within the course of the event based on operational data. The study provides the methodology and illustrative examples based on data gathered from simulation of nuclear power plant transients (due to lack of easily accessible operational data). Such an approach, once fully developed, can be used to detect failure trends and patterns and so can lead to prevention of conditions with serious safety implications

  7. Clad failure detection in G 3 - operational feedback; Detection de rupture de gaines G 3 - experience d'exploitation

    Energy Technology Data Exchange (ETDEWEB)

    Plisson, J [CEA Marcoule, Centre de Production de Plutonium, 30 (France)

    1964-07-01

    After briefly reviewing the role and the principles of clad failure detection, the author describes the working conditions and the conclusions reached after 4 years operation of this installation on the reactor G 3. He mentions also the modifications made to the original installation as well as the tests carried out and the experiments under way. (author) [French] Apres un rappel succinct du role et des principes de la detection de rupture de gaines, l'auteur fait un expose des conditions de fonctionnement et de l'experience tiree de 4 annees d'exploitation de cette installation sur le reacteur G 3. Il signale au passage les modifications apportees a l'installation d'origine, ainsi que les essais effectues, et les experiences en cours.

  8. In-line 3D print failure detection using computer vision

    DEFF Research Database (Denmark)

    Lyngby, Rasmus Ahrenkiel; Wilm, Jakob; Eiríksson, Eyþór Rúnar

    2017-01-01

    Here we present our findings on a novel real-time vision system that allows for automatic detection of failure conditions that are considered outside of nominal operation. These failure modes include warping, build plate delamination and extrusion failure. Our system consists of a calibrated came...

  9. Failure detection in high-performance clusters and computers using chaotic map computations

    Science.gov (United States)

    Rao, Nageswara S.

    2015-09-01

    A programmable media includes a processing unit capable of independent operation in a machine that is capable of executing 10.sup.18 floating point operations per second. The processing unit is in communication with a memory element and an interconnect that couples computing nodes. The programmable media includes a logical unit configured to execute arithmetic functions, comparative functions, and/or logical functions. The processing unit is configured to detect computing component failures, memory element failures and/or interconnect failures by executing programming threads that generate one or more chaotic map trajectories. The central processing unit or graphical processing unit is configured to detect a computing component failure, memory element failure and/or an interconnect failure through an automated comparison of signal trajectories generated by the chaotic maps.

  10. Knowledge representation methods for early failure detection

    International Nuclear Information System (INIS)

    Scherer, K.P.; Stiller, P.

    1990-01-01

    To supervise technical processes like nuclear power plants, it is very important to detect failure modes in an early stage. In the nuclear research center at Karlsruhe an expert system is developed, embedded in a computer network of autonomous computers, which are used for intelligent prepocessing. Events, process data and actual parameter values are stored in slots of special frames in the knowledge base of the expert system. Both rule based and fact based knowledge representations are employed to generate cause consequence chains of failure states. By on-line surveillance of the reactor process, the slots of the frames are dynamically actualized. Immediately after the evaluation, the inference engine starts in the special domain experts (triggered by metarules from a manager) and detects the correspondend failures or anomaly state. Matching the members of the chain and regarding a catalogue of instructions and messages, what is to do by the operator, future failure states can be estimated and propagation can be prohibited. That means qualitative failure prediction based on cause consequence in the static part of the knowledge base. Also, a time series of physical data can be used to predict on analytical way future process state and to continue such a theoretical propagation with matching the cause consuquence chain

  11. System to detect and protect a failure during start-up of pumping-up; Yosui shidochu no jikokenshutsu hogo hoshiki

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, H. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-12-10

    Development was made on a method to detect and protect a failure in a power generation motor operating at a rotation speed other than the rated speed, such as in start-up of pumping-up. Such a failure may not be detected from the ordinary frequency characteristics because the failure current due to short circuit or earth failure is lower than the rated frequency. An idea was conceived to detect flow of low frequency failure current on the armature side by detecting change in the field current being a phenomenal change in the armature current. To realize the idea, the simulation circuits of the parent and child motors of the power generation motors were modeled and verified. The following results were obtained from the verification of a three-phase short circuit failure: when the field current is constant, the failure current is nearly constant regardless of the operating frequency; the failure current flows into the field circuit; because the trajectory of the low frequency overcurrent in the main circuit flowing in case of operation in a low frequency zone presents the similar trajectory to that in 60-Hz operation, the failure may be detected from variation in the field current; and the protection activity after the failure detection is to release the excitation, and attenuate the failure current. (NEDO)

  12. Triplexer Monitor Design for Failure Detection in FTTH System

    Science.gov (United States)

    Fu, Minglei; Le, Zichun; Hu, Jinhua; Fei, Xia

    2012-09-01

    Triplexer was one of the key components in FTTH systems, which employed an analog overlay channel for video broadcasting in addition to bidirectional digital transmission. To enhance the survivability of triplexer as well as the robustness of FTTH system, a multi-ports device named triplexer monitor was designed and realized, by which failures at triplexer ports can be detected and localized. Triplexer monitor was composed of integrated circuits and its four input ports were connected with the beam splitter whose power division ratio was 95∶5. By means of detecting the sampled optical signal from the beam splitters, triplexer monitor tracked the status of the four ports in triplexer (e.g. 1310 nm, 1490 nm, 1550 nm and com ports). In this paper, the operation scenario of the triplexer monitor with external optical devices was addressed. And the integrated circuit structure of the triplexer monitor was also given. Furthermore, a failure localization algorithm was proposed, which based on the state transition diagram. In order to measure the failure detection and localization time under the circumstance of different failed ports, an experimental test-bed was built. Experiment results showed that the detection time for the failure at 1310 nm port by the triplexer monitor was less than 8.20 ms. For the failure at 1490 nm or 1550 nm port it was less than 8.20 ms and for the failure at com port it was less than 7.20 ms.

  13. Learning from Failures in Operations

    DEFF Research Database (Denmark)

    Koch, Christian

    2005-01-01

    parallelism and fragmentation due to their predominantly quantitative complexity. It is suggested that a number of critical junctions occur in these processes and that obtaining quality and avoiding failures quite often requires a series of competent and situational operation management actions. An empirical...... product. The analysis showed that, among others, design review, project review, commencing and finalizing operations turned out to be critical junctions in the control of failures. Practical implications and improvements are discussed. The focus on critical junctions, points to supply chain management......This paper discusses failures and quality in operations in design and production of buildings. The importance of human action, interpretations and interactions in tackling complexity, fragmentation and disturbances in the building industry is underlined. Building processes encompass requisite...

  14. Error Detection and Error Classification: Failure Awareness in Data Transfer Scheduling

    Energy Technology Data Exchange (ETDEWEB)

    Louisiana State University; Balman, Mehmet; Kosar, Tevfik

    2010-10-27

    Data transfer in distributed environment is prone to frequent failures resulting from back-end system level problems, like connectivity failure which is technically untraceable by users. Error messages are not logged efficiently, and sometimes are not relevant/useful from users point-of-view. Our study explores the possibility of an efficient error detection and reporting system for such environments. Prior knowledge about the environment and awareness of the actual reason behind a failure would enable higher level planners to make better and accurate decisions. It is necessary to have well defined error detection and error reporting methods to increase the usability and serviceability of existing data transfer protocols and data management systems. We investigate the applicability of early error detection and error classification techniques and propose an error reporting framework and a failure-aware data transfer life cycle to improve arrangement of data transfer operations and to enhance decision making of data transfer schedulers.

  15. Filtering technique for detection and identification of measurement failures in nuclear power plants

    International Nuclear Information System (INIS)

    Racz, A.

    1989-11-01

    The basic requirement of the safe operation of nuclear power plants (NPP) is to have reliable information on all quantities that can be measured, monitored or controlled during the operation. Kalman filtering techniques have been applied for prompt detection and identification of failures in the measurement systems used in NPPs. Mathematical basis of Kalman filtering and various models applied to failure detection are overviewed. The applicability of some models are evaluated by real results of NPP measurements. A sample system for an NPP is suggested, based on several numerical tests. (R.P.) 23 refs.; 40 figs.; 2 tabs

  16. Method of detecting fuel failure in FBR type reactor and method of estimating fuel failure position

    International Nuclear Information System (INIS)

    Sonoda, Yukio; Tamaoki, Tetsuo

    1989-01-01

    Noise components in a normal state contained in detection signals from delayed neutron monitors disposed to a coolant inlet, etc. of an intermediate heat exchanger are forecast by self-recurring model and eliminated, and resultant detection signals are monitored thereby detecting fuel failure high sensitivity. Subsequently, the reactor is controlled to a low power operation state and a new self-recurring model to the detection signals from the delayed neutron monitors are prepared. Then, noise components in this state are removed and control rods near the delayed neutron monitors are extracted in a short stroke successively to examine the change of response of the delayed neutron monitors. Accordingly, the failed position for each of the fuels can be estimated at a level of one fuel assembly or a level of several assemblies containing the above-mentioned fuel assembly. Since the fuel failure can be detected at a high sensitivity and the position can be estimated, diffusion of abnormality can be prevented and plant shutdown for fuel exchange can be minimized. (I.S.)

  17. Bearing failure detection of micro wind turbine via power spectral density analysis for stator current signals spectrum

    Science.gov (United States)

    Mahmood, Faleh H.; Kadhim, Hussein T.; Resen, Ali K.; Shaban, Auday H.

    2018-05-01

    The failure such as air gap weirdness, rubbing, and scrapping between stator and rotor generator arise unavoidably and may cause extremely terrible results for a wind turbine. Therefore, we should pay more attention to detect and identify its cause-bearing failure in wind turbine to improve the operational reliability. The current paper tends to use of power spectral density analysis method of detecting internal race and external race bearing failure in micro wind turbine by estimation stator current signal of the generator. The failure detector method shows that it is well suited and effective for bearing failure detection.

  18. Improved GLR method to instrument failure detection

    International Nuclear Information System (INIS)

    Jeong, Hak Yeoung; Chang, Soon Heung

    1985-01-01

    The generalized likehood radio(GLR) method performs statistical tests on the innovations sequence of a Kalman-Buchy filter state estimator for system failure detection and its identification. However, the major drawback of the convensional GLR is to hypothesize particular failure type in each case. In this paper, a method to solve this drawback is proposed. The improved GLR method is applied to a PWR pressurizer and gives successful results in detection and identification of any failure. Furthmore, some benefit on the processing time per each cycle of failure detection and its identification can be accompanied. (Author)

  19. Development of failure detection system for gas-cooled reactor

    International Nuclear Information System (INIS)

    Feirreira, M.P.

    1990-01-01

    This work presents several kinds of Failure Detection Systems for Fuel Elements, stressing their functional principles and major applications. A comparative study indicates that the method of electrostatic precipitation of the fission gases Kr and Xe is the most efficient for fuel failure detection in gas-cooled reactors. A detailed study of the physical phenomena involved in electrostatic precipitation led to the derivation of an equation for the measured counting rate. The emission of fission products from the fuel and the ion recombination inside the chamber are evaluated. A computer program, developed to simulate the complete operation of the system, relates the counting rate to the concentration of Kr and Xe isotopes. The project of a mock-up is then presented. Finally, the program calculations are compared to experimental data, available from the literature, yielding a close agreement. (author)

  20. Analysis of failure and maintenance experiences of motor operated valves in a Finnish nuclear power plant

    International Nuclear Information System (INIS)

    Simola, K.; Laakso, K.

    1992-01-01

    Operating experiences from 1981 up to 1989 of totally 104 motor operated closing valves (MOV) in different safety systems at TVO I and II nuclear power units were analysed in a systematic way. The qualitative methods used were failure mode and effects analysis (FMEA) and maintenance effects and criticality analysis (MECA). The failure descriptions were obtained from power plant's computerized failure reporting system. The reported 181 failure events were reanalysed and sorted according to specific classifications developed for the MOV function. Filled FMEA and MECA sheets on individual valves were stored in a microcomputer data base for further analyses. Analyses were performed for the failed mechanical and electrical valve parts, ways of detection of failure modes, failure effects, and repair and unavailability times

  1. Rate based failure detection

    Science.gov (United States)

    Johnson, Brett Emery Trabun; Gamage, Thoshitha Thanushka; Bakken, David Edward

    2018-01-02

    This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or data paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.

  2. Failure detection by adaptive lattice modelling using Kalman filtering methodology : application to NPP

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1991-03-01

    Detection of failure in the operational status of a NPP is described. The method uses lattice form of the signal modelling established by means of Kalman filtering methodology. In this approach each lattice parameter is considered to be a state and the minimum variance estimate of the states is performed adaptively by optimal parameter estimation together with fast convergence and favourable statistical properties. In particular, the state covariance is also the covariance of the error committed by that estimate of the state value and the Mahalanobis distance formed for pattern comparison takes x 2 distribution for normally distributed signals. The failure detection is performed after a decision making process by probabilistic assessments based on the statistical information provided. The failure detection system is implemented in multi-channel signal environment of Borssele NPP and its favourable features are demonstrated. (author). 29 refs.; 7 figs

  3. Signal analysis for failure detection

    International Nuclear Information System (INIS)

    Parpaglione, M.C.; Perez, L.V.; Rubio, D.A.; Czibener, D.; D'Attellis, C.E.; Brudny, P.I.; Ruzzante, J.E.

    1994-01-01

    Several methods for analysis of acoustic emission signals are presented. They are mainly oriented to detection of changes in noisy signals and characterization of higher amplitude discrete pulses or bursts. The aim was to relate changes and events with failure, crack or wear in materials, being the final goal to obtain automatic means of detecting such changes and/or events. Performance evaluation was made using both simulated and laboratory test signals. The methods being presented are the following: 1. Application of the Hopfield Neural Network (NN) model for classifying faults in pipes and detecting wear of a bearing. 2. Application of the Kohonnen and Back Propagation Neural Network model for the same problem. 3. Application of Kalman filtering to determine time occurrence of bursts. 4. Application of a bank of Kalman filters (KF) for failure detection in pipes. 5. Study of amplitude distribution of signals for detecting changes in their shape. 6. Application of the entropy distance to measure differences between signals. (author). 10 refs, 11 figs

  4. Aircraft control surface failure detection and isolation using the OSGLR test. [orthogonal series generalized likelihood ratio

    Science.gov (United States)

    Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.

    1986-01-01

    The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.

  5. Development of Uranium-Carrying Ball method for calibration of fuel element failure detecting systems

    International Nuclear Information System (INIS)

    Liu Yupu; Bao Wanping; Lu Cungang

    1988-01-01

    A Uranium-Carrying Ball method used for the determination of sensitivity, stability of the fuel element failure detecting systems is developed. A special facility for transporting the ball can be carried out by the flow of the cooling water, so that the failure signal can be simulated. Five different types of the Uranium-Carrying Ball have been developed. Type-I to Type-IV may provide failure signal in terms of uranium quantity or exposure area of uranium. Type-V can be used to simulate micro-flaw and examine the detectability of various detective methods for this kind of defect, at the same time it is difficult for the delayed neutron detector to detect micro-flaw. The results of long-time irradiation and washing test show that the working life of the balls is satisfactory. Using the experimentel facility with the balls, detailed study of the capability of various fuel failure detecting systems have been conducted successfully. The operation is easy and safe, the accuracy of this method is higher than that of other methods, the nuclear fuel consumption as well as the radioactive contamination is low. At present, the research on the failure mechanism is being conducted by means of this method

  6. Expanded envelope concepts for aircraft control-element failure detection and identification

    Science.gov (United States)

    Weiss, Jerold L.; Hsu, John Y.

    1988-01-01

    The purpose of this effort was to develop and demonstrate concepts for expanding the envelope of failure detection and isolation (FDI) algorithms for aircraft-path failures. An algorithm which uses analytic-redundancy in the form of aerodynamic force and moment balance equations was used. Because aircraft-path FDI uses analytical models, there is a tradeoff between accuracy and the ability to detect and isolate failures. For single flight condition operation, design and analysis methods are developed to deal with this robustness problem. When the departure from the single flight condition is significant, algorithm adaptation is necessary. Adaptation requirements for the residual generation portion of the FDI algorithm are interpreted as the need for accurate, large-motion aero-models, over a broad range of velocity and altitude conditions. For the decision-making part of the algorithm, adaptation may require modifications to filtering operations, thresholds, and projection vectors that define the various hypothesis tests performed in the decision mechanism. Methods of obtaining and evaluating adequate residual generation and decision-making designs have been developed. The application of the residual generation ideas to a high-performance fighter is demonstrated by developing adaptive residuals for the AFTI-F-16 and simulating their behavior under a variety of maneuvers using the results of a NASA F-16 simulation.

  7. Detection and effects of pump low-flow operation

    International Nuclear Information System (INIS)

    Casada, D.A.; Greene, R.H.

    1993-01-01

    Operating experience and previous studies have shown that a significant cause of pump problems and failures can result from low- flow operation. Operation at low-flow rates can create unstable flows within the pump impeller and casing. This condition can result in an increased radial and axial thrust on the rotor, which in turn causes higher shaft stresses, increased shaft deflection, and potential bearing and mechanical seal problems. Two of the more serious results of low-flow pump operation are cavitation and recirculation. Cavitation is the formation and subsequent collapse of vapor bubbles in any flow that is at an ambient pressure less than the vapor pressure of the liquid medium. It is the collapse of these vapor bubbles against the metal surfaces of the impeller or casing that causes surface pitting, erosion, and deterioration. Pump recirculation more damaging than cavitation. If located at the impeller eye, recirculation damages the inlet areas of the casing. At the impeller tips, recirculation alters the outside diameter of the impeller. If recirculation occurs around impeller shrouds, it damages thrust bearings. Recirculation also erodes impellers, diffusers, and volutes and causes failure of mechanical seals and bearings. This paper reports on a utility pump failure caused by low-flow induced phenomena. ORNL is investigating the results of low-flow pump operations by evaluating the types of measurements and diagnostic techniques that are currently used by licensees to detect pump degradation. A new, enhanced application of motor current and power data analysis has been developed that uses a signal comparison methodology to produce an instability ratio indicative of normal or unstable flow conditions. Examples of this type of low-flow detection technique are presented in this paper along with a brief discussion of the various types of technologies currently being used by licensees to evaluate pump operation and determine possible degradation

  8. Failure position detection device for nuclear fuel rod

    International Nuclear Information System (INIS)

    Ishida, Takeshi; Higuchi, Shin-ichi; Ito, Masaru; Matsuda, Yasuhiko

    1987-01-01

    Purpose: To easily detect failure position of a nuclear fuel rod by relatively moving an air-tightly shielded detection portion to a fuel rod. Constitution: For detecting the failure position of a leaked fuel assembly, the fuel assembly is dismantled and a portion of withdrawn fuel rod is air-tightly sealed with an inspection portion. The inside of the inspection portion is maintained at a pressure-reduced state. Then, in a case if failed openings are formed at a portion sealed by the inspection portion in the fuel rod, FP gases in the fuel rod are released based on the reduced pressure and the FP gases are detected in the detection portion. Accordingly, by relatively moving the detection portion to the fuel rod, the failure position can be detected. (Yoshino, Y.)

  9. Failure position detection device for nuclear fuel rod

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Takeshi; Higuchi, Shin-ichi; Ito, Masaru; Matsuda, Yasuhiko

    1987-03-24

    Purpose: To easily detect failure position of a nuclear fuel rod by relatively moving an air-tightly shielded detection portion to a fuel rod. Constitution: For detecting the failure position of a leaked fuel assembly, the fuel assembly is dismantled and a portion of withdrawn fuel rod is air-tightly sealed with an inspection portion. The inside of the inspection portion is maintained at a pressure-reduced state. Then, in a case if failed openings are formed at a portion sealed by the inspection portion in the fuel rod, FP gases in the fuel rod are released based on the reduced pressure and the FP gases are detected in the detection portion. Accordingly, by relatively moving the detection portion to the fuel rod, the failure position can be detected. (Yoshino, Y.).

  10. Penstock failure detection system at the 'Valsan' hydro power plant

    International Nuclear Information System (INIS)

    Georgescu, A M; Coşoiu, C I; Alboiu, N; Hlevca, D; Tataroiu, R; Popescu, O

    2012-01-01

    'Valsan' is a small Hydro Power Plant, 5 MW, situated at about 160 km north of Bucharest, Romania, on the small 'Valsan' river in a remote mountainous area. It is equipped with a single Francis turbine. The penstock is located in the access shaft of the HPP. 'Hidroelectrica', the Romanian company that operates the HPP, was trying to implement a remote penstock failure detection system. Starting from a classic hydraulic problem, the authors of the paper derived a method for failure detection and localization on the pipe. The method assumes the existence of 2 flow meters and 2 pressure transducers at the inlet and outlet of the pressurized pipe. Calculations have to be based on experimental values measured in a permanent regime for different values of the flow rate. The method was at first tested on a pipe, in the Hydraulic Laboratory of the Technical University of Civil Engineering Bucharest. Pipe failure was modelled by opening of a valve on a tee branch of the analyzed pipe. Experimental results were found to be in good agreement with theoretical ones. The penstock of the 'Valsan' HPP, was modelled in EPANET, in order to: i) test the method at a larger scale; ii) get the right flow and pressure transducers that are needed to implement it. At the request of 'Hidroelectrica' a routine that computes the efficiency of the turbine was added to the monitoring software. After the system was implemented, another series of measurements were performed at the site in order to validate it. Failure was modelled by opening an existing valve on a branch of the penstock. Detection of the failure was correct and almost instantaneous, while failure location was accurate within 5% of the total penstock length.

  11. Penstock failure detection system at the "Valsan" hydro power plant

    Science.gov (United States)

    Georgescu, A. M.; Coşoiu, C. I.; Alboiu, N.; Hlevca, D.; Tataroiu, R.; Popescu, O.

    2012-11-01

    "Valsan" is a small Hydro Power Plant, 5 MW, situated at about 160 km north of Bucharest, Romania, on the small "Valsan" river in a remote mountainous area. It is equipped with a single Francis turbine. The penstock is located in the access shaft of the HPP. "Hidroelectrica", the Romanian company that operates the HPP, was trying to implement a remote penstock failure detection system. Starting from a classic hydraulic problem, the authors of the paper derived a method for failure detection and localization on the pipe. The method assumes the existence of 2 flow meters and 2 pressure transducers at the inlet and outlet of the pressurized pipe. Calculations have to be based on experimental values measured in a permanent regime for different values of the flow rate. The method was at first tested on a pipe, in the Hydraulic Laboratory of the Technical University of Civil Engineering Bucharest. Pipe failure was modelled by opening of a valve on a tee branch of the analyzed pipe. Experimental results were found to be in good agreement with theoretical ones. The penstock of the "Valsan" HPP, was modelled in EPANET, in order to: i) test the method at a larger scale; ii) get the right flow and pressure transducers that are needed to implement it. At the request of "Hidroelectrica" a routine that computes the efficiency of the turbine was added to the monitoring software. After the system was implemented, another series of measurements were performed at the site in order to validate it. Failure was modelled by opening an existing valve on a branch of the penstock. Detection of the failure was correct and almost instantaneous, while failure location was accurate within 5% of the total penstock length.

  12. A failure detection and isolation system simulator

    International Nuclear Information System (INIS)

    Assumpcao Filho, E.O.; Nakata, H.

    1990-04-01

    A failure detection and isolation system (FDI) simulation program has been developed for IBM-PC microcomputers. The program, based on the sequential likelihood ratio testing method developed by A. Wald, was implemented with the Monte-Carlo technique. The calculated failure detection rate was favorably compared against the wind-tunnel experimental redundant temperature sensors. (author) [pt

  13. Detecting failure of climate predictions

    Science.gov (United States)

    Runge, Michael C.; Stroeve, Julienne C.; Barrett, Andrew P.; McDonald-Madden, Eve

    2016-01-01

    The practical consequences of climate change challenge society to formulate responses that are more suited to achieving long-term objectives, even if those responses have to be made in the face of uncertainty1, 2. Such a decision-analytic focus uses the products of climate science as probabilistic predictions about the effects of management policies3. Here we present methods to detect when climate predictions are failing to capture the system dynamics. For a single model, we measure goodness of fit based on the empirical distribution function, and define failure when the distribution of observed values significantly diverges from the modelled distribution. For a set of models, the same statistic can be used to provide relative weights for the individual models, and we define failure when there is no linear weighting of the ensemble models that produces a satisfactory match to the observations. Early detection of failure of a set of predictions is important for improving model predictions and the decisions based on them. We show that these methods would have detected a range shift in northern pintail 20 years before it was actually discovered, and are increasingly giving more weight to those climate models that forecast a September ice-free Arctic by 2055.

  14. Safety relevant failure mechanisms in the post-operational phase

    International Nuclear Information System (INIS)

    Mayer, Gerhard; Stiller, Jan Christopher; Roemer, Sarah

    2017-03-01

    When the 13"t"h amendment of the Atomic Energy Act came into force, eight Germ an nuclear power plant units had their power operating licences revoked and are now in the so-called post operation phase. Of the remaining nuclear power plants, one have by now also entered the post operation phase, with those left in operation bound for entering this phase sometime between now and the end of 2022. Therefore, failure mechanisms that are particularly relevant for post operation were to be identified and described in the frame of the present project. To do so, three major steps were taken: Firstly, recent national and international pertinent literature was evaluated to obtain indications of failure mechanisms in the post operation phase. It turned out that most of the national and international literature deals with the general procedure of the transition from power operation to decommissioning and dismantling. However, there were also some documents providing detailed indications of possible failure mechanisms in post operation. This includes e.g. the release of radioactive materials caused by the drop of containers, chemical impacts on systems important to safety in connection with decontamination work, and corrosion in connection with the storage of the core in the spent fuel pool, with the latter leading to the jamming of the fuel assemblies in the storage racks and a possible reduction of coolant circulation. In a second step, three safety analyses of pressurised water reactors prepared by the respective plant operators were evaluated to identify failure mechanisms based on systems engineering. The failure mechanisms that were found here include e.g. faults in the boric acid concentration of the reactor coolant, damage to the equipment airlock upon the unloading of Castor casks, leakages in connection with primary system decontamination, and the drop of packages holding radioactive residual materials or waste with subsequent mobilisation of radioactive aerosols

  15. Immunity-based detection, identification, and evaluation of aircraft sub-system failures

    Science.gov (United States)

    Moncayo, Hever Y.

    analyzed in this thesis. They showed to have an important effect on detection performance and are a critical aspect when designing the configuration of the AIS. The results presented in this thesis show that the AIS paradigm addresses directly the complexity and multi-dimensionality associated with a damaged aircraft dynamic response and provides the tools necessary for a comprehensive/integrated solution to the FDIE problem. Excellent detection, identification, and evaluation performance has been recorded for all types of failures considered. The implementation of the proposed AIS-based scheme can potentially have a significant impact on the safety of aircraft operation. The output information obtained from the scheme will be useful to increase pilot situational awareness and determine automated compensation.

  16. Artificial-neural-network-based failure detection and isolation

    Science.gov (United States)

    Sadok, Mokhtar; Gharsalli, Imed; Alouani, Ali T.

    1998-03-01

    This paper presents the design of a systematic failure detection and isolation system that uses the concept of failure sensitive variables (FSV) and artificial neural networks (ANN). The proposed approach was applied to tube leak detection in a utility boiler system. Results of the experimental testing are presented in the paper.

  17. The application of the detection filter to aircraft control surface and actuator failure detection and isolation

    Science.gov (United States)

    Bonnice, W. F.; Wagner, E.; Motyka, P.; Hall, S. R.

    1985-01-01

    The performance of the detection filter in detecting and isolating aircraft control surface and actuator failures is evaluated. The basic detection filter theory assumption of no direct input-output coupling is violated in this application due to the use of acceleration measurements for detecting and isolating failures. With this coupling, residuals produced by control surface failures may only be constrained to a known plane rather than to a single direction. A detection filter design with such planar failure signatures is presented, with the design issues briefly addressed. In addition, a modification to constrain the residual to a single known direction even with direct input-output coupling is also presented. Both the detection filter and the modification are tested using a nonlinear aircraft simulation. While no thresholds were selected, both filters demonstrated an ability to detect control surface and actuator failures. Failure isolation may be a problem if there are several control surfaces which produce similar effects on the aircraft. In addition, the detection filter was sensitive to wind turbulence and modeling errors.

  18. Detecting virological failure in HIVinfected Tanzanian children ...

    African Journals Online (AJOL)

    Background. The performance of clinical and immunological criteria to predict virological failure in HIV-infected children receiving antiretroviral therapy (ART) is not well documented. Objective. To determine the validity of clinical and immunological monitoring in detecting virological failure in children on ART. Methods.

  19. Renal failure after operation for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Olsen, P S; Schroeder, T; Perko, M

    1990-01-01

    Among 656 patients undergoing surgery for abdominal aortic aneurysm, 81 patients (12%) developed postoperative renal failure. Before operation hypotension and shock occurred in 88% of the patients with ruptured aneurysm, whereas none of the patients operated electively were hypotensive. Dialysis...... was performed in 32 patients, while the remaining 49 patients were managed without dialysis. Within 30 days after the operation 47 patients (58%) had died. There was no difference in mortality between patients in dialysis and patients managed without dialysis. Thirteen patients died during follow-up. In six...... cases the death was caused by renal failure only or in combination with failure of other organs. Analysis of the cumulative survival shows that, if the patients survive the postoperative period, their life expectancy is comparable to that of patients without renal complications....

  20. Failure Prediction And Detection In Cloud Datacenters

    Directory of Open Access Journals (Sweden)

    Purvil Bambharolia

    2017-09-01

    Full Text Available Cloud computing is a novel technology in the field of distributed computing. Usage of Cloud computing is increasing rapidly day by day. In order to serve the customers and businesses satisfactorily fault occurring in datacenters and servers must be detected and predicted efficiently in order to launch mechanisms to tolerate the failures occurred. Failure in one of the hosted datacenters may propagate to other datacenters and make the situation worse. In order to prevent such situations one can predict a failure proliferating throughout the cloud computing system and launch mechanisms to deal with it proactively. One of the ways to predict failures is to train a machine to predict failure on the basis of messages or logs passed between various components of the cloud. In the training session the machine can identify certain message patterns relating to failure of data centers. Later on the machine can be used to check whether a certain group of message logs follow such patterns or not. Moreover each cloud server can be defined by a state which indicates whether the cloud is running properly or is facing some failure. Parameters such as CPU usage memory usage etc. can be maintained for each of the servers. Using this parameters we can add a layer of detection where in we develop a decision tree based on these parameters which can classify whether the passed in parameters to the decision tree indicate failure state or proper state.

  1. Development of failure-detecting device for γ radioimmunoassay counter

    International Nuclear Information System (INIS)

    Shao Xianzhi; Zhang Bingfeng

    1997-01-01

    A failures-detecting device based on single chip microcomputer technique for detecting of failures of γ radioimmunoassay counter is developed. The device can output signals of variable amplitude and frequency similar to the pulse of γ particle for shooting problem parts of γ counter's detecting system. By automatically comparing the shapes and amplitudes of the two signals to and from an amplifier unit, the device can distinguish if the amplifier unit works normally. The differential-input amplifier circuit gives 0.1% accuracy for the measurement of the stability of high voltage. The pulse widen circuit of this device allows for middle speed A/D detecting of periodical low-frequency pulse waves of micro-second width. This device is used specifically for the maintaining and failure-detecting of γ radioimmunoassay counter

  2. Automatic patient respiration failure detection system with wireless transmission

    Science.gov (United States)

    Dimeff, J.; Pope, J. M.

    1968-01-01

    Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

  3. Device for detecting failure of reactor system

    International Nuclear Information System (INIS)

    Miyazawa, Tatsuo.

    1979-01-01

    Purpose: To make it possible to rapidly detect any failure in a reactor system prior to the leakage of coolants. Constitution: The dose of beta line is computed from the difference between the power of a detector for reacting with both beta and gamma lines and a detector for reacting only with gamma line to detect the failure of a reactor system, thereby to raise the detection speed and improve the detection accuracy. More specifically, a radiation detector A detects gamma and beta lines by means of piezoelectric elements. A radiation detector B caused the opening of the detector A to be covered with a metal, and detects only gamma line. The detected values of detectors A and B are amplified by an amplifier and applied to a rate meter and a counter, the values being converted into DC and introduced into a comparison circuit, where the outputs of the rate meter are compared with each other. When the difference is more than the predetermined range, it is supplied as output to an alarm circuit where an alarm signal is produced. (Nakamura, S.)

  4. Modification of fuel failure detection system at multi-purpose reactor RSG-GAS, BATAN

    International Nuclear Information System (INIS)

    Haruyama, Mitsuo; Shitomi, Hajime; Nakamura, Kiyoshi

    2003-03-01

    As one of the technical cooperation activity based on the Annex III, the Cooperation in the Area of Reactor Physics and Technology, of the Arrangement between the National Energy Agency (BATAN) and the Japan Atomic Energy Research Institute (JAERI), the modification of the Fuel Failure Detection System (FFDS) was carried out by the joint work at the Multi-purpose Reactor RSG-G.A. Siwabessy (RSG-GAS). The system takes the delayed neutron detection method. In normal state, as the background, it measures the gloss delayed neutron concentration emitted in the primary coolant from the fission product (FP) nuclides, which are resulted from a very small amount of fissile material contamination on the fuel plate surface at the fabrication process. When a failure happened at fuel cladding, FP leaks from the fuel meat into the primary coolant. The system shows so higher indication than at normal state, then, the fuel failure can be detected at the early stage and be minimized the damages to the reactor facility and to the environment. The system has been installed at first since November 1994 and applied for reactor operation. However, recently it is not easy to maintain the system for aging degradation and shortage of the spare units and the parts difficult to find in the markets. The modification of FFDS is required for safe and steady reactor operation. The design requirements of the modification are, - To save the system units currently used and the spares on hand as long as practicable, and/or - To replace the system units with those easy to maintain or to obtain at the markets. The modified system obtained around twice of higher sensitivity for delayed neutron detection than before and more reliable monitoring possibility with redundancy. The specification, installation, adjustment methods and characteristics of the modified system and the modus operandi of FFDS at high power reactor operation are described in this paper. (author)

  5. On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor.

    Science.gov (United States)

    Qin, Guoxiu; Chen, Xilin; Guo, Xiaoqing; Ni, Ning

    2016-08-01

    For early on-line detection of fuel rod failure, the key radionuclides useful in monitoring must leak easily from failing rods. Yield, half-life, and mass share of fission products that enter the primary coolant also need to be considered in on-line analyses. From all the nuclides that enter the primary coolant during fuel-rod failure, (135)Xe and (88)Kr were ultimately chosen as crucial for on-line monitoring of fuel-rod failure. A monitoring system for fuel-rod failure detection for pressurized water reactor (PWR) based on the LaBr3(Ce) detector was assembled and tested. The samples of coolant from the PWR were measured using the system as well as a HPGe γ-ray spectrometer. A comparison showed the method was feasible. Finally, the γ-ray spectra of primary coolant were measured under normal operations and during fuel-rod failure. The two peaks of (135)Xe (249.8keV) and (88)Kr (2392.1keV) were visible, confirming that the method is capable of monitoring fuel-rod failure on-line. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Sensor Failure Detection of FASSIP System using Principal Component Analysis

    Science.gov (United States)

    Sudarno; Juarsa, Mulya; Santosa, Kussigit; Deswandri; Sunaryo, Geni Rina

    2018-02-01

    In the nuclear reactor accident of Fukushima Daiichi in Japan, the damages of core and pressure vessel were caused by the failure of its active cooling system (diesel generator was inundated by tsunami). Thus researches on passive cooling system for Nuclear Power Plant are performed to improve the safety aspects of nuclear reactors. The FASSIP system (Passive System Simulation Facility) is an installation used to study the characteristics of passive cooling systems at nuclear power plants. The accuracy of sensor measurement of FASSIP system is essential, because as the basis for determining the characteristics of a passive cooling system. In this research, a sensor failure detection method for FASSIP system is developed, so the indication of sensor failures can be detected early. The method used is Principal Component Analysis (PCA) to reduce the dimension of the sensor, with the Squarred Prediction Error (SPE) and statistic Hotteling criteria for detecting sensor failure indication. The results shows that PCA method is capable to detect the occurrence of a failure at any sensor.

  7. Model-based failure detection for cylindrical shells from noisy vibration measurements.

    Science.gov (United States)

    Candy, J V; Fisher, K A; Guidry, B L; Chambers, D H

    2014-12-01

    Model-based processing is a theoretically sound methodology to address difficult objectives in complex physical problems involving multi-channel sensor measurement systems. It involves the incorporation of analytical models of both physical phenomenology (complex vibrating structures, noisy operating environment, etc.) and the measurement processes (sensor networks and including noise) into the processor to extract the desired information. In this paper, a model-based methodology is developed to accomplish the task of online failure monitoring of a vibrating cylindrical shell externally excited by controlled excitations. A model-based processor is formulated to monitor system performance and detect potential failure conditions. The objective of this paper is to develop a real-time, model-based monitoring scheme for online diagnostics in a representative structural vibrational system based on controlled experimental data.

  8. FFTF fuel failure detection and characterization by cover gas monitoring. Final report

    International Nuclear Information System (INIS)

    Miller, W.C.; Holt, F.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) will include a Fuel Failure Monitoring (FFM) System designed to detect, characterize, and locate fuel and absorber pin failures (i.e., cladding breaches) using a combination of delayed neutron detection, cover gas radioisotope monitoring, and gas tagging. During the past several years the Hanford Engineering Development Laboratory has been involved in the development, design, procurement, and installation of this integrated system. The paper describes one portion of the FFM System, the Cover Gas Monitoring System (CGMS), which has the primary function of fuel failure detection and characterization in the FFTF. By monitoring the various radioisotopes in the cover gas, the CGMS will both detect fuel and absorber pin failures and characterize those failures as to magnitude and severity

  9. Prediction of the time-dependent failure rate for normally operating components taking into account the operational history

    International Nuclear Information System (INIS)

    Vrbanic, I.; Simic, Z.; Sljivac, D.

    2008-01-01

    The prediction of the time-dependent failure rate has been studied, taking into account the operational history of a component used in applications such as system modeling in a probabilistic safety analysis in order to evaluate the impact of equipment aging and maintenance strategies on the risk measures considered. We have selected a time-dependent model for the failure rate which is based on the Weibull distribution and the principles of proportional age reduction by equipment overhauls. Estimation of the parameters that determine the failure rate is considered, including the definition of the operational history model and likelihood function for the Bayesian analysis of parameters for normally operating repairable components. The operational history is provided as a time axis with defined times of overhauls and failures. An example for demonstration is described with prediction of the future behavior for seven different operational histories. (orig.)

  10. Detection and effects of pump low-flow operation

    International Nuclear Information System (INIS)

    Casada, D.A.; Greene, R.H.

    1994-01-01

    Operating experience and previous studies performed for the Nuclear Plant Aging Research Program have shown that a significant cause of pump problems and failures can result from low-flow operation. Operation at low-flow rates can create unstable flows within the pump impeller and casing. This condition can result in an increased radial and axial thrust on the rotor, which in turn causes higher shaft stresses, increased shaft deflection, and potential bearing and mechanical seal problems. Two of the more serious results of low-flow pump operation are cavitation and recirculation. Both of these conditions can be characterized by crackling sounds that accompany a substantial increase in vibration and noise level, and a reduction in total head and output capacity. Cavitation is the formation and subsequent collapse of vapor bubbles in any flow that is at an ambient pressure less than the vapor pressure of the liquid medium. It is the collapse of these vapor bubbles against the metal surfaces of the impeller or casing that causes surface pitting, erosion, and deterioration. Pump recirculation, reversal of a portion of the flow back through the impeller, can be potentially more damaging than cavitation. If located at the impeller eye, recirculation damages the inlet areas of the casing. At the impeller tips, recirculation alters the outside diameter of the impeller. If recirculation occurs around impeller shrouds, it damages thrust bearings. Recirculation also erodes impellers, diffusers, and volutes and causes failure of mechanical seals and bearings. This paper reports on a utility pump failure cause by low-flow induced phenomena. ORNL has continued to investigate the results of low-flow pump operations by evaluating the types of measurements and diagnostic techniques that are currently used by licensees to detect pump degradation

  11. Contribution to the physical study of sheath failure detections

    International Nuclear Information System (INIS)

    Mangin, Jean-Paul

    1968-11-01

    As the study of an installation aimed at the detection of sheath failure requires the knowledge of a great number of data related to all the fields of nuclear technology (fission mechanisms, sheath failure mechanisms, recoil of fission products, distribution of the heat transfer fluid in the reactor, techniques of measurement of beta and gamma neutrons, nuclear safety, and so on), this report aims at highlighting some specific issues, more particularly those related to sensors based on delayed neutrons. After having recalled the principles of sheath failure detection, the author presents the various aspects of the study of the formation of fission products and of their passage into the heat transfer fluid: detection by using delayed neutrons, detection by electrostatic collection, passage of fuel fission products into the coolant (recoil, corrosion, gaseous diffusion in the fuel), formation of fission products in the fuel (fission product efficiency). He reports the study of the transport of fission products by the coolant from their place of birth to the place of measurement. He presents the system of measurement by detection of delayed neutrons and by electrostatic collection, reports a sensitivity calculation, a background noise assessment, the determination of detection threshold, and the application of sensitivity and detection thresholds calculations [fr

  12. Design of fuel failure detection system for multipurpose reactor GA. Siwabessy

    International Nuclear Information System (INIS)

    Sujalmo Saiful; Kuntoro Iman; Sato, Mitsugu; Isshiki, Masahiko.

    1992-01-01

    A fuel failure detection system (FFDS) has been designed for the Reactor GA. Siwabessy. The FFDS is aimed to detect fuel failure by observing delayed neutron released by fission products such as N-17, I-137, Br-87 and Br-88 in the primary cooling system. The delayed neutrons will be detected by using four neutron detectors, type BF-3, which are located inside a Sampling Tank. The detector location has been determined and the location is associated with the transit time from the reactor core outlet to the Sampling Tank, which is approximately 60 seconds. The neutron detection efficiency was calculated by using a computer code named MORSE. The FFDS has the capability to detect as quickly as possible, even a small failure of a fuel element occurring in the reactor core. Therefore the presence of FFDS in a reactor must be considered, in order to prevent further progress if the fuel failure occurs. (author)

  13. Proof-testing strategies induced by dangerous detected failures of safety-instrumented systems

    International Nuclear Information System (INIS)

    Liu, Yiliu; Rausand, Marvin

    2016-01-01

    Some dangerous failures of safety-instrumented systems (SISs) are detected almost immediately by diagnostic self-testing as dangerous detected (DD) failures, whereas other dangerous failures can only be detected by proof-testing, and are therefore called dangerous undetected (DU) failures. Some items may have a DU- and a DD-failure at the same time. After the repair of a DD-failure is completed, the maintenance team has two options: to perform an insert proof test for DU-failure or not. If an insert proof test is performed, it is necessary to decide whether the next scheduled proof test should be postponed or performed at the scheduled time. This paper analyzes the effects of different testing strategies on the safety performance of a single channel of a SIS. The safety performance is analyzed by Petri nets and by approximation formulas and the results obtained by the two approaches are compared. It is shown that insert testing improves the safety performance of the channel, but the feasibility and cost of the strategy may be a hindrance to recommend insert testing. - Highlights: • Identify the tests induced by detected failures. • Model the testing strategies following DD-failures. • Propose analytical formulas for effects of strategies. • Simulate and verify the proposed models.

  14. Circuit breaker operation and potential failure modes during an earthquake

    International Nuclear Information System (INIS)

    Lambert, H.E.; Budnitz, R.J.

    1987-01-01

    This study addresses the effect of a strong-motion earthquake on circuit breaker operation. It focuses on the loss of offsite power (LOSP) transient caused by a strong-motion earthquake at the Zion Nuclear Power Plant. This paper also describes the operator action necessary to prevent core melt if the above circuit breaker failure modes occur simultaneously on three 4.16 KV buses. Numerous circuit breakers important to plant safety, such as circuit breakers to diesel generators and engineered safety systems (ESS), must open and/or close during this transient while strong motion is occurring. Potential seismically-induced circuit-breaker failures modes were uncovered while the study was conducted. These failure modes include: circuit breaker fails to close; circuit breaker trips inadvertently; circuit breaker fails to reclose after trip. The causes of these failure modes include: Relay chatter causes the circuit breaker to trip; Relay chatter causes anti-pumping relays to seal-in which prevents automatic closure of circuit breakers; Load sequencer failures. The incorporation of these failure modes as well as other instrumentation and control failures into a limited scope seismic probabilistic risk assessment is also discussed in this paper

  15. Incipient failure detection of space shuttle main engine turbopump bearings using vibration envelope detection

    Science.gov (United States)

    Hopson, Charles B.

    1987-01-01

    The results of an analysis performed on seven successive Space Shuttle Main Engine (SSME) static test firings, utilizing envelope detection of external accelerometer data are discussed. The results clearly show the great potential for using envelope detection techniques in SSME incipient failure detection.

  16. Orthogonal series generalized likelihood ratio test for failure detection and isolation. [for aircraft control

    Science.gov (United States)

    Hall, Steven R.; Walker, Bruce K.

    1990-01-01

    A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.

  17. Project configured supply networks: Governance of delivery and failures in operations

    DEFF Research Database (Denmark)

    Koch, Christian

    2008-01-01

    of delivery types; parts, components and subsystems. The project configuration and orchestrated governance forms are not always successful, and failures emerge. The paper aims at studying governance forms in delivery networks using operational failures as litmus. Operation management approaches is used...... failures occurred during three month observation. The costs were 8 pct. of the production budget. None of the mobilised governance forms fully prevented failures, especially subsystem delivery and internal integration was underperforming.......  Supply networks in complex B2B- construction deliver knowledge, materials, components, subsystems, competences, workforce and management. The delivery network and its governance forms are partly permanent, partly project specific. Integration upstream varies by project, constituting a range...

  18. Multidrug-resistant tuberculosis treatment failure detection depends on monitoring interval and microbiological method

    Science.gov (United States)

    White, Richard A.; Lu, Chunling; Rodriguez, Carly A.; Bayona, Jaime; Becerra, Mercedes C.; Burgos, Marcos; Centis, Rosella; Cohen, Theodore; Cox, Helen; D'Ambrosio, Lia; Danilovitz, Manfred; Falzon, Dennis; Gelmanova, Irina Y.; Gler, Maria T.; Grinsdale, Jennifer A.; Holtz, Timothy H.; Keshavjee, Salmaan; Leimane, Vaira; Menzies, Dick; Milstein, Meredith B.; Mishustin, Sergey P.; Pagano, Marcello; Quelapio, Maria I.; Shean, Karen; Shin, Sonya S.; Tolman, Arielle W.; van der Walt, Martha L.; Van Deun, Armand; Viiklepp, Piret

    2016-01-01

    Debate persists about monitoring method (culture or smear) and interval (monthly or less frequently) during treatment for multidrug-resistant tuberculosis (MDR-TB). We analysed existing data and estimated the effect of monitoring strategies on timing of failure detection. We identified studies reporting microbiological response to MDR-TB treatment and solicited individual patient data from authors. Frailty survival models were used to estimate pooled relative risk of failure detection in the last 12 months of treatment; hazard of failure using monthly culture was the reference. Data were obtained for 5410 patients across 12 observational studies. During the last 12 months of treatment, failure detection occurred in a median of 3 months by monthly culture; failure detection was delayed by 2, 7, and 9 months relying on bimonthly culture, monthly smear and bimonthly smear, respectively. Risk (95% CI) of failure detection delay resulting from monthly smear relative to culture is 0.38 (0.34–0.42) for all patients and 0.33 (0.25–0.42) for HIV-co-infected patients. Failure detection is delayed by reducing the sensitivity and frequency of the monitoring method. Monthly monitoring of sputum cultures from patients receiving MDR-TB treatment is recommended. Expanded laboratory capacity is needed for high-quality culture, and for smear microscopy and rapid molecular tests. PMID:27587552

  19. Statistical analysis of operating efficiency and failures of a medical linear accelerator for ten years

    International Nuclear Information System (INIS)

    Ju, Sang Gyu; Huh, Seung Jae; Han, Young Yih

    2005-01-01

    To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2100C over a ten year period were retrospectively analyzed. The failures were classified according to the involved functional subunits, with each class rated into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for 20% of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and 83% of the expected values, respectively. The operating efficiency was maintained at 95% or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. More rigorous equipment maintenance is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the quality of patient treatment

  20. Detection of sensor failures in nuclear plants using analytic redundancy

    International Nuclear Information System (INIS)

    Kitamura, M.

    1980-01-01

    A method for on-line, nonperturbative detection and identification of sensor failures in nuclear power plants was studied to determine its feasibility. This method is called analytic redundancy, or functional redundancy. Sensor failure has traditionally been detected by comparing multiple signals from redundant sensors, such as in two-out-of-three logic. In analytic redundancy, with the help of an assumed model of the physical system, the signals from a set of sensors are processed to reproduce the signals from all system sensors

  1. Filter design for failure detection and isolation in the presence of modeling errors and disturbances

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Stoustrup, Jakob

    1996-01-01

    The design problem of filters for robust failure detection and isolation, (FDI) is addressed in this paper. The failure detection problem will be considered with respect to both modeling errors and disturbances. Both an approach based on failure detection observers as well as an approach based...

  2. Detection of Failure in Asynchronous Motor Using Soft Computing Method

    Science.gov (United States)

    Vinoth Kumar, K.; Sony, Kevin; Achenkunju John, Alan; Kuriakose, Anto; John, Ano P.

    2018-04-01

    This paper investigates the stator short winding failure of asynchronous motor also their effects on motor current spectrums. A fuzzy logic approach i.e., model based technique possibly will help to detect the asynchronous motor failure. Actually, fuzzy logic similar to humanoid intelligent methods besides expected linguistic empowering inferences through vague statistics. The dynamic model is technologically advanced for asynchronous motor by means of fuzzy logic classifier towards investigate the stator inter turn failure in addition open phase failure. A hardware implementation was carried out with LabVIEW for the online-monitoring of faults.

  3. Fuzzy modeling of analytical redundancy for sensor failure detection

    International Nuclear Information System (INIS)

    Tsai, T.M.; Chou, H.P.

    1991-01-01

    Failure detection and isolation (FDI) in dynamic systems may be accomplished by testing the consistency of the system via analytically redundant relations. The redundant relation is basically a mathematical model relating system inputs and dissimilar sensor outputs from which information is extracted and subsequently examined for the presence of failure signatures. Performance of the approach is often jeopardized by inherent modeling error and noise interference. To mitigate such effects, techniques such as Kalman filtering, auto-regression-moving-average (ARMA) modeling in conjunction with probability tests are often employed. These conventional techniques treat the stochastic nature of uncertainties in a deterministic manner to generate best-estimated model and sensor outputs by minimizing uncertainties. In this paper, the authors present a different approach by treating the effect of uncertainties with fuzzy numbers. Coefficients in redundant relations derived from first-principle physical models are considered as fuzzy parameters and on-line updated according to system behaviors. Failure detection is accomplished by examining the possibility that a sensor signal occurred in an estimated fuzzy domain. To facilitate failure isolation, individual FDI monitors are designed for each interested sensor

  4. Operational planning optimization of steam power plants considering equipment failure in petrochemical complex

    International Nuclear Information System (INIS)

    Luo, Xianglong; Zhang, Bingjian; Chen, Ying; Mo, Songping

    2013-01-01

    Highlights: ► We develop a systematic programming methodology to address equipment failure. ► We classify different operation conditions into real periods and virtual periods. ► The formulated MILP models guarantee cost reduction and enough operation safety. ► The consideration of reserving operation redundancy is effective. - Abstract: One or more interconnected steam power plants (SPPs) are constructed in a petrochemical complex to supply utility energy to the process. To avoid large economic penalties or process shutdowns, these SPPs should be flexible and reliable enough to meet the process energy requirement under varying conditions. Unexpected utility equipment failure is inevitable and difficult to be predicted. Most of the conventional methods are based on the assumption that SPPs do not experience any kind of equipment failure. Unfortunately, a process shutdown cannot be avoided when equipment fails unexpectedly. In this paper, a systematic methodology is presented to minimize the total cost under normal conditions while reserving enough flexibility and safety for unexpected equipment failure conditions. The proposed method transforms the different conditions into real periods to indicate normal scenarios and virtual periods to indicate unexpected equipment failure scenarios. The optimization strategy incorporating various operation redundancy scheduling, the transition constraints from equipment failure conditions to normal conditions, and the boiler load increase behavior modeling are presented to save cost and guarantee operation safety. A detailed industrial case study shows that the proposed systematic methodology is effective and practical in coping with equipment failure conditions with only few additional cost penalties

  5. Device for detecting imminent failure of high-dielectric stress capacitors. [Patent application

    Science.gov (United States)

    McDuff, G.G.

    1980-11-05

    A device is described for detecting imminent failure of a high-dielectric stress capacitor utilizing circuitry for detecting pulse width variations and pulse magnitude variations. Inexpensive microprocessor circuitry is utilized to make numerical calculations of digital data supplied by detection circuitry for comparison of pulse width data and magnitude data to determine if preselected ranges have been exceeded, thereby indicating imminent failure of a capacitor. Detection circuitry may be incorporated in transmission lines, pulse power circuitry, including laser pulse circuitry or any circuitry where capacitors or capacitor banks are utilized.

  6. Detection of wood failure by image processing method: influence of algorithm, adhesive and wood species

    Science.gov (United States)

    Lanying Lin; Sheng He; Feng Fu; Xiping Wang

    2015-01-01

    Wood failure percentage (WFP) is an important index for evaluating the bond strength of plywood. Currently, the method used for detecting WFP is visual inspection, which lacks efficiency. In order to improve it, image processing methods are applied to wood failure detection. The present study used thresholding and K-means clustering algorithms in wood failure detection...

  7. Operating experience feedback report: Service water system failures and degradations: Volume 3

    International Nuclear Information System (INIS)

    Lam, P.; Leeds, E.

    1988-11-01

    A comprehensive review and evaluation of service water system failures and degradations observed in operating events in light water reactors from 1980 to 1987 has been conducted. The review and evaluation focused on the identification of causes of system failures and degradations, the adequacy of corrective actions implemented and planned, and the safety significance of the operating events. The results of this review and evaluation indicate that the service water system failures and degradations have significant safety implications. These system failures and degradations are attributable to a great variety of causes, and have adverse impact on a large number of safety-related systems and components which are required to mitigate reactor accidents. Specifically, the causes of failures and degradations include various fouling mechanisms (sediment deposition, biofouling, corrosion and erosion, pipe coating failure, calcium carbonate, foreign material and debris intrusion); single failures and other design deficiencies; flooding; multiple equipment failures; personnel and procedural errors; and seismic deficiencies. Systems and components adversely impacted by a service water system failure or degradation include the component cooling water system, emergency diesel generators, emergency core cooling system pumps and heat exchangers, the residual heat removal system, containment spray and fan coolers, control room chillers, and reactor building cooling units. 44 refs., 10 figs., 5 tabs

  8. Investigation of component failure rates for pulsed versus steady state tokamak operation

    International Nuclear Information System (INIS)

    Cadwallader, L.C.

    1992-07-01

    This report presents component failure rate data sources applicable to magnetic fusion systems, and defines multiplicative factors to adjust these data for specific use on magnetic fusion experiment designs. The multipliers address both long pulse and steady state tokamak operation. Thermal fatigue and radiation damage are among the leading reasons for large multiplier values in pulsed operation applications. Field failure rate values for graphite protective tiles are presented, and beryllium tile failure rates in laboratory testing are also given. All of these data can be used for reliability studies, safety analyses, design tradeoff studies, and risk assessments

  9. Studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Hayashi, S.H.; Harasawa, S.; Tomura, K.

    1992-01-01

    Studies on fuel failure detection have been made since 1986 in Rikkyo Research Reactor. One of the methods is the monitoring of the trace concentration of fission products appearing in the air on the surface of the water tank of the reactor. The interested radionuclides here are 89 Rb and 138 Cs, which are the daughter nuclides of the FP rare gas nuclides, 89 Kr and 138 Xe, respectively and have the half lives of 15.2 min and 32.2 min respectively. They are detected on a filter paper attached on a conventional dust sampler, by sucking the air of the surface of the water for 15 ∼ 30 min during reactor operation (100 kW). In this presentation are reported the results of an attempt to increase the sensitivity of detecting these nuclides by introducing nitrogen gas bubbles into the water. The bubbling of the gas increased the sensitivity as much as several times compared with the case without bubbling. These measurements are giving us the 'background' concentration, the order of which is almost unchanged for these several years, --in 10 -6 Bq/cm 3 . The origin of these nuclides is considered to be not from the fuel but from the uranium contained as an impurity in the reactor material in the core. (author)

  10. A real-time expert system for nuclear power plant failure diagnosis and operational guide

    International Nuclear Information System (INIS)

    Naito, N.; Sakuma, A.; Shigeno, K.; Mori, N.

