WorldWideScience

Sample records for factors including water

  1. Determination of point isotropic buildup factors of gamma rays including incoherent and coherent scattering for aluminum, iron, lead, and water by discrete ordinates method

    International Nuclear Information System (INIS)

    Kitsos, S.; Assad, A.; Diop, C.M.; Nimal, J.C.

    1994-01-01

    Exposure and energy absorption buildup factors for aluminum, iron, lead, and water are calculated by the SNID discrete ordinates code for an isotropic point source in a homogeneous medium. The calculation of the buildup factors takes into account the effects of both bound-electron Compton (incoherent) and coherent (Rayleigh) scattering. A comparison with buildup factors from the literature shows that these two effects greatly increase the buildup factors for energies below a few hundred kilo-electron-volts, and thus the new results are improved relative to the experiment. This greater accuracy is due to the increase in the linear attenuation coefficient, which leads to the calculation of the buildup factors for a mean free path with a smaller shield thickness. On the other hand, for the same shield thickness, exposure increases when only incoherent scattering is included and decreases when only coherent scattering is included, so that the exposure finally decreases when both effects are included. Great care must also be taken when checking the approximations for gamma-ray deep-penetration transport calculations, as well as for the cross-section treatment and origin

  2. Safety of Bottled Water Beverages Including Flavored Water and Nutrient-Added Water Beverages

    Science.gov (United States)

    ... Food Resources for You Consumers FDA Regulates the Safety of Bottled Water Beverages Including Flavored Water and Nutrient-Added Water Beverages ... addition, the flavorings and nutrients added to these beverages must comply with all applicable FDA safety requirements and they must be identified in the ...

  3. Towards ligand docking including explicit interface water molecules.

    Directory of Open Access Journals (Sweden)

    Gordon Lemmon

    Full Text Available Small molecule docking predicts the interaction of a small molecule ligand with a protein at atomic-detail accuracy including position and conformation the ligand but also conformational changes of the protein upon ligand binding. While successful in the majority of cases, docking algorithms including RosettaLigand fail in some cases to predict the correct protein/ligand complex structure. In this study we show that simultaneous docking of explicit interface water molecules greatly improves Rosetta's ability to distinguish correct from incorrect ligand poses. This result holds true for both protein-centric water docking wherein waters are located relative to the protein binding site and ligand-centric water docking wherein waters move with the ligand during docking. Protein-centric docking is used to model 99 HIV-1 protease/protease inhibitor structures. We find protease inhibitor placement improving at a ratio of 9:1 when one critical interface water molecule is included in the docking simulation. Ligand-centric docking is applied to 341 structures from the CSAR benchmark of diverse protein/ligand complexes [1]. Across this diverse dataset we see up to 56% recovery of failed docking studies, when waters are included in the docking simulation.

  4. Neutron disadvantage factors in heavy water and light water reactors

    International Nuclear Information System (INIS)

    Pop-Jordanov, J.

    1966-01-01

    A number od heavy water and light water reactor cells are analyzed in this paper by applying analytical methods of neutron thermalization. Calculations done according to the one-group Amouyal-Benoist method are included in addition. Computer codes for ZUSE Z-23 computer were written by applying both methods. The obtained results of disadvantage factors are then compared to results obtained by one-group P 3 approximation and by multigroup K7-THERMOS code [sr

  5. Identification and assessment of potential water quality impact factors for drinking-water reservoirs.

    Science.gov (United States)

    Gu, Qing; Deng, Jinsong; Wang, Ke; Lin, Yi; Li, Jun; Gan, Muye; Ma, Ligang; Hong, Yang

    2014-06-10

    Various reservoirs have been serving as the most important drinking water sources in Zhejiang Province, China, due to the uneven distribution of precipitation and severe river pollution. Unfortunately, rapid urbanization and industrialization have been continuously challenging the water quality of the drinking-water reservoirs. The identification and assessment of potential impacts is indispensable in water resource management and protection. This study investigates the drinking water reservoirs in Zhejiang Province to better understand the potential impact on water quality. Altogether seventy-three typical drinking reservoirs in Zhejiang Province encompassing various water storage levels were selected and evaluated. Using fifty-two reservoirs as training samples, the classification and regression tree (CART) method and sixteen comprehensive variables, including six sub-sets (land use, population, socio-economy, geographical features, inherent characteristics, and climate), were adopted to establish a decision-making model for identifying and assessing their potential impacts on drinking-water quality. The water quality class of the remaining twenty-one reservoirs was then predicted and tested based on the decision-making model, resulting in a water quality class attribution accuracy of 81.0%. Based on the decision rules and quantitative importance of the independent variables, industrial emissions was identified as the most important factor influencing the water quality of reservoirs; land use and human habitation also had a substantial impact on water quality. The results of this study provide insights into the factors impacting the water quality of reservoirs as well as basic information for protecting reservoir water resources.

  6. Levels of major and trace elements, including rare earth elements, and ²³⁸U in Croatian tap waters.

    Science.gov (United States)

    Fiket, Željka; Rožmarić, Martina; Krmpotić, Matea; Benedik, Ljudmila

    2015-05-01

    Concentrations of 46 elements, including major, trace, and rare earth elements, and (238)U in Croatian tap waters were investigated. Selected sampling locations include tap waters from various hydrogeological regions, i.e., different types of aquifers, providing insight into the range of concentrations of studied elements and (238)U activity concentrations in Croatian tap waters. Obtained concentrations were compared with the Croatian maximum contaminant levels for trace elements in water intended for human consumption, as well as WHO and EPA drinking water standards. Concentrations in all analyzed tap waters were found in accordance with Croatian regulations, except tap water from Šibenik in which manganese in concentration above maximum permissible concentration (MPC) was measured. Furthermore, in tap water from Osijek, levels of arsenic exceeded the WHO guidelines and EPA regulations. In general, investigated tap waters were found to vary considerably in concentrations of studied elements, including (238)U activity concentrations. Causes of variability were further explored using statistical methods. Composition of studied tap waters was found to be predominately influenced by hydrogeological characteristics of the aquifer, at regional and local level, the existing redox conditions, and the household plumbing system. Rare earth element data, including abundances and fractionation patterns, complemented the characterization and facilitated the interpretation of factors affecting the composition of the analyzed tap waters.

  7. Prototype solar heating and cooling systems including potable hot water

    Science.gov (United States)

    1978-01-01

    Progress is reviewed in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water. The system consisted of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

  8. Urban water consumption and its influencing factors in China

    NARCIS (Netherlands)

    Fan, Liangxin; Gai, Lingtong; Tong, Yan; Li, Ruihua

    2017-01-01

    Factors that affect water consumption should be identified to develop effective public policies. However, factors influencing domestic water consumption in cities in China, particularly on a national scale, are unclear. In this study, urban water consumption and its influencing factors in 286

  9. Operational water consumption and withdrawal factors for electricity generating technologies: a review of existing literature

    International Nuclear Information System (INIS)

    Macknick, J; Newmark, R; Heath, G; Hallett, K C

    2012-01-01

    This report provides estimates of operational water withdrawal and water consumption factors for electricity generating technologies in the United States. Estimates of water factors were collected from published primary literature and were not modified except for unit conversions. The water factors presented may be useful in modeling and policy analyses where reliable power plant level data are not available. Major findings of the report include: water withdrawal and consumption factors vary greatly across and within fuel technologies, and water factors show greater agreement when organized according to cooling technologies as opposed to fuel technologies; a transition to a less carbon-intensive electricity sector could result in either an increase or a decrease in water use, depending on the choice of technologies and cooling systems employed; concentrating solar power technologies and coal facilities with carbon capture and sequestration capabilities have the highest water consumption values when using a recirculating cooling system; and non-thermal renewables, such as photovoltaics and wind, have the lowest water consumption factors. Improved power plant data and further studies into the water requirements of energy technologies in different climatic regions would facilitate greater resolution in analyses of water impacts of future energy and economic scenarios. This report provides the foundation for conducting water use impact assessments of the power sector while also identifying gaps in data that could guide future research. (letter)

  10. High water-stressed population estimated by world water resources assessment including human activities under SRES scenarios

    Science.gov (United States)

    Kiguchi, M.; Shen, Y.; Kanae, S.; Oki, T.

    2009-04-01

    In an argument of the reduction and the adaptation for the climate change, the evaluation of the influence by the climate change is important. When we argue in adaptation plan from a damage scale and balance with the cost, it is particularly important. Parry et al (2001) evaluated the risks in shortage of water, malaria, food, the risk of the coast flood by temperature function and clarified the level of critical climate change. According to their evaluation, the population to be affected by the shortage of water suddenly increases in the range where temperature increases from 1.5 to 2.0 degree in 2080s. They showed how much we need to reduce emissions in order to draw-down significantly the number at risk. This evaluation of critical climate change threats and targets of water shortage did not include the water withdrawal divided by water availability. Shen et al (2008a) estimated the water withdrawal of projection of future world water resources according to socio-economic driving factors predicted for scenarios A1b, A2, B1, and B2 of the Special Report on Emission Scenarios (SRES). However, these results were in function of not temperature but time. The assessment of the highly water-stressed population considered the socioeconomic development is necessary for a function of the temperature. Because of it is easy to understand to need to reduce emission. We present a multi-GCM analysis of the global and regional populations lived in highly water-stressed basin for a function of the temperature using the socioeconomic data and the outputs of GCMs. In scenario A2, the population increases gradually with warming. On the other hand, the future projection population in scenario A1b and B1 increase gradually until the temperature anomaly exceeds around from +1 to +1.5 degree. After that the population is almost constant. From Shen et al (2008b), we evaluated the HWSP and its ratio in the world with temperature function for scenarios A1B, A2, and B1 by the index of W

  11. Engineering factors influencing Corbicula fouling in nuclear-service water systems

    International Nuclear Information System (INIS)

    Henager, C.H.; Johnson, K.I.; Page, T.L.

    1983-06-01

    Corbicula fouling is a continuing problem in nuclear-service water systems. More knowledge of biological and engineering factors is needed to develop effective detection and control methods. A data base on Corbicula fouling was compiled from nuclear and non-nuclear power stations and industries using raw water. This data base was used in an analysis to identify systems and components which are conducive to fouling by Corbicula. Bounds on several engineering parameters such as velocity and temperature which support Corbicula growth are given. Service water systems found in BWR and PWR reactors are listed and those that show fouling are identified. Possible safety implications of Corbicula fouling are discussed for specific service water systems. Several effective control methods in current use include backflushing with heated water, centrifugal strainers, and continuous chlorination during spawning seasons

  12. Factors Responsible for Domestic Water Contamination | Idika ...

    African Journals Online (AJOL)

    This study was therefore designed to identify the factors that influenced domestic water contamination in our rural communities and recommend some intervention measures that can reduce this high morbidity and mortality due to diarrhoeal diseases in Nigeria. Water samples from the water sources serving six rural ...

  13. Fate factors and emission flux estimates for emerging contaminants in surface waters

    Directory of Open Access Journals (Sweden)

    Hoa T. Trinh

    2016-01-01

    Full Text Available Pharmaceuticals, personal care products, hormones, and wastewater products are emerging environmental concerns for manifold reasons, including the potential of some compounds found in these products for endocrine disruption at a very low chronic exposure level. The environmental occurrences and sources of these contaminants in the water, soil, sediment and biota in European nations and the United States are well documented. This work reports a screening-level emission and fate assessment of thirty compounds, listed in the National Reconnaissance of the United States Geological Survey (USGS, 1999–2000 as the most frequently detected organic wastewater contaminants in U.S. streams and rivers. Estimations of the surface water fate factors were based on Level II and Level III multimedia fugacity models for a 1000 km2 model environment, the size of a typical county in the eastern United States. The compounds are categorized into three groups based upon the sensitivity of their predicted surface water fate factors to uncertainties in their physicochemical property values and the landscape parameters. The environmental fate factors, mass distributions, and loss pathways of all of the compounds are strongly affected by their assumed modes of entry into the environment. It is observed that for thirteen of the thirty organic wastewater contaminants most commonly detected in surface waters, conventional treatment strategies may be ineffective for their removal from wastewater effluents. The surface water fate factors predicted by the fugacity models were used in conjunction with the surface water concentrations measured in the USGS reconnaissance to obtain emission flux estimates for the compounds into U.S. streams and rivers. These include estimated fluxes of 6.8 × 10−5 to 0.30 kg/h km2 for the biomarker coprostanol; 1.7 × 10−5 to 6.5 × 10−5 kg/h km2 for the insect repellent N,N-diethyltoluamide; and 4.3 × 10−6 to 3.1 × 10−5 kg/h km2 for

  14. Factors affecting sustainability of rural water schemes in Swaziland

    Science.gov (United States)

    Peter, Graciana; Nkambule, Sizwe E.

    The Millennium Development Goal (MDG) target to reduce the proportion of people without sustainable access to safe drinking water by the year 2015 has been met as of 2010, but huge disparities exist. Some regions, particularly Sub-Saharan Africa are lagging behind it is also in this region where up to 30% of the rural schemes are not functional at any given time. There is need for more studies on factors affecting sustainability and necessary measures which when implemented will improve the sustainability of rural water schemes. The main objective of this study was to assess the main factors affecting the sustainability of rural water schemes in Swaziland using a Multi-Criteria Analysis Approach. The main factors considered were: financial, social, technical, environmental and institutional. The study was done in Lubombo region. Fifteen functional water schemes in 11 communities were studied. Data was collected using questionnaires, checklist and focused group discussion guide. A total of 174 heads of households were interviewed. Statistical Package for Social Sciences (SPSS) was used to analyse the data and to calculate sustainability scores for water schemes. SPSS was also used to classify sustainability scores according to sustainability categories: sustainable, partially sustainable and non-sustainable. The averages of the ratings for the different sub-factors studied and the results on the sustainability scores for the sustainable, partially sustainable and non-sustainable schemes were then computed and compared to establish the main factors influencing sustainability of the water schemes. The results indicated technical and social factors as most critical while financial and institutional, although important, played a lesser role. Factors which contributed to the sustainability of water schemes were: functionality; design flow; water fetching time; ability to meet additional demand; use by population; equity; participation in decision making on operation and

  15. Building new WDM regulations for the Namibian tourism sector on factors influencing current water-management practices at the enterprise level

    Science.gov (United States)

    Schachtschneider, Klaudia

    Namibia's aridity is forcing its water sector to resort to new water resource management approaches, including water demand management (WDM). Such a change in management approach is facilitated through the country's opportunity at independence to rewrite and adapt its old policies, including those for water and tourism. Legal support for WDM through the Water Act and other sector-specific Acts is crucial to plan the practical implementation of WDM throughout the different water use sectors of Namibia. In order to be able to put the policy into practice, it is imperative to understand which factors motivate people to adopt WDM initiatives. Within the Namibian tourism industry three main factors have been identified which influence the water-management approaches at tourist facilities. This paper discusses how the water and tourism decision makers can consider these factors when developing new regulations to introduce WDM in the tourism sector.

  16. 78 FR 56695 - Proposed Listing of Additional Waters To Be Included on Indiana's 2010 List of Impaired Waters...

    Science.gov (United States)

    2013-09-13

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9900-95--Region 5] Proposed Listing of Additional Waters To Be Included on Indiana's 2010 List of Impaired Waters Under the Clean Water Act AGENCY: Environmental Protection Agency (EPA). ACTION: Reopening of comment period. SUMMARY: EPA is reopening the comment period...

  17. Development of fauna of water beetles (Coleoptera in waters bodies of a river valley – habitat factors, landscape and geomorphology

    Directory of Open Access Journals (Sweden)

    Pakulnicka Joanna

    2016-01-01

    Full Text Available The goal of the study was to identify the beetle fauna of a small lowland river valley against its spatial arrangement and the directions of beetle migrations between habitats, as well as to determine which environmental factors affect the characteristics of water beetle populations in a river valley's lentic water bodies. The field studies were carried out in various types of water bodies. 112 species of beetles with various ecological characteristics were identified. It was demonstrated that the diversity of water bodies in the valley is conducive to high local species richness. At the same time, the observed high degree of faunistic individualism may be regarded as a sign of poor symmetry in the directions of fauna propagation, particularly that of stagnobionts. The authors argue that high individualism is the consequence of poor hydrological contact between the water bodies due to topography and rare instances of high tide in the river, which, in turn, is the reason for active overflights remaining the main mean of migration between those water bodies. The factors restricting migration of fauna between the water bodies include certain landscape characteristics of the catchment which form topographical obstacles, mainly numerous and dense forest areas. The character of fauna in the respective types of water bodies is affected also by internal environmental factors, particularly the degree to which they are overgrown with macrophytes, type of bottom, type of mineral and organic matter as well as physical parameters of water, such as saturation, pH, temperature and biological oxygen demand.

  18. A new approach on anti-vortex devices at water intakes including a submerged water jet

    Science.gov (United States)

    Tahershamsi, Ahmad; Rahimzadeh, Hassan; Monshizadeh, Morteza; Sarkardeh, Hamed

    2018-04-01

    A new approach on anti-vortex methods as hydraulic-based anti-vortex was investigated experimentally in the present study. In the investigated method, a submerged water jet is used as the anti-vortex mechanism. The added jet acts as a source of external momentum. This leads to change the intake-induced hydrodynamic pattern in the near-field of the intake structure, which can prevent formation of undesirable intake vortices. The experiments were carried out on a horizontal pipe intake. By performing 570 test cases in two different categories, including the inclined jet with respect to the axis of the intake, and the inclined jet with respect to the water surface, the effects of the jet inclination angle on the anti-vortex performance were investigated. It was found that the inclined jet with respect to the water surface is the best alternative to consider as the water jet injection pattern. Results showed that using the inclined jet with respect to the water surface can simply reduce the amounts of the expected water jet momentum more than 50% compared to that of the similar condition of the horizontal injection pattern. Moreover, it was concluded that the intake critical submergence can easily be minimized using the inclined jet with respect to the water surface.

  19. Energy-Water Nexus Relevant to Baseload Electricity Source Including Mini/Micro Hydropower Generation

    Science.gov (United States)

    Fujii, M.; Tanabe, S.; Yamada, M.

    2014-12-01

    Water, food and energy is three sacred treasures that are necessary for human beings. However, recent factors such as population growth and rapid increase in energy consumption have generated conflicting cases between water and energy. For example, there exist conflicts caused by enhanced energy use, such as between hydropower generation and riverine ecosystems and service water, between shale gas and ground water, between geothermal and hot spring water. This study aims to provide quantitative guidelines necessary for capacity building among various stakeholders to minimize water-energy conflicts in enhancing energy use. Among various kinds of renewable energy sources, we target baseload sources, especially focusing on renewable energy of which installation is required socially not only to reduce CO2 and other greenhouse gas emissions but to stimulate local economy. Such renewable energy sources include micro/mini hydropower and geothermal. Three municipalities in Japan, Beppu City, Obama City and Otsuchi Town are selected as primary sites of this study. Based on the calculated potential supply and demand of micro/mini hydropower generation in Beppu City, for example, we estimate the electricity of tens through hundreds of households is covered by installing new micro/mini hydropower generation plants along each river. However, the result is based on the existing infrastructures such as roads and electric lines. This means that more potentials are expected if the local society chooses options that enhance the infrastructures to increase micro/mini hydropower generation plants. In addition, further capacity building in the local society is necessary. In Japan, for example, regulations by the river law and irrigation right restrict new entry by actors to the river. Possible influences to riverine ecosystems in installing new micro/mini hydropower generation plants should also be well taken into account. Deregulation of the existing laws relevant to rivers and

  20. Assessing risks for integrated water resource management: coping with uncertainty and the human factor

    Directory of Open Access Journals (Sweden)

    M. J. Polo

    2014-09-01

    Full Text Available Risk assessment for water resource planning must deal with the uncertainty associated with excess/scarcity situations and their costs. The projected actions for increasing water security usually involve an indirect "call-effect": the territory occupation/water use is increased following the achieved protection. In this work, flood and water demand in a mountainous semi-arid watershed in southern Spain are assessed by means of the stochastic simulation of extremes, when this human factor is/is not considered. The results show how not including this call-effect induced an underestimation of flood risk after protecting the floodplain of between 35 and 78 % in a 35-year planning horizon. Similarly, the pursued water availability of a new reservoir resulted in a 10-year scarcity risk increase up to 38 % when the trend of expanding the irrigated area was included in the simulations. These results highlight the need for including this interaction in the decision-making assessment.

  1. QMRAcatch: Microbial Quality Simulation of Water Resources including Infection Risk Assessment.

    Science.gov (United States)

    Schijven, Jack; Derx, Julia; de Roda Husman, Ana Maria; Blaschke, Alfred Paul; Farnleitner, Andreas H

    2015-09-01

    Given the complex hydrologic dynamics of water catchments and conflicts between nature protection and public water supply, models may help to understand catchment dynamics and evaluate contamination scenarios and may support best environmental practices and water safety management. A catchment model can be an educative tool for investigating water quality and for communication between parties with different interests in the catchment. This article introduces an interactive computational tool, QMRAcatch, that was developed to simulate concentrations in water resources of , a human-associated microbial source tracking (MST) marker, enterovirus, norovirus, , and as target microorganisms and viruses (TMVs). The model domain encompasses a main river with wastewater discharges and a floodplain with a floodplain river. Diffuse agricultural sources of TMVs that discharge into the main river are not included in this stage of development. The floodplain river is fed by the main river and may flood the plain. Discharged TMVs in the river are subject to dilution and temperature-dependent degradation. River travel times are calculated using the Manning-Gauckler-Strickler formula. Fecal deposits from wildlife, birds, and visitors in the floodplain are resuspended in flood water, runoff to the floodplain river, or infiltrate groundwater. Fecal indicator and MST marker data facilitate calibration. Infection risks from exposure to the pathogenic TMVs by swimming or drinking water consumption are calculated, and the required pathogen removal by treatment to meet a health-based quality target can be determined. Applicability of QMRAcatch is demonstrated by calibrating the tool for a study site at the River Danube near Vienna, Austria, using field TMV data, including a sensitivity analysis and evaluation of the model outcomes. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. Factors that may compromise bulk water distribution reliability

    OpenAIRE

    2012-01-01

    D.Ing. This thesis considers water supply and divides the water supply environment into three categories; the macro water supply environment, the water supply scheme and the consumers. Each of the categories is briefly explored in terms of the factors that may influence it. Subsequently, some of the unique features of a bulk water distribution system are dealt with, as well as different approaches related to bulk water distribution system design and assessment. One of these approaches, the...

  3. Studies on kinetics of water quality factors to establish water transparency model in Neijiang River, China.

    Science.gov (United States)

    Li, Ronghui; Pan, Wei; Guo, Jinchuan; Pang, Yong; Wu, Jianqiang; Li, Yiping; Pan, Baozhu; Ji, Yong; Ding, Ling

    2014-05-01

    The basis for submerged plant restoration in surface water is to research the complicated dynamic mechanism of water transparency. In this paper, through the impact factor analysis of water transparency, the suspended sediment, dissolved organic matter, algae were determined as three main impactfactors for water transparency of Neijiang River in Eastern China. And the multiple regression equation of water transparency and sediment concentration, permanganate index, chlorophyll-a concentration was developed. Considering the complicated transport and transformation of suspended sediment, dissolved organic matter and algae, numerical model of them were developed respectively for simulating the dynamic process. Water transparency numerical model was finally developed by coupling the sediment, water quality, and algae model. These results showed that suspended sediment was a key factor influencing water transparency of Neijiang River, the influence of water quality indicated by chemical oxygen demand and algal concentration indicated by chlorophyll a were indeterminate when their concentrations were lower, the influence was more obvious when high concentrations are available, such three factors showed direct influence on water transparency.

  4. Assessing the significance of climate and community factors on urban water demand

    OpenAIRE

    Md Mahmudul Haque; Prasanna Egodawatta; Ataur Rahman; Ashantha Goonetilleke

    2015-01-01

    Ensuring adequate water supply to urban areas is a challenging task due to factors such as rapid urban growth, increasing water demand and climate change. In developing a sustainable water supply system, it is important to identify the dominant water demand factors for any given water supply scheme. This paper applies principal components analysis to identify the factors that dominate residential water demand using the Blue Mountains Water Supply System in Australia as a case study. The resul...

  5. Risk Factors Associated with the Choice to Drink Bottled Water and Tap Water in Rural Saskatchewan

    Directory of Open Access Journals (Sweden)

    Lianne McLeod

    2014-01-01

    Full Text Available A cross-sectional study investigated risk factors associated with choices to drink bottled water and tap water in rural Saskatchewan. Of 7,500 anonymous postal questionnaires mailed out, 2,065 responses were analyzed using generalized linear mixed models. Those who reported a water advisory (p < 0.001 or living in the area for £10 years (p = 0.01 were more likely to choose bottled water. Those who reported tap water was not safe to drink were more likely to choose bottled water, an effect greater for those who had no aesthetic complaints (p ≤ 0.001, while those with aesthetic complaints were more likely to choose bottled water if they believed the water was safe (p < 0.001. Respondents who treated their water and did not use a community supply were more likely to choose bottled water (p < 0.001, while those who did not treat their water were more likely to choose bottled water regardless of whether a community supply was used (p < 0.001. A similar pattern of risk factors was associated with a decreased likelihood of consuming tap water daily; however, the use of a community water supply was not significant. Understanding the factors involved in drinking water choices could inform public health education efforts regarding water management in rural areas.

  6. Surface Water Quality Assessment and Prioritize the Factors Pollute This Water Using Topsis Fuzzy Hierarchical Analysis

    Directory of Open Access Journals (Sweden)

    Mehdi Komasi

    2017-03-01

    Full Text Available Background & Objective: Nowadays, according to growth of industry and increasing population, water resources are seriousely shortened. This lack of water resources will require special management to be considered in industry and agriculture. Among the various sources of water, surface waters are more susceptible to infection. The most important of these sources of pollution are industrial pollution, detergent, pesticides, radioactive materials, heat and salt concentration.  Materials & methods: In this article, at first the importance of each pollutant will be evaluated base on the effects and its results and then quality evaluation of surface water will be studied. In order to assess the relative importance of these pollutants primarily using TOPSIS software, prioritize these factors as one of the hierarchical analysis and then is modeled with decision tree method using Weka software, the importance of each factor is evaluated and if it does not meet the minimal importance of the decision tree will be removed. Results: The results obtained from the Topsis fuzzy analysis indicate that surface water and groundwater are exposed to pollution about 74% and 26% respectively among the six pollutants examined in this study. In addition, results obtaned from the hierarchical tree in software Weka has shown that the heat factor, soluble salts and industrial pollutants give impac factor or purity about 0.1338, 0.0523 and 1.2694 respectively. Conclusion: Surface water is at greater risk of being polluted compared with groundwater. The heat factor and low concentration of dissolved salts have the low impact and industrial pollutants are considered as the most influential factors in surface water pollution.

  7. Parallel factor analysis PARAFAC of process affected water

    Energy Technology Data Exchange (ETDEWEB)

    Ewanchuk, A.M.; Ulrich, A.C.; Sego, D. [Alberta Univ., Edmonton, AB (Canada). Dept. of Civil and Environmental Engineering; Alostaz, M. [Thurber Engineering Ltd., Calgary, AB (Canada)

    2010-07-01

    A parallel factor analysis (PARAFAC) of oil sands process-affected water was presented. Naphthenic acids (NA) are traditionally described as monobasic carboxylic acids. Research has indicated that oil sands NA do not fit classical definitions of NA. Oil sands organic acids have toxic and corrosive properties. When analyzed by fluorescence technology, oil sands process-affected water displays a characteristic peak at 290 nm excitation and approximately 346 nm emission. In this study, a parallel factor analysis (PARAFAC) was used to decompose process-affected water multi-way data into components representing analytes, chemical compounds, and groups of compounds. Water samples from various oil sands operations were analyzed in order to obtain EEMs. The EEMs were then arranged into a large matrix in decreasing process-affected water content for PARAFAC. Data were divided into 5 components. A comparison with commercially prepared NA samples suggested that oil sands NA is fundamentally different. Further research is needed to determine what each of the 5 components represent. tabs., figs.

  8. Biological stability of drinking water: controlling factors, methods and challenges

    Directory of Open Access Journals (Sweden)

    Emmanuelle ePrest

    2016-02-01

    Full Text Available Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g. development of opportunistic pathogens, aesthetic (e.g. deterioration of taste, odour, colour or operational (e.g. fouling or biocorrosion of pipes problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors such as (i type and concentration of available organic and inorganic nutrients, (ii type and concentration of residual disinfectant, (iii presence of predators such as protozoa and invertebrates, (iv environmental conditions such as water temperature, and (v spatial location of microorganisms (bulk water, sediment or biofilm. Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i existing knowledge on biological stability controlling factors and (ii how these factors are affected by drinking water production and distribution conditions. In addition, (iii the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discuss how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order to

  9. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    Science.gov (United States)

    Prest, Emmanuelle I.; Hammes, Frederik; van Loosdrecht, Mark C. M.; Vrouwenvelder, Johannes S.

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  10. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    KAUST Repository

    Prest, Emmanuelle I.

    2016-02-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  11. Identifying factors affecting optimal management of agricultural water

    Directory of Open Access Journals (Sweden)

    Masoud Samian

    2015-01-01

    In addition to quantitative methodology such as descriptive statistics and factor analysis a qualitative methodology was employed for dynamic simulation among variables through Vensim software. In this study, the factor analysis technique was used through the Kaiser-Meyer-Olkin (KMO and Bartlett tests. From the results, four key elements were identified as factors affecting the optimal management of agricultural water in Hamedan area. These factors were institutional and legal factors, technical and knowledge factors, economic factors and social factors.

  12. Risk Factors for Breast Cancer, Including Occupational Exposures

    Directory of Open Access Journals (Sweden)

    Elisabete Weiderpass

    2011-03-01

    Full Text Available The knowledge on the etiology of breast cancer has advanced substantially in recent years, and several etiological factors are now firmly established. However, very few new discoveries have been made in relation to occupational risk factors. The International Agency for Research on Cancer has evaluated over 900 different exposures or agents to-date to determine whether they are carcinogenic to humans. These evaluations are published as a series of Monographs (www.iarc.fr. For breast cancer the following substances have been classified as “carcinogenic to humans” (Group 1: alcoholic beverages, exposure to diethylstilbestrol, estrogen-progestogen contraceptives, estrogen-progestogen hormone replacement therapy and exposure to X-radiation and gamma-radiation (in special populations such as atomic bomb survivors, medical patients, and in-utero exposure. Ethylene oxide is also classified as a Group 1 carcinogen, although the evidence for carcinogenicity in epidemiologic studies, and specifically for the human breast, is limited. The classification “probably carcinogenic to humans” (Group 2A includes estrogen hormone replacement therapy, tobacco smoking, and shift work involving circadian disruption, including work as a flight attendant. If the association between shift work and breast cancer, the most common female cancer, is confirmed, shift work could become the leading cause of occupational cancer in women.

  13. Perinatal risk factors including malformation

    International Nuclear Information System (INIS)

    Brachner, A.; Grosche, B.

    1991-10-01

    The study gives a survey of the factors most frequently mentioned in the literature as factors likely to adversely affect a pregnancy. One essential aspect is the discussion of those factors that can be counted among the causes of malformations, as among others, prenatal radiation exposure. The study prepared within the framework of the research project 'Radiobiological environmental monitoring in Bavaria' is intended to serve as a basis for a retrospective and prospective evaluation of infant mortality, perinatal conditions and occurrence of malformations in Bavaria, with the principal idea of drawing up an environment - related health survey. The study therefore, in addition to ionizing radiation also takes into account other detectable risks within the ecologic context, as e.g. industrial installations, refuse incineration plants or waste dumps, or urbanity. (orig./MG) [de

  14. Neutron kerma factors, and water equivalence of some tissue substitutes

    International Nuclear Information System (INIS)

    Singh, V. P.; Badiger, N. M.; Vega C, H. R.

    2014-08-01

    The kerma factors and kerma relative to air and water of 24 compounds used as tissue substitutes were calculated for neutron energy from 2.53 x 10 -8 up to 29 MeV. The kerma ratio of the tissue substitutes relative to air and water were calculated by the ratio of kerma factors of the tissue substitute to air and water respectively. The water equivalence of the selected tissue substitutes was observed above neutron energies 100 eV. Kerma ratio relative to the air for Poly-vinylidene fluoride and Teflon are found to be nearest to unity in very low energy (up to 1 eV) and above 63 eV respectively. It was found that the natural rubber as a water equivalent tissue substitute compound. The results of the kerma factors in our investigation shows a very good agreement with those published in ICRU-44. We found that at higher neutron energies, the kerma factors and kerma ratios of the selected tissue substitute compounds are approximately same, but differences are large for energies below 100 eV. (Author)

  15. On the use of risk-informed regulation including organizational factors

    International Nuclear Information System (INIS)

    Gibelli, S.M.O.; Alvarenga, M.A.B.

    1998-01-01

    Risk-Informed Regulation (RIR) can be applied by using Probabilistic Safety Assessment (PSA) as a basic tool. Traditionally, PSA methodology encompasses the calculation of failure probabilities of Structures, Systems and Components (SSCs) and direct associated human errors. However, there are indirect causes related to human failures, associated with Organizational Factors, which are normally not included in fault trees, that may influence plant risk evaluation. This paper discusses on possible applications of RIR and on Organizational Factors. It also presents a classification of Angra-1 NPP unresolved issues, aiming a future inclusion of these factors into a PSA calculation. (author)

  16. Influence factors analysis of water environmental quality of main rivers in Tianjin

    Science.gov (United States)

    Li, Ran; Bao, Jingling; Zou, Di; Shi, Fang

    2018-01-01

    According to the evaluation results of the water environment quality of main rivers in Tianjin in 1986-2015, this paper analyzed the current situation of water environmental quality of main rivers in Tianjin retrospectively, established the index system and multiple factors analysis through selecting factors influencing the water environmental quality of main rivers from the economy, industry and nature aspects with the combination method of principal component analysis and linear regression. The results showed that water consumption, sewage discharge and water resources were the main factors influencing the pollution of main rivers. Therefore, optimizing the utilization of water resources, improving utilization efficiency and reducing effluent discharge are important measures to reduce the pollution of surface water environment.

  17. Exploration of an Optimal Policy for Water Resources Management Including the Introduction of Advanced Sewage Treatment Technologies in Zaozhuang City, China

    Directory of Open Access Journals (Sweden)

    Gengyu He

    2016-12-01

    Full Text Available Water shortage and water pollution are important factors restricting sustainable social and economic development. As a typical coal resource-exhausted city and a node city of the South-to-North Water Transfer East Route Project in China, Zaozhuang City’s water resources management faces multiple constraints such as transformation of economic development, restriction of groundwater exploitation, and improvement of water environment. In this paper, we develop a linear optimization model by input–output analysis to study water resources management with the introduction of three advanced sewage treatment technologies for pollutant treatment and reclaimed water production. The simulation results showed that from 2014 to 2020, Zaozhuang City will realize an annual GDP growth rate of 7.1% with an annual chemical oxygen demand (COD emissions reduction rate of 5.5%. The proportion of primary industry, secondary industry, and tertiary industry would be adjusted to 5.6%, 40.8%, and 53.6%, respectively. The amount of reclaimed water supply could be increased by 91% and groundwater supply could be decreased by 6%. Based on the simulation, this model proposes a scientific reference on water resources management policies, including water environment control, water supply plan, and financial subsidy, to realize the sustainable development of economy and water resources usage.

  18. The Research for the Greenhouse Water Evaporation Based on the Environmental Factors

    OpenAIRE

    Lili Ma; Chaoxing He; Zhixin Wang

    2013-01-01

    To guide the greenhouse precision irrigation, influenced by the environmental factors, based on the definite plant, the greenhouse water evaporation characteristics are studied. The qualitative and the quantitative relationships between the environmental factors and the greenhouse water evaporation are probed into which will provide the theoretical basis for the water management of the facilities horticulture. Establishing the quantitative relations between the environmental factors and the w...

  19. Characterization factors for water footprint considering the scarcity of green and blue water sources

    Science.gov (United States)

    Oki, T.; Kondo, T.; Pokhrel, Y. N.; Hanasaki, N.

    2011-12-01

    The original concept of virtual water trade was invented to illustrate how much water demand can be reduced by importing food products (Allan 1996), and expanded for meat products and industrial products (Oki and Kanae, 2004). However, there was a confusion between "virtual trade of water" (original) and "trade of virtual water" (misinterpretation but widely accepted), and "virtual water" has been recognized as how much water was used to produce the commodity. Then, the concept has some analogy to carbon footprint (CFP) which is an indicator of total emission of greenhouse gases, and nowadays called water footprint (WFP, Hoekstra, 2004). However, WFP itself is just an inventory of water usages under the framework of life cycle assessment (LCA), and the volume of WFP does not necessary reflect the environmental impacts of water usages because consumptive water use of 100 liter from ground water in arid regions just before rainy season would have more environmental impacts than consumptive water use of 100 liter from rain water in humid regions during snow melt season. In the case of CFP, the emissions of five greenhouse gases except for CO2 were converted into CO2 equivalent volumes by considering the sensitivity for the global warming potential, and summed up into CFP. Here, we propose a new idea objectively determining the weights (characterization factors) for blue water usages, such as from river and ground water, to be converted into green water equivalent in each region and time. The weights are inversely proportional to the area required to obtain the same amount of green water, and water balance model can provide the basic information. The new concept was applied to the WFP of Japan through the imports of major crops. As an inventory, WFP was 15.5 km3/y of rain water, 2.2 km3/y of river water, and 2.0 km3/y of non-renewable and non-local water (NRNL water) for year 2000, however, considering the proposed characterization factors in each region (0.5 x 0

  20. Factors affecting ground-water exchange and catchment size for Florida lakes in mantled karst terrain

    Science.gov (United States)

    Lee, Terrie Mackin

    2002-01-01

    In the mantled karst terrain of Florida, the size of the catchment delivering ground-water inflow to lakes is often considerably smaller than the topographically defined drainage basin. The size is determined by a balance of factors that act individually to enhance or diminish the hydraulic connection between the lake and the adjacent surficial aquifer, as well as the hydraulic connection between the surficial aquifer and the deeper limestone aquifer. Factors affecting ground-water exchange and the size of the ground-water catchment for lakes in mantled karst terrain were examined by: (1) reviewing the physical and hydrogeological characteristics of 14 Florida lake basins with available ground-water inflow estimates, and (2) simulating ground-water flow in hypothetical lake basins. Variably-saturated flow modeling was used to simulate a range of physical and hydrogeologic factors observed at the 14 lake basins. These factors included: recharge rate to the surficial aquifer, thickness of the unsaturated zone, size of the topographically defined basin, depth of the lake, thickness of the surficial aquifer, hydraulic conductivity of the geologic units, the location and size of karst subsidence features beneath and onshore of the lake, and the head in the Upper Floridan aquifer. Catchment size and the magnitude of ground-water inflow increased with increases in recharge rate to the surficial aquifer, the size of the topographically defined basin, hydraulic conductivity in the surficial aquifer, the degree of confinement of the deeper Upper Floridan aquifer, and the head in the Upper Floridan aquifer. The catchment size and magnitude of ground-water inflow increased with decreases in the number and size of karst subsidence features in the basin, and the thickness of the unsaturated zone near the lake. Model results, although qualitative, provided insights into: (1) the types of lake basins in mantled karst terrain that have the potential to generate small and large

  1. Limiting factor analysis of high availability nuclear plants (boiling water reactors). Final report

    International Nuclear Information System (INIS)

    Frederick, L.G.; Brady, R.M.; Shor, S.W.W.; McCusker, J.T.; Alden, W.M.; Kovacs, S.

    1979-08-01

    The pertinent results are presented of a 16-month study conducted for Electric Power Research Institute by General Electric Company, Bechtel Power Corporation, and Philadelphia Electric Company. The study centered around the Peach Bottom 2 Atomic Power Station, but also included limited study of operations at 20 additional operating boiling water reactors. The purpose of the study was to identify and evaluate key factors limiting plant availability, and to identify potential improvements for eliminating or alleviating those limitations. The key limiting factors were found to be refueling activities; activities related to the reactor fuel; reactor scrams; activities related to 20 operating systems or major components; delays due to radiation, turbid water during refueling operations, facilities/working conditions, and dirt/foreign material; and general maintenance/repair of valves and piping. Existing programs to reduce the effect on plant unavailability are identified, and suggestions for further action are made

  2. Impact analysis and testing of tritiated heavy water transportation packages including hydrodynamic effects

    International Nuclear Information System (INIS)

    Sauve, R.G.; Tulk, J.D.; Gavin, M.E.

    1989-01-01

    Ontario Hydro has recently designed a new Type B(M) Tritiated Heavy Water Transportation Package (THWTP) for the road transportation of tritiated heavy water from its operating nuclear stations to the Tritium Removal Facility in Ontario. These packages must demonstrate the ability to withstand severe shock and impact scenarios such as those prescribed by IAEA standards. The package, shown in figure 1, comprises an inner container filled with tritiated heavy water, and a 19 lb/ft 3 polyurethane foam-filled overpack. The overpack is of sandwich construction with 304L stainless steel liners and 10.5 inch thick nominal foam walls. The outer shell is 0.75 inch thick and the inner shell is 0.25 inch thick. The primary containment boundary consists of the overpack inner liner, the containment lid and outer containment seals in the lid region. The total weight of the container including the 12,000 lb. payload is 36,700 lb. The objective of the present study is to evaluate the hydrodynamic effect of the tritiated heavy water payload on the structural integrity of the THWTP during a flat end drop from a height of 9 m. The study consisted of three phases: (i) developing an analytical model to simulate the hydrodynamic effects of the heavy water payload during impact; (ii) performing an impact analysis for a 9 m flat end drop of the THWTP including fluid structure interaction; (iii) verification of the analytical models by experiment

  3. NDMA formation during drinking water treatment: A multivariate analysis of factors influencing formation.

    Science.gov (United States)

    Leavey-Roback, Shannon L; Sugar, Catherine A; Krasner, Stuart W; Suffet, Irwin H Mel

    2016-05-15

    The formation of the carcinogen N-nitrosodimethylamine (NDMA) during drinking water treatment has raised concerns in the drinking water industry. Many bench-scale laboratory tests and pilot plant studies have been completed to try to determine which factors during water treatment increase or decrease the amount of NDMA formed in drinking water. This study used data from over 20 drinking water treatment plants in the United States and Canada to determine which factors are most highly correlated with the NDMA concentration in delivered water using a mixed effects model with a random intercept. This type of analysis has not been used previously with trihalomethane (THM) models due to the fact that those studies did not sample such a large number and range of plants as was done in this NDMA study. Ultraviolet absorbance at 254 nm (UV254) in the plant influent and pre-chlorination time used at the plant were highly correlated in all models with NDMA concentration in finished water as well as the percentage change between NDMA formation potential in the plant influent and actual formation in the finished water. Specifically, an increase in UV254 absorbance in a model was associated with an increase in NDMA and an increase in pre-chlorination time in a model was associated with a decrease in NDMA. Other water quality parameters including sucralose concentration in the plant influent, polyDADMAC polymer dose, pH, and chlorine-to-ammonia weight ratio used in the plant were also correlated with NDMA concentration in the distribution system. Lastly, NDMA precursor loading was correlated with the use of polyDADMAC (where precursors were added) and the use of ozone and granular activated carbon (GAC) treatment (where precursors were removed). Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. 43 CFR 404.9 - What types of infrastructure and facilities may be included in an eligible rural water supply...

    Science.gov (United States)

    2010-10-01

    ... facilities may be included in an eligible rural water supply project? 404.9 Section 404.9 Public Lands... RURAL WATER SUPPLY PROGRAM Overview § 404.9 What types of infrastructure and facilities may be included in an eligible rural water supply project? A rural water supply project may include, but is not...

  5. Environmental factors related to water level regulation - a comparative study in northern Finland

    International Nuclear Information System (INIS)

    Hellsten, S.K.

    1997-01-01

    The environmental conditions of the littoral zone were studied in the regulated Lake Ontojaervi and the unregulated Lake Lentua in northern Finland. The general aims of the study were to analyse the environmental factors related to water level regulation in the littoral zone and to produce information for assessing the effects of hydroelectric development in northern lakes. The study was basically carried out by comparing the littoral environments of the two study lakes. The most visible effects of water level regulation were related to the raised water level, which yielded erosion of sandy shores at the beginning of the regulation. Another effect of lake regulation was the altered fluctuation of the water level, which led to bottom instability and increased the size of the frozen and ice penetration zones. The effect of ice penetration was also easy to recognize on the shores of Lake Ontojaervi, where the surface sediment was frozen to a greater depth and across wider areas than in Lake Lentua. Below the freezing zone, the ice just pressed down on the sediment. The shores of Lake Ontojaervi were steeper than those of Lake Lentua, which affected the distribution of bottom types, with sandy bottoms being more common in Lake Lentua than in Lake Ontojaervi. The factors related to site exposure included effective fetch and the shape of the shoreline. The sedimentation level correlated only with the slope and was not predicted by the fetch or shape. The vertical reduction of light was estimated on the basis of water colour. The main environmental factors from the two lakes were used in a discriminant analysis to predict the bottom type distribution of the littoral (r 2 = 0.41). (orig.) 66 refs

  6. Environmental factors related to water level regulation - a comparative study in northern Finland

    Energy Technology Data Exchange (ETDEWEB)

    Hellsten, S K [VTT Communities and Infrastructure. Water Engineering and Ecotechnology, Oulu (Finland)

    1998-12-31

    The environmental conditions of the littoral zone were studied in the regulated Lake Ontojaervi and the unregulated Lake Lentua in northern Finland. The general aims of the study were to analyse the environmental factors related to water level regulation in the littoral zone and to produce information for assessing the effects of hydroelectric development in northern lakes. The study was basically carried out by comparing the littoral environments of the two study lakes. The most visible effects of water level regulation were related to the raised water level, which yielded erosion of sandy shores at the beginning of the regulation. Another effect of lake regulation was the altered fluctuation of the water level, which led to bottom instability and increased the size of the frozen and ice penetration zones. The effect of ice penetration was also easy to recognize on the shores of Lake Ontojaervi, where the surface sediment was frozen to a greater depth and across wider areas than in Lake Lentua. Below the freezing zone, the ice just pressed down on the sediment. The shores of Lake Ontojaervi were steeper than those of Lake Lentua, which affected the distribution of bottom types, with sandy bottoms being more common in Lake Lentua than in Lake Ontojaervi. The factors related to site exposure included effective fetch and the shape of the shoreline. The sedimentation level correlated only with the slope and was not predicted by the fetch or shape. The vertical reduction of light was estimated on the basis of water colour. The main environmental factors from the two lakes were used in a discriminant analysis to predict the bottom type distribution of the littoral (r{sup 2} = 0.41). (orig.) 66 refs.

  7. Including Effects of Water Stress on Dead Organic Matter Decay to a Forest Carbon Model

    Science.gov (United States)

    Kim, H.; Lee, J.; Han, S. H.; Kim, S.; Son, Y.

    2017-12-01

    Decay of dead organic matter is a key process of carbon (C) cycling in forest ecosystems. The change in decay rate depends on temperature sensitivity and moisture conditions. The Forest Biomass and Dead organic matter Carbon (FBDC) model includes a decay sub-model considering temperature sensitivity, yet does not consider moisture conditions as drivers of the decay rate change. This study aimed to improve the FBDC model by including a water stress function to the decay sub-model. Also, soil C sequestration under climate change with the FBDC model including the water stress function was simulated. The water stress functions were determined with data from decomposition study on Quercus variabilis forests and Pinus densiflora forests of Korea, and adjustment parameters of the functions were determined for both species. The water stress functions were based on the ratio of precipitation to potential evapotranspiration. Including the water stress function increased the explained variances of the decay rate by 19% for the Q. variabilis forests and 7% for the P. densiflora forests, respectively. The increase of the explained variances resulted from large difference in temperature range and precipitation range across the decomposition study plots. During the period of experiment, the mean annual temperature range was less than 3°C, while the annual precipitation ranged from 720mm to 1466mm. Application of the water stress functions to the FBDC model constrained increasing trend of temperature sensitivity under climate change, and thus increased the model-estimated soil C sequestration (Mg C ha-1) by 6.6 for the Q. variabilis forests and by 3.1 for the P. densiflora forests, respectively. The addition of water stress functions increased reliability of the decay rate estimation and could contribute to reducing the bias in estimating soil C sequestration under varying moisture condition. Acknowledgement: This study was supported by Korea Forest Service (2017044B10-1719-BB01)

  8. Migration of carbon dioxide included micro-nano bubble water in porous media and its monitoring

    Science.gov (United States)

    Takemura, T.; Hamamoto, S.; Suzuki, K.; Koichi, O.

    2017-12-01

    The distributed CO2 storage is the small scale storage and its located near the emission areas. In the distributed CO2 storage, the CO2 is neutralized by sediment and underground water in the subsurface region (300-500m depth). Carbon dioxide (CO2) included micro-nano bubbles is one approach in neutralizing CO2 and sediments by increasing CO2 volume per unit volume of water and accelerating the chemical reaction. In order to design underground treatment for CO2 gas in the subsurface, it is required to elucidate the behavior of CO2 included micro-nano bubbles in the water. In this study, we carried out laboratory experiment using the soil tank, and measure the amount of leakage of CO2 gas at the surface. In addition, the process of migration of carbon dioxide included micro-nano bubble was monitored by the nondestructive method, wave velocity and resistivity.

  9. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  10. Differentiating the Spatiotemporal Distribution of Natural and Anthropogenic Processes on River Water-Quality Variation Using a Self-Organizing Map With Factor Analysis.

    Science.gov (United States)

    Wang, Yeuh-Bin; Liu, Chen-Wuing; Lee, Jin-Jing

    2015-08-01

    To elucidate the historical improvement and advanced measure of river water quality in the Taipei metropolitan area, this study applied the self-organizing map (SOM) technique with factor analysis (FA) to differentiate the spatiotemporal distribution of natural and anthropogenic processes on river water-quality variation spanning two decades. The SOM clustered river water quality into five groups: very low pollution, low pollution, moderate pollution, high pollution, and very high pollution. FA was then used to extract four latent factors that dominated water quality from 1991 to 2011 including three anthropogenic process factors (organic, industrial, and copper pollution) and one natural process factor [suspended solids (SS) pollution]. The SOM revealed that the water quality improved substantially over time. However, the downstream river water quality was still classified as high pollution because of an increase in anthropogenic activity. FA showed the spatiotemporal pattern of each factor score decreasing over time, but the organic pollution factor downstream of the Tamsui River, as well as the SS factor scores in the upstream major tributary (the Dahan Stream), remained within the high pollution level. Therefore, we suggest that public sewage-treatment plants should be upgraded from their current secondary biological processing to advanced treatment processing. The conservation of water and soil must also be reinforced to decrease the SS loading of the Dahan Stream from natural erosion processes in the future.

  11. 78 FR 35929 - Proposed Listing of Additional Waters To Be Included on Indiana's 2010 List of Impaired Waters...

    Science.gov (United States)

    2013-06-14

    ... which existing technology-based pollution controls are not stringent enough to attain or maintain state... ENVIRONMENTAL PROTECTION AGENCY [FRL-9823-3] Proposed Listing of Additional Waters To Be Included...: Environmental Protection Agency (EPA). ACTION: Notice and request for comments. SUMMARY: This notice announces...

  12. Conservation-reuse of water in fossil-fuel power plants including water treatment plants

    Energy Technology Data Exchange (ETDEWEB)

    Rao, T.S.R.

    1984-02-01

    The various areas where the conservation-reuse of water is possible are discussed. However, water conservation, especially effluent volume reduction-treatment reuse, should be seen in the light of pollution control measures. Some of the areas indicated recover a small quantity of water but they should be viewed in the light of well yield being not adequate, or having high salinity or having an increase of well water salinity after some use. Some of the methods can only be adopted at the design stage whereas others could be incorporated at the site.

  13. Factors influencing sustainability of communally-managed water facilities in rural areas of Zimbabwe

    Science.gov (United States)

    Kativhu, T.; Mazvimavi, D.; Tevera, D.; Nhapi, I.

    2017-08-01

    Sustainability of point water facilities is a major development challenge in many rural settings of developing countries not sparing those in the Sub-Saharan Africa region. This study was done in Zimbabwe to investigate the factors influencing sustainability of rural water supply systems. A total of 399 water points were studied in Nyanga, Chivi and Gwanda districts. Data was collected using a questionnaire, observation checklist and key informant interview guide. Multi-Criteria analysis was used to assess the sustainability of water points and inferential statistical analysis such as Chi square tests and Analysis of Variance (ANOVA) were used to determine if there were significant differences on selected variables across districts and types of lifting devices used in the study area. The thematic approach was used to analyze qualitative data. Results show that most water points were not functional and only 17% across the districts were found to be sustainable. A fusion of social, technical, financial, environmental and institutional factors was found to be influencing sustainability. On technical factors the ANOVA results show that the type of lifting device fitted at a water point significantly influences sustainability (F = 37.4, p planning stage of water projects was also found to be critical for sustainability although field results showed passive participation by communities at this critical project stage. Financial factors of adequacy of financial contributions and establishment of operation and maintenance funds were also found to be of great importance in sustaining water supply systems. It is recommended that all factors should be considered when assessing sustainability since they are interrelated.

  14. Seminar Investigation of the effect of anthropogenic factors on water systems

    International Nuclear Information System (INIS)

    2004-01-01

    The present CD contains 59 presentations, presented on the seminar Investigation of the anthropogenic factors effect on water systems, held in Bratislava, Slovakia, 23-24 April 2003. The content of this Proceedings is divided into thematic groups: Precipitation, Global Climatic Changes, Rainfall-runoff Modelling, design Values; Quality of Water in Water streams; River Basin Management; Water Retention in River Basins, Effect of Forests, Urban Areas, River Training; Hydraulic Modelling of Flood Flow, Flood Plain Areas, Flood Maps; Sediment Transport in relation with Flood Discharges; Diffuse Sources of Pollution, Point Sources in River Basin; Surface Water and Groundwater Interaction; GIS Utilization for Problem Solution. Water management indirectly influences by its activities the social and economic development of Slovakia. Water as raw material for drinking water production as well as vital liquid and raw material enter almost all manufacturing processes. But water become also a destructive element that hit different locations of Slovak territory and cause damages on people and live animals as well as material damages. In economic utilizing of water and handling water, drainage and treatment, the principle of minimising negative impacts on the environment must be exercised having in mind sustaining, in for the future generations.Water management is struggling with a number of problems at the moment. The project Investigation of the anthropogenic factors effect on water systems is aiming to solve the most important issues like are surface and subsurface run, retention capacity of river basin. quality of surface and ground water, water interaction and other

  15. Universal cell frame for high-pressure water electrolyzer and electrolyzer including the same

    Science.gov (United States)

    Schmitt, Edwin W.; Norman, Timothy J.

    2013-01-08

    Universal cell frame generic for use as an anode frame and as a cathode frame in a water electrolyzer. According to one embodiment, the universal cell frame includes a unitary annular member having a central opening. Four trios of transverse openings are provided in the annular member, each trio being spaced apart by about 90 degrees. A plurality of internal radial passageways fluidly interconnect the central opening and each of the transverse openings of two diametrically-opposed trios of openings, the other two trios of openings lacking corresponding radial passageways. Sealing ribs are provided on the top and bottom surfaces of the annular member. The present invention is also directed at a water electrolyzer that includes two such cell frames, one being used as the anode frame and the other being used as the cathode frame, the cathode frame being rotated 90 degrees relative to the anode frame.

  16. Dose rate determining factors of PWR primary water

    International Nuclear Information System (INIS)

    Terachi, Takumi; Kuge, Toshiharu; Nakano, Nobuo

    2014-01-01

    The relationship between dose rate trends and water chemistry has been studied to clarify the determining factors on the dose rates. Therefore dose rate trends and water chemistry of 11 PWR plants of KEPCO (Kansai Electric Power Co., Inc.) were summarized. It is indicated that the chemical composition of the oxide film, behaviour of corrosion products and Co-58/Co-60 ratio in the primary system have effected dose rate trends based on plant operation experiences for over 40 years. According to plant operation experiences, the amount of Co-58 has been decreasing with the increasing duration of SG (Steam Generator) usage. It is indicated that the stable oxide film formation on the inner surface of SG tubing, is a major beneficial factor for radiation sources reduction. On the other hand, the reduction of the amount of Co-60 for the long term has been not clearly observed especially in particular high dose plants. The primary water parameters imply that considering release and purification balance on Co-59 is important to prevent accumulation of source term in primary water. In addition, the effect of zinc injection, which relates to the chemical composition of oxide film, was also assessed. As the results, the amount of radioactive Co has been clearly decreased. The decreasing trend seems to correlate to the half-life of Co-60, because it is considered that the injected zinc prevents the uptake of radioactive Co into the oxide film on the inner surface of the components and piping. In this paper, the influence of water chemistry and the replacement experiences of materials on the dose rates were discussed. (author)

  17. Escherichia coli Contamination across Multiple Environmental Compartments (Soil, Hands, Drinking Water, and Handwashing Water) in Urban Harare: Correlations and Risk Factors.

    Science.gov (United States)

    Navab-Daneshmand, Tala; Friedrich, Max N D; Gächter, Marja; Montealegre, Maria Camila; Mlambo, Linn S; Nhiwatiwa, Tamuka; Mosler, Hans-Joachim; Julian, Timothy R

    2018-03-01

    Escherichia coli pathotypes (i.e., enteropathogenic and enterotoxigenic) have been identified among the pathogens most responsible for moderate-to-severe diarrhea in low- and middle-income countries (LMICs). Pathogenic E. coli are transmitted from infected human or animal feces to new susceptible hosts via environmental reservoirs such as hands, water, and soil. Commensal E. coli , which includes nonpathogenic E. coli strains, are widely used as fecal bacteria indicator, with their presence associated with increased likelihood of enteric pathogens and/or diarrheal disease. In this study, we investigated E. coli contamination in environmental reservoirs within households ( N = 142) in high-population density communities of Harare, Zimbabwe. We further assessed the interconnectedness of the environmental compartments by investigating associations between, and household-level risk factors for, E. coli contamination. From the data we collected, the source and risk factors for E. coli contamination are not readily apparent. One notable exception is the presence of running tap water on the household plot, which is associated with significantly less E. coli contamination of drinking water, handwashing water, and hands after handwashing. In addition, E. coli levels on hands after washing are significantly associated with handwashing water contamination, hand contamination before washing, and diarrhea incidence. Finally, we observed that animal ownership increases E. coli contamination in soil, and E. coli in soil are correlated with contamination on hands before washing. This study highlights the complexity of E. coli contamination in household environments within LMICs. More, larger, studies are needed to better identify sources and exposure pathways of E. coli -and enteric pathogens generally-to identify effective interventions.

  18. Fascioliasis and Eosinophilia in the Highlands of Cuzco, Peru and Their Association with Water and Socioeconomic Factors

    Science.gov (United States)

    Cabada, Miguel M.; Goodrich, Mary R.; Graham, Brittany; Villanueva-Meyer, Pablo G.; Lopez, Martha; Arque, Eulogia; White, A. Clinton

    2014-01-01

    There are limited data about the epidemiology of fascioliasis in Cuzco, Peru. We studied children 3–12 years old from six communities in the highlands of Cuzco to evaluate the epidemiology of fascioliasis; 227 children were included, one-half were female, the mean age was 7.5 (±2.6) years, and 46.2±% had one or more parasites, including Fasciola (9.7%), Ascaris (12.8%), Hymenolepis (9.3%), Trichuris (1.3%), hookworm (1.8%), Strongyloides (0.9%), and Giardia (27.8%). Fasciola was associated with the number of siblings in the household, drinking untreated water, and giardiasis. Eosinophilia was encountered in 21% of children and more common in those drinking untreated water at home and those infected with a parasite, but the differences were not significant. Eating water plants was not associated with Fasciola or eosinophilia. Fascioliasis and eosinophilia were common in the highlands of Cuzco. Fascioliasis was associated with socioeconomic factors and drinking water. PMID:25200257

  19. Fascioliasis and eosinophilia in the highlands of Cuzco, Peru and their association with water and socioeconomic factors.

    Science.gov (United States)

    Cabada, Miguel M; Goodrich, Mary R; Graham, Brittany; Villanueva-Meyer, Pablo G; Lopez, Martha; Arque, Eulogia; White, A Clinton

    2014-11-01

    There are limited data about the epidemiology of fascioliasis in Cuzco, Peru. We studied children 3-12 years old from six communities in the highlands of Cuzco to evaluate the epidemiology of fascioliasis; 227 children were included, one-half were female, the mean age was 7.5 (±2.6) years, and 46.2±% had one or more parasites, including Fasciola (9.7%), Ascaris (12.8%), Hymenolepis (9.3%), Trichuris (1.3%), hookworm (1.8%), Strongyloides (0.9%), and Giardia (27.8%). Fasciola was associated with the number of siblings in the household, drinking untreated water, and giardiasis. Eosinophilia was encountered in 21% of children and more common in those drinking untreated water at home and those infected with a parasite, but the differences were not significant. Eating water plants was not associated with Fasciola or eosinophilia. Fascioliasis and eosinophilia were common in the highlands of Cuzco. Fascioliasis was associated with socioeconomic factors and drinking water. © The American Society of Tropical Medicine and Hygiene.

  20. Surface water acidification and critical loads: exploring the F-factor

    Directory of Open Access Journals (Sweden)

    K. Bishop

    2009-11-01

    Full Text Available As acid deposition decreases, uncertainties in methods for calculating critical loads become more important when judgements have to be made about whether or not further emission reductions are needed. An important aspect of one type of model that has been used to calculate surface water critical loads is the empirical F-factor which estimates the degree to which acid deposition is neutralised before it reaches a lake at any particular point in time relative to the pre-industrial, steady-state water chemistry conditions.

    In this paper we will examine how well the empirical F-functions are able to estimate pre-industrial lake chemistry as lake chemistry changes during different phases of acidification and recovery. To accomplish this, we use the dynamic, process-oriented biogeochemical model SAFE to generate a plausible time series of annual runoff chemistry for ca. 140 Swedish catchments between 1800 and 2100. These annual hydrochemistry data are then used to generate empirical F-factors that are compared to the "actual" F-factor seen in the SAFE data for each lake and year in the time series. The dynamics of the F-factor as catchments acidify, and then recover are not widely recognised.

    Our results suggest that the F-factor approach worked best during the acidification phase when soil processes buffer incoming acidity. However, the empirical functions for estimating F from contemporary lake chemistry are not well suited to the recovery phase when the F-factor turns negative due to recovery processes in the soil. This happens when acid deposition has depleted the soil store of BC, and then acid deposition declines, reducing the leaching of base cations to levels below those in the pre-industrial era. An estimate of critical load from water chemistry during recovery and empirical F functions would therefore result in critical loads that are too low. Therefore, the empirical estimates of the F-factor are a significant source of

  1. Water Chemistry and Clad Corrosion/Deposition Including Fuel Failures. Proceedings of a Technical Meeting

    International Nuclear Information System (INIS)

    2013-03-01

    Corrosion is a principal life limiting degradation mechanism in nuclear steam supply systems, particularly taking into account the trends in increasing fuel burnup, thermal ratings and cycle length. Further, many plants have been operating with varying water chemistry regimes for many years, and issues of crud (deposition of corrosion products on other surfaces in the primary coolant circuit) are of significant concern for operators. At the meeting of the Technical Working Group on Fuel Performance and Technology (TWGFPT) in 2007, it was recommended that a technical meeting be held on the subject of water chemistry and clad corrosion and deposition, including the potential consequences for fuel failures. This proposal was supported by both the Technical Working Group on Advanced Technologies for Light Water Reactors (TWG-LWR) and the Technical Working Group on Advanced Technologies for Heavy Water Reactors (TWG-HWR), with a recommendation to hold the meeting at the National Nuclear Energy Generating Company ENERGOATOM, Ukraine. This technical meeting was part of the IAEA activities on water chemistry, which have included a series of coordinated research projects, the most recent of which, Optimisation of Water Chemistry to Ensure Reliable Water Reactor Fuel Performance at High Burnup and in Ageing Plant (FUWAC) (IAEATECDOC-1666), concluded in 2010. Previous technical meetings were held in Cadarache, France (1985), Portland, Oregon, USA (1989), Rez, Czech Republic (1993), and Hluboka nad Vltavou, Czech Republic (1998). This meeting focused on issues associated with the corrosion of fuel cladding and the deposition of corrosion products from the primary circuit onto the fuel assembly, which can cause overheating and cladding failure or lead to unplanned power shifts due to boron deposition in the clad deposits. Crud deposition on other surfaces increases radiation fields and operator dose and the meeting considered ways to minimize the generation of crud to avoid

  2. Clean water, sanitation and diarrhoea in Indonesia: Effects of household and community factors.

    Science.gov (United States)

    Komarulzaman, Ahmad; Smits, Jeroen; de Jong, Eelke

    2017-09-01

    Diarrhoea is an important health issue in low- and middle-income countries, including Indonesia. We applied a multilevel regression analysis on the Indonesian Demographic and Health Survey to examine the effects of drinking water and sanitation facilities at the household and community level on diarrhoea prevalence among children under five (n = 33,339). The role of the circumstances was explored by studying interactions between the water and sanitation variables and other risk factors. Diarrhoea prevalence was reported by 4820 (14.4%) children, who on average were younger, poorer and were living in a poorer environment. At the household level, piped water was significantly associated with diarrhoea prevalence (OR = 0.797, 95% CI: 0.692-0.918), improved sanitation had no direct effect (OR = 0.992, 95% CI: 0.899-1.096) and water treatment was not related to diarrhoea incidence (OR = 1.106, 95% CI: 0.994-1.232). At the community level, improved water coverage had no direct effect (OR = 1.002, 95% CI: 0.950-1.057) but improved sanitation coverage was associated with lower diarrhoea prevalence (OR = 0.917, 95% CI: 0.843-0.998). Our interaction analysis showed that the protective effects of better sanitation at the community level were increased by better drinking water at the community level. This illustrates the importance of improving both drinking water and sanitation simultaneously.

  3. Modelling of safety barriers including human and organisational factors to improve process safety

    DEFF Research Database (Denmark)

    Markert, Frank; Duijm, Nijs Jan; Thommesen, Jacob

    2013-01-01

    It is believed that traditional safety management needs to be improved on the aspect of preparedness for coping with expected and unexpected deviations, avoiding an overly optimistic reliance on safety systems. Remembering recent major accidents, such as the Deep Water Horizon, the Texas City....... A valuable approach is the inclusion of human and organisational factors into the simulation of the reliability of the technical system using event trees and fault trees and the concept of safety barriers. This has been demonstrated e.g. in the former European research project ARAMIS (Accidental Risk...

  4. ANALYSIS OF FACTORS CAUSING WATER DAMAGE TO LOESS DOUBLE-ARCHED TUNNEL BASED ON TFN-AHP

    Directory of Open Access Journals (Sweden)

    Mao Zheng-jun

    2017-04-01

    Full Text Available In order to analysis the factors causing water damage to loess double-arched tunnel, this paper conducts field investigation on water damage to tunnels on Lishi-Jundu Expressway in Shanxi, China, confirms its development characteristics, builds an index system (covering 36 evaluation indexes for construction condition, design stage, construction stage, and operation stage for the factors causing water damage to loess double-arched tunnel, applies TFN-AHP (triangular fuzzy number-analytic hierarchy process in calculating the weight of indexes at different levels, and obtains the final sequence of weight of the factors causing water seepage to loess double-arched tunnel. It is found out that water damage to loess double-arched tunnel always develops in construction joints, expansion joints, settlement joints, and lining joints of tunnel and even around them; there is dotted water seepage, linear water seepage, and planar water seepage according to the trace and scope of water damage to tunnel lining. The result shows that water damage to loess double-arched tunnel mainly refers to linear water seepage, planar water seepage is also developed well, and partition and equipment box at the entrance and exit of tunnel are prone to water seepage; construction stage is crucial for controlling water damage to loess double-arched tunnel, atmospheric precipitation is the main water source, and the structure defect of double-arched tunnel increases the possibility of water seepage; the final sequence for weight of various factors is similar to the actual result.

  5. Deuterium isotope separation factor between hydrogen and liquid water

    International Nuclear Information System (INIS)

    Rolston, J.H.; den Hartog, J.; Butler, J.P.

    1976-01-01

    The overall deuterium isotope separation factor between hydrogen and liquid water, α, has been measured directly for the first time between 280 and 370 0 K. The data are in good agreement with values of α calculated from literature data on the equilibrium constant for isotopic exchange between hydrogen and water vapor, K 1 , and the liquid-vapor separation factor, α/sub V/. The temperature dependence of α over the range 273-473 0 K based upon these new experimental results and existing literature data is given by the equation ln α = -0.2143 + (368.9/T) + (27,870/T 2 ). Measurements on α/sub V/ given in the literature have been surveyed and the results are summarized over the same temperature range by the equation ln α/sub V/ = 0.0592 - (80.3/T) +

  6. FACTORS AFFECTING GROUND WATER POLLUTION IN THE MEADOW OF BORCEA ARM

    Directory of Open Access Journals (Sweden)

    Cecilia NEAGU

    2014-04-01

    Full Text Available This paper aims to study the factors leading to water pollution by nitrates in the Meadow of Borcea arm, mainly derived from agricultural sources. mIn oder to model the amount of nitrate nitrogen in the soil, which can be partially used by plants or leached into the ground water, research was made on alluvial soil in the Meadow of Borcea arm. I tried to study in the laboratory the influence of three factors of nitrate nitrogen pollution of ground water: soil type, environmental conditions (temperature and humidity and the amount of mineral fertilizers incorporated. The resulting amount of nitrate nitrogen resulted with nitrogen fertilizer dose, and the temperature and it was affected by humidity especially 40-80% of field capacity.

  7. Integrating Process and Factor Understanding of Environmental Innovation by Water Utilities

    NARCIS (Netherlands)

    Spiller, Marc; McIntosh, Brian S.; Seaton, Roger A.F.; Jeffrey, Paul J.

    2015-01-01

    Innovations in technology and organisations are central to enabling the water sector to adapt to major environmental changes such as climate change, land degradation or drinking water pollution. While there are literatures on innovation as a process and on the factors that influence it, there is

  8. Factors affecting domestic water consumption in rural households upon access to improved water supply: insights from the Wei River Basin, China

    NARCIS (Netherlands)

    Fan, L.; Liu, G.; Wang, F.; Geissen, V.; Ritsema, C.J.

    2013-01-01

    Comprehensively understanding water consumption behavior is necessary to design efficient and effective water use strategies. Despite global efforts to identify the factors that affect domestic water consumption, those related to domestic water use in rural regions have not been sufficiently

  9. Electrolytic separation factors for oxygen isotopes in light and heavy water solutions

    International Nuclear Information System (INIS)

    Gulens, J.; Olmstead, W.J.; Longhurst, T.H.; Gale, K.L.; Rolston, J.H.

