WorldWideScience

Sample records for factor loadings ranging

  1. Effect of Water Vapor Pressure on Fatigue Crack Growth in Al-Zn-Cu-Mg Alloy Over Wide-Range Stress Intensity Factor Loading

    Science.gov (United States)

    2014-05-07

    pressure and frequency on fatigue behaviour in 7017-T651 aluminium alloy plate, Acta Mater, 45 (1997) 281-293. [30) N.J.H. Holroyd, D. Hardie, Factors... aluminium alloys , Acta Mater, 45 (1997) 3855-3870. [33) S. Lynch, Hydrogen embrittlement phenomena and mechanisms, Corros Rev, 30 (2012) 105-123. [34...role of environmental exposure in the fatigue behaviour of an aluminium alloy , Corros Sci, 39 (1997) 2117-2141. [39) R.S. Piascik, R.P. Gangloff

  2. Dynamical load factor of impact loaded shell structures

    International Nuclear Information System (INIS)

    Hammel, J.

    1977-01-01

    Dynamical loaded structures can be analysed by spectral representations, which usually lead to an enormous computational effort. If it is possible to find a fitting dynamical load factor, the dynamical problem can be reduced to a statical one. The computation of this statical problem is much simpler. The disadvantage is that the dynamical load factor usually leads to a very rough approximation. In this paper it will be shown, that by combination of these two methods, the approximation of the dynamical load factor can be improved and the consumption of computation time can be enormously reduced. (Auth.)

  3. Assessment of helminth load in faecal samples of free range ...

    African Journals Online (AJOL)

    Helminths load in faecal sample of free range indigenous chicken in Port Harcourt Metropolis was examined. Faecal samples were collected from 224 birds in 15 homesteads and 4 major markets - Mile 3, Mile 1, Borokiri and Eneka Village market where poultry birds are gathered for sale. 0.2-0.5g of feacal sample was ...

  4. Load factors to end March 1989

    International Nuclear Information System (INIS)

    Howles, L.

    1989-01-01

    Load factors for nuclear reactors of 150MWe gross and above for the 12 month period up to the end of March 1989, and over their lifetimes, are tabulated. Units which have been in operation for more than one year as of end March 1989 are ranked in order of annual load factor; cumulative load factors are also shown, measured from first synchronization to the grid not from start of commercial operation. New reactors which had operated for less than 12 months as of end of March 1989 are listed separately. With the exception of the four Paks units in Hungary, Comecon reactors are excluded due to lack of data. (author)

  5. Factor structure underlying components of allostatic load.

    Directory of Open Access Journals (Sweden)

    Jeanne M McCaffery

    Full Text Available Allostatic load is a commonly used metric of health risk based on the hypothesis that recurrent exposure to environmental demands (e.g., stress engenders a progressive dysregulation of multiple physiological systems. Prominent indicators of response to environmental challenges, such as stress-related hormones, sympatho-vagal balance, or inflammatory cytokines, comprise primary allostatic mediators. Secondary mediators reflect ensuing biological alterations that accumulate over time and confer risk for clinical disease but overlap substantially with a second metric of health risk, the metabolic syndrome. Whether allostatic load mediators covary and thus warrant treatment as a unitary construct remains to be established and, in particular, the relation of allostatic load parameters to the metabolic syndrome requires elucidation. Here, we employ confirmatory factor analysis to test: 1 whether a single common factor underlies variation in physiological systems associated with allostatic load; and 2 whether allostatic load parameters continue to load on a single common factor if a second factor representing the metabolic syndrome is also modeled. Participants were 645 adults from Allegheny County, PA (30-54 years old, 82% non-Hispanic white, 52% female who were free of confounding medications. Model fitting supported a single, second-order factor underlying variance in the allostatic load components available in this study (metabolic, inflammatory and vagal measures. Further, this common factor reflecting covariation among allostatic load components persisted when a latent factor representing metabolic syndrome facets was conjointly modeled. Overall, this study provides novel evidence that the modeled allostatic load components do share common variance as hypothesized. Moreover, the common variance suggests the existence of statistical coherence above and beyond that attributable to the metabolic syndrome.

  6. Impact of measurement uncertainty from experimental load distribution factors on bridge load rating

    Science.gov (United States)

    Gangone, Michael V.; Whelan, Matthew J.

    2018-03-01

    Load rating and testing of highway bridges is important in determining the capacity of the structure. Experimental load rating utilizes strain transducers placed at critical locations of the superstructure to measure normal strains. These strains are then used in computing diagnostic performance measures (neutral axis of bending, load distribution factor) and ultimately a load rating. However, it has been shown that experimentally obtained strain measurements contain uncertainties associated with the accuracy and precision of the sensor and sensing system. These uncertainties propagate through to the diagnostic indicators that in turn transmit into the load rating calculation. This paper will analyze the effect that measurement uncertainties have on the experimental load rating results of a 3 span multi-girder/stringer steel and concrete bridge. The focus of this paper will be limited to the uncertainty associated with the experimental distribution factor estimate. For the testing discussed, strain readings were gathered at the midspan of each span of both exterior girders and the center girder. Test vehicles of known weight were positioned at specified locations on each span to generate maximum strain response for each of the five girders. The strain uncertainties were used in conjunction with a propagation formula developed by the authors to determine the standard uncertainty in the distribution factor estimates. This distribution factor uncertainty is then introduced into the load rating computation to determine the possible range of the load rating. The results show the importance of understanding measurement uncertainty in experimental load testing.

  7. An alternative method for centrifugal compressor loading factor modelling

    Science.gov (United States)

    Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.

    2017-08-01

    The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.

  8. 14 CFR 27.337 - Limit maneuvering load factor.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 27.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...

  9. 14 CFR 29.337 - Limit maneuvering load factor.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 29.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...

  10. Common long-range dependence in a panel of hourly Nord Pool electricity prices and loads

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre; Haldrup, Niels; Rodríguez-Caballero, Carlos Vladimir

    to strong seasonal periodicity, and along the cross-sectional dimension, i.e. the hours of the day, there is a strong dependence which necessarily has to be accounted for in order to avoid spurious inference when focusing on the time series dependence alone. The long-range dependence is modelled in terms...... of a fractionally integrated panel data model and it is shown that both prices and loads consist of common factors with long memory and with loadings that vary considerably during the day. Due to the competitiveness of the Nordic power market the aggregate supply curve approximates well the marginal costs...... data approaches to analyse the time series and the cross-sectional dependence of hourly Nord Pool electricity spot prices and loads for the period 2000-2013. Hourly electricity prices and loads data are characterized by strong serial long-range dependence in the time series dimension in addition...

  11. 14 CFR 31.23 - Flight load factor.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...

  12. Conservative flight with a varying load factor and closed form ...

    Indian Academy of Sciences (India)

    Conservative flight performance of an aircraft with constant load factor was analysed by ... Within the frame work of flat earth hypotheses the equations of motion of an aircraft as obtained by ..... load factor function if this inequality holds good.

  13. 14 CFR 398.9 - Load factor standards.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Load factor standards. 398.9 Section 398.9... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.9 Load factor standards. The load factor standards used in this part may be raised for individual eligible places under...

  14. Probability based load factors for design of concrete containment structures

    International Nuclear Information System (INIS)

    Hwang, H.; Kagami, S.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper describes a procedure for developing probability-based load combinations for the design of concrete containments. The proposed criteria are in a load and resistance factor design (LRFD) format. The load factors and resistance factors are derived for use in limit states design and are based on a target limit state probability. In this paper, the load factors for accident pressure and safe shutdown earthquake are derived for three target limit state probabilities. Other load factors are recommended on the basis of prior experience with probability-based design criteria for ordinary building construction. 6 refs

  15. An Optimized Control for LLC Resonant Converter with Wide Load Range

    Science.gov (United States)

    Xi, Xia; Qian, Qinsong

    2017-05-01

    This paper presents an optimized control which makes LLC resonant converters operate with a wider load range and provides good closed-loop performance. The proposed control employs two paralleled digital compensations to guarantee the good closed-loop performance in a wide load range during the steady state, an optimized trajectory control will take over to change the gate-driving signals immediately at the load transients. Finally, the proposed control has been implemented and tested on a 150W 200kHz 400V/24V LLC resonant converter and the result validates the proposed method.

  16. Testing for time-varying loadings in dynamic factor models

    DEFF Research Database (Denmark)

    Mikkelsen, Jakob Guldbæk

    Abstract: In this paper we develop a test for time-varying factor loadings in factor models. The test is simple to compute and is constructed from estimated factors and residuals using the principal components estimator. The hypothesis is tested by regressing the squared residuals on the squared...... there is evidence of time-varying loadings on the risk factors underlying portfolio returns for around 80% of the portfolios....

  17. Load factor trends in light water reactor units

    International Nuclear Information System (INIS)

    Lehtinen, E.A.

    1990-01-01

    The Technical Research Centre of Finland follows up and analyses nuclear power plant availability performances worldwide. The results of a trend study for the load factors of the LWR units have been updated to the end of 1987. The whole operating history, in the sense of the annual and cumulative load factors achieved by all the Western commercial LWR units until the end of 1987, has been taken into consideration. Some trends in the load factors have been identified by using an exponential regression model developed. The LWR units form quite an inhomogeneous population with respect to their age, technical characteristics, site country as well as cumulative load factors achieved. The cumulative load factors achieved by all the LWR units until the end of 1987 are presented individually in the scattergrams

  18. Perceptual load corresponds with factors known to influence visual search.

    Science.gov (United States)

    Roper, Zachary J J; Cosman, Joshua D; Vecera, Shaun P

    2013-10-01

    One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a noncircular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spillover to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. We conclude that rather than be arbitrarily defined, perceptual load might be defined by well-characterized, continuous factors that influence visual search. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  19. Residential Load Manageability Factor Analyses by Load Sensitivity Affected by Temperature

    Directory of Open Access Journals (Sweden)

    N. Eskandari

    2016-12-01

    Full Text Available Load side management is the basic and significant principle to keeping the balance between generation side and consumption side of electrical power energy. Load side management on typical medium voltage feeder is the power energy consumption control of connected loads with variation of essential parameters that loads do reaction to their variation. Knowing amount of load's reaction to each parameters variation in typical medium voltage feeder during the day, leads to gain Load Manageability Factor (LMF for that specific feeder that helps power utilities to manage their connected loads. Calculating this LMF needs to find out each types of load with unique inherent features behavior to each parameters variation. This paper results and future work results will help us to catch mentioned LMF. In this paper analysis of residential load behavior due to temperature variation with training artificial neural network will be done. Load behavior due to other essential parameters variations like energy pricing variation, major event happening, and power utility announcing to the customers, and etc will study in future works. Collecting all related works results in a unit mathematical equation or an artificial neural network will gain LMF.

  20. Loading factor and inclination parameter of diagonal type MHD generators

    International Nuclear Information System (INIS)

    Ishikawa, Motoo

    1979-01-01

    Regarding diagonal type MHD generators is studied the relation between the loading factor and inclination parameter which is required for attaining the maximum power density with a given electrical efficiency on the assumption of infinitely segmented electrodes. The average current density on electrodes is calculated against the Hall parameter, loading factor, and inclination parameter. The diagonal type generator is compared with Faraday type generator regarding the average current density. Decreasing the loading factor from inlet to outlet is appropriate to small size generators but increasing to large size generators. The inclination parameter had better decrease in both generators, being smaller for small generators than for large ones. The average current density on electrodes of diagonal type generators varies less with the loading factor than the Faraday type. In large size generators its value can become smaller compared with that of the Faraday type. (author)

  1. Factor Analysis of the Aggregated Electric Vehicle Load Based on Data Mining

    Directory of Open Access Journals (Sweden)

    Yao Wang

    2012-06-01

    Full Text Available Electric vehicles (EVs and the related infrastructure are being developed rapidly. In order to evaluate the impact of factors on the aggregated EV load and to coordinate charging, a model is established to capture the relationship between the charging load and important factors based on data mining. The factors can be categorized as internal and external. The internal factors include the EV battery size, charging rate at different places, penetration of the charging infrastructure, and charging habits. The external factor is the time-of-use pricing (TOU policy. As a massive input data is necessary for data mining, an algorithm is implemented to generate a massive sample as input data which considers real-world travel patterns based on a historical travel dataset. With the input data, linear regression was used to build a linear model whose inputs were the internal factors. The impact of the internal factors on the EV load can be quantified by analyzing the sign, value, and temporal distribution of the model coefficients. The results showed that when no TOU policy is implemented, the rate of charging at home and range anxiety exerts the greatest influence on EV load. For the external factor, a support vector regression technique was used to build a relationship between the TOU policy and EV load. Then, an optimization model based on the relationship was proposed to devise a TOU policy that levels the load. The results suggest that implementing a TOU policy reduces the difference between the peak and valley loads remarkably.

  2. The physical interpretation of the threshold-stress intensity range during fatigue loading

    International Nuclear Information System (INIS)

    Marci, G.; Bazant, E.

    1977-01-01

    Based on the experimental results, the threshold-stress intensity range is given the physical interpretation that it characterizes a range of effective tensile stresses which need to be exceeded during a loading cycle for stage II fatigue crack growth to occur. The threshold stress intensity range is independent from its relative position in the range of effective tensile stress, has always the same magnitude and, furthermore, is independent of the Ksub(Imax) which produced the active plastic zone. The experimental results available from previous threshold stress intensity determinations are in good agreement with the concept developed. (orig.) [de

  3. Data transmission in long-range dielectric-loaded surface plasmon polariton waveguides

    DEFF Research Database (Denmark)

    Kharitonov, S.; Kiselev, R.; Kumar, Ashwani

    2014-01-01

    We demonstrate the data transmission of 10 Gbit/s on-off keying modulated 1550 nm signal through a long-range dielectric-loaded surface plasmon polariton waveguide structure with negligible signal degradation. In the experiment the bit error rate penalties do not exceed 0.6 dB over the 15 nm...

  4. Load Distribution Factors for Composite Multicell Box Girder Bridges

    Science.gov (United States)

    Tiwari, Sanjay; Bhargava, Pradeep

    2017-12-01

    Cellular steel section composite with a concrete deck is one of the most suitable superstructures in resisting torsional and warping effects induced by highway loading. This type of structure has inherently created new design problems for engineers in estimating its load distribution when subjected to moving vehicles. Indian Codes of Practice does not provide any specific guidelines for the design of straight composite concrete deck-steel multi-cell bridges. To meet the practical requirements arising during the design process, a simple design method is needed for straight composite multi-cell bridges in the form of load distribution factors for moment and shear. This work presents load distribution characteristics of straight composite multi-cell box girder bridges under IRC trains of loads.

  5. Generalized Efficient Inference on Factor Models with Long-Range Dependence

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre

    . Short-memory dynamics are allowed in the common factor structure and possibly heteroskedastic error term. In the estimation, a generalized version of the principal components (PC) approach is proposed to achieve efficiency. Asymptotics for efficient common factor and factor loading as well as long......A dynamic factor model is considered that contains stochastic time trends allowing for stationary and nonstationary long-range dependence. The model nests standard I(0) and I(1) behaviour smoothly in common factors and residuals, removing the necessity of a priori unit-root and stationarity testing...

  6. Ranging Behaviour of Commercial Free-Range Broiler Chickens 1: Factors Related to Flock Variability.

    Science.gov (United States)

    Taylor, Peta S; Hemsworth, Paul H; Groves, Peter J; Gebhardt-Henrich, Sabine G; Rault, Jean-Loup

    2017-07-20

    Little is known about the ranging behaviour of chickens. Understanding ranging behaviour is required to improve management and shed and range design to ensure optimal ranging opportunities. Using Radio Frequency Identification technology, we tracked 300 individual broiler chickens in each of four mixed sex ROSS 308 flocks on one commercial farm across two seasons. Ranging behaviour was tracked from the first day of range access (21 days of age) until 35 days of age in winter and 44 days of age in summer. Range use was higher than previously reported from scan sampling studies. More chickens accessed the range in summer (81%) than winter (32%; p range use was greater in summer flocks (4.4 ± 0.1 visits for a total of 26.3 ± 0.8 min/day) than winter flocks (3.2 ± 0.2 visits for a total of 7.9 ± 1.0 min/day). Seasonal differences were only marginally explained by weather conditions and may reflect the reduction in range exposure between seasons (number of days, hours per day, and time of day). Specific times of the day ( p ranging and external factors that may explain ranging preferences.

  7. An Efficient Topology for Wireless Power Transfer over a Wide Range of Loading Conditions

    Directory of Open Access Journals (Sweden)

    Tianqing Li

    2018-01-01

    Full Text Available Although an inductive power transfer (IPT system can transfer power efficiently in full-load conditions, its efficiency obviously decreases in light-load conditions. To solve this problem, based on a two-coil IPT system with a series-series compensation topology, a single-ended primary-inductor converter is introduced at the secondary side. By adjusting the set effective value of the current in the primary coil, the converter input voltage changes to maintain the equivalent input resistance of the converter in an optimal condition. The system can then transfer the power efficiently with the wide load conditions. Moreover, the system operates at a constant resonance frequency with a high power factor. Both the simulation and experimentation of a prototype with a 10 W IPT system demonstrate the effectiveness of the proposed topology for wireless power transfer.

  8. The Value Range of Contact Stiffness Factor between Pile and Soil Based on Penalty Function

    Science.gov (United States)

    Chen, Sandy H. L.; Wu, Xinliu

    2018-03-01

    The value range of contact stiffness factor based on penalty function is studied when we use finite element software ANSYS to analyze contact problems, take single pile and soil of a certain project for example, the normal contact between pile and soil is analyzed with 2D simplified model in horizontal load. The study shows that when adopting linear elastic model to simulate soil, the maximum contact pressure and penetration approach steady value as the contact stiffness factor increases. The reasonable value range of contact stiffness factor reduces as the underlying element thickness decreases, but the rule reverses when refers to the soil stiffness. If choose DP model to simulate soil, the stiffness factor should be magnified 100 times compares to the elastic model regardless of the soil bears small force and still in elastic deformation stage or into the plastic deformation stage. When the soil bears big force and into plastic deformation stage, the value range of stiffness factor relates to the plastic strain range of the soil, and reduces as the horizontal load increases.

  9. 14 CFR 23.527 - Hull and main float load factors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 23.527... Water Loads § 23.527 Hull and main float load factors. (a) Water reaction load factors nw must be...=seaplane landing weight in pounds. (6) K1=empirical hull station weighing factor, in accordance with figure...

  10. Extension of Operating Range in Pump-Turbines. Influence of Head and Load

    Directory of Open Access Journals (Sweden)

    Carme Valero

    2017-12-01

    Full Text Available Due to the increasing share of new renewable energies like wind and solar in the generation of electricity the need for power regulation and energy storage is becoming of paramount importance. One of the systems to store huge amounts of energy is pumped storage using reversible hydropower units. The machines used in these power plants are pump-turbines, which can operate as a pump and as a turbine. The surplus of electrical energy during low consumption hours can be converted into potential hydraulic energy by pumping water to a higher level. The stored energy can be converted into electricity again by operating the runner as a turbine. Due to new regulation requirements machines have to extend the operating range in order to match energy generation with consumption for the grid stability. In this paper the consequences of extending the operating range in existing pump-turbines have been studied. For that purpose, the data obtained after two years of condition monitoring were analyzed. Vibrations and pressure fluctuations of two pump-turbines of 85 MW each have been studied during pump and turbine operation. For turbine operation the effects of extending the operating range from the standard range of 45–85 MW to and increased range of 20–85 MW were analyzed. The change in vibration levels and signatures at very low load are presented with the identification of the phenomena that occur under these conditions. The influence of head in the vibration behavior is also presented. The appearance of fluid instabilities generated at part load that may produce power swing is also presented. Finally, the effect of head on the vibration levels for pump operation is shown and analyzed.

  11. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. The Poxvirus C7L Host Range Factor Superfamily

    OpenAIRE

    Liu, Jia; Rothenburg, Stefan; McFadden, Grant

    2012-01-01

    Host range factors, expressed by the poxvirus family, determine the host tropism of species, tissue, and cell specificity. C7L family members exist in the genomes of most sequenced mammalian poxviruses, suggesting an evolutionarily conserved effort adapting to the hosts. In general, C7L orthologs influence the host tropism in mammalian cell culture, and for some poxviruses it is essential for the complete viral life cycle in vitro and in vivo. The C7L family members lack obvious sequence homo...

  13. Physical and biological factors determining the effective proton range

    International Nuclear Information System (INIS)

    Grün, Rebecca; Friedrich, Thomas; Krämer, Michael; Scholz, Michael; Zink, Klemens; Durante, Marco; Engenhart-Cabillic, Rita

    2013-01-01

    Purpose: Proton radiotherapy is rapidly becoming a standard treatment option for cancer. However, even though experimental data show an increase of the relative biological effectiveness (RBE) with depth, particularly at the distal end of the treatment field, a generic RBE of 1.1 is currently used in proton radiotherapy. This discrepancy might affect the effective penetration depth of the proton beam and thus the dose to the surrounding tissue and organs at risk. The purpose of this study was thus to analyze the impact of a tissue and dose dependent RBE of protons on the effective range of the proton beam in comparison to the range based on a generic RBE of 1.1.Methods: Factors influencing the biologically effective proton range were systematically analyzed by means of treatment planning studies using the Local Effect Model (LEM IV) and the treatment planning software TRiP98. Special emphasis was put on the comparison of passive and active range modulation techniques.Results: Beam energy, tissue type, and dose level significantly affected the biological extension of the treatment field at the distal edge. Up to 4 mm increased penetration depth as compared to the depth based on a constant RBE of 1.1. The extension of the biologically effective range strongly depends on the initial proton energy used for the most distal layer of the field and correlates with the width of the distal penumbra. Thus, the range extension, in general, was more pronounced for passive as compared to active range modulation systems, whereas the maximum RBE was higher for active systems.Conclusions: The analysis showed that the physical characteristics of the proton beam in terms of the width of the distal penumbra have a great impact on the RBE gradient and thus also the biologically effective penetration depth of the beam

  14. Cognitive processing load across a wide range of listening conditions: insights from pupillometry.

    Science.gov (United States)

    Zekveld, Adriana A; Kramer, Sophia E

    2014-03-01

    The pupil response to speech masked by interfering speech was assessed across an intelligibility range from 0% to 99% correct. In total, 37 participants aged between 18 and 36 years and with normal hearing were included. Pupil dilation was largest at intermediate intelligibility levels, smaller at high intelligibility, and slightly smaller at very difficult levels. Participants who reported that they often gave up listening at low intelligibility levels had smaller pupil dilations in these conditions. Participants who were good at reading masked text had relatively large pupil dilation when intelligibility was low. We conclude that the pupil response is sensitive to processing load, and possibly reflects cognitive overload in difficult conditions. It seems affected by methodological aspects and individual abilities, but does not reflect subjective ratings. Copyright © 2014 Society for Psychophysiological Research.

  15. Metasystem approach to increase the load factor FMS

    Directory of Open Access Journals (Sweden)

    Pishchukhin Alexandr

    2017-01-01

    Full Text Available The work is devoted to increasing the efficiency of using flexible manufacture systems (FMS by increasing the load factor. Unlike the well-known multi-agent approach to production management, we are investigating the addition of a metasystem level allowing flexible combination of the decentralized control method with centralization. The metasystem approach allows to reduce management to flexible switching of functioning technologies on the basis of the replacement rule, while describing FMS as a metasystem consisting of classification of the system analyst J. Klir from structured data systems. Production events are simulated in virtual space with the help of a multi-agent approach. At the same time, the number of requests from the waiting queue is chosen such that it becomes possible to optimize the loading of the FMS in the simplest case by the full-scan method, if the queue is not available, then the initiative of choice is provided to communications of agents-technologies and agents-equipments. Experimental studies were carried out on the FMS model including six pieces of equipment divided into three groups with a stream of six applications, each of which has a technological route of six operations each‥ The experimental results showed the consistency of the developed approach by increasing the load factor of the FMS.

  16. The influence of variable range of motion training on neuromuscular performance and control of external loads.

    Science.gov (United States)

    Clark, Ross A; Humphries, Brendan; Hohmann, Erik; Bryant, Adam L

    2011-03-01

    Resistance training programs that emphasize high force production in different regions of the range of motion (ROM) may provide performance benefits. This study examined whether variable ROM (VROM) training, which consists of partial ROM training with countermovements performed in a different phase of the ROM for each set, results in improved functional performance. Twenty-two athletes (age 22.7 ± 2.4 years, height 1.81 ± 0.07 m, and body mass 94.6 ± 14.5 kg) with extensive resistance training backgrounds performed either a VROM or full ROM control (CON) 5-week, concentric work-matched training program. The participants were assigned to a group based on stratified randomization incorporating their strength levels and performance gains in preceding training microcycles. Testing consisted of assessing the force-ROM relationship during isokinetic and isometric bench press and ballistic bench throws, with normalized electromyography amplitude assessed during the isometric tests. Repeated-measure analyses of variance revealed that the VROM intervention significantly (p force (+15.7%), in addition to isokinetic peak force in the terminal ROM (13.5% increase). No significant differences were observed in the CON group or between groups for any other outcome measures. Analysis of the force-ROM relationship revealed that that the VROM intervention enhanced performance at shorter muscle lengths. These findings suggest that VROM training improves terminal and midrange performance gains, resulting in the athlete possessing an improved ability to control external loading and produce dynamic force.

  17. Research of Short-range Missile Motion in Terms of Different Wind Loads

    Directory of Open Access Journals (Sweden)

    A. N. Klishin

    2015-01-01

    Full Text Available When modeling the aircraft motion it is advisable to choose a particular model of the Earth, depending both on the task and on the required accuracy of calculation. The article describes various models of the Earth, such as the flat Earth with a plane-parallel field of gravity, spherical and non-rotating Earth with a plane-parallel field of gravity, spherical and non-rotating Earth with a central gravitational field, spherical and non-rotating Earth, taking into account the polar flattening of the Earth, spherical Earth based compression and polar daily rotation. The article also considers the influence of these models on the motion of the selected aircraft.To date, there is technical equipment to provide highly accurate description of the Earthshape, gravitational field, etc. The improved accuracy of the Earth model description results in more correct description of the trajectory and motion parameters of a ballistic missile. However, for short ranges (10-20 km this accuracy is not essential, and, furthermore, it increases time of calculation. Therefore, there is a problem of choosing the optimal description of the Earth parameters.The motion in the model of the Earth, which takes into account a daily rotation of the planet and polar flattening, is discussed in more detail, and the geographical latitude impact on coordinates of the points of fall of a ballistic missile is analyzed on the basis of obtained graphs.The article individually considers a problem of the wind effect on the aircraft motion and defines dependences of the missile motion on the parameters of different wind loads, such as wind speed and height of its action.A mathematical model of the missile motion was built and numerically integrated, using the Runge-Kutta 4th order method, for implementation and subsequent analysis.Based on the analysis of the calculation results in the abovementioned models of the Earth, differences in impact of these models on the parameters of the

  18. Instream wood loads in montane forest streams of the Colorado Front Range, USA

    Science.gov (United States)

    Jackson, Karen J.; Wohl, Ellen

    2015-04-01

    Although several studies examine instream wood loads and associated geomorphic effects in streams of subalpine forests in the U.S. Southern Rocky Mountains, little is known of instream wood loads in lower elevation, montane forests of the region. We compare instream wood loads and geomorphic effects between streams draining montane forest stands of differing age (old growth versus younger) and disturbance history (healthy versus infested by mountain pine beetles). We examined forest stand characteristics, instream wood load, channel geometry, pool volume, and sediment storage in 33 pool-riffle or plane-bed stream reaches with objectives of determining whether (i) instream wood and geomorphic effects differed significantly among old-growth, younger, healthy, and beetle-infested forest stands and (ii) wood loads correlated with valley and channel characteristics. Wood loads were standardized to drainage area, stream gradient, reach length, bankfull width, and floodplain area. Streams flowing through old-growth forests had significantly larger wood loads and logjam volumes (pairwise t-tests), as well as logjam frequencies (Kruskal-Wallis test), residual pool volume, and fine sediment storage around wood than streams flowing through younger forests. Wood loads in streams draining beetle-infested forest did not differ significantly from those in healthy forest stands, but best subset regression models indicated that elevation, stand age, and beetle infestation were the best predictors of wood loads in channels and on floodplains, suggesting that beetle infestation is affecting instream wood characteristics. Wood loads are larger than values from subalpine streams in the same region and jams are larger and more closely spaced. We interpret these differences to reflect greater wood piece mobility in subalpine zone streams. Stand age appears to exert the dominant influence on instream wood characteristics within pool-riffle streams in the study area rather than beetle

  19. A study on the load distribution factor in the perforated square plate with elastic support

    International Nuclear Information System (INIS)

    Lee, Y.S.; Yim, J.S.

    1993-01-01

    The load distribution factor in the perforated square plate supporting by angle shape legs under concentrated load acting at arbitrary points through elastic media is calculated. For the calculation the perforated plate was converted into an orthotropic plate using the method suggested by J.B. Mahoney. The deflection for the calculation of the load distribution factor was obtained from the auxiliary plate which was extended both sides of the plate and it was compared with the results from ANSYS calculation. With this deflection, the calculation of the load distribution factor was performed. The result shows that the load distribution factor at the periphery of the plate is larger than that of in the central location. This load distribution factor could be used for re-distribution of the applied load in more accurate analysis of the plate as well as in the analysis of the elastic media as the load factor. (author)

  20. Real-Time Adaptive Control of a Magnetic Levitation System with a Large Range of Load Disturbance.

    Science.gov (United States)

    Zhang, Zhizhou; Li, Xiaolong

    2018-05-11

    In an idle light-load or a full-load condition, the change of the load mass of a suspension system is very significant. If the control parameters of conventional control methods remain unchanged, the suspension performance of the control system deteriorates rapidly or even loses stability when the load mass changes in a large range. In this paper, a real-time adaptive control method for a magnetic levitation system with large range of mass changes is proposed. First, the suspension control system model of the maglev train is built up, and the stability of the closed-loop system is analyzed. Then, a fast inner current-loop is used to simplify the design of the suspension control system, and an adaptive control method is put forward to ensure that the system is still in a stable state when the load mass varies in a wide range. Simulations and experiments show that when the load mass of the maglev system varies greatly, the adaptive control method is effective to suspend the system stably with a given displacement.

  1. Load and resistance factor design of drilled shafts in shale for lateral loading.

    Science.gov (United States)

    2014-04-01

    A research project involving 32 drilled shaft load tests was undertaken to establish LRFD procedures for : design of drilled shafts subjected to lateral loads. Tests were performed at two Missouri Department of : Transportation (MoDOT) geotechnical r...

  2. Impact Study on Power Factor of Electrical Load in Power Distribution System

    International Nuclear Information System (INIS)

    Syirrazie Che Soh; Harzawardi Hasim; Ahmad Asraf, A.S.

    2014-01-01

    Low Power Factor of electrical loads cause high current is drawn from power supply. The impact of this circumstance is influenced by impedance of electrical load. Therefore, the key consideration of this study is how impedance of electrical loads influence power factor of electrical loads, and then power distribution as the whole. This study is important to evaluate the right action to mitigate low power factor effectively for electrical energy efficiency purpose. (author)

  3. Flight range, fuel load and the impact of climate change on the journeys of migrant birds

    Science.gov (United States)

    Sheard, Catherine; Butchart, Stuart H. M.

    2018-01-01

    Climate change is predicted to increase migration distances for many migratory species, but the physiological and temporal implications of longer migratory journeys have not been explored. Here, we combine information about species' flight range potential and migratory refuelling requirements to simulate the number of stopovers required and the duration of current migratory journeys for 77 bird species breeding in Europe. Using tracking data, we show that our estimates accord with recorded journey times and stopovers for most species. We then combine projections of altered migratory distances under climate change with models of avian flight to predict future migratory journeys. We find that 37% of migratory journeys undertaken by long-distance migrants will necessitate an additional stopover in future. These greater distances and the increased number of stops will substantially increase overall journey durations of many long-distance migratory species, a factor not currently considered in climate impact studies. PMID:29467262

  4. Flight range, fuel load and the impact of climate change on the journeys of migrant birds.

    Science.gov (United States)

    Howard, Christine; Stephens, Philip A; Tobias, Joseph A; Sheard, Catherine; Butchart, Stuart H M; Willis, Stephen G

    2018-02-28

    Climate change is predicted to increase migration distances for many migratory species, but the physiological and temporal implications of longer migratory journeys have not been explored. Here, we combine information about species' flight range potential and migratory refuelling requirements to simulate the number of stopovers required and the duration of current migratory journeys for 77 bird species breeding in Europe. Using tracking data, we show that our estimates accord with recorded journey times and stopovers for most species. We then combine projections of altered migratory distances under climate change with models of avian flight to predict future migratory journeys. We find that 37% of migratory journeys undertaken by long-distance migrants will necessitate an additional stopover in future. These greater distances and the increased number of stops will substantially increase overall journey durations of many long-distance migratory species, a factor not currently considered in climate impact studies. © 2018 The Authors.

  5. [Distribution of neural memory, loading factor, its regulation and optimization].

    Science.gov (United States)

    Radchenko, A N

    1999-01-01

    Recording and retrieving functions of the neural memory are simulated as a control of local conformational processes in neural synaptic fields. The localization of conformational changes is related to the afferent temporal-spatial pulse pattern flow, the microstructure of connections and a plurality of temporal delays in synaptic fields and afferent pathways. The loci of conformations are described by sets of afferent addresses named address domains. Being superimposed on each other, address domains form a multilayer covering of the address space of the neuron or the ensemble. The superposition factor determines the dissemination of the conformational process, and the fuzzing of memory, and its accuracy and reliability. The engram is formed as detects in the packing of the address space and hence can be retrieved in inverse form. The accuracy of the retrieved information depends on the threshold level of conformational transitions, the distribution of conformational changes in synaptic fields of the neuronal population, and the memory loading factor. The latter is represented in the model by a slow potential. It reflects total conformational changes and displaces the membrane potential to monostable conformational regimes, by governing the exit from the recording regime, the potentiation of the neurone, and the readiness to reproduction. A relative amplitude of the slow potential and the coefficient of postconformational modification of ionic conductivity, which provides maximum reliability, accuracy, and capacity of memory, are calculated.

  6. Moving Aerospace Structural Design Practice to a Load and Resistance Factor Approach

    Science.gov (United States)

    Larsen, Curtis E.; Raju, Ivatury S.

    2016-01-01

    Aerospace structures are traditionally designed using the factor of safety (FOS) approach. The limit load on the structure is determined and the structure is then designed for FOS times the limit load - the ultimate load. Probabilistic approaches utilize distributions for loads and strengths. Failures are predicted to occur in the region of intersection of the two distributions. The load and resistance factor design (LRFD) approach judiciously combines these two approaches by intensive calibration studies on loads and strength to result in structures that are efficient and reliable. This paper discusses these three approaches.

  7. Experimental demonstration of CMOS-compatible long-range dielectric-loaded surface plasmon-polariton waveguides (LR-DLSPPWs)

    DEFF Research Database (Denmark)

    Zektzer, Roy; Desiatov, Boris; Mazurski, Noa

    2015-01-01

    We demonstrate the design, fabrication and experimental characterization of long-range dielectric-loaded surface plasmon-polariton waveguides (LR-DLSPPWs) that are compatible with complementary metal-oxide semiconductor (CMOS) technology. The demonstrated waveguides feature good mode confinement...

  8. Finite Element Simulation of Medium-Range Blast Loading Using LS-DYNA

    Directory of Open Access Journals (Sweden)

    Yuzhen Han

    2015-01-01

    Full Text Available This study investigated the Finite Element simulation of blast loading using LS-DYNA. The objective is to identify approaches to reduce the requirement of computation effort while maintaining reasonable accuracy, focusing on blast loading scheme, element size, and its relationship with scale of explosion. The study made use of the recently developed blast loading scheme in LS-DYNA, which removes the necessity to model the explosive in the numerical models but still maintains the advantages of nonlinear fluid-structure interaction. It was found that the blast loading technique could significantly reduce the computation effort. It was also found that the initial density of air in the numerical model could be purposely increased to partially compensate the error induced by the use of relatively large air elements. Using the numerical approach, free air blast above a scaled distance of 0.4 m/kg1/3 was properly simulated, and the fluid-structure interaction at the same location could be properly duplicated using proper Arbitrary Lagrangian Eulerian (ALE coupling scheme. The study also showed that centrifuge technique, which has been successfully employed in model tests to investigate the blast effects, may be used when simulating the effect of medium- to large-scale explosion at small scaled distance.

  9. The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion.

    Science.gov (United States)

    Langohr, G Daniel G; Giles, Joshua W; Athwal, George S; Johnson, James A

    2015-06-01

    Little is known about the effects of glenosphere diameter on shoulder joint loads. The purpose of this biomechanical study was to investigate the effects of glenosphere diameter on joint load, load angle, and total deltoid force required for active abduction and range of motion in internal/external rotation and abduction. A custom, instrumented reverse shoulder arthroplasty implant system capable of measuring joint load and varying glenosphere diameter (38 and 42 mm) and glenoid offset (neutral and lateral) was implanted in 6 cadaveric shoulders to provide at least 80% power for all variables. A shoulder motion simulator was used to produce active glenohumeral and scapulothoracic motion. All implant configurations were tested with active and passive motion with joint kinematics, loads, and moments recorded. At neutral and lateralized glenosphere positions, increasing diameter significantly increased joint load (+12 ± 21 N and +6 ± 9 N; P  .8). Passive internal rotation was reduced with increased diameter at both neutral and lateralized glenosphere positions (-6° ± 6° and -12° ± 6°; P  .05). At neutral glenosphere position, increasing diameter increased the maximum angles of both adduction (+1° ± 1°; P = .03) and abduction (+8° ± 9°; P < .05). Lateralization also increased abduction range of motion compared with neutral (P < .01). Although increasing glenosphere diameter significantly increased joint load and deltoid force, the clinical impact of these changes is presently unclear. Internal rotation, however, was reduced, which contradicts previous bone modeling studies, which we postulate is due to increased posterior capsular tension as it is forced to wrap around a larger 42 mm implant assembly. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. An investigation into the RCCI engine operation under low load and its achievable operational range at different engine speeds

    International Nuclear Information System (INIS)

    Wang, Yifeng; Zhu, ZhongWen; Yao, Mingfa; Li, Tie; Zhang, Weijing; Zheng, Zunqing

    2016-01-01

    Highlights: • The response of allowable RCCI operating range to engine speed variation is studied. • The RCCI and diesel LTC engine operations at are compared at low engine load. • The potential of expanding RCCI operating range at low engine speed is explored. - Abstract: Reactivity controlled compression ignition (RCCI) is demonstrated as a promising combustion strategy to achieve high efficiency and clean combustion. However, less effort has been devoted to examine the achievable RCCI operational range over a wide range of engine speed. In addition, previous studies have found that superior EGR rate and high diesel/gasoline fuel ratio are required to ease the extension of the low-load operating range of RCCI regime. Even then, relatively high CO and HC (unburned hydrocarbon) emissions and the accompanying fuel con-sum ption penalty still remain a problem to be resolved. Therefore, in this work the potential of diesel-fueled LTC to achieve simultaneously low NOx and soot emissions while maintaining high thermal efficiency at low load (IMEP ≈0.23–0.26 MPa) is investigated and compared with the gasoline/diesel RCCI strategy. The results show that the diesel LTC operation can yield slightly higher soot and NOx emissions (soot: 0.002 g/kW h, NOx: 0.446 g/kW h), but CO and HC emissions as well as the fuel consumption are much lower than the RCCI strategy, implying the diesel LTC regime may be more suitable for low-load operations. In addition, the RCCI operational range at speeds ranging from 900 to 2500 r/min is determined, the results show that the maximum achievable load (IMEP) increases with an increase in speed, and a maximum IMEP of 1.2 MPa can be achieved at an engine speed of 2300 r/min. Ultra-low NOx and soot emissions (soot < 0.003 g/kW h, NOx < 0.4 g/kW h) can be achieved under the maximum loading conditions at each speed investigated. However, high levels of CO and HC emissions still remain a big problem to be solved. The lowest fuel consumption

  11. Analytical Dancoff factor evaluations for reactor designs loaded with TRISO particle fuel

    International Nuclear Information System (INIS)

    Ji, Wei; Liang, Chao; Pusateri, Elise N.

    2014-01-01

    Highlights: • The Dancoff factors for randomly distributed TRISO fuel particles are evaluated. • A new “dual-sphere” model is proposed to predict Dancoff factors. • The new model accurately accounts for the coating regions of fuel particles. • High accuracy is achieved over a broad range of design parameters. • The new model can be used to analyze reactors with double heterogeneity. - Abstract: A new mathematical model, the dual-sphere model, is proposed to analytically evaluate Dancoff factors of TRISO fuel kernels based on the chord method. The accurate evaluation of fuel kernel Dancoff factors is needed when one analyzes nuclear reactors loaded with TRISO particle fuel. In these reactor designs, fuel kernels are randomly distributed and shield each other, causing a shadowing effect. The Dancoff factor is a quantitative measure of this effect and is determined by the spatial distribution of fuel kernels. A TRISO fuel particle usually consists of four layers that form a coating region outside the fuel kernel. When fuel particles are loaded in the reactor, the spatial distribution of fuel kernels can be affected by the thickness of the coating region. Therefore, the coating region should be taken into account in the calculation of Dancoff factors. However, the previous model, the single-sphere model, assumes no coating regions in the Dancoff factor predictions. To address this model deficiency, the dual-sphere model is proposed by deriving a new chord length distribution function between two fuel kernels that explicitly accounts for coating regions. The new model is employed to derive analytical solutions of infinite medium, intra-fuel pebble and intra-fuel compact/pin Dancoff factors over a wide range of volume packing fractions of TRISO fuel particles, varying from 2% to 60%. Comparisons are made with the predictions from the single-sphere model and reference Monte Carlo simulations. A significant improvement of the accuracy, over the ranges of

  12. Effect of range of motion in heavy load squatting on muscle and tendon adaptations

    DEFF Research Database (Denmark)

    Bloomquist, K; Langberg, Henning; Karlsen, Stine

    2013-01-01

    Manipulating joint range of motion during squat training may have differential effects on adaptations to strength training with implications for sports and rehabilitation. Consequently, the purpose of this study was to compare the effects of squat training with a short vs. a long range of motion...

  13. A 100,000 Scale Factor Radar Range.

    Science.gov (United States)

    Blanche, Pierre-Alexandre; Neifeld, Mark; Peyghambarian, Nasser

    2017-12-19

    The radar cross section of an object is an important electromagnetic property that is often measured in anechoic chambers. However, for very large and complex structures such as ships or sea and land clutters, this common approach is not practical. The use of computer simulations is also not viable since it would take many years of computational time to model and predict the radar characteristics of such large objects. We have now devised a new scaling technique to overcome these difficulties, and make accurate measurements of the radar cross section of large items. In this article we demonstrate that by reducing the scale of the model by a factor 100,000, and using near infrared wavelength, the radar cross section can be determined in a tabletop setup. The accuracy of the method is compared to simulations, and an example of measurement is provided on a 1 mm highly detailed model of a ship. The advantages of this scaling approach is its versatility, and the possibility to perform fast, convenient, and inexpensive measurements.

  14. 14 CFR 25.527 - Hull and main float load factors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 25.527... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Water Loads § 25.527 Hull and main... 1=empirical hull station weighing factor, in accordance with figure 2 of appendix B. (7) r x=ratio...

  15. Partial safety factors for berthing velocity and loads on marine structures

    NARCIS (Netherlands)

    Roubos, A.A.; Peters, D.J.; Groenewegen, Leon; Steenbergen, R.

    2018-01-01

    Design methods for marine structures have evolved into load and resistance factor design, however existing partial safety factors related to berthing velocity and loads have not been verified and validated by measurement campaigns. In this study, field observations of modern seagoing vessels

  16. Reliability-Based Calibration of Load Duration Factors for Timber Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Svensson, Staffan; Stang, Birgitte Friis Dela

    2005-01-01

    John Dalsgaard Sørensen, Staffan Svensson, Birgitte Dela Stang : Reliability-Based Calibration of Load Duration Factors for Timber Structures     Abstract :   The load bearing capacity of timber structures decrease with time depending on the type of load and timber. Based on representative limit...... states and stochastic models for timber structures, load duration factors are calibrated using probabilistic methods. Load duration e.ects are estimated on basis of simulation of realizations of wind, snow and imposed loads in accordance with the load models in the Danish structural codes. Three damage...... accumulation models are considered, namely Gerhards model, Barrett and Foschi _ s model and Foschi and Yao _ s model. The parameters in these models are .tted by the Maximum Likelihood Method using data relevant for Danish structural timber and the statistical uncertainty is quanti .ed. The reliability...

  17. Shortening start-up and an extension of the power unit load range

    Directory of Open Access Journals (Sweden)

    Taler Jan

    2017-01-01

    Full Text Available A power plant with additional water pressure tanks was proposed. The maximum rise in the block electric power resulting from the shut-off of low-pressure regenerative heaters was determined. At that time, the boiler is fed with hot water from water pressure tanks acting as heat accumulators. Accumulation of hot water in water tanks is also proposed in the periods of the power unit small load. In order to lower the plant electric power in the off-peak night hours, water heated to the nominal temperature in low-pressure regenerative heaters is directed from the feed water tank to pressure tanks. The water accumulated during the night is used to feed the boiler during the period of peak demand for electricity. Pressure accumulators are proposed to be used for the rapid start-up of the boiler from a cold state. The evaporator of the boiler is filled at the beginning of start-up with hot water from the accumulators. Drops in the power block electric power were determined for different capacities of the tanks and periods when they are charged. The tanks may also be used to ensure a sudden increase in the electric power of the unit that is operating in the automatic system of frequency and power control (in Polish: ARCM.

  18. Calibration of Load Duration Factor kmod

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Stang, Birgitte Friis Dela; Svensson, Staffan

    and the stochastic models are formulated in accordance with the load models in the Danish structural codes, DS 409, and DS 410. three damage accumulation models are considered, namely Gerhards model, Barret & Foschi's model, and Foschi & Yao's model. The parameters in these moels are fitted using data relevant...

  19. Factors affecting host range in a generalist seed pathogen of semi-arid shrublands

    Science.gov (United States)

    Julie Beckstead; Susan E. Meyer; Kurt O. Reinhart; Kellene M. Bergen; Sandra R. Holden; Heather F. Boekweg

    2014-01-01

    Generalist pathogens can exhibit differential success on different hosts, resulting in complex host range patterns. Several factors operate to reduce realized host range relative to potential host range, particularly under field conditions. We explored factors influencing host range of the naturally occurring generalist ascomycete grass seed pathogen Pyrenophora...

  20. Design and Implementation of a Thermal Load Reduction System for a Hyundai Sonata PHEV for Improved Range

    Energy Technology Data Exchange (ETDEWEB)

    Rugh, John P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kreutzer, Cory J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Scott, Matthew [Hyundai America Technical Center Inc.; Gallagher, James [Gentherm Incoporated

    2018-04-03

    Increased adoption of electric-drive vehicles requires overcoming hurdles including limited vehicle range. Vehicle cabin heating and cooling demand for occupant climate control requires energy from the main battery and has been shown to significantly degrade vehicle range. During peak cooling and heating conditions, climate control can require as much as or more energy than propulsion. As part of an ongoing project, the National Renewable Energy Laboratory and project partners Hyundai America Technical Center, Inc., Gentherm, Pittsburgh Glass Works, PPG Industries, Sekisui, 3 M, and Hanon Systems developed a thermal load reduction system to reduce the range penalty associated with electric vehicle climate control. Solar reflective paint, solar control glass, heated and cooled/ventilated seats, heated surfaces, and a heated windshield with door demisters were integrated into a Hyundai Sonata plug-in hybrid electric vehicle. Cold weather field-testing was conducted in Fairbanks, Alaska, and warm weather testing was conducted in Death Valley, California, to assess the system performance in comparison to the baseline production vehicle. In addition, environmental chamber testing at peak heating and cooling conditions was performed to assess the performance of the system in standardized conditions compared to the baseline. Experimental results are presented in this paper, providing quantitative data to automobile manufacturers on the impact of climate control thermal load reduction technologies to increase the advanced thermal technology adoption and market penetration of electric drive vehicles.

  1. Fuel load and flight ranges of blackcaps Sylvia atricapilla in northern Iberia during autumn and spring migrations

    Directory of Open Access Journals (Sweden)

    JUAN ARIZAGA, EMILIO BARBA

    2009-12-01

    Full Text Available Fuel accumulation, mainly as fatty acids, is one of the main characteristics of migratory birds. Studying to what extent each population or species manages fuel load and how it varies along routes of migration or between seasons (autumn and spring migrations is crucial to our understanding of bird migration strategies. Our aim here was to analyse whether migratory blackcaps Sylvia atricapilla passing through northern Iberia differ in their mean fuel loads, rate of fuel accumulation and 'potential' flight ranges between migration seasons. Blackcaps were mist netted for 4 h-periods beginning at dawn from 16 September to 15 November 2003–2005, and from 1 March to 30 April 2004–2006 in a European Atlantic hedgerow at Loza, northern Iberia. Both fuel load and fuel deposition rate (this latter assessed with difference in body mass of within-season recaptured individuals were higher in autumn than in spring. Possible hypotheses explaining these results could be seasonal-associated variations in food availability (likely lower during spring than during autumn, the fact that a fraction of the migrants captured in spring could breed close to the study area and different selective pressures for breeding and wintering [Current Zoology 55 (6: 401–410, 2009].

  2. Building and environmental factors that influence bacterial and fungal loading on air conditioning cooling coils.

    Science.gov (United States)

    Bakker, A; Siegel, J A; Mendell, M J; Peccia, J

    2018-05-30

    We investigated bacterial and fungal concentrations on cooling coils of commercial AC units and quantified associations between microbial loads and AC unit or building operational parameters. A field campaign was conducted to sample 25 AC units in the humid, subtropical climate of Southern CT, USA and 15 AC units in the hot-summer Mediterranean climate of Sacramento, CA, USA. Median concentrations (with interquartile range) of bacteria and fungi on the cooling coils were 1.2 × 10 7 (5.1 × 10 6 -3.9 × 10 7 ) cells/m 2 and 7.6 × 10 5 (5.6 × 10 4 -4.4 × 10 6 ) spore equivalents (SE)/m 2 , respectively. Concentrations varied among units with median unit concentrations ranging three orders of magnitude for bacteria and seven orders of magnitude for fungi. Controlled comparisons and multivariable regressions indicate that dominant factors associated with AC coil loading include the nominal efficiency of upstream filters (P = .008 for bacteria and P < .001 for fungi) and coil moisture, which was reflected in fungal loading differences between top and bottom halves of the AC coils in Southern CT (P = .05) and the dew points of the two climates considered (P = .04). Environmental and building characteristics explained 42% (P < .001) of bacterial concentration variability and 66% (P < .001) of fungal concentration variability among samples. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Expression of muscle anabolic and metabolic factors in mechanically loaded MLO-Y4 osteocytes

    NARCIS (Netherlands)

    Juffer, P.; Jaspers, R.T.; Lips, P.; Bakker, A.D.; Klein-Nulend, J.

    2012-01-01

    Lack of physical activity results in muscle atrophy and bone loss, which can be counteracted by mechanical loading. Similar molecular signaling pathways are involved in the adaptation of muscle and bone mass to mechanical loading. Whether anabolic and metabolic factors regulating muscle mass, i.e.,

  4. The effect of some ecological factors on the intestinal parasite loads ...

    Indian Academy of Sciences (India)

    Some ecological factors that might potentially influence intestinal parasite loads in the Asian elephant (Elephas maximus Linn.) were investigated in the Nilgiris, southern India. Fresh dung samples from identified animals were analysed, and the number of eggs/g of dung used as an index of parasite load. Comparisons ...

  5. Anterior cruciate ligament injuries in soccer: Loading mechanisms, risk factors, and prevention programs

    Directory of Open Access Journals (Sweden)

    Boyi Dai

    2014-12-01

    Full Text Available Anterior cruciate ligament (ACL injuries are common in soccer. Understanding ACL loading mechanisms and risk factors for ACL injury is critical for designing effective prevention programs. The purpose of this review is to summarize the relevant literature on ACL loading mechanisms, ACL injury risk factors, and current ACL injury prevention programs for soccer players. Literature has shown that tibial anterior translation due to shear force at the proximal end of tibia is the primary ACL loading mechanism. No evidence has been found showing that knee valgus moment is the primary ACL loading mechanism. ACL loading mechanisms are largely ignored in previous studies on risk factors for ACL injury. Identified risk factors have little connections to ACL loading mechanisms. The results of studies on ACL injury prevention programs for soccer players are inconsistent. Current ACL injury prevention programs for soccer players are clinically ineffective due to low compliance. Future studies are urgently needed to identify risk factors for ACL injury in soccer that are connected to ACL loading mechanisms and have cause-and-effect relationships with injury rate, and to develop new prevention programs to improve compliance.

  6. Load and resistance factor rating (LRFR) in New York State : volume II.

    Science.gov (United States)

    2011-09-01

    This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...

  7. Load and resistance factor rating (LRFR) in New York State : volume I.

    Science.gov (United States)

    2011-09-01

    This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...

  8. Researching Complex Heat, Air and Moisture Interactions for a Wide-Range of Building Envelope Systems and Environmental Loads

    Energy Technology Data Exchange (ETDEWEB)

    Karagiozis, A.N.

    2007-05-15

    This document serves as the final report documenting work completed by Oak Ridge National Laboratory (ORNL) and the Fraunhofer Institute in Building Physics (Holzkirchen, Germany) under an international CRADA No. 0575 with Fraunhofer Institute of Bauphysics of the Federal Republic of Germany for Researching Complex Heat, Air and Moisture Interactions for a Wide Range of Building Envelope Systems and Environmental Loads. This CRADA required a multi-faceted approach to building envelope research that included a moisture engineering approach by blending extensive material property analysis, laboratory system and sub-system thermal and moisture testing, and advanced moisture analysis prediction performance. The Participant's Institute for Building physics (IBP) and the Contractor's Buildings Technology Center (BTC) identified potential research projects and activities capable of accelerating and advancing the development of innovative, low energy and durable building envelope systems in diverse climates. This allowed a major leverage of the limited resources available to ORNL to execute the required Department of Energy (DOE) directives in the area of moisture engineering. A joint working group (ORNL and Fraunhofer IBP) was assembled and a research plan was executed from May 2000 to May 2005. A number of key deliverables were produced such as adoption of North American loading into the WUFI-software. in addition the ORNL Weather File Analyzer was created and this has been used to address environmental loading for a variety of US climates. At least 4 papers have been co-written with the CRADA partners, and a chapter in the ASTM Manual 40 on Moisture Analysis and Condensation Control. All deliverables and goals were met and exceeded making this collaboration a success to all parties involves.

  9. Stress-intensity factor equations for cracks in three-dimensional finite bodies subjected to tension and bending loads

    Science.gov (United States)

    Newman, J. C., Jr.; Raju, I. S.

    1984-01-01

    Stress intensity factor equations are presented for an embedded elliptical crack, a semielliptical surface crack, a quarter elliptical corner crack, a semielliptical surface crack along the bore of a circular hole, and a quarter elliptical corner crack at the edge of a circular hole in finite plates. The plates were subjected to either remote tension or bending loads. The stress intensity factors used to develop these equations were obtained from previous three dimensional finite element analyses of these crack configurations. The equations give stress intensity factors as a function of parametric angle, crack depth, crack length, plate thickness, and, where applicable, hole radius. The ratio of crack depth to plate thickness ranged from 0 to 1, the ratio of crack depth to crack length ranged from 0.2 to 2, and the ratio of hole radius to plate thickness ranged from 0.5 to 2. The effects of plate width on stress intensity variation along the crack front were also included.

  10. Effect of diatomaceous earth on parasite load, egg production, and egg quality of free-range organic laying hens.

    Science.gov (United States)

    Bennett, D C; Yee, A; Rhee, Y-J; Cheng, K M

    2011-07-01

    The effectiveness of diatomaceous earth (DE) as a treatment against parasites and to increase feed efficiency and egg production of organically raised free-range layer hens was evaluated in 2 breeds of commercial egg layers [Bovan Brown (BB) and Lowmann Brown (LB)] that differ in their resistance to internal parasitic infections. Half the hens of each breed were fed diets supplemented with DE (2%). Their internal parasite loads were assessed by biweekly fecal egg counts (FEC) and by postmortem examination of the gastrointestinal tract. Supplementing DE in diets of LB hens, the more parasite-resistant breed, did not significantly affect their FEC and adult parasite load. However, BB hens treated with dietary DE had significantly lower Capillaria FEC, slightly lower Eimeria FEC, fewer birds infected with Heterakis, and significantly lower Heterakis worm burden than control BB hens. Both BB and LB hens fed the diet containing DE were significantly heavier, laid more eggs, and consumed more feed than hens fed the control diet, but feed efficiency did not differ between the 2 dietary treatments. Additionally, BB hens consuming the DE diet laid larger eggs containing more albumen and yolk than hens consuming the control diet. In a subsequent experiment, the effectiveness of DE to treat a Northern fowl mite (Ornithonyssus sylviarum) infestation was tested. Relative to controls, both breeds of hens that were dusted with DE had reduced number of mites. The results of this study indicate the DE has the potential to be an effective treatment to help control parasites and improve production of organically raised, free-range layer hens.

  11. Power factor improvement in three-phase networks with unbalanced inductive loads using the Roederstein ESTAmat RPR power factor controller

    Science.gov (United States)

    Diniş, C. M.; Cunţan, C. D.; Rob, R. O. S.; Popa, G. N.

    2018-01-01

    The paper presents the analysis of a power factor with capacitors banks, without series coils, used for improving power factor for a three-phase and single-phase inductive loads. In the experimental measurements, to improve the power factor, the Roederstein ESTAmat RPR power factor controller can command up to twelve capacitors banks, while experimenting using only six capacitors banks. Six delta capacitors banks with approximately equal reactive powers were used for experimentation. The experimental measurements were carried out with a three-phase power quality analyser which worked in three cases: a case without a controller with all capacitors banks permanently parallel connected with network, and two other cases with power factor controller (one with setting power factor at 0.92 and the other one at 1). When performing experiments with the power factor controller, a current transformer was used to measure the current on one phase (at a more charged or less loaded phase).

  12. Combustion and emission characteristics of Multiple Premixed Compression Ignition (MPCI) fuelled with naphtha and gasoline in wide load range

    International Nuclear Information System (INIS)

    Wang, Buyu; Wang, Zhi; Shuai, Shijin; Yang, Hongqiang; Wang, Jianxin

    2014-01-01

    Highlights: • Naphtha MPCI can operate stably in wide load range from 0.4 MPa to 1.4 MPa of IMEP. • Naphtha MPCI can achieve high thermal efficiency due to low exhaust loss. • Gasoline MPCI has low heat transfer loss than CDC and naphtha MPCI. • MPCI can produce low NO x emissions (<0.4 g/kW h) with the EGR ratio less than 30%. - Abstract: This paper investigates the effect of naphtha (RON = 65.6) and commercial gasoline (RON = 94.0) on Multiple Premixed Compression Ignition (MPCI) mode. The experiment is conducted on a single cylinder research diesel engine with compression ratio of 16.7. The engine is operated at an engine speed of 1600 rpm for the IMEP from 0.4 to 1.4 MPa. Commercial diesel (CN = 56.5) is also tested in Conventional Diesel Combustion (CDC) mode as a baseline. At each operating point, the injection strategy and intake conditions are adjusted to meet with the criteria (NO x < 0.4 g/kW h, soot < 0.06 m −1 , MPRR < 1 MPa/deg and CA50 < 20 CAD ATDC). The typical two-stage combustion characteristics of MPCI are obtained in both naphtha and gasoline. Stable combustion is achieved by naphtha in wide load range, while the engine fuelled with gasoline cannot operate stably at 0.4 MPa IMEP. The COV of IMEP of gasoline MPCI is higher than that of naphtha and diesel. However, gasoline has the low MPRR and the retarded CA50 at medium and high loads due to its longest ignition delay. As a result of low exhaust loss for naphtha and low heat transfer loss for gasoline, the thermal efficiencies are higher for both naphtha and gasoline in MPCI mode than diesel in CDC mode, even though diesel has the highest combustion efficiency. The separated combustion in MPCI leads to low cylinder temperature, and moderate EGR ratio (less than 30%) is needed to control NO x emissions under the limit of EURO VI

  13. Reliability-based load and resistance factor design for piping: an exploratory case study

    International Nuclear Information System (INIS)

    Gupta, Abhinav; Choi, Byounghoan

    2003-01-01

    This paper presents an exploratory case study on the application of Load and Resistance Factor Design (LRFD) approach to the Section III of ASME Boiler and Pressure Vessel code for piping design. The failure criterion for defining the performance function is considered as plastic instability. Presently used design equation is calibrated by evaluating the minimum reliability levels associated with it. If the target reliability in the LRFD approach is same as that evaluated for the presently used design equation, it is shown that the total safety factors for the two design equations are identical. It is observed that the load and resistance factors are not dependent upon the diameter to thickness ratio. A sensitivity analysis is also conducted to study the variations in the load and resistance factors due to changes in (a) coefficients of variation for pressure, moment, and ultimate stress, (b) ratio of mean design pressure to mean design moment, (c) distribution types used for characterizing the random variables, and (d) statistical correlation between random variables. It is observed that characterization of random variables by log-normal distribution is reasonable. Consideration of statistical correlation between the ultimate stress and section modulus gives higher values of the load factor for pressure but lower value for the moment than the corresponding values obtained by considering the variables to be uncorrelated. Since the effect of statistical correlation on the load and resistance factors is relatively insignificant for target reliability values of practical interest, the effect of correlated variables may be neglected

  14. Fatigue analysis - computation of the actual strain range using elastic calculations (factor Ke)

    International Nuclear Information System (INIS)

    Roche, R.L.