    1987-01-01

    A real-time expert system (DIAREX) has been developed to diagnose plant failure and to offer a corrective operational guide for boiling water reactor (BWR) power plants. The failure diagnosis model used in DIAREX was systematically developed, based mainly on deep knowledge, to cover heuristics. Complex paradigms for knowledge representation were adopted, i.e., the process representation language and the failure propagation tree. The system is composed of a knowledge base, knowledge base editor, preprocessor, diagnosis processor, and display processor. The DIAREX simulation test has been carried out for many transient scenarios, including multiple failures, using a real-time full-scope simulator modeled after the 1100-MW(electric) BWR power plant. Test results showed that DIAREX was capable of diagnosing a plant failure quickly and of providing a corrective operational guide with a response time fast enough to offer valuable information to plant operators

  11. Real time failure detection in unreinforced cementitious composites with triboluminescent sensor

    International Nuclear Information System (INIS)

    Olawale, David O.; Kliewer, Kaitlyn; Okoye, Annuli; Dickens, Tarik J.; Uddin, Mohammed J.; Okoli, Okenwa I.

    2014-01-01

    The in-situ triboluminescent optical fiber (ITOF) sensor has an integrated sensing and transmission component that converts the energy from damage events like impacts and crack propagation into optical signals that are indicative of the magnitude of damage in composite structures like concrete bridges. Utilizing the triboluminescence (TL) property of ZnS:Mn, the ITOF sensor has been successfully integrated into unreinforced cementitious composite beams to create multifunctional smart structures with in-situ failure detection capabilities. The fabricated beams were tested under flexural loading, and real time failure detection was made by monitoring the TL signals generated by the integrated ITOF sensor. Tested beam samples emitted distinctive TL signals at the instance of failure. In addition, we report herein a new and promising approach to damage characterization using TL emission profiles. Analysis of TL emission profiles indicates that the ITOF sensor responds to crack propagation through the beam even when not in contact with the crack. Scanning electron microscopy analysis indicated that fracto-triboluminescence was responsible for the TL signals observed at the instance of beam failure. -- Highlights: • Developed a new approach to triboluminescence (TL)-based sensing with ZnS:Mn. • Damage-induced excitation of ZnS:Mn enabled real time damage detection in composite. • Based on sensor position, correlation exists between TL signal and failure stress. • Introduced a new approach to damage characterization with TL profile analysis

  12. Statistical analysis on failure-to-open/close probability of motor-operated valve in sodium system

    International Nuclear Information System (INIS)

    Kurisaka, Kenichi

    1998-08-01

    The objective of this work is to develop basic data for examination on efficiency of preventive maintenance and actuation test from the standpoint of failure probability. This work consists of a statistical trend analysis of valve failure probability in a failure-to-open/close mode on time since installation and time since last open/close action, based on the field data of operating- and failure-experience. In this work, the terms both dependent and independent on time were considered in the failure probability. The linear aging model was modified and applied to the first term. In this model there are two terms with both failure rates in proportion to time since installation and to time since last open/close-demand. Because of sufficient statistical population, motor-operated valves (MOV's) in sodium system were selected to be analyzed from the CORDS database which contains operating data and failure data of components in the fast reactors and sodium test facilities. According to these data, the functional parameters were statistically estimated to quantify the valve failure probability in a failure-to-open/close mode, with consideration of uncertainty. (J.P.N.)

  13. Development of a subway operation incident delay model using accelerated failure time approaches.

    Science.gov (United States)

    Weng, Jinxian; Zheng, Yang; Yan, Xuedong; Meng, Qiang

    2014-12-01

    This study aims to develop a subway operational incident delay model using the parametric accelerated time failure (AFT) approach. Six parametric AFT models including the log-logistic, lognormal and Weibull models, with fixed and random parameters are built based on the Hong Kong subway operation incident data from 2005 to 2012, respectively. In addition, the Weibull model with gamma heterogeneity is also considered to compare the model performance. The goodness-of-fit test results show that the log-logistic AFT model with random parameters is most suitable for estimating the subway incident delay. First, the results show that a longer subway operation incident delay is highly correlated with the following factors: power cable failure, signal cable failure, turnout communication disruption and crashes involving a casualty. Vehicle failure makes the least impact on the increment of subway operation incident delay. According to these results, several possible measures, such as the use of short-distance and wireless communication technology (e.g., Wifi and Zigbee) are suggested to shorten the delay caused by subway operation incidents. Finally, the temporal transferability test results show that the developed log-logistic AFT model with random parameters is stable over time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Safety relevant failure mechanisms in the post-operational phase; Sicherheitstechnisch relevante Fehlermechanismen in der Nachbetriebsphase

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Gerhard; Stiller, Jan Christopher; Roemer, Sarah

    2017-03-15

    When the 13{sup th} amendment of the Atomic Energy Act came into force, eight Germ an nuclear power plant units had their power operating licences revoked and are now in the so-called post operation phase. Of the remaining nuclear power plants, one have by now also entered the post operation phase, with those left in operation bound for entering this phase sometime between now and the end of 2022. Therefore, failure mechanisms that are particularly relevant for post operation were to be identified and described in the frame of the present project. To do so, three major steps were taken: Firstly, recent national and international pertinent literature was evaluated to obtain indications of failure mechanisms in the post operation phase. It turned out that most of the national and international literature deals with the general procedure of the transition from power operation to decommissioning and dismantling. However, there were also some documents providing detailed indications of possible failure mechanisms in post operation. This includes e.g. the release of radioactive materials caused by the drop of containers, chemical impacts on systems important to safety in connection with decontamination work, and corrosion in connection with the storage of the core in the spent fuel pool, with the latter leading to the jamming of the fuel assemblies in the storage racks and a possible reduction of coolant circulation. In a second step, three safety analyses of pressurised water reactors prepared by the respective plant operators were evaluated to identify failure mechanisms based on systems engineering. The failure mechanisms that were found here include e.g. faults in the boric acid concentration of the reactor coolant, damage to the equipment airlock upon the unloading of Castor casks, leakages in connection with primary system decontamination, and the drop of packages holding radioactive residual materials or waste with subsequent mobilisation of radioactive aerosols

  15. Operating personnel error analysis during operation failures in the Kozloduj NPP

    International Nuclear Information System (INIS)

    Jonkova, A.

    1990-01-01

    The failures due to personnel errors are analyzed for 10 years period (1977-1986). Most of the results are presented in absolute values and are considered in dynamics. The indices for relative shares are compared by alternative analysis. One of the most important causes is the fluctuation of manpower. The failures distribution by months within the year and by hours of the day is given. The biggest number of failures occurred in the period April-October (without August - the month of the leaves), when the refueling and repair were taken place, and in January-February, due to heavy meteorological conditions and some fatigue and disconcentration because of multiple holidays. The failures during the day shifts had the greatest relative share - 42%, during the afternoon shifts - 26% and during the night shifts - 32% The most 'dangerous' time periods happened to be 11-12 h and 13-14 h (deteriorated attention after lunch), 20-22 h (physiological drop of the psychological activity), 0-3 h (the lowest level of physiological and psychological activity) and in the first and last hours of every shift. Three groups of causes are pointed out as the most frequent: improper actions connected with orders; improper independent actions; uncoordinated teamwork. The following measures are proposed for reducing the effect of the human factor: setting up the training centre; preliminary evaluation of the professional qualification of the operators; current dynamic control of their neuro-psychological fitness and occupational reliability. 1 fig, 2 tabs, 5 refs

  16. Analysis of arrhythmic events is useful to detect lead failure earlier in patients followed by remote monitoring.

    Science.gov (United States)

    Nishii, Nobuhiro; Miyoshi, Akihito; Kubo, Motoki; Miyamoto, Masakazu; Morimoto, Yoshimasa; Kawada, Satoshi; Nakagawa, Koji; Watanabe, Atsuyuki; Nakamura, Kazufumi; Morita, Hiroshi; Ito, Hiroshi

    2018-03-01

    Remote monitoring (RM) has been advocated as the new standard of care for patients with cardiovascular implantable electronic devices (CIEDs). RM has allowed the early detection of adverse clinical events, such as arrhythmia, lead failure, and battery depletion. However, lead failure was often identified only by arrhythmic events, but not impedance abnormalities. To compare the usefulness of arrhythmic events with conventional impedance abnormalities for identifying lead failure in CIED patients followed by RM. CIED patients in 12 hospitals have been followed by the RM center in Okayama University Hospital. All transmitted data have been analyzed and summarized. From April 2009 to March 2016, 1,873 patients have been followed by the RM center. During the mean follow-up period of 775 days, 42 lead failure events (atrial lead 22, right ventricular pacemaker lead 5, implantable cardioverter defibrillator [ICD] lead 15) were detected. The proportion of lead failures detected only by arrhythmic events, which were not detected by conventional impedance abnormalities, was significantly higher than that detected by impedance abnormalities (arrhythmic event 76.2%, 95% CI: 60.5-87.9%; impedance abnormalities 23.8%, 95% CI: 12.1-39.5%). Twenty-seven events (64.7%) were detected without any alert. Of 15 patients with ICD lead failure, none has experienced inappropriate therapy. RM can detect lead failure earlier, before clinical adverse events. However, CIEDs often diagnose lead failure as just arrhythmic events without any warning. Thus, to detect lead failure earlier, careful human analysis of arrhythmic events is useful. © 2017 Wiley Periodicals, Inc.

  17. Fuel failure in water reactors: Causes and mitigation. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2003-03-01

    The objective of this technical meeting (TM) was to review the present knowledge of the causes and mechanisms of fuel failure in water reactors during normal operational conditions. Emphasis has been given to analysis of failure causes and their mitigation by means of design as well as plant and core operation including strategies for operation with failed fuel. Some information on detection techniques (on-line monitoring and diagnostics, flux tilting, sipping techniques, etc) has also been presented. This TM presented also the progress on the above-mentioned subjects since the last meeting held in 1992 (Dimitrovgrad, Russian Federation). The topics covered in the papers were as follows: Experience feedback on fuel reliability (8 papers); Strategies to avoid or mitigate fuel failures (4 papers); Experimental studies on fuel failures and degradation mechanisms (4 papers); Modelling of fuel failure mechanisms (3 papers); Detection and monitoring during operation or outage (4 papers); Modelling and assessment of fuel failures (3 papers)

  18. Sensor failure detection in dynamical systems by Kalman filtering methodology

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1991-03-01

    Design of a sensor failure detection system by Kalman filtering methodology is described. The method models the process systems in state-space form, the information on each state being provided by relevant sensors present in the process system. Since the measured states are usually subject to noise, the estimation of the states optimally is an essential requirement. To this end the detection system comprises Kalman estimation filters, the number of which is equal to the number of states concerned. The estimated state of a particular signal in each filter is compared with the corresponding measured signal and difference beyond a predetermined bound is identified as failure, the sensor being identified/isolated as faulty. (author). 19 refs.; 8 figs.; 1 tab

  19. Analyses Of Techniques On Structural Fatigue Failure Detection ...

    African Journals Online (AJOL)

    Machines and structures are subjected to variable loading conditions where the stress cycle does not remain the same during the operation of the machine. Fatigue is undoubtedly one of the most serious of all causes of breakdowns of machines and structures which results in sudden failures. The use of the time domain ...

  20. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  1. Evaluation of the cool-down behaviour of ITER FW beryllium tiles for an early failure detection

    Directory of Open Access Journals (Sweden)

    Thomas Weber

    2016-12-01

    Full Text Available The design of the first wall in ITER foresees several hundred thousand beryllium tiles, which are bonded to the water-cooled CuCrZr supporting structure. Due to the nature of a Tokamak reactor this bonding is faced to thermal fatigue. Since the failure of a single tile might already have a major impact on the operability of ITER, comprehensive high heat flux tests are performed on prototypes prior to the acceptance of manufacturing procedures. For a deeper understanding of the temperature curves, which were and will be measured by IR devices of these first wall prototypes, thermo-mechanical FEM simulations shall demonstrate the possibilities of an early bonding failure detection. Hereby, the maximum temperatures for each cycle as well as the cool-down behaviour are the input data.

  2. A new method for detecting pressure tube failures in Indian PHWRs

    International Nuclear Information System (INIS)

    Sharma, V.K.; Gupta, V.K.

    2000-01-01

    For the annulus gas system (AGS) of the standardised Indian pressurised heavy water reactor, an elaborate pressure tube (PT) crack monitoring and detection system is envisaged to ensure safety through leak-before-break. The parameters that are monitored relate to the detection of D 2 O moisture leaking in from the primary heat transport (PHT) system through a cracked PT. Since a slow build-up of moisture in the AGS may also occur for reasons other than PT failure, it is desirable that a diverse measurement technique should be available. This paper suggests such a technique, based on the observation that a small reference concentration of fission gases is normally present in the annulus gas. This concentration would change sharply upon PT failure, when the heavy water from the leaking PHT system releases the dissolved fission gas content into the annulus. This paper presents a theoretical study of the parameters that influence the build-up of fission product noble gases in the AGS and shows that leakage rates as low as 10 g h -1 from a PT crack can be detected in a few tens of minutes by this method. This is expected to substantially increase the available time between the leak detection and the PT failure, thus serving as an important tool in meeting the leak-before-break criterion of a critical component in PHWRs. (orig.)

  3. Processing of Instantaneous Angular Speed Signal for Detection of a Diesel Engine Failure

    Directory of Open Access Journals (Sweden)

    Adam Charchalis

    2013-01-01

    Full Text Available Continuous monitoring of diesel engine performance under its operating is critical for the prediction of malfunction development and subsequently functional failure detection. Analysis of instantaneous angular speed (IAS of the crankshaft is considered as one of the nonintrusive and effective methods of the detection of combustion quality deterioration. In this paper results of experimental verification of fuel system's malfunction detecting, using optical encoder for IAS recording are presented. The implemented method relies on the comparison of measurement results, recorded under healthy and faulty conditions of the engine. Elaborated dynamic model of angular speed variations enables us to build templates of engine behavior. Recorded during experiment, values of cylinder pressure were taken for the approximation of pressure basic waveform. The main task of data processing is smoothing the raw angular speed signal. The noise is due to sensor mount vibrations, signal emitter machining, engine body vibrations, and crankshaft torsional vibrations. Smoothing of the measurement data was carried out by the implementation of the Savitzky-Golay filter. Measured signal after smoothing was compared with the model of IAS run.

  4. Interrelation of structure and operational states in cascading failure of overloading lines in power grids

    Science.gov (United States)

    Xue, Fei; Bompard, Ettore; Huang, Tao; Jiang, Lin; Lu, Shaofeng; Zhu, Huaiying

    2017-09-01

    As the modern power system is expected to develop to a more intelligent and efficient version, i.e. the smart grid, or to be the central backbone of energy internet for free energy interactions, security concerns related to cascading failures have been raised with consideration of catastrophic results. The researches of topological analysis based on complex networks have made great contributions in revealing structural vulnerabilities of power grids including cascading failure analysis. However, existing literature with inappropriate assumptions in modeling still cannot distinguish the effects between the structure and operational state to give meaningful guidance for system operation. This paper is to reveal the interrelation between network structure and operational states in cascading failure and give quantitative evaluation by integrating both perspectives. For structure analysis, cascading paths will be identified by extended betweenness and quantitatively described by cascading drop and cascading gradient. Furthermore, the operational state for cascading paths will be described by loading level. Then, the risk of cascading failure along a specific cascading path can be quantitatively evaluated considering these two factors. The maximum cascading gradient of all possible cascading paths can be used as an overall metric to evaluate the entire power grid for its features related to cascading failure. The proposed method is tested and verified on IEEE30-bus system and IEEE118-bus system, simulation evidences presented in this paper suggests that the proposed model can identify the structural causes for cascading failure and is promising to give meaningful guidance for the protection of system operation in the future.

  5. Dielectric Spectroscopic Detection of Early Failures in 3-D Integrated Circuits.

    Science.gov (United States)

    Obeng, Yaw; Okoro, C A; Ahn, Jung-Joon; You, Lin; Kopanski, Joseph J

    The commercial introduction of three dimensional integrated circuits (3D-ICs) has been hindered by reliability challenges, such as stress related failures, resistivity changes, and unexplained early failures. In this paper, we discuss a new RF-based metrology, based on dielectric spectroscopy, for detecting and characterizing electrically active defects in fully integrated 3D devices. These defects are traceable to the chemistry of the insolation dielectrics used in the through silicon via (TSV) construction. We show that these defects may be responsible for some of the unexplained early reliability failures observed in TSV enabled 3D devices.

  6. Performance and sensitivity analysis of the generalized likelihood ratio method for failure detection. M.S. Thesis

    Science.gov (United States)

    Bueno, R. A.

    1977-01-01

    Results of the generalized likelihood ratio (GLR) technique for the detection of failures in aircraft application are presented, and its relationship to the properties of the Kalman-Bucy filter is examined. Under the assumption that the system is perfectly modeled, the detectability and distinguishability of four failure types are investigated by means of analysis and simulations. Detection of failures is found satisfactory, but problems in identifying correctly the mode of a failure may arise. These issues are closely examined as well as the sensitivity of GLR to modeling errors. The advantages and disadvantages of this technique are discussed, and various modifications are suggested to reduce its limitations in performance and computational complexity.

  7. A formal language to describe a wide class of failure detection and signal validation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-01-01

    In the present article we make the first step towards the implementation of a user-friendly, object-oriented system devoted to failure detection and signal validation purposes. After overviewing different signal modelling, residual making and hypothesis testing procedures, a mathematical tool is suggested to describe a general failure detection problem. Three different levels of the abstraction are distinguished; direct examination, preliminary decision support mechanism and indirect examination. Possible scenarios are introduced depending both on the objective properties of the investigated signal and the particular requirements prescribed by the expert himself. Finally it is showed how to build up systematically a complete, general failure detection procedure. (author).

  8. Damage and failure detection of composites using optical fiber vibration sensor

    International Nuclear Information System (INIS)

    Yang, Y. C.; Han, K. S.

    2001-01-01

    An intensity-based optical fiber vibration sensor is applied to detect and evaluate damages and fiber failure of composites. The optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. Vibration characteristics of the optical fiber vibration sensor are investigated. Surface mounted optical fiber vibration sensor is used in tensile and indentation test. Experimental results show that the optical fiber sensor can detect damages and fiber failure of composites correctly

  9. Process pump operating problems and equipment failures, F-Canyon Reprocessing Facility, Savannah River Plant

    International Nuclear Information System (INIS)

    Durant, W.S.; Starks, J.B.; Galloway, W.D.

    1987-02-01

    A compilation of operating problems and equipment failures associated with the process pumps in the Savannah River Plant F-Canyon Fuel Reprocessing Facility is presented. These data have been collected over the 30-year operation of the facility. An analysis of the failure rates of the pumps is also presented. A brief description of the pumps and the data bank from which the information was sorted is also included

  10. Experience of automation failures in training: effects on trust, automation bias, complacency and performance.

    Science.gov (United States)

    Sauer, Juergen; Chavaillaz, Alain; Wastell, David

    2016-06-01

    This work examined the effects of operators' exposure to various types of automation failures in training. Forty-five participants were trained for 3.5 h on a simulated process control environment. During training, participants either experienced a fully reliable, automatic fault repair facility (i.e. faults detected and correctly diagnosed), a misdiagnosis-prone one (i.e. faults detected but not correctly diagnosed) or a miss-prone one (i.e. faults not detected). One week after training, participants were tested for 3 h, experiencing two types of automation failures (misdiagnosis, miss). The results showed that automation bias was very high when operators trained on miss-prone automation encountered a failure of the diagnostic system. Operator errors resulting from automation bias were much higher when automation misdiagnosed a fault than when it missed one. Differences in trust levels that were instilled by the different training experiences disappeared during the testing session. Practitioner Summary: The experience of automation failures during training has some consequences. A greater potential for operator errors may be expected when an automatic system failed to diagnose a fault than when it failed to detect one.

  11. Development of a system for automatic detection of pellet failures

    International Nuclear Information System (INIS)

    Lavagnino, C.E.

    1996-01-01

    Nowadays, the failure controls in UO 2 pellets for Atucha and Embalse reactors are performed visually. In this work it is presented the first stage of the development of a system that allows an automatic approach to the task. For this purpose, the problem has been subdivided in three jobs: choosing the illumination environment, finding the algorithm that detects failures with user-defined tolerance and engineering the mechanic system that supports the desired manipulations of the pellets. In this paper, the former two are developed. a) Finding the illumination conditions that allow subtracting the failure from the normal element surface, knowing, in first place, the cylindrical characteristics of it and, as a consequence, the differences in the light reflection direction and, in second place, the texture differences in relation to the rectification type of the pellet. b) Writing a fast and simple algorithm that allows the identification of the failure following the production specifications. Examples of the developed algorithm are shown. (author). 4 refs

  12. Failure detection system risk reduction assessment

    Science.gov (United States)

    Aguilar, Robert B. (Inventor); Huang, Zhaofeng (Inventor)

    2012-01-01

    A process includes determining a probability of a failure mode of a system being analyzed reaching a failure limit as a function of time to failure limit, determining a probability of a mitigation of the failure mode as a function of a time to failure limit, and quantifying a risk reduction based on the probability of the failure mode reaching the failure limit and the probability of the mitigation.

  13. Filter Design for Failure Detection and Isolation in the Presence of Modeling Erros and Disturbances

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Niemann, Hans Henrik

    1996-01-01

    The design problem of filters for robust Failure Detectionand Isolation, (FDI) is addressed in this paper. The failure detectionproblem will be considered with respect to both modeling errors anddisturbances. Both an approach based on failure detection observes aswell as an approach based...

  14. A quantitative impact analysis of sensor failures on human operator's decision making in nuclear power plants

    International Nuclear Information System (INIS)

    Seong, Poong Hyun

    2004-01-01

    In emergency or accident situations in nuclear power plants, human operators take important roles in generating appropriate control signals to mitigate accident situation. In human reliability analysis (HRA) in the framework of probabilistic safety assessment (PSA), the failure probabilities of such appropriate actions are estimated and used for the safety analysis of nuclear power plants. Even though understanding the status of the plant is basically the process of information seeking and processing by human operators, it seems that conventional HRA methods such as THERP, HCR, and ASEP does not pay a lot of attention to the possibilities of providing wrong information to human operators. In this paper, a quantitative impact analysis of providing wrong information to human operators due to instrument faults or sensor failures is performed. The quantitative impact analysis is performed based on a quantitative situation assessment model. By comparing the situation in which there are sensor failures and the situation in which there are not sensor failures, the impact of sensor failures can be evaluated quantitatively. It is concluded that the impact of sensor failures are quite significant at the initial stages, but the impact is gradually reduced as human operators make more and more observations. Even though the impact analysis is highly dependent on the situation assessment model, it is expected that the conclusions made based on other situation assessment models with be consistent with the conclusion made in this paper. (author)

  15. Feasibility of Detecting Natural Frequencies of Hydraulic Turbines While in Operation, Using Strain Gauges.

    Science.gov (United States)

    Valentín, David; Presas, Alexandre; Bossio, Matias; Egusquiza, Mònica; Egusquiza, Eduard; Valero, Carme

    2018-01-10

    Nowadays, hydropower plays an essential role in the energy market. Due to their fast response and regulation capacity, hydraulic turbines operate at off-design conditions with a high number of starts and stops. In this situation, dynamic loads and stresses over the structure are high, registering some failures over time, especially in the runner. Therefore, it is important to know the dynamic response of the runner while in operation, i.e., the natural frequencies, damping and mode shapes, in order to avoid resonance and fatigue problems. Detecting the natural frequencies of hydraulic turbine runners while in operation is challenging, because they are inaccessible structures strongly affected by their confinement in water. Strain gauges are used to measure the stresses of hydraulic turbine runners in operation during commissioning. However, in this paper, the feasibility of using them to detect the natural frequencies of hydraulic turbines runners while in operation is studied. For this purpose, a large Francis turbine runner (444 MW) was instrumented with several strain gauges at different positions. First, a complete experimental strain modal testing (SMT) of the runner in air was performed using the strain gauges and accelerometers. Then, the natural frequencies of the runner were estimated during operation by means of analyzing accurately transient events or rough operating conditions.

  16. Temperature noise analysis and sodium boiling detection in the fuel failure mockup

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Fry, D.N.; Leavell, W.H.; Mathis, M.V.; Saxe, R.F.

    1976-01-01

    Sodium temperature noise was measured at the exit of simulated, fast-reactor fuel subassemblies in the Fuel Failure Mockup (FFM) to determine the feasibility of using temperature noise monitors to detect flow blockages in fast reactors. Also, acoustic noise was measured to determine whether sodium boiling in the FFM could be detected acoustically and whether noncondensable gas entrained in the sodium coolant would affect the sensitivity of the acoustic noise detection system. Information from these studies would be applied to the design of safety systems for operating liquid-metal fast breeder reactors (LMFBRs). It was determined that the statistical properties of temperature noise are dependent on the shape of temperature profiles across the subassemblies, and that a blockage upstream of a thermocouple that increases the gradient of the profile near the blockage will also increase the temperature noise at the thermocouple. Amplitude probability analysis of temperature noise shows a skewed amplitude density function about the mean temperature that varies with the location of the thermocouple with respect to the blockage location. It was concluded that sodium boiling in the FFM could be detected acoustically. However, entrained noncondensable gas in the sodium coolant at void fractions greater than 0.4 percent attenuated the acoustic signals sufficiently that boiling was not detected. At a void fraction of 0.1 percent, boiling was indicated only by the two acoustic detectors closest to the boiling site

  17. Fault Detection and Location of IGBT Short-Circuit Failure in Modular Multilevel Converters

    Directory of Open Access Journals (Sweden)

    Bin Jiang

    2018-06-01

    Full Text Available A single fault detection and location for Modular Multilevel Converter (MMC is of great significance, as numbers of sub-modules (SMs in MMC are connected in series. In this paper, a novel fault detection and location method is proposed for MMC in terms of the Insulated Gate Bipolar Translator (IGBT short-circuit failure in SM. The characteristics of IGBT short-circuit failures are analyzed, based on which a Differential Comparison Low-Voltage Detection Method (DCLVDM is proposed to detect the short-circuit fault. Lastly, the faulty IGBT is located based on the capacitor voltage of the faulty SM by Continuous Wavelet Transform (CWT. Simulations have been done in the simulation software PSCAD/EMTDC and the results confirm the validity and reliability of the proposed method.

  18. Fuel element failure detection experiments, evaluation of the experiments at KNK II/1 (Intermediate Report)

    CERN Document Server

    Bruetsch, D

    1983-01-01

    In the frame of the fuel element failure detection experiments at KNK II with its first core the measurement devices of INTERATOM were taken into operation in August 1981 and were in operation almost continuously. Since the start-up until the end of the first KNK II core operation plugs with different fuel test areas were inserted in order to test the efficiency of the different measuring devices. The experimental results determined during this test phase and the gained experiences are described in this report and valuated. All three measuring techniques (Xenon adsorption line XAS, gas-chromatograph GC and precipitator PIT) could fulfil the expectations concerning their susceptibility. For XAS and GC the nuclide specific sensitivities as determined during the preliminary tests could be confirmed. For PIT the influences of different parameters on the signal yield could be determined. The sensitivity of the device could not be measured due to a missing reference measuring point.

  19. Comparison of different modelling approaches of drive train temperature for the purposes of wind turbine failure detection

    Science.gov (United States)

    Tautz-Weinert, J.; Watson, S. J.

    2016-09-01

    Effective condition monitoring techniques for wind turbines are needed to improve maintenance processes and reduce operational costs. Normal behaviour modelling of temperatures with information from other sensors can help to detect wear processes in drive trains. In a case study, modelling of bearing and generator temperatures is investigated with operational data from the SCADA systems of more than 100 turbines. The focus is here on automated training and testing on a farm level to enable an on-line system, which will detect failures without human interpretation. Modelling based on linear combinations, artificial neural networks, adaptive neuro-fuzzy inference systems, support vector machines and Gaussian process regression is compared. The selection of suitable modelling inputs is discussed with cross-correlation analyses and a sensitivity study, which reveals that the investigated modelling techniques react in different ways to an increased number of inputs. The case study highlights advantages of modelling with linear combinations and artificial neural networks in a feedforward configuration.

  20. Detecting failure events in buildings: a numerical and experimental analysis

    OpenAIRE

    Heckman, V. M.; Kohler, M. D.; Heaton, T. H.

    2010-01-01

    A numerical method is used to investigate an approach for detecting the brittle fracture of welds associated with beam -column connections in instrumented buildings in real time through the use of time-reversed Green’s functions and wave propagation reciprocity. The approach makes use of a prerecorded catalog of Green’s functions for an instrumented building to detect failure events in the building during a later seismic event by screening continuous data for the presence of wavef...

  1. Decrease the Number of Glovebox Glove Breaches and Failures

    Energy Technology Data Exchange (ETDEWEB)

    Hurtle, Jackie C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2013-12-24

    Los Alamos National Laboratory (LANL) is committed to the protection of the workers, public, and environment while performing work and uses gloveboxes as engineered controls to protect workers from exposure to hazardous materials while performing plutonium operations. Glovebox gloves are a weak link in the engineered controls and are a major cause of radiation contamination events which can result in potential worker exposure and localized contamination making operational areas off-limits and putting programmatic work on hold. Each day of lost opportunity at Technical Area (TA) 55, Plutonium Facility (PF) 4 is estimated at $1.36 million. Between July 2011 and June 2013, TA-55-PF-4 had 65 glovebox glove breaches and failures with an average of 2.7 per month. The glovebox work follows the five step safety process promoted at LANL with a decision diamond interjected for whether or not a glove breach or failure event occurred in the course of performing glovebox work. In the event that no glove breach or failure is detected, there is an additional decision for whether or not contamination is detected. In the event that contamination is detected, the possibility for a glove breach or failure event is revisited.

  2. Evaluating the operational risks of biomedical waste using failure mode and effects analysis.

    Science.gov (United States)

    Chen, Ying-Chu; Tsai, Pei-Yi

    2017-06-01

    The potential problems and risks of biomedical waste generation have become increasingly apparent in recent years. This study applied a failure mode and effects analysis to evaluate the operational problems and risks of biomedical waste. The microbiological contamination of biomedical waste seldom receives the attention of researchers. In this study, the biomedical waste lifecycle was divided into seven processes: Production, classification, packaging, sterilisation, weighing, storage, and transportation. Twenty main failure modes were identified in these phases and risks were assessed based on their risk priority numbers. The failure modes in the production phase accounted for the highest proportion of the risk priority number score (27.7%). In the packaging phase, the failure mode 'sharp articles not placed in solid containers' had the highest risk priority number score, mainly owing to its high severity rating. The sterilisation process is the main difference in the treatment of infectious and non-infectious biomedical waste. The failure modes in the sterilisation phase were mainly owing to human factors (mostly related to operators). This study increases the understanding of the potential problems and risks associated with biomedical waste, thereby increasing awareness of how to improve the management of biomedical waste to better protect workers, the public, and the environment.

  3. Comparison of Failure Analysis and Operating Experiences of Digital Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chan; Shin, Tae Young [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2014-08-15

    This study focuses on digital control systems that have the same functions but different designs. Some differences and common points between these two digital control systems are analyzed in terms of vulnerabilities in plant operation. In addition, this study confirms why unexpected outcomes can occur through a comparison of the system failure experiences with the analytic results of FMEA and FTA. This evaluation demonstrates that the digital system may have vulnerable components whose single failures can cause plant transients even if the system has a redundant structure according to its system design.

  4. System of the sensor failure detection and isolation system using Kalman filter

    International Nuclear Information System (INIS)

    Assumpcao Filho, E.O.; Nakata, H.

    1991-01-01

    The present work work summarizes the development of the sensor failure detection and isolation system (FDIS) suitable to be implemented in nuclear plant control systems. The methodology is based on the extended Kalman filter applied to a PWR pressurizer simplified model. The simulation of the most representative failure types showed the great reliability and fast response capability of the FDIS developed allowing the sizable savings in computational and economic expenditures. (author)

  5. Analytical Study of different types Of network failure detection and possible remedies

    Science.gov (United States)

    Saxena, Shikha; Chandra, Somnath

    2012-07-01

    Faults in a network have various causes,such as the failure of one or more routers, fiber-cuts, failure of physical elements at the optical layer, or extraneous causes like power outages. These faults are usually detected as failures of a set of dependent logical entities and the links affected by the failed components. A reliable control plane plays a crucial role in creating high-level services in the next-generation transport network based on the Generalized Multiprotocol Label Switching (GMPLS) or Automatically Switched Optical Networks (ASON) model. In this paper, approaches to control-plane survivability, based on protection and restoration mechanisms, are examined. Procedures for the control plane state recovery are also discussed, including link and node failure recovery and the concepts of monitoring paths (MPs) and monitoring cycles (MCs) for unique localization of shared risk linked group (SRLG) failures in all-optical networks. An SRLG failure is a failure of multiple links due to a failure of a common resource. MCs (MPs) start and end at same (distinct) monitoring location(s). They are constructed such that any SRLG failure results in the failure of a unique combination of paths and cycles. We derive necessary and sufficient conditions on the set of MCs and MPs needed for localizing an SRLG failure in an arbitrary graph. Procedure of Protection and Restoration of the SRLG failure by backup re-provisioning algorithm have also been discussed.

  6. Skin-Spar Failure Detection of a Composite Winglet Using FBG Sensors

    Directory of Open Access Journals (Sweden)

    Ciminello Monica

    2017-09-01

    Full Text Available Winglets are introduced into modern aircraft to reduce wing aerodynamic drag and to consequently optimize the fuel burn per mission. In order to be aerodynamically effective, these devices are installed at the wing tip section; this wing region is generally characterized by relevant oscillations induced by flights maneuvers and gust. The present work is focused on the validation of a continuous monitoring system based on fiber Bragg grating sensors and frequency domain analysis to detect physical condition of a skin-spar bonding failure in a composite winglet for in-service purposes. Optical fibers are used as deformation sensors. Short Time Fast Fourier Transform (STFT analysis is applied to analyze the occurrence of structural response deviations on the base of strain data. Obtained results showed high accuracy in estimating static and dynamic deformations and great potentials in detecting structural failure occurrences.

  7. Practical application of failure criteria in determining safe mud weight windows in drilling operations

    Directory of Open Access Journals (Sweden)

    R. Gholami

    2014-02-01

    Full Text Available Wellbore instability is reported frequently as one of the most significant incidents during drilling operations. Analysis of wellbore instability includes estimation of formation mechanical properties and the state of in situ stresses. In this analysis, the only controllable parameter during drilling operation is the mud weight. If the mud weight is larger than anticipated, the mud will invade into the formation, causing tensile failure of the formation. On the other hand, a lower mud weight can result in shear failures of rock, which is known as borehole breakouts. To predict the potential for failures around the wellbore during drilling, one should use a failure criterion to compare the rock strength against induced tangential stresses around the wellbore at a given mud pressure. The Mohr–Coulomb failure criterion is one of the commonly accepted criteria for estimation of rock strength at a given state of stress. However, the use of other criteria has been debated in the literature. In this paper, Mohr–Coulomb, Hoek–Brown and Mogi–Coulomb failure criteria were used to estimate the potential rock failure around a wellbore located in an onshore field of Iran. The log based analysis was used to estimate rock mechanical properties of formations and state of stresses. The results indicated that amongst different failure criteria, the Mohr–Coulomb criterion underestimates the highest mud pressure required to avoid breakouts around the wellbore. It also predicts a lower fracture gradient pressure. In addition, it was found that the results obtained from Mogi–Coulomb criterion yield a better comparison with breakouts observed from the caliper logs than that of Hoek–Brown criterion. It was concluded that the Mogi–Coulomb criterion is a better failure criterion as it considers the effect of the intermediate principal stress component in the failure analysis.

  8. Real-time sensor failure detection by dynamic modelling of a PWR plant

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.

    1992-06-01

    Signal validation and sensor failure detection is an important problem in real-time nuclear power plant (NPP) surveillance. Although conventional sensor redundancy, in a way, is a solution, identification of faulty sensor is necessary for further preventive actions to be taken. A comprehensive solution for the system so that any sensory reading is verified by its model based estimated counterpart, in real-time. Such a realization is accomplished by means of dynamic system's states estimation methodology using Kalman filter modelling technique. The method is investigated by means of real-time data of the steam generator of Borssele nuclear power plant and the method has proved to be satisfactory for real-time sensor failure detection as well as model validation verification. (author). 5 refs.; 6 figs.; 1 tab

  9. Failure rate modeling using fault tree analysis and Bayesian network: DEMO pulsed operation turbine study case

    International Nuclear Information System (INIS)

    Dongiovanni, Danilo Nicola; Iesmantas, Tomas

    2016-01-01

    Highlights: • RAMI (Reliability, Availability, Maintainability and Inspectability) assessment of secondary heat transfer loop for a DEMO nuclear fusion plant. • Definition of a fault tree for a nuclear steam turbine operated in pulsed mode. • Turbine failure rate models update by mean of a Bayesian network reflecting the fault tree analysis in the considered scenario. • Sensitivity analysis on system availability performance. - Abstract: Availability will play an important role in the Demonstration Power Plant (DEMO) success from an economic and safety perspective. Availability performance is commonly assessed by Reliability Availability Maintainability Inspectability (RAMI) analysis, strongly relying on the accurate definition of system components failure modes (FM) and failure rates (FR). Little component experience is available in fusion application, therefore requiring the adaptation of literature FR to fusion plant operating conditions, which may differ in several aspects. As a possible solution to this problem, a new methodology to extrapolate/estimate components failure rate under different operating conditions is presented. The DEMO Balance of Plant nuclear steam turbine component operated in pulse mode is considered as study case. The methodology moves from the definition of a fault tree taking into account failure modes possibly enhanced by pulsed operation. The fault tree is then translated into a Bayesian network. A statistical model for the turbine system failure rate in terms of subcomponents’ FR is hence obtained, allowing for sensitivity analyses on the structured mixture of literature and unknown FR data for which plausible value intervals are investigated to assess their impact on the whole turbine system FR. Finally, the impact of resulting turbine system FR on plant availability is assessed exploiting a Reliability Block Diagram (RBD) model for a typical secondary cooling system implementing a Rankine cycle. Mean inherent availability

  10. Radiographic failure and rates of re-operation after acromioclavicular joint reconstruction: a comparison of surgical techniques.

    Science.gov (United States)

    Spencer, H T; Hsu, L; Sodl, J; Arianjam, A; Yian, E H

    2016-04-01

    To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. ©2016 The British Editorial

  11. Failure rate modeling using fault tree analysis and Bayesian network: DEMO pulsed operation turbine study case

    Energy Technology Data Exchange (ETDEWEB)

    Dongiovanni, Danilo Nicola, E-mail: danilo.dongiovanni@enea.it [ENEA, Nuclear Fusion and Safety Technologies Department, via Enrico Fermi 45, Frascati 00040 (Italy); Iesmantas, Tomas [LEI, Breslaujos str. 3 Kaunas (Lithuania)

    2016-11-01

    Highlights: • RAMI (Reliability, Availability, Maintainability and Inspectability) assessment of secondary heat transfer loop for a DEMO nuclear fusion plant. • Definition of a fault tree for a nuclear steam turbine operated in pulsed mode. • Turbine failure rate models update by mean of a Bayesian network reflecting the fault tree analysis in the considered scenario. • Sensitivity analysis on system availability performance. - Abstract: Availability will play an important role in the Demonstration Power Plant (DEMO) success from an economic and safety perspective. Availability performance is commonly assessed by Reliability Availability Maintainability Inspectability (RAMI) analysis, strongly relying on the accurate definition of system components failure modes (FM) and failure rates (FR). Little component experience is available in fusion application, therefore requiring the adaptation of literature FR to fusion plant operating conditions, which may differ in several aspects. As a possible solution to this problem, a new methodology to extrapolate/estimate components failure rate under different operating conditions is presented. The DEMO Balance of Plant nuclear steam turbine component operated in pulse mode is considered as study case. The methodology moves from the definition of a fault tree taking into account failure modes possibly enhanced by pulsed operation. The fault tree is then translated into a Bayesian network. A statistical model for the turbine system failure rate in terms of subcomponents’ FR is hence obtained, allowing for sensitivity analyses on the structured mixture of literature and unknown FR data for which plausible value intervals are investigated to assess their impact on the whole turbine system FR. Finally, the impact of resulting turbine system FR on plant availability is assessed exploiting a Reliability Block Diagram (RBD) model for a typical secondary cooling system implementing a Rankine cycle. Mean inherent availability

  12. Failure analysis of re-bars during bending operations

    Directory of Open Access Journals (Sweden)

    Souvik Das

    2014-10-01

    Full Text Available Thermo-mechanical treated (TMT rebar is suitable material for reinforcing concrete structures on accounts of similarity in thermal expansion, ability to bond well with concrete and, above all the ability to shoulder most of the tensile stress acting on the structure and also steel manufacturing industry has successfully developed a corrosion-resistant variety of rebar for the construction industry. As the TMT is the finish product thus proper control of rolling parameters and water box is needed to achieve adequate property. Water box plays an important role for achieving the final structure and property of the rebars. Water box is responsible for outer rim formation and which helps to achieve the yield strength of the material. The present paper highlights failure investigation of a failed rebar during bending operations. From fractography and microstructural analysis it is confirmed that the rebar sample failed in brittle manner due to through harden martensitic structure and which indicates that there is some anomaly in water box resulting in these premature failures.

  13. 42 CFR 433.113 - Reduction of FFP for failure to operate a system and obtain initial approval.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Reduction of FFP for failure to operate a system... ADMINISTRATION Mechanized Claims Processing and Information Retrieval Systems § 433.113 Reduction of FFP for failure to operate a system and obtain initial approval. (a) Except as waived under § 433.130 or 433.131...

  14. Failure Analysis of Network Based Accessible Pedestrian Signals in Closed-Loop Operation

    Science.gov (United States)

    2011-03-01

    The potential failure modes of a network based accessible pedestrian system were analyzed to determine the limitations and benefits of closed-loop operation. The vulnerabilities of the system are accessed using the industry standard process known as ...

  15. Program for generating tests for the detection of failures in combinatorial logic systems

    International Nuclear Information System (INIS)

    Mansour, Mounir

    1972-01-01

    A method for generating test sequences for detecting failures in combinatorial logic systems, is described. It relies on: the splitting of these systems into elements of NOR and NAND circuits, the propagation of the failure state from the input to the output. Test sequences generation is achieved in two steps: a first one called chaining during which are investigated the propagation paths of an input state able to show off failures, a second one called consistency during which the global state of the circuit related to this input configuration is held to the wanted state so that the propagation takes place. (author) [fr

  16. Statistical analysis of events related to emergency diesel generators failures in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Kančev, Duško, E-mail: dusko.kancev@ec.europa.eu [European Commission, DG-JRC, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Duchac, Alexander; Zerger, Benoit [European Commission, DG-JRC, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Maqua, Michael [Gesellschaft für Anlagen-und-Reaktorsicherheit (GRS) mbH, Schwetnergasse 1, 50667 Köln (Germany); Wattrelos, Didier [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), BP 17 - 92262 Fontenay-aux-Roses Cedex (France)

    2014-07-01

    Highlights: • Analysis of operating experience related to emergency diesel generators events at NPPs. • Four abundant operating experience databases screened. • Delineating important insights and conclusions based on the operating experience. - Abstract: This paper is aimed at studying the operating experience related to emergency diesel generators (EDGs) events at nuclear power plants collected from the past 20 years. Events related to EDGs failures and/or unavailability as well as all the supporting equipment are in the focus of the analysis. The selected operating experience was analyzed in detail in order to identify the type of failures, attributes that contributed to the failure, failure modes potential or real, discuss risk relevance, summarize important lessons learned, and provide recommendations. The study in this particular paper is tightly related to the performing of statistical analysis of the operating experience. For the purpose of this study EDG failure is defined as EDG failure to function on demand (i.e. fail to start, fail to run) or during testing, or an unavailability of an EDG, except of unavailability due to regular maintenance. The Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases as well as the operating experience contained in the IAEA/NEA International Reporting System for Operating Experience and the U.S. Licensee Event Reports were screened. The screening methodology applied for each of the four different databases is presented. Further on, analysis aimed at delineating the causes, root causes, contributing factors and consequences are performed. A statistical analysis was performed related to the chronology of events, types of failures, the operational circumstances of detection of the failure and the affected components/subsystems. The conclusions and results of the statistical analysis are discussed. The main findings concerning the testing

  17. Statistical analysis of events related to emergency diesel generators failures in the nuclear industry

    International Nuclear Information System (INIS)

    Kančev, Duško; Duchac, Alexander; Zerger, Benoit; Maqua, Michael; Wattrelos, Didier

    2014-01-01

    Highlights: • Analysis of operating experience related to emergency diesel generators events at NPPs. • Four abundant operating experience databases screened. • Delineating important insights and conclusions based on the operating experience. - Abstract: This paper is aimed at studying the operating experience related to emergency diesel generators (EDGs) events at nuclear power plants collected from the past 20 years. Events related to EDGs failures and/or unavailability as well as all the supporting equipment are in the focus of the analysis. The selected operating experience was analyzed in detail in order to identify the type of failures, attributes that contributed to the failure, failure modes potential or real, discuss risk relevance, summarize important lessons learned, and provide recommendations. The study in this particular paper is tightly related to the performing of statistical analysis of the operating experience. For the purpose of this study EDG failure is defined as EDG failure to function on demand (i.e. fail to start, fail to run) or during testing, or an unavailability of an EDG, except of unavailability due to regular maintenance. The Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases as well as the operating experience contained in the IAEA/NEA International Reporting System for Operating Experience and the U.S. Licensee Event Reports were screened. The screening methodology applied for each of the four different databases is presented. Further on, analysis aimed at delineating the causes, root causes, contributing factors and consequences are performed. A statistical analysis was performed related to the chronology of events, types of failures, the operational circumstances of detection of the failure and the affected components/subsystems. The conclusions and results of the statistical analysis are discussed. The main findings concerning the testing

  18. [Early detection, prevention and management of renal failure in liver transplantation].

    Science.gov (United States)

    Castells, Lluís; Baliellas, Carme; Bilbao, Itxarone; Cantarell, Carme; Cruzado, Josep Maria; Esforzado, Núria; García-Valdecasas, Juan Carlos; Lladó, Laura; Rimola, Antoni; Serón, Daniel; Oppenheimer, Federico

    2014-10-01

    Renal failure is a frequent complication in liver transplant recipients and is associated with increased morbidity and mortality. A variety of risk factors for the development of renal failure in the pre- and post-transplantation periods have been described, as well as at the time of surgery. To reduce the negative impact of renal failure in this population, an active approach is required for the identification of those patients with risk factors, the implementation of preventive strategies, and the early detection of progressive deterioration of renal function. Based on published evidence and on clinical experience, this document presents a series of recommendations on monitoring RF in LT recipients, as well as on the prevention and management of acute and chronic renal failure after LT and referral of these patients to the nephrologist. In addition, this document also provides an update of the various immunosuppressive regimens tested in this population for the prevention and control of post-transplantation deterioration of renal function. Copyright © 2013 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.

  19. Method of detecting a fuel element failure

    International Nuclear Information System (INIS)

    Cohen, P.

    1975-01-01

    A method is described for detecting a fuel element failure in a liquid-sodium-cooled fast breeder reactor consisting of equilibrating a sample of the coolant with a molten salt consisting of a mixture of barium iodide and strontium iodide (or other iodides) whereby a large fraction of any radioactive iodine present in the liquid sodium coolant exchanges with the iodine present in the salt; separating the molten salt and sodium; if necessary, equilibrating the molten salt with nonradioactive sodium and separating the molten salt and sodium; and monitoring the molten salt for the presence of iodine, the presence of iodine indicating that the cladding of a fuel element has failed. (U.S.)

  20. Development of evaluation method of fuel failure fraction during the High Temperature Engineering Test Reactor operation

    Energy Technology Data Exchange (ETDEWEB)

    Sawa, Kazuhiro; Yoshimuta, Shigeharu; Tobita, Tsutomu; Sato, Masashi [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    1997-05-01

    The High Temperature Engineering Test Reactor (HTTR) uses coated particles as fuel. During normal operation, short-lived noble gases are mainly released by diffusion from fuel particles with defects in their coating layers (i.e., failed particle). Since noble gases do not plate out on the inner surfaces of primary cooling system, their activities in primary coolant reflect fuel failure fraction in the core. An evaluation method was developed to predict failure fraction of coated fuel particles during normal operation of the HTTR. The method predicts core-average and hot plenum regionwise failure fractions based on the fractional releases, (R/B)s, of noble gases. The (R/B)s are calculated by fission gas concentration measurements in the primary cooling system of the HTTR. Recent fabrication data show that through-coatings failure fraction is extremely low. Then, fractional release from matrix contamination uranium, which is background for accurate evaluation of the fuel failure fraction, should be precisely predicted. This report describes an evaluation method of fuel failure fraction from measurements in the HTTR together with a fission gas release model from fuel compact containing failed particles and matrix contamination uranium. (author)

  1. Fuel failure detection and location in LMFBRs

    International Nuclear Information System (INIS)

    Jacobi, S.

    1982-06-01

    The Specialists' Meeting on 'Fuel Failure Detection and Location in LMFBRs' was held at the Kernforschungszentrum Karlsruhe, Federal Republic of Germany, on 11-14 May 1981. The meeting was sponsored by the International Atomic Energy Agency (IAEA) on the recommendation of the International Working Group on Fast Reactors (IWGFR).The purpose of the meeting was to review and discuss methods and experience in the detection and location of failed fuel elements and to recommend future development. The technical sessions were divided into five topical sessions as follows: 1. Reactor Intrumentation, 2. Experience Gained from LMFBRs, 3. In-pile Experiments, 4. Models and Codes, 5. Future Programs. During the meeting papers were presented by the participants on behalf of their countries or organizations. Each presentation was followed by an open discussion in the subject covered by the presentation. After the formal sessions were completed, a final discussion session was held and general conclusions and recommendationswere reached. Session summaries, general conclusions and recommendations, the agenda of the meeting and the list of participants are given. (orig./RW)

  2. Optimal processor for malfunction detection in operating nuclear reactor

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1990-01-01

    An optimal processor for diagnosing operational transients in a nuclear reactor is described. Basic design of the processor involves real-time processing of noise signal obtained from a particular in core sensor and the optimality is based on minimum alarm failure in contrast to minimum false alarm criterion from the safe and reliable plant operation viewpoint

  3. Pilot program to identify valve failures which impact the safety and operation of light water nuclear power plants

    International Nuclear Information System (INIS)

    Tsacoyeanes, J.C.; Raju, P.P.

    1980-04-01

    The pilot program described has been initiated under the Department of Energy Light Water Reactor Safety Research and Development Program and has the following specific objectives: to identify the principal types and causes of failures in valves, valve operators and their controls and associated hardware, which lead to, or could lead to plant trip; and to suggest possible remedies for the prevention of these failures and recommend future research and development programs which could lead to minimizing these valve failures or mitigating their effect on plant operation. The data surveyed cover incidents reported over the six-year period, beginning 1973 through the end of 1978. Three sources of information on valve failures have been consulted: failure data centers, participating organizations in the nuclear power industry, and technical documents

  4. A Novel Technique for Rotor Bar Failure Detection in Single-Cage Induction Motor Using FEM and MATLAB/SIMULINK

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Taher

    2011-01-01

    Full Text Available In this article, a new fault detection technique is proposed for squirrel cage induction motor (SCIM based on detection of rotor bar failure. This type of fault detection is commonly carried out, while motor continues to work at a steady-state regime. Recently, several methods have been presented for rotor bar failure detection based on evaluation of the start-up transient current. The proposed method here is capable of fault detection immediately after bar breakage, where a three-phase SCIM is modelled in finite element method (FEM using Maxwell2D software. Broken rotor bars are then modelled by the corresponding outer rotor impedance obtained by GA, thereby presenting an analogue model extracted from FEM to be simulated in a flexible environment such as MATLAB/SIMULINK. To improve the failure recognition, the stator current signal was analysed using discrete wavelet transform (DWT.

  5. Numerical study of damage evolution and failure in an electromagnetic corner fill operation

    International Nuclear Information System (INIS)

    Imbert, J.M.; Winkler, S.L.; Worswick, M.J.; Oliveira, D.A.; Golovashchenko, S.

    2004-01-01

    A numerical study of an electromagnetic corner fill operation using AA5754 aluminum alloy sheet was performed. Conical parts with side angles of 40 and 45 deg. (included angles of 100 and 90 deg.) were modeled. The numerical calculations were performed with an explicit dynamic finite element structural code, using an analytical electromagnetic pressure distribution. Damage evolution was predicted using a damage subroutine based on the Gurson-Tvergaard-Needleman constitutive model. Experiments were performed to validate the numerical results. Damage measurements were made using optical microscopy to determine the actual damage produced by the forming operations. Predicted final shape, failure and damage levels are presented and compared with experimental results. The numerical models were able to accurately predict damage trends. Failure was predicted in general agreement with the experiments

  6. Two loose screws: near-miss fall of a morbidly obese patient after an operating room table failure.

    Science.gov (United States)

    McAllister, Russell K; Booth, Robert T; Bittenbinder, Timothy M

    2016-09-01

    Operating room surgical table failure is a rare event but can lead to a dangerous situation when it does occur. The dangers can be compounded in the presence of obesity, especially in the anesthetized or sedated patient. We present a case of a near-miss fall of a morbidly obese patient while turning the patient in preparation to transfer from the operating room table to the hospital bed when 2 fractured bolts in the tilt cylinder mechanism led to an operating room table failure. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Remaining useful life estimation for deteriorating systems with time-varying operational conditions and condition-specific failure zones

    Directory of Open Access Journals (Sweden)

    Li Qi

    2016-06-01

    Full Text Available Dynamic time-varying operational conditions pose great challenge to the estimation of system remaining useful life (RUL for the deteriorating systems. This paper presents a method based on probabilistic and stochastic approaches to estimate system RUL for periodically monitored degradation processes with dynamic time-varying operational conditions and condition-specific failure zones. The method assumes that the degradation rate is influenced by specific operational condition and moreover, the transition between different operational conditions plays the most important role in affecting the degradation process. These operational conditions are assumed to evolve as a discrete-time Markov chain (DTMC. The failure thresholds are also determined by specific operational conditions and described as different failure zones. The 2008 PHM Conference Challenge Data is utilized to illustrate our method, which contains mass sensory signals related to the degradation process of a commercial turbofan engine. The RUL estimation method using the sensor measurements of a single sensor was first developed, and then multiple vital sensors were selected through a particular optimization procedure in order to increase the prediction accuracy. The effectiveness and advantages of the proposed method are presented in a comparison with existing methods for the same dataset.

  8. Recent Operating Experience involving Power Electronics Failure in Korea Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Jaedo

    2015-01-01

    Recently, modern power electronics devices for electrical component were steadily increased in electrical systems which used for main power control and protection. To upgrade the system reliability we recommended the redundancy for electrical equipment trip system. The past several years, Korean Nuclear power plants have changed the electrical control and protection systems (Auto Voltage Regulator, Power Protection Relay) for main generator and main power protection relay systems. In this paper we deal with operating experience involving modern solid state power electronics failure in Korean nuclear power plants. One of the failures we will discuss the degraded phenomenon of power electronics device for CEDMCS(Control Element Drive Mechanism Control System). As the result of the failure we concerned about the modification for trip source of main generator excitation systems and others. We present an interesting issue for modern solid state devices (IGBT, Thyristors). (authors)

  9. On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing

    Energy Technology Data Exchange (ETDEWEB)

    Sappok, Alex [Filter Sensing Technologies; Ragaller, Paul [Filter Sensing Technologies; Herman, Andrew [CTS Corporation; Bromberg, L. [Massachusetts Institute of Technology (MIT); Prikhodko, Vitaly Y [ORNL; Parks, II, James E [ORNL; Storey, John Morse [ORNL

    2017-01-01

    The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.

  10. Failures of fine tubes of steam generators and the essential defects

    International Nuclear Information System (INIS)

    Kawano, Shinji; Ebisawa, Toru; Sato, Susumu.

    1976-01-01

    Light water reactors were sold to Japan as their economy and safety have been established, but the average availability of 11 reactors in Japan during 7 year operation is only 53%, and it is being proved that there are questions in the safety and economy. In this report, the failures of fine tubes of steam generators are discussed from the standpoint of the corrosion of materials. First, the functions and construction of the fine tubes of steam generators in PWRs are explained. The failures of the fine tubes of steam generators became frequent since the beginning of 1970s as large capacity nuclear power stations have started the operation. When the fine tubes are pierced with holes during operation and the radioactivity in primary coolant leaks into secondary coolant, it is detected with radioactivity monitors. In order to find out the broken tubes, eddy current flaw detectors are used, and the tubes on which flaws were detected we plugged by explosion welding. In these works, many manual operations are included, and the radiation exposure of workers and the difficulties in the operations are the problems. The cases of the tube failures in Japan and foreign countries, the causes and the countermeasures are described. Chemical corrosion, thermal stress cycle, shaving off due to eddy flow, and stress corrosion are the probable causes. The safety of steam generators is essentially in extremely poor state. The seriousness of the tube failures in steam generators is emphasized. (Kako, I.)

  11. Novel Detection Method for Consecutive DC Commutation Failure Based on Daubechies Wavelet with 2nd-Order Vanishing Moments

    Directory of Open Access Journals (Sweden)

    Tao Lin

    2018-01-01

    Full Text Available Accurate detection and effective control strategy of commutation failure (CF of high voltage direct current (HVDC are of great significance for keeping the safe and stable operations of the hybrid power grid. At first, a novel detection method for consecutive CF is proposed. Concretely, the 2nd and higher orders’ derivative values of direct current are summarized as the core to judge CF by analyzing the physical characteristics of the direct current waveform of the converter station in CF. Then, the Daubechies wavelet coefficient that can represent the 2nd and higher order derivative values of direct current is derived. Once the wavelet coefficients of the sampling points are detected to exceed the threshold, the occurrence of CF is confirmed. Furthermore, by instantly increasing advanced firing angle β in the inverter side, an additional emergency control strategy to prevent subsequent CF is proposed. Eventually, with simulations of the benchmark model, the effectiveness and superiorities of the proposed detection method and additional control strategy in accuracy and rapidity are verified.