    1987-01-01

    The electrolytic separation factor, α, has been measured for /sup 17/O and /sup 18/O at Pt and Ni anodes in both light and heavy water solutions of 6M KOH as a function of current density. For oxygen-17, isotopic separation effects were not observed, within the experimental uncertainty of +-2%, under all conditions studied. For oxygen-18, there is a small difference of 2% in α values between Pt and Ni in both light and heavy water solutions, but there is no significant difference in α values between light and heavy water solutions. In light waters solutions, the separation factor at Pt is small, α(/sup 18/O) ≤ 1.02 for i ≥ 0.1 A/cm/sub 2/. This value agrees reasonably well with theoretical estimates

  10. Sediment-to-Water Partition Coefficients: the Influence of Physicochemical and Seasonal Factors in Eastern Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Yankovich, Tamara L. [International Atomic Energy Agency, P.O. Box 100, 1400 Vienna (Austria); Shultz, Carmen; Hartwig, Dale; Wills, C. Anne [Atomic Energy of Canada Limited, Chalk River Laboratories, Chalk River, Ontario, K0J 1J0 (Canada); Beresford, Nicholas A. [NERC Centre for Ecology and Hydrology, Lancaster Environment Center, Library Av., Bailrigg, Lancaster, LA1 4AP (United Kingdom); School of Environment and Life Sciences, University of Salford, Manchester, M4 4WT (United Kingdom); Wood, Michael D. [School of Environment and Life Sciences, University of Salford, Manchester, M4 4WT (United Kingdom)

    2014-07-01

    Sediments often represent an important reservoir for contaminants, such as radionuclides and metals, in aquatic ecosystems. Consequently, lake, stream, and river sediments can potentially act as significant contributors to the total contaminant exposure and radiological doses received by wildlife. Exposure to contaminated sediments is dependent upon several factors. These include net contaminant inputs to a system through time, the physicochemical attributes of the system, the tendency of each contaminant to partition into the sediments relative to water, the spatial distribution of contaminants in the sediments, and the behaviour or life-style of the biota inhabiting a water body. Increased understanding of such factors and their interactions will lead to improved predictions of the radionuclide exposure received by aquatic biota, particularly benthic organisms. Despite the complexity and the dynamic nature of sediments in general, for practical purposes, in environmental impact assessments (EIAs), it is often assumed that radionuclide activity concentrations in various compartments are at steady state with respect to one another. Therefore, ratios can be used to estimate concentrations in one compartment given a known concentration in another. In the case of sediments, sediment-to-water partition coefficients (K{sub d}) are often applied to estimate the contaminant concentration sorbed to particulate matter relative to the concentration measured in the surface water. However, K{sub d} values often range by several orders of magnitude between sampling locations due to site-specific differences in physicochemical conditions in surface waters, seasonal factors, as well as differences in sediment attributes that can affect contaminant partitioning between the dissolved and particulate phases. Consequently, in conducting EIAs, it becomes necessary to either apply generic K{sub d} values that ensure contaminant concentrations in sediments to which biota are exposed are

  11. Ground-water heat pumps: an examination of hydrogeologic, environmental, legal, and economic factors affecting their use

    Energy Technology Data Exchange (ETDEWEB)

    Armitage, D M; Bacon, D J; Massey-Norton, J T; Miller, J D

    1980-11-12

    Groundwater is attractive as a potential low-temperature energy source in residential space-conditioning applications. When used in conjuncton with a heat pump, ground water can serve as both a heat source (for heating) and a heat sink (for cooling). Major hydrogeologic aspects that affect system use include groundwater temperature and availability at shallow depths as these factors influence operational efficiency. Ground-water quality is considered as it affects the performance and life-expectancy of the water-side heat exchanger. Environmental impacts related to groundwater heat pump system use are most influenced by water use and disposal methods. In general, recharge to the subsurface (usually via injection wells) is recommended. Legal restrictions on system use are often stricter at the municipal and county levels than at state and Federal levels. Although Federal regulations currently exist, the agencies are not equipped to regulate individual, domestic installations. Computer smulations indicate that under a variety of climatologic conditions, groundwater heat pumps use less energy than conventional heating and cooling equipment. Life-cycle cost comparisons with conventional equipment depend on alternative system choices and well cost options included in the groundwater heat pump system.

  12. Self-absorption alpha particle factor in water: interest in the monitoring of specific military sites

    International Nuclear Information System (INIS)

    Cazoulat, A.; Lecompte, Y.; Bohand, S.; Gerasimo, P.

    2007-01-01

    Self-absorption alpha particle factor validation in water: Interest in the monitoring of specific military sites. The population internal intake prevention by radionuclides present in water needs to monitor the radioactive Level of this water. The French public health legislation introduces four radiological parameters for monitoring water, such as the gross alpha radioactivity. Regarding the alpha particle characteristics, a self-absorption factor has to be established beforehand, not to underestimate the real alpha radioactivity in water samples. The aim of this paper is to describe the procedure used by the laboratory of the French army radioprotection service to determine this f factor, which depends on the water residue mass m after evaporation. The relation is f = 0.0253 m + 1.2813. This formula can be employed for such waters used in this experiment and for masses between 0 and 100 mg. The uncertainty associated is about 11% (k = 2). Some water monitoring examples are given. It is specially the case of depleted uranium shells experiment centres, localized in Gramat and Bourges. (authors)

  13. Study and mitigation of calibration factor instabilities in a water vapor Raman lidar

    Directory of Open Access Journals (Sweden)

    L. David

    2017-07-01

    Full Text Available We have investigated calibration variations in the Rameau water vapor Raman lidar. This lidar system was developed by the Institut National de l'Information Géographique et Forestière (IGN together with the Laboratoire Atmosphères, Milieux, Observations Spatiales (LATMOS. It aims at calibrating Global Navigation Satellite System (GNSS measurements for tropospheric wet delays and sounding the water vapor variability in the lower troposphere. The Rameau system demonstrated good capacity in retrieving water vapor mixing ratio (WVMR profiles accurately in several campaigns. However, systematic short-term and long-term variations in the lidar calibration factor pointed to persistent instabilities. A careful testing of each subsystem independently revealed that these instabilities are mainly induced by mode fluctuations in the optic fiber used to couple the telescope to the detection subsystem and by the spatial nonuniformity of the photomultiplier photocathodes. Laboratory tests that replicate and quantify these instability sources are presented. A redesign of the detection subsystem is presented, which, combined with careful alignment procedures, is shown to significantly reduce the instabilities. Outdoor measurements were performed over a period of 5 months to check the stability of the modified lidar system. The calibration changes in the detection subsystem were monitored with lidar profile measurements using a common nitrogen filter in both Raman channels. A short-term stability of 2–3 % and a long-term drift of 2–3 % per month are demonstrated. Compared to the earlier Development of Methodologies for Water Vapour Measurement (DEMEVAP campaign, this is a 3-fold improvement in the long-term stability of the detection subsystem. The overall water vapor calibration factors were determined and monitored with capacitive humidity sensor measurements and with GPS zenith wet delay (ZWD data. The changes in the water vapor calibration factors

  14. Improvements in scaling of counter-current imbibition recovery curves using a shape factor including permeability anisotropy

    Science.gov (United States)

    Abbasi, Jassem; Sarafrazi, Shiva; Riazi, Masoud; Ghaedi, Mojtaba

    2018-02-01

    Spontaneous imbibition is the main oil production mechanism in the water invaded zone of a naturally fractured reservoir (NFR). Different scaling equations have been presented in the literature for upscaling of core scale imbibition recovery curves to field scale matrix blocks. Various scale dependent parameters such as gravity effects and boundary influences are required to be considered in the upscaling process. Fluid flow from matrix blocks to the fracture system is highly dependent on the permeability value in the horizontal and vertical directions. The purpose of this study is to include permeability anisotropy in the available scaling equations to improve the prediction of imbibition assisted oil production in NFRs. In this paper, a commercial reservoir simulator was used to obtain imbibition recovery curves for different scenarios. Then, the effect of permeability anisotropy on imbibition recovery curves was investigated, and the weakness of the existing scaling equations for anisotropic rocks was demonstrated. Consequently, an analytical shape factor was introduced that can better scale all the curves related to anisotropic matrix blocks.

  15. Direct measurement of electron beam quality conversion factors using water calorimetry.

    Science.gov (United States)

    Renaud, James; Sarfehnia, Arman; Marchant, Kristin; McEwen, Malcolm; Ross, Carl; Seuntjens, Jan

    2015-11-01

    In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9-20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%-0.40%) and its influence on the perturbation correction (Type B, 0.10%-0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, kecal, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM's TG-51 protocol. General agreement between the relative

  16. Geological Factors Affecting Flow Spatial Continuity in Water Injection of Units Operating in the LGITJ–0102 Ore Body

    Directory of Open Access Journals (Sweden)

    Ilver M. Soto-Loaiza

    2016-05-01

    Full Text Available The objective of the investigation was to identify the geological factors affecting the spatial continuity of the flow during the process of flank water injection in the units operating in the Lower Lagunilla Hydrocarbon Ore Body. This included the evaluation of the recovery factor, the petro-physic properties such as porosity, permeability, water saturation and rock type and quality in each flow unit. it was observed that the rock type of the geologic structure in the ore body is variable. The lowest values for the petro-physic properties were found in the southern area while a high variability of these parameters was observed in the northern and central areas. It was concluded that the northern area has a great potential for the development of new injection projects for petroleum recovery.

  17. Revised emission factors for gas engines including start/stop emissions

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Malene; Boll Illerup, J.; Birr-Petersen, K.

    2008-06-15

    Liberalisation of the electricity market has led to Danish gas engine plants increasingly converting to the spot and regulating power markets. In order to offer regulating power, plants need to be able to start and stop the engines at the plants quickly. The liberalisation causes a considerable change of operation practice of the engines e.g. less full load operation hours /year. The project provides an inventory determining the scale of the emissions during the start and stop sequence as well as proposals for engine modifications aimed at reducing start/stop emissions. This report includes calculation of emission factors as well as an inventory of total emissions and reduction potentials. (au)

  18. Arsenic in Drinking Water in Bangladesh: Factors Affecting Child Health

    Science.gov (United States)

    Aziz, Sonia N.; Aziz, Khwaja M. S.; Boyle, Kevin J.

    2014-01-01

    The focus of this paper is to present an empirical model of factors affecting child health by observing actions households take to avoid exposure to arsenic in drinking water. Millions of Bangladeshis face multiple health hazards from high levels of arsenic in drinking water. Safe water sources are either expensive or difficult to access, affecting people’s individuals’ time available for work and ultimately affecting the health of household members. Since children are particularly susceptible and live with parents who are primary decision makers for sustenance, parental actions linking child health outcomes is used in the empirical model. Empirical results suggest that child health is significantly affected by the age and gender of the household water procurer. Adults with a high degree of concern for children’s health risk from arsenic contamination, and who actively mitigate their arsenic contaminated water have a positive effect on child health. PMID:24982854

  19. Environmental setting and factors that affect water quality in the Georgia-Florida Coastal Plain study unit

    Science.gov (United States)

    Berndt, M.P.; Oaksford, E.T.; Darst, M.R.; Marella, R.L.

    1996-01-01

    , geologic setting, ground-water systems, surface- water systems, climate, floods, droughts, population, land use, and water use. Factors affecting water quality in the study area are land use (primarily urban and agricultural land uses), water use in coastal areas, hydrogeology, ground-water/surface-water interaction, geology, and climate. Surface-water quality problems in urban areas have occurred in the Ogeechee, Canoochee, Ocmulgee, St. Marys, Alapaha, Withlacoochee (north), Santa Fe, Ochlockonee, St. Johns, and Oklawaha Rivers and include nitrogen and phosphorus loading, low dissolved oxygen, elevated bacteria, sediment, and turbidity, and increased concentrations of metals. In agricultural areas, surface-water quality problems include elevated nitrogen and phosphorus concentrations, erosion, and sedimentation and have occurred in the Ocmulgee, St. Marys, Santa Fe, Ochlockonee, St. Johns, Oklawaha, Withlacoochee (South), Hillsborough, and Alafia Rivers. Ground water-quality problems such as saltwater intrusion have occurred mostly in coastal areas and were caused by excessive withdrawals.

  20. Experimental test of a hot water storage system including a macro-encapsulated phase change material (PCM)

    Science.gov (United States)

    Mongibello, L.; Atrigna, M.; Bianco, N.; Di Somma, M.; Graditi, G.; Risi, N.

    2017-01-01

    Thermal energy storage systems (TESs) are of fundamental importance for many energetic systems, essentially because they permit a certain degree of decoupling between the heat or cold production and the use of the heat or cold produced. In the last years, many works have analysed the addition of a PCM inside a hot water storage tank, as it can allow a reduction of the size of the storage tank due to the possibility of storing thermal energy as latent heat, and as a consequence its cost and encumbrance. The present work focuses on experimental tests realized by means of an indoor facility in order to analyse the dynamic behaviour of a hot water storage tank including PCM modules during a charging phase. A commercial bio-based PCM has been used for the purpose, with a melting temperature of 58°C. The experimental results relative to the hot water tank including the PCM modules are presented in terms of temporal evolution of the axial temperature profile, heat transfer and stored energy, and are compared with the ones obtained by using only water as energy storage material. Interesting insights, relative to the estimation of the percentage of melted PCM at the end of the experimental test, are presented and discussed.

  1. Sector-wise midpoint characterization factors for impact assessment of regional consumptive and degradative water use.

    Science.gov (United States)

    Lin, Chia-Chun; Lin, Jia-Yu; Lee, Mengshan; Chiueh, Pei-Te

    2017-12-31

    Water availability, resulting from either a lack of water or poor water quality is a key factor contributing to regional water stress. This study proposes a set of sector-wise characterization factors (CFs), namely consumptive and degradative water stresses, to assess the impact of water withdrawals with a life cycle assessment approach. These CFs consider water availability, water quality, and competition for water between domestic, agricultural and industrial sectors and ecosystem at the watershed level. CFs were applied to a case study of regional water management of industrial water withdrawals in Taiwan to show that both regional or seasonal decrease in water availability contributes to a high consumptive water stress, whereas water scarcity due to degraded water quality not meeting sector standards has little influence on increased degradative water stress. Degradative water stress was observed more in the agricultural sector than in the industrial sector, which implies that the agriculture sector may have water quality concerns. Reducing water intensity and alleviating regional scale water stresses of watersheds are suggested as approaches to decrease the impact of both consumptive and degradative water use. The results from this study may enable a more detailed sector-wise analysis of water stress and influence water resource management policies. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Direct measurement of electron beam quality conversion factors using water calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, James, E-mail: james.renaud@mail.mcgill.ca; Seuntjens, Jan [Medical Physics Unit, McGill University, Montréal, Québec H3G 1A4 (Canada); Sarfehnia, Arman [Medical Physics Unit, McGill University, Montréal, Québec H3G 1A4, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 3E2 (Canada); Marchant, Kristin [Allan Blair Cancer Centre, Saskatchewan Cancer Agency, Regina, Saskatchewan S4T 7T1, Canada and Department of Oncology, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A1 (Canada); McEwen, Malcolm; Ross, Carl [Ionizing Radiation Standards, National Research Council of Canada, Ottawa, Ontario K1A 0R6 (Canada)

    2015-11-15

    Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol

  3. Chapter 4. Radioactivity of waters and factors influencing its value

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with radioactivity of waters and factors influencing its value. Chapter consists of next parts: (1) Natural radioactivity of hydrosphere; (2) Radioactive contamination of hydrosphere

  4. Modulation of tumor necrosis factor {alpha} expression in mouse brain after exposure to aluminum in drinking water

    Energy Technology Data Exchange (ETDEWEB)

    Tsunoda, M.; Sharma, R.P. [Georgia Univ., Athens (Greece). College of Veterinary Medicine

    1999-11-01

    Aluminum, a known neurotoxic substance and a ground-water pollutant, is a possible contributing factor in various nervous disorders including Alzheimer's disease. It has been hypothesized that cytokines are involved in aluminum neurotoxicity. We investigated the alterations in mRNA expression of tumor necrosis factor {alpha} (TNF{alpha}), interleukin-1{beta} (IL-1{beta}), and interferon {gamma} (IFN{gamma}), cytokines related to neuronal damage, in cerebrum and peripheral immune cells of mice after exposure to aluminum through drinking water. Groups of male BALB/c mice were administered aluminum ammonium sulfate in drinking water ad libitum at 0, 5, 25, and 125 ppm aluminum for 1 month. An additional group received 250 ppm ammonium as ammonium sulfate. After treatment, the cerebrum, splenic macrophages and lymphocytes were collected. The expression of TNF{alpha} mRNA in cerebrum was significantly increased among aluminum-treated groups compared with the control, in a dose-dependent manner. Other cytokines did not show any aluminum-related effects. In peripheral cells, there were no significant differences of cytokine mRNA expressions among treatment groups. Increased expression of TNF{alpha} mRNA by aluminum in cerebrum may reflect activation of microglia, a major source of TNF{alpha} in this brain region. Because the aluminum-induced alteration in cytokine message occurred at aluminum concentrations similar to those noted in contaminated water, these results may be relevant in considering the risk of aluminum neurotoxicity in drinking water. (orig.)

  5. Some factors including radiation affecting the productivity of proteinase enzymes by mucor lamprosporus

    International Nuclear Information System (INIS)

    El-Kabbany, H.M.I.

    1996-01-01

    In the present time, great attention has been focused on the production of milk clotting enzymes from microbial source for use as remain substitute due to the increasing demands on rennin for cheese making and the prohibition of the slaughter of small calves. The present investigation included the isolation and identification of remin-like enzyme fungal producers from different egyptian food and soil samples. Different factors including gamma radiation affecting the capability of selected isolate to produce the enzyme was also included. Special attention has also given to study the effect of different purification methods of the produced enzyme. The properties of the purified enzyme were also investigated

  6. Factors Affecting the Ability of Agriculture to Pay Irrigation-Water Costs

    Energy Technology Data Exchange (ETDEWEB)

    Hagood, M. A. [Land and Water Development Division, Food and Agriculture Organization of the United Nations, Rome (Italy)

    1967-11-15

    There are no universally acceptable standard criteria for determining how much agriculture can pay for irrigation water. Justification of cost will depend upon the country's need to develop its soil and water resources for food, for international trade, and for its cumulative effect on other industries in comparison with other possible uses and their over-all contributions to the economy. Social and political conditions often have as much or more influence on development cost decisions than do strictly economic analyses. Many studies indicate that US $0.10/1000 US gal is an upper limit of acceptable costs for developing irrigation water at present economic levels. Under private development and on projects where water users must pay total water costs, methods are available for making feasibility budgets based on present prices. Because of inflation, world food shortage, recessions, future population and other unknown factors, it is hazardous to predict how much farmers or agriculture can pay for irrigation water. Better utilization of water available now offers opportunities for ''developing'' sources at costs much less than those for sources such as sea-water conversion. (author)

  7. Optimizing fish and stream-water mercury metrics for calculation of fish bioaccumulation factors

    Science.gov (United States)

    Paul Bradley; Karen Riva Murray; Barbara C. Scudder Elkenberry; Christopher D. Knightes; Celeste A. Journey; Mark A. Brigham

    2016-01-01

    Mercury (Hg) bioaccumulation factors (BAFs; ratios of Hg in fish [Hgfish] and water[Hgwater]) are used to develop Total Maximum Daily Load and water quality criteria for Hg-impaired waters. Protection of wildlife and human health depends directly on the accuracy of site-specific estimates of Hgfish and Hgwater and the predictability of the relation between these...

  8. Water as a factor of differentiation in the food industry

    Directory of Open Access Journals (Sweden)

    Gianluca Nardone

    2010-09-01

    Full Text Available To foster their competitive advantage, food firms pay an increasing attention to strategies that tend to distinguish their products from the one supplied by their competitors, dedicating to this task most of their resources, knowledge and creativity. In such a framework, also the resource “water”, often seen as an homogenous product, is more and more utilized in the advertisement as an element that increase the quality of the final good. This paper aims to build a model that can explain the observed behavior in the different food industries and that can give some insights about the future perspectives of the utilization of the water as a differentiation factor. To reach this goal, first we present a survey of the commercials of specific food industries (beverages, pasta, bread, fresh produce in which it is shown the contribute of water on the product. On the base of the empirical evidence, we argue that the propensity to use the water as an element of differentiation is greater when greater are the degree of technological knowledge, the consumers’ perceptions, and the importance of the differentiation strategy in that specific industry. Since we expect that these three factors will increase over time, we also conclude that it is rational to experiment a generalized increase of the utilization of the water in the commercials of the food products. We also recommend to extend the analysis testing the results using a quantitative approach.

  9. Water as a factor of differentiation in the food industry

    Directory of Open Access Journals (Sweden)

    Gianluca Nardone

    2006-07-01

    Full Text Available To foster their competitive advantage, food firms pay an increasing attention to strategies that tend to distinguish their products from the one supplied by their competitors, dedicating to this task most of their resources, knowledge and creativity. In such a framework, also the resource “water”, often seen as an homogenous product, is more and more utilized in the advertisement as an element that increase the quality of the final good. This paper aims to build a model that can explain the observed behavior in the different food industries and that can give some insights about the future perspectives of the utilization of the water as a differentiation factor. To reach this goal, first we present a survey of the commercials of specific food industries (beverages, pasta, bread, fresh produce in which it is shown the contribute of water on the product. On the base of the empirical evidence, we argue that the propensity to use the water as an element of differentiation is greater when greater are the degree of technological knowledge, the consumers’ perceptions, and the importance of the differentiation strategy in that specific industry. Since we expect that these three factors will increase over time, we also conclude that it is rational to experiment a generalized increase of the utilization of the water in the commercials of the food products. We also recommend to extend the analysis testing the results using a quantitative approach.

  10. A Hydrological Concept including Lateral Water Flow Compatible with the Biogeochemical Model ForSAFE

    Directory of Open Access Journals (Sweden)

    Giuliana Zanchi

    2016-03-01

    Full Text Available The study presents a hydrology concept developed to include lateral water flow in the biogeochemical model ForSAFE. The hydrology concept was evaluated against data collected at Svartberget in the Vindeln Research Forest in Northern Sweden. The results show that the new concept allows simulation of a saturated and an unsaturated zone in the soil as well as water flow that reaches the stream comparable to measurements. The most relevant differences compared to streamflow measurements are that the model simulates a higher base flow in winter and lower flow peaks after snowmelt. These differences are mainly caused by the assumptions made to regulate the percolation at the bottom of the simulated soil columns. The capability for simulating lateral flows and a saturated zone in ForSAFE can greatly improve the simulation of chemical exchange in the soil and export of elements from the soil to watercourses. Such a model can help improve the understanding of how environmental changes in the forest landscape will influence chemical loads to surface waters.

  11. Effect of natural and man-made factors on mineral composition of Ardon river water

    International Nuclear Information System (INIS)

    Tyutikov, S.F.; Ermakov, V.V.; Degtyarev, A.P.; Krechetova, E.V.; Petrunina, N.S.

    2008-01-01

    The data on change of landscapes and biota (plants, algae, amphibious) are submitted as a result of natural catastrophes (mud-stream) and man-made factors (construction of a gas main and hydroelectric power station). It is shown, that the specified factors in some cases change not only structure of landscapes and a chemical compound of natural and industrial waters, but also a character of invasion of organisms. The certain influence of size of suspended matter of Ardon river waters on their general mineralization was discovered. Contents of heavy metals in waters of Ardon river is not critical and is in acceptable hygienic parameters.

  12. Separation factor dependence upon cathode material for tritium separation from heavy water by electrolysis

    International Nuclear Information System (INIS)

    Ogata, Y.; Sakuma, Y.; Ohtani, N.; Kotaka, M.

    2002-01-01

    Using three cathode materials, i.e. carbon (C), stainless steel (SUS), and nickel (Ni), tritium was separated from heavy water by electrolysis, and the separation factors were compared. To separate hydrogen isotopes, heavy water was electrolyzed by an electrolysis device with a solid polymer electrode (SPE), which needed no electrolyte additives for electrolysis. The anode was made of 3 mm thickness of a sintered porous titanium plate covered with iridium oxide. The cathode was made of the same thickness of a sintered porous carbon, stainless steel, or nickel plate. Heavy water or light water spiked with tritiated water was electrolyzed 20 A x 60 min with the electrolysis cell temperature at 10, 20 or 30degC, and 15 A x 80 min at 5degC. The produced hydrogen and oxygen gases were recombined using a palladium catalyst with nitrogen gas as a carrier. The activities of the water in the electrolysis cell and of the recombined water were analyzed using a liquid scintillation counter. The apparent D-T separation factor (SF D/T ) and H-T separation factor (SF H/T ) were calculated as quotient the specific activity of the water in the cell divided by that of the recombined water. The electrolysis potential to keep the current 20 A was 2-3 V. The average yields of the recombined water were 95%. At the cell temperature of 20degC, SF D/T (C), SF D/T (SUS), and SF D/T (Ni) were 2.42, 2.17, and 2.05, respectively. At the same temperature, SF H/T (C), SF H/T (SUS), and SF H/T (Ni) were 12.5, 10.8, and 11.8, respectively. The SFs were in agreement with the results in other works. The SFs were changed with the cell temperature. (author)

  13. Governance Regime Factors Conducive to Innovation Uptake in Urban Water Management: Experiences from Europe

    Directory of Open Access Journals (Sweden)

    Josselin Rouillard

    2016-10-01

    Full Text Available Innovative ways to manage the urban water cycle are required to deal with an ageing drinking and waste water infrastructure and new societal imperatives. This paper examines the influence of water governance in enabling transformations and technological innovation uptake in urban water management. A governance assessment framework is developed and applied in three case-studies, examining different scales and types of innovations used to tackle challenges in European urban water management. The methodology combines documentary analysis and interviews to reconstruct historical storylines of the shift in the water governance of urban water management for each site. The research provides detailed empirical observations on the factors conducive to innovation uptake at the local level. Critical governance factors such as commitment to compromise, the necessity to build political support, and the role of “entrepreneurs” and coalitions are highlighted. The paper also explores the role of discursive strategies and partnership design, as well as that of regulative, economic and communicative instruments, in creating barriers and opportunities to initiate and secure change. A number of recommendations targeted at innovators and water managers are presented in the conclusion.

  14. Plant nuclear factor Y (NF-Y) B subunits confer drought tolerance and lead to improved corn yields on water-limited acres.

    Science.gov (United States)

    Nelson, Donald E; Repetti, Peter P; Adams, Tom R; Creelman, Robert A; Wu, Jingrui; Warner, David C; Anstrom, Don C; Bensen, Robert J; Castiglioni, Paolo P; Donnarummo, Meghan G; Hinchey, Brendan S; Kumimoto, Roderick W; Maszle, Don R; Canales, Roger D; Krolikowski, Katherine A; Dotson, Stanton B; Gutterson, Neal; Ratcliffe, Oliver J; Heard, Jacqueline E

    2007-10-16

    Commercially improved crop performance under drought conditions has been challenging because of the complexity of the trait and the multitude of factors that influence yield. Here we report the results of a functional genomics approach that identified a transcription factor from the nuclear factor Y (NF-Y) family, AtNF-YB1, which acts through a previously undescribed mechanism to confer improved performance in Arabidopsis under drought conditions. An orthologous maize transcription factor, ZmNF-YB2, is shown to have an equivalent activity. Under water-limited conditions, transgenic maize plants with increased ZmNF-YB2 expression show tolerance to drought based on the responses of a number of stress-related parameters, including chlorophyll content, stomatal conductance, leaf temperature, reduced wilting, and maintenance of photosynthesis. These stress adaptations contribute to a grain yield advantage to maize under water-limited environments. The application of this technology has the potential to significantly impact maize production systems that experience drought.

  15. Factors determining water treatment behavior for the prevention of cholera in Chad.

    Science.gov (United States)

    Lilje, Jonathan; Kessely, Hamit; Mosler, Hans-Joachim

    2015-07-01

    Cholera is a well-known and feared disease in developing countries, and is linked to high rates of morbidity and mortality. Contaminated drinking water and the lack of sufficient treatment are two of the key causes of high transmission rates. This article presents a representative health survey performed in Chad to inform future intervention strategies in the prevention and control of cholera. To identify critical psychological factors for behavior change, structured household interviews were administered to N = 1,017 primary caregivers, assessing their thoughts and attitudes toward household water treatment according to the Risk, Attitude, Norm, Ability, and Self-regulation model. The intervention potential for each factor was estimated by analyzing differences in means between groups of current performers and nonperformers of water treatment. Personal risk evaluation for diarrheal diseases and particularly for cholera was very low among the study population. Likewise, the perception of social norms was found to be rather unfavorable for water treatment behaviors. In addition, self-reported ability estimates (self-efficacy) revealed some potential for intervention. A mass radio campaign is proposed, using information and normative behavior change techniques, in combination with community meetings focused on targeting abilities and personal commitment to water treatment. © The American Society of Tropical Medicine and Hygiene.

  16. Capacity factor analysis for evaluating water and sanitation infrastructure choices for developing communities.

    Science.gov (United States)

    Bouabid, Ali; Louis, Garrick E

    2015-09-15

    40% of the world's population lacks access to adequate supplies of water and sanitation services to sustain human health. In fact, more than 780 million people lack access to safe water supplies and about 2.5 billion people lack access to basic sanitation. Appropriate technology for water supply and sanitation (Watsan) systems is critical for sustained access to these services. Current approaches for the selection of Watsan technologies in developing communities have a high failure rate. It is estimated that 30%-60% of Watsan installed infrastructures in developing countries are not operating. Inappropriate technology is a common explanation for the high rate of failure of Watsan infrastructure, particularly in lower-income communities (Palaniappan et al., 2008). This paper presents the capacity factor analysis (CFA) model, for the assessment of a community's capacity to manage and sustain access to water supply and sanitation services. The CFA model is used for the assessment of a community's capacity to operate, and maintain a municipal sanitation service (MSS) such as, drinking water supply, wastewater and sewage treatment, and management of solid waste. The assessment of the community's capacity is based on seven capacity factors that have been identified as playing a key role in the sustainability of municipal sanitation services in developing communities (Louis, 2002). These capacity factors and their constituents are defined for each municipal sanitation service. Benchmarks and international standards for the constituents of the CFs are used to assess the capacity factors. The assessment of the community's capacity factors leads to determine the overall community capacity level (CCL) to manage a MSS. The CCL can then be used to assist the community in the selection of appropriate Watsan technologies for their MSS needs. The selection is done from Watsan technologies that require a capacity level to operate them that matches the assessed CCL of the

  17. Radioactivity and natural radionuclides distribution in river water, coastal water, sediment and Eichornia Crassipes (Mart) solms and their accumulation factor at Surabaya area

    International Nuclear Information System (INIS)

    Agus Taftazani; Sumining; Muzakky

    2002-01-01

    Distributions of radioactivity and natural radionuclides in water, sediment and eichornia crassipes (mart) solms from Surabaya River and coastal area have been evaluated. Five sampling locations were selected to represent fresh water and coastal water environment. The samples consist of water (fresh & coastal), bottom surface sediment and eichornia crassipes (mart) solms. The result showed that the gross-β activity from water environment were lower than the threshold value of Environmental Minister Act. Kep.02/MENKLH/I/1988 (1000 mBq/L) and indicated that β-radio ecological quality of water were still good. But the activity of the gross-α of water environment were higher than the threshold value of Environmental Minister Act. Kep.02/MENKLH/I/1988 (100 mBq/L). The eichornia crassipes (mart) solms (gross) activity were higher than water and sediment activities and indicated that transfer of radio nuclides from water to sediment and organism can be detected in water environment. Two natural radionuclide can be identified by γ-Spectrometric technique, they were K"4"0 and Tl"2"0"8. Generally the distribution factors F_D were smaller than bioaccumulation factor F_B. (author)

  18. Factors influencing farmers’ willingness to participate in water allocation trading. A case study in southern Spain

    Directory of Open Access Journals (Sweden)

    Giacomo Giannoccaro

    2016-03-01

    Full Text Available This study aims to uncover the factors that influence farmers’ attitudes towards water allocation trading. In the study, we simulate two water availability scenarios, an average year and a drought year, in a contingent valuation experiment with 241 farmers. A survey was held in the spring of 2012 in the Guadalquivir and Almanzora River Basins. First, we estimated a multinomial logit model to determine the factors that influence farmers to decide to participate in our hypothetical market. We then analysed the structural and socio-economic factors determining the monetary value of traded water using Heckman’s two-step model. Our results indicate that those farmers who are more innovative and have had agricultural training show a higher willingness to participate in water trading. Additionally, low water-supply guarantee and appropriate information about seasonal water availability increase the probability of participation. Higher willingness to pay (WTP for water is found in horticulture and among farmers who grow citrus and other permanent crops; lower water selling value (WTA is found in farms with extensive annual crops and traditional olive groves. However, monetary values (WTP/WTA are strongly dependent on the current cost of irrigation water services. While findings of this research seem to support the idea of diffusion innovation theory, the existence of ethical concerns that might influence farmers’ acceptance of irrigation water markets needs further analysis.

  19. Factors influencing farmers’ willingness to participate in water allocation trading. A case study in southern Spain

    Energy Technology Data Exchange (ETDEWEB)

    Giannoccaro, G.; Castillo, M.; Berbel, J.

    2016-11-01

    This study aims to uncover the factors that influence farmers’ attitudes towards water allocation trading. In the study, we simulate two water availability scenarios, an average year and a drought year, in a contingent valuation experiment with 241 farmers. A survey was held in the spring of 2012 in the Guadalquivir and Almanzora River Basins. First, we estimated a multinomial logit model to determine the factors that influence farmers to decide to participate in our hypothetical market. We then analysed the structural and socio-economic factors determining the monetary value of traded water using Heckman’s two-step model. Our results indicate that those farmers who are more innovative and have had agricultural training show a higher willingness to participate in water trading. Additionally, low water-supply guarantee and appropriate information about seasonal water availability increase the probability of participation. Higher willingness to pay (WTP) for water is found in horticulture and among farmers who grow citrus and other permanent crops; lower water selling value (WTA) is found in farms with extensive annual crops and traditional olive groves. However, monetary values (WTP/WTA) are strongly dependent on the current cost of irrigation water services. While findings of this research seem to support the idea of diffusion innovation theory, the existence of ethical concerns that might influence farmers’ acceptance of irrigation water markets needs further analysis. (Author)

  20. Geographical distribution patterns of iodine in drinking-water and its associations with geological factors in Shandong Province, China.

    Science.gov (United States)

    Gao, Jie; Zhang, Zhijie; Hu, Yi; Bian, Jianchao; Jiang, Wen; Wang, Xiaoming; Sun, Liqian; Jiang, Qingwu

    2014-05-19

    County-based spatial distribution characteristics and the related geological factors for iodine in drinking-water were studied in Shandong Province (China). Spatial autocorrelation analysis and spatial scan statistic were applied to analyze the spatial characteristics. Generalized linear models (GLMs) and geographically weighted regression (GWR) studies were conducted to explore the relationship between water iodine level and its related geological factors. The spatial distribution of iodine in drinking-water was significantly heterogeneous in Shandong Province (Moran's I = 0.52, Z = 7.4, p water were identified in the south-western and north-western parts of Shandong Province by the purely spatial scan statistic approach. Both GLMs and GWR indicated a significantly global association between iodine in drinking-water and geological factors. Furthermore, GWR showed obviously spatial variability across the study region. Soil type and distance to Yellow River were statistically significant at most areas of Shandong Province, confirming the hypothesis that the Yellow River causes iodine deposits in Shandong Province. Our results suggested that the more effective regional monitoring plan and water improvement strategies should be strengthened targeting at the cluster areas based on the characteristics of geological factors and the spatial variability of local relationships between iodine in drinking-water and geological factors.

  1. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    Science.gov (United States)

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  2. Deriving Scaling Factors Using a Global Hydrological Model to Restore GRACE Total Water Storage Changes for China's Yangtze River Basin

    Science.gov (United States)

    Long, Di; Yang, Yuting; Yoshihide, Wada; Hong, Yang; Liang, Wei; Chen, Yaning; Yong, Bin; Hou, Aizhong; Wei, Jiangfeng; Chen, Lu

    2015-01-01

    This study used a global hydrological model (GHM), PCR-GLOBWB, which simulates surface water storage changes, natural and human induced groundwater storage changes, and the interactions between surface water and subsurface water, to generate scaling factors by mimicking low-pass filtering of GRACE signals. Signal losses in GRACE data were subsequently restored by the scaling factors from PCR-GLOBWB. Results indicate greater spatial heterogeneity in scaling factor from PCR-GLOBWB and CLM4.0 than that from GLDAS-1 Noah due to comprehensive simulation of surface and subsurface water storage changes for PCR-GLOBWB and CLM4.0. Filtered GRACE total water storage (TWS) changes applied with PCR-GLOBWB scaling factors show closer agreement with water budget estimates of TWS changes than those with scaling factors from other land surface models (LSMs) in China's Yangtze River basin. Results of this study develop a further understanding of the behavior of scaling factors from different LSMs or GHMs over hydrologically complex basins, and could be valuable in providing more accurate TWS changes for hydrological applications (e.g., monitoring drought and groundwater storage depletion) over regions where human-induced interactions between surface water and subsurface water are intensive.

  3. Factors affecting domestic water consumption in rural households upon access to improved water supply: insights from the Wei River Basin, China.

    Science.gov (United States)

    Fan, Liangxin; Liu, Guobin; Wang, Fei; Geissen, Violette; Ritsema, Coen J

    2013-01-01

    Comprehensively understanding water consumption behavior is necessary to design efficient and effective water use strategies. Despite global efforts to identify the factors that affect domestic water consumption, those related to domestic water use in rural regions have not been sufficiently studied, particularly in villages that have gained access to improved water supply. To address this gap, we investigated 247 households in eight villages in the Wei River Basin where three types of improved water supply systems are implemented. Results show that domestic water consumption in liters per capita per day was significantly correlated with water supply pattern and vegetable garden area, and significantly negatively correlated with family size and age of household head. Traditional hygiene habits, use of water appliances, and preference for vegetable gardening remain dominant behaviors in the villages with access to improved water supply. Future studies on rural domestic water consumption should pay more attention to user lifestyles (water appliance usage habits, outdoor water use) and cultural backgrounds (age, education).

  4. Factors affecting domestic water consumption in rural households upon access to improved water supply: insights from the Wei River Basin, China.

    Directory of Open Access Journals (Sweden)

    Liangxin Fan

    Full Text Available Comprehensively understanding water consumption behavior is necessary to design efficient and effective water use strategies. Despite global efforts to identify the factors that affect domestic water consumption, those related to domestic water use in rural regions have not been sufficiently studied, particularly in villages that have gained access to improved water supply. To address this gap, we investigated 247 households in eight villages in the Wei River Basin where three types of improved water supply systems are implemented. Results show that domestic water consumption in liters per capita per day was significantly correlated with water supply pattern and vegetable garden area, and significantly negatively correlated with family size and age of household head. Traditional hygiene habits, use of water appliances, and preference for vegetable gardening remain dominant behaviors in the villages with access to improved water supply. Future studies on rural domestic water consumption should pay more attention to user lifestyles (water appliance usage habits, outdoor water use and cultural backgrounds (age, education.

  5. Radioactivity and Natural Radio nuclides Distribution in River Water, Coastal Water, Sediment and Eichornia Crassipes (Mart) Sloms and Their Accumulation Factor at Surabaya Area

    International Nuclear Information System (INIS)

    Agus Taftazani; Sumining; Muzakky

    2002-01-01

    Distribution of radioactivity and natural radionuclide in water, sediment and eichornia crassipes (mart) sloms from Surabaya river and coastal area have been evaluated. Five sampling locations were selected to represent fresh water and coastal water environment. The samples consist of water (fresh and coastal), bottom surface sediment and eichornia crassipes (mart) sloms The result showed that the gross-β activity from water environment were lower than the threshold value of Environmental Minister Act. Kep.02/MENKLH/I/1988 (1000 mBq/L) and indicated that β-radioecological quality of water were still good. But the activity of the gross-α of water environment were higher than the threshold value of Environmental Minister Act. Kep.02/MENKLH/I/1988 (100 mBq/L). The eichornia crassipes (mart) sloms (gross) activity were higher than water and sediment activities and indicated that transfer of radionuclides from water to sediment and organism can be detected in water environment. Two natural radionuclides can be identified by γ-Spectrometric technique, they were K-40 and TI-208. Generally the distribution factor F D were smaller than bioaccumulation factor F B . (author)

  6. Farmer perceptions on factors influencing water scarcity for goats in resource-limited communal farming environments.

    Science.gov (United States)

    Mdletshe, Zwelethu Mfanafuthi; Ndlela, Sithembile Zenith; Nsahlai, Ignatius Verla; Chimonyo, Michael

    2018-05-09

    The objective of the study was to compare factors influencing water scarcity for goats in areas where there are seasonal and perennial rivers under resource-limited communal farming environments. Data were collected using a structured questionnaire (n = 285) administered randomly to smallholder goat farmers from areas with seasonal and perennial rivers. Ceremonies was ranked as the major reason for keeping goats. Water scarcity was ranked the major constraint to goat production in areas with seasonal rivers when compared to areas with perennial rivers (P goat drinking in areas with seasonal and perennial river systems during cool dry and rainy seasons. Rivers were ranked as an important water source for goat drinking where there are seasonal and perennial river systems during the cool dry season. Households located close (≤ 3 km) to the nearest water source reported drinking water for goats a scarce resource. These results show that river systems, season and distance to the nearest water source from a household were factors perceived by farmers to influence water scarcity for goats in resource-limited communal farming environments. Farmers should explore water-saving strategies such as recycling wastewater from kitchens and bathrooms as an alternative water source. The government may assist farmers through sinking boreholes to supply water for both humans and livestock.

  7. PRIMARILY RESULTS OF PHYTOPLANKTON DNA AND VARIATION TO ENVIRONMENTAL FACTORS IN DURRES`S BAY COASTAL WATERS (ALBANIA

    Directory of Open Access Journals (Sweden)

    Laura Gjyli

    2013-10-01

    Full Text Available After isolation of phytoplankton DNA in coastal waters of Durres Bay, Albania, quantification and analysis of quality were investigated with spectrophotometric analysis. Analysis of UV absorption by the nucleotides provides a simple and accurate estimation of the concentration of nucleic acids in a sample. This method is however limited by the quantity of DNA and the purity of the preparation. Also biotic environment factors as Chlorophyll a and abiotic environment factors as temperature, salinity, pH, dissolved oxygen, turbidity, nitrate, phosphate were investigated to assess DNA quantities in different environment conditions. The Chlorophyll a was studied also to access the level of trophy. The sample stations were: Golem Beach (GB, Channel of Plepa (ChP, Hekurudha Beach (HB, Ex-Fuel Quay in Marine Durres Harbour (EFQ, Water Channel of Durres City (WChDC and Currila Beach (CB. Samples are taken in one meter depth from the water surface. Water samples were collected monthly from April to October 2011. The most abundant stations with phytoplankton DNA are Channel of Plepa and Water Channel of Durres City. This confirms that there are spills of fresh waters, sewage or agricultural water spills, often discharge in coastal waters. Referring Mutliple Regression Analysis and single regression analysis, the association between phytoplankton DNA and environment factors was strong (R2 = 0.75. Basing in single correlation and statistically significance (p-value ≤ 0.05, the enviroment factors that correlated to phytoplankton DNA were pH, salinity and phosphate; explaining thus the variation of total phytoplankton in Durres Bay coastal waters.

  8. Lake Chini Water Quality Assessment Using Multivariate Approach

    International Nuclear Information System (INIS)

    Ahmad, A.K.; Shuhaimi, Othman M.; Lim, E.C.; Aziz, Z.A.

    2013-01-01

    An analysis was undertaken using the multivariate approach to determine the important water quality for shallow lake water quality assessment. Fourteen water quality parameters which includes biological, physical and chemical components were collected monthly over twelve month period. The data were analysed using factor analysis which involves identification of factor correlation, factor extraction and factor permutations. The first process involved the clustering of high correlation parameters into its respective factor and the removal of parameters that have more than one factor. Agglomerative hierarchy (HACA) and discriminant analysis (DA) were also used to exhibit the important factors that has significant influence on lake water quality. The analysis showed that Lake Chini water quality was determined by more than one factor. The results indicated that the biological and chemical (nutrients) components have significant influence in determining the lake water quality. The biological parameters namely BOD5, COD, chlorophyll a and chemical (nitrate and orthophosphate) are important parameters in Lake Chini. All analysis demonstrated the importance of biological and chemical water quality components in the determination of Lake Chini water quality. (author)

  9. Determination of water environment standards based on water quality criteria in China: Limitations and feasibilities.

    Science.gov (United States)

    Wang, Tieyu; Zhou, Yunqiao; Bi, Cencen; Lu, Yonglong; He, Guizhen; Giesy, John P

    2017-07-01

    There is a need to formulate water environment standards (WESs) from the current water quality criteria (WQC) in China. To this end, we briefly summarize typical mechanisms applied in several countries with longer histories of developing WESs, and three limitations to formulating WESs in China were identified. After analyzing the feasibility factors including economic development, scientific support capability and environmental policies, we realized that China is still not ready for a complete change from its current nation-wide unified WES system to a local-standard-based system. Thus, we proposed a framework for transformation from WQC to WESs in China. The framework consists of three parts, including responsibilities, processes and policies. The responsibilities include research authorization, development of guidelines, and collection of information, at both national and local levels; the processes include four steps and an impact factor system to establish water quality standards; and the policies include seven specific proposals. Copyright © 2016. Published by Elsevier B.V.

  10. Nationwide rural well water survey, the quality of household water and factors influencing it

    International Nuclear Information System (INIS)

    Korkka-Niemi, K.; Sipilae, A.; Hatva, T.; Hiisvirta, L.; Lahti, K.; Alfthan, G.

    1993-01-01

    The quality of water in 1 421 drinking—water wells was monitored in a nationwide well water study. Samples were taken once from all wells, and during three seasons from 421 wells. The wells were selected in such a way that the sample would be as representative as possible of the quality of the drinking—water in households’ own wells in ru— ral areas. The study comprised general water quality parameters, influence of sampling season, and factors related to the type, the condition and the pollution of the wells. In part of the well waters selenium, radioactivity and pesticides were determined. The effect of plumbing materials on the quality of water was also examined. The health—based criteria of the quality of drinking—water were not met in 50 — 70 % of the well waters monitored, depending upon the sampling time. The most common defects were the occurrence of bacteria indicating faecal pollution (2— 25 %) and a high concentration of nitrate (11 — 13 %) and fluoride (7 — 16 %). The tar— get values set for the other properties affecting the usableness of water were not met in 80 % of the well waters examined. The most common defects in this respect were the turbidity and the colour of water (40 — 50 %), the occurrence of iron (20 — 25 %) and manganese (20 %), and a low ph value. Depending upon the area, only 11 — 15 % of the wells met all the criteria related to the corrosive effect of the water. About 17 % of the households in the study suffered from periodical or continuous insufficiency of water. The types of well were dug wells with concrete sink rings in 72 %, and drilled bedrock wells in 20 % of te cases. The rest were spring wells or dug wells with stone walls. The condition of a well was, according 10 the judgement of the sampler, good in 58 %, satisfactory in 36 % and poor in 6 % of the households. Seasonal variation could be seen mainly in the occurrence of faecal bacteria. Distinct differences in the quality of water appeared

  11. Correction factors and performance of a 4 degrees C sealed water calorimeter.

    Science.gov (United States)

    Seuntjens, J; Palmans, H

    1999-03-01

    In the past two decades, the water calorimetry technique for determination of absorbed dose to water in several types of radiation beams has moved significantly closer to being a recognized method. In this paper we summarize the constructional details of a 4 degrees C sealed water calorimeter currently in operation at the University of Gent. This sealed water (SW) calorimeter is of the Domen type and has been improved in several aspects compared with its original design. The relevant correction factors for heat transport and for field perturbation are described. Using relative response measurements in 60Co, we experimentally verified the relative heat defect for two distinct chemical systems, using two different detection vessel arrangements. The overall 1sigma uncertainty on the absorbed dose to water at 60Co based on this system amounts to 0.7%.

  12. Change of water consumption and its potential influential factors in Shanghai: A cross-sectional study

    Science.gov (United States)

    2012-01-01

    Background Different water choices affect access to drinking water with different quality. Previous studies suggested social-economic status may affect the choice of domestic drinking water. The aim of this study is to investigate whether recent social economic changes in China affect residents’ drinking water choices. Methods We conducted a cross-sectional survey to investigate residents’ water consumption behaviour in 2011. Gender, age, education, personal income, housing condition, risk perception and personal preference of a certain type of water were selected as potential influential factors. Univariate and backward stepwise logistic regression analyses were performed to analyse the relation between these factors and different drinking water choices. Basic information was compared with that of a historical survey in the same place in 2001. Self-reported drinking-water-related diarrhoea was found correlated with different water choices and water hygiene treatment using chi-square test. Results The percentage of tap water consumption remained relatively stable and a preferred choice, with 58.99% in 2001 and 58.25% in 2011. The percentage of bottled/barrelled water consumption was 36.86% in 2001 and decreased to 25.75% in 2011. That of household filtrated water was 4.15% in 2001 and increased to 16.00% in 2011. Logistic regression model showed strong correlation between one’s health belief and drinking water choices (P water-related diarrhoea was found in all types of water and improper water hygiene behaviours still existed among residents. Conclusions Personal health belief, housing condition, age, personal income, education, taste and if worm ever founded in tap water affected domestic drinking water choices in Shanghai. PMID:22708830

  13. Factors Affecting Water Dynamics and Their Assessment in Agricultural Landscapes

    International Nuclear Information System (INIS)

    Sakadevan, K.; Nguyen, M.L.

    2015-01-01

    The intensification and extension of agriculture have contributed significantly to the global food production in the last five decades. However, intensification without due attention to the ecosystem services and sustainability of soil and water resources contributed to land and water quality degradation such as soil erosion, decreased soil fertility and quality, salinization and nutrient discharge to surface and ground waters. Land use change from forests to crop lands altered the vegetation pattern and hydrology of landscapes with increased nutrient discharge from crop lands to riverine environment. Global climate change will increase the amount of water required for agriculture in addition to water needed for further irrigation development causing water scarcity in many dry, arid and semi-arid regions. The water and nutrient use efficiencies of agricultural production systems are still below 40% in many regions across the globe. Nitrogen (N) and phosphorus (P) fertilizer use in agriculture have accelerated the cycling of these nutrients in the landscape and contributed to water quality degradation. Such nutrient pollution has a wide array of consequences including eutrophication of inland waters and marine ecosystems. While intensifying drought conditions, increasing water consumption and environmental pollution in many parts of the world threatens agricultural productivity and livelihood, these also provided opportunities for farmers to use improved land and water management technologies and practices to make agriculture resilient to external shocks

  14. Factors shaping bacterial phylogenetic and functional diversity in coastal waters of the NW Mediterranean Sea

    Science.gov (United States)

    Boras, Julia A.; Vaqué, Dolors; Maynou, Francesc; Sà, Elisabet L.; Weinbauer, Markus G.; Sala, Maria Montserrat

    2015-03-01

    To evaluate the main factors shaping bacterioplankton phylogenetic and functional diversity in marine coastal waters, we carried out a two-year study based on a monthly sampling in Blanes Bay (NW Mediterranean). We expected the key factors driving bacterial diversity to be (1) temperature and nutrient concentration, together with chlorophyll a concentration as an indicator of phytoplankton biomass and, hence, a carbon source for bacteria (here called bottom-up factors), and (2) top-down pressure (virus- and protist-mediated mortality of bacteria). Phylogenetic diversity was analyzed by denaturing gradient gel electrophoresis (DGGE) of 16S rRNA. Functional diversity was assessed by using monomeric carbon sources in Biolog EcoPlates and by determining the activity of six extracellular enzymes. Our results indicate that the bacterial phylogenetic and functional diversity in this coastal system is shaped mainly by bottom-up factors. A dendrogram analysis of the DGGE banding patterns revealed three main sample clusters. Two clusters differed significantly in temperature, nitrate and chlorophyll a concentration, and the third was characterized by the highest losses of bacterial production due to viral lysis detected over the whole study period. Protistan grazing had no effect on bacterial functional diversity, since there were no correlations between protist-mediated mortality (PMM) and extracellular enzyme activities, and utilization of only two out of the 31 carbon sources (N-acetyl-D-glucosamine and α-cyclodextrin) was correlated with PMM. In contrast, virus-mediated mortality correlated with changes in the percentage of use of four carbon sources, and also with specific leu-aminopeptidase and β-glucosidase activity. This suggests that viral lysate provides a pool of labile carbon sources, presumably including amino acids and glucose, which may inhibit proteolytic and glucosidic activity. Our results indicate that bottom-up factors play a more important role than

  15. Incorporating green infrastructure into water resources management plans to address water quality impairments

    Science.gov (United States)

    Managers of urban watersheds with excessive nutrient loads are more frequently turning to green infrastructure (GI) to manage their water quality impairments. The effectiveness of GI is dependent on a number of factors, including (1) the type and placement of GI within the waters...

  16. Drinking water from dug wells in rural ghana--salmonella contamination, environmental factors, and genotypes.

    Science.gov (United States)

    Dekker, Denise Myriam; Krumkamp, Ralf; Sarpong, Nimako; Frickmann, Hagen; Boahen, Kennedy Gyau; Frimpong, Michael; Asare, Renate; Larbi, Richard; Hagen, Ralf Matthias; Poppert, Sven; Rabsch, Wolfgang; Marks, Florian; Adu-Sarkodie, Yaw; May, Jürgen

    2015-03-27

    Salmonellosis is an important but neglected disease in sub-Saharan Africa. Food or fecal-oral associated transmissions are the primary cause of infections, while the role of waterborne transmission is unclear. Samples were collected from different dug wells in a rural area of Ghana and analyzed for contamination with bacteria, and with Salmonella in particular. In addition, temporal dynamics and riks factors for contamination were investigated in 16 wells. For all Salmonella isolates antibiotic susceptibility testing was performed, serovars were determined and strains from the same well with the same serovar were genotyped. The frequency of well water contamination with Gram-negative rod-shaped bacteria was 99.2% (n = 395). Out of 398 samples, 26 (6.5%) tested positive for Salmonella spp. The serovar distribution was diverse including strains not commonly isolated from clinical samples. Resistance to locally applied antibiotics or resistance to fluoroquinolones was not seen in the Salmonella isolates. The risk of Salmonella contamination was lower in wells surrounded by a frame and higher during the rainy season. The study confirms the overall poor microbiological quality of well water in a resource-poor area of Ghana. Well contamination with Salmonella poses a potential threat of infection, thus highlighting the important role of drinking water safety in infectious disease control.

  17. Factors controlling physico-chemical characteristics in the coastal waters off Mangalore-A multivariate approach

    International Nuclear Information System (INIS)

    Shirodkar, P.V.; Mesquita, A.; Pradhan, U.K.; Verlekar, X.N.; Babu, M.T.; Vethamony, P.

    2009-01-01

    Water quality parameters (temperature, pH, salinity, DO, BOD, suspended solids, nutrients, PHc, phenols, trace metals-Pb, Cd and Hg, chlorophyll-a (chl-a) and phaeopigments) and the sediment quality parameters (total phosphorous, total nitrogen, organic carbon and trace metals) were analysed from samples collected at 15 stations along 3 transects off Karnataka coast (Mangalore harbour in the south to Suratkal in the north), west coast of India during 2007. The analyses showed high ammonia off Suratkal, high nitrite (NO 2 -N) and nitrate (NO 3 -N) in the nearshore waters off Kulai and high nitrite (NO 2 -N) and ammonia (NH 3 -N) in the harbour area. Similarly, high petroleum hydrocarbon (PHc) values were observed near the harbour, while phenols remained high in the nearshore waters of Kulai and Suratkal. Significantly, high concentrations of cadmium and mercury with respect to the earlier studies were observed off Kulai and harbour regions, respectively. R-mode varimax factor analyses were applied separately to surface and bottom water data sets due to existing stratification in the water column caused by riverine inflow and to sediment data. This helped to understand the interrelationships between the variables and to identify probable source components for explaining the environmental status of the area. Six factors (each for surface and bottom waters) were found responsible for variance (86.9% in surface and 82.4% in bottom) in the coastal waters between Mangalore and Suratkal. In sediments, 4 factors explained 86.8% of the observed total variance. The variances indicated addition of nutrients and suspended solids to the coastal waters due to weathering and riverine transport and are categorized as natural sources. The observed contamination of coastal waters indicated anthropogenic inputs of Cd and phenol from industrial effluent sources at Kulai and Suratkal, ammonia from wastewater discharges off Kulai and harbour, PHc and Hg from boat traffic and harbour

  18. Factors influencing the efficiency of radiation-induced degradation of water pollutants

    International Nuclear Information System (INIS)

    Getoff, Nikola

    2002-01-01

    The efficiency of the radiation-induced degradation of water pollutants depends on several factors, such as kind and energy of radiation, absorbed dose, dose rate, pollutant concentration as well as synergistic effects of radiation and ozone or/and catalysts (e.g. TiO 2 ) and of the molecular structure of the pollutants. The role of the individual factors is illustrated by examples. The application of pulse radiolysis in addition to chemical analysis for elucidation of reaction mechanisms and optimization of the degradation treatment is also mentioned

  19. Factors Affecting Chinese Farmers' Decisions to Adopt a Water-Saving Technology

    NARCIS (Netherlands)

    Herzfeld, T.; Glauben, T.; Zhang, Y.; Hu, B.

    2008-01-01

    Chinese farm households (N = 240) were interviewed to understand some of the factors affecting their adoption of a water-saving technology called the Ground Cover Rice Production System (GCRPS). A logit model was established on the basis of a survey to estimate the determinants of adoption and to

  20. The main factors of water pollution in Danube River basin

    Directory of Open Access Journals (Sweden)

    Carmen Gasparotti

    2014-05-01

    Full Text Available The paper proposed herewith aims to give an overview on the pollution along the Danube River. Water quality in Danube River basin (DRB is under a great pressure due to the diverse range of the human activities including large urban center, industrial, agriculture, transport and mining activities. The most important aspects of the water pollution are: organic, nutrient and microbial pollution, , hazardous substances, and hydro-morphological alteration. Analysis of the pressures on the Danube River showed that a large part of the Danube River is subject to multiple pressures and there are important risks for not reaching good ecological status and good chemical status of the water in the foreseeable future. In 2009, the evaluation based on the results of the Trans National Monitoring Network showed for the length of water bodies from the Danube River basin that 22% achieved good ecological status or ecological potential and 45% river water bodies achieved good chemical status. Another important issue is related to the policy of water pollution.

  1. Hazards of Healthy Living: Bottled Water and Salad Vegetables as Risk Factors for Campylobacter Infection

    Science.gov (United States)

    Ribeiro, C. Donald; Salmon, Roland L.

    2003-01-01

    Campylobacter is the most common cause of bacterial gastroenteritis worldwide, yet the etiology of this infection remains only partly explained. In a retrospective cohort study, we compared 213 sporadic campylobacter case-patients with 1,144 patients with negative fecal samples. Information was obtained on food history, animal contact, foreign travel, leisure activities, medical conditions, and medication use. Eating chicken, eating food from a fried chicken outlet, eating salad vegetables, drinking bottled water, and direct contact with cows or calves were all independently associated with infection. The population-attributable fractions for these risk factors explained nearly 70% of sporadic campylobacter infections. Eating chicken is a well-established risk factor, but consuming salad and bottled water are not. The association with salad may be explained by cross-contamination of food within the home, but the possibility that natural mineral water is a risk factor for campylobacter infection could have wide public health implications. PMID:14609455

  2. Macroenvironmental factors including GDP per capita and physical activity in Europe.

    Science.gov (United States)

    Cameron, Adrian J; Van Stralen, Maartje M; Kunst, Anton E; Te Velde, Saskia J; Van Lenthe, Frank J; Salmon, Jo; Brug, Johannes

    2013-02-01

    Socioeconomic inequalities in physical activity at the individual level are well reported. Whether inequalities in economic development and other macroenvironmental variables between countries are also related to physical activity at the country level is comparatively unstudied. We examined the relationship between country-level data on macroenvironmental factors (gross domestic product (GDP) per capita, public sector expenditure on health, percentage living in urban areas, and cars per 1000 population) with country-level physical activity prevalence obtained from previous pan-European studies. Studies that assessed leisuretime physical activity (n = 3 studies including 27 countries in adults, n = 2 studies including 28 countries in children) and total physical activity (n = 3 studies in adults including 16 countries) were analyzed separately as were studies among adults and children. Strong and consistent positive correlations were observed between country prevalence of leisure-time physical activity and country GDP per capita in adults (average r = 0.70; all studies, P G 0.05). In multivariate analysis, country prevalence of leisure-time physical activity among adults remained associated with country GDP per capita (two of three studies) but not urbanization or educational attainment. Among school-age populations, no association was found between country GDP per capita and country prevalence of leisure-time physical activity. In those studies that assessed total physical activity (which also includes occupational and transport physical activity), no association with country GDP per capita was observed. Clear differences in national leisure-time physical activity levels throughout Europe may be a consequence of economic development. Lack of economic development of some countries in Europe may make increasing leisure-time physical activity more difficult. Further examination of the link between country GDP per capita and national physical activity levels (across

  3. Mechanism of water inrush in tunnel construction in karst area

    Directory of Open Access Journals (Sweden)

    Liping Li

    2016-05-01

    Full Text Available With the rapid developing trend of long, large and deep construction characteristics for underground engineering in the world, China has the largest number of karst tunnels with the wide scales and great difficulties. As the hydrogeological conditions are becoming unprecedentedly complex, water inrush disaster becomes the bottleneck problem for the further development of traffic tunnels. Based on the statistical analysis of a large number of cases of water inrush in karst tunnels, influence factors of water inrush have been put forward from the view of karst hydrogeological factors and engineering disturbance of human factors. Karst hydrogeological factors include geological defect, strata dip, formation lithology, landform and underground level. Human factors of engineering disturbance include excavation and reinforcement geological prediction, monitoring and measurement of surrounding rock. It also introduces some geological disasters caused by the water inrush in tunnel excavation. In terms of the formation of water inrush channel, water inrush types are divided into geological defects inrush, non-geological defects inrush and the combination. Conclusions will be beneficial to further research on hazards control of underground construction.

  4. Changes in some coronary disease risk factors under influence of treatment with Swieradow radon waters

    Energy Technology Data Exchange (ETDEWEB)

    Szczeklik, E; Halawa, B; Kwiatkowski, J

    1977-01-01

    In 66 patients subbivided into group of patients with coronary disease and group of control subjects the effect of radioactive waterbath and climatotherapy in Swieradow upon coronary disease risk factors was studied. The following risk factors were taken into account: cholesterol level, triglicerides, LDL, uric acid, the serum glucose level, arterial tension and weight. The results obtained indicate that the therapy with radon waters of Swieradow complexed with climatotherapy decreases the content of some coronary disease risk factors. The decrease of the urin acid in the serum, the lowering of arterial tension and decrease of body weight was noted. The lipid level in the serum did not change under effect of radioactive waters.

  5. Design of a high-lift experiment in water including active flow control

    International Nuclear Information System (INIS)

    Beutel, T; Schwerter, M; Büttgenbach, S; Leester-Schädel, M; Sattler, S; El Sayed, Y; Radespiel, R; Zander, M; Sinapius, M; Wierach, P

    2014-01-01

    This paper describes the structural design of an active flow-control experiment. The aim of the experiment is to investigate the increase in efficiency of an internally blown Coanda flap using unsteady blowing. The system uses tailor-made microelectromechanical (MEMS) pressure sensors to determine the state of the oncoming flow and an actuated lip to regulate the mass flow and velocity of a stream near a wall over the internally blown flap. Sensors and actuators are integrated into a highly loaded system that is extremely compact. The sensors are connected to a bus system that feeds the data into a real-time control system. The piezoelectric actuators using the d 33 effect at a comparable low voltage of 120 V are integrated into a lip that controls the blowout slot height. The system is designed for closed-loop control that efficiently avoids flow separation on the Coanda flap. The setup is designed for water-tunnel experiments in order to reduce the free-stream velocity and the system’s control frequency by a factor of 10 compared with that in air. This paper outlines the function and verification of the system’s main components and their development. (technical note)

  6. Nationwide water availability data for energy-water modeling

    Energy Technology Data Exchange (ETDEWEB)

    Tidwell, Vincent Carroll [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zemlick, Katie M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    The purpose of this effort is to explore where the availability of water could be a limiting factor in the siting of new electric power generation. To support this analysis, water availability is mapped at the county level for the conterminous United States (3109 counties). Five water sources are individually considered, including unappropriated surface water, unappropriated groundwater, appropriated water (western U.S. only), municipal wastewater and brackish groundwater. Also mapped is projected growth in non-thermoelectric consumptive water demand to 2035. Finally, the water availability metrics are accompanied by estimated costs associated with utilizing that particular supply of water. Ultimately these data sets are being developed for use in the National Renewable Energy Laboratories' (NREL) Regional Energy Deployment System (ReEDS) model, designed to investigate the likely deployment of new energy installations in the U.S., subject to a number of constraints, particularly water.

  7. Estimating the risk of cyanobacterial occurrence using an index integrating meteorological factors: application to drinking water production.

    Science.gov (United States)

    Ndong, Mouhamed; Bird, David; Nguyen-Quang, Tri; de Boutray, Marie-Laure; Zamyadi, Arash; Vinçon-Leite, Brigitte; Lemaire, Bruno J; Prévost, Michèle; Dorner, Sarah

    2014-06-01

    The sudden appearance of toxic cyanobacteria (CB) blooms is still largely unpredictable in waters worldwide. Many post-hoc explanations for CB bloom occurrence relating to physical and biochemical conditions in lakes have been developed. As potentially toxic CB can accumulate in drinking water treatment plants and disrupt water treatment, there is a need for water treatment operators to determine whether conditions are favourable for the proliferation and accumulation of CB in source waters in order to adjust drinking water treatment accordingly. Thus, a new methodology with locally adaptable variables is proposed in order to have a single index, f(p), related to various environmental factors such as temperature, wind speed and direction. The index is used in conjunction with real time monitoring data to determine the probability of CB occurrence in relation to meteorological factors, and was tested at a drinking water intake in Missisquoi Bay, a shallow transboundary bay in Lake Champlain, Québec, Canada. These environmental factors alone were able to explain a maximum probability of 68% that a CB bloom would occur at the drinking water treatment plant. Nutrient limitation also influences CB blooms and intense blooms only occurred when the dissolved inorganic nitrogen (DIN) to total phosphorus (TP) mass ratio was below 3. Additional monitoring of DIN and TP could be considered for these source waters prone to cyanobacterial blooms to determine periods of favourable growth. Real time monitoring and the use of the index could permit an adequate and timely response to CB blooms in drinking water sources. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Continuation of Health Behaviors: Psychosocial Factors Sustaining Drinking Water Chlorination in a Longitudinal Study from Chad

    Directory of Open Access Journals (Sweden)

    Jonathan Lilje

    2016-11-01

    Full Text Available Behavior that has changed following promotion campaigns is usually not maintained at its initial level. Psychosocial factors for initiating behavior are often not the same as for the continuation of health behaviors such as water treatment and are much less understood. Better knowledge of factors for behavioral continuation would help to improve programs, both in the design of strategies for sustainable behavior change and by defining stronger criteria for the evaluation of sustainability. This study compared the mindsets of caregivers who continuously performed household drinking water treatment over time with individuals that stopped doing so in a population sample from Chad. Several factors from health psychology based on the Risks, Attitudes, Norms, Abilities, and Self-Regulation (RANAS model were used to compare the two groups and examine their differing development. Normative factors such as others’ behavior, personal obligation, social support and discourse, perceived self-efficacy convictions, action control, and intention best discriminated between the two groups and developed significantly more positively over time for continuers of water treatment. These factors should be considered when designing future interventions intended to lead to sustainable behavior change.

  9. The Benefits of Including Clinical Factors in Rectal Normal Tissue Complication Probability Modeling After Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Defraene, Gilles; Van den Bergh, Laura; Al-Mamgani, Abrahim; Haustermans, Karin; Heemsbergen, Wilma; Van den Heuvel, Frank; Lebesque, Joos V.

    2012-01-01

    Purpose: To study the impact of clinical predisposing factors on rectal normal tissue complication probability modeling using the updated results of the Dutch prostate dose-escalation trial. Methods and Materials: Toxicity data of 512 patients (conformally treated to 68 Gy [n = 284] and 78 Gy [n = 228]) with complete follow-up at 3 years after radiotherapy were studied. Scored end points were rectal bleeding, high stool frequency, and fecal incontinence. Two traditional dose-based models (Lyman-Kutcher-Burman (LKB) and Relative Seriality (RS) and a logistic model were fitted using a maximum likelihood approach. Furthermore, these model fits were improved by including the most significant clinical factors. The area under the receiver operating characteristic curve (AUC) was used to compare the discriminating ability of all fits. Results: Including clinical factors significantly increased the predictive power of the models for all end points. In the optimal LKB, RS, and logistic models for rectal bleeding and fecal incontinence, the first significant (p = 0.011–0.013) clinical factor was “previous abdominal surgery.” As second significant (p = 0.012–0.016) factor, “cardiac history” was included in all three rectal bleeding fits, whereas including “diabetes” was significant (p = 0.039–0.048) in fecal incontinence modeling but only in the LKB and logistic models. High stool frequency fits only benefitted significantly (p = 0.003–0.006) from the inclusion of the baseline toxicity score. For all models rectal bleeding fits had the highest AUC (0.77) where it was 0.63 and 0.68 for high stool frequency and fecal incontinence, respectively. LKB and logistic model fits resulted in similar values for the volume parameter. The steepness parameter was somewhat higher in the logistic model, also resulting in a slightly lower D 50 . Anal wall DVHs were used for fecal incontinence, whereas anorectal wall dose best described the other two endpoints. Conclusions

  10. The Benefits of Including Clinical Factors in Rectal Normal Tissue Complication Probability Modeling After Radiotherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Defraene, Gilles, E-mail: gilles.defraene@uzleuven.be [Radiation Oncology Department, University Hospitals Leuven, Leuven (Belgium); Van den Bergh, Laura [Radiation Oncology Department, University Hospitals Leuven, Leuven (Belgium); Al-Mamgani, Abrahim [Department of Radiation Oncology, Erasmus Medical Center - Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Haustermans, Karin [Radiation Oncology Department, University Hospitals Leuven, Leuven (Belgium); Heemsbergen, Wilma [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Van den Heuvel, Frank [Radiation Oncology Department, University Hospitals Leuven, Leuven (Belgium); Lebesque, Joos V. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

    2012-03-01

    Purpose: To study the impact of clinical predisposing factors on rectal normal tissue complication probability modeling using the updated results of the Dutch prostate dose-escalation trial. Methods and Materials: Toxicity data of 512 patients (conformally treated to 68 Gy [n = 284] and 78 Gy [n = 228]) with complete follow-up at 3 years after radiotherapy were studied. Scored end points were rectal bleeding, high stool frequency, and fecal incontinence. Two traditional dose-based models (Lyman-Kutcher-Burman (LKB) and Relative Seriality (RS) and a logistic model were fitted using a maximum likelihood approach. Furthermore, these model fits were improved by including the most significant clinical factors. The area under the receiver operating characteristic curve (AUC) was used to compare the discriminating ability of all fits. Results: Including clinical factors significantly increased the predictive power of the models for all end points. In the optimal LKB, RS, and logistic models for rectal bleeding and fecal incontinence, the first significant (p = 0.011-0.013) clinical factor was 'previous abdominal surgery.' As second significant (p = 0.012-0.016) factor, 'cardiac history' was included in all three rectal bleeding fits, whereas including 'diabetes' was significant (p = 0.039-0.048) in fecal incontinence modeling but only in the LKB and logistic models. High stool frequency fits only benefitted significantly (p = 0.003-0.006) from the inclusion of the baseline toxicity score. For all models rectal bleeding fits had the highest AUC (0.77) where it was 0.63 and 0.68 for high stool frequency and fecal incontinence, respectively. LKB and logistic model fits resulted in similar values for the volume parameter. The steepness parameter was somewhat higher in the logistic model, also resulting in a slightly lower D{sub 50}. Anal wall DVHs were used for fecal incontinence, whereas anorectal wall dose best described the other two endpoints

  11. Factors influencing adoption of soil and water conservation measures in southern Mali

    NARCIS (Netherlands)

    Bodnar, F.; Graaff, de J.

