WorldWideScience

Sample records for facility-level hb measurement

  1. Diagnosis of Compound Heterozygous Hb Tak/β-Thalassemia and HbD-Punjab/β-Thalassemia by HbA2 Levels on Capillary Electrophoresis.

    Science.gov (United States)

    Panyasai, Sitthichai; Sakkhachornphop, Supachai; Pornprasert, Sakorn

    2018-01-01

    A misdiagnosis of β-thalassemia carrier in samples with Hb Tak and HbD-Punjab, the β-variants, can be a cause of inappropriate genetic counseling thus having a new case of β-thalassemia major. A capillary electrophoresis (CE) is very efficient in separating and quantifying HbA 2 . In this study, HbA 2 levels of samples which were doubted for compound heterozygous Hb Tak/β-thalassemia or heterozygous HbD-Punjab/β-thalassemia were measured and compared between CE and high performance liquid chromatography (HPLC). The molecular confirmation for Hb Tak, HbD-Punjab and β-thalassemia codons 17 (A > T), 41/42 (-TCTT), 71/72 (+A) and IVSI-nt1 (G > T) mutations and 3.4 kb deletion were also performed. Based on DNA analysis, 3 cases were diagnosed as compound heterozygous Hb Tak/β-thalassemia and one for HbD-Punjab/β-thalassemia. The elevated HbA 2 levels were found in all 4 samples with rages of 4.6-7.3% on CE while those were not found on HPLC. Thus, the elevated HbA 2 measured by CE can be used as a screening parameter for differentiating the homozygote of Hb Tak and HbD-Punjab from the compound heterozygote of these hemoglobinopathies and β-thalassemia.

  2. Quantitative Trait Loci Influencing Hb F Levels in Southern Thai Hb E (HBB: c.79G>A) Heterozygotes.

    Science.gov (United States)

    Kesornsit, Aumpika; Jeenduang, Nutjaree; Horpet, Dararat; Plyduang, Thunyaluk; Nuinoon, Manit

    2018-01-01

    Variation of fetal hemoglobin (Hb F) expression in heterozygous Hb E (HBB: c.79G>A) individuals is associated with several genetic modifiers and not well understood. This study was undertaken in order to determine the effect of single nucleotide polymorphisms (SNPs), including XmnI G γ (rs7482144), rs766432 on the BCL11A gene and rs9376074 on the HBS1L gene, on Hb F levels in Southern Thai heterozygous Hb E individuals. A total of 97 Southern Thai subjects carrying heterozygous Hb E were selected for the hematological study. After excluding the samples with α-thalassemia (α-thal) interaction or moderate anemia, because both conditions can affect the hematological parameters, the remaining 74 samples were submitted to SNP analysis. Hematological parameters were measured using an automated hematology analyzer and high performance liquid chromatography (HPLC). The results show that rs766432 was strongly associated with increased Hb F levels and rs7482144 was associated with Hb F levels in each subgroup (genotype) of rs766432. This study suggested that the BCL11A locus has a major effect on Hb F levels compared with the XmnI polymorphism in Hb E heterozygotes. This association of Hb F levels with SNPs is useful for the interpretation of hemoglobin (Hb) typing in heterozygous Hb E samples with high Hb F levels. Future research will need to address the better understanding of the mechanisms of the SNPs that regulate Hb F production without stress erythropoiesis in Hb E heterozygotes.

  3. Drugs affecting HbA1c levels

    Directory of Open Access Journals (Sweden)

    Ranjit Unnikrishnan

    2012-01-01

    Full Text Available Glycated hemoglobin (HbA1c is an important indicator of glycemic control in diabetes mellitus, based on which important diagnostic and therapeutic decisions are routinely made. However, there are several situations in which the level of HbA1c may not faithfully reflect the glycemic control in a given patient. Important among these is the use of certain non-diabetic medications, which can affect the HbA1c levels in different ways. This review focuses on the non-diabetic medications which can inappropriately raise or lower the HbA1c levels, and the postulated mechanisms for the same.

  4. Co-inheritance of α0 -thalassemia elevates Hb A2 level in homozygous Hb E: Diagnostic implications.

    Science.gov (United States)

    Singha, K; Srivorakun, H; Fucharoen, G; Fucharoen, S

    2017-10-01

    Differentiation of homozygous hemoglobin (Hb) E with and without α 0 -thalassemia is subtle on routine hematological ground. We examined in a large cohort of homozygous Hb E if the level of Hb A 2 is helpful. A total of 592 subjects with homozygous Hb E were recruited from ongoing thalassemia screening program. Additionally, five couples at risk of having fetuses with Hb Bart's hydrops fetalis who were homozygous Hb E were also investigated. Hb analysis was performed using capillary electrophoresis system. Globin genotypes were defined by DNA analysis. Subjects were classified into four groups including pure homozygous Hb E (n=532), homozygous Hb E/α 0 -thalassemia (n=48), Hb Constant Spring EE Bart's disease (n=8), and Hb EE Bart's disease (n=4). The levels of Hb A 2 were found, respectively, to be 4.97±0.69, 6.64±1.02, 4.86±0.87, and 7.60±1.04%. Among five couples at risk, α 0 -thalassemia was identified in three subjects with Hb A 2 >6.0%. Increased Hb A 2 level is a useful marker for differentiation of homozygous Hb E with and without α 0 -thalassemia. This should lead to a significant reduction in number of referral cases of homozygous Hb E for molecular testing of α 0 -thalassemia in routine practice. © 2017 John Wiley & Sons Ltd.

  5. Effects of α-Thalassemia on HbA1c Measurement.

    Science.gov (United States)

    Xu, Anping; Ji, Ling; Chen, Weidong; Xia, Yong; Zhou, Yu

    2016-11-01

    α-Thalassemia is a benign condition that is often present in patients with diabetes mellitus. Here, we evaluated the effects of different genotypes α-thalassemia on HbA 1c measurement. A total of 189 samples from nondiabetic patients were analyzed. HbA 1c analysis was performed by ion-exchange high-performance liquid chromatography, boronate affinity HPLC, immunoassay, and capillary electrophoresis. Fasting glucose, fructosamin, and HbA 2 were also performed. All samples were confirmed by genotyping for thalassemia. In patients with two or three functional α-genes, HbA 1c values were not significantly different from those of controls (P > 0.05); however, in individuals with α-thalassemia with one functional α-gene (i.e., HbH disease), HbA 1c levels were significantly different from those of controls (P 0.05). In this study, HbA 1c values in samples from individuals with two or three functional α-genes basically reflected the normal mean blood glucose level, while those in samples from individuals with one functional α-gene did not. © 2016 Wiley Periodicals, Inc.

  6. Trajectories of HbA1c Levels in Children and Youth with Type 1 Diabetes

    Science.gov (United States)

    Pinhas-Hamiel, Orit; Hamiel, Uri; Boyko, Valentina; Graph-Barel, Chana; Reichman, Brian; Lerner-Geva, Liat

    2014-01-01

    Purpose To illustrate the distribution of Hemoglobin A1c (HbA1c) levels according to age and gender among children, adolescents and youth with type 1 diabetes (T1DM). Methods Consecutive HbA1c measurements of 349 patients, aged 2 to 30 years with T1DM were obtained from 1995 through 2010. Measurement from patients diagnosed with celiac disease (n = 20), eating disorders (n = 41) and hemoglobinopathy (n = 1) were excluded. The study sample comprised 4815 measurements of HbA1c from 287 patients. Regression percentiles of HbA1c were calculated as a function of age and gender by the quantile regression method using the SAS procedure QUANTREG. Results Crude percentiles of HbA1c as a function of age and gender, and the modeled curves produced using quantile regression showed good concordance. The curves show a decline in HbA1c levels from age 2 to 4 years at each percentile. Thereafter, there is a gradual increase during the prepubertal years with a peak at ages 12 to 14 years. HbA1c levels subsequently decline to the lowest values in the third decade. Curves of females and males followed closely, with females having HbA1c levels about 0.1% (1.1 mmol/mol) higher in the 25th 50th and 75th percentiles. Conclusion We constructed age-specific distribution curves for HbA1c levels for patients with T1DM. These percentiles may be used to demonstrate the individual patient's measurements longitudinally compared with age-matched patients. PMID:25275650

  7. HbA2 measurements in β-thalassemia and in other conditions

    Directory of Open Access Journals (Sweden)

    Giovanni Ivaldi

    2014-09-01

    Full Text Available Quite a few papers have been written on the significance of elevated hemoglobin (Hb A2 as a parameter for the diagnosis of β-thalassemia trait, on the cutoff values to be used in diagnostics and on the significance and effects of factors reducing or elevating the expression of HbA2 and last but not least on the need for reliable measurement methods and precise calibrations with accurate standards. However, little has been published on the causes that elevate or reduce the HbA2 levels in β- and a-thalassemia and in other conditions. For a better understanding of the value of a precise measurement of this parameter we summarize and elucidate in this review the direct and indirect mechanisms that cause the variations in HbA2 expression and that influence the value of this parameter in particular conditions. We conclude by explaining the advantages and disadvantages of trusting on a precise measurement in the complete diagnostic contest.

  8. Measurements of red cell deformability and hydration reflect HbF and HbA2 in blood from patients with sickle cell anemia.

    Science.gov (United States)

    Parrow, Nermi L; Tu, Hongbin; Nichols, James; Violet, Pierre-Christian; Pittman, Corinne A; Fitzhugh, Courtney; Fleming, Robert E; Mohandas, Narla; Tisdale, John F; Levine, Mark

    2017-06-01

    Decreased erythrocyte deformability, as measured by ektacytometry, may be associated with disease severity in sickle cell anemia (SCA). Heterogeneous populations of rigid and deformable cells in SCA blood result in distortions of diffraction pattern measurements that correlate with the concentration of hemoglobin S (HbS) and the percentage of irreversibly sickled cells. We hypothesize that red cell heterogeneity, as well as deformability, will also be influenced by the concentration of alternative hemoglobins such as fetal hemoglobin (HbF) and the adult variant, HbA 2 . To test this hypothesis, we investigate the relationship between diffraction pattern distortion, osmotic gradient ektacytometry parameters, and the hemoglobin composition of SCA blood. We observe a correlation between the extent of diffraction pattern distortions and percentage of HbF and HbA 2 . Osmotic gradient ektacytometry data indicate that minimum elongation in the hypotonic region is positively correlated with HbF, as is the osmolality at which it occurs. The osmolality at both minimum and maximum elongation is inversely correlated with HbS and HbA 2 . These data suggest that HbF may effectively improve surface-to-volume ratio and osmotic fragility in SCA erythrocytes. HbA 2 may be relatively ineffective in improving these characteristics or cellular hydration at the levels found in this patient cohort. Copyright © 2017. Published by Elsevier Inc.

  9. Predictors of HbA1c levels in patients initiating metformin.

    Science.gov (United States)

    Martono, Doti P; Hak, Eelko; Lambers Heerspink, Hiddo; Wilffert, Bob; Denig, Petra

    2016-12-01

    The aim was to assess demographic and clinical factors as predictors of short (6 months) and long term (18 months) HbA1c levels in diabetes patients initiating metformin treatment. We conducted a cohort study including type 2 diabetes patients who received their first metformin prescription between 2007 and 2013 in the Groningen Initiative to Analyze Type 2 Diabetes Treatment (GIANTT) database. The primary outcome was HbA1c level at follow-up adjusted for baseline HbA1c; the secondary outcome was failing to achieve the target HbA1c level of 53 mmol/mol. Associations were analyzed by linear and logistic regression. Multiple imputation was used for missing data. Additional analyses stratified by dose and adherence level were conducted. The cohort included 6050 patients initiating metformin. Baseline HbA1c at target consistently predicted better HbA1c outcomes. Longer diabetes duration and lower total cholesterol level at baseline were predictors for higher HbA1c levels at 6 months. At 18 months, cholesterol level was not a predictor. Longer diabetes duration was also associated with not achieving the target HbA1c at follow-up. The association for longer diabetes duration was especially seen in patients starting on low dose treatment. No consistent associations were found for comorbidity and comedication. Diabetes duration was a relevant predictor of HbA1c levels after 6 and 18 months of follow-up in patients initiating metformin treatment. Given the study design, no causal inference can be made. Our study suggests that prompt treatment intensification may be needed in patients who have a longer diabetes duration at treatment initiation.

  10. Measurement of HbA1c and HbA2 by Capillarys 2 Flex Piercing HbA1c programme for simultaneous management of diabetes and screening for thalassemia.

    Science.gov (United States)

    Ke, Peifeng; Liu, Jiawei; Chao, Yan; Wu, Xiaobin; Xiong, Yujuan; Lin, Li; Wan, Zemin; Wu, Xinzhong; Xu, Jianhua; Zhuang, Junhua; Huang, Xianzhang

    2017-10-01

    Thalassemia could interfere with some assays for haemoglobin A 1c (HbA 1c ) measurement, therefore, it is useful to be able to screen for thalassemia while measuring HbA 1c . We used Capillarys 2 Flex Piercing (Capillarys 2FP) HbA 1c programme to simultaneously measure HbA 1c and screen for thalassemia. Samples from 498 normal controls and 175 thalassemia patients were analysed by Capillarys 2FP HbA 1c programme (Sebia, France). For method comparison, HbA 1c was quantified by Premier Hb9210 (Trinity Biotech, Ireland) in 98 thalassaemia patients samples. For verification, HbA 1c from eight thalassaemia patients was confirmed by IFCC reference method. Among 98 thalassaemia samples, Capillarys 2FP did not provide an HbA 1c result in three samples with HbH due to the overlapping of HbBart's with HbA 1c fraction; for the remaining 95 thalassaemia samples, Bland-Altman plot showed 0.00 ± 0.35% absolute bias between two systems, and a significant positive bias above 7% was observed only in two HbH samples. The HbA 1c values obtained by Capillarys 2FP were consistent with the IFCC targets (relative bias below ± 6%) in all of the eight samples tested by both methods. For screening samples with alpha (α-) thalassaemia silent/trait or beta (β-) thalassemia trait, the optimal HbA 2 cut-off values were ≤ 2.2% and > 2.8%, respectively. Our results demonstrated the Capillarys 2FP HbA 1c system could report an accurate HbA 1c value in thalassemia silent/trait, and HbA 2 value (≤ 2.2% for α-thalassaemia silent/trait and > 2.8% for β-thalassemia trait) and abnormal bands (HbH and/or HbBart's for HbH disease, HbF for β-thalassemia) may provide valuable information for screening.

  11. Prevalence and predictors of the sub-target Hb level in children on dialysis

    DEFF Research Database (Denmark)

    van Stralen, Karlijn J; Krischock, Leah; Schaefer, Franz

    2012-01-01

    Anaemia is a common and potentially treatable co-morbidity of end-stage renal disease. We aimed to determine the prevalence of the sub-target haemoglobin (Hb) level among European children on dialysis and to identify factors associated with a low Hb level.......Anaemia is a common and potentially treatable co-morbidity of end-stage renal disease. We aimed to determine the prevalence of the sub-target haemoglobin (Hb) level among European children on dialysis and to identify factors associated with a low Hb level....

  12. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes.

    Science.gov (United States)

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L; Temple, Rosemary; Bilous, Rudolf; Mathiesen, Elisabeth R; Murphy, Helen R; Scott, Eleanor M

    2017-04-01

    This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA 1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA 1c measurements are applicable to pregnant women with diabetes. CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5-7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA 1c measure. In total, 688 average glucose-HbA 1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA 1c . There was a strong association between HbA 1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA 1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA 1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4-7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA 1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week. The HbA 1c -average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care.

  13. HbA1c values calculated from blood glucose levels using truncated Fourier series and implementation in standard SQL database language.

    Science.gov (United States)

    Temsch, W; Luger, A; Riedl, M

    2008-01-01

    This article presents a mathematical model to calculate HbA1c values based on self-measured blood glucose and past HbA1c levels, thereby enabling patients to monitor diabetes therapy between scheduled checkups. This method could help physicians to make treatment decisions if implemented in a system where glucose data are transferred to a remote server. The method, however, cannot replace HbA1c measurements; past HbA1c values are needed to gauge the method. The mathematical model of HbA1c formation was developed based on biochemical principles. Unlike an existing HbA1c formula, the new model respects the decreasing contribution of older glucose levels to current HbA1c values. About 12 standard SQL statements embedded in a php program were used to perform Fourier transform. Regression analysis was used to gauge results with previous HbA1c values. The method can be readily implemented in any SQL database. The predicted HbA1c values thus obtained were in accordance with measured values. They also matched the results of the HbA1c formula in the elevated range. By contrast, the formula was too "optimistic" in the range of better glycemic control. Individual analysis of two subjects improved the accuracy of values and reflected the bias introduced by different glucometers and individual measurement habits.

  14. Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study.

    Science.gov (United States)

    Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R

    2015-10-01

    Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.

  15. Serum levels of antioxidant vitamins in foetal haemoglobin (HbF ...

    African Journals Online (AJOL)

    Background: sickle cell anaemia (SCA) is one of the commonest health problems of Nigerian children. Method: The serum levels of antioxidant vitamins A (retinol), C (ascorbic acid) and E (alpha-tocopherol) were determined in foetal haemogbobin persistent sickle cell anaemic (Hb SS + F), sickle cell anaemic (Hb SS) and ...

  16. GENETIC FACTORS INFLUENCING HEMOGLOBIN F LEVEL IN β-THALASSEMIA/HB E DISEASE.

    Science.gov (United States)

    Ruangrai, Waraporn; Jindadamrongwech, Sumalee

    2016-01-01

    Genetic factors influencing Hb F content in adult red blood cells include β-thalassemia genotypes, co-inheritance of α-thalassemia traits and single nucleotide polymorphisms (SNPs). Genotyping of α- and β-thalassemia and five SNPs in β-globin gene cluster previously identified in genome-wide association studies as being markers of elevated Hb F in β-thalassemia were performed in 81 subjects diagnosed with β-thalassemia/Hb E. Hb F levels are higher (0.9-7.1 g/dl) in subjects (n = 57) with the severe compared to mild β-thalassemia (0.8-2.5 g/ dl) (n = 4) genotypes, and are similarly low (0.7-3.5 g/dl) in those (n = 15) with α-thalassemia co-inheritance. Hb F levels in non-thalassemia controls (n = 150) range from 0 to 0.15 g/dl. The presence of homozygous minor alleles of the 5 SNPs are significant indicators of β-thalassemia/Hb E individuals with high Hb F (> 4 g/dl), independent of their thalassemia genotypes. Given that re-activation of γ-globin genes leads to amelioration of β-thalassemia severity, understanding how genetic factors up-regulate Hb F production may lead to possible therapeutic interventions, genetically or pharmacologically, of this debilitating disease in the not too distant future.

  17. HbA1c levels in individuals heterozygous for hemoglobin variants.

    Science.gov (United States)

    Tavares, Ricardo Silva; Souza, Fábio Oliveira de; Francescantonio, Isabel Cristina Carvalho Medeiros; Soares, Weslley Carvalho; Mesquita, Mauro Meira

    2017-04-01

    To evaluate the levels of glycated hemoglobin (HbA1c) in patients heterozygous for hemoglobin variants and compare the results of this test with those of a control group. This was an experimental study based on the comparison of HbA1c tests in two different populations, with a test group represented by individuals heterozygous for hemoglobin variants (AS and AC) and a control group consisting of people with electrophoretic profile AA. The two populations were required to meet the following inclusion criteria: Normal levels of fasting glucose, hemoglobin, urea and triglycerides, bilirubin > 20 mg/dL and non-use of acetylsalicylic acid. 50 heterozygous subjects and 50 controls were evaluated between August 2013 and May 2014. The comparison of HbA1c levels between heterozygous individuals and control subjects was performed based on standard deviation, mean and G-Test. The study assessed a test group and a control group, both with 39 adults and 11 children. The mean among heterozygous adults for HbA1c was 5.0%, while the control group showed a rate of 5.74%. Heterozygous children presented mean HbA1c at 5.11%, while the controls were at 5.78%. G-Test yielded p=0.93 for children and p=0.89 for adults. Our study evaluated HbA1c using ion exchange chromatography resins, and the patients heterozygous for hemoglobin variants showed no significant difference from the control group.