  12. Evaluation of a Kalman filter based power pressurizer instrument failure detection system implemented on a nuclear power plant training simulator

    International Nuclear Information System (INIS)

    Seegmiller, D.S.

    1984-01-01

    The usefulness of a nuclear power plant training simulator for developing and testing modern estimation and control applications for nuclear power plants is demonstrated. A Kalman filter based instrument failure detection technique for a pressurized water reactor pressurizer is implemented on the Department of Energy N Reactor Training Simulator. This real-time failure detection method computes the first two moments (mean and variance) of each element of a normalized filter innovations vector. Failed pressurizer instrumentation can be detected by comparing these moments to the known statistical properties of the steady state, linear Kalman fitler innovations sequence. The capabilities of the detection system are evaluated using simulated plant transients and instrument failures

  13. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    International Nuclear Information System (INIS)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon

    2017-01-01

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery

  14. Optimally Robust Redundancy Relations for Failure Detection in Uncertain Systems,

    Science.gov (United States)

    1983-04-01

    particular applications. While the general methods provide the basis for what in principle should be a widely applicable failure detection methodology...modifications to this result which overcome them at no fundmental increase in complexity. 4.1 Scaling A critical problem with the criteria of the preceding...criterion which takes scaling into account L 2 s[ (45) As in (38), we can multiply the C. by positive scalars to take into account unequal weightings on

  15. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  16. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  17. Influence of some fabrication parameters and operating conditions on the PCI failure occurrence in LWR fuel rods

    International Nuclear Information System (INIS)

    Bouffioux, P.

    1980-01-01

    In recent LWR designs, the fuel rod failures are induced by a chemically assisted mechanical process, i.e. stress corrosion cracking. The analytical approach towards the analysis of PCI-SCC failures is mainly based on the predictions of the COMETHE code. The failure criteria rely on the concept of a stress threshold together with fission product availability. In the present paper, the use of the COMETHE code to minimize PCI induced clad failure occurrences is illustrated by parametric studies to define acceptable fuel specifications and reactor operating conditions (steady and transient). (author)

  18. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p < 0.05), intra- or peri-flap air collection > 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery.

  19. Using pattern analysis methods to do fast detection of manufacturing pattern failures

    Science.gov (United States)

    Zhao, Evan; Wang, Jessie; Sun, Mason; Wang, Jeff; Zhang, Yifan; Sweis, Jason; Lai, Ya-Chieh; Ding, Hua

    2016-03-01

    At the advanced technology node, logic design has become extremely complex and is getting more challenging as the pattern geometry size decreases. The small sizes of layout patterns are becoming very sensitive to process variations. Meanwhile, the high pressure of yield ramp is always there due to time-to-market competition. The company that achieves patterning maturity earlier than others will have a great advantage and a better chance to realize maximum profit margins. For debugging silicon failures, DFT diagnostics can identify which nets or cells caused the yield loss. But normally, a long time period is needed with many resources to identify which failures are due to one common layout pattern or structure. This paper will present a new yield diagnostic flow, based on preliminary EFA results, to show how pattern analysis can more efficiently detect pattern related systematic defects. Increased visibility on design pattern related failures also allows more precise yield loss estimation.

  20. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  1. NATO Symposium on Human Detection and Diagnosis of System Failures

    CERN Document Server

    Rouse, William

    1981-01-01

    This book includes all of the papers presented at the NATO Symposium on Human Detection and Diagnosis of System Failures held at Roskilde, Denmark on August 4-8, 1980. The Symposium was sponsored by the Scientific Affairs Division of NATO and the Rise National Laboratory of Denmark. The goal of the Symposium was to continue the tradition initiated by the NATO Symposium on Monitoring Behavior and Supervisory Control held in Berchtesgaden, F .R. Germany in 1976 and the NATO Symposium on Theory and Measurement of Mental Workload held in Mati, Greece in 1977. To this end, a group of 85 psychologists and engineers coming from industry, government, and academia convened to discuss, and to generate a "state-of-the-art" consensus of the problems and solutions associated with the human IS ability to cope with the increasing scale of consequences of failures within complex technical systems. The Introduction of this volume reviews their findings. The Symposium was organized to include brief formal presentations of pape...

  2. PSA methodology including new design, operational and safety factors, 'Level of recognition of phenomena with a presumed dominant influence upon operational safety' (failures of conventional as well as non-conventional passive components, dependent failures, influence of operator, fires and external threats, digital control, organizational factors)

    International Nuclear Information System (INIS)

    Jirsa, P.

    2001-10-01

    The document represents a specific type of discussion of existing methodologies for the creation and application of probabilistic safety assessment (PSA) in light of the EUR document summarizing requirements placed by Western European NPP operators on the future design of nuclear power plants. A partial goal of this discussion consists in mapping, from the PSA point of view, those selected design, operational and/or safety factors of future NPPs that may be entirely new or, at least, newly addressed. Therefore, the terms of reference for this stage were formulated as follows: Assess current level of knowledge and procedures in the analysis of factors and phenomena with a dominant influence upon operational safety of new generation reactors, especially in the following areas: (1) Phenomenology of failure types and mechanisms and reliability of conventional passive safety system components; (2) Phenomenology of failure types and mechanisms and reliability of non-conventional passive components of newly designed safety systems; (3) Phenomenology of types and mechanisms of dependent failures; (4) Human factor role in new generation reactors and its effect upon safety; (5) Fire safety and other external threats to new nuclear installations; (6) Reliability of the digital systems of the I and C system and their effect upon safety; and (7) Organizational factors in new nuclear installations. (P.A.)

  3. Link failure detection in a parallel computer

    Science.gov (United States)

    Archer, Charles J.; Blocksome, Michael A.; Megerian, Mark G.; Smith, Brian E.

    2010-11-09

    Methods, apparatus, and products are disclosed for link failure detection in a parallel computer including compute nodes connected in a rectangular mesh network, each pair of adjacent compute nodes in the rectangular mesh network connected together using a pair of links, that includes: assigning each compute node to either a first group or a second group such that adjacent compute nodes in the rectangular mesh network are assigned to different groups; sending, by each of the compute nodes assigned to the first group, a first test message to each adjacent compute node assigned to the second group; determining, by each of the compute nodes assigned to the second group, whether the first test message was received from each adjacent compute node assigned to the first group; and notifying a user, by each of the compute nodes assigned to the second group, whether the first test message was received.

  4. Modelling software failures of digital I and C in probabilistic safety analyses based on the TELEPERM registered XS operating experience

    International Nuclear Information System (INIS)

    Jockenhoevel-Barttfeld, Mariana; Taurines Andre; Baeckstroem, Ola; Holmberg, Jan-Erik; Porthin, Markus; Tyrvaeinen, Tero

    2015-01-01

    Digital instrumentation and control (I and C) systems appear as upgrades in existing nuclear power plants (NPPs) and in new plant designs. In order to assess the impact of digital system failures, quantifiable reliability models are needed along with data for digital systems that are compatible with existing probabilistic safety assessments (PSA). The paper focuses on the modelling of software failures of digital I and C systems in probabilistic assessments. An analysis of software faults, failures and effects is presented to derive relevant failure modes of system and application software for the PSA. The estimations of software failure probabilities are based on an analysis of the operating experience of TELEPERM registered XS (TXS). For the assessment of application software failures the analysis combines the use of the TXS operating experience at an application function level combined with conservative engineering judgments. Failure probabilities to actuate on demand and of spurious actuation of typical reactor protection application are estimated. Moreover, the paper gives guidelines for the modelling of software failures in the PSA. The strategy presented in this paper is generic and can be applied to different software platforms and their applications.

  5. Operational failure at the Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Szatmary, Z.

    2003-01-01

    NPP failures are ranked according to the International Nuclear Event Scale. To rank the failure first a presentation of the pressurized water plant is given, including fuel change, maintenance cleaning and decontamination process. The failure has been produced with fuel bars in the cleaning container. Consequences of the failure are small, negligible environmental pollution with radioactive material and significant financial outfall due to inactivity of block 2. Among the causes of the failure are design errors of the cleaning container, the pure chemical approach to cleaning, unknown risk factors for some of the cleaning staff, cleaning container has not been verified and approved by responsible authorities, the prevalence of economic and quantitative indicators of the plant on the detriment of safety. Organisational factors also contribute to the possibility of nuclear failures. Specialist training in Germany (where the container has been produced) is significantly reduced, while in Hungary the political tide has caused a permanent change in the higher echelons of the plant management, where nuclear specialists were not included. (Gy.M.)

  6. Design of a application of failure registration in equipment of radiotherapy treatments

    International Nuclear Information System (INIS)

    Martinez Ortega, J.; Rodriguez Cobo, C.; Pinto Monedero, M.; Rodriguez Romero, R.; Castro Tejero, P.; Sanchez Rubio, P.; Quintana Paz, A.

    2013-01-01

    It has developed an application that aims to provide a centralized database of service interventions, and can detect deficiencies at the time of response, percentages of operability or persistent failures in units. (Author)

  7. Similar failure rate in immediate post-operative weight bearing versus protected weight bearing following meniscal repair on peripheral, vertical meniscal tears.

    Science.gov (United States)

    Perkins, Bryan; Gronbeck, Kyle R; Yue, Ruixian Alexander; Tompkins, Marc A

    2017-08-16

    Post-operative weight bearing after meniscal repair is a point of debate among physicians. This study sought to evaluate whether patients adhering to an immediate WBAT rehabilitation programme have a higher failure rate compared to those adhering to a more traditional, protected, NWB status following meniscal repair. The null hypothesis was that there would be no difference in failure between the two groups. A retrospective review of meniscal repair patients greater than 5 years from surgery was performed for patients receiving meniscal repair treatment. Patients were categorized by post-surgical weight-bearing status, either NWB or WBAT, and then analysed for failure of repair. Failure was defined as re-operation on the torn meniscus. The study controlled for variables including age at surgery, sex, height, weight, and BMI, classification of tear type, acuity of the tear, repair location (medial or lateral), repair location within the meniscus, repair technique, and concomitant procedures. Re-operations were performed in 61 of 157 patients [38.9%]. There was no difference between weight-bearing groups for failure of meniscus repair (n.s.). The tears were acute vertical tears located in the posterior horn and body. For the 61 patients with re-operation, the average time to re-operation was 2.2 years with 10 [16%] > 5 years from surgery, 17 [28%] 2-5 years from surgery, and 34 [56%] bearing groups for rate of re-operation (n.s.). Weight bearing as tolerated after meniscal repair for peripheral, vertical tears does not result in a higher failure rate than traditional, non-weight bearing over a five-year follow-up period. The clinical relevance is that, based on these data, it may be appropriate to allow weight bearing as tolerated following meniscal repair of peripheral, vertical tears. Retrospective cohort study, Level III.

  8. Early Detection of Plant Equipment Failures: A Case Study in Just-in-Time Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-06-17

    The development and testing of a model-based fault detection system for electric motors is briefly presented. The fault detection system was developed using only motor nameplate information. The fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. Dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Multiresolution (or wavelet) signal-processing techniques are used in combination with more traditional methods to estimate fault features for use in winding insulation and motor mechanical and electromechanical failure detection.

  9. Early Detection of Plant Equipment Failures: A Case Study in Just-in-Time Maintenance

    International Nuclear Information System (INIS)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-01-01

    The development and testing of a model-based fault detection system for electric motors is briefly presented. The fault detection system was developed using only motor nameplate information. The fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. Dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Multiresolution (or wavelet) signal-processing techniques are used in combination with more traditional methods to estimate fault features for use in winding insulation and motor mechanical and electromechanical failure detection

  10. VALIDATION OF SPRING OPERATED PRESSURE RELIEF VALVE TIME TO FAILURE AND THE IMPORTANCE OF STATISTICALLY SUPPORTED MAINTENANCE INTERVALS

    Energy Technology Data Exchange (ETDEWEB)

    Gross, R; Stephen Harris, S

    2009-02-18

    The Savannah River Site operates a Relief Valve Repair Shop certified by the National Board of Pressure Vessel Inspectors to NB-23, The National Board Inspection Code. Local maintenance forces perform inspection, testing, and repair of approximately 1200 spring-operated relief valves (SORV) each year as the valves are cycled in from the field. The Site now has over 7000 certified test records in the Computerized Maintenance Management System (CMMS); a summary of that data is presented in this paper. In previous papers, several statistical techniques were used to investigate failure on demand and failure rates including a quantal response method for predicting the failure probability as a function of time in service. The non-conservative failure mode for SORV is commonly termed 'stuck shut'; industry defined as the valve opening at greater than or equal to 1.5 times the cold set pressure. Actual time to failure is typically not known, only that failure occurred some time since the last proof test (censored data). This paper attempts to validate the assumptions underlying the statistical lifetime prediction results using Monte Carlo simulation. It employs an aging model for lift pressure as a function of set pressure, valve manufacturer, and a time-related aging effect. This paper attempts to answer two questions: (1) what is the predicted failure rate over the chosen maintenance/ inspection interval; and do we understand aging sufficient enough to estimate risk when basing proof test intervals on proof test results?

  11. Premature failure of dissimilar metal weld joint at intermediate temperature superheater tube

    Directory of Open Access Journals (Sweden)

    Mohammed Al Hajri

    2015-04-01

    Full Text Available Dissimilar metal weld (DMW joint between alloyed steel (AS and stainless steel (SS failed at one of intermediate temperature superheater (ITSH tube in steam/power generation plant boiler. The premature failure was detected after a relatively short time of operation (8 years where the crack propagated circumferentially from AS side through the ITSH tube. Apart from physical examination, microstructural studies based on optical microscopy, SEM and EDX analysis were performed. The results of the investigation point out the limitation of Carbides precipitation at the alloyed steel/welding interface. This is synonym of creep stage I involvement in the failure of ITSH. Improper post-welding operation and bending moment are considered as root causes of the premature failure.

  12. Automatic crack detection method for loaded coal in vibration failure process.

    Directory of Open Access Journals (Sweden)

    Chengwu Li

    Full Text Available In the coal mining process, the destabilization of loaded coal mass is a prerequisite for coal and rock dynamic disaster, and surface cracks of the coal and rock mass are important indicators, reflecting the current state of the coal body. The detection of surface cracks in the coal body plays an important role in coal mine safety monitoring. In this paper, a method for detecting the surface cracks of loaded coal by a vibration failure process is proposed based on the characteristics of the surface cracks of coal and support vector machine (SVM. A large number of cracked images are obtained by establishing a vibration-induced failure test system and industrial camera. Histogram equalization and a hysteresis threshold algorithm were used to reduce the noise and emphasize the crack; then, 600 images and regions, including cracks and non-cracks, were manually labelled. In the crack feature extraction stage, eight features of the cracks are extracted to distinguish cracks from other objects. Finally, a crack identification model with an accuracy over 95% was trained by inputting the labelled sample images into the SVM classifier. The experimental results show that the proposed algorithm has a higher accuracy than the conventional algorithm and can effectively identify cracks on the surface of the coal and rock mass automatically.

  13. Non-Destructive Failure Detection and Visualization of Artificially and Naturally Aged PV Modules

    Directory of Open Access Journals (Sweden)

    Gabriele C. Eder

    2018-04-01

    Full Text Available Several series of six-cell photovoltaic test-modules—intact and with deliberately generated failures (micro-cracks, cell cracks, glass breakage and connection defects—were artificially and naturally aged. They were exposed to various stress conditions (temperature, humidity and irradiation in different climate chambers in order to identify (i the stress-induced effects; (ii the potential propagation of the failures and (iii their influence on the performance. For comparison, one set of test-modules was also aged in an outdoor test site. All photovoltaic (PV modules were thoroughly electrically characterized by electroluminescence and performance measurements before and after the accelerated ageing and the outdoor test. In addition, the formation of fluorescence effects in the encapsulation of the test modules in the course of the accelerated ageing tests was followed over time using UV-fluorescence imaging measurements. It was found that the performance of PV test modules with mechanical module failures was rather unaffected upon storage under various stress conditions. However, numerous micro-cracks led to a higher rate of degradation. The polymeric encapsulate of the PV modules showed the build-up of distinctive fluorescence effects with increasing lifetime as the encapsulant material degraded under the influence of climatic stress factors (mainly irradiation by sunlight and elevated temperature by forming fluorophores. The induction period for the fluorescence effects of the polymeric encapsulant to be detectable was ~1 year of outdoor weathering (in middle Europe and 300 h of artificial irradiation (with 1000 W/m2 artificial sunlight 300–2500 nm. In the presence of irradiation, oxygen—which permeated into the module through the polymeric backsheet—bleached the fluorescence of the encapsulant top layer between the cells, above cell cracks and micro-cracks. Thus, UV-F imaging is a perfect tool for on-site detection of module failures

  14. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  15. Failure of operative treatment for glenohumeral instability: etiology and management.

    Science.gov (United States)

    Shah, Apurva S; Karadsheh, Mark S; Sekiya, Jon K

    2011-05-01

    Failure of primary shoulder stabilization procedures is often related to uncorrected anatomic pathology. Orthopaedic surgeons must recognize excessive capsular laxity or large glenohumeral bone defects preoperatively to avoid recurrence of instability. When history, physical examination, and radiographic evaluation are used in conjunction, patients at risk for failure can be identified. The instability severity index score permits precise identification of patients at risk. When treating patients in whom prior surgical intervention has failed, the success of revision procedures correlates to the surgeon's ability to identify the essential pathology and use lesion-specific treatment strategies. Revision procedures remain technically demanding. Keen preoperative and intraoperative judgment is required to avoid additional recurrence of instability after revision procedures, particularly because results deteriorate with each successive operation. Glenoid or humeral defects with greater than 25% bone loss compromise stability provided through the mechanism of concavity compression. These defects must be specifically addressed to avoid recurrence of instability. We prefer anatomic reconstruction techniques combined with capsulolabral repair and, if bone defects are present, anatomic reconstruction with osteochondral allograft. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  17. JACoW Online analysis for anticipated failure diagnostics of the CERN cryogenic systems

    CERN Document Server

    Gayet, Philippe; Bradu, Benjamin; Cirillo, Roberta

    2018-01-01

    The cryogenic system is one of the most critical component of the CERN Large Hadron Collider (LHC) and its associated experiments ATLAS and CMS. In the past years, the cryogenic team has improved the maintenance plan and the operation procedures and achieved a very high reliability. However, as the recovery time after failure remains the major issue for the cryogenic availability new developments must take place. A new online diagnostic tool is developed to identify and anticipate failures of cryogenics field equipment, based on the acquired knowledge on dynamic simulation for the cryogenic equipment and on previous data analytic studies. After having identified the most critical components, we will develop their associated models together with the signature of their failure modes. The proposed tools will detect deviation between the actual systems and their model or identify preliminary failure signatures. This information will allow the operation team to take early mitigating actions before the failure occu...

  18. Sensitivity of the probability of failure to probability of detection curve regions

    International Nuclear Information System (INIS)

    Garza, J.; Millwater, H.

    2016-01-01

    Non-destructive inspection (NDI) techniques have been shown to play a vital role in fracture control plans, structural health monitoring, and ensuring availability and reliability of piping, pressure vessels, mechanical and aerospace equipment. Probabilistic fatigue simulations are often used in order to determine the efficacy of an inspection procedure with the NDI method modeled as a probability of detection (POD) curve. These simulations can be used to determine the most advantageous NDI method for a given application. As an aid to this process, a first order sensitivity method of the probability-of-failure (POF) with respect to regions of the POD curve (lower tail, middle region, right tail) is developed and presented here. The sensitivity method computes the partial derivative of the POF with respect to a change in each region of a POD or multiple POD curves. The sensitivities are computed at no cost by reusing the samples from an existing Monte Carlo (MC) analysis. A numerical example is presented considering single and multiple inspections. - Highlights: • Sensitivities of probability-of-failure to a region of probability-of-detection curve. • The sensitivities are computed with negligible cost. • Sensitivities identify the important region of a POD curve. • Sensitivities can be used as a guide to selecting the optimal POD curve.

  19. Development of a new code to solve hydro-mechanical coupling, shear failure and tensile failure due to hydraulic fracturing operations.

    Science.gov (United States)

    María Gómez Castro, Berta; De Simone, Silvia; Carrera, Jesús

    2016-04-01

    Nowadays, there are still some unsolved relevant questions which must be faced if we want to proceed to the hydraulic fracturing in a safe way. How much will the fracture propagate? This is one of the most important questions that have to be solved in order to avoid the formation of pathways leading to aquifer targets and atmospheric release. Will the fracture failure provoke a microseismic event? Probably this is the biggest fear that people have in fracking. The aim of this work (developed as a part of the EU - FracRisk project) is to understand the hydro-mechanical coupling that controls the shear of existing fractures and their propagation during a hydraulic fracturing operation, in order to identify the key parameters that dominate these processes and answer the mentioned questions. This investigation focuses on the development of a new C++ code which simulates hydro-mechanical coupling, shear movement and propagation of a fracture. The framework employed, called Kratos, uses the Finite Element Method and the fractures are represented with an interface element which is zero thickness. This means that both sides of the element lie together in the initial configuration (it seems a 1D element in a 2D domain, and a 2D element in a 3D domain) and separate as the adjacent matrix elements deform. Since we are working in hard, fragile rocks, we can assume an elastic matrix and impose irreversible displacements in fractures when rock failure occurs. The formulation used to simulate shear and tensile failures is based on the analytical solution proposed by Okada, 1992 and it is part of an iterative process. In conclusion, the objective of this work is to employ the new code developed to analyze the main uncertainties related with the hydro-mechanical behavior of fractures derived from the hydraulic fracturing operations.

  20. [PULMONARY COMPLICATIONS IN CHILDREN, OPERATED ON FOR INBORN HEART FAILURES IN THE ARTIFICIAL BLOOD CIRCULATION ENVIRONMENT].

    Science.gov (United States)

    Moshkivska, L V; Nastenko, E A; Golovenko, O S; Lazoryshynets, V V

    2015-11-01

    The risk factors of pulmonary complications occurrence were analyzed in children, operated on for inborn heart failures in atrificial blood circulation environment. Pulmonary complications rate and the risk factors of their occurrence were analyzed.

  1. Analysis on the effect of risk from containment failure by over-pressurization during the operation of containment filtered venting system

    International Nuclear Information System (INIS)

    Ham, Jaehyun; Kang, Hyun Gook; Chang, Soon Heung

    2015-01-01

    Passive safety systems which are operated without power source are suggested as a solution SBO. For containment protection system, Containment Filtered Venting System (CFVS) is suggested. CFVS controls the containment pressure by releasing the containment gas through filter passively without any power source. But because still small amount of radioactive material have no choice but to release to the environment, starting time and operation method of CFVS have to be determined carefully. Later starting time brings not only lower release but also higher risk from containment failure by over-pressurization, so it is a problem. In this research, the effect of risk from containment failure by over-pressurization during the operation of containment filtered venting system was analyzed. In this research, optimized values for variables of the CFVS operation method are found as 0.67 MPa, 9 cm, 0.1 MPa each for open pressure, pressure interval, and vent pipe diameter when DF as a function of time and risk from containment over-pressurization failure are considered. Generally in this research, release without risk get lower values in higher pressure, and lower vent pipe diameter. Release with risk get sharply high values when the containment pressure exceeds the design pressure because of the effect of risk from containment failure by over-pressurization. In conclusion, highest pressure, and lowest vent pipe diameter which are not influenced by risk is the optimized values for CFVS operation method because amount of risk is much larger than release through the CFVS

  2. Failure rate evaluation for different components operating in sodium, based on operating experience of the RAPSODIE and the PHENIX reactors and the test loops

    International Nuclear Information System (INIS)

    Boisseau, J.; Dorey, J.; Hedin, F.; Le Floch, C.

    1982-01-01

    The failure rates of the following components, valves operating in sodium, mechanical and electromagnetic pumps, and heat exchangers including intermediate heat exchangers, cold traps, steam generators, are evaluated by analysing the main incidents which occurred on these components. Therefore, this paper contains an evaluation of the operating experience of components working in sodium and of the reliability of these components

  3. Possibilities And Influencing Parameters For The Early Detection Of Sheet Metal Failure In Press Shop Operations

    International Nuclear Information System (INIS)

    Gerlach, Joerg; Kessler, Lutz; Paul, Udo; Roesen, Hartwig

    2007-01-01

    The concept of forming limit curves (FLC) is widely used in industrial practice. The required data should be delivered for typical material properties (measured on coils with properties in a range of +/- of the standard deviation from the mean production values) by the material suppliers. In particular it should be noted that its use for the validation of forming robustness providing forming limit curves for the variety of scattering in the mechanical properties is impossible. Therefore a forecast of the expected limit strains without expensive cost and time-consuming experiments is necessary. In the paper the quality of a regression analysis for determining forming limit curves based on tensile test results is presented and discussed.Owing to the specific definition of limit strains with FLCs following linear strain paths, the significance of this failure definition is limited. To consider nonlinear strain path effects, different methods are given in literature. One simple method is the concept of limit stresses. It should be noted that the determined value of the critical stress is dependent on the extrapolation of the tensile test curve. When the yield curve extrapolation is very similar to an exponential function, the definition of the critical stress value is very complicated due to the low slope of the hardening function at large strains.A new method to determine general failure behavior in sheet metal forming is the common use and interpretation of three criteria: onset on material instability (comparable with FLC concept), value of critical shear fracture and the value of ductile fracture. This method seems to be particularly successful for newly developed high strength steel grades in connection with more complex strain paths for some specific material elements. Nevertheless the identification of the different failure material parameters or functions will increase and the user has to learn with the interpretation of the numerical results

  4. A novelty detection diagnostic methodology for gearboxes operating under fluctuating operating conditions using probabilistic techniques

    Science.gov (United States)

    Schmidt, S.; Heyns, P. S.; de Villiers, J. P.

    2018-02-01

    In this paper, a fault diagnostic methodology is developed which is able to detect, locate and trend gear faults under fluctuating operating conditions when only vibration data from a single transducer, measured on a healthy gearbox are available. A two-phase feature extraction and modelling process is proposed to infer the operating condition and based on the operating condition, to detect changes in the machine condition. Information from optimised machine and operating condition hidden Markov models are statistically combined to generate a discrepancy signal which is post-processed to infer the condition of the gearbox. The discrepancy signal is processed and combined with statistical methods for automatic fault detection and localisation and to perform fault trending over time. The proposed methodology is validated on experimental data and a tacholess order tracking methodology is used to enhance the cost-effectiveness of the diagnostic methodology.

  5. Fission product release modelling for application of fuel-failure monitoring and detection - An overview

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, B.J., E-mail: lewibre@gmail.com [Department of Chemistry and Chemical Engineering, Royal Military College of Canada, Kingston, Ontario, K7K 7B4 (Canada); Chan, P.K.; El-Jaby, A. [Department of Chemistry and Chemical Engineering, Royal Military College of Canada, Kingston, Ontario, K7K 7B4 (Canada); Iglesias, F.C.; Fitchett, A. [Candesco Division of Kinectrics Inc., 26 Wellington Street East, 3rd Floor, Toronto, Ontario M5E 1S2 (Canada)

    2017-06-15

    A review of fission product release theory is presented in support of fuel-failure monitoring analysis for the characterization and location of defective fuel. This work is used to describe: (i) the development of the steady-state Visual-DETECT code for coolant activity analysis to characterize failures in the core and the amount of tramp uranium; (ii) a generalization of this model in the STAR code for prediction of the time-dependent release of iodine and noble gas fission products to the coolant during reactor start-up, steady-state, shutdown, and bundle-shifting manoeuvres; (iii) an extension of the model to account for the release of fission products that are delayed-neutron precursors for assessment of fuel-failure location; and (iv) a simplification of the steady-state model to assess the methodology proposed by WANO for a fuel reliability indicator for water-cooled reactors.

  6. Nonexplicit change detection in complex dynamic settings: what eye movements reveal.

    Science.gov (United States)

    Vachon, François; Vallières, Benoît R; Jones, Dylan M; Tremblay, Sébastien

    2012-12-01

    We employed a computer-controlled command-and-control (C2) simulation and recorded eye movements to examine the extent and nature of the inability to detect critical changes in dynamic displays when change detection is implicit (i.e., requires no explicit report) to the operator's task. Change blindness-the failure to notice significant changes to a visual scene-may have dire consequences on performance in C2 and surveillance operations. Participants performed a radar-based risk-assessment task involving multiple subtasks. Although participants were not required to explicitly report critical changes to the operational display, change detection was critical in informing decision making. Participants' eye movements were used as an index of visual attention across the display. Nonfixated (i.e., unattended) changes were more likely to be missed than were fixated (i.e., attended) changes, supporting the idea that focused attention is necessary for conscious change detection. The finding of significant pupil dilation for changes undetected but fixated suggests that attended changes can nonetheless be missed because of a failure of attentional processes. Change blindness in complex dynamic displays takes the form of failures in establishing task-appropriate patterns of attentional allocation. These findings have implications in the design of change-detection support tools for dynamic displays and work procedure in C2 and surveillance.

  7. Maritime Interdiction Operations Small Craft Detection

    International Nuclear Information System (INIS)

    Dougan, A.D.; Trombino, D.; Dunlop, W.; Bordetsky, A.

    2010-01-01

    The Naval Postgraduate School has been conducting Tactical Network Topology (TNT) Maritime Interdiction Operations (MIO) experiments with Lawrence Livermore National Laboratory (LLNL) since early in 2005. In this work, we are investigating cutting edge technology to evaluate use of networks, advanced sensors and collaborative technology for globally-supported maritime interdiction operations. Some examples of our research include communications in harsh environments, between moving ships at sea; small boat drive-by radiation detection; network-centric collaboration with global partners; situational awareness; prototype sensors and biometric instruments. Since 2006, we have studied the concept of using a small vessel with fixed radiation sensors to do initial searches for illicit radioactive materials. In our work, we continue to evaluate concepts of operation for small boat monitoring. For example, in San Francisco Bay we established a simulated choke point using two RHIBs. Each RHIB had a large sodium iodide radiation sensor on board, mounted on the side nearest to the passing potential target boats. Once detections were made, notification over the network prompted a chase RHIB also equipped with a radiation sensor to further investigate the potential target. We have also used an unmanned surface vessel (USV) carrying a radiation sensor to perform the initial discovery. The USV was controlled remotely and to drive by boats in different configurations. The potential target vessels were arranged in a line, as a choke point and randomly spaced in the water. Search plans were problematic when weather, waves and drift complicated the ability to stay in one place. A further challenge is to both detect and identify the radioactive materials during the drive-by. Our radiation detection system, ARAM, Adaptable Radiation Area Monitor, is able to detect, alarm and quickly identify plausible radionuclides in real time. We have performed a number of experiments to better

  8. Extended prediction rule to optimise early detection of heart failure in older persons with non-acute shortness of breath : A cross-sectional study

    NARCIS (Netherlands)

    Van Riet, Evelien E S; Hoes, Arno W.; Limburg, Alexander; Landman, Marcel A J; Kemperman, Hans; Rutten, Frans H.

    2016-01-01

    Objectives: There is a need for a practical tool to aid general practitioners in early detection of heart failure in the elderly with shortness of breath. In this study, such a screening rule was developed based on an existing rule for detecting heart failure in older persons with a diagnosis of

  9. Probability of failure of the watershed algorithm for peak detection in comprehensive two-dimensional chromatography

    NARCIS (Netherlands)

    Vivó-Truyols, G.; Janssen, H.-G.

    2010-01-01

    The watershed algorithm is the most common method used for peak detection and integration In two-dimensional chromatography However, the retention time variability in the second dimension may render the algorithm to fail A study calculating the probabilities of failure of the watershed algorithm was

  10. Metaiodobenzylguanidine [131I] scintigraphy detects impaired myocardial sympathetic neuronal transport function of canine mechanical-overload heart failure

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Rose, C.P.; Rouleau, J.L.

    1987-01-01

    In heart failure secondary to chronic mechanical overload, cardiac sympathetic neurons demonstrate depressed catecholamine synthetic and transport function. To assess the potential of sympathetic neuronal imaging for detection of depressed transport function, serial scintigrams were acquired after the intravenous administration of metaiodobenzylguanidine [ 131 I] to 13 normal dogs, 3 autotransplanted (denervated) dogs, 5 dogs with left ventricular failure, and 5 dogs with compensated left ventricular hypertrophy due to a surgical arteriovenous shunt. Nine dogs were killed at 14 hours postinjection for determination of metaiodobenzylguanidine [ 131 I] and endogenous norepinephrine content in left atrium, left ventricle, liver, and spleen. By 4 hours postinjection, autotransplanted dogs had a 39% reduction in mean left ventricular tracer accumulation, reflecting an absent intraneuronal tracer pool. Failure dogs demonstrated an accelerated early mean left ventricular tracer efflux rate (26.0%/hour versus 13.7%/hour in normals), reflecting a disproportionately increased extraneuronal tracer pool. They also showed reduced late left ventricular and left atrial concentrations of tracer, consistent with a reduced intraneuronal tracer pool. By contrast, compensated hypertrophy dogs demonstrated a normal early mean left ventricular tracer efflux rate (16.4%/hour) and essentially normal late left ventricular and left atrial concentrations of tracer. Metaiodobenzylguanidine [ 131 I] scintigraphic findings reflect the integrity of the cardiac sympathetic neuronal transport system in canine mechanical-overload heart failure. Metaiodobenzylguanidine [ 123 I] scintigraphy should be explored as a means of early detection of mechanical-overload heart failure in patients

  11. Analysis of the operator action and the single failure criteria in a SGTR sequence using best estimate assumptions with TRACE 5.0

    International Nuclear Information System (INIS)

    Jimenez, G.; Queral, C.; Rebollo-Mena, M.J.; Martínez-Murillo, J.C.; Lopez-Alonso, E.

    2013-01-01

    Highlights: ► Several worldwide SGTR deterministic safety analysis methodologies were analyze to study the different assumption made. ► The most relevant assumptions for operation action and single failure criteria are compared through TRACE simulations.► The offsite dose results showed the adequacy of the assumptions included in the analyzed methodologies. ► Two proposal of change for SGTR Emergency Operating Procedure are outlined to minimize the dose in case of a SGTR accident. - Abstract: Steam Generator Tube Rupture (SGTR) sequences in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are a special kind of transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path from the reactor coolant system to the environment. The first methodology used to perform the Deterministic Safety Analysis (DSA) of a SGTR did not credit the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that period of time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that the operators usually take more than 30 min to stop the leakage in actual sequences. Some methodologies were raised to overcome that fact, considering operator actions from the beginning of the transient, as it is done in Probabilistic Safety Analysis. This paper presents the results of comparing different assumptions regarding the single failure criteria and the operator action taken from the most common methodologies included in the different Deterministic Safety Analysis. One single failure criteria that has not been analysed previously in the literature is proposed and analysed in this paper too. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP) with best estimate assumptions but including

  12. Operational Failures Caused by Arrogant Leaders

    National Research Council Canada - National Science Library

    Parrington, James R

    2008-01-01

    .... The failures of the Japanese and U.S. militaries directly resulted from the professional arrogance exhibited by Admiral Yamamoto and Secretary Rumsfeld as they deliberately limited the scope of their strategic thinking to how their...

  13. A neuro-fuzzy inference system for sensor failure detection using wavelet denoising, PCA and SPRT

    International Nuclear Information System (INIS)

    Na, Man Gyun

    2001-01-01

    In this work, a neuro-fuzzy inference system combined with the wavelet denoising, PCA(principal component analysis) and SPRT (sequential probability ratio test) methods is developed to detect the relevant sensor failure using other sensor signals. The wavelet denoising technique is applied to remove noise components in input signals into the neuro-fuzzy system. The PCA is used to reduce the dimension of an input space without losing a significant amount of information, The PCA makes easy the selection of the input signals into the neuro-fuzzy system. Also, a lower dimensional input space usually reduces the time necessary to train a neuro-fuzzy system. The parameters of the neuro-fuzzy inference system which estimates the relevant sensor signal are optimized by a genetic algorithm and a least-squares algorithm. The residuals between the estimated signals and the measured signals are used to detect whether the sensors are failed or not. The SPRT is used in this failure detection algorithm. The proposed sensor-monitoring algorithm was verified through applications to the pressurizer water level and the hot-leg flowrate sensors in pressurized water reactors

  14. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  15. Learning lessons from accidents with a human and organisational factors perspective: deficiencies and failures of operating experience feedback systems

    International Nuclear Information System (INIS)

    Dechy, N.; Rousseau, J.M.; Jeffroy, F.

    2012-01-01

    This paper aims at reminding the failures of operating experience feedback (OEF) systems through the lessons of accidents and provides a framework for improving the efficiency of OEF processes. The risk is for example to miss lessons from other companies and industrial sectors, or to miss the implementation of adequate corrective actions with the risk to repeat accidents. Most of major accidents have been caused by a learning failure or other organisational factors as a contributing cause among several root causes. Some of the recurring organisational factors are: -) poor recognition of critical components, of critical activities or deficiency in anticipation and detection of errors, -) excessive production pressure, -) deficiency of communication or lack of quality of dialogue, -) Excessive formalism, -) organisational complexity, -) learning deficiencies (OEF, closing feedback loops, lack of listening of whistle-blowers). Some major accidents occurred in the nuclear industry. Although the Three Mile Island accident has multiple causes, in particular, an inappropriate design of the man-machine interface, it is a striking example of the loss of external lessons from incidents. As for Fukushima it is too early to have established evidence on learning failures. The systematic study and organisational analysis of OEF failures in industrial accidents whatever their sector has enabled us to provide a framework for OEF improvements. Five key OEF issues to improve in priority: 1) human and organisational factors analysis of the root causes of the events, 2) listening to the field staff, dissenting voices and whistle-blowers, 3) monitoring of the external events that provide generic lessons, 4) building an alive memory through a culture of accidents with people who become experiences pillars, and 5) the setting of external audit or organisational analysis of the OEF system by independent experts. The paper is followed by the slides of the presentation

  16. Noise diagnosis - a method for early detection of failures in a nuclear plant

    International Nuclear Information System (INIS)

    Brinckmann, H.F.

    1981-01-01

    Noise diagnosis constitutes one method for early detection of plant failures. The method is based on the fact that nearly all undesired processes in a nuclear power plant make a measurable contribution to the noise portion of signals. Well-known examples of undesired processes in pressurized water reactors include core-barrel movement, the vibration of control elements, the appearance of loose parts in the coolant flow, and the process of coolant boiling. Each of these processes has been implicated in past nuclear plant failures. In the German Democratic Republic (GDR) P. Liewers and his colleagues have introduced noise analysis systems into the primary circuit of WWER-440 pressurized water reactors (PWR). The most progressive version (RAS-II) has become a prototype for research and routine investigations. This system is described. (author)

  17. A population based study of variations in operation rates for breast cancer, of comorbidity and prognosis at diagnosis: failure to operate for early breast cancer in older women.

    Science.gov (United States)

    Bates, T; Evans, T; Lagord, C; Monypenny, I; Kearins, O; Lawrence, G

    2014-10-01

    Older women are less likely to have surgery for operable breast cancer. This population-based study examines operation rates by age and identifies groups which present with early or late disease. 37 000 cancer registrations for 2007 were combined with Hospital Episode Statistics comorbidity data for England. Operation rates were examined by age, ethnicity, deprivation, comorbidity, screen-detection, tumour size, grade and nodal status. Early and late presentation were correlated with Nottingham Prognostic Index (NPI) groups and tumour size. The proportion of women not having surgery increased from 7-10% at ages 35-69 to 82% from age 90. From age 70, the proportion not having surgery rose by an average of 3.1% per year of age. Women with a Charlson Comorbidity Index score of ≥1 (which increased with age), with tumours >50 mm or who were node positive, were less likely to have surgery. Although women aged 70-79 were more likely to have larger tumours, their tumours were also more likely to have an excellent or good NPI (p ethnic groups (p ethnic groups presented with more advanced tumours. Older women had larger tumours which were otherwise of good prognosis, and this would not account for the failure to operate which may in part be related to comorbidity in this age group. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Acoustic Emission Monitoring of Incipient in Journal Bearings - Part I : Detectability and measurement for bearing damages

    International Nuclear Information System (INIS)

    Yoon, Dong Jin; Kwon, Oh Yang; Chung, Min Hwa; Kim, Kyung Woong

    1994-01-01

    In contrast to the machinery using rolling element bearings, systems with journal bearings generally operate in large scale and under severe loading condition such as steam generator turbines and internal combustion engines. Failure of the bearings in these machinery can result in the system breakdown. To avoid the time consuming repair and considerable economic loss, the detection of incipient failure in journal bearings becomes very important. In this experimental approach, acoustic emission monitoring is applied to the detection of incipient failure caused by several types of abnormal operating condition most probable in the journal bearing systems. It has been known that the intervention of foreign materials, insufficient lubrication and misassembly etc. are principal factors to cause bearing failure and distress. The experiment was conducted under such designed conditions as hard particles in the lubrication layer, insufficient lubrication, and metallic contact in the simulated journal bearing system. The results showed that acoustic emission could be an effective tool to detect the incipient failure in journal bearings

  19. Detection of failures of axle-bearings of railway vehicles

    Directory of Open Access Journals (Sweden)

    Bižić Milan B.

    2016-01-01

    Full Text Available The failure of axle-bearing is one of the most common causes of derailments of railway vehicles which are usually accompanied by huge material damage and human casualties. Modern railways are working intensively on the development and implementation of appropriate systems for early detection of axlebearing malfunctions, which are typically manifested by increasing of its temperature. The most common approach is based on the use of wayside systems or checkpoints located in certain places along the track. There is also an innovative approach that involves using the system for continuous measuring and online monitoring of axle-boxes temperature. The main aim is to provide early detection of malfunctions of the axle-bearing and prevention of the potential derailment. This paper analyses the existing solutions for the detection of axle-bearings malfunctions with special emphasis on the working principle and the main advantages and disadvantages. The paper presents the basics of the one newly developed wireless measuring system for on-line monitoring of axle-boxes temperature. The measuring system was tested in real conditions and can be successfully applied to the commercial railway vehicles. The main conclusion is that systems for on-line monitoring of axle-bearings temperatures are far more efficient than wayside systems. Obtained results may be important for those who deal with these and similar problems, problems of development, exploitation and maintenance of railway vehicles, strategies, regulations, etc.

  20. Study on operation of a research reactor during one PCS pump failure accident

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed.

  1. Study on operation of a research reactor during one PCS pump failure accident

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon

    2012-01-01

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed

  2. Neural fraud detection in credit card operations.

    Science.gov (United States)

    Dorronsoro, J R; Ginel, F; Sgnchez, C; Cruz, C S

    1997-01-01

    This paper presents an online system for fraud detection of credit card operations based on a neural classifier. Since it is installed in a transactional hub for operation distribution, and not on a card-issuing institution, it acts solely on the information of the operation to be rated and of its immediate previous history, and not on historic databases of past cardholder activities. Among the main characteristics of credit card traffic are the great imbalance between proper and fraudulent operations, and a great degree of mixing between both. To ensure proper model construction, a nonlinear version of Fisher's discriminant analysis, which adequately separates a good proportion of fraudulent operations away from other closer to normal traffic, has been used. The system is fully operational and currently handles more than 12 million operations per year with very satisfactory results.

  3. Plan of studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Nagahara, T.; Hattori, M.; Kawaguchi, K.

    1987-01-01

    Studies on fuel failure detection in Rikkyo Research Reactor have recently been begun in the following four approaches. (1) Accumulation of the data on the concentration of the short-lived radioactivity originating from FP rare gases contained in the air on the water surface of the reactor tank. (2) Accumulation of the data on the concentration of FP (especially 131 I) in the water of the reactor tank. (3) Design and preparation of a ''sniffer'' by which the location of the failed fuel element can be detected, when some anomaly is found in the above two routine measurements. (4) Design and preparation of a vessel containing a fuel element, which can be useful both for ''sipping'' inspection of the fuel element and for storage of the damaged fuel element. In this paper, an outline of the above approaches and the results of some preliminary experiments are reported. (author)

  4. Human error recovery failure probability when using soft controls in computerized control rooms

    International Nuclear Information System (INIS)

    Jang, Inseok; Kim, Ar Ryum; Seong, Poong Hyun; Jung, Wondea

    2014-01-01

    Many literatures categorized recovery process into three phases; detection of problem situation, explanation of problem causes or countermeasures against problem, and end of recovery. Although the focus of recovery promotion has been on categorizing recovery phases and modeling recovery process, research related to human recovery failure probabilities has not been perform actively. On the other hand, a few study regarding recovery failure probabilities were implemented empirically. Summarizing, researches that have performed so far have several problems in terms of use in human reliability analysis (HRA). By adopting new human-system interfaces that are based on computer-based technologies, the operation environment of MCRs in NPPs has changed from conventional MCRs to advanced MCRs. Because of the different interfaces between conventional and advanced MCRs, different recovery failure probabilities should be considered in the HRA for advanced MCRs. Therefore, this study carries out an empirical analysis of human error recovery probabilities under an advanced MCR mockup called compact nuclear simulator (CNS). The aim of this work is not only to compile a recovery failure probability database using the simulator for advanced MCRs but also to collect recovery failure probability according to defined human error modes to compare that which human error mode has highest recovery failure probability. The results show that recovery failure probability regarding wrong screen selection was lowest among human error modes, which means that most of human error related to wrong screen selection can be recovered. On the other hand, recovery failure probabilities of operation selection omission and delayed operation were 1.0. These results imply that once subject omitted one task in the procedure, they have difficulties finding and recovering their errors without supervisor's assistance. Also, wrong screen selection had an effect on delayed operation. That is, wrong screen

  5. Development of a morphological convolution operator for bearing fault detection

    Science.gov (United States)

    Li, Yifan; Liang, Xihui; Liu, Weiwei; Wang, Yan

    2018-05-01

    This paper presents a novel signal processing scheme, namely morphological convolution operator (MCO) lifted morphological undecimated wavelet (MUDW), for rolling element bearing fault detection. In this scheme, a MCO is first designed to fully utilize the advantage of the closing & opening gradient operator and the closing-opening & opening-closing gradient operator for feature extraction as well as the merit of excellent denoising characteristics of the convolution operator. The MCO is then introduced into MUDW for the purpose of improving the fault detection ability of the reported MUDWs. Experimental vibration signals collected from a train wheelset test rig and the bearing data center of Case Western Reserve University are employed to evaluate the effectiveness of the proposed MCO lifted MUDW on fault detection of rolling element bearings. The results show that the proposed approach has a superior performance in extracting fault features of defective rolling element bearings. In addition, comparisons are performed between two reported MUDWs and the proposed MCO lifted MUDW. The MCO lifted MUDW outperforms both of them in detection of outer race faults and inner race faults of rolling element bearings.

  6. Predictors of treatment failure and time to detection and switching in HIV-infected Ethiopian children receiving first line anti-retroviral therapy

    Directory of Open Access Journals (Sweden)

    Bacha Tigist

    2012-08-01

    Full Text Available Abstract Background The emergence of resistance to first line antiretroviral therapy (ART regimen leads to the need for more expensive and less tolerable second line drugs. Hence, it is essential to identify and address factors associated with an increased probability of first line ART regimen failure. The objective of this article is to report on the predictors of first line ART regimen failure, the detection rate of ART regime failure, and the delay in switching to second line ART drugs. Methods A retrospective cohort study was conducted from 2005 to 2011. All HIV infected children under the age of 15 who took first line ART for at least six months at the four major hospitals of Addis Ababa, Ethiopia were included. Data were collected, entered and analyzed using Epi info/ENA version 3.5.1 and SPSS version 16. The Cox proportional-hazard model was used to assess the predictors of first line ART failure. Results Data of 1186 children were analyzed. Five hundred seventy seven (48.8% were males with a mean age of 6.22 (SD = 3.10 years. Of the 167(14.1% children who had treatment failure, 70 (5.9% had only clinical failure, 79 (6.7% had only immunologic failure, and 18 (1.5% had both clinical and immunologic failure. Patients who had height for age in the third percentile or less at initiation of ART were found to have higher probability of ART treatment failure [Adjusted Hazard Ratio (AHR, 3.25 95% CI, 1.00-10.58]. Patients who were less than three years old [AHR, 1.85 95% CI, 1.24-2.76], chronic diarrhea after initiation of antiretroviral treatment [AHR, 3.44 95% CI, 1.37-8.62], ART drug substitution [AHR, 1.70 95% CI, 1.05-2.73] and base line CD4 count below 50 cells/mm3 [AHR, 2.30 95% CI, 1.28-4.14] were also found to be at higher risk of treatment failure. Of all the 167 first line ART failure cases, only 24 (14.4% were switched to second line ART with a mean delay of 24 (SD = 11.67 months. The remaining 143 (85.6% cases were diagnosed

  7. An empirical study on the human error recovery failure probability when using soft controls in NPP advanced MCRs

    International Nuclear Information System (INIS)

    Jang, Inseok; Kim, Ar Ryum; Jung, Wondea; Seong, Poong Hyun

    2014-01-01

    Highlights: • Many researchers have tried to understand human recovery process or step. • Modeling human recovery process is not sufficient to be applied to HRA. • The operation environment of MCRs in NPPs has changed by adopting new HSIs. • Recovery failure probability in a soft control operation environment is investigated. • Recovery failure probability here would be important evidence for expert judgment. - Abstract: It is well known that probabilistic safety assessments (PSAs) today consider not just hardware failures and environmental events that can impact upon risk, but also human error contributions. Consequently, the focus on reliability and performance management has been on the prevention of human errors and failures rather than the recovery of human errors. However, the recovery of human errors is as important as the prevention of human errors and failures for the safe operation of nuclear power plants (NPPs). For this reason, many researchers have tried to find a human recovery process or step. However, modeling the human recovery process is not sufficient enough to be applied to human reliability analysis (HRA), which requires human error and recovery probabilities. In this study, therefore, human error recovery failure probabilities based on predefined human error modes were investigated by conducting experiments in the operation mockup of advanced/digital main control rooms (MCRs) in NPPs. To this end, 48 subjects majoring in nuclear engineering participated in the experiments. In the experiments, using the developed accident scenario based on tasks from the standard post trip action (SPTA), the steam generator tube rupture (SGTR), and predominant soft control tasks, which are derived from the loss of coolant accident (LOCA) and the excess steam demand event (ESDE), all error detection and recovery data based on human error modes were checked with the performance sheet and the statistical analysis of error recovery/detection was then

  8. Nonparametric method for failures detection and localization in the actuating subsystem of aircraft control system

    Science.gov (United States)

    Karpenko, S. S.; Zybin, E. Yu; Kosyanchuk, V. V.

    2018-02-01

    In this paper we design a nonparametric method for failures detection and localization in the aircraft control system that uses the measurements of the control signals and the aircraft states only. It doesn’t require a priori information of the aircraft model parameters, training or statistical calculations, and is based on algebraic solvability conditions for the aircraft model identification problem. This makes it possible to significantly increase the efficiency of detection and localization problem solution by completely eliminating errors, associated with aircraft model uncertainties.

  9. Instrument failure detection of flow measurement in the feedwater system of the Paks Nuclear Power Plant, Hungary

    International Nuclear Information System (INIS)

    Racz, A.

    1990-12-01

    The applicability of two different methods for early detection of instrument failures of the flow measurement in feedwater systems are investigated. Both methods are based on Kalman filtering technique of stochastic processes. The reliability of the model for description of a feedwater system is checked by comparing calculated values with measured data. Possible instrument failures are simulated in order to show the capability of the proposed procedures. A practical measurement system arrangement is suggested. (author) 10 refs.; 16 figs.; 4 tabs

  10. Assessment of nonintrusive methods for monitoring the operational readiness of solenoid-operated valves

    International Nuclear Information System (INIS)

    Kryter, R.C.

    1988-01-01

    Solenoid-operated valves (SOVs) are being studied at Oak Ridge National Laboratory as part of the USNRC Nuclear Plant Aging Research (NPAR) Program. The primary objective of the study is to identify and recommend methods for inspection, surveillance, and maintenance of SOVs that can ensure their operational readiness-- that is, their ability to perform required safety functions under all anticipated operating conditions. An earlier (Phase I) study described SOV failure modes and causes and identified measurable parameters that might be used to monitor the various degradations that lead to functional failure. The present (Phase II) study focuses on devising and then demonstrating the effectiveness of techniques and/or equipment with which to measure the previously identified performance parameters and thus detect and trend the progress of any degradation. Several nonintrusive techniques are currently under investigation. Recent experimental results which demonstrate the feasibility and practicality of the techniques being studied are presented. 4 refs., 6 figs., 2 tabs

  11. The development and application of overheating failure model of FBR steam generator tubes. 2

    International Nuclear Information System (INIS)

    Miyake, Osamu; Hamada, Hirotsugu; Tanabe, Hiromi

    2001-11-01

    The JNC technical report 'The Development and Application of Overheating Failure Model of FBR Steam Generator Tubes' summarized the assessment method and its application for the overheating tube failure in an event of sodium-water reaction accident of fast breeder reactor's steam generators (SGs). This report describes the following items studied after the publication of the above technical report. 1. On the basis of the SWAT-3 experimental data, realistic local heating conditions (reaction zone temperature and related heat transfer conditions) for the sodium-water reaction were proposed. New correlations are cosine-shaped temperature profiles with 1,170 C maximum for the 100% and 40% Monju operating conditions, and those with 1,110 C maximum for the 10% condition. 2. For the cooling effects inside of target tubes, LWR's studies of critical heat flux (CHF) and post-CHF heat transfer correlations have been examined and considered in the assessment. The revised assessment adopts the Katto's correlation for CHF, and the Condie-Bengston IV correlation for post-CHF. 3. Other additional examination for the assessment includes treatments of the whole heating effect (other than the local reaction zone) due to the sodium-water reaction, and the temperature-dependent thermal properties of the heat transfer tube material (2.25Cr-1Mo steel). The revised overheating tube failure assessment method has been applied to the Monju SG studies. It is revealed consequently that no tube failure occurs in 100%, 40%, and 10% operating conditions when an initial leak is detected by the cover gas pressure detection system. The assessment for the SG system improved for the detection and blowdown systems shows even better safety margins against the overheating tube failure. (author)

  12. LYAPUNOV-Based Sensor Failure Detection and Recovery for the Reverse Water Gas Shift Process

    Science.gov (United States)

    Haralambous, Michael G.

    2002-01-01

    Livingstone, a model-based AI software system, is planned for use in the autonomous fault diagnosis, reconfiguration, and control of the oxygen-producing reverse water gas shift (RWGS) process test-bed located in the Applied Chemistry Laboratory at KSC. In this report the RWGS process is first briefly described and an overview of Livingstone is given. Next, a Lyapunov-based approach for detecting and recovering from sensor failures, differing significantly from that used by Livingstone, is presented. In this new method, models used are in t e m of the defining differential equations of system components, thus differing from the qualitative, static models used by Livingstone. An easily computed scalar inequality constraint, expressed in terms of sensed system variables, is used to determine the existence of sensor failures. In the event of sensor failure, an observer/estimator is used for determining which sensors have failed. The theory underlying the new approach is developed. Finally, a recommendation is made to use the Lyapunov-based approach to complement the capability of Livingstone and to use this combination in the RWGS process.

  13. Ultra-Sensitive NT-proBNP Quantification for Early Detection of Risk Factors Leading to Heart Failure

    Directory of Open Access Journals (Sweden)

    Keum-Soo Song

    2017-09-01

    Full Text Available Cardiovascular diseases such as acute myocardial infarction and heart failure accounted for the death of 17.5 million people (31% of all global deaths in 2015. Monitoring the level of circulating N-terminal proBNP (NT-proBNP is crucial for the detection of people at risk of heart failure. In this article, we describe a novel ultra-sensitive NT-proBNP test (us-NT-proBNP that allows the quantification of circulating NT-proBNP in 30 min at 25 °C in the linear detection range of 7.0–600 pg/mL. It is a first report on the application of a fluorescence bead labeled detection antibody, DNA-guided detection method, and glass fiber membrane platform for the quantification of NT-proBNP in clinical samples. Limit of blank, limit of detection, and limit of quantification were 2.0 pg/mL, 3.7 pg/mL, and 7 pg/mL, respectively. The coefficient of variation was found to be less than 10% in the entire detection range of 7–600 pg/mL. The test demonstrated specificity for NT-proBNP without interferences from bilirubin, intra-lipid, biotin, and hemoglobin. The serial dilution test for plasma samples containing various NT-proBNP levels showed the linear decrement in concentration with the regression coefficient of 0.980–0.998. These results indicate that us-NT-proBNP test does not suffer from the interference of the plasma components for the measurement of NT-proBNP in clinical samples.

  14. Fuel failure detection device

    International Nuclear Information System (INIS)

    Katagiri, Masaki.