    1987-01-01

    Pressure vessels are not eternal, their life is not endless, but must be long enough for profitable use. Fatigue is the most important damage limiting life time. It is due to variable loading and especially to deformation-controlled loading like thermal dilatation (thermal stress). Hence, it is of prime importance to perform an fatigue analysis in the design phase in order to be sure the pressure vessel life meet requirement of the design specification. It is also useful to perform such an analysis for assessing the remaining life. To compute the fatigue damage, knowledge of the strain range is needed. As calculation taking into account non linear behavior of the material are very expensive and not always reliable, the current practice is using elastic computation. The aim of this paper is to discuss the methods for correcting the elastically calculated strain range and to propose a sound and practical method

  15. Environmental load factors and system strength evaluation of offshore jacket platforms

    CERN Document Server

    Nizamani, Zafarullah

    2015-01-01

    This book presents a study for the determination of environmental load factors for Jacket Platforms in Malaysia and a methodology to determine the life extension of aging platforms. The simplified methods described here could be used for determining not only structural reliability but also safety factors. Its content is particularly interesting to design and maintenance engineers who are working in offshore or onshore industry.

  16. Importance of nuclear station load factor in applied ro energy policies

    International Nuclear Information System (INIS)

    Gomes, Daniel de Souza

    2015-01-01

    Load factor is the ration between the energy produced by a station and the energy it would have produced running at maximum power. The factor intends for all types of commercial reactors. Nuclear plants continuously provide over 11% of the world's electricity. The reactors for which data were available generated 618.7 TWh of electricity in 2014. Typical load factor was around 75% in worldwide during the first quarter of 2015. In this manner, it obtained from an average, three-monthly or yearly. The regular load factor of the reactors in operation was around 56% in 1970. While, in 1980's decade, we have an increase to 63%, the same situation occurred in next the decade and suffering increasing to 73%. Currently, the load factor reaches 78%. Accidents are seasonal factors, with the occurrence of reduction of power generation plants. In 2015 in January, there are over 437 operable commercial reactors in 31 countries, with over 377,728 MWe of full capacity. In Brazil, total capacity is 1901 MWe, with around 2.8% of electricity energy consumed. The primary objective of this study was to find a forecast model that express the evolution of the load factor in the next years. In recent years occur an extensive development of pressurized water reactors in Asia. The periodicity of seasonal effects on the performance of nuclear power plants due to aging. However, the impact of plant age depended on new technologies that allow the growth of the performance. The accident of Fukushima was an inflection point for energy policies. The event produced a trend that reduced the load in the world. (author)

  17. Modeling and Finite Element Analysis of Load-Carrying Performance of a Wind Turbine Considering the Influence of Assembly Factors

    Directory of Open Access Journals (Sweden)

    Jianmei Wang

    2017-03-01

    Full Text Available In this work, a wind turbine shrink disk is used as the research object to investigate load-carrying performance of a multi-layer interference fit, and the theoretical model and finite element model are constructed. According to those models, a MW-level turbine shrink disk is designed, and a test device is developed to apply torque to this turbine shrink disk by hydraulic jack. Then, the circumferential slip between the contact surfaces is monitored and the slip of all contact surfaces is zero. This conclusion verifies the reasonability of the proposed models. The effect of the key influencing factors, such as machining deviation, assembly clearance and propel stroke, were analyzed. The contact pressure and load torque of the mating surfaces were obtained by building typical models with different parameters using finite element analysis (FEA. The results show that the minimum assembly clearance and the machining deviation within the machining range have little influence on load-carrying performance of multi-layer interference fit, while having a greater influence on the maximum assembly clearance and the propel stroke. The results also show that the load-carrying performance of a multiple-layer interference fit can be ensured only if the key factors are set within a reasonable design range. To avoid the abnormal operation of equipment caused by insufficient load torque, the propel stroke during practical assembly should be at least 0.95 times the designed propel stroke, which is significant in guiding the design and assembly of the multi-layer interference fit.

  18. What is the relationship between mental workload factors and cognitive load types?

    Science.gov (United States)

    Galy, Edith; Cariou, Magali; Mélan, Claudine

    2012-03-01

    The present study tested the hypothesis of an additive interaction between intrinsic, extraneous and germane cognitive load, by manipulating factors of mental workload assumed to have a specific effect on either type of cognitive load. The study of cognitive load factors and their interaction is essential if we are to improve workers' wellbeing and safety at work. High cognitive load requires the individual to allocate extra resources to entering information. It is thought that this demand for extra resources may reduce processing efficiency and performance. The present study tested the effects of three factors thought to act on either cognitive load type, i.e. task difficulty, time pressure and alertness in a working memory task. Results revealed additive effects of task difficulty and time pressure, and a modulation by alertness on behavioral, subjective and psychophysiological workload measures. Mental overload can be the result of a combination of task-related components, but its occurrence may also depend on subject-related characteristics, including alertness. Solutions designed to reduce incidents and accidents at work should consider work organization in addition to task constraints in so far that both these factors may interfere with mental workload. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Means of achieving high load factors at Olkiluoto 1 and 2

    International Nuclear Information System (INIS)

    Patrakka, E.

    2001-01-01

    Teollisuuden Voima Oy operates two BWR units Olkiluoto 1 and 2 that have achieved load factors typically higher than 90%. The operating experiences gained in the 1990s is summarised and the factors contributing to the high capacity factors are addressed. These include the general objectives for operation and maintenance, plant modernisation programme, maintenance principles, and outage policy and experiences. Finally, the international evaluations performed at Olkiluoto are mentioned. (author)

  20. The effect of load factor on fission product decay heat from discharged reactor fuel

    International Nuclear Information System (INIS)

    Davies, B.S.J.

    1978-07-01

    A sum-of-exponentials expression representing the decay heat power following a burst thermal irradiation of 235 U has been used to investigate the effect of load factor during irradiation on subsequent decay heat production. A sequence of random numbers was used to indicate reactor 'on' and 'off' periods for irradiations which continued for a total of 1500 days at power and were followed by 100 days cooling. It was found that for these conditions decay heat is almost proportional to load factor. Estimates of decay heat uncertainty arising from the random irradiation pattern are also given. (author)

  1. Nerve growth factor loaded heparin/chitosan scaffolds for accelerating peripheral nerve regeneration.

    Science.gov (United States)

    Li, Guicai; Xiao, Qinzhi; Zhang, Luzhong; Zhao, Yahong; Yang, Yumin

    2017-09-01

    Artificial chitosan scaffolds have been widely investigated for peripheral nerve regeneration. However, the effect was not as good as that of autologous grafts and therefore could not meet the clinical requirement. In the present study, the nerve growth factor (NGF) loaded heparin/chitosan scaffolds were fabricated via electrostatic interaction for further improving nerve regeneration. The physicochemical properties including morphology, wettability and composition were measured. The heparin immobilization, NGF loading and release were quantitatively and qualitatively characterized, respectively. The effect of NGF loaded heparin/chitosan scaffolds on nerve regeneration was evaluated by Schwann cells culture for different periods. The results showed that the heparin immobilization and NGF loading did not cause the change of bulk properties of chitosan scaffolds except for morphology and wettability. The pre-immobilization of heparin in chitosan scaffolds could enhance the stability of subsequently loaded NGF. The NGF loaded heparin/chitosan scaffolds could obviously improve the attachment and proliferation of Schwann cells in vitro. More importantly, the NGF loaded heparin/chitosan scaffolds could effectively promote the morphology development of Schwann cells. The study may provide a useful experimental basis to design and develop artificial implants for peripheral nerve regeneration and other tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Serviceability design load factors and reliability assessments for reinforced concrete containment structures

    International Nuclear Information System (INIS)

    Han Bong Koo

    1998-01-01

    A reinforced concrete nuclear power plant containment structure is subjected to various random static and stochastic loads during its lifetime. Since these loads involve inherent randomness and other uncertainties, an appropriate probabilistic model for each load must be established in order to perform reliability analysis. The current ASME code for reinforced concrete containment structures are not based on probability concepts. The stochastic nature of natural hazard or accidental loads and the variations of material properties require a probabilistic approach for a rational assessment of structural safety and performance. The paper develops probability-based load factors for the limit state design of reinforced concrete containment structures. The purpose of constructing reinforced concrete containment structure is to protect against radioactive release, and so the use of a serviceability limit state against crack failure that can cause the emission of radioactive materials is suggested as a critical limit state for reinforced concrete containment structures. Load factors for the design of reinforced concrete containment structures are proposed and carried out the reliability assessments. (orig.)

  3. Ecological ranges for the pH and NO3 of syntaxa: a new basis for the estimation of critical loads for acid and nitrogen deposition

    NARCIS (Netherlands)

    Wamelink, G.W.W.; Goedhart, P.W.; Malinowska, A.H.; Frissel, J.Y.; Wegman, R.M.A.; Slim, P.A.; Dobben, van H.F.

    2011-01-01

    Question: Can the abiotic ranges of syntaxonomic units (associations) in terms of pH and nitrate concentration be estimated and then in principle be used to estimate critical loads for acid and nitrogen deposition? Location: Europe. Methods: Using splines, abiotic ranges of syntaxonomic units were

  4. Factors affecting stream nutrient loads: A synthesis of regional SPARROW model results for the continental United States

    Science.gov (United States)

    Preston, Stephen D.; Alexander, Richard B.; Schwarz, Gregory E.; Crawford, Charles G.

    2011-01-01

    We compared the results of 12 recently calibrated regional SPARROW (SPAtially Referenced Regressions On Watershed attributes) models covering most of the continental United States to evaluate the consistency and regional differences in factors affecting stream nutrient loads. The models - 6 for total nitrogen and 6 for total phosphorus - all provide similar levels of prediction accuracy, but those for major river basins in the eastern half of the country were somewhat more accurate. The models simulate long-term mean annual stream nutrient loads as a function of a wide range of known sources and climatic (precipitation, temperature), landscape (e.g., soils, geology), and aquatic factors affecting nutrient fate and transport. The results confirm the dominant effects of urban and agricultural sources on stream nutrient loads nationally and regionally, but reveal considerable spatial variability in the specific types of sources that control water quality. These include regional differences in the relative importance of different types of urban (municipal and industrial point vs. diffuse urban runoff) and agriculture (crop cultivation vs. animal waste) sources, as well as the effects of atmospheric deposition, mining, and background (e.g., soil phosphorus) sources on stream nutrients. Overall, we found that the SPARROW model results provide a consistent set of information for identifying the major sources and environmental factors affecting nutrient fate and transport in United States watersheds at regional and subregional scales. ?? 2011 American Water Resources Association. This article is a U.S. Government work and is in the public domain in the USA.

  5. National implementation of the UNECE convention on long-range transboundary air pollution (effects). Pt. 1. Deposition loads: methods, modelling and mapping results, trends

    Energy Technology Data Exchange (ETDEWEB)

    Gauger, Thomas [Federal Agricultural Research Centre, Braunschweig (DE). Inst. of Agroecology (FAL-AOE); Stuttgart Univ. (Germany). Inst. of Navigation; Haenel, Hans-Dieter; Roesemann, Claus [Federal Agricultural Research Centre, Braunschweig (DE). Inst. of Agroecology (FAL-AOE)

    2008-09-15

    The report on the implementation of the UNECE convention on long-range transboundary air pollution Pt.1, deposition loads (methods, modeling and mapping results, trends) includes the following chapters: Introduction, deposition on air pollutants used for the input for critical loads in exceeding calculations, methods applied for mapping total deposition loads, mapping wet deposition, wet deposition mapping results, mapping dry deposition, dry deposition mapping results, cloud and fog mapping results, total deposition mapping results, modeling the air concentration of acidifying components and heavy metals, agricultural emissions of acidifying and eutrophying species.

  6. Effect of Feed Additives on Productivity and Campylobacter spp. Loads in Broilers Reared under Free Range Conditions.

    Science.gov (United States)

    Guyard-Nicodème, Muriel; Huneau-Salaün, Adeline; Tatone, Fabrizio A; Skiba, Fabien; Quentin, Maxime; Quesne, Ségolène; Poezevara, Typhaine; Chemaly, Marianne

    2017-01-01

    The poultry reservoir, especially broiler meat, is generally recognized as one of the most-important sources for human Campylobacteriosis. The measures to control Campylobacter targeted essentially the primary production level. The aim of this work was to evaluate the effectiveness of different treatments against natural Campylobacter colonization in a French experimental farm of free-range broilers during the whole rearing period. Five commercial products and a combination of two of them were tested and all the products were added to feed or to water at the dose recommended by the suppliers. Campylobacter loads in caeca and on carcasses of broilers at the slaughter were determined by culture methods. Natural contamination of the flock occurred at the end of the indoor rearing period between day 35 and day 42. At day 42, the multispecies probiotic added to the feed reduced the contamination of 0.55 log 10 CFU/g ( p = 0.02) but was not significant ( p > 0.05) at the end of rearing at day 78. However, another treatment, a combination of a cation exchange clay-based product in feed and an organic acid mixture (formic acid, sodium formate, lactic acid, propionic acid) in water, led to a slight but significant reduction of 0.82 ± 0.25 log 10 CFU/g ( p = 0.02) compared to the control group at day 78. Testing this combination in field conditions in several flocks is needed to determine if it is biologically relevant and if it could be a valuable measure to reduce Campylobacter in broiler flocks.

  7. Effect of Feed Additives on Productivity and Campylobacter spp. Loads in Broilers Reared under Free Range Conditions

    Directory of Open Access Journals (Sweden)

    Muriel Guyard-Nicodème

    2017-05-01

    Full Text Available The poultry reservoir, especially broiler meat, is generally recognized as one of the most-important sources for human Campylobacteriosis. The measures to control Campylobacter targeted essentially the primary production level. The aim of this work was to evaluate the effectiveness of different treatments against natural Campylobacter colonization in a French experimental farm of free-range broilers during the whole rearing period. Five commercial products and a combination of two of them were tested and all the products were added to feed or to water at the dose recommended by the suppliers. Campylobacter loads in caeca and on carcasses of broilers at the slaughter were determined by culture methods. Natural contamination of the flock occurred at the end of the indoor rearing period between day 35 and day 42. At day 42, the multispecies probiotic added to the feed reduced the contamination of 0.55 log10 CFU/g (p = 0.02 but was not significant (p > 0.05 at the end of rearing at day 78. However, another treatment, a combination of a cation exchange clay-based product in feed and an organic acid mixture (formic acid, sodium formate, lactic acid, propionic acid in water, led to a slight but significant reduction of 0.82 ± 0.25 log10 CFU/g (p = 0.02 compared to the control group at day 78. Testing this combination in field conditions in several flocks is needed to determine if it is biologically relevant and if it could be a valuable measure to reduce Campylobacter in broiler flocks.

  8. General Factor Loadings and Specific Effects of the Differential Ability Scales, Second Edition Composites

    Science.gov (United States)

    Maynard, Jennifer L.; Floyd, Randy G.; Acklie, Teresa J.; Houston, Lawrence, III

    2011-01-01

    The purpose of this study was to investigate the "g" loadings and specific effects of the core and diagnostic composite scores from the Differential Abilities Scales, Second Edition (DAS-II; Elliott, 2007a). Scores from a subset of the DAS-II standardization sample for ages 3:6 to 17:11 were submitted to principal factor analysis. Four…

  9. technical note: technical note: on the correctness of load loss factor ...

    African Journals Online (AJOL)

    eobe

    Load Loss Factor (LLF) is a function of the estimate of the losses between the grid supply point and the consumers. estimate ... i.e. the ratio of average demand to peak demand, and using this ratio to determine an approximation to the. LLF via ...

  10. The stress and stress intensity factors computation by BEM and FEM combination for nozzle junction under pressure and thermal loads

    International Nuclear Information System (INIS)

    Du, Q.; Cen, Z.; Zhu, H.

    1989-01-01

    This paper reports linear elastic fracture analysis based upon the stress intensity factor evaluation successfully applied to safety assessments of cracked structures. The nozzle junction are usually subjected to high pressure and thermal loads simultaneously. In validity of linear elastic fracture analysis, K can be decomposed into K P (caused by mechanic loads) and K τ (caused by thermal loads). Under thermal transient loading, explicit analysis (say by the FEM or BEM) of K tracing an entire history respectively for a range of crack depth may be much more time consuming. The techniques of weight function provide efficient means for transforming the problem into the stress computation of the uncracked structure and generation of influence function (for the given structure and size of crack). In this paper, a combination of BE-FEM has been used for the analysis of the cracked nozzle structure by techniques of weight function. The influence functions are obtained by coupled BE-FEM and the uncracked structure stress are computed by finite element methods

  11. Determination of Actual Friction Factors in Metal Forming under Heavy Loaded Regimes Combining Experimental and Numerical Analysis

    Science.gov (United States)

    Camacho, Ana María; Veganzones, Mariano; Claver, Juan; Martín, Francisco; Sevilla, Lorenzo; Sebastián, Miguel Ángel

    2016-01-01

    Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE) simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS2 grease, silicone oil, and copper paste) to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs). The results show that for small reductions (rh 20%), it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered. PMID:28773868

  12. Determination of Actual Friction Factors in Metal Forming under Heavy Loaded Regimes Combining Experimental and Numerical Analysis

    Directory of Open Access Journals (Sweden)

    Ana María Camacho

    2016-09-01

    Full Text Available Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS2 grease, silicone oil, and copper paste to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs. The results show that for small reductions (rh < 20%, the conventional RCT can be applied because the tribological conditions remain similar. For large reductions (rh > 20%, it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered.

  13. Psychosocial factors and mental work load: a reality perceived by nurses in intensive care units

    Directory of Open Access Journals (Sweden)

    Paula Ceballos-Vásquez

    2015-04-01

    Full Text Available OBJECTIVE: To analyse the perception of psychosocial factors and mental workload of nurses who work in intensive care units. It is hypothesised that nurses in these units could perceive psychosocial risks, manifesting in a high mental work load. The psychosocial dimension related to the position's cognitive demands is hypothesised to mostly explain mental work load. METHOD: Quantitative study, with a descriptive, cross-sectional, and comparative design. A total of 91% of the intensive care unit populations of three Chilean hospitals was surveyed, corresponding to 111 nurses. The instruments utilised included (A a biosociodemographic history questionnaire; (b the SUSESO-ISTAS 21 questionnaire; and (c the Mental Work Load Subjective Scale (ESCAM, in Spanish. RESULTS: In total, 64% and 57% of participants perceived high levels of exposure to the psychosocial risks Psychosocial demands and Double shift, respectively. In addition, a medium-high level of overall mental load was observed. Positive and significant correlations between some of the SUSESO-ISTAS 21 and ESCAM dimensions were obtained. Using a regression analysis, it was determined that three dimensions of the psychosocial risk questionnaire helped to explain 38% of the overall mental load. CONCLUSION: Intensive care unit nurses felt that inadequate psychosocial factors and mental work overload existed in several of the tested dimensions.

  14. System incremental cost calculations using the participation factor load-flow formulation

    International Nuclear Information System (INIS)

    Meisel, J.

    1993-01-01

    The load-flow problem is reformulated such that the use of a slack-bus generator is included only as a special case. This reformulation, known as the participation factor load-flow, includes a total mismatch variable and a defined participation vector, which, in general, distributes this mismatch to all system buses. The slack-bus constraint can still be obtained by defining a particular participation vector. In using the participation factor load-flow in the transpose Jacobian approach to the economic optimal dispatch problem, the paper shows that the value of the system-λ can be controlled such that this value represents the minimal incremental change in generation costs per unit change in system total demand with this demand distributed according to the specified participation vector. Methods using the conventional B-coefficient loss formulas or slack-bus load-flows give system-λ values whereby the unit change in demand must be placed on a fictitious single load-bus or on the slack-bus, respectively. Having a system-λ value which more accurately represents a proposed energy interchange between interconnected systems is very important in developing valid costs for each system. An extensive 28-bus, 8-generator system is included to illustrate these results

  15. Analysis of bus passenger comfort perception based on passenger load factor and in-vehicle time.

    Science.gov (United States)

    Shen, Xianghao; Feng, Shumin; Li, Zhenning; Hu, Baoyu

    2016-01-01

    Although bus comfort is a crucial indicator of service quality, existing studies tend to focus on passenger load and ignore in-vehicle time, which can also affect passengers' comfort perception. Therefore, by conducting surveys, this study examines passengers' comfort perception while accounting for both factors. Then, using the survey data, it performs a two-way analysis of variance and shows that both in-vehicle time and passenger load significantly affect passenger comfort. Then, a bus comfort model is proposed to evaluate comfort level, followed by a sensitivity analysis. The method introduced in this study has theoretical implications for bus operators attempting to improve bus service quality.

  16. Influence of overelastic loading on the stress intensity factor under thermal fatigue conditions

    International Nuclear Information System (INIS)

    Stamm, H.; Munz, D.

    1983-10-01

    Thermal shock loading often creates high thermal stresses which may exceed yield strength of the material in a surface layer. In this report the application of the linear elastic ΔK-concept in the case of cyclic thermal loading within the shakedown region is discussed. To this K-factors for an edge crack in a linear elastic - perfectly plastic plate are calculated using the weight function method and are compared with results obtained with the Finite Element Method. It is shown, that rearrangement stresses during plastic flow in the first cycle must be taken into account developing conservative approximation procedures. (orig.) [de

  17. A New V2G Control Strategy for Load Factor Improvement Using Smoothing Technique

    Directory of Open Access Journals (Sweden)

    CHANHOM, P.

    2017-08-01

    Full Text Available This paper proposes a new vehicle-to-grid (V2G control strategy for improving the load factor in the power network. To operate the proposed strategy, the available storage capacity of the PEVs’ batteries is considered as a battery energy storage system (BESS for charging and discharging an amount of power corresponding to the V2G power command. Due to the remarkable advantages of the technique so-called simple moving average, it is selected for applying in the proposed V2G control strategy. In this research, for investigating the load factor improvement, the essential data including the daily-load profiles with 7-day and 14-day periods are used for the 3 studied cases. These 3 studied cases present the power network with variation of the PEVs locations for describing the PEVs usage and charging or discharging behavior. The performance of the proposed strategy is simulated and verified by the MATPOWER software. The simulation results show that the load factors of the 3 studied cases are improved. Moreover, the encouragement of energy arbitrage for the PEVs owners is also discussed in this paper.

  18. Selective Synthesis of Gasoline-Ranged Hydrocarbons from Syngas over Hybrid Catalyst Consisting of Metal-Loaded ZSM-5 Coupled with Copper-Zinc Oxide

    Directory of Open Access Journals (Sweden)

    Ting Ma

    2014-04-01

    Full Text Available The conversion of syngas (CO + H2 to gasoline-ranged hydrocarbons was carried out using a hybrid catalyst consisting of metal-loaded ZSM-5 coupled with Cu-ZnO in a near-critical n-hexane solvent. Methanol was synthesized from syngas over Cu-ZnO; subsequently, was converted to hydrocarbons through the formation of dimethyl ether (DME over the metal-loaded ZSM-5. When 0.5 wt% Pd/ZSM-5 and 5 wt% Cu/ZSM-5 among the metal-loaded ZSM-5 catalysts with Pd, Co, Fe or Cu were employed as a portion of the hybrid catalyst, the gasoline-ranged hydrocarbons were selectively produced (the gasoline-ranged hydrocarbons in all hydrocarbons: 59% for the hybrid catalyst with Pd/ZSM-5 and 64% for that with Cu/ZSM-5 with a similar CO conversion during the reaction. An increase in the Cu loading on ZSM-5 resulted in increasing the yield of the gasoline-ranged hydrocarbons, and in decreasing the yield of DME. Furthermore, the hybrid catalyst with Cu/ZSM-5 exhibited no deactivation for 30 h of the reaction. It was revealed that a hybrid catalyst containing Cu/ZSM-5 was efficient in the selective synthesis of gasoline-ranged hydrocarbons from syngas via methanol in the near-critical n-hexane fluid.

  19. Development of reliability-based load and resistance factor design methods for piping

    International Nuclear Information System (INIS)

    Ayyub, Bilal M.; Hill, Ralph S. III; Balkey, Kenneth R.

    2003-01-01

    Current American Society of Mechanical Engineers (ASME) nuclear codes and standards rely primarily on deterministic and mechanistic approaches to design. The American Institute of Steel Construction and the American Concrete Institute, among other organizations, have incorporated probabilistic methodologies into their design codes. ASME nuclear codes and standards could benefit from developing a probabilistic, reliability-based, design methodology. This paper provides a plan to develop the technical basis for reliability-based, load and resistance factor design of ASME Section III, Class 2/3 piping for primary loading, i.e., pressure, deadweight and seismic. The plan provides a proof of concept in that LRFD can be used in the design of piping, and could achieve consistent reliability levels. Also, the results from future projects in this area could form the basis for code cases, and additional research for piping secondary loads. (author)

  20. Factors controlling strength of structures, and anticipated overstrength for seismic load conditions

    International Nuclear Information System (INIS)

    Singh, A.K.

    1985-01-01

    This paper discusses how the safe shutdown earthquake level, the ratio of operating basis earthquake to safe shutdown earthquake level, the shape of the earthquake spectra and the modeling of the structure affect the seismic overstrength of structures. The relationship between actual mean strength and the minimum specified strength of concrete and structural steel is also presented. The paper identifies which concrete and steel structures are generally sized for earthquake loads and which are generally sized for other factors, e.g., tornado missiles, loss of coolant accident pressure loads, equipment laydown loads and radiation shielding. The results of a study evaluating the mean ultimate capacity of a pressurized water reactor containment are presented to show that in terms of a ground motion, the seismic capacity may be four to five times the design safe shutdown earthquake level

  1. Spatial correction factors for YALINA Booster facility loaded with medium and low enriched fuels

    International Nuclear Information System (INIS)

    Talamo, A.; Gohar, Y.; Bournos, V.; Fokov, Y.; Kiyavitskaya, H.; Routkovskaya, C.

    2012-01-01

    The Bell and Glasstone spatial correction factor is used in analyses of subcritical assemblies to correct the experimental reactivity as function of the detector position. Besides the detector position, several other parameters affect the correction factor: the energy weighting function of the detector, the detector size, the energy-angle distribution of source neutrons, and the reactivity of the subcritical assembly. This work focuses on the dependency of the correction factor on the detector material and it investigates the YALINA Booster subcritical assembly loaded with medium (36%) and low (10%) enriched fuels. (authors)

  2. Spatial correction factors for YALINA Booster facility loaded with medium and low enriched fuels

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, A.; Gohar, Y. [Argonne National Laboratory, 9700 S. Cass Ave, Argonne, IL 60439 (United States); Bournos, V.; Fokov, Y.; Kiyavitskaya, H.; Routkovskaya, C. [Joint Inst. for Power and Nuclear Research-Sosny, 99 Academician A.K.Krasin Str, Minsk 220109 (Belarus)

    2012-07-01

    The Bell and Glasstone spatial correction factor is used in analyses of subcritical assemblies to correct the experimental reactivity as function of the detector position. Besides the detector position, several other parameters affect the correction factor: the energy weighting function of the detector, the detector size, the energy-angle distribution of source neutrons, and the reactivity of the subcritical assembly. This work focuses on the dependency of the correction factor on the detector material and it investigates the YALINA Booster subcritical assembly loaded with medium (36%) and low (10%) enriched fuels. (authors)

  3. A load factor based mean-variance analysis for fuel diversification

    Energy Technology Data Exchange (ETDEWEB)

    Gotham, Douglas; Preckel, Paul; Ruangpattana, Suriya [State Utility Forecasting Group, Purdue University, West Lafayette, IN (United States); Muthuraman, Kumar [McCombs School of Business, University of Texas, Austin, TX (United States); Rardin, Ronald [Department of Industrial Engineering, University of Arkansas, Fayetteville, AR (United States)

    2009-03-15

    Fuel diversification implies the selection of a mix of generation technologies for long-term electricity generation. The goal is to strike a good balance between reduced costs and reduced risk. The method of analysis that has been advocated and adopted for such studies is the mean-variance portfolio analysis pioneered by Markowitz (Markowitz, H., 1952. Portfolio selection. Journal of Finance 7(1) 77-91). However the standard mean-variance methodology, does not account for the ability of various fuels/technologies to adapt to varying loads. Such analysis often provides results that are easily dismissed by regulators and practitioners as unacceptable, since load cycles play critical roles in fuel selection. To account for such issues and still retain the convenience and elegance of the mean-variance approach, we propose a variant of the mean-variance analysis using the decomposition of the load into various types and utilizing the load factors of each load type. We also illustrate the approach using data for the state of Indiana and demonstrate the ability of the model in providing useful insights. (author)

  4. An examination of vehicles at the brake-chassis test bed in the range of the partial engine load

    Directory of Open Access Journals (Sweden)

    Paweł MARZEC

    2017-06-01

    Full Text Available The performance of a ZI engine is presented in the paper, as well as a project involving a device for applying a partial load in the performed examinations of a brakechassis test bed. The device was prepared for an Opel Astra and enabled the determination of exterior characteristics of the engine for different values of the engine load. The indicating pressure sensor and the angle marker on the crankshaft allowed for the recording of the indicating pressure obtained at different values of the load. The analysis of heat evolution in the process of burning, based on the registered results of the measurements at the brake-chassis test bed, has also been included in the presentation.

  5. In Situ Loading of Basic Fibroblast Growth Factor Within Porous Silica Nanoparticles for a Prolonged Release

    Directory of Open Access Journals (Sweden)

    Postovit Lynne-Marie

    2009-01-01

    Full Text Available Abstract Basic fibroblast growth factor (bFGF, a protein, plays a key role in wound healing and blood vessel regeneration. However, bFGF is easily degraded in biologic systems. Mesoporous silica nanoparticles (MSNs with well-tailored porous structure have been used for hosting guest molecules for drug delivery. Here, we report an in situ route to load bFGF in MSNs for a prolonged release. The average diameter (d of bFGF-loaded MSNs is 57 ± 8 nm produced by a water-in-oil microemulsion method. The in vitro releasing profile of bFGF from MSNs in phosphate buffer saline has been monitored for 20 days through a colorimetric enzyme linked immunosorbent assay. The loading efficiency of bFGF in MSNs is estimated at 72.5 ± 3%. In addition, the cytotoxicity test indicates that the MSNs are not toxic, even at a concentration of 50 μg/mL. It is expected that the in situ loading method makes the MSNs a new delivery system to deliver protein drugs, e.g. growth factors, to help blood vessel regeneration and potentiate greater angiogenesis.

  6. Reduced mandibular range of motion in Duchenne muscular dystrophy : Predictive factors

    NARCIS (Netherlands)

    van Bruggen, H. W.; Van Den Engel-Hoek, L.; Steenks, M. H.; Bronkhorst, E. M.; Creugers, N. H J; de Groot, I. J M; Kalaykova, S. I.

    2015-01-01

    Patients with Duchenne muscular dystrophy (DMD) experience negative effects upon feeding and oral health. We aimed to determine whether the mandibular range of motion in DMD is impaired and to explore predictive factors for the active maximum mouth opening (aMMO). 23 patients with DMD (mean age 16·7

  7. Surface water acidification and critical loads: exploring the F-factor

    Directory of Open Access Journals (Sweden)

    K. Bishop

    2009-11-01

    Full Text Available As acid deposition decreases, uncertainties in methods for calculating critical loads become more important when judgements have to be made about whether or not further emission reductions are needed. An important aspect of one type of model that has been used to calculate surface water critical loads is the empirical F-factor which estimates the degree to which acid deposition is neutralised before it reaches a lake at any particular point in time relative to the pre-industrial, steady-state water chemistry conditions.

    In this paper we will examine how well the empirical F-functions are able to estimate pre-industrial lake chemistry as lake chemistry changes during different phases of acidification and recovery. To accomplish this, we use the dynamic, process-oriented biogeochemical model SAFE to generate a plausible time series of annual runoff chemistry for ca. 140 Swedish catchments between 1800 and 2100. These annual hydrochemistry data are then used to generate empirical F-factors that are compared to the "actual" F-factor seen in the SAFE data for each lake and year in the time series. The dynamics of the F-factor as catchments acidify, and then recover are not widely recognised.

    Our results suggest that the F-factor approach worked best during the acidification phase when soil processes buffer incoming acidity. However, the empirical functions for estimating F from contemporary lake chemistry are not well suited to the recovery phase when the F-factor turns negative due to recovery processes in the soil. This happens when acid deposition has depleted the soil store of BC, and then acid deposition declines, reducing the leaching of base cations to levels below those in the pre-industrial era. An estimate of critical load from water chemistry during recovery and empirical F functions would therefore result in critical loads that are too low. Therefore, the empirical estimates of the F-factor are a significant source of

  8. Effect of Loads and Other Key Factors on Oil-Transformer Ageing: Sustainability Benefits and Challenges

    Directory of Open Access Journals (Sweden)

    Radu Godina

    2015-10-01

    Full Text Available Transformers are one of the more expensive pieces of equipment found in a distribution network. The transformer’s role has not changed over the last decades. With simple construction and at the same time mechanically robust, they offer long term service that on average can reach half a century. Today, with the ongoing trend to supply a growing number of non-linear loads along with the notion of distributed generation (DG, a new challenge has arisen in terms of transformer sustainability, with one of the possible consequences being accelerated ageing. In this paper we carefully review the existing studies in the literature of the effect of loads and other key factors on oil-transformer ageing. The state-of-the-art is reviewed, each factor is analysed in detail, and in the end a smart transformer protection method is sought in order to monitor and protect it from upcoming challenges.

  9. An exact model for airline flight network optimization based on transport momentum and aircraft load factor

    Directory of Open Access Journals (Sweden)

    Daniel Jorge Caetano

    2017-12-01

    Full Text Available The problem of airline flight network optimization can be split into subproblems such as Schedule Generation (SG and Fleet Assignment (FA, solved in consecutive steps or in an integrated way, usually based on monetary costs and revenue forecasts. A linear pro­gramming model to solve SG and FA in an integrated way is presented, but with an al­ternative approach based on transport momentum and aircraft load factor. This alterna­tive approach relies on demand forecast and allows obtaining solutions considering min­imum average load factors. Results of the proposed model applications to instances of a regional Brazilian airline are presented. The comparison of the schedules generated by the proposed approach against those obtained by applying a model based on mone­tary costs and revenue forecasts demonstrates the validity of this alternative approach for airlines network planning.

  10. Assessment of vehicular live load and load factors for design of short-span bridges according to the new Egyptian Code

    Directory of Open Access Journals (Sweden)

    Hatem M. Seliem

    2015-04-01

    The study shows that concrete box-girders designed according to ECP-201:2012 and ECP-201:2003 using the ultimate limit state method yield almost the same demand. Despite the increase in the VLL of ECP-201:2012, and consequently the live load forces, concrete I-shaped girder bridges will be subjected to less total factored internal forces in comparison to ECP-201:2003 This is attributed to the interaction between the live to dead loads ratio and the load combinations. Design of composite steel plate girder bridges according to ECP-201:2012 using the allowable stress design method yields over designed sections.

  11. Evaluation on the Effect of Load Follow Controller's Weighting Factors

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Keuk Jong; Lee, Jae Gon [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    there are several important physical effects that limit the possibilities of power variations in NPPs. Some major effects are moderator and xenon effect. Moderator effect is relation with moderator density change and xenon effect is relation with the concentration change of Xe-135 which could affect axial power shape. These effects are more significant with large magnitudes of power variations and they are considered as major disturbances at the aspect of control method. Due to the above physical effects, it is necessary to carefully change nuclear power considering power distribution change in the core. So, when nuclear plants are required to operate on load variation mode, we could control not only reactor power but also power distribution. Generally, power distribution is controlled by reactor operators who have enough experience, whereas reactor power is automatically controlled by automatic controllers. So, it is necessary to design an automatic controller that controls both reactor power and power distribution for frequent load following operation. Korea Hydro and Nuclear Power Co., LTD (KHNP) has been developing automatic load follow controller as a part of Advanced Power Reactor Plus (APR+) development. The developing controller is composed of three algorithms which could control reactor power and axial power shape. This paper aimed to evaluate the effect of the controller’s weighting factors. So, in this paper, we identify the meaning of the weighting factors and the controlled output weighting factors are selected among them. In this study, the effect of output weighting factors is analyzed. According to the simulation results, it is recommended that the weighting factor of power be between 200 and 400 and that of ASI be between 200 and 600. In the near future, based on the study, optimization of power and ASI weighting factors will be performed at the same time.

  12. Factors Affecting Home Ranges of Red Foxes in Ikh Nart Nature Reserve, Mongolia

    Directory of Open Access Journals (Sweden)

    Tserendorj Munkhzul

    2012-12-01

    Full Text Available Changes in red fox home range size in relation to environmental and intrinsic factors were studied using radio-telemetry during 2006–2008 in Ikh Nart Nature Reserve, southeastern Mongolia. We captured a total of 12 red foxes (8 females and 4 males and fi tted them with VHF radio-collars. Marked animals were tracked up to fi ve times a week to estimate home ranges. We also trapped small mammal and insects in different biotopes for 3 years to estimate relative abundance of prey. Our results showed that mean individual home range sizes varied widely and differed among years. There was variation in home ranges between adults versus juveniles, but no signifi cant difference was found between males versus females. In addition, mean home range size did not differ seasonally for pooled years. Variation in home ranges was best explained by a model that included covariates of year and age. We suggest that spatiotemporal changes in resource availability across years infl uenced home range dynamics of red foxes in our study.

  13. Determination of the usage factor of components after cyclic loading using high-resolution microstructural investigations

    International Nuclear Information System (INIS)

    Seibold, A.; Scheibe, A.; Assmann, H.D.

    1989-01-01

    The usage factor can be derived from the quantification of the structure changes and the allocation of the microstructural state to the fatigue curves of the component materials. Using the example of the low alloy fine grain structural steel 20 Mn Mo Ni 5 5 (annealed structure), the relationship between micro-structure and the number of load cycles is shown in the form of a calibration curve. By high resolution structural investigation, the usage factor can be determined to n = N/N B ≅ 0.5 under given vibration stress. Only a small volume sample is required for the electron microscope examination. (orig./DG) [de

  14. The dependence of the nuclear charge form factor on short range correlations and surface fluctuation effects

    International Nuclear Information System (INIS)

    Massen, S. E.; Garistov, V. P.; Grypeos, M. E.

    1996-01-01

    The effects of nuclear surface fluctuations on harmonic oscillator elastic charge form factor of light nuclei are investigated, simultaneously approximating the short-range correlations through a Jastrow correlation factor. Inclusion of the surface fluctuation effects within this description, by truncating the cluster expansion at the two-body part, is found to improve somewhat the fit to the elastic charge form-factor of 16 O and 40 Ca. However, the convergence of the cluster expansion is expected to deteriorate. An additional finding is that surface-fluctuation correlations produce a drastic change in the asymptotic behaviour of the point-proton form-factor, which now falls off quite slowly (i.e. as const.q -4 ) at large values of the momentum transfer q

  15. Field Study of Live Load Distribution Factors and Dynamic Load Allowance on Reinforced Concrete T-Beam Bridges

    National Research Council Canada - National Science Library

    Trimble, Matthew

    2003-01-01

    .... The vehicle under consideration in this study was a U.S. Army Palletized Loading System (PLS) military vehicle. Results from this evaluation were compared to those obtained from a civilian dump truck owned by the Virginia Department of Transportation...

  16. Dutch monitor on stress and physical load: risk factors, consequences, and preventive action.

    Science.gov (United States)

    Houtman, I L; Goudswaard, A; Dhondt, S; van der Grinten, M P; Hildebrandt, V H; van der Poel, E G

    1998-02-01

    Due to recent changes in legislation on occupational health and safety, a national monitor on stress and physical load was developed in The Netherlands to monitor (a) risks and consequences of stress and physical load at work, (b) preventive actions in companies to reduce these risks, and (c) organisational and environmental variables that facilitate preventive actions. Information was gathered from employers, employees, and employees' representatives. The monitor was used with a nationally representative sample of companies in industry, wholesale trade, and banking and finance, 782 companies in total. The information from the employees, aggregated at the company level, was not found to be correlated with that from the employer from the same companies. Although many employers do recognise risk factors for both physical load and stress as a problem they often seem to underestimate the problem when compared with employees or their representatives. This is particularly the case for psychosocial risk factors. Also, the perception of outcome measures, especially employers who consider emotional exhaustion to be work related, were fewer than the employees' representatives of the same organisation. Preventive measures on physical load are much more popular than measures against stress. It is the responsibility of the employer to take more preventive action of all kinds. They need to recognise risk factors as problems and health outcomes to be related to work. Employees of larger companies should participate with employers to consider effective measures, and more use should be made of support at branch level. For specific preventive measures, specific predictors emerged. Except for measures to prevent work stress, information from employees did not sufficiently contribute to the initiation of preventive measures in the workplace.

  17. Structure factor of 36Ar and long range pair-potential properties

    International Nuclear Information System (INIS)

    Barocchi, F.; Chieux, P.; Fredrikze, H.; Magli, R.

    1992-01-01

    Recent diffraction data on low density Ar have been analyzed with the aim of determining the low k behaviour of the structure factor and from that the long range dipole-dipole interaction strength. The results are compared with the presently best known estimates of the van der Waals C 6 coefficient and with a previous analysis of neutron diffraction data on liquid Ar. (orig.)

  18. High Resolution and Large Dynamic Range Resonant Pressure Sensor Based on Q-Factor Measurement

    Science.gov (United States)

    Gutierrez, Roman C. (Inventor); Stell, Christopher B. (Inventor); Tang, Tony K. (Inventor); Vorperian, Vatche (Inventor); Wilcox, Jaroslava (Inventor); Shcheglov, Kirill (Inventor); Kaiser, William J. (Inventor)

    2000-01-01

    A pressure sensor has a high degree of accuracy over a wide range of pressures. Using a pressure sensor relying upon resonant oscillations to determine pressure, a driving circuit drives such a pressure sensor at resonance and tracks resonant frequency and amplitude shifts with changes in pressure. Pressure changes affect the Q-factor of the resonating portion of the pressure sensor. Such Q-factor changes are detected by the driving/sensing circuit which in turn tracks the changes in resonant frequency to maintain the pressure sensor at resonance. Changes in the Q-factor are reflected in changes of amplitude of the resonating pressure sensor. In response, upon sensing the changes in the amplitude, the driving circuit changes the force or strength of the electrostatic driving signal to maintain the resonator at constant amplitude. The amplitude of the driving signals become a direct measure of the changes in pressure as the operating characteristics of the resonator give rise to a linear response curve for the amplitude of the driving signal. Pressure change resolution is on the order of 10(exp -6) torr over a range spanning from 7,600 torr to 10(exp -6) torr. No temperature compensation for the pressure sensor of the present invention is foreseen. Power requirements for the pressure sensor are generally minimal due to the low-loss mechanical design of the resonating pressure sensor and the simple control electronics.

  19. Stress-intensity factors for cracks emanating from the loaded fastener hole

    Science.gov (United States)

    Shivakumar, V.; Hsu, Y. C.

    1977-01-01

    Using a series approach and the Muskhelishvili formulation in the two-dimensional theory of elasticity, stress-intensity factors K are derived for problems in which cracks emanate radially from the boundary of an arbitrarily loaded internal circular hole in an infinite plate. Numerical values are obtained for K(I) and K(II) for radial cracks from a hole containing a loose-fitted pin or rivet that is pulled perpendicular to the crack direction in the plane of the plate. The method is a general one for determining K for a set of symmetrically emanating radial cracks for a variety of concentrated or distributed tractions on the circular hole.

  20. A Wide Range of 3243A>G/tRNALeu(UUR) (MELAS) Mutation Loads May Segregate in Offspring through the Female Germline Bottleneck

    Science.gov (United States)

    Pallotti, Francesco; Binelli, Giorgio; Fabbri, Raffaella; Valentino, Maria L.; Vicenti, Rossella; Macciocca, Maria; Cevoli, Sabina; Baruzzi, Agostino; DiMauro, Salvatore; Carelli, Valerio

    2014-01-01

    Segregation of mutant mtDNA in human tissues and through the germline is debated, with no consensus about the nature and size of the bottleneck hypothesized to explain rapid generational shifts in mutant loads. We investigated two maternal lineages with an apparently different inheritance pattern of the same pathogenic mtDNA 3243A>G/tRNALeu(UUR) (MELAS) mutation. We collected blood cells, muscle biopsies, urinary epithelium and hair follicles from 20 individuals, as well as oocytes and an ovarian biopsy from one female mutation carrier, all belonging to the two maternal lineages to assess mutant mtDNA load, and calculated the theoretical germline bottleneck size (number of segregating units). We also evaluated “mother-to-offspring” segregations from the literature, for which heteroplasmy assessment was available in at least three siblings besides the proband. Our results showed that mutation load was prevalent in skeletal muscle and urinary epithelium, whereas in blood cells there was an inverse correlation with age, as previously reported. The histoenzymatic staining of the ovarian biopsy failed to show any cytochrome-c-oxidase defective oocyte. Analysis of four oocytes and one offspring from the same unaffected mother of the first family showed intermediate heteroplasmic mutant loads (10% to 75%), whereas very skewed loads of mutant mtDNA (0% or 81%) were detected in five offspring of another unaffected mother from the second family. Bottleneck size was 89 segregating units for the first mother and 84 for the second. This was remarkably close to 88, the number of “segregating units” in the “mother-to-offspring” segregations retrieved from literature. In conclusion, a wide range of mutant loads may be found in offspring tissues and oocytes, resulting from a similar theoretical bottleneck size. PMID:24805791

  1. Impact of ecological and social factors on ranging in western gorillas.

    Science.gov (United States)

    Doran-Sheehy, Diane M; Greer, David; Mongo, Patrice; Schwindt, Dylan

    2004-10-01

    We examined the influence of ecological (diet, swamp use, and rainfall) and social (intergroup interaction rate) factors on ranging behavior in one group of western gorillas (Gorilla gorilla gorilla) during a 16-month study. Relative to mountain gorillas, western gorillas live in habitats with reduced herb densities, more readily available fruit (from seasonal and rare fruit trees), and, at some sites, localized large open clearings (swamps and "bais"). Ranging behavior reflects these ecological differences. The daily path length (DPL) of western gorillas was longer (mean=2,014 m) than that of mountain gorillas, and was largely related to fruit acquisition. Swamp use occurred frequently (27% of days) and incurred a 50% increase in DPL, and 77% of the variation in monthly frequency of swamp use was explained by ripe fruit availability within the swamp, and not by the absence of resources outside the swamp. The annual home-range size was 15.4 km2. The western gorilla group foraged in larger areas each month, and reused them more frequently and consistently through time compared to mountain gorillas. In contrast to mountain gorillas, intergroup encounters occurred at least four times more frequently, were usually calm rather than aggressive, and had no consistent effect on DPL or monthly range size for one group of western gorillas. High genetic relatedness among at least some neighboring males [Bradley et al., Current Biology, in press] may help to explain these results, and raises intriguing questions about western gorilla social relationships.

  2. Quality Factor Effect on the Wireless Range of Microstrip Patch Antenna Strain Sensors

    Science.gov (United States)

    Daliri, Ali; Galehdar, Amir; Rowe, Wayne S. T.; John, Sabu; Wang, Chun H.; Ghorbani, Kamran

    2014-01-01

    Recently introduced passive wireless strain sensors based on microstrip patch antennas have shown great potential for reliable health and usage monitoring in aerospace and civil industries. However, the wireless interrogation range of these sensors is limited to few centimeters, which restricts their practical application. This paper presents an investigation on the effect of circular microstrip patch antenna (CMPA) design on the quality factor and the maximum practical wireless reading range of the sensor. The results reveal that by using appropriate substrate materials the interrogation distance of the CMPA sensor can be increased four-fold, from the previously reported 5 to 20 cm, thus improving considerably the viability of this type of wireless sensors for strain measurement and damage detection. PMID:24451457

  3. Quality Factor Effect on the Wireless Range of Microstrip Patch Antenna Strain Sensors

    Directory of Open Access Journals (Sweden)

    Ali Daliri

    2014-01-01

    Full Text Available Recently introduced passive wireless strain sensors based on microstrip patch antennas have shown great potential for reliable health and usage monitoring in aerospace and civil industries. However, the wireless interrogation range of these sensors is limited to few centimeters, which restricts their practical application. This paper presents an investigation on the effect of circular microstrip patch antenna (CMPA design on the quality factor and the maximum practical wireless reading range of the sensor. The results reveal that by using appropriate substrate materials the interrogation distance of the CMPA sensor can be increased four-fold, from the previously reported 5 to 20 cm, thus improving considerably the viability of this type of wireless sensors for strain measurement and damage detection.

  4. Structure factor of polymers interacting via a short range repulsive potential: Application to hairy wormlike micelles

    International Nuclear Information System (INIS)

    Massiera, Gladys; Ramos, Laurence; Ligoure, Christian; Pitard, Estelle

    2003-01-01

    We use the random phase approximation to compute the structure factor S(q) of a solution of chains interacting through a soft and short range repulsive potential V. Above a threshold polymer concentration, whose magnitude is essentially controlled by the range of the potential, S(q) exhibits a peak whose position depends on the concentration. We take advantage of the close analogy between polymers and wormlike micelles and apply our model, using a Gaussian function for V, to quantitatively analyze experimental small angle neutron scattering profiles of solutions of hairy wormlike micelles. These samples, which consist in surfactant self-assembled flexible cylinders decorated by amphiphilic copolymer, provide indeed an appropriate experimental model system to study the structure of sterically interacting polymer solutions

  5. Factors controlling streambed coverage of Didymosphenia geminata in two regulated streams in the Colorado Front Range

    OpenAIRE

    Miller, Matthew P.; McKnight, Diane M.; Cullis, James D.; Greene, Alicia; Vietti, Kristin; Liptzin, Daniel

    2009-01-01

    Didymosphenia geminata is a stalk-forming freshwater diatom which was historically found primarily in oligotrophic lakes and streams, but has recently become a nuisance species in many lotic systems worldwide. In the last 5–8 years, D. geminata has become established in Boulder Creek and South Boulder Creek, two regulated montane streams in the Front Range of the Colorado Rocky Mountains. Factors that may influence the growth of D. geminata were monitored during the summer of 2006. D. geminat...

  6. The astrophysical S-factor for dd-reactions at keV-energy range

    International Nuclear Information System (INIS)

    Bystritskii, V.; Bystritsky, V.; Chaikovsky, S.

    2001-01-01

    The experimental results of measurements of the astrophysical S-factor for dd-reaction at keV-energy range collision energies using liner plasma technique are presented. The experiments were carried out at the high current generator of the Institute of High-Current Electronics in Tomsk, Russia. The measured values of the S-factors for the deuteron collision energies 1.80, 2.06 and 2.27 keV are S dd =(114±68), (64±30), (53±16) b x keV, respectively. The corresponding cross sections for dd-reactions, described as a product of the barrier factor and measured astrophysical S-factor, are σ dd n (E col =1.80 keV)=(4.3±2.6) x 10 -33 cm 2 ; σ dd n (E col =2.06 keV)=(9.8±4.6) x 10 -33 cm 2 ; σ dd n (E col =2.27 keV)=(2.1±0.6) x 10 -32 cm 2 . (orig.) [de

  7. The injury List of All Deficits (LOAD) Framework--conceptualizing the full range of deficits and adverse outcomes following injury and violence.

    Science.gov (United States)

    Lyons, Ronan A; Finch, Caroline F; McClure, Rod; van Beeck, Ed; Macey, Steven

    2010-09-01

    Over recent years, there has been increasing recognition that the burden of injuries and violence includes more than just the direct and indirect monetary costs associated with their medical outcomes. However, quantification of the total burden has been seriously hampered by lack of a framework for considering the range of outcomes which comprise the burden, poor identification of the outcomes and their imprecise measurement. This article proposes a new conceptual framework, the List of All Deficits (or LOAD) Framework, that has been developed from extensive expert discussion and consensus meetings to facilitate the measurement of the full burden of injuries and violence. The LOAD Framework recognises the multidimensional nature of injury burden across individual, family and societal domains. This classification of potential consequences of injury was built on the International Classification of Functioning concept of disability. Examples of empirical support for each consequence were obtained from the scientific literature. Determining the multidimensional injury burden requires the assessment and combination of 20 domains of potential consequences. The resulting LOAD Framework classification and concept diagram describes 12 groups of injury consequences for individuals, three for family and close friends and five for wider society. Understanding the extent of the negative implications (or deficits) of injury, through application of the LOAD Framework, is needed to put existing burden of injury studies into context and to highlight the inter-relationship between the direct and indirect burden of injury relative to other conditions.

  8. A New Control Method for a Bi-Directional Phase-Shift-Controlled DC-DC Converter with an Extended Load Range

    Directory of Open Access Journals (Sweden)

    Wenzheng Xu

    2017-10-01

    Full Text Available Phase-shifted converters are practically important to provide high conversion efficiencies through soft-switching techniques. However, the limitation on a resonant inductor current in the converters often leads to a non-fulfillment of the requirement of minimum load current. This paper presents a new power electronics control technique to enable the dual features of bi-directional power flow and an extended load range for soft-switching in phase-shift-controlled DC-DC converters. The proposed technique utilizes two identical full bridge converters and inverters in conjunction with a new control logic for gate-driving signals to facilitate both Zero Current Switching (ZCS and Zero Voltage Switching (ZVS in a single phase-shift-controlled DC-DC converter. The additional ZCS is designed for light load conditions at which the minimum load current cannot be attained. The bi-directional phase-shift-controlled DC-DC converter can implement the function of synchronous rectification. Its fast dynamic response allows for quick energy recovery during the regenerative braking of traction systems in electrified trains.

  9. An estimation of finger-tapping rates and load capacities and the effects of various factors.

    Science.gov (United States)

    Ekşioğlu, Mahmut; İşeri, Ali

    2015-06-01

    The aim of this study was to estimate the finger-tapping rates and finger load capacities of eight fingers (excluding thumbs) for a healthy adult population and investigate the effects of various factors on tapping rate. Finger-tapping rate, the total number of finger taps per unit of time, can be used as a design parameter of various products and also as a psychomotor test for evaluating patients with neurologic problems. A 1-min tapping task was performed by 148 participants with maximum volitional tempo for each of eight fingers. For each of the tapping tasks, the participant with the corresponding finger tapped the associated key in the standard position on the home row of a conventional keyboard for touch typing. The index and middle fingers were the fastest fingers for both hands, and little fingers the slowest. All dominant-hand fingers, except little finger, had higher tapping rates than the fastest finger of the nondominant hand. Tapping rate decreased with age and smokers tapped faster than nonsmokers. Tapping duration and exercise had also significant effect on tapping rate. Normative data of tapping rates and load capacities of eight fingers were estimated for the adult population. In designs of psychomotor tests that require the use of tapping rate or finger load capacity data, the effects of finger, age, smoking, and tapping duration need to be taken into account. The findings can be used for ergonomic designs requiring finger-tapping capacity and also as a reference in psychomotor tests. © 2015, Human Factors and Ergonomics Society.

  10. Reconfigurable Resonant Regulating Rectifier With Primary Equalization for Extended Coupling- and Loading-Range in Bio-Implant Wireless Power Transfer.

    Science.gov (United States)

    Li, Xing; Meng, Xiaodong; Tsui, Chi-Ying; Ki, Wing-Hung

    2015-12-01

    Wireless power transfer using reconfigurable resonant regulating (R(3)) rectification suffers from limited range in accommodating varying coupling and loading conditions. A primary-assisted regulation principle is proposed to mitigate these limitations, of which the amplitude of the rectifier input voltage on the secondary side is regulated by accordingly adjusting the voltage amplitude Veq on the primary side. A novel current-sensing method and calibration scheme track Veq on the primary side. A ramp generator simultaneously provides three clock signals for different modules. Both the primary equalizer and the R(3) rectifier are implemented as custom integrated circuits fabricated in a 0.35 μm CMOS process, with the global control implemented in FPGA. Measurements show that with the primary equalizer, the workable coupling and loading ranges are extended by 250% at 120 mW load and 300% at 1.2 cm coil distance compared to the same system without the primary equalizer. A maximum rectifier efficiency of 92.5% and a total system efficiency of 62.4% are demonstrated.

  11. ANALYSIS OF DESIGN RANGE FOR A STROKING SEAT ON A STROKING FLOOR TO MITIGATE BLAST LOADING EFFECTS

    Science.gov (United States)

    2017-05-16

    addition, due to the extreme range in the mobility and other operational requirements in the battlefield, there is also a need even for light tactical...Government or the DoA, and shall not be used for advertising or product endorsement purposes. REFERENCES [1] Bird, S., and Fairweather. C., "Recent...UNCLASSIFIED LIST OF SYMBOLS, ABBREVIATIONS, ACRONYMS ATD Anthropomorphic Test Device , or Dummy CAMEL Concept for Advanced Military Explosion-mitigating

  12. Impaired Fasting Glucose in Nondiabetic Range: Is It a Marker of Cardiovascular Risk Factor Clustering?

    Directory of Open Access Journals (Sweden)

    Giovanna Valentino

    2015-01-01

    Full Text Available Background. Impaired fasting glucose (IFG through the nondiabetic range (100–125 mg/dL is not considered in the cardiovascular (CV risk profile. Aim. To compare the clustering of CV risk factors (RFs in nondiabetic subjects with normal fasting glucose (NFG and IFG. Material and Methods. Cross-sectional study in 3739 nondiabetic subjects. Demographics, medical history, and CV risk factors were collected and lipid profile, fasting glucose levels (FBG, C-reactive protein (hsCRP, blood pressure (BP, anthropometric measurements, and aerobic capacity were determined. Results. 559 (15% subjects had IFG: they had a higher mean age, BMI, waist circumference, non-HDL cholesterol, BP, and hsCRP (p<0.0001 and lower HDL (p<0.001 and aerobic capacity (p<0.001. They also had a higher prevalence of hypertension (34% versus 25%; p<0.001, dyslipidemia (79% versus 74%; p<0.001, and obesity (29% versus 16%; p<0.001 and a higher Framingham risk score (8% versus 6%; p<0.001. The probability of presenting 3 or more CV RFs adjusted by age and gender was significantly higher in the top quintile of fasting glucose (≥98 mg/dL; OR = 2.02; 1.62–2.51. Conclusions. IFG in the nondiabetic range is associated with increased cardiovascular RF clustering.

  13. Management, morphological, and environmental factors influencing Douglas-fir bark furrows in the Oregon Coast Range

    Science.gov (United States)

    Sheridan, Christopher D.; Puettmann, Klaus J.; Huso, Manuela M.P.; Hagar, Joan C.; Falk, Kristen R.

    2013-01-01

    Many land managers in the Pacific Northwest have the goal of increasing late-successional forest structures. Despite the documented importance of Douglas-fir tree bark structure in forested ecosystems, little is known about factors influencing bark development and how foresters can manage development. This study investigated the relative importance of tree size, growth, environmental factors, and thinning on Douglas-fir bark furrow characteristics in the Oregon Coast Range. Bark furrow depth, area, and bark roughness were measured for Douglas-fir trees in young heavily thinned and unthinned sites and compared to older reference sites. We tested models for relationships between bark furrow response and thinning, tree diameter, diameter growth, and environmental factors. Separately, we compared bark responses measured on trees used by bark-foraging birds with trees with no observed usage. Tree diameter and diameter growth were the most important variables in predicting bark characteristics in young trees. Measured environmental variables were not strongly related to bark characteristics. Bark furrow characteristics in old trees were influenced by tree diameter and surrounding tree densities. Young trees used by bark foragers did not have different bark characteristics than unused trees. Efforts to enhance Douglas-fir bark characteristics should emphasize retention of larger diameter trees' growth enhancement.