  18. Effect of ethnicity on HbA1c levels in individuals without diabetes: Systematic review and meta-analysis

    Science.gov (United States)

    Freitas, Priscila Aparecida Correa; Gross, Jorge Luiz

    2017-01-01

    Aims/Hypothesis Disparities in HbA1c levels have been observed among ethnic groups. Most studies were performed in patients with diabetes mellitus (DM), which may interfere with results due to the high variability of glucose levels. We conducted a systematic review and meta-analysis to investigate the effect of ethnicity on HbA1c levels in individuals without DM. Methods This is a systematic review with meta-analysis. We searched MEDLINE and EMBASE up to September 2016. Studies published after 1996, performed in adults without DM, reporting HbA1c results measured by certified/standardized methods were included. A random effects model was used and the effect size was presented as weighted HbA1c mean difference (95% CI) between different ethnicities as compared to White ethnicity. Results Twelve studies met the inclusion criteria, totalling data from 49,238 individuals. There were significant differences between HbA1c levels in Blacks [0.26% (2.8 mmol/mol); 95% CI 0.18 to 0.33 (2.0 to 3.6), p HbA1c values are higher in Blacks, Asians, and Latinos when compared to White persons. Although small, these differences might have impact on the use of a sole HbA1c point to diagnose DM in all ethnic populations. PMID:28192447

  19. A Family with γ-Thalassemia and High Hb A2 Levels.

    Science.gov (United States)

    Parmeggiani, Giulia; Gualandi, Francesca; Selvatici, Rita; Rimessi, Paola; Bigoni, Stefania; Taddei Masieri, Marina; Dolcini, Bernadetta; Venturoli, Anna; Cappabianca, Maria P; Ferlini, Alessandra; Ravani, Anna

    2016-06-01

    We describe a family carrying a γ-globin gene deletion associated with an increase of Hb A2 level beyond the normal range. The family included the proband, his sister and their father, all with increased Hb A2 and normal Hb F levels. The proband and his sister showed borderline values of mean corpuscular volume (MCV) and reduced values of mean corpuscular hemoglobin (Hb) (MCH). The proband was referred to our Medical Genetics Service for preconception counseling together with his partner, a typical β-thalassemia (β-thal) carrier. The results were negative for the most frequent α-thalassemia (α-thal) mutations, and had no significant sequence variations of the coding sequences and promoter of the β- and δ-globin genes. Quantitative analysis by multiplex ligation-dependent probe amplification (MPLA) of the β-globin gene cluster detected a heterozygous deletion, ranging between 2.1 and 4.7 kb, in the proband, his sister and the father. The deletion involved the (G)γ gene and (G)γ-(A)γ intergenic region, whereas the 3' region of the (A)γ gene was preserved. A subsequent gap-polymerase chain reaction (gap-PCR) showed that a hybrid (GA)γ fusion gene was present. The deletion segregated with the elevation of Hb A2. The MLPA analysis of the β-globin gene cluster in 150 control alleles excluded a common polymorphism. Despite stronger evidence being needed, the described family suggests a possible role of this γ-globin gene deletion in contributing to Hb A2 elevation, possibly by altering the transcription regulation of the cluster. We propose γ-globin gene dosage analysis to be performed in patients with unexplained elevated Hb A2 levels.

  20. Beyond HbA1c.

    Science.gov (United States)

    Bloomgarden, Zachary

    2017-12-01

    It can scarcely be denied that the supreme goal of all theory is to make the irreducible basic elements as simple and as few as possible without having to surrender the adequate representation of a single datum of experience. The diaTribe Foundation convened a meeting on the topic of glycemic outcomes beyond HbA1c on 21 July 2017, in Bethesda (MD, USA), focusing on potential uses of continuous glucose monitoring (CGM). Understanding patterns of glycemia in people with diabetes has long been a focus of approaches to improving treatment, and over the past few years this has become an available modality for clinical practice. Glucose levels are not the only biologic parameters affecting HbA1c levels; HbA1c changes with anemia or, more subtly, with changes in rates of erythrocyte turnover not reflected in hemoglobin levels outside the normal range. Renal disease often is associated with lower HbA1c than would be predicted based on an individual's glycemic levels. Furthermore, HbA1c levels tend to increase with age and are higher in some ethnic groups; for example, people of African ethnicity have higher HbA1c levels than people of Northern European descent. Indeed, we have argued that even as a measure of mean glycemia HbA1c is inherently imprecise. Overall, for some 20% of people with diabetes, HbA1c levels are substantially higher, or substantially lower, than those that would be predicted from mean blood glucose levels. If one recognizes that HbA1c is, at best, a partial measure of mean glycemic exposure, one must surely accept that HbA1c does not reflect variability within a day, from day to day, and from period to period. Many glucose-lowering medicines, particularly the sulfonylureas and insulin, cause hypoglycemia, with consequent negative effects on quality of life and patient-reported outcomes, as well as association with weight gain and adverse macrovascular outcome; hypoglycemia will, of course, not be captured by HbA1c measurement. Based on these

  1. A method comparison study between two hemoglobinometer models (Hemocue Hb 301 and Hb 201+) to measure hemoglobin concentrations and estimate anemia prevalence among women in Preah Vihear, Cambodia.

    Science.gov (United States)

    Rappaport, A I; Karakochuk, C D; Whitfield, K C; Kheang, K M; Green, T J

    2017-02-01

    Hemoglobin (Hb) concentration is often measured in global health and nutrition surveys to determine anemia prevalence using a portable hemoglobinometer such as the Hemocue® Hb 201+. More recently, a newer model was released (Hemocue Hb 301) utilizing slightly different methods to measure Hb as compared to the older model. The objective was to measure bias and concordance between Hb concentrations using the Hemocue Hb 301 and Hb 201+ models in a rural field setting. Hemoglobin (Hb) concentration was measured using one finger prick of blood (approximately 10 μL) from 175 Cambodian women (18-49 years) using three Hemocue Hb 201+ and three Hb 301 machines. Bias and concordance were measured and plotted. Overall, mean ± SD Hb concentration was 116 ± 13 g/L using the Hb 201+ and 118 ± 12 g/L using the Hb 301; and anemia prevalence (Hb < 120 g/L) was 58% (n = 102) and 58% (n = 101), respectively. Overall bias ± SD was 2.0 ± 10.5 g/L and concordance (95% CI) was 0.63 (0.54, 0.72). Despite the 2 g/L bias detected between models, anemia prevalence was very similar in both models. The two models measured anemia prevalence comparably in this population of women in rural Cambodia. © 2016 John Wiley & Sons Ltd.

  2. The Hb E (HBB: c.79G>A), Mean Corpuscular Volume, Mean Corpuscular Hemoglobin Cutoff Points in Double Heterozygous Hb E/- -SEA α-Thalassemia-1 Carriers are Dependent on Hemoglobin Levels.

    Science.gov (United States)

    Leckngam, Prapapun; Limweeraprajak, Ektong; Kiewkarnkha, Tiemjan; Tatu, Thanusak

    2017-01-01

    Identifying double heterozygosities in Hb E (HBB: c.79 G>A)/- - SEA (Southeast Asian) (α-thalassemia-1) (α-thal-1) in patients first diagnosed as carrying Hb E is important in thalassemia control. Low Hb E, mean corpuscular volume (MCV) and mean corpuscular hemoglobin (Hb) (MCH) levels have been observed in this double heterozygosity. However, the cutoff points of these parameters have never been systematically established. Here, we analyzed Hb E and red blood cell (RBC) parameters in 372 Hb E patients grouped by Hb levels, by the status of - - SEA and -α 3.7 (α-thal-2; rightward) deletions, to establish the cutoff points. Then, the established cutoff points were evaluated in 184 Hb E patients. It was found that the cutoff points of Hb E, MCV, MCH were significantly dependent on the Hb levels. In the group having Hb levels Hb E, MCV and MCH were 21.2%, 64.9 fL and 21.0 pg, respectively, and were 25.6%, 72.8 fL and 23.9 pg, respectively, in the group having Hb levels 10.0-11.9 g/dL. Finally, in the group having Hb levels ≥12.0 g/dL, the cutoff points of Hb E, MCV and MCH were 27.1%, 76.7 fL and 25.3 pg, respectively. Thus, to screen for the double heterozygous Hb E/- - SEA anomaly in patients initially diagnosed as carrying Hb E, the Hb levels must be taken into account in choosing the suitable cutoff points of these three parameters.

  3. HbA2 levels in β-thalassaemia carriers with the Filipino β0-deletion: are the levels higher than what is found with non-deletional forms of β0-thalassaemia?

    Science.gov (United States)

    George, E; Teh, Lai Kuan; Tan, Jama; Lai, Mei I; Wong, Lily

    2013-01-01

    Classical carriers of β-thalassaemia are identified by a raised HbA2 level. Earlier studies indicated that the Filipino β-deletion has high raised HbA2 levels. The introduction of automated high performance liquid chromatography (HPLC) for thalassaemia screening is an important advance in technology for haematology laboratories. The BioRad Variant II Hb analyser is a common instrument used to quantify HbA2 levels in thalassaemia screening. This study aimed to determine HbA2 levels in carriers of Filipino β-mutation using the BioRad Variant II Hb analyser. The Filipino β-deletion was identified using gap-polymerase chain reaction (PCR) in the parents of transfusion dependent β-thalassaemia patients who were homozygous for the Filipino β-deletion in the indigenous population of Sabah, Malaysia. Hb subtypes were quantified on the BioRad Variant II Hb analyser. Concurrent α-thalassaemia was identified by multiplex gap-PCR for deletions and amplification refractory mutation system (ARMS)-PCR for non-deletional mutations. The mean HbA2 level for Filipino β-thalassaemia trait was 5.9 ± 0.47 and with coinheritance of α-thalassaemia was 6.3 ± 0.44 (-α heterozygous) and 6.7 ± 0.36 (-α homozygous). The HbA2 levels were all >4% in keeping with the findings of classical β-thalassaemia trait and significantly higher than levels seen in non-deletional forms of β-thalassaemia. The HbA2 level measured on the BioRad Variant II Hb analyser was lower than the level in the first description of the Filipino β-thalassaemia. β-thalassaemia trait with coinheritance of α-thalassaemia (-α) is associated with significantly higher HbA2 level.

  4. HbA1c measurements from dried blood spots : validation and patient satisfaction

    NARCIS (Netherlands)

    Fokkema, Margaretha; Bakker, Andries J; de Boer, Fokje; Kooistra, Jeltsje; de Vries, Sifra; Wolthuis, Albert

    2009-01-01

    Background: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood. Methods: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper

  5. Effects of hemoglobin variants HbJ Bangkok, HbE, HbG Taipei, and HbH on analysis of glycated hemoglobin via ion-exchange high-performance liquid chromatography.

    Science.gov (United States)

    Zhang, Xiu-Ming; Wen, Dong-Mei; Xu, Sheng-Nan; Suo, Ming-Huan; Chen, Ya-Qiong

    2018-01-01

    To explore the effects of HbJ Bangkok, HbE, HbG Taipei, and α-thalassemia HbH on the results of HbA1c assessment using ion-exchange high-performance liquid chromatography (IE-HPLC). We enrolled five patients in which the results of the IE-HPLC HbA1c assay were inconsistent with the average levels of FBG. We performed hemoglobin capillary (Hb) electrophoresis using whole-blood samples. We also sequenced the genes encoding Hb using dideoxy-mediated chain termination and analyzed HbA1c using borate affinity HPLC (BA-HPLC) and turbidimetric inhibition immunoassay (TINIA). Two patients had the HbJ Bangkok variant. Hb genotypes of these patients were β 41-42 /β J Bangkok and β N /β J Bangkok , and the content of HbJ Bangkok was 93.9% and 52.4%, respectively. The remaining three patients had the following: HbE (β N /β E Hb genotype, 23.6% HbE content), HbG Taipei (β N /β G Taipei Hb genotype, 39.4% HbG Taipei content), and α-thalassemia HbH (6.1% HbH content, 2.8% Hb Bart's content). In the patients with β-thalassemia and HbJ Bangkok variants, the presence of the variants interfered with the results of HbA1c analyses using IE-HPLC and TINIA; in the remaining four patients, there was interference with the results of HbA1c IE-HPLC but not with the TINIA assay. There was no interference with BA-HPLC HbA1c results. HbJ Bangkok, HbE, HbG Taipei Hb, and α-thalassemia HbH disease cause varying degrees of interference with the analysis of HbA1c using IE-HPLC. In these patients, we suggest using methods free from such interference for the analysis of HbA1c and other indicators to monitor blood glucose levels. © 2017 Wiley Periodicals, Inc.

  6. Association of plasma PCB levels and HbA1c concentration in Iran.

    Science.gov (United States)

    Eftekhari, Sahar; Aminian, Omid; Moinfar, Zeinab; Schettgen, Thomas; Kaifie, Andrea; Felten, Michael; Kraus, Thomas; Esser, André

    2018-01-01

    The rapid increase in prevalence of diabetes mellitus over the last decades warrants more attention to the effects of environmental and occupational exposures on glucose metabolism. Our study aimed to assess the association between the plasma levels of various congeners of polychlorinated biphenyls (PCBs) and the serum concentration of glycated haemoglobin (HbA1c). Our study population consisted of 140 Iranian adults from seven different occupational groups and a group of non-occupationally exposed female participants. The plasma concentration of PCBs were determined at the laboratory of occupational toxicology at RWTH Aachen University, Germany. We considered an HbA1c concentration of 5.7% and more as indicating a disturbed glucose metabolism. Logistic regression was used to assess the association between quartiles of concentrations of PCB congeners and serum HbA1c. Participants with an increased HbA1c value had higher plasma levels of PCB 138, 153, 180 and the PCB sum, although this association was statistically not significant. There was no significant difference between the levels of PCB 138, 153, 180, the sum of these congeners, and PCB 118 in their quartiles when comparing with HbA1c concentrations. For our cohort, we could not demonstrate a significant association between PCB and HbA1c concentrations indicating a disturbance of glucose metabolism.

  7. HB-Line Material Control and Accountability Measurements at SRS

    International Nuclear Information System (INIS)

    Casella, V.R.

    2003-01-01

    Presently, HB-Line work at the Savannah River Site consists primarily of the stabilization and packaging of nuclear materials for storage and the characterization of materials for disposition in H-Area. In order to ensure compliance with Material Control and Accountability (MC and A) Regulations, accountability measurements are performed throughout the HB-Line processes. Accountability measurements are used to keep track of the nuclear material inventory by constantly updating the amount of material in the MBAs (Material Balance Area) and sub-MBAs. This is done by subtracting the amount of accountable material that is added to a process and by adding the amount of accountable material that is put back in storage. A Physical Inventory is taken and compared to the ''Book Value'' listed in the Nuclear Material Accounting System. The difference (BPID) in the Book Inventory minus the Physical Inventory of a sub-account for bulk material must agree within the measurement errors combined in quadrature to provide assurance that nuclear material is accounted for. This work provides an overview of HB-Line processes and accountability measurements. The Scrap Recovery Line and Neptunium-237/Plutonium-239 Oxide Line are described and sampling and analyses for Phase II are provided. Recommendations for improvements are provided to improve efficiency and cost effectiveness

  8. Defining a glycated haemoglobin (HbA1c) level that predicts increased risk of penile implant infection.

    Science.gov (United States)

    Habous, Mohamad; Tal, Raanan; Tealab, Alaa; Soliman, Tarek; Nassar, Mohammed; Mekawi, Zenhom; Mahmoud, Saad; Abdelwahab, Osama; Elkhouly, Mohamed; Kamr, Hatem; Remeah, Abdallah; Binsaleh, Saleh; Ralph, David; Mulhall, John

    2018-02-01

    To re-evaluate the role of diabetes mellitus (DM) as a risk factor for penile implant infection by exploring the association between glycated haemoglobin (HbA1c) levels and penile implant infection rates and to define a threshold value that predicts implant infection. We conducted a multicentre prospective study including all patients undergoing penile implant surgery between 2009 and 2015. Preoperative, perioperative and postoperative management were identical for the entire cohort. Univariate analysis was performed to define predictors of implant infection. The HbA1c levels were analysed as continuous variables and sequential analysis was conducted using 0.5% increments to define a threshold level predicting implant infection. Multivariable analysis was performed with the following factors entered in the model: DM, HbA1C level, patient age, implant type, number of vascular risk factors (VRFs), presence of Peyronie's disease (PD), body mass index (BMI), and surgeon volume. A receiver operating characteristic (ROC) curve was generated to define the optimal HbA1C threshold for infection prediction. In all, 902 implant procedures were performed over the study period. The mean patient age was 56.6 years. The mean HbA1c level was 8.0%, with 81% of men having a HbA1c level of >6%. In all, 685 (76%) implants were malleable and 217 (24%) were inflatable devices; 302 (33.5%) patients also had a diagnosis of PD. The overall infection rate was 8.9% (80/902). Patients who had implant infection had significantly higher mean HbA1c levels, 9.5% vs 7.8% (P HbA1c level, we found infection rates were: 1.3% with HbA1c level of 9.5% (P HbA1c level, whilst a high-volume surgeon had a protective effect and was associated with a reduced infection risk. Using ROC analysis, we determined that a HbA1c threshold level of 8.5% predicted infection with a sensitivity of 80% and a specificity of 65%. Uncontrolled DM is associated with increased risk of infection after penile implant surgery

  9. HB-Line Plutonium Oxide Data Collection Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, R. [Savannah River Nuclear Solutions; Varble, J. [Savannah River Nuclear Solutions; Jordan, J. [Savannah River Nuclear Solutions

    2015-05-26

    HB-Line and H-Canyon will handle and process plutonium material to produce plutonium oxide for feed to the Mixed Oxide Fuel Fabrication Facility (MFFF). However, the plutonium oxide product will not be transferred to the MFFF directly from HB-Line until it is packaged into a qualified DOE-STD-3013-2012 container. In the interim, HB-Line will load plutonium oxide into an inner, filtered can. The inner can will be placed in a filtered bag, which will be loaded into a filtered outer can. The outer can will be loaded into a certified 9975 with getter assembly in compliance with onsite transportation requirement, for subsequent storage and transfer to the K-Area Complex (KAC). After DOE-STD-3013-2012 container packaging capabilities are established, the product will be returned to HB-Line to be packaged into a qualified DOE-STD-3013-2012 container. To support the transfer of plutonium oxide to KAC and then eventually to MFFF, various material and packaging data will have to be collected and retained. In addition, data from initial HB-Line processing operations will be needed to support future DOE-STD-3013-2012 qualification as amended by the HB-Line DOE Standard equivalency. As production increases, the volume of data to collect will increase. The HB-Line data collected will be in the form of paper copies and electronic media. Paper copy data will, at a minimum, consist of facility procedures, nonconformance reports (NCRs), and DCS print outs. Electronic data will be in the form of Adobe portable document formats (PDFs). Collecting all the required data for each plutonium oxide can will be no small effort for HB-Line, and will become more challenging once the maximum annual oxide production throughput is achieved due to the sheer volume of data to be collected. The majority of the data collected will be in the form of facility procedures, DCS print outs, and laboratory results. To facilitate complete collection of this data, a traveler form will be developed which