    1979-01-01

    Purpose: To improve the SN ratio in the detection. Constitution: Improved precipitator method is provided. Scintillation detectors of a same function are provided respectively by each one before and after a gas reservoir for depositing fission products in the cover gas to detecting wires. The outputs from the two detectors (output from the wire not deposited with the fission products and the output from the wire after deposition) are compared to eliminate background noises resulted from not-decayed nucleides. A subtraction circuit is provided for the elimination. Since the background noises of the detecting wire can thus be measured and corrected on every detection, the SN ratio can be increased. (Ikeda, J.)

  15. Operative shortening of the sling as a second-line treatment after TVT failure

    Science.gov (United States)

    Matuszewski, Marcin; Michajłowski, Jerzy; Krajka, Kazimierz

    2011-01-01

    Introduction Stress urinary incontinence (SUI) is defined as an involuntary loss of urine during physical exertion, sneezing, coughing, laughing, or other activities that put pressure on the bladder. In some cases, recurrent or persistent SUI after sling operations may be caused by too loose placement of the sling. In the current study, we describe our method of shortening of the sling as a second-line treatment of tension-free vaginal tape (TVT) failure. Materials and methods Four women, aged 46-61, after initial TVT operation were treated for persistent SUI. The severity of SUI was estimated by: physical examinations, cough tests, 24-h pad tests, and King's Health Questionnaire. The shortening procedure, based on excising the fragment of tape and suturing it back, was performed in all patients. Results All cases achieved a good result, which was defined as restoration of full continence. No complications occurred. The 12-month follow-up showed no side-effects. The postoperative control tests: the cough and 24-h pad tests were negative in all women. The general health perceptions increased after the shortening procedure by a mean value 44.25%. The incontinence impact decreased by a mean value 44.6%. In all patients, role and physical limitations significantly decreased (by 88.5% and 80.5%, respectively). The negative emotions connected with SUI significantly decreased after the second procedure. Conclusions The operative shortening of the implanted sling is a simple, cheap, and effective method of second-line treatment in cases of TVT failure and may be offered to the majority of patients with insufficient urethral support after the first procedure. PMID:24578885

  16. SOR-ring failure

    International Nuclear Information System (INIS)

    Kitamura, Hideo

    1981-01-01

    It was in the autumn of 1976 that the SOR-ring (synchrotron radiation storage ring) has commenced the regular operation. Since then, the period when the operation was interrupted due to the failures of SOR-ring itself is in total about 8 weeks. Failures and accidents have occurred most in the vacuum system. Those failure experiences are described on the vacuum, electromagnet, radio-frequency acceleration and beam transport systems with their interrupted periods. The eleven failures in the vacuum system have been reported, such as bellows breakage in a heating-evacuating period, leakage from the bellows of straight-through valves (made in U.S.A. and Japan), and leakage from the joint flange of the vacuum system. The longest interruption was 5 weeks due to the failure of a domestically manufactured straight-through valve. The failures of the electromagnet system involve the breakage in a cooling water system, short circuit of a winding in the Q magnet power transformer, blow of a fuse protecting the deflection magnet power source by the current less than the rating, and others. The failures of the RF acceleration system include the breakage of an output electronic tube the breakage of a cavity ceramic, RF voltage fluctuation due to the contact deterioration at a cavity electrode, and the failure of grid bias power source. It is necessary to select the highly reliable components for the vacuum system because the vacuum system failures require longer time for recovery, and very likely to induce secondary and tertiary failures. (Wakatsuki, Y.)

  17. Common Cause Failure Analysis of Control Rods and Drives in the Swedish and Finnish BWR Plants. Operating Experiences in 1983 - 2003

    Energy Technology Data Exchange (ETDEWEB)

    Mankamo, Tuomas [Avaplan Oy, Espoo (Finland)

    2006-11-15

    The control rod and drives in a Boiling Water Reactor (BWR) constitute a highly redundant system. The reliability of the system is determined by how well the design withstands dependencies, as Common Cause Failures (CCFs). This report upgrades an earlier data collection on CCFs of control rod and drives (SKI Report 1996:77) to more recent years, with the objective to report the data to ICDE project (International Common Cause Failure Data Exchange) and to the safety analysts in the Nordic countries. The operating experiences were analyzed at the BWRs of former Asea-Atom design, comprising 9 units in Sweden and Olkiluoto 1 and 2 in Finland, covering years 1983 - 2003. A new logical scheme was developed to classify interconnected failure modes of the two redundant functions for reactivity shutdown, fast hydraulic insertion and slower screw insertion of control rods. The scheme makes an explicit distinction between the different attributes of the failure event: - affected function - affected movement direction - detectability - criticality, i.e. inoperable control rod function versus only degraded functionality Another novel idea emerged for grouping the events according to generic failure mechanism. The generic classes will help to organize and structure the information efficiently, because in most cases within a class, the failure modes prove to be same, or there are only a few alternatives to chose from. From the set of 72 candidate cases, altogether 27 actual or more significant potential CCFs were screened out. Special emphasis was placed to identify any multiple failure or degradation indicating that adjacent rods would be more vulnerable to failure, because such phenomena are far more critical for reactivity shutdown as compared to failure of randomly placed rods. Only slight tendency of position dependence could be determined. Another positive insight is that the events, where foreign objects caused the jamming of rod insertion, were separated by both

  18. Detecting and mitigating inverter aging

    International Nuclear Information System (INIS)

    Gunther, W.E.; Taylor, J.H.; Aggarwal, S.K.

    1988-01-01

    Nuclear power plants use inverters to supply power to safety-related equipment, instrumentation, and controls. They convert direct current (dc) to alternating current (ac) power, thereby making low voltage ac power available even under a station blackout condition. As part of the U.S. NRC's nuclear plant aging research (NPAR) program, the operating experience of this equipment has been analyzed to determine the dominant failure modes and causes. This paper summarizes that data, and then describes methods which can be employed to detect inverter degradation prior to failure, as well as methods to minimize the failure effects. In both cases, the mitigation of inverter aging is emphasized

  19. Avoidance Behavior against Positive Allergens Detected with a Multiple Allergen Simultaneous Test Immunoblot Assay in Patients with Urticaria: Factors Associated with Avoidance Success/Failure.

    Science.gov (United States)

    Lee, Min Kyung; Kwon, In Ho; Kim, Han Su; Kim, Heung Yeol; Cho, Eun Byul; Bae, Youin; Park, Gyeong Hun; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2016-02-01

    Avoidance behavior against positive allergens detected by using multiple allergen simultaneous test (MAST)-immunoblot assay in patients with urticaria has been rarely reported. We aimed to assess the avoidance behavior of patients with urticaria against positive allergens detected with a MAST. One hundred and one urticaria patients who showed positivity to at least one allergen on a MAST completed a questionnaire regarding their test results. The avoidance behavior of the patients was evaluated, and relevant determining factors of avoidance success/failure were statistically assessed. We detected 144 different data (n=51, food allergens; n=17, pollen allergens; and n=76, aeroallergens) from 101 patients with urticaria. The avoidance failure rates were 33.3% for food allergens, 70.6% for pollen allergens, and 30.3% for aeroallergens. The pollen group showed a significantly higher avoidance failure rate than the food and aeroallergen groups (psuccessfully avoid allergens (psuccess or failure against allergens in patients with urticaria when clinicians conduct allergen-specific immunoglobulin E tests.

  20. Lessons learned from failure analysis

    International Nuclear Information System (INIS)

    Le May, I.

    2006-01-01

    Failure analysis can be a very useful tool to designers and operators of plant and equipment. It is not simply something that is done for lawyers and insurance companies, but is a tool from which lessons can be learned and by means of which the 'breed' can be improved. In this presentation, several failure investigations that have contributed to understanding will be presented. Specifically, the following cases will be discussed: 1) A fire at a refinery that occurred in a desulphurization unit. 2) The failure of a pipeline before it was even put into operation. 3) Failures in locomotive axles that took place during winter operation. The refinery fire was initially blamed on defective Type 321 seamless stainless steel tubing, but there were conflicting views between 'experts' involved as to the mechanism of failure and the writer was called upon to make an in-depth study. This showed that there were a variety of failure mechanism involved, including high temperature fracture, environmentally-induced cracking and possible manufacturing defects. The unraveling of the failure sequence is described and illustrated. The failure of an oil transmission was discovered when the line was pressure tested some months after it had been installed and before it was put into service. Repairs were made and failure occurred in another place upon the next pressure test being conducted. After several more repairs had been made the line was abandoned and a lawsuit was commenced on the basis that the steel was defective. An investigation disclosed that the material was sensitive to embrittlement and the causes of this were determined. As a result, changes were made in the microstructural control of the product to avoid similar problems in future. A series of axle failures occurred in diesel electric locomotives during winter. An investigation was made to determine the nature of the failures which were not by classical fatigue, nor did they correspond to published illustrations of Cu

  1. An Investigation of Digital Instrumentation and Control System Failure Modes

    International Nuclear Information System (INIS)

    Korsah, Kofi; Cetiner, Mustafa Sacit; Muhlheim, Michael David; Poore, Willis P. III

    2010-01-01

    A study sponsored by the Nuclear Regulatory Commission study was conducted to investigate digital instrumentation and control (DI and C) systems and module-level failure modes using a number of databases both in the nuclear and non-nuclear industries. The objectives of the study were to obtain relevant operational experience data to identify generic DI and C system failure modes and failure mechanisms, and to obtain generic insights, with the intent of using results to establish a unified framework for categorizing failure modes and mechanisms. Of the seven databases studied, the Equipment Performance Information Exchange database was found to contain the most useful data relevant to the study. Even so, the general lack of quality relative to the objectives of the study did not allow the development of a unified framework for failure modes and mechanisms of nuclear I and C systems. However, an attempt was made to characterize all the failure modes observed (i.e., without regard to the type of I and C equipment under consideration) into common categories. It was found that all the failure modes identified could be characterized as (a) detectable/preventable before failures, (b) age-related failures, (c) random failures, (d) random/sudden failures, or (e) intermittent failures. The percentage of failure modes characterized as (a) was significant, implying that a significant reduction in system failures could be achieved through improved online monitoring, exhaustive testing prior to installation, adequate configuration control or verification and validation, etc.

  2. Shoreline Erosion and Slope Failure Detection over Southwest Lakeshore Michigan using Temporal Radar and Digital Elevation Model

    Science.gov (United States)

    Sataer, G.; Sultan, M.; Yellich, J. A.; Becker, R.; Emil, M. K.; Palaseanu, M.

    2017-12-01

    Throughout the 20th century and into the 21st century, significant losses of residential, commercial and governmental property were reported along the shores of the Great Lakes region due to one or more of the following factors: high lake levels, wave actions, groundwater discharge. A collaborative effort (Western Michigan University, University of Toledo, Michigan Geological Survey [MGS], United States Geological Survey [USGS], National Oceanographic and Atmospheric Administration [NOAA]) is underway to examine the temporal topographic variations along the shoreline and the adjacent bluff extending from the City of South Haven in the south to the City of Saugatuck in the north within the Allegan County. Our objectives include two main tasks: (1) identification of the timing of, and the areas, witnessing slope failure and shoreline erosion, and (2) investigating the factors causing the observed failures and erosion. This is being accomplished over the study area by: (1) detecting and measuring slope subsidence rates (velocities along line of site) and failures using radar interferometric persistent scatter (PS) techniques applied to ESA's European Remote Sensing (ERS) satellites, ERS-1 and -2 (spatial resolution: 25 m) that were acquired in 1995 to 2007, (2) extracting temporal high resolution (20 cm) digital elevation models (DEM) for the study area from temporal imagery acquired by Unmanned Aerial Vehicles (UAVs), and applying change detection techniques to the extracted DEMs, (3) detecting change in elevation and slope profiles extracted from two LIDAR Coastal National Elevation Database (CoNED) DEMs (spatial resolution: 0.5m), acquired on 2008 and 2012, and (4) spatial and temporal correlation of the detected changes in elevation with relevant data sets (e.g., lake levels, precipitation, groundwater levels) in search of causal effects.

  3. Using recurrent neural network models for early detection of heart failure onset.

    Science.gov (United States)

    Choi, Edward; Schuetz, Andy; Stewart, Walter F; Sun, Jimeng

    2017-03-01

    We explored whether use of deep learning to model temporal relations among events in electronic health records (EHRs) would improve model performance in predicting initial diagnosis of heart failure (HF) compared to conventional methods that ignore temporality. Data were from a health system's EHR on 3884 incident HF cases and 28 903 controls, identified as primary care patients, between May 16, 2000, and May 23, 2013. Recurrent neural network (RNN) models using gated recurrent units (GRUs) were adapted to detect relations among time-stamped events (eg, disease diagnosis, medication orders, procedure orders, etc.) with a 12- to 18-month observation window of cases and controls. Model performance metrics were compared to regularized logistic regression, neural network, support vector machine, and K-nearest neighbor classifier approaches. Using a 12-month observation window, the area under the curve (AUC) for the RNN model was 0.777, compared to AUCs for logistic regression (0.747), multilayer perceptron (MLP) with 1 hidden layer (0.765), support vector machine (SVM) (0.743), and K-nearest neighbor (KNN) (0.730). When using an 18-month observation window, the AUC for the RNN model increased to 0.883 and was significantly higher than the 0.834 AUC for the best of the baseline methods (MLP). Deep learning models adapted to leverage temporal relations appear to improve performance of models for detection of incident heart failure with a short observation window of 12-18 months. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  4. Monitoring of operational reliability of safety-related I and C subsystems at the Dukovany NPP

    International Nuclear Information System (INIS)

    Fuchs, P.; Sagl, P.; Zlamal, P.

    2007-01-01

    First, the situation existing in the data base in 1999, i.e. before the monitoring and the operational reliability monitoring concept were introduced, is highlighted. The technique of data processing is described with focus on the assessment of the relevancy of the records, component failure rate monitoring, estimation of basic statistical parameters, evaluation of the feasibility of component failure (or failure latency) detection, assessment of the mean time to repair, FMEA of the basic components (relays end measuring chains) to establish spurious signals and dangerous failure ratio. The reliability assessment of the system functions is based on structural reliability calculations (common cause failures not included). The outcomes from the operational reliability monitoring are presented in the form of a representative set of data, graphic charts and results of system function reliability assessment. Prospects for upgrading the I and C operational reliability monitoring system to the benefit of NPP Dukovany operating economy (life cycle costs evaluation, spare parts planning, RCM application) are outlined. (author)

  5. A method for reduction of Acoustic Emission (AE) data with application in machine failure detection and diagnosis

    Science.gov (United States)

    Vicuña, Cristián Molina; Höweler, Christoph

    2017-12-01

    The use of AE in machine failure diagnosis has increased over the last years. Most AE-based failure diagnosis strategies use digital signal processing and thus require the sampling of AE signals. High sampling rates are required for this purpose (e.g. 2 MHz or higher), leading to streams of large amounts of data. This situation is aggravated if fine resolution and/or multiple sensors are required. These facts combine to produce bulky data, typically in the range of GBytes, for which sufficient storage space and efficient signal processing algorithms are required. This situation probably explains why, in practice, AE-based methods consist mostly in the calculation of scalar quantities such as RMS and Kurtosis, and the analysis of their evolution in time. While the scalar-based approach offers the advantage of maximum data reduction; it has the disadvantage that most part of the information contained in the raw AE signal is lost unrecoverably. This work presents a method offering large data reduction, while keeping the most important information conveyed by the raw AE signal, useful for failure detection and diagnosis. The proposed method consist in the construction of a synthetic, unevenly sampled signal which envelopes the AE bursts present on the raw AE signal in a triangular shape. The constructed signal - which we call TriSignal - also permits the estimation of most scalar quantities typically used for failure detection. But more importantly, it contains the information of the time of occurrence of the bursts, which is key for failure diagnosis. Lomb-Scargle normalized periodogram is used to construct the TriSignal spectrum, which reveals the frequency content of the TriSignal and provides the same information as the classic AE envelope. The paper includes application examples in planetary gearbox and low-speed rolling element bearing.

  6. Clinical significance of detection of plasma natriuretic peptide in the diagnosis of patients with heart failure

    International Nuclear Information System (INIS)

    Song Chunli; Liu Haihong; Zhao Ning; Li Jie; Huang Jianmin

    2009-01-01

    To explore the clinical significance of plasma natriuretic peptide in the diagnosis of patients with heart failure (HF), the plasma atrial natriuretic peptide (ANP), brain natriuretic peptide (BNP), NT-pro brain natriuretic peptide (NT-proBNP) levels in 129 patients with heart failure and 30 healthy controls were detected by RIA and ELISA. The results showed that the plasma ANP, BNP, NT-proBNP levels in patients with heart failure were significantly higher than the healthy controls. As the cardiac function deteriorated from NYHA I to IV, the BNP and NT-proBNP levels increased consecutively with significant differences from each other. There was a negative correlation between the plasma ANP and NT-proBNP levels and LVEF. The determination of plasma ANP, BNP and NT-proBNP levels in patients with HF were helpful to the study of the severity and diagnosis of disease. (authors)

  7. Survey of operating experience from LERs to identify aging trends

    International Nuclear Information System (INIS)

    Murphy, G.A.

    1985-01-01

    The results of a study using the Oak Ridge National Laboratory's Nuclear Operations Analysis Center computer files of operating experience reports [licensee event reports (LERs), abnormal occurrences, etc.] are summarized in this study, specific time-related degradation mechanisms are identified as possible causes of a reportable occurrence. Data collected on domestic commercial nuclear power plants covering 1969 to 1982 yielded over 5800 events attributable to possible age related failures. Of these events, 2795 were attributable to instrument drift and are addressed separately in the report. The remaining events (3098) were reviewed, and data were collected for each event, which identified the specific system, component, and subpart: the information included the age-related mechanism, severity of the failure, and method of detection of the failure. About two-thirds of the failures were judged to be degraded, with one-third listed as catastrophic

  8. Sensitivity of probability-of-failure estimates with respect to probability of detection curve parameters

    Energy Technology Data Exchange (ETDEWEB)

    Garza, J. [University of Texas at San Antonio, Mechanical Engineering, 1 UTSA circle, EB 3.04.50, San Antonio, TX 78249 (United States); Millwater, H., E-mail: harry.millwater@utsa.edu [University of Texas at San Antonio, Mechanical Engineering, 1 UTSA circle, EB 3.04.50, San Antonio, TX 78249 (United States)

    2012-04-15

    A methodology has been developed and demonstrated that can be used to compute the sensitivity of the probability-of-failure (POF) with respect to the parameters of inspection processes that are simulated using probability of detection (POD) curves. The formulation is such that the probabilistic sensitivities can be obtained at negligible cost using sampling methods by reusing the samples used to compute the POF. As a result, the methodology can be implemented for negligible cost in a post-processing non-intrusive manner thereby facilitating implementation with existing or commercial codes. The formulation is generic and not limited to any specific random variables, fracture mechanics formulation, or any specific POD curve as long as the POD is modeled parametrically. Sensitivity estimates for the cases of different POD curves at multiple inspections, and the same POD curves at multiple inspections have been derived. Several numerical examples are presented and show excellent agreement with finite difference estimates with significant computational savings. - Highlights: Black-Right-Pointing-Pointer Sensitivity of the probability-of-failure with respect to the probability-of-detection curve. Black-Right-Pointing-Pointer The sensitivities are computed with negligible cost using Monte Carlo sampling. Black-Right-Pointing-Pointer The change in the POF due to a change in the POD curve parameters can be easily estimated.

  9. Sensitivity of probability-of-failure estimates with respect to probability of detection curve parameters

    International Nuclear Information System (INIS)

    Garza, J.; Millwater, H.

    2012-01-01

    A methodology has been developed and demonstrated that can be used to compute the sensitivity of the probability-of-failure (POF) with respect to the parameters of inspection processes that are simulated using probability of detection (POD) curves. The formulation is such that the probabilistic sensitivities can be obtained at negligible cost using sampling methods by reusing the samples used to compute the POF. As a result, the methodology can be implemented for negligible cost in a post-processing non-intrusive manner thereby facilitating implementation with existing or commercial codes. The formulation is generic and not limited to any specific random variables, fracture mechanics formulation, or any specific POD curve as long as the POD is modeled parametrically. Sensitivity estimates for the cases of different POD curves at multiple inspections, and the same POD curves at multiple inspections have been derived. Several numerical examples are presented and show excellent agreement with finite difference estimates with significant computational savings. - Highlights: ► Sensitivity of the probability-of-failure with respect to the probability-of-detection curve. ►The sensitivities are computed with negligible cost using Monte Carlo sampling. ► The change in the POF due to a change in the POD curve parameters can be easily estimated.

  10. Failure Analysis

    International Nuclear Information System (INIS)

    Iorio, A.F.; Crespi, J.C.

    1987-01-01

    After ten years of operation at the Atucha I Nuclear Power Station a gear belonging to a pressurized heavy water reactor refuelling machine, failed. The gear box was used to operate the inlet-outlet heavy-water valve of the machine. Visual examination of the gear device showed an absence of lubricant and that several gear teeth were broken at the root. Motion was transmitted with a speed-reducing device with controlled adjustable times in order to produce a proper fitness of the valve closure. The aim of this paper is to discuss the results of the gear failure analysis in order to recommend the proper solution to prevent further failures. (Author)

  11. Analysis for Involvement of TPP Operating in Accordance with Heating Schedule to Passing Through Failures of Electric Load Schedules

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2013-01-01

    Full Text Available The paper describes technical and economic evaluation of various methods pertaining to passing through failures of electric load at TPP which is operating in accordance with heating schedule.

  12. WWER expert system for fuel failure analysis using the RTOP-CA code

    International Nuclear Information System (INIS)

    Likhanskii, V.; Evdokimov, I.; Sorokin, A.; Khromov, A.; Kanukova, V.; Apollonova, O.; Ugryumov, A.

    2008-01-01

    The computer expert system for fuel failure analysis of WWER during operation is presented. The diagnostics is based on the measurement of specific activity of reference nuclides in reactor primary coolant and application of a computer code for the data interpretation. The data analysis includes an evaluation of tramp uranium mass in reactor core, detection of failures by iodine and caesium spikes, evaluation of burnup of defective fuel. Evaluation of defective fuel burnup was carried out by applying the relation of caesium nuclides activity in spikes and relations of activities of gaseous fission products for steady state operational conditions. The method of burnup evaluation of defective fuel by use of fission gas activity is presented in details. The neural-network analysis is performed for determination of failed fuel rod number and defect size. Results of the expert system application are illustrated for several fuel campaigns on operating WWER NPPs. (authors)

  13. Small leak detection requirements for SNR-300 steam generator operation

    International Nuclear Information System (INIS)

    Dumm, K.

    1975-01-01

    The leak detection philosophy of the SNR-300 steam generators is described. Due to operational demands small leaks have already to be detectable at a stage where secondary tube damage has not yet occurred. The requirements on a leak detection instrument are developed and the instrument itself is described. (author)

  14. Small leak detection requirements for SNR-300 steam generator operation

    Energy Technology Data Exchange (ETDEWEB)

    Dumm, K

    1975-07-01

    The leak detection philosophy of the SNR-300 steam generators is described. Due to operational demands small leaks have already to be detectable at a stage where secondary tube damage has not yet occurred. The requirements on a leak detection instrument are developed and the instrument itself is described. (author)

  15. Computer monitoring of the RB reactor operation

    International Nuclear Information System (INIS)

    Milovanovic, S.; Pesic, M.; Milovanovic, T.

    1998-01-01

    Personal computer based acquisition system designed for monitoring of operation of the RB experimental reactor in the Institute of Nuclear Sciences 'Vinca' (former 'Boris Kidric') and experiences acquired during its use are shown in this paper. The monitoring covers generally all nuclear aspects of the reactor operation (start-up, nominal power operation, power changing, shut down and maintenance), but the emphasis is put on: real time (especially fast changing) reactivity measurement; supervising time dependence of the safety rods positions during shut down, and detection of position inaccuracy or failure operation of safety/control rods during the reactor operation or maintenance. (author)

  16. A model-based prognostic approach to predict interconnect failure using impedance analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Dae Il; Yoon, Jeong Ah [Dept. of System Design and Control Engineering. Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2016-10-15

    The reliability of electronic assemblies is largely affected by the health of interconnects, such as solder joints, which provide mechanical, electrical and thermal connections between circuit components. During field lifecycle conditions, interconnects are often subjected to a DC open circuit, one of the most common interconnect failure modes, due to cracking. An interconnect damaged by cracking is sometimes extremely hard to detect when it is a part of a daisy-chain structure, neighboring with other healthy interconnects that have not yet cracked. This cracked interconnect may seem to provide a good electrical contact due to the compressive load applied by the neighboring healthy interconnects, but it can cause the occasional loss of electrical continuity under operational and environmental loading conditions in field applications. Thus, cracked interconnects can lead to the intermittent failure of electronic assemblies and eventually to permanent failure of the product or the system. This paper introduces a model-based prognostic approach to quantitatively detect and predict interconnect failure using impedance analysis and particle filtering. Impedance analysis was previously reported as a sensitive means of detecting incipient changes at the surface of interconnects, such as cracking, based on the continuous monitoring of RF impedance. To predict the time to failure, particle filtering was used as a prognostic approach using the Paris model to address the fatigue crack growth. To validate this approach, mechanical fatigue tests were conducted with continuous monitoring of RF impedance while degrading the solder joints under test due to fatigue cracking. The test results showed the RF impedance consistently increased as the solder joints were degraded due to the growth of cracks, and particle filtering predicted the time to failure of the interconnects similarly to their actual timesto- failure based on the early sensitivity of RF impedance.

  17. A Novel Thermal-Mechanical Detection System for Reactor Pressure Vessel Bottom Failure Monitoring in Severe Accidents

    International Nuclear Information System (INIS)

    Bi, Daowei; Bu, Jiangtao; Xu, Dongling

    2013-06-01

    Following the Fukushima Daiichi nuclear accident in Japan, there is an increased need of enhanced capabilities for severe accident management (SAM) program. Among others, a reliable method for detecting reactor pressure vessel (RPV) bottom failure has been evaluated as imperative by many utility owners. Though radiation and/or temperature measurement are potential solutions by tradition, there are some limitations for them to function desirably in such severe accident as that in Japan. To provide reliable information for assessment of accident progress in SAM program, in this paper we propose a novel thermal-mechanical detection system (TMDS) for RPV bottom failure monitoring in severe accidents. The main components of TMDS include thermally sensitive element, metallic cables, tension controlled switch and main control room annunciation device. With TMDS installed, there shall be a reliable means of keeping SAM decision-makers informed whether the RPV bottom has indeed failed. Such assurance definitely guarantees enhancement of severe accident management performance and significantly improve nuclear safety and thus protect the society and people. (authors)

  18. Signal detection theory, the exclusion failure paradigm and weak consciousness--evidence for the access/phenomenal distinction?

    Science.gov (United States)

    Irvine, Elizabeth

    2009-06-01

    Block [Block, N. (2005). Two neural correlates of consciousness. Trends in Cognitive Science, 9, 46-52] and Snodgrass (2006) claim that a signal detection theory (SDT) analysis of qualitative difference paradigms, in particular the exclusion failure paradigm, reveals cases of phenomenal consciousness without access consciousness. This claim is unwarranted on several grounds. First, partial cognitive access rather than a total lack of cognitive access can account for exclusion failure results. Second, Snodgrass's Objective Threshold/Strategic (OT/S) model of perception relies on a problematic 'enable' approach to perception that denies the possibility of intentional control of unconscious perception and any effect of following different task instructions on the presence/absence of phenomenal consciousness. Many of Block's purported examples of phenomenal consciousness without cognitive access also rely on this problematic approach. Third, qualitative difference paradigms may index only a subset of access consciousness. Thus, qualitative difference paradigms like exclusion failure cannot be used to isolate phenomenal consciousness, any attempt to do so still faces serious methodological problems.

  19. Unavailability of repairable components with failures detectable upon demand: Remarks on a work of Caldarola

    International Nuclear Information System (INIS)

    Souza Borges, W. de; Silva Pagetti, P. da

    1987-01-01

    In this paper an exact expression has been obtained for the asymptotic mean unavailability in time domain of components with failures detected upon demand. The model is more general than those proposed in the literature since it allows the use of general distributions for component life times, repair times and inter-demand times. Expressions for the special case of exponential life times have also been derived. (orig.)

  20. Direct ultimate disposal of spent fuel. Simulation of shaft transport. Tests for removing operating failures (TA 6)

    International Nuclear Information System (INIS)

    Filbert, W.; Heda, M.; Neydek, J.

    1994-03-01

    Probable operating failures were analysed and appropriate means for recovery were planned. Based on the analysis of probable failures, three major countermeasures were defined and planned in detail for subsequent demonstration tests: recovery of a fully functioning plateau car, recovery of a plateau car that got stuck, and recovery of a plateau car that ran off the rails. All failures investigated can be repaired by one countermeasure, or a combination of the measures provided for. Trained personnel will be able to restore full service of a loaded POLLUX plateau car that ran off the track and is damaged within approx. 50 minutes. Dose calculations on a conservative basis indicate personal doses resulting from recovery and repair work to be between 200 μSv (20 mrem) and 52 μSv (5.2 mrem). The collective dose is calculated to be approx. 250 μSv (25 mrem). (orig./HP) [de

  1. Failure probability analyses for PWSCC in Ni-based alloy welds

    International Nuclear Information System (INIS)

    Udagawa, Makoto; Katsuyama, Jinya; Onizawa, Kunio; Li, Yinsheng

    2015-01-01

    A number of cracks due to primary water stress corrosion cracking (PWSCC) in pressurized water reactors and Ni-based alloy stress corrosion cracking (NiSCC) in boiling water reactors have been detected around Ni-based alloy welds. The causes of crack initiation and growth due to stress corrosion cracking include weld residual stress, operating stress, the materials, and the environment. We have developed the analysis code PASCAL-NP for calculating the failure probability and assessment of the structural integrity of cracked components on the basis of probabilistic fracture mechanics (PFM) considering PWSCC and NiSCC. This PFM analysis code has functions for calculating the incubation time of PWSCC and NiSCC crack initiation, evaluation of crack growth behavior considering certain crack location and orientation patterns, and evaluation of failure behavior near Ni-based alloy welds due to PWSCC and NiSCC in a probabilistic manner. Herein, actual plants affected by PWSCC have been analyzed using PASCAL-NP. Failure probabilities calculated by PASCAL-NP are in reasonable agreement with the detection data. Furthermore, useful knowledge related to leakage due to PWSCC was obtained through parametric studies using this code

  2. Cognitive models and computer aids for nuclear plant control room operators

    International Nuclear Information System (INIS)

    Sheridan, T.B.

    1982-01-01

    This paper reviews what is usually meant by a cognitive model of a control room operator in a nuclear power plant. It emphasizes the idea of internal (that is, mental) representation of external events and the use of such representation for the cognitive steps of attending, recognizing or learning, assessing and deciding. As computers play an increasingly important role in nuclear power plants, especially as cognitive aids to human supervisors of highly automated control systems, it is important that the software and computer interface characteristics be compatible with the operator's internal model. Specific examples discussed in this paper are in the monitoring and prediction of the plant state and in the detection and diagnosis of failures. Current trends in SPDS (safety parameter display system) and failure detection/location systems will be discussed in this regard

  3. Lessons learned from fatique failures in major FWR components

    International Nuclear Information System (INIS)

    Ware, A.G.; Shah, V.N.

    1992-01-01

    This paper evaluates the field fatigue failure experience and describes the lessons learned that can be employed in managing fatigue damage at the sites of these failures and at other susceptible sites. Fatigue damage has resulted in cracks on the inside surfaces of vessels and piping, and in some cases, through-wall cracks resulting in coolant leakage. All of the fatigue failures resulted from conditions or stressors that were not accounted for in the original design analyses. In some cases, it has proven difficult to discover fatigue cracks using conventional inservice inspection methods; several cracks were detected because of leakage. Supplementary monitoring and inspection techniques such as fatigue monitoring, acoustic emission monitoring, and time-of-flight-diffraction ultrasonic testing can be used to assist in identifying susceptible sites, estimating crack growth, and sizing existing fatigue cracks. It is important to identify the root cause of failures because once the stressors and degradation mechanisms are known, changes in operating procedures and designs can be implemented to mitigate future fatigue damage

  4. Operation and technology development of the radioactive xenon and krypton detection equipment

    International Nuclear Information System (INIS)

    Lee, Wanno; Choi, Sangdo; Ji, Youngyong; Lim, Jong Myoung; Cho, Young Hyun; Kang, Han Beul; Lee, Hoon; Kang, Moon Ja; Choi, Kun Sik

    2013-03-01

    Operation and technology development of the radioactive xenon and krypton detection equipment - Advancement, independence of operation technology for BfS-IAR system(the simultaneous analysis of xenon and krypton) installed after North Korea nuclear tests in 2006 and establishment of background base-line for xenon and krypton radioactivity. - Enhanced detection and analysis capabilities for neighborhood nuclear activities through advanced research of noble gas detection technology. Results of the Project · The operation of xenon and krypton analysis system (BfS-IAR) · Operation of fixed adsorption system. · Operation of portable adsorption system · Exercise of emergency response and proficiency test with SAUNA. · Measurement of noble gas background at specific region in Korea. - Radioxenon levels at Dongdu Cheon is approximately 1.6 mBq/m 3 · Development of automation filling system for absorber cooling

  5. On-line process failure diagnosis: The necessity and a comparative review of the methodologies

    International Nuclear Information System (INIS)

    Kim, I.S.

    1991-01-01

    Three basic approaches to process failure management are defined and discussed to elucidate the role of diagnosis in the operation of nuclear power plants. The rationale for the necessity of diagnosis is given from various perspectives. A comparative review of some representative diagnostic methodologies is presented and their shortcomings are discussed. Based on the insights from the review, the desirable characteristics from the review, the desirable characteristics of advanced diagnostic methodologies are derived from the viewpoints of failure detection, diagnosis, and correction. 11 refs

  6. Detection circuit of solenoid valve operation and control rod drive mechanism utilizing the circuit

    International Nuclear Information System (INIS)

    Ono, Takehiko.

    1976-01-01

    Object: To detect the operation of a plunger and detect opening and closing operations of a solenoid valve driving device due to change in impedance of a coil for driving the solenoid valve to judge normality and abnormality of the solenoid valve, thereby increasing reliance and safety of drive and control apparatus of control rods. Structure: An arrangement comprises a drive and operation detector section wherein the operation of a solenoid driving device for controlling power supply to a coil for driving the solenoid valve to control opening and closing of the solenoid valve, and a plunger operation detector section for detecting change in impedance of the drive coil to detect that the plunger of the solenoid valve is either in the opening direction or closing direction, whereby a predetermined low voltage such as not to activate the solenoid valve even when the solenoid valve is open or closed is applied to detect a current flowing into the coil at that time, thus detecting an operating state of the plunger. (Yoshino, Y.)

  7. Safety related considerations for operation with defected elements in EBR-II

    International Nuclear Information System (INIS)

    Fryer, R.M.; Sackett, J.I.; Lambert, J.D.B.

    1976-01-01

    Traditionally, EBR-II has employed the 'shutdown and remove' philosophy when breached fuel elements are encountered. This mode of operation maintained in-plant inventories of fission products at low levels and allowed certain fission product detection systems to be employed as automatic plant shutdown devices. Information from fuel failure propagation studies and fast reactor operation indicates that shutdown under these conditions is unwarranted. Analytical studies, as well as fast reactor experience, further indicate that failure propagation, if it occurs at all, will not cross adjacent subassembly boundaries. Therefore, the 'shutdown and remove' philosophy can be liberalized to allow the demonstration of safety during a run-beyond-clad-breach mode of operation. This mode of operation is essential to the demonstration of the economics of commercial LMFBR systems

  8. Dependent failures of diesel generators

    International Nuclear Information System (INIS)

    Mankamo, T.; Pulkkinen, U.

    1982-01-01

    This survey of dependent failures (common-cause failures) is based on the data of diesel generator failures in U. S. nuclear power plants as reported in Licensee Event Reports. Failures were classified into random and potentially dependent failures. All failures due to design errors, manufacturing or installation errors, maintenance errors, or deviations in the operational environment were classified as potentially dependent failures.The statistical dependence between failures was estimated from the relative portion of multiple failures. Results confirm the earlier view of the significance of statistical dependence, a strong dependence on the age of the diesel generator was found in each failure class excluding random failures and maintenance errors, which had a nearly constant frequency independent of diesel generator age

  9. Detection of Taenia solium taeniasis coproantigen is an early indicator of treatment failure for taeniasis.

    Science.gov (United States)

    Bustos, Javier A; Rodriguez, Silvia; Jimenez, Juan A; Moyano, Luz M; Castillo, Yesenia; Ayvar, Viterbo; Allan, James C; Craig, Philip S; Gonzalez, Armando E; Gilman, Robert H; Tsang, Victor C W; Garcia, Hector H

    2012-04-01

    Taenia solium causes taeniasis and cysticercosis, a zoonotic complex associated with a significant burden of epilepsy in most countries. Reliable diagnosis and efficacious treatment of taeniasis are needed for disease control. Currently, cure can be confirmed only after a period of at least 1 month, by negative stool microscopy. This study assessed the performance of detection by a coproantigen enzyme-linked immunosorbent assay (CoAg-ELISA) for the early evaluation of the efficacy of antiparasitic treatment of human T. solium taeniasis. We followed 69 tapeworm carriers who received niclosamide as standard treatment. Stool samples were collected on days 1, 3, 7, 15, 30, and 90 after treatment and were processed by microscopy and CoAg-ELISA. The efficacy of niclosamide was 77.9% (53/68). Thirteen patients received a second course of treatment and completed the follow-up. CoAg-ELISA was therefore evaluated for a total of 81 cases (68 treatments, 13 retreatments). In successful treatments (n = 64), the proportion of patients who became negative by CoAg-ELISA was 62.5% after 3 days, 89.1% after 7 days, 96.9% after 15 days, and 100% after 30 days. In treatment failures (n = 17), the CoAg-ELISA result was positive for 70.6% of patients after 3 days, 94.1% after 7 days, and 100% after 15 and 30 days. Only 2 of 17 samples in cases of treatment failure became positive by microscopy by day 30. The presence of one scolex, but not multiple scolices, in posttreatment stools was strongly associated with cure (odds ratio [OR], 52.5; P taeniasis. Early assessment at day 15 would detect treatment failure before patients become infective.

  10. The likelihood of failures in the operation of the lifting mechanism electrical hook bridge crane

    Directory of Open Access Journals (Sweden)

    Ritenman I.L.

    2017-09-01

    Full Text Available Given the application of the methods of analysis of types and consequences of failures (FMEA analysis to assess the technical risk of occurrence of emergency situations during the operation of the lifting mechanism electrical hook bridge crane. The technique allows to identify the limiting elements and to determine the significance of effects in the design of the lifting mechanism, to develop measures to reduce the risk of the occurrence of an emergency.

  11. Automatic detection of animals in mowing operations using thermal cameras.

    Science.gov (United States)

    Steen, Kim Arild; Villa-Henriksen, Andrés; Therkildsen, Ole Roland; Green, Ole

    2012-01-01

    During the last decades, high-efficiency farming equipment has been developed in the agricultural sector. This has also included efficiency improvement of moving techniques, which include increased working speeds and widths. Therefore, the risk of wild animals being accidentally injured or killed during routine farming operations has increased dramatically over the years. In particular, the nests of ground nesting bird species like grey partridge (Perdix perdix) or pheasant (Phasianus colchicus) are vulnerable to farming operations in their breeding habitat, whereas in mammals, the natural instinct of e.g., leverets of brown hare (Lepus europaeus) and fawns of roe deer (Capreolus capreolus) to lay low and still in the vegetation to avoid predators increase their risk of being killed or injured in farming operations. Various methods and approaches have been used to reduce wildlife mortality resulting from farming operations. However, since wildlife-friendly farming often results in lower efficiency, attempts have been made to develop automatic systems capable of detecting wild animals in the crop. Here we assessed the suitability of thermal imaging in combination with digital image processing to automatically detect a chicken (Gallus domesticus) and a rabbit (Oryctolagus cuniculus) in a grassland habitat. Throughout the different test scenarios, our study animals were detected with a high precision, although the most dense grass cover reduced the detection rate. We conclude that thermal imaging and digital imaging processing may be an important tool for the improvement of wildlife-friendly farming practices in the future.

  12. Data-Driven Anomaly Detection Performance for the Ares I-X Ground Diagnostic Prototype

    Science.gov (United States)

    Martin, Rodney A.; Schwabacher, Mark A.; Matthews, Bryan L.

    2010-01-01

    In this paper, we will assess the performance of a data-driven anomaly detection algorithm, the Inductive Monitoring System (IMS), which can be used to detect simulated Thrust Vector Control (TVC) system failures. However, the ability of IMS to detect these failures in a true operational setting may be related to the realistic nature of how they are simulated. As such, we will investigate both a low fidelity and high fidelity approach to simulating such failures, with the latter based upon the underlying physics. Furthermore, the ability of IMS to detect anomalies that were previously unknown and not previously simulated will be studied in earnest, as well as apparent deficiencies or misapplications that result from using the data-driven paradigm. Our conclusions indicate that robust detection performance of simulated failures using IMS is not appreciably affected by the use of a high fidelity simulation. However, we have found that the inclusion of a data-driven algorithm such as IMS into a suite of deployable health management technologies does add significant value.

  13. Low-cost failure sensor design and development for water pipeline distribution systems.

    Science.gov (United States)

    Khan, K; Widdop, P D; Day, A J; Wood, A S; Mounce, S R; Machell, J

    2002-01-01

    This paper describes the design and development of a new sensor which is low cost to manufacture and install and is reliable in operation with sufficient accuracy, resolution and repeatability for use in newly developed systems for pipeline monitoring and leakage detection. To provide an appropriate signal, the concept of a "failure" sensor is introduced, in which the output is not necessarily proportional to the input, but is unmistakably affected when an unusual event occurs. The design of this failure sensor is based on the water opacity which can be indicative of an unusual event in a water distribution network. The laboratory work and field trials necessary to design and prove out this type of failure sensor are described here. It is concluded that a low-cost failure sensor of this type has good potential for use in a comprehensive water monitoring and management system based on Artificial Neural Networks (ANN).

  14. Multiple-failure signal validation in nuclear power plants using artificial neural networks

    International Nuclear Information System (INIS)

    Fantoni, P.F.; Mazzola, A.

    1996-01-01

    The possibility of using a neural network to validate process signals during normal and abnormal plant conditions is explored. In boiling water reactor plants, signal validation is used to generate reliable thermal limits calculation and to supply reliable inputs to other computerized systems that support the operator during accident scenarios. The way that autoassociative neural networks can promptly detect faulty process signal measurements and produce a best estimate of the actual process values even in multifailure situations is shown. A method was developed to train the network for multiple sensor-failure detection, based on a random failure simulation algorithm. Noise was artificially added to the input to evaluate the network's ability to respond in a very low signal-to-noise ratio environment. Training and test data sets were simulated by the real-time transient simulator code APROS

  15. Detection of resistance mutations and CD4 slopes in individuals experiencing sustained virological failure

    DEFF Research Database (Denmark)

    Schultze, Anna; Paredes, Roger; Sabin, Caroline

    2014-01-01

    during the episode were included. Mutations were identified using the IAS-US (2013) list, and were presumed to be present from detection until the end of an episode. Multivariable linear mixed models with a random intercept and slope adjusted for age, baseline CD4 count, hepatitis C, drug type, RNA (log...... mutations on CD4 slopes in patients undergoing episodes of viral failure. MATERIALS AND METHODS: Patients from the EuroSIDA and UK CHIC cohorts undergoing at least one episode of virological failure (>3 consecutive RNA measurements >500 on ART) with at least three CD4 measurements and a resistance test......-scale), risk group and subtype were used to estimate CD4 slopes. Individual mutations with a population prevalence of >10% were tested for their effect on the CD4 slope. RESULTS: A total of 2731 patients experiencing a median of 1 (range 1-4) episodes were included in this analysis. The prevalence of any...

  16. Regulatory experience with fuel failures in Switzerland

    International Nuclear Information System (INIS)

    Adam, L.

    2015-01-01

    In this paper the main ENSI activities like: supervision of reactor and radiation safety and security; supervision of safety of transports of nuclear materials and assess the safety of proposed solutions for the geological disposal are listed. Recent events concerning the reactor core, common causes for fuel failures, findings during inspections and potential root cause for fuel failures are discussed. Management of fuel failures, started from reporting of the event – evaluation of the need of imminent action; identification of the fuel element if possible till evaluation by the plant and fuel vendor and allowance by ENSI for repair of the fuel element and definition of measures (short and long term) are also presented. The following Conclusions by ENSI about status of fuel failures are made: 1) Number of fuel failures was reduced regardless more economic operation in all plants; 2) Old PWR and BWR reactors achieved 15 to 29 years operation without leakers, but two minor fuel damage during fuel handling appeared; 3) Newer plants are not better in achieving operation without leakers than older plants; 4) Technical improvements at fuel elements parallel to changes in operation strategy and improvements in manufacturing quality but single effects difficult to judge. The issues about how to implement “Zero Failure Rates” in regulations and how to achieve “Zero Failure Rates” as well as some future measures by ENSI are discussed

  17. Standard guide for corrosion-related failure analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers key issues to be considered when examining metallic failures when corrosion is suspected as either a major or minor causative factor. 1.2 Corrosion-related failures could include one or more of the following: change in surface appearance (for example, tarnish, rust, color change), pin hole leak, catastrophic structural failure (for example, collapse, explosive rupture, implosive rupture, cracking), weld failure, loss of electrical continuity, and loss of functionality (for example, seizure, galling, spalling, swelling). 1.3 Issues covered include overall failure site conditions, operating conditions at the time of failure, history of equipment and its operation, corrosion product sampling, environmental sampling, metallurgical and electrochemical factors, morphology (mode) or failure, and by considering the preceding, deducing the cause(s) of corrosion failure. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibili...

  18. Operating Experience Insights into Pipe Failures for Electro-Hydraulic Control and Instrument Air Systems in Nuclear Power Plant. A Topical Report from the Component Operational Experience, Degradation and Ageing Programme

    International Nuclear Information System (INIS)

    2015-01-01

    Structural integrity of piping systems is important for plant safety and operability. In recognition of this, information on degradation and failure of piping components and systems is collected and evaluated by regulatory agencies, international organisations (e.g. OECD/NEA and IAEA) and industry organisations worldwide to provide systematic feedback for example to reactor regulation and research and development programmes associated with non-destructive examination (NDE) technology, in-service inspection (ISI) programmes, leak-before-break evaluations, risk-informed ISI, and probabilistic safety assessment (PSA) applications involving passive component reliability. Several OECD member countries have agreed to establish the OECD/NEA 'Component Operational Experience, Degradation and Ageing Programme' (CODAP) to encourage multilateral co-operation in the collection and analysis of data relating to degradation and failure of metallic piping and non-piping metallic passive components in commercial nuclear power plants. The scope of the data collection includes service-induced wall thinning, part through-wall cracks, through-wall cracks with and without active leakage, and instances of significant degradation of metallic passive components, including piping pressure boundary integrity. The OECD/NEA Committee on the Safety of Nuclear Installations (CSNI) acts as an umbrella committee of the Project. CODAP is the continuation of the 2002-2011 'OECD/NEA Pipe Failure Data Exchange Project' (OPDE) and the Stress Corrosion Cracking Working Group of the 2006-2010 'OECD/NEA Stress Corrosion Cracking and Cable Ageing Project' (SCAP). OPDE was formally launched in May 2002. Upon completion of the third term (May 2011), the OPDE project was officially closed to be succeeded by CODAP. SCAP was enabled by a voluntary contribution from Japan. It was formally launched in June 2006 and officially closed with an international workshop held in Tokyo in May

  19. Material failures observed in Doublet III neutral beamlines

    International Nuclear Information System (INIS)

    Bailey, E.W.; Colleraine, A.; Doll, D.; Grunloh, H.; Kim, J.; Langhorn, A.; Thurgood, B.

    1983-12-01

    The Doublet III neutral beam injectors consist of three separable spools two meters in diameter by four meters long overall when assembled. Contained within these spools are the neutralizers, ion dumps, deflecting magnet, calorimeter dumps, cryogenic panels and beam scraping collimators 3,7. To date three beamlines are in operation on Doublet III, and the beams have accumulated operating time of approximately 32 months, with the oldest having been in operation for 18 months. During this time operation of DIII with the neutral beam sources has demonstrated the following: 7.8 MW injected neutrals from three beamlines (6 sources), high β (4.5%), and non-circular plasma shape. The sources have also exhibited a very reliable injected shot history 4, 5, 6, 8. Material failures encountered during the operation of DIII N.B. injectors and the solutions to these failures are described. Failures include cracking of the neutralizer exit collimator due to heating cycles, failure of cyropanel support rods due to cooling cycles, failure of the sliding drive of the moveable calorimeter due to friction

  20. [Development of operation patient security detection system].

    Science.gov (United States)

    Geng, Shu-Qin; Tao, Ren-Hai; Zhao, Chao; Wei, Qun

    2008-11-01

    This paper describes a patient security detection system developed with two dimensional bar codes, wireless communication and removal storage technique. Based on the system, nurses and correlative personnel check code wait operation patient to prevent the defaults. The tests show the system is effective. Its objectivity and currency are more scientific and sophisticated than current traditional method in domestic hospital.

  1. Anomaly Detection for Next-Generation Space Launch Ground Operations

    Science.gov (United States)

    Spirkovska, Lilly; Iverson, David L.; Hall, David R.; Taylor, William M.; Patterson-Hine, Ann; Brown, Barbara; Ferrell, Bob A.; Waterman, Robert D.

    2010-01-01

    NASA is developing new capabilities that will enable future human exploration missions while reducing mission risk and cost. The Fault Detection, Isolation, and Recovery (FDIR) project aims to demonstrate the utility of integrated vehicle health management (IVHM) tools in the domain of ground support equipment (GSE) to be used for the next generation launch vehicles. In addition to demonstrating the utility of IVHM tools for GSE, FDIR aims to mature promising tools for use on future missions and document the level of effort - and hence cost - required to implement an application with each selected tool. One of the FDIR capabilities is anomaly detection, i.e., detecting off-nominal behavior. The tool we selected for this task uses a data-driven approach. Unlike rule-based and model-based systems that require manual extraction of system knowledge, data-driven systems take a radically different approach to reasoning. At the basic level, they start with data that represent nominal functioning of the system and automatically learn expected system behavior. The behavior is encoded in a knowledge base that represents "in-family" system operations. During real-time system monitoring or during post-flight analysis, incoming data is compared to that nominal system operating behavior knowledge base; a distance representing deviation from nominal is computed, providing a measure of how far "out of family" current behavior is. We describe the selected tool for FDIR anomaly detection - Inductive Monitoring System (IMS), how it fits into the FDIR architecture, the operations concept for the GSE anomaly monitoring, and some preliminary results of applying IMS to a Space Shuttle GSE anomaly.

  2. Automatic Detection of Animals in Mowing Operations Using Thermal Cameras

    Directory of Open Access Journals (Sweden)

    Ole Green

    2012-06-01

    Full Text Available During the last decades, high-efficiency farming equipment has been developed in the agricultural sector. This has also included efficiency improvement of moving techniques, which include increased working speeds and widths. Therefore, the risk of wild animals being accidentally injured or killed during routine farming operations has increased dramatically over the years. In particular, the nests of ground nesting bird species like grey partridge (Perdix perdix or pheasant (Phasianus colchicus are vulnerable to farming operations in their breeding habitat, whereas in mammals, the natural instinct of e.g., leverets of brown hare (Lepus europaeus and fawns of roe deer (Capreolus capreolus to lay low and still in the vegetation to avoid predators increase their risk of being killed or injured in farming operations. Various methods and approaches have been used to reduce wildlife mortality resulting from farming operations. However, since wildlife-friendly farming often results in lower efficiency, attempts have been made to develop automatic systems capable of detecting wild animals in the crop. Here we assessed the suitability of thermal imaging in combination with digital image processing to automatically detect a chicken (Gallus domesticus and a rabbit (Oryctolagus cuniculus in a grassland habitat. Throughout the different test scenarios, our study animals were detected with a high precision, although the most dense grass cover reduced the detection rate. We conclude that thermal imaging and digital imaging processing may be an important tool for the improvement of wildlife-friendly farming practices in the future.

  3. Component failure data base of TRIGA reactors

    International Nuclear Information System (INIS)

    Djuricic, M.

    2004-10-01

    This compilation provides failure data such as first criticality, component type description (reactor component, population, cumulative calendar time, cumulative operating time, demands, failure mode, failures, failure rate, failure probability) and specific information on each type of component of TRIGA Mark-II reactors in Austria, Bangladesh, Germany, Finland, Indonesia, Italy, Indonesia, Slovenia and Romania. (nevyjel)

  4. Role of failure-mechanism identification in accelerated testing

    Science.gov (United States)

    Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.

    1993-01-01

    Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

  5. Detection of Partial Demagnetization Fault in PMSMs Operating under Nonstationary Conditions

    DEFF Research Database (Denmark)

    Wang, Chao; Delgado Prieto, Miguel; Romeral, Luis

    2016-01-01

    Demagnetization fault detection of in-service Permanent Magnet Synchronous Machines (PMSMs) is a challenging task because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman F......Demagnetization fault detection of in-service Permanent Magnet Synchronous Machines (PMSMs) is a challenging task because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold......-Kalman Filter is proposed to detect the partial demagnetization fault in PMSMs running at nonstationary conditions. Amplitude of envelope of the fault characteristic orders is used as fault indictor. Experimental results verify the superiority of the proposed method on partial demagnetization online fault...... detection of PMSMs under various speed and load conditions....

  6. Detection of gaseous fission products in water - a method of monitoring fuel sheathing failures

    Energy Technology Data Exchange (ETDEWEB)

    Tunnicliffe, P. R.; Whittier, A. C.

    1959-05-15

    The gaseous activities stripped from samples of effluent coolant from the NRU fuel elements tested in the central thimble of the NRX reactor (NRU loop) and from the NRX main effluent have been investigated. The activities obtained from the NRU loop can be attributed to gaseous fission products only. Design data have been obtained for a 'Gaseous Fission Product Monitor' to be installed for use with the NRU reactor. It is expected that this monitor will have high sensitivity to activity indicative of an incipient fuel element sheath failure. No qualitative determination of the various gaseous activities obtained from the NRX effluent has been made. A strong component of 25 {+-}1 seconds half-life is not consistent with O-19. Limited information concerning sheath failures in NRX was obtained. Of six failures observed in parallel with the installed delayed neutron monitors, three of these gave pre-warnings and in each case the gaseous fission product monitor showed a substantially greater sensitivity. An experiment in which small samples of uranium, inserted into the NRX reactor, could be exposed at will to a stream of water showed the behaviour of the two types of monitors to be similar. However, a number of signals were detected only by the gaseous fission product monitor. These can be attributed to its sensitivity to relatively long lived fission products. (author)

  7. Image diagnosis of parathyroid glands in chronic renal failure

    International Nuclear Information System (INIS)

    Takagi, H.; Tominaga, Y.; Uchida, K.; Yamada, N.; Morimoto, T.; Yasue, M.

    1983-01-01

    Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with 201 TlCl and /sup 99m/TcO 4+ , and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment

  8. Most Probable Failures in LHC Magnets and Time Constants of their Effects on the Beam.

    CERN Document Server

    Gomez Alonso, Andres

    2006-01-01

    During the LHC operation, energies up to 360 MJ will be stored in each proton beam and over 10 GJ in the main electrical circuits. With such high energies, beam losses can quickly lead to important equipment damage. The Machine Protection Systems have been designed to provide reliable protection of the LHC through detection of the failures leading to beam losses and fast dumping of the beams. In order to determine the protection strategies, it is important to know the time constants of the failure effects on the beam. In this report, we give an estimation of the time constants of quenches and powering failures in LHC magnets. The most critical failures are powering failures in certain normal conducting circuits, leading to relevant effects on the beam in ~1 ms. The failures on super conducting magnets leading to fastest losses are quenches. In this case, the effects on the beam can be signficant ~10 ms after the quench occurs.

  9. A reliability program approach to operational safety

    International Nuclear Information System (INIS)

    Mueller, C.J.; Bezella, W.A.

    1985-01-01

    A Reliability Program (RP) model based on proven reliability techniques is being formulated for potential application in the nuclear power industry. Methods employed under NASA and military direction, commercial airline and related FAA programs were surveyed and a review of current nuclear risk-dominant issues conducted. The need for a reliability approach to address dependent system failures, operating and emergency procedures and human performance, and develop a plant-specific performance data base for safety decision making is demonstrated. Current research has concentrated on developing a Reliability Program approach for the operating phase of a nuclear plant's lifecycle. The approach incorporates performance monitoring and evaluation activities with dedicated tasks that integrate these activities with operation, surveillance, and maintenance of the plant. The detection, root-cause evaluation and before-the-fact correction of incipient or actual systems failures as a mechanism for maintaining plant safety is a major objective of the Reliability Program. (orig./HP)

  10. DC-to-AC inverter ratio failure detector

    Science.gov (United States)

    Ebersole, T. J.; Andrews, R. E.

    1975-01-01

    Failure detection technique is based upon input-output ratios, which is independent of inverter loading. Since inverter has fixed relationship between V-in/V-out and I-in/I-out, failure detection criteria are based on this ratio, which is simply inverter transformer turns ratio, K, equal to primary turns divided by secondary turns.

  11. [Associated factors to non-operative management failure of hepatic and splenic lesions secondary to blunt abdominal trauma in children].