  14. Seroprevalence and risk factors of Chlamydia abortus infection in free-ranging white yaks in China.

    Science.gov (United States)

    Qin, Si-Yuan; Huang, Si-Yang; Yin, Ming-Yang; Tan, Qi-Dong; Liu, Guang-Xue; Zhou, Dong-Hui; Zhu, Xing-Quan; Zhou, Ji-Zhang; Qian, Ai-Dong

    2015-01-20

    Chlamydia is gram-negative obligate bacteria which causes a wide variety of diseases in humans and animals. To date, there are a few reports about the seroprevalence of Chlamydia and the risk factors associated with Chlamydia infection in yaks in the world. In this study, 974 blood samples were collected from white yaks (Bos grunniens) in Tianzhu Tibetan Autonomous County, Gansu province, northwest China from June 2013 to April 2014. Antibodies against Chlamydia abortus were examined by the indirect hemagglutination (IHA) test, and 158 of 974 (16.22%) white yaks were seropositive for C. abortus antibodies at the cut-off of 1:16. The risk factors associated with seroprevalence were evaluated by a multivariate logistic regression analysis. Region, gender and age of white yak were left out of the final model, due to its insignificance in the logistic regression analysis (P > 0.05). However, season was considered as a major risk factor associated with C. abortus infection in white yaks. To our knowledge, this is the first survey of C. abortus seroprevalence in white yaks in China, which extends the host range for C. abortus and has important implications for public health and the local Tibetan economy.

  15. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    Energy Technology Data Exchange (ETDEWEB)

    Nandi, Samit K., E-mail: samitnandi1967@gmail.com [Department of Veterinary Surgery and Radiology, West Bengal University of Animal and Fishery Sciences, Kolkata (India); Kundu, Biswanath, E-mail: biswa_kundu@rediffmail.com [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India); Basu, Debabrata [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India)

    2013-04-01

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing.

  16. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    International Nuclear Information System (INIS)

    Nandi, Samit K.; Kundu, Biswanath; Basu, Debabrata

    2013-01-01

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing

  17. Switch Panel wear loading - a parametric study regarding governing train operational factors

    Science.gov (United States)

    Hiensch, E. J. M.; Burgelman, N.

    2017-09-01

    The acting forces and resulting material degradation at the running surfaces of wheels and rail are determined by vehicle, track, interface and operational characteristics. To effectively manage the experienced wear, plastic deformation and crack development at wheels and rail, the interaction between vehicle and track demands a system approach both in maintenance and in design. This requires insight into the impact of train operational parameters on rail- and wheel degradation, in particular at switches and crossings due to the complex dynamic behaviour of a railway vehicle at a turnout. A parametric study was carried out by means of vehicle-track simulations within the VAMPIRE® multibody simulation software, performing a sensitivity analysis regarding operational factors and their impact on expected switch panel wear loading. Additionally, theoretical concepts were cross-checked with operational practices by means of a case study in response to a dramatic change in lateral rail wear development at specific switches in Dutch track. Data from train operation, track maintenance and track inspection were analysed, providing further insight into the operational dependencies. From the simulations performed in this study, it was found that switch rail lateral wear loading at the diverging route of a 1:9 type turnout is significantly influenced by the level of wheel-rail friction and to a lesser extent by the direction of travel (facing or trailing). The influence of other investigated parameters, being vehicle speed, traction, gauge widening and track layout is found to be small. Findings from the case study further confirm the simulation outcome. This research clearly demonstrates the contribution flange lubrication can have in preventing abnormal lateral wear at locations where the wheel-rail interface is heavily loaded.

  18. Risk factors for decreased range of motion and poor outcomes in open periarticular elbow fractures.

    Science.gov (United States)

    Dickens, Jonathan F; Wilson, Kevin W; Tintle, Scott M; Heckert, Reed; Gordon, Wade T; D'Alleyrand, Jean-Claude G; Potter, Benjamin K

    2015-04-01

    The purpose of this study was to identify risk factors present at the time of injury that predict poor functional outcomes and heterotopic ossification (HO) in open periarticular elbow fractures. We performed a retrospective review of 136 combat-related open elbow fractures from 2003 to 2010. Patient demographics, injury characteristics, treatment variables, and complications were recorded. Functional outcomes were analyzed to determine range of motion (ROM) and Mayo Elbow Performance Score (MEPS). Secondary outcome measures included the development of HO, return to duty, and revision operation. At a median 2.7 years from injury the median MEPS was 67.8 (range 30-100) with an average ulnohumeral arc motion of 89°. Bipolar fractures, with periarticular fractures on both sides of the elbow and at least one side containing intra-articular extension, were independently associated with decreased ulnohumeral motion (p=0.02) and decreased MEPS (pROM included more severe osseous comminution (p=0.001), and increased time to definitive fixation (p=0.03) and HO (p=0.02). More severe soft tissue injury (Gustilo and Anderson fracture type, p=0.02), peripheral nerve injury (p=0.04), and HO (p=0.03) were independently associated with decreased MEPS. HO developed in 65% (89/136) of extremities and was associated with more severe Orthopaedic Trauma Association (OTA) fracture type (p=0.01) and escalating Gustilo and Anderson fracture classification (p=0.049). In the largest series of open elbow fractures, we identified risk factors that portend a poor clinical outcome and decreased ROM. Bipolar elbow fractures, which have not previously been associated with worse results, are particularly prone to decreased ROM and worse outcomes. Prognostic level IV. Published by Elsevier Ltd.

  19. Reduced mandibular range of motion in Duchenne Muscular Dystrophy: predictive factors.

    Science.gov (United States)

    van Bruggen, H W; Van Den Engel-Hoek, L; Steenks, M H; Bronkhorst, E M; Creugers, N H J; de Groot, I J M; Kalaykova, S I

    2015-06-01

    Patients with Duchenne muscular dystrophy (DMD) experience negative effects upon feeding and oral health. We aimed to determine whether the mandibular range of motion in DMD is impaired and to explore predictive factors for the active maximum mouth opening (aMMO). 23 patients with DMD (mean age 16.7 ± 7.7 years) and 23 controls were assessed using a questionnaire about mandibular function and impairments. All participants underwent a clinical examination of the masticatory system, including measurement of mandibular range of motion and variables related to mandibular movements. In all patients, quantitative ultrasound of the digastric muscle and the geniohyoid muscle and the motor function measure (MFM) scale were performed. The patients were divided into early and late ambulatory stage (AS), early non-ambulatory stage (ENAS) and late non-ambulatory stage (LNAS). All mandibular movements were reduced in the patient group (P < 0.001) compared to the controls. Reduction in the aMMO (<40 mm) was found in 26% of the total patient group. LNAS patients had significantly smaller mandibular movements compared to AS and ENAS (P < 0.05). Multiple linear regression analysis for aMMO revealed a positive correlation with the body height and disease progression, with MFM total score as the strongest independent risk factor (R(2) = 0.71). Mandibular movements in DMD are significantly reduced and become more hampered with loss of motor function, including the sitting position, arm function, and neck and head control. We suggest that measurement of the aMMO becomes a part of routine care of patients with DMD. © 2015 John Wiley & Sons Ltd.

  20. Process for improving the load factor of an electricity generating power station

    International Nuclear Information System (INIS)

    Rostaing, Michel.

    1974-01-01

    A description is given of a process for improving the load factor of an electricity generating power station feeding a supply network in which all or part of the power not required by the network during off-peak hours is used for producing hydrogen which is then stored. The stored hydrogen is then burned and the heat generated is employed for superheating the steam generated by the nuclear reactor of the power plant. This combustion is carried out permanently. The hydrogen is produced by water electrolysis. The oxygen also produced in this manner is used as a comburent in the combustion of the hydrogen. The reactor is of the pressurized water type [fr

  1. Stress intensity factors of eccentric cracks in bi-materials plate under mode I loading

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, A. E. [Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor (Malaysia)

    2015-05-15

    Bi-material plates were generally used to joint electronic devices or mechanical components requiring dissimilar materials to be attached. During services, mechanical failure can be occurred due to the formation of cracks at the interfacial joint or away from the centre. Generally, linear elastic fracture mechanics approach is used to characterize these cracks based on stress intensity factors (SIF). Based on the literature survey, the SIFs for the central cracks were easily available. However, the SIFs for eccentric cracks were difficult to obtain. Therefore, this paper presented the SIFs for eccentric cracks subjected to mode I tension loading. Three important parameters were used such as relative crack depth, a/L, relative offset distance, b/L and elastic mismatch, E{sub 1}/E{sub 2} or α. It was found that such parameters significantly affected the characteristic of SIFs and it was depend on the location of cracks.

  2. Assessment of Various Risk Factors for Success of Delayed and Immediate Loaded Dental Implants: A Retrospective Analysis.

    Science.gov (United States)

    Prasant, M C; Thukral, Rishi; Kumar, Sachin; Sadrani, Sannishth M; Baxi, Harsh; Shah, Aditi

    2016-10-01

    Ever since its introduction in 1977, a minimum of few months of period is required for osseointegration to take place after dental implant surgery. With the passage of time and advancements in the fields of dental implant, this healing period is getting smaller and smaller. Immediate loading of dental implants is becoming a very popular procedure in the recent time. Hence, we retrospectively analyzed the various risk factors for the failure of delayed and immediate loaded dental implants. In the present study, retrospective analysis of all the patients was done who underwent dental implant surgeries either by immediate loading procedure or by delayed loading procedures. All the patients were divided broadly into two groups with one group containing patients in which delayed loaded dental implants were placed while other consisted of patients in whom immediate loaded dental implants were placed. All the patients in whom follow-up records were missing and who had past medical history of any systemic diseases were excluded from the present study. Evaluation of associated possible risk factors was done by classifying the predictable factors as primary and secondary factors. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Kaplan-Meier survival analyses and chi-square test were used for assessment of level of significance. In delayed and immediate group of dental implants, mean age of the patients was 54.2 and 54.8 years respectively. Statistically significant results were obtained while comparing the clinical parameters of the dental implants in both the groups while demographic parameters showed nonsignificant correlation. Significant higher risk of dental implant failure is associated with immediate loaded dental implants. Tobacco smoking, shorter implant size, and other risk factors play a significant role in predicting the success and failure of dental implants. Delayed loaded dental implant placement should be preferred

  3. Fisher Information Based Meteorological Factors Introduction and Features Selection for Short-Term Load Forecasting

    Directory of Open Access Journals (Sweden)

    Shuping Cai

    2018-03-01

    Full Text Available Weather information is an important factor in short-term load forecasting (STLF. However, for a long time, more importance has always been attached to forecasting models instead of other processes such as the introduction of weather factors or feature selection for STLF. The main aim of this paper is to develop a novel methodology based on Fisher information for meteorological variables introduction and variable selection in STLF. Fisher information computation for one-dimensional and multidimensional weather variables is first described, and then the introduction of meteorological factors and variables selection for STLF models are discussed in detail. On this basis, different forecasting models with the proposed methodology are established. The proposed methodology is implemented on real data obtained from Electric Power Utility of Zhenjiang, Jiangsu Province, in southeast China. The results show the advantages of the proposed methodology in comparison with other traditional ones regarding prediction accuracy, and it has very good practical significance. Therefore, it can be used as a unified method for introducing weather variables into STLF models, and selecting their features.

  4. Human Factors Evaluation of the Modular Lightweight Load-Carrying Equipment (MOLLE) System

    National Research Council Canada - National Science Library

    Sampson, James

    2001-01-01

    .... The FEA was used in drafting a new user requirements document and initiating the development of a modular load-carrying system which ultimately became known as the Modular Lightweight Load-carrying Equipment (MOLLE...

  5. Investigating the Effects of Loading Factors on the In Vitro Pharmaceutical Performance of Mesoporous Materials as Drug Carriers for Ibuprofen

    Directory of Open Access Journals (Sweden)

    Junmin Lai

    2017-02-01

    Full Text Available The aim of the study was to investigate the effects of the loading factors, i.e., the initial drug loading concentration and the ratio of the drug to carriers, on the in vitro pharmaceutical performance of drug-loaded mesoporous systems. Ibuprofen (IBU was used as a model drug, and two non-ordered mesoporous materials of commercial silica Syloid® 244FP (S244FP and Neusilin® US2 (NS2 were selected in the study. The IBU-loaded mesoporous samples were prepared by a solvent immersion method with a rotary evaporation drying technique and characterized by polarized light microscopy (PLM, Fourier transform infrared (FTIR spectroscopy, X-ray powder diffraction (XRPD and differential scanning calorimetry (DSC. Dissolution experiments were performed in simulated gastric media at 37 °C under non-sink conditions. The concentration of IBU in solution was determined by HPLC. The study showed that the dissolution rate of IBU can be improved significantly using the mesoporous S224FP carriers due to the conversion of crystalline IBU into the amorphous form. Both of the loading factors affected the IBU dissolution kinetics. Due to the molecular interaction between the IBU and NS2 carriers, the loading factors had little effects on the drug release kinetics with incomplete drug desorption recovery and insignificant dissolution enhancement. Care and extensive evaluation must therefore be taken when mesoporous materials are chosen as carrier delivery systems.

  6. Relation of Adiponectin to Glucose Tolerance Status, Adiposity, and Cardiovascular Risk Factor Load

    Directory of Open Access Journals (Sweden)

    N. Wolfson

    2012-01-01

    Full Text Available Objective. Adiponectin has anti-atherogenic and anti-inflammatory properties. We investigated the influence of adiponectin on glucose tolerance status, adiposity and cardiovascular risk factors (CVRFs. Design and Patients. Study consisted of 107 subjects: 55 with normal glucose tolerance (NGT and 52 with impaired glucose regulation (IGR who were divided into two groups: 24 subjects with impaired fasting glucose (IFG Group and 28 patients with type 2 diabetes mellitus (DM Group. In additional analysis, study participants were divided into two groups, according to CVRFs: low and high risk. Measurements: Patients were evaluated for glucose, HbA1C, insulin, lipids, CRP, HOMA-IR and adiponectin. Measurements. Patients were evaluated for glucose, HbA1C, insulin, lipids, CRP, HOMA-IR and adiponectin. Results. Adiponectin was significantly higher in NGT group than in IFG (=0.003 and DM (=0.01 groups. Adiponectin was significantly, positively associated with HDL and inversely associated with glucose, HbA1c, ALT, AST, TG, HOMA-IR. Patients with higher CVRFs load have lesser adiponectin compared to patients with low cardiovascular risk <0.0001. Adiponectin was inversely associated with the number of risk factors (=−0.430, =0.0001. Conclusions. Circulating adiponectin was significantly lower in subjects with different degree of IGR compared to subjects with normal glucose homeostasis. Adiponectin was significantly lower in high risk group than low risk group and decreased concurrently with increased number of CVRFs.

  7. Antiretroviral treatment adherence as a mediating factor between psychosocial variables and HIV viral load.

    Science.gov (United States)

    Attonito, Jennifer; Dévieux, Jessy G; Lerner, Brenda D G; Hospital, Michelle M; Rosenberg, Rhonda

    2014-01-01

    Psychosocial factors may directly impact HIV health measures such as viral load (VL) whether or not patients are taking antiretroviral treatment (ART) consistently. Structural equation modeling plus Baron and Kenny's (1986) four-step approach were used to test a mediated model predicting VL among 246 HIV-infected adults who were on ART. Exogenous variables were social support, barriers to adherence, and stress. Moderators were alcohol use, marijuana use, and neurocognitive impairment. A small positive association between marijuana use and ART adherence approached significance. Only barriers to adherence predicted a decrease in adherence rates and an increase in VL. No other factors were significantly associated with either VL or adherence, and no interaction effects between exogenous variables and moderators were identified. The association between barriers to adherence and VL was partially mediated by ART adherence. Findings provide modest support for a direct link between psychosocial variables and a virologic response to ART. Copyright © 2014 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  8. Factors affecting seasonal habitat use, and predicted range of two tropical deer in Indonesian rainforest

    Science.gov (United States)

    Rahman, Dede Aulia; Gonzalez, Georges; Haryono, Mohammad; Muhtarom, Aom; Firdaus, Asep Yayus; Aulagnier, Stéphane

    2017-07-01

    There is an urgent recognized need for conservation of tropical forest deer. In order to identify some environmental factors affecting conservation, we analyzed the seasonal habitat use of two Indonesian deer species, Axis kuhlii in Bawean Island and Muntiacus muntjak in south-western Java Island, in response to several physical, climatic, biological, and anthropogenic variables. Camera trapping was performed in different habitat types during both wet and dry season to record these elusive species. The highest number of photographs was recorded in secondary forest and during the dry season for both Bawean deer and red muntjac. In models, anthropogenic and climatic variables were the main predictors of habitat use. Distances to cultivated area and to settlement were the most important for A. kuhlii in the dry season. Distances to cultivated area and annual rainfall were significant for M. muntjak in both seasons. Then we modelled their predictive range using Maximum entropy modelling (Maxent). We concluded that forest landscape is the fundamental scale for deer management, and that secondary forests are potentially important landscape elements for deer conservation. Important areas for conservation were identified accounting of habitat transformation in both study areas.

  9. Influential Factors for Accurate Load Prediction in a Demand Response Context

    DEFF Research Database (Denmark)

    Wollsen, Morten Gill; Kjærgaard, Mikkel Baun; Jørgensen, Bo Nørregaard

    2016-01-01

    Accurate prediction of a buildings electricity load is crucial to respond to Demand Response events with an assessable load change. However, previous work on load prediction lacks to consider a wider set of possible data sources. In this paper we study different data scenarios to map the influence....... Next, the time of day that is being predicted greatly influence the prediction which is related to the weather pattern. By presenting these results we hope to improve the modeling of building loads and algorithms for Demand Response planning.......Accurate prediction of a buildings electricity load is crucial to respond to Demand Response events with an assessable load change. However, previous work on load prediction lacks to consider a wider set of possible data sources. In this paper we study different data scenarios to map the influence...

  10. Investigation of factors influencing the efficacy of electromagnetic shielding in X band frequency range

    Directory of Open Access Journals (Sweden)

    Vida Zaroushani

    2016-12-01

    Full Text Available Introduction: Due to the importance of engineering controls for prevention of microwave exposure, this study was conducted to design and constract a novel electromagnetic shielding and also to examine the factors influencing shielding efficacy in X band frequency range. Material and Method: This study used Resin Epoxy as matrix and nano-Nickel Oxide as filler to prepare the composite plates with three different thicknesses (2,4, and 6 mm and four different weight percentages (5,7,9 and 11. The fabricated composites characterized using X-ray diffraction and Field Emission Scanning Electron microscopy. Shielding effectiveness, percolation depth, and percolation threshold were measured using Vector Network Analyzers. Thermal Gravimetric Analysis was conducted to study the temperature influence on weight loss for fabricated composites. Result: A maximum shielding effectiveness value of 84.18% was obtained for the 11%-6mm composite at 8.01 GHz and the 7%-4mm composite exhibits a higher average of shielding effectiveness of 66.72% at X- band frequency range. The 4mm thickness was optimum and critical diameter for composite plates; and percolation depth was obtained greater than thickness of composites. However, increasing the nickel oxide content did not show noticeable effect on the shielding effectiveness. Thermal Gravimetric Analysis showed that the study shields were resistant to temperature up to 150 °C without experiencing weight loss. What is more, the results indicated that Nickel oxide Nano particles had desirable distribution and dispersion in epoxy matrix and percolation threshold was appeared in low content of nickel oxide nanoparticles. Conclusion: A novel electromagnetic shield using low thickness and few content of nanoparticle with noticeable efficacy was properly designed and constructed in the field of occupational health. In addition, this shield has low cost, easy to manufacture, resistance to wet/corrosion, and low weight. Epoxy

  11. The use of simulated rainfall to study the discharge process and the influence factors of urban surface runoff pollution loads.

    Science.gov (United States)

    Qinqin, Li; Qiao, Chen; Jiancai, Deng; Weiping, Hu

    2015-01-01

    An understanding of the characteristics of pollutants on impervious surfaces is essential to estimate pollution loads and to design methods to minimize the impacts of pollutants on the environment. In this study, simulated rainfall equipment was constructed to investigate the pollutant discharge process and the influence factors of urban surface runoff (USR). The results indicated that concentrations of total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and chemical oxygen demand (COD) appeared to be higher in the early period and then decreased gradually with rainfall duration until finally stabilized. The capacity and particle size of surface dust, rainfall intensity and urban surface slopes affected runoff pollution loads to a variable extent. The loads of TP, TN and COD showed a positive relationship with the surface dust capacity, whereas the maximum TSS load appeared when the surface dust was 0.0317 g·cm⁻². Smaller particle sizes (pollution carrying capacity of runoff, leading to higher pollution loads. Knowledge of the influence factors could assist in the management of USR pollution loads.

  12. A fully integrated, wide-load-range, high-power-conversion-efficiency switched capacitor DC-DC converter with adaptive bias comparator for ultra-low-power power management integrated circuit

    Science.gov (United States)

    Asano, Hiroki; Hirose, Tetsuya; Kojima, Yuta; Kuroki, Nobutaka; Numa, Masahiro

    2018-04-01

    In this paper, we present a wide-load-range switched-capacitor DC-DC buck converter with an adaptive bias comparator for ultra-low-power power management integrated circuit. The proposed converter is based on a conventional one and modified to operate in a wide load range by developing a load current monitor used in an adaptive bias comparator. Measurement results demonstrated that our proposed converter generates a 1.0 V output voltage from a 3.0 V input voltage at a load of up to 100 µA, which is 20 times higher than that of the conventional one. The power conversion efficiency was higher than 60% in the load range from 0.8 to 100 µA.

  13. Least Limiting Water Range and Load Bearing Capacity of Soil under Types of Tractor-Trailers for Mechanical Harvesting of Green Sugarcane

    Directory of Open Access Journals (Sweden)

    Antonio Higino Frederico Pereira

    2015-12-01

    Full Text Available ABSTRACT The expansion of the sugarcane industry in Brazil has intensified the mechanization of agriculture and caused effects on the soil physical quality. The purpose of this study was to evaluate the limiting water range and soil bearing capacity of a Latossolo Vermelho distroférrico típico (Rhodic Hapludox under the influence of different tractor-trailers used in mechanical sugarcane harvesting. The experiment was arranged in a randomized block design with five replications. The treatments consisted of green sugarcane harvesting with: harvester without trailer (T1; harvester with two trailers with a capacity of 10 Mg each (T2; harvester with trailer with a capacity of 20 Mg (T3 and harvester and truck with trailer with a capacity of 20 Mg (10 Mg per compartment (T4. The least limiting water range and soil bearing capacity were evaluated. The transport equipment to remove the harvested sugarcane from the field (trailer at harvest decreased the least limiting water range, reducing the structural soil quality. The truck trailer caused the greatest impact on the soil physical properties studied. The soil load bearing capacity was unaffected by the treatments, since the pressure of the harvester (T1 exceeded the pre-consolidation pressure of the soil.

  14. A Dynamic Multi-Level Factor Model with Long-Range Dependence

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre; Rodríguez-Caballero, Carlos Vladimir

    A dynamic multi-level factor model with stationary or nonstationary global and regional factors is proposed. In the model, persistence in global and regional common factors as well as innovations allows for the study of fractional cointegrating relationships. Estimation of global and regional...

  15. Nearshore hydrodynamics as loading and forcing factors for Escherichia coli contamination at an embayed beach

    Science.gov (United States)

    Ge, Zhongfu; Whitman, Richard L.; Nevers, Meredith B.; Phanikumar, Mantha S.; Byappanahalli, Muruleedhara N.

    2012-01-01

    Numerical simulations of the transport and fate of Escherichia coli were conducted at Chicago's 63rd Street Beach, an embayed beach that had the highest mean E. coli concentration among 23 similar Lake Michigan beaches during summer months of 2000-2005, in order to find the cause for the high bacterial contamination. The numerical model was based on the transport of E. coli by current circulation patterns in the embayment driven by longshore main currents and the loss of E. coli in the water column, taking settling as well as bacterial dark- and solar-related decay into account. Two E. coli loading scenarios were considered: one from the open boundary north of the embayment and the other from the shallow water near the beachfront. Simulations showed that the embayed beach behaves as a sink for E. coli in that it generally receives E. coli more efficiently than it releases them. This is a result of the significantly different hydrodynamic forcing factors between the inside of the embayment and the main coastal flow outside. The settled E. coli inside the embayment can be a potential source of contamination during subsequent sediment resuspension events, suggesting that deposition-resuspension cycles of E. coli have resulted in excessive bacterial contamination of beach water. A further hypothetical case with a breakwater shortened to half its original length, which was anticipated to enhance the current circulation in the embayment, showed a reduction in E. coli concentrations of nearly 20%.

  16. Evaluation of Dynamic Load Factors for a High-Speed Railway Truss Arch Bridge

    Directory of Open Access Journals (Sweden)

    Ding Youliang

    2016-01-01

    Full Text Available Studies on dynamic impact of high-speed trains on long-span bridges are important for the design and evaluation of high-speed railway bridges. The use of the dynamic load factor (DLF to account for the impact effect has been widely accepted in bridge engineering. Although the field monitoring studies are the most dependable way to study the actual DLF of the bridge, according to previous studies there are few field monitoring data on high-speed railway truss arch bridges. This paper presents an evaluation of DLF based on field monitoring and finite element simulation of Nanjing DaShengGuan Bridge, which is a high-speed railway truss arch bridge with the longest span throughout the world. The DLFs in different members of steel truss arch are measured using monitoring data and simulated using finite element model, respectively. The effects of lane position, number of train carriages, and speed of trains on DLF are further investigated. By using the accumulative probability function of the Generalized Extreme Value Distribution, the probability distribution model of DLF is proposed, based on which the standard value of DLF within 50-year return period is evaluated and compared with different bridge design codes.

  17. Clinical Factors and Viral Load Influencing Severity of Acute Hepatitis A

    Science.gov (United States)

    Lee, Hyun Woong; Chang, Dong-Yeop; Moon, Hong Ju; Chang, Hye Young; Shin, Eui-Cheol; Lee, June Sung; Kim, Kyung-Ah; Kim, Hyung Joon

    2015-01-01

    Background and Aims Clinical manifestations of hepatitis A virus (HAV) infection vary from mild to fulminant hepatic failure (FHF) in adults. We investigated the relationship between laboratory findings, including viral load, and clinical outcomes in patients with acute hepatitis A (AHA) and evaluated predictive factors for severe acute hepatitis (s-AH). Methods We analyzed the clinical manifestations of AHA in 770 patients. Patients with a prothrombin time (PT) of less than 40% of normal were classified as s-AH and included 4 patients with FHF, 11 patients with acute renal failure, and 3 patients with prolonged jaundice (n = 128). Other patients were defined as mild acute hepatitis (m-AH) (n = 642). Serum samples were obtained from 48 patients with acute hepatitis A. Among them, 20 with s-AH, and 28 with m-AH, were tested for HAV RNA titer. Results In a multivariate analysis, age (HR = 1.042, P = 0.041), peak creatinine (HR = 4.014, P = 0.001), bilirubin (HR = 1.153, P = 0.003), alanine aminotransferase (ALT) (HR = 1.001, Phepatitis A. PMID:26090677

  18. Clinical Factors and Viral Load Influencing Severity of Acute Hepatitis A.

    Science.gov (United States)

    Lee, Hyun Woong; Chang, Dong-Yeop; Moon, Hong Ju; Chang, Hye Young; Shin, Eui-Cheol; Lee, June Sung; Kim, Kyung-Ah; Kim, Hyung Joon

    2015-01-01

    Clinical manifestations of hepatitis A virus (HAV) infection vary from mild to fulminant hepatic failure (FHF) in adults. We investigated the relationship between laboratory findings, including viral load, and clinical outcomes in patients with acute hepatitis A (AHA) and evaluated predictive factors for severe acute hepatitis (s-AH). We analyzed the clinical manifestations of AHA in 770 patients. Patients with a prothrombin time (PT) of less than 40% of normal were classified as s-AH and included 4 patients with FHF, 11 patients with acute renal failure, and 3 patients with prolonged jaundice (n = 128). Other patients were defined as mild acute hepatitis (m-AH) (n = 642). Serum samples were obtained from 48 patients with acute hepatitis A. Among them, 20 with s-AH, and 28 with m-AH, were tested for HAV RNA titer. In a multivariate analysis, age (HR = 1.042, P = 0.041), peak creatinine (HR = 4.014, P = 0.001), bilirubin (HR = 1.153, P = 0.003), alanine aminotransferase (ALT) (HR = 1.001, P hepatitis A.

  19. Critical human-factors issues in nuclear-power regulation and a recommended comprehensive human-factors long-range plan. Executive summary

    International Nuclear Information System (INIS)

    Hopkins, C.O.; Snyder, H.L.; Price, H.E.; Hornick, R.J.; Mackie, R.R.; Smillie, R.J.; Sugarman, R.C.

    1982-08-01

    This comprehensive long-range human factors plan for nuclear reactor regulation was developed by a Study Group of the Human Factors Society, Inc. This Study Group was selected by the Executive Council of the Society to provide a balanced, experienced human factors perspective to the applications of human factors scientific and engineering knowledge to nuclear power generation. The report is presented in three volumes. Volume 1 contains an Executive Summary of the 18-month effort and its conclusions. Volume 2 summarizes all known nuclear-related human factors activities, evaluates these activities wherever adequate information is available, and describes the recommended long-range (10-year) plan for human factors in regulation. Volume 3 elaborates upon each of the human factors issues and areas of recommended human factors involvement contained in the plan, and discusses the logic that led to the recommendations

  20. Dutch monitor on stress and physical load : risk factors, consequences, and preventive action

    NARCIS (Netherlands)

    Houtman, I.L.D.; Goudswaard, A.; Dhondt, S.; Grinten, M.P. van der; Hildebrandt, V.H.; Poel, E.G.T. van der

    1998-01-01

    Objectives - Due to recent changes in legislation on occupational health and safety, a national monitor on stress and physical load was developed in The Netherlands to monitor (a) risks and consequences of stress and physical load at work, (b) preventive actions in companies to reduce these risks,

  1. Stress concentration factors for integral and pad reinforced nozzles in spherical pressure vessels subjected to radial load and moment

    International Nuclear Information System (INIS)

    Soliman, S.F.; Gill, S.S.

    1979-01-01

    Charts are presented giving the elastic stress concentration factors in spherical pressure vessels with pad and integral reinforcement for radial branches subjected to radial load and moment. The effect of all the geometrical parameters is discussed, including the limitations of thin shell theory on the validity of the results. (author)

  2. Reliability Analysis of Offshore Jacket Structures with Wave Load on Deck using the Model Correction Factor Method

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Friis-Hansen, P.; Nielsen, J.S.

    2006-01-01

    failure/collapse of jacket type platforms with wave in deck loads using the so-called Model Correction Factor Method (MCFM). A simple representative model for the RSR measure is developed and used in the MCFM technique. A realistic example is evaluated and it is seen that it is possible to perform...

  3. Resveratrol-Loaded Lipid Nanocarriers: Correlation between In Vitro Occlusion Factor and In Vivo Skin Hydrating Effect

    Directory of Open Access Journals (Sweden)

    Lucia Montenegro

    2017-12-01

    Full Text Available Lipid nanocarriers show occlusive properties that may be related to their ability to improve skin hydration. The aim of this work was to evaluate the relationship between in vitro occlusion factor and in vivo skin hydration for three types of lipid nanocarriers: nanoemulsions (NEs, solid lipid nanoparticles (SLNs and nanostructured lipid carriers (NLCs. These lipid nanocarriers were loaded with trans-resveratrol (RSV and incorporated in gel vehicles. In vitro occlusion factor was in the order SLNs > NLCs > NEs. Gels containing unloaded or RSV loaded lipid nanocarriers were applied on the back of a hand of 12 healthy volunteers twice a day for one week, recording skin hydration changes using the instrument Soft Plus. An increase of skin hydration was observed for all lipid nanocarriers (SLNs > NLCs > NEs. RSV loading into these nanocarriers did not affect in vitro and in vivo lipid nanocarriers effects. A linear relationship (r2 = 0.969 was observed between occlusion factor and in vivo increase of skin hydration. Therefore, the results of this study showed the feasibility of using the occlusion factor to predict in vivo skin hydration resulting from topical application of different lipid nanocarriers loading an active ingredient with no inherent hydrating activity.

  4. Session-RPE Method for Training Load Monitoring: Validity, Ecological Usefulness, and Influencing Factors

    Directory of Open Access Journals (Sweden)

    Monoem Haddad

    2017-11-01

    Full Text Available Purpose: The aim of this review is to (1 retrieve all data validating the Session-rating of perceived exertion (RPE-method using various criteria, (2 highlight the rationale of this method and its ecological usefulness, and (3 describe factors that can alter RPE and users of this method should take into consideration.Method: Search engines such as SPORTDiscus, PubMed, and Google Scholar databases in the English language between 2001 and 2016 were consulted for the validity and usefulness of the session-RPE method. Studies were considered for further analysis when they used the session-RPE method proposed by Foster et al. in 2001. Participants were athletes of any gender, age, or level of competition. Studies using languages other than English were excluded in the analysis of the validity and reliability of the session-RPE method. Other studies were examined to explain the rationale of the session-RPE method and the origin of RPE.Results: A total of 950 studies cited the Foster et al. study that proposed the session RPE-method. 36 studies have examined the validity and reliability of this proposed method using the modified CR-10.Conclusion: These studies confirmed the validity and good reliability and internal consistency of session-RPE method in several sports and physical activities with men and women of different age categories (children, adolescents, and adults among various expertise levels. This method could be used as “standing alone” method for training load (TL monitoring purposes though some recommend to combine it with other physiological parameters as heart rate.

  5. Transcription factor assisted loading and enhancer dynamics dictate the hepatic fasting response

    Science.gov (United States)

    Goldstein, Ido; Baek, Songjoon; Presman, Diego M.; Paakinaho, Ville; Swinstead, Erin E.; Hager, Gordon L.

    2017-01-01

    Fasting elicits transcriptional programs in hepatocytes leading to glucose and ketone production. This transcriptional program is regulated by many transcription factors (TFs). To understand how this complex network regulates the metabolic response to fasting, we aimed at isolating the enhancers and TFs dictating it. Measuring chromatin accessibility revealed that fasting massively reorganizes liver chromatin, exposing numerous fasting-induced enhancers. By utilizing computational methods in combination with dissecting enhancer features and TF cistromes, we implicated four key TFs regulating the fasting response: glucocorticoid receptor (GR), cAMP responsive element binding protein 1 (CREB1), peroxisome proliferator activated receptor alpha (PPARA), and CCAAT/enhancer binding protein beta (CEBPB). These TFs regulate fuel production by two distinctly operating modules, each controlling a separate metabolic pathway. The gluconeogenic module operates through assisted loading, whereby GR doubles the number of sites occupied by CREB1 as well as enhances CREB1 binding intensity and increases accessibility of CREB1 binding sites. Importantly, this GR-assisted CREB1 binding was enhancer-selective and did not affect all CREB1-bound enhancers. Single-molecule tracking revealed that GR increases the number and DNA residence time of a portion of chromatin-bound CREB1 molecules. These events collectively result in rapid synergistic gene expression and higher hepatic glucose production. Conversely, the ketogenic module operates via a GR-induced TF cascade, whereby PPARA levels are increased following GR activation, facilitating gradual enhancer maturation next to PPARA target genes and delayed ketogenic gene expression. Our findings reveal a complex network of enhancers and TFs that dynamically cooperate to restore homeostasis upon fasting. PMID:28031249

  6. Application of Fracture Mechanics to Specify the Proof Load Factor for Clamp Band Systems of Launch Vehicles

    Science.gov (United States)

    Singaravelu, J.; Sundaresan, S.; Nageswara Rao, B.

    2013-04-01

    This article presents a methodology for evaluation of the proof load factor (PLF) for clamp band system (CBS) made of M250 Maraging steel following fracture mechanics principles.CBS is most widely used as a structural element and as a separation system. Using Taguchi's design of experiments and the response surface method (RSM) the compact tension specimens were tested to establish an empirical relation for the failure load ( P max) in terms of the ultimate strength, width, thickness, and initial crack length. The test results of P max closely matched with the developed RSM empirical relation. Crack growth rates of the maraging steel in different environments were examined. Fracture strength (σf) of center surface cracks and through-crack tension specimens are evaluated utilizing the fracture toughness ( K IC). Stress induced in merman band at flight loading conditions is evaluated to estimate the higher load factor and PLF. Statistical safety factor and reliability assessments were made for the specified flaw sizes useful in the development of fracture control plan for CBS of launch vehicles.

  7. Determination of the usage factor of components after cyclic loading by means of high-resolution microstructural examination

    International Nuclear Information System (INIS)

    Seibold, A.; Scheibe, A.; Assmann, H.D.

    1991-01-01

    Materials subjected to cyclic loading experience a change in the microstructure which may affect the service life. Quantification of the microstructural changes and allocation of the microstructural condition to the corresponding point on the fatigue curve for the component material allows the usage factor to be derived. Taking the low-alloy, fine-grained structural steel 20MnMoNi55 (quenched and tempered structure) as an example, the relationship between microstructure and number of load cycles can be represented in the form of a reference curve. High-resolution examination allows the usage factor to be determined up to η=N/N f ≅0.5 under the given cyclic loading. Only a small specimen volume is required for examination using a transmission electron microscope. It can be taken from the component without affecting the required minimum wall thickness. The location of the specimen must, however, be stipulated, e.g. the location of highest loading according to calculations. When removing the specimen, care must be taken to ensure that the micro-structure is not affected. If these requirements are observed, high-resolution microstructural examination provides a method for checking the usage factor of a component. (orig.)

  8. Embedded data collector (EDC) phase II load and resistance factor design (LRFD) : [summary].

    Science.gov (United States)

    2015-07-01

    Piles that support bridge structures are designed for the specific site characteristics and loads : that the piles are expected to bear. In Florida, driven piles are monitored during installation : (dynamically tested) to assess resistance, com...

  9. Influence of load type on power factor and harmonic composition of three-phase rectifier current

    Science.gov (United States)

    Nikolayzin, N. V.; Vstavskaya, E. V.; Konstantinov, V. I.; Konstantinova, O. V.

    2018-05-01

    This article is devoted to research of the harmonic composition of the three-phase rectifier current consumed when it operates with different types of load. The results are compared with Standard requirements.

  10. Risk factors and long-term outcomes of pediatric liver transplant recipients with chronic high Epstein-Barr virus loads.

    Science.gov (United States)

    Kamei, Hideya; Ito, Yoshinori; Kawada, Junichi; Ogiso, Satoshi; Onishi, Yasuharu; Komagome, Masahiko; Kurata, Nobuhiko; Ogura, Yasuhiro

    2018-04-20

    Serial monitoring of Epstein-Barr virus (EBV) reveals that certain pediatric liver transplant (LT) recipients exhibit high EBV loads for long periods. We investigated the incidence and risk factors of chronic high EBV (CHEBV) loads (continuous EBV DNA >10 000 IU/mL of whole blood for ≥6 months) and long-term outcomes. This single center, retrospective observational study investigated pediatric LT recipients who survived ≥6 months. We quantitated EBV DNA weekly during hospitalization and subsequently every 4 or 6 weeks at the outpatient clinic. Tacrolimus was maintained at a low trough level (5000 IU/mL). Thirty-one of 77 LT recipients developed CHEBV. Univariate analysis revealed that age 35 minutes, graft-to-recipient weight ratio (GRWR) >2.7%, and preoperative EBV seronegativity were significantly associated with the development of CHEBV loads. Multivariate analysis identified significant associations of CHEBV with WIT >35 minutes, GRWR >2.7%, and preoperative seronegative. None of the recipients developed post-transplantation lymphoproliferative disorder. Survival rates of patients with and without CHEBV loads were not significantly different. A significant number of pediatric LT recipients developed CHEBV loads. Long WIT, high GRWR, and preoperative EBV seronegativity were significantly associated with the development of CHEBV loads. Although the long-term outcomes of patients with or without CHEBV loads were not significantly different, further studies of more subjects are warranted. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Evaluation of the Effect of Platelet-Released Growth Factor and Immediate Orthodontic Loading on the Removal Torque of Miniscrews.

    Science.gov (United States)

    Bayani, Shahin; Masoomi, Fatemeh; Aghaabbasi, Sharereh; Farsinejad, Alireza

    2016-01-01

    The purpose of this study was to evaluate the effect of platelet-released growth factor (PRGF) and immediate orthodontic forces on the removal torque of miniscrews. This study was conducted on three male dogs aged 6 to 8 months with a body weight of 17.6 to 18.4 kg. Sixty miniscrews were inserted in the posterior aspect of the femur. There were four groups, including loaded miniscrews with application of PRGF, unloaded miniscrews without application of PRGF, unloaded miniscrews with PRGF, and loaded miniscrews without PRGF. Twenty miniscrews were inserted in the femoral bone of one foot of each dog, including all the aforementioned subgroups. After 12 weeks, the miniscrews were removed by a removal torque tester device and measured in newton centimeters. The mean removal torque values in four groups of immediately loaded screws with PRGF, unloaded screws with PRGF, immediately loaded screws without PRGF, and unloaded screws without PRGF were 19.68, 21.74, 13.65, and 15.46 Ncm, respectively. It was shown that the mean removal torque value for the group with PRGF was significantly higher than that in the other groups (P = .0001). Although there was a tendency toward a decrease in removal torque value with immediate loading, it was not statistically significant (P = .21). According to the results of this study, applying PRGF with miniscrews increased their stability, but the delivery of immediate force on miniscrews had no effect on the miniscrews' stability.

  12. Night shift work at specific age ranges and chronic disease risk factors

    Science.gov (United States)

    Ramin, Cody; Devore, Elizabeth E; Wang, Weike; Pierre-Paul, Jeffrey; Wegrzyn, Lani R; Schernhammer, Eva S

    2014-01-01

    Objectives We examined the association of night shift work history and age when night shift work was performed with cancer and cardiovascular disease risk factors among 54 724 women in the Nurses' Health Study (NHS) II. Methods We calculated age-adjusted and socioeconomic status-adjusted means and percentages for cancer and cardiovascular risk factors in 2009 across categories of night shift work history. We used multivariable-adjusted logistic regression to estimate odds ratios (ORs) and 95% CIs for key risk factors among 54 724 participants (72% ever shift workers). We further examined these associations by age (20–25, 26–35, 36– 45 and 46+ years) at which shift work was performed. Results Ever night shift workers had increased odds of obesity (body mass index ≥30 kg/m2; OR=1.37, 95% CI 1.31 to 1.43); higher caffeine intake (≥131 mg/day; OR=1.16, 95% CI 1.12 to 1.22) and total calorie intake (≥1715 kcal/day; OR=1.09, 95% CI 1.04 to 1.13); current smoking (OR=1.30, 95% CI 1.19 to 1.42); and shorter sleep durations (≤7 h of sleep/day; OR=1.19, 95% CI 1.15 to 1.24) compared to never night shift workers. These estimates varied depending on age at which night work was performed, with a suggestion that night shift work before age 25 was associated with fewer risk factors compared to night shift work at older ages. Conclusions Our results indicate that night shift work may contribute to an adverse chronic disease risk profile, and that risk factors may vary depending on the age at which night shift work was performed. PMID:25261528

  13. Unresolved resonance range cross section, probability tables and self shielding factor

    International Nuclear Information System (INIS)

    Sublet, J.Ch.; Blomquist, R.N.; Goluoglu, S.; Mac Farlane, R.E.

    2009-07-01

    The performance and methodology of 4 processing codes have been compared in the unresolved resonance range of a selected set of isotopes. Those isotopes have been chosen to encompass most cases encountered in the unresolved energy range contained in major libraries like Endf/B-7 or Jeff-3.1.1. The code results comparison is accompanied by data format and formalism examinations and processing code fine-interpretation study. After some improvements, the results showed generally good agreement, although not perfect with infinite dilute cross-sections. However, much larger differences occur when shelf-shielded effective cross-sections are compared. The infinitely dilute cross-section are often plot checked but it is the probability table derived and shelf-shielded cross sections that are used and interpreted in criticality and transport calculations. This suggests that the current evaluation data format and formalism, in the unresolved resonance range should be tightened up, ambiguities removed. In addition production of the shelf shielded cross-sections should be converged to a much greater accuracy. (author)

  14. Hierarchy of factors exerting an impact on nutrient load of the Baltic Sea and sustainable management of its drainage basin.

    Science.gov (United States)

    Kiedrzyńska, Edyta; Jóźwik, Adam; Kiedrzyński, Marcin; Zalewski, Maciej

    2014-11-15

    The aim of the paper was to evaluate 23 catchment factors that determine total phosphorus and total nitrogen load to the Baltic Sea. Standard correlation analysis and clustering were used. Both phosphorus and nitrogen loads were found to be positively related to the number of pigs and the human population associated with wastewater treatment plants (WWTPs) per km(2), while the number of cattle and agricultural area were found to influence nitrogen rather than phosphorus load, and the area of forests is negatively related to loads of both nutrients. Clustering indicates an overall north-south pattern in the spatial co-occurrence of socio-ecological factors, with some exceptions discussed in the paper. Positive steps in the Baltic Sea region have already been taken, but much remains to be done. The development of coherent response policies to reduce eutrophication in the Baltic Sea should be based on a comprehensive knowledge base, an appropriate information strategy and learning alliance platform in each drainage river catchments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Enhancement of skin wound healing with decellularized scaffolds loaded with hyaluronic acid and epidermal growth factor

    Energy Technology Data Exchange (ETDEWEB)

    Su, Zhongchun; Ma, Huan; Wu, Zhengzheng [Institute of Biomedicine, National Engineering Research Center of Genetic Medicine, Key Lab for Genetic Medicine of Guangdong Province, Jinan University, Guangzhou 510632 (China); Zeng, Huilan [Department of Hematology, The First Affiliated Hospital, Jinan University, Guangzhou 510632 (China); Li, Zhizhong [Department of Bone, The First Affiliated Hospital, Jinan University, Guangzhou 510632 (China); Wang, Yuechun; Liu, Gexiu [Department of Physiology, School of Medicine, Jinan University, Guangzhou 510632 (China); Xu, Bin; Lin, Yongliang; Zhang, Peng [Grandhope Biotech Co., Ltd., Building D, #408, Guangzhou International Business Incubator, Guangzhou Science Park, Guangzhou 510663, Guangdong (China); Wei, Xing, E-mail: wei70@hotmail.com [Institute of Biomedicine, National Engineering Research Center of Genetic Medicine, Key Lab for Genetic Medicine of Guangdong Province, Jinan University, Guangzhou 510632 (China)

    2014-11-01

    Current therapy for skin wound healing still relies on skin transplantation. Many studies were done to try to find out ways to replace skin transplantation, but there is still no effective alternative therapy. In this study, decellularized scaffolds were prepared from pig peritoneum by a series of physical and chemical treatments, and scaffolds loaded with hyaluronic acid (HA) and epidermal growth factor (EGF) were tested for their effect on wound healing. MTT assay showed that EGF increased NIH3T3 cell viability and confirmed that EGF used in this study was biologically active in vitro. Scanning electron microscope (SEM) showed that HA stably attached to scaffolds even after soaking in PBS for 48 h. ELISA assay showed that HA increased the adsorption of EGF to scaffolds and sustained the release of EGF from scaffolds. Animal study showed that the wounds covered with scaffolds containing HA and EGF recovered best among all 4 groups and had wound healing rates of 49.86%, 70.94% and 87.41% respectively for days 10, 15 and 20 post-surgery compared to scaffolds alone with wound healing rates of 29.26%, 42.80% and 70.14%. In addition, the wounds covered with scaffolds containing EGF alone were smaller than no EGF scaffolds on days 10, 15 and 20 post-surgery. Hematoxylin–Eosin (HE) staining confirmed these results by showing that on days 10, 15 and 20 post-surgery, the thicker epidermis and dermis layers were observed in the wounds covered with scaffolds containing HA and EGF than scaffolds alone. In addition, the thicker epidermis and dermis layers were also observed in the wounds covered with scaffolds containing EGF than scaffolds alone. Skin appendages were observed on day 20 only in the wound covered with scaffolds containing HA and EGF. These results demonstrate that the scaffolds containing HA and EGF can enhance wound healing. - Highlights: • HA can increase the adsorption of EGF to decellularized scaffolds. • HA can sustain the release of EGF from

  16. Structural basis for antagonizing a host restriction factor by C7 family of poxvirus host-range proteins

    OpenAIRE

    Meng, Xiangzhi; Krumm, Brian; Li, Yongchao; Deng, Junpeng; Xiang, Yan

    2015-01-01

    Productive viral replication requires overcoming many barriers posed by the host innate immune system. Human sterile alpha motif domain-containing 9 (SAMD9) is a newly identified antiviral factor that is specifically targeted by poxvirus proteins belonging to the C7 family of host-range factors. Here we provide the first, to our knowledge, atomic view of two functionally divergent proteins from the C7 family and determine the molecular basis that dictates whether they can target SAMD9 effecti...

  17. Seroprevalence and risk factors of Chlamydia abortus infection in free-ranging white yaks in China

    OpenAIRE

    Qin, Si-Yuan; Huang, Si-Yang; Yin, Ming-Yang; Tan, Qi-Dong; Liu, Guang-Xue; Zhou, Dong-Hui; Zhu, Xing-Quan; Zhou, Ji-Zhang; Qian, Ai-Dong

    2015-01-01

    Background Chlamydia is gram-negative obligate bacteria which causes a wide variety of diseases in humans and animals. To date, there are a few reports about the seroprevalence of Chlamydia and the risk factors associated with Chlamydia infection in yaks in the world. In this study, 974 blood samples were collected from white yaks (Bos grunniens) in Tianzhu Tibetan Autonomous County, Gansu province, northwest China from June 2013 to April 2014. Results Antibodies against Chlamydia abortus wer...

  18. Night shift work at specific age ranges and chronic disease risk factors.

    Science.gov (United States)

    Ramin, Cody; Devore, Elizabeth E; Wang, Weike; Pierre-Paul, Jeffrey; Wegrzyn, Lani R; Schernhammer, Eva S

    2015-02-01

    We examined the association of night shift work history and age when night shift work was performed with cancer and cardiovascular disease risk factors among 54 724 women in the Nurses' Health Study (NHS) II. We calculated age-adjusted and socioeconomic status-adjusted means and percentages for cancer and cardiovascular risk factors in 2009 across categories of night shift work history. We used multivariable-adjusted logistic regression to estimate odds ratios (ORs) and 95% CIs for key risk factors among 54 724 participants (72% ever shift workers). We further examined these associations by age (20-25, 26-35, 36-45 and 46+ years) at which shift work was performed. Ever night shift workers had increased odds of obesity (body mass index ≥30 kg/m(2); OR=1.37, 95% CI 1.31 to 1.43); higher caffeine intake (≥131 mg/day; OR=1.16, 95% CI 1.12 to 1.22) and total calorie intake (≥1715 kcal/day; OR=1.09, 95% CI 1.04 to 1.13); current smoking (OR=1.30, 95% CI 1.19 to 1.42); and shorter sleep durations (≤7 h of sleep/day; OR=1.19, 95% CI 1.15 to 1.24) compared to never night shift workers. These estimates varied depending on age at which night work was performed, with a suggestion that night shift work before age 25 was associated with fewer risk factors compared to night shift work at older ages. Our results indicate that night shift work may contribute to an adverse chronic disease risk profile, and that risk factors may vary depending on the age at which night shift work was performed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  20. Expression of insulin-like growth factor I, insulin-like growth factor binding proteins, and collagen mRNA in mechanically loaded plantaris tendon

    DEFF Research Database (Denmark)

    Olesen, Jens L; Heinemeier, Katja M; Haddad, Fadia

    2006-01-01

    Insulin-like growth factor I (IGF-I) is known to exert an anabolic effect on tendon fibroblast production of collagen. IGF-I's regulation is complex and involves six different IGF binding proteins (IGFBPs). Of these, IGFBP-4 and -5 could potentially influence the effect of IGF-I in the tendon...... because they both are produced in fibroblast; however, the response of IGFBP-4 and -5 to mechanical loading and their role in IGF-I regulation in tendinous tissue are unknown. A splice variant of IGF-I, mechano-growth factor (MGF) is upregulated and known to be important for adaptation in loaded muscle....... However, it is not known whether MGF is expressed and upregulated in mechanically loaded tendon. This study examined the effect of mechanical load on tendon collagen mRNA in relation to changes in the IGF-I systems mRNA expression. Data were collected at 2, 4, 8 and 16 days after surgical removal...

  1. Influence of a range of extreme environmental factors on tripartite lichen Peltigera aphthosa thallus viability

    Science.gov (United States)

    Irina, Insarova; Dyakov, Max; Ptushenko, Vasiliy; Shtaer, Oksana

    Lichens are symbiotic organisms consisting of at least two genetic different partners: a heterotrophic fungus (mycobiont) and a phototrophic alga or cyanobacterium (photobiont). Lichens are ubiquitous at global scale. These symbiotic organisms represent the dominant type of “vegetation” at 8 - 10% of land (Larson, 1987). Abiotic stress’ resistance is notable for lichens among all eukaryotes. Lichens are often called “extremophiles” for their ability to acclimate the most severe environmental conditions. These features allow regarding lichens as a group of organisms which is potentially able to keep viability under open space conditions and to survive within Mars-like atmosphere types. The research presented was carried out in the network of spacecraft Bion-1 experiments involving the investigation of physiological and ultrastructural changes in biological objects survivable under open space conditions. Similar researches were already conducted on bipartite lichen species. The most attention was paid to the influence of UV and other space radiation types on lichen viability in those works. Thus we have taken tripartite lichen Peltigera aphthosa as a main research object and temperature fluctuations from extremely high to extremely low values in accordance to solar and umbral orbit sides - for the main extreme environmental factors. These factors were the less studied in previous works. During the research the influence of incubation under anaerobic conditions, multi-time effects of high and low temperatures and their interchange on respiratory metabolism, photosynthetic apparatus condition and the ultrastructure of P. aphthosa thalli was assessed. The data obtained demonstrate that activity either mycobiont or photobiont in tripartite lichen Peltigera aphthosa keep near unchanged under influence of all stress factors explored on dry thalli.

  2. Edge loading in metal-on-metal hips: low clearance is a new risk factor.

    Science.gov (United States)

    Underwood, Richard J; Zografos, Angelos; Sayles, Ritchie S; Hart, Alister; Cann, Philippa

    2012-03-01

    The revision rate of large head metal-on-metal and resurfacing hips are significantly higher than conventional total hip replacements. The revision of these components has been linked to high wear caused by edge loading; which occurs when the head-cup contact patch extends over the cup rim. There are two current explanations for this; first, there is loss of entrainment of synovial fluid resulting in breakdown of the lubricating film and second, edge loading results in a large local increase in contact pressure and consequent film thickness reduction at the cup rim, which causes an increase in wear. This paper develops a method to calculate the distance between the joint reaction force vector and the cup rim--the contact patch centre to rim (CPCR) distance. However, the critical distance for the risk of edge loading is the distance from the contact patch edge to rim (CPER) distance. An analysis of explanted hip components, divided into edge worn and non-edge-worn components showed that there was no statistical difference in CPCR values, but the CPER value was significantly lower for edge worn hips. Low clearance hips, which have a more conformal contact, have a larger diameter contact patch and thus are more at risk of edge loading for similarly positioned hips.

  3. Instructional Benefits of Spoken Words: A Review of Cognitive Load Factors

    Science.gov (United States)

    Kalyuga, Slava

    2012-01-01

    Spoken words have always been an important component of traditional instruction. With the development of modern educational technology tools, spoken text more often replaces or supplements written or on-screen textual representations. However, there could be a cognitive load cost involved in this trend, as spoken words can have both benefits and…

  4. Factors affecting velvet antler weights in free-ranging reindeer in Alaska

    Directory of Open Access Journals (Sweden)

    Alexander K. Prichard

    1999-04-01

    Full Text Available Free-ranging reindeer on the Seward Peninsula in western Alaska are rounded up from late May to early July and antlers are removed. We used data collected from 1987 to 1997 to determine how velvet antler weights of males and females varied with age, year, reproductive status, Julian date, and body weight. Male antler weights increased with age up to age five years, and were lower in castrates than in bulls. There was a significant positive relationship between body weight and antler weight in both sexes. Female antler weights increased with age until at least age nine. Lactating females had lower antler weights than non-lactating females, but this effect is better explained by differences in body weight. Antler weight of individual reindeer at age two years was better predicted by their antler weights as yearlings than their body weight as yearlings.

  5. Extrinsic factors significantly affect patterns of disease in free-ranging and captive cheetah (Acinonyx jubatus) populations.

    Science.gov (United States)

    Munson, Linda; Terio, Karen A; Worley, Michael; Jago, Mark; Bagot-Smith, Arthur; Marker, Laurie

    2005-07-01

    The cheetah (Acinonyx jubatus) has been considered a paradigm for disease vulnerability due to loss of genetic diversity. This species monomorphism has been suspected to be the basis for their general poor health and dwindling populations in captivity. North American and South African captive populations have high prevalences of hepatic veno-occlusive disease, glomerulosclerosis, gastritis, and systemic amyloidosis, diseases that are rare in other species. Unusually severe inflammatory reactions to common infectious agents have also been documented in captive cheetahs. The current study compared disease prevalences in free-ranging Namibian cheetahs with those in two captive populations of similar ages. The occurrence of diseases in the free-ranging population was determined from 49 necropsies and 27 gastric biopsies obtained between 1986 and 2003 and compared with prevalences in 147 North American and 80 South African captive cheetahs. Except for two cheetahs, the free-ranging population was in robust health with only mild lesions present, in contrast with significantly higher prevalences in the captive populations. Despite widespread heavy Helicobacter colonization in wild cheetahs, only 3% of the free-ranging population had moderate to severe gastritis, in contrast with 64% of captive cheetahs. No severe inflammatory reactions to viral infections were detected in the free-ranging animals. Because free-ranging Namibian cheetahs are as genetically impoverished as captive cheetahs, these findings caution against attributing loss of fitness solely to genetic factors and attest to the fundamental importance of extrinsic factors in wildlife health.

  6. Mortality factors and diseases in free-ranging Eurasian cranes (Grus grus) in Germany.

    Science.gov (United States)

    Fanke, Jane; Wibbelt, Gudrun; Krone, Oliver

    2011-07-01

    Detailed postmortem examinations were performed on 167 free-ranging Eurasian Cranes (Grus grus) from Germany, collected between September 1998 and December 2008 to evaluate causes of death and diseases. The most common causes of mortality were traumatic injuries (n=105, 62.9%) from collisions with power lines (n=39, 23.4%) and wire fences (n=12, 7.2%). A group of 28 Eurasian Cranes (16.8%) died from organophosphate intoxication. Predation by White-tailed Sea Eagles (Haliaeetus albicilla) and red foxes (Vulpes vulpes) occurred in four cases (2.4%). Pathologic changes due to infectious diseases were associated with Aspergillus spp. (n=7, 4.2%), endoparasites (n=7, 4.2%), avian poxvirus (n=6, 3.6%), Mycobacterium spp. (n=2, 1.2%), and adenovirus infection (n=1, 0.6%). A severe Strigea spp. infection (n=1, 0.6%) and a leiomyosarcoma (n=1, 0.6%) were newly recognized diseases in Eurasian Cranes in this study.

  7. Performance study of K{sub e} factors in simplified elastic plastic fatigue analyses with emphasis on thermal cyclic loading

    Energy Technology Data Exchange (ETDEWEB)

    Lang, Hermann, E-mail: hermann.lang@areva.com [AREVA NP GmbH, PEEA-G, Henri-Dunant-Strasse 50, 91058 Erlangen (Germany); Rudolph, Juergen; Ziegler, Rainer [AREVA NP GmbH, PEEA-G, Henri-Dunant-Strasse 50, 91058 Erlangen (Germany)

    2011-08-15

    As code-based fully elastic plastic code conforming fatigue analyses are still time consuming, simplified elastic plastic analysis is often applied. This procedure is known to be overly conservative for some conditions due to the applied plastification (penalty) factor K{sub e}. As a consequence, less conservative fully elastic plastic fatigue analyses based on non-linear finite element analyses (FEA) or simplified elastic plastic analysis based on more realistic K{sub e} factors have to be used for fatigue design. The demand for more realistic K{sub e} factors is covered as a requirement of practical fatigue analysis. Different code-based K{sub e} procedures are reviewed in this paper with special regard to performance under thermal cyclic loading conditions. Other approximation formulae such as those by Neuber, Seeger/Beste or Kuehnapfel are not evaluated in this context because of their applicability to mechanical loading excluding thermal cyclic loading conditions typical for power plant operation. Besides the current code-based K{sub e} corrections, the ASME Code Case N-779 (e.g. Adam's proposal) and its modification in ASME Section VIII is considered. Comparison of elastic plastic results and results from the Rules for Nuclear Facility Components and Rules for Pressure Vessels reveals a considerable overestimation of usage factor in the case of ASME III and KTA 3201.2 for the examined examples. Usage factors according to RCC-M, Adams (ASME Code Case N-779), ASME VIII (alternative) and EN 13445-3 are essentially comparable and less conservative for these examples. The K{sub v} correction as well as the applied yield criterion (Tresca or von Mises) essentially influence the quality of the more advanced plasticity corrections (e.g. ASME Code Case N-779 and RCC-M). Hence, new proposals are based on a refined K{sub v} correction.