    2003-01-01

    A soil and water conservation (SWC) extension programme, promoting erosion control measures and soil fertility measures, has been going on in southern Mali since 1986. Five factors that influence farmer adoption of SWC measures were analysed: land pressure, cotton-growing area, possession of

  12. Water weakening of chalk explaied from a fluid-solid friction factor

    DEFF Research Database (Denmark)

    Andreassen, Katrine Alling; Fabricius, Ida Lykke

    2010-01-01

    to where it is dominated by inertial forces, i.e. when the pore fluid motion lags behind the applied frequency. It is therefore a measure of the internal surface friction between solid and fluid which can be interpreted as a friction factor on the pore scale and we propose it can be extrapolated...... using the Biot critical frequency as a single reference. Other viscoplastic parameters were investigated in the same manner to verify the range of the functioning of the friction factor. The findings show that the Biot critical frequency can be used as a common friction factor and is useful in combining...... laboratory results. It is also inferred that the observed water weakening phenomenon may be attributed to the friction between solid and fluid....

  13. Water, Water Everywhere, But....Notes for the Teacher, Report Writing Directions and Experiments.

    Science.gov (United States)

    Jacobson, Cliff

    Provided in this teaching package are materials that clearly and simply unveil the mysteries of water pollution. Materials, written on an approximate seventh-grade level, include: (1) a student reading unit; (2) water quality factors pamphlet; (3) experiments; and (4) teacher's guide to field testing a local waterway. The student reading unit is…

  14. Behavioral factors to include in guidelines for lifelong oral healthiness: an observational study in Japanese adults

    Directory of Open Access Journals (Sweden)

    Shimozato Miho

    2006-12-01

    Full Text Available Abstract Background The aim of this study was to determine which behavioral factors to include in guidelines for the Japanese public to achieve an acceptable level of oral healthiness. The objective was to determine the relationship between oral health related behaviors and symptoms related to oral disease and tooth loss in a Japanese adult community. Methods Oral health status and lifestyle were investigated in 777 people aged 20 years and older (390 men and 387 women. Subjects were asked to complete a postal questionnaire concerning past diet and lifestyle. The completed questionnaires were collected when they had health examinations. The 15 questions included their preference for sweets, how many between-meal snacks they usually had per day, smoking and drinking habits, presence of oral symptoms, and attitudes towards dental visits. Participants were asked about their behaviors at different stages of their life. The oral health examinations included examination of the oral cavity and teeth performed by dentists using WHO criteria. Odds ratios were calculated for all subjects, all 10 year age groups, and for subjects 30 years or older, 40 years or older, 50 years or older, and 60 years or older. Results Frequency of tooth brushing (OR = 3.98, having your own toothbrush (OR = 2.11, smoking (OR = 2.71 and bleeding gums (OR = 2.03 were significantly associated with number of retained teeth in males. Frequency of between-meal snacks was strongly associated with number of retained teeth in females (OR = 4.67. Having some hobbies (OR = 2.97, having a family dentist (OR = 2.34 and consulting a dentist as soon as symptoms occurred (OR = 1.74 were significantly associated with number of retained teeth in females. Factors that were significantly associated with tooth loss in both males and females included alcohol consumption (OR = 11.96, males, OR = 3.83, females, swollen gums (OR = 1.93, males, OR = 3.04, females and toothache (OR = 3.39, males, OR

  15. On factors influencing air-water gas exchange in emergent wetlands

    Science.gov (United States)

    Ho, David T.; Engel, Victor C.; Ferron, Sara; Hickman, Benjamin; Choi, Jay; Harvey, Judson W.

    2018-01-01

    Knowledge of gas exchange in wetlands is important in order to determine fluxes of climatically and biogeochemically important trace gases and to conduct mass balances for metabolism studies. Very few studies have been conducted to quantify gas transfer velocities in wetlands, and many wind speed/gas exchange parameterizations used in oceanographic or limnological settings are inappropriate under conditions found in wetlands. Here six measurements of gas transfer velocities are made with SF6 tracer release experiments in three different years in the Everglades, a subtropical peatland with surface water flowing through emergent vegetation. The experiments were conducted under different flow conditions and with different amounts of emergent vegetation to determine the influence of wind, rain, water flow, waterside thermal convection, and vegetation on air-water gas exchange in wetlands. Measured gas transfer velocities under the different conditions ranged from 1.1 cm h−1 during baseline conditions to 3.2 cm h−1 when rain and water flow rates were high. Commonly used wind speed/gas exchange relationships would overestimate the gas transfer velocity by a factor of 1.2 to 6.8. Gas exchange due to thermal convection was relatively constant and accounted for 14 to 51% of the total measured gas exchange. Differences in rain and water flow among the different years were responsible for the variability in gas exchange, with flow accounting for 37 to 77% of the gas exchange, and rain responsible for up to 40%.

  16. An exploration of factors that influence the regular consumption of water by Irish primary school children.

    LENUS (Irish Health Repository)

    Molloy, C Johnston

    2008-10-01

    Inadequate hydration has been linked to many factors that may impact on children\\'s education and health. Teachers play an important role in the education and behaviour of children. Previous research has demonstrated low water intake amongst children and negative teachers\\' attitudes to water in the classroom. The present study aimed to explore teachers\\' knowledge about water and the perceived barriers to allowing children access to water during lesson time.

  17. Factors associated with post-treatment E. coli contamination in households practising water treatment: a study of rural Cambodia.

    Science.gov (United States)

    Benwic, Aaron; Kim, Erin; Khema, Cinn; Phanna, Chet; Sophary, Phan; Cantwell, Raymond E

    2018-04-01

    The purpose of this study was to assess factors associated with Escherichia coli (E. coli) contamination in rural households in Cambodia that have adopted household water treatment. The following factors were significantly associated (α E. coli contamination: cleaning the drinking vessel with untreated water, not drying the cup (with a cloth), accessing treated water by the use of a scoop (ref: using a tap), having more than one untreated water storage container, having an untreated water storage container that appeared dirty on the outside, and cows living within 10 m of the household. This study provides further evidence confirming previous studies reporting an association between inadequate cleanliness of water storage containers and household drinking water contamination, and identifies practical recommendations statistically associated with reduced post-treatment E. coli contamination in the household setting in rural Cambodia.

  18. Extraction of steviol glycosides from fresh Stevia using acidified water; comparison to hot water extraction, including purification

    NARCIS (Netherlands)

    Kootstra, A.M.J.; Huurman, Sander

    2017-01-01

    This report describes a practical comparison of an acidified water extraction of freshly harvested Stevia
    plants (the NewFoss method) to the hot water extraction of dried Stevia plants, the industry standard. Both
    extracts are subsequently purified using lab-/bench scale standard industrial

  19. The Importance of Water Temperature Fluctuations in Relation to the Hydrological Factor. Case Study – Bistrita River Basin (Romania

    Directory of Open Access Journals (Sweden)

    Cojoc Gianina Maria

    2014-10-01

    Full Text Available The increase in most components of the climate over the past 50 years, including air and water temperature, is a real phenomenon, as attested by the numerous specialized researches according to IPCC (2013. The water temperature is one of the most important climatic components in analyzing the hydrological regime of the Bistrita River (Romania. The thermal regime of the Bistrita River basin and the frost phenomena associated with the risk factor are particularly important and frequently appear in this area. In recent years, under the Siret Water Basin Administration, this parameter was permanently monitored, so we could do an analysis, which shows that the water temperature fluctuations, influenced by air temperature, lead to the emergence of the ice jam phenomenon. The present study aims to analyze the water temperature, as compared to the air temperature, and the effect of these components on the liquid flow regime (the values were recorded at the hydrological stations on the main course of the Bistrita River. The negative effects resulted from the ice jam phenomenon require developing methods of damage prevention and defense. The frost phenomena recorded after the construction of the Bicaz dam are analyzed in this article

  20. Factors affecting water strider (Hemiptera: Gerridae) mercury concentrations in lotic systems

    Energy Technology Data Exchange (ETDEWEB)

    Jardine, T.D.; Kidd, K.A.; Cunjak, R.A.; Arp, P.A. [University of New Brunswick, St John, NB (Canada). Canadian Rivers Institute

    2009-07-15

    Water striders (Hemiptera: Gerridae) have been considered as a potential sentinel for mercury (Hg) contamination of freshwater ecosystems, yet little is known about factors that control Hg concentrations in this invertebrate. Striders were collected from 80 streams and rivers in New Brunswick, Canada, in August and September of 2004 through 2007 to assess the influence of factors such as diet, water chemistry, and proximity to point sources on Hg concentrations in this organism. Higher than average Hg concentrations were observed in the southwest and Grand Lake regions of the province, the latter being the location of a coal-fired power plant that is a source of Hg (similar to 100 kg annually), with elevated Hg concentrations in the lichen Old Man's Beard (Usnea spp.) in its immediate vicinity. Across all streams, pH and total organic carbon of water were relatively weak predictors of strider Hg concentrations. Female striders that were larger in body size than males had significantly lower Hg concentrations within sites, suggestive of growth dilution. There was no relationship between percent aquatic carbon in the diet and Hg concentrations in striders. For those striders feeding solely on terrestrial carbon, Hg concentrations were higher in animals occupying a higher trophic level. Mercury concentrations were highly variable in striders collected monthly over two growing seasons, suggesting short-term changes in Hg availability. These measurements highlight the importance of considering both deposition and postdepositional processes in assessing Hg bioaccumulation in this species.

  1. Detour factors in water and plastic phantoms and their use for range and depth scaling in electron-beam dosimetry

    International Nuclear Information System (INIS)

    Fernandez-Varea, J.M.; Andreo, P.; Tabata, T.

    1996-01-01

    Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour factors from alternative definitions previously proposed in the literature. Different procedures used in low-energy electron-beam dosimetry to convert ranges and depths measured in plastic phantoms into water-equivalent ranges and depths are analysed. A new simple and accurate scaling method, based on Monte Carlo-derived ratios of average electron penetration depths and thus incorporating the effect of multiple scattering, is presented. Data are given for most plastics used in electron-beam dosimetry together with a fit which extends the method to any other low-Z plastic material. A study of scaled depth - dose curves and mean energies as a function of depth for some plastics of common usage shows that the method improves the consistency and results of other scaling procedures in dosimetry with electron beams at therapeutic energies. (author)

  2. Factors affecting continued use of ceramic water purifiers distributed to Tsunami-affected Communities in Sri Lanka

    OpenAIRE

    Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D

    2012-01-01

    Objectives  There is little information about continued use of point-of-use technologies after disaster relief efforts. After the 2004 tsunami, the Red Cross distributed ceramic water filters in Sri Lanka. This study determined factors associated with filter disuse and evaluate the quality of household drinking water. Methods  A cross-sectional survey of water sources and treatment, filter use and household characteristics was administered by in-person oral interview, and household water qual...

  3. Evaluating the impacts of membrane type, coating, fouling, chemical properties and water chemistry on reverse osmosis rejection of seven nitrosoalklyamines, including NDMA.

    Science.gov (United States)

    Steinle-Darling, Eva; Zedda, Marco; Plumlee, Megan H; Ridgway, Harry F; Reinhard, Martin

    2007-09-01

    Reverse osmosis (RO) treatment has been found to be effective for a wide range of organics but generally small, polar, uncharged molecules such as N-nitrosodimethylamine (NDMA) can be poorly rejected. The rejection of seven N-nitrosoalkylamines with molecular masses in the range of 78-158Da, including NDMA, N-nitrosodiethylamine (NDEA), N-nitrosomethylethylamine (NMEA), N-nitrosodipropylamine (NDPA), N-nitrosodibutylamine (NDBA), N-nitrosopyrrolidine (NPyr), N-nitrosopiperidine (NPip) by three commercial brackish-water reverse osmosis membranes was studied in flat-sheet cells under cross-flow conditions. The membranes used were ESPA3 (Hydranautics), LFC3 (Hydranautics) and BW-30 (Dow/Filmtec), commonly used in water reuse applications. The effects of varying ionic strength and pH, dip-coating membranes with PEBAX 1657, a hydrophilic polymer, and artificial fouling with alginate on nitrosamine rejection were quantified. Rejection in deionized (DI) water increased with molecular mass from 56 to 70% for NDMA, to 80-91% for NMEA, 89-97% for NPyr, 92-98% for NDEA, and to beyond the detection limits for NPip, NDPA and NDBA. For the nitrosamines with quantifiable transmission, linear correlations (r(2)>0.97) were found between the number of methyl groups and the log(transmission), with factor 0.35 to 0.55 decreases in transmission per added methyl group. A PEBAX coating lowered the ESPA3 rejection of NDMA by 11% but increased the LFC3 and BW30 rejection by 6% and 15%, respectively. Artificially fouling ESPA3 membrane coupons with 170g/m(2) alginate decreased the rejection of NDMA by 18%. A feed concentration of 100mM NaCl decreased rejection of NDMA by 15% and acidifying the DI water feed to pH=3 decreased the rejection by 5%, whereas increasing the pH to 10 did not have a significant (p<0.05) effect.

  4. Framework Design and Influencing Factor Analysis of a Water Environmental Functional Zone-Based Effluent Trading System

    Science.gov (United States)

    Chen, Lei; Han, Zhaoxing; Li, Shuang; Shen, Zhenyao

    2016-10-01

    The efficacy of traditional effluent trading systems is questionable due to their neglect of seasonal hydrological variation and the creation of upstream hot spots within a watershed. Besides, few studies have been conducted to distinguish the impacts of each influencing factor on effluent trading systems outputs. In this study, a water environmental functional zone-based effluent trading systems framework was configured and a comprehensive analysis of its influencing factors was conducted. This proposed water environmental functional zone-based effluent trading systems was then applied for the control of chemical oxygen demand in the Beiyun River watershed, Beijing, China. Optimal trading results highlighted the integration of water quality constraints and different hydrological seasons, especially for downstream dischargers. The optimal trading of each discharger, in terms of pollutant reduction load and abatement cost, is greatly influenced by environmental and political factors such as background water quality, the location of river assessment points, and tradable discharge permits. In addition, the initial permit allowance has little influence on the market as a whole but does impact the individual discharger. These results provide information that is critical to understanding the impact of policy design on the functionality of an effluent trading systems.

  5. Framework Design and Influencing Factor Analysis of a Water Environmental Functional Zone-Based Effluent Trading System.

    Science.gov (United States)

    Chen, Lei; Han, Zhaoxing; Li, Shuang; Shen, Zhenyao

    2016-10-01

    The efficacy of traditional effluent trading systems is questionable due to their neglect of seasonal hydrological variation and the creation of upstream hot spots within a watershed. Besides, few studies have been conducted to distinguish the impacts of each influencing factor on effluent trading systems outputs. In this study, a water environmental functional zone-based effluent trading systems framework was configured and a comprehensive analysis of its influencing factors was conducted. This proposed water environmental functional zone-based effluent trading systems was then applied for the control of chemical oxygen demand in the Beiyun River watershed, Beijing, China. Optimal trading results highlighted the integration of water quality constraints and different hydrological seasons, especially for downstream dischargers. The optimal trading of each discharger, in terms of pollutant reduction load and abatement cost, is greatly influenced by environmental and political factors such as background water quality, the location of river assessment points, and tradable discharge permits. In addition, the initial permit allowance has little influence on the market as a whole but does impact the individual discharger. These results provide information that is critical to understanding the impact of policy design on the functionality of an effluent trading systems.

  6. Factors responsible for the patchy distribution of natural soil water repellency in Mediterranean semiarid forest

    Science.gov (United States)

    Lozano, E.; Jiménez-Pinilla, P.; Mataix-Solera, J.; González-Pérez, J. A.; García-Orenes, F.; Torres, M. P.; Arcenegui, V.; Mataix-Beneyto, J.

    2012-04-01

    H and between SOM and pH for all except for Q. rotundifolia. However, the negative correlation found between pH and persistence of WR seems to be related to soil organic matter (SOM) content for all vegetal species. Glomalin exudates from arbuscular mycorrhizal fungi in soil revealed significant differences between species. However, the first results do not point to a direct relationship between EEG content and WR but to soil mineralogy or certain components within SOM pool i.e. litter debris degradation products or specific components within the glomalin extract, as main factors affecting soil WR. Nonetheless, since some samples with the same SOM content (including some under the same vegetation cover) showed different WR persistence, complementary research including a more detailed characterization of most soil functional fractions (SOM and clays) is planned in order to elucidat the main factors influencing the presence and persistence of WR in soils under Mediterranean semiarid forest. Keywords: Water repellency, hydrophobicity, easily extractable glomalin, mycelium, arbuscular mycorrhizal fungi.

  7. Evaluation of dripper clogging using magnetic water in drip irrigation

    Science.gov (United States)

    Khoshravesh, Mojtaba; Mirzaei, Sayyed Mohammad Javad; Shirazi, Pooya; Valashedi, Reza Norooz

    2018-06-01

    This study was performed to investigate the uniformity of distribution of water and discharge variations in drip irrigation using magnetic water. Magnetic water was achieved by transition of water using a robust permanent magnet connected to a feed pipeline. Two main factors including magnetic and non-magnetic water and three sub-factor of salt concentration including well water, addition of 150 and 300 mg L-1 calcium carbonate to irrigation water with three replications were applied. The result of magnetic water on average dripper discharge was significant at ( P ≤ 0.05). At the final irrigation, the average dripper discharge and distribution uniformity were higher for the magnetic water compared to the non-magnetic water. The magnetic water showed a significant effect ( P ≤ 0.01) on distribution uniformity of drippers. At the first irrigation, the water distribution uniformity was almost the same for both the magnetic water and the non-magnetic water. The use of magnetic water for drip irrigation is recommended to achieve higher uniformity.

  8. Growth-supporting activity for Legionella pneumophila in tap water cultures and implication of hartmannellid amoebae as growth factors.

    Science.gov (United States)

    Wadowsky, R M; Butler, L J; Cook, M K; Verma, S M; Paul, M A; Fields, B S; Keleti, G; Sykora, J L; Yee, R B

    1988-11-01

    Photosynthetic cyanobacteria, heterotrophic bacteria, free-living amoebae, and ciliated protozoa may support growth of Legionella pneumophila. Studies were done with two tap water cultures (WS1 and WS2) containing L. pneumophila and associated microbiota to characterize growth-supporting activity and assess the relative importance of the microbiota in supporting multiplication of L. pneumophila. The water cultures were incubated in the dark at 35 degrees C. The growth-supporting factor(s) was separated from each culture by filtration through 1-micron-pore-size membrane filters. The retentate was then suspended in sterile tap water. Multiplication of L. pneumophila occurred when both the retentate suspension and the filtrate from either culture were inoculated into sterile tap water. L. pneumophila did not multiply in tap water inoculated with only the filtrate, even though filtration did not reduce the concentration of L. pneumophila or heterotrophic bacteria in either culture. Growth-supporting activity of the retentate suspension from WS1 was inactivated at 60 degrees C but unaffected at 0, 25, and 45 degrees C after 30-min incubations. Filtration experiments indicated that the growth-supporting factor(s) in WS1 was 2 to 5 micron in diameter. Ciliated protozoa were not detected in either culture. Hartmannellid amoebae were conclusively demonstrated in WS2 but not in WS1. L. pneumophila multiplied in tap water inoculated with the amoebae (10(3)/ml) and the 1-micron filtrate of WS2. No multiplication occurred in tap water inoculated with the filtrate only. Growth-supporting activity for L. pneumophila may be present in plumbing systems; hartmannellid amoebae appear to be important determinants of multiplication of L. pneumophila in some tap water cultures.

  9. Effect of Water Chemistry Factors on Flow Accelerated Corrosion : pH, DO, Hydrazine

    International Nuclear Information System (INIS)

    Lee, Eun Hee; Kim, Kyung Mo; Kim, Hong Pyo

    2013-01-01

    Flow accelerated corrosion(FAC) of the carbon steel piping in pressurized water reactors(PWRs) has been major issue in nuclear industry. Severe accident at Surry Unit 2 in 1986 initiated the worldwide interest in this area. Major parameters influencing FAC are material composition, microstructure, water chemistry, and hydrodynamics. Qualitative behaviors of FAC have been well understood but quantitative data about FAC have not been published for proprietary reason. In order to minimize the FAC in PWRs, the optimal method is to control water chemistry factors. Chemistry factors influencing FAC such as pH, corrosion potential, and hydrazine contents were reviewed in this paper. FAC rate decreased with pH up to 10 because magnetite solubility decreased with pH. Corrosion potential is generally controlled dissolved oxygen (DO) and hydrazine in secondary water. DO increased corrosion potential. FAC rate decreased with DO by stabilizing magnetite at low DO concentration or by formation of hematite at high DO concentration. Even though hydrazine is generally used to remove DO, hydrazine itself thermally decomposed to ammonia, nitrogen, and hydrogen raising pH. Hydrazine could react with iron and increased FAC rate. Effect of hydrazine on FAC is rather complex and should be careful in FAC analysis. FAC could be managed by adequate combination of pH, corrosion potential, and hydrazine

  10. Policies for including disabled people in education. obstacles and facilitating factors for their implementation: Bucaramanga, 2010

    Directory of Open Access Journals (Sweden)

    Claudia P. Serrano R

    2011-07-01

    Full Text Available Objective: to explore the factors enabling or hindering the implementation of inclusive education policies for the disabled population of Bucaramanga. Methodology: a descriptive study, involving representatives from governmental agencies (EG, members of the faculty boards of educational institutions (DIE and guardians of disabled individuals (APSD. Physical, social, and political obstacles and facilitating factors that could potentially determine the implementation of these policies were analyzed. Data was collected through interviews. Results: there was a total of 2, 32, and 34 participants from the EG, DIE, and APSD groups respectively. Identified obstacles included: lack of strategies to support educational institutions, poor or limited teacher training, high tuition fees, and negative attitude towards disability. The facilitating factors included: availability of places, inclusion of this issue in the political agenda, and desire of the disabled individuals’ families to provide them with education. Discussion: These findings provide useful information for further research on this issue and show how action has been taken, as well as how urgent it is to establish a direct relationship between academia and the public sector to propose strategies for assessing and modifying these policies.

  11. Modeling water quality in an urban river using hydrological factors--data driven approaches.

    Science.gov (United States)

    Chang, Fi-John; Tsai, Yu-Hsuan; Chen, Pin-An; Coynel, Alexandra; Vachaud, Georges

    2015-03-15

    Contrasting seasonal variations occur in river flow and water quality as a result of short duration, severe intensity storms and typhoons in Taiwan. Sudden changes in river flow caused by impending extreme events may impose serious degradation on river water quality and fateful impacts on ecosystems. Water quality is measured in a monthly/quarterly scale, and therefore an estimation of water quality in a daily scale would be of good help for timely river pollution management. This study proposes a systematic analysis scheme (SAS) to assess the spatio-temporal interrelation of water quality in an urban river and construct water quality estimation models using two static and one dynamic artificial neural networks (ANNs) coupled with the Gamma test (GT) based on water quality, hydrological and economic data. The Dahan River basin in Taiwan is the study area. Ammonia nitrogen (NH3-N) is considered as the representative parameter, a correlative indicator in judging the contamination level over the study. Key factors the most closely related to the representative parameter (NH3-N) are extracted by the Gamma test for modeling NH3-N concentration, and as a result, four hydrological factors (discharge, days w/o discharge, water temperature and rainfall) are identified as model inputs. The modeling results demonstrate that the nonlinear autoregressive with exogenous input (NARX) network furnished with recurrent connections can accurately estimate NH3-N concentration with a very high coefficient of efficiency value (0.926) and a low RMSE value (0.386 mg/l). Besides, the NARX network can suitably catch peak values that mainly occur in dry periods (September-April in the study area), which is particularly important to water pollution treatment. The proposed SAS suggests a promising approach to reliably modeling the spatio-temporal NH3-N concentration based solely on hydrological data, without using water quality sampling data. It is worth noticing that such estimation can be

  12. Quantifying the economic water savings benefit of water hyacinth (Eichhornia crassipes) control in the Vaalharts Irrigation Scheme

    OpenAIRE

    Arp, RS; Fraser, GCG; Hill, MP

    2017-01-01

    Global freshwater resources are threatened by an ever-growing population and continued economic development, highlighting the need for sustainable water management. Sustainable management must include the control of any additional factors that may aggravate water scarcity, such as invasive alien plants. Water hyacinth (Eichhornia crassipes), one of the world's most destructive invasive plants, presents a direct threat to economically productive water resources. Through high levels of evapotra...

  13. Assessment of factors which affect multiple uses of water sources at household level in rural Zimbabwe - A case study of Marondera, Murehwa and Uzumba Maramba Pfungwe districts

    Science.gov (United States)

    Katsi, Luckson; Siwadi, Japson; Guzha, Edward; Makoni, Fungai S.; Smits, Stef

    Water with all its multiple uses plays a pivotal role in the sustenance of rural livelihoods, especially the poor. As such, the provision of water which go beyond domestic to include water for small-scale productive uses should be encouraged to enhance peoples’ livelihood options by making significant contribution to household income, food security, improved nutrition and health. All these multiple benefits, if combined can assist in the fight against hunger and poverty. This study was conducted in Mashonaland East province, covering Marondera, Murehwa and Uzumba Maramba Pfungwe districts in Zimbabwe for the period December 2005-May 2006 to assess factors which affect multiple uses of water sources at household level. Participatory Rural Appraisal tools such as discussions, observations and interviews were used for data collection. The survey found that people indeed require water for productive purposes apart from domestic uses, which are often given top priority. The study found out that multiple uses of water sources at household level can be affected by segmentation of water services into domestic and productive water supply schemes, technology and system design, water quality and quantity and distance to water sources among other factors. The study recommends that water service providers to be able to provide appropriate, efficient and sustainable services, they should understand and appreciate that people’s water needs are integrated and are part and parcel of their multifaceted livelihood strategies.

  14. Models of the Water Systems in Mauritius

    OpenAIRE

    Toth, F.L.

    1992-01-01

    Criteria for sustainable development in terms of managing a nation's water resources include the availability of water in required quantity and appropriate quality. This paper presents a set of water models developed for the IIASA/UNFPA Mauritius Project for use as an integral part of a system of models including demographic, economic, and land use models. The paper identifies the most important factors determining the available freshwater resources in Mauritius (climate, geology, hydrology),...

  15. Water scarcity, market-based incentives, and consumer response

    Science.gov (United States)

    Krause, K.; Chermak, J. M.; Brookshire, D. S.

    2003-04-01

    Water is an increasingly scarce resource and the future viability of many regions will depend in large part on how efficiently resources are utilized. A key factor to this success will be a thorough understanding of consumers and the characteristics that drive their water use. In this research test and find support for the hypothesis that residential water consumers are heterogeneous. We combine experimental and survey responses to test for statistically significant consumer characteristics that are observable factors of demand for water. Significant factors include "stage of life" (i.e., student versus workforce versus retired), as well as various social and cultural factors including age, ethnicity, political affiliation and religious affiliation. Identification of these characteristics allows us to econometrically estimate disaggregated water demand for a sample of urban water consumers in Albuquerque, New Mexico, USA. The results provide unique parameter estimates for different consumer types. Using these results we design an incentive compatible, non-linear pricing program that allows individual consumers to choose a fixed fee/commodity charge from a menu that not only allows the individual to maximize his or her utility, while meeting the conservation goals of the program. We show that this program, with the attention to consumer differences is more efficient than the traditional "one size fits all" programs commonly employed by many water utilities.

  16. Factors affecting continued use of ceramic water purifiers distributed to tsunami-affected communities in Sri Lanka.

    Science.gov (United States)

    Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D

    2012-11-01

    There is little information about continued use of point-of-use technologies after disaster relief efforts. After the 2004 tsunami, the Red Cross distributed ceramic water filters in Sri Lanka. This study determined factors associated with filter disuse and evaluate the quality of household drinking water. A cross-sectional survey of water sources and treatment, filter use and household characteristics was administered by in-person oral interview, and household water quality was tested. Multivariable logistic regression was used to model probability of filter non-use. At the time of survey, 24% of households (107/452) did not use filters; the most common reason given was breakage (42%). The most common household water sources were taps and wells. Wells were used by 45% of filter users and 28% of non-users. Of households with taps, 75% had source water Escherichia coli in the lowest World Health Organisation risk category (<1/100 ml), vs. only 30% of households reporting wells did. Tap households were approximately four times more likely to discontinue filter use than well households. After 2 years, 24% of households were non-users. The main factors were breakage and household water source; households with taps were more likely to stop use than households with wells. Tap water users also had higher-quality source water, suggesting that disuse is not necessarily negative and monitoring of water quality can aid decision-making about continued use. To promote continued use, disaster recovery filter distribution efforts must be joined with capacity building for long-term water monitoring, supply chains and local production. © 2012 Blackwell Publishing Ltd.

  17. Energy-Water Modeling and Analysis | Energy Analysis | NREL

    Science.gov (United States)

    Generation (ReEDS Model Analysis) U.S. Energy Sector Vulnerabilities to Climate Change and Extreme Weather Modeling and Analysis Energy-Water Modeling and Analysis NREL's energy-water modeling and analysis vulnerabilities from various factors, including water. Example Projects Renewable Electricity Futures Study

  18. Analysis of the natural factors of biological productivity of water bodies in the different landscapes of Karelia

    Directory of Open Access Journals (Sweden)

    Tekanova Elena Valentinovna

    2017-06-01

    Full Text Available Abiotic environmental factors of biological productivity were studied in seven lakes with low water exchange and a few inflows in different landscapes of Karelia (Russia. Lakes are not exposed to human impact. An indicator of the biological productivity is the phytoplankton photosynthesis rate calculated on the concentration of phosphorus in water. The water bodies vary from oligotrophic to mesotrophic according to their trophic level. Cluster and component analysis of chemicals was carried out, hydrological, morphometric and landscape characteristics of the lakes were also determined. It was shown that in the absence of anthropogenic influence the availability of phosphorus and trophic level of the studied lakes in the humid zone are determined by the water exchange, effluent per unit of water column, color of water and landscape features. The most productive water bodies are located on the fluvioglacial and moraine plains dominated by podsolic soils, which have a good flashing regime and soluble humus substances. These lakes are distinguished by a larger inflow of phosphorus forming a part of humus substances originated from the water-collecting area per unit of water column. Oligotrophic lakes are located in moraine and selga landscapes dominated by podbours and brown soils with a lot of humus slightly transformed. These lakes are characterized by less water exchange and drainage factor, and, accordingly, low values of phosphorus input and water color.

  19. Seismic evaluation of a cooling water reservoir facility including fluid-structure and soil-structure interaction effects

    International Nuclear Information System (INIS)

    Kabir, A.F.; Maryak, M.E.

    1991-01-01

    Seismic analyses and structural evaluations were performed for a cooling water reservoir of a nuclear reactor facility. The horizontal input seismic motion was the NRC Reg. guide 1.60 spectrum shape anchored at 0.20g zero period acceleration. Vertical input was taken as two-thirds of the horizontal input. Soil structure interaction and hydrodynamic effects were addressed in the seismic analyses. Uncertainties in the soil properties were accounted for by considering three soil profiles. Two 2-dimensional SSI models and a 3-dimensional static model. Representing different areas of the reservoir structures were developed and analyzed to obtain seismic forces and moments, and accelerations at various locations. The results included in this paper indicated that both hydrodynamic and soil-structure interaction effects are significant contributors to the seismic responses of the water-retaining walls of the reservoir

  20. Surface water quality assessment using factor analysis

    African Journals Online (AJOL)

    2006-01-16

    Jan 16, 2006 ... Surface water, groundwater quality assessment and environ- .... Urbanisation influences the water cycle through changes in flow and water ..... tion of aquatic life, CCME water quality Index 1, 0. User`s ... Water, Air Soil Pollut.

  1. Factors affecting ultraviolet irradiation/hydrogen peroxide (UV/H2O2) degradation of mixed N-nitrosamines in water

    International Nuclear Information System (INIS)

    Zhou, Chao; Gao, Naiyun; Deng, Yang; Chu, Wenhai; Rong, Wenlei; Zhou, Shengdong

    2012-01-01

    Highlights: ► NAms with three-induced toxicity, as emerging DBPs, has caused a great public attention. ► No paper regards UV/H 2 O 2 oxidation of mixed NAms in an aquatic environment. ► The treatment effect is typically affected by a few factors in water. ► NPIP and NDPhA are the most readily and difficult to be degraded due to unique structure. ► All the NAms degradation exhibited a pseudo-first-order kinetics pattern. - Abstract: Disinfection by-products (DBPs) are a great challenge to our drinking water security. Particularly, nitrosamines (NAms), as emerging DBPs, are potently carcinogenic, mutagenic, and teratogenic, and have increasingly attained public attention. This study was to evaluate the performance of the NAms degradation by the ultraviolet (UV) irradiation (253.7 nm) in the presence of hydrogen peroxide (H 2 O 2 ). In the UV/H 2 O 2 system, hydroxyl radicals (OH·), a type of nonselective and powerful oxidant, was produced to attack the molecules of NAms. Factors affecting the treatment efficiency, including the H 2 O 2 dosage, initial NAms concentration, UV irradiation intensity, initial solution pH, and inorganic anions present in water, were evaluated. All the NAms degradation exhibited a pseudo-first-order kinetics pattern. Within 60 min, 0.1 mg/L of any NAms could be almost decomposed except NDPhA that required 120 min for complete removal, at 25 μmol/L H 2 O 2 and at initial pH 7. Results demonstrate that the UV/H 2 O 2 treatment is a viable option to control NAms in water.

  2. Study of Sesame (Sesame indicum L. Cultivars based on Morphological Characteristics Under Water Deficit Stress Condition Using Factor Analysis

    Directory of Open Access Journals (Sweden)

    A Asghari

    2014-03-01

    Full Text Available In order to evaluation sesame cultivars based on morphological characteristics under water deficit stress condition using factor analysis, an experiment was conducted as a split plot based on randomized complete block design with three replications during 2009 in Research Center of Agriculture and Natural Resources in Parsabad. In this experiment, irrigation as the main factor at three levels (50, 75 and 100 percent of crop water requirement and ten sesame cultivars as the sub-factor were studied. The water requirement of sesame was calculated using CROPWAT software (Penman-Monteith method according to FAO-56. Results showed significant differences between the cultivars and the irrigation levels for all studied traits. Interaction between cultivars and irrigation levels was significant for some of traits. Comparisons of means showed that in water deficit condition, yield and all of traits reduced. In all traits the greatest amounts observed in complete irrigation treatment. In 50 percent of water requirement treatment, amount of leaf chlorophyll, root length, root branches and root length/plant height ratio were greater than other treatments. The Karaj1, Ultan, Naze and IS cultivars were better than other cultivars in stress and non stress condition. In factor analysis 5 and 4 first factors in non stress and stress condition explained 91.36 and 89.52 percent of trait variance, respectively. Grouping of sesame cultivars based on first and second factors in non stress conditions showed that Karaj1, Ultan and Naze cultivars were better than other cultivars. Also, in stress conditions Karaj1 and Ultan cultivars grouped as water deficit stress and better cultivars.

  3. Modeling Stochastic Energy and Water Consumption to Manage Residential Water Uses

    Science.gov (United States)

    Abdallah, A. M.; Rosenberg, D. E.; Water; Energy Conservation

    2011-12-01

    Water energy linkages have received growing attention from the water and energy utilities as utilities recognize that collaborative efforts can implement more effective conservation and efficiency improvement programs at lower cost with less effort. To date, limited energy-water household data has allowed only deterministic analysis for average, representative households and required coarse assumptions - like the water heater (the primary energy use in a home apart from heating and cooling) be a single end use. Here, we use recent available disaggregated hot and cold water household end-use data to estimate water and energy consumption for toilet, shower, faucet, dishwasher, laundry machine, leaks, and other household uses and savings from appliance retrofits. The disaggregated hot water and bulk water end-use data was previously collected by the USEPA for 96 single family households in Seattle WA and Oakland CA, and Tampa FL between the period from 2000 and 2003 for two weeks before and four weeks after each household was retrofitted with water efficient appliances. Using the disaggregated data, we developed a stochastic model that represents factors that influence water use for each appliance: behavioral (use frequency and duration), demographical (household size), and technological (use volume or flowrate). We also include stochastic factors that govern energy to heat hot water: hot water fraction (percentage of hot water volume to total water volume used in a certain end-use event), heater water intake and dispense temperatures, and energy source for the heater (gas, electric, etc). From the empirical household end-use data, we derive stochastic probability distributions for each water and energy factor where each distribution represents the range and likelihood of values that the factor may take. The uncertainty of the stochastic water and energy factors is propagated using Monte Carlo simulations to calculate the composite probability distribution for water

  4. Spatial and Temporal Variations of Water Quality and Trophic Status in Xili Reservoir: a Subtropics Drinking Water Reservoir of Southeast China

    Science.gov (United States)

    Yunlong, Song; Zhang, Jinsong; Zhu, Jia; Li, Wang; Chang, Aimin; Yi, Tao

    2017-12-01

    Controlling of water quality pollution and eutrophication of reservoirs has become a very important research topic in urban drinking water field. Xili reservoir is an important water source of drinking water in Shenzhen. And its water quality has played an important role to the city’s drinking water security. A fifteen-month’s field observation was conducted from April 2013 to June 2014 in Xili reservoir, in order to analyze the temporal and spatial distribution of water quality factors and seasonal variation of trophic states. Xili reservoir was seriously polluted by nitrogen. Judged by TN most of the samples were no better than grade VI. Other water quality factor including WT, SD, pH, DO, COD, TOC, TP, Fe, silicate, turbidity, chlorophyll-a were pretty good. One-way ANOVA showed that significant difference was found in water quality factors on month (p Latter rainy period > High temperature and rain free period > Temperature jump period > Winter drought period. Two-way ANOVA showed that months rather than locations were the key influencing factors of water quality factors succession.TLI (Σ) were about 35~52, suggesting Xili reservoir was in mycotrophic trophic states. As a result of runoff pollution, water quality at sampling sites 1 and 10 was poor. In the rainy season, near sampling sites 1 and 10, water appeared to be Light-eutrophic. The phytoplankton biomass of Xili reservoir was low. Water temperature was the main driving factor of phytoplankton succession.The 14 water quality factors were divided into five groups by factor analysis. The total interpretation rate was about 70.82%. F1 represents the climatic change represented by water temperature and organic pollution. F2 represents the concentration of nitrogen. F3 represents the phytoplankton biomass. F4 represents the sensory indexes of water body, such as turbidity, transparency.

  5. Community structure, phytoplankton density and physical-chemical factor of batang palangki waters of sijunjung regency, west sumatera

    Science.gov (United States)

    Gusmaweti; Deswati, L.

    2018-03-01

    The long-term goal of this study is to provide an overview of the presence of phytoplankton in support of its functions in the waters of Batang Palangki as a conservation area of information on river water management, especially for Batang Palangki stakeholders. Specific targets to be achieved in achieving these objectives are (1) to know the density of phytoplankton, index of diversity of species, equitabilty index, domination index, and in Batang Palangki waters, and (2) to analyze the chemical and physical factors of the waters. The sampling method of phytoplankton is purposive sampling. The phytoplankton sampling is done By filtering 100 liters of water into the net plankton no 25 and filtered into the 25 cc, and then identified. The determination of water quality such as water temperature, water pH and watercolour. dissolved oxygen (DO) and BOD, and Hg content (mercury). The results showed that phytoplankton found from each of station was 370 individualis per liter with the highest density found in the station I of 155. The number of genus was 7, namely Neidium, Gyrogsima, Synedra, Frustulia, Fragillaria, Nitzschia and Peridinium. The diversity index averaged at 0.45, equabilty index averaged at 0.54, while the dominance index averaged at 0.28. Physical and chemical factor measurement results found that water temperature averaged at 26 °C, transparency ranged from 12 - 30 cm, velocity speed ranged from 8 - 15 m/s, while chemical factors such as DO, BOD, and COD ranged from 5.25 to 5.96 mg/L, 3.28 - 3.49 mg/L, and 47.05 - 76.25 mg/L respectively. Likewise, TOM measured in this research was 9.61 - 2.10 mg/L while Hg content ranged from 0.098 - 0.208 mg/L.

  6. Electron beam water calorimetry measurements to obtain beam quality conversion factors.

    Science.gov (United States)

    Muir, Bryan R; Cojocaru, Claudiu D; McEwen, Malcolm R; Ross, Carl K

    2017-10-01

    To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, k Q , for several ion chamber types. Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator. Ion chamber measurements are made as a function of depth for cylindrical and plane-parallel ion chambers over a period of five years to investigate the stability of ion chamber response and for indirect calibration. Water calorimetry measurements are made in 18 MeV and 22 MeV beams. An insulated enclosure with fine temperature control is used to maintain a constant temperature (drifts less than 0.1 mK/min) of the calorimeter phantom at 4°C to minimize effects from convection. Two vessels of different designs are used with calibrated thermistor probes to measure radiation induced temperature rise. The vessels are filled with high-purity water and saturated with H 2 or N 2 gas to minimize the effect of radiochemical reactions on the measured temperature rise. A set of secondary standard ion chambers are calibrated directly against the calorimeter. Finally, several other ion chambers are calibrated in the NRC 60 Co reference field and then cross-calibrated against the secondary standard chambers in electron beams to realize k Q factors. The long-term stability of the cylindrical ion chambers in electron beams is better (always <0.15%) than plane-parallel chambers (0.2% to 0.4%). Calorimetry measurements

  7. Driven Factors Analysis of China’s Irrigation Water Use Efficiency by Stepwise Regression and Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Renfu Jia

    2016-01-01

    Full Text Available This paper introduces an integrated approach to find out the major factors influencing efficiency of irrigation water use in China. It combines multiple stepwise regression (MSR and principal component analysis (PCA to obtain more realistic results. In real world case studies, classical linear regression model often involves too many explanatory variables and the linear correlation issue among variables cannot be eliminated. Linearly correlated variables will cause the invalidity of the factor analysis results. To overcome this issue and reduce the number of the variables, PCA technique has been used combining with MSR. As such, the irrigation water use status in China was analyzed to find out the five major factors that have significant impacts on irrigation water use efficiency. To illustrate the performance of the proposed approach, the calculation based on real data was conducted and the results were shown in this paper.

  8. Applying of factor analyses for determination of trace elements distribution in water from Vardar and its tributaries, Macedonia/Greece.

    Science.gov (United States)

    Popov, Stanko Ilić; Stafilov, Trajče; Sajn, Robert; Tănăselia, Claudiu; Bačeva, Katerina

    2014-01-01

    A systematic study was carried out to investigate the distribution of fifty-six elements in the water samples from river Vardar (Republic of Macedonia and Greece) and its major tributaries. The samples were collected from 27 sampling sites. Analyses were performed by mass spectrometry with inductively coupled plasma (ICP-MS) and atomic emission spectrometry with inductively coupled plasma (ICP-AES). Cluster and R mode factor analysis (FA) was used to identify and characterise element associations and four associations of elements were determined by the method of multivariate statistics. Three factors represent the associations of elements that occur in the river water naturally while Factor 3 represents an anthropogenic association of the elements (Cd, Ga, In, Pb, Re, Tl, Cu, and Zn) introduced in the river waters from the waste waters from the mining and metallurgical activities in the country.

  9. Soil salinity and matric potential interaction on water use, water use efficiency and yield response factor of bean and wheat.

    Science.gov (United States)

    Khataar, Mahnaz; Mohhamadi, Mohammad Hossien; Shabani, Farzin

    2018-02-08

    We studied the effects of soil matric potential and salinity on the water use (WU), water use efficiency (WUE) and yield response factor (Ky), for wheat (Triticum aestivum cv. Mahdavi) and bean (Phaseoulus vulgaris cv. COS16) in sandy loam and clay loam soils under greenhouse conditions. Results showed that aeration porosity is the predominant factor controlling WU, WUE, Ky and shoot biomass (Bs) at high soil water potentials. As matric potential was decreased, soil aeration improved, with Bs, WU and Ky reaching maximum value at -6 to -10 kPa, under all salinities. Wheat WUE remained almost unchanged by reduction of matric potential under low salinities (EC ≤ 8 dSm -1 ), but increased under higher salinities (EC ≥ 8 dSm -1 ), as did bean WUE at all salinities, as matric potential decreased to -33 kPa. Wheat WUE exceeds that of bean in both sandy loam and clay loam soils. WUE of both plants increased with higher shoot/root ratio and a high correlation coefficient exists between them. Results showed that salinity decreases all parameters, particularly at high potentials (h = -2 kPa), and amplifies the effects of waterlogging. Further, we observed a strong relationship between transpiration (T) and root respiration (Rr) for all experiments.

  10. User manuals for the Delaware River Basin Water Availability Tool for Environmental Resources (DRB–WATER) and associated WATER application utilities

    Science.gov (United States)

    Williamson, Tanja N.; Lant, Jeremiah G.

    2015-11-18

    The Water Availability Tool for Environmental Resources (WATER) is a decision support system (DSS) for the nontidal part of the Delaware River Basin (DRB) that provides a consistent and objective method of simulating streamflow under historical, forecasted, and managed conditions. WATER integrates geospatial sampling of landscape characteristics, including topographic and soil properties, with a regionally calibrated hillslope-hydrology model, an impervious-surface model, and hydroclimatic models that have been parameterized using three hydrologic response units—forested, agricultural, and developed land cover. It is this integration that enables the regional hydrologic-modeling approach used in WATER without requiring site-specific optimization or those stationary conditions inferred when using a statistical model. The DSS provides a “historical” database, ideal for simulating streamflow for 2001–11, in addition to land-cover forecasts that focus on 2030 and 2060. The WATER Application Utilities are provided with the DSS and apply change factors for precipitation, temperature, and potential evapotranspiration to a 1981–2011 climatic record provided with the DSS. These change factors were derived from a suite of general circulation models (GCMs) and representative concentration pathway (RCP) emission scenarios. These change factors are based on 25-year monthly averages (normals) that are centere on 2030 and 2060. The WATER Application Utilities also can be used to apply a 2010 snapshot of water use for the DRB; a factorial approach enables scenario testing of increased or decreased water use for each simulation. Finally, the WATER Application Utilities can be used to reformat streamflow time series for input to statistical or reservoir management software. 

  11. NEW MASER EMISSION FROM NONMETASTABLE AMMONIA IN NGC 7538. II. GREEN BANK TELESCOPE OBSERVATIONS INCLUDING WATER MASERS

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [St. Paul' s School, Concord, NH 03301 (United States); Seojin Kim, Stella, E-mail: ihoffman@sps.edu [Current address: Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2011-12-15

    We present new maser emission from {sup 14}NH{sub 3} (9,6) in NGC 7538. Our observations include the known spectral features near v{sub LSR} = -60 km s{sup -1} and -57 km s{sup -1} and several more features extending to -46 km s{sup -1}. In three epochs of observation spanning two months we do not detect any variability in the ammonia masers, in contrast to the >10-fold variability observed in other {sup 14}NH{sub 3} (9,6) masers in the Galaxy over comparable timescales. We also present observations of water masers in all three epochs for which emission is observed over the velocity range -105 km s{sup -1} < v{sub LSR} < -4 km s{sup -1}, including the highest velocity water emission yet observed from NGC 7538. Of the remarkable number of maser species in IRS 1, H{sub 2}O and, now, {sup 14}NH{sub 3} are the only masers known to exhibit emission outside of the velocity range -62 km s{sup -1} < v{sub LSR} < -51 km s{sup -1}. However, we find no significant intensity or velocity correlations between the water emission and ammonia emission. We also present a non-detection in the most sensitive search to date toward any source for emission from the CC{sup 32}S and CC{sup 34}S molecules, indicating an age greater than Almost-Equal-To 10{sup 4} yr for IRS 1-3. We discuss these findings in the context of embedded stellar cores and recent models of the region.

  12. A new approach for evaluating water hammer including the initial state of pressurization of the installation and fluid

    Directory of Open Access Journals (Sweden)

    G. Kaless

    2016-04-01

    Full Text Available The water hammer phenomenon is well known since the 19th century, while its mathematical formulation, by means of differential equations, is due to works of researchers such us Allievi (1903 and others from the beginning of the 20th century. The equations found in the technical publications produce a strange water hammer when the initial condition is defined assuming an incompressible fluid and a rigid pipe. The correct solution requires solving the water hammer equations for the initial state. When the finite difference method is applied, the initial state is solved by means of a set of non-linear equations. A novel approach is proposed including the initial state of pressurization into the governing equations and hence simplifying the calculus of the initial conditions. Furthermore, a critical reading of the deduction of the equations is done pointing out conceptual inconsistencies and proposing corrections.

  13. Assessment of water, sanitation, and hygiene practices and associated factors in a Buruli ulcer endemic district in Benin (West Africa).

    Science.gov (United States)

    Johnson, Roch Christian; Boni, Gratien; Barogui, Yves; Sopoh, Ghislain Emmanuel; Houndonougbo, Macaire; Anagonou, Esai; Agossadou, Didier; Diez, Gabriel; Boko, Michel

    2015-08-19

    Control of neglected tropical diseases (NTDs) requires multiple strategic approaches including water, sanitation and hygiene services (WASH). Buruli ulcer (BU), one of the 17 NTDs, remains a public health issue in Benin particularly in the district of Lalo. The availability of water as well as good hygiene are important for the management of Buruli ulcer particularly in the area of wound care one of the main component of the treatment of BU lesions. Given the growing importance of WASH in controlling NTDs and in order to assess the baseline for future cross-cutting interventions, we report here on the first study evaluating the level of WASH and associated factors in Lalo, one of the most BU-endemic districts in Benin. A cross-sectional study was carried to assess WASH practices and associated factors in the district of Lalo. Data were collected from 600 heads of household using structured pretested questionnaire and observations triangulated with qualitative information obtained from in-depth interviews of patients, care-givers and community members. Univariate and multivariate analysis were carried to determine the relationships between the potential associated factors and the sanitation as well as hygiene status. BU is an important conditions in the district of Lalo with 917 new cases detected from 2006 to 2012. More than 49 % of the household surveyed used unimproved water sources for their daily needs. Only 8.7 % of the investigated household had improved sanitation facilities at home and 9.7 % had improved hygiene behavior. The type of housing as an indicator of the socioeconomic status, the permanent availability of soap and improved hygiene practices were identified as the main factors positively associated with improved sanitation status. In the district of Lalo in Benin, one of the most endemic for BU, the WASH indicators are very low. This study provides baseline informations for future cross-cutting interventions in this district.

  14. Bounding the marginal cost of producing potable water including the use of seawater desalinization as a backstop potable water production technology

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, James J.

    2014-04-01

    The analysis presented in this technical report should allow for the creation of high, medium, and low cost potable water prices for GCAM. Seawater reverse osmosis (SWRO) based desalinization should act as a backstop for the cost of producing potable water (i.e., the literature seems clear that SWRO should establish an upper bound for the plant gate cost of producing potable water). Transporting water over significant distances and having to lift water to higher elevations to reach end-users can also have a significant impact on the cost of producing water. The three potable fresh water scenarios describe in this technical report are: low cost water scenario ($0.10/m3); medium water cost scenario ($1.00/m3); and high water cost scenario ($2.50/m3).

  15. Is drinking water a risk factor for endemic cryptosporidiosis? A case-control study in the immunocompetent general population of the San Francisco Bay Area

    Directory of Open Access Journals (Sweden)

    Nadle Joelle

    2003-03-01

    Full Text Available Abstract Background Cryptosporidiosis, caused by Cryptosporidium, is an enteric illness that has received much attention as an infection of immunocompromised persons as well as in community outbreaks (frequently waterborne. There are, however, no studies of the risk factors for sporadic community-acquired cryptosporidiosis in the immunocompetent US population. We undertook a case-control study in the San Francisco Bay Area as part of a national study sponsored by the Centers for Disease Control and Prevention to ascertain the major routes of transmission for endemic cryptosporidiosis, with an emphasis on evaluating risk from drinking water. Methods Cases were recruited from a population-based, active surveillance system and age-matched controls were recruited using sequential random-digit dialing. Cases (n = 26 and controls (n = 62 were interviewed by telephone using a standardized questionnaire that included information about the following exposures: drinking water, recreational water, food items, travel, animal contact, and person-to-person fecal contact, and (for adults sexual practices. Results In multivariate conditional logistic regression analyses no significant association with drinking water was detected. The major risk factor for cryptosporidiosis in the San Francisco Bay Area was travel to another country (matched odds ratio [95% confidence interval]: 24.1 [2.6, 220]. Conclusion The results of this study do not support the hypothesis that drinking water is an independent risk factor for cryptosporidiosis among the immunocompetent population. These findings should be used to design larger studies of endemic cryptosporidiosis to elucidate the precise mechanisms of transmission, whether waterborne or other.

  16. Longitudinal Household Trends in Access to Improved Water Sources and Sanitation in Chi Linh Town, Hai Duong Province, Viet Nam and Associated Factors.

    Science.gov (United States)

    Tuyet-Hanh, Tran Thi; Long, Tran Khanh; Van Minh, Hoang; Huong, Le Thi Thanh

    2016-01-01

    This study aims to characterize household trends in access to improved water sources and sanitaton in Chi Linh Town, Hai Duong Province, Vietnam, and to identify factors affecting those trends. Data were extracted from the Chi Linh Health and Demographic Surveillance System (CHILILAB HDSS) database from 2004-2014, which included household access to improved water sources, household access to improved sanitation, and household demographic data. Descriptive statistical analysis and multinominal logistic regression were used. The results showed that over a 10-year period (2004-2014), the proportion of households with access to improved water and improved sanitation increased by 3.7% and 28.3%, respectively. As such, the 2015 Millennium Development Goal targets for safe drinking water and basic sanitation were met. However, 13.5% of households still had unimproved water and sanitation. People who are retired, work in trade or services, or other occupations were 1.49, 1.97, and 1.34 times more likely to have access to improved water and sanitation facilities than farming households, respectively ( p < 0.001). Households living in urban areas were 1.84 times more likely than those living in rural areas to have access to improved water sources and improved sanitation facilities (OR =1.84; 95% CI = 1.73-1.96). Non-poor households were 2.12 times more likely to have access to improved water sources and improved sanitation facilities compared to the poor group (OR = 2.12; 95% CI = 2.00-2.25). More efforts are required to increase household access to both improved water and sanitation in Chi Linh Town, focusing on the 13.5% of households currently without access. Similar to situations observed elsewhere in Vietnam and other low- and middle- income countries, there is a need to address socio-economic factors that are associated with inadequate access to improved water sources and sanitation facilities.

  17. Forests and water cycle

    Directory of Open Access Journals (Sweden)

    Iovino F

    2009-06-01

    Full Text Available Based on a comprehensive literature analysis, a review on factors that control water cycle and water use in Mediterranean forest ecosystems is presented, including environmental variables and silvicultural treatments. This important issue is considered in the perspective of sustainable forest management of Mediterranean forests, with special regard to crucial environmental hazards such as forest fires and desertification risks related to climate change.

  18. STUDY ON THE FACTORS INFLUENCING HYDRATION AND WATER RETENTION CAPACITY OF MEAT

    Directory of Open Access Journals (Sweden)

    DANIELA IANIłCHI

    2008-10-01

    Full Text Available Top-quality food produce and high profitability in processing requires high quality in raw materials. Therefore, to achieve these objectives, it is imperative to know the properties of the war materials, and the factors that influence these properties.The properties of the meat directly involved in increasing economic efficiency and final produce quality are the so-called technological properties: hydration capacity and water retention capacity of meat. These properties are determined by some factors belonging to the intrinsic quality of meat, animal slaughter methods, technological operations applied to the meat, and the auxiliary materials used.

  19. A survey of perfluorinated compounds in surface water and biota including dolphins from the Ganges River and in other waterbodies in India

    Digital Repository Service at National Institute of Oceanography (India)

    Yeung, L.W.Y.; Yamashita, N.; Taniyasu, S.; Lam, P.K.S.; Sinha, R; Borole, D.V.; Kannan, K.

    and biomagnifications factors of PFCs were estimated in the Ganges River basin food web. The highest concentration of PFOA, 23.1 ng L sup(-1), was found in untreated sewage samples. Overall, concentrations of PFCs of water and biological samples from India are lower...

  20. Operational Water Withdrawal and Consumption Factors for Electricity Generation Technology in China—A Literature Review

    Directory of Open Access Journals (Sweden)

    Jinjing Gao

    2018-04-01

    Full Text Available As two indispensable resources for human development, energy and water are closely related. China, as the world’s largest consumer of electricity, is also experiencing very serious water shortages. Understanding the water consumption intensity in various types of electric power production technologies according to China’s national conditions is a prerequisite for understanding the potential impact of electrical power production on water resources. Therefore, following the steps of a meta-analysis, this paper provides a literature review on operational water withdrawal and consumption factors for electricity generation technology in China. We observed that 50% of water consumption for electricity generation was for coal power, whereas there was no research on the water consumption intensity of natural gas power generation, and a shortage of studies on water intake during electrical power production. The average water consumption intensity of hydropower is the largest. The results indicate that compared with other fuel types, hydropower is not a sustainable energy with respect to water conservation, and the study of hydropower applications should be improved in China.

  1. The agronomic science of spatial and temporal water management:How much, when and where

    Science.gov (United States)

    The agronomic sciences are those that are applied to soil and water management and crop production, including soil, water and plant sciences and related disciplines. The science of spatial and temporal water management includes many agronomic science factors, including soil physics, biophysics, plan...

  2. Temporal Variations of Water Productivity in Irrigated Corn: An Analysis of Factors Influencing Yield and Water Use across Central Nebraska.

    Directory of Open Access Journals (Sweden)

    Tony Carr

    Full Text Available Water Productivity (WP of a crop defines the relationship between the economic or physical yield of the crop and its water use. With this concept it is possible to identify disproportionate water use or water-limited yield gaps and thereby support improvements in agricultural water management. However, too often important qualitative and quantitative environmental factors are not part of a WP analysis and therefore neglect the aspect of maintaining a sustainable agricultural system. In this study, we examine both the physical and economic WP in perspective with temporally changing environmental conditions. The physical WP analysis was performed by comparing simulated maximum attainable corn yields per unit of water using the crop model Hybrid-Maize with observed data from 2005 through 2013 from 108 farm plots in the Central Platte and the Tri Basin Natural Resource Districts of Nebraska. In order to expand the WP analysis on external factors influencing yields, a second model, Maize-N, was used to estimate optimal nitrogen (N-fertilizer rate for specific fields in the study area. Finally, a vadose zone flow and transport model, HYDRUS-1D for simulating vertical nutrient transport in the soil, was used to estimate locations of nitrogen pulses in the soil profile. The comparison of simulated and observed data revealed that WP was not on an optimal level, mainly due to large amounts of irrigation used in the study area. The further analysis illustrated year-to-year variations of WP during the nine consecutive years, as well as the need to improve fertilizer management to favor WP and environmental quality. In addition, we addressed the negative influence of groundwater depletion on the economic WP through increasing pumping costs. In summary, this study demonstrated that involving temporal variations of WP as well as associated environmental and economic issues can represent a bigger picture of WP that can help to create incentives to sustainably

  3. Water Intensity of Electricity from Geothermal Resources

    Science.gov (United States)

    Mishra, G. S.; Glassley, W. E.

    2010-12-01

    BACKGROUND Electricity from geothermal resources could play a significant role in the United States over the next few decades; a 2006 study by MIT expects a capacity of 100GWe by 2050 as feasible; approximately 10% of total electricity generating capacity up from less than 1% today. However, there is limited research on the water requirements and impacts of generating electricity from geothermal resources - conventional as well as enhanced. To the best of our knowledge, there is no baseline exists for water requirements of geothermal electricity. Water is primarily required for cooling and dissipation of waste heat in the power plants, and to account for fluid losses during heat mining of enhanced geothermal resources. MODEL DESCRIPTION We have developed a model to assess and characterize water requirements of electricity from hydrothermal resources and enhanced geothermal resources (EGS). Our model also considers a host of factors that influence cooling water requirements ; these include the temperature and chemical composition of geothermal resource; installed power generation technology - flash, organic rankine cycle and the various configurations of these technologies; cooling technologies including air cooled condensers, wet recirculating cooling, and hybrid cooling; and finally water treatment and recycling installations. We expect to identify critical factors and technologies. Requirements for freshwater, degraded water and geothermal fluid are separately estimated. METHODOLOGY We have adopted a lifecycle analysis perspective that estimates water consumption at the goethermal field and power plant, and accounts for transmission and distribution losses before reaching the end user. Our model depends upon an extensive literature review to determine various relationships necessary to determine water usage - for example relationship between thermal efficiency and temperature of a binary power plant, or differences in efficiency between various ORC configurations

  4. Characteristics of water obtained by dewatering cyanobacteria-containing sludge formed during drinking water treatment, including C-, N-disinfection byproduct formation.

    Science.gov (United States)

    Xu, Hangzhou; Pei, Haiyan; Jin, Yan; Xiao, Hongdi; Ma, Chunxia; Sun, Jiongming; Li, Hongmin

    2017-03-15

    This is the first study to systematically investigate the characteristics of the water obtained by dewatering cyanobacteria-containing sludge generated in the drinking water treatment plant, including formation of C- and N-disinfection by-products (DBPs). Results showed that this 'dewatering water' (DW) had different properties when the sludge was stored at different times. The content of dissolved organic matter (DOM) and microcystins (MCs) in the DW were low when the sludge was treated or disposed of within 4 days; correspondingly, the C-, N-DBP production was also low. However, due to the damage of algal cells to some extent, the DOM and MC levels increased significantly for storage time longer than 4 days; the production of C-, N-DBPs also increased. There were also obvious differences in the characteristics of the DW from sludges generated with different coagulant species. Due to the better protective effect of FeCl 3 and polymeric aluminium ferric chloride (PAFC) flocs, the DOM and MC levels and the production of C-, N-DBPs in the DW with FeCl 3 and PAFC coagulation were lower than those with AlCl 3 coagulation, even though the sludges were stored for the same amount of time. Furthermore, because of the formation of Al and Fe hydroxides, precipitated onto the surface of flocs, the soluble Al and Fe in the DW decreased with increased storage time, especially in the first four days. Overall, this study revealed the trends in variation of DW quality for cyanobacteria-containing sludges formed with different coagulants, then FeCl 3 and PAFC coagulants are recommended and sludge should be treated or disposed of within 4 days. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Calculation of Buildup Factor for Gamma-ray Exposure in Two Layered Shields Made of Water and Lead

    International Nuclear Information System (INIS)

    Al-Saadi, A.H.

    2012-01-01

    The buildup factor for gamma ray exposure is most useful in calculations for biological protective shields.The buildup factors for gamma ray exposure were calculated in tow layered shields consist of water-lead and lead-water up to optical Thickness 20 mean free path (mfp) at gamma ray energies 1, 2 and 6MeV by using kalos's formula.The program has been designed to work at any atomic number of the attenuating medium, photon energy, slab thickness and and the arrangement of materials.The results obtained in this search leading to the buildup factor for gamma ray exposure at energies (1and2MeV) in lead-water were higher than the reverse case,while at energy 6 MeV the effect was opposite.The calculated data were parameterized by an empirical formula as a function of optical thickness of tow materials.The results obtained were in reasonable agreement with a previous work

  6. Water Quality Drivers in 11 Gulf of Mexico Estuaries

    OpenAIRE

    Matthew J. McCarthy; Daniel B. Otis; Pablo Méndez-Lázaro; Frank E. Muller-Karger

    2018-01-01

    Coastal water-quality is both a primary driver and also a consequence of coastal ecosystem health. Turbidity, a measure of dissolved and particulate water-quality matter, is a proxy for water quality, and varies on daily to interannual periods. Turbidity is influenced by a variety of factors, including algal particles, colored dissolved organic matter, and suspended sediments. Identifying which factors drive trends and extreme events in turbidity in an estuary helps environmental managers and...

  7. Factors influencing the performance and efficiency of solar water pumping systems:  a review

    OpenAIRE

    Gouws, Rupert; Lukhwareni, Thendo

    2012-01-01

    The world is having an energy crisis and currently there is a strong drive towards renewable energy. A renewable energy option is solar energy, where by means of photovoltaic (PV) modules electrical energy can be produced. A residential as well as industrial application for these PV modules is solar water pumping systems. Disadvantages of solar water pumping systems are low performance and low energy efficiency. This paper provides a review on the factors that influence the performance and ef...

  8. Water management for development of water quality in the Ruhr River basin.

    Science.gov (United States)

    Klopp, R

    2000-01-01

    On the Ruhr, a small river running through hilly country and with a mean flow of 76 m3/s, 27 water works use the method of artificial groundwater recharge to produce 350 million m3 of drinking water annually. On the basis of a special act, the Ruhr River Association is responsible for water quality and water quantity management in the Ruhr basin. The present 94 municipal sewage treatment plants ensure that the raw water is sufficiently good to be turned into drinking water. In the Ruhr's lower reaches, where dry weather results in a 20% share of the entire water flow being treated wastewater, comparatively high concentration of substances of domestic or industrial origin are likely, including substances which municipal wastewater treatment measures cannot entirely remove. These substances include ammonium, coliform bacteria or pathogens, boron and organic trace substances. Although water treatment measures have greatly contributed to the considerable improvement of the Ruhr's water quality in the last few decades, it is desirable to continue to aim at a high standard of drinking water production technologies since the Ruhr is a surface water body influenced by anthropogenic factors. However, in the case of substances infiltrating into drinking water, legislation is required if a reduction of pollution appears to be necessary.

  9. Biogen water of the Irtysh river - the principal population health factor suffered from the nuclear test on the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Inyushin, V.M.; Yurenkov, V.V.

    2001-01-01

    Authors notes, that Semipalatinsk test site activity together with other factors changes a water quality. The principal consequence of nuclear tests is build up in new cells by the 'pathogenous' water in plants, animals and human . 'Pathogenous water' is generating at steady changes of electronic strictures (spin performances) at ionizing radiation effect, radionuclides and other factors of nuclear explosions. These factors were did not known to a world-wide science. The second of very important phenomenon of nuclear explosions consequences at the Semipalatinsk test site is reduce of the hydro-plasma in the water sources the Irtysh River basin. This was proved with direct studies microcurrents density in the water as well as analysis of electronic and ionic structures with the plasma-graphic help. The water having the pathogenous memory - building up in the cells - reduces the immune status, negatively reflects on the vital functions, decreasing the resistance to unfavorable effects. It is offered for remediation of the 'pathogenous water' to use the bio-genized water as most adequate one to endogenous water of living cells. Mass usage of the bio-genized water takes out genetic consequences of nuclear explosions and increase of an immunity level. The 'Bio-genization' of the Irtysh River water is concludes a few stages

  10. Analysis of Environmental Physical-Chemical Factors and Macroalga Species In The Coastal Water of Nusalaut, Central Maluku - Indonesia

    Directory of Open Access Journals (Sweden)

    Karel Melsasail

    2018-03-01

    Full Text Available The physical-chemical factors of environment are very influential on the presence and the growth of macrolaga in waters. Well-maintained water habitat is a good environment for the growth of macroalgae. A research has been conducted on the physicochemical environmental factors and the macroalgae species in the coastal waters of Nusalaut Island using transect method, and it was a survey research on four different observation stations. The results of the research showed that station I (Amet Village has the best physicochemical factors for the presence and the growth of macroalgae, compared to station II (Nalahia Village, station III (Sila Village and station IV (Leinitu Village. The most widely found macro algae are from the Rhodophyta class, with a total of 17 species of macroalgae, of which 15 species are found in station I.

  11. Water Use Efficiency and Its Influencing Factors in China: Based on the Data Envelopment Analysis (DEA—Tobit Model

    Directory of Open Access Journals (Sweden)

    Shuqiao Wang

    2018-06-01

    Full Text Available Water resources are important and irreplaceable natural and economic resources. Achieving a balance between economic prosperity and protection of water resource environments is a major issue in China. This article develops a data envelopment analysis (DEA approach with undesirable outputs by using Seiford’s linear converting method to estimate water use efficiencies for 30 provinces in China, from 2008–2016,and then analyzes the influencing factors while using a DEA-Tobit model. The findings show that the overall water use efficiency of the measured Chinese provinces, when considering sewage emissions as the undesirable output, is 0.582. Thus, most regions still need improvement. Provinces with the highest water efficiency are located in economically developed Eastern China. The spatial pattern of water use efficiency in China is consistent with the general pattern of regional economic development. This study implies that factors like export dependence, technical progress, and educational value have a positive influence on water use efficiency. Further, while industrial structure has had a negative impact, government intervention has had little impact on water use efficiency. These research results will provide a scientific basis for the government to make plans for water resource development, and it may be helpful in improving regional sustainable development.

  12. How propeller suction is the dominant factor for ship accidents at shallow water conditions

    Science.gov (United States)

    Acar, Dursun; Alpar, Bedri; Ozeren, Sinan

    2017-04-01

    The laminar flow comes to the fore with the disappearance of the several other directions in the internal displacements in the water current. Due to the dominant speed direction during the straightforward motion of the ship, the underwater hull is associated with the continuous flow of laminar currents. The open marine environment acts as a compressible liquid medium because of the presence of many variables about water volume overflow boundaries where the ship is associated. Layers of water rising over the sea surface due to ship's body and the propeller's water push provides loss of liquid lifting force for the ship. These situations change the well-known sea-floor morphology and reliable depth limits, and lead to probable accidents. If the ship block coefficient for the front side is 0.7 or higher, the "squat" will be more on the bow, because the associated factor "displacement volume" causes to the low-pressure environment due to large and rapid turbulence. Thus, the bow sinks further, which faced with liquid's weaker lift force. The vessels Gerardus Mercator, Queen Elizabeth and Costa Concordia had accidents because of unified reasons of squat, fast water mass displacement by hull push and propeller suction interaction. In the case of water mass displacement from the bow side away, that accident occurred in 2005 by the vessel Gerardus Mercator with excessive longitudinal trim angularity in the shallow water. The vessel Costa Concordia (2012), voluminous water displaced from the rear left side was an important factor because of the sharp manoeuvre of that the captain made before the accident. Observations before the accident indicate that full-speed sharp turn provided listed position for the ship from left (port side) in the direction of travel before colliding and then strike a rock on the sloping side of the seabed. The reason why the ship drifted to the left depends mainly the water discharge occurred at the left side of the hull during left-hand rudder

  13. Environmental setting and natural factors and human influences affecting water quality in the White River Basin, Indiana

    Science.gov (United States)

    Schnoebelen, Douglas J.; Fenelon, Joseph M.; Baker, Nancy T.; Martin, Jeffrey D.; Bayless, E. Randall; Jacques, David V.; Crawford, Charles G.

    1999-01-01

    The White River Basin drains 11,349 square miles of central and southern Indiana and is one of 59 Study Units selected for water-quality assessment as part of the U.S. Geological Survey's National WaterQuality Assessment Program. Defining the environmental setting of the basin and identifying the natural factors and human influences that affect water quality are important parts of the assessment.