    Science.gov (United States)

    Echavarria Medina, Adriana; Morales Uribe, Carlos Hernando; Echavarria R, Luis Guillermo; Vélez Marín, Viviana María; Martínez Montoya, Jorge Alberto; Aguillón, David Fernando

    2017-01-01

    The non operative management (NOM) is the standard management of splenic and liver blunt trauma in pediatric patients.Hemodynamic instability and massive transfusions have been identified as management failures. Few studies evaluate whether there exist factors allowing anticipation of these events. The objective was to identify factors associated with the failure of NOM in splenic and liver injuries for blunt abdominal trauma. Retrospective analysis between 2007-2015 of patients admitted to the pediatric surgery at University Hospital Saint Vincent Foundation with liver trauma and/or closed Spleen. 70 patients were admitted with blunt abdominal trauma, 3 were excluded for immediate surgery (2 hemodynamic instability, 1 peritoneal irritation). Of 67 patients who received NOM, 58 were successful and 9 showed failure (8 hemodynamic instability, 1 hollow viscera injury). We found 3 factors associated with failure NOM: blood pressure (BP) 2 g/dl in the first 24 hours (p = 0.0009; RR = 15.3), and transfusion of 3 or more units of red blood cells (RBC) (0.00001; RR = 17.1). Mechanism and severity of trauma and Pediatric Trauma Index were not associated with failure NOM. Children with blunted hepatic or splenic trauma respond to NOM. Factors such as BP 2 g/dl in the first 24 hours and transfusion of 3 or more units of RBC were associated with the failure in NOM.

  12. A geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machine

    KAUST Repository

    Khelouat, Samir

    2012-06-01

    This paper deals with the problem of detection and isolation of stator short-circuit failure in a single asynchronous machine using a geometric approach. After recalling the basis of the geometric approach for fault detection and isolation in nonlinear systems, we will study some structural properties which are fault detectability and isolation fault filter existence. We will then design filters for residual generation. We will consider two approaches: a two-filters structure and a single filter structure, both aiming at generating residuals which are sensitive to one fault and insensitive to the other faults. Some numerical tests will be presented to illustrate the efficiency of the method.

  13. Evaluation of a vibration diagnostic system for the detection of spur gear pitting failures

    Science.gov (United States)

    Townsend, Dennis P.; Zakrajsek, James J.

    1993-01-01

    A vibration diagnostic system was used to detect spur gear surface pitting fatigue in a closed-loop spur gear fatigue test rig. The diagnostic system, comprising a personal computer with an analog-to-digital conversion board, a diagnostic system unit, and software, uses time-synchronous averaging of the vibration signal to produce a vibration image of each tooth on any gear in a transmission. Several parameters were analyzed including gear pair stress wave and raw baseband vibration, kurtosis, peak ratios, and others. The system provides limits for the various parameters and gives a warning when the limits are exceeded. Several spur gear tests were conducted with this system and vibration data analyzed at 5-min. intervals. The results presented herein show that the system is fairly effective at detecting spur gear tooth surface fatigue pitting failures.

  14. Leak detection system design and operating considerations for the US-CRBRP

    International Nuclear Information System (INIS)

    Kruger, G.B.; Eng, K.Y.; Kelly, W.L.

    1976-01-01

    Diffusion membrane type hydrogen detectors are provided for monitoring the sodium exiting each evaporator and superheater in the Clinch River Breeder Reactor Plant. These detectors allow detection of small water to sodium leaks and provide the plant operator with an early warning signal. Hydrogen detectors are located at the exit sodium streams of each steam generator module, the vent from the module semi-stagnant region, the cold leg piping, and in an intermediate system sodium expansion tank cover gas region. In addition, an electrochemical oxygen detector is located in the cold leg piping. The leak detection system is capable of detecting the presence of steam/water leaks on the order of 0.45 x 10 -5 kg/sec or larger and of signaling within one to three minutes upon initiation of a leak, during normal operation. Operator action is taken upon receipt of a leak signal to shutdown the affected system, by closing steam/water isolation valves and depressurizing the affected unit

  15. System tuning and measurement error detection testing

    International Nuclear Information System (INIS)

    Krejci, Petr; Machek, Jindrich

    2008-09-01

    The project includes the use of the PEANO (Process Evaluation and Analysis by Neural Operators) system to verify the monitoring of the status of dependent measurements with a view to early measurement fault detection and estimation of selected signal levels. At the present stage, the system's capabilities of detecting measurement errors was assessed and the quality of the estimates was evaluated for various system configurations and the formation of empiric models, and rules were sought for system training at chosen process data recording parameters and operating modes. The aim was to find a suitable system configuration and to document the quality of the tuned system on artificial failures

  16. Maintenance of electrolytic cells with failure technologic mode

    International Nuclear Information System (INIS)

    Galushkin, N.V.

    1995-01-01

    This chapter of monograph is devoted to failures in regular operation of electrolytic cell and ways of their neutralization. Thus, the main failures in regular operation of electrolytic cell, including hot driving, cold driving of tank, carbides formation were studied. The emergency cases in operation of tanks and ways of their neutralization were described.

  17. Failure cause and failure rate evaluation on pumps of BWR plants in PSA. Hypothesis testing for typical or plant specific failure rate of pumps

    International Nuclear Information System (INIS)

    Sanada, Takahiro; Nakamura, Makoto

    2009-01-01

    In support of domestic nuclear industry effort to gather and analyze failure data of components concerning nuclear power plants, Nuclear Information Archives (NUCIA) are published for useful information to help PSA. This report focuses on NUCIA pertaining to pumps in domestic nuclear power plants, and provides the reliable estimation on failure rate of pumps resulting from failure cause analysis and hypothesis testing of classified and plant specific failure rate of pumps for improving quality in PSA. The classified and plant specific failure rate of pumps are estimated by analyzing individual domestic nuclear power plant's data of 26 Boiling Water Reactors (BWRs) concerning functionally structurally classified pump failures reported from beginning of commercial operation to March 31, 2007. (author)

  18. Failure analysis on a ruptured petrochemical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Harun, Mohd [Industrial Technology Division, Malaysian Nuclear Agency, Ministry of Science, Technology and Innovation Malaysia, Bangi, Kajang, Selangor (Malaysia); Shamsudin, Shaiful Rizam; Kamardin, A. [Univ. Malaysia Perlis, Jejawi, Arau (Malaysia). School of Materials Engineering

    2010-08-15

    The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

  19. Operational tank leak detection and minimization during retrieval

    International Nuclear Information System (INIS)

    Hertzel, J.S.

    1996-03-01

    This report evaluates the activities associated with the retrieval of wastes from the single-shell tanks proposed under the initial Single-Shell Tank Retrieval System. This report focuses on minimizing leakage during retrieval by using effective leak detection and mitigating actions. After reviewing the historical data available on single-shell leakage, and evaluating current leak detection technology, this report concludes that the only currently available leak detection method which can function within the most probable leakage range is the mass balance system. If utilized after each sluicing campaign, this method should allow detection at a leakage value well below the leakage value where significant health effects occur which is calculated for each tank. Furthermore, this report concludes that the planned sequence or sluicing activities will serve to further minimize the probability and volume of leaks by keeping liquid away from areas with the greatest potential for leaking. Finally, this report identifies a series of operational responses which when used in conjunction with the recommended sluicing sequence and leak detection methods will minimize worker exposure and environmental safety health risks

  20. Operator fatigue detection and countermeasure development

    Energy Technology Data Exchange (ETDEWEB)

    Daniel Bongers [CRC Mining (Australia)

    2009-05-15

    A prototype technology for measuring and reporting an individual's fatigue, with the intention that such a technology could be used to prevent fatigue-related injuries in the Australian coal mining industry is known as the Smart Cap system. It resembles a typical baseball cap yet contains sophisticated sensors capable of measuring EEG (brain waves) through hair, determining an individual's fatigue level and reporting that to an in-cab display. The first phase of developmentwas to develop the sensor capable of reading EEG without the need for conductive gel. Once this was proven, a more sophisticated circuit was developed that incorporated tuned filtering and digital signal processing allowing the brain wave data to be stored and communicated using Bluetooth wireless. The third and final phase was focussed on the embodiment of the sensor array into a baseball cap in order to allow long term use in a mining environment. Two field trials of the Smart Cap fatigue detection system took place at surface coal mining operations in central Queensland during 2008. 53 operators were involved in these trials for one or more shifts. Both day and night shifts were incorporated for operators of haul trucks, excavators, water trucks, dozers and graders. Infrared video footage of some operators was captured for comparison with the real-time EEG and fatigue information collected by the Smart Cap system. This footage allowed the calculation of the percentage of eye closure (PERCLOS) of eleven operators. Comparison of the PERCLOS measurements with operator fatigue levels shows good correlation in line with similar published research. The Smart Cap system performed according to its design parameters. We show that the sophisticated sensor array is capable of eliminating ambient electrical noise in the mine environment, and that the Bluetooth connectivity is secure in the event of intentional mismatching of equipment or close vehicle interactions.

  1. WWER problems and perspectives of moving toward zero fuel failures and mitigation of fuel failure consequences at NPPs with WWER reactors in Russia

    International Nuclear Information System (INIS)

    Shestakov, Yu.; Semenovykh, A.

    2015-01-01

    The paper contained information on mitigation of fuel failures and perspectives of moving to ‘Zero Failure Level’. It was stated that driving to ‘zero’ failure rate should include two kinds of efforts, 1) focus on identification of failure mechanisms, and 2) implement corrective actions. It is also important to mitigate the consequences of fuel failures if that inevitably occurs. Fuel failures entail the risks of severe secondary degradation and contamination of primary circuit due to fuel washout. Significant changes of fuel operating conditions (longer fuel cycles, higher fuel burnup, power uprate) and innovations in fuel design bear the risk of higher failure rates for some period of time. Simultaneous implementation of several innovations in one nuclear utility is not advisable since it might be difficult to identify which of the innovations affected the fuel performance positively or negatively. The disadvantage of gradual implementation of corrective actions and any significant changes in operating conditions is the long time needed to evaluate the operational experience. In some cases, it may take up to 4-6 years for each significant change to reflect on the operational performance

  2. An autonomous recovery mechanism against optical distribution network failures in EPON

    Science.gov (United States)

    Liem, Andrew Tanny; Hwang, I.-Shyan; Nikoukar, AliAkbar

    2014-10-01

    Ethernet Passive Optical Network (EPON) is chosen for servicing diverse applications with higher bandwidth and Quality-of-Service (QoS), starting from Fiber-To-The-Home (FTTH), FTTB (business/building) and FTTO (office). Typically, a single OLT can provide services to both residential and business customers on the same Optical Line Terminal (OLT) port; thus, any failures in the system will cause a great loss for both network operators and customers. Network operators are looking for low-cost and high service availability mechanisms that focus on the failures that occur within the drop fiber section because the majority of faults are in this particular section. Therefore, in this paper, we propose an autonomous recovery mechanism that provides protection and recovery against Drop Distribution Fiber (DDF) link faults or transceiver failure at the ONU(s) in EPON systems. In the proposed mechanism, the ONU can automatically detect any signal anomalies in the physical layer or transceiver failure, switching the working line to the protection line and sending the critical event alarm to OLT via its neighbor. Each ONU has a protection line, which is connected to the nearest neighbor ONU, and therefore, when failure occurs, the ONU can still transmit and receive data via the neighbor ONU. Lastly, the Fault Dynamic Bandwidth Allocation for recovery mechanism is presented. Simulation results show that our proposed autonomous recovery mechanism is able to maintain the overall QoS performance in terms of mean packet delay, system throughput, packet loss and EF jitter.

  3. Towards an operational sensor-fusion system for anti-personnel landmine detection

    NARCIS (Netherlands)

    Cremer, F.; Schutte, K.; Schavemaker, J.G.M.; Breejen, E. den

    2000-01-01

    To acquire detection performance required for an operational system for the detection of anti-personnel landmines, it is necessary to use multiple sensors and sensor-fusion techniques. This paper describes five decision-level sensor-fusion techniques and their common optimisation method. The

  4. Data collection on component malfunctions and failures of JET ICRH system

    International Nuclear Information System (INIS)

    Pinna, T.; Cambi, G.

    2007-01-01

    The objective of the activity was to collect and analyse data coming out from operating experiences gained in the Joint European Torus (JET) for the Ion Cyclotron Resonance Heating (ICRH) system in order to enrich the data collection on failures of components used in fusion facilities. Alarms/Failures and malfunctions occurred in the years of operations from March 1996 to November 2005, including information on failure modes and, where possible, causes of the failures, have been identified. Beyond information on failures and alarms events, also data related to crowbar events have been collected. About 3400 events classified as alarms or failures related to specific components or sub-systems were identified by analysing the 25 hand-written logbooks made available by the ICRH operation staff. Information about the JET pulses in which the ICRH system was operated has been extracted from the tick sheets covering the whole considered time interval. 20 hand written tick sheets cover the period from March 1996 to middle May 2003, while tick sheets recorded as excel files cover the period from May 2003 to November 2005. By analysing the tick sheets it results that the ICRH was operated during about 12000 plasma pulses. Main statistical values, such as rates of alarms/failures and corresponding standard errors and confidence intervals, have been estimated. Failure rates of systems and components have been evaluated both with regard to the ICRH operation pulses and operating days (days in which at least one ICRH module was requested to operate). Failure probabilities on demand have been evaluated with regard to number of pulses operated. Some of the results are the following: - The highest number of alarms/failures (1243) appears to be related to Erratic /No-output of the Instrumentation and Control (I and C) apparatus, followed by faults (829) of the Tetrode circuits, by faults (466) of the High Voltage Power Supply system and by faults (428) of the Tuning elements. - The

  5. Aspects of leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Chivers, T.C. [Berkeley Technology Centre, Glos (United Kingdom)

    1997-04-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant.

  6. Aspects of leak detection

    International Nuclear Information System (INIS)

    Chivers, T.C.

    1997-01-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant

  7. Material failures observed in the Doublet III neutral beamlines

    International Nuclear Information System (INIS)

    Bailey, E.W.; Colleraine, A.; Doll, D.; Grunloh, H.; Kim, J.; Langhorn, A.; Thurgood, B.

    1983-01-01

    The Doublet III neutral beam injectors consist of three separable spools two meters in diameter by four meters long overall when assembled. Contained within these spools are the neutralizers, ion dumps, deflecting magnet, calorimeter dumps, cryogenic panels and beam scraping collimators. To date three beamlines are in operation on Doublet III, and the beams have accumulated operating time of approximately 32 months, with the oldest having been in operation for 18 months. During this time operation of DIII with the neutral beam sources has demonstrated the following: 7.8 MW injected neutrals from three beamlines (6 sources), high β (4.5%), and non-circular plasma shape. The sources have also exibited a very reliable injected shot history. Material failures encountered during the operation of DIII N.B. injectors and the solutions to these failures are described. Failures include cracking of the neutralizer exit collimator due to heating cycles, failure of cyropanel support rods due to cooling cycles, failure of the sliding drive of the moveable calorimeter due to friction

  8. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  9. Modular space vehicle boards, control software, reprogramming, and failure recovery

    Science.gov (United States)

    Judd, Stephen; Dallmann, Nicholas; McCabe, Kevin; Delapp, Jerry; Prichard, Dean; Proicou, Michael; Seitz, Daniel; Stein, Paul; Michel, John; Tripp, Justin; Palmer, Joseph; Storms, Steven

    2017-09-12

    A space vehicle may have a modular board configuration that commonly uses some or all components and a common operating system for at least some of the boards. Each modular board may have its own dedicated processing, and processing loads may be distributed. The space vehicle may be reprogrammable, and may be launched without code that enables all functionality and/or components. Code errors may be detected and the space vehicle may be reset to a working code version to prevent system failure.

  10. Failed fuel detection device

    International Nuclear Information System (INIS)

    Sudo, Takayuki.

    1983-01-01

    Purpose: To enable early and sure detection of failed fuels by automatically changing the alarm set value depending on the operation states of a nuclear reactor. Constitution: Gaseous fission products released into coolants are transferred further into cover gases and then introduced through a pipeway to a failed fuel detector. The cover gases introduced from the pipeway to the pipeway or chamber within the detection device are detected by a radiation detector for the radiation dose of the gaseous fission products contained therein. The detected value is converted and amplified as a signal and inputted to a comparator. While on the other hand, a signal corresponding to the reactor power is converted by an alarm setter into a set value and inputted to the comparator. In such a structure, early and sure detection can be made for the fuel failures. (Yoshino, Y.)

  11. An estimation method of system failure frequency using both structure and component failure data

    International Nuclear Information System (INIS)

    Takaragi, Kazuo; Sasaki, Ryoichi; Shingai, Sadanori; Tominaga, Kenji

    1981-01-01

    In recent years, the importance of reliability analysis is appreciated for large systems such as nuclear power plants. A reliability analysis method is described for a whole system, using structure failure data for its main working subsystem and component failure data for its safety protection subsystem. The subsystem named main working system operates normally, and the subsystem named safety protection system acts as standby or protection. Thus the main and the protection systems are given mutually different failure data; then, between the subsystems, there exists common mode failure, i.e. the component failure affecting the reliability of both two. A calculation formula for sytem failure frequency is first derived. Then, a calculation method with digraphs is proposed for conditional system failure probability. Finally the results of numerical calculation are given for the purpose of explanation. (J.P.N.)

  12. U.S. Department Of Energy's nuclear engineering education research: highlights of recent and current research-III. 4. Early Detection of Plant Equipment Failures: A Case Study in Just-In-Time Maintenance

    International Nuclear Information System (INIS)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-01-01

    the motor current spectrum. Processing the motor current measurements as shown in the bottom part of the figure reveals different results. The indicator clearly distinguishes the existence of a good and bad bearing. The lowest indicator magnitude corresponds to the experiments with good bearings, whereas the varying indicator magnitude corresponds to bearings with varying defect levels. Similar results are obtained for other types of mechanical failures, and the proposed indicator is found to be insensitive to load variations. The presented case studies constitute some of the 56 scenarios used to test the developed fault detection system on a 3-hp motor system. The various scenarios include healthy operation, deteriorating bearings, broken rotor bars, stator turn-to-turn winding shorts, and power supply unbalance. Table I shows the detection effectiveness of the developed system for several different levels of fault decision thresholds. The detection effectiveness, defined as the ratio of the number of correctly detected cases to the total number of tested cases, depends on how the user selects the fault threshold. It is very important to select a fault threshold that will result in a low rate of false alarms and missed faults; however, these are two competing effects. (authors)

  13. Interrelationships Between Receiver/Relative Operating Characteristics Display, Binomial, Logit, and Bayes' Rule Probability of Detection Methodologies

    Science.gov (United States)

    Generazio, Edward R.

    2014-01-01

    Unknown risks are introduced into failure critical systems when probability of detection (POD) capabilities are accepted without a complete understanding of the statistical method applied and the interpretation of the statistical results. The presence of this risk in the nondestructive evaluation (NDE) community is revealed in common statements about POD. These statements are often interpreted in a variety of ways and therefore, the very existence of the statements identifies the need for a more comprehensive understanding of POD methodologies. Statistical methodologies have data requirements to be met, procedures to be followed, and requirements for validation or demonstration of adequacy of the POD estimates. Risks are further enhanced due to the wide range of statistical methodologies used for determining the POD capability. Receiver/Relative Operating Characteristics (ROC) Display, simple binomial, logistic regression, and Bayes' rule POD methodologies are widely used in determining POD capability. This work focuses on Hit-Miss data to reveal the framework of the interrelationships between Receiver/Relative Operating Characteristics Display, simple binomial, logistic regression, and Bayes' Rule methodologies as they are applied to POD. Knowledge of these interrelationships leads to an intuitive and global understanding of the statistical data, procedural and validation requirements for establishing credible POD estimates.

  14. ANALYSIS OF RELIABILITY OF NONRECTORABLE REDUNDANT POWER SYSTEMS TAKING INTO ACCOUNT COMMON FAILURES

    Directory of Open Access Journals (Sweden)

    V. A. Anischenko

    2014-01-01

    Full Text Available Reliability Analysis of nonrestorable redundant power Systems of industrial plants and other consumers of electric energy was carried out. The main attention was paid to numbers failures influence, caused by failures of all elements of System due to one general reason. Noted the main possible reasons of common failures formation. Two main indicators of reliability of non-restorable systems are considered: average time of no-failure operation and mean probability of no-failure operation. Modeling of failures were carried out by mean of division of investigated system into two in-series connected subsystems, one of them indicated independent failures, but the other indicated common failures. Due to joined modeling of single and common failures resulting intensity of failures is the amount incompatible components: intensity statistically independent failures and intensity of common failures of elements and system in total.It is shown the influence of common failures of elements on average time of no-failure operation of system. There is built the scale of preference of systems according to criterion of  average time maximum of no-failure operation, depending on portion of common failures. It is noticed that such common failures don’t influence on the scale of preference, but  change intervals of time, determining the moments of systems failures and excepting them from the number of comparators. There were discussed two problems  of conditionally optimization of  systems’  reservation choice, taking into account their reliability and cost. The first problem is solved due to criterion of minimum cost of system providing mean probability of no-failure operation, the second problem is solved due to criterion of maximum of mean probability of no-failure operation with cost limitation of system.

  15. [Handling the cases of school failure in an educational institute in Zaghouan].

    Science.gov (United States)

    Abdelkafi Koubaa, Afifa; Bouslama, Samira; Bel Abed, Najet; Dahmen, Hayet; Mira Gabsi, Zvine; Gabsi, Abdallah; Ouerfelli, Nabil; Mabaouj, Mohamed Taher; Bachouche, Imen

    2011-10-01

    To assess the main reasons for the school failure in a school in Zaghouan, how to handle these issues, to evaluate the work of the school social office. A retrospective study included 86 failure cases in a school in Zaghouan, handled by the school social office for three years (2004 - 2007). He have detected the principals causes of school failure, detected by the educational staff or by the listening office. The causes of failure are mainly social (46%) as family problems and low income. These families received financial aids and free treatment cards. Discussions have been made with the parents in order to make them more conscious. The pedagogical reasons (28%) however are usually relationship' problems between the student and his teacher or the student and the administration, the three subjects were informed so that attitudes could be changed in the purpose of helping the student. Twelve students (14%) have a psychological case, depression and over worrying, led in some cases to addiction.These cases were diagnosed and transferred to specialized clinics.Sense and chronic diseases (12%), are considered as health reasons for school failure and caused several absences in the school. The school physicist took care of these cases by handling them medical guidance cards while observing the diagnose progress. As school results, 56 cases turned satisfaisant which is 65 % of all cases. The school failure became a priority of the "School Health" institute. That puss to create the school social program, his aim is protecting the students from all dangers, early school leaving and social disintegration, and delinquency. Thus, all parts must be responsible for the school failure, teachers, parents, students,psychiatrists and physicists, as well as introducing the social school work and listening offices and missions to the parents, students and teachers in order to guarantee the success of the operations.

  16. Failure characteristic analysis of a component on standby state

    International Nuclear Information System (INIS)

    Shin, Sungmin; Kang, Hyungook

    2013-01-01

    Periodic operations for a specific type of component, however, can accelerate aging effects which increase component unavailability. For the other type of components, the aging effect caused by operation can be ignored. Therefore frequent operations can decrease component unavailability. Thus, to get optimum unavailability proper operation period and method should be studied considering the failure characteristics of each component. The information of component failure is given according to the main causes of failure depending on time flow. However, to get the optimal unavailability, proper interval of operation for inspection should be decided considering the time dependent and independent causes together. According to this study, gradually shorter operation interval for inspection is better to get the optimal component unavailability than that of specific period

  17. Analysis of failure dependent test, repair and shutdown strategies for redundant trains

    International Nuclear Information System (INIS)

    Uryasev, S.; Samanta, P.

    1994-09-01

    Failure-dependent testing implies a test of a redundant components (or trains) when failure of one component has been detected. The purpose of such testing is to detect any common cause failures (CCFs) of multiple components so that a corrective action such as repair or plant shutdown can be taken to reduce the residence time of multiple failures, given a failure has been detected. This type of testing focuses on reducing the conditional risk of CCFs. Formulas for calculating the conditional failure probability of a two train system with different test, repair and shutdown strategies are developed. A methodology is presented with an example calculation showing the risk-effectiveness of failure-dependent strategies for emergency diesel generators (EDGs) in nuclear power plants (NPPs)

  18. System for detecting operating errors in a variable valve timing engine using pressure sensors

    Science.gov (United States)

    Wiles, Matthew A.; Marriot, Craig D

    2013-07-02

    A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

  19. Detecting Anomalies by Fusing Voice and Operations Data, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Our innovation will detect, in near real-time, NAS operational anomalies by uniquely combing with analytical methods our existing Microsoft Azure based TFMData...

  20. The quench detection system of Wendelstein 7-X

    International Nuclear Information System (INIS)

    Birus, Dietrich; Schneider, Matthias; Rummel, Thomas; Fricke, Marko

    2011-01-01

    The Quench Detection System of Wendelstein W7-X has been developed, pretested and manufactured during the last four years. This safety subsystem of the superconducting magnet power supply will guarantee the safe operating of the whole magnet system. The main targets of the Quench Detection System are the complete data acquisition of all the voltages along the superconducting components, i.e. non planar and planar coils, and bus bars, the evaluation of this data and the control of the magnet system safety discharges. The Quench Detection System is generating control commands for the magnet power supply control system and the electrical status of the superconducting components of W7-X. The Quench Detection System consists of nearly 580 Quench Detection Units (QDU) located in 10 QD-subsystems, 8 racks in each, one host system and two special interfaces for evaluation of the quench control commands and the failure signals. The operating software suite of the QD System allows the configuration, the operation and the maintenance of the whole system.

  1. Premature failure of dissimilar metal weld joint at intermediate temperature superheater tube

    OpenAIRE

    Al Hajri, Mohammed; Malik, Anees U.; Meroufel, Abdelkader; Al-Muaili, Fahd

    2015-01-01

    Dissimilar metal weld (DMW) joint between alloyed steel (AS) and stainless steel (SS) failed at one of intermediate temperature superheater (ITSH) tube in steam/power generation plant boiler. The premature failure was detected after a relatively short time of operation (8 years) where the crack propagated circumferentially from AS side through the ITSH tube. Apart from physical examination, microstructural studies based on optical microscopy, SEM and EDX analysis were performed. The results o...

  2. [Review of the knowledge on acute kidney failure in the critical patient].

    Science.gov (United States)

    Romero García, M; Delgado Hito, P; de la Cueva Ariza, L

    2013-01-01

    Acute renal failure affects from 1% to 25% of patients admitted to intensive care units. These figures vary depending on the population studied and criteria. The complications of acute renal failure (fluid overload, metabolic acidosis, hyperkalemia, bleeding) are treated. However, mortality remains high despite the technological advances of recent years because acute renal failure is usually associated with sepsis, respiratory failure, serious injury, surgical complications or consumption coagulopathy. Mortality ranges from 30% to 90%. Although there is no universally accepted definition, the RIFLE classification gives us an operational tool to define the degree of acute renal failure and to standardize the initiation of renal replacement techniques as well as to evaluate the results. Therefore, nurses working within the intensive care unit must be familiar with this disease, with its treatment (drug or alternative) and with the prevention of possible complications. Equally, they must be capable of detecting the manifestations of dependency each one of the basic needs and to be able to identify the collaboration problems in order to achieve an individualized care plan. Copyright © 2012 Elsevier España, S.L. y SEEIUC. All rights reserved.

  3. Failed fuel diagnosis during WWER reactor operation using the RTOP-CA code

    International Nuclear Information System (INIS)

    Likhanskii, V.; Afanasieva, E.; Sorokin, A.; Evdokimov, I.; Kanukova, V.; Khromov, A.

    2006-01-01

    The mechanistic code RTOP-CA is developed for objectives of failed fuel diagnosis during WWER reactor operation. The RTOP-CA code enables to solve a direct problem: modelling the failed fuel behavior and prediction of primary coolant activity if characteristics of failures in the reactor core are known. Results of verification of the RTOP-CA code are presented. Separate physical models were verified on small-scale in-pile and out-of-pile experiments. Integral verification cases included data obtained at research reactors and at nuclear power plants. The RTOP-CA code is used for development of a neural-network approach to the inverse problem: detection of failure characteristics on the base of data on primary coolant activity during reactor operation. Preliminary results of application of the neural-network approach for evaluation of fuel failure characteristics are presented. (authors)

  4. Utilizing foreign operating experience to derive reliability data - especially for common mode failures

    International Nuclear Information System (INIS)

    Bongartz, R.; Hennings, W.; Meessen, H.

    1987-11-01

    Failure rates for common mode failures of redundant components of the same design are derived from abnormal occurrences in safety systems of US nuclear power stations for use on a national level. The available raw data of interest for pumps and valves (processed Licensee Event Reports) are progressively re-evaluated and checked for transferability of German conditions. Most of the common mode failures (CMF) experienced affected only part of the redundancies; the homogeneous Marshall-Olkin model is therefore used to determine failure rates for both partial and total failures of redundant components. Some few results based on zero failure statistics and a small data base (four-train systems) seem to be too conservative. On the whole, however, the application of the data determined here does not provide any unrealistically high system unavailabilities. (orig.) [de

  5. Distributed Multi-Level Supervision to Effectively Monitor the Operations of a Fleet of Autonomous Vehicles in Agricultural Tasks

    Directory of Open Access Journals (Sweden)

    Jesús Conesa-Muñoz

    2015-03-01

    Full Text Available This paper describes a supervisor system for monitoring the operation of automated agricultural vehicles. The system analyses all of the information provided by the sensors and subsystems on the vehicles in real time and notifies the user when a failure or potentially dangerous situation is detected. In some situations, it is even able to execute a neutralising protocol to remedy the failure. The system is based on a distributed and multi-level architecture that divides the supervision into different subsystems, allowing for better management of the detection and repair of failures. The proposed supervision system was developed to perform well in several scenarios, such as spraying canopy treatments against insects and diseases and selective weed treatments, by either spraying herbicide or burning pests with a mechanical-thermal actuator. Results are presented for selective weed treatment by the spraying of herbicide. The system successfully supervised the task; it detected failures such as service disruptions, incorrect working speeds, incorrect implement states, and potential collisions. Moreover, the system was able to prevent collisions between vehicles by taking action to avoid intersecting trajectories. The results show that the proposed system is a highly useful tool for managing fleets of autonomous vehicles. In particular, it can be used to manage agricultural vehicles during treatment operations.

  6. Distributed multi-level supervision to effectively monitor the operations of a fleet of autonomous vehicles in agricultural tasks.

    Science.gov (United States)

    Conesa-Muñoz, Jesús; Gonzalez-de-Soto, Mariano; Gonzalez-de-Santos, Pablo; Ribeiro, Angela

    2015-03-05

    This paper describes a supervisor system for monitoring the operation of automated agricultural vehicles. The system analyses all of the information provided by the sensors and subsystems on the vehicles in real time and notifies the user when a failure or potentially dangerous situation is detected. In some situations, it is even able to execute a neutralising protocol to remedy the failure. The system is based on a distributed and multi-level architecture that divides the supervision into different subsystems, allowing for better management of the detection and repair of failures. The proposed supervision system was developed to perform well in several scenarios, such as spraying canopy treatments against insects and diseases and selective weed treatments, by either spraying herbicide or burning pests with a mechanical-thermal actuator. Results are presented for selective weed treatment by the spraying of herbicide. The system successfully supervised the task; it detected failures such as service disruptions, incorrect working speeds, incorrect implement states, and potential collisions. Moreover, the system was able to prevent collisions between vehicles by taking action to avoid intersecting trajectories. The results show that the proposed system is a highly useful tool for managing fleets of autonomous vehicles. In particular, it can be used to manage agricultural vehicles during treatment operations.

  7. Receiver Operating Characteristic Analysis for Detecting Explosives-related Threats

    Energy Technology Data Exchange (ETDEWEB)

    Oxley, Mark E; Venzin, Alexander M

    2012-11-14

    The Department of Homeland Security (DHS) and the Transportation Security Administration (TSA) are interested in developing a standardized testing procedure for determining the performance of candidate detection systems. This document outlines a potential method for judging detection system performance as well as determining if combining the information from a legacy system with a new system can signicantly improve performance. In this document, performance corresponds to the Neyman-Pearson criterion applied to the Receiver Operating Characteristic (ROC) curves of the detection systems in question. A simulation was developed to investigate how the amount of data provided by the vendor in the form of the ROC curve eects the performance of the combined detection system. Furthermore, the simulation also takes into account the potential eects of correlation and how this information can also impact the performance of the combined system.

  8. Analysis of fuel operational reliability and fuel failures

    International Nuclear Information System (INIS)

    Smiesko, I.

    1999-01-01

    In this lecture the fuel failure (loss of fuel rod (cladding) integrity, corruption of second barrier for fission product release from duel and their consequences (increase of primary coolant activity; increase of fission product releases to environment; increase of rad-waste activities and potential increase of personnel exposure) are discussed

  9. Inservice diagnostic methods for solenoid-operated valves

    International Nuclear Information System (INIS)

    Kryter, R.C.

    1993-01-01

    Solenoid-operated valves (SOVs) were studied at Oak Ridge National Laboratory as part of the USNRC Nuclear Plant Aging Research (NPAR) Program. The primary objective of the study was to identify, evaluate, and recommend methods for inspection, surveillance, monitoring, and maintenance of SOVs that can help ensure their operational readiness-that is, their ability to perform required safety functions under all anticipated operating conditions, since failure of one of these small and relatively inexpensive devices could have serious consequences under certain circumstances. An earlier (Phase 1) NPAR program study described SOV failure modes and causes and had identified measurable parameters thought to be linked to the progression of everpresent degradation mechanisms that may ultimately result in functional failure of the valve. Using this earlier work as a guide, the present (Phase 11) study focused on devising and then demonstrating the effectiveness of techniques and equipment with which to measure performance parameters that show promise for detecting the presence and trending the progress of such degradations before they reach a critical stage. Intrusive techniques requiring the addition of magnetic or acoustic sensors or the application of special test signals were investigated briefly, but major emphasis was placed on the examination of condition-indicating techniques that can be applied with minimal cost and impact on plant operation. Experimental results are presented that demonstrate the technical feasibility and practicality of the monitoring techniques assessed in the study, and recommendations for further work are provided

  10. Review of electricity supply failures and plant improvements over 25 years operation of the Harwell materials test reactors

    International Nuclear Information System (INIS)

    Taylor, D.J.

    1986-01-01

    The evolution of the on-site electrical power sources is described, operational experience is reported and shortcomings are identified. Disturbances in the external power supplies to the reactors are listed for the past 25 years and failure probabilities are derived from this historical data. The 132 kV overhead supply to the Harwell site is identified as the source of nearly 90% of the disturbances. (author)

  11. Review of electricity supply failures and plant improvements over 25 years operation of the Harwell materials test reactors

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, D. J. [UKAEA Harwell (United Kingdom)

    1986-02-15

    The evolution of the on-site electrical power sources is described, operational experience is reported and shortcomings are identified. Disturbances in the external power supplies to the reactors are listed for the past 25 years and failure probabilities are derived from this historical data. The 132 kV overhead supply to the Harwell site is identified as the source of nearly 90% of the disturbances. (author)

  12. Detecting and mitigating aging in component cooling water systems

    International Nuclear Information System (INIS)

    Lofaro, R.J.

    1991-01-01

    The time-dependent effects of aging on component cooling water (CCW) systems in nuclear power plants has been studied and documented as part of a research program sponsored by the US Nuclear Regulatory Commission. It was found that age related degradation leads to failures in the CCW system which can result in an increase in system unavailability, if not properly detected and mitigated. To identify effective methods of managing this degradation, information on inspection, monitoring, and maintenance practices currently available was obtained from various operating plants and reviewed. The findings were correlated with the most common aging mechanisms and failure modes and a compilation of aging detection and mitigation practices was formulated. This paper discusses the results of this work

  13. Detecting and mitigating aging in component cooling water systems

    International Nuclear Information System (INIS)

    Lofaro, R.J.; Aggarwal, S.

    1992-01-01

    The time-dependent effects of aging on component cooling water (CCW) systems in nuclear power plants has been studied and documented as part of a research program sponsored by the US Nuclear Regulatory Commission. It was found that age related degradation leads to failures in the CCW system which can result in an increase in system unavailability, if not properly detected and mitigated. To identify effective methods of managing this degradation, information on inspection, monitoring, and maintenance practices currently available was obtained from various operating plants and reviewed. The findings were correlated with the most common aging mechanisms and failure modes, and a compilation of aging detection and mitigation practices was formulated. This paper discusses the results of this work

  14. Detection of defective fuel rods in water reactors - a review

    International Nuclear Information System (INIS)

    Hartog, J.M.

    1980-01-01

    Consideration of the fundamental processes of fission product release within fuel pellets and at the pellet surface, and its transport in the fuel/cladding interspace and from fuel rod to coolant, indicates what radio-nuclides will be detectable in the coolant from small and large cladding failures. A better understanding of the aggregate fission product transport is required to allow reactor operators to interpret signals from detection systems in terms of quantitative cladding deterioration. This needs experimental investigation in a specially instrumented loop, as well as development of a technique to cause a rod to defect deliberately during steady power operation. (author)

  15. Development of a system for automatic detection of pellet failures; Desarrollo de un sistema para deteccion automatica de fallas en pastillas

    Energy Technology Data Exchange (ETDEWEB)

    Lavagnino, C E [Comision Nacional de Energia Atomica, San Martin (Argentina). Unidad de Actividad Combustibles Nucleares

    1997-12-31

    Nowadays, the failure controls in UO{sub 2} pellets for Atucha and Embalse reactors are performed visually. In this work it is presented the first stage of the development of a system that allows an automatic approach to the task. For this purpose, the problem has been subdivided in three jobs: choosing the illumination environment, finding the algorithm that detects failures with user-defined tolerance and engineering the mechanic system that supports the desired manipulations of the pellets. In this paper, the former two are developed. a) Finding the illumination conditions that allow subtracting the failure from the normal element surface, knowing, in first place, the cylindrical characteristics of it and, as a consequence, the differences in the light reflection direction and, in second place, the texture differences in relation to the rectification type of the pellet. b) Writing a fast and simple algorithm that allows the identification of the failure following the production specifications. Examples of the developed algorithm are shown. (author). 4 refs.

  16. Using field feedback to estimate failure rates of safety-related systems

    International Nuclear Information System (INIS)

    Brissaud, Florent

    2017-01-01

    The IEC 61508 and IEC 61511 functional safety standards encourage the use of field feedback to estimate the failure rates of safety-related systems, which is preferred than generic data. In some cases (if “Route 2_H” is adopted for the 'hardware safety integrity constraints”), this is even a requirement. This paper presents how to estimate the failure rates from field feedback with confidence intervals, depending if the failures are detected on-line (called 'detected failures', e.g. by automatic diagnostic tests) or only revealed by proof tests (called 'undetected failures'). Examples show that for the same duration and number of failures observed, the estimated failure rates are basically higher for “undetected failures” because, in this case, the duration observed includes intervals of time where it is unknown that the elements have failed. This points out the need of using a proper approach for failure rates estimation, especially for failures that are not detected on-line. Then, this paper proposes an approach to use the estimated failure rates, with their uncertainties, for PFDavg and PFH assessment with upper confidence bounds, in accordance with IEC 61508 and IEC 61511 requirements. Examples finally show that the highest SIL that can be claimed for a safety function can be limited by the 90% upper confidence bound of PFDavg or PFH. The requirements of the IEC 61508 and IEC 61511 relating to the data collection and analysis should therefore be properly considered for the study of all safety-related systems. - Highlights: • This paper deals with requirements of the IEC 61508 and IEC 61511 for using field feedback to estimate failure rates of safety-related systems. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are detected on-line. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are only revealed by

  17. The human failure factors during emergency operating

    International Nuclear Information System (INIS)

    Liu Bingji

    1994-01-01

    In the case of emergency operating, operating staff usually are in the limit state of mind, so the operating mistake rate will go up sharply, and the disastrous accidents usually will happen at this moment. So to study and resolve the problem is very important and imperative. Basing on raising the reliability of man-machine system, the psychology and pathology of operating staff under the limit state and the behavior characteristic of operating staff in the emergency operation have been expounded here, and the operating staff's psychological gradation partitioned by foreign experts also has been introduced, and the influence factors of psychology and equipment which lead to the limit state of mind also have been analyzed. In addition, taking the emergency operation of the nuclear power plant as a example, The authors has studied the countermeasures to prevent the limit state from occurring, which includes countermeasures to environment effects, measures to improve the technical equipment and the measures that the operating staff should be taken

  18. Si-semiconductor device failure mechanisms

    International Nuclear Information System (INIS)

    Clauss, H.

    1976-12-01

    This report presents investigations on failure mechanisms that may cause defects during production and operation of silicon semiconductor devices. The failure analysis of aluminium metallization defects covers topics such as step coverage, dissolution pits and electromigration. Furthermore, the generation of process induced lattice defects was investigated. Improved processes avoiding those defects were developed. (orig.) [de

  19. Operating experience feedback report - Solenoid-operated valve problems

    International Nuclear Information System (INIS)

    Ornstein, H.L.

    1991-02-01

    This report highlights significant operating events involving observed or potential common-mode failures of solenoid-operated valves (SOVs) in US plants. These events resulted in degradation or malfunction of multiple trains of safety systems as well as of multiple safety systems. On the basis of the evaluation of these events, the Office for Analysis and Evaluation of Operational Data (AEOD) of the US Nuclear Regulatory Commission (NRC) concludes that the problems with solenoid-operated valves are an important issue that needs additional NRC and industry attention. This report also provides AEOD's recommendations for actions to reduce the occurrence of SOV common-mode failures. 115 refs., 7 figs., 2 tabs

  20. A Study of Failure Events in Drinking Water Systems As a Basis for Comparison and Evaluation of the Efficacy of Potable Reuse Schemes.

    Science.gov (United States)

    Onyango, Laura A; Quinn, Chloe; Tng, Keng H; Wood, James G; Leslie, Greg

    2015-01-01

    Potable reuse is implemented in several countries around the world to augment strained water supplies. This article presents a public health perspective on potable reuse by comparing the critical infrastructure and institutional capacity characteristics of two well-established potable reuse schemes with conventional drinking water schemes in developed nations that have experienced waterborne outbreaks. Analysis of failure events in conventional water systems between 2003 and 2013 showed that despite advances in water treatment technologies, drinking water outbreaks caused by microbial contamination were still frequent in developed countries and can be attributed to failures in infrastructure or institutional practices. Numerous institutional failures linked to ineffective treatment protocols, poor operational practices, and negligence were detected. In contrast, potable reuse schemes that use multiple barriers, online instrumentation, and operational measures were found to address the events that have resulted in waterborne outbreaks in conventional systems in the past decade. Syndromic surveillance has emerged as a tool in outbreak detection and was useful in detecting some outbreaks; increases in emergency department visits and GP consultations being the most common data source, suggesting potential for an increasing role in public health surveillance of waterborne outbreaks. These results highlight desirable characteristics of potable reuse schemes from a public health perspective with potential for guiding policy on surveillance activities.

  1. Orion Burn Management, Nominal and Response to Failures

    Science.gov (United States)

    Odegard, Ryan; Goodman, John L.; Barrett, Charles P.; Pohlkamp, Kara; Robinson, Shane

    2016-01-01

    An approach for managing Orion on-orbit burn execution is described for nominal and failure response scenarios. The burn management strategy for Orion takes into account per-burn variations in targeting, timing, and execution; crew and ground operator intervention and overrides; defined burn failure triggers and responses; and corresponding on-board software sequencing functionality. Burn-to- burn variations are managed through the identification of specific parameters that may be updated for each progressive burn. Failure triggers and automatic responses during the burn timeframe are defined to provide safety for the crew in the case of vehicle failures, along with override capabilities to ensure operational control of the vehicle. On-board sequencing software provides the timeline coordination for performing the required activities related to targeting, burn execution, and responding to burn failures.

  2. ERB-II operating experience

    International Nuclear Information System (INIS)

    Smith, R.N.; Cissel, D.W.; Smith, R.R.

    1977-01-01

    As originally designed and operated, EBR-II successfully demonstrated the concept of a sodium-cooled fast breeder power plant with a closed fuel reprocessing cycle (mini-nuclear park). Subsequent operation has been as an irradiation facility, a role which will continue into the foreseeable future. Since the beginning of operation in 1961, operating experience of EBR-II has been very satisfactory. Most of the components and systems have performed well. In particular, the mechanical performance of heat-removal systems has been excellent. A review of the operating experience reveals that all the original design objectives have been successfully demonstrated. To date, no failures or incidents resulting in serious in-core or out-of-core consequences have occurred. No water-to-sodium leaks have been detected over the life of the plant. At the present time, the facility is operating very well and continuously except for short shutdowns required by maintenance, refueling, modification, and minor repair. A plant factor of 76.9% was achieved for the calendar year 1976

  3. Failure probability analysis of optical grid

    Science.gov (United States)

    Zhong, Yaoquan; Guo, Wei; Sun, Weiqiang; Jin, Yaohui; Hu, Weisheng

    2008-11-01

    Optical grid, the integrated computing environment based on optical network, is expected to be an efficient infrastructure to support advanced data-intensive grid applications. In optical grid, the faults of both computational and network resources are inevitable due to the large scale and high complexity of the system. With the optical network based distributed computing systems extensive applied in the processing of data, the requirement of the application failure probability have been an important indicator of the quality of application and an important aspect the operators consider. This paper will present a task-based analysis method of the application failure probability in optical grid. Then the failure probability of the entire application can be quantified, and the performance of reducing application failure probability in different backup strategies can be compared, so that the different requirements of different clients can be satisfied according to the application failure probability respectively. In optical grid, when the application based DAG (directed acyclic graph) is executed in different backup strategies, the application failure probability and the application complete time is different. This paper will propose new multi-objective differentiated services algorithm (MDSA). New application scheduling algorithm can guarantee the requirement of the failure probability and improve the network resource utilization, realize a compromise between the network operator and the application submission. Then differentiated services can be achieved in optical grid.

  4. Design of a application of failure registration in equipment of radiotherapy treatments; Diseno de una aplicacion de registro de averias en los equipos de tratamientos radioterapico

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Ortega, J.; Rodriguez Cobo, C.; Pinto Monedero, M.; Rodriguez Romero, R.; Castro Tejero, P.; Sanchez Rubio, P.; Quintana Paz, A.

    2013-07-01

    It has developed an application that aims to provide a centralized database of service interventions, and can detect deficiencies at the time of response, percentages of operability or persistent failures in units. (Author)

  5. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  6. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Science.gov (United States)

    Giancardo, Luca; Mériaudeau, Fabrice; Karnowski, Thomas P.; Tobin, Kenneth W.; Li, Yaqin; Chaum, Edward

    2010-03-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  7. Electrical failure analysis for root-cause determination

    International Nuclear Information System (INIS)

    Riddle, J.

    1990-01-01

    This paper outlines a practical failure analysis sequence. Several technical definitions are required. A failure is defined as a component that was operating in a system where the system malfunctioned and the replacement of the device restored system functionality. The failure mode is the malfunctioning behavior of the device. The failure mechanism is the underlying cause or source of the failure mode. The failure mechanism is the root cause of the failure mode. The failure analysis procedure needs to be adequately refined to result in the determination of the cause of failure to the degree that corrective action or design changes will prevent recurrence of the failure mode or mechanism. An example of a root-cause determination analysis performed for a nuclear power industry customer serves to illustrate the analysis methodology

  8. Inversion Method for Early Detection of ARES-1 Case Breach Failure

    Science.gov (United States)

    Mackey, Ryan M.; Kulikov, Igor K.; Bajwa, Anupa; Berg, Peter; Smelyanskiy, Vadim

    2010-01-01

    A document describes research into the problem of detecting a case breach formation at an early stage of a rocket flight. An inversion algorithm for case breach allocation is proposed and analyzed. It is shown how the case breach can be allocated at an early stage of its development by using the rocket sensor data and the output data from the control block of the rocket navigation system. The results are simulated with MATLAB/Simulink software. The efficiency of an inversion algorithm for a case breach location is discussed. The research was devoted to the analysis of the ARES-l flight during the first 120 seconds after the launch and early prediction of case breach failure. During this time, the rocket is propelled by its first-stage Solid Rocket Booster (SRB). If a breach appears in SRB case, the gases escaping through it will produce the (side) thrust directed perpendicular to the rocket axis. The side thrust creates torque influencing the rocket attitude. The ARES-l control system will compensate for the side thrust until it reaches some critical value, after which the flight will be uncontrollable. The objective of this work was to obtain the start time of case breach development and its location using the rocket inertial navigation sensors and GNC data. The algorithm was effective for the detection and location of a breach in an SRB field joint at an early stage of its development.

  9. Corrosion in electronics: Overview of failures and countermeasures

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Verdingovas, Vadimas; Conseil, Helene

    2014-01-01

    Many field failure returns of electronics are marked as “no failure found”, yet numerous of these failures are likely due to corrosion, since corrosion related failures are not easily detected during subsequent failure analysis. In some cases failures are intermittent and occur because of service...... life conditions (humidity and contamination) where water film formation on the printed circuit board assembly (PCBA) leads to leakage currents resulting in wrong output signal of the electronic device. If the leakage current itself will not result in malfunctioning of the electronics, the formed water...

  10. Computerized Operator Support System – Phase II Development

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Thomas A.; Boring, Ronald L.; Lew, Roger T.; Thomas, Kenneth D.

    2015-02-01

    A computerized operator support system (COSS) prototype for nuclear control room process control is proposed and discussed. The COSS aids operators in addressing rapid plant upsets that would otherwise result in the shutdown of the power plant and interrupt electrical power generation, representing significant costs to the owning utility. In its current stage of development the prototype demonstrates four advanced functions operators can use to more efficiently monitor and control the plant. These advanced functions consist of: (1) a synthesized and intuitive high level overview display of system components and interrelations, (2) an enthalpy-based mathematical chemical and volume control system (CVCS) model to detect and diagnose component failures, (3) recommended strategies to mitigate component failure effects and return the plant back to pre-fault status, and (4) computer-based procedures to walk the operator through the recommended mitigation actions. The COSS was demonstrated to a group of operators and their feedback was collected. The operators responded positively to the COSS capabilities and features and indicated the system would be an effective operator aid. The operators also suggested several additional features and capabilities for the next iteration of development. Future versions of the COSS prototype will include additional plant systems, flexible computer-based procedure presentation formats, and support for simultaneous component fault diagnosis and dual fault synergistic mitigation action strategies to more efficiently arrest any plant upsets.

  11. Review and analysis of check valve failure data

    International Nuclear Information System (INIS)

    Todd, M.D.; Casada, D.A.

    1992-01-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost and decreased system availability. There has been, in response, additional attention given to check valves by utilities, as well as the US Nuclear Regulatory Commission and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. Oak Ridge National Laboratory is currently conducting a detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are being considered during the review, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions

  12. Acoustical Detection Of Leakage In A Combustor

    Science.gov (United States)

    Puster, Richard L.; Petty, Jeffrey L.

    1993-01-01

    Abnormal combustion excites characteristic standing wave. Acoustical leak-detection system gives early warning of failure, enabling operating personnel to stop combustion process and repair spray bar before leak grows large enough to cause damage. Applicable to engines, gas turbines, furnaces, and other machines in which acoustic emissions at known frequencies signify onset of damage. Bearings in rotating machines monitored for emergence of characteristic frequencies shown in previous tests associated with incipient failure. Also possible to monitor for signs of trouble at multiple frequencies by feeding output of transducer simultaneously to multiple band-pass filters and associated circuitry, including separate trigger circuit set to appropriate level for each frequency.

  13. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G.; ter Rahe, B.; Sloof, G.; de Hullu, J.; van der Velden, J.

    2004-01-01

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  14. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G; ter Rahe, B; Sloof, G; de Hullu, J; van der Velden, J

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  15. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  16. Inverter ratio failure detector

    Science.gov (United States)

    Wagner, A. P.; Ebersole, T. J.; Andrews, R. E. (Inventor)

    1974-01-01

    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

  17. Detection of Special Operations Forces Using Night Vision Devices

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C.M.

    2001-10-22

    Night vision devices, such image intensifiers and infrared imagers, are readily available to a host of nations, organizations, and individuals through international commerce. Once the trademark of special operations units, these devices are widely advertised to ''turn night into day''. In truth, they cannot accomplish this formidable task, but they do offer impressive enhancement of vision in limited light scenarios through electronically generated images. Image intensifiers and infrared imagers are both electronic devices for enhancing vision in the dark. However, each is based upon a totally different physical phenomenon. Image intensifiers amplify the available light energy whereas infrared imagers detect the thermal energy radiated from all objects. Because of this, each device operates from energy which is present in a different portion of the electromagnetic spectrum. This leads to differences in the ability of each device to detect and/or identify objects. This report is a compilation of the available information on both state-of-the-art image intensifiers and infrared imagers. Image intensifiers developed in the United States, as well as some foreign made image intensifiers, are discussed. Image intensifiers are categorized according to their spectral response and sensitivity using the nomenclature of GEN I, GEN II, and GEN III. As the first generation of image intensifiers, GEN I, were large and of limited performance, this report will deal with only GEN II and GEN III equipment. Infrared imagers are generally categorized according to their spectral response, sensor materials, and related sensor operating temperature using the nomenclature Medium Wavelength Infrared (MWIR) Cooled and Long Wavelength Infrared (LWIR) Uncooled. MWIR Cooled refers to infrared imagers which operate in the 3 to 5 {micro}m wavelength electromagnetic spectral region and require either mechanical or thermoelectric coolers to keep the sensors operating at 77 K

  18. Implementing a Parallel Image Edge Detection Algorithm Based on the Otsu-Canny Operator on the Hadoop Platform.

    Science.gov (United States)

    Cao, Jianfang; Chen, Lichao; Wang, Min; Tian, Yun

    2018-01-01

    The Canny operator is widely used to detect edges in images. However, as the size of the image dataset increases, the edge detection performance of the Canny operator decreases and its runtime becomes excessive. To improve the runtime and edge detection performance of the Canny operator, in this paper, we propose a parallel design and implementation for an Otsu-optimized Canny operator using a MapReduce parallel programming model that runs on the Hadoop platform. The Otsu algorithm is used to optimize the Canny operator's dual threshold and improve the edge detection performance, while the MapReduce parallel programming model facilitates parallel processing for the Canny operator to solve the processing speed and communication cost problems that occur when the Canny edge detection algorithm is applied to big data. For the experiments, we constructed datasets of different scales from the Pascal VOC2012 image database. The proposed parallel Otsu-Canny edge detection algorithm performs better than other traditional edge detection algorithms. The parallel approach reduced the running time by approximately 67.2% on a Hadoop cluster architecture consisting of 5 nodes with a dataset of 60,000 images. Overall, our approach system speeds up the system by approximately 3.4 times when processing large-scale datasets, which demonstrates the obvious superiority of our method. The proposed algorithm in this study demonstrates both better edge detection performance and improved time performance.

  19. Leak detection of KNI seals

    International Nuclear Information System (INIS)

    Baranyai, G.; Peter, A.; Windberg, P.

    1990-03-01

    In Unit 3 and 4 of the Paks Nuclear Power Plant, Hungary, KNI type seals are used as lead-throughs with conical nickel sealing rings. Their failure can be critical for the operation of the reactor. An Acoustical Leak Detection System (ALDS) was constructed and tested for the operational testing of the seals. Some individual papers are presented in this collection on the calibration and testing of the ALDS intended to be placed on the top of the reactor vessels. The papers include simulation measurements of Unit 3 of NPP, laboratory experiments, evaluation of measurements, and further development needs with the ALDS. (R.P.) 50 figs.; 19 tabs

  20. A preliminary evaluation of the generalized likelihood ratio for detecting and identifying control element failures in a transport aircraft

    Science.gov (United States)

    Bundick, W. T.

    1985-01-01

    The application of the Generalized Likelihood Ratio technique to the detection and identification of aircraft control element failures has been evaluated in a linear digital simulation of the longitudinal dynamics of a B-737 aircraft. Simulation results show that the technique has potential but that the effects of wind turbulence and Kalman filter model errors are problems which must be overcome.

  1. Fault Detection and Isolation for Wind Turbine Electric Pitch System

    DEFF Research Database (Denmark)

    Zhu, Jiangsheng; Ma, Kuichao; Hajizadeh, Amin

    2017-01-01

    This paper presents a model-based fault detection and isolation scheme applied on electric pitch system of wind turbines. Pitch system is one of the most critical components due to its effect on the operational safety and the dynamics of wind turbines. Faults in this system should be precisely...... detected to prevent failures and decrease downtime. To detect faults of electric pitch actuators and sensors, an extended kalman filter (EKF) based multiple model adaptive estimation (MMAE) designed to estimate the states of the system. The proposed method is demonstrated in case studies. The simulation...

  2. Operating systems and network protocols for wireless sensor networks.

    Science.gov (United States)

    Dutta, Prabal; Dunkels, Adam

    2012-01-13

    Sensor network protocols exist to satisfy the communication needs of diverse applications, including data collection, event detection, target tracking and control. Network protocols to enable these services are constrained by the extreme resource scarcity of sensor nodes-including energy, computing, communications and storage-which must be carefully managed and multiplexed by the operating system. These challenges have led to new protocols and operating systems that are efficient in their energy consumption, careful in their computational needs and miserly in their memory footprints, all while discovering neighbours, forming networks, delivering data and correcting failures.