  10. Measurement of HbA1c in Gingival Crevicular Blood Using a High Pressure Liquid Chromatography Procedure

    Science.gov (United States)

    Pesce, Michael A.; Strauss, Shiela M.; Rosedale, Mary; Netterwald, Jane; Wang, Hangli

    2016-01-01

    Objectives To validate an ion exchange high-pressure liquid chromatography (HPLC) method for measuring glycated hemoglobin (HbA1c) in gingival crevicular blood (GCB) spotted on filter paper, for use in screening dental patients for diabetes. Methods We collected the GCB specimens for this study from the oral cavities of patients during dental visits, using rigorous strategies to obtain GCB that was as free of debris as possible. The analytical performance of the HPLC method was determined by measuring the precision, linearity, carryover, stability of HbA1c in GCB, and correlation of HbA1c results in GCB specimens with finger-stick blood (FSB) specimens spotted on filter paper. Results The coefficients of variation (CVs) for the inter- and intrarun precision of the method were less than 2.0%. Linearity ranged between 4.2% and 12.4%; carryover was less than 2.0%, and the stability of the specimen was 6 days at 4°C and as many as 14 days at −70°C. Linear regression analysis comparing the HbA1c results in GCB with FSB yielded a correlation coefficient of 0.993, a slope of 0.981, and an intercept of 0.13. The Bland-Altman plot showed no difference in the HbA1c results from the GCB and FSB specimens at normal, prediabetes, and diabetes HbA1c levels. Conclusion We validated an HPLC method for measuring HbA1c in GCB; this method can be used to screen dental patients for diabetes. PMID:26489673

  11. HbD Punjab/HbQ India compound heterozygosity: An unusual association.

    Directory of Open Access Journals (Sweden)

    Stacy Colaco

    2014-11-01

    Full Text Available Background: Haemoglobinopathies are the commonest hereditary disorders in India and pose a major health problem. Both beta thalassaemia and structural haemoglobin variants are relatively common in north western India. Here we report a 29 year old Sindhi female who was referred to us for a haemoglobinopathy work up and genetic counseling since her spouse was a classical beta thalassaemia carrier. Method: A complete blood count was done on an automated cell counter. Haemoglobin analysis was carried out using HPLC Variant Haemoglobin Testing System.  The cellulose acetate electrophoresis was carried out [pH 8.9]. Confirmation of mutations was done by automated DNA sequencing. Results: HPLC analysis showed four major peaks, HbA0, a peak in the HbD window, an unknown peak [retention time 4.74 minutes] and a peak in the HbC window. The HbA2 level was 2.2% and the HbF level was 0.7%.Cellulose acetate electrophoresis at alkaline pH, a slow moving band was seen at the HbS/D position along with a prominent band at the HbA2 position. DNA sequencing of the β and α genes showed presence of the 2 hemoglobin variants :Hb D [b 121GAA à CAA] and Hb Q [a 64 AAG à GAG]. The δ globin gene was normal. The additional peak in the HbC window was due to the formation of a heterodimer hybrid. Conclusion: Both HbD Punjab and HbQ India are relatively common in India but their co-inheritance has not been described in the country. This is the second report of compound heterozygosity for HbQ India/HbD Punjab haemoglobinopathy globally, and the first one from India.

  12. A new approach for the carbon monoxide (CO) exposure diagnosis: measurement of total CO in human blood versus carboxyhemoglobin (HbCO).

    Science.gov (United States)

    Varlet, Vincent; De Croutte, Emma Lagroy; Augsburger, Marc; Mangin, Patrice

    2013-07-01

    The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning. © 2013 American Academy of Forensic Sciences.

  13. How does CKD affect HbA1c?

    Science.gov (United States)

    Bloomgarden, Zachary; Handelsman, Yehuda

    2018-04-01

    HOW DOES CHRONIC KIDNEY DISEASE AFFECT HBA1C?: A number of factors determine HbA1c other than the level of glucose exposure alone. In an subset analysis of the Atherosclerosis Risk in Communities study of 941 diabetic people with varying degrees of chronic kidney disease (CKD), as well as 724 who did not have CKD, and mean age in the eighth decade, Jung et al. ask whether HbA1c is reliable as an indicator of glycemia in people with kidney disease (CKD) to the same degree as in those not having kidney disease, and, if not, whether measures of glycated serum proteins may be more useful. The only available measure of glycemia for comparison was a single fasting glucose level, and the authors acknowledge that this gives an incomplete measure, particularly in people with relatively mild diabetes, whose mean HbA1c was 6.4%, with most having levels of 7.5% or lower. In patients of this sort, postprandial glucose levels may better explain variations in mean HbA1c. Recognizing that the dataset may be limited, Jung et al. nevertheless give an intriguingly negative answer to the first question, of the reliability of HbA1c with kidney disease. Using Deming regression analysis, Jung et al. showed that the correlation between HbA1c and fasting glucose weakens as renal function worsens, and, moreover, that this appears particularly to be the case in people with anemia (hemoglobin men and women, respectively), confirming earlier observations. Among those diabetic people with neither anemia nor CKD, the correlation coefficient between HbA1c and fasting glucose was r = 0.70, compared with r = 0.35 among those with both anemia and very severe CKD (estimated glomerular filtration rate [eGFR] perform SMBG to more adequately interpret HbA1c results. © 2017 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  14. Current Status of HbA1c Biosensors

    Science.gov (United States)

    Lin, Hua; Yi, Jun

    2017-01-01

    Glycated hemoglobin (HbA1c) is formed via non-enzymatic glycosylation reactions at the α–amino group of βVal1 residues in the tetrameric Hb, and it can reflect the ambient glycemic level over the past two to three months. A variety of HbA1c detection methods, including chromatography, immunoassay, enzymatic measurement, electrochemical sensor and capillary electrophoresis have been developed and used in research laboratories and in clinics as well. In this review, we summarize the current status of HbA1c biosensors based on the recognition of the sugar moiety on the protein and also their applications in the whole blood sample measurements. PMID:28777351

  15. Molecular analysis of Hb Q-H disease and Hb Q-Hb E in a Singaporean family.

    Science.gov (United States)

    Tan, J; Tay, J S; Wong, Y C; Kham, S K; Bte Abd Aziz, N; Teo, S H; Wong, H B

    1995-01-01

    Hb Q (alpha 74Asp-His) results from a mutation in the alpha-gene such that abnormal alpha Q-chains are synthesized. The alpha Q-chains combine with the normal Beta A-chains to form abnormal Hb alpha 2Q beta 2A (Hb Q). Hb Q-H disease is rare, and has been reported only in the Chinese. We report here a Chinese family, were the mother diagnosed with Hb Q-H disease and the father with Hb E heterozygosity and a child with Hb Q-E-thalassemia. Thalassemia screening of the mother's blood revealed a Hb level of 6.8g/dl with low MCV and MCH. Her blood film was indicative of thalassemia. Cellulose acetate electrophoresis showed Hb H and Hb Q with the absence of Hb A. Globin chain biosynthesis was carried out and alpha Q- and beta-chains were detected. Normal alpha- chains were absent. Digestion of the mother's DNA with Bam HI and Bgl II followed by hybridization with the 1.5 kb alpha-Pst probe showed a two alpha-gene deletion on one chromosome and the -alpha Q chain mutant with the -alpha 4.2 defect on the other chromosome. DNA amplification studies indicated the two-gene deletion to be of the -SEA/ defect. The patient was concluded to possess Hb Q-H disease (--SEA/-alpha 4.2Q). Cellulose acetate electrophoresis of the father's blood showed the presence of Hb A, F and E. Molecular analysis of the father's DNA confirmed an intact set of alpha-genes (alpha alpha/alpha alpha). Globin chain biosynthesis of fetal blood of their child showed gamma, beta A, beta E, alpha A and alpha Q-chains. Molecular analysis of the child's DNA showed one alpha-gene deletion, thus giving a genotype of alpha alpha/-alpha 4.2Q beta beta E.

  16. Avaliação de Hb A2 e Hb F em doadores de sangue de região malarígena da Amazônia Oriental brasileira por HPLC Evaluation of Hb A2 and Hb F by HPLC in blood donors from the malaria endemic region of Eastern Amazon of Brazil

    Directory of Open Access Journals (Sweden)

    Wanessa C. Souza

    2003-01-01

    Full Text Available In malaria endemic regions of Africa, resistance to infection by Plasmodium has been observed in under 6-month-old children, when there are higher fetal hemoglobin (Hb F levels. Research performed in the São José do Rio Preto region, central-east Brazil, reported increased levels of Hb F in blood donors. The purpose of this work was to evaluate the A2 hemoglobin (Hb A2 and Hb F concentrations in blood donors deriving from the Brazilian malaria endemic region. Forty-five blood donor samples from Macapá, from patients with varying genders, ages and ethnic origins, were collected by venous puncture after informed consent was obtained. The samples were analyzed by High Performance Liquid Chromatography (HPLC - System Variant (Bio-Rad. The HPLC demonstrated sensitivity and rapidity in the identification and measurement of the hemoglobins and gave precise results. Moreover, it provided measurement of hemoglobin variants, even when they were present in small amounts, providing a diagnosis of hemoglobinopathies. Hb F levels above the normal were observed in 33.3% of the analyzed samples. The presence of increased Hb F can suggest resistance to infection by Plasmodium falciparum, as there have been reports that infected red blood cells interfere in the development of the parasite.

  17. Biosafety and biosecurity measures: management of biosafety level 3 facilities.

    Science.gov (United States)

    Zaki, Adel N

    2010-11-01

    With the increasing biological threat from emerging infectious diseases and bioterrorism, it has become essential for governments around the globe to increase awareness and preparedness for identifying and containing those agents. This article introduces the basic concepts of laboratory management, laboratory biosafety and laboratory biosecurity. Assessment criteria for laboratories' biorisk should include both biosafety and biosecurity measures. The assessment requires setting specific goals and selecting management approaches. In order to implement technologies at the laboratory working level, a management team should be created whose role is to implement biorisk policies, rules and regulations appropriate for that facility. Rules and regulations required by government authorities are presented, with special emphasis on methods for air control, and liquid and solid waste management. Management and biorisk measures and appropriate physical facilities must keep pace, ensuring efficient facilities that protect workers, the environment, the product (research, diagnostic and/or vaccine) and the biological pathogen. Published by Elsevier B.V.

  18. Erroneous HbA1c results in a patient with elevated HbC and HbF.

    Science.gov (United States)

    Adekanmbi, Joy; Higgins, Trefor; Rodriguez-Capote, Karina; Thomas, Dylan; Winterstein, Jeffrey; Dixon, Tara; Gifford, Jessica L; Krause, Richard; Venner, Allison A; Clarke, Gwen; Estey, Mathew P

    2016-11-01

    HbA1c is used in the diagnosis and monitoring of diabetes mellitus (DM). Interference from hemoglobin variants is a well-described phenomenon, particularly with HPLC-based methods. While immunoassays may generate more reliable HbA1c results in the presence of some variants, these methods are susceptible to negative interference from high concentrations of HbF. We report a case where an accurate HbA1c result could not be obtained by any available method due to the presence of a compound hemoglobinopathy. HbA1c was measured by HPLC, immunoassay, and capillary electrophoresis. Hemoglobinopathy investigation consisted of a CBC, hemoglobin fractionation by HPLC and electrophoresis, and molecular analysis. HbA1c analysis by HPLC and capillary electrophoresis gave no result. Analysis by immunoassay yielded HbA1c results of 5.9% (Siemens DCA 2000+) and 5.1% (Roche Integra), which were inconsistent with other markers of glycemic control. Hemoglobinopathy investigation showed HbC with the hereditary persistence of fetal hemoglobin-2 Ghana deletion. Reliable HbA1c results may be unobtainable in the presence of some hemoglobinopathies. HPLC and capillary electrophoresis alerted the laboratory to the presence of an unusual hemoglobinopathy. Immunoassays generated falsely low results without warning, which could lead to missed diagnoses and under treatment of patients with DM. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Effect of iron deficiency anemia and iron supplementation on HbA1c levels - Implications for diagnosis of prediabetes and diabetes mellitus in Asian Indians.

    Science.gov (United States)

    Madhu, S V; Raj, Abhishek; Gupta, Stuti; Giri, S; Rusia, Usha

    2017-05-01

    We investigated the effect of iron deficiency anemia (IDA) on levels of glycated hemoglobin (HbA1c) and to compare its levels before and after iron supplementations. Age and sex matched subjects were enrolled and clustered in 2 groups: IDA (n=62) and healthy controls (HC; n=60). HbA1c levels were estimated by HPLC. Hemogram were estimated by hematology analyser. Serum ferritin (ELISA) and other parameters of iron profile were measured by standard guidelines of ICSH. HbA1c values and iron studies were repeated after 3months of iron supplementation to determine the effect of iron therapy on HbA1c levels. Significantly higher HbA1c levels were observed in IDA subjects compared to HC (5.51±0.696 v/s 4.85±0.461%, pHbA1c and hemoglobin, hematocrit, RBC count, MCH, MCHC and serum ferritin in IDA subjects (r=-0.632, -0.652, -0.384, -0.236, -0.192 and -0.441). Significant decline was noticed in HbA1c levels in IDA subjects after iron supplementation (5.51±0.696 before treatment v/s 5.044±0.603 post-treatment; pHbA1c in pre-diabetes range normalised to normal glucose tolerance (NGT) range and out of 6 patients with pre-treatment HbA1c in diabetes range, 5 reverted to pre-diabetes range while 1 of them reverted to the NGT range. Caution must be exercised in interpreting the results of HbA1c in patients of IDA and iron deficiency must be corrected before diagnosing diabetes and pre-diabetes solely on the basis of HbA1c criteria. Copyright © 2016. Published by Elsevier B.V.

  20. Glycated haemoglobin (HbA1c ) and fasting plasma glucose relationships in sea-level and high-altitude settings.

    Science.gov (United States)

    Bazo-Alvarez, J C; Quispe, R; Pillay, T D; Bernabé-Ortiz, A; Smeeth, L; Checkley, W; Gilman, R H; Málaga, G; Miranda, J J

    2017-06-01

    Higher haemoglobin levels and differences in glucose metabolism have been reported among high-altitude residents, which may influence the diagnostic performance of HbA 1c . This study explores the relationship between HbA 1c and fasting plasma glucose (FPG) in populations living at sea level and at an altitude of > 3000 m. Data from 3613 Peruvian adults without a known diagnosis of diabetes from sea-level and high-altitude settings were evaluated. Linear, quadratic and cubic regression models were performed adjusting for potential confounders. Receiver operating characteristic (ROC) curves were constructed and concordance between HbA 1c and FPG was assessed using a Kappa index. At sea level and high altitude, means were 13.5 and 16.7 g/dl (P > 0.05) for haemoglobin level; 41 and 40 mmol/mol (5.9% and 5.8%; P < 0.01) for HbA 1c ; and 5.8 and 5.1 mmol/l (105 and 91.3 mg/dl; P < 0.001) for FPG, respectively. The adjusted relationship between HbA 1c and FPG was quadratic at sea level and linear at high altitude. Adjusted models showed that, to predict an HbA 1c value of 48 mmol/mol (6.5%), the corresponding mean FPG values at sea level and high altitude were 6.6 and 14.8 mmol/l (120 and 266 mg/dl), respectively. An HbA 1c cut-off of 48 mmol/mol (6.5%) had a sensitivity for high FPG of 87.3% (95% confidence interval (95% CI) 76.5 to 94.4) at sea level and 40.9% (95% CI 20.7 to 63.6) at high altitude. The relationship between HbA 1c and FPG is less clear at high altitude than at sea level. Caution is warranted when using HbA 1c to diagnose diabetes mellitus in this setting. © 2017 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  1. Efficacy of acarbose and metformin in newly diagnosed type 2 diabetes patients stratified by HbA1c levels.

    Science.gov (United States)

    Zhang, Jin-Ping; Wang, Na; Xing, Xiao-Yan; Yang, Zhao-Jun; Wang, Xin; Yang, Wen-Ying

    2016-07-01

    The aim of the present study was to investigate whether the therapeutic efficacy of acarbose and metformin is correlated with baseline HbA1c levels in Chinese patients with newly diagnosed type 2 diabetes mellitus (T2DM). Data for 711 subjects were retrieved from the MARCH (Metformin and AcaRbose in Chinese as initial Hypoglycemic treatment) trial database and reviewed retrospectively. Patients were grouped according to baseline HbA1c levels (8%) and the results for these three groups were compared between acarbose and metformin treatments. Acarbose and metformin treatment significantly improved T2DM-associated parameters (weight, fasting plasma glucose [FPG], postprandial glucose [PPG], glucagon-like peptide-1 [GLP-1], HOMA-IR, and total cholesterol) across all HbA1c levels. Acarbose decreased PPG and HOMA-β significantly more than metformin, but only in subjects with lower baseline HbA1c (PPG in the HbA1c levels (P HbA1c groups (all P HbA1c levels, whereas metformin induced greater reductions in FPG. These results may help guide selection of initial therapy based on baseline HbA1c. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  2. Relationship between Hb and HbA1c in Japanese adults: an analysis of the 2009 Japan Society of Ningen Dock database.

    Science.gov (United States)

    Takahashi, Eiko; Moriyama, Kengo; Yamakado, Minoru

    2014-06-01

    We investigated the effect of Hb on HbA1c levels in 265,427 Japanese individuals. The divergence between fasting plasma glucose (FPG) and HbA1c levels increased with lower Hb, resulting in HbA1c levels that were higher in relation to than the FPG levels. Similarly, the correlation between FPG and HbA1c levels, stratified by Hb, weakened as Hb decreased. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Benchmarking by HbA1c in a national diabetes quality register--does measurement bias matter?

    Science.gov (United States)

    Carlsen, Siri; Thue, Geir; Cooper, John Graham; Røraas, Thomas; Gøransson, Lasse Gunnar; Løvaas, Karianne; Sandberg, Sverre

    2015-08-01

    Bias in HbA1c measurement could give a wrong impression of the standard of care when benchmarking diabetes care. The aim of this study was to evaluate how measurement bias in HbA1c results may influence the benchmarking process performed by a national diabetes register. Using data from 2012 from the Norwegian Diabetes Register for Adults, we included HbA1c results from 3584 patients with type 1 diabetes attending 13 hospital clinics, and 1366 patients with type 2 diabetes attending 18 GP offices. Correction factors for HbA1c were obtained by comparing the results of the hospital laboratories'/GP offices' external quality assurance scheme with the target value from a reference method. Compared with the uncorrected yearly median HbA1c values for hospital clinics and GP offices, EQA corrected HbA1c values were within ±0.2% (2 mmol/mol) for all but one hospital clinic whose value was reduced by 0.4% (4 mmol/mol). Three hospital clinics reduced the proportion of patients with poor glycemic control, one by 9% and two by 4%. For most participants in our study, correcting for measurement bias had little effect on the yearly median HbA1c value or the percentage of patients achieving glycemic goals. However, at three hospital clinics correcting for measurement bias had an important effect on HbA1c benchmarking results especially with regard to percentages of patients achieving glycemic targets. The analytical quality of HbA1c should be taken into account when comparing benchmarking results.

  4. [Detecting HB-1 Expression Level in Bone Marrow of Acute Leukemia Patients by Real-Time Fluorescence Quantitative RT-PCR].