  8. Performance study of Ke factors in simplified elastic plastic fatigue analyses with emphasis on thermal cyclic loading

    International Nuclear Information System (INIS)

    Lang, Hermann; Rudolph, Juergen; Ziegler, Rainer

    2011-01-01

    As code-based fully elastic plastic code conforming fatigue analyses are still time consuming, simplified elastic plastic analysis is often applied. This procedure is known to be overly conservative for some conditions due to the applied plastification (penalty) factor K e . As a consequence, less conservative fully elastic plastic fatigue analyses based on non-linear finite element analyses (FEA) or simplified elastic plastic analysis based on more realistic K e factors have to be used for fatigue design. The demand for more realistic K e factors is covered as a requirement of practical fatigue analysis. Different code-based K e procedures are reviewed in this paper with special regard to performance under thermal cyclic loading conditions. Other approximation formulae such as those by Neuber, Seeger/Beste or Kuehnapfel are not evaluated in this context because of their applicability to mechanical loading excluding thermal cyclic loading conditions typical for power plant operation. Besides the current code-based K e corrections, the ASME Code Case N-779 (e.g. Adam's proposal) and its modification in ASME Section VIII is considered. Comparison of elastic plastic results and results from the Rules for Nuclear Facility Components and Rules for Pressure Vessels reveals a considerable overestimation of usage factor in the case of ASME III and KTA 3201.2 for the examined examples. Usage factors according to RCC-M, Adams (ASME Code Case N-779), ASME VIII (alternative) and EN 13445-3 are essentially comparable and less conservative for these examples. The K v correction as well as the applied yield criterion (Tresca or von Mises) essentially influence the quality of the more advanced plasticity corrections (e.g. ASME Code Case N-779 and RCC-M). Hence, new proposals are based on a refined K v correction.

  9. Effect of Loads and Other Key Factors on Oil-Transformer Ageing: Sustainability Benefits and Challenges

    OpenAIRE

    Radu Godina; Eduardo M. G. Rodrigues; João C. O. Matias; João P. S. Catalão

    2015-01-01

    Transformers are one of the more expensive pieces of equipment found in a distribution network. The transformer’s role has not changed over the last decades. With simple construction and at the same time mechanically robust, they offer long term service that on average can reach half a century. Today, with the ongoing trend to supply a growing number of non-linear loads along with the notion of distributed generation (DG), a new challenge has arisen in terms of transformer sustainability, ...

  10. Stress Intensity Factors for Cracked Metallic Structures Under Rapid Thermal Loading

    Science.gov (United States)

    1987-10-01

    solution algorithm was developed based on the influence function method, and numerical results were generated to show the variation of K with flaw size and...numerical algorithms developed can be executed on a desktop microcomputer illustrating the efficient and powerful characteristic of the influence function method... Function Method 3-6 Superposition and Crack Face Loading Equivalence 3-7 Influence Function Generation 3-10 Influence Functions For Two Cracked Body

  11. Comparison of Antibiotic Resistance and Virulence Factors among Escherichia coli Isolated from Conventional and Free-Range Poultry

    Directory of Open Access Journals (Sweden)

    Vanessa L. Koga

    2015-01-01

    Full Text Available Microbiological contamination in commercial poultry production has caused concerns for human health because of both the presence of pathogenic microorganisms and the increase in antimicrobial resistance in bacterial strains that can cause treatment failure of human infections. The aim of our study was to analyze the profile of antimicrobial resistance and virulence factors of E. coli isolates from chicken carcasses obtained from different farming systems (conventional and free-range poultry. A total of 156 E. coli strains were isolated and characterized for genes encoding virulence factors described in extraintestinal pathogenic E. coli (ExPEC. Antimicrobial susceptibility testing was performed for 15 antimicrobials, and strains were confirmed as extended spectrum of β-lactamases- (ESBLs- producing E. coli by phenotypic and genotypic tests. The results indicated that strains from free-range poultry have fewer virulence factors than strains from conventional poultry. Strains from conventionally raised chickens had a higher frequency of antimicrobial resistance for all antibiotics tested and also exhibited genes encoding ESBL and AmpC, unlike free-range poultry isolates, which did not. Group 2 CTX-M and CIT were the most prevalent ESBL and AmpC genes, respectively. The farming systems of poultries can be related with the frequency of virulence factors and resistance to antimicrobials in bacteria.

  12. Factors affecting fecal glucocorticoid levels in semi-free-ranging female mandrills (Mandrillus sphinx).

    Science.gov (United States)

    Setchell, Joanna M; Smith, Tessa; Wickings, E Jean; Knapp, Leslie A

    2008-11-01

    Subordinate female cercopithecine primates often experience decreased reproductive success in comparison with high-ranking females, with a later age at sexual maturity and first reproduction and/or longer interbirth intervals. One explanation that has traditionally been advanced to explain this is high levels of chronic social stress in subordinates, resulting from agonistic and aggressive interactions and leading to higher basal levels of glucocorticoids. We assessed the relationships among fecal cortisol levels and reproductive condition, dominance rank, degree of social support, and fertility in female mandrills (Mandrillus sphinx) living in a semi-free-ranging colony in Franceville, Gabon. Lower-ranking females in this colony have a reproductive disadvantage relative to higher-ranking females, and we were interested in determining whether this relationship between dominance rank and reproductive success is mediated through stress hormones. We analyzed 340 fecal samples from 19 females, collected over a 14-month period. We found that pregnant females experienced higher fecal cortisol levels than cycling or lactating females. This is similar to results for other primate species and is likely owing to increased metabolic demands and interactions between the hypothalamus-pituitary-adrenal axis, estrogen, and placental production of corticotrophin releasing hormones during pregnancy. There was no influence of dominance rank on fecal cortisol levels, suggesting that subordinate females do not suffer chronic stress. This may be because female mandrills have a stable social hierarchy, with low levels of aggression and high social support. However, we found no relationship between matriline size, as a measure of social support, and fecal cortisol levels. Subordinates may be able to avoid aggression from dominants in the large enclosure or may react only transiently to specific aggressive events, rather than continuously expecting them. Finally, we found no relationship

  13. Ballast Load Control of Turbine-Generator Sets in the Micro-Hydro Range with a Turbine that has no Flow Regulating Value

    Directory of Open Access Journals (Sweden)

    Valentin Nedelea

    2011-09-01

    Full Text Available This paper presents the effects of voltage and frequency variation on users load supplies from electrical supply system generated from small micro-hydro plants. Induction generators operate as stand-alone self excited by capacitors and turbine has no flow regulating valve. Many conventional and non conventional approaches are described to govern turbine-generator set to ensure a steady frequency and voltage level. A load controller increases or decreases a ballast load connected across the generator as the user load varies, to keep frequency and voltage variation in standard limits. To design a controller for self excited induction generator, researches were performed on asynchronous generator with double winding stator to analyse steady state open loop behaviour. The results on the behaviour of the unregulated turbine (DC motor – generator system was presented.

  14. Factors controlling stream water nitrate and phosphor loads during precipitation events

    Science.gov (United States)

    Rozemeijer, J.; van der Velde, Y.; van Geer, F.; de Rooij, G. H.; Broers, H.; Bierkens, M. F.

    2009-12-01

    Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Within regional surface water quality monitoring networks, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because this natural variability in surface water quality is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous records of stream water N and P concentrations to easier and cheaper to collect quantitative data on precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment we collected continuous measurements of precipitation, groundwater levels and tube drain discharges. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and

  15. Flexibility factors for small (d/D<1/3) branch connections with external loadings

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1977-03-01

    A piping system analysis is accurate only to the extent that the flexibilities of all portions of the piping system are accurately known. The use of a ''conservative'' flexibility factor is not possible because such a factor cannot be defined. Branch connections require a definition of flexibility factor which is conceptually different than commonly used for curved pipe. An appropriate definition for the flexibility factors of branch connections is presented. The background of the present Code formulations of flexibility factors for branch connections is discussed. Additional theoretical data and test data are summarized. Recommendations are given for revisions to Code formulations for handling the flexibility of branch connections in a piping system analysis

  16. Refined shear correction factor for very thick simply supported and uniformly loaded isosceles right triangular auxetic plates

    International Nuclear Information System (INIS)

    Lim, Teik-Cheng

    2016-01-01

    For moderately thick plates, the use of First order Shear Deformation Theory (FSDT) with a constant shear correction factor of 5/6 is sufficient to take into account the plate deflection arising from transverse shear deformation. For very thick plates, the use of Third order Shear Deformation Theory (TSDT) is preferred as it allows the shear strain distribution to be varied through the plate thickness. Therefore no correction factor is required in TSDT, unlike FSDT. Due to the complexity involved in TSDT, this paper obtains a more accurate shear correction factor for use in FSDT of very thick simply supported and uniformly loaded isosceles right triangular plates based on the TSDT. By matching the maximum deflections for this plate according to FSDT and TSDT, a variable shear correction factor is obtained. Results show that the shear correction factor for the simplified TSDT, i.e. 14/17, is least accurate. The commonly adopted shear correction factor of 5/6 in FSDT is valid only for very thin or highly auxetic plates. This paper provides a variable shear correction for FSDT deflection that matches the plate deflection by TSDT. This variable shear correction factor allows designers to justify the use of a commonly adopted shear correction factor of 5/6 even for very thick plates as long as the Poisson’s ratio of the plate material is sufficiently negative. (paper)

  17. Family load estimates and risk factors of anxiety disorders in a nationwide three generation study

    DEFF Research Database (Denmark)

    Helenius, Dorte; Munk-Jørgensen, Povl; Steinhausen, Hans-Christoph

    2014-01-01

    region. Psychiatric diagnoses were also obtained for parents, siblings, and offspring. A family load component was obtained by using various mixed regression models. Anxiety disorders occurred significantly more often in case than in control families. Having a mother, father, or a sibling......The present study investigated how often anxiety disorders with different ages of onset occurred in affected families compared to control families. Furthermore, the study addressed the impact of sex, region of residence, year and month of birth, and parental age at birth. The sample included N=1373......, provide further and solid evidence for the family aggregation of anxiety disorders....

  18. Design of a 4 1/2 stage turbine with a stage loading factor of 4.66 and high specific work output

    Science.gov (United States)

    Webster, P. F.

    1976-01-01

    The aerodynamic design of a highly loaded multistage fan drive turbine is discussed. Turbine flowpath and airfoil sections are presented along with respective pressure and velocity distributions. Vibrational modes are identified in the expected turbine operating range.

  19. Dextran-based hydrogel containing chitosan microparticles loaded with growth factors to be used in wound healing

    International Nuclear Information System (INIS)

    Ribeiro, M.P.; Morgado, P.I.; Miguel, S.P.; Coutinho, P.; Correia, I.J.

    2013-01-01

    Skin injuries are traumatic events, which are seldom accompanied by complete structural and functional restoration of the original tissue. Different strategies have been developed in order to make the wound healing process faster and less painful. In the present study in vitro and in vivo assays were carried out to evaluate the applicability of a dextran hydrogel loaded with chitosan microparticles containing epidermal and vascular endothelial growth factors, for the improvement of the wound healing process. The carriers' morphology was characterized by scanning electron microscopy. Their cytotoxicity profile and degradation by-products were evaluated through in vitro assays. In vivo experiments were also performed to evaluate their applicability for the treatment of skin burns. The wound healing process was monitored through macroscopic and histological analysis. The macroscopic analysis showed that the period for wound healing occurs in animals treated with microparticle loaded hydrogels containing growth factors that were considerably smaller than that of control groups. Moreover, the histological analysis revealed the absence of reactive or granulomatous inflammatory reaction in skin lesions. The results obtained both in vitro and in vivo disclosed that these systems and its degradation by-products are biocompatible, contributed to the re-establishment of skin architecture and can be used in a near future for the controlled delivery of other bioactive agents used in regenerative medicine. - Highlights: • Evaluation of a hydrogel loaded with microparticles containing growth factors for wound healing • In vitro and in vivo assays were performed to characterize the properties of the skin substitute. • The monitoring of the wound healing process was done by macroscopic and histological analysis

  20. Dextran-based hydrogel containing chitosan microparticles loaded with growth factors to be used in wound healing

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, M.P. [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal); UDI-IPG, Research Unit for Inland Development, Polytechnic Institute of Guarda, Guarda (Portugal); Morgado, P.I.; Miguel, S.P. [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal); Coutinho, P. [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal); UDI-IPG, Research Unit for Inland Development, Polytechnic Institute of Guarda, Guarda (Portugal); Correia, I.J., E-mail: icorreia@ubi.pt [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal)

    2013-07-01

    Skin injuries are traumatic events, which are seldom accompanied by complete structural and functional restoration of the original tissue. Different strategies have been developed in order to make the wound healing process faster and less painful. In the present study in vitro and in vivo assays were carried out to evaluate the applicability of a dextran hydrogel loaded with chitosan microparticles containing epidermal and vascular endothelial growth factors, for the improvement of the wound healing process. The carriers' morphology was characterized by scanning electron microscopy. Their cytotoxicity profile and degradation by-products were evaluated through in vitro assays. In vivo experiments were also performed to evaluate their applicability for the treatment of skin burns. The wound healing process was monitored through macroscopic and histological analysis. The macroscopic analysis showed that the period for wound healing occurs in animals treated with microparticle loaded hydrogels containing growth factors that were considerably smaller than that of control groups. Moreover, the histological analysis revealed the absence of reactive or granulomatous inflammatory reaction in skin lesions. The results obtained both in vitro and in vivo disclosed that these systems and its degradation by-products are biocompatible, contributed to the re-establishment of skin architecture and can be used in a near future for the controlled delivery of other bioactive agents used in regenerative medicine. - Highlights: • Evaluation of a hydrogel loaded with microparticles containing growth factors for wound healing • In vitro and in vivo assays were performed to characterize the properties of the skin substitute. • The monitoring of the wound healing process was done by macroscopic and histological analysis.

  1. Dependence of twinned volume fraction on loading mode and Schmid factor in randomly textured magnesium

    Czech Academy of Sciences Publication Activity Database

    Čapek, Jan; Máthis, K.; Clausen, B.; Barnett, M.R.

    2017-01-01

    Roč. 130, MAY (2017), s. 319-328 ISSN 1359-6454 R&D Projects: GA ČR GB14-36566G Institutional support: RVO:61389005 Keywords : twinning * magnesium * neutron diffraction * Schmid factor Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 5.301, year: 2016

  2. Monitoring organic loading to swimming pools by fluorescence excitation–emission matrix with parallel factor analysis (PARAFAC)

    DEFF Research Database (Denmark)

    Seredynska-Sobecka, Bozena; Stedmon, Colin; Boe-Hansen, Rasmus

    2011-01-01

    Fluorescence Excitation–Emission Matrix spectroscopy combined with parallel factor analysis was employed to monitor water quality and organic contamination in swimming pools. The fluorescence signal of the swimming pool organic matter was low but increased slightly through the day. The analysis...... revealed that the organic matter fluorescence was characterised by five different components, one of which was unique to swimming pool organic matter and one which was specific to organic contamination. The latter component had emission peaks at 420nm and was found to be a sensitive indicator of organic...... loading in swimming pool water. The fluorescence at 420nm gradually increased during opening hours and represented material accumulating through the day....

  3. Does vertical integration have an effect on load factor? - A test on coal-fired plants in England and Wales

    International Nuclear Information System (INIS)

    Lopez, Jose A.; Salies, Evens

    2006-02-01

    Today in the British electricity industry, most electricity suppliers hedge a large proportion of their residential customer base requirements by owning their own plant. The non-storability of electricity and the corresponding need for an instantaneous matching of generation and consumption creates a business need for integration. From a sample of half-hour data on load factor for coal-fired power plants in England and Wales, this paper tests the hypothesis that vertical integration with retail businesses affects the extent to which producers utilize their capacity. We also pay attention to this potential effect during periods of peak demand. (authors)

  4. Which Factors Can Protect Against Range Stress in Everyday Usage of Battery Electric Vehicles? Toward Enhancing Sustainability of Electric Mobility Systems.

    Science.gov (United States)

    Franke, Thomas; Rauh, Nadine; Günther, Madlen; Trantow, Maria; Krems, Josef F

    2016-02-01

    The objective of the present research was to advance understanding of factors that can protect against range anxiety, specifically range stress in everyday usage of battery electric vehicles (BEVs). Range anxiety is a major barrier to the broad adoption of sustainable electric mobility systems. To develop strategies aimed at overcoming range anxiety, a clear understanding of this phenomenon and influencing factors is needed. We examined range anxiety in the form of everyday range stress (ERS) in a field study setting. Seventy-two customers leased a BEV for 3 months. The field study was specifically designed to enable examination of factors that can contribute to lower ERS. In particular, study design and sample recruitment were targeted at generating vehicle usage profiles that would lead to relatively frequent experience of situations requiring active management of range resources and thereby potentially leading to experienced range stress. Less frequent encounter with critical range situations, higher practical experience, subjective range competence, tolerance of low range, and experienced trustworthiness of the range estimation system were related to lower ERS. Moreover, range stress was found to be related to range satisfaction and BEV acceptance. The results underline the importance of the human factors perspective to overcome range anxiety and enhance sustainability of electric mobility systems. Trustworthiness should be employed as a key benchmark variable in the design of range estimation systems, and assistance systems should target increasing drivers' adaptive capacity (i.e., resilience) to cope with critical range situations. © 2015, Human Factors and Ergonomics Society.

  5. Demand characteristics and load factor in a sugar cane brandy distillery; Caracteristica de demanda e fator de carga numa destilaria de aguardente

    Energy Technology Data Exchange (ETDEWEB)

    Assumpcao, C R [UNESP, Ilha Solteira, SP (Brazil). Faculdade de Engenharia; Souza, L L.G. [UNESP, Botucatu, SP (Brazil). Faculdade de Ciencias Agronomicas

    1987-12-31

    The actual and calculated load factor values were also confronted for both harvests studied, looking for a polynomial equation that could represent the relationships among the variables. (author) 11 refs., 4 figs., 3 tabs.

  6. BEGA Starter/Alternator - Vector Control Implementation and Performance for Wide Speed Range at Unity Power Factor Operation

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Boldea, Ion; Coroban-Schramel, Vasile

    2008-01-01

    Biaxial Excitation Generator for Automobile (BEGA) is proposed as a solution for integrated starter/alternator systems used in hybrid electric vehicles (HEVs). This paper demonstrates through experiments and simulations that BEGA has a very large constant power speed range (CPSR), theoretically...... to infinite. A vector control structure is proposed for BEGA operation during motoring and generating, at unity power factor with zero d-axis current (id) and zero q-axis flux (Ψq) control. In such conditions BEGA behaves like a truly dc. brush machine (with zero reactance in steady state !). A high iq...

  7. BEGA Starter/Alternator—Vector Control Implementation and Performance for Wide Speed Range at Unity Power Factor Operation

    DEFF Research Database (Denmark)

    Boldea, Ion; Coroban-Schramel, Vasile; Andreescu, Gheorghe-Daniel

    2010-01-01

    The Biaxial Excitation Generator for Automobiles (BEGA) is proposed as a solution for integrated starter/alternator systems used in hybrid electric vehicles. This paper demonstrates through experiments and simulations that BEGA has a very large constant power speed range. A vector control structure...... is proposed for BEGA operation during motoring and generating, at unity power factor with zero d-axis current (id) and zero q-axis flux (Ψq) control. In such conditions, BEGA behaves like a separately excited dc brush(commutator) machine, in the sense that no stator inductance voltage drop occurs...

  8. The prediction of the impact of climatic factors on short-term electric power load based on the big data of smart city

    Science.gov (United States)

    Qiu, Yunfei; Li, Xizhong; Zheng, Wei; Hu, Qinghe; Wei, Zhanmeng; Yue, Yaqin

    2017-08-01

    The climate changes have great impact on the residents’ electricity consumption, so the study on the impact of climatic factors on electric power load is of significance. In this paper, the effects of the data of temperature, rainfall and wind of smart city on short-term power load is studied to predict power load. The authors studied the relation between power load and daily temperature, rainfall and wind in the 31 days of January of one year. In the research, the authors used the Matlab neural network toolbox to establish the combinational forecasting model. The authors trained the original input data continuously to get the internal rules inside the data and used the rules to predict the daily power load in the next January. The prediction method relies on the accuracy of weather forecasting. If the weather forecasting is different from the actual weather, we need to correct the climatic factors to ensure accurate prediction.

  9. Critical human-factors issues in nuclear-power regulation and a recommended comprehensive human-factors long-range plan. Critical discussion of human factors areas of concern

    International Nuclear Information System (INIS)

    Hopkins, C.O.; Snyder, H.L.; Price, H.E.; Hornick, R.J.; Mackie, R.R.; Smillie, R.J.; Sugarman, R.C.

    1982-08-01

    This comprehensive long-range human factors plan for nuclear reactor regulation was developed by a Study Group of the Human Factors Society, Inc. This Study Group was selected by the Executive Council of the Society to provide a balanced, experienced human factors perspective to the applications of human factors scientific and engineering knowledge to nuclear power generation. The report is presented in three volumes. Volume 1 contains an Executive Summary of the 18-month effort and its conclusions. Volume 2 summarizes all known nuclear-related human factors activities, evaluates these activities wherever adequate information is available, and describes the recommended long-range (10-year) plan for human factors in regulation. Volume 3 elaborates upon each of the human factors issues and areas of recommended human factors involvement contained in the plan, and discusses the logic that led to the recommendations

  10. Individual co-variation between viral RNA load and gene expression reveals novel host factors during early dengue virus infection of the Aedes aegypti midgut.

    Directory of Open Access Journals (Sweden)

    Vincent Raquin

    2017-12-01

    Full Text Available Dengue virus (DENV causes more human infections than any other mosquito-borne virus. The current lack of antiviral strategies has prompted genome-wide screens for host genes that are required for DENV infectivity. Earlier transcriptomic studies that identified DENV host factors in the primary vector Aedes aegypti used inbred laboratory colonies and/or pools of mosquitoes that erase individual variation. Here, we performed transcriptome sequencing on individual midguts in a field-derived Ae. aegypti population to identify new candidate host factors modulating DENV replication. We analyzed the transcriptomic data using an approach that accounts for individual co-variation between viral RNA load and gene expression. This approach generates a prediction about the agonist or antagonist effect of candidate genes on DENV replication based on the sign of the correlation between gene expression and viral RNA load. Using this method, we identified 39 candidate genes that went undetected by conventional pairwise comparison of gene expression levels between DENV-infected midguts and uninfected controls. Only four candidate genes were detected by both methods, emphasizing their complementarity. We demonstrated the value of our approach by functional validation of a candidate agonist gene encoding a sterol regulatory element-binding protein (SREBP, which was identified by correlation analysis but not by pairwise comparison. We confirmed that SREBP promotes DENV infection in the midgut by RNAi-mediated gene knockdown in vivo. We suggest that our approach for transcriptomic analysis can empower genome-wide screens for potential agonist or antagonist factors by leveraging inter-individual variation in gene expression. More generally, this method is applicable to a wide range of phenotypic traits displaying inter-individual variation.

  11. Uniqueness conditions for constrained three-way factor decompositions with linearly dependent loadings

    NARCIS (Netherlands)

    Stegeman, Alwin; De Almeida, Andre L. F.

    2009-01-01

    In this paper, we derive uniqueness conditions for a constrained version of the parallel factor (Parafac) decomposition, also known as canonical decomposition (Candecomp). Candecomp/Parafac (CP) decomposes a three-way array into a prespecified number of outer product arrays. The constraint is that

  12. Comparison of Acceleration and Impact Stress as Possible Loading Factors in Phonation: A Computer Modeling Study

    Czech Academy of Sciences Publication Activity Database

    Horáček, Jaromír; Laukkanen, A. M.; Šidlof, Petr; Murphy, P.; Švec, J. G.

    2009-01-01

    Roč. 61, č. 3 (2009), s. 137-145 ISSN 1021-7762 R&D Projects: GA ČR(CZ) GA101/08/1155 Institutional research plan: CEZ:AV0Z20760514 Keywords : biomechanics of voice modeling * fundamental frequency * phoniation type * gender differences in voice Subject RIV: BI - Acoustics Impact factor: 1.439, year: 2007

  13. Using a latent variable model with non-constant factor loadings to examine PM2.5 constituents related to secondary inorganic aerosols.

    Science.gov (United States)

    Zhang, Zhenzhen; O'Neill, Marie S; Sánchez, Brisa N

    2016-04-01

    Factor analysis is a commonly used method of modelling correlated multivariate exposure data. Typically, the measurement model is assumed to have constant factor loadings. However, from our preliminary analyses of the Environmental Protection Agency's (EPA's) PM 2.5 fine speciation data, we have observed that the factor loadings for four constituents change considerably in stratified analyses. Since invariance of factor loadings is a prerequisite for valid comparison of the underlying latent variables, we propose a factor model that includes non-constant factor loadings that change over time and space using P-spline penalized with the generalized cross-validation (GCV) criterion. The model is implemented using the Expectation-Maximization (EM) algorithm and we select the multiple spline smoothing parameters by minimizing the GCV criterion with Newton's method during each iteration of the EM algorithm. The algorithm is applied to a one-factor model that includes four constituents. Through bootstrap confidence bands, we find that the factor loading for total nitrate changes across seasons and geographic regions.

  14. Associations between Dietary Acid-Base Load and Cardiometabolic Risk Factors in Adults: The Tehran Lipid and Glucose Study

    Directory of Open Access Journals (Sweden)

    Zahra Bahadoran

    2015-06-01

    Full Text Available BackgroundIn this study we investigated the associations of dietary acid-base load, identified by potential renal acid load (PRAL and protein to potassium (Pro:K ratio, with cardiometabolic risk factors in Tehranian adults.MethodsA cross-sectional study was conducted within the framework of the fourth phase of the Tehran Lipid and Glucose Study (2009 to 2011 on 5,620 men and women aged 19 to 70 years. Dietary data were collected by a trained dietitian using a validated, 147-food item, semi-quantitative food frequency questionnaire, and dietary PRAL and Pro:K ratio were calculated. Multiple linear regression models with adjustment for potential confounding variables were used to evaluate the associations of dietary acid-base load with anthropometric measures, blood pressure, serum triglycerides, high density lipoprotein cholesterol (HDL-C, serum creatinine, and fasting blood glucose.ResultsThe mean±SD age of the participants was 39.8±12.8 years and 54% of participants were women. Mean±SD PRAL was -22.0±29.1; mean PRAL was -15.6 in men and -26.8 in women. Dietary PRAL was associated with weight (β=0.098, P<0.001, waist circumference (β=0.062, P<0.01, serum triglycerides (β=0.143, P<0.01, HDL-C (β=-0.11, P<0.01, diastolic blood pressure (β=0.062, P<0.01, and serum creatinine (β=0.142, P<0.001. Pro:K ratio was associated with weight (β=0.055, P<0.001, waist circumference (β=0.04, P<0.01, serum HDL-C (β=-0.06, P<0.01, serum triglycerides (β=0.03, P<0.05, diastolic blood pressure (β=0.026, P<0.05, and serum creatinine (β=0.07, P<0.01.ConclusionA more acidic dietary acid-base load may be a risk factor for the development of metabolic disorders.

  15. Factors Controlling Nitrogen Loadings in Major River Basins Across the United States

    Science.gov (United States)

    Boyer, E. W.; Alexander, R. B.; Galloway, J. N.; Golden, H. E.; Moore, R. B.; Schwarz, G. E.; Harvey, J. W.; Gomez-Velez, J. D.; Scott, D.; Clune, J.

    2017-12-01

    Inputs of reactive nitrogen (all N species except for N2) have been increasing worldwide, largely due to human activities associated with food production and energy consumption via the combustion of fossil fuels and biofuels. Despite the obvious essential benefits of a plentiful supply of food and energy, the adverse consequences associated with the accumulation of N in the environment are large. Most of the N created by human activities is released to the environment, often with unintended negative consequences. The greater the inputs of N to the landscape, the greater the potential for negative effects - caused by greenhouse gas production, ground level ozone, acid deposition, and N overload; which in turn can contribute to climate change, degradation of soils and vegetation, acidification of surface waters, coastal eutrophication, hypoxia, habitat loss, and loss of stratospheric ozone. Here we present a contemporary inventory of reactive N inputs to major water regions in the United States, and discuss accounting methods for quantifying N sources and transport. Furthermore, we quantify loadings of N from terrestrial headwaters downstream to coastal estuaries and embayments. N delivery to downstream waters is influenced by nutrient sources as well as coupled hydrological and biogeochemical processes occurring along the river corridor (e.g., travel time distributions, denitrification, and storage) that scale with stream size and are affected by impoundments such as lakes and reservoirs. This underscores the need to account for the nonlinear interactions of aquatic transport processes with watershed nutrient sources, as well as cumulative effects, in developing efficient nutrient reduction strategies. Our work is useful as a benchmark of the current N situation against which future progress can be assessed in varying water regions of the country; amidst changing N inputs, policies, and management strategies. Our results stem from the EPA Integrated Nitrogen

  16. Structural basis for antagonizing a host restriction factor by C7 family of poxvirus host-range proteins.

    Science.gov (United States)

    Meng, Xiangzhi; Krumm, Brian; Li, Yongchao; Deng, Junpeng; Xiang, Yan

    2015-12-01

    Human sterile alpha motif domain-containing 9 (SAMD9) protein is a host restriction factor for poxviruses, but it can be overcome by some poxvirus host-range proteins that share homology with vaccinia virus C7 protein. To understand the mechanism of action for this important family of host-range factors, we determined the crystal structures of C7 and myxoma virus M64, a C7 family member that is unable to antagonize SAMD9. Despite their different functions and only 23% sequence identity, the two proteins have very similar overall structures, displaying a previously unidentified fold comprised of a compact 12-stranded antiparallel β-sandwich wrapped in two short α helices. Extensive structure-guided mutagenesis of C7 identified three loops clustered on one edge of the β sandwich as critical for viral replication and binding with SAMD9. The loops are characterized with functionally important negatively charged, positively charged, and hydrophobic residues, respectively, together forming a unique "three-fingered molecular claw." The key residues of the claw are not conserved in two C7 family members that do not antagonize SAMD9 but are conserved in distantly related C7 family members from four poxvirus genera that infect diverse mammalian species. Indeed, we found that all in the latter group of proteins bind SAMD9. Taken together, our data indicate that diverse mammalian poxviruses use a conserved molecular claw in a C7-like protein to target SAMD9 and overcome host restriction.

  17. Detour factors in water and plastic phantoms and their use for range and depth scaling in electron-beam dosimetry

    International Nuclear Information System (INIS)

    Fernandez-Varea, J.M.; Andreo, P.; Tabata, T.

    1996-01-01

    Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour factors from alternative definitions previously proposed in the literature. Different procedures used in low-energy electron-beam dosimetry to convert ranges and depths measured in plastic phantoms into water-equivalent ranges and depths are analysed. A new simple and accurate scaling method, based on Monte Carlo-derived ratios of average electron penetration depths and thus incorporating the effect of multiple scattering, is presented. Data are given for most plastics used in electron-beam dosimetry together with a fit which extends the method to any other low-Z plastic material. A study of scaled depth - dose curves and mean energies as a function of depth for some plastics of common usage shows that the method improves the consistency and results of other scaling procedures in dosimetry with electron beams at therapeutic energies. (author)

  18. Factors affecting the stability of drug-loaded polymeric micelles and strategies for improvement

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Weisai; Li, Caibin; Wang, Zhiyu; Zhang, Wenli, E-mail: zwllz@163.com; Liu, Jianping, E-mail: liujianpingljp@hotmail.com [China Pharmaceutical University, Department of Pharmaceutics (China)

    2016-09-15

    Polymeric micelles (PMs) self-assembled by amphiphilic block copolymers have been used as promising nanocarriers for tumor-targeted delivery due to their favorable properties, such as excellent biocompatibility, prolonged circulation time, favorable particle sizes (10–100 nm) to utilize enhanced permeability and retention effect and the possibility for functionalization. However, PMs can be easily destroyed due to dilution of body fluid and the absorption of proteins in system circulation, which may induce drug leakage from these micelles before reaching the target sites and compromise the therapeutic effect. This paper reviewed the factors that influence stability of micelles in terms of thermodynamics and kinetics consist of the critical micelle concentration of block copolymers, glass transition temperature of hydrophobic segments and polymer–polymer and polymer–cargo interaction. In addition, some effective strategies to improve the stability of micelles were also summarized.Graphical Abstract.

  19. Characterization and Evaluation of 600 V Range Devices for Active Power Factor Correction in Boundary and Continuous Conduction Modes

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Petersen, Lars Press; Andersen, Michael A. E.

    2015-01-01

    Traditional characterization of semiconductors switching dynamics is performed based on clamped inductive load measurements using the double pulse tester (DPT) configuration. This approach is valid for converters operating in continuous conduction mode (CCM), however in boundary conduction mode...

  20. Two factors influencing dose reconstruction in low dose range: the variability of BKG intensity on one individual and water content

    International Nuclear Information System (INIS)

    Zhang, Tengda; Zhang, Wenyi; Zhao, Zhixin; Zhang, Haiying; Ruan, Shuzhou; Jiao, Ling

    2016-01-01

    A fast and accurate retrospective dosimetry method for the triage is very important in radiation accidents. Electron paramagnetic resonance (EPR) fingernail dosimetry is a promising way to estimate radiation dose. This article presents two factors influencing dose reconstruction in low dose range: the variability of background signal (BKG) intensity on one individual and water content. Comparing the EPR spectrum of dried and humidified fingernail samples, it is necessary to add a procedure of dehydration before EPR measurements, so as to eliminate the deviation caused by water content. Besides, the BKGs of different fingers' nails are not the same as researchers thought previously, and the difference between maximum and minimum BKG intensities of one individual can reach 55.89 %. Meanwhile, the variability of the BKG intensity among individuals is large enough to impact precise dose reconstruction. Water within fingernails and instability of BKG are two reasons that cause the inaccuracy of radiation dose reconstruction in low-dosage level. (authors)

  1. Multiscale Thermohydrologic Model Analyses of Heterogeneity and Thermal-Loading Factors for the Proposed Repository at Yucca Mountain

    International Nuclear Information System (INIS)

    Glascoe, L.G.; Buscheck, T.A.; Gansemer, J.; Sun, Y.; Lee, K.

    2002-01-01

    The MultiScale ThermoHydrologic Model (MSTHM) predicts thermohydrologic (TH) conditions in emplacement drifts and the adjoining host rock throughout the proposed nuclear-waste repository at Yucca Mountain. The MSTHM is a computationally efficient approach that accounts for TH processes occurring at a scale of a few tens of centimeters around individual waste packages and emplacement drifts, and for heat flow at the multi-kilometer scale at Yucca Mountain. The modeling effort presented here is an early investigation of the repository and is simulated at a lower temperature mode and with a different panel loading than the repository currently being considered for license application. We present these recent lower temperature mode MSTHM simulations that address the influence of repository-scale thermal-conductivity heterogeneity and the influence of preclosure operational factors affecting thermal-loading conditions. We can now accommodate a complex repository layout with emplacement drifts lying in non-parallel planes using a superposition process that combines results from multiple mountain-scale submodels. This development, along with other improvements to the MSTHM, enables more rigorous analyses of preclosure operational factors. These improvements include the ability to (1) predict TH conditions on a drift-by-drift basis, (2) represent sequential emplacement of waste packages along the drifts, and (3) incorporate distance- and time-dependent heat-removal efficiency associated with drift ventilation. Alternative approaches to addressing repository-scale thermal-conductivity heterogeneity are investigated. We find that only one of the four MSTHM submodel types needs to incorporate thermal-conductivity heterogeneity. For a particular repository design, we find that the most influential parameters are (1) percolation-flux distribution, (2) thermal-conductivity heterogeneity within the host-rock units, (3) the sequencing of waste-package emplacement, and (4) the

  2. A hybrid filter to mitigate harmonics caused by nonlinear load and resonance caused by power factor correction capacitor

    Science.gov (United States)

    Adan, N. F.; Soomro, D. M.

    2017-01-01

    Power factor correction capacitor (PFCC) is commonly installed in industrial applications for power factor correction (PFC). With the expanding use of non-linear equipment such as ASDs, power converters, etc., power factor (PF) improvement has become difficult due to the presence of harmonics. The resulting capacitive impedance of the PFCC may form a resonant circuit with the source inductive reactance at a certain frequency, which is likely to coincide with one of the harmonic frequency of the load. This condition will trigger large oscillatory currents and voltages that may stress the insulation and cause subsequent damage to the PFCC and equipment connected to the power system (PS). Besides, high PF cannot be achieved due to power distortion. This paper presents the design of a three-phase hybrid filter consisting of a single tuned passive filter (STPF) and shunt active power filter (SAPF) to mitigate harmonics and resonance in the PS through simulation using PSCAD/EMTDC software. SAPF was developed using p-q theory. The hybrid filter has resulted in significant improvement on both total harmonic distortion for voltage (THDV) and total demand distortion for current (TDDI) with maximum values of 2.93% and 9.84% respectively which were within the recommended IEEE 519-2014 standard limits. Regarding PF improvement, the combined filters have achieved PF close to desired PF at 0.95 for firing angle, α values up to 40°.

  3. Sex, Diet, and the Social Environment: Factors Influencing Hair Cortisol Concentration in Free-Ranging Black Bears (Ursus americanus).

    Science.gov (United States)

    Lafferty, Diana J R; Laudenslager, Mark L; Mowat, Garth; Heard, Doug; Belant, Jerrold L

    2015-01-01

    Increasingly, measures of glucocorticoid levels (e.g., cortisol), key components of the neuroendocrine stress axis, are being used to measure past hypothalamic-pituitary-adrenal (HPA) activity to index psychological and physiological stress exhibited by wildlife for assessing individual and population-level well-being. However, many intrinsic and extrinsic factors affect HPA activity in animals. Using American black bears (Ursus americanus; n = 116) as an ecological model and hair cortisol concentration (HCC) as an integrative measure of past HPA activity, we evaluated the influence of diet, sex and the social environment on black bear HCC in a free-ranging population that spanned adjoining ecoregions with differing densities of potential conspecific and heterospecific competitors. HCC varied by sex, with female HCC ranging from 0.6 to 10.7 pg/mg (median = 4.5 ± 1.2 mean absolute deviation [MAD]) and male HCC ranging from 0.5 to 35.1 pg/mg (median = 6.2 ± 2.6 MAD). We also observed a three-way interaction among sex, δ14C and ecoregion, which may indicate that some differences in HCC between female and male black bears results from variability in the nutritional needs of larger-bodied males relative to smaller-bodied females, slight differences in food resources use between ecoregions as well as sex-based differences regarding the social environment. Once we understand what drives sex-specific differences in HCC, HCC may aid our understanding of the physiological responses by bears and other wildlife to diverse environmental challenges.

  4. Sex, Diet, and the Social Environment: Factors Influencing Hair Cortisol Concentration in Free-Ranging Black Bears (Ursus americanus)

    Science.gov (United States)

    Lafferty, Diana J. R.; Laudenslager, Mark L.; Mowat, Garth; Heard, Doug; Belant, Jerrold L.

    2015-01-01

    Increasingly, measures of glucocorticoid levels (e.g., cortisol), key components of the neuroendocrine stress axis, are being used to measure past hypothalamic-pituitary-adrenal (HPA) activity to index psychological and physiological stress exhibited by wildlife for assessing individual and population-level well-being. However, many intrinsic and extrinsic factors affect HPA activity in animals. Using American black bears (Ursus americanus; n = 116) as an ecological model and hair cortisol concentration (HCC) as an integrative measure of past HPA activity, we evaluated the influence of diet, sex and the social environment on black bear HCC in a free-ranging population that spanned adjoining ecoregions with differing densities of potential conspecific and heterospecific competitors. HCC varied by sex, with female HCC ranging from 0.6 to 10.7 pg/mg (median = 4.5 ± 1.2 mean absolute deviation [MAD]) and male HCC ranging from 0.5 to 35.1 pg/mg (median = 6.2 ± 2.6 MAD). We also observed a three-way interaction among sex, δ14C and ecoregion, which may indicate that some differences in HCC between female and male black bears results from variability in the nutritional needs of larger-bodied males relative to smaller-bodied females, slight differences in food resources use between ecoregions as well as sex-based differences regarding the social environment. Once we understand what drives sex-specific differences in HCC, HCC may aid our understanding of the physiological responses by bears and other wildlife to diverse environmental challenges. PMID:26529405

  5. Sex, Diet, and the Social Environment: Factors Influencing Hair Cortisol Concentration in Free-Ranging Black Bears (Ursus americanus.

    Directory of Open Access Journals (Sweden)

    Diana J R Lafferty

    Full Text Available Increasingly, measures of glucocorticoid levels (e.g., cortisol, key components of the neuroendocrine stress axis, are being used to measure past hypothalamic-pituitary-adrenal (HPA activity to index psychological and physiological stress exhibited by wildlife for assessing individual and population-level well-being. However, many intrinsic and extrinsic factors affect HPA activity in animals. Using American black bears (Ursus americanus; n = 116 as an ecological model and hair cortisol concentration (HCC as an integrative measure of past HPA activity, we evaluated the influence of diet, sex and the social environment on black bear HCC in a free-ranging population that spanned adjoining ecoregions with differing densities of potential conspecific and heterospecific competitors. HCC varied by sex, with female HCC ranging from 0.6 to 10.7 pg/mg (median = 4.5 ± 1.2 mean absolute deviation [MAD] and male HCC ranging from 0.5 to 35.1 pg/mg (median = 6.2 ± 2.6 MAD. We also observed a three-way interaction among sex, δ14C and ecoregion, which may indicate that some differences in HCC between female and male black bears results from variability in the nutritional needs of larger-bodied males relative to smaller-bodied females, slight differences in food resources use between ecoregions as well as sex-based differences regarding the social environment. Once we understand what drives sex-specific differences in HCC, HCC may aid our understanding of the physiological responses by bears and other wildlife to diverse environmental challenges.

  6. Drift Reliability Assessment of a Four Storey Frame Residential Building Under Seismic Loading Considering Multiple Factors

    Science.gov (United States)

    Sil, Arjun; Longmailai, Thaihamdau

    2017-09-01

    The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.

  7. Lipid-load in peripheral blood mononuclear cells: Impact of food-consumption, dietary-macronutrients, extracellular lipid availability and demographic factors.

    Science.gov (United States)

    Ameer, Fatima; Munir, Rimsha; Usman, Hina; Rashid, Rida; Shahjahan, Muhammad; Hasnain, Shahida; Zaidi, Nousheen

    2017-04-01

    Lipid-load in peripheral blood mononuclear cells (PBMCs) has recently gained attention of the researchers working on nutritional regulation of metabolic health. Previous works have indicated that the metabolic circuitries in the circulating PBMCs are influenced by dietary-intake and macronutrient composition of diet. In the present work, we analyzed the impact of diet and dietary macronutrients on PBMCs' lipid-load. The overall analyses revealed that dietary carbohydrates and fats combinatorially induce triglyceride accumulation in PBMCs. On the other hand, dietary fats were shown to induce significant decrease in PBMCs' cholesterol-load. The effects of various demographic factors -including age, gender and body-weight- on PBMCs' lipid-load were also examined. Body-weight and age were both shown to affect PBMC's lipid-load. Our study fails to provide any direct association between extracellular lipid availability and cholesterol-load in both, freshly isolated and cultured PBMCs. The presented work significantly contributes to the current understanding of the impact of food-consumption, dietary macronutrients, extracellular lipid availability and demographic factors on lipid-load in PBMCs. Copyright © 2017 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.

  8. Shot loading platform analysis

    International Nuclear Information System (INIS)

    Norman, B.F.

    1994-01-01

    This document provides the wind/seismic analysis and evaluation for the shot loading platform. Hand calculations were used for the analysis. AISC and UBC load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met

  9. National implementation of the UNECE convention on long-range transboundary air pollution (effects). Pt. 2. Impacts and risk estimation, critical loads, biodiversity, dynamic modelling, critical level violation, material corrosion; Nationale Umsetzung UNECE-Luftreinhaltekonvention (Wirkungen). T. 2. Wirkungen und Risikoabschaetzungen Critical Loads, Biodiversitaet, Dynamische Modellierung, Critical Levels Ueberschreitungen, Materialkorrosion

    Energy Technology Data Exchange (ETDEWEB)

    Gauger, Thomas [Bundesforschungsanstalt fuer Landwirtschaft, Braunschweig (DE). Inst. fuer Agraroekologie (FAL-AOE); Stuttgart Univ. (Germany). Inst. fuer Navigation; Haenel, Hans-Dieter; Roesemann, Claus [Bundesforschungsanstalt fuer Landwirtschaft, Braunschweig (DE). Inst. fuer Agraroekologie (FAL-AOE); Nagel, Hans-Dieter; Becker, Rolf; Kraft, Philipp; Schlutow, Angela; Schuetze, Gudrun; Weigelt-Kirchner, Regine [OeKO-DATA Gesellschaft fuer Oekosystemanalyse und Umweltdatenmanagement mbH, Strausberg (Germany); Anshelm, Frank [Geotechnik Suedwest Frey Marx GbR, Bietigheim-Bissingen (Germany)

    2008-09-15

    The report on the implementation of the UNECE convention on long-range transboundary air pollution Pt.2 covers the following issues: The tasks of the NFC (National Focal Center) Germany including the ICP (international cooperative program) modeling and mapping and the expert panel for heavy metals. Results of the work for the multi-component protocol cover the initial data for the calculation of the critical loads following the mass balance method, critical loads for acid deposition, critical loads for nitrogen input, critical load violations (sulfur, nitrogen). The results of work for the heavy metal protocol cover methodology development and recommendations for ICO modeling and mapping in accordance with international development, contributions of the expert group/ task force on heavy metals (WGSR), data sets on the critical loads for lead, cadmium and mercury, and critical load violations (Pb, Cd, Hg). The results of work on the inclusion of biodiversity (BERN) cover data compilation, acquisition and integration concerning ecosystems, model validation and verification and the possible interpretation frame following the coupling with dynamic modeling. The future development and utilization of dynamic modeling covers model comparison, applicability, the preparation of a national data set and preparations concerning the interface to the BERN model.

  10. A ORACLE-based system for data collection, storage and analysis of main equipment load factors in NPPs and TPPs

    International Nuclear Information System (INIS)

    Ivanova, L.

    1993-01-01

    This data base is developed by the National Electricity Company, Sofia (BG) as an aid to supervision, analysis and administration decision making in a variety of operational situations in NPPs and TPPs. As major indicators of the equipment condition the following primary data are stored: steam or electricity production per month; operation hours per month; equipment stand-by outages; planned outages; unplanned permitted maintenance outages; unplanned emergency maintenance outages; number of outages of the unit per month. These data cover the period from the putting of the corresponding equipment into operation till the present moment, i.e. or about 32 years. The data up to 1990 are annual and for the last three years - monthly. Based on these primary data, the following quantities are calculated: average capacity; average load factors; operation time factors - total and accounting for the planned and the permitted unplanned outages; unpermitted outages factors - total and accounting for the planned and the permitted outages. All the factors are calculated on user's request for a chosen time period, by summing up correspondingly the major indicators (production, operation hours and various outages) for the given period. The system operates on an IBM 4341 under VM/SP and DB ORACLE V.5. The input is entered directly from the TPP and NPP by telex lines from PCs, operating also as telex machines, into the mainframe of Energokibernetika Ltd. They are available to all authorised users from local terminals or PCs, connected to the computer by synchronous or asynchronous lines. A system for data transmission to remote users along commutated telephone lines is also developed. (R. Ts.)

  11. Dynamic behaviour of a planar micro-beam loaded by a fluid-gap: Analytical and numerical approach in a high frequency range, benchmark solutions

    Science.gov (United States)

    Novak, A.; Honzik, P.; Bruneau, M.

    2017-08-01

    Miniaturized vibrating MEMS devices, active (receivers or emitters) or passive devices, and their use for either new applications (hearing, meta-materials, consumer devices,…) or metrological purposes under non-standard conditions, are involved today in several acoustic domains. More in-depth characterisation than the classical ones available until now are needed. In this context, the paper presents analytical and numerical approaches for describing the behaviour of three kinds of planar micro-beams of rectangular shape (suspended rigid or clamped elastic planar beam) loaded by a backing cavity or a fluid-gap, surrounded by very thin slits, and excited by an incident acoustic field. The analytical approach accounts for the coupling between the vibrating structure and the acoustic field in the backing cavity, the thermal and viscous diffusion processes in the boundary layers in the slits and the cavity, the modal behaviour for the vibrating structure, and the non-uniformity of the acoustic field in the backing cavity which is modelled in using an integral formulation with a suitable Green's function. Benchmark solutions are proposed in terms of beam motion (from which the sensitivity, input impedance, and pressure transfer function can be calculated). A numerical implementation (FEM) is handled against which the analytical results are tested.

  12. Scratch that itch: revisiting links between self-directed behaviour and parasitological, social and environmental factors in a free-ranging primate.

    Science.gov (United States)

    Duboscq, Julie; Romano, Valéria; Sueur, Cédric; MacIntosh, Andrew J J

    2016-11-01

    Different hypotheses explain variation in the occurrence of self-directed behaviour such as scratching and self-grooming: a parasite hypothesis linked with ectoparasite load, an environmental hypothesis linked with seasonal conditions and a social hypothesis linked with social factors. These hypotheses are not mutually exclusive but are often considered separately. Here, we revisited these hypotheses together in female Japanese macaques ( Macaca fuscata fuscata ) of Kōjima islet, Japan. We input occurrences of scratching and self-grooming during focal observations in models combining parasitological (lice load), social (dominance rank, social grooming, aggression received and proximity), and environmental (rainfall, temperature and season) variables. Using an information-theory approach, we simultaneously compared the explanatory value of models against each other using variation in Akaike's information criterion and Akaike's weights. We found that evidence for models with lice load, with or without environmental-social parameters, was stronger than that for other models. In these models, scratching was positively associated with lice load and social grooming whereas self-grooming was negatively associated with lice load and positively associated with social grooming, dominance rank and number of female neighbours. This study indicates that the study animals scratch primarily because of an immune/stimulus itch, possibly triggered by ectoparasite bites/movements. It also confirms that self-grooming could act as a displacement activity in the case of social uncertainty. We advocate that biological hypotheses be more broadly considered even when investigating social processes, as one does not exclude the other.

  13. Optimization of 10 kW solar photovoltaic – diesel generator hybrid energy system for different load factors at Jaisalmer location of Rajasthan, India

    Science.gov (United States)

    Saraswat, S. K.; Rao, K. V. S.

    2018-03-01

    Jaisalmer town in Rajasthan, India is having annual average solar insolation of 5.80 kWh/m2/day and 270 – 300 clear sky days in a year. A 10 kW off-grid hybrid energy system (HES) consisting of solar photovoltaic panels – diesel generator – bidirectional converter and batteries with zero percentage loss of load for Jaisalmer is designed using HOMER (version 3.4.3) software. Different system load factors of 0.33, 0.50, 0.67, 0.83 and 1 corresponding to fraction of running hours per day of the system are considered. The system is analyzed for all three aspects, namely, electrical, economic and emission point of view. Least levelized cost of electricity (LCOE) of Rs. 8.43/kWh is obtained at a load factor value of 0.5. If diesel generator alone (without Solar PV) is used to fulfil the demand for a load factor of 0.5the value of LCOE is obtained Rs.19.23/kWh. Comparison of results obtained for HES and diesel generator are made for load factor of 0.5 and 1.

  14. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    Science.gov (United States)

    Al-Degs, Yahya; Andri, Bertyl; Thiébaut, Didier; Vial, Jérôme

    2017-01-01

    Retention mechanisms involved in supercritical fluid chromatography (SFC) are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase), a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC) was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition). Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition) data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns' function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components. PMID:28695040

  15. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    Directory of Open Access Journals (Sweden)

    Ramia Z. Al Bakain

    2017-01-01

    Full Text Available Retention mechanisms involved in supercritical fluid chromatography (SFC are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase, a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition. Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns’ function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components.

  16. Regulation of the Dynamic Live Load Factor for Calculation of Bridge Structures on High-Speed Railway Mainlines

    Science.gov (United States)

    Dyachenko, Leonid K.; Benin, Andrey V.

    2017-06-01

    When the high-speed railway traffic is being organized, it becomes necessary to elaborate bridge design standards for high-speed railways (HSR). Methodology of studying the issues of HSR bridge design is based on the comprehensive analysis of domestic research as well as international experience in design, construction and operation of high-speed railways. Serious requirements are imposed on the HSR artificial structures, which raise a number of scientific tasks associated mainly with the issues of the dynamic interaction of the rolling stock and the bridge elements. To ensure safety of traffic and reliability of bridges during the whole period of operation one needs to resolve the dynamic problems of various types of high-speed trains moving along the structures. The article analyses dependences of the magnitude of inertial response on the external stress parameters and proposes a simplified method of determination of the dynamic live load factor caused by the passage of high-speed trains. The usefulness of the given research arises from the reduction of complexity of the complicated dynamic calculations needed to describe a high-speed train travelling along the artificial structures.

  17. Regulation of the Dynamic Live Load Factor for Calculation of Bridge Structures on High-Speed Railway Mainlines

    Directory of Open Access Journals (Sweden)

    Dyachenko Leonid K.

    2017-06-01

    Full Text Available When the high-speed railway traffic is being organized, it becomes necessary to elaborate bridge design standards for high-speed railways (HSR. Methodology of studying the issues of HSR bridge design is based on the comprehensive analysis of domestic research as well as international experience in design, construction and operation of high-speed railways. Serious requirements are imposed on the HSR artificial structures, which raise a number of scientific tasks associated mainly with the issues of the dynamic interaction of the rolling stock and the bridge elements. To ensure safety of traffic and reliability of bridges during the whole period of operation one needs to resolve the dynamic problems of various types of high-speed trains moving along the structures. The article analyses dependences of the magnitude of inertial response on the external stress parameters and proposes a simplified method of determination of the dynamic live load factor caused by the passage of high-speed trains. The usefulness of the given research arises from the reduction of complexity of the complicated dynamic calculations needed to describe a high-speed train travelling along the artificial structures.

  18. Related factors to atazanavir plasma levels in a cohort of HIV positive individuals with undetectable viral load

    Directory of Open Access Journals (Sweden)

    Ana Júlia Luz

    Full Text Available OBJECTIVE: To evaluate the factors associated with plasma concentrations of atazanavir (ATV in a cohort of well-controlled HIV infected subjects (undetectable viremia. Design: Cross-sectional study where 69 subjects were consecutively enrolled between April and November, 2011. METHODS: Patients had to be on atazanavir for at least six months, undetectable viral load for a period equal to or longer than 12 months, T CD4+ lymphocyte count higher than 200 cells/mm³, and aged between 18 years and 70 years old. Exclusion criteria were pregnancy, any neurologic disease, active opportunistic disease, hepatitis or cancer. Atazanavir plasma levels were measured by ultra-performance liquid chromatography. RESULTS AND DISCUSSION: Overall, 54 patients (mean age of 47 years and 50% women were included in the analysis. Those without ritonavir (unboosted atazanavir had statistically lower plasma concentrations than those with ritonavir boosted atazanavir (p = 0.001 and total and indirect bilirubin were statistically associated with plasma concentration of atazanavir (r = 0.32 and r = 0.33 respectively; p < 0.05 in both cases. no statistical association was found among gender, ethnicity, age, weight, body mass index (BMI, lipid profile, and the plasma concentration of atazanavir. CONCLUSION: in summary, as expected, concomitant ritonavir use was the only factor associated with atazanavir plasma levels. prospective studies with a larger sample size might help to observe an association of atazanavir concentrations to other characteristics such as body weight, since the p-value showed to be close to significance (p = 0.068.

  19. Pigment epithelial-derived factor gene loaded novel COOH-PEG-PLGA-COOH nanoparticles promoted tumor suppression by systemic administration.

    Science.gov (United States)

    Yu, Ting; Xu, Bei; He, Lili; Xia, Shan; Chen, Yan; Zeng, Jun; Liu, Yongmei; Li, Shuangzhi; Tan, Xiaoyue; Ren, Ke; Yao, Shaohua; Song, Xiangrong

    2016-01-01

    Anti-angiogenesis has been proposed as an effective therapeutic strategy for cancer treatment. Pigment epithelium-derived factor (PEDF) is one of the most powerful endogenous anti-angiogenic reagents discovered to date and PEDF gene therapy has been recognized as a promising treatment option for various tumors. There is an urgent need to develop a safe and valid vector for its systemic delivery. Herein, a novel gene delivery system based on the newly synthesized copolymer COOH-PEG-PLGA-COOH (CPPC) was developed in this study, which was probably capable of overcoming the disadvantages of viral vectors and cationic lipids/polymers-based nonviral carriers. PEDF gene loaded CPPC nanoparticles (D-NPs) were fabricated by a modified double-emulsion water-in-oil-in-water (W/O/W) solvent evaporation method. D-NPs with uniform spherical shape had relatively high drug loading (~1.6%), probably because the introduced carboxyl group in poly (D,L-lactide-co-glycolide) terminal enhanced the interaction of copolymer with the PEDF gene complexes. An excellent in vitro antitumor effect was found in both C26 and A549 cells treated by D-NPs, in which PEDF levels were dramatically elevated due to the successful transfection of PEDF gene. D-NPs also showed a strong inhibitory effect on proliferation of human umbilical vein endothelial cells in vitro and inhibited the tumor-induced angiogenesis in vivo by an alginate-encapsulated tumor cell assay. Further in vivo antitumor investigation, carried out in a C26 subcutaneous tumor model by intravenous injection, demonstrated that D-NPs could achieve a significant antitumor activity with sharply reduced microvessel density and significantly promoted tumor cell apoptosis. Additionally, the in vitro hemolysis analysis and in vivo serological and biochemical analysis revealed that D-NPs had no obvious toxicity. All the data indicated that the novel CPPC nanoparticles were ideal vectors for the systemic delivery of PEDF gene and might be widely

  20. Calculating load factors for the transatlantic airline market using supply and demand data: a note on the identification of gaps in the available airline statistics

    NARCIS (Netherlands)

    Devriendt, L.; Burghouwt, G.; Derudder, B.; de Wit, J.; Witlox, F.

    2009-01-01

    This paper takes a critical view of the verification of load factors for the direct transatlantic airline market by combining supply and demand-data. The supply-related data originate from the Official Airline Guide, a well-known data source that contains information on scheduled flights. The

  1. Factors influencing storm-generated suspended-sediment concentrations and loads in four basins of contrasting land use, humid-tropical Puerto Rico

    Science.gov (United States)

    A. C. Gellis; NO-VALUE

    2013-01-01

    The significant characteristics controlling the variability in storm-generated suspended-sediment loads and concentrations were analyzed for four basins of differing land use (forest, pasture, cropland, and urbanizing) in humid-tropical Puerto Rico. Statistical analysis involved stepwise regression on factor scores. The explanatory variables were attributes of flow,...

  2. Glycemic index and glycemic load are associated with some cardiovascular risk factors among the PREMIER study participants

    Directory of Open Access Journals (Sweden)

    Pao-Hwa Lin

    2012-06-01

    Full Text Available Background: The clinical significance of glycemic index (GI and glycemic load (GL is inconclusive. Objective : This study was conducted to examine the association of GI and GL with clinical cardiovascular disease (CVD risk factors including body weight, blood pressure (BP, serum lipids, fasting glucose, insulin and homocysteine over time among the PREMIER participants. Design: PREMIER was an 18-month randomized lifestyle intervention trial, conducted from 2000 to 2002, designed to help participants reduce BP by following the Dietary Approaches to Stop Hypertension (DASH dietary pattern, losing weight, reducing sodium and increasing physical activity. GI and GL were estimated from 24 h diet recall data at baseline, 6 and 18 months after intervention. PROC MIXED model was used to examine the association of changes in GI or GL with changes in CVD risk factors. Results: A total of 756 randomized participants, 62% females and 34% African Americans and who averaged 50.0±0.3 years old and 95.3±0.7 kg, were included in this report. Neither GI nor GL changes was associated with changes in any risk factors at 6 months. At 18 months, however, the GI change was significantly and positively associated with total cholesterol (TC change only (p<0.05, β = 23.80±12.11 mg/dL or 0.62±0.31 mmol/L with a significant age interaction. The GL change was significantly associated with TC (p=0.02, β = 0.28±0.15 mg/dL or 0.01±0.00 mmol/L positively and with low density lipoprotein cholesterol (LDL-C changes negatively (p=0.03, β = − 0.01±0.00 mg/dL or −0.00±0.00 mmol/L, and significant age interactions were observed for both. Conclusion: GI and GL was associated with TC and LDL-C after controlling for energy, fat and fiber intake and other potential confounders and the associations were modified by age. Further investigation into this relationship is important because of its potential clinical impact.