  14. Higher Anti-Liver Fibrosis Effect of Cordyceps militaris-Fermented Product Cultured with Deep Ocean Water via Inhibiting Proinflammatory Factors and Fibrosis-Related Factors Expressions

    Directory of Open Access Journals (Sweden)

    Yu-Ping Hung

    2017-06-01

    Full Text Available Deep ocean water (DOW has been shown to enhance the functional components of fungi, resulting in increased health benefits. Therefore, using DOW for culturing fungi can enhance the cordycepin and adenosine of Cordyceps militaris (CM and its protective effects on the liver. In this study, the antiliver fibrosis effects and mechanisms of ultrapure water-cultured CM (UCM, DOW-cultured CM (DCM, synthetic water-cultured CM, DOW, cordycepin, and adenosine were compared in the liver fibrosis mice induced by intraperitoneal injections of thioacetamide (TAA. The results indicated that DCM exhibited superior performance in reducing liver collagen accumulation, mitigating liver injuries, inhibiting proinflammatory factors and fibrosis-related factor (TGF-β1, Smad2/3, α-SMA, COL1A1 expression compared with UCM. DOW, cordycepin, and adenosine also performed antiliver fibrosis effect. Therefore, because DCM is rich in DOW and functional components, it can achieve anti-liver fibrosis effects through multiple pathways. These ameliorative effects are considerably superior to those of UCM.

  15. Higher Anti-Liver Fibrosis Effect of Cordyceps militaris-Fermented Product Cultured with Deep Ocean Water via Inhibiting Proinflammatory Factors and Fibrosis-Related Factors Expressions.

    Science.gov (United States)

    Hung, Yu-Ping; Lee, Chun-Lin

    2017-06-08

    Deep ocean water (DOW) has been shown to enhance the functional components of fungi, resulting in increased health benefits. Therefore, using DOW for culturing fungi can enhance the cordycepin and adenosine of Cordyceps militaris (CM) and its protective effects on the liver. In this study, the antiliver fibrosis effects and mechanisms of ultrapure water-cultured CM (UCM), DOW-cultured CM (DCM), synthetic water-cultured CM, DOW, cordycepin, and adenosine were compared in the liver fibrosis mice induced by intraperitoneal injections of thioacetamide (TAA). The results indicated that DCM exhibited superior performance in reducing liver collagen accumulation, mitigating liver injuries, inhibiting proinflammatory factors and fibrosis-related factor (TGF-β1, Smad2/3, α-SMA, COL1A1) expression compared with UCM. DOW, cordycepin, and adenosine also performed antiliver fibrosis effect. Therefore, because DCM is rich in DOW and functional components, it can achieve anti-liver fibrosis effects through multiple pathways. These ameliorative effects are considerably superior to those of UCM.

  16. Part of corrosion factor in metal cavitation-erosion failure in fresh waters

    International Nuclear Information System (INIS)

    Ehdel', Yu.U.; Khaldeev, G.V.; Kichigin, V.I.; Pylaev, N.I.; Kuznetsov, V.V.

    1979-01-01

    Presented are the results of the study of the variation of the structure and of the electrochemical characteristics of the surface layer of a silicon-bearing iron and of 1Kh18N9T steel, immersed in fresh water, as a function of the intensity of a cavitation-erosion treatment. This treatment increases the rate of corrosion of the metal in fresh water, a growth in the mineralization of water enhancing the effect. Metallographic studies have shown that the most characteristic type of disintegration is the formation of pits on the metallic surface the distribution and the structure of which are governed by the microplastic deformation occurring in the cavitation work-hardening. A quantitative evaluation indicates that the ratio of the corrosion and the mechanical factors in the cavitation-erosion process depends not only on the intensity of the cavitation action, but also on the nature of the metal and its tendency to passivate

  17. The Effect of Landuse and Other External Factors on Water Quality Within two Creeks in Northern Kentucky

    Science.gov (United States)

    Boateng, S.

    2006-05-01

    The purpose of this study was to monitor the water quality in two creeks in Northern Kentucky. These are the Banklick Creek in Kenton County and the Woolper Creek in Boone County, Kentucky. The objective was to evaluate the effect of landuse and other external factors on surface water quality. Landuse within the Banklick watershed is industrial, forest and residential (urban) whereas that of Woolper Creek is agricultural and residential (rural). Two testing sites were selected along the Banklick Creek; one site was upstream the confluence with an overflow stream from an adjacent lake; the second site was downstream the confluence. Most of the drainage into the lake is over a near-by industrial park and the urban residential areas of the cities of Elsmere and Erlanger, Kentucky. Four sampling locations were selected within the Woolper Creek watershed to evaluate the effect of channelization and subsequent sedimentation on the health of the creek. Water quality parameters tested for include dissolved oxygen, phosphates, chlorophyll, total suspended sediments (TSS), pH, oxidation reduction potential (ORP), nitrates, and electrical conductivity. Sampling and testing were conducted weekly and also immediately after storm events that occurred before the regular sampling dates. Sampling and testing proceeded over a period of 29 weeks. Biological impact was determined, only in Woolper Creek watershed, by sampling benthic macroinvertebrates once every four weeks. The results showed significant differences in the water quality between the two sites within the Banklick Creek. The water quality may be affected by the stream overflow from the dammed lake. Also, channelization in the Woolper Creek seemed to have adverse effects on the water quality. A retention pond, constructed to prevent sediments from flowing into the Woolper Creek, did not seem to be effective. This is because the water quality downstream of the retention pond was significantly worse than that of the

  18. Factors Influencing Water Resource Governance among Pastoral Community at Mkondoa Sub-Catchment Morogoro Region Tanzania

    OpenAIRE

    Yeremia Yohana Masifia; Sarone Ole Sena

    2017-01-01

    The importance of proper Water Resource Management with greater emphasis on ensuring sustainability quality accountability and community participation has become imminent as water resources increasingly become scarce Harvey et al 2007. Water resources management in Tanzania is governed under the National Water Policy of 2002 and Water Resources Management Act No.11 of year 2009. Other related legislations include Environmental Management Act No. 20 of year 2004 Forest Policy and Forest Act No...

  19. Analysis of algae growth mechanism and water bloom prediction under the effect of multi-affecting factor.

    Science.gov (United States)

    Wang, Li; Wang, Xiaoyi; Jin, Xuebo; Xu, Jiping; Zhang, Huiyan; Yu, Jiabin; Sun, Qian; Gao, Chong; Wang, Lingbin

    2017-03-01

    The formation process of algae is described inaccurately and water blooms are predicted with a low precision by current methods. In this paper, chemical mechanism of algae growth is analyzed, and a correlation analysis of chlorophyll-a and algal density is conducted by chemical measurement. Taking into account the influence of multi-factors on algae growth and water blooms, the comprehensive prediction method combined with multivariate time series and intelligent model is put forward in this paper. Firstly, through the process of photosynthesis, the main factors that affect the reproduction of the algae are analyzed. A compensation prediction method of multivariate time series analysis based on neural network and Support Vector Machine has been put forward which is combined with Kernel Principal Component Analysis to deal with dimension reduction of the influence factors of blooms. Then, Genetic Algorithm is applied to improve the generalization ability of the BP network and Least Squares Support Vector Machine. Experimental results show that this method could better compensate the prediction model of multivariate time series analysis which is an effective way to improve the description accuracy of algae growth and prediction precision of water blooms.

  20. Consumption of Water for Household Needs and the Affecting Factors at Banyudono Boyolali

    Directory of Open Access Journals (Sweden)

    Alif Noor Anna

    2004-01-01

    Full Text Available The consumption of drinking water for a community is different from one area to the other. This is normally influenced by the population development, socio-economic, cultural, and physical conditions mainly related to the supply of drinking water and how to exploit it. Banyudono district is an area located in the regency of Boyolali. The development of this area depends on Boyolali City and Kartasura district. Such a location enables the area to have a process of the physical and socio-economi developments. In addition, it has an influence upon social behaviour to consume water. This research is aimed at knowing the average consumption of household need and analyzing the factors influencing the utilization of water as drinking water. The result of this research indicated that 1 the average consumption of a human being for drinking water was 79,37 litter a day. It means that the onsumption of a human being for drinking ater generally ranged from 60 to 80 litter a day; 2 most of the ater was consumed to meet basic needs such as cooking, drinking, bathing, and washing; 3 the difference of the average consumption was influenced by the kind of water source and how to exploit it; 4 a parameter of the most significant socio-economic condition that took effect on the average consumption for drinking water was the parameter of income with correlation of 0.362 and the significant level of 0.01.

  1. Applying of Factor Analyses for Determination of Trace Elements Distribution in Water from River Vardar and Its Tributaries, Macedonia/Greece

    Science.gov (United States)

    Popov, Stanko Ilić; Stafilov, Trajče; Šajn, Robert; Tănăselia, Claudiu; Bačeva, Katerina

    2014-01-01

    A systematic study was carried out to investigate the distribution of fifty-six elements in the water samples from river Vardar (Republic of Macedonia and Greece) and its major tributaries. The samples were collected from 27 sampling sites. Analyses were performed by mass spectrometry with inductively coupled plasma (ICP-MS) and atomic emission spectrometry with inductively coupled plasma (ICP-AES). Cluster and R mode factor analysis (FA) was used to identify and characterise element associations and four associations of elements were determined by the method of multivariate statistics. Three factors represent the associations of elements that occur in the river water naturally while Factor 3 represents an anthropogenic association of the elements (Cd, Ga, In, Pb, Re, Tl, Cu, and Zn) introduced in the river waters from the waste waters from the mining and metallurgical activities in the country. PMID:24587756

  2. Applying of Factor Analyses for Determination of Trace Elements Distribution in Water from River Vardar and Its Tributaries, Macedonia/Greece

    Directory of Open Access Journals (Sweden)

    Stanko Ilić Popov

    2014-01-01

    Full Text Available A systematic study was carried out to investigate the distribution of fifty-six elements in the water samples from river Vardar (Republic of Macedonia and Greece and its major tributaries. The samples were collected from 27 sampling sites. Analyses were performed by mass spectrometry with inductively coupled plasma (ICP-MS and atomic emission spectrometry with inductively coupled plasma (ICP-AES. Cluster and R mode factor analysis (FA was used to identify and characterise element associations and four associations of elements were determined by the method of multivariate statistics. Three factors represent the associations of elements that occur in the river water naturally while Factor 3 represents an anthropogenic association of the elements (Cd, Ga, In, Pb, Re, Tl, Cu, and Zn introduced in the river waters from the waste waters from the mining and metallurgical activities in the country.

  3. Factores psicosociales relacionados con el consumo doméstico de agua en una región semidesértica Psychosocial factors associated with domestic water consumption in a semidesert region

    Directory of Open Access Journals (Sweden)

    Rocío Haydee Arreguín-Moreno

    2009-08-01

    Full Text Available OBJETIVO: Analizar los factores psicosociales que intervienen en el consumo doméstico del agua en Hermosillo, Sonora, región del noroeste de México caracterizada por ser semidesértica. Para ello se trabajó con una muestra seleccionada de forma intencional de 198 personas (79 hombres y 119 mujeres de una institución de educación superior, con base en las teorías de la acción razonada y la autoeficacia. MATERIAL Y MÉTODOS: Se aplicó una escala que incluyó los factores psicosociales analizados, con opciones tipo Likert. RESULTADOS: La media de edad fue de 35 años. La relación entre los factores fue positiva y moderada, en particular entre intención-norma, creencias-intención, creencias-autoeficacia, actitud-intención, actitud-autoeficacia y autoeficacia-intención. CONCLUSIÓN: Si bien las características de la muestra no permiten generalizar resultados, el estudio muestra la utilidad de los factores psicosociales analizados y sugiere la posibilidad de incorporarlos en programas educativos para el cuidado del agua en el hogar.OBJECTIVE: To analyze psychosocial factors related with domestic water consumption in Hermosillo, Sonora, a semidesert region in northwestern Mexico. An intentionally selected sample of 198 people (79 men and 119 women from a higher education institution was used to evaluate the theories of rational action and self-efficacy. MATERIAL AND METHODS: A scale with the psychosocial factors to be analyzed and Likert-type items was applied. RESULTS: The age mean was 35 years old. A positive moderate association was found between the diverse factors, particularly between intention-norm, beliefs-intention, beliefs-self-efficacy, attitude-intention, attitude-self-efficacy, and self-efficacy-intention. CONCLUSIONS: Despite the fact that the sample characteristics do not allow results to be generalized, the study shows the usefulness of the psychosocial factors that were analyzed and suggests the possibility of including

  4. Analysis of Influencing Factors of Water Footprint Based on the STIRPAT Model: Evidence from the Beijing Agricultural Sector

    Directory of Open Access Journals (Sweden)

    Chen Jin

    2016-11-01

    Full Text Available Beijing suffers from a severe water shortage. To find the key factors that impact the agricultural water footprint (WF within Beijing to relieve the pressure on water resources, this study quantifies the agricultural WF within Beijing from 1980 to 2012 and examines the factors of population, urbanization level, GDP per capita, Engel coefficient, and total rural power using an extended stochastic impact by regression on population, affluence and technology (STIRPAT model. Ridge regression is employed to fit the extended STIRPAT model. The empirical results reveal that the Engel coefficient, which is defined as the total amount of food expenses accounted for the proportion of total personal consumption expenditures, has the largest positive impact on the increase in the agricultural WF, followed by urbanization. In contrast, total rural power, population, and GDP per capita can decrease the agricultural WF. Finally, policy recommendations from technological development, agriculture plantation structure adjustment, and virtual water imports are provided to cope with water shortages.

  5. Effects of Temperature and Growing Seasons on Crop Water ...

    African Journals Online (AJOL)

    PROF HORSFALL

    The crop water requirement (CWR) depends on several factors including temperature and ...... infrastructure for collection, treatment and recycling of wastewater (MOEP, 2010 .... blue and grey water footprint of crops and derived crop products ...

  6. Improvement of the including sink material for around steel pot hot water department; Yokoka yuataribuyo nagashikomizai no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Hakiwara, R.

    1999-02-01

    As for life of steel pot, there are many rates which a place hit part occupies even in some copies. How to construct the castable which was different from other parts was examined, and it worked for high durability performance only around the hot water hit city for that. It worked for the life extension by this report to prevent spool for which to be a main damage factor thunder big fault grains were increased it was added .20% of the durability improvement could be confirmed so far more than goods as that result by adding big fault grain 40%. (translated by NEDO)

  7. Water-Related Power Plant Curtailments: An Overview of Incidents and Contributing Factors

    Energy Technology Data Exchange (ETDEWEB)

    McCall, James [National Renewable Energy Lab. (NREL), Golden, CO (United States); Macknick, Jordan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Macknick, Jordan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-12-01

    Water temperatures and water availability can affect the reliable operations of power plants in the United States. Data on water-related impacts on the energy sector are not consolidated and are reported by multiple agencies. This study provides an overview of historical incidents where water resources have affected power plant operations, discusses the various data sources providing information, and creates a publicly available and open access database that contains consolidated information about water-related power plant curtailment and shut-down incidents. Power plants can be affected by water resources if incoming water temperatures are too high, water discharge temperatures are too high, or if there is not enough water available to operate. Changes in climate have the potential to exacerbate uncertainty over water resource availability and temperature. Power plant impacts from water resources include curtailment of generation, plant shut-downs, and requests for regulatory variances. In addition, many power plants have developed adaptation approaches to reducing the potential risks of water-related issues by investing in new technologies or developing and implementing plans to undertake during droughts or heatwaves. This study identifies 42 incidents of water-related power plant issues from 2000-2015, drawing from a variety of different datasets. These incidents occur throughout the U.S., and affect coal and nuclear plants that use once-through, recirculating, and pond cooling systems. In addition, water temperature violations reported to the Environmental Protection Agency are also considered, with 35 temperature violations noted from 2012-2015. In addition to providing some background information on incidents, this effort has also created an open access database on the Open Energy Information platform that contains information about water-related power plant issues that can be updated by users.

  8. Integrated Water Basin Management Including a Large Pit Lake and a Water Supply Reservoir: The Mero-Barcés Basin

    Science.gov (United States)

    Delgado, Jordi; Juncosa-Rivera, Ricardo; Hernández-Anguiano, Horacio; Muñoz-Ibáñez, Andrea

    2016-04-01

    Water resource managers attempt to minimize conflicts among users, preserve the environment as much as possible, and satisfy user necessities at a minimum cost. Several European directives indirectly address mine restoration policies, with a goal of minimizing negative impacts and adding social and environmental value where possible. Water management must consider water sources, ecological flows, flood control, and variability in the demands for urban, industrial, and agricultural uses. In the context of the present study, the city of A Coruña is located in Galicia (NW Spain). The water supply system for this city and surrounding municipalities (~400.000 inhabitants) is based on the Abegondo-Cecebre reservoir. In cases when precipitation is scarce (e.g. no rain for more than seven consecutive months) and there is a seasonal increase in demand significantly stress the supply system so that, as occurred in 2010, shortages and water supply restrictions need to be considered. This is a clear indication of that, at present, the Abegondo-Cecebre reservoir has not enough capacity to cope with a scenario of increasing water demand (due to the vegetative and seasonal increase of population) and hydric stress likely connected with the widely acknowledged climate change. In the present context of monetary resources scarcity and society concern with respect large new public work projects, the construction of a new dam is challenging. However the opportunity provided by the recent flooding of the Meirama open pit (a large mine void that has been forced-flooded for its reclamation and it is located in the headwaters of one of the rivers draining towards the Abegondo-Cecebre reservoir) proves to be a significant new asset that will help to improve the future water management scenarios under the acknowledged uncertain conditions. In this study we have studied in detail the hydrochemistry of the affected systems (lake, river and reservoir) in order to make clear whether or not the

  9. The calculation of relative output factor and depth dose for irregular electron fields in water

    International Nuclear Information System (INIS)

    Dunscombe, Peter; McGhee, Peter; Chu, Terence

    1996-01-01

    Purpose: A technique, based on sector integration and interpolation, has been developed for the computation of both relative output factor and depth dose of irregular electron fields in water. The purpose of this study was to determine the minimum experimental data set required for the technique to yield results within accepted dosimetric tolerances. Materials and Methods: PC based software has been written to perform the calculations necessary to dosimetrically characterize irregular shaped electron fields. The field outline is entered via digitiser and the SSD and energy via the keyboard. The irregular field is segmented into sectors of specified angle (2 deg. was used for this study) and the radius of each sector computed. The central ray depth dose is reconstructed by summing the contributions from each sector deduced from calibration depth doses measured for circular fields. Relative output factors and depth doses at SSDs at which calibrations were not performed are found by interpolation. Calibration data were measured for circular fields from 2 to 9 cm diameter at 100, 105, 110, and 115 cm SSD. A clinical cut out can be characterized in less than 2 minutes including entry of the outline using this software. The performance of the technique was evaluated by comparing calculated relative output factors, surface dose and the locations of d 80 , d 50 and d 20 with experimental measurements on a variety of cut out shapes at 9 and 18 MeV. The calibration data set (derived from circular cut outs) was systematically reduced to identify the minimum required to yield an accuracy consistent with current recommendations. Results: The figure illustrates the ability of the technique to calculate the depth dose for an irregular field (shown in the insert). It was found that to achieve an accuracy of 2% in relative output factor and 2% or 2 mm (our criterion) in percentage depth dose, calibration data from five circular fields at the four SSDs spanning the range 100-115 cm

  10. Shallow water table effects on water, sediment, and pesticide transport in vegetative filter strips - Part 2: model coupling, application, factor importance, and uncertainty

    Science.gov (United States)

    Lauvernet, Claire; Muñoz-Carpena, Rafael

    2018-01-01

    Vegetative filter strips are often used for protecting surface waters from pollution transferred by surface runoff in agricultural watersheds. In Europe, they are often prescribed along the stream banks, where a seasonal shallow water table (WT) could decrease the buffer zone efficiency. In spite of this potentially important effect, there are no systematic experimental or theoretical studies on the effect of this soil boundary condition on the VFS efficiency. In the companion paper (Muñoz-Carpena et al., 2018), we developed a physically based numerical algorithm (SWINGO) that allows the representation of soil infiltration with a shallow water table. Here we present the dynamic coupling of SWINGO with VFSMOD, an overland flow and transport mathematical model to study the WT influence on VFS efficiency in terms of reductions of overland flow, sediment, and pesticide transport. This new version of VFSMOD was applied to two contrasted benchmark field studies in France (sandy-loam soil in a Mediterranean semicontinental climate, and silty clay in a temperate oceanic climate), where limited testing of the model with field data on one of the sites showed promising results. The application showed that for the conditions of the studies, VFS efficiency decreases markedly when the water table is 0 to 1.5 m from the surface. In order to evaluate the relative importance of WT among other input factors controlling VFS efficiency, global sensitivity and uncertainty analysis (GSA) was applied on the benchmark studies. The most important factors found for VFS overland flow reduction were saturated hydraulic conductivity and WT depth, added to sediment characteristics and VFS dimensions for sediment and pesticide reductions. The relative importance of WT varied as a function of soil type (most important at the silty-clay soil) and hydraulic loading (rainfall + incoming runoff) at each site. The presence of WT introduced more complex responses dominated by strong interactions in

  11. Factors leading to poor water sanitation hygiene among primary school going children in Chitungwiza

    Directory of Open Access Journals (Sweden)

    Blessing Dube

    2012-03-01

    Full Text Available Although the world has progressed in the area of water and sanitation, more than 2.3 billion people still live without access to sanitation facilities and some are unable to practice basic hygiene. Access to water and basic sanitation has deteriorated in Chitungwiza and children are at risk of developing illness and missing school due to the deterioration. We sought to investigate the predisposing, enabling and reinforcing factors that are causally related to water- and sanitation- related hygiene practices among school going children. A random sample of 400 primary school children (196 males, 204 females in four schools in Chitungwiza town, Zimbabwe was interviewed. Behavioural factors were assessed through cross examination of the PROCEED PRECEDE Model. The respondents had been stratified through the random sampling where strata were classes. A structured observation checklist was also administered to assess hygiene enabling facilities for each school. Children’s knowledge and perceptions were inconsistent with hygienic behaviour. The family institution seemed to play a more important role in life skills training and positive reinforcement compared to the school (50% vs 27.3%. There was no association between a child’s sex, age and parents’ occupation with any of the factors assessed (P=0.646. Schools did not provide a hygiene enabling environment as there were no learning materials, policy and resources on hygiene and health. The challenges lay in the provision of hygiene enabling facilities, particularly, the lack of access to sanitation for the maturing girl child and a school curriculum that provides positive reinforcement and practical life skills training approach.

  12. An optical method to assess water clarity in coastal waters.

    Science.gov (United States)

    Kulshreshtha, Anuj; Shanmugam, Palanisamy

    2015-12-01

    Accurate estimation of water clarity in coastal regions is highly desired by various activities such as search and recovery operations, dredging and water quality monitoring. This study intends to develop a practical method for estimating water clarity based on a larger in situ dataset, which includes Secchi depth (Z sd ), turbidity, chlorophyll and optical properties from several field campaigns in turbid coastal waters. The Secchi depth parameter is found to closely vary with the concentration of suspended sediments, vertical diffuse attenuation coefficient K d (m(-1)) and beam attenuation coefficient c (m(-1)). The optical relationships obtained for the selected wavelengths (i.e. 520, 530 and 540 nm) exhibit an inverse relationship between Secchi depth and the length attenuation coefficient (1/(c + K d )). The variation in Secchi depth is expressed in terms of undetermined coupling coefficient which is composed of light penetration factor (expressed by z(1%)K d (λ)) and a correction factor (ξ) (essentially governed by turbidity of the water column). This method of estimating water clarity was validated using independent in situ data from turbid coastal waters, and its results were compared with those obtained from the existing methods. The statistical analysis of the measured and the estimated Z sd showed that the present method yields lower error when compared to the existing methods. The spatial structures of the measured and predicted Z sd are also highly consistent with in situ data, which indicates the potential of the present method for estimating the water clarity in turbid coastal and associated lagoon waters.

  13. Modeling a hierarchical structure of factors influencing exploitation policy for water distribution systems using ISM approach

    Science.gov (United States)

    Jasiulewicz-Kaczmarek, Małgorzata; Wyczółkowski, Ryszard; Gładysiak, Violetta

    2017-12-01

    Water distribution systems are one of the basic elements of contemporary technical infrastructure of urban and rural areas. It is a complex engineering system composed of transmission networks and auxiliary equipment (e.g. controllers, checkouts etc.), scattered territorially over a large area. From the water distribution system operation point of view, its basic features are: functional variability, resulting from the need to adjust the system to temporary fluctuations in demand for water and territorial dispersion. The main research questions are: What external factors should be taken into account when developing an effective water distribution policy? Does the size and nature of the water distribution system significantly affect the exploitation policy implemented? These questions have shaped the objectives of research and the method of research implementation.

  14. Exploring the Spatial-Seasonal Dynamics of Water Quality, Submerged Aquatic Plants and Their Influencing Factors in Different Areas of a Lake

    Directory of Open Access Journals (Sweden)

    Kun Li

    2017-09-01

    Full Text Available The degradation of water quality in lakes and its negative effects on freshwater ecosystems have become a serious problem worldwide. Exploring the dynamics in the associated factors is essential for water pollution management and control. GIS interpolation, principal component analysis (PCA and multivariate statistical techniques were used to identify the main pollution sources in different areas of Honghu Lake. The results indicate that the spatial distribution of the concentrations of total nitrogen (TN, total phosphate (TP, ammonia nitrogen (NH4+–N, and permanganate index (CODMn have similar characteristics and that their values gradually increased from south to north during the three seasons in Honghu Lake. The major influencing factors of water quality varied across the different areas and seasons. The relatively high concentrations of TN and TP, which might limit the growth of submerged aquatic plants, were mainly caused by anthropogenic factors. Our work suggests that spatial analyses combined with PCA are useful for investigating the factors that influence water quality and submerged aquatic plant biomass in different areas of a lake. These findings provide sound information for the future water quality management of the lake or even the entire lake basin.

  15. Temperature dependence of the calibration factor of radon and radium determination in water samples by SSNTD

    CERN Document Server

    Hunyadi, I; Hakl, J; Baradacs, E; Dezso, Z

    1999-01-01

    The sensitivity of a sup 2 sup 2 sup 6 Ra determination method of water samples by SSNTD was measured as a function of storage temperature during exposure. The method is based on an etched track type radon monitor, which is closed into a gas permeable foil and is immersed in the water sample. The sample is sealed in a glass vessel and stored for an exposure time of 10-30 days. The sensitivity increased more than a factor of two when the storage temperature was raised from 2 deg. C to 30 deg. C. Temperature dependence of the partition coefficient of radon between water and air provides explanation for this dependence. For practical radio- analytical application the temperature dependence of the calibration factor is given by fitting the sensitivity data obtained by measuring sup 2 sup 2 sup 6 Ra standard solutions (in the activity concentration range of 0.1-48.5 kBq m sup - sup 3) at different storage temperatures.

  16. Longitudinal Household Trends in Access to Improved Water Sources and Sanitation in Chi Linh Town, Hai Duong Province, Viet Nam and Associated Factors

    Directory of Open Access Journals (Sweden)

    Tran Thi Tuyet-Hanh

    2016-10-01

    Full Text Available Objective: This study aims to characterize household trends in access to improved water sources and sanitaton in Chi Linh Town, Hai Duong Province, Vietnam, and to identify factors affecting those trends. Method: Data were extracted from the Chi Linh Health and Demographic Surveillance System (CHILILAB HDSS database from 2004–2014, which included household access to improved water sources, household access to improved sanitation, and household demographic data. Descriptive statistical analysis and multinominal logistic regression were used. The results showed that over a 10-year period (2004–2014, the proportion of households with access to improved water and improved sanitation increased by 3.7% and 28.3%, respectively. As such, the 2015 Millennium Development Goal targets for safe drinking water and basic sanitation were met. However, 13.5% of households still had unimproved water and sanitation. People who are retired, work in trade or services, or other occupations were 1.49, 1.97, and 1.34 times more likely to have access to improved water and sanitation facilities than farming households, respectively (p < 0.001. Households living in urban areas were 1.84 times more likely than those living in rural areas to have access to improved water sources and improved sanitation facilities (OR =1.84; 95% CI = 1.73–1.96. Non-poor households were 2.12 times more likely to have access to improved water sources and improved sanitation facilities compared to the poor group (OR = 2.12; 95% CI = 2.00–2.25. More efforts are required to increase household access to both improved water and sanitation in Chi Linh Town, focusing on the 13.5% of households currently without access. Similar to situations observed elsewhere in Vietnam and other low- and middle- income countries, there is a need to address socio-economic factors that are associated with inadequate access to improved water sources and sanitation facilities.

  17. 75 FR 5317 - Exposure Factors Handbook: 2009 Update

    Science.gov (United States)

    2010-02-02

    ... chemicals. These factors include: Drinking water consumption; mouthing behavior; soil ingestion rates... document solely for the purpose of pre- dissemination peer review under applicable information quality... various factors used in assessing human exposure. This Handbook is aimed at exposure assessors inside the...

  18. Chemical composition of water from roofs in Gdansk, Poland

    International Nuclear Information System (INIS)

    Tsakovski, Stefan; Tobiszewski, Marek; Simeonov, Vasil; Polkowska, Zaneta; Namiesnik, Jacek

    2010-01-01

    This study deals with the assessment of roof runoff waters from the region of Gdansk collected during the winter season (2007/2008). The chemical analysis includes 16 chemical variables: major ions, PAHs and PCBs measured at 3 sampling sites for 6-14 rain events. Although the data set is of limited volume the statistical data treatment using self-organizing maps (SOM) reveals the main factors controlling roof runoff water quality even for a data set with small dimension. This effort for explanation of the identified factors by the possible emission sources of the urban environment and air-particulate formation seems to be very reliable. Additionally to the roof runoff water quality factors the rain events patterns are found: 'background' group of events and groups formally named 'PAHs', 'PCBs' and 'air-borne particles' - dominated events. The SOM classification results give an opportunity to uncover the role of roof 'impact' on the runoff waters. Rain runoff water quality is described by four latent factors and the 'roof' impact is uncovered. - Identification of the urban roof runoff water quality factors and 'roof' impact by self-organizing map classification.

  19. Accounting for Water Insecurity in Modeling Domestic Water Demand

    Science.gov (United States)

    Galaitsis, S. E.; Huber-lee, A. T.; Vogel, R. M.; Naumova, E.

    2013-12-01

    Water demand management uses price elasticity estimates to predict consumer demand in relation to water pricing changes, but studies have shown that many additional factors effect water consumption. Development scholars document the need for water security, however, much of the water security literature focuses on broad policies which can influence water demand. Previous domestic water demand studies have not considered how water security can affect a population's consumption behavior. This study is the first to model the influence of water insecurity on water demand. A subjective indicator scale measuring water insecurity among consumers in the Palestinian West Bank is developed and included as a variable to explore how perceptions of control, or lack thereof, impact consumption behavior and resulting estimates of price elasticity. A multivariate regression model demonstrates the significance of a water insecurity variable for data sets encompassing disparate water access. When accounting for insecurity, the R-squaed value improves and the marginal price a household is willing to pay becomes a significant predictor for the household quantity consumption. The model denotes that, with all other variables held equal, a household will buy more water when the users are more water insecure. Though the reasons behind this trend require further study, the findings suggest broad policy implications by demonstrating that water distribution practices in scarcity conditions can promote consumer welfare and efficient water use.

  20. Physicochemical Factors Influence the Abundance and Culturability of Human Enteric Pathogens and Fecal Indicator Organisms in Estuarine Water and Sediment

    Directory of Open Access Journals (Sweden)

    Francis Hassard

    2017-10-01

    Full Text Available To assess fecal pollution in coastal waters, current monitoring is reliant on culture-based enumeration of bacterial indicators, which does not account for the presence of viable but non-culturable or sediment-associated micro-organisms, preventing effective quantitative microbial risk assessment (QMRA. Seasonal variability in viable but non-culturable or sediment-associated bacteria challenge the use of fecal indicator organisms (FIOs for water monitoring. We evaluated seasonal changes in FIOs and human enteric pathogen abundance in water and sediments from the Ribble and Conwy estuaries in the UK. Sediments possessed greater bacterial abundance than the overlying water column, however, key pathogenic species (Shigella spp., Campylobacter jejuni, Salmonella spp., hepatitis A virus, hepatitis E virus and norovirus GI and GII were not detected in sediments. Salmonella was detected in low levels in the Conwy water in spring/summer and norovirus GII was detected in the Ribble water in winter. The abundance of E. coli and Enterococcus spp. quantified by culture-based methods, rarely matched the abundance of these species when measured by qPCR. The discrepancy between these methods was greatest in winter at both estuaries, due to low CFU's, coupled with higher gene copies (GC. Temperature accounted for 60% the variability in bacterial abundance in water in autumn, whilst in winter salinity explained 15% of the variance. Relationships between bacterial indicators/pathogens and physicochemical variables were inconsistent in sediments, no single indicator adequately described occurrence of all bacterial indicators/pathogens. However, important variables included grain size, porosity, clay content and concentrations of Zn, K, and Al. Sediments with greater organic matter content and lower porosity harbored a greater proportion of non-culturable bacteria (including dead cells and extracellular DNA in winter. Here, we show the link between physicochemical

  1. Concentration factors for Cs-137 in marine algae from Japanese coastal waters

    International Nuclear Information System (INIS)

    Tateda, Yutaka; Koyanagi, Taku.

    1994-01-01

    Concentration factors (CF: Bq·kg -1 in wet algae/Bq·kg -1 in filtered seawater) for Cs-137 in Japanese coastal algae, were investigated during 1984-1990. Cs-137/Cs (stable) atom ratios were also examined to clarify the distribution equilibrium of Cs-137 in marine algae and sea water. The CFs in marine algae were within the range of 5.4-92, and the geometric mean of CF was 28±2 (standard error) in Japanese coastal species. The CFs in edible species were within the range of 5.4-67, and the geometric means of CF was 26±4 (standard error). The values of Cs-137/Cs atom ratios in marine algae and sea water indicated that Cs-137 reached an equilibrium state in partition between algae and sea water. Therefore, the CF value obtained in the present study can be regarded as an equilibrated value. Our results showed that hte CF for Cs-137 in Japanese coastal algae were consistent with the Japanese guideline CFs, but were smaller than the recommended value by IAEA. (author)

  2. Children and adolescents' internal models of food-sharing behavior include complex evaluations of contextual factors.

    Science.gov (United States)

    Markovits, Henry; Benenson, Joyce F; Kramer, Donald L

    2003-01-01

    This study examined internal representations of food sharing in 589 children and adolescents (8-19 years of age). Questionnaires, depicting a variety of contexts in which one person was asked to share a resource with another, were used to examine participants' expectations of food-sharing behavior. Factors that were varied included the value of the resource, the relation between the two depicted actors, the quality of this relation, and gender. Results indicate that internal models of food-sharing behavior showed systematic patterns of variation, demonstrating that individuals have complex contextually based internal models at all ages, including the youngest. Examination of developmental changes in use of individual patterns is consistent with the idea that internal models reflect age-specific patterns of interactions while undergoing a process of progressive consolidation.

  3. Analysis on the spatiotemporal characteristics of water quality and trophic states in Tiegang Reservoir: A public drinking water supply reservoir in South China

    Science.gov (United States)

    Song, Yun-long; Zhu, Jia; Li, Wang; Tao, Yi; Zhang, Jin-song

    2017-08-01

    Shenzhen is the most densely populated city in China and with a severe shortage of water. The per capita water resource is less than 200 m3, which is approximately 1/12 of the national average level. In 2016, nearly 90% of Shenzhen’s drinking water needed to be imported from the Pearl River. After arrived at Shenzhen, overseas water was firstly stockpiled in local reservoirs and then was supplied to nearby water works. Tiegang Reservoir is the largest drinking water supply reservoir and its water quality has played an important role to the city’s drinking water security. A fifteen-month’s field observation was conducted from April 2013 to June 2014 in Tiegang Reservoir, in order to analyze the temporal and spatial distribution of water quality factors and seasonal variation of trophic states. One-way ANOVA showed that significant difference was found in water quality factors on month (p latter rainy period > high temperature and rain free period > temperature jump period > winter drought period, while SD showed the contrary. Two-way ANOVA showed that months rather than locations were the key influencing factors of water quality factors succession. Tiegang reservoir was seriously polluted by TN, as a result WQI were at IV∼V level. If TN was not taken into account, WQI were atI∼III level. TLI (Σ) were about 35∼60, suggesting Tiegang reservoir was in mesotrophic and light-eutrophic trophic states. The WQI and TLI (Σ) in sampling sites 9 and 10 were poorer than that of other sites. The 14 water quality factors were divided into 5 groups by factor analysis (FA). The total interpretation rate was 73.54%. F1 represents the climatic change represented by water temperature. F2 and F4 represent the concentration of nutrients. F3 and F5 represent the sensory indexes of water body, such as turbidity, transparency. The FA results indicated that water quality potential risk factors was total nitrogen (TN), and potential risk factors also include chlorophyll-a and

  4. An overview of reclaimed water reuse in China.

    Science.gov (United States)

    Yi, Lili; Jiao, Wentao; Chen, Xiaoning; Chen, Weiping

    2011-01-01

    China is facing severe water problems including scarcity and pollution which are now becoming key factors restricting developments. Creating an alternative water resource and reducing effluent discharges, water reuse has been recognized as an integral part of water and wastewater management scheme in China. The government has launched nationwide efforts to optimize the benefits of utilizing reclaimed water. This article reviewed the water reuse activities in China, including: (1) application history and current status; (2) potentials of reclaimed water reuse; (3) laws, policies and regulations governing reclaimed water reuse; (4) risks associated with reclaimed water reuse; (5) issues in reclaimed water reuse. Reclaimed water in Beijing and Tianjin were given as examples. Suggestions for improving the efficiencies of reusing urban wastewater were advanced. Being the largest user of reclaimed wastewater in the world, China's experience can benefit the development of water reuse in other regions.

  5. Analyzing the factors affecting optimal management of saline water by application of Sustainable Livelihoods Framework

    Directory of Open Access Journals (Sweden)

    Masoumeh Forouzani

    2016-11-01

    Full Text Available In recent years, fresh water has been increasingly reduced and saline water has been one of the options to help the continuity and stability of agricultural activities. Hence, long-term sustainability of saline water irrigation depends on how to manage it at the fields. Optimal management requires identifying the factors affecting it. In this regard, this study used the descriptive–survey method to analyze the factors affecting the optimal management of saline water based on the Sustainable Livelihoods Framework. The statistical population of the study consisted of all the farmers of the Karun County (N=19720. By using the table of Krejcie and Morgan, the sample size was determined (n= 120. The sample was chosen through the simple random sampling method. Data were collected using a questionnaire. The questionnaire's face and content validity were approved by a panel of the agricultural extension and education experts and its reliability was confirmed by calculating the Cranach’s alpha coefficient (0.65-0.83. The data was analyzed by using the SPSS software. At the first stage the variables was converted to standard scores in order to construct livelihood assets indices. Then, principal component analysis was ran to assign the weights of the indicators. The results showed that farmers' management behavior in using saline water was dominated by technical management manners. Social capital and physical capital were known as the most and least livelihood assets of farmers, respectively. Also, there were statistically significant differences in farmers' management behavior based on their livelihood assets.

  6. Exploration of factors influencing shimming and water suppression on hepatic 1H-MR spectroscopy in vivo on 3.0 T

    International Nuclear Information System (INIS)

    Liang Changhong; Xu Li; Liu Zaiyi; Cui Yanhai; Liu Chunling; Zheng Junhui; Zeng Qiongxin

    2009-01-01

    Objective: To characterize the clinical factors which influence water suppression and auto-shimming line width for liver 3.0 T 1 H-MRS. Methods: Fifty-seven cases with liver 1 H-MR spectroscopy ( 1 H-MRS) were retrospectively studied, including chronic type B hepatitis (n=5), fatty liver (n=14), chronic type B hepatitis combining fatty liver (n=3) and normal situation (n=35). Independent t test was used to characterize the difference of general condition (height, weight, body mass index etc.) between different water suppression effect groups and between different shimming effect groups. Using Chi-square test to analyze whether water suppression rate and auto-shimming line width between fatty liver groups and non-fatty liver exist significance difference. Results: By comparing WS ≥90% (n=47) group with WS 2 respectively] and LW [(17.7±3.7) and (24.6±6.3) Hz respectively] than the latter (t=-3.488, -3.415, -4.002 and -3.327, P 20 Hz (n=16) group, the former showed better water suppression rate [(93.0±2.7)% and (86.1±8.5)% respectively] than the latter (t=3.213, P 2 respectively] (t=-2.516, -2.024, P 2 =11.347, P 2 =28.536, P<0.05). Conclusion: Hepatic steatosis exerts an adverse effect in water suppression and shimming. (authors)

  7. STUDY ON THE FACTORS INFLUENCING HYDRATION AND WATER RETENTION CAPACITY OF MEAT

    OpenAIRE

    DANIELA IANIłCHI; CARMEN NICOLAE; CRISTIANA DIACONESCU; GABRIELA MALOS; I. G. MALOS

    2008-01-01

    Top-quality food produce and high profitability in processing requires high quality in raw materials. Therefore, to achieve these objectives, it is imperative to know the properties of the war materials, and the factors that influence these properties.The properties of the meat directly involved in increasing economic efficiency and final produce quality are the so-called technological properties: hydration capacity and water retention capacity of meat. These properties are determined by some...

  8. Factors controlling As and U in shallow ground water, southern Carson Desert, Nevada

    Science.gov (United States)

    Welch, A.H.; Lico, M.S.

    1998-01-01

    Unusually high As and U concentrations (> 100 ??g/L) are widespread in shallow ground water beneath the southern Carson Desert. The high concentrations, which locally exceed 1000 ??g/L, are of concern from a human health standpoint because the shallow ground water is used for domestic supply. Possible affects on wildlife are also of concern because the ground water flows into shallow lakes and marshes within wildlife refuges. Arsenic and U concentrations in ground water of the southern Carson Desert appear to be affected by evaporative concentration, redox reactions, and adsorption. The relation of these elements with Cl suggest that most of the high concentrations can be attributed to evaporative concentration of Carson River water, the primary source of recharge. Some ground water contains higher As and U concentrations that cannot be explained by evaporative concentration alone. Oxidation-reduction reactions, involving metal oxides and sedimentary-organic matter, appear to contribute As, U, inorganic C, Fe and Mn to the ground water. Arsenic in Fe-oxide was confirmed by chemical extraction and is consistent with laboratory adsorption studies. Uranium in both sedimentary-organic C and Fe-oxide coatings has been confirmed by fission tracks and petrographic examination. Arsenic concentrations in the ground water and chemical extracts of aquifer sediments are broadly consistent with adsorption as a control on some dissolved As concentrations. An apparent loss of As from some ground water as evaporative concentration proceeds is consistent with adsorption as a control on As. However, evidence for adsorption should be viewed with caution, because the adsorption model used values for the adsorbent that have not been shown to be valid for the aquifer sediments throughout the southern Carson Desert. Hydrologic and geochemical conditions in the Carson Desert are similar to other areas with high As and U concentrations in ground water, including the Salton Sea basin and

  9. Factors controlling As and U in shallow ground water, southern Carson Desert, Nevada

    International Nuclear Information System (INIS)

    Lico, M.S.; Welch, A.H.

    1998-01-01

    100 μg/L) are widespread in shallow ground water beneath the southern Carson Desert. The high concentrations, which locally exceed 1000 μg/L, are of concern from a human health standpoint because the shallow ground water is used for domestic supply. Possible affects on wildlife are also of concern because the ground water flows into shallow lakes and marshes within wildlife refuges. Arsenic and U concentrations in ground water of the southern Carson Desert appear to be affected by evaporative concentration, redox reactions, and adsorption. The relation of these elements with Cl suggest that most of the high concentrations can be attributed to evaporative concentration of Carson River water, the primary source of recharge.Some ground water contains higher As and U concentrations that cannot be explained by evaporative concentration alone. Oxidation-reduction reactions, involving metal oxides and sedimentary-organic matter, appear to contribute As, U, inorganic C, Fe and Mn to the ground water. Arsenic in Fe-oxide was confirmed by chemical extraction and is consistent with laboratory adsorption studies. Uranium in both sedimentary-organic C and Fe-oxide coatings has been confirmed by fission tracks and petrographic examination.Arsenic concentrations in the ground water and chemical extracts of aquifer sediments are broadly consistent with adsorption as a control on some dissolved As concentrations. An apparent loss of As from some ground water as evaporative concentration proceeds is consistent with adsorption as a control on As. However, evidence for adsorption should be viewed with caution, because the adsorption model used values for the adsorbent that have not been shown to be valid for the aquifer sediments throughout the southern Carson Desert.Hydrologic and geochemical conditions in the Carson Desert are similar to other areas with high As and U concentrations in ground water, including the Salton Sea basin and southern San Joaquin Valley of California

  10. Uptake of Mn and Cd by Wild Water Spinach and Their Bioaccumulation and Translocation Factors

    Directory of Open Access Journals (Sweden)

    Billy Teck Huat Guan

    2017-01-01

    Full Text Available Polluted ponds and lakes close to agricultural activities become the exposure route of manganese (Mn and cadmium (Cd to aquatic plants in near vicinity. Therefore, a study of the uptake, bioaccumulation, and translocation of Mn and Cd by the water spinach (Ipomoea aquatica is presented in this paper. Different concentrations of Mn and Cd were added to the hydroponic nutrient solution that was used to grow the plants for the heavy metal uptake experiment under greenhouse conditions. The plant samples exposed to heavy metals were collected to determine the metal concentrations using atomic absorption spectroscopy (AAS and the metal concentrations were found for Mn was between 1.589 to 9.696 µg/g and Cd from 5.309 to 10.947 µg/g. The correlation and regression results showed that the water-to-shoot bioaccumulation factor (BAF decreased for Mn, while root-to-shoot translocation factor (TF values increased in the order Cd > Mn to the increasing levels of metals in the water. Furthermore, it was revealed from the two-way analysis of variance (ANOVA that the different metal types influenced the BAF and TF values at different metal concentration treatments.

  11. Shallow water table effects on water, sediment, and pesticide transport in vegetative filter strips – Part 2: model coupling, application, factor importance, and uncertainty

    Directory of Open Access Journals (Sweden)

    C. Lauvernet

    2018-01-01

    Full Text Available Vegetative filter strips are often used for protecting surface waters from pollution transferred by surface runoff in agricultural watersheds. In Europe, they are often prescribed along the stream banks, where a seasonal shallow water table (WT could decrease the buffer zone efficiency. In spite of this potentially important effect, there are no systematic experimental or theoretical studies on the effect of this soil boundary condition on the VFS efficiency. In the companion paper (Muñoz-Carpena et al., 2018, we developed a physically based numerical algorithm (SWINGO that allows the representation of soil infiltration with a shallow water table. Here we present the dynamic coupling of SWINGO with VFSMOD, an overland flow and transport mathematical model to study the WT influence on VFS efficiency in terms of reductions of overland flow, sediment, and pesticide transport. This new version of VFSMOD was applied to two contrasted benchmark field studies in France (sandy-loam soil in a Mediterranean semicontinental climate, and silty clay in a temperate oceanic climate, where limited testing of the model with field data on one of the sites showed promising results. The application showed that for the conditions of the studies, VFS efficiency decreases markedly when the water table is 0 to 1.5 m from the surface. In order to evaluate the relative importance of WT among other input factors controlling VFS efficiency, global sensitivity and uncertainty analysis (GSA was applied on the benchmark studies. The most important factors found for VFS overland flow reduction were saturated hydraulic conductivity and WT depth, added to sediment characteristics and VFS dimensions for sediment and pesticide reductions. The relative importance of WT varied as a function of soil type (most important at the silty-clay soil and hydraulic loading (rainfall + incoming runoff at each site. The presence of WT introduced more complex responses dominated by strong

  12. Development of characterization factors for metals in 7 EU water archetypes

    DEFF Research Database (Denmark)

    Dong, Yan; Hauschild, Michael Zwicky

    of the metals, WHAM 7.0 is used to model the metal speciation, Kd values and bioavailability, while the Free Ion Activity Model (FIAM) is used to model the ecotoxicity effect. The resulting archetype-specific CFs show up to ~4 orders of magnitude difference for Cr and Be. This indicates that the toxicity...... in the frequent situation where no information is available of the specific water type into which the metal emission occurs, site generic average factors are also calculated and different approaches to averaging across archetypes are investigated and discussed....

  13. Probing the structural and dynamical properties of liquid water with models including non-local electron correlation

    International Nuclear Information System (INIS)

    Del Ben, Mauro; Hutter, Jürg; VandeVondele, Joost

    2015-01-01

    Water is a ubiquitous liquid that displays a wide range of anomalous properties and has a delicate structure that challenges experiment and simulation alike. The various intermolecular interactions that play an important role, such as repulsion, polarization, hydrogen bonding, and van der Waals interactions, are often difficult to reproduce faithfully in atomistic models. Here, electronic structure theories including all these interactions at equal footing, which requires the inclusion of non-local electron correlation, are used to describe structure and dynamics of bulk liquid water. Isobaric-isothermal (NpT) ensemble simulations based on the Random Phase Approximation (RPA) yield excellent density (0.994 g/ml) and fair radial distribution functions, while various other density functional approximations produce scattered results (0.8-1.2 g/ml). Molecular dynamics simulation in the microcanonical (NVE) ensemble based on Møller-Plesset perturbation theory (MP2) yields dynamical properties in the condensed phase, namely, the infrared spectrum and diffusion constant. At the MP2 and RPA levels of theory, ice is correctly predicted to float on water, resolving one of the anomalies as resulting from a delicate balance between van der Waals and hydrogen bonding interactions. For several properties, obtaining quantitative agreement with experiment requires correction for nuclear quantum effects (NQEs), highlighting their importance, for structure, dynamics, and electronic properties. A computed NQE shift of 0.6 eV for the band gap and absorption spectrum illustrates the latter. Giving access to both structure and dynamics of condensed phase systems, non-local electron correlation will increasingly be used to study systems where weak interactions are of paramount importance

  14. Fever in trauma patients: evaluation of risk factors, including traumatic brain injury.

    Science.gov (United States)

    Bengualid, Victoria; Talari, Goutham; Rubin, David; Albaeni, Aiham; Ciubotaru, Ronald L; Berger, Judith

    2015-03-01

    The role of fever in trauma patients remains unclear. Fever occurs as a response to release of cytokines and prostaglandins by white blood cells. Many factors, including trauma, can trigger release of these factors. To determine whether (1) fever in the first 48 hours is related to a favorable outcome in trauma patients and (2) fever is more common in patients with head trauma. Retrospective study of trauma patients admitted to the intensive care unit for at least 2 days. Data were analyzed by using multivariate analysis. Of 162 patients studied, 40% had fever during the first 48 hours. Febrile patients had higher mortality rates than did afebrile patients. When adjusted for severity of injuries, fever did not correlate with mortality. Neither the incidence of fever in the first 48 hours after admission to the intensive care unit nor the number of days febrile in the unit differed between patients with and patients without head trauma (traumatic brain injury). About 70% of febrile patients did not have a source found for their fever. Febrile patients without an identified source of infection had lower peak white blood cell counts, lower maximum body temperature, and higher minimum platelet counts than did febrile patients who had an infectious source identified. The most common infection was pneumonia. No relationship was found between the presence of fever during the first 48 hours and mortality. Patients with traumatic brain injury did not have a higher incidence of fever than did patients without traumatic brain injury. About 30% of febrile patients had an identifiable source of infection. Further studies are needed to understand the origin and role of fever in trauma patients. ©2015 American Association of Critical-Care Nurses.

  15. Environmental factors shaping cultured free-living amoebae and their associated bacterial community within drinking water network.

    Science.gov (United States)

    Delafont, Vincent; Bouchon, Didier; Héchard, Yann; Moulin, Laurent

    2016-09-01

    Free-living amoebae (FLA) constitute an important part of eukaryotic populations colonising drinking water networks. However, little is known about the factors influencing their ecology in such environments. Because of their status as reservoir of potentially pathogenic bacteria, understanding environmental factors impacting FLA populations and their associated bacterial community is crucial. Through sampling of a large drinking water network, the diversity of cultivable FLA and their bacterial community were investigated by an amplicon sequencing approach, and their correlation with physicochemical parameters was studied. While FLA ubiquitously colonised the water network all year long, significant changes in population composition were observed. These changes were partially explained by several environmental parameters, namely water origin, temperature, pH and chlorine concentration. The characterisation of FLA associated bacterial community reflected a diverse but rather stable consortium composed of nearly 1400 OTUs. The definition of a core community highlighted the predominance of only few genera, majorly dominated by Pseudomonas and Stenotrophomonas. Co-occurrence analysis also showed significant patterns of FLA-bacteria association, and allowed uncovering potentially new FLA - bacteria interactions. From our knowledge, this study is the first that combines a large sampling scheme with high-throughput identification of FLA together with associated bacteria, along with their influencing environmental parameters. Our results demonstrate the importance of physicochemical parameters in the ecology of FLA and their bacterial community in water networks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Including impacts of particulate emissions on marine ecosystems in life cycle assessment: the case of offshore oil and gas production.

    Science.gov (United States)

    Veltman, Karin; Huijbregts, Mark A J; Rye, Henrik; Hertwich, Edgar G

    2011-10-01

    Life cycle assessment is increasingly used to assess the environmental performance of fossil energy systems. Two of the dominant emissions of offshore oil and gas production to the marine environment are the discharge of produced water and drilling waste. Although environmental impacts of produced water are predominantly due to chemical stressors, a major concern regarding drilling waste discharge is the potential physical impact due to particles. At present, impact indicators for particulate emissions are not yet available in life cycle assessment. Here, we develop characterization factors for 2 distinct impacts of particulate emissions: an increased turbidity zone in the water column and physical burial of benthic communities. The characterization factor for turbidity is developed analogous to characterization factors for toxic impacts, and ranges from 1.4 PAF (potentially affected fraction) · m(3) /d/kg(p) (kilogram particulate) to 7.0 x 10³ [corrected] for drilling mud particles discharged from the rig. The characterization factor for burial describes the volume of sediment that is impacted by particle deposition on the seafloor and equals 2.0 × 10(-1) PAF · m(3) /d/kg(p) for cutting particles. This characterization factor is quantified on the basis of initial deposition layer characteristics, such as height and surface area, the initial benthic response, and the recovery rate. We assessed the relevance of including particulate emissions in an impact assessment of offshore oil and gas production. Accordingly, the total impact on the water column and on the sediment was quantified based on emission data of produced water and drilling waste for all oil and gas fields on the Norwegian continental shelf in 2008. Our results show that cutting particles contribute substantially to the total impact of offshore oil and gas production on marine sediments, with a relative contribution of 55% and 31% on the regional and global scale, respectively. In contrast, the

  17. Distilled Water Distribution Systems. Laboratory Design Notes.

    Science.gov (United States)

    Sell, J.C.

    Factors concerning water distribution systems, including an evaluation of materials and a recommendation of materials best suited for service in typical facilities are discussed. Several installations are discussed in an effort to bring out typical features in selected applications. The following system types are included--(1) industrial…

  18. China’s Water Utilization Efficiency: An Analysis with Environmental Considerations

    Directory of Open Access Journals (Sweden)

    Hailiang Ma

    2016-05-01

    Full Text Available This paper estimates China’s water utilization efficiency using the directional distance function to take into account the environmental degradation affecting the economy. We further analyze the spatial correlation and the factors influencing the utilization efficiency using spatial panel data models. The results show that water utilization efficiency in China differs between provinces and regions. For example, water utilization efficiency in the eastern coastal provinces is significantly higher than that of inland provinces. The pattern of spatial auto-correlation Moran’s I index presents significant spatial auto-correlation and evident cluster tendencies in China’s inter-provincial water utilization. Factors that contribute to water utilization efficiency include economic development, technological progress, and economic openness. Negative factors affecting water utilization efficiency arise from industrial structure, government interference, and water resources endowment. In addition, the price of water resources is insignificant. The improvement of water utilization efficiency is essential to sustainable economic development. To raise the utilization efficiency of water resources, China should focus on transforming its industrial restructure, advancing technological development, enhancing economic openness, and encouraging entrepreneurial innovations. Moreover, establishing a mechanism to encourage water conservation and reduce wastewater pollution will further increase water utilization efficiency.

  19. Improved USLE-K factor prediction: A case study on water erosion areas in China

    Directory of Open Access Journals (Sweden)

    Bin Wang

    2016-09-01

    Full Text Available Soil erodibility (K-factor is an essential factor in soil erosion prediction and conservation practises. The major obstacles to any accurate, large-scale soil erodibility estimation are the lack of necessary data on soil characteristics and the misuse of variable K-factor calculators. In this study, we assessed the performance of available erodibility estimators Universal Soil Loss Equation (USLE, Revised Universal Soil Loss Equation (RUSLE, Erosion Productivity Impact Calculator (EPIC and the Geometric Mean Diameter based (Dg model for different geographic regions based on the Chinese soil erodibility database (CSED. Results showed that previous estimators overestimated almost all K-values. Furthermore, only the USLE and Dg approaches could be directly and reliably applicable to black and loess soil regions. Based on the nonlinear best fitting techniques, we improved soil erodibility prediction by combining Dg and soil organic matter (SOM. The NSE, R2 and RE values were 0.94, 0.67 and 9.5% after calibrating the results independently; similar model performance was showed for the validation process. The results obtained via the proposed approach were more accurate that the former K-value predictions. Moreover, those improvements allowed us to effectively establish a regional soil erodibility map (1:250,000 scale of water erosion areas in China. The mean K-value of Chinese water erosion regions was 0.0321 (t ha h·(ha MJ mm−1 with a standard deviation of 0.0107 (t ha h·(ha MJ mm−1; K-values present a decreasing trend from North to South in water erosion areas in China. The yield soil erodibility dataset also satisfactorily corresponded to former K-values from different scales (local, regional, and national.

  20. 137Cs absorption factors (AFs) from contaminated cooking water to some vegetable and protein samples

    International Nuclear Information System (INIS)

    Malek, M.A.

    2006-01-01

    The radionuclide in contaminated freshwater may directly gain access to the human body through two major routes: drinking and cooking food with fresh water. During cooking, the radionuclide present in the water may be transferred to the various ingredients of the cooked food. The degree of contamination of food during cooking depends both on absorption power of the individual ingredients and the level of radionuclide present in the water. The ratio of the concentration of the radionuclide absorbed in the individual ingredients to the concentration in the cooking water can be designated as 'Absorption factor' (AF). AF can be used to predict the radionuclide absorbed by the ingredients cooked with contaminated water, to assess the internal radiation dose to the consumer and radionuclide transfer from the cooking water to the ingredients. A better understanding of the variables that affect the AF in various ingredients during cooking is central to deriving the contamination level of the ingredients. 10 kinds of greens and vegetable and 3 kinds of animal protein were boiled with 37 Cs contaminated freshwater and corresponding AFs were determined in both hot and cooled condition

  1. Impacts of Water Quality on Residential Water Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Baechler, Michael C.

    2013-11-01

    Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

  2. Impact of individual and worksite environmental factors on water and sugar-sweetened beverage consumption among overweight employees.

    Science.gov (United States)

    Davy, Brenda M; You, Wen; Almeida, Fabio; Wall, Sarah; Harden, Samantha; Comber, Dana L; Estabrooks, Paul A

    2014-05-01

    The worksite environment may influence employees' dietary behaviors. Consumption of water and sugar-sweetened beverages (SSBs) affect weight management; however, little research has evaluated the influence of worksite factors on beverage consumption. Our purpose was to determine whether individual and worksite factors are associated with water and SSB intake among overweight and obese employees. Data were collected as part of baseline assessments for a worksite-based, weight-management intervention trial. Height and weight of participants (N = 1,482; 74% female; mean age = 47 y [standard deviation (SD) = 11 y]; mean weight = 208 lbs [SD = 46 lbs]) were assessed, and participants completed a validated beverage intake questionnaire. Environmental characteristics of worksites (N = 28) were audited. A qualitative comparative analysis (QCA) was used to identify worksite conditions that may support healthier beverage intake patterns. Most participants were white (75% of sample) with at least some college education or a college degree (approximately 82% of sample). Mean water and SSB intake were 27 fl oz (SD = 18 fl oz) and 17 fl oz (SD = 18 fl oz), respectively; SSB intake (191 kcal [SD = 218 kcal]) exceeded the recommended discretionary energy intake. Statistical models did not identify any significant predictors of water intake. Female sex and increasing level of education and household income were associated with lower SSB intake; baseline body weight and greater number of worksite water coolers and vending machines were associated with higher SSB intake. The QCA identified worksite type (ie, not manual labor) as a condition necessary for healthier beverage consumption; a worksite break policy of 2 or more per day may lead to unhealthy beverage consumption. Lower SSB consumption was noted among older participants, female participants, and among participants with higher education and income levels. Workplace factors influence beverage consumption among overweight

  3. Water-driven micromotors.

    Science.gov (United States)

    Gao, Wei; Pei, Allen; Wang, Joseph

    2012-09-25

    We demonstrate the first example of a water-driven bubble-propelled micromotor that eliminates the requirement for the common hydrogen peroxide fuel. The new water-driven Janus micromotor is composed of a partially coated Al-Ga binary alloy microsphere prepared via microcontact mixing of aluminum microparticles and liquid gallium. The ejection of hydrogen bubbles from the exposed Al-Ga alloy hemisphere side, upon its contact with water, provides a powerful directional propulsion thrust. Such spontaneous generation of hydrogen bubbles reflects the rapid reaction between the aluminum alloy and water. The resulting water-driven spherical motors can move at remarkable speeds of 3 mm s(-1) (i.e., 150 body length s(-1)), while exerting large forces exceeding 500 pN. Factors influencing the efficiency of the aluminum-water reaction and the resulting propulsion behavior and motor lifetime, including the ionic strength and environmental pH, are investigated. The resulting water-propelled Al-Ga/Ti motors move efficiently in different biological media (e.g., human serum) and hold considerable promise for diverse biomedical or industrial applications.

  4. Hydraulic Model for Drinking Water Networks, Including Household Connections; Modelo hidraulico para redes de agua potable con tomas domiciliarias

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero Angulo, Jose Oscar [Universidad Autonoma de Sinaloa (Mexico); Arreguin Cortes, Felipe [Instituto Mexicano de Tecnologia del Agua, Jiutepec, Morelos (Mexico)

    2002-03-01

    This paper presents a hydraulic simulation model for drinking water networks, including elements that are currently not considered household connections, spatially variable flowrate distribution pipelines, and tee secondary network. This model is determined by solving the equations needed for a conventional model following an indirect procedure for the solution of large equations systems. Household connection performance is considered as dependent of water pressure and the way in which users operate the taps of such intakes. This approach allows a better a acquaintance with the drinking water supply networks performance as well as solving problems that demand a more precise hydraulic simulation, such as water quality variations, leaks in networks, and the influence of home water tanks as regulating devices. [Spanish] Se presenta un modelo de simulacion hidraulica para redes de agua potable en el cual se incluyen elementos que no se toman en cuenta actualmente, como las tomas domiciliarias, los tubos de distribucion con gastos espacialmente variado y la red secundaria, resolviendo el numero de ecuaciones que seria necesario plantear en un modelo convencional mediante un procedimiento indirecto para la solucion de grandes sistemas de ecuaciones. En las tomas domiciliarias se considera que su funcionamiento depende de las presiones y la forma en que los usuarios operan las llaves de las mismas. Este planteamiento permite conocer mejor el funcionamiento de las redes de abastecimiento de agua potable y solucionar problemas que requieren de una simulacion hidraulica mas precisa, como el comportamiento de la calidad del agua, las fugas en las redes y la influencia reguladora de los tinacos de las casas.

  5. Identification of key factors affecting the water pollutant concentration in the sluice-controlled river reaches of the Shaying River in China via statistical analysis methods.

    Science.gov (United States)

    Dou, Ming; Zhang, Yan; Zuo, Qiting; Mi, Qingbin

    2015-08-01

    The construction of sluices creates a strong disturbance in water environmental factors within a river. The change in water pollutant concentrations of sluice-controlled river reaches (SCRRs) is more complex than that of natural river segments. To determine the key factors affecting water pollutant concentration changes in SCRRs, river reaches near the Huaidian Sluice in the Shaying River of China were selected as a case study, and water quality monitoring experiments based on different regulating modes were implemented in 2009 and 2010. To identify the key factors affecting the change rates for the chemical oxygen demand of permanganate (CODMn) and ammonia nitrogen (NH3-N) concentrations in the SCRRs of the Huaidian Sluice, partial correlation analysis, principal component analysis and principal factor analysis were used. The results indicate four factors, i.e., the inflow quantity from upper reaches, opening size of sluice gates, water pollutant concentration from upper reaches, and turbidity before the sluice, which are the common key factors for the CODMn and NH3-N concentration change rates. Moreover, the dissolved oxygen before a sluice is a key factor for the permanganate concentration from CODMn change rate, and the water depth before a sluice is a key factor for the NH3-N concentration change rate. Multiple linear regressions between the water pollutant concentration change rate and key factors were established via multiple linear regression analyses, and the quantitative relationship between the CODMn and NH3-N concentration change rates and key affecting factors was analyzed. Finally, the mechanism of action for the key factors affecting the water pollutant concentration changes was analyzed. The results reveal that the inflow quantity from upper reaches, opening size of sluice gates, permanganate concentration from CODMn from upper reaches and dissolved oxygen before the sluice have a negative influence and the turbidity before the sluice has a positive

  6. Prognostic factors for head and neck cancer of unknown primary including the impact of human papilloma virus infection.

    Science.gov (United States)

    Axelsson, Lars; Nyman, Jan; Haugen-Cange, Hedda; Bove, Mogens; Johansson, Leif; De Lara, Shahin; Kovács, Anikó; Hammerlid, Eva

    2017-06-10

    Head and neck cancer of unknown primary (HNCUP) is rare and prospective studies are lacking. The impact of different prognostic factors such as age and N stage is not completely known, the optimal treatment is not yet established, and the reported survival rates vary. In the last decade, human papilloma virus (HPV) has been identified as a common cause of and important prognostic factor in oropharyngeal cancer, and there is now growing interest in the importance of HPV for HNCUP. The aim of the present study on curatively treated HNCUP was to investigate the prognostic importance of different factors, including HPV status, treatment, and overall survival. A search for HNCUP was performed in the Swedish Cancer Registry, Western health district, between the years 1992-2009. The medical records were reviewed, and only patients with squamous cell carcinoma or undifferentiated carcinoma treated with curative intent were included. The tumor specimens were retrospectively analyzed for HPV with p16 immunostaining. Sixty-eight patients were included. The mean age was 59 years. The majority were males, and had N2 tumors. Sixty-nine percent of the tumors were HPV positive using p16 staining. Patients who were older than 70 years, patients with N3-stage tumors, and patients with tumors that were p16 negative had a significantly worse prognosis. The overall 5-year survival rate for patients with p16-positive tumors was 88% vs 61% for p16-negative tumors. Treatment with neck dissection and postoperative radiation or (chemo) radiation had 81 and 88% 5-year survival rates, respectively. The overall and disease-free 5-year survival rates for all patients in the study were 82 and 74%. Curatively treated HNCUP had good survival. HPV infection was common. Independent prognostic factors for survival were age over 70 years, HPV status and N3 stage. We recommend that HPV analysis should be performed routinely for HNCUP. Treatment with neck dissection and postoperative radiation or

  7. Experience with remediating radiostrontium-contaminated ground water and surface water with versions of AECL's CHEMIC process

    International Nuclear Information System (INIS)

    Vijayan, S.

    2006-01-01

    Numerous approaches have been developed for the remediation of radiostrontium ( 90 Sr) contaminated ground water and surface water. Several strontium-removal technologies have been assessed and applied at AECL's (Atomic Energy of Canada Limited) Chalk River Laboratories. These include simple ion exchange (based on non-selective natural zeolites or selective synthetic inorganic media), and precipitation and filtration with or without ion exchange as a final polishing step. AECL's CHEMIC process is based on precipitation-microfiltration and ion-exchange steps. This paper presents data related to radiostrontium removal performance and other operational experiences including troubleshooting with two round-the-clock, pilot-scale water remediation plants based on AECL's CHEMIC process at the Chalk River Laboratories site. These plants began operation in the early 1990s. Through optimization of process chemistry and operation, high values for system capability and system availability factors, and low concentrations of 90 Sr in the discharge water approaching drinking water standard can be achieved. (author)

  8. SUSTAINABLE ENVIRONMENTAL TECHNOLOGIES INCLUDING WATER RECOVERY FOR REUSE FROM TANNERY AND INDUSTRIAL WASTEWATER – INDIAN AND ASIAN SCENARIO

    Directory of Open Access Journals (Sweden)

    Dr. S. RAJAMANI

    2017-05-01

    Full Text Available World leather sector generates 600million m3 of wastewater per annum. The Asian tanneries contributes more than 350 million m3 of wastewater from the process of 8 to 10 millions tons of hides and skins. Environmental challenges due to depletion of quality water resources and increase in salinity, it has become necessary to control Total Dissolved Solids (TDS in the treated effluent with water recovery wherever feasible. Adoption of special membrane system has been engineered in many individual and Common Effluent Treatment Plants (CETPs in India, China and other leather producing countries. The sustainability of saline reject management is one of the major challenges. Conventional tannery wastewater treatment systems include physiochemical and biological treatment to reduce Chromium, BOD, COD and Suspended Solids. To tackle treated effluent with TDS in the rage of 10000 to 30000mg/l, multiple stage high pressure membrane units have been designed and implemented for recovery of water. To reduce the chemical usage and sludge generation in the tertiary treatment, Membrane Bio-Reactor (MBR has been adopted which replace secondary clarifier and sophisticated tertiary treatment units such as Reactive Clarifier, Ultra-filtration (UF, etc. Commercial scale high-tech membrane systems have been implemented in many locations for the capacities ranging from 500 to 10000m3/day. Recent applied R&D on the environmental protection techniques with focus on water-recovery for reuse, salt recovery, marine disposal of saline reject with proper bio-control system, etc. are dealt in this novel technical paper.

  9. Phosphorus and nitrogen in the eutrophication of waters

    International Nuclear Information System (INIS)

    Salonen, S.; Frisk, T.; Kaermeniemi, T.; Niemi, J.; Pitkaenen, H.; Silvo, K.; Vuoristo, H.

    1992-01-01

    This report is a summary of the contribution of nitrogen and phosphorus in the eutrophication process of inland and coastal waters. Special attention was paid to the mechanisms of these nutrients in regulating biological processes and to the methods available in estimating their effects in the eutrophication of water bodies. The report includes five chapters which are entitled: Introduction, which is a general background to the subject with special attention to the requirements of the Finnish Water Act. Phosphorus and nitrogen as factors regulating biological processes. The topics included are: definition of eutrophication, forms of phosphorus and nitrogen and their sources to inland and coastal waters, effects of these nutrients as growth factors of phytoplankton and macrophytes and consequences of eutrophication. Estimation of the effects of phosphorus and nitrogen. The topics discussed from the point of view of the tasks of the National Board of Waters and the Environment are: estimation of the effects of phosphorus and nitrogen in the planning and supervision of industry, fish farming, peat production, municipalities, agriculture and forestry. A brief state-of-the art of the research carried out in the National Board of Waters and the Environment is given. Methods of estimating the effects of phosphorus and nitrogen loading in waters. The topics are: relationships between phosphorus and nitrogen concentrations in waters, material balances, water quality models, classification of waters and different groups of organisms as indicators of water quality. Conclusions for the estimation of the effects of phosphorus and nitrogen in receiving waters

  10. Understanding Transitions Toward Sustainable Urban Water Management: Miami, Las Vegas, Los Angeles

    Science.gov (United States)

    Garcia, M. E.; Manago, K. F.; Treuer, G.; Deslatte, A.; Koebele, E.; Ernst, K.