    Science.gov (United States)

    Wang, Qing-Yun; Li, Yuan; Ji, Li; Liang, Ze-Yin; Liu, Wei; Ren, Han-Yun; Qiu, Zhi-Xiang

    2018-02-01

    To investigate the expression level of HB-1 gene in patients with acute lymphoblastic leukemia (ALL) and the significance of HB-1 gene in monitoring of minimal residual disease (MRD). The method of real-time fluorescence quantitative RT-PCR (Taqman probe) was established to detect the expression levels of HB-1 gene; then the sensitivity, specificity and repeatability of this assay were evaluated and verified. The HB-1 gene expression levels in bone marrow of 183 cases of ALL, 70 cases of acute myeloid leukemias (AML), 52 cases of non-malignant hematologic diseases and 24 healthy hematopoietic stem cell donors were detected. The correlation of HB-1 level with diagnosis and relapse was analyzed by detecting bone marrow samples of 33 B-ALL. The sensitivity of this assay reached the 10 -4 level. The coefficient of variation for inter-batch and inter-tube of HB-1 were 6.79% and 4.80%, respectively. It was found that HB-1 gene specifically expressed in acute B lymphoblastic leukemia. The median expression levels of HB-1 gene in newly diagnosed and relapsed B-ALL patients were statistically significantly higher than those in ALL in complete remission(CR), newly diagnosed T-ALL, newly diagnosed AML, non-malignant hematologic diseases, and healthy hematopoietic stem cell donors(33.0% vs 0.68%, 0.07%, 0.02%, 0.58% and 0, respectively) (P0.05). The expression level of HB-1 gene declined sharply when B-ALL patients reached complete remission (0-7.99%, with median level 0.68%), but increased when relapsed (7.69%, 8.08% and 484.0% in 3 relapsed samples), which was in accordance with results of flow cytometry. HB-1 gene specifically expressed in acute B lymphoblastic leukemia cells. The established real-time fluorescence quantitative RT-PCR assay shows good sensitivity, specificity and repeatability, thus, can be used as a biological marker in the clinical detection, monitoring MRD and predicting of early relapse for B-ALL patients.

  5. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes

    DEFF Research Database (Denmark)

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L

    2017-01-01

    AIMS/HYPOTHESIS: This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA1c measureme...

  6. HbA1c and Glycated Albumin Levels Are High in Gastrectomized Subjects with Iron-Deficiency Anemia.

    Science.gov (United States)

    Inada, Shinya; Koga, Masafumi

    2017-01-01

    We report that glycated albumin (GA) is higher relative to HbA1c in non-diabetic, gastrectomized subjects without anemia, and thus is a sign of oxyhyperglycemia. It is known that gastrectomized subjects are prone to iron-deficiency anemia (IDA), and that the HbA1c levels of subjects with IDA are falsely high. In the present study, the HbA1c and GA levels of gastrectomized subjects with IDA were compared with gastrectomized subjects without anemia. Seven non-diabetic gastrectomized subjects with IDA were enrolled in the present study. Twenty-eight non-diabetic gastrectomized subjects without anemia matched with the subjects with IDA in terms of age, gender, and body mass index were used as the controls. Although there were no significant differences in fasting plasma glucose and OGTT 2-hour plasma glucose (2-h PG) between the two groups, the HbA1c and GA levels in gastrectomized subjects with IDA were significantly higher than the controls. For all of the gastrectomized subjects (n=35), ferritin exhibited a significant negative correlation with HbA1c and GA, and a significant positive correlation with 2-h PG. In addition, the HbA1c and GA levels exhibited a significant negative correlation with the mean corpuscular hemoglobin and hemoglobin. The HbA1c and GA levels in gastrectomized subjects with IDA were significantly higher than those in controls. The high GA levels are attributed to a tendency in which patients with total gastrectomy, who are prone to IDA, are susceptible to postprandial hyperglycemia and reactive hypoglycemia, which in turn leads to large fluctuations in plasma glucose. © 2017 by the Association of Clinical Scientists, Inc.

  7. Nitrosylated hemoglobin levels in human venous erythrocytes correlate with vascular endothelial function measured by digital reactive hyperemia.

    Directory of Open Access Journals (Sweden)

    Irina I Lobysheva

    Full Text Available Impaired nitric oxide (NO-dependent endothelial function is associated with the development of cardiovascular diseases. We hypothesized that erythrocyte levels of nitrosylated hemoglobin (HbNO-heme may reflect vascular endothelial function in vivo. We developed a modified subtraction method using Electron Paramagnetic Resonance (EPR spectroscopy to identify the 5-coordinate α-HbNO (HbNO concentration in human erythrocytes and examined its correlation with endothelial function assessed by peripheral arterial tonometry (PAT. Changes in digital pulse amplitude were measured by PAT during reactive hyperemia following brachial arterial occlusion in a group of healthy volunteers (50 subjects. Erythrocyte HbNO levels were measured at baseline and at the peak of hyperemia. We digitally subtracted an individual model EPR signal of erythrocyte free radicals from the whole EPR spectrum to unmask and quantitate the HbNO EPR signals.Mean erythrocyte HbNO concentration at baseline was 219+/-12 nmol/L (n = 50. HbNO levels and reactive hyperemia (RH indexes were higher in female (free of contraceptive pills than male subjects. We observed a dynamic increase of HbNO levels in erythrocytes isolated at 1-2 min of post-occlusion hyperemia (120+/-8% of basal levels; post-occlusion HbNO levels were correlated with basal levels. Both basal and post-occlusion HbNO levels were significantly correlated with reactive hyperemia (RH indexes (r = 0.58; P<0.0001 for basal HbNO.The study demonstrates quantitative measurements of 5-coordinate α-HbNO in human venous erythrocytes, its dynamic physiologic regulation and correlation with endothelial function measured by tonometry during hyperemia. This opens the way to further understanding of in vivo determinants of NO bioavailability in human circulation.

  8. Correlation of MMP-9, GA, HbA1c, and adipokines levels with DR

    Directory of Open Access Journals (Sweden)

    Cheng Qian

    2017-12-01

    Full Text Available AIM: To investigate the correlation of matrix metalloproteinase -9(MMP-9, glycated albumin(GA, glycosylated hemoglobin(HbA1cand adipokines(including visfatin, resistin and leptinwith diabetic retinopathy(DR. METHODS: From March 2015 to March 2017, 74 patients with DR were treated in our hospital, including 40 patients(80 eyeswith non proliferative diabetic retinopathy(NPDRand 34 patients(68 eyeswith proliferative diabetic retinopathy(PDR, and diabetes mellitus 40 patients(80 eyeswith non DR(NDRand 40 healthy volunteers(80 eyeswere selected as controls, the levels of MMP-9, GA, HbA1c, visfatin, resistin and leptin in each group were detected. RESULTS: PDR group visfatin was 4.41±0.82ng/mL, was significantly lower than the NPDR group, NDR group and control group(PPPPrs=0.523, 0.461 and 0.414, Prs=-0.433, Prs=0.401 and 0.460, PCONCLUSION: MMP-9, GA, HbA1c, and adipokines may play a role in the development and progression of DR, in which MMP-9 is associated with adipokines, both are not significantly related to the levels of GA and HbA1c.

  9. Hb Melusine and Hb Athens-Georgia: potentially underreported in the Belgian population? Four cases demonstrating the lack of detection using common CE-HPLC methods either for glycated hemoglobin (HbA1C) analysis or Hb variant screening.

    Science.gov (United States)

    Peeters, Bart; Brandt, Inger; Desmet, Koenraad; Harteveld, Cornelis L; Kieffer, Davy

    2016-12-01

    Suspected hemoglobin (Hb) variants, detected during HbA 1C measurements should be further investigated, determining the extent of the interference with each method. This is the first report of Hb Melusine and Hb Athens-Georgia in Caucasian Belgian patients. Intervention & Technique: Since common CE-HPLC methods for HbA 1C analysis or Hb variant screening are apparently unable to detect these Hb variants, their presence might be underestimated. HbA 1C analysis using CZE, however, alerted for their presence. Moreover, in case of Hb Melusine, even Hb variant screening using CZE was unsuccessful in its detection. Fortunately, carriage of Hb Melusine or Hb Athens-Georgia variants has no clinical implications and, as shown in this report, no apparent difference in HbA 1C should be expected.

  10. Change in HbA1c Levels between the Age of 8 Years and the Age of 12 Years in Dutch Children without Diabetes: The PIAMA Birth Cohort Study

    Science.gov (United States)

    Jansen, Hanneke; Wijga, Alet H.; Scholtens, Salome; Koppelman, Gerard H.; Postma, Dirkje S.; Brunekreef, Bert; de Jongste, Johan C.; Smit, Henriëtte A.; Stolk, Ronald P.

    2015-01-01

    Objective HbA1c is associated with cardiovascular risk in persons without diabetes and cardiovascular risk accumulates over the life course. Therefore, insight in factors determining HbA1c from childhood onwards is important. We investigated (lifestyle) determinants of HbA1c at age 12 years and the effects of growth on change in HbA1c and the tracking of HbA1c between the age of 8 and 12 years. Study Design and Methods Anthropometric measurements were taken and HbA1c levels were assessed in 955 children without diabetes aged around 12 years participating in the PIAMA birth cohort study. In 363 of these children HbA1c was also measured at age 8 years. Data on parents and children were collected prospectively by questionnaires. Results We found no significant association between known risk factors for diabetes and HbA1c at age 12 years. Mean(SD) change in HbA1c between ages 8 and 12 years was 0.6(0.7) mmol/mol per year (or 0.1(0.1) %/yr). Anthropometric measures at age 8 and their change between age 8 and 12 years were not associated with the change in HbA1c. 68.9% of the children remained in the same quintile or had an HbA1c one quintile higher or lower at age 8 years compared to age 12 years. Conclusion The lack of association between known risk factors for diabetes and HbA1c suggest that HbA1c in children without diabetes is relatively unaffected by factors associated with glycaemia. HbA1c at age 8 years is by far the most important predictor of HbA1c at age 12. Therefore, the ranking of HbA1c levels appear to be fairly stable over time. PMID:25875773

  11. HbA1c Levels among Primary Healthcare Patients with Type 2 Diabetes Mellitus in Oman

    Directory of Open Access Journals (Sweden)

    Jawad A Al-Lawati

    2012-11-01

    Full Text Available Objectives: To investigate whether younger patients with type 2 diabetes mellitus have higher glycated hemoglobin A1c (HbA1c levels compared to older patients, and to determine the factors associated with higher HbA1c levels.Methods: Data from 1,266 patients from all over Oman were used to obtain the mean HbA1c level, odds ratios (OR, and 95% confidence intervals (CI from multiple logistic regression models with age groups, sex, duration of diabetes, diabetes treatment, body mass index, estimated glomerular filtration rate (eGFR, tobacco use, and healthcare index as predictors of good (HbA1c <7% vs.poor (≥7% glycemic control.Results: Mean HbA1c levels were 8.9, 8.3, and 7.8 in the age groups 20-39, 40-59 and 60+ years, respectively. After controlling for all other covariates, the OR of good glycemic control increased with age, 40-59 years old (OR=1.7; 95% CI 1.1 to 2.6 and 60+ year (OR=2.5; 95% CI 1.6 to 4.0, female gender (OR=1.5; 95% CI 1.2 to 2.0 and in patients with eGFR ≥60 mL/min/1.73 m2 (OR=1.9; 95% CI 1.1 to 3.3. Longer duration of diabetes (≥5years and treatment with oral agents or insulin were inversely related to good glycemic control.Conclusion: Younger Omani adults exhibit worse glycemic levels compared to older adults posing a formidable challenge to diabetes care teams.

  12. Iron deficiency anemia interfering the diagnosis of compound heterozygosity for Hb constant spring and Hb Paksé: The first case report.

    Science.gov (United States)

    Chiasakul, Thita; Uaprasert, Noppacharn

    2018-01-01

    Diagnosis of thalassemia or hemoglobinopathy concomitant with iron deficiency anemia (IDA) is challenging. We report a case of 43-year-old female whose diagnosis of compound heterozygosity for hemoglobin Constant Spring (HbCS) and Hb Paksé became apparent after the treatment of IDA. Prior to treatment, Hb analysis using isoelectric focusing (IEF) showed HbA 95.6%, HbA 2 2.7%, and HbCS 1.7% compatible with heterozygous HbCS. After 4 months of oral iron therapy resulting in an improved Hb level, her HbCS level was substantially increased to 8.7% on IEF suggesting homozygous HbCS. Subsequent DNA analysis using multiplex amplification refractory mutation system analysis revealed compound heterozygosity for HbCS and Hb Paksé. This case demonstrated that IDA can significantly reduce HbCS/Hb Paksé levels and probably mask the diagnosis of homozygous HbCS, homozygous Hb Paksé or the compound heterozygosity for both hemoglobinopathies by hemoblogin analysis. The test should be repeated after resolution of IDA, or molecular testing should be performed to confirm the diagnosis. © 2017 Wiley Periodicals, Inc.

  13. Relationship between Plasma Ferritin Level and Siderocyte Number in Splenectomized β-Thalassemia/HbE Patients

    Directory of Open Access Journals (Sweden)

    A. Tripatara

    2012-01-01

    Full Text Available Introduction. In iron overload status, excess iron deposits in reticuloendothelial cells and tissues and can be detected using Prussian blue staining. The aim of this paper was to investigate the relationship between siderocyte numbers and plasma ferritin levels (a practically standard marker of iron overload in the blood of the splenectomized and nonsplenectomized β-thalassemia/HbE patients, who are at risk of iron overload. Methods. EDTA blood samples from 64 patients with 35 splenectomized and 29 nonsplenectomized β-thalassemia/HbE patients, who received regular blood transfusions, and 20 normal individuals were investigated for siderocyte numbers, plasma ferritin levels, and complete blood counts. Results. The average percent siderocytes in splenectomized and nonsplenectomized β-thalassemia/HbE patients were 11.5% and 0.08%, respectively, and plasma ferritin levels of 2,332 μg/L and 1,279 μg/L, respectively. Percent siderocytes showed a good correlation with plasma ferritin levels only in splenectomized patients (r=0.69, P<0.001. A receiver operating curve analysis from splenectomized patients’ data indicated that siderocytes at 3% cut-off are the best predictor for plasma ferritin level ≥1,000 μg/L with 92.9% sensitivity and 42.9% specificity. Conclusion. Circulating siderocyte numbers can be used as a screening test for the assessment of the iron overload in splenectomized β-thalassemia/HbE patients in the place where serum ferritin is not available.

  14. Detection of Co-inheritance of Hb Hope and Hb Constant Spring in Three Thai Samples by Capillary Electrophoresis.

    Science.gov (United States)

    Panyasai, Sitthichai; Pornprasert, Sakorn

    2016-06-01

    The diagnosis of co-inheritance of Hb Hope [β136(H14)Gly → Asp, GGT > GAT] and Hb constant spring [Hb CS; α142, Term → Gln (TAA > CAA IN α2)] by high performance liquid chromatography (HPLC) is difficult because Hb Hope has a HPLC elution pattern similar to that of Hb Pyrgos, Hb New York, Hb Kodaira, and Hb Phimai. Moreover, the Hb CS mRNA, as well as the gene product, are unstable and present at a low level in peripheral blood. We report the use of a capillary electrophoresis (CE) for diagnosis of co-inheritance of Hb Hope and Hb CS in 3 Thai females who had mild anemia with Hb and Hct varying from 91-114 g/L to 0.28-0.36 L/L, respectively. Hb Hope eluted with a retention time of 125-140 s (Zone 10) of CE electrophoregram. Furthermore, the peak of Hb CS at the retention time of 245-250 s (Zone 2) was observed in these samples. In addition, the manual analysis by taking the non-black area under both peaks of HbA and Hb Hope (inverted V) into account provided the corrected Hb CS levels which are useful in screening of heterozygote or homozygote for Hb CS. Thus, the CE method provides an accurate diagnosis of Hb Hope and Hb CS which is useful in genetic counseling, prevention and control programs for these hemoglobinopathies.

  15. (HbA1c) levels with Iinsulin resistance in obese children.

    African Journals Online (AJOL)

    Objectives: We investigated the relationship between insulin resistance reflected by homeostasis model assessment (HOMA-IR) index and serum HbA1c levels of obese children. Material and Methods: This study included 70 obese and 60 normal weight healthy children between the ages of 3 and 15. Anthropometric ...

  16. Predictors of HbA1c levels in patients initiating metformin

    NARCIS (Netherlands)

    Martono, Doti P; Hak, Eelko; Lambers Heerspink, Hiddo; Wilffert, Bob; Denig, Petra

    2016-01-01

    Objective: The aim was to assess demographic and clinical factors as predictors of short (6 months) and long term (18 months) HbA1c levels in diabetes patients initiating metformin treatment. Research design and methods: We conducted a cohort study including type 2 diabetes patients who received

  17. Prevalence of high HbA1c levels in Brazilian adolescents: The Study of Cardiovascular Risk in Adolescents.

    Science.gov (United States)

    de Cássia Lima Fernandes, Rita; Teló, Gabriela H; Cureau, Felipe V; Barufaldi, Laura A; Kuschnir, Maria Cristina C; Schaan, Beatriz D; Szklo, Moyses; Bloch, Katia V

    2017-03-01

    To evaluate the prevalence of elevated glycated haemoglobin (HbA1c) levels in a population of adolescents participating in the Study of Cardiovascular Risk in Adolescents. This is a school-based cross-sectional study based on a complex sample of adolescents 12-17years old representative at the national and macro-regional levels and for each Brazilian state capital. Blood was collected in schools and then evaluated in a single laboratory. HbA1c levels were considered elevated if ⩾5.7% (39mmol/mol) and were analyzed according to sex, age, macro-region, type of school, skin color, and nutritional status. Data from 37,804 adolescents were analyzed. The mean level of HbA1c was 5.4% (95%CI 5.4-5.4) (36mmol/mol [95%CI 36-36]), and 20.5% (95%CI 19.1-22.0) of adolescents presented values ⩾5.7% (⩾39mmol/mol). Among males, 23.6% (95%CI 21.8-25.6) showed elevated HbA1c levels compared to 17.5% (95%CI 15.9-19.2) observed in females. The prevalence of elevated levels of HbA1c was higher in adolescents with black skin color (27.6%; 95%CI 23.2-32.4) vs. white skin color (16.9%; 95%CI 15.4-18.5), and higher in those who studied in public schools (21.6%; 95%CI 20.0-23.4) vs. private schools (16.7%; 95%CI 14.7-19.0). Among obese adolescents, 29.7% (95%CI 25.4-34.3) had elevated levels of HbA1c, compared to 19.3% (95%CI 18.0-20.7) in normal weight students and 19.7% (95%CI 17.1-22.6) in overweight adolescents. Obese male adolescents of lower socioeconomic status had a higher prevalence of elevated HbA1c levels. Our findings highlight the importance of focusing on this high risk group for interventions to prevent diabetes. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Novel Variant with Positive Natural Selection Influenced Hb A2 Levels in Chinese Individuals with β-Thalassemia.