  3. Factors affecting the potential of direct load control for non-generating utilities. Final report. [Distribution and wholesale power supply interaction

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-04-01

    Several alternatives are available for achieving load management, including direct or voluntary control of customer loads, customer or utility energy storage systems for diurnal load shifting, and expanded interconnection and operation of electric power systems. All of these alternatives are available to the fully integrated (generating, transmitting and distributing) electric utility and the analysis of their effects encompasses the power supply and delivery system. However, the costs and benefits of the alternatives to the fully integrated electric utility are perhaps not so obvious. Therefore, by considering a non-generating utility, this analysis focuses upon the distribution system and wholesale power supply interaction as a step toward an analysis including the power supply and delivery system. This report develops an analysis procedure and discusses some of the relevant factors to be consdered in the application of direct load control for a non-generating utility system. The analysis concentrates on the distribution system only to determine the effect of rates and payback as a result of direct load control. Thus, the study is responsive to the specific needs of the non-generating utility. This analysis of direct load control encompasses the determination of those loads amenable to control, the selection of a suitable one-way communications system to rend control and the estimation of expected benefits and costs. The complementary functions to the application of direct load control such as automatic meter reading via the addition of a bi-directional communications system and voltage control are not included in the analysis but are detailed for future consideration.

  4. Gambogic acid-loaded magnetic Fe(3)O(4) nanoparticles inhibit Panc-1 pancreatic cancer cell proliferation and migration by inactivating transcription factor ETS1.

    Science.gov (United States)

    Wang, Cailian; Zhang, Haijun; Chen, Yan; Shi, Fangfang; Chen, Baoan

    2012-01-01

    E26 transformation-specific sequence-1 (ETS1) transcription factor plays important roles in both carcinogenesis and the progression of a wide range of malignancies. Aberrant ETS1 expression correlates with aggressive tumor behavior and a poorer prognosis in patients with various malignancies. The aim of the current study was to evaluate the efficacy of a drug delivery system utilizing gambogic acid-loaded magnetic Fe(3)O(4) nanoparticles (GA-MNP-Fe(3)O(4)) on the suppression of ETS1-mediated cell proliferation and migration in Panc-1 pancreatic cancer cells. The effects caused by GA-MNP-Fe(3)O(4) on the proliferation of Panc-1 pancreatic cancer cells were evaluated using a MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay while inhibition of tumor cell migration was investigated in a scratch assay. The expressions of ETS1, cyclin D1, urokinase-type plasminogen activator (u-PA), and VEGF (vascular endothelial growth factor) were examined by Western blot to elucidate the possible mechanisms involved. In Panc-1 pancreatic cancer cells, we observed that application of GA-MNP-Fe(3)O(4) was able to suppress cancer cell proliferation and prevent cells from migrating effectively. After treatment, Panc-1 pancreatic cancer cells showed significantly decreased expression of ETS1, as well as its downstream target genes for cyclin D1, u-PA, and VEGF. Our novel finding reaffirmed the significance of ETS1 in the treatment of pancreatic cancer, and application of GA-MNP-Fe(3)O(4) nanoparticles targeting ETS1 should be considered as a promising contribution for better pancreatic cancer care.

  5. Pigment epithelial-derived factor gene loaded novel COOH-PEG-PLGA-COOH nanoparticles promoted tumor suppression by systemic administration

    Directory of Open Access Journals (Sweden)

    Yu T

    2016-02-01

    Full Text Available Ting Yu,1,* Bei Xu,1,* Lili He,2 Shan Xia,3 Yan Chen,1 Jun Zeng,1 Yongmei Liu,1 Shuangzhi Li,1 Xiaoyue Tan,4 Ke Ren,1 Shaohua Yao,1 Xiangrong Song1 1State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, 2College of Chemistry and Environment Protection Engineering, Southwest University for Nationalities, 3Central Laboratory, Science Education Department, Chengdu Normal University, Chengdu, Sichuan, 4Department of Pathology/Collaborative Innovation Center of Biotherapy, Medical School of Nankai University, Tianjin, People’s Republic of China *These authors contributed equally to this work Abstract: Anti-angiogenesis has been proposed as an effective therapeutic strategy for cancer treatment. Pigment epithelium-derived factor (PEDF is one of the most powerful endogenous anti-angiogenic reagents discovered to date and PEDF gene therapy has been recognized as a promising treatment option for various tumors. There is an urgent need to develop a safe and valid vector for its systemic delivery. Herein, a novel gene delivery system based on the newly synthesized copolymer COOH-PEG-PLGA-COOH (CPPC was developed in this study, which was probably capable of overcoming the disadvantages of viral vectors and cationic lipids/polymers-based nonviral carriers. PEDF gene loaded CPPC nanoparticles (D-NPs were fabricated by a modified double-emulsion water-in-oil-in-water (W/O/W solvent evaporation method. D-NPs with uniform spherical shape had relatively high drug loading (~1.6%, probably because the introduced carboxyl group in poly (D,L-lactide-co-glycolide terminal enhanced the interaction of copolymer with the PEDF gene complexes. An excellent in vitro antitumor effect was found in both C26 and A549 cells treated by D-NPs, in which PEDF levels were dramatically elevated due to the successful transfection of PEDF gene. D-NPs also showed a strong inhibitory effect on

  6. Factors related to external loads in buried pipelines; Consideracoes quanto as variaveis relacionadas ao carregamento externo em dutos enterrados

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Carlos E.C.; Silva, Breno S.; Fernandes, Lincoln F.; Santos Junior, Sergio J.F. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Louzada, Carlos H.C.M.

    2005-07-01

    Work of heavy equipment or vehicles above existent right-of-ways, may cause undesired external overload at buried pipelines in operation. The effect of these loads shall be analyzed considering the deflections and stresses on the pipelines. The major variables, nominal diameter, thickness, material, soil parameters, operation pressure and external loads shall be related and verified according to the limits from original project. Cases when the external loads cause higher efforts, the traffic over the pipelines shall be restricted in order to avoid damages. In other cases, it may be adapted to any technical alternatives to modify the parameters in such a way to make possible work above the right-of-way, such as increase the machine support area, increase backfill covering, a reduction in the internal operation pressure in a short time, etc. This work presents the study on the parameters used to establish the maximum allowable external loads over buried pipelines in operation. (author)

  7. [Estimation of urban non-point source pollution loading and its factor analysis in the Pearl River Delta].

    Science.gov (United States)

    Liao, Yi-Shan; Zhuo, Mu-Ning; Li, Ding-Qiang; Guo, Tai-Long

    2013-08-01

    In the Pearl Delta region, urban rivers have been seriously polluted, and the input of non-point source pollution materials, such as chemical oxygen demand (COD), into rivers cannot be neglected. During 2009-2010, the water qualities at eight different catchments in the Fenjiang River of Foshan city were monitored, and the COD loads for eight rivulet sewages were calculated in respect of different rainfall conditions. Interesting results were concluded in our paper. The rainfall and landuse type played important roles in the COD loading, with greater influence of rainfall than landuse type. Consequently, a COD loading formula was constructed that was defined as a function of runoff and landuse type that were derived SCS model and land use map. Loading of COD could be evaluated and predicted with the constructed formula. The mean simulation accuracy for single rainfall event was 75.51%. Long-term simulation accuracy was better than that of single rainfall. In 2009, the estimated COD loading and its loading intensity were 8 053 t and 339 kg x (hm2 x a)(-1), and the industrial land was regarded as the main source of COD pollution area. The severe non-point source pollution such as COD in Fenjiang River must be paid more attention in the future.

  8. Factors associated with mother-to-child transmission of HIV-1 despite a maternal viral load EPF-ANRS CO1).

    Science.gov (United States)

    Tubiana, Roland; Le Chenadec, Jerome; Rouzioux, Christine; Mandelbrot, Laurent; Hamrene, Karima; Dollfus, Catherine; Faye, Albert; Delaugerre, Constance; Blanche, Stephane; Warszawski, Josiane

    2010-02-15

    The rate of mother-to-child transmission (MTCT) of human immunodeficiency virus (HIV) type 1 is as low as 0.5% in non-breast-feeding mothers who delivered at term while receiving antiretroviral therapy with a plasma viral load <500 copies/mL. This situation accounted for 20% of the infected children born during the period 1997-2006 in the French Perinatal Cohort. We aimed to identify factors associated with such residual transmission risk. We performed a case-control study nested in the aforementioned subpopulation of the French Perinatal Cohort. Nineteen case patients (transmitters) and 60 control subjects (nontransmitters) were included. Case patients and control subjects did not differ by geographical origin, gestational age at HIV diagnosis, type of antiretroviral therapy received, or elective Cesarean delivery. Case patients were less often receiving treatment at the time that they conceived pregnancy than control subjects (16% vs 45%; P=.017). A lower proportion of case patients had a viral load <500 copies/mL, compared with control subjects, at 14 weeks (0% vs 38.1%; P=.02), 28 weeks (7.7% vs 62.1%; P=.005), and 32 weeks: (21.4% vs 71.1%; P=.004). The difference remained significant when we restricted analysis to the 10 of 16 intrapartum transmission cases. In a multivariate analysis at 30+/-4 weeks adjusted for viral load, CD4(+) T cell count, and time at antiretroviral therapy initiation, viral load was the only factor independently associated with MTCT of HIV (adjusted odds ratio, 23.2; 95% confidence interval, 3.5-553; P<.001). Early and sustained control of viral load is associated with a decreasing residual risk of MTCT of HIV-1. Guidelines should take into account not only CD4(+) T cell count and risk of preterm delivery, but also baseline HIV-1 load for deciding when to start antiretroviral therapy during pregnancy.

  9. Shoulder range of motion measures as risk factors for shoulder and elbow injuries in high school softball and baseball players.

    Science.gov (United States)

    Shanley, Ellen; Rauh, Mitchell J; Michener, Lori A; Ellenbecker, Todd S; Garrison, J Craig; Thigpen, Charles A

    2011-09-01

    Range of motion deficits in shoulder external rotation (ER), internal rotation (IR), total rotation range of motion (ER + IR), and horizontal adduction (HA) have been retrospectively associated with overhand athletes' arm injuries. The authors expected the incidence of upper extremity injury in high school softball and baseball players with side-to-side shoulder range of motion deficits to be greater than the incidence of upper extremity injury in players with normal shoulder range of motion. Cohort study (prognosis); Level of evidence, 2. High school softball and baseball players (N = 246) participated. Before the start of the season, passive shoulder ER, IR, and HA were assessed at 90° of abduction with the scapula stabilized. Relative risk (RR) was calculated to examine range of motion measure, by categorical criteria, and risk of upper extremity injury. Twenty-seven shoulder and elbow injuries (9 softball, 18 baseball) were observed during the season. The dominant shoulder of all injured players and baseball players displayed a significant decrease in HA (P = .05) and IR (P = .04). The dominant shoulder total rotation of injured baseball players displayed a significant decrease (mean difference = 8.0° ± 0.1°; P = .05) as compared with the dominant shoulder of uninjured baseball players. Players who displayed a decrease of ≥25° of IR in the dominant shoulder were at 4 times greater risk of upper extremity injury compared with players with a .05). There are large mean deficits in shoulder IR and HA between injured and noninjured players, but not in ER or total rotation. Passive shoulder IR loss ≥25° as compared bilaterally was predictive of arm injury. Shoulder range of motion deficits differed between sports and appeared more predictive of injury for baseball players.

  10. Enhanced antidepressant-like effects of the macromolecule trefoil factor 3 by loading into negatively charged liposomes

    Directory of Open Access Journals (Sweden)

    Qin J

    2014-11-01

    Full Text Available Jing Qin,1 Xu Yang,1–3 Jia Mi,4 Jianxin Wang,1 Jia Hou,1,2 Teng Shen,1 Yongji Li,2 Bin Wang,4 Xuri Li,4 Weili Zhu5 1Department of Pharmaceutics, School of Pharmacy, Fudan University, Key Laboratory of Smart Drug Delivery, Ministry of Education, Shanghai, 2Department of Pharmaceutics, School of Pharmacy, Heilongjiang University of Chinese Medicine, Harbin, 3Department of Pharmacy, The Fifth People’s Hospital of Shanghai, Fudan University, Shanghai, 4Binzhou Medical University, Yantai, 5National Institute on Drug Dependence, Peking University, Beijing, People’s Republic of China Abstract: Immunocytes, mainly neutrophils and monocytes, exhibit an intrinsic homing property, enabling them to migrate to sites of injury and inflammation. They can thus act as Trojan horses carrying concealed drug cargoes while migrating across impermeable barriers to sites of disease, especially the blood–brain barrier (BBB. In this study, to target circulating phagocytic cells, we formulated negatively charged nanosize liposomes and loaded trefoil factor 3 (TFF3 into liposomes by the pH-gradient method. According to the optimized formulation (5:1.5 of lipid to cholesterol, 10:1 of lipid to drug, 10 mg/mL of lipid concentration, and 10 mmol/L of phosphate-buffered saline, 44.47% entrapment efficiency was obtained for TFF3 liposomes with 129.6 nm particle size and –36.6 mV zeta potential. Compared with neutrally charged liposomes, the negatively charged liposomes showed a strong binding capacity with monocytes and were effectively carried by monocytes to cross the BBB in vitro. Furthermore, enhanced antidepressant-like effects were found in the tail-suspension and forced-swim tests in mice, as measured by decreased immobility time, as well as increased swimming time and reduced immobility in rats. These results suggested that negatively charged liposomes could improve the behavioral responses of TFF3, and our study opens up a new way for the development of

  11. The role of the form factor and short-range correlation in the relativistic Hartree-Fock model for nuclear matter

    International Nuclear Information System (INIS)

    Hu, J.; Toki, H.; Wen, W.; Shen, H.

    2010-01-01

    The role of the form factor and short-range correlation in nuclear matter is studied within the relativistic Hartree-Fock approximation. We take, first, the mean-field approximation for meson fields and obtain the fluctuation terms of mesons to be used for the Fock energies. We introduce form factors in the meson-nucleon coupling vertices to take into account the finite-size effect of the nucleon. We use further the unitary correlation operator method for the treatment of the short-range correlation. The form factors of the size (Λ∝1.0 -2.0 GeV) of the nucleon-nucleon interaction cut down largely the contribution of the ρ-meson in the Fock term. The short-range correlation effect is not large but has a significant effect on the pion and ρ-meson energies in the relativistic Hartree-Fock approximation for nuclear matter. (orig.)

  12. The role of the form factor and short-range correlation in the relativistic Hartree-Fock model for nuclear matter

    Science.gov (United States)

    Hu, J.; Toki, H.; Wen, W.; Shen, H.

    2010-03-01

    The role of the form factor and short-range correlation in nuclear matter is studied within the relativistic Hartree-Fock approximation. We take, first, the mean-field approximation for meson fields and obtain the fluctuation terms of mesons to be used for the Fock energies. We introduce form factors in the meson-nucleon coupling vertices to take into account the finite-size effect of the nucleon. We use further the unitary correlation operator method for the treatment of the short-range correlation. The form factors of the size ( Λ ˜ 1.0 -2.0GeV) of the nucleon-nucleon interaction cut down largely the contribution of the ρ -meson in the Fock term. The short-range correlation effect is not large but has a significant effect on the pion and ρ -meson energies in the relativistic Hartree-Fock approximation for nuclear matter.

  13. Mechanical loading by fluid shear stress of myotube glycocalyx stimulates growth factor expression and nitric oxide production

    NARCIS (Netherlands)

    Juffer, P.; Bakker, A.D.; Klein-Nulend, J.; Jaspers, R.T.

    2014-01-01

    Skeletal muscle fibers have the ability to increase their size in response to a mechanical overload. Finite element modeling data suggest that mechanically loaded muscles in vivo may experience not only tensile strain but also shear stress. However, whether shear stress affects biological pathways

  14. Parasite load and risk factors for poor outcome among children with visceral leishmaniasis. A cohort study in Belo Horizonte, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Maria Vitória Assumpção Mourão

    2014-04-01

    Full Text Available Clinical and laboratory risk factors for death from visceral leishmaniasis (VL are relatively known, but quantitative real-time polymerase chain reaction (qPCR might assess the role of parasite load in determining clinical outcome. The aim of this study was to identify risk factors, including parasite load in peripheral blood, for VL poor outcome among children. This prospective cohort study evaluated children aged ≤ 12 years old with VL diagnosis at three times: pre-treatment (T0, during treatment (T1 and post-treatment (T2. Forty-eight patients were included and 16 (33.3% met the criteria for poor outcome. Age ≤ 12 months [relative risk (RR 3.51; 95% confidence interval (CI 1.89-6.52], tachydyspnoea (RR 3.46; 95% CI 2.19-5.47, bacterial infection (RR 3.08; 95% CI 1.27-7.48, liver enlargement (RR 3.00; 95% CI 1.44-6.23 and low serum albumin (RR 7.00; 95% CI 1.80-27.24 were identified as risk factors. qPCR was positive in all patients at T0 and the parasite DNA was undetectable in 76.1% of them at T1 and in 90.7% at T2. There was no statistical association between parasite load at T0 and poor outcome.

  15. Structure Factor of a Hard-core Fluid with Short-range Yukawa Attraction: Analytical FMSA Theory against Monte Carlo Simulations.

    Czech Academy of Sciences Publication Activity Database

    Melnyk, R.; Nezbeda, Ivo; Trokhymchuk, A.

    2016-01-01

    Roč. 114, 16-17 (2016), s. 2523-2529 ISSN 0026-8976 Institutional support: RVO:67985858 Keywords : hard-core fluid * reference system * short-range Yukawa attraction Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.870, year: 2016

  16. Serum Alanine Aminotransferase Levels within Normal Range Have Different Associations with Augmentation Index and Other Cardiometabolic Risk Factors in Nondrinkers and Drinkers: A Chinese Community-Based Analysis

    Directory of Open Access Journals (Sweden)

    Shihui Fu

    2017-01-01

    Full Text Available Background. To investigate whether serum alanine aminotransferase (ALT levels within normal range were associated with augmentation index (AIx and cardiometabolic risk factors in nondrinkers and drinkers in Chinese community-dwelling population. Methods. There were 4165 participants with serum ALT levels within normal range. Results. Alcohol drinking was observed in 1173 participants (28.2%. In multivariate analysis, serum ALT levels of nondrinkers were independently associated with age, sex, body mass index (BMI, hypertension, diabetes mellitus, diastolic blood pressure, triglyceride, low-density lipoprotein-cholesterol (LDL-c, and AIx, while serum ALT levels of drinkers were independently associated with age, sex, BMI, triglyceride, and LDL-c (p<0.05 for all. Conclusions. Associations of serum ALT levels within normal range with age, sex, body height and weight, and blood lipid were simultaneously present in participants with and without alcohol drinking, while associations of serum ALT levels within normal range with AIx, blood pressure, and glucose were seen in nondrinkers rather than in drinkers. These findings not only provide the evidence that serum ALT levels, even within the normal range, have different associations with arteriosclerosis and cardiometabolic risk factors in nondrinkers and drinkers but also are helpful in understanding the underlying pathophysiologic mechanisms linking the hepatic function to arteriosclerosis and cardiometabolic risk factors.

  17. Factors influencing Dipylidium sp. infection in a free-ranging social carnivore, the spotted hyaena (Crocuta crocuta).

    Science.gov (United States)

    East, Marion L; Kurze, Christoph; Wilhelm, Kerstin; Benhaiem, Sarah; Hofer, Heribert

    2013-12-01

    We provide the first genetic sequence data for a Dipylidium species from a wild carnivore plus an analysis of the effects of ecological, demographic, physiological and behavioural factors on Dipylidium sp. infection prevalence in a social carnivore, the spotted hyaena (Crocuta crocuta), in the Serengeti National Park, Tanzania. Our sequence data from a mitochondrial gene fragment (1176 base pair long) had a similarity of between 99% and 89% to Dipylidium caninum. We determined infection prevalence in 146 faecal samples from 124 known animals in three social groups (termed clans) using molecular screening and Dipylidium proglottid presence. Our analysis revealed significantly higher infection prevalence in juveniles (55%) than adults (15.8%), indicating that predominantly juveniles maintained infection in clans. The likelihood of infection in juveniles significantly: (1) increased as the number of adults and older juveniles (>6 months) at communal dens increased, implying a positive relationship between this factor and the size of the intermediate host (probably a flea species) population at communal dens; (2) decreased as the number of younger juveniles (Dipylidium fecundity and hence decrease infection prevalence in the den flea population. Our study provides useful insights into Dipylidium epidemiology in a social carnivore population subject to large fluctuations in prey abundance.

  18. Factors influencing Dipylidium sp. infection in a free-ranging social carnivore, the spotted hyaena (Crocuta crocuta)☆

    Science.gov (United States)

    East, Marion L.; Kurze, Christoph; Wilhelm, Kerstin; Benhaiem, Sarah; Hofer, Heribert

    2013-01-01

    We provide the first genetic sequence data for a Dipylidium species from a wild carnivore plus an analysis of the effects of ecological, demographic, physiological and behavioural factors on Dipylidium sp. infection prevalence in a social carnivore, the spotted hyaena (Crocuta crocuta), in the Serengeti National Park, Tanzania. Our sequence data from a mitochondrial gene fragment (1176 base pair long) had a similarity of between 99% and 89% to Dipylidium caninum. We determined infection prevalence in 146 faecal samples from 124 known animals in three social groups (termed clans) using molecular screening and Dipylidium proglottid presence. Our analysis revealed significantly higher infection prevalence in juveniles (55%) than adults (15.8%), indicating that predominantly juveniles maintained infection in clans. The likelihood of infection in juveniles significantly: (1) increased as the number of adults and older juveniles (>6 months) at communal dens increased, implying a positive relationship between this factor and the size of the intermediate host (probably a flea species) population at communal dens; (2) decreased as the number of younger juveniles (Dipylidium fecundity and hence decrease infection prevalence in the den flea population. Our study provides useful insights into Dipylidium epidemiology in a social carnivore population subject to large fluctuations in prey abundance. PMID:24533344

  19. Epstein-Barr virus: general factors, virus-related diseases and measurement of viral load after transplant

    Directory of Open Access Journals (Sweden)

    Luciana Cristina Fagundes Gequelin

    2011-10-01

    Full Text Available The Epstein-Barr virus is responsible for infectious mononucleosis syndrome and is also closely associated to several types of cancer. The main complication involving Epstein-Barr virus infection, both in recipients of hematopoietic stem cells and solid organs, is post-transplant lymphoproliferative disease. The importance of this disease has increased interest in the development of laboratory tools to improve post-transplant monitoring and to detect the disease before clinical evolution. Viral load analysis for Epstein-Barr virus through real-time polymerase chain reaction is, at present, the best tool to measure viral load. However, there is not a consensus on which sample type is the best for the test and what is its predictive value for therapeutic interventions.

  20. Load-Dependent Emission Factors and Chemical Characteristics of IVOCs from a Medium-Duty Diesel Engine.

    Science.gov (United States)

    Cross, Eben S; Sappok, Alexander G; Wong, Victor W; Kroll, Jesse H

    2015-11-17

    A detailed understanding of the climate and air quality impacts of mobile-source emissions requires the characterization of intermediate-volatility organic compounds (IVOCs), relatively-low-vapor-pressure gas-phase species that may generate secondary organic aerosol with high yields. Due to challenges associated with IVOC detection and quantification, IVOC emissions remain poorly understood at present. Here, we describe measurements of the magnitude and composition of IVOC emissions from a medium-duty diesel engine. Measurements are made on an engine dynamometer and utilize a new mass-spectrometric instrument to characterize the load dependence of the emissions in near-real-time. Results from steady-state engine operation indicate that IVOC emissions are highly dependent on engine power, with highest emissions at engine idle and low-load operation (≤25% maximum rated power) with a chemical composition dominated by saturated hydrocarbon species. Results suggest that unburned fuel components are the dominant IVOCs emitted at low loads. As engine load increases, IVOC emissions decline rapidly and become increasingly characterized by unsaturated hydrocarbons and oxygenated organics, newly formed from incomplete combustion processes at elevated engine temperatures and pressures. Engine transients, including a cold-start ignition and engine acceleration, show IVOC emission profiles that are different in amount or composition compared to steady-state combustion, underscoring the utility of characterizing IVOC emissions with high time resolution across realistic engine operating conditions. We find possible evidence for IVOC losses on unheated dilution and sampling surfaces, which need to be carefully accounted for in IVOC emission studies.

  1. Impact of Bulldozer's Engine Load Factor on Fuel Consumption, CO2 Emission and Cost

    OpenAIRE

    V. Kecojevic; D. Komljenovic

    2011-01-01

    Problem statement: Bulldozers consume a large amount of diesel fuel and consequently produce a significant quantity of CO2. Environmental and economic cost issues related to fuel consumption and CO2 emission represent a substantial challenge to the mining industry. Approach: Impact of engine load conditions on fuel consumption and the subsequent CO2 emission and cost was analyzed for Caterpillar bulldozers. Results were compared with the data on bulldozers' fuel consu...

  2. Factors affecting individual foraging specialization and temporal diet stability across the range of a large "generalist" apex predator.

    Science.gov (United States)

    Rosenblatt, Adam E; Nifong, James C; Heithaus, Michael R; Mazzotti, Frank J; Cherkiss, Michael S; Jeffery, Brian M; Elsey, Ruth M; Decker, Rachel A; Silliman, Brian R; Guillette, Louis J; Lowers, Russell H; Larson, Justin C

    2015-05-01

    Individual niche specialization (INS) is increasingly recognized as an important component of ecological and evolutionary dynamics. However, most studies that have investigated INS have focused on the effects of niche width and inter- and intraspecific competition on INS in small-bodied species for short time periods, with less attention paid to INS in large-bodied reptilian predators and the effects of available prey types on INS. We investigated the prevalence, causes, and consequences of INS in foraging behaviors across different populations of American alligators (Alligator mississippiensis), the dominant aquatic apex predator across the southeast US, using stomach contents and stable isotopes. Gut contents revealed that, over the short term, although alligator populations occupied wide ranges of the INS spectrum, general patterns were apparent. Alligator populations inhabiting lakes exhibited lower INS than coastal populations, likely driven by variation in habitat type and available prey types. Stable isotopes revealed that over longer time spans alligators exhibited remarkably consistent use of variable mixtures of carbon pools (e.g., marine and freshwater food webs). We conclude that INS in large-bodied reptilian predator populations is likely affected by variation in available prey types and habitat heterogeneity, and that INS should be incorporated into management strategies to efficiently meet intended goals. Also, ecological models, which typically do not consider behavioral variability, should include INS to increase model realism and applicability.

  3. Factors affecting individual foraging specialization and temporal diet stability across the range of a large “generalist” apex predator

    Science.gov (United States)

    Rosenblatt, Adam E.; Nifong, James C.; Heithaus, Michael R.; Mazzotti, Frank J.; Cherkiss, Michael S.; Jeffery, Brian M.; Elsey, Ruth M.; Decker, Rachel A.; Silliman, Brian R.; Guillette, Louis J.; Lowers, Russell H.; Larson, Justin C.

    2015-01-01

    Individual niche specialization (INS) is increasingly recognized as an important component of ecological and evolutionary dynamics. However, most studies that have investigated INS have focused on the effects of niche width and inter- and intraspecific competition on INS in small-bodied species for short time periods, with less attention paid to INS in large-bodied reptilian predators and the effects of available prey types on INS. We investigated the prevalence, causes, and consequences of INS in foraging behaviors across different populations of American alligators (Alligator mississippiensis), the dominant aquatic apex predator across the southeast US, using stomach contents and stable isotopes. Gut contents revealed that, over the short term, although alligator populations occupied wide ranges of the INS spectrum, general patterns were apparent. Alligator populations inhabiting lakes exhibited lower INS than coastal populations, likely driven by variation in habitat type and available prey types. Stable isotopes revealed that over longer time spans alligators exhibited remarkably consistent use of variable mixtures of carbon pools (e.g., marine and freshwater food webs). We conclude that INS in large-bodied reptilian predator populations is likely affected by variation in available prey types and habitat heterogeneity, and that INS should be incorporated into management strategies to efficiently meet intended goals. Also, ecological models, which typically do not consider behavioral variability, should include INS to increase model realism and applicability.

  4. Nephrotic range proteinuria as a strong risk factor for rapid renal function decline during pre-dialysis phase in type 2 diabetic patients with severely impaired renal function.

    Science.gov (United States)

    Kitai, Yuichiro; Doi, Yohei; Osaki, Keisuke; Sugioka, Sayaka; Koshikawa, Masao; Sugawara, Akira

    2015-12-01

    Proteinuria is an established risk factor for progression of renal disease, including diabetic nephropathy. The predictive power of proteinuria, especially nephrotic range proteinuria, for progressive renal deterioration has been well demonstrated in diabetic patients with normal to relatively preserved renal function. However, little is known about the relationship between severity of proteinuria and renal outcome in pre-dialysis diabetic patients with severely impaired renal function. 125 incident dialysis patients with type 2 diabetes were identified. This study was aimed at retrospectively evaluating the impact of nephrotic range proteinuria (urinary protein-creatinine ratio above 3.5 g/gCr) on renal function decline during the 3 months just prior to dialysis initiation. In total, 103 patients (82.4 %) had nephrotic range proteinuria. The median rate of decline in estimated glomerular filtration rate (eGFR) in this study population was 0.98 (interquartile range 0.51-1.46) ml/min/1.73 m(2) per month. Compared to patients without nephrotic range proteinuria, patients with nephrotic range proteinuria showed significantly faster renal function decline (0.46 [0.24-1.25] versus 1.07 [0.64-1.54] ml/min/1.73 m(2) per month; p = 0.007). After adjusting for gender, age, systolic blood pressure, serum albumin, calcium-phosphorus product, hemoglobin A1c, and use of an angiotensin-converting enzyme inhibitor or an angiotensin II receptor blocker, patients with nephrotic range proteinuria showed a 3.89-fold (95 % CI 1.08-14.5) increased risk for rapid renal function decline defined as a decline in eGFR ≥0.5 ml/min/1.73 m(2) per month. Nephrotic range proteinuria is the predominant renal risk factor in type 2 diabetic patients with severely impaired renal function receiving pre-dialysis care.

  5. Myxoma virus M064 is a novel member of the poxvirus C7L superfamily of host range factors that controls the kinetics of myxomatosis in European rabbits.

    Science.gov (United States)

    Liu, Jia; Wennier, Sonia; Moussatche, Nissin; Reinhard, Mary; Condit, Richard; McFadden, Grant

    2012-05-01

    The myxoma virus (MYXV) carries three tandem C7L-like host range genes (M062R, M063R, and M064R). However, despite the fact that the sequences of these three genes are similar, they possess very distinctive functions in vivo. The role of M064 in MYXV pathogenesis was investigated and compared to the roles of M062 and M063. We report that M064 is a virulence factor that contributes to MYXV pathogenesis but lacks the host range properties associated with M062 and M063.

  6. Three Dimensional Parametric Analyses of Stress Concentration Factor and Its Mitigation in Isotropic and Orthotropic Plate with Central Circular Hole Under Axial In-Plane Loading

    Science.gov (United States)

    Nagpal, Shubhrata; Jain, Nitin Kumar; Sanyal, Shubhashis

    2016-01-01

    The problem of finding the stress concentration factor of a loaded rectangular plate has offered considerably analytical difficulty. The present work focused on understanding of behavior of isotropic and orthotropic plate subjected to static in-plane loading using finite element method. The complete plate model configuration has been analyzed using finite element method based software ANSYS. In the present work two parameters: thickness to width of plate (T/A) and diameter of hole to width of plate (D/A) have been varied for analysis of stress concentration factor (SCF) and its mitigation. Plates of five different materials have been considered for complete analysis to find out the sensitivity of stress concentration factor. The D/A ratio varied from 0.1 to 0.7 for analysis of SCF and varied from 0.1 to 0.5 for analyzing the mitigation of SCF. 0.01, 0.05 and 0.1 are considered as T/A ratio for all the cases. The results are presented in graphical form and discussed. The mitigation in SCF reported is very encouraging. The SCF is more sensitive to D/A ratio as compared to T/A.

  7. Prognostic factors for specific lower extremity and spinal musculoskeletal injuries identified through medical screening and training load monitoring in professional football (soccer): a systematic review

    Science.gov (United States)

    Sergeant, Jamie C; Parkes, Matthew J; Callaghan, Michael J

    2017-01-01

    Background Medical screening and load monitoring procedures are commonly used in professional football to assess factors perceived to be associated with injury. Objectives To identify prognostic factors (PFs) and models for lower extremity and spinal musculoskeletal injuries in professional/elite football players from medical screening and training load monitoring processes. Methods The MEDLINE, AMED, EMBASE, CINAHL Plus, SPORTDiscus and PubMed electronic bibliographic databases were searched (from inception to January 2017). Prospective and retrospective cohort studies of lower extremity and spinal musculoskeletal injury incidence in professional/elite football players aged between 16 and 40 years were included. The Quality in Prognostic Studies appraisal tool and the modified Grading of Recommendations Assessment, Development and Evaluation synthesis approach was used to assess the quality of the evidence. Results Fourteen studies were included. 16 specific lower extremity injury outcomes were identified. No spinal injury outcomes were identified. Meta-analysis was not possible due to heterogeneity and study quality. All evidence related to PFs and specific lower extremity injury outcomes was of very low to low quality. On the few occasions where multiple studies could be used to compare PFs and outcomes, only two factors demonstrated consensus. A history of previous hamstring injuries (HSI) and increasing age may be prognostic for future HSI in male players. Conclusions The assumed ability of medical screening tests to predict specific musculoskeletal injuries is not supported by the current evidence. Screening procedures should currently be considered as benchmarks of function or performance only. The prognostic value of load monitoring modalities is unknown. PMID:29177074

  8. Rating curve estimation of nutrient loads in Iowa rivers

    Science.gov (United States)

    Stenback, G.A.; Crumpton, W.G.; Schilling, K.E.; Helmers, M.J.

    2011-01-01

    Accurate estimation of nutrient loads in rivers and streams is critical for many applications including determination of sources of nutrient loads in watersheds, evaluating long-term trends in loads, and estimating loading to downstream waterbodies. Since in many cases nutrient concentrations are measured on a weekly or monthly frequency, there is a need to estimate concentration and loads during periods when no data is available. The objectives of this study were to: (i) document the performance of a multiple regression model to predict loads of nitrate and total phosphorus (TP) in Iowa rivers and streams; (ii) determine whether there is any systematic bias in the load prediction estimates for nitrate and TP; and (iii) evaluate streamflow and concentration factors that could affect the load prediction efficiency. A commonly cited rating curve regression is utilized to estimate riverine nitrate and TP loads for rivers in Iowa with watershed areas ranging from 17.4 to over 34,600km2. Forty-nine nitrate and 44 TP datasets each comprising 5-22years of approximately weekly to monthly concentrations were examined. Three nitrate data sets had sample collection frequencies averaging about three samples per week. The accuracy and precision of annual and long term riverine load prediction was assessed by direct comparison of rating curve load predictions with observed daily loads. Significant positive bias of annual and long term nitrate loads was detected. Long term rating curve nitrate load predictions exceeded observed loads by 25% or more at 33% of the 49 measurement sites. No bias was found for TP load prediction although 15% of the 44 cases either underestimated or overestimate observed long-term loads by more than 25%. The rating curve was found to poorly characterize nitrate and phosphorus variation in some rivers. ?? 2010 .

  9. Comparative limb bone loading in the humerus and femur of the tiger salamander: testing the 'mixed-chain' hypothesis for skeletal safety factors.

    Science.gov (United States)

    Kawano, Sandy M; Economy, D Ross; Kennedy, Marian S; Dean, Delphine; Blob, Richard W

    2016-02-01

    Locomotion imposes some of the highest loads upon the skeleton, and diverse bone designs have evolved to withstand these demands. Excessive loads can fatally injure organisms; however, bones have a margin of extra protection, called a 'safety factor' (SF), to accommodate loads that are higher than normal. The extent to which SFs might vary amongst an animal's limb bones is unclear. If the limbs are likened to a chain composed of bones as 'links', then similar SFs might be expected for all limb bones because failure of the system would be determined by the weakest link, and extra protection in other links could waste energetic resources. However, Alexander proposed that a 'mixed-chain' of SFs might be found amongst bones if: (1) their energetic costs differ, (2) some elements face variable demands, or (3) SFs are generally high. To test whether such conditions contribute to diversity in limb bone SFs, we compared the biomechanical properties and locomotor loading of the humerus and femur in the tiger salamander (Ambystoma tigrinum). Despite high SFs in salamanders and similar sizes of the humerus and femur that would suggest similar energetic costs, the humerus had lower bone stresses, higher mechanical hardness and larger SFs. SFs were greatest in the anatomical regions where yield stresses were highest in the humerus and lowest in the femur. Such intraspecific variation between and within bones may relate to their different biomechanical functions, providing insight into the emergence of novel locomotor capabilities during the invasion of land by tetrapods. © 2016. Published by The Company of Biologists Ltd.

  10. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years. 23 refs., 9 tabs

  11. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1986-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane earthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years

  12. Quantification of Epstein-Barr virus DNA load, interleukin-6, interleukin-10, transforming growth factor-β1 and stem cell factor in plasma of patients with nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Tan, Eng-lai; Selvaratnam, G; Kananathan, R; Sam, Choon-kook

    2006-01-01

    Nasopharyngeal carcinoma (NPC) is a common epithelial neoplasm among the Chinese populations in Southern China and South East Asia. Epstein-Barr virus (EBV) is known to be an important etiologic agent of NPC and the viral gene products are frequently detected in NPC tissues along with elevated antibody titres to the viral proteins (VCA and EA) in a majority of patients. Elevated plasma EBV DNA load is regarded as an important marker for the presence of the disease and for the monitoring of disease progression. However, other serum/plasma parameters such as the levels of certain interleukins and growth factors have also been implicated in NPC. The objectives of the present study are, 1) to investigate the correlations between plasma EBV DNA load and the levels of interleukin (IL)-6, IL-10, TGF-β1 and SCF (steel factor) and 2) to relate these parameters to the stages of NPC and the effect of treatment. A total of 78 untreated NPC patients were enrolled in this study. Of these, 51 were followed-up after treatment. The remaining patients had irregular or were lost to follow-up. Plasma EBV DNA was quantified using real-time quantitative PCR. The levels of plasma interleukins and growth factors were quantified using ELISA. A significant decrease in EBV DNA load was detected in plasma of untreated NPC patients (1669 ± 637 copies/mL; n = 51) following treatment (57 ± 37 copies/mL, p < 0.05); n = 51). Plasma EBV DNA load was shown to be a good prognosticator for disease progression and clinical outcome in five of the follow-up patients. A significant difference in IL-6 levels was noted between the untreated patients (164 ± 37 pg/mL; n = 51) and following treatment (58 ± 16 pg/mL, p < 0.05; n = 51). Positive correlations between EBV DNA load and IL-10 (r(49) = 0.535, p < 0.01), between IL6 and IL-10 (r(49) = 0.474, p < 0.01) and between TGF and SCF (r(49) = 0.464, p < 0.01) were observed in patients following treatment. None of the parameters tested including Ig

  13. Three Dimensional Parametric Analyses on Effect of Fibre Orientation for Stress Concentration Factor in Fibrous Composite Cantilever Plate with Central Circular Hole under Transverse Loading

    Directory of Open Access Journals (Sweden)

    Nitin Jain

    2012-10-01

    Full Text Available Normal 0 false false false EN-IN X-NONE X-NONE ABSTRACT: A number of analytical and numerical techniques are available for the two dimensional study of stress concentration around the hole(s in isotropic and composite plates subjected to in-plane or transverse loading conditions. The information on the techniques for three dimensional analyses of stress concentration factor (SCF around the hole in isotropic and composite plates subjected to transverse loading conditions is, however, limited. The present work emphasizes on the effect of fibre orientation (q on the stress concentration factor in fibrous composite plates with central circular hole under transverse static loading condition. The work is carried out for cantilever fibrous composite plates. The effects of thickness -to- width (T/A and diameter-to-width (D/A ratios upon SCF at different fibre orientation are studied. Plates of four different composite materials were considered for hole analysis in order to determine the sensitivity of SCF with elastic constants. Deflections in transverse direction were calculated and analysed. All results are presented in graphical form and discussed. The finite element formulation and its analysis were carried out using ANSYS package.ABSTRAK: Terdapat pelbagai teknik analitikal dan numerical untuk kajian tumpuan tegasan dua dimensi di sekeliling lubang-lubang dalam komposit isotropik dan plat pada satah atau keadaan bebanan melintang. Bagaimanapun, maklumat mengenai kaedah analisis tiga dimensi untuk faktor ketumpatan tegasan (SCF sekitar lubang dalam komposit isotropik dan plat pada keadaan bebanan melintang adalah terhad. Kertas ini menekankan kesan orientasi gentian (q pada faktor tumpuan tegasan dalam komposit plat bergentian dengan lubang berpusat di bawah keadaan bebanan melintang. Kajian ini dilkukan untuk cantilever plat komposit bergentian. Kesan ketebalan terhadap kelebaran plat (T/A dan diameter terhadap kelebaran komposit (D/A dengan SCF

  14. Determinación IN-SITU del factor de potencia y la eficiencia de motores asincrónicos a cargas parciales; Induction motor power factor and efficiency IN-SITU determination under partial loads.

    Directory of Open Access Journals (Sweden)

    Percy Rafael Viego Felipe

    2015-04-01

    Full Text Available Los motores asincrónicos trifásicos no siempre operan a plena carga y por lo tanto, el factor de potencia y la eficiencia se ven afectados. Determinar estos valores a diferentes cargas, es la base para programas ahorro en la industria y los servicios. En este trabajo se presentan procedimientos para la estimación del factor de potencia y la eficiencia a cargas parciales, con una precisión acorde a los propósitos ingenieriles, baja invasividad y sin implicar para el usuario complejidades de equipamiento o de adquisición y procesamiento de datos. Se ofrecen distintas variantes para la estimación del factor de potencia y la eficiencia, según los datos con que se cuente. Se comparan los resultados de los métodos propuestos con la información de catálogos comerciales. Se realiza un análisis con motores de distinta potencia y velocidad, que demuestra que se logra buena precisión para los propósitos señalados. Three phase induction motors are rarely operating at full load and, in consequence, power factor and efficiency are affected. Determining these values for different partial loads is needed for energy saving programs in industrial and service enterprises. In this work, procedures are given for power factor and efficiency estimation at different loads. These procedures are low or not-invasive, have a good precision for engineering purposes, and do not require neither complex equipment nor complicated acquisition and processing data systems Different ways for estimating the before mentioned parameters, depending on the known data, are given. The results of the proposed procedures are compared with those of manufacturer catalogs. A comparative analysis considering motors of different output power and speed is done, and it shows that the results are enough accurate for the established purposes.

  15. Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis

    Directory of Open Access Journals (Sweden)

    Siavash Sadeghi

    2017-08-01

    Full Text Available The use of Lightweight Steel Frames (LSF has grown considerably in recent years all over the world due to its unique advantages such as being cost-effective and light-weight, easy and quick installment. Another application is to use them in order to increase the number of new floors on the existing buildings. But since the behavior of the combined structure is not clear, there is no possibility of increasing new floors with Lightweight Steel Frames. Therefore, through selecting and modeling three buildings of three, five and seven floors with steel moment frames in SAP2000 software and adding one or two new floors using Lightweight Steel Frames (LSF and conducting a non-linear static analysis with three different lateral load pattern, we dealt with the seismic behavior and determined the behavior coefficient of each of the combined structures. The results indicated that the use of cold-formed structures in order to add story do not have a significant impact on R-factor. In addition, R-factor depends on the type of the side loading pattern.

  16. Load and resistance factor design calibration to determine a resistance factor for the modification of the Kansas Department of Transportation-Engineering News Record formula.

    Science.gov (United States)

    2014-02-01

    This report contains the results of a study describing the development of resistance factors for use : with the Kansas Department of Transportation (KDOT) Engineering News Record (ENR) formula for driven : piles. KDOT has verified driven pile resista...

  17. Mixed-mode stress intensity factors for kink cracks with finite kink length loaded in tension and bending: application to dentin and enamel.

    Science.gov (United States)

    Bechtle, Sabine; Fett, Theo; Rizzi, Gabriele; Habelitz, Stefan; Schneider, Gerold A

    2010-05-01

    Fracture toughness resistance curves describe a material's resistance against crack propagation. These curves are often used to characterize biomaterials like bone, nacre or dentin as these materials commonly exhibit a pronounced increase in fracture toughness with crack extension due to co-acting mechanisms such as crack bridging, crack deflection and microcracking. The knowledge of appropriate stress intensity factors which depend on the sample and crack geometry is essential for determining these curves. For the dental biomaterials enamel and dentin it was observed that, under bending and tensile loading, crack propagation occurs under certain constant angles to the initial notch direction during testing procedures used for fracture resistance curve determination. For this special crack geometry (a kink crack of finite length in a finite body) appropriate geometric function solutions are missing. Hence, we present in this study new mixed-mode stress intensity factors for kink cracks with finite kink length within samples of finite dimensions for two loading cases (tension and bending) which were derived from a combination of mixed-mode stress intensity factors of kink cracks with infinitely small kinks and of slant cracks. These results were further applied to determine the fracture resistance curves of enamel and dentin by testing single edge notched bending (SENB) specimens. It was found that kink cracks with finite kink length exhibit identical stress fields to slant cracks as soon as the kink length exceeds 0.15 times the initial straight crack or notch length. The use of stress intensity factor solutions for infinitely small kink cracks for the determination of dentin fracture resistance curves (as was done by other researchers) leads to an overestimation of dentin's fracture resistance of up to 30%. Copyright 2010 Elsevier Ltd. All rights reserved.

  18. Applying Cognitive Load Theory Principles to Library Instructional Guidance

    Science.gov (United States)

    Pickens, Kathleen E.

    2017-01-01

    If the goal of library instructional guidance is to provide students with the knowledge needed to acquire new skills in order to accomplish their learning objectives, then it is prudent to consider factors that impact learning. Cognitive load theory addresses several of these factors and is applicable to a wide-range of instructional devices used…

  19. Monte Carlo Method to Study Properties of Acceleration Factor Estimation Based on the Test Results with Varying Load

    Directory of Open Access Journals (Sweden)

    N. D. Tiannikova

    2014-01-01

    Full Text Available G.D. Kartashov has developed a technique to determine the rapid testing results scaling functions to the normal mode. Its feature is preliminary tests of products of one sample including tests using the alternating modes. Standard procedure of preliminary tests (researches is as follows: n groups of products with m elements in each start being tested in normal mode and, after a failure of one of products in the group, the remained products are tested in accelerated mode. In addition to tests in alternating mode, tests in constantly normal mode are conducted as well. The acceleration factor of rapid tests for this type of products, identical to any lots is determined using such testing results of products from the same lot. A drawback of this technique is that tests are to be conducted in alternating mode till the failure of all products. That is not always is possible. To avoid this shortcoming, the Renyi criterion is offered. It allows us to determine scaling functions using the right-censored data thus giving the opportunity to stop testing prior to all failures of products.In this work a statistical modeling of the acceleration factor estimation owing to Renyi statistics minimization is implemented by the Monte-Carlo method. Results of modeling show that the acceleration factor estimation obtained through Renyi statistics minimization is conceivable for rather large n . But for small sample volumes some systematic bias of acceleration factor estimation, which decreases with growth n is observed for both distributions (exponential and Veybull's distributions. Therefore the paper also presents calculation results of correction factors for a case of exponential distribution and Veybull's distribution.

  20. Characteristics and reference ranges of Insulin-Like Growth Factor-I measured with a commercially available immunoassay in 724 healthy adult Caucasians

    DEFF Research Database (Denmark)

    Andreassen, Mikkel; Nielsen, Kaspar; Raymond, Ilan

    2009-01-01

    BACKGROUND AND OBJECTIVE: Measurements of Insulin-Like Growth Factor-I (IGF-I) play a pivotal role in the evaluation of the growth hormone-IGF-I axis. Due to assay variation IGF-I reference ranges are assay specific. We provide serum IGF-I reference ranges for adult men and women obtained...... by a commercially available assay. METHOD: IGF-I was measured by an enzyme-linked immunosorbent assay (R&D Systems). Assay precision was evaluated in low, medium and high IGF-I pools and in single samples from outpatients. The reference ranges were obtained in 724 healthy Caucasians, mean age 48 years (range 19....../mL (mean 1 SD) were 5, 3 and 3%. Interassays CVs for the low, medium and high pool varied between 7-10, 5-7, and 6-9%. Reproducibility between 4 different lots showed a intraclass CV of 0.99 (95%CI 0.98-0.96). Logarithmically transformed IGF-I levels were linearly associated with age with a 13% reduction...

  1. Elevated Norepinephrine may be a Unifying Etiological Factor in the Abuse of a Broad Range of Substances: Alcohol, Nicotine, Marijuana, Heroin, Cocaine, and Caffeine

    Directory of Open Access Journals (Sweden)

    Paul J. Fitzgerald

    2013-01-01

    Full Text Available A wide range of commonly abused drugs have effects on the noradrenergic neurotransmitter system, including alterations during acute intoxication and chronic use of these drugs. It is not established, however, that individual differences in noradrenergic signaling, which may be present prior to use of drugs, predispose certain persons to substance abuse. This paper puts forth the novel hypothesis that elevated noradrenergic signaling, which may be raised largely due to genetics but also due to environmental factors, is an etiological factor in the abuse of a wide range of substances, including alcohol, nicotine, marijuana, heroin, cocaine, and caffeine. Data are reviewed for each of these drugs comprising their interaction with norepinephrine during acute intoxication, long-term use, subsequent withdrawal, and stress-induced relapse. In general, the data suggest that these drugs acutely boost noradrenergic signaling, whereas long-term use also affects this neurotransmitter system, possibly suppressing it. During acute withdrawal after chronic drug use, noradrenergic signaling tends to be elevated, consistent with the observation that norepinephrine lowering drugs such as clonidine reduce withdrawal symptoms. Since psychological stress can promote relapse of drug seeking in susceptible individuals and stress produces elevated norepinephrine release, this suggests that these drugs may be suppressing noradrenergic signaling during chronic use or instead elevating it only in reward circuits of the brain. If elevated noradrenergic signaling is an etiological factor in the abuse of a broad range of substances, then chronic use of pharmacological agents that reduce noradrenergic signaling, such as clonidine, guanfacine, lofexidine, propranolol, or prazosin, may help prevent or treat drug abuse in general.

  2. Elevated Norepinephrine may be a Unifying Etiological Factor in the Abuse of a Broad Range of Substances: Alcohol, Nicotine, Marijuana, Heroin, Cocaine, and Caffeine.

    Science.gov (United States)

    Fitzgerald, Paul J

    2013-10-13

    A wide range of commonly abused drugs have effects on the noradrenergic neurotransmitter system, including alterations during acute intoxication and chronic use of these drugs. It is not established, however, that individual differences in noradrenergic signaling, which may be present prior to use of drugs, predispose certain persons to substance abuse. This paper puts forth the novel hypothesis that elevated noradrenergic signaling, which may be raised largely due to genetics but also due to environmental factors, is an etiological factor in the abuse of a wide range of substances, including alcohol, nicotine, marijuana, heroin, cocaine, and caffeine. Data are reviewed for each of these drugs comprising their interaction with norepinephrine during acute intoxication, long-term use, subsequent withdrawal, and stress-induced relapse. In general, the data suggest that these drugs acutely boost noradrenergic signaling, whereas long-term use also affects this neurotransmitter system, possibly suppressing it. During acute withdrawal after chronic drug use, noradrenergic signaling tends to be elevated, consistent with the observation that norepinephrine lowering drugs such as clonidine reduce withdrawal symptoms. Since psychological stress can promote relapse of drug seeking in susceptible individuals and stress produces elevated norepinephrine release, this suggests that these drugs may be suppressing noradrenergic signaling during chronic use or instead elevating it only in reward circuits of the brain. If elevated noradrenergic signaling is an etiological factor in the abuse of a broad range of substances, then chronic use of pharmacological agents that reduce noradrenergic signaling, such as clonidine, guanfacine, lofexidine, propranolol, or prazosin, may help prevent or treat drug abuse in general.

  3. Linking long-range weather forecasts and heat consumption as a determining factor when buying fuel chips for town heating plants

    International Nuclear Information System (INIS)

    Rolev, A.-M.

    1991-12-01

    The aim of this study is to test whether long-range weather forecasts from the meteorological services can be used as a determining factor when buying fuel chips. In the study the fuel consumption of heating plants and the factors determining the monthly consumption are mentioned. Degree-day statistics in Denmark for the last 30 years are explained as well as the difficulties in conjunction with the prediction of long-range weather conditions. This study compares degree days in 1989-1990 month by month with the actual and theoretic chip consumption in three different heating plants the same year. The theoretic chip consumption is calculated on the basis of degree days in a ''standard year'' and the annual chip consumption of the heating plant, among other things. Furthermore, on the basis of degree-day statistics the report makes it possible to estimate the monthly chip consumption of a heating plant in a ''standard year'', in an extremely cold year (maximum degree days), and in an extremely warm year (minimum degree days). However, not everything can be predicted, and it is not yet possible to predict reliable weather forecasts for more than 5 days ahead. The study concludes that long-range weather forecasts cannot be used as a determining factor when buying fuel chips for heating plants. When buying fuel chips one must still use statistics and degree days, supplimented by figures based on experience from actual chip consumption in the individual heating plant. These figures take into consideration the different types of heating plants, as well as heat supply, chip-supplier, storing facilities, other fuels, etc. (au)

  4. Independent predictive factors for significant liver histological changes in patients with HBeAg-positive high-viral-load chronic HBV infection and a normal alanine aminotransferase level

    Directory of Open Access Journals (Sweden)

    LI Qiang

    2016-07-01

    Full Text Available Objective To investigate the independent predictive factors for significant liver histological changes (SLHCs in patients with HBeAg-positive high-viral-load chronic hepatitis B virus (HBV infection and a normal alanine aminotransferase (ALT level. MethodsA retrospective analysis was performed on the clinical data of 116 previously untreated patients with HBeAg-positive high-viral-load (HBV DNA≥105 copies/ml chronic HBV infection and a normal ALT level (<50 U/L who were hospitalized in Shanghai Public Health Clinical Center Affiliated to Fudan University from June 2013 to August 2015. The definition of SLHCs was inflammation ≥G2 and/or fibrosis≥S2. The t-test or Mann-Whitney U rank sum test was used for comparison of continuous data between groups, and the chi-square test was used for comparison of categorical data between groups. Univariate and multivariate regression analyses were used to determine independent predictive factors for SLHCs. ResultsOf all the 116 patients, 47(40.5% had SLHCs. The multivariate analysis showed that age (OR=2.828, P<0.05, ALT (OR=1.011, P<0.05, and gamma-glutamyl transpeptidase (GGT (OR=1.089, P<0.05 were independent predictors for SLHCs in patients with HBeAg-positive high-viral-load chronic HBV infection and a normal ALT level. The patients aged ≤30 years had a significantly lower incidence rate of SLHCs than those aged>30 years (21.6% vs 49.4%, χ2=6.42, P=0.015, the patients with ALT ≤30 U/L had a significantly lower incidence rate of SLHCs than those with 30 U/L<ALT≤50 U/L (17.6% vs 50.0%, χ2=19.86, P<0.001, and the patients with GGT≤40 U/L had a significantly lower incidence rate of SLHCs than those with GGT>40 U/L (28.8% vs 66.7%, χ2=28.63, P<0.001. ConclusionIn patients with HBeAg-positive high-viral-load chronic HBV infection and a normal ALT level, those with an age of>30 years, ALT>30 U/L, and GGT>40 U/L tend to develop SLHCs and need liver biopsy.

  5. Cumulative socioeconomic status risk, allostatic load, and adjustment: a prospective latent profile analysis with contextual and genetic protective factors.

    Science.gov (United States)

    Brody, Gene H; Yu, Tianyi; Chen, Yi-fu; Kogan, Steven M; Evans, Gary W; Beach, Steven R H; Windle, Michael; Simons, Ronald L; Gerrard, Meg; Gibbons, Frederick X; Philibert, Robert A

    2013-05-01

    The health disparities literature has identified a common pattern among middle-aged African Americans that includes high rates of chronic disease along with low rates of psychiatric disorders despite exposure to high levels of cumulative socioeconomic status (SES) risk. The current study was designed to test hypotheses about the developmental precursors to this pattern. Hypotheses were tested with a representative sample of 443 African American youths living in the rural South. Cumulative SES risk and protective processes were assessed at ages 11-13 years; psychological adjustment was assessed at ages 14-18 years; genotyping at the 5-HTTLPR was conducted at age 16 years; and allostatic load (AL) was assessed at age 19 years. A latent profile analysis identified 5 profiles that evinced distinct patterns of SES risk, AL, and psychological adjustment, with 2 relatively large profiles designated as focal profiles: a physical health vulnerability profile characterized by high SES risk/high AL/low adjustment problems, and a resilient profile characterized by high SES risk/low AL/low adjustment problems. The physical health vulnerability profile mirrored the pattern found in the adult health disparities literature. Multinomial logistic regression analyses indicated that carrying an s allele at the 5-HTTLPR and receiving less peer support distinguished the physical health vulnerability profile from the resilient profile. Protective parenting and planful self-regulation distinguished both focal profiles from the other 3 profiles. The results suggest the public health importance of preventive interventions that enhance coping and reduce the effects of stress across childhood and adolescence.

  6. A closed-form formulation for the build-up factor and absorbed energy for photons and electrons in the Compton energy range in Cartesian geometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Volnei; Vilhena, Marco Tullio, E-mail: borges@ufrgs.b, E-mail: vilhena@pq.cnpq.b [Universidade Federal do Rio Grande do Sul (PROMEC/UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica; Fernandes, Julio Cesar Lombaldo, E-mail: julio.lombaldo@ufrgs.b [Universidade Federal do Rio Grande do Sul (DMPA/UFRGS), Porto Alegre, RS (Brazil). Dept. de Matematica Pura e Aplicada. Programa de Pos Graduacao em Matematica Aplicada

    2011-07-01

    In this work, we report on a closed-form formulation for the build-up factor and absorbed energy, in one and two dimensional Cartesian geometry for photons and electrons, in the Compton energy range. For the one-dimensional case we use the LTS{sub N} method, assuming the Klein-Nishina scattering kernel for the determination of the angular radiation intensity for photons. We apply the two-dimensional LTS{sub N} nodal solution for the averaged angular radiation evaluation for the two-dimensional case, using the Klein-Nishina kernel for photons and the Compton kernel for electrons. From the angular radiation intensity we construct a closed-form solution for the build-up factor and evaluate the absorbed energy. We present numerical simulations and comparisons against results from the literature. (author)

  7. A closed-form formulation for the build-up factor and absorbed energy for photons and electrons in the Compton energy range in Cartesian geometry

    International Nuclear Information System (INIS)

    Borges, Volnei; Vilhena, Marco Tullio; Fernandes, Julio Cesar Lombaldo

    2011-01-01

    In this work, we report on a closed-form formulation for the build-up factor and absorbed energy, in one and two dimensional Cartesian geometry for photons and electrons, in the Compton energy range. For the one-dimensional case we use the LTS N method, assuming the Klein-Nishina scattering kernel for the determination of the angular radiation intensity for photons. We apply the two-dimensional LTS N nodal solution for the averaged angular radiation evaluation for the two-dimensional case, using the Klein-Nishina kernel for photons and the Compton kernel for electrons. From the angular radiation intensity we construct a closed-form solution for the build-up factor and evaluate the absorbed energy. We present numerical simulations and comparisons against results from the literature. (author)

  8. Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors.

    Science.gov (United States)

    Gutiérrez, Sergio; Comiskey, Charles A; Luo, Zong-Ping; Pupello, Derek R; Frankle, Mark A

    2008-12-01

    Evaluations of functional outcomes of reverse shoulder arthroplasty have revealed variable improvements in the range of motion and high rates of scapular notching. The purpose of this study was to systematically examine the impact of surgical factors (location of the glenosphere on the glenoid and tilt angle of the glenosphere on the glenoid) and implant-related factors (implant size, center-of-rotation offset, and humeral neck-shaft angle) on impingement-free abduction motion. A computer model was developed to virtually simulate abduction/adduction motion and its dependence on five surgical and implant-related factors. Three conditions were tested for each factor, resulting in a total of 243 simulated combinations. The overall motion was determined from 0 degrees of abduction until maximum abduction, which would be limited by impingement of the humerosocket on the scapula. In those combinations in which 0 degrees of abduction could not be achieved, the adduction deficit was recorded. The largest average increase in the range of impingement-free abduction motion resulted from a more lateral center-of-rotation offset: the average increase was 31.9 degrees with a change in the center-of-rotation offset from 0 to 10 mm, and this change resulted in an increase in abduction motion in eighty of the eighty-one combinations. The position of the glenosphere on the glenoid was associated with the second largest average increase in abduction motion (28.1 degrees when the glenosphere position was changed from superior to inferior, with the change resulting in an increase in seventy-one of the eighty-one combinations). These factors were followed by glenosphere tilt, humeral neck-shaft angle, and prosthetic size in terms of their effects on abduction motion. The largest effect in terms of avoiding an adduction deficit was provided by a humeral neck-shaft angle of 130 degrees (the deficit was avoided in forty-nine of the eighty-one combinations in which this angle was used

  9. Identification of the Uncertainties for the Calibration of the Partial Safety Factors for Load in Tidal Turbines

    Directory of Open Access Journals (Sweden)

    Gaizka Zarraonandia Simeón

    2016-03-01

    Full Text Available Tidal energy is nowadays one of the fastest growing types of marine renewable energy. In particular, Horizontal Axis Tidal Turbines (HATTs are the most advanced designs and the most appropriate for standardization. This paper presents a review of actual design criteria focusing on the identification of the uncertainties that technology developers need to address during the design process. Key environmental parameters like turbine inflow conditions or predictions of extreme values are still grey areas due to the lack of site measurements and the uncertainty in metocean model predictions. A comparison of turbulence intensity characterization using different tools and at different points in time shows the uncertainty in the prediction of this parameter. Numerical models of HATTs are still quite uncertain, often dependent on experience of the people running them. In the reliability-based calibration of partial safety factors, the uncertainties need to be reflected on the limit state formulation. This paper analyses the different types of uncertainties present in the limit state equation. These uncertainties are assessed in terms of stochastic variables in the limit state equation. In some cases, advantage can be taken from the experience from offshore wind and oil and gas industries. Tidal turbines have a mixture of the uncertainties present in both industries with regard to partial safety factor calibration.