    2016-12-01

    Cities in the United States face numerous threats to their long-term water supplies including preserving ecosystems, competing uses, and climate change. Yet, it is unclear why only some cities have transitioned toward more sustainable water management. These transitions include strategies such as water conservation, water supply portfolio diversification, long-term planning, and integrated resource management. While the circumstances that motivate or moderate transition may vary greatly across cities' physical and institutional contexts, identifying common factors associated with transition can help resource managers capitalize on windows of opportunity for change. To begin the process of identifying such factors, we ask two questions: 1) what combinations of conditions are associated with water management transitions?, and 2) what are the outcomes of these transitions? We examine three cases of utility-level water management in Miami, Las Vegas, and Los Angeles to create data-driven narratives detailing each city's transition. These narratives systematically synthesize multiple data sources to enable cross-case comparison and provide insights into how and why cities transition. Using the foundational concepts from the exposure-based theory of urban change, we focus our analysis on three broad categories of variables that influence urban water management transition: biophysical, political, and regulatory exposures. First, we compare these factors across time and across cities using metrics that standardize diverse data sources. Next, we incorporate qualitative factors that capture a city's unique conditions by integrating these metrics with salient contextual information. Then, through cross-city comparison, we identify factors associated with transition.

  11. An Assessment of Factors Having Impact on Water Quality in Water Supply Pipelines

    Directory of Open Access Journals (Sweden)

    Auksė Amosenkienė

    2011-04-01

    Full Text Available Water samples were collected from Vilnius drinking water distribution system fed by treated and different groundwater. Parameters related to bacterial growth have been measured considering these samples: temperature, concentration of free residual chlorine, ammonium, nitrates and nitrites. Results showed that treated groundwater was less susceptible to favour bacterial growth in the pipelines. The obtained results also showed that the potential growth induced by the distribution of treated water could be reduced if: ammonium levels were below 0.5 mg/l at the outlet of the water treatment plant; biological ammonium removal treatment implementation should reduce the levels of the nitrates and nitrites of the treated supplied water. Article in Lithuanian

  12. Factors affecting long-term trends in surface-water quality in the Gwynns Falls watershed, Baltimore City and County, Maryland, 1998–2016

    Science.gov (United States)

    Majcher, Emily H.; Woytowitz, Ellen L.; Reisinger, Alexander J.; Groffman, Peter M.

    2018-03-30

    Factors affecting water-quality trends in urban streams are not well understood, despite current regulatory requirements and considerable ongoing investments in gray and green infrastructure. To address this gap, long-term water-quality trends and factors affecting these trends were examined in the Gwynns Falls, Maryland, watershed during 1998–2016 in cooperation with Blue Water Baltimore. Data on water-quality constituents and potential factors of influence were obtained from multiple sources and compiled for analysis, with a focus on data collected as part of the National Science Foundation funded Long-Term Ecological Research project, the Baltimore Ecosystem Study.Variability in climate (specifically, precipitation) and land cover can overwhelm actions taken to improve water quality and can present challenges for meeting regulatory goals. Analysis of land cover during 2001–11 in the Gwynns Falls watershed indicated minimal change during the study time frame; therefore, land-cover change is likely not a factor affecting trends in water quality. However, a modest increase in annual precipitation and a significant increase in winter precipitation were apparent in the region. A higher proportion of runoff producing storms was observed in the winter and a lower proportion in the summer, indicating that climate change may affect water quality in the watershed. The increase in precipitation was not reflected in annual or seasonal trends of streamflow in the watershed. Nonetheless, these precipitation changes may exacerbate the inflow and infiltration of water to gray infrastructure and reduce the effectiveness of green infrastructure. For streamflow and most water-quality constituents examined, no discernable trends were noted over the timeframe examined. Despite the increases in precipitation, no trends were observed for annual or seasonal discharge at the various sites within the study area. In some locations, nitrate, phosphate, and total nitrogen show downward

  13. Importance of including small-scale tile drain discharge in the calibration of a coupled groundwater-surface water catchment model

    DEFF Research Database (Denmark)

    Hansen, Anne Lausten; Refsgaard, Jens Christian; Christensen, Britt Stenhøj Baun

    2013-01-01

    the catchment. In this study, a coupled groundwater-surface water model based on the MIKE SHE code was developed for the 4.7 km2 Lillebæk catchment in Denmark, where tile drain flow is a major contributor to the stream discharge. The catchment model was calibrated in several steps by incrementally including...... the observation data into the calibration to see the effect on model performance of including diverse data types, especially tile drain discharge. For the Lillebæk catchment, measurements of hydraulic head, daily stream discharge, and daily tile drain discharge from five small (1–4 ha) drainage areas exist....... The results showed that including tile drain data in the calibration of the catchment model improved its general performance for hydraulic heads and stream discharges. However, the model failed to correctly describe the local-scale dynamics of the tile drain discharges, and, furthermore, including the drain...

  14. Transfer factor for 137Cs in fresh water aquatic environment

    International Nuclear Information System (INIS)

    Varughese, K.G.; Ramkumar, S.; John, Jaison T.; Rajan, M.P.; Gurg, R.P.

    2002-01-01

    137 Cs is one of the most abundant radionuclides produced in nuclear fission and due to its long radiological half-life and chemical similarity to potassium it has greater biological significance. Radioactive waste materials generated at nuclear facilities are generally disposed within the plant premises under its administrative control for effective radiation protection practices. However trace quantities of radionuclides are released into the environment through liquid and gaseous releases under the guidelines of regulatory agencies. The concentration of these radioactive elements in the environment is not detectable under normal circumstances due to the large dispersion and dilutions available in the environment. But these radionuclides can get accumulated in environmental matrices like silt, weed etc. and indicate the presence of radioactivity in the environment. This paper presents the results of a face-controlled studies conducted at Environmental Survey Laboratories at the Rajasthan Atomic Power Station (RAPS) and Kakrapar Atomic Power Station (KAPS) to estimate distribution of low-level radioactivity in the fresh water system. An attempt has been made to derive the Transfer Factor for 137 Cs in fish, weed, and silt and to evaluate the concentration of 137 Cs in water samples, which is otherwise not detectable under normal procedure of measurement. (author)

  15. Identifying the principal driving factors of water ecosystem dependence and the corresponding indicator species in a pilot City, China

    Science.gov (United States)

    Zhao, C. S.; Shao, N. F.; Yang, S. T.; Xiang, H.; Lou, H. Z.; Sun, Y.; Yang, Z. Y.; Zhang, Y.; Yu, X. Y.; Zhang, C. B.; Yu, Q.

    2018-01-01

    The world's aquatic ecosystems yield numerous vital services, which are essential to human existence but have deteriorated seriously in recent years. By studying the mechanisms of interaction between ecosystems and habitat processes, the constraining factors can be identified, and this knowledge can be used to improve the success rate of ecological restoration initiatives. At present, there is insufficient data on the link between hydrological, water quality factors and the changes in the structure of aquatic communities to allow any meaningful study of driving factors of aquatic ecosystems. In this study, the typical monitoring stations were selected by fuzzy clustering analysis based on the spatial and temporal distribution characteristics of water ecology in Jinan City, the first pilot city for the construction of civilized aquatic ecosystems in China. The dominant species identification model was used to identify the dominant species of the aquatic community. The driving effect of hydrological and water quality factors on dominant species was analyzed by Canonical Correspondence Analysis. Then, the principal factors of aquatic ecosystem dependence were selected. The results showed that there were 10 typical monitoring stations out of 59 monitoring sites, which were representative of aquatic ecosystems, 9 dominant fish species, and 20 dominant invertebrate species. The selection of factors for aquatic ecosystem dependence in Jinan were highly influenced by its regional conditions. Chemical environmental parameters influence the temporal and spatial variation of invertebrate much more than that of fish in Jinan City. However, the methodologies coupling typical monitoring stations selection, dominant species determination and driving factors identification were certified to be a cost-effective way, which can provide in-deep theoretical and technical directions for the restoration of aquatic ecosystems elsewhere.

  16. Survival of enteric bacteria in relation to simulated solar radiation and other environmental factors in marine waters

    International Nuclear Information System (INIS)

    Alkan, U.; Elliott, D.J.; Evison, L.M.

    1995-01-01

    The survival rates of enteric bacteria (i.e. Escherichia coli and enterococci) exposed to a sunlight simulator were determined at two different depths of sea water in varying conditions of light intensity, turbidity, sewage content, degree of mixing and temperature under controlled laboratory conditions. The combined effect of these factors on bacterial die-off was evaluated by statistical analyses carried out on the experimental data obtained according to the central composite experimental design. The magnitude and the general character of the influence of the factors were determined. The variability of bacterial mortality due to the effect of light was shown to depend on the variability of the intensity of light and the other micro environmental factors (i.e. turbidity, sewage content, and mixing) influencing the depth profile of the light intensity and bacterial concentration. All factors except temperature were found to exert a significant influence on bacterial die-off under light conditions. Higher rates of die-off were brought about by high levels of light intensity and mixing with low levels of turbidity and sewage content of the water. No appreciable difference was found between the survival capabilities of E. coli and enterococci on exposure to light. (author)

  17. An application of DEMATEL technique to find the effect of different factors influencing outsourcing activities in water and switch organization

    Directory of Open Access Journals (Sweden)

    Fatimah Hemati

    2012-10-01

    Full Text Available Outsourcing plays an important role on reducing unnecessary activities in any organization and helps focus only on value added activities. Water resource organization in each city is responsible to supply fresh and clean water and dispose switch as efficiently as possible and all citizens normally benefit from these organizations. The proposed model of this paper uses DEMATEL to prioritize 14 different factors influencing on outsourcing activities. The survey was performed from October, 2011 to May, 2012 among employees on work for water resource organization in city of Semnan, Iran. The survey chooses a sample of 92 employees out of 120 people who worked for this organization. Cronbach alpha is calculated as 90%, which is well above the minimum acceptable level. The results of the survey indicate that expediting work process is the most important factor while reducing the cost is considered as the least important factors among 14 different items.

  18. Automated Potentiometric Titrations in KCl/Water-Saturated Octanol: Method for Quantifying Factors Influencing Ion-Pair Partitioning

    Science.gov (United States)

    2009-01-01

    The knowledge base of factors influencing ion pair partitioning is very sparse, primarily because of the difficulty in determining accurate log PI values of desirable low molecular weight (MW) reference compounds. We have developed a potentiometric titration procedure in KCl/water-saturated octanol that provides a link to log PI through the thermodynamic cycle of ionization and partitioning. These titrations have the advantage of being independent of the magnitude of log P, while maintaining a reproducibility of a few hundredths of a log P in the calculated difference between log P neutral and log P ion pair (diff (log PN − I)). Simple model compounds can be used. The titration procedure is described in detail, along with a program for calculating pKa′′ values incorporating the ionization of water in octanol. Hydrogen bonding and steric factors have a greater influence on ion pairs than they do on neutral species, yet these factors are missing from current programs used to calculate log PI and log D. In contrast to the common assumption that diff (log PN − I) is the same for all amines, they can actually vary more than 3 log units, as in our examples. A major factor affecting log PI is the ability of water and the counterion to approach the charge center. Bulky substituents near the charge center have a negative influence on log PI. On the other hand, hydrogen bonding groups near the charge center have the opposite effect by lowering the free energy of the ion pair. The use of this titration method to determine substituent ion pair stabilization values (IPS) should bring about more accurate log D calculations and encourage species-specific QSAR involving log DN and log DI. This work also brings attention to the fascinating world of nature’s highly stabilized ion pairs. PMID:19265385

  19. Automated potentiometric titrations in KCl/water-saturated octanol: method for quantifying factors influencing ion-pair partitioning.

    Science.gov (United States)

    Scherrer, Robert A; Donovan, Stephen F

    2009-04-01

    The knowledge base of factors influencing ion pair partitioning is very sparse, primarily because of the difficulty in determining accurate log P(I) values of desirable low molecular weight (MW) reference compounds. We have developed a potentiometric titration procedure in KCl/water-saturated octanol that provides a link to log P(I) through the thermodynamic cycle of ionization and partitioning. These titrations have the advantage of being independent of the magnitude of log P, while maintaining a reproducibility of a few hundredths of a log P in the calculated difference between log P neutral and log P ion pair (diff (log P(N - I))). Simple model compounds can be used. The titration procedure is described in detail, along with a program for calculating pK(a)'' values incorporating the ionization of water in octanol. Hydrogen bonding and steric factors have a greater influence on ion pairs than they do on neutral species, yet these factors are missing from current programs used to calculate log P(I) and log D. In contrast to the common assumption that diff (log P(N - I)) is the same for all amines, they can actually vary more than 3 log units, as in our examples. A major factor affecting log P(I) is the ability of water and the counterion to approach the charge center. Bulky substituents near the charge center have a negative influence on log P(I). On the other hand, hydrogen bonding groups near the charge center have the opposite effect by lowering the free energy of the ion pair. The use of this titration method to determine substituent ion pair stabilization values (IPS) should bring about more accurate log D calculations and encourage species-specific QSAR involving log D(N) and log D(I). This work also brings attention to the fascinating world of nature's highly stabilized ion pairs.

  20. Identification of factors influencing the restoration of cyanobacteria-dominated biological soil crusts.

    Directory of Open Access Journals (Sweden)

    Chongfeng Bu

    Full Text Available Biological soil crusts (BSCs cover >35% of the Earth's land area and contribute to important ecological functions in arid and semiarid ecosystems, including erosion reduction, hydrological cycling, and nutrient cycling. Artificial rapid cultivation of BSCs can provide a novel alternative to traditional biological methods for controlling soil and water loss such as the planting of trees, shrubs, and grasses. At present, little is known regarding the cultivation of BSCs in the field due to lack of knowledge regarding the influencing factors that control BSCs growth. Thus, we determined the effects of various environmental factors (shade; watering; N, P, K, and Ca concentrations on the growth of cyanobacteria-dominated BSCs from the Sonoran Desert in the southwestern United States. The soil surface changes and chlorophyll a concentrations were used as proxies of BSC growth and development. After 4 months, five factors were found to impact BSC growth with the following order of importance: NH4NO3 ≈ watering frequency>shading>CaCO3 ≈ KH2PO4. The soil water content was the primary positive factor affecting BSC growth, and BSCs that were watered every 5 days harbored greater biomass than those watered every 10 days. Groups that received NH4NO3 consistently exhibited poor growth, suggesting that fixed N amendment may suppress BSC growth. The effect of shading on the BSC biomass was inconsistent and depended on many factors including the soil water content and availability of nutrients. KH2PO4 and CaCO3 had nonsignificant effects on BSC growth. Collectively, our results indicate that the rapid restoration of BSCs can be controlled and realized by artificial "broadcasting" cultivation through the optimization of environmental factors.

  1. Calculation of point isotropic buildup factors of gamma rays for water and lead

    Directory of Open Access Journals (Sweden)

    A. S. H.

    2001-12-01

    Full Text Available   Exposure buildup factors for water and lead have been calculated by the Monte-Carlo method for an isotropic point source in an infinite homogeneous medium, using the latest cross secions available on the Internet. The types of interactions considered are ,photoelectric effect, incoherent (or bound-electron Compton. Scattering, coherent (or Rayleigh scattering and pair production. Fluorescence radiations have also been taken into acount for lead. For each material, calculations were made at 10 gamma ray energies in the 40 keV to 10 MeV range and up to penetration depths of 10 mean free paths at each energy point. The results presented in this paper can be considered as modified gamma ray exposure buildup factors and be used in radiation shielding designs.

  2. Analysis of shallow water experimental acoustic data including normal mode model comparisons

    NARCIS (Netherlands)

    McHugh, R.; Simons, D.G.

    2000-01-01

    Ss part of a propagation model validation exercise experimental acoustic and oceanographic data was collected from a shallow-water, long-range channel, off the west coast of Scotland. Temporal variability effects in this channel were assessed through visual inspection of stacked plots, each of which

  3. Investigating the feasibility of using recycled processed water

    Energy Technology Data Exchange (ETDEWEB)

    Harkness, J. [Urban Systems, Kelowna, BC (Canada)

    2009-07-01

    By the year 2025, 52 countries, with two-thirds of the world's population, are expected to have water shortages. Approximately 3,800 cubic kilometres of fresh water is withdrawn annually from the world's lakes, river and aquifers, which is twice the volume extracted 50 years ago. Water use considerations, alternative water sources, and considerations when using recycled water were discussed in this presentation. A case study of the city of Dawson Creek was provided as it pertained to water reuse in the oil and gas industry. Considerations for recycled water use include health concerns; perception of sewage versus effluent; industrial workers' concerns; and the end product concept. Quality issues were also discussed along with access to water sources, regulations and risks. The case study included a discussion of guiding principles; Dawson Creek's water system; industrial water uses; wastewater system; effluent characteristics; and effluent reuse opportunities. It was concluded that concerns regarding water reuse are not insurmountable providing the driving factors are strong. figs.

  4. Seroprevalence and risk factors associated with exposure of water buffalo (Bubalus bubalis) to Neospora caninum in northeast Thailand.

    Science.gov (United States)

    Kengradomkij, Chanya; Inpankaew, Tawin; Kamyingkird, Ketsarin; Wongpanit, Kannika; Wongnakphet, Sirichai; Mitchell, Thomas J; Xuan, Xuenan; Igarashi, Ikuo; Jittapalapong, Sathaporn; Stich, Roger W

    2015-01-15

    Water buffalo are important draft animals for agriculture in resource-restricted areas worldwide. Water buffalo were shown to be experimentally susceptible to infection with Neospora caninum, potentially affected by neosporosis, and naturally exposed to the parasite in Asia. Although enzootic to Thailand, the distribution of N. caninum among Thai water buffalo is unclear. The objectives of this study were to determine the seroprevalence of N. caninum among water buffalo of northeast Thailand and to identify risk factors associated with their exposure to N. caninum. Sera from 628 water buffalo from 288 farms were tested with an indirect fluorescent antibody test (IFAT). A total of 57 samples from 48 herds contained antibodies to N. caninum, indicating overall seroprevalence of 9.1% and 16.7% among individual animals and herds, respectively. The overall seroprevalence was highest in provinces located in the Khorat Basin in the southern part of the region tested. Host age was also associated with seroprevalence, with the greatest seroprevalence (16.1%) among buffalo over 10 years of age, followed by 5-10 years of age (13.4%), 3-5 years (9.2%), and less than 3 years (1.2%). These results collectively suggested that horizontal transmission from canine definitive hosts was an important route of water buffalo exposure to N. caninum. These results also verified the importance of risk factor analysis for effective bovine neosporosis control strategies at the local level. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Effect of water quality and confounding factors on digestive enzyme activities in Gammarus fossarum.

    Science.gov (United States)

    Charron, L; Geffard, O; Chaumot, A; Coulaud, R; Queau, H; Geffard, A; Dedourge-Geffard, O

    2013-12-01

    The feeding activity and subsequent assimilation of the products resulting from food digestion allow organisms to obtain energy for growth, maintenance and reproduction. Among these biological parameters, we studied digestive enzymes (amylase, cellulase and trypsin) in Gammarus fossarum to assess the impact of contaminants on their access to energy resources. However, to enable objective assessment of a toxic effect of decreased water quality on an organisms' digestive capacity, it is necessary to establish reference values based on its natural variability as a function of changing biotic and abiotic factors. To limit the confounding influence of biotic factors, a caging approach with calibrated male organisms from the same population was used. This study applied an in situ deployment at 23 sites of the Rhone basin rivers, complemented by a laboratory experiment assessing the influence of two abiotic factors (temperature and conductivity). The results showed a small effect of conductivity on cellulase activity and a significant effect of temperature on digestive enzyme activity but only at the lowest temperature (7 °C). The experimental conditions allowed us to define an environmental reference value for digestive enzyme activities to select sites where the quality of the water impacted the digestive capacity of the organisms. In addition to the feeding rate, this study showed the relevance of digestive enzymes as biomarkers to be used as an early warning tool to reflect organisms' health and the chemical quality of aquatic ecosystems.

  6. The Potential Impacts of Climate Change Factors on Freshwater Eutrophication: Implications for Research and Countermeasures of Water Management in China

    Directory of Open Access Journals (Sweden)

    Rui Xia

    2016-03-01

    Full Text Available Water eutrophication has become one of the most serious aquatic environmental problems around the world. More and more research has indicated climate change as a major natural factor that will lead to the acceleration of eutrophication in rivers and lakes. However, understanding the mechanism of climate change’s effect on water eutrophication is difficult due to the uncertainties caused by its complex, non-linear process. There is considerable uncertainty about the magnitude of future temperature changes, and how these will drive eutrophication in water bodies at regional scales under the effect of human activities. This review collects the existing international and domestic literature from the last 10 years, discussing the most sensitive factors of climate change (i.e., temperature, precipitation, wind, and solar radiation and analyzing their interaction with water eutrophication. Case studies of serious eutrophication and algal bloom problems in China are discussed to further demonstrate the conclusion. Finally, adaptation countermeasures and related implications are proposed in order to foster the development of sustainability strategies for water management in China.

  7. Prediction of thermophysical and transport properties of ternary organic non-electrolyte systems including water by polynomials

    Directory of Open Access Journals (Sweden)

    Đorđević Bojan D.

    2013-01-01

    Full Text Available The description and prediction of the thermophysical and transport properties of ternary organic non-electrolyte systems including water by the polynomial equations are reviewed. Empirical equations of Radojković et al. (also known as Redlich-Kister, Kohler, Jacob-Fitzner, Colinet, Tsao-Smith, Toop, Scatchard et al. and Rastogi et al. are compared with experimental data of available papers appeared in well know international journals (Fluid Phase Equilibria, Journal of Chemical and Engineering Data, Journal of Chemical Thermodynamics, Journal of Solution Chemistry, Journal of the Serbian Chemical Society, The Canadian Journal of Chemical Engineering, Journal of Molecular Liquids, Thermochimica Acta, etc.. The applicability of empirical models to estimate excess molar volumes, VE, excess viscosities, ηE, excess free energies of activation of a viscous flow,

  8. Retention of bile salts in micellar electrokinetic chromatography: relation of capacity factor to octanol-water partition coefficient and critical micellar concentration.

    Science.gov (United States)

    Lucangioli, S E; Carducci, C N; Tripodi, V P; Kenndler, E

    2001-12-25

    The capacity factors of 16 anionic cholates (from six bile salts, including their glyco- and tauro-conjugates) were determined in a micellar electrokinetic chromatography (MEKC) system consisting of buffer, pH 7.5 (phosphate-boric acid; 20 mmol/l) with 50 mmol/l sodium dodecyl sulfate (SDS) as micelle former and 10% acetonitrile as organic modifier. The capacity factors of the fully dissociated, negatively charged analytes (ranging between 0.2 and 60) were calculated from their mobilities, with a reference background electrolyte (BGE) without SDS representing "free" solution. For comparison, the capacity factors were derived for a second reference BGE where the SDS concentration (5 mmol/l) is close to the critical micellar concentration (CMC). The capacity factors are compared with the logarithm of the octanol-water partition coefficient, log Pow, as measure for lipophilicity. Clear disagreement between these two parameters is found especially for epimeric cholates with the hydroxy group in position 7. In contrast, fair relation between the capacity factor of the analytes and their CMC is observed both depending strongly on the orientation of the OH groups, and tauro-conjugation as well. In this respect the retention behaviour of the bile salts in MEKC seems to reflect their role as detergents in living systems, and might serve as model parameter beyond lipophilicity.

  9. Measurements of thermal disadvantage factors in light-water moderated PuO2-UO2 and UO2 lattices

    International Nuclear Information System (INIS)

    Ohno, Akio; Kobayashi, Iwao; Tsuruta, Harumichi; Hashimoto, Masao; Suzaki, Takenori

    1980-01-01

    The disadvantage factor for thermal neutrons in light-water moderated PuO 2 -UO 2 and UO 2 square lattices were obtained from measurements of thermal neutron density distributions in a unit lattice cell, measured with Dy-Al wire detectors. The lattices consisted of 3.4 w/o PuO 2 .UO 2 and 2.6 w/o UO 2 fuel rods, and the water-to-fuel volume ratio within the unit cell was parametrically changed. The PuO 2 .UO 2 and UO 2 fuel rods were designed to realize equal fissile atomic number density. The disadvantage factors thus measured were 1.36 +- 0.07, 1.37 +- 0.08, 1.40 +- 0.06 and 1.38 +- 0.06 in the PuO 2 .UO 2 fuel lattices, and 1.30 +- 0.06, 1.31 +- 0.08, 1.30 +- 0.08 and 1.33 +- 0.06 in the UO 2 , for water-to-fuel volume ratios, of 1.76, 2.00, 2.38 and 2.95, respectively. This difference in disadvantage factor between PuO 2 .UO 2 and UO 2 fuel lattices corresponds to about 8%. Calculated results obtained by multigroup transport code LASER agreed well with the measured ones. (author)

  10. Underground coal mine subsidence impacts on surface water

    International Nuclear Information System (INIS)

    Stump, D.E. Jr.

    1992-01-01

    This paper reports that subsidence from underground coal mining alters surface water discharge and availability. The magnitude and areal extent of these impacts are dependent on many factors, including the amount of subsidence, topography, geology, climate, surface water - ground water interactions, and fractures in the overburden. There alterations may have positive and/or negative impacts. One of the most significant surface water impacts occurred in July 1957 near West Pittston, Pennsylvania. Subsidence in the Knox Mine under the Coxton Yards of the Lehigh Valley Railroad allowed part of the discharge in the Susquehanna River to flow into the mine and create a crater 200 feet in diameter and 300 feet deep. Fourteen railroad gondola cars fell into the hole which was eventually filled with rock, sand, and gravel. Other surface water impacts from subsidence may include the loss of water to the ground water system, the gaining of water from the ground water system, the creation of flooded subsidence troughs, the increasing of impoundment storage capacity, the relocation of water sources (springs), and the alteration of surface drainage patterns

  11. Dynamic factor modeling of ground and surface water levels in an agricultural area adjacent to Everglades National Park

    Science.gov (United States)

    Ritter, A.; Muñoz-Carpena, R.

    2006-02-01

    The extensive eastern boundary of Everglades National Park (ENP) in south Florida (USA) is subject to one the most expensive and ambitious environmental restoration projects in history. Understanding and predicting the interaction between the shallow aquifer and surface water is a key component for fine-tuning the process. The Frog Pond is an intensively instrumented agricultural 2023 ha area adjacent to ENP. The interactions among 21 multivariate daily time series (ground and surface water elevations, rainfall and evapotranspiration) available from this area were studied by means of dynamic factor analysis, a novel technique in the field of hydrology. This method is designed to determine latent or background effects governing variability or fluctuations in non-stationary time series. Water levels in 16 wells and two drainage ditch locations inside the area were selected as response variables, and canal levels and net recharge as explanatory variables. Elevations in the two canals delimiting the Frog Pond area were found to be the main factors explaining the response variables. This influence of canal elevations on water levels inside the area was complementary and inversely related to the distance between the observation point and each canal. Rainfall events do not affect daily water levels significantly but are responsible for instantaneous or localized groundwater responses that in some cases can be directly associated with the risk of flooding. This close coupling between surface and groundwater levels, that corroborates that found by other authors using different methods, could hinder on-going environmental restoration efforts in the area by bypassing the function of wetlands and other surface features. An empirical model with a reduced set of parameters was successfully developed and validated in the area by interpolating the results from the dynamic factor analysis across the spatial domain (coefficient of efficiency across the domain: 0.66-0.99). Although

  12. WATER-TRAPPED WORLDS

    International Nuclear Information System (INIS)

    Menou, Kristen

    2013-01-01

    Although tidally locked habitable planets orbiting nearby M-dwarf stars are among the best astronomical targets to search for extrasolar life, they may also be deficient in volatiles and water. Climate models for this class of planets show atmospheric transport of water from the dayside to the nightside, where it is precipitated as snow and trapped as ice. Since ice only slowly flows back to the dayside upon accumulation, the resulting hydrological cycle can trap a large amount of water in the form of nightside ice. Using ice sheet dynamical and thermodynamical constraints, I illustrate how planets with less than about a quarter the Earth's oceans could trap most of their surface water on the nightside. This would leave their dayside, where habitable conditions are met, potentially dry. The amount and distribution of residual liquid water on the dayside depend on a variety of geophysical factors, including the efficiency of rock weathering at regulating atmospheric CO 2 as dayside ocean basins dry up. Water-trapped worlds with dry daysides may offer similar advantages as land planets for habitability, by contrast with worlds where more abundant water freely flows around the globe

  13. WATER-TRAPPED WORLDS

    Energy Technology Data Exchange (ETDEWEB)

    Menou, Kristen [Department of Astronomy, Columbia University, 550 West 120th Street, New York, NY 10027 (United States)

    2013-09-01

    Although tidally locked habitable planets orbiting nearby M-dwarf stars are among the best astronomical targets to search for extrasolar life, they may also be deficient in volatiles and water. Climate models for this class of planets show atmospheric transport of water from the dayside to the nightside, where it is precipitated as snow and trapped as ice. Since ice only slowly flows back to the dayside upon accumulation, the resulting hydrological cycle can trap a large amount of water in the form of nightside ice. Using ice sheet dynamical and thermodynamical constraints, I illustrate how planets with less than about a quarter the Earth's oceans could trap most of their surface water on the nightside. This would leave their dayside, where habitable conditions are met, potentially dry. The amount and distribution of residual liquid water on the dayside depend on a variety of geophysical factors, including the efficiency of rock weathering at regulating atmospheric CO{sub 2} as dayside ocean basins dry up. Water-trapped worlds with dry daysides may offer similar advantages as land planets for habitability, by contrast with worlds where more abundant water freely flows around the globe.

  14. Experimental investigation of the effect of latex solid/water ratio on latex modified co-matrix mechanical properties

    Directory of Open Access Journals (Sweden)

    Ahmed M. Diab

    2013-03-01

    Full Text Available Numerous researches were performed on latex modified concretes and associated properties, however; some vital factors were not given attention in previous works. This study focus on new factor which significantly affects the properties of latex modified cement paste, mortar or concrete. This factor is termed as ‘latex solid/water ratio’ which is defined herein as the ratio of weight of solid latex to weight of total water content of cement composite including the water in latex itself. The effect of this factor on some properties of cement paste, mortar and concrete were experimentally evaluated. Properties of cement paste include the produced calcium hydroxide and ettringite content during hydration process, while those of cement mortar take account of absorption and effect of temperature on compressive strength. Furthermore, the effect of this factor on the compressive and flexural strengths, modulus of elasticity, water penetration depth and drying shrinkage of concrete were explored. Based on experimental evidences, and spite of using different cement contents, sources of latex, water–cement ratios and slump values, it can be generally concluded that the latex solid/water ratio is a dominant factor affecting different properties of latex modified mortars and concrete.

  15. Analysis of factors causing signal loss in the measurement of lung tissue water by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Fukuzaki, Minoru; Shioya, Sumie; Haida, Munetaka

    1997-01-01

    The water content of lung, brain, and muscle tissue was measured by nuclear magnetic resonance (NMR) and compared with gravimetric determinations. The NMR signal intensity of water was measured by a single 90 degree pulse and by a spin-echo sequence. The absolute water content was determined by the difference in the sample's weight before and after desiccation. The NMR detectable water in each tissue was expressed as a percentage of the signal intensity for an equal weight of distilled water. Using the single pulse measurement, 67% of the gravimetrically-measured water was detected in collapsed lung samples (consisting of about 47% retained air), in contrast to 96% for brain and 98% for muscle. For degassed lung samples, the NMR detectability of water increased to 87% with the single pulse measurement and to 90% with the spin-echo measurement, but the values remained significantly less than those of brain or muscle. Factors that caused the NMR signal loss of 33% in collapsed lung samples were: air-tissue interfaces (20%), microscopic field inhomogeneity (3%), and a water component with an extremely short magnetization decay time constant (10%). (author)

  16. Using Personal Water Footprints to Identify Consumer Food Choices that Influence the Conservation of Local Water Resources

    Science.gov (United States)

    Marrin, D. L.

    2015-12-01

    As the global demand for water and food escalates, the emphasis is on supply side factors rather than demand side factors such as consumers, whose personal water footprints are dominated (>90%) by food. Personal footprints include the water embedded in foods that are produced locally as well as those imported, raising the question of whether local shifts in people's food choices and habits could assist in addressing local water shortages. The current situation in California is interesting in that drought has affected an agriculturally productive region where a substantial portion of its food products are consumed by the state's large population. Unlike most agricultural regions where green water is the primary source of water for crops, California's arid climate demands an enormous volume of blue water as irrigation from its dwindling surface and ground water resources. Although California exports many of its food products, enough is consumed in-state so that residents making relatively minor shifts their food choices could save as much local blue water as their implementing more drastic reductions in household water use (comprising food group on both a caloric and gravimetric basis. Another change is wasting less food, which is a shared responsibility among consumers, producers and retailers; however, consumers' actions and preferences ultimately drive much of the waste. Personal water footprints suggest a role for individuals in conserving local water resources that is neither readily obvious nor a major focus of most conservation programs.

  17. Demineralised water cooling in the LHC accelerator

    CERN Document Server

    Peón-Hernández, G

    2002-01-01

    In spite of the LHC accelerator being a cryogenic machine, it remains nevertheless a not negligible heat load to be removed by conventional water-cooling. About 24MW will be taken away by demineralised water cooled directly by primary water from the LHC cooling towers placed at the even points. This paper describes the demineralised water network in the LHC tunnel including pipe diameters, lengths, water speed, estimated friction factor, head losses and available supply and return pressures for each point. It lists all water cooled equipment, highlights the water cooled cables as the most demanding equipment followed by the radio frequency racks and cavities, and by the power converters. Their main cooling requirements and their positions in the tunnel are also presented.

  18. High-throughput sequencing reveals microbial communities in drinking water treatment sludge from six geographically distributed plants, including potentially toxic cyanobacteria and pathogens.

    Science.gov (United States)

    Xu, Hangzhou; Pei, Haiyan; Jin, Yan; Ma, Chunxia; Wang, Yuting; Sun, Jiongming; Li, Hongmin

    2018-04-10

    The microbial community structures of drinking water treatment sludge (DWTS) generated for raw water (RW) from different locations and with different source types - including river water, lake water and reservoir water -were investigated using high-throughput sequencing. Because the unit operations in the six DWTPs were similar, community composition in fresh sludge may be determined by microbial community in the corresponding RW. Although Proteobacteria, Cyanobacteria, Bacteroidetes, Firmicutes, Verrucomicrobia, and Planctomycetes were the dominant phyla among the six DWTS samples, no single phylum exhibited similar abundance across all the samples, owing to differences in total phosphorus, chemical oxygen demand, Al, Fe, and chloride in RW. Three genera of potentially toxic cyanobacteria (Planktothrix, Microcystis and Cylindrospermopsis), and four potential pathogens (Escherichia coli, Bacteroides ovatus, Prevotella copri and Rickettsia) were found in sludge samples. Because proliferation of potentially toxic cyanobacteria and Rickettsia in RW was mainly affected by nutrients, while growth of Escherichia coli, Bacteroides ovatus and Prevotella copri in RW may be influenced by Fe, control of nutrients and Fe in RW is essential to decrease toxic cyanobacteria and pathogens in DWTS. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Management of scarce water resources: a Middle Eastern experience

    National Research Council Canada - National Science Library

    El-Naser, H

    2009-01-01

    .... Research in these regions has long supported the necessity of delivering life sustaining access and availability to water while being inherently linked to several inter-related factors, including...

  20. Air radon equilibrium factor measurement in a Waste Water Pre-Treatment Plant

    International Nuclear Information System (INIS)

    Martinez, J.E.; Juste, B.; Ortiz, J.; Martorell, S.; Verdu, G.

    2017-01-01

    We analyze in this paper a Waste Water Pre-Treatment Plant (WWTP) located at the Mediterranean coast with air radon concentration above Spanish action level (600 Bq per cubic meter). This paper presents a method for radon equilibrium determination by gamma spectrometry measuring of the radon progeny concentrations in the air, in order to estimate WWTP workers effective dose more exactly. The method is based on simultaneous sampling of air through a filter paper and alpha spectrometry measurement of radon activity concentration in the air. According to the measured radon activity concentration in the air of 368±45 Bq/m 3 the equilibrium factor between radon and progenies is estimated to be F=0.27, which is in good agreement with expected values. - Highlights: • High levels of Radon in a workplace can increase health risks in the employees. • Using the typical equilibrium factor 0.4 could lead to an error in the estimation of radon doses. • We present a method for radon equilibrium determination. • Equilibrium factor is calculated by gamma spectrometry measuring of radon progeny concentrations in the air.

  1. Quantitative Analysis on the Influence Factors of the Sustainable Water Resource Management Performance in Irrigation Areas: An Empirical Research from China

    Directory of Open Access Journals (Sweden)

    Hulin Pan

    2018-01-01

    Full Text Available Performance evaluation and influence factors analysis are vital to the sustainable water resources management (SWRM in irrigation areas. Based on the objectives and the implementation framework of modern integrated water resources management (IWRM, this research systematically developed an index system of the performances and their influence factors ones of the SWRM in irrigation areas. Using the method of multivariate regression combined with correlation analysis, this study estimated quantitatively the effect of multiple factors on the water resources management performances of irrigation areas in the Ganzhou District of Zhangye, Gansu, China. The results are presented below. The overall performance is mainly affected by management enabling environment and management institution with the regression coefficients of 0.0117 and 0.0235, respectively. The performance of ecological sustainability is mainly influenced by local economic development level and enable environment with the regression coefficients of 0.08642 and −0.0118, respectively. The performance of water use equity is mainly influenced by information publicity, administrators’ education level and ordinary water users’ participation level with the correlation coefficients of 0.637, 0.553 and 0.433, respectively. The performance of water use economic efficiency is mainly influenced by the management institutions and instruments with the regression coefficients of −0.07844 and 0.01808, respectively. In order to improve the overall performance of SWRM in irrigation areas, it is necessary to strengthen the public participation, improve the manager’ ability and provide sufficient financial support on management organization.

  2. Characterization of water-forming NADH oxidases for co-factor regeneration

    DEFF Research Database (Denmark)

    Rehn, Gustav; Pedersen, Asbjørn Toftgaard; J. Charnock, Simon

    an environmentaland economic perspective [1]. Alcohol dehydrogenases (ADH) offer one such alternative. However, the reaction requires the oxidized nicotinamide co-factor (NAD+) that must be recycled due to its high cost contribution. One regeneration method that offers certain advantages is the oxidation of NADH......Traditional chemical methods for alcohol oxidation are often associated with issues such as high consumption of expensive oxidizing agents, generation of metal waste and the use of environmentally undesirable organic solvents. Developing green, selective catalysts is therefore important from...... using water forming NADH oxidases (NOX-2). The implementation of the ADH/NOX system for alcohol oxidation, however, requires consideration of several different issues. Enzyme activity and stability at relevant pH and temperature conditions, but also the tolerance to the substrates and products present...

  3. A REVIEW OF EPIDEMIOOGICAL STUDIES ON DRINKING WATER HARDNESS AND CARDIOVASCULAR DISEASES

    Science.gov (United States)

    Major risk factors do not entirely explain the worldwide variability of morbidity and mortality due tocardiovascular disease. Several environmental factors, including the hardness of drinking water mayaffect cardiovascular disease risks. We conducted a qualitative...

  4. Water: The Only Factor Influencing the Price of Energy in the Spot Market?

    Directory of Open Access Journals (Sweden)

    Vinicius Mothé Maia

    2016-04-01

    Full Text Available The Brazilian electric energy generation system is based on its hydroelectric power plants, making the country dependent on proper rainfall and, thus, raising the possibility of energy stress situations, such as the energy-rationing scenario observed in the beginning of the century and the latest water crisis (2014. Moments of water scarcity are followed by an increase in energy prices, which affects the economy as whole. Therefore, it is relevant to understand which factors in the Brazilian Electric System affect the energy price and the individual importance of each. This paper aimed to analyze which the key variables influencing the energy price in the spot market are by using official data from the National Electric System Operator. The used data was from the period July/2001 to July/2014, which was employed in a multiple regression methodology along with time series. The results suggest an inverse relationship between the natural flow of rivers (directly related to rainfall and the energy price. Moreover, they also point to an inverse relationship between the potential energy stored in reservoirs as water and the energy price.

  5. Participation in water-exercising long-term after breast cancer surgery: Experiences of significant factors for continuing exercising as a part of cancer rehabilitation.

    Science.gov (United States)

    Enblom, A; Lindquist, H; Bergmark, K

    2018-01-01

    Although physical exercising has great benefits, little is known regarding factors of significance for cancer survivors to continue exercising within their rehabilitation. The objective was to describe factors experienced to be of significance for cancer survivors to continue with water-exercising long-term after breast cancer surgery. Women (n = 29) who had undergone breast cancer surgery (mastectomy 79%, axillary surgery 86%, and radiotherapy 86%) for median (md) 13 (25th-75th percentile 3-21.5) was followed up regarding their rehabilitation, arm function Disabilities of Arm Shoulder and Hand (md 14, IQR 7-32), EQ-5D score (md 0.8, IQR 0.73-1.0) and quality of life EQ health barometer (md 80, IQR 64-95). We performed qualitative focus-group interviews regarding the women's views (n = 24). The women had participated in water-exercising 1-46 semesters, md 8 (25th-75th percentile 3-21.5) semesters. Nearly all, 97%, participated in the water-exercising group every week, and 21 (72%) had participated in the water-exercising group at least half of the time since their breast cancer surgery, without complications. The women experienced that factors of significance to continue with water-exercising were the convenience of easily modified weightless exercising in the water, social interaction, and access to a private dressing room. These factors would be important to consider to encourage continuing in exercising. © 2017 John Wiley & Sons Ltd.

  6. Effect of water content on strontium retardation factor and distribution coefficient in Chinese loess.

    Science.gov (United States)

    Huo, Lijuan; Qian, Tianwei; Hao, Junting; Liu, Hongfang; Zhao, Dongye

    2013-12-01

    Geological burial and landfill are often employed for disposal of nuclear wastes. Typically, radionuclides from nuclear facilities transport through the unsaturated zone before reaching the groundwater aquifer. However, transport studies are often conducted under saturated and steady-state flow conditions. This research aimed to examine the effects of unsaturated flow conditions and soil water content (θ) on Sr sorption and retardation in Chinese loess through 1D column transport experiments. Reagent SrCl2 was used as a surrogate for the radioactive isotope ((90)Sr) in the experiment because of their analogous adsorption and transportation characteristics. The spatial distribution of Sr along the column length was determined by segmenting the soil bed and analysing the Sr content in each soil segment following each column breakthrough test. The single-region (SR) and two-region (TR) models were employed to interpret the transport data of Sr as well as a tracer (Br(-)), which resulted in the dispersion coefficient (D) and retardation factor (Rd) under a given set of unsaturated flow conditions. For the tracer, the SR and TR models offered nearly the same goodness of fitting to the breakthrough curves (R(2) ≈ 0.97 for both models). For the highly sorptive Sr, however, the TR model provided better fitting (R(2), 0.80-0.96) to the Sr retention profiles than the SR model (R(2), 0.20-0.89). The Sr retention curves exhibited physical non-equilibrium characteristics, particularly at lower water content of the soil. For the unsaturated soil, D and the pore water velocity (v) displayed a weak linear correlation, which is attributed to the altering dispersivity as the water content varies. A much improved linear correlation was observed between D and v/θ. The retardation factor of Sr increased from 69.1 to 174.2 as θ decreased from 0.46 to 0.26 (cm(3) cm(-3)), while the distribution coefficient (Kd) based on Rd remained nearly unchanged at various θ levels. These

  7. Water-contact patterns and risk factors for Schistosoma mansoni infection in a rural village of Northeast Brazil

    Directory of Open Access Journals (Sweden)

    SILVA Antônio Augusto Moura da

    1997-01-01

    Full Text Available Schistosomiasis mansoni in the Serrano village, municipality of Cururupu, state of Maranhão, Brazil, is a widely spread disease. The PECE (Program for the Control of Schistosomiasis, undertaken since 1979 has reduced the prevalence of S. mansoni infection and the hepatosplenic form of the disease. Nevertheless piped water is available in 84% of the households, prevalence remains above 20%. In order to identify other risk factors responsible for the persistence of high prevalence levels, a cross-sectional survey was carried out in a systematic sample of 294 people of varying ages. Socioeconomic, environmental and demographic variables, and water contact patterns were investigated. Fecal samples were collected and analyzed by the Kato-Katz technique. Prevalence of S. mansoni infection was 24.1%, higher among males (35.5% and between 10-19 years of age (36.6%. The risk factors identified in the univariable analysis were water contacts for vegetable extraction (Risk Ratio - RR = 2.92, crossing streams (RR = 2.55, bathing (RR = 2.35, fishing (RR = 2.19, hunting (RR = 2.17, cattle breeding (RR = 2.04, manioc culture (RR = 1.90 and leisure (RR = 1.56. After controlling for confounding variables by proportional hazards model the risks remained higher for males, vegetable extraction, bathing in rivers and water contact in rivers or in periodically inundated parts of riverine woodland (swamplands

  8. Fly ash dynamics in soil-water systems

    International Nuclear Information System (INIS)

    Sharma, S.; Fulekar, M.H.; Jayalakshmi, C.P.

    1989-01-01

    Studies regarding the effluents and coal ashes (or fly ash) resulting from coal burning are numerous, but their disposal and interactions with the soil and water systems and their detailed environmental impact assessment with concrete status reports on a global scale are scanty. Fly ash dynamics in soil and water systems are reviewed. After detailing the physical composition of fly ash, physicochemical changes in soil properties due to fly ash amendment are summarized. Areas covered include texture and bulk density, moisture retention, change in chemical equilibria, and effects of fly ash on soil microorganisms. Plant growth in amended soils is discussed, as well as plant uptake and accumulation of trace elements. In order to analyze the effect of fly ash on the physicochemical properties of water, several factors must be considered, including surface morphology of fly ash, pH of the ash sluice water, pH adjustments, leachability and solubility, and suspended ash and settling. The dynamics of fly ash in water systems is important due to pollution of groundwater resources from toxic components such as trace metals. Other factors summarized are bioaccumulation and biomagnification, human health effects of contaminants, and the impact of radionuclides in fly ash. Future research needs should focus on reduction of the environmental impact of fly ash and increasing utilization of fly ash as a soil amendment. 110 refs., 2 figs., 10 tabs

  9. Water quality studied in areas of unconventional oil and gas development, including areas where hydraulic fracturing techniques are used, in the United States

    Science.gov (United States)

    Susong, David D.; Gallegos, Tanya J.; Oelsner, Gretchen P.

    2012-01-01

    Domestic oil and gas production and clean water are critical for economic growth, public health, and national security of the United States. As domestic oil and gas production increases in new areas and old fields are enhanced, there is increasing public concern about the effects of energy production on surface-water and groundwater quality. To a great extent, this concern arises from the improved hydraulic fracturing techniques being used today, including horizontal drilling, for producing unconventional oil and gas in low-permeability formations.

  10. A review of cell-scale multiphase flow modeling, including water management, in polymer electrolyte fuel cells

    International Nuclear Information System (INIS)

    Andersson, M.; Beale, S.B.; Espinoza, M.; Wu, Z.; Lehnert, W.

    2016-01-01

    Highlights: • The transport expressions inside PEFC GDLs are developed to describe significantly different systems. • Insight into the fundamental processes of liquid water evolution and transport in the GDL and GC is still lacking. • One important feature is the possibility to track the front between the liquid and the gas phases. • The two phase micro channels pressure drop correlations may not be applicable for GCs since one wall being porous. - Abstract: The PEFC has emerged as the most viable fuel cell type for automotive and some portable applications, and also has potential back-up power unit applications due to its low operating temperature, comparative simplicity of construction, high power density, and ease of operation. In spite of tremendous scientific advances, as well as engineering progress over the last few decades, the commercialization of PEFCs remains unrealized, owing primarily to economic viability associated with the high prices of materials and components and technical problems relating primarily to water management. The difficulty in addressing the water management issues lies mostly in the two-phase multi-component flow involving phase-change in porous media, coupled heat and mass transfer, interactions between the porous layers and gas channel (GC) and the complex relationship between water content and cell performance. Due to the low temperature of operation, water generated by the electrochemical reactions often condenses into liquid form, potentially flooding the gas diffusion layer (GDL), GC or other components. Insight into the fundamental processes of liquid water evolution and transport is still lacking, preventing further enhanced PEFC development. The aim of this paper is to give a comprehensive introduction to PEFC modeling inside GCs and GDLs, with a focus on two-phase flow and related phase-change and transport processes. Relevant momentum, mass and heat transport processes are introduced and the microstructural effects

  11. Service water system repair/replacement guidelines: Planning and implementation

    International Nuclear Information System (INIS)

    Frederick, G.J.; Gandy, D.W.; Peterson, A.G. Jr.; Findlan, S.J.

    1993-11-01

    Service water system failures have prompted concerns related to extended power plant operating life and plant availability. Selection and procurement of materials for repair or replacement of piping and components may be the most important factors in improving service water system reliability. The authors examined factors that contribute to reduced SWS reliability. The factors include material selection inadequacies, water treatment problems, operational/maintenance practices, fabrication procedures, environmental degradation mechanisms, and coating problems. The authors investigated material selection for replacement and repair, taking into account fabrication practices, environmental concerns, and cost comparisons of materials. They examined specific components such as piping, pumps, valves, and heat exchangers with regard to material selection and fabrication practice. Although proper material selection is essential in upgrading and maintaining the designed functions of a SWS, it is critical to address SWS repair/replacement activities with a systemwide approach. Degradation of materials in SWS applications are plant specific, depending on factors unique to each site such as geographic location, existing materials, operating procedures, and environment. All these characteristics must be addressed in making repair/replacement decisions. Criteria that must be integrated for successful long-term operation of SWS include the following: Materials selection (upgrade or in-kind replacement), Evaluation of root cause or nature of the failure mechanism, Scope of the repair/replacement activities, Material compatibility of the existing materials, Operational and maintenance procedures, Code or jurisdictional requirements, Economic considerations, Water treatment programs, System design improvements or modifications

  12. Some factors affecting the distribution of radon

    International Nuclear Information System (INIS)

    Grainger, C.R.

    1986-01-01

    The importance of the distribution of radon in the natural background radiation exposures for man is stressed. Factors which effect the distribution include the origin of the rocks, the permeability of the rocks, fractures in the rocks and ground water flow. (U.K.)

  13. Clean water, Sanitation and Diarrhoea in Indonesia: Effects of Household and Community Factors

    NARCIS (Netherlands)

    Komarulzaman, A.; Smits, J.P.J.M.; Jong, E. de

    2017-01-01

    Diarrhoea is an important health issue in low- and middle-income countries, including Indonesia. We applied a multilevel regression analysis on the Indonesian Demographic and Health Survey to examine the effects of drinking water and sanitation facilities at the household and community level on

  14. Factors affecting the long-term response of surface waters to acidic deposition: state-of-the-science

    Energy Technology Data Exchange (ETDEWEB)

    Turner, R.S.; Johnson, D.W.; Elwood, J.N.; Van Winkle, W.; Clapp, R.B.; Jones, M.L.; Marmarek, D.R.; Thornton, K.W.; Gherinig, S.A.; Schnoor, J.L.

    1986-01-01

    Recent intensive study of the causes of surface water acidification has led to numerous hypothesized controlling mechanisms. Among these are the salt-effect reduction of alkalinity, the base cation buffering and sulfate adsorption capacities of soils, availability of weatherable minerals (weathering rates), depth of till, micropore flow, and type of forest cover. Correlative and predictive models have been developed to show the relationships (if any) between hypothesized controlling mechanisms and surface water acidity, and to suggest under what conditions additional surface water might become acid. This document (Part A) is a review of our current knowledge of factors and processes controlling soil and surface water acidification, as well as an assessment of the adequacy of that knowledge for making predictions of future acidification. Section 2 is a data extensive, conceptual overview of how watersheds function. Section 3 is a closer look at the theory and evidence for the key hypotheses. Section 4 is a review of existing methods of assessing system response to acidic deposition.

  15. Regulation of hippocampal neurogenesis by systemic factors including stress, glucocorticoids, sleep, and inflammation

    NARCIS (Netherlands)

    Lucassen, P.J.; Oomen, C.; van Dam, A.-M.; Czéh, B.; Gage, F.H.; Kempermann, G.; Song, H.

    2008-01-01

    This review summarizes and discusses the regulation of adult neurogenesis and hippocampal cellular plasticity by systemic factors. We focus on the role of stress, glucocorticoids, and related factors such as sleep deprivation and inflammation.

  16. A water-based training program that include perturbation exercises to improve stepping responses in older adults: study protocol for a randomized controlled cross-over trial

    Directory of Open Access Journals (Sweden)

    Tsedek Irit

    2008-08-01

    Full Text Available Abstract Background Gait and balance impairments may increase the risk of falls, the leading cause of accidental death in the elderly population. Fall-related injuries constitute a serious public health problem associated with high costs for society as well as human suffering. A rapid step is the most important protective postural strategy, acting to recover equilibrium and prevent a fall from initiating. It can arise from large perturbations, but also frequently as a consequence of volitional movements. We propose to use a novel water-based training program which includes specific perturbation exercises that will target the stepping responses that could potentially have a profound effect in reducing risk of falling. We describe the water-based balance training program and a study protocol to evaluate its efficacy (Trial registration number #NCT00708136. Methods/Design The proposed water-based training program involves use of unpredictable, multi-directional perturbations in a group setting to evoke compensatory and volitional stepping responses. Perturbations are made by pushing slightly the subjects and by water turbulence, in 24 training sessions conducted over 12 weeks. Concurrent cognitive tasks during movement tasks are included. Principles of physical training and exercise including awareness, continuity, motivation, overload, periodicity, progression and specificity were used in the development of this novel program. Specific goals are to increase the speed of stepping responses and improve the postural control mechanism and physical functioning. A prospective, randomized, cross-over trial with concealed allocation, assessor blinding and intention-to-treat analysis will be performed to evaluate the efficacy of the water-based training program. A total of 36 community-dwelling adults (age 65–88 with no recent history of instability or falling will be assigned to either the perturbation-based training or a control group (no training

  17. Numerical Calculation of the Peaking Factor of a Water-Cooled W/Cu Monoblock for a Divertor

    International Nuclear Information System (INIS)

    Han Le; Chang Haiping; Zhang Jingyang; Xu Tiejun

    2015-01-01

    In order to accurately predict the incident critical heat flux (ICHF, the heat flux at the heated surface when CHF occurs) of a water-cooled W/Cu monoblock for a divertor, the exact knowledge of its peaking factors (f p ) under one-sided heating conditions with different design parameters is a key issue. In this paper, the heat conduction in the solid domain of a water-cooled W/Cu monoblock is calculated numerically by assuming the local heat transfer coefficients (HTC) of the cooling wall to be functions of the local wall temperature, so as to obtain f p . The reliability of the calculation method is validated by an experimental example result, with the maximum error of 2.1% only. The effects of geometric and flow parameters on the f p of a water-cooled W/Cu monoblock are investigated. Within the scope of this study, it is shown that the f p increases with increasing dimensionless W/Cu monoblock width and armour thickness (the shortest distance between the heated surface and Cu layer), and the maximum increases are 43.8% and 22.4% respectively. The dimensionless W/Cu monoblock height and Cu thickness have little effect on f p . The increase of Reynolds number and Jakob number causes the increase of f p , and the maximum increases are 6.8% and 9.6% respectively. Based on the calculated results, an empirical correlation on peaking factor is obtained via regression. These results provide a valuable reference for the thermal-hydraulic design of water-cooled divertors. (paper)

  18. Quantification of renal cortical blood flow using factor analysis of O-15 water dynamic PET images

    International Nuclear Information System (INIS)

    Seo, Kang Jun; Ahn, Ji Young; Lee, Jae Sung; Paeng, Jin Chul; Cheon, Gi Jeong; Lee, Dong Soo; Noh, Tae Won; Chung, June Key; Lee, Myung Chul

    2000-01-01

    To obtain spatial distribution of renal factor images, input function, and regional tissue time-activity curve (TAC) from O-15 water dynamic PET images non-invasively, factor analysis (FA) was used. O-15 water dynamic PET scans were performed on 3 normal dogs (22 ∼ 29 kg) with the bolus injection of O-15 water (555 ∼ 740 Mbq). We performed FA on the masked dynamic images and obtained the pure TACs and the corresponding factor images. Microsphere experiment also was performed. 37MBq of microsphere labeled with Sc-46 was injected into the left ventricle. Arterial input functions derived from the PET images using FA were compared with the invasively derived arterial blood samples. The renal cortical blood flow using the TACs by FA was within the normal range of 1.23 ∼ 2.46 ml/min/g. In microsphere study, the renal cortical blood flow of left kidney by FA was 2.49±0.47 ml/min/g (1.81∼2.90 ml/min/g) and by microsphere was 2.52 ±0.19 ml/min/g (2.34 ∼2.68 ml/min/g). In right kidney, flow by FA was 2.02 ±0.32 ml/min/g (1.82∼2.49 ml/min/g) and by microsphere was 2.49 ±0.27 ml/min/g (2.02∼2.7). FA is a useful and robust method to extract input functions and tissue TACs from O-15 dynamic renal PET. Renal cortical blood flow can be estimated non-invasively using FA and it will be helpful for the assessment of renal functional disease

  19. Dosimetric characteristics of water equivalent for two solid water phantoms

    International Nuclear Information System (INIS)

    Wang Jianhua; Wang Xun; Ren Jiangping

    2011-01-01

    Objective: To investigate the water equivalent of two solid water phantoms. Methods: The X-ray and electron beam depth-ion curves were measured in water and two solid water phantoms, RW3 and Virtual Water. The water-equivalency correction factors for the two solid water phantoms were compared. We measured and calculated the range sealing factors and the fluence correction factors for the two solid water phantoms in the case of electron beams. Results: The average difference between the measured ionization in solid water phantoms and water was 0.42% and 0.16% on 6 MV X-ray (t=-6.15, P=0.001 and t=-1.65, P=0.419) and 0.21% and 0.31% on 10 MV X-ray (t=1.728, P=0.135 and t=-2.296, P=0.061), with 17.4% and 14.5% on 6 MeV electron beams (t=-1.37, P=0.208 and t=-1.47, P=0.179) and 7.0% and 6.0% on 15 MeV electron beams (t=-0.58, P=0.581 and t=-0.90, P=0.395). The water-equivalency correction factors for the two solid water phantoms varied slightly largely, F=58.54, P=0.000 on 6 MV X-ray, F=0.211, P=0.662 on 10 MV X-ray, F=0.97, P=0.353 on 6 MeV electron beams, F=0.14, P=0.717 on 15 MeV electron beams. However, they were almost equal to 1 near the reference depths. The two solid water phantoms showed a similar tread of C pl increasing (F=26.40, P=0.014) and h pl decreasing (F=7.45, P=0.072) with increasing energy. Conclusion: The solid water phantom should undergo a quality control test before being clinical use. (authors)

  20. Land and Water Use, CO2 Emissions, and Worker Radiological Exposure Factors for the Nuclear Fuel Cycle

    Energy Technology Data Exchange (ETDEWEB)

    Brett W Carlsen; Brent W Dixon; Urairisa Pathanapirom; Eric Schneider; Bethany L. Smith; Timothy M. AUlt; Allen G. Croff; Steven L. Krahn

    2013-08-01

    The Department of Energy Office of Nuclear Energy’s Fuel Cycle Technologies program is preparing to evaluate several proposed nuclear fuel cycle options to help guide and prioritize Fuel Cycle Technology research and development. Metrics are being developed to assess performance against nine evaluation criteria that will be used to assess relevant impacts resulting from all phases of the fuel cycle. This report focuses on four specific environmental metrics. • land use • water use • CO2 emissions • radiological Dose to workers Impacts associated with the processes in the front-end of the nuclear fuel cycle, mining through enrichment and deconversion of DUF6 are summarized from FCRD-FCO-2012-000124, Revision 1. Impact estimates are developed within this report for the remaining phases of the nuclear fuel cycle. These phases include fuel fabrication, reactor construction and operations, fuel reprocessing, and storage, transport, and disposal of associated used fuel and radioactive wastes. Impact estimates for each of the phases of the nuclear fuel cycle are given as impact factors normalized per unit process throughput or output. These impact factors can then be re-scaled against the appropriate mass flows to provide estimates for a wide range of potential fuel cycles. A companion report, FCRD-FCO-2013-000213, applies the impact factors to estimate and provide a comparative evaluation of 40 fuel cycles under consideration relative to these four environmental metrics.

  1. Factors that affect public-supply water use in Florida, with a section on projected water use to the year 2020

    Science.gov (United States)

    Marella, R.L.

    1992-01-01

    Public-supply water use in Florida increased 242 percent between 1960 and 1987 from 530 Mgal/d (million gallons per day) to 1,811 Mgal/d. This change is primarily a result of increases in population and tourism since 1960. Public-supply utilities provide water to a variety of users. In 1985, 71 percent of the water used for public supply was delivered for residential uses, 15 percent for commercial uses, 9 percent for industrial uses, and the remaining 5 percent for public use or other uses. Residential use of public-supply water in Florida has increased nearly 280 Mgal/d, but has decreased in the proportion of total deliveries from 80 to 71 percent between 1975 and 1985. This trend resulted from increased tourism and related commercial services associated with population and visitors. One of several factors that influences public-supply water use in Florida is the increase in resident population, which increased from 4.95 million in 1960 to more than 12.0 million in 1987. Additionally, Florida's nonresident population increased from 18.8 million visitors in 1977, to 34.1 million visitors in 1987, and the part of Florida?s population that relies on public-supply water increased from 68 percent in 1960, to 86 percent in 1987. The public supply per capita use was multiplied by the projected populations for each county for the years 2000, 2010, and 2020 to forecast public-supply water use. Using medium projections, Florida?s population is expected to increase to nearly 16 million in the year 2000, to 18 million in the year 2010, and to almost 20 million in the year 2020, of which an estimated 13.5 million people will be supplied water from public-supply water systems in the year 2000, 15 million in 2010, and nearly 17 million by the year 2020. Public-supply water use is expected to increase to a projected (medium) 2,310 Mgal/d in the year 2000, 2,610 Mgal/d in the year 2010, and 2,890 Mgal/d in the year 2020. If the population exceeds the medium projections for the

  2. Parasitism can be a confounding factor in assessing the response of zebra mussels to water contamination

    International Nuclear Information System (INIS)

    Minguez, Laëtitia; Buronfosse, Thierry; Beisel, Jean-Nicolas; Giambérini, Laure

    2012-01-01

    Biological responses measured in aquatic organisms to monitor environmental pollution could be also affected by different biotic and abiotic factors. Among these environmental factors, parasitism has often been neglected even if infection by parasites is very frequent. In the present field investigation, the parasite infra-communities and zebra mussel biological responses were studied up- and downstream a waste water treatment plant in northeast France. In both sites, mussels were infected by ciliates and/or intracellular bacteria, but prevalence rates and infection intensities were different according to the habitat. Concerning the biological responses differences were observed related to the site quality and the infection status. Parasitism affects both systems but seemed to depend mainly on environmental conditions. The influence of parasites is not constant, but remains important to consider it as a potential confounding factor in ecotoxicological studies. This study also emphasizes the interesting use of integrative indexes to synthesize data set. Highlights: ► Study of potential bias associated with the use of infected zebra mussels in ecotoxicological studies. ► Presence of infected mussels on banks and channels, up- and downstream a waste water treatment plant. ► Parasitism influence on biological responses dependent of mussel population history. ► Integrative index, an interesting tool to synthesize the set of biological data. - Parasitism influence on the host physiology would be strongly dependent on environmental conditions but remains a potential confounding factor in ecotoxicological studies.

  3. Sources, factors, mechanisms and possible solutions to pollutants in marine ecosystems

    International Nuclear Information System (INIS)

    Mostofa, Khan M.G.; Liu, Cong-Qiang; Vione, Davide; Gao, Kunshan; Ogawa, Hiroshi

    2013-01-01

    Algal toxins or red-tide toxins produced during algal blooms are naturally-derived toxic emerging contaminants (ECs) that may kill organisms, including humans, through contaminated fish or seafood. Other ECs produced either naturally or anthropogenically ultimately flow into marine waters. Pharmaceuticals are also an important pollution source, mostly due to overproduction and incorrect disposal. Ship breaking and recycle industries (SBRIs) can also release various pollutants and substantially deteriorate habitats and marine biodiversity. Overfishing is significantly increasing due to the global food crisis, caused by an increasing world population. Organic matter (OM) pollution and global warming (GW) are key factors that exacerbate these challenges (e.g. algal blooms), to which acidification in marine waters should be added as well. Sources, factors, mechanisms and possible remedial measures of these challenges to marine ecosystems are discussed, including their eventual impact on all forms of life including humans. -- Review of sources, factors, mechanisms and possible remedial measures of key pollutants (contaminants, toxins, ship breaking, overfishing) in marine ecosystems

  4. Water conservation for semi-arid rangelands

    International Nuclear Information System (INIS)

    Willis, W.O.

    1983-01-01

    Water deficiency is most often the cause for low forage production on rangelands in semi-arid and arid regions. Water conservation methods have been developed but additional research is needed to develop the best management practices for various climatic regions. Poor management is another major cause of low rangeland production. Better management, including the application of research findings, depends on attitudes, policies, adaptability of findings, resources for implementation and a good understanding of the governing biotic and abiotic factors. (author)

  5. Effect of Environmental Factors on Cyanobacterial Abundance and Cyanotoxins Production in Natural and Drinking Water, Bangladesh.

    Science.gov (United States)

    Affan, Abu; Khomavis, Hisham S; Al-Harbi, Salim Marzoog; Haque, Mahfuzul; Khan, Saleha

    2015-02-01

    Cyanobacterial blooms commonly appear during the summer months in ponds, lakes and reservoirs in Bangladesh. In these areas, fish mortality, odorous water and fish and human skin irritation and eye inflammation have been reported. The influence of physicochemical factors on the occurrence of cyanobacteria and its toxin levels were evaluated in natural and drinking water in Bangladesh. A highly sensitive immunosorbent assay was used to detect microcystins (MCs). Cyanobacteria were found in 22 of 23 samples and the dominant species were Microcystis aeruginosa, followed by Microcystisflosaquae, Anabeana crassa and Aphanizomenon flosaquae. Cyanobacterial abundance varied from 39 to 1315 x 10(3) cells mL(-1) in natural water and 31 to 49 x 10(3) cells mL(-1) in tap water. MC concentrations were 25-82300 pg mL(-1) with the highest value measured in the fish research pond, followed by Ishakha Lake. In tap water, MC concentrations ranged from 30-32 pg mL(-1). The correlation between nitrate-nitrogen (NO3-N) concentration and cyanobacterial cell abundance was R2 = 0.62 while that between cyanobacterial abundance and MC concentration was R2 = 0.98. The increased NO3-N from fish feed, organic manure, poultry and dairy farm waste and fertilizer from agricultural land eutrophicated the water bodies and triggered cyanobacterial bloom formation. The increased amount of cyanobacteria produced MCs, subsequently reducing the water quality.

  6. Designing monitoring programs for chemicals of emerging concern in potable reuse--what to include and what not to include?

    Science.gov (United States)

    Drewes, J E; Anderson, P; Denslow, N; Olivieri, A; Schlenk, D; Snyder, S A; Maruya, K A

    2013-01-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than '1' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound.

  7. Increasing the technical and economic performance of wind diesel systems by including fresh water production

    DEFF Research Database (Denmark)

    Bindner, H.; Lundsager, P.

    1996-01-01

    In many remote regions of the world there is a lack of both electricity and potable water. In order to increase the standard of living and thus maintain the population both power and water have to be supplied at reasonable prices. A good option at many of these places are wind diesel systems...

  8. Untangling Risk in Water Supply Systems: What Factors Drive Long-term Adaptation?

    Science.gov (United States)

    Zeff, H. B.; Lin, L.; Band, L. E.; Reed, P. M.; Characklis, G. W.

    2016-12-01

    Deeply uncertain factors like climate change, the hydrologic impacts of urbanization, forest evolution, and long-term demand forecasts make water supply planning a `wicked' problem. The traditional technique of assessing risk based on historical observations can be inadequate in the face of environmental non-stationarity. However, competing models and limited observational data make it difficult for decision makers and experts to agree on how much uncertainty should be built into analyses of risk, particularly at the timescales relevant to long-term investments in water infrastructure. Further, the physical connectivity of these deeply uncertain processes create inter-related systems, amplifying the challenges of a `worst case scenario'. The development of adaptive systems and planning processes provide solutions that have been shown to meet technical, environmental, and social objectives at lower costs. Instead of developing plans with fixed targets for the timing of actions, adaptive plans develop risk metrics and thresholds that are able to integrate new information to determine when conditions reach a `tipping point' which necessitates action. It is an open question as to how new information can be best integrated into the decision-making process (i.e. how much weight do we give new observations relative to the historical record), but a better understanding of the way the relevant systems are expected to evolve and change over time could inform these decisions. In this study, we use linked, dynamic models of temperature and precipitation changes, forest evolution, urbanization, hydrology, and water demand to develop scenarios for an adaptive water management framework that uses risk-based metrics to make short- and long-term decisions. The impact of individual environmental processes on the adaptive capability of this management framework is evaluated through problem formulations that successively increase the complexity of the uncertainty scenarios. Although

  9. Accepting managed aquifer recharge of urban storm water reuse: The role of policy-related factors

    Science.gov (United States)

    Mankad, Aditi; Walton, Andrea

    2015-12-01

    A between-groups experimental design examined public acceptance for managed aquifer recharge of storm water for indirect potable and nonpotable reuse; acceptance was based on five policy-related variables (fairness, effectiveness, trust, importance of safety assurances, and importance of communication activities). Results showed that public acceptance (N = 408) for managed aquifer recharge of storm water was higher for nonpotable applications, as was the importance of safety assurances. Analyses of variance also showed that perceptions of fairness and effectiveness were higher for a nonpotable scheme, but not trust. A three-step hierarchical regression (Step 1: age, gender, education, and income; Step 2: type of use; Step 3: fairness, effectiveness, trust, safety assurance, and communication activities) demonstrated that type of storm water use and the policy-related factors accounted for 73% of the variance in acceptance of storm water (R2 = 0.74, adjusted R2 = 0.74, F (10, 397) = 113.919, p important predictors were perceptions of trust in water authorities, perceptions of effectiveness, and perceptions of fairness. Interestingly, while safety assurance was important in attitudinal acceptance of managed aquifer recharge based on type of use, safety assurance was not found to be significant predictor of acceptance. This research suggests that policy-makers should look to address matters of greater public importance and drive such as fairness, trust, and effectiveness of storm water programs and advocate these at the forefront of their policies, rather than solely on education campaigns.

  10. Pesticide exposure as risk factor for non-Hodgkin lymphoma including histopathological subgroup analysis.

    Science.gov (United States)

    Eriksson, Mikael; Hardell, Lennart; Carlberg, Michael; Akerman, Måns

    2008-10-01

    We report a population based case-control study of exposure to pesticides as risk factor for non-Hodgkin lymphoma (NHL). Male and female subjects aged 18-74 years living in Sweden were included during December 1, 1999, to April 30, 2002. Controls were selected from the national population registry. Exposure to different agents was assessed by questionnaire. In total 910 (91 %) cases and 1016 (92%) controls participated. Exposure to herbicides gave odds ratio (OR) 1.72, 95% confidence interval (CI) 1.18-2.51. Regarding phenoxyacetic acids highest risk was calculated for MCPA; OR 2.81, 95% CI 1.27-6.22, all these cases had a latency period >10 years. Exposure to glyphosate gave OR 2.02, 95% CI 1.10-3.71 and with >10 years latency period OR 2.26, 95% CI 1.16-4.40. Insecticides overall gave OR 1.28, 95% CI 0.96-1.72 and impregnating agents OR 1.57, 95% CI 1.07-2.30. Results are also presented for different entities of NHL. In conclusion our study confirmed an association between exposure to phenoxyacetic acids and NHL and the association with glyphosate was considerably strengthened.