  3. LANDSAT-8 OPERATIONAL LAND IMAGER CHANGE DETECTION ANALYSIS

    Directory of Open Access Journals (Sweden)

    W. Pervez

    2017-05-01

    Full Text Available This paper investigated the potential utility of Landsat-8 Operational Land Imager (OLI for change detection analysis and mapping application because of its superior technical design to previous Landsat series. The OLI SVM classified data was successfully classified with regard to all six test classes (i.e., bare land, built-up land, mixed trees, bushes, dam water and channel water. OLI support vector machine (SVM classified data for the four seasons (i.e., spring, autumn, winter, and summer was used to change detection results of six cases: (1 winter to spring which resulted reduction in dam water mapping and increases of bushes; (2 winter to summer which resulted reduction in dam water mapping and increase of vegetation; (3 winter to autumn which resulted increase in dam water mapping; (4 spring to summer which resulted reduction of vegetation and shallow water; (5 spring to autumn which resulted decrease of vegetation; and (6 summer to autumn which resulted increase of bushes and vegetation . OLI SVM classified data resulted higher overall accuracy and kappa coefficient and thus found suitable for change detection analysis.

  4. An energy-efficient failure detector for vehicular cloud computing.

    Science.gov (United States)

    Liu, Jiaxi; Wu, Zhibo; Dong, Jian; Wu, Jin; Wen, Dongxin

    2018-01-01

    Failure detectors are one of the fundamental components for maintaining the high availability of vehicular cloud computing. In vehicular cloud computing, lots of RSUs are deployed along the road to improve the connectivity. Many of them are equipped with solar battery due to the unavailability or excess expense of wired electrical power. So it is important to reduce the battery consumption of RSU. However, the existing failure detection algorithms are not designed to save battery consumption RSU. To solve this problem, a new energy-efficient failure detector 2E-FD has been proposed specifically for vehicular cloud computing. 2E-FD does not only provide acceptable failure detection service, but also saves the battery consumption of RSU. Through the comparative experiments, the results show that our failure detector has better performance in terms of speed, accuracy and battery consumption.

  5. Operating system considerations in the multiprocessor MIDAS environment

    International Nuclear Information System (INIS)

    Weaver, D.; Maples, C.; Meng, J.; Rathbun, W.

    1983-01-01

    The operating system for MIDAS provides interfaces for custom hardware, debugging facilities, and run time support. The MIDAS architecture uses various specialized hardware devices for controlling the multiple processors and to achieve high I/O throughput. The operating system interfaces with the custom hardware for diagnostics, problem setup, and loading the processors with user code. After the code is loaded, a debugging facility may be used to examine or modify the program in any of the processors, or all the processors simultaneously. During execution of the code, the operating system monitors the processors for exceptional conditions, detects hardware failures, and gathers statistics on performance. This performance information includes histograms depicting instruction execution frequency and analysis of data flow

  6. Successful treatment of 54 patients with acute renal failure after cardiac surgery

    Directory of Open Access Journals (Sweden)

    Lei CHEN

    2015-06-01

    Full Text Available Objectives To evaluate the result of treatment of acute renal failure (ARF in patients after cardiac surgery. Methods The clinical data of 54 cases admitted to the hospital from Jan. 2004 to Jan. 2014 and suffered from ARF after cardiac surgery were retrospectively analyzed. Among 54 cases, there were 35 males and 19 females, aged from one month to 79 years with a median of 52 years. The surgical procedures included coronary artery bypass grafting (CABG, 10 cases, valve surgery (22 cases, combined CABG and valve surgery (4 cases, operation on aorta (14 case, and radical correction of Fallot tetralogy (4 cases. After the operations mentioned above, 50 patients received continuous renal replacement therapy (CRRT, and 4 patients received peritoneal dialysis. Results Nine patients died, the mortality rate was 16.7%. Exploratory hemostasis by thoracotomy was performed in 8 patients, and extubation failure occurred in 4 cases. Of the 9 non-survivors, 6 died from multiple organ failure (MOF, 2 died from cerebral hemorrhage, and one died from acute respiratory failure. Serum creatinine (SCr and blood urea nitrogen (BUN levels declined obviously after CRRT and peritoneal dialysis (P<0.05, and all the patients were shown to have stable hemodynamics in the course of treatment, and no hemorrhage or embolism occurred. Conclusions ARF after cardiac surgery should be detected early and treated in time. CRRT and peritoneal dialysis are safe, convenient and effective procedures, and may decrease the mortality rate in patients with ARF after cardiac surgery. DOI: 10.11855/j.issn.0557-7402.2015.04.13

  7. Improved methods for dependent failure analysis in PSA

    International Nuclear Information System (INIS)

    Ballard, G.M.; Games, A.M.

    1988-01-01

    The basic design principle used in ensuring the safe operation of nuclear power plant is defence in depth. This normally takes the form of redundant equipment and systems which provide protection even if a number of equipment failures occur. Such redundancy is particularly effective in ensuring that multiple, independent equipment failures with the potential for jeopardising reactor safety will be rare events. However the achievement of high reliability has served to highlight the potentially dominant role of multiple, dependent failures of equipment and systems. Analysis of reactor operating experience has shown that dependent failure events are the major contributors to safety system failures and reactor incidents and accidents. In parallel PSA studies have shown that the results of a safety analysis are sensitive to assumptions made about the dependent failure (CCF) probability for safety systems. Thus a Westinghouse Analysis showed that increasing system dependent failure probabilities by a factor of 5 led to a factor 4 increase in core. This paper particularly refers to the engineering concepts underlying dependent failure assessment touching briefly on aspects of data. It is specifically not the intent of our work to develop a new mathematical model of CCF but to aid the use of existing models

  8. Intelligent systems supporting the control room operators

    International Nuclear Information System (INIS)

    Berger, E.

    1997-01-01

    The operational experience obtained with the various applications of the systems discussed in this paper shows that more consequent use of the systems will make detection and management of disturbances still more efficient and faster. This holds true both for a low level of process automation and for power plants with a high level of automation. As for conventional power plants, the trend clearly is towards higher degrees of automation and consequent application of supporting systems. Thus, higher availability and rapid failure management are achieved, at low effects on normal operation. These systems are monitoring and process control systems, expert systems, and systems for optimal use of the equipment, or systems for post-incident analyses and computer-assisted on-shift protocols, or operating manuals. (orig./CB) [de

  9. Tele-operated search robot for human detection using histogram of oriented objects

    Science.gov (United States)

    Cruz, Febus Reidj G.; Avendaño, Glenn O.; Manlises, Cyrel O.; Avellanosa, James Jason G.; Abina, Jyacinth Camille F.; Masaquel, Albert M.; Siapno, Michael Lance O.; Chung, Wen-Yaw

    2017-02-01

    Disasters such as typhoons, tornadoes, and earthquakes are inevitable. Aftermaths of these disasters include the missing people. Using robots with human detection capabilities to locate the missing people, can dramatically reduce the harm and risk to those who work in such circumstances. This study aims to: design and build a tele-operated robot; implement in MATLAB an algorithm for the detection of humans; and create a database of human identification based on various positions, angles, light intensity, as well as distances from which humans will be identified. Different light intensities were made by using Photoshop to simulate smoke, dust and water drops conditions. After processing the image, the system can indicate either a human is detected or not detected. Testing with bodies covered was also conducted to test the algorithm's robustness. Based on the results, the algorithm can detect humans with full body shown. For upright and lying positions, detection can happen from 8 feet to 20 feet. For sitting position, detection can happen from 2 feet to 20 feet with slight variances in results because of different lighting conditions. The distances greater than 20 feet, no humans can be processed or false negatives can occur. For bodies covered, the algorithm can detect humans in cases made under given circumstances. On three positions, humans can be detected from 0 degrees to 180 degrees under normal, with smoke, with dust, and with water droplet conditions. This study was able to design and build a tele-operated robot with MATLAB algorithm that can detect humans with an overall precision of 88.30%, from which a database was created for human identification based on various conditions, where humans will be identified.

  10. General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

    Science.gov (United States)

    Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark

    2010-01-01

    Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

  11. Fuzzy logic prioritization of failures in a system failure mode, effects and criticality analysis

    International Nuclear Information System (INIS)

    Bowles, John B.; Pelaez, C.E.

    1995-01-01

    This paper describes a new technique, based on fuzzy logic, for prioritizing failures for corrective actions in a Failure Mode, Effects and Criticality Analysis (FMECA). As in a traditional criticality analysis, the assessment is based on the severity, frequency of occurrence, and detectability of an item failure. However, these parameters are here represented as members of a fuzzy set, combined by matching them against rules in a rule base, evaluated with min-max inferencing, and then defuzzified to assess the riskiness of the failure. This approach resolves some of the problems in traditional methods of evaluation and it has several advantages compared to strictly numerical methods: 1) it allows the analyst to evaluate the risk associated with item failure modes directly using the linguistic terms that are employed in making the criticality assessment; 2) ambiguous, qualitative, or imprecise information, as well as quantitative data, can be used in the assessment and they are handled in a consistent manner; and 3) it gives a more flexible structure for combining the severity, occurrence, and detectability parameters. Two fuzzy logic based approaches for assessing criticality are presented. The first is based on the numerical rankings used in a conventional Risk Priority Number (RPN) calculation and uses crisp inputs gathered from the user or extracted from a reliability analysis. The second, which can be used early in the design process when less detailed information is available, allows fuzzy inputs and also illustrates the direct use of the linguistic rankings defined for the RPN calculations

  12. 46 CFR 97.37-50 - Ventilation alarm failure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The...-inch letters “VENTILATION FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15286, Dec. 6...

  13. A REVIEW OF SOFTWARE-INDUCED FAILURE EXPERIENCE.

    Energy Technology Data Exchange (ETDEWEB)

    CHU, T.L.; MARTINEZ-GURIDI, G.; YUE, M.; LEHNER, J.

    2006-09-01

    We present a review of software-induced failures in commercial nuclear power plants (NPPs) and in several non-nuclear industries. We discuss the approach used for connecting operational events related to these failures and the insights gained from this review. In particular, we elaborate on insights that can be used to model this kind of failure in a probabilistic risk assessment (PRA) model. We present the conclusions reached in these areas.

  14. Strategies of learning from failure.

    Science.gov (United States)

    Edmondson, Amy C

    2011-04-01

    Many executives believe that all failure is bad (although it usually provides Lessons) and that Learning from it is pretty straightforward. The author, a professor at Harvard Business School, thinks both beliefs are misguided. In organizational life, she says, some failures are inevitable and some are even good. And successful learning from failure is not simple: It requires context-specific strategies. But first leaders must understand how the blame game gets in the way and work to create an organizational culture in which employees feel safe admitting or reporting on failure. Failures fall into three categories: preventable ones in predictable operations, which usually involve deviations from spec; unavoidable ones in complex systems, which may arise from unique combinations of needs, people, and problems; and intelligent ones at the frontier, where "good" failures occur quickly and on a small scale, providing the most valuable information. Strong leadership can build a learning culture-one in which failures large and small are consistently reported and deeply analyzed, and opportunities to experiment are proactively sought. Executives commonly and understandably worry that taking a sympathetic stance toward failure will create an "anything goes" work environment. They should instead recognize that failure is inevitable in today's complex work organizations.

  15. Application of Machine Learning for Dragline Failure Prediction

    Directory of Open Access Journals (Sweden)

    Taghizadeh Amir

    2017-01-01

    Full Text Available Overburden stripping in open cast coal mines is extensively carried out by walking draglines. Draglines’ unavailability and unexpected failures result in delayed productions and increased maintenance and operating costs. Therefore, achieving high availability of draglines plays a crucial role for increasing economic feasibility of mining projects. Applications of methodologies which can forecast the failure type of dragline based on the available failure data not only help to reduce the maintenance and operating costs but also increase the availability and the production rate. In this study, Machine Learning approaches have been applied for data which has been gathered from an operating coal mine in Turkey. The study methodology consists of three algorithms as: i implementation of K-Nearest Neighbors, ii implementation of Multi-Layer Perceptron, and iii implementation of Radial Basis Function. The algorithms have been utilized for predicting the draglines’ failure types. In this sense, the input data, which are mean time-to-failure, and the output data, failure types, have been fed to the algorithms. The regression analysis of methodologies have been compared and showed the K- Nearest Neighbors has a higher rate of regression which is around 70 percent. Thus, the K-Nearest Neighbor algorithm can be applied in order to preventive components replacement which causes to minimized preventive and corrective cost parameters. The accurate prediction of failure type, indeed, causes to optimized number of inspections. The novelty of this study is application of machine learning approaches in draglines’ reliability subject for first time.

  16. Failure Mode and Effect Analysis for Wind Turbine Systems in China

    DEFF Research Database (Denmark)

    Zhu, Jiangsheng; Ma, Kuichao; N. Soltani, Mohsen

    2017-01-01

    This paper discusses a cost based Failure Mode and Effect Analysis (FMEA) approch for the Wind Turbine (WT) with condition monitoring system in China. Normally, the traditional FMEA uses the Risk Priority Number (RPN) to rank failure modes. But the RPN can be changed with the Condition Monitoring...... Systems (CMS) due to change of the score of detection. The cost of failure mode should also be considered because faults can be detected at an incipient level, and condition-based maintenance can be scheduled. The results show that the proposed failure mode priorities considering their cost consequences...

  17. On experiments to detect possible failures on relativity theory

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1982-01-01

    Conditions under which is expected the failure of Einstein's Relativity are analysed. A complete analysis of a recently proposed experiment by Kolen-Torr is also given showing that it must give a negative result. (Author) [pt

  18. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  19. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  20. NRC Information No. 90-21: Potential failure of motor-operated butterfly valves to operate because valve seat friction was underestimated

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    In October 1988, at Catawba Nuclear Station Unit 1, a motor-operated butterfly valve in the service water system failed to open under high differential pressure conditions. The licensee concluded that the valve manufacturer, BIF/General Signal Corporation, had underestimated the degree to which the material used in the valve seat would harden with age (the responsibility for these valves has been transferred to Paul-Munroe Enertech). This underestimation of the age hardening had led the manufacturer to assume valve seat friction forces that were less than the actual friction forces in the installed valve. To overcome the larger-than-anticipated friction forces, the licensee's engineering staff recommended the open torque switch for 56 butterfly valves be reset to the maximum allowable value. The systems in which these valves are located include the component cooling water system, service water system, and various ventilation systems. By July 26, 1989, the torque switch adjustments were completed at Catawba Units 1 and 2. After reviewing the final settings, the licensee's engineering staff determined that the actuators for three butterfly valves in the component cooling water system might not be able to overcome the friction forces resulting from maximum seat hardening. On December 13, 1989, the licensee determined that the failure of these BIF/General Signal motor-operated valves (MOVs) could cause a loss of cooling water to residual heat removal system heat exchangers. To resolve the concern regarding the operability of these BIF/General Signal valves, a torque switch bypass was installed on two of the actuators to allow full motor capability during opening

  1. MEMS Reliability: Infrastructure, Test Structures, Experiments, and Failure Modes

    Energy Technology Data Exchange (ETDEWEB)

    TANNER,DANELLE M.; SMITH,NORMAN F.; IRWIN,LLOYD W.; EATON,WILLIAM P.; HELGESEN,KAREN SUE; CLEMENT,J. JOSEPH; MILLER,WILLIAM M.; MILLER,SAMUEL L.; DUGGER,MICHAEL T.; WALRAVEN,JEREMY A.; PETERSON,KENNETH A.

    2000-01-01

    The burgeoning new technology of Micro-Electro-Mechanical Systems (MEMS) shows great promise in the weapons arena. We can now conceive of micro-gyros, micro-surety systems, and micro-navigators that are extremely small and inexpensive. Do we want to use this new technology in critical applications such as nuclear weapons? This question drove us to understand the reliability and failure mechanisms of silicon surface-micromachined MEMS. Development of a testing infrastructure was a crucial step to perform reliability experiments on MEMS devices and will be reported here. In addition, reliability test structures have been designed and characterized. Many experiments were performed to investigate failure modes and specifically those in different environments (humidity, temperature, shock, vibration, and storage). A predictive reliability model for wear of rubbing surfaces in microengines was developed. The root causes of failure for operating and non-operating MEMS are discussed. The major failure mechanism for operating MEMS was wear of the polysilicon rubbing surfaces. Reliability design rules for future MEMS devices are established.

  2. Detection of intra-cardiac thrombi and congestive heart failure in cats using computed tomographic angiography.

    Science.gov (United States)

    Vititoe, Kyle P; Fries, Ryan C; Joslyn, Stephen; Selmic, Laura E; Howes, Mark; Vitt, Jordan P; O'Brien, Robert T

    2018-04-16

    Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure. © 2018 American College of Veterinary Radiology.

  3. Operation safety of complex industrial systems. Main concepts

    International Nuclear Information System (INIS)

    Zwingelstein, G.

    2009-01-01

    Operation safety consists in knowing, evaluating, foreseeing, measuring and mastering the technological system and human failures in order to avoid their impacts on health and people's safety, on productivity, and on the environment, and to preserve the Earth's resources. This article recalls the main concepts of operation safety: 1 - evolutions in the domain; 2 - failures, missions and functions of a system and of its components: functional failure, missions and functions, industrial processes, notions of probability; 3 - basic concepts and operation safety: reliability, unreliability, failure density, failure rate, relations between them, availability, maintainability, safety. (J.S.)

  4. Methodical treatment of dependent failures in risk analyses

    International Nuclear Information System (INIS)

    Hennings, W.; Mertens, J.

    1987-06-01

    In this report the state-of-the-art regarding dependent failures is compiled and commented on. Among others the following recommendations are infered: The term 'common mode failures' should be restricted to failures of redundant, similar components; the generic term is 'dependent failures' with the subsets 'causal failures' and 'common cause failures'. In risk studies, dependent failures should be covered as far as possible by 'explicit methods'. Nevertheless an uncovered rest remains, which should be accounted for by sensitivity analyses using 'implicit methods'. For this the homogeneous Marshall-Olkin model is recommended. Because the available reports on operating experiences only record 'common mode failures' systematically, it is recommended to additionally apply other methods, e.g. carry out a 'precursor study'. (orig.) [de

  5. Operation of Finnish nuclear power plants

    International Nuclear Information System (INIS)

    Tossavainen, K.

    1991-08-01

    In the Quarterly Reports on the operation of the Finnish nuclear power plants such events and observations are described relating to nuclear and radiation safety which the Finnish Centre for Radiation and Nuclear Safety considers safety significant. Also other events of general interest are reported. The report also includes a summary of the radiation safety of the plants' workers and the environment, as well as tabulated data on the production and load factors of the plants. The Finnish nuclear power plant units Loviisa 1 and 2 as well as TVO I and II were in commercial operation during the whole first quarter of 1991. The load factor average was 99.1 %. Failures have been detected in the uppermost spacing lattices of nuclear fuel bundles removed from the Loviisa nuclear reactors. Further investigations into the significance of the failures have been initiated. In this quarter, renewed cooling systems for the instrumentation area were introduced at Loviisa 1. The modifications made in the systems serve to ensure reliable cooling of the area even during the hottest summer months when the possibility exists that the temperature of the automation equipment could rise too high causing malfunctions which could endanger plant safety. Occupational radiation doses and external releases of radioactivity were below prescribed limits in this quarter. Only small amounts of radioactive substances originating in nuclear power plants were detected in samples taken in the vicinity of nuclear power plants

  6. Sequential decision reliability concept and failure rate assessment

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1990-11-01

    Conventionally, a reliability concept is considered together with both each basic unit and their integration in a complicated large scale system such as a nuclear power plant (NPP). Basically, as the plant's operational status is determined by the information obtained from various sensors, the plant's reliability and the risk assessment is closely related to the reliability of the sensory information and hence the sensor components. However, considering the relevant information-processing systems, e.g. fault detection processors, there exists a further question about the reliability of such systems, specifically the reliability of the systems' decision-based outcomes by means of which the further actions are performed. To this end, a general sequential decision reliability concept and the failure rate assessment methodology is introduced. The implications of the methodology are investigated and the importance of the decision reliability concept in system operation is demonstrated by means of sensory signals in real-time from the Borssele NPP in the Netherlands. (author). 21 refs.; 8 figs

  7. Dependent failure analysis of NPP data bases

    International Nuclear Information System (INIS)

    Cooper, S.E.; Lofgren, E.V.; Samanta, P.K.; Wong Seemeng

    1993-01-01

    A technical approach for analyzing plant-specific data bases for vulnerabilities to dependent failures has been developed and applied. Since the focus of this work is to aid in the formulation of defenses to dependent failures, rather than to quantify dependent failure probabilities, the approach of this analysis is critically different. For instance, the determination of component failure dependencies has been based upon identical failure mechanisms related to component piecepart failures, rather than failure modes. Also, component failures involving all types of component function loss (e.g., catastrophic, degraded, incipient) are equally important to the predictive purposes of dependent failure defense development. Consequently, dependent component failures are identified with a different dependent failure definition which uses a component failure mechanism categorization scheme in this study. In this context, clusters of component failures which satisfy the revised dependent failure definition are termed common failure mechanism (CFM) events. Motor-operated valves (MOVs) in two nuclear power plant data bases have been analyzed with this approach. The analysis results include seven different failure mechanism categories; identified potential CFM events; an assessment of the risk-significance of the potential CFM events using existing probabilistic risk assessments (PRAs); and postulated defenses to the identified potential CFM events. (orig.)

  8. Development and Evaluation of Algorithms to Improve Small- and Medium-Size Commercial Building Operations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woohyun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lutes, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Small- and medium-sized (<100,000 sf) commercial buildings (SMBs) represent over 95% of the U.S. commercial building stock and consume over 60% of total site energy consumption. Many of these buildings use rudimentary controls that are mostly manual, with limited scheduling capability, no monitoring or failure management. Therefore, many of these buildings are operated inefficiently and consume excess energy. SMBs typically utilize packaged rooftop units (RTUs) that are controlled by an individual thermostat. There is increased urgency to improve the operating efficiency of existing commercial building stock in the U.S. for many reasons, chief among them is to mitigate the climate change impacts. Studies have shown that managing set points and schedules of the RTUs will result in up to 20% energy and cost savings. Another problem associated with RTUs is short-cycling, where an RTU goes through ON and OFF cycles too frequently. Excessive cycling can lead to excessive wear and lead to premature failure of the compressor or its components. The short cycling can result in a significantly decreased average efficiency (up to 10%), even if there are no physical failures in the equipment. Also, SMBs use a time-of-day scheduling is to start the RTUs before the building will be occupied and shut it off when unoccupied. Ensuring correct use of the zone set points and eliminating frequent cycling of RTUs thereby leading to persistent building operations can significantly increase the operational efficiency of the SMBs. A growing trend is to use low-cost control infrastructure that can enable scalable and cost-effective intelligent building operations. The work reported in this report describes three algorithms for detecting the zone set point temperature, RTU cycling rate and occupancy schedule detection that can be deployed on the low-cost infrastructure. These algorithms only require the zone temperature data for detection. The algorithms have been tested and validated using

  9. Correct the Coagulopathy and Scoop It Out: Complete Reversal of Anuric Renal Failure through the Operative Decompression of Extraperitoneal Hematoma-Induced Abdominal Compartment Syndrome

    Directory of Open Access Journals (Sweden)

    Paul B. McBeth

    2012-01-01

    Full Text Available We report two cases of extraperitoneal compression of the intra-abdominal space resulting in abdominal compartment syndrome (ACS with overt renal failure, which responded to operative decompression of the extra-peritoneal spaces. This discussion includes patient presentation, clinical course, diagnosis, interventions, and outcomes. Data was collected from the patient’s electronic medical record and a radiology database. ACS appears to be a rare but completely reversible complication of both retroperitoneal hematoma (RH and rectus sheath hematoma (RSH. In patients with large RH or RSH consideration of intra-abdominal pressure (IAP monitoring combined with aggressive operative drainage after correction of the coagulopathy should be considered. These two cases illustrate how a relatively benign pathology can result in increased IAP, organ failure, and ultimately ACS. Intervention with decompressive laparotomy and evacuation of clot resulted in return to normal physiologic function.

  10. Defense against common-mode failures in protection system design

    International Nuclear Information System (INIS)

    Wyman, R.H.; Johnson, G.L.

    1998-01-01

    The introduction of digital instrumentation and control into reactor safety systems creates a heightened concern about common-mode failure. This paper discusses the concern and methods of cope with the concern. Common-mode failures have been a 'fact-of-life' in existing systems. The informal introduction of defense-in-depth and diversity (D-in-D and D) - coupled with the fact that hardware common-mode failures are often distributed in time - has allowed systems to deal with past common-mode failures. However, identical software operating in identical redundant systems presents the potential for simultaneous failure. Consequently, the use of digital systems raises the concern about common-mode failure to a new level. A more methodical approach to mitigating common-mode failure is needed to address these concerns. Purposeful introduction of D-in-D and D has been used as a defense against common-mode failure in reactor protection systems. At least two diverse systems are provided to mitigate any potential initiating event. Additionally, diverse displays and controls are provided to allow the operator to monitor plant status and manually initiate engineered safety features. A special form of common-mode failure analysis called 'defense-in-depth and diversity analysis' has been developed to identify possible common-mode failure vulnerabilities in digital systems. An overview of this analysis technique is provided. (author)

  11. Defense against common-mode failures in protection system design

    International Nuclear Information System (INIS)

    Wyman, R.H.; Johnson, G.L.

    1997-01-01

    The introduction of digital instrumentation and control into reactor safety systems creates a heightened concern about common-mode failure. This paper discusses the concern and methods to cope with the concern. Common-mode failures have been a ''fact-of-life'' in existing systems. The informal introduction of defense-in-depth and diversity (D-in-D ampersand D)-coupled with the fact that hardware common-mode failures are often distributed in time-has allowed systems to deal with past common-mode failures. However, identical software operating in identical redundant systems presents the potential for simultaneous failure. Consequently, the use of digital systems raises the concern about common-mode failure to a new level. A more methodical approach to mitigating common-mode failure is needed to address these concerns. Purposeful introduction of D-in-D ampersand D has been used as a defense against common-mode failure in reactor protection systems. At least two diverse systems are provided to mitigate any potential initiating event. Additionally, diverse displays and controls are provided to allow the operator to monitor plant status and manually initiate engineered safety features. A special form of conimon-mode failure analysis called ''defense-in-depth and diversity analysis'' has been developed to identify possible conimon-mode failure vulnerabilities in digital systems. An overview of this analysis technique is provided

  12. Creep-Fatigue Failure Diagnosis

    Science.gov (United States)

    Holdsworth, Stuart

    2015-01-01

    Failure diagnosis invariably involves consideration of both associated material condition and the results of a mechanical analysis of prior operating history. This Review focuses on these aspects with particular reference to creep-fatigue failure diagnosis. Creep-fatigue cracking can be due to a spectrum of loading conditions ranging from pure cyclic to mainly steady loading with infrequent off-load transients. These require a range of mechanical analysis approaches, a number of which are reviewed. The microstructural information revealing material condition can vary with alloy class. In practice, the detail of the consequent cracking mechanism(s) can be camouflaged by oxidation at high temperatures, although the presence of oxide on fracture surfaces can be used to date events leading to failure. Routine laboratory specimen post-test examination is strongly recommended to characterise the detail of deformation and damage accumulation under known and well-controlled loading conditions to improve the effectiveness and efficiency of failure diagnosis. PMID:28793676

  13. Train integrity detection risk analysis based on PRISM

    Science.gov (United States)

    Wen, Yuan

    2018-04-01

    GNSS based Train Integrity Monitoring System (TIMS) is an effective and low-cost detection scheme for train integrity detection. However, as an external auxiliary system of CTCS, GNSS may be influenced by external environments, such as uncertainty of wireless communication channels, which may lead to the failure of communication and positioning. In order to guarantee the reliability and safety of train operation, a risk analysis method of train integrity detection based on PRISM is proposed in this article. First, we analyze the risk factors (in GNSS communication process and the on-board communication process) and model them. Then, we evaluate the performance of the model in PRISM based on the field data. Finally, we discuss how these risk factors influence the train integrity detection process.

  14. A review of historical check valve failure data

    International Nuclear Information System (INIS)

    Casada, D.A.; Todd, M.D.

    1992-01-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost, and decreased system availability. In response, additional attention has been given to check valves by utilities, as well as the US Nuclear Regulatory Commission (NRC) and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient of an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. Oak Ridge National Laboratory is currently conducting a detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are being considered during the review, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions. This work is being carried out under the auspices of the NRC's Nuclear Plant Aging Research program. At this time, the study is approximately 50% complete. All failure records have been reviewed and categorized, and preliminary tabulation and correlation of data is underway. The bulk of the tabulation and correlation portion of the work is expected to be completed by the end of June 1992. A report draft is expected in the fall of 1992

  15. Pump shaft failures - a compendium of case studies

    CSIR Research Space (South Africa)

    Bernt, F

    2001-04-01

    Full Text Available During operation, pump shafts usually suffer from degradation as a result of corrosion and/or mechanical degradation, usually in the form of fatigue failures. In many cases corrosion precedes fatigue failure and can actually accelerate the rate...

  16. Operation of the water-to-sodium leak detection system at the experimental breeder reactor II

    International Nuclear Information System (INIS)

    Osterhout, M.M.

    1978-01-01

    A water-to-sodium leak detection system was installed at the Experimental Breeder Reactor II in April 1975. The system is designed for early detection of steam generator leaks, using hydrogen meters at the sodium outlets of the evaporators and superheaters. The leak detectors operate by measuring the rate of diffusion of hydrogen from the liquid sodium through a nickel membrane into a dynamic vacuum system. The advantages of this detection system are rapid response time, high sensitivity, stability, and reliability. The system was operated on an experimental basis for the first two years. During this period, data were obtained on detector stability, reliability, maintenance needs, computer interface requirements, calibration, and background hydrogen-level fluctuations. A generic defect in the original detectors was also discovered, requiring redesign of the units. When the new units were installed and proven to be reliable, the system was made fully operational. The data from the hydrogen meters are now used as the primary basis for detection of water-to-sodium leaks

  17. Hunterston A: first sixteen years of operation

    International Nuclear Information System (INIS)

    Dominey, J.R.; Battle, T.A.; Brow, N.J.; Laing, D.; Leary, D.E.

    1981-01-01

    Construction of Hunterston A was started in 1957. Commissioning of both reactors was completed in 1964, and since that date the Station has achieved a life-time load factor of 82.2% based on the original design output of 300MWe sent out. The identification in 1968 of enhanced oxidation rates of certain mild steels in CO 2 at temperatures in excess of 360 0 C led to the decision to operate the reactors at gas outlet temperatures of 360 0 C to maximise reactor component life. A fractured burst cartridge detection pipe was discovered in 1968 during reactor internal photographic surveys. Other problems encountered during the 16 years include 70 fuel element failures from 1964 to date and a number of internal boiler tube failures which occurred between 1964 and 1968. (U.K.)

  18. EBR-II water-to-sodium leak detection system

    International Nuclear Information System (INIS)

    Wrightson, M.M.; McKinley, K.; Ruther, W.E.; Holmes, J.T.

    1976-01-01

    The water-to-sodium leak detection system installed at EBR-II in April, 1975, is described in detail. Topics covered include operational characteristics, maintenance problems, alarm functions, background hydrogen level data, and future plans for refinements to the system. Particular emphasis is given to the failures of eight of the ten leak detectors due to sodium-to-vacuum leakage, and the program anticipated for complete recovery of the system

  19. Second date appendectomy: Operating for failure of nonoperative treatment in perforated appendicitis.

    Science.gov (United States)

    Lotti, Marco

    2017-06-01

    Nonoperative treatment of acute appendicitis is embraced by many surgical teams, driven by low to moderate quality randomized studies that support noninferiority of antibiotics versus appendectomy for treatment of acute uncomplicated appendicitis. Several flaws of these studies have emerged, especially in the recruitment strategy and in the diagnostic criteria that were used. The growing confidence given to antibiotics, together with the lack of reliable criteria to distinguish between uncomplicated and perforated appendicitis, exposes patients with perforated appendicitis to the likelihood to be treated with antibiotics instead of surgery. Among them, those patients who experience a temporary relief of symptoms due to antibiotics, followed by early recurrence of disease when antibiotics are discontinued, are likely to undergo appendectomy at their second date. Second date appendectomy, i.e. the removal of the appendix when acute inflammation relapses within the scar of a previously unhealed perforated appendicitis, is the unwanted child of the nonoperative treatment and a new challenge for both the surgeon and the patient. Between June and July 2016, two patients were readmitted and operated for failure of nonoperative treatment with antibiotics. A video is presented, which focuses on the different anatomic presentation and technical challenges between prompt and second date laparoscopic appendectomy. When proposing nonoperative treatment for acute appendicitis, surgeons should be aware and inform their patients that if the appendix is perforated and an incomplete healing and early recurrence occur, a second date appendectomy could be a more challenging operation compared to a prompt appendectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Survey of Operators Knowledge of Operation and Maintenance of ...

    African Journals Online (AJOL)

    Result showed that the machine failures encountered during operations were as a result of poor management, inadequate maintenance practices, and lack of spare parts, obsoleteness, overloading, careless operations and poor storage of machine after use. Recommendations were therefore given to improve the operation ...

  1. The interaction of NDE and failure analysis

    International Nuclear Information System (INIS)

    Nichols, R.W.

    1988-01-01

    This paper deals with the use of Non-Destructive Examination (NDE) and failure analysis for the assessment of the structural integrity. It appears that failure analysis enables to know whether NDE is required or not, and can help to direct NDE into the most useful directions by identifying the areas where it is most important that defects are absent. It also appears that failure analysis can help the operator to decide which NDE method is best suited to the component studied and provides detailed specifications for this NDE method. The interaction between failure analysis and NDE is then described. (TEC)

  2. The interaction of NDE and failure analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, R W

    1988-12-31

    This paper deals with the use of Non-Destructive Examination (NDE) and failure analysis for the assessment of the structural integrity. It appears that failure analysis enables to know whether NDE is required or not, and can help to direct NDE into the most useful directions by identifying the areas where it is most important that defects are absent. It also appears that failure analysis can help the operator to decide which NDE method is best suited to the component studied and provides detailed specifications for this NDE method. The interaction between failure analysis and NDE is then described. (TEC).

  3. Identification of the human factors contributing to maintenance failures in a petroleum operation.

    Science.gov (United States)

    Antonovsky, Ari; Pollock, Clare; Straker, Leon

    2014-03-01

    This research aimed to identify the most frequently occurring human factors contributing to maintenance-related failures within a petroleum industry organization. Commonality between failures will assist in understanding reliability in maintenance processes, thereby preventing accidents in high-hazard domains. Methods exist for understanding the human factors contributing to accidents. Their application in a maintenance context mainly has been advanced in aviation and nuclear power. Maintenance in the petroleum industry provides a different context for investigating the role that human factors play in influencing outcomes. It is therefore worth investigating the contributing human factors to improve our understanding of both human factors in reliability and the factors specific to this domain. Detailed analyses were conducted of maintenance-related failures (N = 38) in a petroleum company using structured interviews with maintenance technicians. The interview structure was based on the Human Factor Investigation Tool (HFIT), which in turn was based on Rasmussen's model of human malfunction. A mean of 9.5 factors per incident was identified across the cases investigated.The three most frequent human factors contributing to the maintenance failures were found to be assumption (79% of cases), design and maintenance (71%), and communication (66%). HFIT proved to be a useful instrument for identifying the pattern of human factors that recurred most frequently in maintenance-related failures. The high frequency of failures attributed to assumptions and communication demonstrated the importance of problem-solving abilities and organizational communication in a domain where maintenance personnel have a high degree of autonomy and a wide geographical distribution.

  4. A study of common-mode failures

    International Nuclear Information System (INIS)

    Edwards, G.T.; Watson, I.A.

    1979-07-01

    The purpose of the report is to investigate problems of the identification of the common failure mode (CFM) the reliability models used and the data required for their solution, particularly with regard to automatic protection systems for nuclear reactors. The available literature which was surveyed during the study is quoted and used as a basis for the main work of the study. The type of redundancy system under consideration is initially described and the types of CFM to which these systems are prone are identified before a general definition of the term 'common mode failure' is proposed. The definition and proposed classification system for CMF are based on the common cause of failure, so identifying the primary events. Defences against CFM are included and proposals for an overall strategy and detailed recommendations for design and operation are made. Common mode failures in US nuclear reactor systems, aircraft systems, and other sources including chemical plant systems are surveyed. The data indicates the importance of the human error problem in the causes of CMF in design, maintenance and operation. From a study of the collected data a redundancy sub-system model for CMF is developed which identifies three main categories of failure, non-recurrent engineering design errors, maintenance and test errors, and random interest events. The model proposed allows for the improvement in sub-system reliability where appropriate defences are applied. (author)

  5. Operational risk management for a NPP

    Energy Technology Data Exchange (ETDEWEB)

    Scott, C.K., E-mail: KScott@AtlanticNuclear.ca [Atlantic Nuclear Services Inc., Fredericton, New Brunswick (Canada)

    2013-07-01

    Organizational failures are a hazard to the successful operation of a nuclear power plant. Risk reduction strategies have been developed around two themes: using an understanding of the nature and mechanism of human failures to eliminate them by modifying work processes; or, modifying human behaviour by creating a strong safety culture that overrides the tendency to fail. This paper examines the problem from the perspective of operational risk management. It includes the internal management of operations and the influence of the external environment on the organization. A model is proposed that encompasses all the operational risk factors in the organization's decision making process. To prevent failure the organization must have the capability to adapt and the capacity to evolve. The hazards that would lead to an organizational failure are developed from this evolutionary model. The operational risk management program would include these hazards as well as the conventional nuclear safety hazards. (author)

  6. Probability distribution of machining center failures

    International Nuclear Information System (INIS)

    Jia Yazhou; Wang Molin; Jia Zhixin

    1995-01-01

    Through field tracing research for 24 Chinese cutter-changeable CNC machine tools (machining centers) over a period of one year, a database of operation and maintenance for machining centers was built, the failure data was fitted to the Weibull distribution and the exponential distribution, the effectiveness was tested, and the failure distribution pattern of machining centers was found. Finally, the reliability characterizations for machining centers are proposed

  7. Fault Management Techniques in Human Spaceflight Operations

    Science.gov (United States)

    O'Hagan, Brian; Crocker, Alan

    2006-01-01

    This paper discusses human spaceflight fault management operations. Fault detection and response capabilities available in current US human spaceflight programs Space Shuttle and International Space Station are described while emphasizing system design impacts on operational techniques and constraints. Preflight and inflight processes along with products used to anticipate, mitigate and respond to failures are introduced. Examples of operational products used to support failure responses are presented. Possible improvements in the state of the art, as well as prioritization and success criteria for their implementation are proposed. This paper describes how the architecture of a command and control system impacts operations in areas such as the required fault response times, automated vs. manual fault responses, use of workarounds, etc. The architecture includes the use of redundancy at the system and software function level, software capabilities, use of intelligent or autonomous systems, number and severity of software defects, etc. This in turn drives which Caution and Warning (C&W) events should be annunciated, C&W event classification, operator display designs, crew training, flight control team training, and procedure development. Other factors impacting operations are the complexity of a system, skills needed to understand and operate a system, and the use of commonality vs. optimized solutions for software and responses. Fault detection, annunciation, safing responses, and recovery capabilities are explored using real examples to uncover underlying philosophies and constraints. These factors directly impact operations in that the crew and flight control team need to understand what happened, why it happened, what the system is doing, and what, if any, corrective actions they need to perform. If a fault results in multiple C&W events, or if several faults occur simultaneously, the root cause(s) of the fault(s), as well as their vehicle-wide impacts, must be

  8. FAILURE MODE AND EFFECT ANALYSIS (FMEA OF BUTTERFLY VALVE IN OIL AND GAS INDUSTRY

    Directory of Open Access Journals (Sweden)

    MUHAMMAD AMIRUL BIN YUSOF

    2016-04-01

    Full Text Available Butterfly valves are mostly used in various industries such as oil and gas plant. This valve operates with rotating motion using pneumatic system. Rotating actuator turns the disc either parallel or perpendicular to the flow. When the valve is fully open, the disc is rotated a quarter turn so that it allows free passage of the fluid and when fully closed, the disc rotated a quarter turns to block the fluid. The primary failure modes for valves are the valve leaks to environment through flanges, seals on the valve body, valve stem packing not properly protected, over tightened packing nuts, the valve cracks and leaks over the seat. To identify the failure of valve Failure Mode and Effects Analysis has been chosen. FMEA is the one of technique to perform failure analysis. It involves reviewing as many components to identify failure modes, and their causes and effects. For each component, the failure modes and their resulting effects on the rest of the system are recorded in a specific FMEA form. Risk priority number, severity, detection, occurrence are the factor determined in this studies. Risk priority number helps to find out the highest hazardous activities which need more attention than the other activity. The highest score of risk priority number in this research is seat. Action plan was proposed to reduce the risk priority number and so that potential failures also will be reduced.

  9. Palliative Care in Heart Failure

    Directory of Open Access Journals (Sweden)

    Hatice Mert

    2012-04-01

    Full Text Available Heart failure is an important health problem since its incidence and prevalence is increasing year by year. Since symptom burden and mortality are high in heart failure, supportive and palliative care should be provided. However, very few patients are referred to palliative care services. In comparison with cancer patients, it is difficult to identify end of life care for patients with heart failure, because these patients are hospitalized when the signs of acute decompensation appear, and their symptoms decrease and functional status improve before they are discharged. Therefore, palliative care, which is a holistic approach aiming to improve patients’ quality of life, to detect and treat the attacks of the disease before they become severe, and to deal with patients’ physical, psychological, social, and mental health altogether during their care, should be integrated into heart failure patients’ care. [TAF Prev Med Bull 2012; 11(2.000: 217-222

  10. Characterization of ultrathin insulators in CMOS technology: Wearout and failure mechanisms due to processing and operation

    Science.gov (United States)

    Okandan, Murat

    In the CMOS technology the gate dielectric is the most critical layer, as its condition directly dictates the ultimate performance of the devices. In this thesis, the wear-out and failure mechanisms in ultra-thin (around 50A and lower) oxides are investigated. A new degradation phenomenon, quasi-breakdown (or soft-breakdown), and the annealing and stressing behavior of devices after quasi-breakdown are considered in detail. Devices that are in quasi-breakdown continue to operate as switches, but the gate leakage current is two orders of magnitude higher than the leakage in healthy devices and the stressing/annealing behavior of the devices are completely altered. This phenomenon is of utmost interest, since the reduction in SiO2 dielectric thickness has reached its physical limits, and the quasi-breakdown behavior is seen to dominate as a failure mode in this regime. The quasi-breakdown condition can be brought on by stresses during operation or processing. To further study this evolution through stresses and anneals, cyclic current-voltage (I-V) measurement has been further developed and utilized in this thesis. Cyclic IV is a simple and fast, two terminal measurement technique that looks at the transient current flowing in an MOS system during voltage sweeps from accumulation to inversion and back. During these sweeps, carrier trapping/detrapping, generation and recombination are observed. An experimental setup using a fast electrometer and analog to digital conversion (A/D) card and the software for control of the setup and data analysis were also developed to gain further insight into the detailed physics involved. Overall, the crucial aspects of wear-out and quasi-breakdown of ultrathin dielectrics, along with the methods for analyzing this evolution are presented in this thesis.

  11. Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    Power electronics plays an important role in a wide range of applications in order to achieve high efficiency and performance. Increasing efforts are being made to improve the reliability of power electronics systems to ensure compliance with more stringent constraints on cost, safety......, and availability in different applications. This paper presents an overview of the major failure mechanisms of IGBT modules and their handling methods in power converter systems improving reliability. The major failure mechanisms of IGBT modules are presented first, and methods for predicting lifetime...... and estimating the junction temperature of IGBT modules are then discussed. Subsequently, different methods for detecting open- and short-circuit faults are presented. Finally, fault-tolerant strategies for improving the reliability of power electronic systems under field operation are explained and compared...

  12. Innovative Telemonitoring System for Cardiology: From Science to Routine Operation

    Science.gov (United States)

    Kastner, P.; Morak, J.; Modre, R.; Kollmann, A.; Ebner, C.; Fruhwald, FM.; Schreier, G.

    2010-01-01

    Objective Results of the Austrian MOBITEL (MOBIle phone based TELemonitoring for heart failure patients) trial indicate that home-based telemonitoring improves outcome of chronic heart failure (CHF) patients and reduces both frequency and duration of hospitalizations. Based on lessons learned, we assessed the weak points to clear the way for routine operations. Methods We analyzed the system with respect to recommendations of the ESC Guidelines and experiences gained throughout the trial to identify potential improvements. The following components have been identified: a patient terminal with highest usability, integrated way to document drug-intake and well-being, and automated event detection for worsening of CHF. As a consequence the system was extended by Near Field Communication (NFC) technology and by an event management tool. Results Usability evaluation with 30 adults (14f, median 51y. IQR[45-65]) showed that 21 (8f) were able to immediately operate the system after reading a step-by-step manual. Eight (6f) needed one time demonstration and one man (80y) failed to operate the blood pressure meter. Routine operation of the revised system started in March 2009. Within 9 months, 15 patients (4f, median 74y. IQR[71-83], all NYHA-III) transmitted 17,149 items. 43 events were detected because of body weight gain of more then 2kg within 2 days. 49 therapy adjustments were documented. Three patients stopped using the system, two (1f) because of non-compliance and one (m, 82y) because of death. Overall, the rate of adherence to daily data transfer was 78%. Conclusion First results confirm the applicability of the revised telemonitoring system in routine operation. PMID:23616835

  13. Improving the performance of univariate control charts for abnormal detection and classification

    Science.gov (United States)

    Yiakopoulos, Christos; Koutsoudaki, Maria; Gryllias, Konstantinos; Antoniadis, Ioannis

    2017-03-01

    Bearing failures in rotating machinery can cause machine breakdown and economical loss, if no effective actions are taken on time. Therefore, it is of prime importance to detect accurately the presence of faults, especially at their early stage, to prevent sequent damage and reduce costly downtime. The machinery fault diagnosis follows a roadmap of data acquisition, feature extraction and diagnostic decision making, in which mechanical vibration fault feature extraction is the foundation and the key to obtain an accurate diagnostic result. A challenge in this area is the selection of the most sensitive features for various types of fault, especially when the characteristics of failures are difficult to be extracted. Thus, a plethora of complex data-driven fault diagnosis methods are fed by prominent features, which are extracted and reduced through traditional or modern algorithms. Since most of the available datasets are captured during normal operating conditions, the last decade a number of novelty detection methods, able to work when only normal data are available, have been developed. In this study, a hybrid method combining univariate control charts and a feature extraction scheme is introduced focusing towards an abnormal change detection and classification, under the assumption that measurements under normal operating conditions of the machinery are available. The feature extraction method integrates the morphological operators and the Morlet wavelets. The effectiveness of the proposed methodology is validated on two different experimental cases with bearing faults, demonstrating that the proposed approach can improve the fault detection and classification performance of conventional control charts.

  14. Failure Diagnosis System for a Ball-Screw by Using Vibration Signals

    Directory of Open Access Journals (Sweden)

    Won Gi Lee

    2015-01-01

    Full Text Available Recently, in order to reduce high maintenance costs and to increase operating ratio in manufacturing systems, condition-based maintenance (CBM has been developed. CBM is carried out with indicators, which show equipment’s faults and performance deterioration. In this study, indicator signal acquisition and condition monitoring are applied to a ball-screw-driven stage. Although ball-screw is a typical linearly reciprocating part and is widely used in industry, it has not gained attention to be diagnosed compared to rotating parts such as motor, pump, and bearing. First, the vibration-based monitoring method, which uses vibration signal to monitor the condition of a machine, is proposed. Second, Wavelet transform is used to analyze the defect signals in time-frequency domain. Finally, the failure diagnosis system is developed using the analysis, and then its performance is evaluated. Using the system, we estimated the severity of failure and detect the defect position. The low defect frequency (≈58.7 Hz is spread all over the time in the Wavelet-filtered signal with low frequency range. Its amplitude reflects the progress of defect. The defect position was found in the signal with high frequency range (768~1,536 Hz. It was detected from the interval between abrupt changes of signal.

  15. Level of Automation and Failure Frequency Effects on Simulated Lunar Lander Performance

    Science.gov (United States)

    Marquez, Jessica J.; Ramirez, Margarita

    2014-01-01

    A human-in-the-loop experiment was conducted at the NASA Ames Research Center Vertical Motion Simulator, where instrument-rated pilots completed a simulated terminal descent phase of a lunar landing. Ten pilots participated in a 2 x 2 mixed design experiment, with level of automation as the within-subjects factor and failure frequency as the between subjects factor. The two evaluated levels of automation were high (fully automated landing) and low (manual controlled landing). During test trials, participants were exposed to either a high number of failures (75% failure frequency) or low number of failures (25% failure frequency). In order to investigate the pilots' sensitivity to changes in levels of automation and failure frequency, the dependent measure selected for this experiment was accuracy of failure diagnosis, from which D Prime and Decision Criterion were derived. For each of the dependent measures, no significant difference was found for level of automation and no significant interaction was detected between level of automation and failure frequency. A significant effect was identified for failure frequency suggesting failure frequency has a significant effect on pilots' sensitivity to failure detection and diagnosis. Participants were more likely to correctly identify and diagnose failures if they experienced the higher levels of failures, regardless of level of automation

  16. Failure analysis of a Francis turbine runner

    Energy Technology Data Exchange (ETDEWEB)

    Frunzaverde, D; Campian, V [Research Center in Hydraulics, Automation and Heat Transfer, ' Eftimie Murgu' University of Resita P-ta Traian Vuia 1-4, RO-320085, Resita (Romania); Muntean, S [Centre of Advanced Research in Engineering Sciences, Romanian Academy - Timisoara Branch Bv. Mihai Viteazu 24, RO-300223, Timisoara (Romania); Marginean, G [University of Applied Sciences Gelsenkirchen, Neidenburger Str. 10, 45877 Gelsenkirchen (Germany); Marsavina, L [Department of Strength, ' Politehnica' University of Timisoara, Bv. Mihai Viteazu 1, RO-300222, Timisoara (Romania); Terzi, R; Serban, V, E-mail: gabriela.marginean@fh-gelsenkirchen.d, E-mail: d.frunzaverde@uem.r [Ramnicu Valcea Subsidiary, S.C. Hidroelectrica S.A., Str. Decebal 11, RO-240255, Ramnicu Valcea (Romania)

    2010-08-15

    The variable demand on the energy market requires great flexibility in operating hydraulic turbines. Therefore, turbines are frequently operated over an extended range of regimes. Francis turbines operating at partial load present pressure fluctuations due to the vortex rope in the draft tube cone. This phenomenon generates strong vibrations and noise that may produce failures on the mechanical elements of the machine. This paper presents the failure analysis of a broken Francis turbine runner blade. The failure appeared some months after the welding repair work realized in situ on fatigue cracks initiated near to the trailing edge at the junction with the crown, where stress concentration occurs. In order to determine the causes that led to the fracture of the runner blade, the metallographic investigations on a sample obtained from the blade is carried out. The metallographic investigations included macroscopic and microscopic examinations, both performed with light and scanning electron microscopy, as well as EDX - analyses. These investigations led to the conclusion, that the cracking of the blade was caused by fatigue, initiated by the surface unevenness of the welding seam. The failure was accelerated by the hydrogen embrittlement of the filling material, which appeared as a consequence of improper welding conditions. In addition to the metallographic investigations, numerical computations with finite element analysis are performed in order to evaluate the deformation and stress distribution on blade.

  17. Failure analysis of a Francis turbine runner

    International Nuclear Information System (INIS)

    Frunzaverde, D; Campian, V; Muntean, S; Marginean, G; Marsavina, L; Terzi, R; Serban, V

    2010-01-01

    The variable demand on the energy market requires great flexibility in operating hydraulic turbines. Therefore, turbines are frequently operated over an extended range of regimes. Francis turbines operating at partial load present pressure fluctuations due to the vortex rope in the draft tube cone. This phenomenon generates strong vibrations and noise that may produce failures on the mechanical elements of the machine. This paper presents the failure analysis of a broken Francis turbine runner blade. The failure appeared some months after the welding repair work realized in situ on fatigue cracks initiated near to the trailing edge at the junction with the crown, where stress concentration occurs. In order to determine the causes that led to the fracture of the runner blade, the metallographic investigations on a sample obtained from the blade is carried out. The metallographic investigations included macroscopic and microscopic examinations, both performed with light and scanning electron microscopy, as well as EDX - analyses. These investigations led to the conclusion, that the cracking of the blade was caused by fatigue, initiated by the surface unevenness of the welding seam. The failure was accelerated by the hydrogen embrittlement of the filling material, which appeared as a consequence of improper welding conditions. In addition to the metallographic investigations, numerical computations with finite element analysis are performed in order to evaluate the deformation and stress distribution on blade.

  18. Ambition to reach zero level failure in VVER 1000 with russian fuel

    International Nuclear Information System (INIS)

    Mečíř, V.

    2015-01-01

    The purpose of “The Zero Failure Level Project” is to bring to real operation of VVER 1000 units the dream of all utilities such as problem free and cost effective operation. This essentially turns into requirement on failure free fuel operation. At the same time the general requirements such as safety, cost effectiveness, operational flexibility, fuel cycle and fuel flexibility need to be satisfied. Several specific tasks were performed and many of them are still in process. Specific failure tree was developed in a format, which allows step by step failure tree improvement. Fuel types and its modifications, taking into account manufacturing conditions, were specified. In parallel with fuel types classification, real operational conditions were evaluated based on approximately 280 parameters by fuel assembly design features, operational procedures and practices and about 250 reactor unit parameters. As a result of this stage, groups of units with similar fuel operational conditions should be revealed and experience sharing database created. It is also recognized a need for consistent methods of operational data and data from pool side fuel assembly inspection. In the area of Foreign Material Exclusion activities closer cooperation between utility and supplier should be established including foreign material classification and improvement in root cause investigation

  19. Aberrant GSTP1 promoter methylation predicts short-term prognosis in acute-on-chronic hepatitis B liver failure.

    Science.gov (United States)

    Gao, S; Sun, F-K; Fan, Y-C; Shi, C-H; Zhang, Z-H; Wang, L-Y; Wang, K

    2015-08-01

    Glutathione-S-transferase P1 (GSTP1) methylation has been demonstrated to be associated with oxidative stress induced liver damage in acute-on-chronic hepatitis B liver failure (ACHBLF). To evaluate the methylation level of GSTP1 promoter in acute-on-chronic hepatitis B liver failure and determine its predictive value for prognosis. One hundred and five patients with acute-on-chronic hepatitis B liver failure, 86 with chronic hepatitis B (CHB) and 30 healthy controls (HC) were retrospectively enrolled. GSTP1 methylation level in peripheral mononuclear cells (PBMC) was detected by MethyLight. Clinical and laboratory parameters were obtained. GSTP1 methylation levels were significantly higher in patients with acute-on-chronic hepatitis B liver failure (median 16.84%, interquartile range 1.83-59.05%) than those with CHB (median 1.25%, interquartile range 0.48-2.47%; P chronic hepatitis B liver failure group, nonsurvivors showed significantly higher GSTP1 methylation levels (P chronic hepatitis B liver failure, GSTP1 methylation showed significantly better predictive value than MELD score [area under the receiver operating characteristic curve (AUC) 0.89 vs. 0.72, P chronic hepatitis B liver failure and shows high predictive value for short-term mortality. It might serve as a potential prognostic marker for acute-on-chronic hepatitis B liver failure. © 2015 John Wiley & Sons Ltd.

  20. Miracle on the Vistula: The Red Army’s Failure and the Birth of the Deep Operations Theory of Annihilation

    Science.gov (United States)

    2017-04-09

    Miracle on the Vistula: The Red Army’s Failure and the Birth of the Deep Operations Theory of Annihilation A Monograph by MAJ Charles E. Thompson...United States Army School of Advanced Military Studies United States Army Command and General Staff College Fort Leavenworth, Kansas 2017...collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT

  1. The likelihood of failures in the operation of the mechanism of movement of a cargo truck electrical hook bridge crane

    Directory of Open Access Journals (Sweden)

    Ritenman I.L.

    2018-03-01

    Full Text Available Given the application of the methods of analysis of types and consequences of failures (FMEA analysis to assess the technical risk of occurrence of emergency situations during the operation of the lifting mechanism electrical hook bridge crane. The technique allows to identify the limiting elements and to determine the significance of effects in the design of the lifting mechanism, to develop measures to reduce the risk of the occurrence of an emergency.

  2. The likelihood of failures in the operation of the mechanism of movement of a cargo truck electrical hook bridge crane

    Directory of Open Access Journals (Sweden)

    Ritenman I.L.

    2017-12-01

    Full Text Available Given the application of the methods of analysis of types and consequences of failures (FMEA analysis to assess the technical risk of occurrence of emergency situations during the operation of the lifting mechanism electrical hook bridge crane. The technique allows to identify the limiting elements and to determine the significance of effects in the design of the lifting mechanism, to develop measures to reduce the risk of the occurrence of an emergency.

  3. Diagnosis of Heat Exchanger Tube Failure in Fossil Fuel Boilers Through Estimation of Steady State Operating Conditions

    International Nuclear Information System (INIS)

    Herszage, A.; Toren, M.