    Science.gov (United States)

    Yu, Shanjuan; Chen, Yang; Lai, Ketong; Dewan, Roma Kajal; He, Yunyan

    2017-05-01

    β-Thalassemia (β-thal) is the most common inherited hemolytic anemia worldwide. Elevated Hb A 2 is a mark of β-thal carriers. The aim of this study was to identify the pathogenic variants associated with the Hb A 2 levels. One thousand and thirty β-thal carriers were recruited for this study. Using positive natural expression quantitative trait loci (eQTL) analysis, a significant variant was selected. Genotyping for the rs231841 polymorphism was performed by the Sequenom MassARRAY IPLEX platform. All genetic association analyses were performed with the PLINK program. The linear regression analysis showed that rs231841 in the intron region of the potassium voltage-gated channel subfamily Q member 1 (KCNQ1) gene on chromosome 11p15 was significantly associated with Hb A 2 levels. The presence of the C allele was associated with elevated Hb A 2 levels. Our results suggest that rs231841 on the KCNQ1 gene with positive natural selection is related to Hb A 2 levels in Chinese β-thal carriers, and KCNQ1 is probably associated with the expression of the β-like globin gene cluster.

  19. Study on the effects of Jinqi hypoglycemic table on serum P-sel, TNF-α and HbAlc levels in patients with type two diabetes mellitus

    International Nuclear Information System (INIS)

    Qi Falian; Xu Jun; Wang Bin; Chen Yingjian; Yin Qiuxia; Ke Bingshen

    2007-01-01

    Objective: To study the effects of Huang Qi and Huang Lian on serum P-selectin, tumor necrosis factor-α (TNF-α), glucose and glycosylated hemoglobin (HbAlc) levels in patients with type two diabetes mellitus (DM). Methods: Sixty DM2 patients were divided randomly into 2 equal numbered groups: one group were treated with routine hypoglycemic medicine, in other group, Jinqi hypoglycemic tablets were added besides western medicine. Fasting blood glucose, two hour postprandial glucose, HbAlc, P-SLT and TNF-α levels were measured detected before and after three months' treatment. Results: There were no significant differences between the plasma glucose, HbAlc, P-SLT and TNF-α levels (P>0.05) in the JinQi group and western medicine group before treatment. Fasting plasma glucose and postprandial glucose were decreased after treatment in both groups. HbAlc, P-SLT and TNF-α levels were significantly decreased after treatment (P<0.05, P<0.01, P<0.01) in JinQi group. Conclusion: On the basis of treatment with western medicine, additional Huang Lian and Huang Qi could further decrease HbAlc, P-SLT and TNF-α levels, stabilize blood glucose and provide better therapeutic results in patients with type 2 diabetes mellitus. (authors)

  20. Measuring the quality of child health care at first-level facilities.

    Science.gov (United States)

    Gouws, Eleanor; Bryce, Jennifer; Pariyo, George; Armstrong Schellenberg, Joanna; Amaral, João; Habicht, Jean-Pierre

    2005-08-01

    Sound policy and program decisions require timely information based on valid and relevant measures. Recent findings suggest that despite the availability of effective and affordable guidelines for the management of sick children in first-level health facilities in developing countries, the quality and coverage of these services remains low. We report on the development and evaluation of a set of summary indices reflecting the quality of care received by sick children in first-level facilities. The indices were first developed through a consultative process to achieve face validity by involving technical experts and policymakers. The definition of evaluation measures for many public health programs stops at this point. We added a second phase in which standard statistical techniques were used to evaluate the content and construct validity of the indices and their reliability, drawing on data sets from the multi-country evaluation of integrated management of childhood illness (MCE) in Brazil, Tanzania and Uganda. The statistical evaluation identified important conceptual errors in the indices arising from the theory-driven expert review. The experts had combined items into inappropriate indicators resulting in summary indices that were difficult to interpret and had limited validity for program decision making. We propose a revised set of summary indices for the measurement of child health care in developing countries that is supported by both expert and statistical reviews and that led to similar programmatic insights across the three countries. We advocate increased cross-disciplinary research within public health to improve measurement approaches. Child survival policymakers, program planners and implementers can use these tools to improve their monitoring and so increase the health impact of investments in health facility care.

  1. Comparison of Serum Zinc Level in Patients with Diabetes Type 1 and 2 and Its' Relation to HbA1c

    Directory of Open Access Journals (Sweden)

    Fatemeh Dorreh

    2014-01-01

    Full Text Available Background: Diabetes Mellitus (DM is a major health care problem. The relationship between DM and zinc has frequently been reported in various research. The present study aims to investigate serum zinc level in patients with type 1 (IDDM and type 2 (NIDDM. Association between glyaceted hemoglobin and level of zinc is also evaluted. Materials and Methods: This cross-sectional study was conducted on 60 subjects with DM (Type l: N=30; Type 2: N=30 who met inclusion criteria of the study. Patients’ serum zinc level and HbA1c were measured. Data were analyzed using t-test and Mann-Withney U test. Results: Seventy five percent of the subjects were female. The average age of the IDDM was 15.36±5.28 years and that of NIDDM was 48.70±11.45 years. The average HbA1c of subjects was 8.06±1.64%. The average serum level of zinc in IDDM group was 95.82±14.51 μg/dl and that of NIDDM was 97.47±32.36 μg/dl, no significant difference was found between the two groups. Serum zinc difficiency was detected in 20% of the patients with NIDDM and 16.6% of the patients with IDDM. However, no significant correlation between HbA1c and serum level of zinc was detected in this study. Conclusion: Zinc deficiency was detected among a significant percentage of IDDM and NIDDM patients, but no significant correlation between serum zinc level and HbA1c was detected.

  2. HbA1c levels as a function of emotional regulation and emotional intelligence in patients with type 2 diabetes.

    Science.gov (United States)

    Coccaro, Emil F; Drossos, Tina; Phillipson, Louis

    2016-10-01

    Understanding the role of emotion in glycemic control may be critical for the long-term treatment of patients with type 2 diabetes (T2D). In this study we investigated the relationship between measures of emotional regulation and emotional intelligence and HbA1c levels in adult patients with T2 diabetes. 100 adult patients with T2 diabetes completed assessments of emotional regulation (i.e., affect intensity/lability) and emotional intelligence and were then correlated with HbA1c levels with several relevant covariates. HbA1c levels were significantly associated with affect intensity (AI: r=.24, p=.018) and with emotional intelligence (EI: r=-.29, p=.004), but not affect lability. These results were the same even after adding income, state depression scores, insulin-dependent status, serum cholesterol, diabetes literacy and self-care as covariates (AI: β=.33, p=.001; EI: β=-.31, p=.002). Diabetes self-care, but not diabetes literacy, was also associated with HbA1c levels (β=-.29, p=.003). These data suggest that aspects of emotional regulation and emotional intelligence play a role in glycemic control in adult patients with T2 diabetes and do so even in the context of several variables relevant to diabetes. If so, interventions that can reduce affect intensity and/or increase emotional intelligence may represent a new strategy in the glycemic control of adult patients with T2 diabetes. Copyright © 2016 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  3. Genetic Variants at BCL11A and HBS1L-MYB loci Influence Hb F Levels in Chinese Zhuang β-Thalassemia Intermedia Patients.

    Science.gov (United States)

    Lai, Yunli; Chen, Yun; Chen, Biyan; Zheng, Haiyang; Yi, Sheng; Li, Guojian; Wei, Hongwei; He, Sheng; Zheng, Chenguang

    2016-11-01

    Increased Hb F levels can ameliorate the symptoms of β-thalassemia (β-thal). Due to the genetic heterogenicity of β-thal, the relationship between genetic variants in modifier genes and Hb F level has been studied in different populations. The Chinese Zhuang has the second largest population in China and has 6.78% prevalence of β-thal. However, the effects of these single nucleotide polymorphism (SNP) variants on the Hb F levels of β-thal intermedia (β-TI) patients in this population have not been reported. To explore the association between modifier loci (β-globin gene cluster, HBS1L-MYB intergenic region and BCL11A) and Hb F levels in Chinese Zhuang β-TI patients, 96 unrelated β-TI patients (50 males and 46 females) with different Hb F levels were recruited and genotyped by mass spectrometry. A total of 13 SNPs were confirmed to be in a significant relationship with Hb F levels in this population. Of these, high-risk genotypes of six Hb F-associated SNPs, rs9376090, rs7776054, rs9399137, rs9389268, rs9402685 in the HBS1L-MYB intergenic region and rs189984760 in the BCL11A locus, showed association with high Hb F levels, especially for SNPs in linkage disequilibrium. One novel Hb F-associated SNP, rs189984760, was identified in our study. Our findings will be of valuable reference for correlation between modifier genes and Hb F in Chinese Zhuang populations and may lead to better understand the modifying mechanisms for β-thal.

  4. The super sickling haemoglobin HbS-Oman: a study of red cell sickling, K+ permeability and associations with disease severity in patients heterozygous for HbA and HbS-Oman (HbA/S-Oman genotype).

    Science.gov (United States)

    Al Balushi, Halima W M; Wali, Yasser; Al Awadi, Maha; Al-Subhi, Taimoora; Rees, David C; Brewin, John N; Hannemann, Anke; Gibson, John S

    2017-10-01

    Studying different sickle cell genotypes may throw light on the pathogenesis of sickle cell disease (SCD). Here, the clinical profile, red cell sickling and K + permeability in 29 SCD patients (15 patients with severe disease and 14 with a milder form) of HbA/S-Oman genotype were analysed. The super sickling nature of this Hb variant was confirmed. The red cell membrane permeability to K + was markedly abnormal with elevated activities of P sickle , Gardos channel and KCl cotransporter (KCC). Results were consistent with Ca 2+ entry and Mg 2+ loss via P sickle stimulating Gardos channel and KCC activities. The abnormal red cell behaviour was similar to that in the commonest genotype of SCD, HbSS, in which the level of mutated Hb is considerably higher. Although activities of all three K + transporters also correlated with the level of HbS-Oman, there was no association between transport phenotype and disease severity. The super sickling behaviour of HbS-Oman may obviate the need for solute loss and red cell dehydration to encourage Hb polymerisation, required in other SCD genotypes. Disease severity was reduced by concurrent α thalassaemia, as observed in other SCD genotypes, and represents an obvious genetic marker for prognostic tests of severity in young SCD patients of the HbA/S-Oman genotype. © 2017 John Wiley & Sons Ltd.

  5. A1c Gear: Laboratory quality HbA1c measurement at the point of care.

    Science.gov (United States)

    Ejilemele, Adetoun; Unabia, Jamie; Ju, Hyunsu; Petersen, John R

    2015-05-20

    HbA1c is an important part of assessing the diabetic control and since the use of point-of-care devices for monitoring HbA1c is increasing, it is important to determine how these devices compare to the central laboratory. One hundred and twenty patient samples were analyzed on the Bio-Rad Variant™II and one POC analyzer (Sakae A1c Gear). Three patient sample pools containing ~5%, ~7%, and ~10% HbA1c levels were run over 20 days. Three reagent lots and three instruments were evaluated for the A1c Gear. The 120 patient samples showed strong correlation (R(2)>0.989) when compared to the Variant™II with means=8.06% and 7.81%, for Variant IIand A1c Gear, respectively. Changing reagent lots or instruments had no impact for the A1c Gear. The ~5%, ~7%, and ~10% pools within-run and between-run imprecision was between 0.87-1.33% and 1.03-1.32%, and 1.41-2.35% and 1.24-1.89% with total imprecision of 1.67-2.35% and 1.61-2.31% for the A1c Gear and Variant II, respectively. The A1c Gear showed a small negative bias (0.25% HbA1c) across HbA1c measurement ranges of Gear meets the criteria of total CV Gear can give results as precise as the laboratory at the POC. Copyright © 2015. Published by Elsevier B.V.

  6. Knowledge and Outcome Measure of HbA1c Testing in Asian Indian Patients with Type 2 Diabetes from a Tertiary Care Center

    Science.gov (United States)

    Kumpatla, Satyavani; Medempudi, Srikanth; Manoharan, Deepa; Viswanathan, Vijay

    2010-01-01

    Aim: HbA1c test is considered to be the reliable measure for evaluating long-term glycemic control in type 2 diabetes. The purpose of this study was to evaluate whether knowledge about HbA1c test is associated with a better glycemic control. Materials and Methods: We conducted a cross-sectional survey of 480 (M:F; 287:193) adults with type 2 diabetes attending a tertiary care center during a period of four months. Baseline demographic and clinical data of all the subjects was obtained. Subject’s knowledge about HbA1c test and their target goal was assessed using a questionnaire. Recent HbA1c results were obtained from medical records. Results: Seventy four per cent of the subjects had awareness about HbA1c test and about 43% of those who knew HbA1c test also knew their target goal. 33% remember their last HbA1c result. The mean A1C of Group A was significantly lower when compared with Group B (8.1 ± 1.7 vs 9.2 ± 1.9, P<0.0001). Group C had lower A1C levels compared to Group D (7.7 ± 1.4 vs 8.5 ± 1.9, p<0.0001). Patients who kept their HbA1c less than 7% were significantly higher in Group C than in Group D. (37.8 vs 12.7%, p<0.00001). Subjects had good glycemic control with increasing levels of awareness about HbA1c. Conclusion: Majority of the diabetic patients who attended the tertiary care center for diabetes care knew HbA1c test and half of them were aware about their target goal. Awareness about HbA1c had a positive impact on maintenance of better glycemic control. PMID:20922109

  7. Comparative haematological parameters of HbAA and HbAS genotype children infected with Plasmodium falciparum malaria in Yemen.

    Science.gov (United States)

    Albiti, Anisa H; Nsiah, Kwabena

    2014-04-01

    Sickle haemoglobin (HbS) is known to offer considerable protection against falciparum malaria. However, the mechanism of protection is not yet completely understood. In this study, we investigate how the presence of the sickle cell trait affects the haematological profile of AS persons with malaria, in comparison with similarly infected persons with HbAA. This study is based on the hypothesis that the sickle cell trait plays a protective role against malaria. Children from an endemic malaria transmission area in Yemen were enrolled in this study. Hematological parameters were estimated using manual methods, the percentage of parasite density on stained thin smear was calculated, haemoglobin genotypes were determined on paper electrophoresis, ferritin was measured using enzyme-linked immunosorbent assay, serum iron and TIBC were assayed using spectrophotometer, transferrin saturation index was calculated by dividing serum iron by TIBC and expressing the result as a percentage. Haematological parameters were compared in HbAA- and HbAS-infected children. Falciparum malaria parasitaemia was confirmed in the blood smears of 62 children, 44 (55.7%) of AA and 18 (37.5%) AS, so there was higher prevalence in HbAA children (P = 0.047). Parasite density was lower in HbAS- than HbAA-infected children (P = 0.003). Anaemia was prominent in malaria-infected children, with high proportions of moderate and severe forms in HbAA (P = 0.001). The mean levels of haemoglobin, packed cell volume, reticulocyte count, platelets count, lymphocytes, eosinophils, and serum iron were significantly lower while total leukocytes, immature granulocytes, monocytes, erythrocyte sedimentation rate, transferrin saturation, and serum ferritin were significantly higher in HbAA-infected children than HbAS-infected children. Infection with Plasmodium falciparum malaria caused more significant haematological alterations of HbAA children than HbAS. This study supports the observation that sickle cell trait

  8. The Effect of Prolonged Glucosamine Usage on HbA1c Levels and New-Onset Diabetes Mellitus in Overweight and Obese Middle-Aged Women.

    Science.gov (United States)

    Gommans, Yvonne M M; Runhaar, Jos; Jacobs, Marloes L; Bierma-Zeinstra, Sita M A

    2017-06-01

    The aim of the present study was to evaluate the effect of a 2.5-year glucosamine sulfate intervention on hemoglobin A1c (HbA1c) levels and the incidence of new-onset diabetes mellitus over 6.5 years in middle-aged women with a body mass index ≥27 kg/m 2 . In total, 407 women were randomized into either oral crystalline glucosamine sulfate or placebo. At baseline, 1 year, 2.5 years, and 6.5 years, a blood sample for the HbA1c level was drawn and questionnaires were taken. After 6.5 years there were missing data for some variables, therefore, multiple imputation was used. With the imputed data, a generalized estimating equation was performed to analyze the effect of glucosamine sulfate usage over 6.5 years. Finally, these analyses were rerun for the 2 subgroups of participants with and without high HbA1c level (≥42 mmol/mol) at baseline. There was no significant effect of a 2.5-year glucosamine sulfate intervention on mean HbA1c level or on obtaining a high HbA1c level or new-onset diabetes mellitus over 6.5 years. The subgroup analyses of participants with and without high HbA1c level at baseline were also not statistically significant. However, participants with a high HbA1c level at baseline had higher odds ratios compared with the participants with a normal HbA1c at baseline. There was no effect of glucosamine sulfate on mean HbA1c level nor on obtaining a high HbA1c level or new-onset diabetes mellitus over 6.5 years, especially in participants with a normal HbA1c level at baseline. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. The relationship between HbA(1c) and fasting plasma glucose in patients with increased plasma liver enzyme measurements

    DEFF Research Database (Denmark)

    Christiansen, R; Rasmussen, L Melholt; Nybo, H

    2012-01-01

    levels of increased liver enzyme concentrations. Methods:  Data from 10 065 patients with simultaneous measurement of HbA(1c) , venous fasting plasma glucose, alanine aminotransferase and γ-glutamyl transferase were extracted from our laboratory database. Correlations were investigated in four patient...

  10. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    OpenAIRE

    Chandrashekar, Vani

    2016-01-01

    Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman's rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to st...

  11. Hb variants in Korea: effect on HbA1c using five routine methods.

    Science.gov (United States)

    Yun, Yeo-Min; Ji, Misuk; Ko, Dae-Hyun; Chun, Sail; Kwon, Gye Cheol; Lee, Kyunghoon; Song, Sang Hoon; Seong, Moon Woo; Park, Sung Sup; Song, Junghan

    2017-07-26

    Quantification of glycated hemoglobin (HbA1c) is a challenge in patients with hemoglobin (Hb) variants. We evaluated the impact of various Hb variants on five routine HbA1c assays by comparing with the IFCC reference measurement procedure (RMP). Whole blood samples showing warning flags or no results on routine HPLC HbA1c assays were confirmed for Hb variants and were submitted to HbA1c quantification using Sebia Capillarys 2 Flex Piercing, Roche Tina-quant HbA1c Gen. 2, Bio-Rad Variant II Turbo 2.0, ADAMS HA-8180, Tosoh G8 standard mode, and IFCC RMP using LC-MS. Among 114 samples, the most common variants were Hb G-Coushatta (n=47), Queens (n=41), Ube-4 (n=11), Chad (n=4), Yamagata (n=4), G-His-Tsou (n=2), G-Taipei (n=1), Fort de France (n=1), Hoshida (n=1), and two novel variants (Hb α-globin, HBA 52 Gly>Cys and Hb β-globin, HBB 146 His>Asn). In terms of control samples, all the result of HbA1c were "acceptable", within the criteria of ±7% compared to IFCC RMP target values. However, percentage of "unacceptable" results of samples with Hb variants were 16% for Capillarys 2, 7% for Tina-quant, 51% for Variant II Turbo 2.0, 95% for G8 standard mode, and 89% for HA-8180. The Capillarys 2 and HA-8180 assay did not provide the results in 5 and 40 samples with Hb variants, respectively. HbA1c results from five routine assays in patients with relatively common Hb variants in Korea showed various degrees of bias compared to those of IFCC RMP. Therefore, laboratories should be aware of the limitation of their methods with respect to interference from Hb variants found commonly in their local population and suggest an alternative HbA1c quantification method.