  11. China's water scarcity.

    Science.gov (United States)

    Jiang, Yong

    2009-08-01

    China has been facing increasingly severe water scarcity, especially in the northern part of the country. China's water scarcity is characterized by insufficient local water resources as well as reduced water quality due to increasing pollution, both of which have caused serious impacts on society and the environment. Three factors contribute to China's water scarcity: uneven spatial distribution of water resources; rapid economic development and urbanization with a large and growing population; and poor water resource management. While it is nearly impossible to adjust the first two factors, improving water resource management represents a cost-effective option that can alleviate China's vulnerability to the issue. Improving water resource management is a long-term task requiring a holistic approach with constant effort. Water right institutions, market-based approaches, and capacity building should be the government's top priority to address the water scarcity issue.

  12. The seat of ground water discharge as ore-mabilizing factor in the formatian of hydrogenic uranium deposits

    International Nuclear Information System (INIS)

    Natal'chenko, B.I.; Gol'dshtejn, R.I.

    1982-01-01

    The role of structural-hydrogeological factor in the process of ore-controlling zoning development during hydrogeneous deposit formation is discussed, as reflecting in the most objective way the spreading of stratal oxidation zones and morphology of uranium mineralization as regards discharge seats because there are only they which mobilize stratal waters for active displacement. The types of discharge seats of stratal waters and their effect on formation of ore-controlling zones of stratal oxidation with uranium mineralization are presented. The conclusion is drawn that local and regional discharge seats of stratal waters dictate both the spacing of regional fronts of stratal-oxidized rocks and their ore content degree. The displacement of discharge seats or their growing into local regions of alimentation results in reorganization of the total ore-controlling zoning, which enables to consider the seats of water discharge as ore-mobilizing structures in the formation of hydrogenic uranium deposits

  13. Water and waste water management Generation Victoria - Latrobe Valley

    Energy Technology Data Exchange (ETDEWEB)

    Longmore, G. [Hazelwood Power Corporation, VIC (Australia); Pacific Power (International) Pty. Ltd., Sydney, NSW (Australia)

    1995-12-31

    Water is a necessary resource for coal fired power plant and waste water is generated. The efficient management of water and waste water systems becomes an important operational environmental factor. This paper describes the development and implementation of a ten year water and waste water management strategy for the Latrobe Valley Group of brown coal fired power stations in Victoria. In early 1991, a team was put together of representatives from each power site to develop the strategy entitled `SECV Latrobe Valley Water and Wastewater Management Strategy`. The strategy was developed with extensive public consultation, which was a factor in protracting the process such that the final document was not promulgated until late 1992. However, the final comprehensive document endorsed and agreed by management, has since attracted favourable comment as a model of its type. (author). 2 figs.

  14. Water and waste water management Generation Victoria - Latrobe Valley

    International Nuclear Information System (INIS)

    Longmore, G.

    1995-01-01

    Water is a necessary resource for coal fired power plant and waste water is generated. The efficient management of water and waste water systems becomes an important operational environmental factor. This paper describes the development and implementation of a ten year water and waste water management strategy for the Latrobe Valley Group of brown coal fired power stations in Victoria. In early 1991, a team was put together of representatives from each power site to develop the strategy entitled 'SECV Latrobe Valley Water and Wastewater Management Strategy'. The strategy was developed with extensive public consultation, which was a factor in protracting the process such that the final document was not promulgated until late 1992. However, the final comprehensive document endorsed and agreed by management, has since attracted favourable comment as a model of its type. (author). 2 figs

  15. Great Lakes water quality initiative technical support document for the procedure to determine bioaccumulation factors. Draft report

    International Nuclear Information System (INIS)

    1993-03-01

    The purpose of the document is to provide the technical information and rationale in support of the proposed procedures to determine bioaccumulation factors. Bioaccumulation factors, together with the quantity of aquatic organisms eaten, determine the extent to which people and wildlife are exposed to chemicals through the consumption of aquatic organisms. The more bioaccumulative a pollutant is, the more important the consumption of aquatic organisms becomes as a potential source of contaminants to humans and wildlife. Bioaccumulation factors are needed to determine both human health and wildlife tier I water quality criteria and tier II values. Also, they are used to define Bioaccumulative Chemicals of Concern among the Great Lakes Initiative universe of pollutants. Bioaccumulation factors range from less than one to several million

  16. Effect of Various Water Chemistry Factors on Legionella Proliferation and the Premise Plumbing Microbiome Composition

    OpenAIRE

    Proctor, Caitlin Rose

    2014-01-01

    Premise plumbing, the pipes and fixtures at the building level, present a unique challenge for maintaining drinking water quality. Of particular concern are opportunistic pathogens, including Legionella pneumophila which can regrow in premise plumbing and cause disease in immunocompromised populations. The goal of this work was to explore engineering methods for control of L. pneumophila and total regrowth. The first line of study involved a series of experiments with simulated glass water he...

  17. Water demand management in times of drought: What matters for water conservation

    Science.gov (United States)

    Maggioni, Elena

    2015-01-01

    Southern California is subject to long droughts and short wet spells. Its water agencies have put in place voluntary, mandatory, and market-based conservation strategies since the 1980s. By analyzing water agencies' data between 2006 and 2010, this research studies whether rebates for water efficient fixtures, water rates, or water ordinances have been effective, and tests whether structural characteristics of water agencies have affected the policy outcome. It finds that mandates to curb outdoor water uses are correlated with reductions in residential per capita water usage, while water rates and subsidies for water saving devices are not. It also confirms that size is a significant policy implementation factor. In a policy perspective, the transition from a water supply to a water demand management-oriented strategy appears guided by mandates and by contextual factors such as the economic cycle and the weather that occur outside the water governance system. Three factors could improve the conservation effort: using prices as a conservation tool, not only as a cost recovering instrument; investing in water efficient tools only when they provide significant water savings; supporting smaller agencies in order to give them opportunities to implement conservation strategies more effectively or to help them consolidate.

  18. Water Quality Drivers in 11 Gulf of Mexico Estuaries

    Directory of Open Access Journals (Sweden)

    Matthew J. McCarthy

    2018-02-01

    Full Text Available Coastal water-quality is both a primary driver and also a consequence of coastal ecosystem health. Turbidity, a measure of dissolved and particulate water-quality matter, is a proxy for water quality, and varies on daily to interannual periods. Turbidity is influenced by a variety of factors, including algal particles, colored dissolved organic matter, and suspended sediments. Identifying which factors drive trends and extreme events in turbidity in an estuary helps environmental managers and decision makers plan for and mitigate against water-quality issues. Efforts to do so on large spatial scales have been hampered due to limitations of turbidity data, including coarse and irregular temporal resolution and poor spatial coverage. We addressed these issues by deriving a proxy for turbidity using ocean color satellite products for 11 Gulf of Mexico estuaries from 2000 to 2014 on weekly, monthly, seasonal, and annual time-steps. Drivers were identified using Akaike’s Information Criterion and multiple regressions to model turbidity against precipitation, wind speed, U and V wind vectors, river discharge, water level, and El Nino Southern Oscillation and North Atlantic Oscillation climate indices. Turbidity variability was best explained by wind speed across estuaries for both time-series and extreme turbidity events, although more dynamic patterns were found between estuaries over various time steps.

  19. Validation for a new apparatus measuring water vapour enhancement factors up to 6 MPa

    International Nuclear Information System (INIS)

    Sairanen, H; Heinonen, M

    2014-01-01

    High accuracy dew-point measurements require a water vapour enhancement factor to correct the effects of pressure drop in a sampling line. The enhancement factor is also needed when a humidity quantity value is converted to another. In this paper a new apparatus for traceable measurements of the enhancement factor is presented along with the results of validation measurements with air and methane. The apparatus is designed for dew-point temperatures from −50 to +15 °C and the pressure range from atmospheric pressure up to 6 MPa. The performance of the apparatus was investigated by comparing measurement results to the literature data for air and the data calculated from published thermodynamic measurement results for methane. It is shown that the experimental results agree with the reference data within the estimated uncertainties. (paper)

  20. Modelling of Water Cooled Fuel Including Design Basis and Severe Accidents. Proceedings of a Technical Meeting

    International Nuclear Information System (INIS)

    2015-11-01

    The demands on nuclear fuel have recently been increasing, and include transient regimes, higher discharge burnup and longer fuel cycles. This has resulted in an increase of loads on fuel and core internals. In order to satisfy these demands while ensuring compliance with safety criteria, new national and international programmes have been launched and advanced modelling codes are being developed. The Fukushima Daiichi accident has particularly demonstrated the need for adequate analysis of all aspects of fuel performance to prevent a failure and also to predict fuel behaviour were an accident to occur.This publication presents the Proceedings of the Technical Meeting on Modelling of Water Cooled Fuel Including Design Basis and Severe Accidents, which was hosted by the Nuclear Power Institute of China (NPIC) in Chengdu, China, following the recommendation made in 2013 at the IAEA Technical Working Group on Fuel Performance and Technology. This recommendation was in agreement with IAEA mid-term initiatives, linked to the post-Fukushima IAEA Nuclear Safety Action Plan, as well as the forthcoming Coordinated Research Project (CRP) on Fuel Modelling in Accident Conditions. At the technical meeting in Chengdu, major areas and physical phenomena, as well as types of code and experiment to be studied and used in the CRP, were discussed. The technical meeting provided a forum for international experts to review the state of the art of code development for modelling fuel performance of nuclear fuel for water cooled reactors with regard to steady state and transient conditions, and for design basis and early phases of severe accidents, including experimental support for code validation. A round table discussion focused on the needs and perspectives on fuel modelling in accident conditions. This meeting was the ninth in a series of IAEA meetings, which reflects Member States’ continuing interest in nuclear fuel issues. The previous meetings were held in 1980 (jointly with

  1. Statistics concerning the Apollo command module water landing, including the probability of occurrence of various impact conditions, sucessful impact, and body X-axis loads

    Science.gov (United States)

    Whitnah, A. M.; Howes, D. B.

    1971-01-01

    Statistical information for the Apollo command module water landings is presented. This information includes the probability of occurrence of various impact conditions, a successful impact, and body X-axis loads of various magnitudes.

  2. Public opinion on water reuse options

    International Nuclear Information System (INIS)

    Bruvold, W.H.

    1988-01-01

    Public policy on waste water reuse options must be informed by public opinion because it is the public who must pay the cost of developing the option and who will be served by the option in the future. For public policy on reuse, guidance for innovative reuse is not as simple as first believed. It seems that public opinion regarding actual community reuse options is affected by the linkage of several factors, including water conservation, health protection, treatment and distribution costs, and environmental enhancement. Probability sampling was used in 7 studies to select respondents who were queried regarding their opinions on various reclaimed water uses such as ranging from cooling tower water to full domestic use. These 7 are briefly reviewed

  3. Factors Influencing Water Resource Governance among Pastoral Community at Mkondoa Sub-Catchment Morogoro Region Tanzania

    Directory of Open Access Journals (Sweden)

    Yeremia Yohana Masifia

    2017-06-01

    Full Text Available The importance of proper Water Resource Management with greater emphasis on ensuring sustainability quality accountability and community participation has become imminent as water resources increasingly become scarce Harvey et al 2007. Water resources management in Tanzania is governed under the National Water Policy of 2002 and Water Resources Management Act No.11 of year 2009. Other related legislations include Environmental Management Act No. 20 of year 2004 Forest Policy and Forest Act No. 14 of year 2002 and Water Supply Act No.12 of year 2009 among others. However the mechanisms processes and institutions through which all stakeholders articulate their priorities exercise their legal rights meet their obligations and mediate their differences is still missing. This study employed descriptive exploratory research design. Data collection was done by the use of both structured and semi structured interview to respondents who were both purpose and simple randomly selected observation and focus group discussion. Review of reports from Districts and Basin offices and internet to access relevant secondary information was done. Results show that WUAs LGAs and WSSAs lack relevant understanding capacities management and law enforcement as result water management generally remains non participatory inefficient and expensive and increased water user conflicts in Kisangata and Ilonga WUAs of Mkondoa sub catchment Morogoro region. The study propose participatory approaches best practices on water resource management at local level for embracement of Community- Based Water Resource Management as the only option of managing sub catchment water resources and reduce water related conflicts among water users. Awareness creation on policy and establishment of alternative economic activities like horticulture bee keeping and poultry is significant to give relief to land.

  4. A Study on the Rate of Events and Water Loss in Water Distribution Network of Azna, Lorstan, Iran during 2008-2014 and Its Associated Factors

    Directory of Open Access Journals (Sweden)

    Mohammad Adeli

    2016-12-01

    Full Text Available Introduction and purpose: One of the problems of water distribution systems is loss of large volumes of water due to the occurrence of various events, which incurs a huge financial loss. Regarding this, the aim of the present study was to investigate the rate of events and water loss in the water distribution system and its related factors in Azna, Lorestan province, Iran, during 2008-2014. Methods: This cross-sectional study was conducted using census method, surveys, and field data collection. The amount of water production and consumption, the volumes of water loss, the number of accidents, type of pipe, pressure zone, as well as the age and length of the pipes recorded during 2008- 2014 were studied and analyzed. Results: According to the results, the highest (34.48% and lowest (20.57% amount of water losses happened in 2008 and 2014, respectively. High pressures in water systems had significant relationship with the number of events as well as the amount of water loss and water consumption. In addition, higher length and age of the pipes had a direct correlation with increased number of events and water loss. Furthermore, the maximum number of events were found to occur in the pipe embranchment and galvanized pipes. Conclusion: This study showed that of events was directly related to the length and age of the pipes, the water pressure, and number of branches. Also water loss quantity can be reduced by applying suitable management techniques in different sections. Furthermore, the water loss can be significantly controlled by taking such measures as reducing the pressure in the high-pressure zones, timely replacement of old and inappropriate pipes, appropriate fixing of the pipes, replacement of the galvanized pipe, and standard implementation of pipes and fittings.

  5. Surface water quality in streams and rivers: introduction, scaling, and climate change: Chapter 5

    Science.gov (United States)

    Loperfido, John

    2013-01-01

    A variety of competing and complementary needs such as ecological health, human consumption, transportation, recreation, and economic value make management and protection of water resources in riverine environments essential. Thus, an understanding of the complex and interacting factors that dictate riverine water quality is essential in empowering stake-holders to make informed management decisions (see Chapter 1.15 for additional information on water resource management). Driven by natural and anthropogenic forcing factors, a variety of chemical, physical, and biological processes dictate riverine water quality, resulting in temporal and spatial patterns and cycling (see Chapter 1.2 for information describing how global change interacts with water resources). Furthermore, changes in climatic forcing factors may lead to long-term deviations in water quality outside the envelope of historical data. The goal of this chapter is to present fundamental concepts dictating the conditions of basic water quality parameters in rivers and streams (herein generally referred to as rivers unless discussing a specific system) in the context of temporal (diel (24 h) to decadal) longitudinal scaling. Understanding water quality scaling in rivers is imperative as water is continually reused and recycled (see also Chapters 3.1 and 3.15); upstream discharges from anthropogenic sources are incorporated into bulk riverine water quality that is used by downstream consumers. Water quality parameters reviewed here include temperature, pH, dissolved oxygen (DO), and suspended sediment and were selected given the abundance of data available for these parameters due to recent advances in water quality sensor technology (see Chapter 4.13 for use of hydrologic data in watershed management). General equations describing reactions affecting water temperature, pH, DO, and suspended sediment are included to convey the complexity of how simultaneously occurring reactions can affect water quality

  6. Environmental factor approach to account for water effects in pressure vessel and piping fatigue evaluations

    International Nuclear Information System (INIS)

    Mehta, H.S.; Gosselin, S.R.

    1998-01-01

    This paper summarizes past and current studies of the environmental fatigue effects in light water reactor (LWR) applications. Current Argonne and Japanese research efforts are reviewed and an approach to calculate an environmental correction factor is described. A description of how the proposed approach can be implemented in section III, NB-3600 and NB-3200-type fatigue evaluations is presented along with examples of applying the approach to piping (NB-3600) and safe end fatigue evaluations. These procedures were applied to several BWR and pressurized water reactor (PWR) example cases. The results of these case studies indicated that there is a modest increase in calculated fatigue usage, which is considerably less than the results obtained when the NUREG/CR-5999 curves are applied directly. (orig.)

  7. Numerical simulation of water and sand blowouts when penetrating through shallow water flow formations in deep water drilling

    Science.gov (United States)

    Ren, Shaoran; Liu, Yanmin; Gong, Zhiwu; Yuan, Yujie; Yu, Lu; Wang, Yanyong; Xu, Yan; Deng, Junyu

    2018-02-01

    In this study, we applied a two-phase flow model to simulate water and sand blowout processes when penetrating shallow water flow (SWF) formations during deepwater drilling. We define `sand' as a pseudo-component with high density and viscosity, which can begin to flow with water when a critical pressure difference is attained. We calculated the water and sand blowout rates and analyzed the influencing factors from them, including overpressure of the SWF formation, as well as its zone size, porosity and permeability, and drilling speed (penetration rate). The obtained data can be used for the quantitative assessment of the potential severity of SWF hazards. The results indicate that overpressure of the SWF formation and its zone size have significant effects on SWF blowout. A 10% increase in the SWF formation overpressure can result in a more than 90% increase in the cumulative water blowout and a 150% increase in the sand blowout when a typical SWF sediment is drilled. Along with the conventional methods of well flow and pressure control, chemical plugging, and the application of multi-layer casing, water and sand blowouts can be effectively reduced by increasing the penetration rate. As such, increasing the penetration rate can be a useful measure for controlling SWF hazards during deepwater drilling.

  8. Factors Stimulating Propagation of Legionellae in Cooling Tower Water

    OpenAIRE

    Yamamoto, Hiroyuki; Sugiura, Minoru; Kusunoki, Shinji; Ezaki, Takayuki; Ikedo, Masanari; Yabuuchi, Eiko

    1992-01-01

    Our survey of cooling tower water demonstrated that the highest density of legionellae, ≥104 CFU/100 ml, appeared in water containing protozoa, ≥102 MPN/100 ml, and heterotrophic bacteria, ≥106 CFU/100 ml, at water temperatures between 25 and 35°C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 105 CFU/100 ml, occurs in summer. The counts of legionellae correlated positively with increases in water temperature, pH, and protozoan counts, but not w...

  9. Transboundary Water: Improving Methodologies and Developing Integrated Tools to Support Water Security

    Science.gov (United States)

    Hakimdavar, Raha; Wood, Danielle; Eylander, John; Peters-Lidard, Christa; Smith, Jane; Doorn, Brad; Green, David; Hummel, Corey; Moore, Thomas C.

    2018-01-01

    River basins for which transboundary coordination and governance is a factor are of concern to US national security, yet there is often a lack of sufficient data-driven information available at the needed time horizons to inform transboundary water decision-making for the intelligence, defense, and foreign policy communities. To address this need, a two-day workshop entitled Transboundary Water: Improving Methodologies and Developing Integrated Tools to Support Global Water Security was held in August 2017 in Maryland. The committee that organized and convened the workshop (the Organizing Committee) included representatives from the National Aeronautics and Space Administration (NASA), the US Army Corps of Engineers Engineer Research and Development Center (ERDC), and the US Air Force. The primary goal of the workshop was to advance knowledge on the current US Government and partners' technical information needs and gaps to support national security interests in relation to transboundary water. The workshop also aimed to identify avenues for greater communication and collaboration among the scientific, intelligence, defense, and foreign policy communities. The discussion around transboundary water was considered in the context of the greater global water challenges facing US national security.

  10. Designing monitoring programs for chemicals of emerging concern in potable reuse ⋯ What to include and what not to include?

    KAUST Repository

    Drewes, Jorg; Anderson, Paul D.; Denslow, Nancy D.; Olivieri, Adam W.; Schlenk, Daniel K.; Snyder, Shane A.; Maruya, Keith

    2012-01-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than '1' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound. © IWA Publishing 2013.

  11. Designing monitoring programs for chemicals of emerging concern in potable reuse ⋯ What to include and what not to include?

    KAUST Repository

    Drewes, Jorg

    2012-11-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than \\'1\\' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound. © IWA Publishing 2013.

  12. Water equivalence of some plastic-water phantom materials for clinical proton beam dosimetry

    International Nuclear Information System (INIS)

    Al-Sulaiti, L.; Shipley, D.; Thomas, R.; Owen, P.; Kacperek, A.; Regan, P.H.; Palmans, H.

    2012-01-01

    Plastic-water phantom materials are not exactly water equivalent since they have a different elemental composition and different interaction cross sections for protons than water. Several studies of the water equivalence of plastic-water phantom materials have been reported for photon and electron beams, but none for clinical proton beams. In proton beams, the difference between non-elastic nuclear interactions in plastic-water phantom materials compared to those in water should be considered. In this work, the water equivalence of Plastic Water ® (PW) 1 , Plastic Water ® Diagnostic Therapy (PWDT) 1 and solid water (WT1) 2 phantoms was studied for clinical proton energies of 60 MeV and 200 MeV. This was done by evaluating the fluence correction factor at equivalent depths; first with respect to water and then with respect to graphite by experiment and Monte Carlo (MC) simulations using FLUKA. MC simulations showed that the fluence correction with respect to water was less than 0.5% up to the entire penetration depth of the protons at 60 MeV and less than 1% at 200 MeV up to 20 cm depth for PWDT, PW and WT1. With respect to graphite the fluence correction was about 0.5% for 60 MeV and about 4% for 200 MeV. The experimental results for modulated and un-modulated 60 MeV proton beams showed good agreement with the MC simulated fluence correction factors with respect to graphite deviating less than 1% from unity for the three plastic-water phantoms. - Highlights: ► We study plastic-water in clinical proton beams by experiment and Monte Carlo. ► We obtain fluence correction factors for water and graphite. ► The correction factor for water was close to 1 at 60 MeV and <0.990 at 200 MeV. ► The correction factor for graphite was ∼0.5% at 60 MeV and up to 4% at 200 MeV.

  13. Spatial Variability of Metals in Surface Water and Sediment in the Langat River and Geochemical Factors That Influence Their Water-Sediment Interactions

    Directory of Open Access Journals (Sweden)

    Wan Ying Lim

    2012-01-01

    Full Text Available This paper determines the controlling factors that influence the metals’ behavior water-sediment interaction facies and distribution of elemental content (75As, 111Cd, 59Co, 52Cr, 60Ni, and 208Pb in water and sediment samples in order to assess the metal pollution status in the Langat River. A total of 90 water and sediment samples were collected simultaneously in triplicate at 30 sampling stations. Selected metals were analyzed using ICP-MS, and the metals’ concentration varied among stations. Metal concentrations of water ranged between 0.08–24.71 μg/L for As, <0.01–0.53 μg/L for Cd, 0.06–6.22 μg/L for Co, 0.32–4.67 μg/L for Cr, 0.80–24.72 μg/L for Ni, and <0.005–6.99 μg/L for Pb. Meanwhile, for sediment, it ranged between 4.47–30.04 mg/kg for As, 0.02–0.18 mg/kg for Cd, 0.87–4.66 mg/kg for Co, 4.31–29.04 mg/kg for Cr, 2.33–8.25 mg/kg for Ni and 5.57–55.71 mg/kg for Pb. The average concentration of studied metals in the water was lower than the Malaysian National Standard for Drinking Water Quality proposed by the Ministry of Health. The average concentration for As in sediment was exceeding ISQG standards as proposed by the Canadian Sediment Quality Guidelines. Statistical analyses revealed that certain metals (As, Co, Ni, and Pb were generally influenced by pH and conductivity. These results are important when making crucial decisions in determining potential hazardous levels of these metals toward humans.

  14. A membrane-based subsystem for very high recoveries of spacecraft waste waters

    Science.gov (United States)

    Ray, Roderick J.; Retzlaff, Sandra E.; Radke-Mitchell, Lyn; Newbold, David D.; Price, Donald F.

    1986-01-01

    This paper describes the continued development of a membrane-based subsystem designed to recover up to 99.5 percent of the water from various spacecraft waste waters. Specifically discussed are: (1) the design and fabrication of an energy-efficient reverse-osmosis (RO) breadboard subsystem; (2) data showing the performance of this subsystem when operated on a synthetic wash-water solution - including the results of a 92-day test; and (3) the results of pasteurization studies, including the design and operation of an in-line pasteurizer. Also included in this paper is a discussion of the design and performance of a second RO stage. This second stage results in higher-purity product water at a minimal energy requirement and provides a substantial redundancy factor to this subsystem.

  15. Water quality index for Al-Gharraf River, southern Iraq

    Directory of Open Access Journals (Sweden)

    Salam Hussein Ewaid

    2017-06-01

    Full Text Available The Water Quality Index has been developed mathematically to evaluate the water quality of Al-Gharraf River, the main branch of the Tigris River in the south of Iraq. Water samples were collected monthly from five sampling stations during 2015–2016, and 11 parameters were analyzed: biological oxygen demand, total dissolved solids, the concentration of hydrogen ions, dissolved oxygen, turbidity, phosphates, nitrates, chlorides, as well as turbidity, total hardness, electrical conductivity and alkalinity. The index classified the river water, without including turbidity as a parameter, as good for drinking at the first station, poor at stations 2, 3, 4 and very poor at station 5. When turbidity was included, the index classified the river water as unsuitable for drinking purposes in the entire river. The study highlights the importance of applying the water quality indices which indicate the total effect of the ecological factors on surface water quality and which give a simple interpretation of the monitoring data to help local people in improving water quality.

  16. Comparative Assessment of Physical and Social Determinants of Water Quantity and Water Quality Concerns

    Science.gov (United States)

    Gunda, T.; Hornberger, G. M.

    2017-12-01

    Concerns over water resources have evolved over time, from physical availability to economic access and recently, to a more comprehensive study of "water security," which is inherently interdisciplinary because a secure water system is influenced by and affects both physical and social components. The concept of water security carries connotations of both an adequate supply of water as well as water that meets certain quality standards. Although the term "water security" has many interpretations in the literature, the research field has not yet developed a synthetic analysis of water security as both a quantity (availability) and quality (contamination) issue. Using qualitative comparative and multi-regression analyses, we evaluate the primary physical and social factors influencing U.S. states' water security from a quantity perspective and from a quality perspective. Water system characteristics are collated from academic and government sources and include access/use, governance, and sociodemographic, and ecosystem metrics. Our analysis indicates differences in variables driving availability and contamination concerns; for example, climate is a more significant determinant in water quantity-based security analyses than in water quality-based security analyses. We will also discuss coevolution of system traits and the merits of constructing a robust water security index based on the relative importance of metrics from our analyses. These insights will improve understanding of the complex interactions between quantity and quality aspects and thus, overall security of water systems.

  17. Managing water pressure for water savings in developing countries

    African Journals Online (AJOL)

    2014-03-03

    Mar 3, 2014 ... effort into providing customers with a reliable level of service, often via poor water ... budgets. There are many factors contributing to water losses in water .... given relationship does not reflect the impact of pressure on.

  18. A Novel Water Supply Network Sectorization Methodology Based on a Complete Economic Analysis, Including Uncertainties

    Directory of Open Access Journals (Sweden)

    Enrique Campbell

    2016-04-01

    Full Text Available The core idea behind sectorization of Water Supply Networks (WSNs is to establish areas partially isolated from the rest of the network to improve operational control. Besides the benefits associated with sectorization, some drawbacks must be taken into consideration by water operators: the economic investment associated with both boundary valves and flowmeters and the reduction of both pressure and system resilience. The target of sectorization is to properly balance these negative and positive aspects. Sectorization methodologies addressing the economic aspects mainly consider costs of valves and flowmeters and of energy, and the benefits in terms of water saving linked to pressure reduction. However, sectorization entails other benefits, such as the reduction of domestic consumption, the reduction of burst frequency and the enhanced capacity to detect and intervene over future leakage events. We implement a development proposed by the International Water Association (IWA to estimate the aforementioned benefits. Such a development is integrated in a novel sectorization methodology based on a social network community detection algorithm, combined with a genetic algorithm optimization method and Monte Carlo simulation. The methodology is implemented over a fraction of the WSN of Managua city, capital of Nicaragua, generating a net benefit of 25,572 $/year.

  19. Factors influencing arsenic and nitrate removal from drinking water in a continuous flow electrocoagulation (EC) process

    International Nuclear Information System (INIS)

    Kumar, N. Sanjeev; Goel, Sudha

    2010-01-01

    An experimental study was conducted under continuous flow conditions to evaluate some of the factors influencing contaminant removal by electrocoagulation (EC). A bench-scale simulation of drinking water treatment was done by adding a filtration column after a rectangular EC reactor. Contaminant removal efficiency was determined for voltages ranging from 10 to 25 V and a comparative study was done with distilled water and tap water for two contaminants: nitrate and arsenic(V). Maximum removal efficiency was 84% for nitrate at 25 V and 75% for arsenic(V) at 20 V. No significant difference in contaminant removal was observed in tap water versus distilled water. Increase in initial As(V) concentration from 1 ppm to 2 ppm resulted in a 10% increase in removal efficiency. Turbidity in the EC reactor effluent was 52 NTU and had to be filtered to achieve acceptable levels of final turbidity (5 NTU) at steady-state. The flow regime in the continuous flow reactor was also evaluated in a tracer study to determine whether it is a plug flow reactor (PFR) or constantly stirred tank reactor (CSTR) and the results show that this reactor was close to an ideal CSTR, i.e., it was fairly well-mixed.

  20. Factors influencing arsenic and nitrate removal from drinking water in a continuous flow electrocoagulation (EC) process

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, N. Sanjeev [Civil Engineering Department, IIT Kharagpur, Kharagpur 721302 (India); Goel, Sudha, E-mail: sudhagoel@civil.iitkgp.ernet.in [Civil Engineering Department, IIT Kharagpur, Kharagpur 721302 (India)

    2010-01-15

    An experimental study was conducted under continuous flow conditions to evaluate some of the factors influencing contaminant removal by electrocoagulation (EC). A bench-scale simulation of drinking water treatment was done by adding a filtration column after a rectangular EC reactor. Contaminant removal efficiency was determined for voltages ranging from 10 to 25 V and a comparative study was done with distilled water and tap water for two contaminants: nitrate and arsenic(V). Maximum removal efficiency was 84% for nitrate at 25 V and 75% for arsenic(V) at 20 V. No significant difference in contaminant removal was observed in tap water versus distilled water. Increase in initial As(V) concentration from 1 ppm to 2 ppm resulted in a 10% increase in removal efficiency. Turbidity in the EC reactor effluent was 52 NTU and had to be filtered to achieve acceptable levels of final turbidity (5 NTU) at steady-state. The flow regime in the continuous flow reactor was also evaluated in a tracer study to determine whether it is a plug flow reactor (PFR) or constantly stirred tank reactor (CSTR) and the results show that this reactor was close to an ideal CSTR, i.e., it was fairly well-mixed.

  1. Factors affecting radon removal from Rn-222 enriched water

    International Nuclear Information System (INIS)

    Abulfaraj, W.H.; Mamoon, A.

    1994-01-01

    Continued use of potable well water that has elevated levels of Rn-222 is harmful to human health. activated carbon, aeration and heating can remove radon from treated water. Water artificially enriched with Rn-222 using a pitchblende source was studied in a laboratory scale model under controlled conditions. (author), 3 figs., 3 refs

  2. Water quality and health in northern Canada: stored drinking water and acute gastrointestinal illness in Labrador Inuit.

    Science.gov (United States)

    Wright, Carlee J; Sargeant, Jan M; Edge, Victoria L; Ford, James D; Farahbakhsh, Khosrow; Shiwak, Inez; Flowers, Charlie; Harper, Sherilee L

    2017-07-12

    One of the highest self-reported incidence rates of acute gastrointestinal illness (AGI) in the global peer-reviewed literature occurs in Inuit communities in the Canadian Arctic. This high incidence of illness could be due, in part, to the consumption of contaminated water, as many northern communities face challenges related to the quality of municipal drinking water. Furthermore, many Inuit store drinking water in containers in the home, which could increase the risk of contamination between source and point-of-use (i.e., water recontamination during storage). To examine this risk, this research characterized drinking water collection and storage practices, identified potential risk factors for water contamination between source and point-of-use, and examined possible associations between drinking water contamination and self-reported AGI in the Inuit community of Rigolet, Canada. The study included a cross-sectional census survey that captured data on types of drinking water used, household practices related to drinking water (e.g., how it was collected and stored), physical characteristics of water storage containers, and self-reported AGI. Additionally, water samples were collected from all identified drinking water containers in homes and analyzed for presence of Escherichia coli and total coliforms. Despite municipally treated tap water being available in all homes, 77.6% of households had alternative sources of drinking water stored in containers, and of these containers, 25.2% tested positive for total coliforms. The use of transfer devices and water dippers (i.e., smaller bowls or measuring cups) for the collection and retrieval of water from containers were both significantly associated with increased odds of total coliform presence in stored water (OR transfer device  = 3.4, 95% CI 1.2-11.7; OR dipper  = 13.4, 95% CI 3.8-47.1). Twenty-eight-day period prevalence of self-reported AGI during the month before the survey was 17.2% (95% CI 13

  3. Using the Theory of Planned Behavior to Encourage Water Conservation among Extension Clients

    Science.gov (United States)

    Kumar Chaudhary, Anil; Warner, Laura A.; Lamm, Alexa J.; Israel, Glenn D.; Rumble, Joy N.; Cantrell, Randall A.

    2017-01-01

    Extension professionals can play a role in addressing water scarcity issues by helping home landscape irrigation users to conserve water. This study used survey research to examine the relationship between several variables, including attitudes, subjective norms, perceived behavioral control, personal norms, demographic factors, and past…

  4. [Study on the optimization of monitoring indicators of drinking water quality during health supervision].

    Science.gov (United States)

    Ye, Bixiong; E, Xueli; Zhang, Lan

    2015-01-01

    To optimize non-regular drinking water quality indices (except Giardia and Cryptosporidium) of urban drinking water. Several methods including drinking water quality exceed the standard, the risk of exceeding standard, the frequency of detecting concentrations below the detection limit, water quality comprehensive index evaluation method, and attribute reduction algorithm of rough set theory were applied, redundancy factor of water quality indicators were eliminated, control factors that play a leading role in drinking water safety were found. Optimization results showed in 62 unconventional water quality monitoring indicators of urban drinking water, 42 water quality indicators could be optimized reduction by comprehensively evaluation combined with attribute reduction of rough set. Optimization of the water quality monitoring indicators and reduction of monitoring indicators and monitoring frequency could ensure the safety of drinking water quality while lowering monitoring costs and reducing monitoring pressure of the sanitation supervision departments.

  5. Plutonium in Southern Hemisphere Ocean Waters

    Energy Technology Data Exchange (ETDEWEB)

    Hirose, K. [Sophia University, Tokyo (Japan); Aoyama, M. [Meteorological Research Institute, Tsukuba (Japan); Gastaud, J.; Levy, I. [Marine Environment Laboratories, International Atomic Energy Agency (Monaco); Fukasawa, M. [Japan Agency for Marine-Earth Science and Technology Yokosuka (Japan); Kim, C. -S. [Environment Laboratories, International Atomic Energy Agency, Seibersdorf (Austria); Povinec, P. P. [Comenius University, Bratislava (Slovakia); Roos, P. [Riso National Laboratory, Roskilde (Denmark); Sanchez-Cabeza, J. A. [Universitat Autonoma de Barcelona, Bellaterra (Spain); Yim, S. A. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-07-15

    Plutonium in seawater collected by the BEAGLE2003 cruise was determined using ICP-SF-MS and alpha spectrometry after Fe co-precipitation and radiochemical purification. Levels and distributions of dissolved plutonium activity concentrations in Southern Hemisphere ocean waters are summarized here, including historical data. Pu-239 concentrations in surface water of the central South Pacific (32.5{sup o}S) in 2003 were around 1 mBq/m{sup 3}. The {sup 239}Pu concentrations in the Indian Ocean surface waters (20{sup o}S) were similar to that in the South Pacific, whereas the {sup 239}Pu concentrations in the South Atlantic surface waters (30{sup o}S) were markedly lower than those in the South Pacific and Indian Oceans. The {sup 239}Pu vertical profile pattern was similar to that in the North Pacific subtropical gyre, although {sup 239}Pu concentrations in the deep South Pacific were significantly lower than those in the North Pacific. One of the dominant factors controlling plutonium distributions in the Southern Hemisphere oceans is biogeochemical processes including particle scavenging. (author)

  6. Numerical Calculation of the Peaking Factor of a Water-Cooled W/Cu Monoblock for a Divertor

    Science.gov (United States)

    Han, Le; Chang, Haiping; Zhang, Jingyang; Xu, Tiejun

    2015-09-01

    In order to accurately predict the incident critical heat flux (ICHF, the heat flux at the heated surface when CHF occurs) of a water-cooled W/Cu monoblock for a divertor, the exact knowledge of its peaking factors (fp) under one-sided heating conditions with different design parameters is a key issue. In this paper, the heat conduction in the solid domain of a water-cooled W/Cu monoblock is calculated numerically by assuming the local heat transfer coefficients (HTC) of the cooling wall to be functions of the local wall temperature, so as to obtain fp. The reliability of the calculation method is validated by an experimental example result, with the maximum error of 2.1% only. The effects of geometric and flow parameters on the fp of a water-cooled W/Cu monoblock are investigated. Within the scope of this study, it is shown that the fp increases with increasing dimensionless W/Cu monoblock width and armour thickness (the shortest distance between the heated surface and Cu layer), and the maximum increases are 43.8% and 22.4% respectively. The dimensionless W/Cu monoblock height and Cu thickness have little effect on fp. The increase of Reynolds number and Jakob number causes the increase of fp, and the maximum increases are 6.8% and 9.6% respectively. Based on the calculated results, an empirical correlation on peaking factor is obtained via regression. These results provide a valuable reference for the thermal-hydraulic design of water-cooled divertors. supported by National Magnetic Confinement Fusion Science Program of China (No. 2010GB104005) and Funding of Jiangsu Innovation Program for Graduate Education, China (CXLX12_0170), the Fundamental Research Funds for the Central Universities of China

  7. Effects of natural mineral-rich water consumption on the expression of sirtuin 1 and angiogenic factors in the erectile tissue of rats with fructose-induced metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Cidália D Pereira

    2014-08-01

    Full Text Available Consuming a high-fructose diet induces metabolic syndrome (MS-like features, including endothelial dysfunction. Erectile dysfunction is an early manifestation of endothelial dysfunction and systemic vascular disease. Because mineral deficiency intensifies the deleterious effects of fructose consumption and mineral ingestion is protective against MS, we aimed to characterize the effects of 8 weeks of natural mineral-rich water consumption on the structural organization and expression of vascular growth factors and receptors on the corpus cavernosum (CC in 10% fructose-fed Sprague-Dawley rats (FRUCT. Differences were not observed in the organization of the CC either on the expression of vascular endothelial growth factor (VEGF or the components of the angiopoietins/Tie2 system. However, opposing expression patterns were observed for VEGF receptors (an increase and a decrease for VEGFR1 and VEGFR2, respectively in FRUCT animals, with these patterns being strengthened by mineral-rich water ingestion. Mineral-rich water ingestion (FRUCTMIN increased the proportion of smooth muscle cells compared with FRUCT rats and induced an upregulatory tendency of sirtuin 1 expression compared with the control and FRUCT groups. Western blot results were consistent with the dual immunofluorescence evaluation. Plasma oxidized low-density lipoprotein and plasma testosterone levels were similar among the experimental groups, although a tendency for an increase in the former was observed in the FRUCTMIN group. The mineral-rich water-treated rats presented changes similar to those observed in rats treated with MS-protective polyphenol-rich beverages or subjected to energy restriction, which led us to hypothesize that the effects of mineral-rich water consumption may be more vast than those directly observed in this study.

  8. Source Water Assessment for the Las Vegas Valley Surface Waters

    Science.gov (United States)

    Albuquerque, S. P.; Piechota, T. C.

    2003-12-01

    The 1996 amendment to the Safe Drinking Water Act of 1974 created the Source Water Assessment Program (SWAP) with an objective to evaluate potential sources of contamination to drinking water intakes. The development of a Source Water Assessment Plan for Las Vegas Valley surface water runoff into Lake Mead is important since it will guide future work on source water protection of the main source of water. The first step was the identification of the watershed boundary and source water protection area. Two protection zones were delineated. Zone A extends 500 ft around water bodies, and Zone B extends 3000 ft from the boundaries of Zone A. These Zones extend upstream to the limits of dry weather flows in the storm channels within the Las Vegas Valley. After the protection areas were identified, the potential sources of contamination in the protection area were inventoried. Field work was conducted to identify possible sources of contamination. A GIS coverage obtained from local data sources was used to identify the septic tank locations. Finally, the National Pollutant Discharge Elimination System (NPDES) Permits were obtained from the State of Nevada, and included in the inventory. After the inventory was completed, a level of risk was assigned to each potential contaminating activity (PCA). The contaminants of concern were grouped into five categories: volatile organic compounds (VOCs), synthetic organic compounds (SOCs), inorganic compounds (IOCs), microbiological, and radionuclides. The vulnerability of the water intake to each of the PCAs was assigned based on these five categories, and also on three other factors: the physical barrier effectiveness, the risk potential, and the time of travel. The vulnerability analysis shows that the PCAs with the highest vulnerability rating include septic systems, golf courses/parks, storm channels, gas stations, auto repair shops, construction, and the wastewater treatment plant discharges. Based on the current water quality

  9. Physicochemical and biological factors controlling water column metabolism in Sundarbans estuary, India.

    Science.gov (United States)

    Chaudhuri, Kaberi; Manna, Suman; Sarma, Kakoli Sen; Naskar, Pankaj; Bhattacharyya, Somenath; Bhattacharyya, Maitree

    2012-10-19

    Sundarbans is the single largest deltaic mangrove forest in the world, formed at estuarine phase of the Ganges - Brahmaputra river system. Primary productivity of marine and coastal phytoplankton contributes to 15% of global oceanic production. But unfortunately estuarine dynamics of tropical and subtropical estuaries have not yet received proper attention in spite of the fact that they experience considerable anthropogenic interventions and a baseline data is required for any future comparison. This study is an endeavor to this end to estimate the primary productivity (gross and net), community respiration and nitrification rates in different rivers and tidal creeks around Jharkhali island, a part of Sundarbans estuary surrounded by the mangrove forest during a period of three years starting from November'08 to October'11. Various physical and chemical parameters of water column like pH, temperature, conductivity, dissolved oxygen, turbidity, suspended particulate matter, secchi disc index, tidal fluctuation and tidal current velocity, standing crop and nutrients were measured along with water column productivity. Relationship of net water column productivity with algal biomass (standing crop), nutrient loading and turbidity were determined experimentally. Correlations of bacterial abundance with community respiration and nitrification rates were also explored. Annual integrated phytoplankton production rate of this tidal estuary was estimated to be 151.07 gC m-2 y-1. Gross primary productivity showed marked inter annual variation being lowest in monsoon and highest in postmonsoon period. Average primary production was a function of nutrient loading and light penetration in the water column. High aquatic turbidity, conductivity and suspended particulate matter were the limiting factors to attenuate light penetration with negative influence on primary production. Community respiration and nitrification rates of the estuary were influenced by the bacterial abundance

  10. Physicochemical and biological factors controlling water column metabolism in Sundarbans estuary, India

    Science.gov (United States)

    2012-01-01

    Background Sundarbans is the single largest deltaic mangrove forest in the world, formed at estuarine phase of the Ganges - Brahmaputra river system. Primary productivity of marine and coastal phytoplankton contributes to 15% of global oceanic production. But unfortunately estuarine dynamics of tropical and subtropical estuaries have not yet received proper attention in spite of the fact that they experience considerable anthropogenic interventions and a baseline data is required for any future comparison. This study is an endeavor to this end to estimate the primary productivity (gross and net), community respiration and nitrification rates in different rivers and tidal creeks around Jharkhali island, a part of Sundarbans estuary surrounded by the mangrove forest during a period of three years starting from November’08 to October’11. Results Various physical and chemical parameters of water column like pH, temperature, conductivity, dissolved oxygen, turbidity, suspended particulate matter, secchi disc index, tidal fluctuation and tidal current velocity, standing crop and nutrients were measured along with water column productivity. Relationship of net water column productivity with algal biomass (standing crop), nutrient loading and turbidity were determined experimentally. Correlations of bacterial abundance with community respiration and nitrification rates were also explored. Annual integrated phytoplankton production rate of this tidal estuary was estimated to be 151.07 gC m-2 y-1. Gross primary productivity showed marked inter annual variation being lowest in monsoon and highest in postmonsoon period. Conclusion Average primary production was a function of nutrient loading and light penetration in the water column. High aquatic turbidity, conductivity and suspended particulate matter were the limiting factors to attenuate light penetration with negative influence on primary production. Community respiration and nitrification rates of the estuary were

  11. Potential Impacts of Food Production on Freshwater Availability Considering Water Sources

    Directory of Open Access Journals (Sweden)

    Shinjiro Yano

    2016-04-01

    Full Text Available We quantify the potential impacts of global food production on freshwater availability (water scarcity footprint; WSF by applying the water unavailability factor (fwua as a characterization factor and a global water resource model based on life cycle impact assessment (LCIA. Each water source, including rainfall, surface water, and groundwater, has a distinct fwua that is estimated based on the renewability rate of each geographical water cycle. The aggregated consumptive water use level for food production (water footprint inventory; WI was found to be 4344 km3/year, and the calculated global total WSF was 18,031 km3 H2Oeq/year, when considering the difference in water sources. According to the fwua concept, which is based on the land area required to obtain a unit volume of water from each source, the calculated annual impact can also be represented as 98.5 × 106 km2. This value implies that current agricultural activities requires a land area that is over six times larger than global total cropland. We also present the net import of the WI and WSF, highlighting the importance of quantitative assessments for utilizing global water resources to achieve sustainable water use globally.

  12. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000-2011.

    Science.gov (United States)

    Tuyet-Hanh, Tran Thi; Lee, Jong-Koo; Oh, Juhwan; Van Minh, Hoang; Ou Lee, Chul; Hoan, Le Thi; Nam, You-Seon; Long, Tran Khanh

    2016-01-01

    Despite progress made by the Millennium Development Goal (MDG) number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011) describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9-2.5) to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8-60.0). More efforts are required to increase household access to

  13. Water and Wastewater Rate Hikes Outpace CPI

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, Hannah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fuchs, Heidi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chen, Yuting [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dunham, Camilla [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Williams, Alison [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-31

    Water and wastewater treatment and delivery is the most capital-intensive of all utility services. Historically underpriced, water and wastewater rates have exhibited unprecedented growth in the past fifteen years. Steep annual increases in water and wastewater rates that outpace the Consumer Price Index (CPI) have increasingly become the norm across the United States. In this paper, we analyze water and wastewater rates across U.S. census regions between 2000 and 2014. We also examine some of the driving factors behind these rate increases, including drought, water source, required infrastructure investment, population patterns, and conservation effects. Our results demonstrate that water and wastewater prices have consistently increased and have outstripped CPI throughout the study period nationwide, as well as within each census region. Further, evaluation of the current and upcoming challenges facing water and wastewater utilities suggests that sharp rate increases are likely to continue in the foreseeable future.

  14. Potential microbial risk factors related to soil amendments and irrigation water of potato crops.

    Science.gov (United States)

    Selma, M V; Allende, A; López-Gálvez, F; Elizaquível, P; Aznar, R; Gil, M I

    2007-12-01

    This study assesses the potential microbial risk factors related to the use of soil amendments and irrigation water on potato crops, cultivated in one traditional and two intensive farms during two harvest seasons. The natural microbiota and potentially pathogenic micro-organisms were evaluated in the soil amendment, irrigation water, soil and produce. Uncomposted amendments and residual and creek water samples showed the highest microbial counts. The microbial load of potatoes harvested in spring was similar among the tested farms despite the diverse microbial levels of Listeria spp. and faecal coliforms in the potential risk sources. However, differences in total coliform load of potato were found between farms cultivated in the autumn. Immunochromatographic rapid tests and the BAM's reference method (Bacteriological Analytical Manual; AOAC International) were used to detect Escherichia coli O157:H7 from the potential risk sources and produce. Confirmation of the positive results by polymerase chain reaction procedures showed that the immunochromatographic assay was not reliable as it led to false-positive results. The potentially pathogenic micro-organisms of soil amendment, irrigation water and soil samples changed with the harvest seasons and the use of different agricultural practices. However, the microbial load of the produce was not always influenced by these risk sources. Improvements in environmental sample preparation are needed to avoid interferences in the use of immunochromatographic rapid tests. The potential microbial risk sources of fresh produce should be regularly controlled using reliable detection methods to guarantee their microbial safety.

  15. Biological stability of drinking water : Controlling factors, methods, and challenges

    NARCIS (Netherlands)

    Prest, E.I.E.D.; Hammes, F.; Van Loosdrecht, M.C.M.; Vrouwenvelder, J.S.

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and

  16. THE ROLE OF FARMERS IN MANAGING WATER Dr Tony Colman Professor Tony Allan Farmers manage about 92% of the water consumed by society which needs to recognise that farming practices and the decisions made by those who operate food supply chains - including corporates and those making public policy - determine how water is stewarded.

    Science.gov (United States)

    Colman, A. J.

    2017-12-01

    Title Food-water and society Dr. Tony Colman and Professor Tony Allan Abstract The purpose of the paper is to highlight some key relationships between water resources and society. First, water is an very important resource for society in that it provides an essential input to society's food supply chains. Secondly, it is an essential input to farmer livelihoods. About half of the families of the world still work in agriculture - albeit a declining proportion. Thirdly, farmers manage about 92% of the water consumed by society - including the blue water (surface and groundwater) for irrigation and the green water (effective rainfall) consumed on rainfed farms. They also account for about 66% of society's impacts on biodiversity and about 25% of emissions. Finally it will be argued that those who analyse allocation and management of water must recognise that farming practices and the decisions made by those who operate food supply chains - including corporates and those making public policy - must recognise that it is farmers and food consumers who determine how water is stewarded. It will be suggested that we need to understand that well informed consumers could be the regulators.

  17. Associations between perceptions of drinking water service delivery and measured drinking water quality in rural Alabama.

    Science.gov (United States)

    Wedgworth, Jessica C; Brown, Joe; Johnson, Pauline; Olson, Julie B; Elliott, Mark; Forehand, Rick; Stauber, Christine E

    2014-07-18

    Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure) and general aesthetic characteristics (taste, odor and color), providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets) and as-delivered from the distribution network (from outside flame-sterilized taps, if available), where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color). Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC) were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure-a risk factor for contamination-may be relatively reliable and therefore useful in future monitoring efforts.

  18. Associations between Perceptions of Drinking Water Service Delivery and Measured Drinking Water Quality in Rural Alabama

    Directory of Open Access Journals (Sweden)

    Jessica C. Wedgworth

    2014-07-01

    Full Text Available Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure and general aesthetic characteristics (taste, odor and color, providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets and as-delivered from the distribution network (from outside flame-sterilized taps, if available, where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color. Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure—a risk factor for contamination—may be relatively reliable and therefore useful in future monitoring efforts.

  19. Associations between Perceptions of Drinking Water Service Delivery and Measured Drinking Water Quality in Rural Alabama

    Science.gov (United States)

    Wedgworth, Jessica C.; Brown, Joe; Johnson, Pauline; Olson, Julie B.; Elliott, Mark; Forehand, Rick; Stauber, Christine E.

    2014-01-01

    Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure) and general aesthetic characteristics (taste, odor and color), providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets) and as-delivered from the distribution network (from outside flame-sterilized taps, if available), where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color). Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC) were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure—a risk factor for contamination—may be relatively reliable and therefore useful in future monitoring efforts. PMID:25046635

  20. On the Water-Food Nexus: an Optimization Approach for Water and Food Security

    Science.gov (United States)

    Mortada, Sarah; Abou Najm, Majdi; Yassine, Ali; Alameddine, Ibrahim; El-Fadel, Mutasem

    2016-04-01

    Water and food security is facing increased challenges with population increase, climate and land use change, as well as resource depletion coupled with pollution and unsustainable practices. Coordinated and effective management of limited natural resources have become an imperative to meet these challenges by optimizing the usage of resources under various constraints. In this study, an optimization model is developed for optimal resource allocation towards sustainable water and food security under nutritional, socio-economic, agricultural, environmental, and natural resources constraints. The core objective of this model is to maximize the composite water-food security status by recommending an optimal water and agricultural strategy. The model balances between the healthy nutritional demand side and the constrained supply side while considering the supply chain in between. It equally ensures that the population achieves recommended nutritional guidelines and population food-preferences by quantifying an optimum agricultural and water policy through transforming optimum food demands into optimum cropping policy given the water and land footprints of each crop or agricultural product. Through this process, water and food security are optimized considering factors that include crop-food transformation (food processing), water footprints, crop yields, climate, blue and green water resources, irrigation efficiency, arable land resources, soil texture, and economic policies. The model performance regarding agricultural practices and sustainable food and water security was successfully tested and verified both at a hypothetical and pilot scale levels.

  1. Water quality issues in southern Nigeria

    International Nuclear Information System (INIS)

    Ajayi, O.

    2000-07-01

    trace concentrations. Most of the ailments, including mood disturbances and psychological disorders, are reportedly on the increase in most urban and industrialized areas of Nigeria. Perhaps a study should be conducted among the population in order to relate the pattern of water pollution related diseases to health factors in Nigeria

  2. A Physiological Stimulating Factor of Water Intake during and after Dry Forage Feeding in Large-type Goats.

    Science.gov (United States)

    Van Thang, Tran; Sunagawa, Katsunori; Nagamine, Itsuki; Kishi, Tetsuya; Ogura, Go

    2012-04-01

    When ruminants consume dry forage, they also drink large volumes of water. The objective of this study was to clarify which factor produced when feed boluses enter the rumen is mainly responsible for the marked increase in water intake in the second hour of the 2 h feeding period in large-type goats fed on dry forage for 2 h twice daily. Six large-type male esophageal- and ruminal-fistulated goats (crossbred Japanese Saanen/Nubian, aged 2 to 6 years, weighing 85.1±4.89 kg) were used in two experiments. In experiment 1, the water deprivation (WD) control and the water availability (WA) treatment were conducted to compare changes in water intake during and after dry forage feeding. In experiment 2, a normal feeding conditions (NFC) control and a feed bolus removal (FBR) treatment were carried out to investigate whether decrease in circulating plasma volume or increase in plasma osmolality is mainly responsible for the marked increase in water intake in the second hour of the 2 h feeding period. The results of experiment 1 showed that in the WA treatment, small amounts of water were consumed during the first hour of feeding while the majority of water intake was observed during the second hour of the 2 h feeding period. Therefore, the amounts of water consumed in the second hour of the 2 h feeding period accounted for 82.8% of the total water intake. The results of experiment 2 indicated that in comparison with the NFC control, decrease in plasma volume in the FBR treatment, which was indicated by increase in hematocrit and plasma total protein concentrations, was higher (pforage feeding in large-type goats.

  3. Water Conservation and Economic Incentives

    Science.gov (United States)

    Narayanan, M.

    2016-12-01

    Water has played a vital role in the progress of human civilization throughout history. Both agriculture based economics as well as industry based economics totally rely upon water for survival and prosperity. Water could be a limiting factor in dictating day-to-day human activities and as such one should learn to live within the limits of available natural resources. Most of the water on this earth is either salty or undrinkable. Only one percent of world's water is available for all the needs of human civilization. This includes human personal household needs, community activities, agriculture, industry, plant and animal life sustenance. The supply of usable fresh water is finite and the per capita consumption of fresh water needs to be reduced in particularly in some selected regions of this world. The United States consumes about 450 billion gallons of water every day. The U.S. daily average of water pumped by public water supply systems is 185 gallons per person. The biggest water gobbler in a household is the lawn. Typically, at least 50% of water consumed by households is used outdoors. Even inside a house, bathroom facilities claim nearly 75% of the water used. Here is a short list of economic Incentives that may help water conservation. (1) Providing rebates, refunds or other economic incentives to those consumers that are willing to change to modern technological methods. Examples include, but not limited to energy efficient washing machines, low-flush toilets and improved shower head designs. (2) Communities should provide economic incentives to limit the type and size of landscaping. (3) Need, necessity and nature of outdoor water use could be restricted whenever possible. (4) Sprinkler ban may be deemed appropriate in extreme cases. (5) Set up hotlines that can help penalize those that ignore water conservation guidelines. (6) Incorporating water conservation monitors. References: http://www.nrdc.org/water/http://www.ecy.wa.gov/programs/wr/ws/wtrcnsv.htmlhttp://www.sscwd.org/tips.html

  4. Natural and anthropogenic factors affecting the shallow groundwater quality in a typical irrigation area with reclaimed water, North China Plain.

    Science.gov (United States)

    Gu, Xiaomin; Xiao, Yong; Yin, Shiyang; Pan, Xingyao; Niu, Yong; Shao, Jingli; Cui, Yali; Zhang, Qiulan; Hao, Qichen

    2017-09-22

    In this study, the hydrochemical characteristics of shallow groundwater were analyzed to get insight into the factors affecting groundwater quality in a typical agricultural dominated area of the North China Plain. Forty-four shallow groundwater samples were collected for chemical analysis. The water type changes from Ca·Na-HCO 3 type in grass land to Ca·Na-Cl (+NO 3 ) type and Na (Ca)-Cl (+NO 3 +SO 4 ) type in construction and facility agricultural land, indicating the influence of human activities. The factor analysis and geostatistical analysis revealed that the two major factors contributing to the groundwater hydrochemical compositions were the water-rock interaction and contamination from sewage discharge and agricultural fertilizers. The major ions (F, HCO 3 ) and trace element (As) in the shallow groundwater represented the natural origin, while the nitrate and sulfate concentrations were related to the application of fertilizer and sewage discharge in the facility agricultural area, which was mainly affected by the human activities. The values of pH, total dissolved solids, electric conductivity, and conventional component (K, Ca, Na, Mg, Cl) in shallow groundwater increased from grass land and cultivated land, to construction land and to facility agriculture which were originated from the combination sources of natural processes (e.g., water-rock interaction) and human activities (e.g., domestic effluents). The study indicated that both natural processes and human activities had influences on the groundwater hydrochemical compositions in shallow groundwater, while anthropogenic processes had more contribution, especially in the reclaimed water irrigation area.

  5. Introduction to the Special Issue: Water Grabbing? Focus on the (Reappropriation of Finite Water Resources

    Directory of Open Access Journals (Sweden)

    Lyla Mehta

    2012-06-01

    Full Text Available Recent large-scale land acquisitions for agricultural production (including biofuels, popularly known as 'land grabbing', have attracted headline attention. Water as both a target and driver of this phenomenon has been largely ignored despite the interconnectedness of water and land. This special issue aims to fill this gap and to widen and deepen the lens beyond the confines of the literature’s still limited focus on agriculture-driven resource grabbing. The articles in this collection demonstrate that the fluid nature of water and its hydrologic complexity often obscure how water grabbing takes place and what the associated impacts on the environment and diverse social groups are. The fluid properties of water interact with the 'slippery' nature of the grabbing processes: unequal power relations; fuzziness between legality and illegality and formal and informal rights; unclear administrative boundaries and jurisdictions, and fragmented negotiation processes. All these factors combined with the powerful material, discursive and symbolic characteristics of water make 'water grabbing' a site for conflict with potential drastic impacts on the current and future uses and benefits of water, rights as well as changes in tenure relations.

  6. Factors affecting the water holding capacity of red meat products: a review of recent research advances.

    Science.gov (United States)

    Cheng, Qiaofen; Sun, Da-Wen

    2008-02-01

    The water holding capacity of meat products is a very important quality attribute which has an influence on product yield, which in turn has economic implications, but is also important in terms of eating quality. A number of pre-and post-mortem factors influence the water holding capacity (WHC) of meat. During the growth and development of meat animals, genotype and animal diet are important due to their direct influence on muscle characteristics. In the immediate pre-slaughter period, stresses on the animal such as fasting, and different stunning methods are likely to influence meat WHC. In the post-slaughter period chilling, ageing, injecting non-meat ingredients, as well as tumbling have important influences on WHC. Furthermore, cooking and cooling procedures for the final meat products can also affect the WHC of the product, in particular the cooking and the cooling methods, the heating and the cooling rate, the cooking temperature, and the endpoint temperature. This paper provides an overview of recent research on important intrinsic and extrinsic factors that affect the WHC of beef, pork, and lamb products, and reveals explanations and solutions to some of the critical problems related to WHC and product quality.

  7. Household and Individual Risk Factors for Cholera among Cholera Vaccine Recipients in Rural Haiti.

    Science.gov (United States)

    Matias, Wilfredo R; Teng, Jessica E; Hilaire, Isabelle J; Harris, Jason B; Franke, Molly F; Ivers, Louise C

    2017-08-01

    Oral cholera vaccination was used as part of cholera control in Haiti, but the vaccine does not provide complete protection. We conducted secondary data analyses of a vaccine effectiveness study in Haiti to evaluate risk factors for cholera among cholera vaccine recipients. Individuals vaccinated against cholera that presented with acute watery diarrhea and had a stool sample positive for Vibrio cholerae O1 were included as cases. Up to four vaccinated individuals who did not present for treatment of diarrhea were included as controls for each case, and matched by location of residence, enrollment time, and age. We evaluated sociodemographic characteristics and risk factors for cholera. Univariable and multivariable logistic regression were performed to identify risk factors for cholera among vaccinees. Thirty-three vaccine recipients with culture-confirmed cholera were included as cases. One-hundred-and-seventeen of their matched controls reported receiving vaccine and were included as controls. In a multivariable analysis, self-reporting use of branded household water disinfection products as a means of treating water (adjusted relative risk [aRR] = 44.3, 95% confidence interval [CI] = 4.19-468.05, P = 0.002), and reporting having a latrine as the main household toilet (aRR = 4.22, 95% CI = 1.23-14.43, P = 0.02), were independent risk factors for cholera. Self-reporting always treating water (aRR = 0.09, 95% CI = 0.01-0.57, P = 0.01) was associated with protection against cholera. The field effectiveness of water, sanitation, and hygiene interventions used in combination with cholera vaccination in cholera control should be measured and monitored over time to identify and remediate shortcomings, and ensure successful impact on disease control.

  8. Water-quality observations of the San Antonio segment of the Edwards aquifer, Texas, with an emphasis on processes influencing nutrient and pesticide geochemistry and factors affecting aquifer vulnerability, 2010–16

    Science.gov (United States)

    Opsahl, Stephen P.; Musgrove, MaryLynn; Mahler, Barbara J.; Lambert, Rebecca B.

    2018-06-07

    As questions regarding the influence of increasing urbanization on water quality in the Edwards aquifer are raised, a better understanding of the sources, fate, and transport of compounds of concern in the aquifer—in particular, nutrients and pesticides—is needed to improve water management decision-making capabilities. The U.S. Geological Survey, in cooperation with the San Antonio Water System, performed a study from 2010 to 2016 to better understand how water quality changes under a range of hydrologic conditions and in contrasting land-cover settings (rural and urban) in the Edwards aquifer. The study design included continuous hydrologic monitoring, continuous water-quality monitoring, and discrete sample collection for a detailed characterization of water quality at a network of sites throughout the aquifer system. The sites were selected to encompass a “source-to-sink” (that is, from aquifer recharge to aquifer discharge) approach. Network sites were selected to characterize rainfall, recharging surface water, and groundwater; groundwater sites included wells in the unconfined part of the aquifer (unconfined wells) and in the confined part of the aquifer (confined wells) and a major discharging spring. Storm-related samples—including rainfall samples, stormwater-runoff (surface-water) samples, and groundwater samples—were collected to characterize the aquifer response to recharge.Elevated nitrate concentrations relative to national background values and the widespread detection of pesticides indicate that the Edwards aquifer is vulnerable to contamination and that vulnerability is affected by factors such as land cover, aquifer hydrogeology, and changes in hydrologic conditions. Greater vulnerability of groundwater in urban areas relative to rural areas was evident from results for urban groundwater sites, which generally had higher nitrate concentrations, elevated δ15N-nitrate values, a greater diversity of pesticides, and higher pesticide

  9. Urban water sustainability: framework and application

    Directory of Open Access Journals (Sweden)

    Wu Yang

    2016-12-01

    Full Text Available Urban areas such as megacities (those with populations greater than 10 million are hotspots of global water use and thus face intense water management challenges. Urban areas are influenced by local interactions between human and natural systems and interact with distant systems through flows of water, food, energy, people, information, and capital. However, analyses of water sustainability and the management of water flows in urban areas are often fragmented. There is a strong need to apply integrated frameworks to systematically analyze urban water dynamics and factors that influence these dynamics. We apply the framework of telecoupling (socioeconomic and environmental interactions over distances to analyze urban water issues, using Beijing as a demonstration megacity. Beijing exemplifies the global water sustainability challenge for urban settings. Like many other cities, Beijing has experienced drastic reductions in quantity and quality of both surface water and groundwater over the past several decades; it relies on the import of real and virtual water from sending systems to meet its demand for clean water, and releases polluted water to other systems (spillover systems. The integrative framework we present demonstrates the importance of considering socioeconomic and environmental interactions across telecoupled human and natural systems, which include not only Beijing (the water-receiving system but also water-sending systems and spillover systems. This framework helps integrate important components of local and distant human-nature interactions and incorporates a wide range of local couplings and telecouplings that affect water dynamics, which in turn generate significant socioeconomic and environmental consequences, including feedback effects. The application of the framework to Beijing reveals many research gaps and management needs. We also provide a foundation to apply the telecoupling framework to better understand and manage water

  10. Drinking water intake and source patterns within a US-Mexico border population.

    Science.gov (United States)

    Regnier, Adam; Gurian, Patrick; Mena, Kristina D

    2015-01-01

    This study was undertaken to identify water intake and source patterns among a population that resides in a hot, arid region on the US-Mexico border. A cross-sectional community-based survey was conducted among households in the neighbouring cities of El Paso, TX, USA and Ciudad Juárez, Chihuahua, Mexico to obtain data on the quantity and source of water consumed. The study was also designed to identify factors that impact water consumption patterns, including gender, demographics, socio-economic status, cultural characteristics, health status, types of occupations and residences, available water sources and outdoor temperature, among many others. Of all factors studied, outdoor air temperature was found to have the strongest impact upon water intake quantity. Specifically, among the survey participants, when the outdoor air temperature exceeded 90 °F, water consumption increased by 28 %. Additionally, it was found that participants in this region consumed approximately 50 % more water than the values reported in previous studies.

  11. An Assessment of Factors Having Impact on Water Quality in Water Supply Pipelines

    OpenAIRE

    Auksė Amosenkienė; Marina Valentukevičienė; Aušra Mažeikienė; Raimundas Kanapickas

    2011-01-01

    Water samples were collected from Vilnius drinking water distribution system fed by treated and different groundwater. Parameters related to bacterial growth have been measured considering these samples: temperature, concentration of free residual chlorine, ammonium, nitrates and nitrites. Results showed that treated groundwater was less susceptible to favour bacterial growth in the pipelines. The obtained results also showed that the potential growth induced by the distribution of treated wa...

  12. Perceptions of Water Ownership, Water Management, and the Responsibility of Providing Clean Water

    Directory of Open Access Journals (Sweden)

    Jacqueline Noga

    2013-11-01

    Full Text Available Perceptions of water and water related issues still render many under-researched topics. This study aims to further our knowledge regarding people’s perceptions of water and our understanding about the different ways individuals use water. The authors asked the question: Does the way an individual perceives water (i.e., as a commodity, a human right, private resource, public resource and/or natural resource influence consumption and conservation of water, and sentiments towards control and allocation of water? An exploratory online questionnaire was designed to generate qualitative and quantitative data of survey participants’ perceptions, beliefs and actions towards water issues, such as overconsumption and scarcity. Data analysis included comparison of the quantitative data regarding the non-statistical association between how an individual perceives water and the individual’s beliefs, as well as qualitative analysis of the comments using an iterative pattern coding technique. One hundred and sixty four individuals participated in the survey (75% completion rate and over 430 comments were made. Themes that emerged from the comments included: responsibility, scarcity, the value of water, knowledge gained and education needed. Comparison of the different perceptions of water revealed that different perceptions of what water is resulted in different beliefs about what the cost of water should be. These findings have implications for future water use, including what needs to change in order to increase appreciation for water issues.

  13. 30 CFR 250.1007 - What to include in applications.

    Science.gov (United States)

    2010-07-01

    ... features and other pertinent data including area, lease, and block designations; water depths; route...) submitted for a pipeline right-of-way shall bear a signed certificate upon its face by the engineer who made... additional design precautions you took to enable the pipeline to withstand the effects of water currents...

  14. Determination of self absorption correction factor (SAF) for gross alpha measurement in water samples by BIS method

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Baburajan, A.; Ravi, P.M.

    2018-01-01

    The laboratories accredited by AERB undertake the measurement of gross alpha and gross beta in packaged drinking water from manufactures across the country and analyze as per the procedure of Bureau of Indian standards. The accurate measurements of gross alpha in the drinking water sample is a challenge due to the self absorption of alpha particle from varying precipitate (Fe(OH) 3 +BaSO 4 ) thickness and total dissolved solids (TDS). This paper deals with a study on tracer recovery generation and self absorption correction factor (SAF). ESL, Tarapur has participated in an inter-laboratory comparison exercise conducted by IDS, RSSD, BARC as per the recommendation of AERB for the accredited laboratories. The thickness of the precipitate is an important aspect which affected the counting process. The activity was reported after conducting multiple experiments with uranium tracer recovery and precipitate thickness. Later on to make our efforts simplified, an average tracer recovery and Self Absorption correction Factor (SAF) was derived by the present experiment and the same was used for the re-calculation of activity from the count rate reported earlier

  15. Contributing Factors for Protein Calorie Malnutrition in Distsrict Mardan

    International Nuclear Information System (INIS)

    Khan, D.M.; Khan, S.A.

    2017-01-01

    Background: Protein calorie malnutrition (PCM) is a common health problem in developing countries resulting in high mortality in children under five years of age. It is also known as protein energy malnutrition. Objectives: To calculate the incidence and risk factors for Protein Calorie Malnutrition in children attending hospitals of district Mardan, Khyber Pakhtunkhwa. Study design, settings and duration: Retrospective hospital case record analysis of admitted children diagnosed as suffers of PCM and were admitted in hospitals from 2011-15 was done. Subjects and Methods: Children < 5 years fulfilling the inclusion criteria and reporting at four major hospitals of district Mardan from 2011-15 were included in the study. Data of children fulfilling the definition of PCM were further analyzed using SPSS software. Chi-square test and logistic regression model was used to determine the significance of the risk factors with the PCM disease. Results: Out of 448 children, 58.5 percent (n=262) had PCM and 41.5 percent (n=186) did not have PCM. The significant risk factors in the logistic model fitted for male children included economic status, number of living children, environmental sanitation, immunization, skin changes. Risk factors for PCM in female children were economic status, weight, height, number of living children, environmental sanitation, immunization, hair changes, time to time monitoring of the child and clean water availability. In the logistic model for both genders; the risk factors that showed significant association with PCM were economic status, weight, height, number of living children, environmental sanitation, immunization, hair changes, time to time monitoring of the child health, clean water availability and hypothermia. Conclusion: Almost 58 percent children admitted in different hospitals of district Mardan had PCM and the significant risk factors were economic status, weight, height, number of living children, environmental sanitation

  16. Uranium mineralization by ground water in sedimentary rocks, Japan

    International Nuclear Information System (INIS)

    Doi, K.; Hirono, S.; Sakamaki, Y.