  10. Simplified analysis of laterally loaded pile groups

    Directory of Open Access Journals (Sweden)

    F.M. Abdrabbo

    2012-06-01

    Full Text Available The response of laterally loaded pile groups is a complicated soil–structure interaction problem. Although fairly reliable methods are developed to predicate the lateral behavior of single piles, the lateral response of pile groups has attracted less attention due to the required high cost and complication implication. This study presents a simplified method to analyze laterally loaded pile groups. The proposed method implements p-multiplier factors in combination with the horizontal modulus of subgrade reaction. Shadowing effects in closely spaced piles in a group were taken into consideration. It is proven that laterally loaded piles embedded in sand can be analyzed within the working load range assuming a linear relationship between lateral load and lateral displacement. The proposed method estimates the distribution of lateral loads among piles in a pile group and predicts the safe design lateral load of a pile group. The benefit of the proposed method is in its simplicity for the preliminary design stage with a little computational effort.

  11. Surface modification of vascular endothelial growth factor-loaded silk fibroin to improve biological performance of ultra-high-molecular-weight polyethylene via promoting angiogenesis

    Directory of Open Access Journals (Sweden)

    Ai C

    2017-10-01

    Full Text Available Chengchong Ai, Dandan Sheng, Jun Chen, Jiangyu Cai, Siheng Wang, Jia Jiang, Shiyi Chen Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, People’s Republic of China Abstract: Ultra-high-molecular-weight polyethylene (UHMWPE has been applied in orthopedics, as the materials of joint prosthesis, artificial ligaments, and sutures due to its advantages such as high tensile strength, good wear resistance, and chemical stability. However, postoperative osteolysis induced by UHMWPE wear particles and poor bone–implant healing interface due to scarcity of osseointegration is a significant problem and should be solved imperatively. In order to enhance its affinity to bone tissue, vascular endothelial growth factor (VEGF was loaded on the surface of materials, the loading was performed by silk fibroin (SF coating to achieve a controlled-release delivery. Several techniques including field emission scanning electron microscopy (FESEM and attenuated total reflectance (ATR-Fourier transform infrared (FTIR and water contact angle measurement were used to validate the effectiveness of introduction of SF/VEGF. The result of ELISA demonstrated that the release of VEGF was well maintained up to 4 weeks. The modified UHMWPE was evaluated by both in vitro and in vivo experiments. According to the results of FESEM and cell counting kit-8 (CCK-8 assay, bone marrow mesenchymal stem cells cultured on the UHMWPE coated with SF/VEGF and SF exhibited a better proliferation performance than that of the pristine UHMWPE. The model rabbit of anterior cruciate ligament reconstruction was used to observe the graft–bone healing process in vivo. The results of histological evaluation, microcomputed tomography (micro-CT analysis, and biomechanical tests performed at 6 and 12 weeks after surgery demonstrated that graft–bone healing could be significantly improved due to the effect of VEGF on angiogenesis, which was loaded on the surface by SF

  12. Interaction of Mechanical Load with Growth Hormone (GH) and Insulin-Like Growth Factor I (IGF-I) on Slow-Twitch Skeletal Muscle and Bone

    Science.gov (United States)

    Linderman, Jon K.; Gosselink, Kristin L.; Wang, Tommy J.; Mukku, Venkat R.; Grindeland, Richard E.

    1994-01-01

    Exogenous humoral growth factors, combined with increased mechanical loading, reportedly induce hypertrophy of fast-, but not slow-twitch skeletal muscles, and have little effect in attenuating atrophy of slow-twitch muscle associated with exposure to microgravity in animals with intact neuroendocrine systems. These observations suggest that anabolic adjuvants and muscle tension do not interact to stimulate growth or maintenance of slow-twitch skeletal muscle. The purpose of the present study was to determine whether a chronic increase in mechanical loading (synergistic ablation) or hindlimb unweighting (hindlimb suspension) interact with exogenous GH and IGF-I (Genentech, So San Francisco, CA) in the slow-twitch soleus muscles of female rats (approx. 250 g). Bilateral ablation of the plantaris and gastrocnemius muscles induced 38% and 40% increases in the absolute (mg/pair) and relative (mg/100 g body weight) weights of the soleus, respectively (p less than or = 0.05), in ambulatory rats. GH and IGF-I interacted with chronic loading to increase absolute soleus mass an additional 20% (p less than or = 0.05), and mixed and myofibrillar protein contents an additional 12% and 7%, respectively (NS). In contrast, hindlimb suspension (HLS) resulted in 20% and 18% decreases in the absolute and relative weights of the soleus, respectively (p less than or = 0.05); GH and IGF-I did not spare loss of soleus mass or protein content in HLS rats. HLS decreased tibial plate thickness approx. 11% (p less than or = 0.05), but not weights of the tibia or femus. GH and IGF-I increased tibial plate thickness approx. 30% (p less than or = 0.05), in ambulatory and HLS rats, and increased femur and tibial weights 12% (p less than or = 0.05) and 8% (NS), respectively, in ambulatory rats, but had no effect in HLS rats. Results of the present investigation suggest that GH and IGF-I can stimulate hypertrophy of slow-twitch skeletal muscle when chronically overloaded, but can also stimulate

  13. Ultrasound-targeted stromal cell-derived factor-1-loaded microbubble destruction promotes mesenchymal stem cell homing to kidneys in diabetic nephropathy rats

    Directory of Open Access Journals (Sweden)

    Wu S

    2014-12-01

    Full Text Available Shengzheng Wu,1 Lu Li,1 Gong Wang,1 Weiwei Shen,2 Yali Xu,1 Zheng Liu,1 Zhongxiong Zhuo,1 Hongmei Xia,1 Yunhua Gao,1 Kaibin Tan1 1Department of Ultrasound, 2Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, People’s Republic of China Abstract: Mesenchymal stem cell (MSC therapy has been considered a promising strategy to cure diabetic nephropathy (DN. However, insufficient MSCs can settle in injured kidneys, which constitute one of the major barriers to the effective implementation of MSC therapy. Stromal cell-derived factor-1 (SDF-1 plays a vital role in MSC migration and involves activation, mobilization, homing, and retention, which are presumably related to the poor homing in DN therapy. Ultrasound-targeted microbubble destruction has become one of the most promising strategies for the targeted delivery of drugs and genes. To improve MSC homing to DN kidneys, we present a strategy to increase SDF-1 via ultrasound-targeted microbubble destruction. In this study, we developed SDF-1-loaded microbubbles (MBSDF-1 via covalent conjugation. The characterization and bioactivity of MBSDF-1 were assessed in vitro. Target release in the targeted kidneys was triggered with diagnostic ultrasound in combination with MBSDF-1. The related bioeffects were also elucidated. Early DN was induced in rats with streptozotocin. Green fluorescent protein-labeled MSCs were transplanted intravenously following the target release of SDF-1 in the kidneys of normal and DN rats. The homing efficacy was assessed by detecting the implanted exogenous MSCs at 24 hours. The in vitro results showed an impressive SDF-1 loading efficacy of 79% and a loading content of 15.8 µg/mL. MBSDF-1 remained bioactive as a chemoattractant. In the in vivo study, SDF-1 was successfully released in the targeted kidneys. The homing efficacy of MSCs to DN kidneys after the target release of SDF-1 was remarkably ameliorated at 24 hours compared with

  14. Underwater Ranging

    OpenAIRE

    S. P. Gaba

    1984-01-01

    The paper deals with underwater laser ranging system, its principle of operation and maximum depth capability. The sources of external noise and methods to improve signal-to-noise ratio are also discussed.

  15. Load compensation for single phase system using series active filter ...

    African Journals Online (AJOL)

    Load compensation for single phase system using series active filter. ... KK Mishra, R Gupta ... load varies from time to time, the non linear load ranging from voltage source type harmonic load (VSHL) dominant to current source type harmonic ...

  16. Suitability of a combined steam gas power plant in connection with a plant for production of gaseous fuel with a low heating value for the generation of electric power in the middle range of the load characteristic

    International Nuclear Information System (INIS)

    Alich, J.A. Jr.; Dickenson, R.L.; Korens, N.

    1975-01-01

    The report deals with the summary of the basic considerations concerning the gasification of oil and coal to produce electrical power. The application requirements in the middle region of the load diagram are discussed. A survey on the suitability of corresponding gasification equipment as well as methods for such a production of energy are described. The profitableness of an electroenergy-producing medium in the combined cycle with a gas having low heating value for the operation in this load diagram region is compared with other methods. (orig./LH) [de

  17. The role of the demand-duration curve in the evaluation of power station installation policies. Remarks on its effects on stations' utilization, generating capacity, load factor history and consumptions

    International Nuclear Information System (INIS)

    Graziani, G.; Maineri, M.; Zanantoni, C.

    1976-12-01

    The role of the load-duration curve in determining the installation policy for an electric power system, is examined. The effect of the priority order for the allocation of the power stations in the load-diagram is also discussed: in the model used here (program TOTEM) this priority is given as a function of type and age of the station. The significance of the load factor history for a power station as a function of its age is also discussed. It is suggested that such a curve be deduced as a result of strategy calculations made with TOTEM rather than assumping it as input data

  18. Factors affecting date of implantation, parturition, and den entry estimated from activity and body temperature in free-ranging brown bears.

    Science.gov (United States)

    Friebe, Andrea; Evans, Alina L; Arnemo, Jon M; Blanc, Stéphane; Brunberg, Sven; Fleissner, Günther; Swenson, Jon E; Zedrosser, Andreas

    2014-01-01

    Knowledge of factors influencing the timing of reproduction is important for animal conservation and management. Brown bears (Ursus arctos) are able to vary the birth date of their cubs in response to their fat stores, but little information is available about the timing of implantation and parturition in free-ranging brown bears. Body temperature and activity of pregnant brown bears is higher during the gestation period than during the rest of hibernation and drops at parturition. We compared mean daily body temperature and activity levels of pregnant and nonpregnant females during preimplantation, gestation, and lactation. Additionally we tested whether age, litter size, primiparity, environmental conditions, and the start of hibernation influence the timing of parturition. The mean date of implantation was 1 December (SD = 12), the mean date of parturition was 26 January (SD = 12), and the mean duration of the gestation period was 56 days (SD = 2). The body temperature of pregnant females was higher during the gestation and lactation periods than that of nonpregnant bears. The body temperature of pregnant females decreased during the gestation period. Activity recordings were also used to determine the date of parturition. The parturition dates calculated with activity and body temperature data did not differ significantly and were the same in 50% of the females. Older females started hibernation earlier. The start of hibernation was earlier during years with favorable environmental conditions. Dates of parturition were later during years with good environmental conditions which was unexpected. We suggest that free-ranging pregnant brown bears in areas with high levels of human activities at the beginning of the denning period, as in our study area, might prioritize investing energy in early denning than in early parturition during years with favorable environmental conditions, as a strategy to prevent disturbances caused by human.

  19. How Much Does it Cost to Expand a Protected Area System? Some Critical Determining Factors and Ranges of Costs for Queensland

    Science.gov (United States)

    Adams, Vanessa M.; Segan, Daniel B.; Pressey, Robert L.

    2011-01-01

    Many governments have recently gone on record promising large-scale expansions of protected areas to meet global commitments such as the Convention on Biological Diversity. As systems of protected areas are expanded to be more comprehensive, they are more likely to be implemented if planners have realistic budget estimates so that appropriate funding can be requested. Estimating financial budgets a priori must acknowledge the inherent uncertainties and assumptions associated with key parameters, so planners should recognize these uncertainties by estimating ranges of potential costs. We explore the challenge of budgeting a priori for protected area expansion in the face of uncertainty, specifically considering the future expansion of protected areas in Queensland, Australia. The government has committed to adding ∼12 million ha to the reserve system, bringing the total area protected to 20 million ha by 2020. We used Marxan to estimate the costs of potential reserve designs with data on actual land value, market value, transaction costs, and land tenure. With scenarios, we explored three sources of budget variability: size of biodiversity objectives; subdivision of properties; and legal acquisition routes varying with tenure. Depending on the assumptions made, our budget estimates ranged from $214 million to $2.9 billion. Estimates were most sensitive to assumptions made about legal acquisition routes for leasehold land. Unexpected costs (costs encountered by planners when real-world costs deviate from assumed costs) responded non-linearly to inability to subdivide and percentage purchase of private land. A financially conservative approach - one that safeguards against large cost increases while allowing for potential financial windfalls - would involve less optimistic assumptions about acquisition and subdivision to allow Marxan to avoid expensive properties where possible while meeting conservation objectives. We demonstrate how a rigorous analysis can inform

  20. Factors affecting date of implantation, parturition, and den entry estimated from activity and body temperature in free-ranging brown bears.

    Directory of Open Access Journals (Sweden)

    Andrea Friebe

    Full Text Available Knowledge of factors influencing the timing of reproduction is important for animal conservation and management. Brown bears (Ursus arctos are able to vary the birth date of their cubs in response to their fat stores, but little information is available about the timing of implantation and parturition in free-ranging brown bears. Body temperature and activity of pregnant brown bears is higher during the gestation period than during the rest of hibernation and drops at parturition. We compared mean daily body temperature and activity levels of pregnant and nonpregnant females during preimplantation, gestation, and lactation. Additionally we tested whether age, litter size, primiparity, environmental conditions, and the start of hibernation influence the timing of parturition. The mean date of implantation was 1 December (SD = 12, the mean date of parturition was 26 January (SD = 12, and the mean duration of the gestation period was 56 days (SD = 2. The body temperature of pregnant females was higher during the gestation and lactation periods than that of nonpregnant bears. The body temperature of pregnant females decreased during the gestation period. Activity recordings were also used to determine the date of parturition. The parturition dates calculated with activity and body temperature data did not differ significantly and were the same in 50% of the females. Older females started hibernation earlier. The start of hibernation was earlier during years with favorable environmental conditions. Dates of parturition were later during years with good environmental conditions which was unexpected. We suggest that free-ranging pregnant brown bears in areas with high levels of human activities at the beginning of the denning period, as in our study area, might prioritize investing energy in early denning than in early parturition during years with favorable environmental conditions, as a strategy to prevent disturbances caused by human.

  1. The effect of normal load on polytetrafluoroethylene tribology.

    Science.gov (United States)

    Barry, Peter R; Chiu, Patrick Y; Perry, Scott S; Sawyer, W Gregory; Phillpot, Simon R; Sinnott, Susan B

    2009-04-08

    The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.

  2. Load theory behind the wheel; perceptual and cognitive load effects.

    Science.gov (United States)

    Murphy, Gillian; Greene, Ciara M

    2017-09-01

    Perceptual Load Theory has been proposed as a resolution to the longstanding early versus late selection debate in cognitive psychology. There is much evidence in support of Load Theory but very few applied studies, despite the potential for the model to shed light on everyday attention and distraction. Using a driving simulator, the effect of perceptual and cognitive load on drivers' visual search was assessed. The findings were largely in line with Load Theory, with reduced distractor processing under high perceptual load, but increased distractor processing under high cognitive load. The effect of load on driving behaviour was also analysed, with significant differences in driving behaviour under perceptual and cognitive load. In addition, the effect of perceptual load on drivers' levels of awareness was investigated. High perceptual load significantly increased inattentional blindness and deafness, for stimuli that were both relevant and irrelevant to driving. High perceptual load also increased RTs to hazards. The current study helps to advance Load Theory by illustrating its usefulness outside of traditional paradigms. There are also applied implications for driver safety and roadway design, as the current study suggests that perceptual and cognitive load are important factors in driver attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Childhood Cumulative Risk and Later Allostatic Load

    DEFF Research Database (Denmark)

    Doan, Stacey N; Dich, Nadya; Evans, Gary W

    2014-01-01

    State, followed for 8 years (between the ages 9 and 17). Poverty- related stress was computed using the cumulative risk approach, assessing stressors across 9 domains, including environmental, psychosocial, and demographic factors. Allostatic load captured a range of physiological responses, including......Objective: The present study investigated the long-term impact of exposure to poverty-related stressors during childhood on allostatic load, an index of physiological dysregulation, and the potential mediating role of substance use. Method: Participants (n = 162) were rural children from New York...... cardiovascular, hypothalamic pituitary adrenal axis, sympathetic adrenal medullary system, and metabolic activity. Smoking and alcohol/drug use were tested as mediators of the hypothesized childhood risk-adolescent allostatic load relationship. Results: Cumulative risk exposure at age 9 predicted increases...

  4. C7L family of poxvirus host range genes inhibits antiviral activities induced by type I interferons and interferon regulatory factor 1.

    Science.gov (United States)

    Meng, Xiangzhi; Schoggins, John; Rose, Lloyd; Cao, Jingxin; Ploss, Alexander; Rice, Charles M; Xiang, Yan

    2012-04-01

    Vaccinia virus (VACV) K1L and C7L function equivalently in many mammalian cells to support VACV replication and antagonize antiviral activities induced by type I interferons (IFNs). While K1L is limited to orthopoxviruses, genes that are homologous to C7L are found in diverse mammalian poxviruses. In this study, we showed that the C7L homologues from sheeppox virus and swinepox virus could rescue the replication defect of a VACV mutant deleted of both K1L and C7L (vK1L(-)C7L(-)). Interestingly, the sheeppox virus C7L homologue could rescue the replication of vK1L(-)C7L(-) in human HeLa cells but not in murine 3T3 and LA-4 cells, in contrast to all other C7L homologues. Replacing amino acids 134 and 135 of the sheeppox virus C7L homologue, however, made it functional in the two murine cell lines, suggesting that these two residues are critical for antagonizing a putative host restriction factor which has some subtle sequence variation in human and murine cells. Furthermore, the C7L family of host range genes from diverse mammalian poxviruses were all capable of antagonizing type I IFN-induced antiviral activities against VACV. Screening of a library of more than 350 IFN-stimulated genes (ISGs) identified interferon-regulated factor 1 (IRF1) as an inhibitor of vK1L(-)C7L(-) but not wild-type VACV. Expression of either K1L or C7L, however, rendered vK1L(-)C7L(-) resistant to IRF1-induced antiviral activities. Altogether, our data show that K1L and C7L antagonize IRF1-induced antiviral activities and that the host modulation function of C7L is evolutionally conserved in all poxviruses that can readily replicate in tissue-cultured mammalian cells.

  5. Beam loading

    OpenAIRE

    Boussard, Daniel

    1987-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superco...

  6. Chloride concentrations, loads, and yields in four watersheds along Interstate 95, southeastern Connecticut, 2008-11: factors that affect peak chloride concentrations during winter storms

    Science.gov (United States)

    Brown, Craig J.; Mullaney, John R.; Morrison, Jonathan; Martin, Joseph W.; Trombley, Thomas J.

    2015-07-01

    Chloride (Cl-) concentrations and loads and other water chemistry characteristics were assessed to evaluate potential effects of road-deicer applications on streamwater quality in four watersheds along Interstate 95 (I–95) in southeastern Connecticut from November 1, 2008, through September 30, 2011. Streamflow and water quality were studied in the Four Mile River, Oil Mill Brook, Stony Brook, and Jordan Brook watersheds, where developed land ranged from 9 to 32 percent. Water-quality samples were collected and specific conductance was measured continuously at paired water-quality monitoring sites, upstream and downstream from I–95. Specific conductance values were related to Cl- concentrations to assist in determining the effects of road-deicing operations on the levels of Cl-in the streams. Streamflow and water-quality data were compared with weather data and with the timing, amount, and composition of deicers applied to State highways. Grab samples were collected during winter stormwater-runoff events, such as winter storms or periods of rain or warm temperatures in which melting takes place. Grab samples were also collected periodically during the spring and summer and during base-flow conditions.

  7. Biota Modeling in EPA's Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Karessa L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dolislager, Fredrick G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bellamy, Michael B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency's (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV's). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

  8. Biota Modeling in EPA's Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

    International Nuclear Information System (INIS)

    Manning, Karessa L.; Dolislager, Fredrick G.; Bellamy, Michael B.

    2016-01-01

    The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency's (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV's). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

  9. Data on respiratory variables in critically ill patients with acute respiratory failure placed on proportional assist ventilation with load adjustable gain factors (PAV+

    Directory of Open Access Journals (Sweden)

    Dimitris Georgopoulos

    2016-09-01

    Full Text Available The data show respiratory variables in 108 critically ill patients with acute respiratory failure placed on proportional assist ventilation with load adjustable gain factors (PAV+ after at least 36 h on passive mechanical ventilation. PAV+ was continued for 48 h until the patients met pre-defined criteria either for switching to controlled modes or for breathing without ventilator assistance. Data during passive mechanical ventilation and during PAV+ are reported. Data are acquired from the whole population, as well as from patients with and without acute respiratory distress syndrome. The reported variables are tidal volume, driving pressure (ΔP, the difference between static end-inspiratory plateau pressure and positive end-expiratory airway pressure, respiratory system compliance and resistance, and arterial blood gasses. The data are supplemental to our original research article, which described individual ΔP in these patients and examined how it related to ΔP when the same patients were ventilated with passive mechanical ventilation using the currently accepted lung-protective strategy “Driving pressure during assisted mechanical ventilation. Is it controlled by patient brain?” [1]. Keywords: Tidal volume, Compliance, Driving pressure

  10. Recruitment of the cohesin loading factor NIPBL to DNA double-strand breaks depends on MDC1, RNF168 and HP1γ in human cells

    International Nuclear Information System (INIS)

    Oka, Yasuyoshi; Suzuki, Keiji; Yamauchi, Motohiro; Mitsutake, Norisato; Yamashita, Shunichi

    2011-01-01

    Highlights: → NIPBL is recruited to DSBs. → Localization of NIPBL to DSBs is regulated by MDC1 and RNF168. → HP1γ is required for NIPBL accumulation at DSBs. -- Abstract: The cohesin loading factor NIPBL is required for cohesin to associate with chromosomes and plays a role in DNA double-strand break (DSB) repair. Although the NIPBL homolog Scc2 is recruited to an enzymatically generated DSB and promotes cohesin-dependent DSB repair in yeast, the mechanism of the recruitment remains poorly understood. Here we show that the human NIPBL is recruited to the sites of DNA damage generated by micro-irradiation as well as to the sites of DSBs induced by homing endonuclease, I-PpoI. The recruitment of NIPBL was impaired by RNAi-mediated knockdown of MDC1 or RNF168, both of which also accumulate at DSBs. We also show that the recruitment of NIPBL to the sites of DNA damage is mediated by its C-terminal region containing HEAT repeats and Heterochromatin protein 1 (HP1) interacting motif. Furthermore, NIPBL accumulation at damaged sites was also compromised by HP1γ depletion. Taken together, our study reveals that human NIPBL is a novel protein recruited to DSB sites, and the recruitment is controlled by MDC1, RNF168 and HP1γ.

  11. Understanding the synergistic effect and the main factors influencing the enzymatic hydrolyzability of corn stover at low enzyme loading by hydrothermal and/or ultrafine grinding pretreatment.

    Science.gov (United States)

    Zhang, Haiyan; Li, Junbao; Huang, Guangqun; Yang, Zengling; Han, Lujia

    2018-05-26

    A thorough assessment of the microstructural changes and synergistic effects of hydrothermal and/or ultrafine grinding pretreatment on the subsequent enzymatic hydrolysis of corn stover was performed in this study. The mechanism of pretreatment was elucidated by characterizing the particle size, specific surface area (SSA), pore volume (PV), average pore size, cellulose crystallinity (CrI) and surface morphology of the pretreated samples. In addition, the underlying relationships between the structural parameters and final glucose yields were elucidated, and the relative significance of the factors influencing enzymatic hydrolyzability were assessed by principal component analysis (PCA). Hydrothermal pretreatment at a lower temperature (170 °C) combined with ultrafine grinding achieved a high glucose yield (80.36%) at a low enzyme loading (5 filter paper unit (FPU)/g substrate) which is favorable. The relative significance of structural parameters in enzymatic hydrolyzability was SSA > PV > average pore size > CrI/cellulose > particle size. PV and SSA exhibited logarithmic correlations with the final enzymatic hydrolysis yield. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Probability Based Evaluation of Vehicular Bridge Load using Weigh-in-Motion Data

    Directory of Open Access Journals (Sweden)

    Widi Nugraha

    2016-02-01

    Full Text Available Load and Resistance Factored Design (LRFD method for designing bridge in Indonesia have been implemented for more than 25 years. LRFD method treating loads and strengths variables as random variables with specific safety factors for different loads and strengths variables type. The nominal loads, load factors, reduction factors, and other criteria for bridge design code can be determined to meet the reliability criteria. Statistical data of weigh-in-motion (WIM vehicular loads measurement in Northern Java highway, Cikampek - Pamanukan, West Java (2011, used in as statistical loads variable. A 25 m simple span bridge with reinforced concrete T-girder is used as a model for structural analysis due to WIM measured and nominal vehicular load based on RSNI T-02-2005, with applied bending moment of girder as the output. The distribution fitting result of applied bending moment due to WIM measured vehicular loads is lognormal. The maximum bending moment due to RSNI T-02-2005 nominal vehicular load is 842.45 kN-m and has probability of exceedance of 5x10-5. It can be concluded, for this study, that the bridge designed using RSNI T-02-2005 is safely designed, since it has reliability index, β of 5.02, higher than target reliability, β ranging from 3.50 or 3.72.

  13. An integrated analytical framework for quantifying the LCOE of waste-to-energy facilities for a range of greenhouse gas emissions policy and technical factors

    International Nuclear Information System (INIS)

    Townsend, Aaron K.; Webber, Michael E.

    2012-01-01

    This study presents a novel integrated method for considering the economics of waste-to-energy (WTE) facilities with priced greenhouse gas (GHG) emissions based upon technical and economic characteristics of the WTE facility, MSW stream, landfill alternative, and GHG emissions policy. The study demonstrates use of the formulation for six different policy scenarios and explores sensitivity of the results to ranges of certain technical parameters as found in existing literature. The study shows that details of the GHG emissions regulations have large impact on the levelized cost of energy (LCOE) of WTE and that GHG regulations can either increase or decrease the LCOE of WTE depending on policy choices regarding biogenic fractions from combusted waste and emissions from landfills. Important policy considerations are the fraction of the carbon emissions that are priced (i.e. all emissions versus only non-biogenic emissions), whether emissions credits are allowed due to reducing fugitive landfill gas emissions, whether biogenic carbon sequestration in landfills is credited against landfill emissions, and the effectiveness of the landfill gas recovery system where waste would otherwise have been buried. The default landfill gas recovery system effectiveness assumed by much of the industry yields GHG offsets that are very close to the direct non-biogenic GHG emissions from a WTE facility, meaning that small changes in the recovery effectiveness cause relatively larger changes in the emissions factor of the WTE facility. Finally, the economics of WTE are dependent on the MSW stream composition, with paper and wood being advantageous, metal and glass being disadvantageous, and plastics, food, and yard waste being either advantageous or disadvantageous depending upon the avoided tipping fee and the GHG emissions price.

  14. Killing Range

    Science.gov (United States)

    Asal, Victor; Rethemeyer, R. Karl; Horgan, John

    2015-01-01

    This paper presents an analysis of the Provisional Irish Republican Army's (PIRA) brigade level behavior during the Northern Ireland Conflict (1970-1998) and identifies the organizational factors that impact a brigade's lethality as measured via terrorist attacks. Key independent variables include levels of technical expertise, cadre age, counter-terrorism policies experienced, brigade size, and IED components and delivery methods. We find that technical expertise within a brigade allows for careful IED usage, which significantly minimizes civilian casualties (a specific strategic goal of PIRA) while increasing the ability to kill more high value targets with IEDs. Lethal counter-terrorism events also significantly affect a brigade's likelihood of killing both civilians and high-value targets but in different ways. Killing PIRA members significantly decreases IED fatalities but also significantly decreases the possibility of zero civilian IED-related deaths in a given year. Killing innocent Catholics in a Brigade's county significantly increases total and civilian IED fatalities. Together the results suggest the necessity to analyze dynamic situational variables that impact terrorist group behavior at the sub-unit level. PMID:25838603

  15. Chemical characterisation and source apportionment of PM1 during massive loading at an urban location in Indo-Gangetic Plain: impact of local sources and long-range transport

    Directory of Open Access Journals (Sweden)

    Prashant Rajput

    2016-07-01

    Full Text Available This study assesses temporal variability and source contributions of PM1 (particles with aerodynamic diameter ≤ 1.0 µm samples (n=51; November 2009–February 2010 from an urban location at Kanpur (26.30°N; 80.13°E; 142 m above mean sea-level in the Indo-Gangetic Plain (IGP. A study period from November to February is preferred owing to massive loading of particulate matter in entire IGP. PM1 varies from 18 to 348 (Avg±SD: 113±72 µg m−3 in this study. A total of 11 trace metals, five major elements and four water-soluble inorganic species (WSIS have been measured. Mass fraction of total metals (∑metals=trace+major centres at 18±14 %, of which nearly 15 % is contributed by major elements. Furthermore, ∑WSIS contributes about 26 % to PM1 mass concentration. Abundance pattern among assessed WSIS in this study follows the order: ≈> > Cl−. The K-to-PM1 mass fraction (Avg: 2 % in conjunction with air-mass back trajectories (AMBT indicates that the prevailing north-westerly winds transport biomass burning derived pollutants from upwind IGP. A recent version of positive matrix factorisation (PMF 5.0 has been utilised to quantify the contribution of fine-mode aerosols from various sources. The contribution from each source is highly variable and shows a strong dependence on AMBT. Events with predominant contribution from biomass burning emission (>70 % indicate origin of air-masses from source region upwind in IGP. One of the most interesting features of our study relates to the observation that secondary aerosols (contributing as high as ~60 % to PM1 loading are predominantly derived from stationary combustion sources (/ ratio: 0.30±0.23. Thus, our study highlights a high concentration of PM1 loading and atmospheric fog prevalent during wintertime can have a severe impact on atmospheric chemistry in the air-shed of IGP.

  16. Beam loading

    CERN Document Server

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  17. Beam loading

    International Nuclear Information System (INIS)

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed. (author)

  18. Climate control loads prediction of electric vehicles

    International Nuclear Information System (INIS)

    Zhang, Ziqi; Li, Wanyong; Zhang, Chengquan; Chen, Jiangping

    2017-01-01

    Highlights: • A model of vehicle climate control loads is proposed based on experiments. • Main climate control loads of the modeled vehicle are quantitatively analyzed. • Range reductions of the modeled vehicle under different conditions are simulated. - Abstract: A new model of electric vehicle climate control loads is provided in this paper. The mathematical formulations of the major climate control loads are developed, and the coefficients of the formulations are experimentally determined. Then, the detailed climate control loads are analyzed, and the New European Driving Cycle (NEDC) range reductions due to these loads are calculated under different conditions. It is found that in an electric vehicle, the total climate control loads vary with the vehicle speed, HVAC mode and blower level. The ventilation load is the largest climate control load, followed by the solar radiation load. These two add up to more than 80% of total climate control load in summer. The ventilation load accounts for 70.7–83.9% of total heating load under the winter condition. The climate control loads will cause a 17.2–37.1% reduction of NEDC range in summer, and a 17.1–54.1% reduction in winter, compared to the AC off condition. The heat pump system has an advantage in range extension. A heat pump system with an average heating COP of 1.7 will extend the range by 7.6–21.1% based on the simulation conditions.

  19. Peak load-impulse characterization of critical pulse loads in structural dynamics

    International Nuclear Information System (INIS)

    Abrahamson, G.R.; Lindberg, H.E.

    1975-01-01

    In presenting the characterization scheme, some general features are described first. A detailed analysis is given for the rigid-plastic system of one degree of freedom to illustrate the calculation of critical load curves in terms of peak load and impulse. This is followed by the presentation of critical load curves for uniformly loaded rigid-plastic beams and plates and for dynamic buckling of cylindrical shells under uniform lateral loads. The peak load-impulse characterization of critical pulse loads is compared with the dynamic load factor characterization, and some aspects of the history of the peak load-pulse scheme are presented. (orig./HP) [de

  20. Load sensor

    NARCIS (Netherlands)

    Van den Ende, D.; Almeida, P.M.R.; Dingemans, T.J.; Van der Zwaag, S.

    2007-01-01

    The invention relates to a load sensor comprising a polymer matrix and a piezo-ceramic material such as PZT, em not bedded in the polymer matrix, which together form a compos not ite, wherein the polymer matrix is a liquid crystalline resin, and wherein the piezo-ceramic material is a PZT powder

  1. Carbohydrate Loading.

    Science.gov (United States)

    Csernus, Marilyn

    Carbohydrate loading is a frequently used technique to improve performance by altering an athlete's diet. The objective is to increase glycogen stored in muscles for use in prolonged strenuous exercise. For two to three days, the athlete consumes a diet that is low in carbohydrates and high in fat and protein while continuing to exercise and…

  2. Factors associated with recent unsuppressed viral load in HIV-1-infected patients in care on first-line antiretroviral therapy in South Africa.

    Science.gov (United States)

    Joseph Davey, D; Abrahams, Z; Feinberg, M; Prins, M; Serrao, C; Medeossi, B; Darkoh, E

    2018-05-01

    Unsuppressed viral load (VL) in patients on antiretroviral therapy (ART) occurs when treatment fails to suppress a person's VL and is associated with decreased survival and increased HIV transmission. The objective of this study was to evaluate factors associated with unsuppressed VL (VL > 400 copies/ml) in patients currently in care on first-line ART for ≥ 6 months attending South African public healthcare facilities. We analysed electronic medical records of ART patients with a VL result on record who started ART between January 2004 and April 2016 from 271 public health facilities. We present descriptive and multivariable logistic regression for unsuppressed VL at last visit using a priori variables. We included 244,370 patients (69% female) on first-line ART in April 2016 for ≥ 6 months. Median age at ART start was 33 years (7% were < 15 years old). Median duration on ART was 3.7 years. Adjusting for other variables, factors associated with having an unsuppressed VL at the most recent visit among patients in care included: (1) < 15 years old at ART start (adjusted odds ratio [aOR]=2.58; 95% CI = 2.37, 2.81) versus 15-49 years at ART start, (2) male gender (aOR = 1.29; 95% CI = 1.25, 1.35), (3) 6-12 months on ART versus longer (aOR = 1.34; 95% CI = 1.29, 1.40), (4) on tuberculosis (TB) treatment (aOR = 1.78; 95% CI = 1.48, 2.13), and (5) prior ART exposure versus none (aOR = 1.20; 95% CI = 1.08, 1.32). Approximately 85% of the ART cohort who were in care had achieved viral suppression, though men, youth/adolescents, patients with prior ART exposure, those with short duration of ART, and patients on TB treatment had increased odds of not achieving viral suppression. There is a need to develop and evaluate targeted interventions for ART patients in care who are at high risk of unsuppressed VL.

  3. Seismic safety margins research program. Project VIII load combination project: work plan

    International Nuclear Information System (INIS)

    Chou, C.K.; Vepa, K.; George, L.; Smith, P.D.

    1979-01-01

    The proposed load combination project has the following overall objectives: develop a methodology for appropriate combination of dynamic loads for nuclear power plants under normal plant operation, transients, accidents, and natural hazards; establish design criteria, load factors, and component service levels for appropriate combinations of dynamic loads or responses to be used in nuclear power plant design; determine the reliability of typical piping systems, both inside and outside the containment structure, and provide the NRC with a sound technical basis for defining the criteria for postulating pipe breaks; and determine the probabilities of a large LOCA induced directly and indirectly by a range of earthquakes

  4. A Systematic Review on Immediate Loading of Implants Used to Support Overdentures Opposed by Conventional Prostheses: Factors That Might Influence Clinical Outcomes.

    Science.gov (United States)

    Zygogiannis, Kostas; Wismeijer, Daniel; Aartman, Irene Ha; Osman, Reham B

    2016-01-01

    Different treatment protocols in terms of number, diameter, and suprastructure design have been proposed for immediately loaded implants that are used to support mandibular overdentures opposed by maxillary conventional dentures. The aim of this study was to investigate the influence of these protocols on survival rates as well as clinical and prosthodontic outcomes. Several electronic databases were searched for all relevant articles published from 1966 to June 2014. Only randomized controlled trials and prospective studies with a minimum follow-up of 12 months were selected. The primary outcomes of interest were the success and survival rates of the implants. Prosthodontic complications were also evaluated. Fourteen studies fulfilled the inclusion criteria. Of the studies identified, nine were randomized controlled trials and five were prospective studies. The mean follow-up period was 3 years or less for the vast majority of the studies. The reported survival and success rates were comparable to that of conventional loading for most of the included studies. No specific immediate loading protocol seemed to perform better in terms of clinical and prosthodontic outcomes. Immediate loading protocols of mandibular overdentures seem to be a viable alternative to conventional loading. It was not possible to recommend a specific treatment protocol related to the number, diameter of the implants, and attachment system used. Long-term, well-designed studies comparing different immediate loading modalities could help to establish a protocol that delivers the most clinically predictable, efficient, and cost-effective outcome for edentulous patients in need of implant overdentures.

  5. Load sensor

    OpenAIRE

    Van den Ende, D.; Almeida, P.M.R.; Dingemans, T.J.; Van der Zwaag, S.

    2007-01-01

    The invention relates to a load sensor comprising a polymer matrix and a piezo-ceramic material such as PZT, em not bedded in the polymer matrix, which together form a compos not ite, wherein the polymer matrix is a liquid crystalline resin, and wherein the piezo-ceramic material is a PZT powder forming 30-60% by volume of the composite, and wherein the PZT powder forms 40-50% by volume of the composite.

  6. Behaviour of eggshell membranes at tensile loading

    Czech Academy of Sciences Publication Activity Database

    Strnková, M.J.; Nedomová, Š.; Trnka, Jan; Buchar, J.; Kumbár, V.

    46 B, December (2014), s. 44-48 ISSN 0324-1130 Institutional support: RVO:61388998 Keywords : eggshell membrane * tensile loading * loading rate * stress * strain strength Subject RIV: GM - Food Processing Impact factor: 0.201, year: 2014

  7. The stem factor challenge

    International Nuclear Information System (INIS)

    Russell, M.J.; Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Bramwell, D.

    1994-01-01

    One of the most important challenges that still needs to be met in the effort to understand the operation of motor-operated, rising-stem valves is the ability to determine stem factor throughout the valve's load range. The stem factor represents the conversion of operator torque to stem thrust. Determining the stem factor is important because some motor-operated valves (MOVs) cannot be tested in the plant at design basis conditions. The ability of these valves to perform their design basis function (typically, to operate against specified flow and pressure loads) must be ensured by analytical methods or by extrapolating from the results of tests conducted at lower loads. Because the stem factor tends to vary in response to friction and lubrication phenomena that occur during loading and wedging, analytical methods and extrapolation methods have been difficult to develop and implement. Early investigations into variability in the stem factor tended to look only at the tip of the iceberg; they focused on what was happening at torque switch trip, which usually occurs at full wedging. In most stems, the stem factor is better (lower) in the wedging transient than before wedging, so working with torque switch trip data alone led many early researchers to false conclusions about the relationship between stem factor and load. However, research at the Idaho National Engineering Laboratory (INEL) has taken a closer look at what happens during the running portion of the closing stroke along with the wedging portion. This shift in focus is important, because functional failure of a valve typically consists of a failure to isolate flow, not a failure to achieve full wedging. Thus, the stem factor that must be determined for a valve's design basis closing requirements is the one that corresponds with the running load before wedging

  8. Effect of water deprivation, desmopressin (DDAVP) infusion, and oral loads of water, Na+ and NH4+ on urinary excretion of epidermal growth factor in the rat

    DEFF Research Database (Denmark)

    Jørgensen, P E; Poulsen, Steen Seier; Nexø, Ebba

    1993-01-01

    for urinary EGF we examined the effects of changes in the oral loads of water, Na+ and NH4+ as well as the effect of infusion of the vasopressin analogue, desmopressin (DDAVP) on the endogenous urinary EGF excretion in the rat. Water deprivation for 48 h reduced the urinary excretion of EGF by 25...

  9. Load equivalency factors (LEFs) for abnormal vehicles (AVs) and mobile cranes in South Africa based on the mechanistic-empirical (M-E) design methodology

    CSIR Research Space (South Africa)

    De Beer, Morris

    2009-07-01

    Full Text Available layer life of pavement under the loading of Axle of vehicle in question. v n ii=1 Total Additional Damage of Vehicle = TAD (Ncritical from Standard 80 kN/520 kPa Axle) (Ncritical from Legal 88 kN/700 kPa Axle) -(Ncritical from Axle...

  10. A systematic review on immediate loading of implants used to support overdentures opposed by conventional prostheses : factors that might influence clinical outcomes

    NARCIS (Netherlands)

    Zygogiannis, K.; Wismeijer, D.; Aartman, I.H.A.; Osman, R.B.

    2016-01-01

    Purpose: Different treatment protocols in terms of number, diameter, and suprastructure design have been proposed for immediately loaded implants that are used to support mandibular overdentures opposed by maxillary conventional dentures. The aim of this study was to investigate the influence of

  11. The role of the vascular endothelial growth factor/vascular endothelial growth factor receptors axis mediated angiogenesis in curcumin-loaded nanostructured lipid carriers induced human HepG2 cells apoptosis

    Directory of Open Access Journals (Sweden)

    Fengling Wang

    2015-01-01

    Full Text Available Background: Curcumin (diferuloylmethane, the active constituent of turmeric extract has potent anti-cancer properties have been demonstrated in hepatocellular carcinoma (HCC. However, its underlying molecular mechanism of therapeutic effects remains unclear. Vascular endothelial growth factor (VEGF and its receptors (VEGFRs have crucial roles in tumor angiogenesis. Purpose: The goal of this study was to investigate the role of the VEGF/VEGFRs mediated angiogenesis during the proliferation and apoptosis of human HepG2 hepatoma cell line and the effect of curcumin-loaded nanostructured lipid carriers (Cur-NLC. Materials and Methods: The proliferation of HepG2 cells was determined by methyl thiazolyl tetrazolium after exposure to Cur-NLC and native curcumin. Apoptosis was quantified by flow cytometry with annexin V-fluorescein isothiocyanate and propidium iodide staining. Cellular internalization of Cur-NLC was observed by fluorescent microscope. The level of VEGF was detected by enzyme-linked immunosorbent assay kits. The expression of VEGFRs was quantified by Western blotting. Results: Cur-NLC was more effective in inhibiting the proliferation and enhancing the apoptosis of HepG2 cells than native curcumin. Fluorescent microscope analysis showed that HepG2 cells internalized Cur-NLC more effectively than native curcumin. Furthermore, Cur-NLC down-regulated the level of VEGF and the expression of VEGFR-2, but had a slight effect on VEGFR-1. Conclusion: These results clearly demonstrated that Cur-NLC was more effective in anti-cancer activity than the free form of curcumin. These studies demonstrate for the 1 st time that Cur-NLC exerts an antitumor effect on HepG2 cells by modulating VEGF/VEGFRs signaling pathway.

  12. Allostasis and allostatic load: implications for neuropsychopharmacology.

    Science.gov (United States)

    McEwen, B S

    2000-02-01

    The primary hormonal mediators of the stress response, glucocorticoids and catecholamines, have both protective and damaging effects on the body. In the short run, they are essential for adaptation, maintenance of homeostasis, and survival (allostasis). Yet, over longer time intervals, they exact a cost (allostatic load) that can accelerate disease processes. The concepts of allostasis and allostatic load center around the brain as interpreter and responder to environmental challenges and as a target of those challenges. In anxiety disorders, depressive illness, hostile and aggressive states, substance abuse, and post-traumatic stress disorder (PTSD), allostatic load takes the form of chemical imbalances as well as perturbations in the diurnal rhythm, and, in some cases, atrophy of brain structures. In addition, growing evidence indicates that depressive illness and hostility are both associated with cardiovascular disease (CVD) and other systemic disorders. A major risk factor for these conditions is early childhood experiences of abuse and neglect that increase allostatic load later in life and lead individuals into social isolation, hostility, depression, and conditions like extreme obesity and CVD. Animal models support the notion of lifelong influences of early experience on stress hormone reactivity. Whereas, depression and childhood abuse and neglect tend to be more prevalent in individuals at the lower end of the socioeconomic ladder, cardiovascular and other diseases follow a gradient across the full range of socioeconomic status (SES). An SES gradient is also evident for measures of allostatic load. Wide-ranging SES gradients have also been described for substance abuse and affective and anxiety disorders as a function of education. These aspects are discussed as important, emerging public health issues where the brain plays a key role.

  13. Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

    Energy Technology Data Exchange (ETDEWEB)

    Jeffers, M. A.; Chaney, L.; Rugh, J. P.

    2015-04-30

    Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

  14. Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis.

    Science.gov (United States)

    Papaspyridakos, Panos; Chen, Chun-Jung; Chuang, Sung-Kiang; Weber, Hans-Peter

    2014-01-01

    To report on the effect of immediate implant loading with fixed prostheses compared to early and conventional loading on implant and prosthesis survival, failure, and complications. An electronic and manual search was conducted to identify randomized controlled clinical trials (RCTs) as well as prospective and retrospective studies involving rough surface implants and implant fixed complete dental prostheses for edentulous patients. The 62 studies that fulfilled the inclusion criteria featured 4 RCTs, 2 prospective case-control studies, 34 prospective cohort studies, and 22 retrospective cohort studies. These studies yielded data from 2,695 patients (2,757 edentulous arches) with 13,653 implants. Studies were grouped according to the loading protocol applied; 45 studies reported on immediate loading, 8 on early loading, and 11 on conventional loading. For the immediate loading protocol with flap surgery, the implant and prosthesis survival rates ranged from 90.1% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). When immediate loading was combined with guided flapless implant placement, the implant survival rates ranged from 90% to 99.4%. For the early loading protocol, the implant and prosthesis survival rates ranged from 94.74% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). For the conventional loading protocol, the implant and prosthesis survival rates ranged from 94.95% to 100% and 87.5% to 100%, respectively (range of follow-up, 2 to 15 years). No difference was identified between maxilla and mandible. When selecting cases carefully and using dental implants with a rough surface, immediate loading with fixed prostheses in edentulous patients results in similar implant and prosthesis survival and failure rates as early and conventional loading. For immediate loading, most of the studies recommended a minimal insertion torque of 30 Ncm. The estimated 1-year implant survival was above 99% with all three

  15. Stateful load balancing for parallel stream processing

    DEFF Research Database (Denmark)

    Guo, Qingsong; Zhou, Yongluan

    2018-01-01

    -objective optimization problem, namely Minimum-Cost-Load-Balance (MCLB). We address MCLB with two approximate algorithms by a certain relaxation of the objectives: (1) a greedy algorithm ELB performs load balancing eagerly but relaxes the objective of load imbalance to a range; and (2) a periodic algorithm CLB aims...

  16. Home range and travels

    Science.gov (United States)

    Stickel, L.F.; King, John A.

    1968-01-01

    The concept of home range was expressed by Seton (1909) in the term 'home region,' which Burr (1940, 1943) clarified with a definition of home range and exemplified in a definitive study of Peromyscus in the field. Burt pointed out the ever-changing characteristics of home-range area and the consequent absence of boundaries in the usual sense--a finding verified by investigators thereafter. In the studies summarized in this paper, sizes of home ranges of Peromyscus varied within two magnitudes, approximately from 0.1 acre to ten acres, in 34 studies conducted in a variety of habitats from the seaside dunes of Florida to the Alaskan forests. Variation in sizes of home ranges was correlated with both environmental and physiological factors; with habitat it was conspicuous, both in the same and different regions. Food supply also was related to size of home range, both seasonally and in relation to habitat. Home ranges generally were smallest in winter and largest in spring, at the onset of the breeding season. Activity and size also were affected by changes in weather. Activity was least when temperatures were low and nights were bright. Effects of rainfall were variable. Sizes varied according to sex and age; young mice remained in the parents' range until they approached maturity, when they began to travel more widely. Adult males commonly had larger home ranges than females, although there were a number of exceptions. An inverse relationship between population density and size of home range was shown in several studies and probably is the usual relationship. A basic need for activity and exploration also appeared to influence size of home range. Behavior within the home range was discussed in terms of travel patterns, travels in relation to home sites and refuges, territory, and stability of size of home range. Travels within the home range consisted of repeated use of well-worn trails to sites of food, shelter, and refuge, plus more random exploratory travels

  17. Effect of operational factors on bioregeneration of binary phenol and 4-chlorophenol-loaded granular activated carbon using PVA-immobilized biomass cryogels.

    Science.gov (United States)

    Leong, Kwok-Yii; Adnan, Rohana; Lim, Poh-Eng; Ng, Si-Ling; Seng, Chye-Eng

    2017-09-01

    The effects of dry biomass density in cryogel beads, shaking speed and initial concentration ratio of phenol to 4-chlorophenol (4-CP) on the bioregeneration efficiencies of binary phenol and 4-CP-loaded granular activated carbon (GAC) for phenol and 4-CP, respectively, were investigated under the simultaneous adsorption and biodegradation approach. The results revealed higher bioregeneration efficiencies of binary-loaded GAC for phenol and 4-CP at higher dry biomass density but moderate shaking speed. The optimum dry biomass density in cryogel beads and shaking speed for use in bioregeneration were found to be 0.01 g/mL and 250 rpm, respectively. With respect to the initial phenol to 4-CP concentration ratio, the bioregeneration efficiencies were lower under increasing phenol and 4-CP initial concentrations, respectively, with the effect being more conspicuous under increasing 4-CP concentration. Higher bioregeneration efficiencies were achieved with the use of immobilized rather than suspended biomasses.

  18. Evaluation of hip internal and external rotation range of motion as an injury risk factor for hip, abdominal and groin injuries in professional baseball players

    Directory of Open Access Journals (Sweden)

    Xinning Li

    2015-12-01

    Full Text Available Normal hip range of motion (ROM is essential in running and transfer of energy from lower to upper extremities during overhead throwing. Dysfunctional hip ROM may alter lower extremity kinematics and predispose athletes to hip and groin injuries. The purpose of this study is characterize hip internal/external ROM (Arc and its effect on the risk of hip, hamstring, and groin injuries in professional baseball players. Bilateral hip internal and external ROM was measured on all baseball players (N=201 in one professional organization (major and minor league during spring training. Players were organized according to their respective positions. All injuries were documented prospectively for an entire MLB season (2010 to 2011. Data was analyzed according to position and injuries during the season. Total number of players (N=201 with an average age of 24±3.6 (range=17-37. Both pitchers (N=93 and catchers (N=22 had significantly decreased mean hip internal rotation and overall hip arc of motion compared to the positional players (N=86. Players with hip, groin, and hamstring injury also had decreased hip rotation arc when compared to the normal group. Overall, there is a correlation between decreased hip internal rotation and total arc of motion with hip, hamstring, and groin injuries.

  19. The pion electromagnetic form factor in the time-like energy range 1.35≤√s≤2.4 GeV

    International Nuclear Information System (INIS)

    1988-10-01

    The e + e - → π + π - cross section has been measured from about 280 events (an order of magnitude more than the previous world statistics) in the energy interval 1.35≤√s≤2.4 GeV with the DM2 detector at DCI. The pion squared form factor shows a deep minimum around 1.6 GeV/c 2 and is best fit under the hypothesis of two ρ like resonances ≅ 0.2 GeV/c 2 wide with 1.43 and 1.76 GeV/c 2 masses

  20. Load Estimation from Natural input Modal Analysis

    DEFF Research Database (Denmark)

    Aenlle, Manuel López; Brincker, Rune; Canteli, Alfonso Fernández

    2005-01-01

    One application of Natural Input Modal Analysis consists in estimating the unknown load acting on structures such as wind loads, wave loads, traffic loads, etc. In this paper, a procedure to determine loading from a truncated modal model, as well as the results of an experimental testing programme...... estimation. In the experimental program a small structure subjected to vibration was used to estimate the loading from the measurements and the experimental modal space. The modal parameters were estimated by Natural Input Modal Analysis and the scaling factors of the mode shapes obtained by the mass change...

  1. Load testing circuit

    DEFF Research Database (Denmark)

    2009-01-01

    A load testing circuit a circuit tests the load impedance of a load connected to an amplifier. The load impedance includes a first terminal and a second terminal, the load testing circuit comprising a signal generator providing a test signal of a defined bandwidth to the first terminal of the load...

  2. Some pollinators are more equal than others: Factors influencing pollen loads and seed set capacity of two actively and passively pollinating fig wasps

    Science.gov (United States)

    Kjellberg, Finn; Suleman, Nazia; Raja, Shazia; Tayou, Abelouahad; Hossaert-McKey, Martine; Compton, Stephen G.

    2014-05-01

    The nursery pollination system of fig trees (Ficus) results in the plants providing resources for pollinator fig wasp larvae as part of their male reproductive investment, with selection determining relative investment into pollinating wasps and the pollen they carry. The small size of Ficus pollen suggests that the quantities of pollen transported by individual wasps often limits male reproductive success. We assessed variation in fig wasp pollen loads and its influence on seed production in actively pollinated (Ficus montana) and passively pollinated (Ficus carica) dioecious fig trees.

  3. PERFORMANCE OF HIGH SCHOOL FOOTBALL PLAYERS ON CLINICAL MEASURES OF DEEP CERVICAL FLEXOR ENDURANCE AND CERVICAL ACTIVE RANGE OF MOTION: IS HISTORY OF CONCUSSION A FACTOR?

    Science.gov (United States)

    Smith, Laura; Ruediger, Thomas; Alsalaheen, Bara; Bean, Ryan

    2016-04-01

    More than one million adolescent athletes participated in organized high school sanctioned football during the 2014-15 season. These athletes are at risk for sustaining concussion. Although cervical spine active range of motion (AROM) and deep neck flexor endurance may serve a preventative role in concussion, and widespread clinical use of measurements of these variables, reference values are not available for this population. Cost effective, clinically relevant methods for measuring neck endurance are also well established for adolescent athletes. The purpose of this study was to report reference values for deep cervical flexor endurance and cervical AROM in adolescent football players and examine whether differences in these measures exist in high school football players with and without a history of concussion. Concussion history, cervical AROM, and deep neck flexor endurance were measured in 122 high school football players. Reference values were calculated for AROM and endurance measures; association were examined between various descriptive variables and concussion. No statistically significant differences were found between athletes with a history of concussion and those without. A modest inverse correlation was seen between body mass and AROM in the sagittal and transverse planes. The results of this study indicate that the participants with larger body mass had less cervical AROM in some directions. While cervical AROM and endurance measurements may not be adequate to identify adolescents with a history of previous concussions among high school football players. However, if a concussion is sustained, these measures can offer a baseline to examine whether cervical AROM is affected as compared to healthy adolescents. 2c.

  4. Loads and loads and loads: The influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Directory of Open Access Journals (Sweden)

    Beat eMeier

    2015-06-01

    Full Text Available In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load can affect prospective memory performance. The existence of multiple target events increases prospective load and adding complexity to the to-be-remembered action increases retrospective load. In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of prospective load on costs in the ongoing task for categorical targets (Experiment 2, but not for specific targets (Experiment 1. Retrospective load and ongoing task load both affected remembering the retrospective component of the prospective memory task. We suggest that prospective load can enhance costs in the ongoing task due to additional monitoring requirements. Retrospective load and ongoing task load seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  5. Long-range gene flow and the effects of climatic and ecological factors on genetic structuring in a large, solitary carnivore: the Eurasian lynx.

    Directory of Open Access Journals (Sweden)

    Mirosław Ratkiewicz

    microsatellite population divergence patterns with climatic and ecological factors may suggest separate selective pressures acting on males and females in this solitary carnivore.

  6. Factors affecting occupational therapists' decision to join their regional professional association: Facteurs influençant la décision des ergothérapeutes de joindre les rangs de leur association professionnelle régionale.

    Science.gov (United States)

    Reyes, Angelica N; Brown, Cary A

    2018-01-01

    Voluntary occupational therapy organizations fill an important role. However, recruitment and retention can be problematic. Little is known about factors influencing occupational therapists to join/maintain membership in professional associations. This study investigated factors influencing occupational therapists' decision to join/remain members of their association. An electronic survey was carried out and data were analyzed using SPSS software and manual categorization of open-ended comments. Two hundred and fifty-four therapists responded. Generation of new ideas, opportunities for professional development, self-improvement, maintenance of standards, improvement of the profession, and discounts on equipment/educational opportunities were significant factors in deciding to join the organization. The factors perceived as priorities varied in relation to participants' year of graduation. More-customized strategies, reflecting priorities that vary during a therapist's career path, may need to be employed to best address recruitment and retention across the range of therapists' needs and goals.

  7. Seasonal response of ghrelin, growth hormone, and insulin-like growth factor I in the free-ranging Florida manatee (Trichechus manatus latirostris)

    Science.gov (United States)

    Tighe, Rachel L; Bonde, Robert K.; Avery, Julie P.

    2016-01-01

    Seasonal changes in light, temperature, and food availability stimulate a physiological response in an animal. Seasonal adaptations are well studied in Arctic, Sub-Arctic, and hibernating mammals; however, limited studies have been conducted in sub-tropical species. The Florida manatee (Trichechus manatus latirostris), a sub-tropical marine mammal, forages less during colder temperatures and may rely on adipose stores for maintenance energy requirements. Metabolic hormones, growth hormone (GH), insulin-like growth factor (IGF)-I, and ghrelin influence growth rate, accretion of lean and adipose tissue. They have been shown to regulate seasonal changes in body composition. The objective of this research was to investigate manatee metabolic hormones in two seasons to determine if manatees exhibit seasonality and if these hormones are associated with seasonal changes in body composition. In addition, age related differences in these metabolic hormones were assessed in multiple age classes. Concentrations of GH, IGF-I, and ghrelin were quantified in adult manatee serum using heterologous radioimmunoassays. Samples were compared between short (winter) and long (summer) photoperiods (n = 22 male, 20 female) and by age class (adult, juvenile, and calf) in long photoperiods (n = 37). Short photoperiods tended to have reduced GH (p = 0.08), greater IGF-I (p = 0.01), and greater blubber depth (p = 0.03) compared with long photoperiods. No differences were observed in ghrelin (p = 0.66). Surprisingly, no age related differences were observed in IGF-I or ghrelin concentrations (p > 0.05). However, serum concentrations of GH tended (p = 0.07) to be greater in calves and juveniles compared with adults. Increased IGF-I, greater blubber thickness, and reduced GH during short photoperiod suggest a prioritization for adipose deposition. Whereas, increased GH, reduced blubber thickness, and decreased IGF-I in long photoperiod suggest prioritization of lean tissue

  8. Factors controlling present-day tufa dynamics in the Monasterio de Piedra Natural Park (Iberian Range, Spain): depositional environmental settings, sedimentation rates and hydrochemistry

    Science.gov (United States)

    Vázquez-Urbez, M.; Arenas, C.; Sancho, C.; Osácar, C.; Auqué, L.; Pardo, G.

    2010-07-01

    The tufa record and hydrochemical characteristics of the River Piedra in the Monasterio de Piedra Natural Park (NE Spain) were studied for 6 years. The mean discharge of this river was 1.22 m3/s. The water was supersaturated with calcium carbonate. The HCO3 -, Ca2+ and TDIC concentrations decreased along the 0.5-km-long studied stretch, whereas the calcite SI showed no systematic downstream or seasonal variation over the same stretch. Several sedimentary subenvironments exist in which four broad types of tufa facies form: (1) Dense laminated tufa (stromatolites), (2) Dense to porous, massive tufa, (3) Porous, coarsely laminated tufa with bryophytes and algae, and (4) Dense, hard, laminated deposits in caves. The half-yearly period thickness and weight of sediment accumulated on 14 tablets installed in several subenvironments showed that the deposition rate was greater in fast flowing river areas and in stepped waterfalls, and lower in slow flowing or standing river areas and in spray and splash areas. Mechanical CO2 outgassing is the main factor controlling calcite precipitation on the river bed and in waterfalls, but this process does not explain the seasonal changes in depositional rates. The deposition rates showed a half-yearly period pattern recorded in all fluvial subenvironments persistent over time (5.26 mm, 0.86 g/cm2 in warm periods; 2.26 mm, 0.13 g/cm2 in cool periods). Mass balance calculations showed higher calcite mass values in warm (21.58 mg/L) than in cool (13.68 mg/L) periods. This biannual variation is mainly attributed to the seasonal differences in temperature that caused changes in inorganic calcite precipitation rate and in biomass and the correlative photosynthetic activity. Tufa sedimentation was therefore controlled by both physicochemical and biological processes. The results of this study may help test depositional rates and their environmental controls and thus assess the climatic and hydrological significance of ancient tufas in semi

  9. A Comparison of Tropical Storm (TS) and Non-TS Gust Factors for Assessing Peak Wind Probabilities at the Eastern Range

    Science.gov (United States)

    Merceret, Francis J.; Crawford, Winifred C.