  12. Phenotypic Diversity of Sickle Cell Disease in Patients with a Double Heterozygosity for Hb S and Hb D-Punjab.

    Science.gov (United States)

    Torres, Lidiane S; Okumura, Jéssika V; Belini-Júnior, Édis; Oliveira, Renan G; Nascimento, Patrícia P; Silva, Danilo G H; Lobo, Clarisse L C; Oliani, Sonia M; Bonini-Domingos, Claudia R

    2016-09-01

    Phenotypic heterogeneity for sickle cell disease is associated to several genetic factors such as genotype for sickle cell disease, β-globin gene cluster haplotypes and Hb F levels. The coinheritance of Hb S (HBB: c.20A > T) and Hb D-Punjab (HBB: c.364G > C) results in a double heterozygosity, which constitutes one of the genotypic causes of sickle cell disease. This study aimed to assess the phenotypic diversity of sickle cell disease presented by carriers of the Hb S/Hb D-Punjab genotype and the Bantu [- + - - - -] haplotype. We evaluated medical records from 12 patients with sickle cell disease whose Hb S/Hb D-Punjab genotype and Bantu haplotype were confirmed by molecular analysis. Hb S and Hb D-Punjab levels were quantified by chromatographic analysis. Mean concentrations of Hb S and Hb D-Punjab were 44.8 ± 2.3% and 43.3 ± 1.8%, respectively. Painful crises were present in eight (66.7%) patients evaluated, representing the most common clinical event. Acute chest syndrome (ACS) was the second most prevalent manifestation, occurring in two individuals (16.7%). Three patients were asymptomatic, while another two exhibited greater diversity of severe clinical manifestations. Medical records here analyzed reported a significant clinical diversity in sickle cell disease ranging from the absence of symptoms to wide phenotypic variety. The sickle cell disease genotype, Bantu haplotype and hemoglobin (Hb) levels did not influence the clinical diversity. Thus, we concluded that the phenotypic variation in sickle cell disease was present within a specific genotype for disease regardless of the β-globin gene cluster haplotypes.

  13. The Long and Winding Road to Optimal HbA1c Measurement

    Science.gov (United States)

    Little, Randie R.; Rohlfing, Curt

    2016-01-01

    The importance of hemoglobin A1c (HbA1c) as an indicator of mean glycemia and risks for complications in patients with diabetes mellitus was established by the results of long-term clinical trials, most notably the Diabetes Control and Complications Trial (DCCT) and United Kingdom Prospective Diabetes Study (UKPDS), published in 1993 and 1998 respectively. However, clinical application of recommended HbA1c targets that were based on these studies was difficult due to lack of comparability of HbA1c results among assay methods and laboratories. Thus, the National Glycohemoglobin Standardization Program (NGSP) was initiated in 1996 with the goal of standardizing HbA1c results to those of the DCCT/UKPDS. HbA1c standardization efforts have been highly successful; however, a number of issues have emerged on the “long and winding road” to better HbA1c, including the development of a higher-order HbA1c reference method by the International Federation of Clinical Chemistry (IFCC), recommendations to use HbA1c to diagnose as well as monitor diabetes, and point-of-care (POC) HbA1c testing. Here, we review the past, present and future of HbA1c standardization and describe the current status of HbA1c testing, including limitations that healthcare providers need to be aware of when interpreting HbA1c results. PMID:23318564

  14. Medication Adherence Mediates the Association between Type D Personality and High HbA1c Level in Chinese Patients with Type 2 Diabetes Mellitus: A Six-Month Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Xuemei Li

    2017-01-01

    Full Text Available Aims. To examine the association between Type D personality and HbA1c level and to explore the mediating role of medication adherence between them in patients with type 2 diabetes mellitus (T2DM. Methods. 330 patients went on to complete a self-report measure of medication adherence and the HbA1c tests. Chi-square test, T test, Ordinary Least Square Regression (OLS, and Recentered Influence Function Regression (RIF were employed. Results. Patients with Type D personality had significantly higher HbA1c value (P0.1. On the other hand, when Type D personality was operationalized as a continuous variable, only SI trait was associated with HbA1c level (P<0.01. When NA, SI, and NA×SI term together were entered into regression, only SI was not related to HbA1c level. Furthermore, medication adherence had a significant mediation effect between Type D personality and HbA1c, accounting for 54.43% of the total effect. Conclusion. Type D personality was associated with HbA1c in direct and indirect ways, and medication adherence acted as a mediator role.

  15. Measurements of the ionising radiation level at a nuclear medicine facility performing PET/CT examinations

    International Nuclear Information System (INIS)

    Tulik, P.; Kowalska, M.; Golnik, N.; Budzynska, A.; Dziuk, M.

    2017-01-01

    This paper presents the results of radiation level measurements at workplaces in a nuclear medicine facility performing PET/ CT examinations. This study meticulously determines the staff radiation exposure in a PET/CT facility by tracking the path of patient movement. The measurements of the instantaneous radiation exposure were performed using an electronic radiometer with a proportional counter that was equipped with the option of recording the results on line. The measurements allowed for visualisation of the staff's instantaneous exposure caused by a patient walking through the department after the administration of "1"8F-FDG. An estimation of low doses associated with each working step and the exposure during a routine day in the department was possible. The measurements were completed by determining the average radiation level using highly sensitive thermoluminescent detectors. (authors)

  16. CLD (chronic liver diseases)-HbA1C as a suitable indicator for estimation of mean plasma glucose in patients with chronic liver diseases.

    Science.gov (United States)

    Koga, Masafumi; Kasayama, Soji; Kanehara, Hideo; Bando, Yukihiro

    2008-08-01

    In patients with chronic liver diseases (CLD), turnover of erythrocytes is increased whereas that of serum albumin is decreased. Thus, glycated hemoglobin (HbA(1C)) and glycated albumin (GA) cannot be used as adequate indicators for chronic plasma glucose control in diabetic patients with CLD. In this investigation, we have proposed CLD-HbA(1C), a novel long-term glycemic control marker by using measured HbA(1C) and GA. We studied 82 patients with CLD in whom glycemic control was regarded as to be stable. Daily plasma glucose profiles were monitored and estimated levels of HbA(1C) were calculated on the conversion formula established by Rohlfing et al. [C.L. Rohlfing, J.D. England, H.M. Wiedmeyer, A. Tennill, R.R. Little, D.E. Goldstein, Defining the relationship between plasma glucose and HbA1c, Diabetes Care 25 (2002) 275-278]. Cholinesterase (ChE) as an indicator for hepatic function was determined at the same time when HbA(1C) and GA levels were measured. CLD-HbA(1C) was defined as the average of measured HbA(1C) and GA/3, based upon the results that among healthy individuals, GA levels were roughly estimated at approximately threefold higher than HbA(1C) levels. While measured HbA(1C) levels in patients with CLD were generally lower than estimated HbA(1C) levels, GA/3 values were generally higher than estimated HbA(1C) levels. Such discrepancies lineally increased in accordance with a decrease in ChE levels. On the other hand, CLD-HbA(1C) levels were highly correlated with estimated HbA(1C) levels (R=0.883), while no significant correlation between CLD-HbA(1C) and ChE was noted. In conclusion, CLD-HbA(1C) has been found a superior chronic glycemic control marker than HbA(1C) or GA in diabetic patients with chronic liver diseases.

  17. [About the HbA1c in the elderly].

    Science.gov (United States)

    Farcet, Anaïs; Delalande, Géraldine; Oliver, Charles; Retornaz, Frédérique

    2016-03-01

    HbA1c product of non enzymatic glycation of HbA increases in relation with the mean blood glucose level during the former 2-3 months. HbA1c levels are correlated with the development of diabetic complications and HbA1c assessment is now the gold standard for evaluation of diabetes control. HbA1c level should not be higher than 7% to avoid these complications. However, in aged peoples, the objectives of diabetes control vary according to their health status. It must be good with HbA1c lower than 7-7.5% in healthy subjects and more relax in subjects with symptoms of frailty and risks of non perceived and self corrected hypoglycemia. Under these conditions, HbA1c values lower than 8 to 9% are advised. Nevertheless, hypoglycemia episodes may occur in patients with high HbA1c and capillary glucose follow-up is necessary for detection of such complications.

  18. K2-EDTA and K3-EDTA Greiner Tubes for HbA1c Measurement.

    Science.gov (United States)

    Vrtaric, Alen; Filipi, Petra; Hemar, Marina; Nikolac, Nora; Simundic, Ana-Maria

    2016-02-01

    To determine whether K2-ethylenediaminetetraacetic acid (EDTA) and K3-EDTA Greiner tubes could be used interchangeably for glycosylated hemoglobin, type A1C (HbA1c) measurement via the Abbott Laboratories ARCHITECT chemiluminescent microparticle HbA1c assay on the ARCHITECT i2000SR immunoanalyzer at our university hospital. We drew blood from a total of 45 outpatients into plastic Greiner Vacuette tubes, some of which were lined with K2-EDTA and others with K3-EDTA anticoagulant. Data are presented as median and interquartile range values. We used the Wilcoxon test and Passing-Bablok regression for tube comparison. For K2-EDTA tubes median HbA1c concentration was 54 mmol/mol (41 to 71 mmol/mol) and for K3-EDTA tubes 56 mmol/mol (43 to 69 mmol/mol). There was no statistically significant difference between K2-EDTA and K3-EDTA (bias= -1.29 mmol/mol; P = 0.24). Passing-Bablok regression showed that there is no constant and proportional error: y = -0.23 (95% CI[-3.52 to 0.69]) + 1.00( 95% CI[0.98 to 1.06]) x. In this study, we provide evidence for the lack of any clinically and statistically significant bias between K2-EDTA and K3-EDTA HbA1c measurements. Thus, Greiner tubes lined with K2-EDTA and those lined with K3-EDTA can safely be used interchangeably to measure HbA1c via the Abbott Laboratories ARCHITECT assay. © American Society for Clinical Pathology, 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Improving access to HbA1c in sub-Saharan Africa (IA3) cohort: cohort profile.

    Science.gov (United States)

    Balde, Naby; Camara, Alioune; Sobngwi-Tambekou, Joelle; Balti, Eric Vounsia; Tchatchoua, Alain; Fezeu, Leopold; Limen, Serge; Ngamani, Sylvie; Ngapout, Suzanne; Kengne, Andre Pascal; Sobngwi, Eugene

    2017-01-01

    Glycated haemoglobin (HbA1c) is the best surrogate of average blood glucose control in diabetic patients, and lowering HbA1c significantly reduces diabetes complications. Moreover, immediate feedback of HbA1c measurement to patients may improve control. However, HbA1c is unavailable in most parts of Africa, a continent with one of the highest burden of diabetes. To translate these evidences, we are conducting a multicentric project in 10 health care facilities in Guinea and Cameroon to evaluate the feasibility and one-year benefit of affordable HbA1c measurement with immediate feedback to patients on diabetes control and related outcomes. We consecutively enrolled patients with diabetes mellitus independently of the type of disease. We hypothesised an average 1%-decrease in HbA1c in a 1000-patient study population, with a 20% increase in the number of patients reaching treatment goals within 12 months of intervention and follow-up. A total of 1, 349 diabetic patients aged 56.2±12.6 years are enrolled (813 in Cameroon and 536 in Guinea) of whom 59.8% are women. The mean duration of diabetes is 7.4±6.3 years and baseline HbA1c is 9.7±2.6% in Guinea and 8.6±2.5% in Cameroon. To investigate whether the introduction of routine HbA1c measurement with immediate feedback to patients and provision of relevant education would improve diabetes control after one year. The impact of the intervention on diabetes associated-complications and mortality warrant further assessment in the long term.

  20. Risk assessment and HbA1c measurement in Norwegian community pharmacies to identify people with undiagnosed type 2 diabetes - A feasibility study.

    Science.gov (United States)

    Risøy, Aslaug Johanne; Kjome, Reidun Lisbet Skeide; Sandberg, Sverre; Sølvik, Una Ørvim

    2018-01-01

    Determine the feasibility of using a diabetes risk assessment tool followed by HbA1c-measurement in a community-pharmacy setting in Norway. In this longitudinal study two pharmacists in each of three community pharmacies were trained to perform risk assessments, HbA1c-measurements and counselling. Pharmacy customers who were > 18 years old and could understand and speak Norwegian or English were recruited in the pharmacies during a two-months-period. Information about the service was presented in local newspapers, social media, leaflets and posters at the pharmacy. Customers wishing to participate contacted the pharmacy staff. Participants completed a validated diabetes risk test and a background questionnaire including a validated instrument for self-rated health. A HbA1c measurement was performed for individuals with a moderate to high risk of developing diabetes. If HbA1c ≥ 6.5% they were recommended to visit their general practitioner for follow-up. The pharmacies performed internal and external quality control of the HbA1c instrument. Of the 211 included participants 97 (46%) were > 50 years old. HbA1c was measured for the 47 participants (22%) with high risk. Thirty-two (15%) had HbA1c values HbA1c ≥ 6.5%. Two participants with HbA1 ≥ 6.5% were diagnosed with diabetes by their general practitioner. The third was lost to follow-up. Results from internal and external quality control for HbA1c were within set limits. The pharmacists were able to perform the risk assessment and measurement of HbA1c, and pharmacy customers were willing to participate. The HbA1c measurements fulfilled the requirements for analytical quality. Thus, it is feasible to implement this service in community pharmacies in Norway. In a large-scale study the inclusion criteria should be increased to 45 years in accordance with the population the risk test has been validated for.

  1. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    Directory of Open Access Journals (Sweden)

    Vani Chandrashekar

    2016-01-01

    Full Text Available Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman’s rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to study the difference in Hb A1c between patients with normal hemoglobin and hemoglobin traits. A total of 431 patients were studied. There was positive correlation with age in patients with normal chromatograms only. No correlation was seen in Hb E trait or beta thalassemia trait. No significant difference in Hb A1c of patients with normal chromatograms and patients with hemoglobin traits was seen. There is no interference by abnormal hemoglobin in the detection of A1c by high performance liquid chromatography. This method cannot be used for detection of A1c in compound heterozygous and homozygous disorders.

  2. A novel double heterozygous Hb Fontainebleau/HbD Punjab hemoglobinopathy.

    Science.gov (United States)

    Rodríguez-Capote, Karina; Estey, Mathew P; Barakauskas, Vilte; Bordeleau, Pierre; Christensen, Cathie-Lou; Zuberbuhler, Peter; Higgins, Trefor N

    2015-09-01

    To report the finding of a novel double heterozygous hemoglobinopathy, the coinheritance of Hb Fontainebleau (α-chain variant) with HbD-Punjab (β-chain variant) discovered upon investigation of unexplained microcytosis in an infant. Hemoglobinopathy investigation was performed by high performance liquid chromatography (HPLC) using the β-thalassemia Short Program on the Bio-Rad Variant II(TM) followed by gel electrophoresis at alkaline and acid pH (Sebia Hydrasys 2 Electrophoresis System) and molecular diagnostic testing. This study complied with our institutional board ethics requirements. HPLC and electrophoresis suggested a complex α- and β-chain hemoglobinopathy with presumptive identification of the beta Hb variant as Hb D-Punjab. DNA sequencing analysis revealed the presence of a double heterozygous status for Hb Fontainebleau/Hb D-Punjab. In this paper we report the coinheritance of Hb Fontainebleau with Hb D-Punjab. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Comparison of the characteristics of two hemoglobin variants, Hb D-Iran and Hb E, eluting in the Hb A2 window.

    Science.gov (United States)

    Dass, Jasmita; Gupta, Aastha; Mittal, Suchi; Saraf, Amrita; Langer, Sabina; Bhargava, Manorama

    2017-06-01

    Cation exchange-high performance liquid chromatography (CE-HPLC) is most commonly used to evaluate hemoglobin (Hb) variants, which elute in the Hb A2 window. This study aimed to assess prevalence of an uncommon Hb variant, Hb D-Iran, and compare its red cell parameters and peak characteristics with those of Hb E that commonly elutes in the Hb A2 window. Generally, we assess abnormal Hb using CE-HPLC as the primary technique along with alkaline and acid electrophoresis. All cases with Hb A2 window >9%, as assessed by CE-HPLCs during 2009-2013, were selected. Twenty-nine cases with Hb D-Iran variant were identified-25 heterozygous, 2 homozygous, 1 compound heterozygous Hb D-Iran/β-thalassemia, and 1 Hb D-Iran/Hb D-Punjab. Overall prevalence of Hb D-Iran was 0.23%. Compared to patients with Hb E, those with Hb D-Iran had significantly higher Hb (12.1 vs. 11.3 g/dL, P =0.03), MCV (82.4 vs. 76.4 fL, P =0.0044), MCH (27.9 vs. 25.45 pg, P =0.0006), and MCHC (33.9 vs. 33.3 g/dL, P =0.0005). Amount of abnormal Hb (40.7 vs. 26.4%, P =0.0001) was significantly higher while retention time (3.56 vs. 3.70 min, P =0.0001) was significantly lower in Hb D-Iran than in Hb E. Hb D-Iran peak can be easily missed if area and retention time of the Hb A2 window are not carefully analyzed. To distinguish between variants, careful analysis of peak area and retention time is sufficient in most cases and may be further confirmed by the second technique-alkaline electrophoresis.

  4. Adduction of acrylamide with biomacromolecules at environmental dose level measured by accelerator mass spectrometry (AMS)

    International Nuclear Information System (INIS)

    Xie, Q.Y.; Sun, H.F.; Liu, Y.F.; Ding, X.F.; Fu, D.P.; Liu, K.X.