    1998-01-01

    Estimation of operating conditions for fossil fuel boiler heat exchangers is often required due to changes in working conditions, design modifications and especially for monitoring performance and failure diagnosis. Regular heat exchangers in fossil fuel boilers are composed of tube banks through which water or steam flow, while hot combustion (flue) gases flow outside the tubes. This work presents a top-down approach to operating conditions estimation based on field measurements. An example for a 350 MW unit superheater is thoroughly discussed. Integral calculations based on measurements for all unit heat exchangers (reheaters, superheaters) were performed first. Based on these calculations a scheme of integral conservation equations (lumped parameter) was then formulated at the single tube level. Steady state temperatures of superheater tube walls were obtained as a main output, and were compared to the maximum allowable operating temperatures of the tubes material. A combined lumped parameter - CFD (Computational Fluid Dynamics, FLUENT code) approach constitutes an efficient tool in certain cases. A brief report of such a case is given for another unit superheater. We conclude that steady state evaluations based on both integral and detailed simulations are a valuable monitoring and diagnosis tool for the power generation industry

  4. Motor current signature analysis for determining operational readiness of motor-operated valves (MOVs)

    International Nuclear Information System (INIS)

    Kryter, R.C.; Haynes, H.D.

    1987-01-01

    Motor current signature analysis (MCSA) is a novel diagnostic process for condition monitoring of electric-motor-driven mechanical equipment (e.g., pumps, motor-operated valves, compressors, and processing machinery). The MCSA process identifies, characterizes, and trends over time the instantaneous load variations of mechanical equipment in order to diagnose changes in the condition of the equipment (e.g., due to degradation or service wear), which, if allowed to continue, may lead to failure. It monitors the instantaneous variations (noise content) in the electric current flowing through the power leads to the electric motor that drives the equipment. The motor itself thereby acts as a transducer, sensing both large and small, long-term and rapid, mechanical load variations and converting them to variations in the induced current generated in the motor windings. This motor current noise signature is detected, amplified, and further processed as needed to examine its time domain and frequency domain (spectral) characteristics. The operational principles of MCSA and the nonintrusive data collection apparatus and procedure used with MOVs will be described. Data collected from MOVs in both laboratory and in-plant environments will also be shown to illustrate the ability of MCSA to ''see'' the detailed inner workings of the valve and operator and thus to detect degraded performance at an incipient stage. (Set of 18 vugraphs)

  5. Transient leak detection in crude oil pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Beushausen, R.; Tornow, S.; Borchers, H. [Nord-West Oelleitung, Wilhelmshaven (Germany); Murphy, K.; Zhang, J. [Atmos International Ltd., Manchester (United Kingdom)

    2004-07-01

    Nord-West Oelleitung (NWO) operates 2 crude oil pipelines from Wilhemshaven to Koln and Hamburg respectively. German regulations for transporting flammable substances stipulate that 2 independent continuously working procedures be used to detect leaks. Leak detection pigs are used routinely to complement the surveillance system. This paper described the specific issues of transient leak detection in crude oil pipelines. It was noted that traditional methods have failed to detect leaks that occur immediately after pumps are turned on or off because the pressure wave generated by the transient dominates the pressure wave that results from the leak. Frequent operational changes in a pipeline are often accompanied by an increased number of false alarms and failure to detect leaks due to unsteady operations. NWO therefore decided to have the Atmos statistical pipeline leak detection (SPLD) system installed on their pipelines. The key to the SPLD system is the sequential probability ratio test. Comprehensive data validation is performed following reception of pipeline data from the supervisory control and data acquisition (SCADA) system. The validated data is then used to calculate the corrected flow imbalance, which is fed into the SPRT to determine if there is an increase in the flow imbalance. Pattern recognition is then used to distinguish a leak from operational changes. The SPLD is unique because it uses 3 computational pipeline monitoring methods simultaneously, namely modified volume balance, statistical analysis, and pressure and flow monitoring. The successful installation and testing of the SPLD in 2 crude oil pipelines was described along with the main difficulties associated with transient leaks. Field results were presented for both steady-state and transient conditions. 5 refs., 2 tabs., 16 figs.

  6. [Orthognathic surgery: surgical failures and complications].

    Science.gov (United States)

    Guyot, Laurent

    2016-03-01

    Orthognathic surgery procedures mark the endpoint of lengthy orthodontic-surgical preparations and herald the completion of treatment for patients and their families. The main types of procedure are full maxillary Le Fort I osteotomies, mandibular osteotomies and chin surgery. To ensure a successful outcome, all require a favorable environment and extreme technical skill. But, like all surgical operations, they are also subject to peri- and post-operative complications resulting from treatment hazards or errors. Whatever the cause, surgical complications can entail failures in the management of the malformation. By seeking to understand and analyzing these complications, we can already help to prevent and reduce the contingent risks of failure. © EDP Sciences, SFODF, 2016.

  7. Health market failures: Colombian case

    Directory of Open Access Journals (Sweden)

    Javier Eduardo Bejarano-Daza

    2017-01-01

    Conclusion: There are significant failures in the Colombian health market which make the system inefficient and inequitable; this situation demands for reconsideration of an economic model for financing and operation under a new paradigm.

  8. Optimization of Second Fault Detection Thresholds to Maximize Mission POS

    Science.gov (United States)

    Anzalone, Evan

    2018-01-01

    In order to support manned spaceflight safety requirements, the Space Launch System (SLS) has defined program-level requirements for key systems to ensure successful operation under single fault conditions. To accommodate this with regards to Navigation, the SLS utilizes an internally redundant Inertial Navigation System (INS) with built-in capability to detect, isolate, and recover from first failure conditions and still maintain adherence to performance requirements. The unit utilizes multiple hardware- and software-level techniques to enable detection, isolation, and recovery from these events in terms of its built-in Fault Detection, Isolation, and Recovery (FDIR) algorithms. Successful operation is defined in terms of sufficient navigation accuracy at insertion while operating under worst case single sensor outages (gyroscope and accelerometer faults at launch). In addition to first fault detection and recovery, the SLS program has also levied requirements relating to the capability of the INS to detect a second fault, tracking any unacceptable uncertainty in knowledge of the vehicle's state. This detection functionality is required in order to feed abort analysis and ensure crew safety. Increases in navigation state error and sensor faults can drive the vehicle outside of its operational as-designed environments and outside of its performance envelope causing loss of mission, or worse, loss of crew. The criteria for operation under second faults allows for a larger set of achievable missions in terms of potential fault conditions, due to the INS operating at the edge of its capability. As this performance is defined and controlled at the vehicle level, it allows for the use of system level margins to increase probability of mission success on the operational edges of the design space. Due to the implications of the vehicle response to abort conditions (such as a potentially failed INS), it is important to consider a wide range of failure scenarios in terms of

  9. ICDE project report: collection and analysis of common-cause failure of check valves

    International Nuclear Information System (INIS)

    Theiss, Klaus; Hessel, Philippe; Werner, Wolfgang

    2003-05-01

    ' were screened out for that review. The most common failure mode of CVs is 'failure to close' (includes internal leaking). Deficiencies in operation were responsible for about 50% of the failure causes, mainly due to 'deficient maintenance procedures'. In several cases test and maintenance intervals were too long, which prevent timely detection of the failure mechanism. The other 50% of failure causes were mainly due to 'deficiencies in design of hardware'. Two dominant failure symptoms have been identified: valve movement impeded by deposition of dirt or oxidation products and valve leakage due to disk/seat surface degradation. Other failure symptoms are disk/seat misalignment and problems with loose or broken piece parts. The dominant failure mechanism are mechanical wear, (in particular disk/seat surface degradation causing the valve to leak), and chemical wear (in particular corrosion products impeding valve movement)

  10. Failures and abnormalities in nuclear stations in fiscal year 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The number of failures and abnormalities reported by electric power companies to the Agency of Natural Resources and Energy based on the relevant laws was 18 cases, and decreased by 9 cases as compared with that in the previous year. Consequently, the yearly average number of accidents per one plant became 0.6, the smallest value since the start of operation of commercial reactors in 1966, and it shows that recently, the troubles have steadily decreased. The breakdown of 18 cases was 4 cases of automatic stop during operation, 3 cases of manual stop during operation, 1 case which did not affect operation, and 10 cases found in regular inspection. The main causes of the accidents and failures were classified into 1 case of improper design management, 4 cases of improper manufacture management, 2 cases of improper construction management, 9 cases of improper maintenance management and 2 other cases. In all failures and abnormalities, the effect of radioactivity to the environment surrounding nuclear power stations did not arise. Besides, 28 cases of minor failures were reported based on the notice of the Minister of International Trade and Industry. (Kako, I.)

  11. Sensor failure and multivariable control for airbreathing propulsion systems. Ph.D. Thesis - Dec. 1979 Final Report

    Science.gov (United States)

    Behbehani, K.

    1980-01-01

    A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

  12. A physical probabilistic model to predict failure rates in buried PVC pipelines

    International Nuclear Information System (INIS)

    Davis, P.; Burn, S.; Moglia, M.; Gould, S.

    2007-01-01

    For older water pipeline materials such as cast iron and asbestos cement, future pipe failure rates can be extrapolated from large volumes of existing historical failure data held by water utilities. However, for newer pipeline materials such as polyvinyl chloride (PVC), only limited failure data exists and confident forecasts of future pipe failures cannot be made from historical data alone. To solve this problem, this paper presents a physical probabilistic model, which has been developed to estimate failure rates in buried PVC pipelines as they age. The model assumes that under in-service operating conditions, crack initiation can occur from inherent defects located in the pipe wall. Linear elastic fracture mechanics theory is used to predict the time to brittle fracture for pipes with internal defects subjected to combined internal pressure and soil deflection loading together with through-wall residual stress. To include uncertainty in the failure process, inherent defect size is treated as a stochastic variable, and modelled with an appropriate probability distribution. Microscopic examination of fracture surfaces from field failures in Australian PVC pipes suggests that the 2-parameter Weibull distribution can be applied. Monte Carlo simulation is then used to estimate lifetime probability distributions for pipes with internal defects, subjected to typical operating conditions. As with inherent defect size, the 2-parameter Weibull distribution is shown to be appropriate to model uncertainty in predicted pipe lifetime. The Weibull hazard function for pipe lifetime is then used to estimate the expected failure rate (per pipe length/per year) as a function of pipe age. To validate the model, predicted failure rates are compared to aggregated failure data from 17 UK water utilities obtained from the United Kingdom Water Industry Research (UKWIR) National Mains Failure Database. In the absence of actual operating pressure data in the UKWIR database, typical

  13. The internal model: A study of the relative contribution of proprioception and visual information to failure detection in dynamic systems. [sensitivity of operators versus monitors to failures

    Science.gov (United States)

    Kessel, C.; Wickens, C. D.

    1978-01-01

    The development of the internal model as it pertains to the detection of step changes in the order of control dynamics is investigated for two modes of participation: whether the subjects are actively controlling those dynamics or are monitoring an autopilot controlling them. A transfer of training design was used to evaluate the relative contribution of proprioception and visual information to the overall accuracy of the internal model. Sixteen subjects either tracked or monitored the system dynamics as a 2-dimensional pursuit display under single task conditions and concurrently with a sub-critical tracking task at two difficulty levels. Detection performance was faster and more accurate in the manual as opposed to the autopilot mode. The concurrent tracking task produced a decrement in detection performance for all conditions though this was more marked for the manual mode. The development of an internal model in the manual mode transferred positively to the automatic mode producing enhanced detection performance. There was no transfer from the internal model developed in the automatic mode to the manual mode.

  14. EARLY DIAGNOSIS OF IMMUNE DISTURBANCES AND ITS CORRECTION IN THE TREATMENT OF MULTIORGAN FAILURE AND SEPTIC COMPLICATIONS AFTER OPERATIONS WITH ARTIFICIAL AND ASSIST CIRCULATION

    Directory of Open Access Journals (Sweden)

    V. S. Suskova

    2009-01-01

    Full Text Available The study has shown that early diagnosis of the type and degree of immune disturbances in preparation for the operation and the first signs of multiorgan failure and septic complications in the postoperative period in cardiac surgery patients were the rationale for the earlier substitution immunocorrection by immunomodulators of cytokine nature and intravenous immunoglobulin. It allowed increasing the efficiency of the treatment of postoperative complications and lower mortality after operations with artificial and assist circulation. 

  15. Development and using computer codes for improvement of defect assembly detection on Russian WWER NPPs

    International Nuclear Information System (INIS)

    Likhanskii, V.; Evdokimov, I.; Zborovskii, V.; Kanukova, V.; Sorokin, A.; Taran, M.; Ugrumov, A.; Riabinin, Y.

    2009-01-01

    Diagnostic methods of fuel failure detection for improving the radiation safety and shortening of fuel reload time at Russian WWERs are currently in development . The works include creation new computer means for increase of effectiveness of fuel monitoring and reliability of leakage tests. Reliability of failure detection can be noticeably improved when we apply an integrated approach including the following methods. The first is fuel failure analysis under operating conditions. Analysis is performed with the pilot version of the expert system, which has been developed on the basis of the mechanistic code RTOP-CA. The second stage of failure monitoring is 'sipping' tests in the mast of the refueling machine. The leakage tests are the final stage of failure monitoring. A new technique with pressure cycling in the specialized casks was introduced to meet the requirements of higher reliability in detection/confirmation of the leakages. Measurements of the activity release kinetics during the pressure cycling and handling of the acquired data with the RTOP-LT code enable to evaluate a defect size in leaking fuel assembly. The mechanistic codes RTOP-CA and RTOP-LT were verified on a base of specialized experimental data and currently the code were certified by Russian authorities Rostechnadzor. Now the pressure cycling method in the specialized casks has official status and is utilized at the all Russian WWER units. Some results of application of the integrated approach to fuel failure monitoring at several Russian NPPs with WWER units are reported in the present paper. Predictions of the current version of the expert system are compared with the results of the leakage tests and with the estimations of the defect size by the pressure cycling technique. Using the RTOP-CA code the level of activity is assessed for the following fuel campaign if the leaking fuel assembly was decided to be reloaded into the core. A project of the automated computer system on the basis of

  16. Design Margin Elimination Through Robust Timing Error Detection at Ultra-Low Voltage

    OpenAIRE

    Reyserhove, Hans; Dehaene, Wim

    2017-01-01

    This paper discusses a timing error masking-aware ARM Cortex M0 microcontroller system. Through in-path timing error detection, operation at the point-of-first-failure is possi- ble without corrupting the pipeline state, effectively eliminat- ing traditional timing margins. Error events are flagged and gathered to allow dynamic voltage scaling. The error-aware microcontroller was implemented in a 40nm CMOS process and realizes ultra-low voltage operation down to 0.29V at 5MHz consuming 12.90p...

  17. METAL:LIC target failure diagnostics by means of liquid metal loop vibrations monitoring

    International Nuclear Information System (INIS)

    Dementjevs, S.; Barbagallo, F.; Wohlmuther, M.; Thomsen, K.; Zik, A.; Nikoluskins, R.

    2014-01-01

    A target mock-up, developed as an European Spallation Source comparative solution, (METAL:LIC) has been tested in a dedicated lead bismuth eutectic (LBE) loop in the Institute of Physics at the University of Latvia. In particular, the feasibility of diagnostic vibration monitoring has been investigated. The loop parameters were: operation temperature 300°C; tubing ∅100 mm, overall length 8 m; electromagnetic pump based on permanent magnets, flow rate 180 kg/s. With sufficient static pressure of a few bars, cavitation was avoided. The vibrations in the loop were measured and analyzed. Several vibrational characteristics of the set-up were derived including resonance frequencies and the dependence of excited vibrations on flow conditions and the pump rotation speed. A high sensitivity to obstructions in the loop has been confirmed, and several indicators for target failure diagnostics were tested and compared. A problem in the electromagnetic pump's gear box has been detected in a very early state long before it manifested itself in the operation of the loop. The vibration monitoring has been demonstrated as a sensitive and reliable probe for the target failure diagnostics. (author)

  18. Analysis of human factor in operation of nuclear power plants

    International Nuclear Information System (INIS)

    Husseiny, A.A.; Sabri, Z.A.

    1980-01-01

    A taxonomy of operator errors is developed here to provide a scheme for compiling data from field experience according to their significance to the operation and their influence on the plant performance. The reversibility of operator actions is taken as the basis of detection of the relevances of errors to the overall operation. In addition, distinction is made between system errors, such as inadequate instrumentation or logistics, and 'operator errors', which indicate that the operator is involved in inducing an operational error rather than being uniquely responsible for an incident. The developed taxonomy can be used for evaluation of the performance of operators during scheduled training programs. Identification of each class of errors would assist in upgrading performance of operators in a given plant and in filing occurrence reports that help in revising safety provisions or operation procedures. The scheme is suitable for sorting and storing failure information in a data library for ease of retrieval by reliability analysis codes. (orig.) [de

  19. Detection algorithm of infrared small target based on improved SUSAN operator

    Science.gov (United States)

    Liu, Xingmiao; Wang, Shicheng; Zhao, Jing

    2010-10-01

    The methods of detecting small moving targets in infrared image sequences that contain moving nuisance objects and background noise is analyzed in this paper. A novel infrared small target detection algorithm based on improved SUSAN operator is put forward. The algorithm selects double templates for the infrared small target detection: one size is greater than the small target point size and another size is equal to the small target point size. First, the algorithm uses the big template to calculate the USAN of each pixel in the image and detect the small target, the edge of the image and isolated noise pixels; Then the algorithm uses the another template to calculate the USAN of pixels detected in the first step and improves the principles of SUSAN algorithm based on the characteristics of the small target so that the algorithm can only detect small targets and don't sensitive to the edge pixels of the image and isolated noise pixels. So the interference of the edge of the image and isolate noise points are removed and the candidate target points can be identified; At last, the target is detected by utilizing the continuity and consistency of target movement. The experimental results indicate that the improved SUSAN detection algorithm can quickly and effectively detect the infrared small targets.

  20. A model for the coupling of failure rates in a redundant system

    International Nuclear Information System (INIS)

    Kleppmann, W.G.; Wutschig, R.

    1986-01-01

    A model is developed which takes into acount the coupling between failure rates or identical components in different redundancies of a safety system, i.e., the fact that the failure rates of identical components subjected to the same operating conditions will scatter less than the failure rates of any two components of the same type. It is shown that with increasing coupling the expectation value and the variance of the distribution of the failure probability of the redundant system increases. A consistent way to incorporate operating experience in a Bayesian framework is developed and the reults are presented. (orig.)

  1. Simulation of worst-case operating conditions for integrated circuits operating in a total dose environment

    International Nuclear Information System (INIS)

    Bhuva, B.L.

    1987-01-01

    Degradations in the circuit performance created by the radiation exposure of integrated circuits are so unique and abnormal that thorough simulation and testing of VLSI circuits is almost impossible, and new ways to estimate the operating performance in a radiation environment must be developed. The principal goal of this work was the development of simulation techniques for radiation effects on semiconductor devices. The mixed-mode simulation approach proved to be the most promising. The switch-level approach is used to identify the failure mechanisms and critical subcircuits responsible for operational failure along with worst-case operating conditions during and after irradiation. For precise simulations of critical subcircuits, SPICE is used. The identification of failure mechanisms enables the circuit designer to improve the circuit's performance and failure-exposure level. Identification of worst-case operating conditions during and after irradiation reduces the complexity of testing VLSI circuits for radiation environments. The results of test circuits for failure simulations using a conventional simulator and the new simulator showed significant time savings using the new simulator. The savings in simulation time proved to be circuit topology-dependent. However, for large circuits, the simulation time proved to be orders of magnitude smaller than simulation time for conventional simulators

  2. Investigation of Effectiveness of Some Vibration-Based Techniques in Early Detection of Real-Time Fatigue Failure in Gears

    Directory of Open Access Journals (Sweden)

    Hasan Ozturk

    2010-01-01

    Full Text Available Bending fatigue crack is a dangerous and insidious mode of failure in gears. As it produces no debris in its early stages, it gives little warning during its progression, and usually results in either immediate loss of serviceability or greatly reduced power transmitting capacity. This paper presents the applications of vibration-based techniques (i.e. conventional time and frequency domain analysis, cepstrum, and continuous wavelet transform to real gear vibrations in the early detection, diagnosis and advancement monitoring of a real tooth fatigue crack and compares their detection and diagnostic capabilities on the basis of experimental results. Gear fatigue damage is achieved under heavy-loading conditions and the gearbox is allowed to run until the gears suffer badly from complete tooth breakage. It has been found that the initiation and progression of fatigue crack cannot be easily detected by conventional time and frequency domain approaches until the fault is significantly developed. On the contrary, the wavelet transform is quite sensitive to any change in gear vibration and reveals fault features earlier than other methods considered.

  3. Discussion of ISV Scenario Scope with Operating Process Element

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Goo; Oh, Eungse [Korea Hydro and Nuclear Power Co. ltd. Central Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    NUREG-0711 identifies the sampling dimension of operational conditions which includes normal operation,I and C and HSI failures, transient, and accidents. Because of practical limitation of sampling, ISV scenarios do not include every expected operational condition. To develop a scenario for the ISV, it requires much time and efforts. It takes about 1 month with 3 operating crew team for 7 scenarios for the ISV. Therefore, operational conditions are screened out for integration to scenario. TSV can be used for the evaluation of monitoring, detection, and response implementation about the inventory of information and control. However, validity of operational walkthrough for other operating process element needs to be discussed. For the situation awareness, the general acceptance check list can be derived from the result of representative scenario set of ISV. The check list may contain the number of information, type of information, level of procedure and training program. For the response planning, procedure can be used for evaluation.

  4. Strategies for optical transport network recovery under epidemic network failures

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Fagertun, Anna Manolova; Kosteas, Vasileios

    2015-01-01

    The current trend in deploying automatic control plane solutions for increased flexibility in the optical transport layer leads to numerous advantages for both the operators and the customers, but also pose challenges related to the stability of the network and its ability to operate in a robust...... manner under different failure scenarios. This work evaluates two rerouting strategies and proposes four policies for failure handling in a connection-oriented optical transport network, under generalized multiprotocol label switching control plane. The performance of the strategies and the policies......, and that there exist a clear trade-off between policy performance and network resource consumption, which must be addressed by network operators for improved robustness of their transport infrastructures. Applying proactive methods for avoiding areas where epidemic failures spread results in 50% less connections...

  5. Evaluation of the adequacy of maintenance tasks using the failure consequences of railroad vehicles

    International Nuclear Information System (INIS)

    Kim, Jaehoon; Jeong, Hyun- Yong

    2013-01-01

    The purpose of this study is to improve the efficiency, reliability and safety related to railroad maintenance tasks through an evaluation of the consequences of failures. The brake system was selected based on the failure data obtained from railroad vehicles in operation as one of the safety systems in railroad vehicles. The failure causes, failure effects, and the criticality of the failure mode were drawn for 62 failure modes of the braking system through the use of an FMECA for the 30 sub-devices having primary functions. The various maintenance tasks for the braking system were categorized into the 62 failure modes and failure consequences using the FMECA and the logic of maintenance decisions. Braking systems manufactured by the same manufacturer and operated by two different operators were studied in an effort to analyze preventive maintenance and to evaluate the adequacy of preventive maintenance tasks for the 62 failure modes. Based on results of the evaluation of these preventive maintenance tasks, new maintenance tasks were proposed, and concrete cost-cutting effects were determined from the calculation of the maintenance time and expected costs, using a preventive maintenance template developed specifically for railroad vehicles

  6. MATHEMATICAL MODEL OF WEAR CHARACTER FAILURE IN AIRCRAFT OPERATION

    OpenAIRE

    Радько, Олег Віталійович; Молдован, Володимир Дмитрович

    2016-01-01

    In this paper the mathematical model of failures associated with wear during aircraft exploitationis developed. Тhe calculations of the distribution function, distribution density and failurerate gamma distribution at low coefficients of variation and the relatively low value of averagewear rate for the current time, which varies quite widely. The results coincide well with thephysical concepts and can be used to build different models of aircraft. Gamma distribution is apretty good model for...

  7. Failure Mechanisms and Color Stability in Light-Emitting Diodes during Operation in High- Temperature Environments in Presence of Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lall, Pradeep; Zhang, Hao; Davis, J Lynn

    2015-05-26

    The energy efficiency of light-emitting diode (LED) technology compared to incandescent light bulbs has triggered an increased focus on solid state luminaries for a variety of lighting applications. Solid-state lighting (SSL) utilizes LEDs, for illumination through the process of electroluminescence instead of heating a wire filament as seen with traditional lighting. The fundamental differences in the construction of LED and the incandescent lamp results in different failure modes including lumen degradation, chromaticity shift and drift in the correlated color temperature. The use of LED-based products for safety-critical and harsh environment applications necessitates the characterization of the failure mechanisms and modes. In this paper, failure mechanisms and color stability has been studied for commercially available vertical structured thin film LED (VLED) under harsh environment conditions with and without the presence of contaminants. The VLED used for the study was mounted on a ceramic starboard in order to connect it to the current source. Contamination sources studied include operation in the vicinity of vulcanized rubber and adhesive epoxies in the presence of temperature and humidity. Performance of the VLEDs has been quantified using the measured luminous flux and color shift of the VLEDs subjected to both thermal and humidity stresses under a forward current bias of 350 mA. Results indicate that contamination can result in pre-mature luminous flux degradation and color shift in LEDs.

  8. Detection device for off-gas system accidents

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Tsuruoka, Ryozo; Yamanari, Shozo.

    1984-01-01

    Purpose: To rapidly isolate the off-gas system by detecting the off-gas system failure accident in a short time. Constitution: Radiation monitors are disposed to ducts connecting an exhaust gas area and an air conditioning system as a portion of a turbine building. The ducts are disposed independently such that they ventilate only the atmosphere in the exhaust gas area and do not mix the atmosphere in the turbine building. Since radioactivity issued upon off-gas accidents to the exhaust gas area is sucked to the duct, it can be detected by radiation detection monitors in a short time after the accident. Further, since the operator judges it as the off-gas system accident, the off-gas system can be isolated in a short time after the accident. (Moriyama, K.)

  9. Detection of mechanical failures in induction motors by current spectrum analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sokansky, K; Novak, P; Bilos, J; Labaj, J [Technical University Ostrava, Moraviasilesian Power Stations s.h.c. (Czech Republic)

    1998-12-31

    From the diagnostic point of view, an electric machine can be understood as an electromechanical system. It means that any manifestations of mechanical failures do not have to show themselves only in mechanical quantities, i.e. vibration in our case. Mechanical failures can also manifest themselves in electrical quantities, namely in electric current in our case. This statement is valid inversely too, which means that faults occurring in electric circuits can be measured through mechanical quantities. This presentation deals with measuring the current spectra of induction motors with short circuited armatures that are drives used in the industries most. (orig.) 3 refs.

  10. Detection of mechanical failures in induction motors by current spectrum analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sokansky, K.; Novak, P.; Bilos, J.; Labaj, J. [Technical University Ostrava, Moraviasilesian Power Stations s.h.c. (Czech Republic)

    1997-12-31

    From the diagnostic point of view, an electric machine can be understood as an electromechanical system. It means that any manifestations of mechanical failures do not have to show themselves only in mechanical quantities, i.e. vibration in our case. Mechanical failures can also manifest themselves in electrical quantities, namely in electric current in our case. This statement is valid inversely too, which means that faults occurring in electric circuits can be measured through mechanical quantities. This presentation deals with measuring the current spectra of induction motors with short circuited armatures that are drives used in the industries most. (orig.) 3 refs.

  11. Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems

    Science.gov (United States)

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290

  12. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    Directory of Open Access Journals (Sweden)

    Tung-Ching Su

    2014-05-01

    Full Text Available As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED, to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO and closing bottom-hat operation (CBHO, were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  13. A quantitative method for Failure Mode and Effects Analysis

    NARCIS (Netherlands)

    Braaksma, Anne Johannes Jan; Meesters, A.J.; Klingenberg, W.; Hicks, C.

    2012-01-01

    Failure Mode and Effects Analysis (FMEA) is commonly used for designing maintenance routines by analysing potential failures, predicting their effect and facilitating preventive action. It is used to make decisions on operational and capital expenditure. The literature has reported that despite its

  14. Satellite failures revisited

    Science.gov (United States)

    Balcerak, Ernie

    2012-12-01

    In January 1994, the two geostationary satellites known as Anik-E1 and Anik-E2, operated by Telesat Canada, failed one after the other within 9 hours, leaving many northern Canadian communities without television and data services. The outage, which shut down much of the country's broadcast television for hours and cost Telesat Canada more than $15 million, generated significant media attention. Lam et al. used publicly available records to revisit the event; they looked at failure details, media coverage, recovery effort, and cost. They also used satellite and ground data to determine the precise causes of those satellite failures. The researchers traced the entire space weather event from conditions on the Sun through the interplanetary medium to the particle environment in geostationary orbit.

  15. Failure analysis – basic step of applying Reliability Centered Maintenance in general aviation

    Directory of Open Access Journals (Sweden)

    Martin BUGAJ

    2012-01-01

    Full Text Available Performing a reliability analysis on a product or system can actually include a number of different analyses to determine how reliable the product or system is. A reliability centered maintenance program consists of a set of scheduled tasks generated on the basis of specific reliability characteristics of the equipment they are designed to protect. Complex equipment is composed of a vast number of parts and assemblies. All these items can be expected to fail at one time or another, but some of the failures have more serious consequences than others. Certain kinds of failures have a direct effect on operating safety, and others affect the operational capability of the equipment. The consequences of a particular failure depend on the design of the item and the equipment in which it is installed. Although the environment in which the equipment is operated is sometimes an additional factor, the impact of failures on the equipment, and hence their consequences for the operating organization, are established primarily by the equipment designer. Failure consequences are therefore a primary inherent reliability characteristic.

  16. Failure diagnosis and fault tree analysis

    International Nuclear Information System (INIS)

    Weber, G.

    1982-07-01

    In this report a methodology of failure diagnosis for complex systems is presented. Systems which can be represented by fault trees are considered. This methodology is based on switching algebra, failure diagnosis of digital circuits and fault tree analysis. Relations between these disciplines are shown. These relations are due to Boolean algebra and Boolean functions used throughout. It will be shown on this basis that techniques of failure diagnosis and fault tree analysis are useful to solve the following problems: 1. describe an efficient search of all failed components if the system is failed. 2. Describe an efficient search of all states which are close to a system failure if the system is still operating. The first technique will improve the availability, the second the reliability and safety. For these problems, the relation to methods of failure diagnosis for combinational circuits is required. Moreover, the techniques are demonstrated for a number of systems which can be represented by fault trees. (orig./RW) [de

  17. Supporting dynamic change detection: using the right tool for the task.

    Science.gov (United States)

    Vallières, Benoît R; Hodgetts, Helen M; Vachon, François; Tremblay, Sébastien

    2016-01-01

    Detecting task-relevant changes in a visual scene is necessary for successfully monitoring and managing dynamic command and control situations. Change blindness-the failure to notice visual changes-is an important source of human error. Change History EXplicit (CHEX) is a tool developed to aid change detection and maintain situation awareness; and in the current study we test the generality of its ability to facilitate the detection of changes when this subtask is embedded within a broader dynamic decision-making task. A multitasking air-warfare simulation required participants to perform radar-based subtasks, for which change detection was a necessary aspect of the higher-order goal of protecting one's own ship. In this task, however, CHEX rendered the operator even more vulnerable to attentional failures in change detection and increased perceived workload. Such support was only effective when participants performed a change detection task without concurrent subtasks. Results are interpreted in terms of the NSEEV model of attention behavior (Steelman, McCarley, & Wickens, Hum. Factors 53:142-153, 2011; J. Exp. Psychol. Appl. 19:403-419, 2013), and suggest that decision aids for use in multitasking contexts must be designed to fit within the available workload capacity of the user so that they may truly augment cognition.

  18. 33 CFR 385.28 - Operating Manuals.

    Science.gov (United States)

    2010-07-01

    ... Processes § 385.28 Operating Manuals. (a) General provisions. (1) The Corps of Engineers and the non-Federal... emergencies that can be expected to occur at a project are: drowning and other accidents, failure of the operation facilities, chemical spills, treatment plant failures and other temporary pollution problems...

  19. An Adaptive Failure Detector Based on Quality of Service in Peer-to-Peer Networks

    Directory of Open Access Journals (Sweden)

    Jian Dong

    2014-09-01

    Full Text Available The failure detector is one of the fundamental components that maintain high availability of Peer-to-Peer (P2P networks. Under different network conditions, the adaptive failure detector based on quality of service (QoS can achieve the detection time and accuracy required by upper applications with lower detection overhead. In P2P systems, complexity of network and high churn lead to high message loss rate. To reduce the impact on detection accuracy, baseline detection strategy based on retransmission mechanism has been employed widely in many P2P applications; however, Chen’s classic adaptive model cannot describe this kind of detection strategy. In order to provide an efficient service of failure detection in P2P systems, this paper establishes a novel QoS evaluation model for the baseline detection strategy. The relationship between the detection period and the QoS is discussed and on this basis, an adaptive failure detector (B-AFD is proposed, which can meet the quantitative QoS metrics under changing network environment. Meanwhile, it is observed from the experimental analysis that B-AFD achieves better detection accuracy and time with lower detection overhead compared to the traditional baseline strategy and the adaptive detectors based on Chen’s model. Moreover, B-AFD has better adaptability to P2P network.

  20. An Adaptive Failure Detector Based on Quality of Service in Peer-to-Peer Networks

    Science.gov (United States)

    Dong, Jian; Ren, Xiao; Zuo, Decheng; Liu, Hongwei

    2014-01-01

    The failure detector is one of the fundamental components that maintain high availability of Peer-to-Peer (P2P) networks. Under different network conditions, the adaptive failure detector based on quality of service (QoS) can achieve the detection time and accuracy required by upper applications with lower detection overhead. In P2P systems, complexity of network and high churn lead to high message loss rate. To reduce the impact on detection accuracy, baseline detection strategy based on retransmission mechanism has been employed widely in many P2P applications; however, Chen's classic adaptive model cannot describe this kind of detection strategy. In order to provide an efficient service of failure detection in P2P systems, this paper establishes a novel QoS evaluation model for the baseline detection strategy. The relationship between the detection period and the QoS is discussed and on this basis, an adaptive failure detector (B-AFD) is proposed, which can meet the quantitative QoS metrics under changing network environment. Meanwhile, it is observed from the experimental analysis that B-AFD achieves better detection accuracy and time with lower detection overhead compared to the traditional baseline strategy and the adaptive detectors based on Chen's model. Moreover, B-AFD has better adaptability to P2P network. PMID:25198005

  1. The frequency and determinants of liver stiffness measurement failure: a retrospective study of "real-life" 38,464 examinations.

    Directory of Open Access Journals (Sweden)

    Dong Ji

    Full Text Available To investigate the frequency and determinants of liver stiffness measurement (LSM failure by means of FibroScan in "real-life" Chinese patients.A total of 38,464 "real-life" Chinese patients in 302 military hospital of China through the whole year of 2013, including asymptomatic carrier, chronic hepatitis B, chronic hepatitis C, liver cirrhosis (LC, alcoholic liver disease, autoimmune liver disease, hepatocellular carcinoma (HCC and other, were enrolled, their clinical and biological parameters were retrospectively investigated. Liver fibrosis was evaluated by FibroScan detection. S probe (for children with height less than 1.20 m and M probe (for adults were used. LSM failure defined as zero valid shots (unsuccessful LSM, or the ratio of the interquartile range to the median of 10 measurements (IQR/M greater than 0.30 plus median LSM greater or equal to 7.1 kPa (unreliable LSM.LSM failure occurred in 3.34% of all examinations (1286 patients out of 38,464, among them, there were 958 cases (2.49% with unsuccessful LSM, and 328 patients (0.85% with unreliable LSM. Statistical analyses showed that LSM failure was independently associated with body mass index (BMI greater than 30 kg/m(2, female sex, age greater than 50 years, intercostal spaces (IS less than 9 mm, decompensated liver cirrhosis and HCC patients. There were no significant differences among other diseases. By changing another skilled operator, success was achieved on 301 cases out of 1286, which reduced the failure rate to 2.56%, the decrease was significant (P<0.0001.The principal reasons of LSM failure are ascites, obesity and narrow of IS. The failure rates of HCC, decompensated LC, elder or female patients are higher. These results emphasize the need for adequate operator training, technological improvements and optimal criteria for specific patient subpopulations.

  2. Risk factors for postoperative liver failure after hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Maeda, Yoshitaka; Nishida, Minekatsu; Takao, Takashi; Mori, Naohide; Tamesa, Takao; Tangoku, Akira; Oka, Masaaki

    2004-01-01

    Selection of patients for hepatectomy for hepatocellular carcinoma conventionally has been based upon Child-Pugh grading. However, postoperative liver failure after hepatectomy is a major cause of hospital mortality. A new predictor of postoperative liver failure is required. The objective of this study was to identify risk factors for postoperative liver failure after hepatectomy. Perioperative risk factors for liver failure after hepatectomy were analyzed in 112 patients with hepatocellular carcinoma Eight of these patients died of liver failure. Stepwise multivariate logistic regression was performed to investigate significant independent factors among 17 variables, including the serum alkaline phosphatase ratio (ALPR) on the first day after hepatectomy. ALPR was calculated as the postoperative ALP level divided by the ALP level before surgery. Significant risk factors of postoperative liver failure were ALPR on postoperative day 1 (ALPR1), sex, operative blood loss, and operative procedure. As an indicator of liver failure, the diagnostic accuracy of the ALPR1 was 93.7% when the ALPR was less than 0.4 on the first postoperative day. The ALPR and the serum total bilirubin concentration after hepatectomy were uncorrelated. ALPR1 is a useful predictor of liver failure after hepatectomy.

  3. A review of recent advances in data analytics for post-operative patient deterioration detection.

    Science.gov (United States)

    Petit, Clemence; Bezemer, Rick; Atallah, Louis

    2018-06-01

    Most deaths occurring due to a surgical intervention happen postoperatively rather than during surgery. The current standard of care in many hospitals cannot fully cope with detecting and addressing post-surgical deterioration in time. For millions of patients, this deterioration is left unnoticed, leading to increased mortality and morbidity. Postoperative deterioration detection currently relies on general scores that are not fully able to cater for the complex post-operative physiology of surgical patients. In the last decade however, advanced risk and warning scoring techniques have started to show encouraging results in terms of using the large amount of data available peri-operatively to improve postoperative deterioration detection. Relevant literature has been carefully surveyed to provide a summary of the most promising approaches as well as how they have been deployed in the perioperative domain. This work also aims to highlight the opportunities that lie in personalizing the models developed for patient deterioration for these particular post-surgical patients and make the output more actionable. The integration of pre- and intra-operative data, e.g. comorbidities, vitals, lab data, and information about the procedure performed, in post-operative early warning algorithms would lead to more contextualized, personalized, and adaptive patient modelling. This, combined with careful integration in the clinical workflow, would result in improved clinical decision support and better post-surgical care outcomes.

  4. Causes and effects of vital instrumentation and control power supply bus failures

    International Nuclear Information System (INIS)

    Muhlheim, M.D.; Murphy, G.A.

    1987-01-01

    This article presents the results of a study in which the objective was to evaluate nuclear power-plant operating experience to identify the causes and the effects of vital instrumentation and control (I and C) power supply bus failures. Vital I and C power is normally provided to essential instrumentation and controls through either vital d-c or a-c power supply systems. The vital d-c power supply system generally provides control power for starting the diesel generators, for operating electrical circuit breakers, and for controlling various logic circuits. The vital d-c power system also supplies vital a-c power through an inverter. The vital a-c power supply system generally feeds the reactor protection system channels, the engineered safety features actuation system channels, and critical instrumentation in the control room. The leading cause of vital bus failures is inverter failures; other causes are human errors, battery charger failures, and miscellaneous failures. The effects of these failures are that the margin of safety can be degraded by (1) denying key information to the operators, (2) inducing plant transients, (3) causing safety injection actuations, and (4) causing the loss of shutdown cooling flow

  5. Program computes single-point failures in critical system designs

    Science.gov (United States)

    Brown, W. R.

    1967-01-01

    Computer program analyzes the designs of critical systems that will either prove the design is free of single-point failures or detect each member of the population of single-point failures inherent in a system design. This program should find application in the checkout of redundant circuits and digital systems.

  6. Statistical analysis of nuclear power plant pump failure rate variability: some preliminary results

    International Nuclear Information System (INIS)

    Martz, H.F.; Whiteman, D.E.

    1984-02-01

    In-Plant Reliability Data System (IPRDS) pump failure data on over 60 selected pumps in four nuclear power plants are statistically analyzed using the Failure Rate Analysis Code (FRAC). A major purpose of the analysis is to determine which environmental, system, and operating factors adequately explain the variability in the failure data. Catastrophic, degraded, and incipient failure severity categories are considered for both demand-related and time-dependent failures. For catastrophic demand-related pump failures, the variability is explained by the following factors listed in their order of importance: system application, pump driver, operating mode, reactor type, pump type, and unidentified plant-specific influences. Quantitative failure rate adjustments are provided for the effects of these factors. In the case of catastrophic time-dependent pump failures, the failure rate variability is explained by three factors: reactor type, pump driver, and unidentified plant-specific influences. Finally, point and confidence interval failure rate estimates are provided for each selected pump by considering the influential factors. Both types of estimates represent an improvement over the estimates computed exclusively from the data on each pump

  7. Non-operative diagnosis - effect on repeat-operation rates in the UK breast screening programme

    International Nuclear Information System (INIS)

    Wallis, M.G.; Cheung, S.; Kearins, O.; Lawrence, G.M.

    2009-01-01

    Non-operative diagnosis rates in the UK breast screening programme have improved dramatically from 48.8% in 1994/95 (only nine units achieved the then minimum standard of 70%) to 94% in 2005/06 (only seven units failed to achieve the target of 90%). Preoperative and operative history of all 120,550 women diagnosed with screen-detected breast cancer in the UK between April 1994 and March 2006 was derived from different national databases. In 2005/06, 2,790 (17.8%) of the 15,688 women having surgery needed two or more operations. In 2001/02 (non-operative diagnosis rate 87%), the re-operation rate was 23.8% (2,377 of 9,969). Extrapolation backwards to 1994/95 (non-operative diagnosis rate 48.8%) suggests a re-operation rate of 62%. Analysis over the 4 years from April 2002 (n=34,198) demonstrates that 4,089 (12%) women with a correct non-operative diagnosis of invasive disease required additional surgery compared to 1,166 (48%) of women who were under-staged (diagnosed as non-invasive based on core biopsy, but actually suffering from invasive disease). Failure to achieve a non-operative diagnosis of invasive disease (n=1,542) or non-invasive disease (n=2,247) resulted in re-operation rates of 65 and 43% respectively. Given the impact of not having a diagnosis pre-operatively, or of under-staging invasive carcinoma, it seems timely to introduce more sophisticated standards. (orig.)

  8. Salmonella Gastroenteritis Due to Rhabdomyolysis and Acute Renal Failure with Acute Pancreatitis Case Report

    Directory of Open Access Journals (Sweden)

    Şenay Canikli Adıgüzel

    2017-12-01

    Full Text Available In this study, we are reporting a case of acute pancreatitis, acute renal failure (ARF and rhabdomyolysis which are rare serious complications of the Salmonella gastroenteritis. A patient presented as an emergency with fever, abdominal pain, and ARF complexion was operated urgently by ileus pre-diagnosis. There was not surgical pathology detected during the operation. However, Salmonella paratyphi A in feces of patient with high levels of amylase, lipase, and creatinine were reported during intensive care unit (ICU admission. The patient was diagnosed with acute pancreatitis due to Salmonella infection. During ICU stay, the levels of amylase and lipase were reduced and the kidney functions improved without hemodialysis. On the 7th day, patient was transferred to the general surgical service.

  9. Failure trend analysis for safety related components of Korean standard NPPs

    International Nuclear Information System (INIS)

    Choi, Sun Yeong; Han, Sang Hoon

    2005-01-01

    The component reliability data of Korean NPP that reflects the plant specific characteristics is required necessarily for PSA of Korean nuclear power plants. We have performed a project to develop the component reliability database (KIND, Korea Integrated Nuclear Reliability Database) and S/W for database management and component reliability analysis. Based on the system, we have collected the component operation data and failure/repair data during from plant operation date to 2002 for YGN 3, 4 and UCN 3, 4 plants. Recently, we provided the component failure rate data for UCN 3, 4 standard PSA model from the KIND. We evaluated the components that have high-ranking failure rates with the component reliability data from plant operation date to 1998 and 2000 for YGN 3,4 and UCN 3, 4 respectively. We also identified their failure mode that occurred frequently. In this study, we analyze the component failure trend and perform site comparison based on the generic data by using the component reliability data which is extended to 2002 for UCN 3, 4 and YGN 3, 4 respectively. We focus on the major safety related rotating components such as pump, EDG etc

  10. Internet optical infrastructure issues on monitoring and failure restoration

    CERN Document Server

    Tapolcai, János; Babarczi, Péter; Rónyai, Lajos

    2015-01-01

    This book covers the issues of monitoring, failure localization, and restoration in the Internet optical backbone, and focuses on the progress of state-of-the-art in both industry standard and academic research. The authors summarize, categorize, and analyze the developed technology in the context of Internet fault management and failure recovery under the Generalized Multi-Protocol Label Switching (GMPLS), via both aspects of network operations and theories. Examines monitoring, failure localization, and failure restoration in the Internet backbone Includes problem formulations based on combinatorial group testing and topology coding Covers state-of-the-art development for the Internet backbone fault management and failure recovery

  11. Functional-logic simulation of IP-blocks dose functional failures

    Directory of Open Access Journals (Sweden)

    Vyacheslav M. Barbashov

    2017-11-01

    Full Text Available The technique of functional-logical simulation of System-on-Chip (SoC total dose radiation failures is presented based on fuzzy logic sets theory. An analysis of the capabilities of this approach for IP-blocks radiation behavior is carried out along with the analysis of operating modes under irradiation influence on IP-blocks radiation behavior. The following elements of this technique application for simulation of dose radiation failures of various types of IP-units are studied: logical elements, memory units and cells, processors. Examples of criterial membership functions and operability functions construction are given for these IP-units and for various critical parameters characterizing their failures. It is shown that when modeling total dose failures it is necessary to take into account the influence of the functional mode on the model parameters. The technique proposed allows improving the reliability of the SoC radiation hardness estimation, also for the purpose of solving the problems of information security of electronic devices.

  12. Failure rate of piping in hydrogen sulphide systems

    International Nuclear Information System (INIS)

    Hare, M.G.

    1993-08-01

    The objective of this study is to provide information about piping failures in hydrogen sulphide service that could be used to establish failures rates for piping in 'sour service'. Information obtained from the open literature, various petrochemical industries and the Bruce Heavy Water Plant (BHWP) was used to quantify the failure analysis data. On the basis of this background information, conclusions from the study and recommendations for measures that could reduce the frequency of failures for piping systems at heavy water plants are presented. In general, BHWP staff should continue carrying out their present integrity and leak detection programmes. The failure rate used in the safety studies for the BHWP appears to be based on the rupture statistics for pipelines carrying sweet natural gas. The failure rate should be based on the rupture rate for sour gas lines, adjusted for the unique conditions at Bruce

  13. Hydriding failure in water reactor fuel elements

    International Nuclear Information System (INIS)

    Sah, D.N.; Ramadasan, E.; Unnikrishnan, K.

    1980-01-01

    Hydriding of the zircaloy cladding has been one of the important causes of failure in water reactor fuel elements. This report reviews the causes, the mechanisms and the methods for prevention of hydriding failure in zircaloy clad water reactor fuel elements. The different types of hydriding of zircaloy cladding have been classified. Various factors influencing zircaloy hydriding from internal and external sources in an operating fuel element have been brought out. The findings of post-irradiation examination of fuel elements from Indian reactors, with respect to clad hydriding and features of hydriding failure are included. (author)

  14. Failure Analysis Of Industrial Boiler Pipe

    International Nuclear Information System (INIS)

    Natsir, Muhammad; Soedardjo, B.; Arhatari, Dewi; Andryansyah; Haryanto, Mudi; Triyadi, Ari

    2000-01-01

    Failure analysis of industrial boiler pipe has been done. The tested pipe material is carbon steel SA 178 Grade A refer to specification data which taken from Fertilizer Company. Steps in analysis were ; collection of background operation and material specification, visual inspection, dye penetrant test, radiography test, chemical composition test, hardness test, metallography test. From the test and analysis result, it is shown that the pipe failure caused by erosion and welding was shown porosity and incomplete penetration. The main cause of failure pipe is erosion due to cavitation, which decreases the pipe thickness. Break in pipe thickness can be done due to decreasing in pipe thickness. To anticipate this problem, the ppe will be replaced with new pipe

  15. Development of an integrated condition monitoring and diagnostic system for motor-operated valves used in nuclear power plant

    International Nuclear Information System (INIS)

    Carneiro, Alvaro Luiz Guimaraes

    2003-01-01

    The reliability question of the components, specifically of motor operated valves, became one of the most important issues to be investigated in nuclear power plants, considering security and life plant extension. Therefore, the necessity of improvements in monitoring and diagnosis methods started to be of extreme relevance in the maintenance predictive field, establishing as main goal the reliability and readiness of the system components. Specially in nuclear power plants, the predictive maintenance contributes in the security factor in order to diagnosis in advance the occurrence of a possible failure, preventing severe situations. It also presents a contribution on the economic side by establishing a better maintenance programming, and reducing unexpected shutdown. The development of non intrusive monitoring and diagnostic method makes it possible to identify malfunctions in plant components during normal plant operation. This dissertation presents the development of an integrated condition monitoring system for motor-operated valves used in nuclear power plants. The methodology used in this project is based on the electric motor power signatures analysis, during the closing and opening stroke time of the valve. Once the measurements baseline diagnostic of the motor-operated valve is taken, it is possible to detect long-term deviations during valve lifetime, detecting in advance valve failures. The system implements two parallel techniques for detection and categorization of anomalies: expert system using fuzzy logic based on rules and knowledge base, providing a systematic approach for decision making, and the Wavelet Transform Technique, where the main goal is to obtain more detailed information contained in the measured data, identifying and characterizing the transients phenomena in the time and frequency domains, correlating them to failures situations in the incipient stage. The conditioning monitoring and diagnostic system was designed and implemented at

  16. Fuel rod failure detection method and system

    International Nuclear Information System (INIS)

    Assmann, H.; Janson, W.; Stehle, H.; Wahode, P.

    1975-01-01

    The inventor claims a method for the detection of a defective fuel rod cladding tube or of inleaked water in the cladding tube of a fuel rod in the fuel assembly of a pressurized-water reactor. The fuel assembly is not disassembled but examined as a whole. In the examination, the cladding tube is heated near one of its two end plugs, e.g. with an attached high-frequency inductor. The water contained in the cladding tube evaporates, and steam bubbles or a condensate are detected by the ultrasonic impulse-echo method. It is also possible to measure the delay of the temperature rise at the end plug or to determine the cooling energy required to keep the end plug temperature stable and thus to detect water ingression. (DG/AK) [de

  17. Operation safety of control systems. Principles and methods

    International Nuclear Information System (INIS)

    Aubry, J.F.; Chatelet, E.

    2008-01-01

    This article presents the main operation safety methods that can be implemented to design safe control systems taking into account the behaviour of the different components with each other (binary 'operation/failure' behaviours, non-consistent behaviours and 'hidden' failures, dynamical behaviours and temporal aspects etc). To take into account these different behaviours, advanced qualitative and quantitative methods have to be used which are described in this article: 1 - qualitative methods of analysis: functional analysis, preliminary risk analysis, failure mode and failure effects analyses; 2 - quantitative study of systems operation safety: binary representation models, state space-based methods, event space-based methods; 3 - application to the design of control systems: safe specifications of a control system, qualitative analysis of operation safety, quantitative analysis, example of application; 4 - conclusion. (J.S.)

  18. Enhancement of Electroluminescence (EL) image measurements for failure quantification methods

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Enhanced quality images are necessary for EL image analysis and failure quantification. A method is proposed which determines image quality in terms of more accurate failure detection of solar panels through electroluminescence (EL) imaging technique. The goal of the paper is to determine the most...

  19. Monitoring human and organizational factors influencing common-cause failures of safety-instrumented system during the operational phase

    International Nuclear Information System (INIS)

    Rahimi, Maryam; Rausand, Marvin

    2013-01-01

    Safety-instrumented systems (SISs) are important safety barriers in many technical systems in the process industry. Reliability requirements for SISs are specified as a safety integrity level (SIL) with reference to the standard IEC 61508. The SIS reliability is often threatened by common-cause failures (CCFs), and the beta-factor model is the most commonly used model for incorporating the effects of CCFs. In the design phase, the beta-factor, β, is determined by answering a set of questions that is given in part 6 of IEC 61508. During the operational phase, there are several factors that influence β, such that the actual β differs from what was predicted in the design phase, and therefore the required reliability may not be maintained. Among the factors influencing β in the operational phase are human and organizational factors (HOFs). A number of studies within industries that require highly reliable products have shown that HOFs have significant influence on CCFs and therefore on β in the operational phase, but this has been neglected in the process industry. HOFs are difficult to predict, and susceptible to be changed during the operational phase. Without proper management, changing HOFs may cause the SIS reliability to drift out of its required value. The aim of this article is to highlight the importance of HOFs in estimation of β for SISs, and also to propose a framework to follow the HOFs effects and to manage them such that the reliability requirement can be maintained

  20. Effects of autologous bone marrow stem cell transplantation on beta-adrenoceptor density and electrical activation pattern in a rabbit model of non-ischemic heart failure

    Directory of Open Access Journals (Sweden)

    Ullmann Cris

    2006-06-01

    Full Text Available Abstract Background Since only little is known on stem cell therapy in non-ischemic heart failure we wanted to know whether a long-term improvement of cardiac function in non-ischemic heart failure can be achieved by stem cell transplantation. Methods White male New Zealand rabbits were treated with doxorubicine (3 mg/kg/week; 6 weeks to induce dilative non-ischemic cardiomyopathy. Thereafter, we obtained autologous bone marrow stem cells (BMSC and injected 1.5–2.0 Mio cells in 1 ml medium by infiltrating the myocardium via a left anterolateral thoracotomy in comparison to sham-operated rabbits. 4 weeks later intracardiac contractility was determined in-vivo using a Millar catheter. Thereafter, the heart was excised and processed for radioligand binding assays to detect β1- and β2-adrenoceptor density. In addition, catecholamine plasma levels were determined via HPLC. In a subgroup we investigated cardiac electrophysiology by use of 256 channel mapping. Results In doxorubicine-treated animals β-adrenoceptor density was significantly down-regulated in left ventricle and septum, but not in right ventricle, thereby indicating a typical left ventricular heart failure. Sham-operated rabbits exhibited the same down-regulation. In contrast, BMSC transplantation led to significantly less β-adrenoceptor down-regulation in septum and left ventricle. Cardiac contractility was significantly decreased in heart failure and sham-operated rabbits, but was significantly higher in BMSC-transplanted hearts. Norepinephrine and epinephrine plasma levels were enhanced in heart failure and sham-operated animals, while these were not different from normal in BMSC-transplanted animals. Electrophysiological mapping revealed unaltered electrophysiology and did not show signs of arrhythmogeneity. Conclusion BMSC transplantation improves sympathoadrenal dysregualtion in non-ischemic heart failure.

  1. Proactive restoration of slow-failures in optical networks

    DEFF Research Database (Denmark)

    Siracusa, Domenico; Pederzolli, Federico; Salvadori, Elio

    2014-01-01

    Current optical networks, while offering outstanding reliability, still suffer from occasional failures. A resource-efficient procedure to handle these failures in un-protected scenarios is to perform restoration, i.e., to dynamically setup a backup lightpath after the primary one stops working......, which leads to traffic losses while such operation completes. In this paper we propose a technique, applicable to optical networks with centralized control, to better handle failures with slow transients. The idea is to proactively perform the backup lightpath's setup, triggered by either a fixed...

  2. Surveillance and fault diagnosis for power plants in the Netherlands: operational experience

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.; Hagen, T.H.J.J. van der

    1998-01-01

    Nuclear Power Plant (NPP) surveillance and fault diagnosis systems in Dutch Borssele (PWR) and Dodewaard (BWR) power plants are summarized. Deterministic and stochastic models and artificial intelligence (AI) methodologies effectively process the information from the sensors. The processing is carried out by means of methods and algorithms that are collectively referred to Power Reactor Noise Fault Diagnosis. Two main schemes used are failure detection and instrument fault detection. In addition to conventional and advanced modern fault diagnosis methodologies involved, also the applications of emerging technologies in Dutch reactors are given and examples from operational experience are presented. (author)

  3. Remote monitoring of heart failure: benefits for therapeutic decision making.

    Science.gov (United States)

    Martirosyan, Mihran; Caliskan, Kadir; Theuns, Dominic A M J; Szili-Torok, Tamas

    2017-07-01

    Chronic heart failure is a cardiovascular disorder with high prevalence and incidence worldwide. The course of heart failure is characterized by periods of stability and instability. Decompensation of heart failure is associated with frequent and prolonged hospitalizations and it worsens the prognosis for the disease and increases cardiovascular mortality among affected patients. It is therefore important to monitor these patients carefully to reveal changes in their condition. Remote monitoring has been designed to facilitate an early detection of adverse events and to minimize regular follow-up visits for heart failure patients. Several new devices have been developed and introduced to the daily practice of cardiology departments worldwide. Areas covered: Currently, special tools and techniques are available to perform remote monitoring. Concurrently there are a number of modern cardiac implantable electronic devices that incorporate a remote monitoring function. All the techniques that have a remote monitoring function are discussed in this paper in detail. All the major studies on this subject have been selected for review of the recent data on remote monitoring of HF patients and demonstrate the role of remote monitoring in the therapeutic decision making for heart failure patients. Expert commentary: Remote monitoring represents a novel intensified follow-up strategy of heart failure management. Overall, theoretically, remote monitoring may play a crucial role in the early detection of heart failure progression and may improve the outcome of patients.