    2010-01-01

    Peak wind speed is an important forecast element to ensure the safety of personnel and flight hardware at Kennedy Space Center (KSC) and the Cape Canaveral Air Force Station (CCAFS) in East-Central Florida. The 45th Weather Squadron (45 WS), the organization that issues forecasts for the KSC/CCAFS area, finds that peak winds are more difficult to forecast than mean winds. This difficulty motivated the 45 WS to request two independent studies. The first (Merceret 2009) was the development of a reliable model for gust factors (GF) relating the peak to the mean wind speed in tropical storms (TS). The second (Lambert et al. 2008) was a climatological study of non-TS cool season (October-April) mean and peak wind speeds by the Applied Meteorology Unit (AMU; Bauman et al. 2004) without the use of GF. Both studies presented their statistics as functions of mean wind speed and height. Most of the few comparisons of TS and non-TS GF in the literature suggest that non-TS GF at a given height and mean wind speed are smaller than the corresponding TS GF. The investigation reported here converted the non-TS peak wind statistics calculated by the AMU to the equivalent GF statistics and compared them with the previous TS GF results. The advantage of this effort over all previously reported studies of its kind is that the TS and non-TS data were taken from the same towers in the same locations. This eliminates differing surface attributes, including roughness length and thermal properties, as a major source of variance in the comparison. The goal of this study is two-fold: to determine the relationship between the non-TS and TS GF and their standard deviations (GFSD) and to determine if models similar to those developed for TS data in Merceret (2009) could be developed for the non-TS environment. The results are consistent with the literature, but include much more detailed, quantitative information on the nature of the relationship between TS and non-TS GF and GFSD as a function

  10. Secretion of human epidermal growth factor (EGF) in autotrophic culture by a recombinant hydrogen-utilizing bacterium, Pseudomonas pseudoflava, carrying broad-host-range EGF secretion vector pKSEGF2.

    OpenAIRE

    Hayase, N; Ishiyama, A; Niwano, M

    1994-01-01

    We constructed the broad-host-range human epidermal growth factor (EGF) secretion plasmid pKSEGF2 by inserting the Escherichia coli tac promoter, the signal sequence of Pseudomonas stutzeri amylase, and the synthesized EGF gene into the broad-host-range vector pKT230. E. coli JM109 carrying pKSEGF2 secreted EGF into the periplasm and the culture medium under the control of the tac promoter. Pseudomonas aeruginosa PAO1161 carrying pKSEGF2 and Pseudomonas putida AC10 carrying pKSEGF2 secreted E...

  11. POPs in free-ranging pilot whales, sperm whales and fin whales from the Mediterranean Sea: Influence of biological and ecological factors

    Energy Technology Data Exchange (ETDEWEB)

    Pinzone, Marianna [Laboratory of Oceanology, MARE Centre, B6c, University of Liege, B6c, Allée du 6 Août, 4000 Liege (Belgium); Budzinski, Hélène [ISM/LPTC, Laboratory of Physical and Chemical Chemistry, University of Bordeaux I, 351 Cours de la Libération, 33405 Bordeaux (France); CNRS, EPOC, UMR 5805, F-33400 Talence (France); Tasciotti, Aurélie; Ody, Denis [WWF-France, 6 Rue des Fabres, 13001 Marseille France (France); Lepoint, Gilles; Schnitzler, Joseph [Laboratory of Oceanology, MARE Centre, B6c, University of Liege, B6c, Allée du 6 Août, 4000 Liege (Belgium); Scholl, George [CART, Laboratory of Mass Spectrometry LSM, University of Liege, B6C, Allée du 6 Août, 4000, Liege (Belgium); Thomé, Jean-Pierre [CART, Laboratory of Animal Ecology and Ecotoxicology LEAE, University of Liege, B6c, Allée du 6 Août 11, 4000 Liege (Belgium); Tapie, Nathalie [ISM/LPTC, Laboratory of Physical and Chemical Chemistry, University of Bordeaux I, 351 Cours de la Libération, 33405 Bordeaux (France); CNRS, EPOC, UMR 5805, F-33400 Talence (France); Eppe, Gauthier [CART, Laboratory of Mass Spectrometry LSM, University of Liege, B6C, Allée du 6 Août, 4000, Liege (Belgium); Das, Krishna, E-mail: krishna.das@ulg.ac.be [Laboratory of Oceanology, MARE Centre, B6c, University of Liege, B6c, Allée du 6 Août, 4000 Liege (Belgium)

    2015-10-15

    related to sex than trophic level, with males presenting higher contaminant burden than females. The discriminant analysis (DA) confirmed how DDTs and highly chlorinated PCBs were influential in differentiating the three species. Pollutant concentrations of our species were significantly higher than both their Southern Hemisphere and North Atlantic counterparts, possibly due to the particular Mediterranean geomorphology, which influences pollutants distribution and recycle. Dioxin-like PCBs accounted for over 80% of the total TEQ. This study demonstrated (1) an important exposure to pollutants of Mediterranean cetaceans, often surpassing the estimated threshold toxicity value of 17,000 ng g{sup −1} lw for blubber in marine mammals; and (2) how the final pollutant burden in these animals is strongly influenced not only by the trophic position but also by numerous other factors such as sex, age, body size and geographical distribution. - Highlights: • We analysed POPs concentrations in cetaceans from North-western Mediterranean Sea. • We integrated δ{sup 13}C and δ{sup 15}N values to combine trophic position and contamination. • Odontocetes show PCBs level higher than the toxicity threshold of 17 μg g{sup −1} lw. • Trophic position, sex, body size and distribution affect interspecies diversity.

  12. POPs in free-ranging pilot whales, sperm whales and fin whales from the Mediterranean Sea: Influence of biological and ecological factors

    International Nuclear Information System (INIS)

    Pinzone, Marianna; Budzinski, Hélène; Tasciotti, Aurélie; Ody, Denis; Lepoint, Gilles; Schnitzler, Joseph; Scholl, George; Thomé, Jean-Pierre; Tapie, Nathalie; Eppe, Gauthier; Das, Krishna

    2015-01-01

    contaminant burden than females. The discriminant analysis (DA) confirmed how DDTs and highly chlorinated PCBs were influential in differentiating the three species. Pollutant concentrations of our species were significantly higher than both their Southern Hemisphere and North Atlantic counterparts, possibly due to the particular Mediterranean geomorphology, which influences pollutants distribution and recycle. Dioxin-like PCBs accounted for over 80% of the total TEQ. This study demonstrated (1) an important exposure to pollutants of Mediterranean cetaceans, often surpassing the estimated threshold toxicity value of 17,000 ng g −1 lw for blubber in marine mammals; and (2) how the final pollutant burden in these animals is strongly influenced not only by the trophic position but also by numerous other factors such as sex, age, body size and geographical distribution. - Highlights: • We analysed POPs concentrations in cetaceans from North-western Mediterranean Sea. • We integrated δ 13 C and δ 15 N values to combine trophic position and contamination. • Odontocetes show PCBs level higher than the toxicity threshold of 17 μg g −1 lw. • Trophic position, sex, body size and distribution affect interspecies diversity.

  13. Calculation of elastic-plastic strain ranges for fatigue analysis based on linear elastic stresses

    International Nuclear Information System (INIS)

    Sauer, G.

    1998-01-01

    Fatigue analysis requires that the maximum strain ranges be known. These strain ranges are generally computed from linear elastic analysis. The elastic strain ranges are enhanced by a factor K e to obtain the total elastic-plastic strain range. The reliability of the fatigue analysis depends on the quality of this factor. Formulae for calculating the K e factor are proposed. A beam is introduced as a computational model for determining the elastic-plastic strains. The beam is loaded by the elastic stresses of the real structure. The elastic-plastic strains of the beam are compared with the beam's elastic strains. This comparison furnishes explicit expressions for the K e factor. The K e factor is tested by means of seven examples. (orig.)

  14. A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements.

    Science.gov (United States)

    Liu, Feng; Feng, Li; Wang, Junyuan

    2018-07-01

    Edge loading in ceramic-on-ceramic total hip joint replacement is an adverse condition that occurs as the result of a direct contact between the head and the cup rim. It has been associated with translational mismatch in the centres of rotation of the cup and head, and found to cause severe wear and early failure of the implants. Edge loading has been considered in particular in relation to dynamic separation of the cup and head centres during a gait cycle. Research has been carried out both experimentally and computationally to understand the mechanism including the influence of bearing component positioning on the occurrence and severity of edge loading. However, it is experimentally difficult to measure both the load magnitude and duration of edge loading as it occurs as a short impact within the tight space of hip joints. Computationally, a dynamic contact model, for example, developed using the MSC ADAMS software for a multi-body dynamics simulation can be particularly useful for calculating the loads and characterising the edge loading. The aim of the present study was to further develop the computational model, and improve the predictions of contact force and the understanding of mechanism in order to provide guidance on design and surgical factors to avoid or to reduce edge loading and wear. The results have shown that edge loading can be avoided for a low range of translational mismatch in the centres of rotation of the cup and head during gait at the level of approximately 1.0 mm for a cup at 45° inclination, keeping a correct cup inclination at 45° is important to reduce the edge loading severity, and edge loading can be avoided for a certain range of translational mismatch of the cup and head centres with an increased swing phase load. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body

    NARCIS (Netherlands)

    Faber, G.S.; Kingma, I.; Bakker, A.J.; van Dieen, J.H.

    2009-01-01

    Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10

  16. Drug Loading of Mesoporous Silicon

    Science.gov (United States)

    Moffitt, Anne; Coffer, Jeff; Wang, Mengjia

    2011-03-01

    The nanostructuring of crystalline solids with low aqueous solubilities by their incorporation into mesoporous host materials is one route to improve the bioavailability of such solids. Earlier studies suggest that mesoporous Si (PSi), with pore widths in the range of 5-50 nm, is a candidate for such an approach. In this presentation, we describe efforts to load curcumin into free-standing microparticles of PSi. Curcumin is a compound extracted from turmeric root, which is an ingredient of curry. Curucmin has shown activity against selected cancer cell lines, bacteria, and other medical conditions. However, curcumin has a very low bioavailability due to its extremely low water solubility (0.6 μ g/mL). Incorporation of curcumin was achieved by straightforward loading of the molten solid at 185circ; C. Loading experiments were performed using PSi particles of two different size ranges, 45-75 μ m and 150-250 μ m. Longer loading times and ratio of curcumin to PSi leads to a higher percentage of loaded curcumin in both PSi particle sizes (as determined by weight difference). The extent of curcumin crystallinity was assessed by x-ray diffraction (XRD). The solubility and release kinetics of loaded curcumin from the PSi was determined by extraction into water at 37circ; C, with analysis using UV-VIS spectrometry. NSF-REU and TCU.

  17. The importance of thermal loading conditions to waste package performance at Yucca Mountain

    International Nuclear Information System (INIS)

    Buscheck, T.A.; Nitao, J.J.

    1994-10-01

    Temperature and relative humidity are primary environmental factors affecting waste package corrosion rates for the potential repository in the unsaturated zone at Yucca Mountain, Nevada. Under ambient conditions, the repository environment is quite humid. If relative humidity is low enough (<70%), corrosion will be minimal. Under humid conditions, corrosion is reduced if the temperature is low (<60 C). Using the V-TOUGH code, the authors model thermo-hydrological flow to investigate the effect of repository heat on temperature and relative humidity in the repository for a wide range of thermal loads. These calculations indicate that repository heat may substantially reduce relative humidity on the waste package, over hundreds of years for low thermal loads and over tens of thousands of year for high thermal loads. Temperatures associated with a given relative humidity decrease with increasing thermal load. Thermal load distributions can be optimized to yield a more uniform reduction in relative humidity during the boiling period

  18. Air permeability for a concrete shear wall after a damaging seismic load simulation cycle

    International Nuclear Information System (INIS)

    Girrens, S.P.; Farrar, C.R.

    1991-01-01

    A study was initiated to estimate air leakage, driven by wind-generated pressure gradients, from a seismically damaged concrete structure. This paper describes an experiment performed to measure the air permeability in a reinforced concrete shear wall, both before and after simulated seismic loading. Static load-cycle testing was used to simulate earthquake loading. Permeability measurements were made by pressurizing one side of the shear wall above atmospheric conditions and recording the transient-pressure decay. Air permeability measurements made on the shear wall before loading fell within the range of values for concrete permeability published in the literature. As long as the structure exhibited linear load-displacement response, no variation in the air permeability was detected. However, experimental results indicate that the air permeability in the shear wall increased by a factor of 40 after the wall had been damaged (cracked)

  19. Distribution load estimation (DLE)

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A; Lehtonen, M [VTT Energy, Espoo (Finland)

    1998-08-01

    The load research has produced customer class load models to convert the customers` annual energy consumption to hourly load values. The reliability of load models applied from a nation-wide sample is limited in any specific network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to find improvements to the load models or, in general, improvements to the load estimates. In Distribution Load Estimation (DLE) the measurements from the network are utilized to improve the customer class load models. The results of DLE will be new load models that better correspond to the loading of the distribution network but are still close to the original load models obtained by load research. The principal data flow of DLE is presented

  20. Load flow analysis using decoupled fuzzy load flow under critical ...

    African Journals Online (AJOL)

    user

    3.1 Maximum range selection of input and output variables: ..... Wong K. P., Li A., and Law M.Y., “ Advanced Constrained Genetic Algorithm Load Flow Method”, IEE Proc. ... Dr. Parimal Acharjee passed B.E.E. from North Bengal University ...

  1. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A. [VTT Energy, Espoo (Finland)

    1996-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  2. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A [VTT Energy, Espoo (Finland)

    1997-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  3. Intelligence Tests with Higher G-Loadings Show Higher Correlations with Body Symmetry: Evidence for a General Fitness Factor Mediated by Developmental Stability

    Science.gov (United States)

    Prokosch, M.D.; Yeo, R.A.; Miller, G.F.

    2005-01-01

    Just as body symmetry reveals developmental stability at the morphological level, general intelligence may reveal developmental stability at the level of brain development and cognitive functioning. These two forms of developmental stability may overlap by tapping into a ''general fitness factor.'' If so, then intellectual tests with higher…

  4. ICRF [ion cyclotron range of frequencies] coupling on DIII-D and the implications on ICRF technology development

    International Nuclear Information System (INIS)

    Hoffman, D.J.; Baity, F.W.; Mayberry, M.J.; Swain, D.W.

    1987-01-01

    Low-power coupling tests have been carried out with a prototype ion cyclotron range of frequencies (ICRF) compact loop antenna on the DIII-D tokamak. Plasma load resistance values higher than originally calculated are measured in ohmic and L-mode, beam-heated plasmas. Load resistance decreases by a factor of ∼2 in H-mode operation. When edge localized modes (ELMs) occur, the antenna loading increases transiently to several ohms. Results indicate that fast-wave ICRF antenna coupling characteristics are highly sensitive to changes in the edge plasma profiles associated with the H-mode regime

  5. Plastic Limit Loads for Slanted Circumferential Through-Wall Cracked Pipes Using 3D Finite-Element Limit Analyses

    International Nuclear Information System (INIS)

    Jang, Hyun Min; Cho, Doo Ho; Kim, Young Jin; Huh, Nam Su; Shim, Do Jun; Choi, Young Hwan; Park, Jung Soon

    2011-01-01

    On the basis of detailed 3D finite-element (FE) limit analyses, the plastic limit load solutions for pipes with slanted circumferential through-wall cracks (TWCs) subjected to axial tension, global bending, and internal pressure are reported. The FE model and analysis procedure employed in the present numerical study were validated by comparing the present FE results with existing solutions for plastic limit loads of pipes with idealized TWCs. For the quantification of the effect of slanted crack on plastic limit load, slant correction factors for calculating the plastic limit loads of pipes with slanted TWCs from pipes with idealized TWCs are newly proposed from extensive 3D FE calculations. These slant-correction factors are presented in tabulated form for practical ranges of geometry and for each set of loading conditions

  6. Probability Based Evaluation of Vehicular Bridge Load using Weigh-in-Motion Data

    OpenAIRE

    Widi Nugraha; Indra Djati Sidi

    2016-01-01

    Load and Resistance Factored Design (LRFD) method for designing bridge in Indonesia have been implemented for more than 25 years. LRFD method treating loads and strengths variables as random variables with specific safety factors for different loads and strengths variables type. The nominal loads, load factors, reduction factors, and other criteria for bridge design code can be determined to meet the reliability criteria. Statistical data of weigh-in-motion (WIM) vehicular loads measurement i...

  7. +Gz load and executive functions.

    Science.gov (United States)

    Biernacki, Marcin P; Tarnowski, Adam; Lengsfeld, Kamila; Lewkowicz, Rafał; Kowalczuk, Krzysztof; Dereń, Miroslaw

    2013-05-01

    Pilots are constantly exposed to a number of environmental factors, which include +Gz load. Physiological changes evoked by +Gz stimuli have already been well investigated in aviation medicine. However, the influence of +Gz stimulation on executive functions in pilots has not yet been thoroughly explored. There were 20 pilot cadets between the ages of 19 and 22 yr who volunteered to participate in the experiment. The subjects were divided into two groups: the G-load group, which was exposed to accelerations in the centrifuge, and the control group, which did not undergo this stimulation. Executive functions were assessed by means of the Schulte tables and the Rey-Osterrieth complex figure test. +Gz load exposure significantly improved attention switching. This relationship was valid for performance speed (M = 268.09 s in the pretest in the G-load group; M = 228.09 s in the posttest in the G-load group) and for the cumulative time of mistakes (M = 26.73 s in the pretest in the G-load group; M = 12 s in the posttest in the G-load group), whereas reproduction of visuospatial stimuli from memory deteriorated significantly under the influence of +Gz stimulation (M = 17.18 points in the posttest in the G-load group; M = 28.18 points in the posttest in the control group). These results suggest that the impact of +Gz load is not homogenous and unidirectional, since it improves attention switching but visuospatial working memory decreases under its influence. These aspects are particularly important for understanding the mechanisms responsible for maintaining situational awareness during the flight.

  8. Reliability analysis of RC containment structures under combined loads

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Kagami, S.

    1984-01-01

    This paper discusses a reliability analysis method and load combination design criteria for reinforced concrete containment structures under combined loads. The probability based reliability analysis method is briefly described. For load combination design criteria, derivations of the load factors for accidental pressure due to a design basis accident and safe shutdown earthquake (SSE) for three target limit state probabilities are presented

  9. Voltage-Sharing Converter to Supply Single-Phase Asymmetrical Four-Level Diode-Clamped Inverter With High Power Factor Loads

    DEFF Research Database (Denmark)

    Boora, Arash A.; Nami, Alireza; Zare, Firuz

    2010-01-01

    The output voltage quality of some of the single-phase multilevel inverters can be improved when their dc-link voltages are regulated asymmetrically. Symmetrical and asymmetrical multilevel diode-clamped inverters have the problem of dc-link capacitor voltage balancing, especially when power factor...... that the proposed combination of introduced multioutput dc–dc converter and single-phase ADCI is a good candidate for power conversion in residential photovoltaic (PV) utilization....

  10. electrical load survey electrical load survey and forecast

    African Journals Online (AJOL)

    eobe

    scattered nature of the area and low load factor. In this ... employment and allow decentralized production of the ... and viable concept from energy production and .... VII Yr. ×. kWh. VIII Yr. ×. kWh. IX Yr. ×. kWh. X Yr. ×. kWh. 1. Residential. 147.

  11. C.A.P. Follow up of the transients and use factors for the most loaded elements of the primary circuit

    International Nuclear Information System (INIS)

    Gaouditz, N.; Chabre, A.; Lecourtois, Y.

    1979-01-01

    The control authorities of all countries lay down increasingly stricter rules for the definition, fabrication and maintenance of nuclear capacities under pressure. In particular the operator has to ensure that the apparatus does not have to withstand stresses greater in number, intensity and rapidity than those allowed for in the project. In other words he must workout, classify and combine the various transients supported by the apparatus throughout its lifetime. The account method enables the actual transients to be classified in relation to the reference transients and their cumulated number followed periodically. This number can then be used to find the use factor which, when extrapolated to the lifetime of the element concerned, must be lower or equal to the use factor provided in the design always less than one. In point of fact, although simple in formulation, this becomes fairly complicated in application for a particular point of the capacity may be subjected to a great number of various types of stresses, each one leading to a particular damage of which the use factors, f, will be cumulated in accordance with the rules stipulated in the ASME Code, section III [fr

  12. Correlation bethealtyy ween dietary glycemic index and glycemic load and blood lipid levels in a group of women from Ahvaz

    OpenAIRE

    Farideh Shishebor; Zahra Shamekhi; Majid Karandish; Seyed Mahmood Latifi

    2011-01-01

    Background & Objectives: There are limited number of studies conducted on the correlation between Glycemic index and Glycemic load of a food program and metabolic factors such as blood lipids in Asian countries including Iran. Therefore, this study aimed at analyzing the correlation between Glycemic index and Glycemic load of Iranian food program and blood lipids. Materials & Methods: The subjects were 95 women working in Ahvaz University of Medical Sciences in the range of 20 to 55 years old...

  13. Simulation of PV/FC power hybrid system. Change of system capacity with load form factor; Taiyoko hatsuden nenryo denchi hybrid system no simulation. Fuka keijoritsu ni yoru system yoryo no henka

    Energy Technology Data Exchange (ETDEWEB)

    Sekiguchi, N.; Tani, T. [Science University of Tokyo, Tokyo (Japan)

    1997-11-25

    Study is conducted of a photovoltaic/fuel-cell hybrid system whose power storage is a hydrogen storage that uses a hydrogen absorbing alloy. In a simulation in this research, the solar cell conversion efficiency is changed from 15.0% to 21.0% and the fuel cell power conversion efficiency from 40.0% to 50.0%, and the resultant changes in the capacity and operation rate are investigated for each of the devices in the system. The findings follow. A 1.0% change in the solar cell conversion efficiency results in a 4.8kW change in the solar cell capacity and a 1.6-ton change in the hydrogen storage capacity. With a 1.0% change in the fuel cell power conversion efficiency, there is a 14.7kW change in the solar cell capacity and a 5.3-ton change in the hydrogen storage capacity. The fuel cell capacity is not dependent on the solar cell conversion efficiency or fuel cell power conversion efficiency but on the maximum load in each of the load form factors. The rate of occurrence of an operation rate of less than 30% is 54.7% both in DC/DC converter and hydrogen generator, 24.6% in fuel cells, and 16.7% in the DC/DC inverter. 7 refs., 7 figs., 1 tab.

  14. The effect of Fe, Mn, Ni and Pb Load on Soil and its enrichment factor ratios in different soil grain size fractions as an Indicator for soil pollution

    International Nuclear Information System (INIS)

    Rabie, F.H.; Abdel-Sabour, M.F.

    2000-01-01

    An industrial area north of greater Cairo was selected to investigate the impact of intensive industrial activities on soil characteristics and Fe, Mn, Ni and Pb total content. The studied area was divided to six sectors according to its source of irrigation water and/or probability of pollution. Sixteen soil profiles were dug and soil samples were taken, air dried, fractionated to different grain size fractions, then total heavy metals (Fe, Mn, Ni and Pb) were determined using ICP technique. The enrichment factor for each metal for each soil fraction/soil layer was estimated and discussed. The highest EF ratios in the clay fraction was mainly with Pb which indicated the industrial impact on the soil. In case of sand fraction, Mn was the highest always compared to other studied metals. Concerning silt fraction, a varied accumulation of Fe, Mn, and Pb was observed with soil depth and different soil profiles

  15. 1993 Pacific Northwest Loads and Resources Study.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1993-12-01

    The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

  16. Analysis of load monitoring system in hydraulic mobile cranes

    Science.gov (United States)

    Kalairassan, G.; Boopathi, M.; Mohan, Rijo Mathew

    2017-11-01

    Load moment limiters or safe load control systems or are very important in crane safety. The system detects the moment of lifting load and compares this actual moment with the rated moment. The system uses multiple sensors such as boom angle sensor, boom length sensor for telescopic booms, pressure transducers for measuring the load, anti-two block switch and roller switches. The system works both on rubber and on outriggers. The sensors measure the boom extension, boom angle and load to give as inputs to the central processing, which calculate the safe working load range for that particular configuration of the crane and compare it with the predetermined safe load. If the load exceeds the safe load, actions will be taken which will reduce the load moment, which is boom telescopic retraction and boom lifting. Anti-two block switch is used to prevent the two blocking condition. The system is calibrated and load tested for at most precision.

  17. The effects of loading history on fatigue crack growth threshold

    International Nuclear Information System (INIS)

    Ogawa, Takeshi; Tokaji, Keiro; Ochi, Satoshi; Kobayashi, Hideo.

    1987-01-01

    The effects of loading history on threshold stress intensity range (ΔK th ) were investigated in a low alloy steel SFVQ1A (A508 - 3) and a low carbon steel S10C. A single overload and multiple overloads were chosen as loading history. Crack growth and crack closure following the loading histories were measured at load ratios of 0.05 and 0.70. Threshold values were determined as a fatigue limit of preloaded specimens. The ΔK th values increased with increasing overload stress intensity factor (K h ). For a given K h value, multiple overloads produced much larger increase in ΔK th than a single overload and threshold values expressed by maximum stress intensity factor (K max,th ) were almost constant, independent of stress ratio. The results obtained were discussed in terms of crack closure behaviour, and a method was proposed to evaluate the threshold value based on plasticity-induced crack closure. (author)

  18. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D.

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially. PMID:26082709

  19. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory.

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  20. Impact of Spatial and Verbal Short-Term Memory Load on Auditory Spatial Attention Gradients.

    Science.gov (United States)

    Golob, Edward J; Winston, Jenna; Mock, Jeffrey R

    2017-01-01

    Short-term memory load can impair attentional control, but prior work shows that the extent of the effect ranges from being very general to very specific. One factor for the mixed results may be reliance on point estimates of memory load effects on attention. Here we used auditory attention gradients as an analog measure to map-out the impact of short-term memory load over space. Verbal or spatial information was maintained during an auditory spatial attention task and compared to no-load. Stimuli were presented from five virtual locations in the frontal azimuth plane, and subjects focused on the midline. Reaction times progressively increased for lateral stimuli, indicating an attention gradient. Spatial load further slowed responses at lateral locations, particularly in the left hemispace, but had little effect at midline. Verbal memory load had no (Experiment 1), or a minimal (Experiment 2) influence on reaction times. Spatial and verbal load increased switch costs between memory encoding and attention tasks relative to the no load condition. The findings show that short-term memory influences the distribution of auditory attention over space; and that the specific pattern depends on the type of information in short-term memory.

  1. Impact of Spatial and Verbal Short-Term Memory Load on Auditory Spatial Attention Gradients

    Directory of Open Access Journals (Sweden)

    Edward J. Golob

    2017-11-01

    Full Text Available Short-term memory load can impair attentional control, but prior work shows that the extent of the effect ranges from being very general to very specific. One factor for the mixed results may be reliance on point estimates of memory load effects on attention. Here we used auditory attention gradients as an analog measure to map-out the impact of short-term memory load over space. Verbal or spatial information was maintained during an auditory spatial attention task and compared to no-load. Stimuli were presented from five virtual locations in the frontal azimuth plane, and subjects focused on the midline. Reaction times progressively increased for lateral stimuli, indicating an attention gradient. Spatial load further slowed responses at lateral locations, particularly in the left hemispace, but had little effect at midline. Verbal memory load had no (Experiment 1, or a minimal (Experiment 2 influence on reaction times. Spatial and verbal load increased switch costs between memory encoding and attention tasks relative to the no load condition. The findings show that short-term memory influences the distribution of auditory attention over space; and that the specific pattern depends on the type of information in short-term memory.

  2. Brain-Derived Neurotrophic Factor Loaded PS80 PBCA Nanocarrier for In Vitro Neural Differentiation of Mouse Induced Pluripotent Stem Cells

    Directory of Open Access Journals (Sweden)

    Chiu-Yen Chung

    2017-03-01

    Full Text Available Brain derived neurotrophic factor (BDNF can induce neural differentiation in stem cells and has the potential for repair of the nervous system. In this study, a polysorbate 80-coated polybutylcyanoacrylate nanocarrier (PS80 PBCA NC was constructed to deliver plasmid DNAs (pDNAs containing BDNF gene attached to a hypoxia-responsive element (HRE-cmvBDNF. The hypoxia-sensing mechanism of BDNF expression and inductiveness of the nano-formulation on mouse induced pluripotent stem cells (iPSCs to differentiate into neurons following hypoxia was tested in vitro with immunofluorescent staining and Western blotting. The HRE-cmvBDNF appeared to adsorb onto the surface of PS80 PBCA NC, with a resultant mean diameter of 92.6 ± 1.0 nm and zeta potential of −14.1 ± 1.1 mV. HIF-1α level in iPSCs was significantly higher in hypoxia, which resulted in a 51% greater BDNF expression when transfected with PS80 PBCA NC/HRE-cmvBDNF than those without hypoxia. TrkB and phospho-Akt were also elevated which correlated with neural differentiation. The findings suggest that PS80 PBCA NC too can be endocytosed to serve as an efficient vector for genes coupled to the HRE in hypoxia-sensitive cells, and activation of the PI3/Akt pathway in iPSCs by BDNF is capable of neural lineage specification.

  3. Priority hazardous substances for the aquatic environment: critical evaluation of the emission factor method for the indirect estimate of the loads

    International Nuclear Information System (INIS)

    Azzellino, A.; Vismara, R.

    2005-01-01

    The European Water Framework Directive require to the EU Member States the knowledge of the priority hazardous pollutant contamination levels. Regional basin management plans (according to Italian laws D.Lgs 152/99 and to D.M. 367/03) generally include a review about the status of water contamination to respond to the Eu legislation prescriptions. However, since the actual monitoring activity of the water contamination is expensive and also extremely difficult in terms of analytical sensitivity, the most of these reviews has been prepared by using indirect emission coefficient estimates derived form literature. It is well known that such emission coefficients have been rarely proved fully reliable; moreover such an approach gives no information about the variability affecting the emission estimates. Aim of this work was to use the data contained into the emission EPER-INES database, european database which contains the IPPC Directive emission declarations, to define emission coefficients more reliable than literature coefficients. The presented results, even though based on a limited number of observations and referring the most only to heavy metals, confirm the scarce affidability of the emission factor method and show remarkable discrepancies (mostly under- but also over-estimations of about ten-fold) of these emission estimates from the actual emission data of the IPPC declarations. These results allow also to evaluate the not negligible variability that affects the definition of emission coefficients [it

  4. Investigating the role of free-ranging wild boar (Sus scrofa in the re-emergence of enzootic pneumonia in domestic pig herds: a pathological, prevalence and risk-factor study.

    Directory of Open Access Journals (Sweden)

    Mainity Batista Linhares

    Full Text Available Enzootic pneumonia (EP caused by Mycoplasma hyopneumoniae has a significant economic impact on domestic pig production. A control program carried out from 1999 to 2003 successfully reduced disease occurrence in domestic pigs in Switzerland, but recurrent outbreaks suggested a potential role of free-ranging wild boar (Sus scrofa as a source of re-infection. Since little is known on the epidemiology of EP in wild boar populations, our aims were: (1 to estimate the prevalence of M. hyopneumoniae infections in wild boar in Switzerland; (2 to identify risk factors for infection in wild boar; and (3 to assess whether infection in wild boar is associated with the same gross and microscopic lesions typical of EP in domestic pigs. Nasal swabs, bronchial swabs and lung samples were collected from 978 wild boar from five study areas in Switzerland between October 2011 and May 2013. Swabs were analyzed by qualitative real time PCR and a histopathological study was conducted on lung tissues. Risk factor analysis was performed using multivariable logistic regression modeling. Overall prevalence in nasal swabs was 26.2% (95% CI 23.3-29.3% but significant geographical differences were observed. Wild boar density, occurrence of EP outbreaks in domestic pigs and young age were identified as risk factors for infection. There was a significant association between infection and lesions consistent with EP in domestic pigs. We have concluded that M. hyopneumoniae is widespread in the Swiss wild boar population, that the same risk factors for infection of domestic pigs also act as risk factors for infection of wild boar, and that infected wild boar develop lesions similar to those found in domestic pigs. However, based on our data and the outbreak pattern in domestic pigs, we propose that spillover from domestic pigs to wild boar is more likely than transmission from wild boar to pigs.

  5. Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the 13.5-41.5-keV energy range

    International Nuclear Information System (INIS)

    Jonge, Martin D. de; Tran, Chanh Q.; Chantler, Christopher T.; Barnea, Zwi; Dhal, Bipin B.; Cookson, David J.; Lee, Wah-Keat; Mashayekhi, Ali

    2005-01-01

    We use the x-ray extended-range technique (XERT) [Chantler et al., Phys. Rev. A 64, 062506 (2001)] to measure the mass attenuation coefficients of molybdenum in the x-ray energy range of 13.5-41.5 keV to 0.02-0.15 % accuracy. Measurements made over an extended range of the measurement parameter space are critically examined to identify, quantify, and correct where necessary a number of experimental systematic errors. These results represent the most extensive experimental data set for molybdenum and include absolute mass attenuation coefficients in the regions of the x-ray absorption fine structure (XAFS) and x-ray-absorption near-edge structure (XANES). The imaginary component of the atomic form-factor f 2 is derived from the photoelectric absorption after subtracting calculated Rayleigh and Compton scattering cross sections from the total attenuation. Comparison of the result with tabulations of calculated photoelectric absorption coefficients indicates that differences of 1-15 % persist between the calculated and observed values

  6. Load forecasting method considering temperature effect for distribution network

    Directory of Open Access Journals (Sweden)

    Meng Xiao Fang

    2016-01-01

    Full Text Available To improve the accuracy of load forecasting, the temperature factor was introduced into the load forecasting in this paper. This paper analyzed the characteristics of power load variation, and researched the rule of the load with the temperature change. Based on the linear regression analysis, the mathematical model of load forecasting was presented with considering the temperature effect, and the steps of load forecasting were given. Used MATLAB, the temperature regression coefficient was calculated. Using the load forecasting model, the full-day load forecasting and time-sharing load forecasting were carried out. By comparing and analyzing the forecast error, the results showed that the error of time-sharing load forecasting method was small in this paper. The forecasting method is an effective method to improve the accuracy of load forecasting.

  7. Multi-Capacity Load Cell Concept

    Directory of Open Access Journals (Sweden)

    Seif. M. OSMAN

    2014-09-01

    Full Text Available Force measuring systems are usually used to calibrate force generated systems, it is not preferable to use load cells to measure forces less than 10 % of its nominal capacity. Several load cells are required to offer calibration facilities at sites to cover different ranges, this lead to difficulties in handling procedures, through the need for several carrying cases to carry this overweight in addition to the over cost of purchasing several load cells. This article concerns with introducing a new concept for designing a multi-capacity load cell as a new force standard in the field of measuring the force. This multi-capacity load cell will replace a set of load cells and reflects economically on the total cost and on easiness of handling procedures.

  8. Economic impact analysis of load forecasting

    International Nuclear Information System (INIS)

    Ranaweera, D.K.; Karady, G.G.; Farmer, R.G.

    1997-01-01

    Short term load forecasting is an essential function in electric power system operations and planning. Forecasts are needed for a variety of utility activities such as generation scheduling, scheduling of fuel purchases, maintenance scheduling and security analysis. Depending on power system characteristics, significant forecasting errors can lead to either excessively conservative scheduling or very marginal scheduling. Either can induce heavy economic penalties. This paper examines the economic impact of inaccurate load forecasts. Monte Carlo simulations were used to study the effect of different load forecasting accuracy. Investigations into the effect of improving the daily peak load forecasts, effect of different seasons of the year and effect of utilization factors are presented

  9. Using bench press load to predict upper body exercise loads in physically active individuals.

    Science.gov (United States)

    Wong, Del P; Ngo, Kwan-Lung; Tse, Michael A; Smith, Andrew W

    2013-01-01

    This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m(-2)) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p bench press load was a significant (R(2) range from 0.64 to 0.86, p Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key pointsThe bench press load was significantly correlated with the loads of the 4 assistance exercises.No significant differences were found between the actual load and the predicted load in the four equations.6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises.

  10. Wind Loads on Structures

    DEFF Research Database (Denmark)

    Dyrbye, Claes; Hansen, Svend Ole

    Wind loads have to be taken into account when designing civil engineering structures. The wind load on structures can be systematised by means of the wind load chain: wind climate (global), terrain (wind at low height), aerodynamic response (wind load to pressure), mechanical response (wind...... pressure to structural response) and design criteria. Starting with an introduction of the wind load chain, the book moves on to meteorological considerations, atmospheric boundary layer, static wind load, dynamic wind load and scaling laws used in wind-tunnel tests. The dynamic wind load covers vibrations...... induced by wind turbulence, vortex shedding, flutter and galloping. The book gives a comprehensive treatment of wind effects on structures and it will be useful for consulting engineers designing wind-sensitive structures. It will also be valuable for students of civil engineering as textbook...

  11. Carbohydrate-Loading Diet

    Science.gov (United States)

    ... Grape juice (12 ounces) 55 225 Lunch Milk, chocolate, reduced fat (12 ounces) 45 285 4 slices ... usual during carbohydrate loading to get the same benefits as a man does. Despite carbohydrate loading, you ...

  12. Autonomous Propellant Loading Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The AES Autonomous Propellant Loading (APL) project consists of three activities. The first is to develop software that will automatically control loading of...

  13. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  14. Diffusion Indexes with Sparse Loadings

    DEFF Research Database (Denmark)

    Kristensen, Johannes Tang

    The use of large-dimensional factor models in forecasting has received much attention in the literature with the consensus being that improvements on forecasts can be achieved when comparing with standard models. However, recent contributions in the literature have demonstrated that care needs...... to the problem by using the LASSO as a variable selection method to choose between the possible variables and thus obtain sparse loadings from which factors or diffusion indexes can be formed. This allows us to build a more parsimonious factor model which is better suited for forecasting compared...... it to be an important alternative to PC....

  15. Limit loads in nozzles

    International Nuclear Information System (INIS)

    Zouain, N.

    1983-01-01

    The static method for the evaluation of the limit loads of a perfectly elasto-plastic structure is presented. Using the static theorem of Limit Analysis and the Finite Element Method, a lower bound for the colapso load can be obtained through a linear programming problem. This formulation if then applied to symmetrically loaded shells of revolution and some numerical results of limit loads in nozzles are also presented. (Author) [pt

  16. Friction and anchorage loading revisited.

    Science.gov (United States)

    Dholakia, Kartik D

    2012-01-01

    Contemporary concepts of sliding mechanics explain that friction is inevitable. To overcome this frictional resistance, excess force is required to retract the tooth along the archwire (ie, individual retraction of canines, en masse retraction of anterior teeth), in addition to the amount of force required for tooth movement. The anterior tooth retraction force, in addition to excess force (to overcome friction), produces reciprocal protraction force on molars, thereby leading to increased anchorage loading. However, this traditional concept was challenged in recent literature, which was based on the finite element model, but did not bear correlation to the clinical scenario. This article will reinforce the fact that clinically, friction increases anchorage loading in all three planes of space, considering the fact that tooth movement is a quasistatic process rather than a purely continuous or static one, and that conventional ways of determining the effects of static or dynamic friction on anchorage load cannot be applied to clinical situations (which consist of anatomical resistance units and a complex muscular force system). The article does not aim to quantify friction and its effect on the amount of anchorage load. Rather, a new perspective regarding the role of various additional factors (which is not explained by contemporary concept) that may influence friction and anchorage loading is provided..

  17. Study of the /sup 58/Ni, /sup 90/Zr and /sup 208/Pb(p,d) reactions at 121 MeV. [DWBA, angular distributions, spectroscopic factors, finite range calculations

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R E; Kraushaar, J J; Shepard, J R [Colorado Univ., Boulder (USA). Nuclear Physics Lab.; Comfort, J R [Indiana Univ., Bloomington (USA). Dept. of Physics

    1978-01-01

    The (p,d) reaction has been studied on /sup 58/Ni, /sup 90/Zr and /sup 208/Pb at 121 MeV in order to test the applicability of the usual DWBA methods to higher energy data. The calculations describe the angular distribution for the strongly excited low-lying states reasonably well when adiabatic-deuteron optical potentials are used. Some discrepancies in shape persist, however, and some values of the spectroscopic factors differ from lower energy data in spite of many variations in the calculations. By use of exact finite-range calculations a value of D/sup 2//sub 0/ = 1.23 x 10/sup 4/ MeV/sup 2/.fm/sup 3/ was found for use at 121 MeV. Deuteron D-state contributions were negligible at forward angles and two-step contributions do not appear more significant than for data at lower energy.

  18. Therapy by electromagnetic wave of millimeter energy range (EFH-therapy, MRT, IWT). Scientific and practical materials on the use of physical factors in clinical and health resort practice

    International Nuclear Information System (INIS)

    Samosyuk, I.Z.; Chukhraev, N.V.; Shimkov, G.E.; Bitson, A.V.

    1999-01-01

    EHF-therapy method is a principally new method of treatment which is based on the peculiarities in perception by human organism the magnetic radiation of millimeter energy range. Practical use of this method has shown its high therapeutic efficiency at influencing on acupuncture points. This monography is completely devoted to description of EHF-therapy effects on acupuncture points with account of the Chinese reflexotherapy. Apparats of 'MIT' and 'Eleknronika-EHF' series do not provoke any damages in biological structures and refer to the safe class. The proposed scientific and practical materials on the use of physical factors in clinical and health resort practice are edited in addition to the previous monograph under the same title. These materials are of use for physicians of different specializations and listeners of medical advanced courses

  19. Spatial analysis of instream nitrogen loads and factors controlling nitrogen delivery to streams in the southeastern United States using spatially referenced regression on watershed attributes (SPARROW) and regional classification frameworks

    Science.gov (United States)

    Hoos, Anne B.; McMahon, Gerard

    2009-01-01

    Understanding how nitrogen transport across the landscape varies with landscape characteristics is important for developing sound nitrogen management policies. We used a spatially referenced regression analysis (SPARROW) to examine landscape characteristics influencing delivery of nitrogen from sources in a watershed to stream channels. Modelled landscape delivery ratio varies widely (by a factor of 4) among watersheds in the southeastern United States—higher in the western part (Tennessee, Alabama, and Mississippi) than in the eastern part, and the average value for the region is lower compared to other parts of the nation. When we model landscape delivery ratio as a continuous function of local-scale landscape characteristics, we estimate a spatial pattern that varies as a function of soil and climate characteristics but exhibits spatial structure in residuals (observed load minus predicted load). The spatial pattern of modelled landscape delivery ratio and the spatial pattern of residuals coincide spatially with Level III ecoregions and also with hydrologic landscape regions. Subsequent incorporation into the model of these frameworks as regional scale variables improves estimation of landscape delivery ratio, evidenced by reduced spatial bias in residuals, and suggests that cross-scale processes affect nitrogen attenuation on the landscape. The model-fitted coefficient values are logically consistent with the hypothesis that broad-scale classifications of hydrologic response help to explain differential rates of nitrogen attenuation, controlling for local-scale landscape characteristics. Negative model coefficients for hydrologic landscape regions where the primary flow path is shallow ground water suggest that a lower fraction of nitrogen mass will be delivered to streams; this relation is reversed for regions where the primary flow path is overland flow.

  20. Power loading on the first wall during disruptions in TFTR

    International Nuclear Information System (INIS)

    Janos, A.; Fredrickson, E.D.; McGuire, K.M.; Nagayama, Y.; Owens, D.K.; Wilfrid, E.

    1992-01-01

    Heating of the first wall of TFTR due to disruptions is investigated experimentally using an extensive array of thermocouples. By comparing results from discharges with and without disruptions, we extract effects due to the disruption alone. Disruptions preferentially heat the same areas which are heated during discharges without disruptions. Hot areas are inward protrusions or regions unshielded by neighboring areas. Peaking factors in the toroidal direction, defined as peak temperature divided by average toroidal temperature, as a function of poloidal angle, are calculated. For nondisruptive discharges, the peaking factor varies between 2 and 4. For the disruptive portion of a discharge only, the peaking factor near the midplane, where most of the energy is deposited, ranges from 3 to 5. Further away from the midplane, the peaking factor can reach 28, although the heat load is less in that region. (orig.)

  1. Tonopah Test Range - Index

    Science.gov (United States)

    Capabilities Test Operations Center Test Director Range Control Track Control Communications Tracking Radars Photos Header Facebook Twitter YouTube Flickr RSS Tonopah Test Range Top TTR_TOC Tonopah is the testing range of choice for all national security missions. Tonopah Test Range (TTR) provides research and

  2. Spatial electric load forecasting

    CERN Document Server

    Willis, H Lee

    2002-01-01

    Spatial Electric Load Forecasting Consumer Demand for Power and ReliabilityCoincidence and Load BehaviorLoad Curve and End-Use ModelingWeather and Electric LoadWeather Design Criteria and Forecast NormalizationSpatial Load Growth BehaviorSpatial Forecast Accuracy and Error MeasuresTrending MethodsSimulation Method: Basic ConceptsA Detailed Look at the Simulation MethodBasics of Computerized SimulationAnalytical Building Blocks for Spatial SimulationAdvanced Elements of Computerized SimulationHybrid Trending-Simulation MethodsAdvanced

  3. Cognitive Load and Cooperation

    DEFF Research Database (Denmark)

    Døssing, Felix Sebastian; Piovesan, Marco; Wengström, Erik Roland

    2017-01-01

    We study the effect of intuitive and reflective processes on cooperation using cognitive load. Compared with time constraint, which has been used in the previous literature, cognitive load is a more direct way to block reflective processes, and thus a more suitable way to study the link between...... intuition and cooperation. Using a repeated public goods game, we study the effect of different levels of cognitive load on contributions. We show that a higher cognitive load increases the initial level of cooperation. In particular, subjects are significantly less likely to fully free ride under high...... cognitive load....

  4. Probabilistic model of bridge vehicle loads in port area based on in-situ load testing

    Science.gov (United States)

    Deng, Ming; Wang, Lei; Zhang, Jianren; Wang, Rei; Yan, Yanhong

    2017-11-01

    Vehicle load is an important factor affecting the safety and usability of bridges. An statistical analysis is carried out in this paper to investigate the vehicle load data of Tianjin Haibin highway in Tianjin port of China, which are collected by the Weigh-in- Motion (WIM) system. Following this, the effect of the vehicle load on test bridge is calculated, and then compared with the calculation result according to HL-93(AASHTO LRFD). Results show that the overall vehicle load follows a distribution with a weighted sum of four normal distributions. The maximum vehicle load during the design reference period follows a type I extremum distribution. The vehicle load effect also follows a weighted sum of four normal distributions, and the standard value of the vehicle load is recommended as 1.8 times that of the calculated value according to HL-93.

  5. The Factors of Soldier’s Load

    Science.gov (United States)

    1994-06-03

    turtles . My ruck weighed 120 pounds. American Airborne Soldier Grenada, 1983 One of the tenets of Army doctrine in Field Manual 100-5 QIp.r.aition•. is...from a lack of the appropriate physical conditioning in some units; and the more nebulous problem of insufficient logistical challenges built into

  6. The Statistical Properties of Host Load

    Directory of Open Access Journals (Sweden)

    Peter A. Dinda

    1999-01-01

    Full Text Available Understanding how host load changes over time is instrumental in predicting the execution time of tasks or jobs, such as in dynamic load balancing and distributed soft real‐time systems. To improve this understanding, we collected week‐long, 1 Hz resolution traces of the Digital Unix 5 second exponential load average on over 35 different machines including production and research cluster machines, compute servers, and desktop workstations. Separate sets of traces were collected at two different times of the year. The traces capture all of the dynamic load information available to user‐level programs on these machines. We present a detailed statistical analysis of these traces here, including summary statistics, distributions, and time series analysis results. Two significant new results are that load is self‐similar and that it displays epochal behavior. All of the traces exhibit a high degree of self‐similarity with Hurst parameters ranging from 0.73 to 0.99, strongly biased toward the top of that range. The traces also display epochal behavior in that the local frequency content of the load signal remains quite stable for long periods of time (150–450 s mean and changes abruptly at epoch boundaries. Despite these complex behaviors, we have found that relatively simple linear models are sufficient for short‐range host load prediction.

  7. The DEMO wall load challenge

    Czech Academy of Sciences Publication Activity Database

    Wenninger, R.; Albanese, R.; Ambrosino, R.; Arbeiter, F.; Aubert, J.; Bachmann, C.; Barbato, L.; Barrett, T.; Beckers, M.; Biel, W.; Boccaccini, L.; Carralero, D.; Coster, D.; Eich, T.; Fasoli, A.; Federici, G.; Firdaouss, M.; Graves, J.; Horáček, Jan; Kovari, M.; Lanthaler, S.; Loschiavo, V.; Lowry, C.; Lux, H.; Maddaluno, G.; Maviglia, F.; Mitteau, R.; Neu, R.; Pfefferle, D.; Schmid, K.; Siccinio, M.; Sieglin, B.; Silva, C.; Snicker, A.; Subba, F.; Varje, J.; Zohm, H.

    2017-01-01

    Roč. 57, č. 4 (2017), č. článku 046002. ISSN 0029-5515 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : DEMO * power loads * first wall Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.307, year: 2016 http://iopscience.iop.org/article/10.1088/1741-4326/aa4fb4

  8. A Beacon Transmission Power Control Algorithm Based on Wireless Channel Load Forecasting in VANETs.

    Science.gov (United States)

    Mo, Yuanfu; Yu, Dexin; Song, Jun; Zheng, Kun; Guo, Yajuan

    2015-01-01

    In a vehicular ad hoc network (VANET), the periodic exchange of single-hop status information broadcasts (beacon frames) produces channel loading, which causes channel congestion and induces information conflict problems. To guarantee fairness in beacon transmissions from each node and maximum network connectivity, adjustment of the beacon transmission power is an effective method for reducing and preventing channel congestion. In this study, the primary factors that influence wireless channel loading are selected to construct the KF-BCLF, which is a channel load forecasting algorithm based on a recursive Kalman filter and employs multiple regression equation. By pre-adjusting the transmission power based on the forecasted channel load, the channel load was kept within a predefined range; therefore, channel congestion was prevented. Based on this method, the CLF-BTPC, which is a transmission power control algorithm, is proposed. To verify KF-BCLF algorithm, a traffic survey method that involved the collection of floating car data along a major traffic road in Changchun City is employed. By comparing this forecast with the measured channel loads, the proposed KF-BCLF algorithm was proven to be effective. In addition, the CLF-BTPC algorithm is verified by simulating a section of eight-lane highway and a signal-controlled urban intersection. The results of the two verification process indicate that this distributed CLF-BTPC algorithm can effectively control channel load, prevent channel congestion, and enhance the stability and robustness of wireless beacon transmission in a vehicular network.

  9. A Beacon Transmission Power Control Algorithm Based on Wireless Channel Load Forecasting in VANETs.

    Directory of Open Access Journals (Sweden)

    Yuanfu Mo

    Full Text Available In a vehicular ad hoc network (VANET, the periodic exchange of single-hop status information broadcasts (beacon frames produces channel loading, which causes channel congestion and induces information conflict problems. To guarantee fairness in beacon transmissions from each node and maximum network connectivity, adjustment of the beacon transmission power is an effective method for reducing and preventing channel congestion. In this study, the primary factors that influence wireless channel loading are selected to construct the KF-BCLF, which is a channel load forecasting algorithm based on a recursive Kalman filter and employs multiple regression equation. By pre-adjusting the transmission power based on the forecasted channel load, the channel load was kept within a predefined range; therefore, channel congestion was prevented. Based on this method, the CLF-BTPC, which is a transmission power control algorithm, is proposed. To verify KF-BCLF algorithm, a traffic survey method that involved the collection of floating car data along a major traffic road in Changchun City is employed. By comparing this forecast with the measured channel loads, the proposed KF-BCLF algorithm was proven to be effective. In addition, the CLF-BTPC algorithm is verified by simulating a section of eight-lane highway and a signal-controlled urban intersection. The results of the two verification process indicate that this distributed CLF-BTPC algorithm can effectively control channel load, prevent channel congestion, and enhance the stability and robustness of wireless beacon transmission in a vehicular network.

  10. Strength and behavior in shear of reinforced concrete deep beams under dynamic loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Adhikary, Satadru Das [School of Civil and Environmental Engineering, Nanyang Technological University, 639798 (Singapore); Li, Bing, E-mail: cbli@ntu.edu.sg [School of Civil and Environmental Engineering, Nanyang Technological University, 639798 (Singapore); Fujikake, Kazunori [Department of Civil and Environmental Engineering, National Defense Academy, Yokosuka 239 8686 (Japan)

    2013-06-15

    Highlights: ► Effects of wider range of loading rates on dynamic shear behavior of RC deep beams. ► Experimental investigation of RC deep beam with and without shear reinforcements. ► Verification of experimental results with truss model and FE simulation results. ► Empirical equations are proposed to predict the dynamic increase factor of maximum resistance. -- Abstract: Research on reinforced concrete (RC) deep beams has seen considerable headway over the past three decades; however, information on the dynamic shear strength and behavior of RC deep beams under varying rates of loads remains limited. This paper describes the experimental results of 24 RC deep beams with and without shear reinforcements under varying rates of concentrated loading. Results obtained serve as useful data on shear resistance, failure patterns and strain rates corresponding to varying loading rates. An analytical truss model approach proves its efficacy in predicting the dynamic shear resistance under varying loading rates. Furthermore, three-dimensional nonlinear finite element (FE) model is described and the simulation results are verified with the experimental results. A parametric study is then conducted to investigate the influence of longitudinal reinforcement ratio, transverse reinforcement ratio and shear span to effective depth ratio on shear behavior. Subsequently, two empirical equations were proposed by integrating the various parameters to assess the dynamic increase factor (DIF) of maximum resistance under varying rates of concentrated loading.

  11. Neural networks approach to forecast several hour ahead electricity prices and loads in deregulated market

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Paras; Senjyu, Tomonobu [Department of Electrical and Electronics, University of the Ryukyus, 1 Senbaru, Nagakami Nishihara, Okinawa 903-0213 (Japan); Funabashi, Toshihisa [Meidensha Corporation, Tokyo 103-8515 (Japan)

    2006-09-15

    In daily power markets, forecasting electricity prices and loads are the most essential task and the basis for any decision making. An approach to predict the market behaviors is to use the historical prices, loads and other required information to forecast the future prices and loads. This paper introduces an approach for several hour ahead (1-6h) electricity price and load forecasting using an artificial intelligence method, such as a neural network model, which uses publicly available data from the NEMMCO web site to forecast electricity prices and loads for the Victorian electricity market. An approach of selection of similar days is proposed according to which the load and price curves are forecasted by using the information of the days being similar to that of the forecast day. A Euclidean norm with weighted factors is used for the selection of the similar days. Two different ANN models, one for one to six hour ahead load forecasting and another for one to six hour ahead price forecasting have been proposed. The MAPE (mean absolute percentage error) results show a clear increasing trend with the increase in hour ahead load and price forecasting. The sample average of MAPEs for one hour ahead price forecasts is 9.75%. This figure increases to only 20.03% for six hour ahead predictions. Similarly, the one to six hour ahead load forecast errors (MAPE) range from 0.56% to 1.30% only. MAPE results show that several hour ahead electricity prices and loads in the deregulated Victorian market can be forecasted with reasonable accuracy. (author)

  12. Neural networks approach to forecast several hour ahead electricity prices and loads in deregulated market

    International Nuclear Information System (INIS)

    Mandal, Paras; Senjyu, Tomonobu; Funabashi, Toshihisa

    2006-01-01

    In daily power markets, forecasting electricity prices and loads are the most essential task and the basis for any decision making. An approach to predict the market behaviors is to use the historical prices, loads and other required information to forecast the future prices and loads. This paper introduces an approach for several hour ahead (1-6 h) electricity price and load forecasting using an artificial intelligence method, such as a neural network model, which uses publicly available data from the NEMMCO web site to forecast electricity prices and loads for the Victorian electricity market. An approach of selection of similar days is proposed according to which the load and price curves are forecasted by using the information of the days being similar to that of the forecast day. A Euclidean norm with weighted factors is used for the selection of the similar days. Two different ANN models, one for one to six hour ahead load forecasting and another for one to six hour ahead price forecasting have been proposed. The MAPE (mean absolute percentage error) results show a clear increasing trend with the increase in hour ahead load and price forecasting. The sample average of MAPEs for one hour ahead price forecasts is 9.75%. This figure increases to only 20.03% for six hour ahead predictions. Similarly, the one to six hour ahead load forecast errors (MAPE) range from 0.56% to 1.30% only. MAPE results show that several hour ahead electricity prices and loads in the deregulated Victorian market can be forecasted with reasonable accuracy

  13. Optimisation of load control

    International Nuclear Information System (INIS)

    Koponen, P.

    1998-01-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  14. Optimisation of load control

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland)

    1998-08-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  15. Comparison of Deterministic and Probabilistic Radial Distribution Systems Load Flow

    Science.gov (United States)

    Gupta, Atma Ram; Kumar, Ashwani

    2017-12-01

    Distribution system network today is facing the challenge of meeting increased load demands from the industrial, commercial and residential sectors. The pattern of load is highly dependent on consumer behavior and temporal factors such as season of the year, day of the week or time of the day. For deterministic radial distribution load flow studies load is taken as constant. But, load varies continually with a high degree of uncertainty. So, there is a need to model probable realistic load. Monte-Carlo Simulation is used to model the probable realistic load by generating random values of active and reactive power load from the mean and standard deviation of the load and for solving a Deterministic Radial Load Flow with these values. The probabilistic solution is reconstructed from deterministic data obtained for each simulation. The main contribution of the work is: Finding impact of probable realistic ZIP load modeling on balanced radial distribution load flow. Finding impact of probable realistic ZIP load modeling on unbalanced radial distribution load flow. Compare the voltage profile and losses with probable realistic ZIP load modeling for balanced and unbalanced radial distribution load flow.

  16. Shakedown and ratchetting below the creep range

    International Nuclear Information System (INIS)

    Ponter, A.R.S.

    1983-01-01

    The report reviews current understanding of the behaviour of structure subject to variable mechanical and thermal loading below the creep range through a comparison of theoretical solutions and experimental studies. The particular characteristics of the austenitic stainless steels are emphasized in components subject to moderate primary loads and large thermal loads. The review shows that a clear classification of types of thermal loading is required in design. Two main classes, termed category A and B, exist which arise not from the magnitude of the thermal stresses but their extent through the material volume of the structure. In category A situations, the Bree plate problem being the prime example, the maximum thermal stresses occur over a volume of the structure which does not contain a mechanism of failure. As a result very large thermal stresses may be withstood without ratchetting occurring for sufficiently small mechanical loads. For category B situations, the maximum thermal stress occur within a volume of material which contains a mechanism of deformation. In such cases, the capacity of the structure to withstand thermal loading is limited by a variation of the maximum thermal stress at a material point of 2σsub(γ) where σsub(γ) is a suitably defined yield stress. This situation seems to be the most typical problem of the Liquid Metal Fast Reactor and the ''3Sm'' limit in the ASME III code restriction on secondary stress cannot be exceeded if ratchetting is to be prevented

  17. Finite element limit loads for non-idealized through-wall cracks in thick-walled pipe

    International Nuclear Information System (INIS)

    Shim, Do-Jun; Han, Tae-Song; Huh, Nam-Su

    2013-01-01

    Highlights: • The lower bound bulging factor of thin-walled pipe can be used for thick-walled pipe. • The limit loads are proposed for thick-walled, transition through-wall cracked pipe. • The correction factors are proposed for estimating limit loads of transition cracks. • The limit loads of short transition cracks are similar to those of idealized cracks. - Abstract: The present paper provides plastic limit loads for non-idealized through-wall cracks in thick-walled pipe. These solutions are based on detailed 3-dimensional finite element (FE) analyses which can be used for structural integrity assessment of nuclear piping. To cover a practical range of interest, the geometric variables and loading conditions affecting the plastic limit loads of thick-walled pipe with non-idealized through-wall cracks were systematically varied. In terms of crack orientation, both circumferential and axial through-wall cracks were considered. As for loading conditions, axial tension, global bending, and internal pressure were considered for circumferential cracks, whereas only internal pressure was considered for axial cracks. Furthermore, the values of geometric factor representing shape characteristics of non-idealized through-wall cracks were also systematically varied. In order to provide confidence in the present FE analyses results, plastic limit loads of un-cracked, thick-walled pipe resulting from the present FE analyses were compared with the theoretical solutions. Finally, correction factors to the idealized through-wall crack solutions were developed to determine the plastic limit loads of non-idealized through-wall cracks in thick-walled pipe

  18. Simulation of Stochastic Loads for Fatigue Experiments

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Brincker, Rune

    1989-01-01

    process by a Markov process. Two different spectra from two tubular joints in an offshore structure (one narrow banded and one wide banded) are considered in an example. The results show that the simple direct method is quite efficient and results in a simulation speed of about 3000 load cycles per second......A simple direct simulation method for stochastic fatigue-load generation is described in this paper. The simulation method is based on the assumption that only the peaks of the load process significantly affect the fatigue life. The method requires the conditional distribution functions of load...... ranges given the last peak values. Analytical estimates of these distribution functions are presented in the paper and compared with estimates based on a more accurate simulation method. In the more accurate simulation method samples at equidistant times are generated by approximating the stochastic load...