    1975-01-01

    To solve the mechanism of uranium concentration in stratabound uranium deposits occurring in the basal part of Neogene sediments overlying granite basement, attention was paid to uranium leaching from weathered granite by circulating carbonated fissure waters, to effective adsorbents for fixing uranium from uraniferous ground waters, to structural features controlling the ground-water circulation, and other relevant factors. The evidence for uranium transportation by hydothermal solutions, including hot spring waters, is hard to observe. Conclusions are summarized as follows: Uranium in the deposits is supplied from surrounding source rocks, mostly from granite. Uranium is transported by circulating ground-water solutions. The uranium dissolved in ground water is fixed in minerals in various ways, the most important being adsorption by carbonaceous matter. Ore-grade uranium concentrated from very dilute solutions occurs by multiple repetition of a leaching-and-fixation cycle between minerals or adsorbents and circulating uraniferous ground water. Important factors for uranium mineralization are sufficient uranium, supplied mostly from granite, the existence of effective adsorbents such as carbonaceous matter in the host rocks, and favorable geological, geochemical, and geophysical environments. The last seem to require not only physical and chemical conditions but also correct flow and volume of ground water. (U.S.)

  17. Water availability, water quality water governance: the future ahead

    Science.gov (United States)

    Tundisi, J. G.; Matsumura-Tundisi, T.; Ciminelli, V. S.; Barbosa, F. A.

    2015-04-01

    The major challenge for achieving a sustainable future for water resources and water security is the integration of water availability, water quality and water governance. Water is unevenly distributed on Planet Earth and these disparities are cause of several economic, ecological and social differences in the societies of many countries and regions. As a consequence of human misuse, growth of urbanization and soil degradation, water quality is deteriorating continuously. Key components for the maintenance of water quantity and water quality are the vegetation cover of watersheds, reduction of the demand and new water governance that includes integrated management, predictive evaluation of impacts, and ecosystem services. Future research needs are discussed.

  18. Irrigation water as a source of drinking water: is safe use possible?

    Science.gov (United States)

    van der Hoek, W; Konradsen, F; Ensink, J H; Mudasser, M; Jensen, P K

    2001-01-01

    In arid and semi-arid countries there are often large areas where groundwater is brackish and where people have to obtain water from irrigation canals for all uses, including domestic ones. An alternative to drawing drinking water directly from irrigation canals or village water reservoirs is to use the water that has seeped from the irrigation canals and irrigated fields and that has formed a small layer of fresh water on top of the brackish groundwater. The objective of this study was to assess whether use of irrigation seepage water for drinking results in less diarrhoea than direct use of irrigation water and how irrigation water management would impact on health. The study was undertaken in an irrigated area in the southern Punjab, Pakistan. Over a one-year period, drinking water sources used and diarrhoea episodes were recorded each day for all individuals of 200 households in 10 villages. Separate surveys were undertaken to collect information on hygiene behaviour, sanitary facilities, and socio-economic status. Seepage water was of much better quality than surface water, but this did not translate into less diarrhoea. This could only be partially explained by the generally poor quality of water in the in-house storage vessels, reflecting considerable in-house contamination of drinking water. Risk factors for diarrhoea were absence of a water connection and water storage facility, lack of a toilet, low standard of hygiene, and low socio-economic status. The association between water quality and diarrhoea varied by the level of water availability and the presence or absence of a toilet. Among people having a high quantity of water available and a toilet, the incidence rate of diarrhoea was higher when surface water was used for drinking than when seepage water was used (relative risk 1.68; 95% CI 1.31-2.15). For people with less water available the direction of the association between water quality and diarrhoea was different (relative risk 0.80; 95% CI 0

  19. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000–2011

    Science.gov (United States)

    Tuyet-Hanh, Tran Thi; Lee, Jong-Koo; Oh, Juhwan; Van Minh, Hoang; Ou Lee, Chul; Hoan, Le Thi; Nam, You-Seon; Long, Tran Khanh

    2016-01-01

    Background Despite progress made by the Millennium Development Goal (MDG) number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. Objective This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Design Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011) describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. Results There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9–2.5) to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8–60.0). Conclusions More

  20. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000–2011

    Directory of Open Access Journals (Sweden)

    Tran Thi Tuyet-Hanh

    2016-02-01

    Full Text Available Background: Despite progress made by the Millennium Development Goal (MDG number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. Objective: This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Design: Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011 describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. Results: There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9–2.5 to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8–60

  1. Socio-economic factors influencing the spread of drinking water diseases in rural Africa: case study of Bondo sub-county, Kenya.

    Science.gov (United States)

    Rodrigues, Anthony Joachim; Oyoo, Wandiga Shem; Odundo, Francis O; Wambu, Enos W

    2015-06-01

    Socio-economic and medical information on Bondo sub-county community was studied to help establish the relationship between the water quality challenges, community health and water rights conditions. Health challenges have been linked to water quality and household income. A total of 1,510 households/respondents were studied by means of a questionnaire. About 69% of the households have no access to treated water. Although 92% of the respondents appear to be aware that treatment of water prevents waterborne diseases, the lowest income group and children share a high burden of waterborne diseases requiring hospitalization and causing mortality. Open defecation (12.3%) in these study areas contributes to a high incidence of waterborne diseases. The community's constitutional rights to quality water in adequate quantities are greatly infringed. The source of low-quality water is not a significant determinant of waterborne disease. The differences in poverty level in the sub-county are statistically insignificant and contribute less than other factors. Increased investment in water provision across regions, improved sanitation and availability of affordable point-of-use water purification systems will have major positive impacts on the health and economic well-being of the community.

  2. Wind effect on water surface of water reservoirs

    Directory of Open Access Journals (Sweden)

    Petr Pelikán

    2013-01-01

    Full Text Available The primary research of wind-water interactions was focused on coastal areas along the shores of world oceans and seas because a basic understanding of coastal meteorology is an important component in coastal and offshore design and planning. Over time the research showed the most important meteorological consideration relates to the dominant role of winds in wave generation. The rapid growth of building-up of dams in 20th century caused spreading of the water wave mechanics research to the inland water bodies. The attention was paid to the influence of waterwork on its vicinity, wave regime respectively, due to the shoreline deterioration, predominantly caused by wind waves. Consequently the similar principles of water wave mechanics are considered in conditions of water reservoirs. The paper deals with the fundamental factors associated with initial wind-water interactions resulting in the wave origination and growth. The aim of the paper is thepresentation of utilization of piece of knowledge from a part of sea hydrodynamics and new approach in its application in the conditions of inland water bodies with respect to actual state of the art. The authors compared foreign and national approach to the solved problems and worked out graphical interpretation and overview of related wind-water interaction factors.

  3. Soil and water losses in eucalyptus plantation and natural forest and determination of the USLE factors at a pilot sub-basin in Rio Grande do Sul, Brazil

    Directory of Open Access Journals (Sweden)

    Bárbara Pereira Christofaro Silva

    Full Text Available ABSTRACT Monitoring water erosion and the factors that control soil and water loss are essential for soil conservation planning. The objective of this study was to evaluate soil and water losses by water erosion under natural rainfall in eucalyptus plantations established in 2001 (EF2, and 2004 (EF1, native forest (NF and bare soil (BS, during the period of 2007 to 2012; and to determine the USLE factors: rain erosivity (R, erodibility (K of a Red Argisol and the cover-management factor (C for EF1, EF2 and NF at a pilot sub-basin, in Eldorado do Sul, RS, Brazil. The R factor was estimated by the EI30 index, using rainfall data from a gauging station located at the sub-basin. The soil and water losses were monitored in erosion plots, providing consistent data for the estimation of the K and C factors. The sub-basin presented an average erosivity of 4,228.52 MJ mm ha-1 h-1 yr-1. The average annual soil losses em EF1 and EF2 (0.81 e 0.12 Mg ha-1 year-1, respectively were below of the limit of tolerance, 12.9 Mg ha-1 year-1. The percentage values of water loss relating to the total rainfall decreased annually, approaching the values observed at the NF. From the 5th year on after the implantation of the eucalyptus systems, soil losses values were similar to the ones from NF. The erodibility of the Red Argisol was of 0.0026 Mg ha h ha-1 MJ-1mm-1 and the C factor presented values of 0.121, 0.016 and 0.015 for EF1, EF2 and NF, respectively.

  4. Corrosion Fatigue in District Heating Water Tanks

    DEFF Research Database (Denmark)

    Maahn, Ernst Emanuel

    1996-01-01

    Three candidate materials for construction of buffer tanks for district heating water have been tested for corrosion fatigue properties in a district heating water environment. The investigation included Slow Strain Rate Testing of plain tensile specimens, crack initiation testing by corrosion...... fatigue of plain tensile specimens and crack growth rate determination for Compact Tensile Specimens under corrosion fatigue conditions. The three materials are equal with respect to stress corrosion sensibility and crack initiation. Crack growth rate is increased with a factor of 4-6 relative to an inert...

  5. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    KAUST Repository

    Prest, Emmanuelle I.; Hammes, Frederik; van Loosdrecht, Mark C. M.; Vrouwenvelder, Johannes S.

    2016-01-01

    -depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order to maintain good drinking water microbial quality up

  6. Nitrification in Chloraminated Drinking Water Distribution Systems: Factors Affecting Occurrence

    Science.gov (United States)

    Drinking water distribution systems with ammonia present from either naturally occurring ammonia or ammonia addition during chloramination are at risk for nitrification. Nitrification in drinking water distribution systems is undesirable and may result in water quality degradatio...

  7. Overview of the National Water-Quality Assessment Program

    Science.gov (United States)

    Leahy, P.P.; Thompson, T.H.

    1994-01-01

    The Nation's water resources are the basis for life and our economic vitality. These resources support a complex web of human activities and fishery and wildlife needs that depend upon clean water. Demands for good-quality water for drinking, recreation, farming, and industry are rising, and as a result, the American public is concerned about the condition and sustainability of our water resources. The American public is asking: Is it safe to swim in and drink water from our rivers or lakes? Can we eat the fish that come from them? Is our ground water polluted? Is water quality degrading with time, and if so, why? Has all the money we've spent to clean up our waters, done any good? The U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program was designed to provide information that will help answer these questions. NAWQA is designed to assess historical, current, and future water-quality conditions in representative river basins and aquifers nationwide. One of the primary objectives of the program is to describe relations between natural factors, human activities, and water-quality conditions and to define those factors that most affect water quality in different parts of the Nation. The linkage of water quality to environmental processes is of fundamental importance to water-resource managers, planners, and policy makers. It provides a strong and unbiased basis for better decisionmaking by those responsible for making decisions that affect our water resources, including the United States Congress, Federal, State, and local agencies, environmental groups, and industry. Information from the NAWQA Program also will be useful for guiding research, monitoring, and regulatory activities in cost effective ways.

  8. REMOVING BIOMASS FROM WATER PONDS AND SMALL WATER RESERVOIRS BY USING NON-WOVEN FILTERS

    Directory of Open Access Journals (Sweden)

    Jakub Nieć

    2015-10-01

    Full Text Available Small water bodies, for example garden ponds, play many functions in the environment, including biocenotic, hydrological, climatic, sozological, landfill-creative, and aesthetic. Due to their small size, these reservoirs are sensitive to external and internal factors, they are also a common natural contaminants receivers. Nonwoven filters have been investigated for several years as a useful device for treatment of domestic wastewater pre-treated in a septic tank. The aim of this study was to verify the possibility of using this type of filters for water originating from small water body purification. The effectiveness of filters were tested on the water originating from the garden pond, contained high levels of nutrients and intensive algal bloom. Research was carried out on three filters (each filter consisted of four geotextile TS 20 layers. Basic water quality indicators: total suspended solids, turbidity, COD and BOD5, temperature, pH and dissolved oxygen were measured. The research results can be considered as satisfactory in terms of mechanical treatment (removal of turbidity and total suspended solids. An important positive effect of the filters was the oxygenation of the treated water, which is especially important for fish.

  9. Study of factors governing oil-water separation process using TiO₂ films prepared by spray deposition of nanoparticle dispersions.

    Science.gov (United States)

    Gondal, Mohammed A; Sadullah, Muhammad S; Dastageer, Mohamed A; McKinley, Gareth H; Panchanathan, Divya; Varanasi, Kripa K

    2014-08-27

    Surfaces which possess extraordinary water attraction or repellency depend on surface energy, surface chemistry, and nano- and microscale surface roughness. Synergistic superhydrophilic-underwater superoleophobic surfaces were fabricated by spray deposition of nanostructured TiO2 on stainless steel mesh substrates. The coated meshes were then used to study gravity driven oil-water separation, where only the water from the oil-water mixture is allowed to permeate through the mesh. Oil-water separation efficiencies of up to 99% could be achieved through the coated mesh of pore sizes 50 and 100 μm, compared to no separation at all, that was observed in the case of uncoated meshes of the same material and pore sizes. An adsorbed water on the TiO2 coated surface, formation of a water-film between the wires that form the mesh and the underwater superoleophobicity of the structured surface are the key factors that contribute to the enhanced efficiency observed in oil-water separation. The nature of the oil-water separation process using this coated mesh (in which the mesh allows water to pass through the porous structure but resists wetting by the oil phase) minimizes the fouling of mesh so that the need for frequent replacement of the separating medium is reduced. The fabrication approach presented here can be applied for coating large surface areas and to develop a large-scale oil-water separation facility for oil-field applications and petroleum industries.

  10. Factors Influencing Water Consumption in Multifamily Housing in Tempe Arizona

    Science.gov (United States)

    Wentz, E. A.

    2012-12-01

    Central to the "Smart Growth" movement is that compact development reduces vehicle miles traveled, carbon emissions, and water use. Empirical efforts to evaluate compact development have examined residential densities, but have not distinguished decreasing lot sizes from multifamily apartments as mechanisms for compact development. Efforts to link design features to water use have emphasized single-family at the expense of multifamily housing. This study isolates the determinants of water use in large (>50) unit apartment complexes in the city of Tempe, Arizona. In July 2007, per-bedroom water use increased with pool area, dishwashers, in-unit laundry facilities, and irrigated landscaping. We explain nearly 50% of the variation in water use with these variables. These results inform public policy for reducing water use in multifamily housing structures, suggesting strategies to construct and market "green" apartment units.

  11. Including policy and management in socio-hydrology models: initial conceptualizations

    Science.gov (United States)

    Hermans, Leon; Korbee, Dorien

    2017-04-01

    Socio-hydrology studies the interactions in coupled human-water systems. So far, the use of dynamic models that capture the direct feedback between societal and hydrological systems has been dominant. What has not yet been included with any particular emphasis, is the policy or management layer, which is a central element in for instance integrated water resources management (IWRM) or adaptive delta management (ADM). Studying the direct interactions between human-water systems generates knowledges that eventually helps influence these interactions in ways that may ensure better outcomes - for society and for the health and sustainability of water systems. This influence sometimes occurs through spontaneous emergence, uncoordinated by societal agents - private sector, citizens, consumers, water users. However, the term 'management' in IWRM and ADM also implies an additional coordinated attempt through various public actors. This contribution is a call to include the policy and management dimension more prominently into the research focus of the socio-hydrology field, and offers first conceptual variables that should be considered in attempts to include this policy or management layer in socio-hydrology models. This is done by drawing on existing frameworks to study policy processes throughout both planning and implementation phases. These include frameworks such as the advocacy coalition framework, collective learning and policy arrangements, which all emphasis longer-term dynamics and feedbacks between actor coalitions in strategic planning and implementation processes. A case about longter-term dynamics in the management of the Haringvliet in the Netherlands is used to illustrate the paper.

  12. Application of hydrodynamic cavitation in ballast water treatment.

    Science.gov (United States)

    Cvetković, Martina; Kompare, Boris; Klemenčič, Aleksandra Krivograd

    2015-05-01

    Ballast water is, together with hull fouling and aquaculture, considered the most important factor of the worldwide transfer of invasive non-indigenous organisms in aquatic ecosystems and the most important factor in European Union. With the aim of preventing and halting the spread of the transfer of invasive organisms in aquatic ecosystems and also in accordance with IMO's International Convention for the Control and Management of Ships Ballast Water and Sediments, the systems for ballast water treatment, whose work includes, e.g. chemical treatment, ozonation and filtration, are used. Although hydrodynamic cavitation (HC) is used in many different areas, such as science and engineering, implied acoustics, biomedicine, botany, chemistry and hydraulics, the application of HC in ballast water treatment area remains insufficiently researched. This paper presents the first literature review that studies lab- and large-scale setups for ballast water treatment together with the type-approved systems currently available on the market that use HC as a step in their operation. This paper deals with the possible advantages and disadvantages of such systems, as well as their influence on the crew and marine environment. It also analyses perspectives on the further development and application of HC in ballast water treatment.

  13. Assessment of Salicylic Acid Impacts on Seedling Characteristic of Cucumber (Cucumis sativus L. under Water Stress

    Directory of Open Access Journals (Sweden)

    Hossein MARDANI

    2012-02-01

    Full Text Available Impacts of various concentrations of salicylic acid (SA on cucumber (Cucumis sativus L. seedling characteristic were evaluated under different water stress levels by using a factorial arrangement based on completely randomized design with three replications at experimental greenhouse of Ferdowsi University of Mashhad, Iran. The studied factors included three water deficit levels (100% FC, 80% FC, and 60% FC considered as first factor and five levels of SA concentrations (0, 0.25, 0.5, 0.75, and 1 mM as second factor. Results showed that foliar application of SA at the highest concentration enhanced leaf area, leaf and dry weight while decreased stomatal conductance under high level of water deficit stress. Though, severe water deficit stress sharply raised the SPAD reading values. In general, exogenous SA application could develop cucumber seedling characteristic and improve water stress tolerance.

  14. Investigation of water sources as reservoirs of Vibrio cholerae in Bepanda, Douala and determination of physico-chemical factors maintaining its endemicity

    Directory of Open Access Journals (Sweden)

    Akoachere J.-F.K. Tatah

    2012-06-01

    Full Text Available Cholera remains a significant cause of mortality in developing countries. Outbreaks of the disease are associated with poverty, lack of potable water and poor sanitation. The survival and persistence of Vibrio cholerae in water has been shown to depend on physico-chemical factors. We studied water sources in Bepanda, an overcrowded neighbourhood in Douala, Cameroon, with limited access to portable water and very poor sanitary conditions as reservoirs of V. cholerae. We analysed 318 samples from various sources (well, tap, stream from February to July 2009 using standard microbiological techniques and characterised isolates serologically using the polyvalent O1/O139 antisera. Susceptibility to antibiotics previously used for cholera treatment in Douala was studied using the disk diffusion method. Physico-chemical factors (temperature, pH and salinity that could maintain the endemicity of the organism were analysed using standard methods. Eighty-seven (27.4% samples were contaminated, with high isolation rates being obtained from streams (52.4% and wells (29.8%. The number of isolates was significantly higher (P < 0.05 in the rainy season (35.5%. We detected 23 (24% O1 serogroup isolates in streams and wells, whilst 64 (66.6% were non-O1/non-O139. Temperature and salinity correlated positively with the occurrence of the organisms. All isolates were susceptible to fluoroquinolones but high resistance rates to trimethoprim or sulfamethozaxole and tetracycline were observed. Vibrio cholerae is endemic in Bepanda with O1 and non-O1/non-O139 serogroups co-existing in the streams and wells hence the possibility of future outbreaks of cholera if sanitation and drinking water quality are not improved. Temperature and salinity are amongst the factors maintaining the endemicity of the organism.

  15. Application of Information Technology Solution for Early Warning Systems at Water Utilities

    Directory of Open Access Journals (Sweden)

    Bałut Alicja

    2018-01-01

    Full Text Available Deployment of IT solutions in water utilities in Poland concerns nowadays lots beyond GIS implementation projects [1]. The scope of modern IT platforms is truly advanced software for complete management of water treatment processes and involved objects, including ranges of various types of equipment. There are multiply factors that disrupt required volumes of supplied water. They are normally classified as natural, accidental and intentional. This paper addresses potential residing in already deployed IT solutions of water utilities in and also in new ones being now developed. Primarily- from the perspective of intentional, terrorist threats. This document depicts operating procedures that are called in case of spotted contamination in a water supply (damage of key elements of the network infrastructure or in case of an introduction factors. This paper also discusses relevant IT tools with access provided to network operators or water plant owners that are extremely useful in accurate pinpointing the treat and in following relevant operating procedures and related actions.

  16. Application of Information Technology Solution for Early Warning Systems at Water Utilities

    Science.gov (United States)

    Bałut, Alicja

    2018-02-01

    Deployment of IT solutions in water utilities in Poland concerns nowadays lots beyond GIS implementation projects [1]. The scope of modern IT platforms is truly advanced software for complete management of water treatment processes and involved objects, including ranges of various types of equipment. There are multiply factors that disrupt required volumes of supplied water. They are normally classified as natural, accidental and intentional. This paper addresses potential residing in already deployed IT solutions of water utilities in and also in new ones being now developed. Primarily- from the perspective of intentional, terrorist threats. This document depicts operating procedures that are called in case of spotted contamination in a water supply (damage of key elements of the network infrastructure) or in case of an introduction factors. This paper also discusses relevant IT tools with access provided to network operators or water plant owners that are extremely useful in accurate pinpointing the treat and in following relevant operating procedures and related actions.

  17. A global water scarcity assessment under Shared Socio-economic Pathways – Part 1: Water use

    Directory of Open Access Journals (Sweden)

    N. Hanasaki

    2013-07-01

    Full Text Available A novel global water scarcity assessment for the 21st century is presented in a two-part paper. In this first paper, water use scenarios are presented for the latest global hydrological models. The scenarios are compatible with the socio-economic scenarios of the Shared Socio-economic Pathways (SSPs, which are a part of the latest set of scenarios on global change developed by the integrated assessment, the IAV (climate change impact, adaptation, and vulnerability assessment, and the climate modeling community. The SSPs depict five global situations based on substantially different socio-economic conditions during the 21st century. Water use scenarios were developed to reflect not only quantitative socio-economic factors, such as population and electricity production, but also key qualitative concepts such as the degree of technological change and overall environmental consciousness. Each scenario consists of five factors: irrigated area, crop intensity, irrigation efficiency, and withdrawal-based potential industrial and municipal water demands. The first three factors are used to estimate the potential irrigation water demand. All factors were developed using simple models based on a literature review and analysis of historical records. The factors are grid-based at a spatial resolution of 0.5° × 0.5° and cover the whole 21st century in five-year intervals. Each factor shows wide variation among the different global situations depicted: the irrigated area in 2085 varies between 2.7 × 106 and 4.5 × 106 km2, withdrawal-based potential industrial water demand between 246 and 1714 km3 yr−1, and municipal water between 573 and 1280 km3 yr−1. The water use scenarios can be used for global water scarcity assessments that identify the regions vulnerable to water scarcity and analyze the timing and magnitude of scarcity conditions.

  18. A decision support system prototype including human factors based on the TOGA meta-theory approach

    International Nuclear Information System (INIS)

    Cappelli, M.; Memmi, F.; Gadomski, A. M.; Sepielli, M.

    2012-01-01

    The human contribution to the risk of operation of complex technological systems is often not negligible and sometimes tends to become significant, as shown by many reports on incidents and accidents occurred in the past inside Nuclear Power Plants (NPPs). An error of a human operator of a NPP can derive by both omission and commission. For instance, complex commission errors can also lead to significant catastrophic technological accidents, as for the case of the Three Mile Island accident. Typically, the problem is analyzed by focusing on the single event chain that has provoked the incident or accident. What is needed is a general framework able to include as many parameters as possible, i.e. both technological and human factors. Such a general model could allow to envisage an omission or commission error before it can happen or, alternatively, suggest preferred actions to do in order to take countermeasures to neutralize the effect of the error before it becomes critical. In this paper, a preliminary Decision Support System (DSS) based on the so-called (-) TOGA meta-theory approach is presented. The application of such a theory to the management of nuclear power plants has been presented in the previous ICAPP 2011. Here, a human factor simulator prototype is proposed in order to include the effect of human errors in the decision path. The DSS has been developed using a TRIGA research reactor as reference plant, and implemented using the LabVIEW programming environment and the Finite State Machine (FSM) model The proposed DSS shows how to apply the Universal Reasoning Paradigm (URP) and the Universal Management Paradigm (UMP) to a real plant context. The DSS receives inputs from instrumentation data and gives as output a suggested decision. It is obtained as the result of an internal elaborating process based on a performance function. The latter, describes the degree of satisfaction and efficiency, which are dependent on the level of responsibility related to

  19. Concentration factors and aggregated transfer factors in selected bio-indicators from Sweden[Radioecology

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E.; Samuelsson, C.; Holstensson, M. [Lund Univ. (Sweden)

    2006-04-15

    Previously most common has been to use lichens and mosses in the terrestrial environment and mussels and algae in the marine environment. Several plants are promising and less commonly used such as ferns (e.g. Bracken, Pteridium aquilinum) and the fresh water plant, Water horsetail (Equisetum fluviatile). These show high uptake of radiocaesium but also accumulate plutonium and americium. Even if the uptake of transuranic elements is low, this behaviour is rather unique for plants. On bases of available data we have calculated concentration factors Cf and aggregated transfer factors, ATF according to their definitions i.e. Bq kg{sup -1} (biota)/Bq kg{sup -1}(water) and Bq kg{sup -1} (biota)/Bq m{sup -2} respectively. For earlier samples the water concentrations can only roughly be estimated while deposition data are rather well known. For fresh water samples it is a little awkward to use concentration factors since the uptake generally is not from water. Therefore a kind of Aggregated Transfer Factor has also been calculated on basis of using the same areal deposition in sediments as on land. We have used dry weight concentrations for biota. Data are presented for samples of various bio-medicator organisms. (LN)

  20. Effect of pressurized water reactor environment on fatigue crack propagation, including hole times

    International Nuclear Information System (INIS)

    Bamford, W.H.

    1976-01-01

    Results are presented from an experimental program being conducted to investigate the effects of pressurized water reactor environment on the fatigue crack growth rate of pressure vessel steels. Tests were conducted on precracked WOL type specimens under load controlled conditions. The effects of R ratio, loading rates, and loading wave form are evaluated, and the results are compared for both forging and plate material, as well as weldments

  1. Spatio-Temporal Trends and Identification of Correlated Variables with Water Quality for Drinking-Water Reservoirs.

    Science.gov (United States)

    Gu, Qing; Wang, Ke; Li, Jiadan; Ma, Ligang; Deng, Jinsong; Zheng, Kefeng; Zhang, Xiaobin; Sheng, Li

    2015-10-20

    It is widely accepted that characterizing the spatio-temporal trends of water quality parameters and identifying correlated variables with water quality are indispensable for the management and protection of water resources. In this study, cluster analysis was used to classify 56 typical drinking water reservoirs in Zhejiang Province into three groups representing different water quality levels, using data of four water quality parameters for the period 2006-2010. Then, the spatio-temporal trends in water quality were analyzed, assisted by geographic information systems (GIS) technology and statistical analysis. The results indicated that the water quality showed a trend of degradation from southwest to northeast, and the overall water quality level was exacerbated during the study period. Correlation analysis was used to evaluate the relationships between water quality parameters and ten independent variables grouped into four categories (land use, socio-economic factors, geographical features, and reservoir attributes). According to the correlation coefficients, land use and socio-economic indicators were identified as the most significant factors related to reservoir water quality. The results offer insights into the spatio-temporal variations of water quality parameters and factors impacting the water quality of drinking water reservoirs in Zhejiang Province, and they could assist managers in making effective strategies to better protect water resources.

  2. Spatio-Temporal Trends and Identification of Correlated Variables with Water Quality for Drinking-Water Reservoirs

    Directory of Open Access Journals (Sweden)

    Qing Gu

    2015-10-01

    Full Text Available It is widely accepted that characterizing the spatio-temporal trends of water quality parameters and identifying correlated variables with water quality are indispensable for the management and protection of water resources. In this study, cluster analysis was used to classify 56 typical drinking water reservoirs in Zhejiang Province into three groups representing different water quality levels, using data of four water quality parameters for the period 2006–2010. Then, the spatio-temporal trends in water quality were analyzed, assisted by geographic information systems (GIS technology and statistical analysis. The results indicated that the water quality showed a trend of degradation from southwest to northeast, and the overall water quality level was exacerbated during the study period. Correlation analysis was used to evaluate the relationships between water quality parameters and ten independent variables grouped into four categories (land use, socio-economic factors, geographical features, and reservoir attributes. According to the correlation coefficients, land use and socio-economic indicators were identified as the most significant factors related to reservoir water quality. The results offer insights into the spatio-temporal variations of water quality parameters and factors impacting the water quality of drinking water reservoirs in Zhejiang Province, and they could assist managers in making effective strategies to better protect water resources.

  3. Quantifying the influence of environmental and water conservation attitudes on household end use water consumption.

    Science.gov (United States)

    Willis, Rachelle M; Stewart, Rodney A; Panuwatwanich, Kriengsak; Williams, Philip R; Hollingsworth, Anna L

    2011-08-01

    Within the research field of urban water demand management, understanding the link between environmental and water conservation attitudes and observed end use water consumption has been limited. Through a mixed method research design incorporating field-based smart metering technology and questionnaire surveys, this paper reveals the relationship between environmental and water conservation attitudes and a domestic water end use break down for 132 detached households located in Gold Coast city, Australia. Using confirmatory factor analysis, attitudinal factors were developed and refined; households were then categorised based on these factors through cluster analysis technique. Results indicated that residents with very positive environmental and water conservation attitudes consumed significantly less water in total and across the behaviourally influenced end uses of shower, clothes washer, irrigation and tap, than those with moderately positive attitudinal concern. The paper concluded with implications for urban water demand management planning, policy and practice. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  4. Oil spill research : salt water and fresh water

    International Nuclear Information System (INIS)

    Goodman, R.

    2006-01-01

    The difference in oil spill response activities between marine and freshwater environments were reviewed. Although containment, recovery and in-situ burning remain the same in both environments, the fate of oil is different due to water density and salinity considerations. The lower energy of lakes and the lack of major currents changes the advection of the oil. Rivers have high currents, and wind speed and direction are highly influenced by topographic effects. Tidal action is not a consideration for the inland situation, but water levels in rivers can change due to sudden rain events or the action of control devices upstream from the spill. Typically, the volume of oil released in freshwater environments is lower than in marine tanker situations, but spills from pipelines or a major train derailment can exceed 1000 m 3 . Since the use of water for human consumption and irrigation is another important factor in inland spills, it is important to have a means of obtaining information on the dynamics of spills and a system for archiving the response activities, such as the shoreline cleanup assessment technique (SCAT)and resulting cleanup. It was suggested that research studies must be undertaken to improve response strategies for freshwater spills. These include the dynamics of oil in freshwater environments such as rivers, lakes and sloughs; the role of oil-fine interactions in freshwater situations; the process involved in the formation of tar balls; and, the dynamics of oil in a freshwater situation. The response techniques that must be developed to improve the response to freshwater spills include techniques to remove oil from the bottom; techniques to filter and remove oil from the water column; and, development and testing of dispersants for freshwater environments

  5. The dyad palindromic glutathione transferase P enhancer binds multiple factors including AP1.

    Science.gov (United States)

    Diccianni, M B; Imagawa, M; Muramatsu, M

    1992-10-11

    Glutathione Transferase P (GST-P) gene expression is dominantly regulated by an upstream enhancer (GPEI) consisting of a dyad of palindromically oriented imperfect TPA (12-O-tetradecanoyl-phorbol-13-acetate)-responsive elements (TRE). GPEI is active in AP1-lacking F9 cells as well in AP1-containing HeLa cells. Despite GPEI's similarity to a TRE, c-jun co-transfection has only a minimal effect on transactivation. Antisense c-jun and c-fos co-transfection experiments further demonstrate the lack of a role for AP1 in GPEI mediated trans-activation in F9 cells, although endogenously present AP1 can influence GPEI in HeLa cells. Co-transfection of delta fosB with c-jun, which forms an inactive c-Jun/delta FosB heterodimer that binds TRE sequences, inhibits GPEI-mediated transcription in AP1-lacking F9 cells as well as AP1-containing HeLa cells. These data suggest novel factor(s) other than AP1 are influencing GPEI. Binding studies reveal multiple nucleoproteins bind to GPEI. These factors are likely responsible for the high level of GPEI-mediated transcription observed in the absence of AP1 and during hepatocarcinogenesis.

  6. Aeromonas salmonicida bacteremia associated with chronic well water consumption in a patient with diabetes

    Directory of Open Access Journals (Sweden)

    Christine Ann Moore

    2017-01-01

    Full Text Available Aeromonas salmonicida is associated with superficial skin infections in fish. Its virulence factors allow colonization of water including surface water such as salt water, beaches, and fresh water wells. Moreover, it is possible for immunocompromised patients to develop invasive disease after chronic exposure to Aeromonas spp. through contaminated water. While there are reports of Aeromonas spp. bacteremia following water ingestion, there have been no reports of A. salmonicida bacteremia from water consumption. We report the first case of A. salmonicida bacteremia in a patient with diabetes due to chronic consumption of well water.

  7. Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2015-07-01

    Full Text Available Introduction Based on Task Group No. 43 (TG-43U1 recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods TG-43 parameters of low- and high-energy brachytherapy sources (i.e., Pd-103, I-125 and Cs-137 were obtained in different phantoms, using Monte Carlo simulations. The brachytherapy sources were simulated at the center of different phantoms including water, solid water, poly(methyl methacrylate, polystyrene and polyethylene. Dosimetric parameters such as dose rate constant, radial dose function and anisotropy function of each source were compared in different phantoms. Then, conversion factors were obtained to make phantom parameters equivalent to those of water. Results Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water. Conclusion Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water.

  8. Some factors affecting the metering of subcooled water with a choked venturi

    International Nuclear Information System (INIS)

    Fincke, J.R.; Collins, D.R.

    1981-01-01

    A series of experiments was performed to characterize the subcooled choking process in a convergent-divergent nozzle with a constant-area throat. The experiments were conducted in a low-pressure flow loop capable of a maximum water flow rate of 5.5 L/s with a pressure head of 300 kPa. The pressure and temperature upstream of the nozzle in the flow loop were adjusted between 90 and 300 kPa and 53 and 96 0 C, respectively. The variables measured in this study of critical flow phenomena were the flow rate, upstream pressure and temperature, and the axial wall pressure profiles in the nozzle. Critical mass flow rate data were acquired along five isotherms as a function of stagnation pressure. Factors affecting metering performance are examined

  9. Risk factors for exposure to influenza a viruses, including subtype H5 viruses, in Thai free-grazing ducks.

    Science.gov (United States)

    Beaudoin, A L; Kitikoon, P; Schreiner, P J; Singer, R S; Sasipreeyajan, J; Amonsin, A; Gramer, M R; Pakinsee, S; Bender, J B

    2014-08-01

    Free-grazing ducks (FGD) have been associated with highly pathogenic avian influenza (HPAI) H5N1 outbreaks and may be a viral reservoir. In July-August 2010, we assessed influenza exposure of Thai FGD and risk factors thereof. Serum from 6254 ducks was analysed with enzyme-linked immunosorbent assay (ELISA) to detect antibodies to influenza A nucleoprotein (NP), and haemagglutinin H5 protein. Eighty-five per cent (5305 ducks) were seropositive for influenza A. Of the NP-seropositive sera tested with H5 assays (n = 1423), 553 (39%) were H5 ELISA positive and 57 (4%) suspect. Twelve per cent (74 of 610) of H5 ELISA-positive/suspect ducks had H5 titres ≥ 1 : 20 by haemagglutination inhibition. Risk factors for influenza A seropositivity include older age, poultry contact, flock visitors and older purchase age. Study flocks had H5 virus exposure as recently as March 2010, but no HPAI H5N1 outbreaks have been identified in Thailand since 2008, highlighting a need for rigorous FGD surveillance. © 2012 Blackwell Verlag GmbH.

  10. Revelations of an overt water contamination.

    Science.gov (United States)

    Singh, Gurpreet; Kaushik, S K; Mukherji, S

    2017-07-01

    Contaminated water sources are major cause of water borne diseases of public health importance. Usually, contamination is suspected after an increase in patient load. Two health teams investigated the episode. First team conducted sanitary survey, and second team undertook water safety and morbidity survey. On-site testing was carried out from source till consumer end. Investigation was also undertaken to identify factors which masked the situation. Prevention and control measures included super chlorination, provision of alternate drinking water sources, awareness campaign, layout of new water pipeline bypassing place of contamination, repair of sewers, flushing and cleaning of water pipelines, and repeated water sampling and testing. Multiple sources of drinking water supply were detected. Water samples from consumer end showed 18 coliforms per 100 ml. Sewer cross connection with active leakage in water pipeline was found and this was confirmed by earth excavation. Water safety and morbidity survey found majority of households receiving contaminated water supply. This survey found no significant difference among households receiving contaminated water supply and those receiving clean water. Average proportion of household members with episode of loose motions, pain abdomen, vomiting, fever, and eye conditions was significantly more among households receiving contaminated water. The present study documents detailed methodology of investigation and control measures to be instituted on receipt of contaminated water samples. Effective surveillance mechanisms for drinking water supplies such as routine testing of water samples can identify water contamination at an early stage and prevent an impending outbreak.

  11. Electrocoagulation in Water Treatment

    Science.gov (United States)

    Liu, Huijuan; Zhao, Xu; Qu, Jiuhui

    Electrocoagulation (EC) is an electrochemical method of treating polluted water where sacrificial anodes corrode to release active coagulant precursors (usually aluminum or iron cations) into solution. At the cathode, gas evolves (usually as hydrogen bubbles) accompanying electrolytic reactions. EC needs simple equipments and is designable for virtually any size. It is cost effective and easily operable. Specially, the recent technical improvements combined with a growing need for small-scale water treatment facilities have led to a revaluation of EC. In this chapter, the basic principle of EC was introduced first. Following that, reactions at the electrodes and electrode assignment were reviewed; electrode passivation process and activation method were presented; comparison between electrocoagulation and chemical coagulation was performed; typical design of the EC reactors was also described; and factors affecting electrocoagulation including current density, effect of conductivity, temperature, and pH were introduced in details. Finally, application of EC in water treatment was given in details.

  12. Primary factors affecting water quality and quantity in four watersheds in Eastern Puerto Rico

    Science.gov (United States)

    Murphy, Sheila F.; Stallard, Robert F.

    2009-01-01

    As part of the U.S. Geological Survey (USGS) Water, Energy, and Biogeochemical Budgets (WEBB) program, four small watersheds in eastern Puerto Rico were monitored to identify and evaluate the effects of geology, landcover, atmospheric deposition, and other factors on stream water quality and quantity. Two catchments are located on coarse-grained granitic plutonic rocks, which weather to quartz- and clay-rich, sandy soils, and two are located on fine-grained volcanic rocks and volcaniclastic sediments, which weather to quartz-poor, fine-grained soils. These differing soil materials result in different hydrologic regimes. Soils on the granitic rocks have greater permeability than those developed on the volcaniclastic rocks, allowing more water infiltration and potentially greater landslide erosion rates. For each bedrock type, one catchment was covered with mature rainforest, and the other catchment was affected by agricultural practices typical of eastern Puerto Rico. These practices led to the erosion of much of the original surface soil in the agricultural watersheds, which introduced large quantities of sediment to stream channels. The agricultural watersheds are undergoing natural reforestation, like much of Puerto Rico. Eastern Puerto Rico receives large atmospheric inputs of marine salts, pollutants from the Northern Hemisphere, and Saharan Desert dust. Marine salts contribute over 80 percent of the ionic charge in precipitation, with peak inputs in January. Intense storms, mostly hurricanes, are associated with exceptionally high chloride concentrations in stream waters. Temperate pollution contributes nitrate, ammonia, and sulfate, with maximum inputs during northern cold fronts in January, April, and May. Pollution inputs have increased through time. Desert dust peaks in June and July, during times of maximum dust transport from the Saharan Desert across the Atlantic Ocean.

  13. Spectral reflectance relationships to leaf water stress

    Science.gov (United States)

    Ripple, William J.

    1986-01-01

    Spectral reflectance data were collected from detached snapbean leaves in the laboratory with a multiband radiometer. Four experiments were designed to study the spectral response resulting from changes in leaf cover, relative water content of leaves, and leaf water potential. Spectral regions included in the analysis were red (630-690 nm), NIR (760-900 nm), and mid-IR (2.08-2.35 microns). The red and mid-IR bands showed sensitivity to changes in both leaf cover and relative water content of leaves. The NIR was only highly sensitive to changes in leaf cover. Results provided evidence that mid-IR reflectance was governed primarily by leaf moisture content, although soil reflectance was an important factor when leaf cover was less than 100 percent. High correlations between leaf water potentials and reflectance were attributed to covariances with relative water content of leaves and leaf cover.

  14. Derivatization method of free cyanide including cyanogen chloride for the sensitive analysis of cyanide in chlorinated drinking water by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kang, Hye-In; Shin, Ho-Sang

    2015-01-20

    A novel derivatization method of free cyanide (HCN + CN(-)) including cyanogen chloride in chlorinated drinking water was developed with d-cysteine and hypochlorite. The optimum conditions (0.5 mM D-cysteine, 0.5 mM hypochlorite, pH 4.5, and a reaction time of 10 min at room temperature) were established by the variation of parameters. Cyanide (C(13)N(15)) was chosen as an internal standard. The formed β-thiocyanoalanine was directly injected into a liquid chromatography-tandem mass spectrometer without any additional extraction or purification procedures. Under the established conditions, the limits of detection and the limits of quantification were 0.07 and 0.2 μg/L, respectively, and the interday relative standard deviation was less than 4% at concentrations of 4.0, 20.0, and 100.0 μg/L. The method was successfully applied to determine CN(-) in chlorinated water samples. The detected concentration range and detection frequency of CN(-) were 0.20-8.42 μg/L (14/24) in source drinking water and 0.21-1.03 μg/L (18/24) in chlorinated drinking water.

  15. Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet

    Directory of Open Access Journals (Sweden)

    Mi T. Nguyen

    2017-12-01

    Full Text Available HighlightBacterial growth in fecally-contaminated water is highly variable and dependent on several factors.Regrowth occurs after chlorination (low doses, no residual.Indigenous microbial communities variably impact bacterial growth.A combination of treatments can both inactivate and inhibit growth.The Blue Diversion AUTARKY Toilet is a urine-diverting toilet with on-site treatment. The toilet is being developed to provide a safe and affordable sanitation technology for people who lack access to sewer-based sanitation. Water used for personal hygiene, hand washing, and flushing to rinse urine- and feces-collection bowls is treated, stored, and recycled for reuse to reduce reliance on external water supplies. The system provides an opportunity to investigate hygiene of water for reuse following treatment. Treatment in the toilet includes a Biologically Activated Membrane Bioreactor (BAMBi followed by a secondary treatment technology. To identify effective secondary treatment, three options, including granular activated carbon (GAC only, GAC+chlorine (sodium hypochlorite, and GAC+electrolysis are considered based on the bacterial inactivation and growth inhibition efficiency. Four different hygiene-relevant bacteria are tested: Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, and Salmonella typhimurium. Our evaluation demonstrates that—despite treatment of water with the BAMBi—E. coli, P. aeruginosa, and S. typhimurium have the potential to grow during storage in the absence of microbial competition. Including the indigenous microbial community influences bacterial growth in different ways: E. coli growth decreases but P. aeruginosa growth increases relative to no competition. The addition of the secondary treatment options considerably improves water quality. A column of GAC after the BAMBi reduces E. coli growth potential by 2 log10, likely due to the reduction of carbon sources. Additional treatments including chlorination

  16. Plutonium - its behavior in natural-water systems and assimilation by man

    International Nuclear Information System (INIS)

    Larsen, R.P.; Nelson, D.M.; Bhattacharyya, M.H.; Oldham, R.D.

    1981-01-01

    There are a number of factors which must be considered in establishing whether or not the inadvertent intrusion of a sizable amount of plutonium-bearing material into a natural-water system may have a significant impact on the health of those individuals who use that system as a drinking-water resource. These factors include the chemical form(s) and solubility of plutonium in natural waters, its behavior in relation to natural processes (geochemical and biological), its fate in water-treatment systems, and its uptake by man from drinking water. From the results obtained of the behavior in natural-water systems, it appears that (1) the chemical forms of plutonium dissolved in natural waters are Pu(IV) and Pu(V), (2) the soluble plutonium in many waters is bound to the organic constituents which probably enhance plutonium solubility, (3) the natural process responsible for the removal of plutonium from water is adsorption onto sediments, and (4) in water-treatment systems, soluble plutonium is oxidized to the VI state and this form is not removed. From investigations of gastrointestinal absorption, it appears that the value for f 1 , the fraction transferred from the gut to blood, is greater than 1 x 10 - 3 and may be as high as 2 x 10 - 1

  17. Factors Influencing Farmers’ Adoption of Soil and Water Control Technology (SWCT in Keita Valley, a Semi-Arid Area of Niger

    Directory of Open Access Journals (Sweden)

    Boureima Yacouba Karidjo

    2018-01-01

    Full Text Available The AderDoutchiMaggia in Niger, as with other Sahelian zones, undergoes a process of climatic deterioration, which combines with the growing social and economic needs of the increasing population and causes a general economic crisis. Land degradation due to biophysical factors requires that priority action be given to land reclamation and soil conservation and to activities intended to increase agricultural production. This paper takes a look at socio-economic and established factors affecting the adoption of soil and water control technology (SWCT in Keita valley, a semi-arid area in the central of Niger. Well-designed questionnaire survey on key agents was used to gather the indispensable data from farm ménages. The binary dichotomous logistic regression model prognosticated six factors to be affecting the adoption of soil and water control technology in Keita. These variables cover the gender of the respondent, age of the household’s head, income evolution within the family, small craft referring to off farm income, training provide by local institutions, use of credit and, possession of full rights on land and its resources. The results revealed that diffusion of adoption from local organized community is a good alternative to increase the adoption of soil and water control technology in Keita valley agriculture system in Niger. Researchers and policy makers should conceive proper strategies and agenda reflecting the farmers’ interest, position and restriction in advocating new technologies for greater assumption and adoption by the farmers.

  18. Parasitism can be a confounding factor in assessing the response of zebra mussels to water contamination.

    Science.gov (United States)

    Minguez, Laëtitia; Buronfosse, Thierry; Beisel, Jean-Nicolas; Giambérini, Laure

    2012-03-01

    Biological responses measured in aquatic organisms to monitor environmental pollution could be also affected by different biotic and abiotic factors. Among these environmental factors, parasitism has often been neglected even if infection by parasites is very frequent. In the present field investigation, the parasite infra-communities and zebra mussel biological responses were studied up- and downstream a waste water treatment plant in northeast France. In both sites, mussels were infected by ciliates and/or intracellular bacteria, but prevalence rates and infection intensities were different according to the habitat. Concerning the biological responses differences were observed related to the site quality and the infection status. Parasitism affects both systems but seemed to depend mainly on environmental conditions. The influence of parasites is not constant, but remains important to consider it as a potential confounding factor in ecotoxicological studies. This study also emphasizes the interesting use of integrative indexes to synthesize data set. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Bottled Water: United States Consumers and Their Perceptions of Water Quality

    OpenAIRE

    Hu, Zhihua; Morton, Lois Wright; Mahler, Robert L.

    2011-01-01

    Consumption of bottled water is increasing worldwide. Prior research shows many consumers believe bottled water is convenient and has better taste than tap water, despite reports of a number of water quality incidents with bottled water. The authors explore the demographic and social factors associated with bottled water users in the U.S. and the relationship between bottled water use and perceptions of the quality of local water supply. They find that U.S. consumers are more likely to report...

  20. Water Technology Lecture 3: Water Distribution

    OpenAIRE

    Gray, Nicholas Frederick

    2017-01-01

    This is the third lecture in the course Water Technology dealing with water distribution. This is a PowerPoint lecture which is free to use and modify. It was designed to be used in conjunction with the course text Gray, N.F. (2017) Water Science and Technology: An Introduction, published by CRC Press, Oxford. The basis of water distribution is explored including water pipe materials, distribution systems, leakage, water quality problems, pressure issue, water hydrants, effect of floods,...

  1. A systematic approach for the assessment of bacterial growth-controlling factors linked to biological stability of drinking water in distribution systems

    KAUST Repository

    Prest, E. I.

    2016-01-06

    A systematic approach is presented for the assessment of (i) bacterial growth-controlling factors in drinking water and (ii) the impact of distribution conditions on the extent of bacterial growth in full-scale distribution systems. The approach combines (i) quantification of changes in autochthonous bacterial cell concentrations in full-scale distribution systems with (ii) laboratoryscale batch bacterial growth potential tests of drinking water samples under defined conditions. The growth potential tests were done by direct incubation of water samples, without modification of the original bacterial flora, and with flow cytometric quantification of bacterial growth. This method was shown to be reproducible (ca. 4% relative standard deviation) and sensitive (detection of bacterial growth down to 5 μg L-1 of added assimilable organic carbon). The principle of step-wise assessment of bacterial growth-controlling factors was demonstrated on bottled water, shown to be primarily carbon limited at 133 (±18) × 103 cells mL-1 and secondarily limited by inorganic nutrients at 5,500 (±1,700) × 103 cells mL-1. Analysis of the effluent of a Dutch full-scale drinking water treatment plant showed (1) bacterial growth inhibition as a result of end-point chlorination, (2) organic carbon limitation at 192 (±72) × 103 cells mL-1 and (3) inorganic nutrient limitation at 375 (±31) × 103 cells mL-1. Significantly lower net bacterial growth was measured in the corresponding full-scale distribution system (176 (±25) × 103 cells mL-1) than in the laboratory-scale growth potential test of the same water (294 (±35) × 103 cells mL-1), highlighting the influence of distribution on bacterial growth. The systematic approach described herein provides quantitative information on the effect of drinking water properties and distribution system conditions on biological stability, which can assist water utilities in decision-making on treatment or distribution system improvements to

  2. Comparison between monitored and modeled pore water pressure and safety factor in a slope susceptible to shallow landslides

    Science.gov (United States)

    Bordoni, Massimiliano; Meisina, Claudia; Zizioli, Davide; Valentino, Roberto; Bittelli, Marco; Chersich, Silvia

    2014-05-01

    Shallow landslides can be defined as slope movements affecting superficial deposits of small thicknesses which are usually triggered due to extreme rainfall events, also very concentrated in time. Shallow landslides are hazardous phenomena: in particular, if they happen close to urbanized areas they could cause significant damages to cultivations, structures, infrastructures and, sometimes, human losses. The triggering mechanism of rainfall-induced shallow landslides is strictly linked with the hydrological and mechanical responses of usually unsaturated soils to rainfall events. For this reason, it is fundamental knowing the intrinsic hydro-mechanical properties of the soils in order to assess both susceptibility and hazard of shallow landslide and to develop early-warning systems at large scale. The hydrological data collected by a 20 months monitoring on a slope susceptible to shallow landslides in an area of the North -Eastern Oltrepo Pavese (Northern Apennines, Italy) were used to identify the hydrological behaviors of the investigated soils towards rainfall events. Field conditions under different rainfall trends have also been modeled by using both hydrological and physically-based stability models for the evaluation of the slope safety factor . The main objectives of this research are: (a) to compare the field measured pore water pressures at different depths with results of hydrological models, in order to evaluate the efficiency of the tested models and to determine how precipitations affect pore pressure development; (b) to compare the time trends of the safety factor that have been obtained by applying different stability models; (c) to evaluate, through a sensitivity analysis, the effects of soil hydrological properties on modeling pore water pressure and safety factor. The test site slope where field measurements were acquired is representative of other sites in Northern Apennines affected by shallow landslides and is characterized by medium

  3. Corroded scale analysis from water distribution pipes

    Directory of Open Access Journals (Sweden)

    Rajaković-Ognjanović Vladana N.

    2011-01-01

    Full Text Available The subject of this study was the steel pipes that are part of Belgrade's drinking water supply network. In order to investigate the mutual effects of corrosion and water quality, the corrosion scales on the pipes were analyzed. The idea was to improve control of corrosion processes and prevent impact of corrosion on water quality degradation. The instrumental methods for corrosion scales characterization used were: scanning electron microscopy (SEM, for the investigation of corrosion scales of the analyzed samples surfaces, X-ray diffraction (XRD, for the analysis of the presence of solid forms inside scales, scanning electron microscopy (SEM, for the microstructural analysis of the corroded scales, and BET adsorption isotherm for the surface area determination. Depending on the composition of water next to the pipe surface, corrosion of iron results in the formation of different compounds and solid phases. The composition and structure of the iron scales in the drinking water distribution pipes depends on the type of the metal and the composition of the aqueous phase. Their formation is probably governed by several factors that include water quality parameters such as pH, alkalinity, buffer intensity, natural organic matter (NOM concentration, and dissolved oxygen (DO concentration. Factors such as water flow patterns, seasonal fluctuations in temperature, and microbiological activity as well as water treatment practices such as application of corrosion inhibitors can also influence corrosion scale formation and growth. Therefore, the corrosion scales found in iron and steel pipes are expected to have unique features for each site. Compounds that are found in iron corrosion scales often include goethite, lepidocrocite, magnetite, hematite, ferrous oxide, siderite, ferrous hydroxide, ferric hydroxide, ferrihydrite, calcium carbonate and green rusts. Iron scales have characteristic features that include: corroded floor, porous core that contains

  4. Municipal water reclamation of industrial water use in Mexico

    International Nuclear Information System (INIS)

    Gamez, G.; Ramos, R.; Aerts, P.; Guzman, E.; Pachecho, J. c.

    2009-01-01

    This article describes how treated domestic wastewater in a Mexican desert area is reused by a local mining and metallurgical company for process water make-up. With increasing production of treated domestic wastewater, the company's water reuse facilities were continuously expanded over the last ten years. Today, four water reuse plants run with reverse osmosis membranes. With water being a limiting factor, they have enabled the scale-up of mining operations. (Author)

  5. Quantitative structure factor and density measurements of high-pressure fluids in diamond anvil cells by x-ray diffraction: Argon and water

    International Nuclear Information System (INIS)

    Eggert, Jon H.; Weck, Gunnar; Loubeyre, Paul; Mezouar, Mohamed

    2002-01-01

    We report quantitatively accurate high-pressure, structure-factor measurements of fluids in diamond anvil cells (DAC's) using x-ray diffraction. In the analysis of our diffraction data, we found it possible (and necessary) to determine the density directly. Thus, we also present a diffraction-based determination of the equation of state for fluid water. The analysis of these measurements is difficult since the diamond anvils are many times as thick as the sample and excessive care must be taken in the background subtraction. Due to the novel nature of the experiment and the complexity of the analysis, this paper is concerned primarily with a careful exposition of our analytical methods. Our analysis is applicable to both atomic and molecular fluids and glasses, and we present results for the structure factor and density of two relatively low-Z liquids: argon and water. In order to validate our methods we present an extensive comparison of our measurements on water at P≅0 in a DAC to recent state-of-the-art x-ray and neutron diffraction experiments and to first-principles simulations at ambient conditions

  6. Water Footprint and Impact of Water Consumption for Food, Feed, Fuel Crops Production in Thailand

    Directory of Open Access Journals (Sweden)

    Shabbir H. Gheewala

    2014-06-01

    Full Text Available The proliferation of food, feed and biofuels demands promises to increase pressure on water competition and stress, particularly for Thailand, which has a large agricultural base. This study assesses the water footprint of ten staple crops grown in different regions across the country and evaluates the impact of crop water use in different regions/watersheds by the water stress index and the indication of water deprivation potential. The ten crops include major rice, second rice, maize, soybean, mungbean, peanut, cassava, sugarcane, pineapple and oil palm. The water stress index of the 25 major watersheds in Thailand has been evaluated. The results show that there are high variations of crop water requirements grown in different regions due to many factors. However, based on the current cropping systems, the Northeastern region has the highest water requirement for both green water (or rain water and blue water (or irrigation water. Rice (paddy farming requires the highest amount of irrigation water, i.e., around 10,489 million m3/year followed by the maize, sugarcane, oil palm and cassava. Major rice cultivation induces the highest water deprivation, i.e., 1862 million m3H2Oeq/year; followed by sugarcane, second rice and cassava. The watersheds that have high risk on water competition due to increase in production of the ten crops considered are the Mun, Chi and Chao Phraya watersheds. The main contribution is from the second rice cultivation. Recommendations have been proposed for sustainable crops production in the future.

  7. Household water saving: Evidence from Spain

    Science.gov (United States)

    Aisa, Rosa; Larramona, Gemma

    2012-12-01

    This article focuses on household water use in Spain by analyzing the influence of a detailed set of factors. We find that, although the presence of both water-saving equipment and water-conservation habits leads to water savings, the factors that influence each are not the same. In particular, our results show that those individuals most committed to the adoption of water-saving equipment and, at the same time, less committed to water-conservation habits tend to have higher incomes.

  8. Identification of key factors in Accelerated Low Water Corrosion through experimental simulation of tidal conditions: influence of stimulated indigenous microbiota

    NARCIS (Netherlands)

    Marty, F.; Gueuné, H.; Malard, E.; Sánchez-Amaya, J.M.; Sjögren, L.; Abbas, B.; Quillet, L.; van Loosdrecht, M.C.M.; Muyzer, G.

    2014-01-01

    Biotic and abiotic factors favoring Accelerated Low Water Corrosion (ALWC) on harbor steel structures remain unclear warranting their study under controlled experimental tidal conditions. Initial stimulation of marine microbial consortia by a pulse of organic matter resulted in localized corrosion

  9. Hydriding failure in water reactor fuel elements

    International Nuclear Information System (INIS)

    Sah, D.N.; Ramadasan, E.; Unnikrishnan, K.

    1980-01-01

    Hydriding of the zircaloy cladding has been one of the important causes of failure in water reactor fuel elements. This report reviews the causes, the mechanisms and the methods for prevention of hydriding failure in zircaloy clad water reactor fuel elements. The different types of hydriding of zircaloy cladding have been classified. Various factors influencing zircaloy hydriding from internal and external sources in an operating fuel element have been brought out. The findings of post-irradiation examination of fuel elements from Indian reactors, with respect to clad hydriding and features of hydriding failure are included. (author)

  10. Agricultural adaptation to water scarcity in the Sri Lankan dry zone: A comparison of two water managment regimes

    Science.gov (United States)

    Burchfield, E. K.

    2014-12-01

    The island nation of Sri Lanka is divided into two agro-climatic zones: the southwestern wet zone and the northeastern dry zone. The dry zone is exposed to drought-like conditions for several months each year. Due to the sporadic nature of rainfall, dry zone livelihoods depend on the successful storage, capture, and distribution of water. Traditionally, water has been captured in rain-fed tanks and distributed through a system of dug canals. Recently, the Sri Lankan government has diverted the waters of the nation's largest river through a system of centrally managed reservoirs and canals and resettled farmers to cultivate this newly irrigated land. This study uses remotely sensed MODIS and LANDSAT imagery to compare vegetation health and cropping patterns in these distinct water management regimes under different conditions of water scarcity. Of particular interest are the socioeconomic, infrastructural, and institutional factors that affect cropping patterns, including field position, water storage capacity, and control of water resources. Results suggest that under known conditions of water scarcity, farmers cultivate other field crops in lieu of paddy. Cultivation changes depend to a large extent on the institutional distance between water users and water managers as well as the fragmentation of water resources within the system.

  11. Using FRAMES to Manage Environmental and Water Resources

    International Nuclear Information System (INIS)

    Whelan, Gene; Millard, W. David; Gelston, Gariann M.; Khangaonkar, Tarang P.; Pelton, Mitch A.; Strenge, Dennis L.; Yang, Zhaoqing; Lee, Cheegwan; Sivaraman, Chitra; Stephan, Alex J.; Hoopes, Bonnie L.; Castleton, Karl J.

    2007-01-01

    The Framework for Risk Analysis in Multimedia Environmental Systems (FRAMES) is decision-support middleware that provides users the ability to design software solutions for complex problems. It is a software platform that provides seamless and transparent communication between modeling components by using a multi-thematic approach to provide a flexible and holistic understanding of how environmental factors potentially affect humans and the environment. It incorporates disparate components (e.g., models, databases, and other frameworks) that integrate across scientific disciplines, allowing for tailored solutions to specific activities. This paper discusses one example application of FRAMES, where several commercial off-the-shelf (COTS) software products are seamlessly linked into a planning and decision-support tool that helps manage water-based emergency situations and sustainable response. Multiple COTS models, including three surface water models, and a number of databases are linked through FRAMES to assess the impact of three asymmetric and simultaneous events, two of which impact water resources. The asymmetric events include (1) an unconventional radioactive release into a large potable water body, (2) a conventional contaminant (oil) release into navigable waters, and (3) an instantaneous atmospheric radioactive release

  12. Factors affecting the release of radioactivity to the biosphere during deep geologic disposal of radioactive solids through underground water

    International Nuclear Information System (INIS)

    Solomah, A.G.

    1984-01-01

    The chemical alteration formed by ground water on the solidified radioactive waste during deep geologic disposal represents the most likely mechanism by which dangerous radioactive species could be reintroduced into the biosphere. Knowing the geologic history of the repository, the chemistry of the ground water and the mechanisms involved in the corrosion of the radioactive solids can provide help to predict the long-term stability of these materials. The factors that must be considered in order to assess the safety and the risk associated with such a disposal strategy are presented. The leaching behavior of a solidified radioactive waste form called SYNROC-B (SYNthetic ROCks) is discussed. Different simulated ground water brines similar to those of the repository sites were prepared and used as the leaching media in leaching experiments

  13. Drinking Water Quality of Water Vending Machines in Parit Raja, Batu Pahat, Johor

    Science.gov (United States)

    Hashim, N. H.; Yusop, H. M.

    2016-07-01

    An increased in demand from the consumer due to their perceptions on tap water quality is identified as one of the major factor on why they are mentally prepared to pay for the price of the better quality drinking water. The thought that filtered water quality including that are commercially available in the market such as mineral and bottled drinking water and from the drinking water vending machine makes they highly confident on the level of hygiene, safety and the mineral content of this type of drinking water. This study was investigated the vended water quality from the drinking water vending machine in eight locations in Parit Raja are in terms of pH, total dissolve solids (TDS), turbidity, mineral content (chromium, arsenic, cadmium, lead and nickel), total organic carbon (TOC), pH, total colony-forming units (CFU) and total coliform. All experiments were conducted in one month duration in triplicate samples for each sampling event. The results indicated the TDS and all heavy metals in eight vended water machines in Parit Raja area were found to be below the Food Act 1983, Regulation 360C (Standard for Packaged Drinking Water and Vended water, 2012) and Malaysian Drinking Water Quality, Ministry of Health 1983. No coliform was presence in any of the vended water samples. pH was found to be slightly excess the limit provided while turbidity was found to be 45 to 95 times more higher than 0.1 NTU as required by the Malaysian Food Act Regulation. The data obtained in this study would suggest the important of routine maintenance and inspection of vended water provider in order to maintain a good quality, hygienic and safety level of vended water.

  14. Water stress, water salience, and the implications for water supply planning

    Science.gov (United States)

    Garcia, M. E.; Islam, S.

    2017-12-01

    Effectively addressing the water supply challenges posed by urbanization and climate change requires a holistic understanding of the water supply system, including the impact of human behavior on system dynamics. Decision makers have limits to available information and information processing capacity, and their attention is not equally distributed among risks. The salience of a given risk is higher when increased attention is directed to it and though perceived risk may increase, real risk does not change. Relevant to water supply planning is how and when water stress results in an increased salience of water risks. This work takes a socio-hydrological approach to develop a water supply planning model that includes water consumption as an endogenous variable, in the context of Las Vegas, NV. To understand the benefits and limitations of this approach, this model is compared to a traditional planning model that uses water consumption scenarios. Both models are applied to project system reliability and water stress under four streamflow and demographic scenarios, and to assess supply side responses to changing conditions. The endogenous demand model enables the identification of feedback between both supply and demand management decisions on future water consumption and system performance. This model, while specific to the Las Vegas case, demonstrates a prototypical modeling framework capable of examining water-supply demand interactions by incorporating water stress driven conservation.

  15. Prevalence and distribution of Legionella spp in potable water systems in Germany, risk factors associated with contamination, and effectiveness of thermal disinfection.

    Science.gov (United States)

    Kruse, Eva-Brigitta; Wehner, Arno; Wisplinghoff, Hilmar

    2016-04-01

    Worldwide, Legionella spp are a common cause of community-acquired pneumonia. Potable water systems are a main reservoir; however, exposure in the community is unknown. Water samples from 718 buildings in Germany were collected. Possible risk factors were prospectively recorded. All samples were tested for Legionella spp using cultural microbiologic methods. Samples were assigned to 1 of 5 levels of contamination. Statistical analysis was performed to determine the influence of risk factors for contamination and, in a subgroup of buildings, for unsuccessful thermal disinfection. In total, 4,482 water samples from 718 different water supply systems were analyzed. In 233 buildings (32.7%), Legionella spp were identified, 148 (63.5%) of which had a medium or higher level of contamination. The most common species was Legionella pneumophila (94%). Contamination was strongly associated with temperature in the circulation, but not with the size of the building, time of the year, or transport time to the laboratory. Thermal disinfection was successful in fewer than half of the buildings. There is relevant exposure to Legionella spp in the community. Water systems are not always up to current technical standards. Although microbiological risk assessment remains a challenge, there is a case for monitoring for Legionella spp outside of hospitals. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Influence of pre- and post-usage flushing frequencies on bacterial water quality of non-touch water fittings.

    Science.gov (United States)

    Suchomel, Miranda; Diab-Elschahawi, Magda; Kundi, Michael; Assadian, Ojan

    2013-08-30

    Non-touch fittings have been reported to be susceptible for Pseudomonas aeruginosa accumulation. A number of factors may contribute to this, including the frequency of usage, duration of water stagnation, or presence of plastic materials. Programmable non-touch fittings are appearing which allow regular automated post-flushing with cold water to prevent water stagnation. However, the ideal duration of post-flushing is unknown as well as the effect of pre-rinsing with cold water before use. Eight non-touch fittings with brass valve blocks were mounted on a mobile test sink and connected to the same central water pipe source, differing only in presence or absence of water connection pipes, length of connection pipe, frequency of usage, and time intervals for pre- and post-usage water flush. The total bacteria colony-forming unit (cfu) counts were obtained by the spread plate technique. Low frequency of water use in combination with a long stagnating water column resulted in high bacterial cfu counts. Post-usage flushing for 2 seconds did not differ from no flushing. Flushing for 10 seconds with cold water after use or 30 seconds flush before use were both the most effective measures to prevent non-touch fittings from biofilm formation over a period of 20 weeks. Further improvements in water fitting technology could possibly solve the problem of bacterial water contamination in health care settings.

  17. Pesticides in Ground Water

    DEFF Research Database (Denmark)

    Bjerg, Poul Løgstrup

    1996-01-01

    Review af: Jack E. Barbash & Elizabeth A. Resek (1996). Pesticides in Ground Water. Distribution trends and governing factors. Ann Arbor Press, Inc. Chelsea, Michigan. pp 588.......Review af: Jack E. Barbash & Elizabeth A. Resek (1996). Pesticides in Ground Water. Distribution trends and governing factors. Ann Arbor Press, Inc. Chelsea, Michigan. pp 588....

  18. Effects of mine drainage on the River Hayle, Cornwall. Factors affecting concentrations of copper, zinc, and iron in water, sediments and dominant invertebrate fauna

    Energy Technology Data Exchange (ETDEWEB)

    Brown, B.E.

    1977-02-15

    Concentrations of copper, zinc and iron were measured in waters, sediments and invertebrates collected from the River Hayle. In river water at least 70% of copper and iron was associated with the ''particulate'' fraction whereas 80% of zinc was in the ''soluble'' form. Although total concentrations of zinc in water exceeded those of copper approximately ten fold, copper predominated over zinc in the sediments by a factor of approximately three. Iron was the most abundant metal recorded in both water and sediments. Seasonal differences in ''total'' metal content of waters suggested that concentrations of copper, zinc and iron increased during periods of high flow and decreased during lower flows. Copper concentrations in the sediment, unlike zinc and iron, showed markedly higher values during the summer sampling period when flows were minimal. In the ''free-living'' Trichoptera larvae, concentrations of copper and zinc in the tissue appeared to follow copper and zinc levels in the water. Similar relationships in Odonata and Plecoptera larvae were not obtained. Factors affecting animal/metal relationships are discussed with particular reference to adaptation shown by organisms exposed to high concentrations of heavy metals in their environment.

  19. Evolution of China's water issues as framed in Chinese mainstream media

    Science.gov (United States)

    Wei, Y.; Xiong, Y.; Zhang, Z.

    2016-12-01

    There is an urgent need globally to trigger fundamental societal changes in water use away from existing unsustainable paradigms. This paper attempts to understand the evolution of newspaper coverage of water issues in China by analyzing water-related articles in a major national newspaper People's Daily during 1946-2012 using a content analysis approach. The major findings include: 1) water issues have been in relatively important positions in the newspaper; 2) water issues reporting in China has experienced three stages: 1946- the middle of 1980s: flood and drought control and water for food; the middle of 1980s to 1997: water for economic development; and 1998 to the present: water for the environmental sustainability and economic development; 3) water issue reporting in the People's Daily clearly reflected China's top-down water resources management system, no "real" public opinions on water were reported during the study period; 4) The People's Daily is just a wind vane of Chinese mainstream values and policies on water. These findings supported the realist assumption that the societal changes on water issues in China were triggered by a multitude of factors including the biophysical pressure (floods and droughts), political campaign (the Cultural Revolution), macro-economic reform (Reform and Opening-up), water institutional arrangement (the Water Law) and water management reform (the No. 1 Central Document on water reform).

  20. Kinetic model of water disinfection using peracetic acid including synergistic effects.

    Science.gov (United States)

    Flores, Marina J; Brandi, Rodolfo J; Cassano, Alberto E; Labas, Marisol D

    2016-01-01

    The disinfection efficiencies of a commercial mixture of peracetic acid against Escherichia coli were studied in laboratory scale experiments. The joint and separate action of two disinfectant agents, hydrogen peroxide and peracetic acid, were evaluated in order to observe synergistic effects. A kinetic model for each component of the mixture and for the commercial mixture was proposed. Through simple mathematical equations, the model describes different stages of attack by disinfectants during the inactivation process. Based on the experiments and the kinetic parameters obtained, it could be established that the efficiency of hydrogen peroxide was much lower than that of peracetic acid alone. However, the contribution of hydrogen peroxide was very important in the commercial mixture. It should be noted that this improvement occurred only after peracetic acid had initiated the attack on the cell. This synergistic effect was successfully explained by the proposed scheme and was verified by experimental results. Besides providing a clearer mechanistic understanding of water disinfection, such models may improve our ability to design reactors.