    2005-01-01

    Acrylamide (AA) is a well-known neurotoxin, which also has developmental, reproductive as well as genetic toxicity. AA has been classified as a probable human carcinogen by IARC in 1994 since its carcinogenic effects in animals were reported after repetitive high level dosing. Over the last 10 years, there have been a large number of studies investigating the effects of AA on rodent reproductive performance. In 2002, the Swedish Food Administration reported the presence of AA in the heat-treated food products. which again elicited great concern on the toxicity of AA. However most of these studies were investigated at a dose level of mg/kg b.w and above, which is much higher than the actual human relevant dose. In this study we investigate the adduction of environmental level AA with biomacromolecules by the ultra-sensitive AMS technique. This may provide some information on the reproductive toxicity of AA under extremely low level exposure. A series doses of [2, 3- 14 C] AA (0, 0.1, 1, 10, 100, 250, 1000 μg/kg bw) were administrated with a single intraperitoneal injection (i.p.) to ICR adult male mice. The blood and spermatozoon were collected 24 h post dosing. Hemoglobin (Hb), serum albumin (SA), protamine, spermatozoon DNA, spermatozoon head and tail were isolated respectively, and then transformed into graphite following our previous procedure, The adduct levels were determined by a 0.6 MV compact AMS facility at the Institute of Heavy Ion Physics of Peking University. The results indicate that: (1) AA adduct number increases with the doses within 0.1-1000 μg/kg b.w. range in a log/log linear mode, except for DNA within 10-1000 μg/kg b.w. range. (2) Comparing protamine, Hb, and SA adducts with that of spermatozoon DNA (see Fig. 1), AA mainly adducts to proteins. For instance, at 1000 μg/kg b.w. dose level, spermatozoon DNA adducts only account for about 0.71%, 1.36% and 0.82% of protamine, Hb and SA adducts, respectively. (3) AA-protamine adducts, AA

  5. HbA1c Measured in Stored Erythrocytes Is Positively Linearly Associated with Mortality in Individuals with Diabetes Mellitus

    Science.gov (United States)

    Sluik, Diewertje; Boeing, Heiner; Montonen, Jukka; Kaaks, Rudolf; Lukanova, Annekatrin; Sandbaek, Annelli; Overvad, Kim; Arriola, Larraitz; Ardanaz, Eva; Saieva, Calogero; Grioni, Sara; Tumino, Rosario; Sacerdote, Carlotta; Mattiello, Amalia; Spijkerman, Annemieke M. W.; van der A, Daphne L.; Beulens, Joline W. J.; van Dieren, Susan; Nilsson, Peter M.; Groop, Leif C.; Franks, Paul W.; Rolandsson, Olov; Bueno-de-Mesquita, Bas; Nöthlings, Ute

    2012-01-01

    Introduction Observational studies have shown that glycated haemoglobin (HbA1c) is related to mortality, but the shape of the association is less clear. Furthermore, disease duration and medication may modify this association. This observational study explored the association between HbA1c measured in stored erythrocytes and mortality. Secondly, it was assessed whether disease duration and medication use influenced the estimates or were independently associated with mortality. Methods Within the European Prospective Investigation into Cancer and Nutrition a cohort was analysed of 4,345 individuals with a confirmed diagnosis of diabetes at enrolment. HbA1c was measured in blood samples stored up to 19 years. Multivariable Cox proportional hazard regression models for all-cause mortality investigated HbA1c in quartiles as well as per 1% increment, diabetes medication in seven categories of insulin and oral hypoglycaemic agents, and disease duration in quartiles. Results After a median follow-up of 9.3 years, 460 participants died. Higher HbA1c was associated with higher mortality: Hazard Ratio for 1%-increase was 1.11 (95% CI 1.06, 1.17). This association was linear (P-nonlinearity =0.15) and persistent across categories of medication use, disease duration, and co-morbidities. Compared with metformin, other medication types were not associated with mortality. Longer disease duration was associated with mortality, but not after adjustment for HbA1c and medication. Conclusion This prospective study showed that persons with lower HbA1c had better survival than those with higher HbA1c. The association was linear and independent of disease duration, type of medication use, and presence of co-morbidities. Any improvement of HbA1c appears to be associated with reduced mortality risk. PMID:22719972

  6. Advanced glycation end products, measured in skin, vs. HbA1c in children with type 1 diabetes mellitus.

    Science.gov (United States)

    Banser, Alena; Naafs, Jolanda C; Hoorweg-Nijman, Jantine Jg; van de Garde, Ewoudt Mw; van der Vorst, Marja Mj

    2016-09-01

    Advanced glycation end products (AGEs) are considered major contributors to microvascular and macrovascular complications in adult patients with diabetes mellitus. AGEs can be measured non-invasively with skin autofluorescence (sAF). The primary aim was to determine sAF values in children with type 1 diabetes mellitus and to study correlations between sAF values and HbA1c and mean HbA1c over the year prior to measurement In children with type 1 diabetes mellitus, sAF values were measured using the AGE Reader®. Laboratory and anthropometric values were extracted from medical charts. Correlations were studied using Pearson's correlation coefficient. Multivariable linear regression analysis was conducted to evaluate the effect of multiple study parameters on sAF values. The mean sAF value was 1.33 ± 0.36 arbitrary units (AU) in children with type 1 diabetes mellitus (n = 144). sAF values correlated positively with HbA1c measured at the same time (r = 0.485; p 1), mean HbA1c over the year prior to measurement (r = 0.578; p 1), age (r = 0.337; p 1), duration of type 1 diabetes mellitus (r = 0.277; p = 0.001), serum triglycerides (r = 0.399; p 1), and total cholesterol (r = 0.352; p = 0.001). sAF values were significantly higher in patients with non-white skin (1.56 vs. 1.27 AU, respectively, p = 0.001). In children with type 1 diabetes, sAF values correlate strongly with single HbA1c and mean HbA1c, making the non-invasive sAF measurement an interesting alternative to provide information about cumulative hyperglycemic states. To determine the value of sAF measurement in predicting long-term microvascular and macrovascular complications, further prospective follow-up studies are needed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Glycated hemoglobin HbA1c, waist circumference, and waist-to-height ratio in overweight and obese adolescents

    Directory of Open Access Journals (Sweden)

    Elysa Nur Safrida

    2017-04-01

    Full Text Available Background Central obesity has been associated with a high risk of insulin resistance. Waist circumference and waist-to-height ratio are anthropometric indices for determining central obesity and have been associated with increased blood pressure, cholesterol, and insulin levels. In adults, fat distribution around the waist is a valid predictor of glycated hemoglobin (HbA1clevels, and is currently recommended by experts as a diagnostic tool for diabetes. Central obesity measurement has advantages over fasting blood glucose and oral glucose tolerance tests, as it is simple and inexpensive to perform. Objective To assess for correlations between HbA1c level and waist circumference as well as waist-to-height ratio and to assess factors potentially associated with HbA1c levels in overweight and obese adolescents. Methods This cross-sectional study was done in four junior high schools in Yogyakarta, which were obtained by cluster sampling. Overweight and obese students who were generally healthy were included in the study. Subjects underwent waist circumference and waist-to-height ratio measurements, as well as blood tests for HbA1clevels. Results Sixty-seven children participated in the study, with 48 girls (71.6% and 19 boys (28.4%. Waist circumference and HbA1c levels were not significantly associated (r=0.178; P=0.15. However, waist-to-height ratio and HbA1c levels had a weak positive correlation (r=0.21; P=0.04. Linear regression analysis revealed that waist-to-height ratio had a significant association with HbA1c level (P=0.02, but age, sex, and nutritional status did not. Conclusion Waist-to-height ratio is correlated with HbA1c levels in overweight and obese adolescents.

  8. Risk assessment and HbA1c measurement in Norwegian community pharmacies to identify people with undiagnosed type 2 diabetes – A feasibility study

    Science.gov (United States)

    Kjome, Reidun Lisbet Skeide; Sandberg, Sverre; Sølvik, Una Ørvim

    2018-01-01

    Objectives Determine the feasibility of using a diabetes risk assessment tool followed by HbA1c-measurement in a community-pharmacy setting in Norway. Methods In this longitudinal study two pharmacists in each of three community pharmacies were trained to perform risk assessments, HbA1c-measurements and counselling. Pharmacy customers who were > 18 years old and could understand and speak Norwegian or English were recruited in the pharmacies during a two-months-period. Information about the service was presented in local newspapers, social media, leaflets and posters at the pharmacy. Customers wishing to participate contacted the pharmacy staff. Participants completed a validated diabetes risk test and a background questionnaire including a validated instrument for self-rated health. A HbA1c measurement was performed for individuals with a moderate to high risk of developing diabetes. If HbA1c ≥ 6.5% they were recommended to visit their general practitioner for follow-up. The pharmacies performed internal and external quality control of the HbA1c instrument. Results Of the 211 included participants 97 (46%) were > 50 years old. HbA1c was measured for the 47 participants (22%) with high risk. Thirty-two (15%) had HbA1c values internal and external quality control for HbA1c were within set limits. Conclusion The pharmacists were able to perform the risk assessment and measurement of HbA1c, and pharmacy customers were willing to participate. The HbA1c measurements fulfilled the requirements for analytical quality. Thus, it is feasible to implement this service in community pharmacies in Norway. In a large-scale study the inclusion criteria should be increased to 45 years in accordance with the population the risk test has been validated for. PMID:29474501

  9. The Properties of Red Blood Cells from Patients Heterozygous for HbS and HbC (HbSC Genotype

    Directory of Open Access Journals (Sweden)

    A. Hannemann

    2011-01-01

    Full Text Available Sickle cell disease (SCD is one of the commonest severe inherited disorders, but specific treatments are lacking and the pathophysiology remains unclear. Affected individuals account for well over 250,000 births yearly, mostly in the Tropics, the USA, and the Caribbean, also in Northern Europe as well. Incidence in the UK amounts to around 12–15,000 individuals and is increasing, with approximately 300 SCD babies born each year as well as with arrival of new immigrants. About two thirds of SCD patients are homozygous HbSS individuals. Patients heterozygous for HbS and HbC (HbSC constitute about a third of SCD cases, making this the second most common form of SCD, with approximately 80,000 births per year worldwide. Disease in these patients shows differences from that in homozygous HbSS individuals. Their red blood cells (RBCs, containing approximately equal amounts of HbS and HbC, are also likely to show differences in properties which may contribute to disease outcome. Nevertheless, little is known about the behaviour of RBCs from HbSC heterozygotes. This paper reviews what is known about SCD in HbSC individuals and will compare the properties of their RBCs with those from homozygous HbSS patients. Important areas of similarity and potential differences will be emphasised.

  10. Detection of Hb Constant Spring (HBA2: c.427T>C) Heterozygotes in Combination with β-Thalassemia or Hb E Trait by Capillary Electrophoresis.

    Science.gov (United States)

    Pornprasert, Sakorn; Saoboontan, Supansa; Punyamung, Manoo

    2015-01-01

    Hb Constant Spring (Hb CS; HBA2: c.427T>C) is often missed by routine laboratory testing as its mRNA as well as gene product are unstable and presented at a low level in peripheral blood. This study aimed to analyze the efficacy of capillary electrophoresis (CE) for detecting and quantifying of Hb CS in β-thalassemia (β-thal) trait or Hb E (HBB: c.79G>A) trait samples with reduced β-globin chain expression. Thalassemia diagnostic data were reviewed in 2524 blood samples that were submitted to the laboratory of the Associated Medical Sciences Clinical Service Center, Chiang Mai, Thailand for hemoglobinopathy and thalassemia diagnosis. DNA analysis for Hb CS was performed in 322 β-thal trait and 397 Hb E trait samples using the amplification refractory mutation system (ARMS). The CE electropherogram of Hb CS at zone 2 was observed in all five samples with β-thal trait and nine samples with Hb E trait with levels varying from 0.1-2.8 and 0.1-2.3%, respectively. Thus, the CE method proved useful for screening of Hb CS in samples with β-thal trait or Hb E trait, which is essential for providing accurate diagnosis, genetic counseling, prevention and control programs of Hb H-CS disease.

  11. Stability study for magnetic reagent assaying Hb and HbA1c

    International Nuclear Information System (INIS)

    Hsieh, Wen-Pin; Chieh, J.J.; Yang, C.C.; Yang, S.Y.; Chen, Po-Yu; Huang, Yu-Hao; Hong, Y.W.; Horng, H.E.

    2013-01-01

    Reagents for magnetically labeled immunoassay on human Hb and human HbA1c have been synthesized. The reagents consist of Fe 3 O 4 magnetic particles biofunctionalized with antibodies against Hb and HbA1c. It has been demonstrated that the reagents can be applied to quantitatively detect Hb and HbA1c by using immunomagnetic reduction assay. In addition to characterizing the assay properties, such as the standard curve and the low-detection limit, the stability of reagents is investigated. To do this, the temporal dependence of particle sizes and the bio-activity of reagents are monitored. The results show that the reagents are highly stable when stored at 2–8 °C. This means that the reagents synthesized in this work are promising for practical applications. - Highlights: ► The properties of assaying Hb and HbA1c using immunomagnetic reduction are studied. ► The magnetic nanoparticles with antibodies are highly stable in solutions. ► No significant mutual interference between Hb and HbA1c in assays is observed. ► High-sensitivity assays on Hb and HbA1c using immunomagnetic reduction are achieved.

  12. Dietary fiber intake is associated with HbA1c level among prevalent patients with type 2 diabetes in Pudong New Area of Shanghai, China.

    Directory of Open Access Journals (Sweden)

    Junyi Jiang

    Full Text Available BACKGROUND: Dietary factors play an important role in glycemic control in diabetic patients. However, little is known about their effects among Chinese diabetic patients, whose diets are typically abundant in fiber and high in glycemic index (GI values. METHODOLOGY/PRINCIPAL FINDINGS: 934 patients with type 2 diabetes and 918 healthy volunteers from Pudong New Area, Shanghai, China, were interviewed during the period of Oct-Dec, 2006 to elicit demographic characteristics and lifestyle factors. Dietary habits were assessed using a validated food frequency questionnaire. Anthropometric measurements, bio-specimen collection and biochemical assays were conducted at the interview according to a standard protocol. In this population, diabetic patients consumed lower levels of energy and macronutrients but had higher levels of fasting plasma glucose (FPG, glycolated hemoglobin A1c (HbA1c, triglyceride and body mass index than healthy adults. While the average consumption levels of the nutrients among diabetic patients did not vary along duration of the disease, the average levels of FPG and HbA1c increased with increasing duration. Regardless of diabetes duration, HbA1c level was observed lower in patients having a higher fiber or lower GI intake. Compared with those with the lowest tertile intake of fiber, the adjusted odds ratios (ORs for poor glycemic control reduced from 0.75 (95%CI: 0.54-1.06 to 0.51 (95%CI: 0.34-0.75 with increasing tertile intake (P for trend <0.001. CONCLUSIONS: Dietary fiber may play an important role in reducing HbA1c level. Increasing fiber intake may be an effective approach to improve glycemic control among Chinese diabetic patients.

  13. Use of Fructosyl Peptide Oxidase for HbA1c Assay

    Science.gov (United States)

    Yonehara, Satoshi; Inamura, Norio; Fukuda, Miho; Sugiyama, Koji

    2015-01-01

    ARKRAY, Inc developed the world’s first automatic glycohemoglobin analyzer based on HPLC (1981). After that, ARKRAY developed enzymatic HbA1c assay “CinQ HbA1c” with the spread and diversification of HbA1c measurement (2007). CinQ HbA1c is the kit of Clinical Chemistry Analyzer, which uses fructosyl peptide oxidase (FPOX) for a measurement reaction. This report mainly indicates the developmental background, measurement principle, and future of the enzymatic method HbA1c reagent. PMID:25633966

  14. [Evaluation of DCA vantage for rapid in-clinic measurement of HbA1c on capillary blood in young type 1 diabetic patients].

    Science.gov (United States)

    El Arabi, H; Willems, D; Mélot, C; Dorchy, H

    2013-01-01

    Rapid in clinic measurement of glycated hemoglogin (HbA1c) allows to determine the level of metabolic control within a few minutes on capillary blood. We have evaluated the new DCA Vantage (Siemens) based on an immunological technique, replacing the DCA 2000+ (Siemens). The study included 120 unselected young type 1 diabetic patients, with different degrees of metabolic control. The DCA Vantage was compared with the HPLC system (Menarini HA 8160) whose deviation from the DCCT was Vantage was -0.40%. The agreement limits (+/- 1.96 SD) were between 0.14% and -0.93%; this means +/- 0.53% around -0.40%. In conclusion, the DCA Vantage underestimates HbA1c levels; however it met the acceptance criteria of having a coefficient of variation < 3%.

  15. Role of HbA1c in the Screening of Diabetes Mellitus in a Korean Rural Community

    Directory of Open Access Journals (Sweden)

    Jae Hyun Kim

    2012-02-01

    Full Text Available BackgroundRecently, the measurement of glycated hemoglobin (HbA1c was recommended as an alternative to fasting plasma glucose or oral glucose tolerance tests for diagnosing diabetes mellitus (DM. In this study, we analyzed HbA1c levels for diabetes mellitus screening in a Korean rural population.MethodsWe analyzed data from 10,111 subjects from a Korean Rural Genomic Cohort study and generated a receiver operating characteristic curve to determine an appropriate HbA1c cutoff value for diabetes.ResultsThe mean age of the subjects was 56.3±8.1 years. Fasting plasma glucose and 2-hour plasma glucose after 75 g oral glucose tolerance tests were 97.5±25.6 and 138.3±67.1 mg/dL, respectively. The mean HbA1c level of the subjects was 5.7±0.9%. There were 8,809 non-DM patients (87.1% and 1,302 DM patients (12.9%. A positive relationship between HbA1c and plasma glucose levels and between HbA1c and 2-hour plasma glucose levels after oral glucose tolerance tests was found in a scatter plot of the data. Using Youden's index, the proper cutoff level of HbA1c for diabetes mellitus screening was 5.95% (sensitivity, 77%; specificity, 89.4%.ConclusionOur results suggest that the optimal HbA1c level for DM screening is 5.95%.

  16. Stability study for magnetic reagent assaying Hb and HbA1c

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Wen-Pin [Actherm Inc., Hsinchu 200, Taiwan (China); Chieh, J.J.; Yang, C.C. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Yang, S.Y. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); MagQu Co., Ltd., Sindian Dist., New Taipei City 231, Taiwan (China); Chen, Po-Yu; Huang, Yu-Hao [Actherm Inc., Hsinchu 200, Taiwan (China); Hong, Y.W. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E., E-mail: phyfv001@ntnu.edu.tw [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)

    2013-01-15

    Reagents for magnetically labeled immunoassay on human Hb and human HbA1c have been synthesized. The reagents consist of Fe{sub 3}O{sub 4} magnetic particles biofunctionalized with antibodies against Hb and HbA1c. It has been demonstrated that the reagents can be applied to quantitatively detect Hb and HbA1c by using immunomagnetic reduction assay. In addition to characterizing the assay properties, such as the standard curve and the low-detection limit, the stability of reagents is investigated. To do this, the temporal dependence of particle sizes and the bio-activity of reagents are monitored. The results show that the reagents are highly stable when stored at 2-8 Degree-Sign C. This means that the reagents synthesized in this work are promising for practical applications. - Highlights: Black-Right-Pointing-Pointer The properties of assaying Hb and HbA1c using immunomagnetic reduction are studied. Black-Right-Pointing-Pointer The magnetic nanoparticles with antibodies are highly stable in solutions. Black-Right-Pointing-Pointer No significant mutual interference between Hb and HbA1c in assays is observed. Black-Right-Pointing-Pointer High-sensitivity assays on Hb and HbA1c using immunomagnetic reduction are achieved.

  17. Implementation and effectiveness of sound mitigation measures on Texas highways (HB 790) : final report.

    Science.gov (United States)

    2016-10-01

    The 84th Texas Legislature passed House Bill (HB) 790 directing the Texas A&M Transportation Institute (TTI) to perform a study on the implementation and effectiveness of sound mitigation measures on the state highway system and certain toll roads an...

  18. Are Ethnic Disparities in HbA1c Levels Explained by Mental Wellbeing? Analysis of Population-Based Data from the Health Survey for England.

    Science.gov (United States)

    Umeh, Kanayo

    2018-02-01

    It is unclear how ethnic differences in HbA 1c levels are affected by individual variations in mental wellbeing. Thus, the aim of this study was to assess the extent to which HbA 1c disparities between Caucasian and South Asian adults are mediated by various aspects of positive psychological functioning. Data from the 2014 Health Survey for England was analysed using bootstrapping methods. A total of 3894 UK residents with HbA 1c data were eligible to participate. Mental wellbeing was assessed using the Warwick-Edinburgh Mental Well-being Scale. To reduce bias BMI, blood pressure, diabetes status, and other factors were treated as covariates. Ethnicity directly predicted blood sugar control (unadjusted coefficient -2.15; 95% CI -3.64, -0.67), with Caucasians generating lower average HbA 1c levels (37.68 mmol/mol (5.6%)) compared to South Asians (39.87 mmol/mol (5.8%)). This association was mediated by positive mental wellbeing, specifically concerning perceived vigour (unadjusted effect 0.30; 95% CI 0.13, 0.58): South Asians felt more energetic than Caucasians (unadjusted coefficient -0.32; 95% CI -0.49, -0.16), and greater perceived energy predicted lower HbA 1c levels (unadjusted coefficient -0.92; 95% CI -1.29, -0.55). This mediator effect accounted for just over 14% of the HbA 1c variance and was negated after adjusting for BMI. Caucasian experience better HbA 1c levels compared with their South Asian counterparts. However, this association is partly confounded by individual differences in perceived energy levels, which is implicated in better glycaemic control, and appears to serve a protective function in South Asians.