  4. Safety related experience in FFTF startup and operation

    International Nuclear Information System (INIS)

    Peterson, R.E.; Halverson, T.G.; Daughtry, J.W.

    1982-06-01

    The Fast Flux Test Facility (FFTF) is a 400 MW(t) sodium cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US LMFBR program. Startup and initial power ascension testing of the facility involved a comprehensive series of readiness reviews and acceptance tests, many of which relate to the inherent safety of the plant. Included are physics measurements, natural circulation, integrated containment leakage, shielding effectiveness, fuel failure detection, and plant protection system tests. Described are the measurements taken to confirm the design safety margins upon which the operating authorization of the plant was based. These measurements demonstrate that large margins of safety are available in the FFTF design

  5. Phased operations and recovery options

    International Nuclear Information System (INIS)

    Mankamo, T.

    1989-01-01

    The event sequence diagram is extended with embedded state submodels. This allows process oriented modeling of phased missions, and flexible modeling of recovery from failure states. This also enhances the structured consideration of time dependences in process conditions, and earlier scenario of events. Operational decision alternatives can straightforwardly be included. In fact, the approach has been developed for the analysis of operational alternatives such as plant shutdown versus continued operation, in failure situations of standby safety systems, with the aim of realistic quantification of shutdown related transient risks

  6. A Big Data Analysis Approach for Rail Failure Risk Assessment.

    Science.gov (United States)

    Jamshidi, Ali; Faghih-Roohi, Shahrzad; Hajizadeh, Siamak; Núñez, Alfredo; Babuska, Robert; Dollevoet, Rolf; Li, Zili; De Schutter, Bart

    2017-08-01

    Railway infrastructure monitoring is a vital task to ensure rail transportation safety. A rail failure could result in not only a considerable impact on train delays and maintenance costs, but also on safety of passengers. In this article, the aim is to assess the risk of a rail failure by analyzing a type of rail surface defect called squats that are detected automatically among the huge number of records from video cameras. We propose an image processing approach for automatic detection of squats, especially severe types that are prone to rail breaks. We measure the visual length of the squats and use them to model the failure risk. For the assessment of the rail failure risk, we estimate the probability of rail failure based on the growth of squats. Moreover, we perform severity and crack growth analyses to consider the impact of rail traffic loads on defects in three different growth scenarios. The failure risk estimations are provided for several samples of squats with different crack growth lengths on a busy rail track of the Dutch railway network. The results illustrate the practicality and efficiency of the proposed approach. © 2017 The Authors Risk Analysis published by Wiley Periodicals, Inc. on behalf of Society for Risk Analysis.

  7. Implant failure in osteosynthesis of fractures of long bones ...

    African Journals Online (AJOL)

    Patients who had open operative treatment of fractures of long bones were reviewed retrospectively to identify the incidence of and risk factors for implant failure. One hundred and five patients had open reduction and internal fixation of 117 fractures of long bones, out of which four patients suffered implant failure.

  8. Operative vaginal delivery in case of persistent occiput posterior position after manual rotation failure: a 6-month follow-up on pelvic floor function.

    Science.gov (United States)

    Guerby, Paul; Parant, Olivier; Chantalat, Elodie; Vayssiere, Christophe; Vidal, Fabien

    2018-05-21

    To compare the short- and long-term perineal consequences (at 6 months postpartum) and short-term neonatal consequences of instrumental rotation (IR) to those induced by assisted delivery (AD) in the occiput posterior (OP) position, in case of manual rotation failure. A prospective observational cohort study; tertiary referral hospital including all women presenting with persistent OP position who delivered vaginally after manual rotation failure with attempted IR or AD in OP position from September 2015 to October 2016. Maternal and neonatal outcomes of all attempted IR deliveries were compared with OP operative vaginal deliveries. Main outcomes measured were pelvic floor function at 6 months postpartum including Wexner score for anal incontinence and ICIQ-FLUTS for urinary symptoms. Perineal morbidity comprised severe perineal tears, corresponding to third and fourth degree lacerations. Fetal morbidity parameters comprised low neonatal Apgar scores, acidaemia, major and minor fetal injuries and neonatal intensive care unit admissions. Among 5265 women, 495 presented with persistent OP positions (9.4%) and 111 delivered after manual rotation failure followed by AD delivery: 58 in the IR group and 53 in the AD in OP group. The incidence of anal sphincter injuries was significantly reduced after IR attempt (1.7% vs. 24.5%; p < 0.001) without increasing neonatal morbidity. At 6 months postpartum, AD in OP position was associated with higher rate of anal incontinence (30% vs. 5.5%, p = 0.001) and with more urinary symptoms, dyspareunia and perineal pain. OP operative deliveries are associated with significant perineal morbidity and pelvic floor dysfunction at 6 months postpartum.

  9. Object and operation supported maintenance for mining equipment

    Directory of Open Access Journals (Sweden)

    Walter Bartelmus

    2014-09-01

    Full Text Available The paper aroused in answer to discussion in Mining Magazine (MM September 2011 and July/August 2013. The paper shows that discussion given in the MM issue July/August 2013 does not fulfill expectations expressed in MM issue 2011. The presented paper is the review on maintenance that is based on condition monitoring as tool for detection of faults and failure prevention. Fault and failure are regarded as inevitable during the machine operation as the process of wear and the process of degradation. The question is, if one can influence the wear and degradation process, using condition monitoring. The paper will present technology (in reference to cited papers which demonstrates that the use of the proper method can influence the wear and machine degradation process, using proper condition monitoring techniques and knowing scenarios of wear and degradation process, the maintenance can be rationalized. The presented paper shows possible improvements which are needed to fulfill expectations expressed in MM September 2011 and they are not taken into consideration in MM July/August 3013. These improvements can be fulfilling on the bases of object and operation supported maintenance.

  10. Single shell tank sluicing history and failure frequency

    International Nuclear Information System (INIS)

    HERTZEL, J.S.

    1998-01-01

    This document assesses the potential for failure of the single-shell tanks (SSTs) that are presumably sound and helps to establish the retrieval priorities for these and the assumed leakers. Furthermore, this report examines probabilities of SST failure as a function of age and operational history, and provides a simple statistical summary of historical leak volumes, leak rates, and corrosion factor

  11. Establishing and sustaining a technical program to achieve zero fuel failures

    International Nuclear Information System (INIS)

    Deshon, J.; Whiteside, K.; Burnham, R.

    2015-01-01

    In 2006, Chief Nuclear Officers (CNOs) of electric utilities operating 103 commercial reactors in the United States (U.S.) formally endorsed an initiative to achieve failure-free fuel performance by the end of 2010. This became known as the Zero-by- Ten Fuel Failure Initiative. The endorsement manifested during a meeting at the Institute of Nuclear Power Operations (INPO) while nuclear fuel performance trends were being reviewed. Declining fuel performance generated backing for the Initiative. This paper provides a brief review of some of the drivers that caused those trends, the Initiative elements designed to address them, and a review of the technical program that helped achieve, and thus far sustain, improved fuel performance. (author) Key Words: Nuclear Fuel, Fuel, Fuel Failures, Fuel Failure Initiative, Zero by Ten Initiative

  12. Failure mode and effects analysis on typical reactor trip system

    International Nuclear Information System (INIS)

    Eisawy, E.A.

    2010-01-01

    An updated failure mode and effects analysis, FMEA , has been performed on a typical reactor trip system. This upgrade helps to avoid system damage and ,as a result, extends the system service life. It also provides for simplified maintenance and surveillance testing. The operating conditions under which the system is to carry out its function and the operational profile expected for the system have been determined. The results of the FMEA have been given in terms of operating states of the subsystem.The results are given in form of table which is set up such that for a given failure one can read across it and determine which items remain operating in the system. From this data one can identify the number of components operating in the system for monitors pressure exceeds the setpoint pressure.

  13. The statistical analysis of failure of a MEVATRON77 DX67 linear accelerator over a ten year period

    CERN Document Server

    Aoyama, H; Tahara, S; Uno, H; Kadohisa, S; Azuma, Y; Nakagiri, Y; Hiraki, Y

    2003-01-01

    A linear accelerator (linac) takes a leading role in radiation therapy. A linac consists of complicated main parts and systems and it is required that highly accurate operational procedures should be maintained. Operational failure occurs for various reasons. In this report, the failure occurrences of one linac over a ten year period were recorded and analyzed. The subject model was a MEVATRON77 DX67 (Siemens, Inc). The failure rate for each system, the form classification of the contents of failure, the operation situation at the time of failure, and the average performance life of the main parts were totaled. Moreover, the relation between the number of therapies that patients received (operating efficiency) and the failure rate within that number and the relation between environment (temperature and humidity) and the failure rate attributed to other systems were analyzed. In this report, irradiation interruption was also included with situations where treatment was unable to begin in total for the number o...

  14. Failure analysis of medical Linac (LMR-15)

    International Nuclear Information System (INIS)

    Kato, Kiyotaka; Nakamura, Katsumi; Ogihara, Kiyoshi; Takahashi, Katsuhiko; Sato, Kazuhisa.

    1994-01-01

    In August 1978, Linac (LMR-15, Z4 Toshiba) was installed at our hospital and in use for 12 years up to September 1990. Recently, we completed working and failure records on this apparatus during the 12-year period, for the purpose of their analysis in the basis of reliability engineering. The results revealed operation rate of 97.85% on the average, mean time between failures (MTBF) from 40-70 hours about the beginning of its working to 280 hours for 2 years before renewal and practically satisfactory values of mean life of parts of life such as magnetron, thyratron and electron gun; the above respective values proved to be above those reported by other literature. On the other hand, we classified, by occurring system, the contents of failures in the apparatus and determined the number of failures and the temperature and humidities in case of failures to examine the correlation between the working environment and failure. The results indicated a change in humidity to gain control of failures in the dosimetric system, especially the monitoring chamber and we could back up the strength of the above correlation from a coefficient of correlation value of 0.84. (author)

  15. Analysis of leak and break behavior in a failure assessment diagram for carbon steel pipes

    International Nuclear Information System (INIS)

    Kanno, Satoshi; Hasegawa, Kunio; Shimizu, Tasuku; Saitoh, Takashi; Gotoh, Nobuho

    1992-01-01

    The leak and break behavior of a cracked coolant pipe subjected to an internal pressure and a bending moment was analyzed with a failure assessment diagram using the R6 approach. This paper examines the conditions of the detectable coolant leakage without breakage. A leakage assessment curve, a locus of assessment point for detectable coolant leakage, was defined in the failure assessment diagram. The region between the leak assessment and failure assessment curves satisfies the condition of detectable leakage without breakage. In this region, a crack can be safely inspected by a coolant leak detector. (orig.)

  16. Computer-aided operations engineering with integrated models of systems and operations

    Science.gov (United States)

    Malin, Jane T.; Ryan, Dan; Fleming, Land

    1994-01-01

    CONFIG 3 is a prototype software tool that supports integrated conceptual design evaluation from early in the product life cycle, by supporting isolated or integrated modeling, simulation, and analysis of the function, structure, behavior, failures and operation of system designs. Integration and reuse of models is supported in an object-oriented environment providing capabilities for graph analysis and discrete event simulation. Integration is supported among diverse modeling approaches (component view, configuration or flow path view, and procedure view) and diverse simulation and analysis approaches. Support is provided for integrated engineering in diverse design domains, including mechanical and electro-mechanical systems, distributed computer systems, and chemical processing and transport systems. CONFIG supports abstracted qualitative and symbolic modeling, for early conceptual design. System models are component structure models with operating modes, with embedded time-related behavior models. CONFIG supports failure modeling and modeling of state or configuration changes that result in dynamic changes in dependencies among components. Operations and procedure models are activity structure models that interact with system models. CONFIG is designed to support evaluation of system operability, diagnosability and fault tolerance, and analysis of the development of system effects of problems over time, including faults, failures, and procedural or environmental difficulties.

  17. Acoustic feedwater heater leak detection: Industry application of low ampersand high frequency detection increases response and reliability

    International Nuclear Information System (INIS)

    Woyshner, W.S.; Bryson, T.; Robertson, M.O.

    1993-01-01

    The Electric Power Research Institute has sponsored research associated with acoustic Feedwater Heater Leak Detection since the early 1980s. Results indicate that this technology is economically beneficial and dependable. Recent research work has employed acoustic sensors and signal conditioning with wider frequency range response and background noise elimination techniques to provide increased accuracy and dependability. Dual frequency sensors have been applied at a few facilities to provide information on this application of dual frequency response. Sensor mounting methods and attenuation due to various mounting configurations are more conclusively understood. These are depicted and discussed in detail. The significance of trending certain plant parameters such as heat cycle flows, heater vent and drain valve position, proper relief valve operation, etc. is also addressed. Test data were collected at various facilities to monitor the effect of varying several related operational parameters. A group of FWHLD Users have been involved from the inception of the project and reports on their latest successes and failures, along with various data depicting early detection of FWHLD tube leaks, will be included. 3 refs., 12 figs., 1 tab

  18. Formation of failure matrix and failure–free control algorithm for multi–sectioned Switched–reluctance drive

    International Nuclear Information System (INIS)

    Odnokopylov, G; Rozayev, I

    2014-01-01

    We review fault-tolerant switched reluctance drive with sectioning of the three–phase stator winding. In the operating process of an electric drive, there will be continuous monitoring of the operating state on the basis of a developed algorithm to analyse drive operability and formation tabulate a failure matrix. The paper introduces a failure–free control algorithm for multi–section switch – reluctance motor with formation the assignment values of amplitude phase currents taking into account the failure matrix. We show that in an emergency such single failure or multiple failure in switched–reluctance drive it is possible to provide reduction of torque fall and pro–gressively stock depletion with providing fault–tolerance of drive system. A method of residual life evaluation is proposed on the basis of calculating the coefficient of operability of the electric drive system that gives possibility to control the endurance of electric drive in real time from operational to completely unusable

  19. A study on reactor core failure thresholds to safety operation of LMFBR

    International Nuclear Information System (INIS)

    Kazuo, Haga; Hiroshi, Endo; Tomoko, Ishizu; Yoshihisa, Shindo

    2006-01-01

    Japan Nuclear Safety Organization (JNES) has been developing the methodology and computer codes for applying level-1 PSA to LMFBR. Many of our efforts have been directed to the judging conditions of reactor core damage and the time allowed to initiate the accident management. Several candidates of the reactor core failure threshold were examined to a typical proto-type LMFBR with MOX fuel based on the plant thermal-hydraulic analyses to the actual progressions leading to the core damage. The results of the present study showed that the judging condition of coolant-boundary integrity failure, 750 degree-C of the boundary temperature, is enough as the threshold of core damage to PLOHS (protected loss-of-heat sink). High-temperature fuel cladding creep failure will not take place before the coolant-boundary reaches the judging temperature and sodium boiling will not occur due to the system pressure rise. In cases of ATWS (anticipated transient without scrum) the accident progression is so fast and the reactor core damage will be inevitable even a realistic negative reactivity insertion due to the temperature rise is considered. Only in the case of ULOHS (unprotected loss-of-heat sink) a relatively long time of 11 min will be allowed till the shut-down of the reactor before the core damage. (authors)

  20. Evaluation of the behavior of waterlogged fuel rod failures in LWRs

    International Nuclear Information System (INIS)

    Siegel, B.

    1977-11-01

    A summary of the available information on waterlogged fuel rod failures is presented. The information includes experimental results from waterlogging tests in research reactors, observations of waterlogging failures in commercial reactors, and reactor vendor assessments. It is concluded that (a) operating restrictions to reduce pellet/cladding interactions also reduce the potential for waterlogging failures during transients, (b) tests to simulate accident conditions produced the worst waterlogging failures, and (c) there is no apparent threat from waterlogging failures to the overall coolability of the core or to safe reactor shutdown

  1. Failure Analysis of High-Power Piezoelectric Transducers

    National Research Council Canada - National Science Library

    Gabrielson, T. B

    2005-01-01

    ... and stress in a piezoelectric material. For a transducer operated near resonance, there will be "hot spots" or regions of locally intense stress and electric field that precipitate premature failure...

  2. Estimation of regulated term of technical systems further operation

    International Nuclear Information System (INIS)

    Strel'nikov, V.P.

    2008-01-01

    The technique of estimating the regulated term of technical systems further operation on the basis of data on failures during operation and use of probabilistic-physical model of failures (DN-distribution) is proposed

  3. Real-time monitoring for detection of retained surgical sponges and team motion in the surgical operation room using radio-frequency-identification (RFID) technology: a preclinical evaluation.

    Science.gov (United States)

    Kranzfelder, Michael; Zywitza, Dorit; Jell, Thomas; Schneider, Armin; Gillen, Sonja; Friess, Helmut; Feussner, Hubertus

    2012-06-15

    Technical progress in the surgical operating room (OR) increases constantly, facilitating the development of intelligent OR systems functioning as "safety backup" in the background of surgery. Precondition is comprehensive data retrieval to identify imminent risky situations and inaugurate adequate security mechanisms. Radio-frequency-identification (RFID) technology may have the potential to meet these demands. We set up a pilot study investigating feasibility and appliance reliability of a stationary RFID system for real-time surgical sponge monitoring (passive tagged sponges, position monitoring: mayo-stand/abdominal situs/waste bucket) and OR team tracking (active transponders, position monitoring: right/left side of OR table). In vitro: 20/20 sponges (100%) were detected on the mayo-stand and within the OR-phantom, however, real-time detection accuracy declined to 7/20 (33%) when the tags were moved simultaneously. All retained sponges were detected correctly. In vivo (animal): 7-10/10 sterilized sponges (70%-100%) were detected correctly within the abdominal cavity. OR-team: detection accuracy within the OR (surveillance antenna) and on both sides of the OR table (sector antenna) was 100%. Mean detection time for position change (left to right side and contrariwise) was 30-60 s. No transponder failure was noted. This is the first combined RFID system that has been developed for stationary use in the surgical OR. Preclinical evaluation revealed a reliable sponge tracking and correct detection of retained textiles (passive RFID) but also demonstrated feasibility of comprehensive data acquisition of team motion (active RFID). However, detection accuracy needs to be further improved before implementation into the surgical OR. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Evaluation of a protocol for the non-operative management of perforated peptic ulcer.

    Science.gov (United States)

    Marshall, C; Ramaswamy, P; Bergin, F G; Rosenberg, I L; Leaper, D J

    1999-01-01

    The non-operative management of perforated peptic ulcer has previously been shown to be both safe and effective although it remains controversial. A protocol for non-operative management was set up in this hospital in 1989. Adherence to the guidelines in the protocol has been audited over a 6-year period with a review of outcome. The case-notes of patients with a diagnosis of perforated peptic ulcer were reviewed. Twelve guidelines from the protocol were selected for evaluation of compliance to the protocol. Forty-nine patients underwent non-operative treatment initially. Eight patients failed to respond and underwent operation. Complications included abscess formation (seven patients), renal failure (one), gastric ileus (one), chest infection (two), and cardiac failure and stroke (one). Four deaths occurred in this group. Adherence to certain protocol guidelines was poor, notably those concerning prevention of thromboembolism, use of antibiotics, use of contrast examination to confirm the diagnosis and referral for follow-up endoscopy. Two gastric cancers were detected on subsequent endoscopy. This experience demonstrates that non-operative treatment can be used successfully in a general hospital. Adherence to protocol guidelines was found to be variable and the protocol has therefore been simplified. This study highlights the need for an accurate diagnosis and the importance of follow-up endoscopy.

  5. Failure modes and effects analysis (FMEA) for Gamma Knife radiosurgery.

    Science.gov (United States)

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Flickinger, John; Arai, Yoshio; Vacsulka, Jonet; Feng, Wenzheng; Monaco, Edward; Niranjan, Ajay; Lunsford, L Dade; Huq, M Saiful

    2017-11-01

    Gamma Knife radiosurgery is a highly precise and accurate treatment technique for treating brain diseases with low risk of serious error that nevertheless could potentially be reduced. We applied the AAPM Task Group 100 recommended failure modes and effects analysis (FMEA) tool to develop a risk-based quality management program for Gamma Knife radiosurgery. A team consisting of medical physicists, radiation oncologists, neurosurgeons, radiation safety officers, nurses, operating room technologists, and schedulers at our institution and an external physicist expert on Gamma Knife was formed for the FMEA study. A process tree and a failure mode table were created for the Gamma Knife radiosurgery procedures using the Leksell Gamma Knife Perfexion and 4C units. Three scores for the probability of occurrence (O), the severity (S), and the probability of no detection for failure mode (D) were assigned to each failure mode by 8 professionals on a scale from 1 to 10. An overall risk priority number (RPN) for each failure mode was then calculated from the averaged O, S, and D scores. The coefficient of variation for each O, S, or D score was also calculated. The failure modes identified were prioritized in terms of both the RPN scores and the severity scores. The established process tree for Gamma Knife radiosurgery consists of 10 subprocesses and 53 steps, including a subprocess for frame placement and 11 steps that are directly related to the frame-based nature of the Gamma Knife radiosurgery. Out of the 86 failure modes identified, 40 Gamma Knife specific failure modes were caused by the potential for inappropriate use of the radiosurgery head frame, the imaging fiducial boxes, the Gamma Knife helmets and plugs, the skull definition tools as well as other features of the GammaPlan treatment planning system. The other 46 failure modes are associated with the registration, imaging, image transfer, contouring processes that are common for all external beam radiation therapy

  6. Fission product concentration evolution in sodium pool following a fuel subassembly failure in an LMFBR

    International Nuclear Information System (INIS)

    Natesan, K.; Velusamy, K.; Selvaraj, P.; Kasinathan, N.; Chellapandi, P.; Chetal, S.; Bhoje, S.

    2003-01-01

    During a fuel element failure in a liquid metal cooled fast breeder reactor, the fission products originating from the failed pins mix into the sodium pool. Delayed Neutron Detectors (DND) are provided in the sodium pool to detect such failures by way of detection of delayed neutrons emitted by the fission products. The transient evolution of fission product concentration is governed by the sodium flow distribution in the pool. Transient hydraulic analysis has been carried out using the CFD code PHOENICS to estimate fission product concentration evolution in hot pool. k- ε turbulence model and zero laminar diffusivity for the fission product concentration have been considered in the analysis. Times at which the failures of various fuel subassemblies (SA) are detected by the DND are obtained. It has been found that in order to effectively detect the failure of every fuel SA, a minimum of 8 DND in hot pool are essential

  7. Investigating for failure of central ventilation fan blade

    International Nuclear Information System (INIS)

    Koo, Jae Raeyang; Ko Woo Sig; Kim, Yeon Hwan; Park, Kwang Ha

    2002-01-01

    During the operation, central ventilation fan stopped when switch 'on' condition. When central ventilation fan disassemble, ten blades of fan fractured. We have searched cause of failure. We had modeling one of the fan blades and analysis with computer programs. Thus we have find that fracture of central ventilation fan blades is alternative stress and vibration at hub. In this paper, we have described cause of failure

  8. Diagnostic device for failures in control rod drives

    International Nuclear Information System (INIS)

    Okutani, Tetsuro.

    1982-01-01

    Purpose: To enable to concretely point out a failure position when a failure might occur by diagnosing the failure without affecting the variation to the state of a reactor core. Constitution: A frequency switching circuit is provided in an inverter for controlling the rotating speed of a motor for discharging and charging a control rod. Then, a voltage detector is provided at asemiconductor switch provided between the inverter and the motor. When a high frequency control signal is input to the inverter in diagnosing a failure, the switching speed of the switch is accelerated, a current hardly flows through the motor, and even if the inverter is operated, the motor will not rotate. Thus, the failure of a control rod drive can be diagnosed without affecting any influence to the state of a reactor core. (Kamimura, M.)

  9. Reliability model for common mode failures in redundant safety systems

    International Nuclear Information System (INIS)

    Fleming, K.N.

    1974-12-01

    A method is presented for computing the reliability of redundant safety systems, considering both independent and common mode type failures. The model developed for the computation is a simple extension of classical reliability theory. The feasibility of the method is demonstrated with the use of an example. The probability of failure of a typical diesel-generator emergency power system is computed based on data obtained from U. S. diesel-generator operating experience. The results are compared with reliability predictions based on the assumption that all failures are independent. The comparison shows a significant increase in the probability of redundant system failure, when common failure modes are considered. (U.S.)

  10. The moral failure of the patriarchy.

    Science.gov (United States)

    Watson, J

    1990-01-01

    The present health care system operates within a larger structure that now has to be openly acknowledged as patriarchal: Caring is viewed as women's work, which is not valued and which is considered less important than the work of men. The moral failure of this worldview is evident in such health care crises as care of the homelessness and those with AIDS, and dramatic rises in rates of infant mortality among the poor. This failure demands a health care revolution--a revolution in the sense that society must give up that which no longer works.

  11. The Spectrum of Renal Allograft Failure.

    Directory of Open Access Journals (Sweden)

    Sourabh Chand

    Full Text Available Causes of "true" late kidney allograft failure remain unclear as study selection bias and limited follow-up risk incomplete representation of the spectrum.We evaluated all unselected graft failures from 2008-2014 (n = 171; 0-36 years post-transplantation by contemporary classification of indication biopsies "proximate" to failure, DSA assessment, clinical and biochemical data.The spectrum of graft failure changed markedly depending on the timing of allograft failure. Failures within the first year were most commonly attributed to technical failure, acute rejection (with T-cell mediated rejection [TCMR] dominating antibody-mediated rejection [ABMR]. Failures beyond a year were increasingly dominated by ABMR and 'interstitial fibrosis with tubular atrophy' without rejection, infection or recurrent disease ("IFTA". Cases of IFTA associated with inflammation in non-scarred areas (compared with no inflammation or inflammation solely within scarred regions were more commonly associated with episodes of prior rejection, late rejection and nonadherence, pointing to an alloimmune aetiology. Nonadherence and late rejection were common in ABMR and TCMR, particularly Acute Active ABMR. Acute Active ABMR and nonadherence were associated with younger age, faster functional decline, and less hyalinosis on biopsy. Chronic and Chronic Active ABMR were more commonly associated with Class II DSA. C1q-binding DSA, detected in 33% of ABMR episodes, were associated with shorter time to graft failure. Most non-biopsied patients were DSA-negative (16/21; 76.1%. Finally, twelve losses to recurrent disease were seen (16%.This data from an unselected population identifies IFTA alongside ABMR as a very important cause of true late graft failure, with nonadherence-associated TCMR as a phenomenon in some patients. It highlights clinical and immunological characteristics of ABMR subgroups, and should inform clinical practice and individualised patient care.

  12. Usefulness of multimodality imaging for detection of myocardial infarction in patients with advanced kidney failure: case report

    Energy Technology Data Exchange (ETDEWEB)

    Veras, Mariana Ferreira; Azevedo, Jader Cunha de; Gamarski, Moisés; Mesquita, Evandro Tinoco; Mesquita, Cláudio Tinoco, E-mail: fvmari@gmail.com [Hospital Procardíaco, Rio de Janeiro, RJ (Brazil); Alves, José Galvão [Centro Universitário de Volta Redonda, RJ (Brazil)

    2016-01-15

    The third universal definition of acute myocardial infarction (AMI) is based on the elevation of troponin in association with ischemic symptoms, electrocardiographic changes and imaging findings. In patients with chest pain, the diagnosis of AMI is performed by dosing serum markers of myocardial necrosis, particularly troponins, by means of changes in 12 - lead electrocardiogram (ECG) or by identifying changes in the contractile dynamics of the left ventricle to the transthoracic echocardiogram. In some cases, confounding factors may hamper the diagnosis, such as: (a) presence of previous changes in the baseline ECG, especially LBBB; (b) elevations of myocardial necrosis markers (MNM) resulting from situations other than AMI and; (c) old changes in contractility detected by transthoracic ECG. Serum cardiac troponin (Tn) is the most specific and most used MNM for the diagnosis of AMI. Nevertheless, in some situations troponin elevation may not be due to an AMI, as in cases of acute pulmonary embolism, acute pericarditis, severe heart failure, myocarditis, and sepsis and kidney failure. Patients with kidney failure have high probability of concurrent cardiovascular disease. Furthermore, the cross-reacting proteins interfering with skeletal muscle, analytical imprecision and interactions with the dialysis membrane may cause elevation of troponin in 7% to 17% of patients with kidney failure. When in doubt about diagnosis of AMI, {sup 99m}Technetium pyrophosphate myocardial scintigraphy ({sup 99m}Tc-PYP) stands out as a noninvasive method capable of identifying areas of myocardial necrosis, thus helping in the diagnosis of AMI. {sup 99m}Tc-labeled phosphonate agents undergo chemical absorption with calcium. A large influx of calcium occurs during the evolutionary process of AMI. The calcium flows into the intracellular space and myocardial concentration of {sup 99m}Tc-PYP follows such increase, with a maximum peak uptake about 48 to 72 hours after the acute event. The

  13. Operational NDT simulator, towards human factors integration in simulated probability of detection

    Science.gov (United States)

    Rodat, Damien; Guibert, Frank; Dominguez, Nicolas; Calmon, Pierre

    2017-02-01

    In the aeronautic industry, the performance demonstration of Non-Destructive Testing (NDT) procedures relies on Probability Of Detection (POD) analyses. This statistical approach measures the ability of the procedure to detect a flaw with regard to one of its characteristic dimensions. The inspection chain is evaluated as a whole, including equipment configuration, probe effciency but also operator manipulations. Traditionally, a POD study requires an expensive campaign during which several operators apply the procedure on a large set of representative samples. Recently, new perspectives for the POD estimation have been introduced using NDT simulation to generate data. However, these approaches do not offer straightforward solutions to take the operator into account. The simulation of human factors, including cognitive aspects, often raises questions. To address these diffculties, we propose a concept of operational NDT simulator [1]. This work presents the first steps in the implementation of such simulator for ultrasound phased array inspection of composite parts containing Flat Bottom Holes (FBHs). The final system will look like a classical ultrasound testing equipment with a single exception: the displayed signals will be synthesized. Our hardware (ultrasound acquisition card, 3D position tracker) and software (position analysis, inspection scenario, synchronization, simulations) environments are developed as a bench to test the meta-modeling techniques able to provide fast-simulated realistic ultra-sound signals. The results presented here are obtained by on-the-fly merging of real and simulated signals. They confirm the feasibility of our approach: the replacement of real signals by purely simulated ones has been unnoticed by operators. We believe this simulator is a great prospect for POD evaluation including human factors, and may also find applications for training or procedure set-up.

  14. Fuel-element failures in Hanford single-pass reactors 1944--1971

    Energy Technology Data Exchange (ETDEWEB)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy`s (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report.

  15. A statistical analysis of pellet-clad interaction failures in water reactor fuel

    International Nuclear Information System (INIS)

    McDonald, S.G.; Fardo, R.D.; Sipush, P.J.; Kaiser, R.S.

    1981-01-01

    The primary objective of the statistical analysis was to develop a mathematical function that would predict PCI fuel rod failures as a function of the imposed operating conditions. Linear discriminant analysis of data from both test and commercial reactors was performed. The initial data base used encompassed 713 data points (117 failures and 596 non-failures) representing a wide variety of water cooled reactor fuel (PWR, BWR, CANDU, and SGHWR). When applied on a best-estimate basis, the resulting function simultaneously predicts approximately 80 percent of both the failure and non-failure data correctly. One of the most significant predictions of the analysis is that relatively large changes in power can be tolerated when the pre-ramp irradiation power is low, but that only small changes in power can be tolerated when the pre-ramp irradiation power is high. However, it is also predicted that fuel rods irradiated at low power will fail at lower final powers than those irradiated at high powers. Other results of the analysis are that fuel rods with high clad operating temperatures can withstand larger power increases that fuel rods with low clad operating temperatures, and that burnup has only a minimal effect on PCI performance after levels of approximately 10000 MWD/MTU have been exceeded. These trends in PCI performance and the operating parameters selected are believed to be consistent with mechanistic considerations. Published PCI data indicate that BWR fuel usually operates at higher local powers and changes in power, lower clad temperatures, and higher local ramp rates than PWR fuel

  16. HIV resistance testing and detected drug resistance in Europe

    DEFF Research Database (Denmark)

    Schultze, Anna; Phillips, Andrew N; Paredes, Roger

    2015-01-01

    to Southern Europe. CONCLUSIONS: Despite a concurrent decline in virological failure and testing, drug resistance was commonly detected. This suggests a selective approach to resistance testing. The regional differences identified indicate that policy aiming to minimize the emergence of resistance......OBJECTIVES: To describe regional differences and trends in resistance testing among individuals experiencing virological failure and the prevalence of detected resistance among those individuals who had a genotypic resistance test done following virological failure. DESIGN: Multinational cohort...... study. METHODS: Individuals in EuroSIDA with virological failure (>1 RNA measurement >500 on ART after >6 months on ART) after 1997 were included. Adjusted odds ratios (aORs) for resistance testing following virological failure and aORs for the detection of resistance among those who had a test were...

  17. (m, M) Machining system with two unreliable servers, mixed spares and common-cause failure

    OpenAIRE

    Jain, Madhu; Mittal, Ragini; Kumari, Rekha

    2015-01-01

    This paper deals with multi-component machine repair model having provision of warm standby units and repair facility consisting of two heterogeneous servers (primary and secondary) to provide repair to the failed units. The failure of operating and standby units may occur individually or due to some common cause. The primary server may fail partially following full failure whereas secondary server faces complete failure only. The life times of servers and operating/standby units and their re...

  18. Design and Control of Small Neutral Beam Arc Chamber for Investigations of DIII-D Neutral Beam Failure During Helium Operation

    Science.gov (United States)

    Fremlin, Carl; Beckers, Jasper; Crowley, Brendan; Rauch, Joseph; Scoville, Jim

    2017-10-01

    The Neutral Beam system on the DIII-D tokamak consists of eight ion sources using the Common Long Pulse Source (CLPS) design. During helium operation, desired for research regarding the ITER pre-nuclear phase, it has been observed that the ion source arc chamber performance steadily deteriorates, eventually failing due to electrical breakdown of the insulation. A significant investment of manpower and time is required for repairs. To study the cause of failure a small analogue of the DIII-D neutral beam arc chamber has been constructed. This poster presents the design and analysis of the arc chamber including the PLC based operational control system for the experiment, analysis of the magnetic confinement and details of the diagnostic suite. Work supported in part by US DoE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698.

  19. A Test Bed for Short Pulse OA Detection of Optical Directors in Amphibious Operations

    National Research Council Canada - National Science Library

    Ertem, M

    1999-01-01

    ...) system to detect optical directors of potential threats in amphibious operations. The use of a short pulse duration allows discrimination of retroreflections from natural sources such as rock formations and vegetation...

  20. Systematic Assessment of Neutron and Gamma Backgrounds Relevant to Operational Modeling and Detection Technology Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, Daniel E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Johnson, Jeffrey O. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nicholson, Andrew D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patton, Bruce W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Peplow, Douglas E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ayaz-Maierhafer, Birsen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This report summarizes the findings of a two year effort to systematically assess neutron and gamma backgrounds relevant to operational modeling and detection technology implementation. The first year effort focused on reviewing the origins of background sources and their impact on measured rates in operational scenarios of interest. The second year has focused on the assessment of detector and algorithm performance as they pertain to operational requirements against the various background sources and background levels.

  1. A Study on the Operator Decision Support for Feed-and-Bleed Operation

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kim, Sang Ho; Kang, Hyun Gook; Yoon, Ho Joon

    2014-01-01

    In the case of a combined accident that includes a failure of the secondary cooling system, it is difficult for operators to recognize the necessity of an feed and bleed (F and B) operation because a lot of parameters and alarms should be checked before a decision, and operators may spend a considerable amount of time arriving at the entry for a proper emergency operating procedure that contains the procedure for an F and B operation. Therefore, a clear identification of the success boundary of an F and B operation would help operators in their decision-making when a combined accident that includes a secondary cooling system failure occurs. This study will provide a useful guideline for the initiation of an F and B operation for operators. Cooling the RCS after a scram is one of the most important safety functions for preventing core damage. To support the operator in decision making whether to initiate the F and B operation, plant conditions requiring the initiation of an F and B operation were identified. Plant conditions are affected by the steam generator inventory, RCS inventory, core inventory, and safety injection availability. The combination of accident types, component availabilities, and the initiation time of an F and B operation affect the success of the F and B operation. Operators need clear information about the RCS condition when the steam generators, the RCS's main residual heat removal mechanism, become unavailable. When this happens, the initiation of an F and B operation becomes necessary. As the number of the state increases, the necessity of an F and B operation increases. Especially, the operator should initiate an F and B operation when the RCS condition enters State 3 for Type 1 incidents or State 3-2 for Type 2 incidents. The results of this study may be useful in providing information regarding the necessity and effects of an F and B operation in a quantitative manner. In particular, in the case of a combined accident including a

  2. Frequency Analysis of Failure Scenarios from Shale Gas Development.

    Science.gov (United States)

    Abualfaraj, Noura; Gurian, Patrick L; Olson, Mira S

    2018-04-29

    This study identified and prioritized potential failure scenarios for natural gas drilling operations through an elicitation of people who work in the industry. A list of twelve failure scenarios of concern was developed focusing on specific events that may occur during the shale gas extraction process involving an operational failure or a violation of regulations. Participants prioritized the twelve scenarios based on their potential impact on the health and welfare of the general public, potential impact on worker safety, how well safety guidelines protect against their occurrence, and how frequently they occur. Illegal dumping of flowback water, while rated as the least frequently occurring scenario, was considered the scenario least protected by safety controls and the one of most concern to the general public. In terms of worker safety, the highest concern came from improper or inadequate use of personal protective equipment (PPE). While safety guidelines appear to be highly protective regarding PPE usage, inadequate PPE is the most directly witnessed failure scenario. Spills of flowback water due to equipment failure are of concern both with regards to the welfare of the general public and worker safety as they occur more frequently than any other scenario examined in this study.

  3. Implementing Operational Analytics using Big Data Technologies to Detect and Predict Sensor Anomalies

    Science.gov (United States)

    Coughlin, J.; Mital, R.; Nittur, S.; SanNicolas, B.; Wolf, C.; Jusufi, R.

    2016-09-01

    Operational analytics when combined with Big Data technologies and predictive techniques have been shown to be valuable in detecting mission critical sensor anomalies that might be missed by conventional analytical techniques. Our approach helps analysts and leaders make informed and rapid decisions by analyzing large volumes of complex data in near real-time and presenting it in a manner that facilitates decision making. It provides cost savings by being able to alert and predict when sensor degradations pass a critical threshold and impact mission operations. Operational analytics, which uses Big Data tools and technologies, can process very large data sets containing a variety of data types to uncover hidden patterns, unknown correlations, and other relevant information. When combined with predictive techniques, it provides a mechanism to monitor and visualize these data sets and provide insight into degradations encountered in large sensor systems such as the space surveillance network. In this study, data from a notional sensor is simulated and we use big data technologies, predictive algorithms and operational analytics to process the data and predict sensor degradations. This study uses data products that would commonly be analyzed at a site. This study builds on a big data architecture that has previously been proven valuable in detecting anomalies. This paper outlines our methodology of implementing an operational analytic solution through data discovery, learning and training of data modeling and predictive techniques, and deployment. Through this methodology, we implement a functional architecture focused on exploring available big data sets and determine practical analytic, visualization, and predictive technologies.

  4. Dynamic loads during failure risk assessment of bridge crane structures

    Science.gov (United States)

    Gorynin, A. D.; Antsev, V. Yu; Shaforost, A. N.

    2018-03-01

    The paper presents the method of failure risk assessment associated with a bridge crane metal structure at the design stage. It also justifies the necessity of taking into account dynamic loads with regard to the operational cycle of a bridge crane during failure risk assessment of its metal structure.

  5. BANK FAILURE PREDICTION WITH LOGISTIC REGRESSION

    Directory of Open Access Journals (Sweden)

    Taha Zaghdoudi

    2013-04-01

    Full Text Available In recent years the economic and financial world is shaken by a wave of financial crisis and resulted in violent bank fairly huge losses. Several authors have focused on the study of the crises in order to develop an early warning model. It is in the same path that our work takes its inspiration. Indeed, we have tried to develop a predictive model of Tunisian bank failures with the contribution of the binary logistic regression method. The specificity of our prediction model is that it takes into account microeconomic indicators of bank failures. The results obtained using our provisional model show that a bank's ability to repay its debt, the coefficient of banking operations, bank profitability per employee and leverage financial ratio has a negative impact on the probability of failure.

  6. Robust facility location: Hedging against failures

    International Nuclear Information System (INIS)

    Hernandez, Ivan; Emmanuel Ramirez-Marquez, Jose; Rainwater, Chase; Pohl, Edward; Medal, Hugh

    2014-01-01

    While few companies would be willing to sacrifice day-to-day operations to hedge against disruptions, designing for robustness can yield solutions that perform well before and after failures have occurred. Through a multi-objective optimization approach this paper provides decision makers the option to trade-off total weighted distance before and after disruptions in the Facility Location Problem. Additionally, this approach allows decision makers to understand the impact on the opening of facilities on total distance and on system robustness (considering the system as the set of located facilities). This approach differs from previous studies in that hedging against failures is done without having to elicit facility failure probabilities concurrently without requiring the allocation of additional hardening/protections resources. The approach is applied to two datasets from the literature

  7. Definition and Classification of Heart Failure

    Directory of Open Access Journals (Sweden)

    Mitja Lainscak

    2017-01-01

    Full Text Available A review of the definition and classification of heart failure, updated since the recent 2016 European Society of Cardiology guidelines for the diagnosis and treatment of acute and chronic heart failure. Heart failure is defined by the European Society of Cardiology (ESC as a clinical syndrome characterised by symptoms such as shortness of breath, persistent coughing or wheezing, ankle swelling and fatigue, that may be accompanied by the following signs: jugular venous pressure, pulmonary crackles, increased heart rate and peripheral oedema. However, these signs may not be present in the early stages and in patients treated with diuretics. When apparent, they are due to a structural and/or functional cardiac abnormality, leading to systolic and/or diastolic ventricular dysfunction, resulting in a reduced cardiac output and/or elevated intra- cardiac pressures at rest or during stress. According to the most recent ESC guidelines the initial evaluation of patients with suspected heart failure should include a clinical history and physical examination, laboratory assessment, chest radiography, and electrocardiography. Echocardiography can confirm the diagnosis. Beyond detecting myocardial abnormality, other impairments such as abnormalities of the valves, pericardium, endocardium, heart rhythm, and conduction may be found. The identification of the underlying aetiology is pivotal for the diagnosis of heart failure and its treatment. The authors review the definitions and classifications of heart failure.

  8. Evaluation of premature failure of a gas turbine component

    CSIR Research Space (South Africa)

    Dedekind, MO

    1996-01-03

    Full Text Available A case study of certain gas turbine stator vanes which fail prematurely is presented, with a view to determining whether operational procedure might have caused the failures. The engines had been operated from a ‘hot-and-high’ environment...

  9. A NEW APPROACH TO DETECT CONGESTIVE HEART FAILURE USING DETRENDED FLUCTUATION ANALYSIS OF ELECTROCARDIOGRAM SIGNALS

    Directory of Open Access Journals (Sweden)

    CHANDRAKAR KAMATH

    2015-02-01

    Full Text Available The aim of this study is to evaluate how far the detrended fluctuation analysis (DFA approach helps to characterize the short-term and intermediate-term fractal correlations in the raw electrocardiogram (ECG signals and thereby discriminate between normal and congestive heart failure (CHF subjects. The DFA-1 calculations were performed on normal and CHF short-term ECG segments, of the order of 20 seconds duration. Differences were found in shortterm and intermediate-term correlation properties and the corresponding scaling exponents of the two groups (normal and CHF. The statistical analyses show that short-term fractal scaling exponent alone is sufficient to distinguish between normal and CHF subjects. The receiver operating characteristic curve (ROC analysis confirms the robustness of this new approach and exhibits an average accuracy that exceeds 98.2%, average sensitivity of about 98.4%, positive predictivity of 98.00%, and average specificity of 98.00%.

  10. Associations between inadequate knee function detected by KOOS and prospective graft failure in an anterior cruciate ligament-reconstructed knee.

    Science.gov (United States)

    Granan, Lars-Petter; Baste, Valborg; Engebretsen, Lars; Inacio, Maria C S

    2015-04-01

    First, to evaluate whether the 2 year post-operative Knee injury and Osteoarthritis Outcome Score (KOOS) in primary anterior cruciate ligament reconstructions (ACLRs) was significantly different between patients that did not go on to have a subsequent revision after the 2 year post-operative control and the ones that did. Second, to test whether the "clinically failure" value of KOOS quality of life (QoL) < 44 was indicative of a clinically relevant difference in the risk of subsequent revision ACLR. ACLRs reported to the Norwegian Knee Ligament Registry between June 2004 and December 2009. 5,517 primary ACLRs with at least 2-year follow-up with KOOS QoL before revision surgery. There were clinically significant differences, adjusted and unadjusted, in both the KOOS Sport and Recreation and QoL subscales in patients with a later revision surgery compared to those that did not have a revision surgery. In adjusted models, the risk of later ACLR revision was 3.7 (95 % CI 2.2-6.0) higher in patients with a 2-year KOOS QoL < 44 compared to patients with a KOOS QoL ≥ 44. For every 10-point reduction in the KOOS QoL, a 33.6 % (95 % CI 21.2-47.5 %) higher risk for later ACLR revision was observed. This study reveals an association between inadequate knee function, as measured by KOOS, and a prospective ACL-reconstructed graft failure. Prognostic study (prospective cohort study), Level II.

  11. Detection of instrument or component failures in a nuclear plant by Luenberger observers

    International Nuclear Information System (INIS)

    Wilburn, N.P.; Colley, R.W.; Alexandro, F.J.; Clark, R.N.

    1985-01-01

    A diagnostic system, which will distinguish between instrument failures (flowmeters, etc.) and component failures (valves, filters, etc.) that show the same symptoms, has been developed for nuclear Plants using Luenberger observers. Luenberger observers are online computer based modules constructed following the technology of Clark [3]. A seventh order model of an FFTF subsystem was constructed using the Advanced Continuous Simulation Language (ACSL) and was used to show through simulation that Luenberger observers can be applied to nuclear systems

  12. Risk assessment of the emergency processes: Healthcare failure mode and effect analysis.

    Science.gov (United States)

    Taleghani, Yasamin Molavi; Rezaei, Fatemeh; Sheikhbardsiri, Hojat

    2016-01-01

    Ensuring about the patient's safety is the first vital step in improving the quality of care and the emergency ward is known as a high-risk area in treatment health care. The present study was conducted to evaluate the selected risk processes of emergency surgery department of a treatment-educational Qaem center in Mashhad by using analysis method of the conditions and failure effects in health care. In this study, in combination (qualitative action research and quantitative cross-sectional), failure modes and effects of 5 high-risk procedures of the emergency surgery department were identified and analyzed according to Healthcare Failure Mode and Effects Analysis (HFMEA). To classify the failure modes from the "nursing errors in clinical management model (NECM)", the classification of the effective causes of error from "Eindhoven model" and determination of the strategies to improve from the "theory of solving problem by an inventive method" were used. To analyze the quantitative data of descriptive statistics (total points) and to analyze the qualitative data, content analysis and agreement of comments of the members were used. In 5 selected processes by "voting method using rating", 23 steps, 61 sub-processes and 217 potential failure modes were identified by HFMEA. 25 (11.5%) failure modes as the high risk errors were detected and transferred to the decision tree. The most and the least failure modes were placed in the categories of care errors (54.7%) and knowledge and skill (9.5%), respectively. Also, 29.4% of preventive measures were in the category of human resource management strategy. "Revision and re-engineering of processes", "continuous monitoring of the works", "preparation and revision of operating procedures and policies", "developing the criteria for evaluating the performance of the personnel", "designing a suitable educational content for needs of employee", "training patients", "reducing the workload and power shortage", "improving team

  13. Active Fault Detection and Isolation for Hybrid Systems

    DEFF Research Database (Denmark)

    Gholami, Mehdi; Schiøler, Henrik; Bak, Thomas

    2009-01-01

    An algorithm for active fault detection and isolation is proposed. In order to observe the failure hidden due to the normal operation of the controllers or the systems, an optimization problem based on minimization of test signal is used. The optimization based method imposes the normal and faulty...... models predicted outputs such that their discrepancies are observable by passive fault diagnosis technique. Isolation of different faults is done by implementation a bank of Extended Kalman Filter (EKF) where the convergence criterion for EKF is confirmed by Genetic Algorithm (GA). The method is applied...

  14. Definitions of biochemical failure in prostate cancer following radiation therapy

    International Nuclear Information System (INIS)

    Taylor, Jeremy M.G.; Griffith, Kent A.; Sandler, Howard M.

    2001-01-01

    Purpose: The American Society for Therapeutic Radiology and Oncology (ASTRO) published a consensus panel definition of biochemical failure following radiation therapy for prostate cancer. In this paper, we develop a series of alternative definitions of biochemical failure. Using data from 688 patients, we evaluated the sensitivity and specificity of the various definitions, with respect to a defined 'clinically meaningful' outcome. Methods and Materials: The ASTRO definition of biochemical failure requires 3 consecutive rises in prostate-specific antigen (PSA). We considered several modifications to the standard definition: to require PSA rises of a certain magnitude, to consider 2 instead of 3 rises, to require the final PSA value to be greater than a fixed cutoff level, and to define biochemical failure based on the slope of PSA over 1, 1.5, or 2 years. A clinically meaningful failure is defined as local recurrence, distant metastases, initiation of unplanned hormonal therapy, unplanned radical prostatectomy, or a PSA>25 later than 6 months after radiation. Results: Requiring the final PSA in a series of consecutive rises to be larger than 1.5 ng/mL increased the specificity of biochemical failure. For a fixed specificity, defining biochemical failure based on 2 consecutive rises, or the slope over the last year, could increase the sensitivity by up to approximately 20%, compared to the ASTRO definition. Using a rule based on the slope over the previous year or 2 rises leads to a slightly earlier detection of biochemical failure than does the ASTRO definition. Even with the best rule, only approximately 20% of true failures are biochemically detected more than 1 year before the clinically meaningful event time. Conclusion: There is potential for improvement in the ASTRO consensus definition of biochemical failure. Further research is needed, in studies with long follow-up times, to evaluate the relationship between various definitions of biochemical failure and

  15. Power-limited low-thrust trajectory optimization with operation point detection

    Science.gov (United States)

    Chi, Zhemin; Li, Haiyang; Jiang, Fanghua; Li, Junfeng

    2018-06-01

    The power-limited solar electric propulsion system is considered more practical in mission design. An accurate mathematical model of the propulsion system, based on experimental data of the power generation system, is used in this paper. An indirect method is used to deal with the time-optimal and fuel-optimal control problems, in which the solar electric propulsion system is described using a finite number of operation points, which are characterized by different pairs of thruster input power. In order to guarantee the integral accuracy for the discrete power-limited problem, a power operation detection technique is embedded in the fourth-order Runge-Kutta algorithm with fixed step. Moreover, the logarithmic homotopy method and normalization technique are employed to overcome the difficulties caused by using indirect methods. Three numerical simulations with actual propulsion systems are given to substantiate the feasibility and efficiency of the proposed method.

  16. Approach of a failure analysis for the MYRRHA linac

    International Nuclear Information System (INIS)

    Carneiro, J.P.; Medeiros-Romao, L.; Salemne, R.; Vandeplassche, D.; Biarotte, J.L.; Bouly, F.; Uriot, D.

    2015-01-01

    The MYRRHA project currently under development at SCK-CEN (Mol, Belgium) is a subcritical research reactor that requires a 600 MeV proton accelerator as a driver. This linac is expected to produce a beam power of 1.5 MW onto a spallation target for the reactor to deliver a thermal power around 70 MW. Thermomechanical considerations of the spallation target set stringent requirements on the beam trip rate which should not exceed 40 trips/year for interruptions longer than three seconds. The 3 underlying principles in the design of the MYRRHA linac are elements redundancy (like the dual-injector), elements operation at de-rated values (like cavities operating at about 30% from their nominal operating points) and the fault tolerance concept, which allows the failure of a beamline component to be compensated by its neighbouring elements. Studies presented in this document show that in the event of a failure of the first cryo-module or the first quadrupole doublet the linac can resume nominal operation with a re-matched lattice. Since the fault tolerance procedure is expected to work more efficiently at higher energies (due to lower space charge effects) we can extrapolate from our studies that the MYRRHA linac is expected to operate with the failure of any cryo-module or quadrupole doublet in the main linac. A virtual accelerator-based control system is mandatory for the operation of the MYRRHA linac to ensure the very fast implementation (<3 seconds) of the fault tolerance procedure. The virtual accelerator uses a beam dynamics code (like TRACEWIN or TRACK) to compute the model of the real accelerator in operation and interacts with this later through the accelerator control command

  17. Ground failure in direct current systems of the Itaipu Hydroelectric Power Plant, Parana, Brazil. Impact in the operation; Falla a tierra en sistemas de corriente continua en la Central Hidroelectrica Itaipu, PR, Brasil. Impacto en la operacion

    Energy Technology Data Exchange (ETDEWEB)

    Soto Santacruz, Heriberto [Itaipu Binacional, Foz do Iguacu, PR (Brazil)]. E-mail: soto@itaipu.gov.py

    1998-07-01

    The objective of this work is to share with other companies the operation experience obtained by researching the direct current systems ground failure, in the Itaipu Hydroelectric Power Plant. During the research process electrical and/or electronic components can be damaged, and also human failures can occurred during the circuit connection and disconnection manoeuvres, necessary for the identification of the components causing the failures.

  18. NPP operator support in decision making - diagnostics of the operation failures using fuzzy logic

    International Nuclear Information System (INIS)

    Petruzela, I.

    2000-01-01

    In large complex systems such as nuclear power plants (NPP) and chemical industry plants, various subsystems fulfil the needs of process control and safety. Continued operation of these systems has both economic and safety implications. Electric utilities seek continuously to improve the operation of power generating stations. The improvement in the NPP Dukovany (4 x 440 MW) is related to the introduction of the plant to frequency control, meaning that the plant is operated not only in the base load operational mode but in the load follow mode as well. To achieve the improvement of plant operation, it was necessary to provide modifications to the plant control system, plant information system and diagnostics. This chapter deals with utilisation of artificial intelligence (AI) methods in implementation of these plant modifications. (orig.)

  19. Operational limitations of light water reactors relating to fuel performance

    International Nuclear Information System (INIS)

    Cheng, H.S.

    1976-07-01

    General aspects of fuel performance for typical Boiling and Pressurized Water Reactors are presented. Emphasis is placed on fuel failures in order to make clear important operational limitations. A discussion of fuel element designs is first given to provide the background information for the subsequent discussion of several fuel failure modes that have been identified. Fuel failure experiences through December 31, 1974, are summarized. The operational limitations that are required to mitigate the effects of fuel failures are discussed

  20. A Near-Term Concept for Trajectory Based Operations with Air/Ground Data Link Communication

    Science.gov (United States)

    McNally, David; Mueller, Eric; Thipphavong, David; Paielli, Russell; Cheng, Jinn-Hwei; Lee, Chuhan; Sahlman, Scott; Walton, Joe

    2010-01-01

    An operating concept and required system components for trajectory-based operations with air/ground data link for today's en route and transition airspace is proposed. Controllers are fully responsible for separation as they are today, and no new aircraft equipage is required. Trajectory automation computes integrated solutions to problems like metering, weather avoidance, traffic conflicts and the desire to find and fly more time/fuel efficient flight trajectories. A common ground-based system supports all levels of aircraft equipage and performance including those equipped and not equipped for data link. User interface functions for the radar controller's display make trajectory-based clearance advisories easy to visualize, modify if necessary, and implement. Laboratory simulations (without human operators) were conducted to test integrated operation of selected system components with uncertainty modeling. Results are based on 102 hours of Fort Worth Center traffic recordings involving over 37,000 individual flights. The presence of uncertainty had a marginal effect (5%) on minimum-delay conflict resolution performance, and windfavorable routes had no effect on detection and resolution metrics. Flight plan amendments and clearances were substantially reduced compared to today s operations. Top-of-descent prediction errors are the largest cause of failure indicating that better descent predictions are needed to reliably achieve fuel-efficient descent profiles in medium to heavy traffic. Improved conflict detections for climbing flights could enable substantially more continuous climbs to cruise altitude. Unlike today s Conflict Alert, tactical automation must alert when an altitude amendment is entered, but before the aircraft starts the maneuver. In every other failure case tactical automation prevented losses of separation. A real-time prototype trajectory trajectory-automation system is running now and could be made ready for operational testing at an en route