  1. Factors affecting the local control of stereotactic body radiotherapy for lung tumors including primary lung cancer and metastatic lung tumors

    International Nuclear Information System (INIS)

    Hamamoto, Yasushi; Kataoka, Masaaki; Yamashita, Motohiro

    2012-01-01

    The purpose of this study was to identify factors affecting local control of stereotactic body radiotherapy (SBRT) for lung tumors including primary lung cancer and metastatic lung tumors. Between June 2006 and June 2009, 159 lung tumors in 144 patients (primary lung cancer, 128; metastatic lung tumor, 31) were treated with SBRT with 48-60 Gy (mean 50.1 Gy) in 4-5 fractions. Higher doses were given to larger tumors and metastatic tumors in principle. Assessed factors were age, gender, tumor origin (primary vs. metastatic), histological subtype, tumor size, tumor appearance (solid vs. ground glass opacity), maximum standardized uptake value of positron emission tomography using 18 F-fluoro-2-deoxy-D-glucose, and SBRT doses. Follow-up time was 1-60 months (median 18 months). The 1-, 2-, and 3-year local failure-free rates of all lesions were 90, 80, and 77%, respectively. On univariate analysis, metastatic tumors (p<0.0001), solid tumors (p=0.0246), and higher SBRT doses (p=0.0334) were the statistically significant unfavorable factors for local control. On multivariate analysis, only tumor origin was statistically significant (p=0.0027). The 2-year local failure-free rates of primary lung cancer and metastatic lung tumors were 87 and 50%, respectively. A metastatic tumor was the only independently significant unfavorable factor for local control after SBRT. (author)

  2. Calculation of the anti-trap factor in heavy water lattices

    International Nuclear Information System (INIS)

    Naudet, R.; Mougey, J.

    1965-01-01

    The calculation of the anti-trap factor of a lattice is complex when a large fraction of captures occurs in a range of energies where the spectrum in the fuel is considerably different from the simple dE/E law. This is particularly true for heavy water lattices in which the distances. between the bars are generally fairly large with respect to the slowing-down length. In order to take into account this effect it is necessary both to know the constitution of the effective resonance integral as a function of the energy, and to be able to calculate the distribution in the fuel. This report is devoted to these two problems. An improved method of treating the statistical domain makes it possible to plot the curves of the cross-sections per unit lethargy for various shapes of the fuel. Furthermore, the slowing-down of the neutrons is studied using a Monte-Carlo method which makes it possible in particular to take into account the perturbations caused by the non-moderating rods. A study is also made of the problem of shielding effects due to the captures themselves. (authors) [fr

  3. Water resources data, Kentucky. Water year 1991

    Energy Technology Data Exchange (ETDEWEB)

    McClain, D.L.; Byrd, F.D.; Brown, A.C.

    1991-12-31

    Water resources data for the 1991 water year for Kentucky consist of records of stage, discharge, and water quality of streams and lakes; and water-levels of wells. This report includes daily discharge records for 115 stream-gaging stations. It also includes water-quality data for 38 stations sampled at regular intervals. Also published are 13 daily temperature and 8 specific conductance records, and 85 miscellaneous temperature and specific conductance determinations for the gaging stations. Suspended-sediment data for 12 stations (of which 5 are daily) are also published. Ground-water levels are published for 23 recording and 117 partial sites. Precipitation data at a regular interval is published for 1 site. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurement and analyses. These data represent that part of the National Water Data System operated by the US Geological Survey and cooperation State and Federal agencies in Kentucky.

  4. New England's Drinking Water | Drinking Water in New ...

    Science.gov (United States)

    2017-07-06

    Information on Drinking Water in New England. Major Topics covered include: Conservation, Private Wells, Preventing Contamination, Drinking Water Sources, Consumer Confidence Reports, and Drinking Water Awards.

  5. Uncertainty assessment of source attribution of PM(2.5) and its water-soluble organic carbon content using different biomass burning tracers in positive matrix factorization analysis--a case study in Beijing, China.

    Science.gov (United States)

    Tao, Jun; Zhang, Leiming; Zhang, Renjian; Wu, Yunfei; Zhang, Zhisheng; Zhang, Xiaoling; Tang, Yixi; Cao, Junji; Zhang, Yuanhang

    2016-02-01

    Daily PM2.5 samples were collected at an urban site in Beijing during four one-month periods in 2009-2010, with each period in a different season. Samples were subject to chemical analysis for various chemical components including major water-soluble ions, organic carbon (OC) and water-soluble organic carbon (WSOC), element carbon (EC), trace elements, anhydrosugar levoglucosan (LG), and mannosan (MN). Three sets of source profiles of PM2.5 were first identified through positive matrix factorization (PMF) analysis using single or combined biomass tracers - non-sea salt potassium (nss-K(+)), LG, and a combination of nss-K(+) and LG. The six major source factors of PM2.5 included secondary inorganic aerosol, industrial pollution, soil dust, biomass burning, traffic emission, and coal burning, which were estimated to contribute 31±37%, 39±28%, 14±14%, 7±7%, 5±6%, and 4±8%, respectively, to PM2.5 mass if using the nss-K(+) source profiles, 22±19%, 29±17%, 20±20%, 13±13%, 12±10%, and 4±6%, respectively, if using the LG source profiles, and 21±17%, 31±18%, 19±19%, 11±12%, 14±11%, and 4±6%, respectively, if using the combined nss-K(+) and LG source profiles. The uncertainties in the estimation of biomass burning contributions to WSOC due to the different choices of biomass burning tracers were around 3% annually and up to 24% seasonally in terms of absolute percentage contributions, or on a factor of 1.7 annually and up to a factor of 3.3 seasonally in terms of the actual concentrations. The uncertainty from the major source (e.g. industrial pollution) was on a factor of 1.9 annually and up to a factor of 2.5 seasonally in the estimated WSOC concentrations. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Managing Uncertainty in Water Infrastructure Design Using Info-gap Robustness

    Science.gov (United States)

    Irias, X.; Cicala, D.

    2013-12-01

    Info-gap theory, a tool for managing deep uncertainty, can be of tremendous value for design of water systems in areas of high seismic risk. Maintaining reliable water service in those areas is subject to significant uncertainties including uncertainty of seismic loading, unknown seismic performance of infrastructure, uncertain costs of innovative seismic-resistant construction, unknown costs to repair seismic damage, unknown societal impacts from downtime, and more. Practically every major earthquake that strikes a population center reveals additional knowledge gaps. In situations of such deep uncertainty, info-gap can offer advantages over traditional approaches, whether deterministic approaches that use empirical safety factors to address the uncertainties involved, or probabilistic methods that attempt to characterize various stochastic properties and target a compromise between cost and reliability. The reason is that in situations of deep uncertainty, it may not be clear what safety factor would be reasonable, or even if any safety factor is sufficient to address the uncertainties, and we may lack data to characterize the situation probabilistically. Info-gap is a tool that recognizes up front that our best projection of the future may be wrong. Thus, rather than seeking a solution that is optimal for that projection, info-gap seeks a solution that works reasonably well for all plausible conditions. In other words, info-gap seeks solutions that are robust in the face of uncertainty. Info-gap has been used successfully across a wide range of disciplines including climate change science, project management, and structural design. EBMUD is currently using info-gap to help it gain insight into possible solutions for providing reliable water service to an island community within its service area. The island, containing about 75,000 customers, is particularly vulnerable to water supply disruption from earthquakes, since it has negligible water storage and is

  7. How proteins modify water dynamics

    Science.gov (United States)

    Persson, Filip; Söderhjelm, Pär; Halle, Bertil

    2018-06-01

    Much of biology happens at the protein-water interface, so all dynamical processes in this region are of fundamental importance. Local structural fluctuations in the hydration layer can be probed by 17O magnetic relaxation dispersion (MRD), which, at high frequencies, measures the integral of a biaxial rotational time correlation function (TCF)—the integral rotational correlation time. Numerous 17O MRD studies have demonstrated that this correlation time, when averaged over the first hydration shell, is longer than in bulk water by a factor 3-5. This rotational perturbation factor (RPF) has been corroborated by molecular dynamics simulations, which can also reveal the underlying molecular mechanisms. Here, we address several outstanding problems in this area by analyzing an extensive set of molecular dynamics data, including four globular proteins and three water models. The vexed issue of polarity versus topography as the primary determinant of hydration water dynamics is resolved by establishing a protein-invariant exponential dependence of the RPF on a simple confinement index. We conclude that the previously observed correlation of the RPF with surface polarity is a secondary effect of the correlation between polarity and confinement. Water rotation interpolates between a perturbed but bulk-like collective mechanism at low confinement and an exchange-mediated orientational randomization (EMOR) mechanism at high confinement. The EMOR process, which accounts for about half of the RPF, was not recognized in previous simulation studies, where only the early part of the TCF was examined. Based on the analysis of the experimentally relevant TCF over its full time course, we compare simulated and measured RPFs, finding a 30% discrepancy attributable to force field imperfections. We also compute the full 17O MRD profile, including the low-frequency dispersion produced by buried water molecules. Computing a local RPF for each hydration shell, we find that the

  8. Water repellents and water-repellent preservatives for wood

    Science.gov (United States)

    R. Sam. Williams; William C. Feist

    1999-01-01

    Water repellents and water-repellent preservatives increase the durability of wood by enabling the wood to repel liquid water. This report focuses on water-repellent finishes for wood exposed outdoors above ground. The report includes a discussion of the effects of outdoor exposure on wood, the characteristics of water repellent and water-repellent preservative...

  9. A constriction factor based particle swarm optimisation algorithm to solve the economic dispatch problem including losses

    Energy Technology Data Exchange (ETDEWEB)

    Young, Steven; Montakhab, Mohammad; Nouri, Hassan

    2011-07-15

    Economic dispatch (ED) is one of the most important problems to be solved in power generation as fractional percentage fuel reductions represent significant cost savings. ED wishes to optimise the power generated by each generating unit in a system in order to find the minimum operating cost at a required load demand, whilst ensuring both equality and inequality constraints are met. For the process of optimisation, a model must be created for each generating unit. The particle swarm optimisation technique is an evolutionary computation technique with one of the most powerful methods for solving global optimisation problems. The aim of this paper is to add in a constriction factor to the particle swarm optimisation algorithm (CFBPSO). Results show that the algorithm is very good at solving the ED problem and that CFBPSO must be able to work in a practical environment and so a valve point effect with transmission losses should be included in future work.

  10. Calculation of gamma ray dose buildup factors in water for isotropic point, plane mono directional and line sources using MCNP code

    International Nuclear Information System (INIS)

    Atak, H.; Celikten, O. S.; Tombakoglu, M.

    2009-01-01

    Gamma ray dose buildup factors in water for isotropic point, plane mono directional and infinite/finite line sources were calculated using the MCNP code. The buildup factors are determined for gamma ray energies of 1, 2, 3 and 4 Mev and for shield thicknesses of 1, 2, 4 and 7 mean free paths. The calculated buildup factors were then fitted in the Taylor and Berger forms. For the line sources a buildup factor table was also constructed using the Sievert function and the constants in Taylor form derived in this study to compare with the Monte Carlo results. All buildup factors were compared with the tabulated data given in literature. In order to reduce the statistical errors on buildup factors, 'forced collision' option was used in the MCNP calculations.

  11. Estimated water requirements for gold heap-leach operations

    Science.gov (United States)

    Bleiwas, Donald I.

    2012-01-01

    This report provides a perspective on the amount of water necessary for conventional gold heap-leach operations. Water is required for drilling and dust suppression during mining, for agglomeration and as leachate during ore processing, to support the workforce (requires water in potable form and for sanitation), for minesite reclamation, and to compensate for water lost to evaporation and leakage. Maintaining an adequate water balance is especially critical in areas where surface and groundwater are difficult to acquire because of unfavorable climatic conditions [arid conditions and (or) a high evaporation rate]; where there is competition with other uses, such as for agriculture, industry, and use by municipalities; and where compliance with regulatory requirements may restrict water usage. Estimating the water consumption of heap-leach operations requires an understanding of the heap-leach process itself. The task is fairly complex because, although they all share some common features, each gold heap-leach operation is unique. Also, estimating the water consumption requires a synthesis of several fields of science, including chemistry, ecology, geology, hydrology, and meteorology, as well as consideration of economic factors.

  12. Risk Factor Analysis for AKI Including Laboratory Indicators: a Nationwide Multicenter Study of Hospitalized Patients

    Directory of Open Access Journals (Sweden)

    Sasa Nie

    2017-10-01

    Full Text Available Background/Aims: Risk factor studies for acute kidney injury (AKI in China are lacking, especially those regarding non-traditional risk factors, such as laboratory indicators. Methods: All adult patients admitted to 38 tertiary and 22 secondary hospitals in China in any one month between July and December 2014 were surveyed. AKI patients were screened according to the Kidney Disease: Improving Global Outcomes’ definition of AKI. Logistic regression was used to analyze the risk factors for AKI, and Cox regression was used to analyze the risk of in-hospital mortality for AKI patients; additionally, a propensity score analysis was used to reconfirm the risk factors among laboratory indicators for mortality. Results: The morbidity of AKI was 0.97%. Independent risk factors for AKI were advancing age, male gender, hypertension, and chronic kidney disease. All-cause mortality was 16.5%. The predictors of mortality in AKI patients were advancing age, tumor, higher uric acid level and increases in Acute Physiologic Assessment and Chronic Health Evaluation II and Sequential Organ Failure Assessment scores. The hazard ratio (HR for mortality with uric acid levels > 9.1 mg/dl compared with ≤ 5.2 mg/dl was 1.78 (95% CI: 1.23 to 2.58 for the AKI patients as a group, and was 1.73 (95% CI: 1.24 to 2.42 for a propensity score-matched set. Conclusion: In addition to traditional risk factors, uric acid level is an independent predictor of all-cause mortality after AKI.

  13. 2005/2006 Southwest Florida Water Management District (SWFWMD) Lidar: Peace River South (including Carter Creek)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Light Detection and Ranging (LiDAR) LAS dataset is a survey of select areas within Southwest Florida. These data were produced for the Southwest Florida Water...

  14. Are extreme hydro-meteorological events a prerequisite for extreme water quality impacts? Exploring climate impacts on inland and coastal waters

    Science.gov (United States)

    Michalak, A. M.; Balaji, V.; Del Giudice, D.; Sinha, E.; Zhou, Y.; Ho, J. C.

    2017-12-01

    Questions surrounding water sustainability, climate change, and extreme events are often framed around water quantity - whether too much or too little. The massive impacts of extreme water quality impairments are equally compelling, however. Recent years have provided a host of compelling examples, with unprecedented harmful algal blooms developing along the West coast, in Utah Lake, in Lake Erie, and off the Florida coast, and huge hypoxic dead zones continuing to form in regions such as Lake Erie, the Chesapeake Bay, and the Gulf of Mexico. Linkages between climate change, extreme events, and water quality impacts are not well understood, however. Several factors explain this lack of understanding, including the relative complexity of underlying processes, the spatial and temporal scale mismatch between hydrologists and climatologists, and observational uncertainty leading to ambiguities in the historical record. Here, we draw on a number of recent studies that aim to quantitatively link meteorological variability and water quality impacts to test the hypothesis that extreme water quality impairments are the result of extreme hydro-meteorological events. We find that extreme hydro-meteorological events are neither always a necessary nor a sufficient condition for the occurrence of extreme water quality impacts. Rather, extreme water quality impairments often occur in situations where multiple contributing factors compound, which complicates both attribution of historical events and the ability to predict the future incidence of such events. Given the critical societal importance of water quality projections, a concerted program of uncertainty reduction encompassing observational and modeling components will be needed to examine situations where extreme weather plays an important, but not solitary, role in the chain of cause and effect.

  15. Load factor trends in light water reactor units

    International Nuclear Information System (INIS)

    Lehtinen, E.A.

    1990-01-01

    The Technical Research Centre of Finland follows up and analyses nuclear power plant availability performances worldwide. The results of a trend study for the load factors of the LWR units have been updated to the end of 1987. The whole operating history, in the sense of the annual and cumulative load factors achieved by all the Western commercial LWR units until the end of 1987, has been taken into consideration. Some trends in the load factors have been identified by using an exponential regression model developed. The LWR units form quite an inhomogeneous population with respect to their age, technical characteristics, site country as well as cumulative load factors achieved. The cumulative load factors achieved by all the LWR units until the end of 1987 are presented individually in the scattergrams

  16. A systematic approach for the assessment of bacterial growth-controlling factors linked to biological stability of drinking water in distribution systems

    KAUST Repository

    Prest, E. I.; Hammes, F.; Kotzsch, S.; van Loosdrecht, M. C. M.; Vrouwenvelder, Johannes S.

    2016-01-01

    A systematic approach is presented for the assessment of (i) bacterial growth-controlling factors in drinking water and (ii) the impact of distribution conditions on the extent of bacterial growth in full-scale distribution systems. The approach

  17. Ecological study on chronic kidney disease and arsenic in drinking water in districts of Guanacaste

    Directory of Open Access Journals (Sweden)

    Darner Mora-Alvarado

    2015-06-01

    Recommendations: cross sectional and case/control studies should be done, without neglecting any hypothesis regarding the common risk factors in the CKD affected districts, including exposure to pesticides, high temperature, heavy metals (including total-As in drinking water agrochemicals, agricultural occupation, among others.

  18. Geospatial data to support analysis of water-quality conditions in basin-fill aquifers in the southwestern United States

    Science.gov (United States)

    McKinney, Tim S.; Anning, David W.

    2009-01-01

    The Southwest Principal Aquifers study area consists of most of California and Nevada and parts of Utah, Arizona, New Mexico, and Colorado; it is about 409,000 square miles. The Basin-fill aquifers extend through about 201,000 square miles of the study area and are the primary source of water for cities and agricultural communities in basins in the arid and semiarid southwestern United States (Southwest). The demand on limited ground-water resources in areas in the southwestern United States has increased significantly. This increased demand underscores the importance of understanding factors that affect the water quality in basin-fill aquifers in the region, which are being studied through the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program. As a part of this study, spatial datasets of natural and anthropogenic factors that may affect ground-water quality of the basin-fill aquifers in the southwestern United States were developed. These data include physical characteristics of the region, such as geology, elevation, and precipitation, as well as anthropogenic factors, including population, land use, and water use. Spatial statistics for the alluvial basins in the Southwest have been calculated using the datasets. This information provides a foundation for the development of conceptual and statistical models that relate natural and anthropogenic factors to ground-water quality across the Southwest. A geographic information system (GIS) was used to determine and illustrate the spatial distribution of these basin-fill variables across the region. One hundred-meter resolution raster data layers that represent the spatial characteristics of the basins' boundaries, drainage areas, population densities, land use, and water use were developed for the entire Southwest.

  19. Impact of the water symmetry factor on humidification and cooling strategies for PEM fuel cell stacks

    Energy Technology Data Exchange (ETDEWEB)

    Picot, D; Metkemeijer, R; Bezian, J J; Rouveyre, L [Centre d` Energetique, Ecole des Mines de Paris, 06 - Sophia Antipolis (France)

    1998-10-01

    In this paper, experimental water and thermal balances with three proton exchange membrane fuel cells (PEMFC) are proposed. On the test facility of Ecole des Mines de Paris, three De Nora SPA fuel cell stacks have been successfully studied: An 1 kW{sub e} prototype using Nafion {sup trademark} 117, a 5 and 10 kW{sub e} module using Nafion {sup trademark} 115. The averaged water symmetry factor determines strategies to avoid drying membrane. So, we propose analytical solutions to find compromises between humidification and cooling conditions, which determines outlet temperatures of gases. For transport applications, the space occupied by the power module must be reduced. One of the main efforts consists in decreasing the operative pressure. Thus, if adequate cooling power is applied, we show experimentally and theoretically the possibility to use De Nora PEM fuel cells with low pressure, without specific external humidification. (orig.)

  20. Factors controlling the regional distribution of vanadium in ground water

    Science.gov (United States)

    Wright, Michael T.; Belitz, Kenneth

    2010-01-01

    Although the ingestion of vanadium (V) in drinking water may have possible adverse health effects, there have been relatively few studies of V in groundwater. Given the importance of groundwater as a source of drinking water in many areas of the world, this study examines the potential sources and geochemical processes that control the distribution of V in groundwater on a regional scale. Potential sources of V to groundwater include dissolution of V rich rocks, and waste streams from industrial processes. Geochemical processes such as adsorption/desorption, precipitation/dissolution, and chemical transformations control V concentrations in groundwater. Based on thermodynamic data and laboratory studies, V concentrations are expected to be highest in samples collected from oxic and alkaline groundwater. However, the extent to which thermodynamic data and laboratory results apply to the actual distribution of V in groundwater is not well understood. More than 8400 groundwater samples collected in California were used in this study. Of these samples, high (> or = 50 μg/L) and moderate (25 to 49 μg/L) V concentrations were most frequently detected in regions where both source rock and favorable geochemical conditions occurred. The distribution of V concentrations in groundwater samples suggests that significant sources of V are mafic and andesitic rock. Anthropogenic activities do not appear to be a significant contributor of V to groundwater in this study. High V concentrations in groundwater samples analyzed in this study were almost always associated with oxic and alkaline groundwater conditions, which is consistent with predictions based on thermodynamic data.

  1. Simulation with Phast of the pore water chemistry experiment results (Mont Terri Url, Switzerland), including transport, thermodynamics, kinetics, and biological activity

    International Nuclear Information System (INIS)

    Tournassat, C.; Gaucher, E.; Pearson, F.J.; Mettler, S.; Wersin, P.

    2005-01-01

    Full text of publication follows: The Pore water Chemistry (PC-)experiment was initially designed to determine the processes that control the redox properties of pore water in the Opalinus Clay at the Mont Terri URL. However, changes in isotopic data and chemical parameters such as pH, alkalinity, dissolved methane, acetate and sulphate concentrations indicated unexpected microbial activity. The origin of the bacteria is not clear. In the light of published data, an indigenous origin cannot be ruled out. A combined biological and reactive transport model has been developed with the parallel PHAST software to simulate the processes that determine pore water chemistry. The influence of bacterial activity on the system is successfully modelled by considering different reaction pathways scenarios including aceto-genesis, methano-genesis, and methane/acetate oxidation coupled to sulphate reduction. Several conclusions can be clearly stated in the light of the simulation results: - The measured redox potentials (redox electrode) are in line with the S(-II)/S(+VI) redox system. - In the undisturbed pore water, S(-II) and S(+VI) activities are controlled by a mineral assemblage containing pyrite and a Fe carbonate (siderite or ankerite). pH is buffered by mineral phases and SO 4 2- concentration is inherited from the marine sedimentary rock. - Some local redox potentials in the sedimentary rock do not correspond to the measured redox potential; for instance, organic matter/HCO 3 - and CH 4 /HCO 3 - systems are not at equilibrium with the measured redox potential. - Redox disequilibrium can be exploited by micro-organisms as a source of energy for their metabolism. In this experiment CH 4 , acetate and other organic acids were produced and SO 4 2- was reduced to HS - . The redox properties of the system are then governed by kinetics rather than by thermodynamic equilibrium. The unexpected persistence of acetate in the borehole water is one of the consequences of these

  2. Modeling Water Resource Systems Accounting for Water-Related Energy Use, GHG Emissions and Water-Dependent Energy Generation in California

    Science.gov (United States)

    Escriva-Bou, A.; Lund, J. R.; Pulido-Velazquez, M.; Medellin-Azuara, J.

    2015-12-01

    Most individual processes relating water and energy interdependence have been assessed in many different ways over the last decade. It is time to step up and include the results of these studies in management by proportionating a tool for integrating these processes in decision-making to effectively understand the tradeoffs between water and energy from management options and scenarios. A simple but powerful decision support system (DSS) for water management is described that includes water-related energy use and GHG emissions not solely from the water operations, but also from final water end uses, including demands from cities, agriculture, environment and the energy sector. Because one of the main drivers of energy use and GHG emissions is water pumping from aquifers, the DSS combines a surface water management model with a simple groundwater model, accounting for their interrelationships. The model also explicitly includes economic data to optimize water use across sectors during shortages and calculate return flows from different uses. Capabilities of the DSS are demonstrated on a case study over California's intertied water system. Results show that urban end uses account for most GHG emissions of the entire water cycle, but large water conveyance produces significant peaks over the summer season. Also the development of more efficient water application on the agricultural sector has increased the total energy consumption and the net water use in the basins.

  3. Cryptosporidium spp. and Giardia spp. in feces and water and the associated exposure factors on dairy farms.

    Directory of Open Access Journals (Sweden)

    Roberta Dos Santos Toledo

    Full Text Available The aims of this study were to verify the prevalence of Cryptosporidium spp. and Giardia spp. in animal feces and drinking water on dairy farms and to identify a possible relation between the exposure factors and the presence of these parasites. Fecal samples from cattle and humans and water samples were collected on dairy farms in Paraná, Brazil. Analysis of (oocysts in the feces was performed by the modified Ziehl-Neelsen staining and centrifugal flotation in zinc sulfate. Test-positive samples were subjected to nested PCR amplification of the 18SSU ribosomal RNA gene for identification of Cryptosporidium and Giardia and of the gp60 gene for subtyping of Cryptosporidium. Microbiological analysis of water was carried out by the multiple-tube method and by means of a chromogenic substrate, and parasitological analysis was performed on 31 samples by direct immunofluorescence and nested PCR of the genes mentioned above. Identification of the species of Cryptosporidium was performed by sequencing and PCR with analysis of restriction fragment length polymorphisms. The prevalence of Giardia and Cryptosporidium was higher in calves than in adults. Among the samples of cattle feces, Cryptosporidium parvum was identified in 41 (64%, C. ryanae in eight (12.5%, C. bovis in four (6.3%, C. andersoni in five (7.8%, and a mixed infection in 20 samples (31.3%. These parasites were not identified in the samples of human feces. Thermotolerant coliform bacteria were identified in 25 samples of water (45.5%. Giardia duodenalis and C. parvum were identified in three water samples. The gp60 gene analysis of C. parvum isolates revealed the presence of two strains (IIaA20G1R1 and IIaA17G2R2 in the fecal samples and one (IIaA17G2R1 in the water samples. The presence of coliforms was associated with the water source, structure and degradation of springs, rain, and turbidity. The prevalence of protozoa was higher in calves up to six months of age. C. parvum and G

  4. Corrosion fatigue cracking behavior of Inconel 690 (TT) in secondary water of pressurized water reactors

    International Nuclear Information System (INIS)

    Xiao Jun; Chen Luyao; Qiu Shaoyu; Chen Yong; Lin Zhenxia; Fu Zhenghong

    2015-01-01

    Inconel 690 (TT) is one of the key materials for tubes of steam generators for pressurized water reactors, where it is susceptible to corrosion fatigue cracking. In this paper, the corrosion fatigue cracking behavior of Inconel 690 (TT) was investigated under small scale yielding conditions, in the simulated secondary water of pressurized water reactor. It was observed that the fatigue crack growth rate was accelerated by a maximum factor up to 3 in the simulated secondary water, comparing to that in room temperature air. In addition, it was found that the accelerating effect was influenced by out-of-plane cracking of corrosion fatigue cracks and also correlated with stress intensity factor range, maximum stress intensity factor and stress ratio. (authors)

  5. Nanofiltration technology in water treatment and reuse: applications and costs.

    Science.gov (United States)

    Shahmansouri, Arash; Bellona, Christopher

    2015-01-01

    Nanofiltration (NF) is a relatively recent development in membrane technology with characteristics that fall between ultrafiltration and reverse osmosis (RO). While RO membranes dominate the seawater desalination industry, NF is employed in a variety of water and wastewater treatment and industrial applications for the selective removal of ions and organic substances, as well as certain niche seawater desalination applications. The purpose of this study was to review the application of NF membranes in the water and wastewater industry including water softening and color removal, industrial wastewater treatment, water reuse, and desalination. Basic economic analyses were also performed to compare the profitability of using NF membranes over alternative processes. Although any detailed cost estimation is hampered by some uncertainty (e.g. applicability of estimation methods to large-scale systems, labor costs in different areas of the world), NF was found to be a cost-effective technology for certain investigated applications. The selection of NF over other treatment technologies, however, is dependent on several factors including pretreatment requirements, influent water quality, treatment facility capacity, and treatment goals.

  6. Research on the water resources regulation ability model of dams in the Huai He River Basin considering ecological and management factors

    Science.gov (United States)

    Shui, Y.; Liu, H. C.; Li, L. H.; Yu, G. G.; Liu, J.

    2016-08-01

    Research that assesses the scheduling ability of dams gamers a great deal of attention due to the global water resource crisis. These studies can provide useful and practical suggestions for scheduling the water resources of dams to solve problems, such as addressing ecological water needs and so on. Recent studies have primarily evaluated the schedule ability of dams according to their quantifiable attributes, such as water quantity, flow velocity, etc. However, the ecological and management status can directly determine the possibility and efficiency of a dam's water resource scheduling. This paper presents an evaluation model to assess the scheduling capacity of dams that takes into consideration ecological and management factors. In the experiment stage, this paper takes the Sha Ying river of the Huai He River Basin as an example to evaluate the scheduling ability of its dams. The results indicate that the proposed evaluation model can provide more precise and practical suggestions.

  7. Factors affecting water balance and percolate production for a landfill in operation.

    Science.gov (United States)

    Poulsen, Tjalfe G; Møoldrup, Per

    2005-02-01

    Percolate production and precipitation data for a full-scale landfill in operation measured over a 13-year period were used to evaluate the impact and importance of the hydrological conditions of landfill sections on the percolate production rates. Both active (open) and closed landfill sections were included in the evaluation. A simple top cover model requiring a minimum of input data was used to simulate the percolate production as a function of precipitation and landfill section hydrology. The results showed that changes over time in the hydrology of individual landfill sections (such as section closure or plantation of trees on top of closed sections) can change total landfill percolate production by more than 100%; thus, percolate production at an active landfill can be very different from percolate production at the same landfill after closure. Furthermore, plantation of willow on top of closed sections can increase the evapotranspiration rate thereby reducing percolate production rates by up to 47% compared to a grass cover. This process, however, depends upon the availability of water in the top layer, and so the evaporation rate will be less than optimal during the summer where soil-water contents in the top cover are low.

  8. Criticisms of chlorination: social determinants of drinking water beliefs and practices among the Tz'utujil Maya.

    Science.gov (United States)

    Nagata, Jason M; Valeggia, Claudia R; Smith, Nathaniel W; Barg, Frances K; Guidera, Mamie; Bream, Kent D W

    2011-01-01

    To explore social determinants of drinking water beliefs and practices among the Tz'utujil Maya of Santiago Atitlán, Guatemala, through analysis of demographics, socioeconomic status, memory of historical events, sensory experience, and water attitudes. Parallel mixed (qualitative and quantitative) methods, including participant observation, in-depth interviews based on a purposive sample, and 201 semi-structured interviews based on a regional quota sample, were used to collect data from March 2007 to August 2008. Data analysis included the use of grounded theory methodology and Pearson's chi-square test for independence. Qualitative results based on grounded theory highlighted how memory of the Guatemalan Civil War and Hurricane Stan, attitudes about Lake Atitlán water, and the taste and smell of chlorine influenced Tz'utujil Maya drinking water beliefs. Quantitative survey results revealed that differences in ethnicity, literacy, years of schooling, distrust of the water supply during the Civil War and Hurricane Stan, and current beliefs about Lake Atitlán and tap water quality were associated with significantly different water self-treatment practices. In accordance with social determinants of health paradigms, demographic, socioeconomic, social, cultural, political, and historical factors continue to be significant determinants of water-related health. Public health water interventions must address inequalities related to these underlying factors in order to achieve maximum effectiveness.

  9. Vision in water.

    Science.gov (United States)

    Atchison, David A; Valentine, Emma L; Gibson, Georgina; Thomas, Hannah R; Oh, Sera; Pyo, Young Ah; Lacherez, Philippe; Mathur, Ankit

    2013-09-06

    The purpose of this study is to determine visual performance in water, including the influence of pupil size. The water environment was simulated by placing goggles filled with saline in front of the eyes with apertures placed at the front of the goggles. Correction factors were determined for the different magnification under this condition in order to estimate vision in water. Experiments were conducted on letter visual acuity (seven participants), grating resolution (eight participants), and grating contrast sensitivity (one participant). For letter acuity, mean loss of vision in water, compared to corrected vision in air, varied between 1.1 log min of arc resolution (logMAR) for a 1 mm aperture to 2.2 logMAR for a 7 mm aperture. The vision in min of arc was described well by a linear relationship with pupil size. For grating acuity, mean loss varied between 1.1 logMAR for a 2 mm aperture to 1.2 logMAR for a 6 mm aperture. Contrast sensitivity for a 2 mm aperture deteriorated as spatial frequency increased with a 2 log unit loss by 3 c/°. Superimposed on this deterioration were depressions (notches) in sensitivity with the first three notches occurring at 0.45, 0.8, and 1.3 c/° with estimates for water of 0.39, 0.70, and 1.13 c/°. In conclusion, vision in water is poor. It becomes worse as pupil size increases, but the effects are much more marked for letter targets than for grating targets.

  10. Cold Heat Storage Characteristics of O/W-type Latent Heat Emulsion Including Continuum Phase of Water Treated with a Freezing Point Depression

    Science.gov (United States)

    Inaba, Hideo; Morita, Shin-Ichi

    This paper deals with flow and cold heat storage characteristics of the oil (tetradecane, C14H30, freezing point 278.9 K, Latent heat 229 kJ/kg)/water emulsion as a latent heat storage material having a low melting point. The test emulsion includes a water-urea solution as a continuum phase. The freezing point depression of the continuum phase permits enhancement of the heat transfer rate of the emulison, due to the large temperature difference between the latent heat storage material and water-urea solution. The velocity of emulsion flow and the inlet temperature of coolant in a coiled double tube heat exchanger are chosen as the experimental parameters. The pressure drop, the heat transfer coefficient of the emulsion in the coiled tube are measured in the temperture region over solid and liquid phase of the latent heat storage material. The finishing time of the cold heat storage is defined experimentally in the range of sensible and latent heat storage. It is clarified that the flow behavior of the emulsion as a non-Newtonian fluid has an important role in cold heat storage. The useful nondimentional correlation equations for the additional pressure loss coefficient, the heat transfer coefficient and the finishing time of the cold heat storage are derived in terms of Dean number and heat capacity ratio.

  11. 30 CFR 250.415 - What must my casing and cementing programs include?

    Science.gov (United States)

    2010-07-01

    ... included in API RP 65, Recommended Practice for Cementing Shallow Water Flow Zones in Deep Water Wells... and are in either of the following two areas: (1) An “area with an unknown shallow water flow potential” is a zone or geologic formation where neither the presence nor absence of potential for a shallow...

  12. Water-quality assessment of the New England Coastal Basins in Maine, Massachusetts, New Hampshire, and Rhode Island : environmental settings and implications for water quality and aquatic biota

    Science.gov (United States)

    Flanagan, Sarah M.; Nielsen, Martha G.; Robinson, Keith W.; Coles, James F.

    1999-01-01

    The New England Coastal Basins in Maine, Massachusetts, New Hampshire, and Rhode Island constitute one of 59 study units selected for water-quality assessment as part of the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program. England Coastal Basins study unit encompasses the fresh surface waters and ground waters in a 23,000 square-mile area that drains to the Atlantic Ocean. Major basins include those of the Kennebec, Androscoggin, Saco, Merrimack, Charles, Blackstone, Taunton, and Pawcatuck Rivers. Defining the environmental setting of the study unit is the first step in designing and conducting a multi-disciplinary regional water-quality assessment. The report describes the natural and human factors that affect water quality in the basins and includes descriptions of the physiography, climate, geology, soils, surface- and ground-water hydrology, land use, and the aquatic ecosystem. Although surface-water quality has greatly improved over the past 30 years as a result of improved wastewater treatment at municipal and industrial wastewater facilities, a number of water-quality problems remain. Industrial and municipal wastewater discharges, combined sewer overflows, hydrologic modifications from dams and water diversions, and runoff from urban land use are the major causes of water-quality degradation in 1998. The most frequently detected contaminants in ground water in the study area are volatile organic compounds, petroleum-related products, nitrates, and chloride and sodium. Sources of these contaminants include leaking storage tanks, accidental spills, landfills, road salting, and septic systems and lagoons. Elevated concentrations of mercury are found in fish tissue from streams and lakes throughout the study area.

  13. Evaluation of Water Resources Carrying Capacity in Shandong Province Based on Fuzzy Comprehensive Evaluation

    Directory of Open Access Journals (Sweden)

    Zhao Qiang

    2018-01-01

    Full Text Available Water resources carrying capacity is the maximum available water resources supporting by the social and economic development. Based on investigating and statisticing on the current situation of water resources in Shandong Province, this paper selects 13 factors including per capita water resources, water resources utilization, water supply modulus, rainfall, per capita GDP, population density, per capita water consumption, water consumption per million yuan, The water consumption of industrial output value, the agricultural output value of farmland, the irrigation rate of cultivated land, the water consumption rate of ecological environment and the forest coverage rate were used as the evaluation factors. Then,the fuzzy comprehensive evaluation model was used to analyze the water resources carrying capacity Force status evaluation. The results showed : The comprehensive evaluation results of water resources in Shandong Province were lower than 0.6 in 2001-2009 and higher than 0.6 in 2010-2015, which indicating that the water resources carrying capacity of Shandong Province has been improved.; In addition, most of the years a value of less than 0.6, individual years below 0.4, the interannual changes are relatively large, from that we can see the level of water resources is generally weak, the greater the interannual changes in Shandong Province.

  14. Distribution characteristics of radium isotopes and their influence factors in the water of Jiaozhou Bay area

    International Nuclear Information System (INIS)

    Wang Bo; Guo Zhanrong; Yuan Xiaojie; Zhang Bin; Ma Zhiyong; Liu Jie

    2014-01-01

    Background: The interaction between continental and oceanic process is much intense in coastal region. The terrestrial freshwater mixes with seawater here which leads to the chemical constituents in water undergo rapid change. Purpose: The aim is to analyze and study the distribution characteristics of 224 Ra and 226 Ra and their influence factors in the water of Jiaozhou Bay area. Methods: The water samples of 224 Ra and 226 Ra were collected from groundwater, river water and seawater around the Jiaozhou Bay from April to May, 2012. In the laboratory, the activities of 224 Ra absorbed on the Mn-fiber were measured through the continuous emanation method. Finally, the Mn-fiber was sealed for more than 7 days, and the activities of 226 Ra absorbed on the Mn-fiber were measured through the direct emanation method. Results: The results show that the activities of 224 Ra and 226 Ra in groundwater and river water are much higher in the granitic area which has higher concentration of 232 Th and 238 U. Because of mixing with seawater, the salinity of groundwater and river water in coastal region rises which leads to the increasing amounts of 224 Ra and 226 Ra desorbed from the particles, resulting in higher activities of 224 Ra and 226 Ra in coastal region. Affected by the input of river (dissolved and desorbed from suspended particles) and submarine groundwater discharge (SGD), the activities of 224 Ra and 226 Ra are relatively higher in nearshore seawater, then with the decay of 224 Ra and mixing dilution effect of the offshore seawater, the activities of 224 Ra gradually decrease from nearshore region to the open ocean. The activities of 226 Ra in the seawater of Jiaozhou Bay remain high-level values, and there are only a few zones of low 226 Ra activities. The main reasons are that the activities of 226 Ra from terrestrial freshwater are close to those from offshore seawater and the half-life of 226 Ra is very long. Conclusion: The activities of 224 Ra and 226 Ra in

  15. Water Resources

    International Nuclear Information System (INIS)

    Abira, M.A.

    1997-01-01

    Water is essential for life and ecological sustenance; its availability is essential component of national welfare and productivity.The country's socio-economic activities are largely dependent on the natural endowment of water resources. Kenya's water resources comprises of surface waters (rivers, lakes and wetlands) and ground water. Surface water forms 86% of total water resources while the rest is ground water Geological, topographical and climatic factors influence the natural availability and distribution of water with the rainfall distribution having the major influence. Water resources in Kenya are continuously under threat of depletion and quality degradation owing to rising population, industrialization, changing land use and settlement activities as well as natural changes. However, the anticipated climate change is likely to exacerbate the situation resulting in increased conflict over water use rights in particular, and, natural resource utilisation in general. The impacts of climate change on the water resources would lead to other impacts on environmental and socio-economic systems

  16. Adsorption and Biocirculation in Oceanic Waters

    Energy Technology Data Exchange (ETDEWEB)

    Zenkevich, L. A.

    1960-07-01

    It is generally known that in recent years oceanographers in all countries have denoted great attention to studying the dispersion routes and speed of movement of radioactive decay products in oceanic waters. At the same time the form, degree and extent of contamination of oceanic waters by fission products has been investigated. It is clear that scientists are becoming more and more interested in living organisms as a factor responsible for the transport and distribution of radioactive substances in water. B. Ketchum and Y. Bowen discuss the concept of 'biological transport' and make an interesting attempt to define it in mathematical terms and to collate it with research on 'physical transport'. The term 'biocirculation' has come into use. It is evident that this factor cannot be left out of account as a means of transport or system of adsorption. The great volume of suspension formed of mineral substances and not containing living organisms is characterized by its relatively low mobility, and the bacterial and phytoplankton bodies constitute a vast adsorption surface (Tables 1 and 2). The ocean water column contains a vast quantity of matter in suspension, including living organisms (bacteria, phytoplankton and zooplankton) and components not containing living organisms (bioseston and abioseston). Quantitative determination of all the seston enables its role as an adsorption surface and as a mechanism of vertical and horizontal biocirculation to be evaluated. The adsorption surface for various seston groups in average density distribution zones, and the index of subsurface biocirculation in a water column less than 1 m{sup 2} in the habitat are given.

  17. Effect of beach management policies on recreational water quality.

    Science.gov (United States)

    Kelly, Elizabeth A; Feng, Zhixuan; Gidley, Maribeth L; Sinigalliano, Christopher D; Kumar, Naresh; Donahue, Allison G; Reniers, Adrianus J H M; Solo-Gabriele, Helena M

    2018-04-15

    When beach water monitoring programs identify poor water quality, the causes are frequently unknown. We hypothesize that management policies play an important role in the frequency of fecal indicator bacteria (FIB) exceedances (enterococci and fecal coliform) at recreational beaches. To test this hypothesis we implemented an innovative approach utilizing large amounts of monitoring data (n > 150,000 measurements per FIB) to determine associations between the frequency of contaminant exceedances and beach management practices. The large FIB database was augmented with results from a survey designed to assess management policies for 316 beaches throughout the state of Florida. The FIB and survey data were analyzed using t-tests, ANOVA, factor analysis, and linear regression. Results show that beach geomorphology (beach type) was highly associated with exceedance of regulatory standards. Low enterococci exceedances were associated with open coast beaches (n = 211) that have sparse human densities, no homeless populations, low densities of dogs and birds, bird management policies, low densities of seaweed, beach renourishment, charge access fees, employ lifeguards, without nearby marinas, and those that manage storm water. Factor analysis and a linear regression confirmed beach type as the predominant factor with secondary influences from grooming activities (including seaweed densities and beach renourishment) and beach access (including charging fees, employing lifeguards, and without nearby marinas). Our results were observable primarily because of the very large public FIB database available for analyses; similar approaches can be adopted at other beaches. The findings of this research have important policy implications because the selected beach management practices that were associated with low levels of FIB can be implemented in other parts of the US and around the world to improve recreational beach water quality. Copyright © 2018 Elsevier Ltd. All

  18. IMPROVED PARAMETERIZATION OF WATER CLOUD MODEL FOR HYBRID-POLARIZED BACKSCATTER SIMULATION USING INTERACTION FACTOR

    Directory of Open Access Journals (Sweden)

    S. Chauhan

    2017-07-01

    Full Text Available The prime aim of this study was to assess the potential of semi-empirical water cloud model (WCM in simulating hybrid-polarized SAR backscatter signatures (RH and RV retrieved from RISAT-1 data and integrate the results into a graphical user interface (GUI to facilitate easy comprehension and interpretation. A predominant agricultural wheat growing area was selected in Mathura and Bharatpur districts located in the Indian states of Uttar Pradesh and Rajasthan respectively to carry out the study. The three-date datasets were acquired covering the crucial growth stages of the wheat crop. In synchrony, the fieldwork was organized to measure crop/soil parameters. The RH and RV backscattering coefficient images were extracted from the SAR data for all the three dates. The effect of four combinations of vegetation descriptors (V1 and V2 viz., LAI-LAI, LAI-Plant water content (PWC, Leaf water area index (LWAI-LWAI, and LAI-Interaction factor (IF on the total RH and RV backscatter was analyzed. The results revealed that WCM calibrated with LAI and IF as the two vegetation descriptors simulated the total RH and RV backscatter values with highest R2 of 0.90 and 0.85 while the RMSE was lowest among the other tested models (1.18 and 1.25 dB, respectively. The theoretical considerations and interpretations have been discussed and examined in the paper. The novelty of this work emanates from the fact that it is a first step towards the modeling of hybrid-polarized backscatter data using an accurately parameterized semi-empirical approach.

  19. Heavy metals in drinking water: Occurrences, implications, and future needs in developing countries.

    Science.gov (United States)

    Chowdhury, Shakhawat; Mazumder, M A Jafar; Al-Attas, Omar; Husain, Tahir

    2016-11-01

    Heavy metals in drinking water pose a threat to human health. Populations are exposed to heavy metals primarily through water consumption, but few heavy metals can bioaccumulate in the human body (e.g., in lipids and the gastrointestinal system) and may induce cancer and other risks. To date, few thousand publications have reported various aspects of heavy metals in drinking water, including the types and quantities of metals in drinking water, their sources, factors affecting their concentrations at exposure points, human exposure, potential risks, and their removal from drinking water. Many developing countries are faced with the challenge of reducing human exposure to heavy metals, mainly due to their limited economic capacities to use advanced technologies for heavy metal removal. This paper aims to review the state of research on heavy metals in drinking water in developing countries; understand their types and variability, sources, exposure, possible health effects, and removal; and analyze the factors contributing to heavy metals in drinking water. This study identifies the current challenges in developing countries, and future research needs to reduce the levels of heavy metals in drinking water. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Formation waters of the Norwegian Continental Shelf

    Energy Technology Data Exchange (ETDEWEB)

    McCartney, R. A.; Rein, E.

    2006-03-15

    New and previously published analyses of formation waters for the Norwegian Continental Shelf (NCS) have been evaluated and interpreted to determine the compositional distribution of formation waters in the region and factors controlling their compositions, and also to obtain information on subsurface fluid flow. Formation waters in the region are Na-Cl and Na-Ca-Cl-type waters that display a wide range of salinity (2500-212000 mg/kg Cl). Generally, the concentrations of most dissolved constituents are positively correlated with Cl so that their distribution in formation waters largely reflects the variations shown by salinity. Exceptions are SO4 which is generally low (less than 40 mg/l) regardless of Cl, and HCO3 and in-situ pH which are negatively correlated with Cl. The main factors determining the compositions of the formation waters are mixing of meteoric water (probably late-Jurassic to Eocene), ancient seawater and primary brine together with diagenetic reactions that have affected each of these components individually as well as mixtures of them. Evaluation of the distribution of salinity has helped us identify where vertical and/or lateral migration of brine from the evaporites has occurred. This has in turn provided us with information on the presence of leak-points and vertical mixing, although further investigation of the location of evaporites and basin palaeohydrogeology are required to determine whether regional lateral advection has occurred in the past. The results of this study may benefit oil exploration and production activities in the NCS including constraint of hydrocarbon migration models, economic evaluation of undrilled prospects, scale management and compartmentalisation studies. (Author)

  1. Environmental Setting and Implications on Water Quality, Upper Colorado River Basin, Colorado and Utah

    Science.gov (United States)

    Apodaca, Lori E.; Driver, Nancy E.; Stephens, Verlin C.; Spahr, Norman E.

    1995-01-01

    The Upper Colorado River Basin in Colorado and Utah is 1 of 60 study units selected for water-quality assessment as part of the U.S. Geological Survey's National Water-Quality Assessment program, which began full implementation in 1991. Understanding the environmental setting of the Upper Colorado River Basin study unit is important in evaluating water-quality issues in the basin. Natural and human factors that affect water quality in the basin are presented, including an overview of the physiography, climatic conditions, general geology and soils, ecoregions, population, land use, water management and use, hydrologic characteristics, and to the extent possible aquatic biology. These factors have substantial implications on water-quality conditions in the basin. For example, high concentrations of dissolved solids and selenium are present in the natural background water conditions of surface and ground water in parts ofthe basin. In addition, mining, urban, and agricultural land and water uses result in the presence of certain constituents in the surface and ground water of the basin that can detrimentally affect water quality. The environmental setting of the study unit provides a framework of the basin characteristics, which is important in the design of integrated studies of surface water, ground water, and biology.

  2. Meta-regression analysis of commensal and pathogenic Escherichia coli survival in soil and water.

    Science.gov (United States)

    Franz, Eelco; Schijven, Jack; de Roda Husman, Ana Maria; Blaak, Hetty

    2014-06-17

    The extent to which pathogenic and commensal E. coli (respectively PEC and CEC) can survive, and which factors predominantly determine the rate of decline, are crucial issues from a public health point of view. The goal of this study was to provide a quantitative summary of the variability in E. coli survival in soil and water over a broad range of individual studies and to identify the most important sources of variability. To that end, a meta-regression analysis on available literature data was conducted. The considerable variation in reported decline rates indicated that the persistence of E. coli is not easily predictable. The meta-analysis demonstrated that for soil and water, the type of experiment (laboratory or field), the matrix subtype (type of water and soil), and temperature were the main factors included in the regression analysis. A higher average decline rate in soil of PEC compared with CEC was observed. The regression models explained at best 57% of the variation in decline rate in soil and 41% of the variation in decline rate in water. This indicates that additional factors, not included in the current meta-regression analysis, are of importance but rarely reported. More complete reporting of experimental conditions may allow future inference on the global effects of these variables on the decline rate of E. coli.

  3. [HYGIENIC JUSTIFICATION OF OPTIMIZATION OF THE INTEGRATED ASSESSMENT OF DRINKING WATER ACCORDING TO THE WATER QUALITY INDEX].

    Science.gov (United States)

    Krasovskiy, G N; Rakhmanin, Yu; Egorova, N

    2015-01-01

    The present study is devoted to theoretical questions of optimization of integrated assessment of the composition and properties of drinking water with the use of the Water Quality Index (WQI) and considering in it all 4 criteria for its hygienic quality-sanitary-toxicological, microbiological, radiation and organoleptic. There is presented a sequence of the analysis of benchmark data of the laboratory study of drinking water, including the selection of priority indices, their distribution into 4 groups according to hygienic criteria, calculations the ratios of real values (C) of indices to their hygiene MPC and the final calculation of the WQI. There is emphasized the importance of classes of hazard of substances, and the need for the special attention to the substances-carcinogens in the integrated assessment of water quality. To overcome the non-equivalence of contributions to the assessment of water quality factors, measured in different units, often disparated in their effect on human health, there are used the principles of combined action at levels below the MCL:C/MPC indices of performance of the unidirectional action are summed (e.g. carcinogenic substances), from indices of the independent action there are selected the most significant ones with the highest values of C/MPC, besides that there are also used counterbalancing factors K determined accordingly to Delphi method, with a maximum values of 5 for carcinogens and the minimum value of 1 for the substances affecting the organoleptic properties ofwater. There is presented the scheme of the final calculation of the value of WQI.

  4. A review on risk assessment techniques for hydraulic fracturing water and produced water management implemented in onshore unconventional oil and gas production.

    Science.gov (United States)

    Torres, Luisa; Yadav, Om Prakash; Khan, Eakalak

    2016-01-01

    The objective of this paper is to review different risk assessment techniques applicable to onshore unconventional oil and gas production to determine the risks to water quantity and quality associated with hydraulic fracturing and produced water management. Water resources could be at risk without proper management of water, chemicals, and produced water. Previous risk assessments in the oil and gas industry were performed from an engineering perspective leaving aside important social factors. Different risk assessment methods and techniques are reviewed and summarized to select the most appropriate one to perform a holistic and integrated analysis of risks at every stage of the water life cycle. Constraints to performing risk assessment are identified including gaps in databases, which require more advanced techniques such as modeling. Discussions on each risk associated with water and produced water management, mitigation strategies, and future research direction are presented. Further research on risks in onshore unconventional oil and gas will benefit not only the U.S. but also other countries with shale oil and gas resources. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Managing the urban water-energy nexus

    Science.gov (United States)

    Escriva-Bou, Alvar; Pulido-Velazquez, Manuel; Lund, Jay R.

    2016-04-01

    Water use directly causes a significant amount of energy use in cities. In this paper we assess energy and greenhouse emissions related with each part of the urban water cycle and the consequences of several changes in residential water use for customers, water and energy utilities, and the environment. First, we develop an hourly model of urban water uses by customer category including water-related energy consumption. Next, using real data from East Bay Municipal Utility District in California, we calibrate a model of the energy used in water supply, treatment, pumping and wastewater treatment by the utility. Then, using data from the California Independent System Operator, we obtain hourly costs of energy for the energy utility. Finally, and using emission factors reported by the energy utilities we estimate greenhouse gas emissions for the entire urban water cycle. Results of the business-as-usual scenario show that water end uses account for almost 95% of all water-related energy use, but the 5% managed by the utility is still worth over 12 million annually. Several simulations analyze the potential benefits for water demand management actions showing that moving some water end-uses from peak to off-peak hours such as outdoor use, dishwasher or clothes washer use have large benefits for water and energy utilities, especially for locations with a high proportion of electric water heaters. Other interesting result is that under the current energy rate structures with low or no fixed charges, energy utilities burden most of the cost of the conservation actions.

  6. Vegetation type and the presence of ash as factors in the evolution of soil water repellency after a forest fire

    Directory of Open Access Journals (Sweden)

    P. Jiménez-Pinilla

    2013-05-01

    Full Text Available After wildfires, burning may induce the occurrence of soil water repellency. Soil water repellency may vary in space and time in function of vegetation, the presence of ash and soil moisture. This study analyzes the evolution of fire-induced soil water repellency in function of these factors, and proposes measures to promote the restoration of fire-affected soils. Burnt and unburnt (control soil plots under pine and shrub from a recently burned area (Gorga, Alicante, SE Spain were established. Three treatments were applied: in some of the plots, the original ash layer was kept on the ground; in a second group, the ash layer was removed for simulating the effects of erosion; finally, in a third group, percolating irrigation was conducted to simulate a possible good input of water into the soil profile after burning, that could occur if the first rains were with high quantity but low intensity. During the dry season, soil moisture content was significantly lower in burned plots due to fire-induced water repellency and reduced vegetation cover. During the wet season, soil moisture decreased in the control unburnt plots due to direct evaporation of water intercepted by vegetation and consumption by roots. Fire increased soil water repellency only in plots under pine. Water repellency decreased during the wet season, disappearing in January and reappearing after declining rainfalls. This baseline recovery of soil water repellency was lower where ash removal was simulated. In unburned plots, seasonal fluctuations were less important. In general, ash removal promotes a rapid reduction of water repellency, since it can induce washing of hydrophobic compounds. Irrigation performed immediately after the fire also contributed to decreased water repellency.

  7. Water Quality Monitoring of Inland Waters using Meris data

    Science.gov (United States)

    Potes, M.; Costa, M. J.; Salgado, R.; Le Moigne, P.

    2012-04-01

    The successful launch of ENVISAT in March 2002 has given a great opportunity to understand the optical changes of water surfaces, including inland waters such as lakes and reservoirs, through the use of the Medium Resolution Imaging Spectrometer (MERIS). The potential of this instrument to describe variations of optically active substances has been examined in the Alqueva reservoir, located in the south of Portugal, where satellite spectral radiances are corrected for the atmospheric effects to obtain the surface spectral reflectance. In order to validate this spectral reflectance, several field campaigns were carried out, with a portable spectroradiometer, during the satellite overpass. The retrieved lake surface spectral reflectance was combined with limnological laboratory data and with the resulting algorithms, spatial maps of biological quantities and turbidity were obtained, allowing for the monitoring of these water quality indicators. In the framework of the recent THAUMEX 2011 field campaign performed in Thau lagoon (southeast of France) in-water radiation, surface irradiation and reflectance measurements were taken with a portable spectrometer in order to test the methodology described above. At the same time, water samples were collected for laboratory analysis. The two cases present different results related to the geographic position, water composition, environment, resources exploration, etc. Acknowledgements This work is financed through FCT grant SFRH/BD/45577/2008 and through FEDER (Programa Operacional Factores de Competitividade - COMPETE) and National funding through FCT - Fundação para a Ciência e a Tecnologia in the framework of projects FCOMP-01-0124-FEDER-007122 (PTDC / CTE-ATM / 65307 / 2006) and FCOMP-01-0124-FEDER-009303 (PTDC/CTE-ATM/102142/2008). Image data has been provided by ESA in the frame of ENVISAT projects AOPT-2423 and AOPT-2357. We thank AERONET investigators for their effort in establishing and maintaining Évora AERONET

  8. Factors that contribute to biomarker responses in humans including a study in individuals taking Vitamin C supplementation.

    Science.gov (United States)

    Anderson, D

    2001-09-01

    It is possible in many situations to identify humans exposed to potentially toxic materials in the workplace and in the environment. As in most human studies, there tends to be a high degree of interindividual variability in response to chemical insults. Some non-exposed control individuals exhibit as high a level of damage as some exposed individuals and some of these have levels of damage as low as many of the controls. Thus, it is only the mean values of the groups that can substantiate an exposure-related problem; the data on an individual basis are still of limited use. While human lymphocytes remain the most popular cell type for monitoring purposes, sperm, buccal, nasal, epithelial and placental cells are also used. However, for interpretation of responses, the issue of confounding factors must be addressed. There are endogenous confounding factors, such as age, gender, and genetic make-up and exogenous ones, including lifestyle habits (smoking, drinking, etc.) There are biomarkers of exposure, effect/response and susceptibility and the last may be influenced by the genotype and polymorphism genes existing in a population. From our own studies, confounding effects on cytogenetic damage and ras oncoproteins will be considered in relation to workers exposed to vinyl chloride and petroleum emissions and to volunteers taking Vitamin C supplementation. Smoking history, exposure and duration of employment affected the worker studies. For petroleum emissions, so did gender and season of exposure. For the non-smoking volunteer Vitamin C supplementation study, cholesterol levels, plasma Vitamin C levels, lipid peroxidation products and DNA damage in the Comet assay were also measured. Gender affected differences in Vitamin C levels, antioxidant capacity and the number of chromosome aberrations induced by bleomycin challenge in vitro. The results were the same for both high and low cholesterol subjects. The relationship between biomarkers and the various factors which

  9. The recycling of domestic waste water. A study of the factors influencing the storage capacity and the simulation of the usage patterns

    Energy Technology Data Exchange (ETDEWEB)

    Fewkes, A; Ferris, S A

    1982-01-01

    The flushing of toilets with recycled domestic waste water makes a significant saving in the use of potable water. The size of the storage tank is a critical factor in the design of such a system; the inputs to the storage, which are random, are influenced by the size of family and individual washing and bathing habits. The demand from the storage tank is random in time but the volume is constant at each occurrence. A method of generating these waste water time series, with their inherent stochastic nature, is described. These simulated event patterns are then used to investigate the operation of a single-tank waste water storage system. The computer model determines the percentage of water conserved for several combinations of storage capacity and family size: the effect of changes in design parameters and operating conditions on the system performance is also assessed.

  10. N-nitrosodimethylamine in drinking water using a rapid, solid-phase extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S W.D. [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Koester, C J [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Taguchi, V Y [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Wang, D T [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Palmentier, J P.F.P. [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Hong, K P [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch

    1995-12-01

    A simple, rapid method for the extraction of N-nitrosodimethylamine (NDMA) from drinking and surface waters was developed using Ambersorb 572. Development of an alternative method to classical liquid-liquid extraction techniques was necessary to handle the workload presented by implementation of a provincial guideline of 9 ppt for drinking water and a regulatory level of 200 ppt for effluents. A granular absorbent, Ambersorb 572, was used to extract the NDMA from the water in the sample bottle. The NDMA was extracted from the Ambersorb 572 with dichloromethane in the autosampler vial. Method characteristics include a precision of 4% for replicate analyses, and accuracy of 6% at 10 ppt and a detection limit of 1.0 ppt NDMA in water. Comparative data between the Ambersorb 572 method and liquid-liquid extraction showed excellent agreement (average difference of 12%). With the Ambersorb 572 method, dichloromethane use has been reduced by a factor of 1,000 and productivity has been increased by a factor of 3-4. Monitoring of a drinking water supply showed rapidly changing concentrations of NDMA from day to day. (orig.)

  11. Biofilm human consumption water distribution systems; El biofilm en sistemas de distribuciond e aguas de consumo humano

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A.; Pedreira, S.

    2003-07-01

    A study was carried out of the presence of biofilm in the water distribution conduits in urban supply systems, as it raises health, water quality and corrosion issues. In order to take appropriate measures to control the presence of biofilm, it is first necessary to know what it, is how it is formed and the factors that influence its development. its structure includes both microbial cells and biopolymers that make up a protective structure. The most common micro-organisms are usually heterotrophic bacteria, that is bacteria requiring organic carbon in ore to grow. They may also occasionally include fungus, protozoa and algae, though to a lesser degree. Definitions are provided of the factors influencing the growth of biofilm, preventive measures and detection in water supply systems and solutions are put forward for dealing with it once it has appeared. (Author)

  12. Correlations between water-soluble organic aerosol and water vapor: a synergistic effect from biogenic emissions?

    Science.gov (United States)

    Hennigan, Christopher J; Bergin, Michael H; Weber, Rodney J

    2008-12-15

    Ground-based measurements of meteorological parameters and water-soluble organic carbon in the gas(WSOCg) and particle (WSOCp) phases were carried out in Atlanta, Georgia, from May to September 2007. Fourteen separate events were observed throughout the summer in which WSOCp and water vapor concentrations were highly correlated (average WSOCp-water vapor r = 0.92); however, for the entire summer, no well-defined relationship existed between the two. The correlation events, which lasted on average 19 h, were characterized by a wide range of WSOCp and water vapor concentrations. Several hypotheses for the correlation are explored, including heterogeneous liquid phase SOA formation and the co-emission of biogenic VOCs and water vapor. The data provide supporting evidence for contributions from both and suggest the possibility of a synergistic effect between the co-emission of water vapor and VOCs from biogenic sources on SOA formation. Median WSOCp concentrations were also correlated with elemental carbon (EC), although this correlation extended over the entire summer. Despite the emission of water vapor from anthropogenic mobile sources and the WSOCp-EC correlation, mobile sources were not considered a potential cause for the WSOCp-water vapor correlations because of their low contribution to the water vapor budget. Meteorology could perhaps have influenced the WSOCp-EC correlation, but other factors are implicated as well. Overall, the results suggest that the temperature-dependent co-emission of water vapor through evapotranspiration and SOA precursor-VOCs by vegetation may be an important process contributing to SOA in some environments.

  13. Environmental radioactivity in the North Atlantic region including the Faroe Islands and Greenland

    International Nuclear Information System (INIS)

    Aarkrog, A.; Chen, Q.J.; Dahlgaard, H.; Hansen, H.; Nielsen, S.P.; Buch, E.; Christensen, G.C.; Holm, E.

    1992-01-01

    Measurements of fallout radioactivity in the North Atlantic region including the Faroe Islands and Greenland are reported. Strontium-90, cesium-137 and cesium-134 were determined in samples of precipitation, sea water, vegetation, various foodstuffs (including milk in the Faroes), and drinking water. Estimates are given of the mean contents of 90 Sr and 137 Cs in human diet in the Faroes and Greenland in 1988 and 1989. 99 Tc data on marine samples, in particular sea water from the Greenland Sea, are reported. (au) (91 taps., 51 ills., 7 refs.)

  14. Hydrochemistry and coal mining activity induced karst water quality degradation in the Niangziguan karst water system, China.

    Science.gov (United States)

    Zhang, Xiaobo; Li, Xue; Gao, Xubo

    2016-04-01

    Hydrogeochemical analysis, statistical analysis, and geochemical modeling were employed to evaluate the impacts of coal mining activities on karst water chemistry in Niangziguan spring catchment, one of the largest karst springs in Northern China. Significant water quality deterioration was observed along the flow path, evidenced from the increasing sulfate, nitrate, and TDS content in karst water. Karst water samples are Ca-Mg-HCO3 type in the recharge areas, Ca-Mg-HCO3-SO4 type in the coal mining areas, and Ca-Mg-SO4-HCO3/HCO3-SO4 type in the rural areas and discharge areas. A four-factor principal component analysis (PCA) model is conducted which explains over 82.9% of the total variation. Factor 1, which explained the largest portion (45.33%) of the total variance, reveals that coal mining activities and natural water-rock interaction as the primary factors controlling karst water quality. Anthropogenic effects were recognized as the secondary factor with high positive loadings for NO3 (-) and Cl(-) in the model. The other two factors are co-precipitation removal of trace elements and silicate mineral dissolution, which explained 20.96% of the total variance. A two-end mixing modeling was proposed to estimate the percentage of coal wastewater giving on karst water chemistry, based on the groundwater sulfate chemistry constrains rather than sulfur isotopes. Uncertainty of sulfur isotope sources led to an overestimation of coal mining water contribution. According to the results of the modeling, the contribution of coal mining waste on karst water chemistry was quantified to be from 27.05 to 1.11% which is ca. three times lower than the values suggested using a sulfur isotope method.

  15. Water

    International Nuclear Information System (INIS)

    Chovanec, A.; Grath, J.; Kralik, M.; Vogel, W.

    2002-01-01

    An up-date overview of the situation of the Austrian waters is given by analyzing the status of the water quality (groundwater, surface waters) and water protection measures. Maps containing information of nitrate and atrazine in groundwaters (analyses at monitoring stations), nitrate contents and biological water quality of running waters are included. Finally, pollutants (nitrate, orthophosphate, ammonium, nitrite, atrazine etc.) trends in annual mean values and median values for the whole country for the years 1992-1999 are presented in tables. Figs. 5. (nevyjel)

  16. Transfer factors of radionuclides and elements in the terrestrial and fresh water environment of India

    International Nuclear Information System (INIS)

    Hegde, A.G.; Hemalatha, P.; Desai, M.V.M.

    2004-04-01

    This document presents the transfer factor values such as Bioaccumulation factors B p , Transfer coefficient K d , Soil to plant transfer coefficient B v etc. generated in the terrestrial and fresh water environmental matrices of India. This attempt is made with a view to provide site and species specific values in comparison with IAEA default values from Safety Series(SS) No.57 and IAEA Technical Report Series (TRS) No.364. Our recommended B p values for 137 Cs and 90 Sr are matching well with IAEA reported values. B p value for 228 Ra also match well with IAEA values. While the freshwater sediment K d values for 137 Cs is 5000 which is closer to TRS 364 value, 90 Sr K d value is lower than IAEA value. Natural radionuclides Ra, Th and U values are also found to be higher than IAEA values which indicates the site specificity. B p values for stable elements such as Cu, Pb, Mn and Cd are comparable with IAEA whereas the recommended K d value for Zn is higher than IAEA reported value. Transfer factors for cereals, pulses and vegetables are also tabulated in this report in comparison with IAEA reported values. (author)

  17. Inclusion of climatic and touristic factors in the analysis and modelling of the municipal water demand in a Mediterranean region

    Science.gov (United States)

    Toth, Elena; Bragalli, Cristiana; Neri, Mattia

    2017-04-01

    In Mediterranean regions, inherently affected by water scarcity conditions, the gap between water availability and demand may further increase in the near future due to both climatic and anthropogenic drivers. In particular, the high degree of urbanization and the concentration of population and activities in coastal areas is often severely impacting the water availability also for the residential sector. It is therefore crucial analysing the importance of both climatic and touristic factors as drivers for the water demand in such areas, to better understand and model the expected consumption in order to improve the water management policies and practices. The study presents an analysis referred to a large number of municipalities, covering almost the whole Romagna region, in Northern Italy, representing one of the most economically developed areas in Europe and characterized by an extremely profitable tourist industry, especially in the coastal cities. For this region it is therefore extremely important to assess the significance of the drivers that may influence the demand in the different periods of the year, that is climatic factors (rainfall depths and occurrence, temperature averages and extremes), but also the presence of tourists, in both official tourist accommodation structures and in holidays homes (and the latter are very difficult to estimate). Analyses on the Italian water industry at seasonal or monthly time scale has been so far, extremely limited in the literature by the scarce availability of data on the water demands, that are made public only as annual volumes. All the study municipalities are supplied by the same water company, who provided monthly consumption volumes data at the main inlet points of the entire distribution network for a period of 7 years (2009-2015). For the same period, precipitation and temperature data have been collected and summarised in indexes representing monthly averages, days of occurrence and over threshold values

  18. Evaluation of Membrane Ultrafiltration and Residual Chlorination as a Decentralized Water Treatment Strategy for Ten Rural Healthcare Facilities in Rwanda

    Directory of Open Access Journals (Sweden)

    Alexandra Huttinger

    2015-10-01

    Full Text Available There is a critical need for safe water in healthcare facilities (HCF in low-income countries. HCF rely on water supplies that may require additional on-site treatment, and need sustainable technologies that can deliver sufficient quantities of water. Water treatment systems (WTS that utilize ultrafiltration membranes for water treatment can be a useful technology in low-income countries, but studies have not systematically examined the feasibility of this technology in low-income settings. We monitored 22 months of operation of 10 WTS, including pre-filtration, membrane ultrafiltration, and chlorine residual disinfection that were donated to and operated by rural HCF in Rwanda. The systems were fully operational for 74% of the observation period. The most frequent reasons for interruption were water shortage (8% and failure of the chlorination mechanism (7%. When systems were operational, 98% of water samples collected from the HCF taps met World Health Organization (WHO guidelines for microbiological water quality. Water quality deteriorated during treatment interruptions and when water was stored in containers. Sustained performance of the systems depended primarily on organizational factors: the ability of the HCF technician to perform routine servicing and repairs, and environmental factors: water and power availability and procurement of materials, including chlorine and replacement parts in Rwanda.

  19. Water Collection from Air Humidity in Bahrain

    Directory of Open Access Journals (Sweden)

    Dahman. Nidal A.

    2017-01-01

    Full Text Available The Kingdom of Bahrain falls geographically in one of the driest regions in the world. Conventional fresh surface water bodies, such as rivers and lakes, are nonexistent and for water consumption, Bahrain prominently relies on the desalination of sea water. This paper presents an ongoing project that is being pursued by a group of student and their advising professors to investigate the viability of extracting water from air humidity. Dehumidifiers have been utilized as water extraction devices. Those devices have been distributed on six areas that were selected based on a rigorous geospatial modeling of historical meteorological data. The areas fall in residential and industrial neighborhoods that are located in the main island and the island of Muharraq. Water samples have been collected three times every week since May of 2016 and the collection process will continue until May of 2017. The collected water samples have been analyzed against numerous variables individually and in combinations including: amount of water collected per hour versus geographical location, amount of water collected per hour versus meteorological factors, suitability of collected water for potable human consumption, detection of air pollution in the areas of collection and the economy of this method of water collection in comparison to other nonconventional methods. An overview of the completed analysis results is presented in this paper.

  20. Water, food and markets : household-level impact of irrigation water policies and institutions in northern China

    NARCIS (Netherlands)

    Zhang, L.

    2013-01-01

    Water is increasingly becoming a limiting factor for sustainable economic growth and development, particularly in developing countries. Besides technical innovations, water institution reforms may contribute to improving water allocation decisions. Appropriately designed water