  19. Simulation of Stochastic Loads for Fatigue Experiments

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Brincker, Rune

    process by a Markov process. Two different spectra from two tubular joints in an offshore structure (one narrow banded and one wide banded) are considered in an example. The results show that the simple direct method is quite efficient and is results in a simulation speed at about 3000 load cycles per......A simple direct simulation method for stochastic fatigue load generation is described in this paper. The simulation method is based on the assumption that only the peaks of the load process significantly affect the fatigue life. The method requires the conditional distribution functions of load...... ranges given the last peak values. Analytical estimates of these distribution functions are presented in the paper and compared with estimates based on a more accurate simulation method. In the more accurate simulation method samples at equidistant times are generated by approximating the stochastic load...

  20. Confirmatory Analysis of Simultaneous, Sequential, and Achievement Factors on the K-ABC at 11 Age Levels Ranging from 2 1/2 to 12 1/2 years.

    Science.gov (United States)

    Willson, Victor L.; And Others

    1985-01-01

    Presents results of confirmatory factor analysis of the Kaufman Assessment Battery for children which is based on the underlying theoretical model of sequential, simultaneous, and achievement factors. Found support for the two-factor, simultaneous and sequential processing model. (MCF)

  1. Optimization of Nanowire-Resistance Load Logic Inverter.

    Science.gov (United States)

    Hashim, Yasir; Sidek, Othman

    2015-09-01

    This study is the first to demonstrate characteristics optimization of nanowire resistance load inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. Results indicate that optimization depends on resistance value. Increasing of load resistor tends to increasing in noise margins until saturation point, increasing load resistor after this point will not improve noise margins significantly.

  2. Processing Capacity under Perceptual and Cognitive Load: A Closer Look at Load Theory

    Science.gov (United States)

    Fitousi, Daniel; Wenger, Michael J.

    2011-01-01

    Variations in perceptual and cognitive demands (load) play a major role in determining the efficiency of selective attention. According to load theory (Lavie, Hirst, Fockert, & Viding, 2004) these factors (a) improve or hamper selectivity by altering the way resources (e.g., processing capacity) are allocated, and (b) tap resources rather than…

  3. Concentrated loads on concrete

    DEFF Research Database (Denmark)

    Lorenzen, Karen Grøndahl; Nielsen, Mogens Peter

    1997-01-01

    This report deals with concentrated loads on concrete.A new upper bound solution in the axisymmetrical case of a point load in the center of the end face of a cylinder is developed.Based on previous work dealing with failure mechanisms and upper bound solutions, new approximate formulas are devel......This report deals with concentrated loads on concrete.A new upper bound solution in the axisymmetrical case of a point load in the center of the end face of a cylinder is developed.Based on previous work dealing with failure mechanisms and upper bound solutions, new approximate formulas...

  4. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  5. Load regulating expansion fixture

    International Nuclear Information System (INIS)

    Wagner, L.M.; Strum, M.J.

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located there between. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig

  6. Laterally loaded masonry

    DEFF Research Database (Denmark)

    Raun Gottfredsen, F.

    In this thesis results from experiments on mortar joints and masonry as well as methods of calculation of strength and deformation of laterally loaded masonry are presented. The strength and deformation capacity of mortar joints have been determined from experiments involving a constant compressive...... stress and increasing shear. The results show a transition to pure friction as the cohesion is gradually destroyed. An interface model of a mortar joint that can take into account this aspect has been developed. Laterally loaded masonry panels have also been tested and it is found to be characteristic...... that laterally loaded masonry exhibits a non-linear load-displacement behaviour with some ductility....

  7. Electrical load modeling

    Energy Technology Data Exchange (ETDEWEB)

    Valgas, Helio Moreira; Pinto, Roberto del Giudice R.; Franca, Carlos [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Lambert-Torres, Germano; Silva, Alexandre P. Alves da; Pires, Robson Celso; Costa, Junior, Roberto Affonso [Escola Federal de Engenharia de Itajuba, MG (Brazil)

    1994-12-31

    Accurate dynamic load models allow more precise calculations of power system controls and stability limits, which are critical mainly in the operation planning of power systems. This paper describes the development of a computer program (software) for static and dynamic load model studies using the measurement approach for the CEMIG system. Two dynamic load model structures are developed and tested. A procedure for applying a set of measured data from an on-line transient recording system to develop load models is described. (author) 6 refs., 17 figs.

  8. Locomotor loading mechanics in the hindlimbs of tegu lizards (Tupinambis merianae): comparative and evolutionary implications.

    Science.gov (United States)

    Sheffield, K Megan; Butcher, Michael T; Shugart, S Katherine; Gander, Jennifer C; Blob, Richard W

    2011-08-01

    Skeletal elements are usually able to withstand several times their usual load before they yield, and this ratio is known as the bone's safety factor. Limited studies on amphibians and non-avian reptiles have shown that they have much higher limb bone safety factors than birds and mammals. It has been hypothesized that this difference is related to the difference in posture between upright birds and mammals and sprawling ectotherms; however, limb bone loading data from a wider range of sprawling species are needed in order to determine whether the higher safety factors seen in amphibians and non-avian reptiles are ancestral or derived conditions. Tegus (family Teiidae) are an ideal lineage with which to expand sampling of limb bone loading mechanics for sprawling taxa, particularly for lizards, because they are from a different clade than previously sampled iguanas and exhibit different foraging and locomotor habits (actively foraging carnivore versus burst-activity herbivore). We evaluated the mechanics of locomotor loading for the femur of the Argentine black and white tegu (Tupinambus merianae) using three-dimensional measurements of the ground reaction force and hindlimb kinematics, in vivo bone strains and femoral mechanical properties. Peak bending stresses experienced by the femur were low (tensile: 10.4 ± 1.1 MPa; compressive: -17.4 ± 0.9 MPa) and comparable to those in other reptiles, with moderate shear stresses and strains also present. Analyses of peak femoral stresses and strains led to estimated safety factor ranges of 8.8-18.6 in bending and 7.8-17.5 in torsion, both substantially higher than typical for birds and mammals but similar to other sprawling tetrapods. These results broaden the range of reptilian and amphibian taxa in which high femoral safety factors have been evaluated and further indicate a trend for the independent evolution of lower limb bone safety factors in endothermic taxa.

  9. Compressive laser ranging.

    Science.gov (United States)

    Babbitt, Wm Randall; Barber, Zeb W; Renner, Christoffer

    2011-12-15

    Compressive sampling has been previously proposed as a technique for sampling radar returns and determining sparse range profiles with a reduced number of measurements compared to conventional techniques. By employing modulation on both transmission and reception, compressive sensing in ranging is extended to the direct measurement of range profiles without intermediate measurement of the return waveform. This compressive ranging approach enables the use of pseudorandom binary transmit waveforms and return modulation, along with low-bandwidth optical detectors to yield high-resolution ranging information. A proof-of-concept experiment is presented. With currently available compact, off-the-shelf electronics and photonics, such as high data rate binary pattern generators and high-bandwidth digital optical modulators, compressive laser ranging can readily achieve subcentimeter resolution in a compact, lightweight package.

  10. Laterally Loaded Partially Prestressed Concrete Piles

    Science.gov (United States)

    1989-09-01

    of an extensive test program onl laterali y ioadeu. partially pr- estressed concrete fender piles. The study Included service load range as well ats...12,000-psi design strength). Configura- tion G utilized 14 r:- estress strand, in an unsymmetric pattern. To provide a uniform concrete prestress of 540...sudden loss in load carrying capacity directly related to the loss of concrete area. The compression concrete fractured longitudinally and along the

  11. Dryden Aeronautical Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — Recently redesignated to honor Dr. Hugh L. Dryden, NASA's Dryden Aeronautical Test Range (DATR) supports aerospace flight research and technology integration, space...

  12. Compact Antenna Range

    Data.gov (United States)

    Federal Laboratory Consortium — Facility consists of a folded compact antenna range including a computer controlled three axis position table, parabolic reflector and RF sources for the measurement...

  13. Is Beak Morphology in Darwin's Finches Tuned to Loading Demands?

    Directory of Open Access Journals (Sweden)

    Joris Soons

    Full Text Available One of nature's premier illustrations of adaptive evolution concerns the tight correspondence in birds between beak morphology and feeding behavior. In seed-crushing birds, beaks have been suggested to evolve at least in part to avoid fracture. Yet, we know little about mechanical relationships between beak shape, stress dissipation, and fracture avoidance. This study tests these relationships for Darwin's finches, a clade of birds renowned for their diversity in beak form and function. We obtained anatomical data from micro-CT scans and dissections, which in turn informed the construction of finite element models of the bony beak and rhamphotheca. Our models offer two new insights. First, engineering safety factors are found to range between 1 and 2.5 under natural loading conditions, with the lowest safety factors being observed in species with the highest bite forces. Second, size-scaled finite element (FE models reveal a correspondence between inferred beak loading profiles and observed feeding strategies (e.g. edge-crushing versus tip-biting, with safety factors decreasing for base-crushers biting at the beak tip. Additionally, we identify significant correlations between safety factors, keratin thickness at bite locations, and beak aspect ratio (depth versus length. These lines of evidence together suggest that beak shape indeed evolves to resist feeding forces.

  14. Load Balancing in Hypergraphs

    Science.gov (United States)

    Delgosha, Payam; Anantharam, Venkat

    2018-03-01

    Consider a simple locally finite hypergraph on a countable vertex set, where each edge represents one unit of load which should be distributed among the vertices defining the edge. An allocation of load is called balanced if load cannot be moved from a vertex to another that is carrying less load. We analyze the properties of balanced allocations of load. We extend the concept of balancedness from finite hypergraphs to their local weak limits in the sense of Benjamini and Schramm (Electron J Probab 6(23):13, 2001) and Aldous and Steele (in: Probability on discrete structures. Springer, Berlin, pp 1-72, 2004). To do this, we define a notion of unimodularity for hypergraphs which could be considered an extension of unimodularity in graphs. We give a variational formula for the balanced load distribution and, in particular, we characterize it in the special case of unimodular hypergraph Galton-Watson processes. Moreover, we prove the convergence of the maximum load under some conditions. Our work is an extension to hypergraphs of Anantharam and Salez (Ann Appl Probab 26(1):305-327, 2016), which considered load balancing in graphs, and is aimed at more comprehensively resolving conjectures of Hajek (IEEE Trans Inf Theory 36(6):1398-1414, 1990).

  15. Load Induced Blindness

    Science.gov (United States)

    Macdonald, James S. P.; Lavie, Nilli

    2008-01-01

    Although the perceptual load theory of attention has stimulated a great deal of research, evidence for the role of perceptual load in determining perception has typically relied on indirect measures that infer perception from distractor effects on reaction times or neural activity (see N. Lavie, 2005, for a review). Here we varied the level of…

  16. Load event: Aircraft crash

    International Nuclear Information System (INIS)

    Fritsch, H.

    1985-01-01

    The bibliography includes 48 quotations, up to the year 1983, on the following issues: Experiments and computational methods. Design load for the dimensioning of reinforced concrete buildings and components with respect to the dynamic load in the event of an aircraft crash. (orig./HP) [de

  17. Maximum allowable load on wheeled mobile manipulators

    International Nuclear Information System (INIS)

    Habibnejad Korayem, M.; Ghariblu, H.

    2003-01-01

    This paper develops a computational technique for finding the maximum allowable load of mobile manipulator during a given trajectory. The maximum allowable loads which can be achieved by a mobile manipulator during a given trajectory are limited by the number of factors; probably the dynamic properties of mobile base and mounted manipulator, their actuator limitations and additional constraints applied to resolving the redundancy are the most important factors. To resolve extra D.O.F introduced by the base mobility, additional constraint functions are proposed directly in the task space of mobile manipulator. Finally, in two numerical examples involving a two-link planar manipulator mounted on a differentially driven mobile base, application of the method to determining maximum allowable load is verified. The simulation results demonstrates the maximum allowable load on a desired trajectory has not a unique value and directly depends on the additional constraint functions which applies to resolve the motion redundancy

  18. Critical traffic loading for the design of prestressed concrete bridge

    International Nuclear Information System (INIS)

    Hassan, M.I.U.

    2009-01-01

    A study has been carried out to determine critical traffic loadings for the design of bridge superstructures. The prestressed concrete girder bridge already constructed in Lahore is selected for the analysis as an example. Standard traffic loadings according to AASHTO (American Association of State Highway and Transportation Officials) and Pakistan Highway Standards are used for this purpose. These include (1) HL-93 Truck, (2) Lane and (3) Tandem Loadings in addition to (4) Military tank loading, (5) Class-A, (6) Class-B and (7) Class-AA loading, (8) NLC (National Logistic Cell) and (9) Volvo truck loadings. Bridge superstructure including transom beam is analyzed Using ASD and LRFD (Load and Resistance Factor Design) provisions of AASHTO specifications. For the analysis, two longer and shorter spans are selected. This includes the analysis of bridge deck; interior and exterior girder; a typical transom beam and a pier. Dead and live loading determination is carried out using both computer aided and manual calculations. Evaluation of traffic loadings is done for all the bridge components to find out the critical loading. HL-93 loading comes out to be the most critical loading and where this loading is not critical in case of bridge decks; a factor of 1.15 is introduced to make it equivalent with HL-93 -Ioading. SAP-2000 (Structural Engineering Services of Pakistan) and MS-Excel is employed for analysis of bridge superstructure subjected to this loading. Internal forces are obtained for the structural elements of the bridge for all traffic loadings mentioned. It is concluded that HL-93 loading can be used for the design of prestressed concrete girder bridge. Bridge design authorities like NHA (National Highway Authority) and different cities development authorities are using different standard traffic loadings. A number of suggestions are made from the results of the research work related to traffic loadings and method of design. These recommendations may be

  19. Range Scheduling Aid (RSA)

    Science.gov (United States)

    Logan, J. R.; Pulvermacher, M. K.

    1991-01-01

    Range Scheduling Aid (RSA) is presented in the form of the viewgraphs. The following subject areas are covered: satellite control network; current and new approaches to range scheduling; MITRE tasking; RSA features; RSA display; constraint based analytic capability; RSA architecture; and RSA benefits.

  20. On Range of Skill

    DEFF Research Database (Denmark)

    Hansen, Thomas Dueholm; Miltersen, Peter Bro; Sørensen, Troels Bjerre

    2008-01-01

    size (and doubly exponential in its depth). We also provide techniques that yield concrete bounds for unbalanced game trees and apply these to estimate the Range of Skill of Tic-Tac-Toe and Heads-Up Limit Texas Hold'em Poker. In particular, we show that the Range of Skill of Tic-Tac-Toe is more than...

  1. Autonomous Target Ranging Techniques

    DEFF Research Database (Denmark)

    Jørgensen, Peter Siegbjørn; Jørgensen, John Leif; Denver, Troelz

    2003-01-01

    of this telescope, a fast determination of the range to and the motion of the detected targets are important. This is needed in order to prepare the future observation strategy for each target, i.e. when is the closest approach where imaging will be optimal. In order to quickly obtain such a determination two...... ranging strategies are presented. One is an improved laser ranger with an effective range with non-cooperative targets of at least 10,000 km, demonstrated in ground tests. The accuracy of the laser ranging will be approximately 1 m. The laser ranger may furthermore be used for trajectory determination...... of nano-gravity probes, which will perform direct mass measurements of selected targets. The other is triangulation from two spacecraft. For this method it is important to distinguish between detection and tracking range, which will be different for Bering since different instruments are used...

  2. Soliton microcomb range measurement

    Science.gov (United States)

    Suh, Myoung-Gyun; Vahala, Kerry J.

    2018-02-01

    Laser-based range measurement systems are important in many application areas, including autonomous vehicles, robotics, manufacturing, formation flying of satellites, and basic science. Coherent laser ranging systems using dual-frequency combs provide an unprecedented combination of long range, high precision, and fast update rate. We report dual-comb distance measurement using chip-based soliton microcombs. A single pump laser was used to generate dual-frequency combs within a single microresonator as counterpropagating solitons. We demonstrated time-of-flight measurement with 200-nanometer precision at an averaging time of 500 milliseconds within a range ambiguity of 16 millimeters. Measurements at distances up to 25 meters with much lower precision were also performed. Our chip-based source is an important step toward miniature dual-comb laser ranging systems that are suitable for photonic integration.

  3. Phosphorous loads evaluation from soil

    International Nuclear Information System (INIS)

    Mezzanotte, V.

    1996-01-01

    With reference to the well known difficulty of quantifying non point phosphorous loads, as well as to their growing relative importance where point source leads decrease, a literature review has been carried out concerning soil export coefficients. On such basis, the values which seem to be the most appropriate for Italy have been estimated for different land use categories. The main mechanisms determining non point phosphorous load generation and the factors affecting their importance are also described. In the end, criteria for estimating the importance of non point sources in a basin are suggested to be used for deciding whether a traditional, parametric assessment (inevitably involving a certain error) can be acceptable or experimental measures are needed

  4. The analysis of loading losses from tank trucks

    Directory of Open Access Journals (Sweden)

    Jovanović Ana P.

    2006-01-01

    Full Text Available The quantity of loading losses, which are the primary source of evaporative emissions from tank cars and trucks was analyzed in this paper. Loading losses occur as organic vapors in "empty" cargo tanks are displaced to the atmosphere by the liquid being loaded into the tanks. Emissions from loading petroleum liquid were estimated using three methods: the API (American Petroleum Institute method, the VDI (Verein Deutscher Ingenieure -Association of German Engineers method and the Yugoslav Standard JUS B.HO.531 method. The mass of evaporative losses from loading operations is a function of the following parameters: the method of loading the cargo, the physical and chemical characteristics of the cargo and the ambient temperature during loading. Evaporation losses from the loading of motor gasoline (MB-95, BMB-95, MB-98 and MB-86 and diesel fuels (D-2, Euro D-2 were calculated. Losses on a monthly and annual basis were presented for an assumed amount of loaded cargo. It was estimated that the highest loading losses occur in the summer period because of high ambient daily temperatures and in the period of higher transporting levels. It should be pointed out that the loading losses of diesel fuel calculated using an empirical coefficient according to JUS B.HO.531 are significantly higher in comparison with the loading losses calculated using emission factors from the EPA and the VDI method. The gasoline loading losses calculated using emission factors derived from the three methods are similar.

  5. Attentional capture under high perceptual load.

    Science.gov (United States)

    Cosman, Joshua D; Vecera, Shaun P

    2010-12-01

    Attentional capture by abrupt onsets can be modulated by several factors, including the complexity, or perceptual load, of a scene. We have recently demonstrated that observers are less likely to be captured by abruptly appearing, task-irrelevant stimuli when they perform a search that is high, as opposed to low, in perceptual load (Cosman & Vecera, 2009), consistent with perceptual load theory. However, recent results indicate that onset frequency can influence stimulus-driven capture, with infrequent onsets capturing attention more often than did frequent onsets. Importantly, in our previous task, an abrupt onset was present on every trial, and consequently, attentional capture might have been affected by both onset frequency and perceptual load. In the present experiment, we examined whether onset frequency influences attentional capture under conditions of high perceptual load. When onsets were presented frequently, we replicated our earlier results; attentional capture by onsets was modulated under conditions of high perceptual load. Importantly, however, when onsets were presented infrequently, we observed robust capture effects. These results conflict with a strong form of load theory and, instead, suggest that exposure to the elements of a task (e.g., abrupt onsets) combines with high perceptual load to modulate attentional capture by task-irrelevant information.

  6. Macrophyte Community Response to Nitrogen Loading and ...

    Science.gov (United States)

    Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of NO3 loading (0, 1.5, 3 and 6x ambient) and temperature (10 and 20 °C). Macroalgal growth, biomass, and C:N responded positively to increased NO3 load and floating algal mats developed at 20 ºC. Zostera japonica metrics, including C:N, responded more to temperature than to NO3 loading. Z. marina biomass exhibited a negative temperature effect and in some cases a negative NO3 effect, while growth rate increased with temperature. Shoot survival decreased at 20 ºC but was not influenced by NO3 loading. Wasting disease index exhibited a significant temperature by NO3 interaction consistent with increased disease susceptibility. Community shifts observed were consistent with the nutrient loading hypothesis at 20 ºC, but there was no evidence of other eutrophication symptoms due to the short residence time. The Nutrient Pollution Index tracked the NO3 gradient at 10 ºC but exhibited no response at 20 ºC. We suggest that systems characterized by cool temperatures, high NO3 loads, and short residence time may be resilient to many symptoms of eutrophication. Estuarine systems characterized by cool temperatures, high nutrient loads and rapid flushing may be resilient to some symptoms

  7. Prediction ranges. Annual review

    Energy Technology Data Exchange (ETDEWEB)

    Parker, J.C.; Tharp, W.H.; Spiro, P.S.; Keng, K.; Angastiniotis, M.; Hachey, L.T.

    1988-01-01

    Prediction ranges equip the planner with one more tool for improved assessment of the outcome of a course of action. One of their major uses is in financial evaluations, where corporate policy requires the performance of uncertainty analysis for large projects. This report gives an overview of the uses of prediction ranges, with examples; and risks and uncertainties in growth, inflation, and interest and exchange rates. Prediction ranges and standard deviations of 80% and 50% probability are given for various economic indicators in Ontario, Canada, and the USA, as well as for foreign exchange rates and Ontario Hydro interest rates. An explanatory note on probability is also included. 23 tabs.

  8. Assessment physical load of dockers in a worker cooperative

    Directory of Open Access Journals (Sweden)

    Hernán D. Zapata

    2011-05-01

    Full Text Available Manual labourers are workers whose job consists of humping goods. Task commonly related to a varied level of mechanical stress due both to its mechanical stress demand and the workplace risk factors. Objectives: to determine the level of exposure to physical workload amongst a sample of manual labourers who work at the factory of food concentrate for animal. To propose general administrative control and working atmosphere measures. Methodology: a study of descriptive observational type by convenience was carried out. The sample consisted of 41 manual labourers who were administered a socio-demographic survey in order to know the population characteristics. To those fulfilling the inclusion criteria, a heart rate monitoring was used. Afterwards, the Frimat method was administered to determine the levels of exposure to physical work load according to workload rates. Statistical analysis favoured was descriptive and non-parametric (Chisquare χ Results: two out of the four work sites under study constitute the most representative workload to personnel. While the study, the three labourers (100% shoving and 14 (63.6% out of the 22 labourers loading goods up and down ranged from hard to extremely tough levels of workload. Conversely, 11(91.7% labourers carrying raw material and 4 (100% sewing sacks were placed under a low level ranging between a minimal and bearable workload. Discussion: the kinds of job as well as the activities related to it affect the level of physical workload. Personal factors can have an influence upon physical workload.

  9. Load Balancing Scientific Applications

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Olga Tkachyshyn [Texas A & M Univ., College Station, TX (United States)

    2014-12-01

    The largest supercomputers have millions of independent processors, and concurrency levels are rapidly increasing. For ideal efficiency, developers of the simulations that run on these machines must ensure that computational work is evenly balanced among processors. Assigning work evenly is challenging because many large modern parallel codes simulate behavior of physical systems that evolve over time, and their workloads change over time. Furthermore, the cost of imbalanced load increases with scale because most large-scale scientific simulations today use a Single Program Multiple Data (SPMD) parallel programming model, and an increasing number of processors will wait for the slowest one at the synchronization points. To address load imbalance, many large-scale parallel applications use dynamic load balance algorithms to redistribute work evenly. The research objective of this dissertation is to develop methods to decide when and how to load balance the application, and to balance it effectively and affordably. We measure and evaluate the computational load of the application, and develop strategies to decide when and how to correct the imbalance. Depending on the simulation, a fast, local load balance algorithm may be suitable, or a more sophisticated and expensive algorithm may be required. We developed a model for comparison of load balance algorithms for a specific state of the simulation that enables the selection of a balancing algorithm that will minimize overall runtime.

  10. Status of load management

    Energy Technology Data Exchange (ETDEWEB)

    Juchymenko, A

    1983-08-01

    A summary is presented of the status of load management, defined as any activity by an electric utility to affect the size and characteristics of its load. Load management is currently viewed by electric utilities as an important tool for marketing electricity in a competitive fuel situation. A major aim of the National Energy Program is to reduce Canada's dependence on oil by 1990 to 10% of the energy used by all markets. As a result, electricity may play a greater role in the supply of primary energy. Research in load management has been directed mostly towards the residential market, especially direct control of domestic hot water heaters and air conditioners. Studies conducted in Canada and the U.S. to determine user's receptiveness to direct control of loads and thermal energy storage systems indicate that these load management techniques are in most cases not acceptable to customers, who prefer voluntary reduction in demand. The potential exists in the industrial market to use load management to assist in electrifying many of the fossil fuel-fired processes at competitive energy prices. Some of the more important applications include an industrial heat pump to heat liquids to 120{degree}C, induction heating for melting and heat treating of metals, and mechanical vapor recompression equipment to produce proces steam. 21 refs., 2 figs., 2 tabs.

  11. Performance of a cognitive load inventory during simulated handoffs: Evidence for validity.

    Science.gov (United States)

    Young, John Q; Boscardin, Christy K; van Dijk, Savannah M; Abdullah, Ruqayyah; Irby, David M; Sewell, Justin L; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-01-01

    Advancing patient safety during handoffs remains a public health priority. The application of cognitive load theory offers promise, but is currently limited by the inability to measure cognitive load types. To develop and collect validity evidence for a revised self-report inventory that measures cognitive load types during a handoff. Based on prior published work, input from experts in cognitive load theory and handoffs, and a think-aloud exercise with residents, a revised Cognitive Load Inventory for Handoffs was developed. The Cognitive Load Inventory for Handoffs has items for intrinsic, extraneous, and germane load. Students who were second- and sixth-year students recruited from a Dutch medical school participated in four simulated handoffs (two simple and two complex cases). At the end of each handoff, study participants completed the Cognitive Load Inventory for Handoffs, Paas' Cognitive Load Scale, and one global rating item for intrinsic load, extraneous load, and germane load, respectively. Factor and correlational analyses were performed to collect evidence for validity. Confirmatory factor analysis yielded a single factor that combined intrinsic and germane loads. The extraneous load items performed poorly and were removed from the model. The score from the combined intrinsic and germane load items associated, as predicted by cognitive load theory, with a commonly used measure of overall cognitive load (Pearson's r = 0.83, p load during handoffs may be measured via a self-report measure. Additional work is required to develop an adequate measure of extraneous load.

  12. Greywater pollution variability and loadings

    DEFF Research Database (Denmark)

    Eriksson, Eva; Andersen, Henrik Rasmus; Madsen, Toke S.

    2009-01-01

    Small on-site greywater treatment and reuse plants are susceptible to high short-term variation in flow and pollutant concentrations. As demonstrated in this study of a bathroom greywater plant in Copenhagen, Denmark, the flow ranges from no-flow periods to high-flow periods reaching 34 l min−1...... per day, whereas the paraben loadings were below 1 mg per person per day. These data are highly relevant for comparing decentralised treatment options with existing end-of-pipe treatments, for feeding into risk assessments and for design purposes....

  13. Antenna Pattern Range (APR)

    Data.gov (United States)

    Federal Laboratory Consortium — TheAntenna Pattern Range (APR)features a non-metallic arch with a trolley to move the transmit antenna from the horizon to zenith. At the center of the ground plane,...

  14. Atlantic Test Range (ATR)

    Data.gov (United States)

    Federal Laboratory Consortium — ATR controls fully-instrumented and integrated test ranges that provide full-service support for cradle-to-grave testing. Airspace and surface target areas are used...

  15. EV range sensitivity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ostafew, C. [Azure Dynamics Corp., Toronto, ON (Canada)

    2010-07-01

    This presentation included a sensitivity analysis of electric vehicle components on overall efficiency. The presentation provided an overview of drive cycles and discussed the major contributors to range in terms of rolling resistance; aerodynamic drag; motor efficiency; and vehicle mass. Drive cycles that were presented included: New York City Cycle (NYCC); urban dynamometer drive cycle; and US06. A summary of the findings were presented for each of the major contributors. Rolling resistance was found to have a balanced effect on each drive cycle and proportional to range. In terms of aerodynamic drive, there was a large effect on US06 range. A large effect was also found on NYCC range in terms of motor efficiency and vehicle mass. figs.

  16. Diffusion Indexes With Sparse Loadings

    DEFF Research Database (Denmark)

    Kristensen, Johannes Tang

    2017-01-01

    The use of large-dimensional factor models in forecasting has received much attention in the literature with the consensus being that improvements on forecasts can be achieved when comparing with standard models. However, recent contributions in the literature have demonstrated that care needs...... to the problem by using the least absolute shrinkage and selection operator (LASSO) as a variable selection method to choose between the possible variables and thus obtain sparse loadings from which factors or diffusion indexes can be formed. This allows us to build a more parsimonious factor model...... in forecasting accuracy and thus find it to be an important alternative to PC. Supplementary materials for this article are available online....

  17. Least square regression based integrated multi-parameteric demand modeling for short term load forecasting

    International Nuclear Information System (INIS)

    Halepoto, I.A.; Uqaili, M.A.

    2014-01-01

    Nowadays, due to power crisis, electricity demand forecasting is deemed an important area for socioeconomic development and proper anticipation of the load forecasting is considered essential step towards efficient power system operation, scheduling and planning. In this paper, we present STLF (Short Term Load Forecasting) using multiple regression techniques (i.e. linear, multiple linear, quadratic and exponential) by considering hour by hour load model based on specific targeted day approach with temperature variant parameter. The proposed work forecasts the future load demand correlation with linear and non-linear parameters (i.e. considering temperature in our case) through different regression approaches. The overall load forecasting error is 2.98% which is very much acceptable. From proposed regression techniques, Quadratic Regression technique performs better compared to than other techniques because it can optimally fit broad range of functions and data sets. The work proposed in this paper, will pave a path to effectively forecast the specific day load with multiple variance factors in a way that optimal accuracy can be maintained. (author)

  18. Passive detection of vehicle loading

    Science.gov (United States)

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.; Salvaggio, Philip S.; McKeown, Donald M.; Garrett, Alfred J.; Coleman, David H.; Koffman, Larry D.

    2012-01-01

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  19. PASSIVE DETECTION OF VEHICLE LOADING

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, A.

    2012-01-03

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  20. Inducer Hydrodynamic Load Measurement Devices

    Science.gov (United States)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  1. Design loads, loading combinations and structural acceptance criteria for BWR containments in the United States

    International Nuclear Information System (INIS)

    Edwards, N.W.

    1979-01-01

    The definition of loads, loading combinations, and structural acceptance criteria used for the design and evaluation of BWR containments in the Unites States has become much more comprehensive over the past decade. The Mark I pressure suppression containment vessels were designed for a static design pressure, a design temperature, dead load and static equivalent earthquake. The current Mark III containments are being designed to accommodate many more loads such as safety relief valve discharge loads, and suppression pool hydrodynamic loadings associated with the steam condensation phenomena as well as pressure and temperature transients for a range of pipe break sizes. Consistent with the more comprehensive definition of loads and loading combinations, the ASME Code presently establishes structural acceptance criteria with different margins of safety by the definition of Service Level Assignments A, B, C and D. Acting in a responsible manner, United States utilities are currently evaluating and modifying existing containment vessels to account for the more detailed load definition and structural acceptance criteria. (orig.)

  2. Lumbriculus variegatus loading study

    Data.gov (United States)

    U.S. Environmental Protection Agency — Results from sediment bioaccumulation tests with Lumbriculus variegatus with evaluating the effects of organism loading density. This dataset is associated with the...

  3. LOADING SIMULATION PROGRAM C

    Science.gov (United States)

    LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for simulating hydrology, sediment, and general water quality

  4. LOADING SIMULATION PROGRAM C

    Data.gov (United States)

    U.S. Environmental Protection Agency — LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for...

  5. Cognitive load theory

    NARCIS (Netherlands)

    Kirschner, Paul A.; Kirschner, Femke; Paas, Fred

    2010-01-01

    Kirschner, P. A., Kirschner, F. C., & Paas, F. (2009). Cognitive load theory. In E. M. Anderman & L. H. Anderman (Eds.). Psychology of classroom learning: An encyclopedia, Volume 1, a-j (pp. 205-209). Detroit, MI: Macmillan Reference.

  6. Static Loads Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides the capability to perform large-scale structural loads testing on spacecraft and other structures. Results from these tests can be used to verify...

  7. Load proportional safety brake

    Science.gov (United States)

    Cacciola, M. J.

    1979-01-01

    This brake is a self-energizing mechanical friction brake and is intended for use in a rotary drive system. It incorporates a torque sensor which cuts power to the power unit on any overload condition. The brake is capable of driving against an opposing load or driving, paying-out, an aiding load in either direction of rotation. The brake also acts as a no-back device when torque is applied to the output shaft. The advantages of using this type of device are: (1) low frictional drag when driving; (2) smooth paying-out of an aiding load with no runaway danger; (3) energy absorption proportional to load; (4) no-back activates within a few degrees of output shaft rotation and resets automatically; and (5) built-in overload protection.

  8. Plug Load Data

    Data.gov (United States)

    National Aeronautics and Space Administration — We provide MATLAB binary files (.mat) and comma separated values files of data collected from a pilot study of a plug load management system that allows for the...

  9. Probabilistic representation of duration of load effects in timber structures

    DEFF Research Database (Denmark)

    Svensson, Staffan

    2011-01-01

    Reliability analysis of structures for the purpose of code calibration or reliability verification of specific structures requires that the relevant failure modes are represented and analyzed. For structural timber, sustaining a life load, two failure cases for each failure mode have......-based design of timber structures in terms of a modification factor View the MathML source which is multiplied on the short-term resistance of the timber material. The scenario of a beam subject to office space life loads is analyzed and the modification factor View the MathML source is calibrated by using...... to be considered. These two cases are maximum load level exceeding load-carrying capacity and damage accumulation (caused by the load and its duration) leading to failure. The effect of both load intensity and load duration on the capacity of timber has been an area of large interest over the last decades...

  10. Range Selection and Median

    DEFF Research Database (Denmark)

    Jørgensen, Allan Grønlund; Larsen, Kasper Green

    2011-01-01

    and several natural special cases thereof. The rst special case is known as range median, which arises when k is xed to b(j 􀀀 i + 1)=2c. The second case, denoted prex selection, arises when i is xed to 0. Finally, we also consider the bounded rank prex selection problem and the xed rank range......Range selection is the problem of preprocessing an input array A of n unique integers, such that given a query (i; j; k), one can report the k'th smallest integer in the subarray A[i];A[i+1]; : : : ;A[j]. In this paper we consider static data structures in the word-RAM for range selection...... selection problem. In the former, data structures must support prex selection queries under the assumption that k for some value n given at construction time, while in the latter, data structures must support range selection queries where k is xed beforehand for all queries. We prove cell probe lower bounds...

  11. Enhanced sensitivity fibre Bragg grating (FBG) load sensor

    International Nuclear Information System (INIS)

    Correia, Ricardo; Chehura, Edmon; Li, Jin; James, Stephen W; Tatam, Ralph P

    2010-01-01

    The characterization of a load sensor based on the transverse loading of a subsection of a fibre Bragg grating (FBG) embedded within a cube of epoxy resin is presented. When the epoxy resin cube is loaded transverse to the axis of the fibre, its deformation transduces the load to a strain along the axis of the optical fibre, which changes the period of the embedded section of the FBG. This creates a spectral dropout within the bandwidth of the FBG, with an absolute wavelength that is linearly dependent on the applied load. This technique enhances the sensitivity of the FBG to transverse loading by a factor of 15, to 2.9 × 10 −2 ± 0.01 nm N −1 , when compared to the direct transverse loading of a bare fibre, and also protects the fibre from mechanical damage at the loading point

  12. Handball load and shoulder injury rate

    DEFF Research Database (Denmark)

    Møller, M.; Nielsen, R.O.; Attermann, J.

    2017-01-01

    Background Knowledge of injury patterns, an essential step towards injury prevention, is lacking in youth handball. Aim To investigate if an increase in handball load is associated with increased shoulder injury rates compared with a minor increase or decrease, and if an association is influenced...... by scapular control, isometric shoulder strength or glenohumeral range of motion (ROM). Methods 679 players (14-18 years) provided weekly reports on shoulder injury and handball load (training and competition hours) over 31 weeks using the SMS, phone and medical examination system. Handball load in a given...... week was categorised into (1) 60% relative to the weekly average amount of handball load the preceding 4 weeks. Assessment of shoulder isometric rotational and abduction strength, ROM and scapular control...

  13. Load power device, system and method of load control and management employing load identification

    Science.gov (United States)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  14. Perceptual load in different regions of the visual scene and its relevance for driving.

    Science.gov (United States)

    Marciano, Hadas; Yeshurun, Yaffa

    2015-06-01

    The aim of this study was to better understand the role played by perceptual load, at both central and peripheral regions of the visual scene, in driving safety. Attention is a crucial factor in driving safety, and previous laboratory studies suggest that perceptual load is an important factor determining the efficiency of attentional selectivity. Yet, the effects of perceptual load on driving were never studied systematically. Using a driving simulator, we orthogonally manipulated the load levels at the road (central load) and its sides (peripheral load), while occasionally introducing critical events at one of these regions. Perceptual load affected driving performance at both regions of the visual scene. Critically, the effect was different for central versus peripheral load: Whereas load levels on the road mainly affected driving speed, load levels on its sides mainly affected the ability to detect critical events initiating from the roadsides. Moreover, higher levels of peripheral load impaired performance but mainly with low levels of central load, replicating findings with simple letter stimuli. Perceptual load has a considerable effect on driving, but the nature of this effect depends on the region of the visual scene at which the load is introduced. Given the observed importance of perceptual load, authors of future studies of driving safety should take it into account. Specifically, these findings suggest that our understanding of factors that may be relevant for driving safety would benefit from studying these factors under different levels of load at different regions of the visual scene. © 2014, Human Factors and Ergonomics Society.

  15. Hood River Conservation Project load analysis

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.

    1987-11-01

    As a part of the Hood River Conservation Project (HRCP), 314 homes were monitored to measure electrical energy use. The total electrical load, space heating load, water heating load (in about 200 homes), wood-stove heat output (in about 100 homes), and indoor temperature were monitored. Data were collected for one full year before and one full year after these homes were retrofit with conservation measures. Local weather information was also collected on a 15-min basis. This data base was used to evaluate the load savings attributable to HRCP. Two methods of weather normalization were used and showed close agreement. The weather-normalized diversified residential load savings on the Pacific Power and Light system and Hood River area peak days were >0.5 kW/household. The average spring, summer, and fall savings were much smaller, <0.1 kW/household. The load factor for the diversified residential load decreased following the conservation retrofit actions. 11 refs., 40 figs., 13 tabs.

  16. Online Sorted Range Reporting

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Fagerberg, Rolf; Greve, Mark

    2009-01-01

    is motivated by (and is a generalization of) a problem with applications in search engines: On a tree where leaves have associated rank values, report the highest ranked leaves in a given subtree. Finally, the problem studied generalizes the classic range minimum query (RMQ) problem on arrays....

  17. Substring Range Reporting

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li

    2014-01-01

    We revisit various string indexing problems with range reporting features, namely, position-restricted substring searching, indexing substrings with gaps, and indexing substrings with intervals. We obtain the following main results. We give efficient reductions for each of the above problems...

  18. Substring Range Reporting

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li

    2011-01-01

    We revisit various string indexing problems with range reporting features, namely, position-restricted substring searching, indexing substrings with gaps, and indexing substrings with intervals. We obtain the following main results. – We give efficient reductions for each of the above problems...

  19. Range-clustering queries

    NARCIS (Netherlands)

    Abrahamsen, M.; de Berg, M.T.; Buchin, K.A.; Mehr, M.; Mehrabi, A.D.

    2017-01-01

    In a geometric k -clustering problem the goal is to partition a set of points in R d into k subsets such that a certain cost function of the clustering is minimized. We present data structures for orthogonal range-clustering queries on a point set S : given a query box Q and an integer k>2 , compute

  20. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions.

    Science.gov (United States)

    Kovochich, Michael; Fung, Ernest S; Donovan, Ellen; Unice, Kenneth M; Paustenbach, Dennis J; Finley, Brent L

    2018-04-01

    Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (edge-loading conditions generated particles that ranged from Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018. © 2017 Wiley Periodicals, Inc.

  1. Study on Mechanical Properties of Barite Concrete under Impact Load

    Science.gov (United States)

    Chen, Z. F.; Cheng, K.; Wu, D.; Gan, Y. C.; Tao, Q. W.

    2018-03-01

    In order to research the mechanical properties of Barite concrete under impact load, a group of concrete compression tests was carried out under the impact load by using the drop test machine. A high-speed camera was used to record the failure process of the specimen during the impact process. The test results show that:with the increase of drop height, the loading rate, the peak load, the strain under peak load, the strain rate and the dynamic increase factor (DIF) all increase gradually. The ultimate tensile strain is close to each other, and the time of impact force decreases significantly, showing significant strain rate effect.

  2. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    Science.gov (United States)

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2018-04-01

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. Wrist loading patterns during pommel horse exercises.

    Science.gov (United States)

    Markolf, K L; Shapiro, M S; Mandelbaum, B R; Teurlings, L

    1990-01-01

    Gymnastics is a sport which involves substantial periods of upper extremity support as well as frequent impacts to the wrist. Not surprisingly, wrist pain is a common finding in gymnasts. Of all events, the pommel horse is the most painful. In order to study the forces of wrist impact, a standard pommel horse was instrumented with a specially designed load cell to record the resultant force of the hand on the pommel during a series of basic skills performed by a group of seventeen elite male gymnasts. The highest mean peak forces were recorded during the front scissors and flair exercises (1.5 BW) with peaks of up to 2.0 BW for some gymnasts. The mean peak force for hip circles at the center or end of the horse was 1.1 BW. The mean overall loading rate (initial contact to first loading peak) ranged from 5.2 BWs-1 (hip circles) to 10.6 BW s-1 (flairs). However, many recordings displayed localized initial loading spikes which occurred during 'hard' landings on the pommel. When front scissors were performed in an aggressive manner, the initial loading spikes averaged 1.0 BW in magnitude (maximum 1.8 BW) with an average rise time of 8.2 ms; calculated localized loading rates averaged 129 BW s-1 (maximum 219 BW s-1). These loading parameters are comparable to those encountered at heel strike during running. These impact forces and loading rates are remarkably high for an upper extremity joint not normally exposed to weight-bearing loads, and may contribute to the pathogenesis of wrist injuries in gymnastics.

  4. Implications of stress range for inelastic analysis

    International Nuclear Information System (INIS)

    Karabin, M.E.; Dhalla, A.K.

    1981-01-01

    The elastic stress range over a complete load cycle is routinely used to formulate simplified rules regarding the inelastic behavior of structures operating at elevated temperature. For example, a 300 series stainless steel structure operating at elevated temperature, in all probability, would satisfy the ASME Boiler and Pressure Vessel Code criteria if the linearized elastic stress range is less than three times the material yield strength. However, at higher elastic stress ranges it is difficult to judge, a priori, that a structural component would comply with inelastic Code criteria after a detailed inelastic analysis. The purpose of this paper is to illustrate that it is not the elastic stress range but the stress intensities at specific times during a thermal transient which provide a better insight into the inelastic response of the structure. The specific example of the CRBRP flued head design demonstrates that the temperature differential between various parts of the structure can be changed by modifying the insulation pattern and heat flow path in the structure, without significantly altering the elastic stress range over a complete load cycle. However, the modified design did reduce the stress intensity during steady state elevated temperature operation. This modified design satisfied the inelastic Code criteria whereas the initial design failed to comply with the strain accumulation criterion

  5. Preliminary assessment of the effects of biaxial loading on reactor pressure vessel structural-integrity-assessment technology

    International Nuclear Information System (INIS)

    Pennell, W.E.; Bass, B.R.; Bryson, J.W.; Dickson, T.L.; McAfee, W.J.; Merkle, J.G.

    1996-01-01

    Effects of biaxial loading on shallow-flaw fracture toughness were studied to determine potential impact on structural integrity assessment of a reactor pressure vessel (RPV) under pressurized thermal shock (PTS) transient loading and pressure-temperature (PT) loading produced by reactor heatup and cooldown transients. Biaxial shallow-flaw fracture-toughness tests results were also used to determine the parameter controlling fracture in the transition temperature range, and to develop a related dual-parameter fracture-toughness correlation. Shallow-flaw and biaxial loading effects were found to reduce the conditional probability of crack initiation by a factor of nine when the shallow-flaw fracture-toughness K Jc data set, with biaxial-loading effects adjustments, was substituted in place of ASME Code K Ic data set in PTS analyses. Biaxial loading was found to reduce the shallow-flaw fracture toughness of RPV steel such that the lower-bound curve was located between ASME K Ic and K IR curves. This is relevant to future development of P-T curve analysis procedures. Fracture in shallow-flaw biaxial samples tested in the lower transition temperature range was shown to be strain controlled. A strain-based dual-parameter fracture-toughness correlation was developed and shown to be capable of predicting the effect of crack-tip constraint on fracture toughness for strain-controlled fracture

  6. Extended Range Intercept Technology

    Science.gov (United States)

    1991-09-01

    1988). Desert bighorn ewes with lambs show a stronger response than do groups of only rams, only ewes, or mixed groups of adults (Miller and Smith...1985). While all startle events may affect desert bighorns, those occurring during the lambing period (February-April) would represent the highest...35807 U.S. Army Pueblo Depot Activity SDSTE-PU-EE Pueblo, CO 81001-5000 U.S. Army White Sands Missile Range STEWS -EL-N White Sands, NM 88002-5076

  7. ORANGE: RANGE OF BENEFITS

    OpenAIRE

    Parle Milind; Chaturvedi Dev

    2012-01-01

    No wonder that oranges are one of the most popular fruits in the world. Orange (citrus sinensis) is well known for its nutritional and medicinal properties throughout the world. From times immemorial, whole Orange plant including ripe and unripe fruits, juice, orange peels, leaves and flowers are used as a traditional medicine. Citrus sinensis belongs to the family Rutaceae. The fruit is a fleshy, indehiscent, berry that ranges widely in size from 4 cm to 12 cm. The major medicinal proper...

  8. Emission factors and chemical characterisation of fine particulate emissions from modern and old residential biomass heating systems determined for typical load cycles; Emissionsfaktoren und chemische Charakterisierung von Feinstaubemissionen moderner und alter Biomasse-Kleinfeuerungen ueber typische Tageslastverlaeufe

    Energy Technology Data Exchange (ETDEWEB)

    Kelz, Joachim [BIOENERGY 2020+ GmbH, Graz (Austria); Brunner, Thomas; Obernberger, Ingwald [BIOENERGY 2020+ GmbH, Graz (Austria); Technische Universitaet Graz, Institut fuer Prozess- und Partikeltechnik, Graz (Austria); BIOS BIOENERGIESYSTEME GmbH, Graz (Austria)

    2012-12-15

    It is already well known that there are significant differences regarding the emissions, especially particulate matter (PM) emissions, of old and modern as well as automatically and not automatically controlled biomass based residential heating systems. This concerns their magnitude as well as their chemical composition. In order to investigate emission factors for particulate emissions and the chemical compositions of the PM emissions over typical whole day operation cycles, a project on the determination and characterisation of PM emissions from the most relevant small-scale biomass combustion systems was performed at the BIOENERGY 2020+ GmbH, Graz, Austria, in cooperation with the Institute for Process and Particle Engineering, Graz University of Technology. The project was based on test stand measurements, during which relevant operation parameters (gaseous emissions, boiler load, flue gas temperature, combustion chamber temperature etc.) as well as PM emissions have been measured and PM samples have been taken and forwarded to chemical analyses. Firstly, typical whole day operation cycles for residential biomass combustion systems were specified for the test runs. Thereby automatically fed and automatically controlled boilers, manually fed and automatically controlled boilers as well as manually fed stoves were distinguished. The results show a clear correlation between the gaseous emissions (CO and OGC) and the PM{sub 1} emissions. It is indicated that modern biomass combustion systems emit significantly less gaseous and PM emissions than older technologies (up to a factor of 100). Moreover, automatically fed systems emit much less gaseous and PM emissions than manually fed batch-combustion systems. PM emissions from modern and automatically controlled systems mainly consist of alkaline metal salts, while organic aerosols and soot dominate the composition of aerosols from old and not automatically controlled systems. As an important result comprehensive data

  9. Comparison of Water-Load Distributions Obtained during Seaplane Landings with Bureau of Aeronautics Specifications. TED No. NACA 2413

    Science.gov (United States)

    Smiley, Robert F.; Haines, Gilbert A.

    1949-01-01

    Bureau of Aeronautics Design Specifications SS-IC-2 for water loads in sheltered water are compared with experimental water loads obtained during a full--scale landing investigation. This investigation was conducted with a JRS-1 flying boat which has a 20 degrees dead-rise V-bottom with a partial chine flare. The range of landing conditions included airspeeds between 88 and 126 feet per second, sinking speeds between 1.6 and 9.1 feet per second, flight angles less than 6 degrees, and trims between 2 degrees and 12 degrees. Landings were moderate and were made in calm water. Measurements were obtained of maximum over-all loads, maximum pitching moments, and pressure distributions. Maximum experimental loads include over-all load factors of 2g, moments of 128,000 pound-feet, and maximum local pressures greater than 40 pounds per square inch. Experimental over-all loads are approximately one-half the design values, while local pressures are of the same order as or larger than pressures calculated from specifications for plating, stringer, floor, and frame design. The value of this comparison is limited, to some extent, by the moderate conditions of the test and by the necessary simplifying assumptions used in comparing the specifications with the experimental loads.

  10. Range Flight Safety Requirements

    Science.gov (United States)

    Loftin, Charles E.; Hudson, Sandra M.

    2018-01-01

    The purpose of this NASA Technical Standard is to provide the technical requirements for the NPR 8715.5, Range Flight Safety Program, in regards to protection of the public, the NASA workforce, and property as it pertains to risk analysis, Flight Safety Systems (FSS), and range flight operations. This standard is approved for use by NASA Headquarters and NASA Centers, including Component Facilities and Technical and Service Support Centers, and may be cited in contract, program, and other Agency documents as a technical requirement. This standard may also apply to the Jet Propulsion Laboratory or to other contractors, grant recipients, or parties to agreements to the extent specified or referenced in their contracts, grants, or agreements, when these organizations conduct or participate in missions that involve range flight operations as defined by NPR 8715.5.1.2.2 In this standard, all mandatory actions (i.e., requirements) are denoted by statements containing the term “shall.”1.3 TailoringTailoring of this standard for application to a specific program or project shall be formally documented as part of program or project requirements and approved by the responsible Technical Authority in accordance with NPR 8715.3, NASA General Safety Program Requirements.

  11. A comparison of measured wind park load histories with the WISPER and WISPERX load spectra

    Science.gov (United States)

    Kelley, N. D.

    1995-01-01

    The blade-loading histories from two adjacent Micon 65/13 wind turbines are compared with the variable-amplitude test-loading histories known as the WISPER and WISPERX spectra. These standardized loading sequences were developed from blade flapwise load histories taken from nine different horizontal-axis wind turbines operating under a wide range of conditions in Europe. The subject turbines covered a broad spectrum of rotor diameters, materials, and operating environments. The final loading sequences were developed as a joint effort of thirteen different European organizations. The goal was to develop a meaningful loading standard for horizontal-axis wind turbine blades that represents common interaction effects seen in service. In 1990, NREL made extensive load measurements on two adjacent Micon 65/13 wind turbines in simultaneous operation in the very turbulent environment of a large wind park. Further, before and during the collection of the loads data, comprehensive measurements of the statistics of the turbulent environment were obtained at both the turbines under test and at two other locations within the park. The trend to larger but lighter wind turbine structures has made an understanding of the expected lifetime loading history of paramount importance. Experience in the US has shown that the turbulence-induced loads associated with multi-row wind parks in general are much more severe than for turbines operating individually or within widely spaced environments. Multi-row wind parks are much more common in the US than in Europe. In this paper we report on our results in applying the methodology utilized to develop the WISPER and WISPERX standardized loading sequences using the available data from the Micon turbines. While the intended purpose of the WISPER sequences were not to represent a specific operating environment, we believe the exercise is useful, especially when a turbine design is likely to be installed in a multi-row wind park.

  12. Effective dose range for dental cone beam computed tomography scanners

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Beinsberger, Jilke; Collaert, Bruno; Theodorakou, Chrysoula; Rogers, Jessica; Walker, Anne; Cockmartin, Lesley; Bosmans, Hilde; Jacobs, Reinhilde; Bogaerts, Ria; Horner, Keith

    2012-01-01

    Objective: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. Materials and methods: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. Results: Effective dose ranged between 19 and 368 μSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. Conclusions: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.

  13. Ocean Tide Loading Computation

    Science.gov (United States)

    Agnew, Duncan Carr

    2005-01-01

    September 15,2003 through May 15,2005 This grant funds the maintenance, updating, and distribution of programs for computing ocean tide loading, to enable the corrections for such loading to be more widely applied in space- geodetic and gravity measurements. These programs, developed under funding from the CDP and DOSE programs, incorporate the most recent global tidal models developed from Topex/Poscidon data, and also local tide models for regions around North America; the design of the algorithm and software makes it straightforward to combine local and global models.

  14. DYNAMIC LOAD DAMPER MODELING

    Directory of Open Access Journals (Sweden)

    Loktev Aleksey Alekseevich

    2013-01-01

    Full Text Available The authors present their findings associated with their modeling of a dynamic load damper. According to the authors, the damper is to be installed onto a structure or its element that may be exposed to impact, vibration or any other dynamic loading. The damper is composed of paralleled or consecutively connected viscous and elastic elements. The authors study the influence of viscosity and elasticity parameters of the damper produced onto the regular displacement of points of the structure to be protected and onto the regular acceleration transmitted immediately from the damper to the elements positioned below it.

  15. Evaluation of resilient abutment components on measured strain using dynamic loading conditions.

    Science.gov (United States)

    Morton, D; Stanford, C M; Aquilino, S A

    1998-07-01

    Factors that affect transmission of strain from prostheses to bone may affect the long-term success of loaded implants. Current in vitro models are theoretically predictive (finite element modeling) or facsimile (photoelastic) in nature. A more clinically relevant in vitro model for strain evaluation should be investigated. This study attempted: (1) to validate a human cadaver bone model for vitro measurement of cortical bone strain, and (2) to evaluate the effect on cortical strain measurements of a resilient plastic component incorporated within a titanium implant in response to variable dynamic loading. Two IMZ (Interpore International) abutment alternatives were used: the titanium Abutment Complete and the polyoxymethylene Intra-mobile Element. The model system consisted of two implants placed in unfixed human cadaver ulna bone to simulate an implant bound edentulous region. Four biaxial rosette strain gauges simultaneously recorded cortical bone strain immediately mesial and distal to each implant. During experimentation a simulated prosthetic framework supported by either titanium or polyoxymethylene abutments was dynamically loaded 6 min from the terminal abutment along a cantilever extension. Cyclic nominal peak loads were applied with a materials testing machine at 20-N intervals from 20 to 200 N at a crosshead speed of 5 mm/minute. The protocol allowed frequency of load application to vary. A Newtonian linear correlation (r2 > or = 0.98) between load application and strain output was determined for each gauge position except for the terminal gauge located opposite the cantilever. Cortical strains recorded were within reported physiologic ranges involved in bone modeling and remodeling. Further, the polyoxymethylene abutment components did not result in reduction of peak microstrain at any gauge position. The Intra-mobile Element abutments, however, did increase the time required to complete 10 loading cycles when compared with the titanium Abutment

  16. Long-range antigravity

    Energy Technology Data Exchange (ETDEWEB)

    Macrae, K.I.; Riegert, R.J. (Maryland Univ., College Park (USA). Center for Theoretical Physics)

    1984-10-01

    We consider a theory in which fermionic matter interacts via long-range scalar, vector and tensor fields. In order not to be in conflict with experiment, the scalar and vector couplings for a given fermion must be equal, as is natural in a dimensionally reduced model. Assuming that the Sun is not approximately neutral with respect to these new scalar-vector charges, and if the couplings saturate the experimental bounds, then their strength can be comparable to that of gravity. Scalar-vector fields of this strength can compensate for a solar quadrupole moment contribution to Mercury's anomalous perihelion precession.

  17. Long-range antigravity

    International Nuclear Information System (INIS)

    Macrae, K.I.; Riegert, R.J.

    1984-01-01

    We consider a theory in which fermionic matter interacts via long-range scalar, vector and tensor fields. In order not to be in conflict with experiment, the scalar and vector couplings for a given fermion must be equal, as is natural in a dimensionally reduced model. Assuming that the Sun is not approximately neutral with respect to these new scalar-vector charges, and if the couplings saturate the experimental bounds, then their strength can be comparable to that of gravity. Scalar-vector fields of this strength can compensate for a solar quadrupole moment contribution to Mercury's anomalous perihelion precession. (orig.)

  18. Range Process Simulation Tool

    Science.gov (United States)

    Phillips, Dave; Haas, William; Barth, Tim; Benjamin, Perakath; Graul, Michael; Bagatourova, Olga

    2005-01-01

    Range Process Simulation Tool (RPST) is a computer program that assists managers in rapidly predicting and quantitatively assessing the operational effects of proposed technological additions to, and/or upgrades of, complex facilities and engineering systems such as the Eastern Test Range. Originally designed for application to space transportation systems, RPST is also suitable for assessing effects of proposed changes in industrial facilities and large organizations. RPST follows a model-based approach that includes finite-capacity schedule analysis and discrete-event process simulation. A component-based, scalable, open architecture makes RPST easily and rapidly tailorable for diverse applications. Specific RPST functions include: (1) definition of analysis objectives and performance metrics; (2) selection of process templates from a processtemplate library; (3) configuration of process models for detailed simulation and schedule analysis; (4) design of operations- analysis experiments; (5) schedule and simulation-based process analysis; and (6) optimization of performance by use of genetic algorithms and simulated annealing. The main benefits afforded by RPST are provision of information that can be used to reduce costs of operation and maintenance, and the capability for affordable, accurate, and reliable prediction and exploration of the consequences of many alternative proposed decisions.

  19. In vivo facet joint loading of the canine lumbar spine.

    Science.gov (United States)

    Buttermann, G R; Schendel, M J; Kahmann, R D; Lewis, J L; Bradford, D S

    1992-01-01

    This study describes a technique to measure in vivo loads and the resultant load-contact locations in the facet joint of the canine lumbar spine. The technique is a modification of a previously described in vitro method that used calibrated surface strains of the lateral aspect of the right L3 cranial articular process. In the present study, strains were measured during various in vivo static and dynamic activities 3 days after strain gage implantation. The in vivo recording technique and its errors, which depend on the location of the applied facet loads, is described. The results of applying the technique to five dogs gave the following results. Relative resultant contact load locations on the facet tended to be in the central and caudal portion of the facet in extension activities, central and cranial in standing, and cranial and ventral in flexion or right-turning activities. Right-turning contact locations were ventral and cranial to left-turning locations. Resultant load locations at peak loading during walking were in the central region of the facet, whereas resultant load locations at minimum loading during walking were relatively craniad. This resultant load-contact location during a walk gait cycle typically migrated in an arc with a displacement of 4 mm from minimum to maximum loading. Static tests resulted in a range of facet loads of 0 N in flexion and lying to 185 N for two-legged standing erect, and stand resulted in facet loads of 26 +/- 15 N (mean +/- standard deviation [SD]). Dynamic tests resulted in peak facet loads ranging from 55 N while walking erect to 170 N for climbing up stairs. Maximum walk facet loads were 107 +/- 27 N. The technique is applicable to in vivo studies of a canine facet joint osteoarthritis model and may be useful for establishing an understanding of the biomechanics of low-back pain.

  20. Lateral loadings on snubber assemblies

    International Nuclear Information System (INIS)

    Raphael, L.S.

    1981-01-01

    This paper examines the installation of snubber assemblies in power plants with respect to transverse or lateral loads as well as axial loads. Evaluation of the effects of low level, lateral loads was performed by analytical means. At higher loadings, the snubber assembly could no longer be treated as a column; therefore, the effects of lateral loadings was determined by test. The test consisted of applying both lateral and axial loads simultaneously. Results of both the analysis and the test showed that the application of lateral loads had a considerable effect on the snubber assemblies