  19. Oxidized LDL but not total LDL is associated with HbA1c in individuals without diabetes.

    Science.gov (United States)

    Spessatto, Débora; Brum, Liz Marina Bueno Dos Passos; Camargo, Joíza Lins

    2017-08-01

    This study investigates the association between HbA1c, LDL and oxi-LDL in individuals without diabetes (DM). One hundred and ninety-six individuals, without DM, were enrolled and divided into three groups according to HbA1c and fasting plasma glucose values. HbA1c, oxi-LDL, LDL, and other biochemical measurements of lipid profile were also carried out. oxi-LDL levels showed significant differences among all groups and group 3 presented higher values [34U/L (27-46); 44U/L (37-70); and 86U/L (49-136); pHbA1c showed moderate positive associations with oxi-LDL (r=0.431; pHbA1c and TC (r=0.142; p=0.048), triglycerides (r=0.155; p=0.030), LDL (r=0.148; p=0.039), non-HDL (r=0.192; p=0.007) and Apo B (r=0.171, pHbA1c and oxi-LDL, oxi-LDL/HDL and oxi-LDL/LDL ratios remained significant even after adjustment by multiple linear regression analysis for the variables alcohol consumption, use of medicine, BMI, and age. oxi-LDL levels are significantly associated with HbA1c in non-diabetic individuals. However, the levels of traditional atherogenic lipids only showed a weak association with HbA1c levels. Those at high risk of developing DM or cardiovascular disease have higher levels of oxi-LDL. These data favor to the use of HbA1c as a biomarker to identify individuals at risk of developing complications even in non-diabetic glycemic levels. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Prevalence of anxiety and depression among diabetic African patients in Guinea: association with HbA1c levels.

    Science.gov (United States)

    Camara, A; Baldé, N M; Enoru, S; Bangoura, J S; Sobngwi, E; Bonnet, F

    2015-02-01

    The prevalence and risk factors associated with symptoms of anxiety and depression were determined in African people with diabetes. This cross-sectional study involved 491 outpatients with type 2 diabetes (T2D) recruited from four diabetes clinics (Conakry, Labé, Boké and Kankan) in Guinea. The Hospital Anxiety and Depression Scale (HADS) was used to evaluate symptoms of anxiety and depression. Logistic regression analysis stratified by gender was performed to identify the associated risk factors. Anxiety and depression symptoms were present in 58.7% and 34.4%, respectively, of the 491 patients with T2D (62.7% women, mean±SD age: 57.9±10.2years). Odds ratios (95% CI) of risk factors independently associated with anxiety were urban residence [2.98 (1.81-4.89)] in women, and low socioeconomic status [0.19 (0.05-0.70)] and HbA1c≥9.0% [2.61 (1.0-6.39)] in men. Factors associated with depression were urban residence [2.13 (1.27-3.58)], older age [1.03 (1.01-1.06)], low socioeconomic status [2.21 (1.34-3.66)] and no previous measurement of HbA1c [12.45 (1.54-100.34)] in women, and insulin therapy [2.28 (1.05-4.92)] and HbA1c≥9.0% [3.85 (1.02-14.48)] in men. Anxiety and depression symptoms in people with type T2D are common in Guinea. Urban residence, low socioeconomic status and high levels of HbA1c were significantly associated with a greater risk of anxiety and depression, highlighting the psychological burden related to diabetes in Africa. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. The preoperative HbA1c level is an independent prognostic factor for the postoperative survival after resection of non-small cell lung cancer in elderly patients.

    Science.gov (United States)

    Motoishi, Makoto; Sawai, Satoru; Hori, Tetsuo; Yamashita, Naoki

    2018-05-01

    The aim of this study was to investigate the influence of a history of diabetes mellitus (DM) and the glycated hemoglobin (HbA1c) level on the survival in patients who underwent complete resection for non-small cell lung cancer (NSCLC). Of the patients who underwent complete resection for NSCLC between 2007 and 2015, 468 were classified into DM (who were currently taking medication for DM) and no DM groups as well as into high HbA1c (≥ 6.5) and normal HbA1c (HbA1c group than in the high-HbA1c group (5-year survival rate: 84.7 versus 37.2%, respectively, p HbA1c level were found to be independent risk factors for the OS. We revealed that a high preoperative HbA1c level was associated with a poor OS in elderly patients who underwent complete resection for NSCLC. This suggests that it is necessary to achieve diabetic control prior to complete resection in NSCLC patients.

  2. HbA1c level cannot predict the treatment outcome of smear-positive non-multi-drug-resistant HIV-negative pulmonary tuberculosis inpatients

    Science.gov (United States)

    Tashiro, Ken; Horita, Nobuyuki; Nagai, Kenjiro; Ikeda, Misako; Shinkai, Masaharu; Yamamoto, Masaki; Sato, Takashi; Hara, Yu; Nagakura, Hideyuki; Shibata, Yuji; Watanabe, Hiroki; Nakashima, Kentaro; Ushio, Ryota; Nagashima, Akimichi; Narita, Atsuya; Kobayashi, Nobuaki; Kudo, Makoto; Kaneko, Takeshi

    2017-01-01

    We conducted a single-center retrospective cohort study to evaluate whether the HbA1c level on admission could predict the in-hospital treatment outcome of smear-positive non-multi-drug-resistant HIV-negative culture-proven pulmonary tuberculosis inpatients. Our standard regimens under the direct observation were HRZE or HRE for the first two months followed by combination therapy with isoniazid and rifampicin. Our cohort consisted of consecutive 239 patients consisted of 147 men and 92 women with a median age of 73 years. The HbA1c level of patients whose HbA1c was above 7.0% on admission showed clear declining trends after admission. HbA1c on admission had no Spearman’s rank correlation with time to discharge alive (r = 0.17) and time to becoming non-infective (r = 0.17). By Kaplan-Meier curves and a log-rank trend test, HbA1c quartile subgroups showed no association with times to discharge alive (p = 0.431), becoming non-infective (p = 0.113), and in-hospital death (p = 0.427). Based on multi-variate Cox analysis, HbA1c on admission had no significant impact on time to discharge alive (hazard ratio = 1.03, 95% CI 0.89–1.20, p = 0.659), becoming non-infective (hazard ratio = 0.93, 95% CI 0.80–1.06, p = 0.277), and in-hospital death (hazard ratio = 0.68, 0.43–1.07, p = 0.097). In conclusion, the HbA1c level on admission did not seem to affect in-hospital tuberculosis treatment outcomes in Japanese cohort. PMID:28406247

  3. Extreme Levels of HbA1c Increase Incident ESRD Risk in Chinese Patients with Type 2 Diabetes: Competing Risk Analysis in National Cohort of Taiwan Diabetes Study

    Science.gov (United States)

    Liu, Chiu-Shong; Huang, Chiu-Ching; Lin, Wen-Yuan; Chiang, Jen-Huai; Lin, Cheng-Chieh; Li, Tsai-Chung

    2015-01-01

    Background Whether HbA1c is a predictor of end-stage renal disease (ESRD) in type 2 diabetes patients remains unclear. This study evaluated relationship between HbA1c and ESRD in Chinese patients with type 2 diabetes. Methods Patients aged ≥ 30 years who were free of ESRD (n = 51 681) were included from National Diabetes Care Management Program from 2002–2003. Extended Cox proportional hazard model with competing risk of death served to evaluate association between HbA1c level and ESRD. Results A total of 2613 (5.06%) people developed ESRD during a follow-up period of 8.1 years. Overall incidence rate of ESRD was 6.26 per 1000 person-years. Patients with high levels of HbA1c had a high incidence rate of ESRD, from 4.29 for HbA1c of  6.0%–6.9% to 10.33 for HbA1c ≥ 10.0% per 1000 person-years. Patients with HbA1c HbA1c  of 6.0%–6.9%. A J-shaped relationship between HbA1c level and ESRD risk was observed. After adjustment, patients with HbA1c HbA1c of 6.0%–6.9%. Conclusions Diabetes care has focused on preventing hyperglycemia, but not hypoglycemia. Our study revealed that HbA1c level ≥ 7.0% was linked with increased ESRD risk in type 2 diabetes patients, and that HbA1c HbA1c targets and improve outcomes without increasing the risk to this population. Clinicians need to pay attention to HbA1c results on diabetic nephropathy. PMID:26098901

  4. The 1-hour post-load glucose level is more effective than HbA1c for screening dysglycemia.

    Science.gov (United States)

    Jagannathan, Ram; Sevick, Mary Ann; Fink, Dorothy; Dankner, Rachel; Chetrit, Angela; Roth, Jesse; Buysschaert, Martin; Bergman, Michael

    2016-08-01

    To assess the performance of HbA1c and the 1-h plasma glucose (PG ≥ 155 mg/dl; 8.6 mmol/l) in identifying dysglycemia based on the oral glucose tolerance test (OGTT) from a real-world clinical care setting. This was a diagnostic test accuracy study. For this analysis, we tested the HbA1c diagnostic criteria advocated by the American Diabetes Association (ADA 5.7-6.4 %) and International Expert Committee (IEC 6.0-6.4 %) against conventional OGTT criteria. We also tested the utility of 1-h PG ≥ mg/dl; 8.6 mmol/l. Prediabetes was defined according to ADA-OGTT guidelines. Spearman correlation tests were used to determine the relationships between HbA1c, 1-h PG with fasting, 2-h PG and indices of insulin sensitivity and β-cell function. The levels of agreement between diagnostic methods were ascertained using Cohen's kappa coefficient (Κ). Receiver operating characteristic (ROC) curve was used to analyze the performance of the HbA1c and 1-h PG test in identifying prediabetes considering OGTT as reference diagnostic criteria. The diagnostic properties of different HbA1c thresholds were contrasted by determining sensitivity, specificity and likelihood ratios (LR). Of the 212 high-risk individuals, 70 (33 %) were identified with prediabetes, and 1-h PG showed a stronger association with 2-h PG, insulin sensitivity index, and β-cell function than HbA1c (P HbA1c criteria 0.1[0.03-0.16] and IEC criteria (0.17[0.04-0.30]). The ROC (AUC[95 % CI]) for HbA1c and 1-h PG were 0.65[0.57-0.73] and 0.79[0.72-0.85], respectively. Importantly, 1-h PG ≥ 155 mg/dl (8.6 mmol/l) showed good sensitivity (74.3 % [62.4-84.0]) and specificity 69.7 % [61.5-77.1]) with a LR of 2.45. The ability of 1-h PG to discriminate prediabetes was better than that of HbA1c (∆AUC: -0.14; Z value: 2.5683; P = 0.01022). In a real-world clinical practice setting, the 1-h PG ≥ 155 mg/dl (8.6 mmol/l) is superior for detecting high-risk individuals compared with HbA1c

  5. Serum testosterone levels of HbSS (sickle cell disease male subjects in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Adediran Adewumi

    2011-08-01

    Full Text Available Abstract Background Infertility is a major problem in sickle cell disease patients, especially in males. In addition to low serum testosterone, other abnormalities involving the accessory sex organs, such as the seminal vesicles and the prostate gland, as well as marked decrease in ejaculate volume may be observed in male HbSS patients. Hence, the need to study the role of sex hormones as a cause of infertility in male HbSS patients. Methods An unmatched case-control study was performed using seventy-five consenting subjects from Lagos University Teaching Hospital. These included 47 patients with haemoglobin phenotype SS from the Sickle cell clinic and 28 volunteered medical students and members of staff with haemoglobin phenotype AA. Demographic data were obtained using a self-administered questionnaire. A total of 5 mls of blood was collected from each subject between 9.00 am & 11.am, and assayed for serum testosterone concentration. Results The concentrations of serum testosterone in HbSS patients ranged from 0.2 to 4.3 ng/ml with a mean of 1.28 ± 0.72 ng/ml whilst the values in HbAA controls ranged from 1.2 to 6.9 ng/ml with a mean of 2.63 ± 1.04 ng/ml. Seven (25.0% of the 28 controls had serum testosterone concentration lower than the quoted reference (normal range whereas 44 (93.6% of the 47 HbSS subjects had serum testosterone concentration lower than the reference range. Conclusion Overall, subjects with HbSS have significantly lower mean serum testosterone than HbAA controls.

  6. Cation Homeostasis in Red Cells From Patients With Sickle Cell Disease Heterologous for HbS and HbC (HbSC Genotype

    Directory of Open Access Journals (Sweden)

    A. Hannemann

    2015-11-01

    Full Text Available Sickle cell disease (SCD in patients of HbSC genotype is considered similar, albeit milder, to that in homozygous HbSS individuals — but with little justification. In SCD, elevated red cell cation permeability is critical as increased solute loss causes dehydration and encourages sickling. Recently, we showed that the KCl cotransporter (KCC activity in red cells from HbSC patients correlated significantly with disease severity, but that in HbSS patients did not. Two transporters involved in red cell dehydration, the conductive channels Psickle and the Gardos channel, behaved similarly in red cells from the two genotypes, but were significantly less active in HbSC patients. By contrast, KCC activity was quantitatively greater in HbSC red cells. Results suggest that KCC is likely to have greater involvement in red cell dehydration in HbSC patients, which could explain its association with disease severity in this genotype. This work supports the hypothesis that SCD in HbSC patients is a distinct disease entity to that in HbSS patients. Results suggest the possibility of designing specific treatments of particular benefit to HbSC patients and a rationale for the development of prognostic markers, to inform early treatment of children likely to develop more severe complications of the disease.

  7. Identifying the independent effect of HbA1c variability on adverse health outcomes in patients with Type 2 diabetes.

    Science.gov (United States)

    Prentice, J C; Pizer, S D; Conlin, P R

    2016-12-01

    To characterize the relationship between HbA 1c variability and adverse health outcomes among US military veterans with Type 2 diabetes. This retrospective cohort study used Veterans Affairs and Medicare claims for veterans with Type 2 diabetes taking metformin who initiated a second diabetes medication (n = 50 861). The main exposure of interest was HbA 1c variability during a 3-year baseline period. HbA 1c variability, categorized into quartiles, was defined as standard deviation, coefficient of variation and adjusted standard deviation, which accounted for the number and mean number of days between HbA 1c tests. Cox proportional hazard models predicted mortality, hospitalization for ambulatory care-sensitive conditions, and myocardial infarction or stroke and were controlled for mean HbA 1c levels and the direction of change in HbA 1c levels during the baseline period. Over a mean 3.3 years of follow-up, all HbA 1c variability measures significantly predicted each outcome. Using the adjusted standard deviation measure for HbA 1c variability, the hazard ratios for the third and fourth quartile predicting mortality were 1.14 (95% CI 1.04, 1.25) and 1.42 (95% CI 1.28, 1.58), for myocardial infarction and stroke they were 1.25 (95% CI 1.10, 1.41) and 1.23 (95% CI 1.07, 1.42) and for ambulatory-care sensitive condition hospitalization they were 1.10 (95% CI 1.03, 1.18) and 1.11 (95% CI 1.03, 1.20). Higher baseline HbA 1c levels independently predicted the likelihood of each outcome. In veterans with Type 2 diabetes, greater HbA 1c variability was associated with an increased risk of adverse long-term outcomes, independently of HbA 1c levels and direction of change. Limiting HbA 1c fluctuations over time may reduce complications. © 2016 Diabetes UK.

  8. Glycated haemoglobin (HbA1c), diabetes and trajectories of change in episodic memory performance.

    Science.gov (United States)

    Pappas, Colleen; Andel, Ross; Infurna, Frank J; Seetharaman, Shyam

    2017-02-01

    As the ageing population grows, it is important to identify strategies to moderate cognitive ageing. We examined glycated haemoglobin (HbA1c) and diabetes in relation to level and change in episodic memory in older adults with and without diabetes. Data from 4419 older adults with (n=950) and without (n=3469) diabetes participating in a nationally representative longitudinal panel study (the Health and Retirement Study) were examined. Average baseline age was 72.66 years and 58% were women. HbA1c was measured in 2006 and episodic memory was measured using immediate and delayed list recall over 4 biennial waves between 2006 and 2012. Growth curve models were used to assess trajectories of episodic memory change. In growth curve models adjusted for age, sex, education, race, depressive symptoms and waist circumference, higher HbA1c levels and having diabetes were associated with poorer baseline episodic memory (p=0.036 and HbA1c on episodic memory decline was smaller than the effect of age. The results were stronger for women than men and were not modified by age or race. When the main analyses were estimated for those with and without diabetes separately, HbA1c was significantly linked to change in episodic memory only among those with diabetes. Higher HbA1c and diabetes were both associated with declines in episodic memory, with this relationship further exacerbated by having diabetes and elevated HbA1c. HbA1c appeared more important for episodic memory performance among women than men. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Comparison of 1,5-anhydroglucitol, HbA1c, and fructosamine for detection of diabetes mellitus.

    Science.gov (United States)

    Yamanouchi, T; Akanuma, Y; Toyota, T; Kuzuya, T; Kawai, T; Kawazu, S; Yoshioka, S; Kanazawa, Y; Ohta, M; Baba, S

    1991-01-01

    To evaluate the use of serum 1,5-anhydroglucitol (AG) levels in screening for diabetes mellitus, we compared the sensitivity and specificity of HbA1c, fructosamine (FA), and AG in 1620 randomly selected subjects in 11 institutions throughout Japan. Most individuals were receiving diet and/or drug therapy for diabetes. Subjects were separated into four groups based on World Health Organization criteria: nondiabetic control subjects, subjects with impaired glucose tolerance (IGT), patients with diabetes, and patients with other disorders without IGT. The overlap of AG values between each group was less than that of HbA1c or FA values. AG levels were significantly correlated with fasting plasma glucose (r = -0.627), HbA1c (r = -0.629), and FA (r = -0.590) levels. If we took 14 micrograms/ml as the normal lower limit, AG level was highly specific (93.1%), and a decreased AG level indicated diabetes mellitus (84.2% sensitivity). According to the selectivity index (sensitivity value times specificity value), AG determinations were superior to both HbA1c and FA measurements for diabetes screening. When combinations of these tests were used, only AG and HbA1c together were slightly better than AG alone. Thus, together with other advantages of AG, e.g., its wide variance with relatively fair glycemic control and the negligible influence of the sampling conditions, AG level has more potential than HbA1c or FA level as a screening criterion for diabetes.

  10. Effects of common hemoglobin variants on HbA1c measurements in China: results for α- and β-globin variants measured by six methods.

    Science.gov (United States)

    Xu, Anping; Chen, Weidong; Xia, Yong; Zhou, Yu; Ji, Ling

    2018-04-07

    HbA1c is a widely used biomarker for diabetes mellitus management. Here, we evaluated the accuracy of six methods for determining HbA1c values in Chinese patients with common α- and β-globin chains variants in China. Blood samples from normal subjects and individuals exhibiting hemoglobin variants were analyzed for HbA1c, using Sebia Capillarys 2 Flex Piercing (C2FP), Bio-Rad Variant II Turbo 2.0, Tosoh HLC-723 G8 (ver. 5.24), Arkray ADAMS A1c HA-8180V fast mode, Cobas c501 and Trinity Ultra2 systems. DNA sequencing revealed five common β-globin chain variants and three common α-globin chain variants. The most common variant was Hb E, followed by Hb New York, Hb J-Bangkok, Hb G-Coushatta, Hb Q-Thailand, Hb G-Honolulu, Hb Ube-2 and Hb G-Taipei. Variant II Turbo 2.0, Ultra2 and Cobas c501 showed good agreement with C2FP for most samples with variants. HLC-723 G8 yielded no HbA1c values for Hb J-Bangkok, Hb Q-Thailand and Hb G-Honolulu. Samples with Hb E, Hb G-Coushatta, Hb G-Taipei and Hb Ube-2 produced significant negative biases for HLC-723 G8. HA-8180V showed statistically significant differences for Hb E, Hb G-Coushatta, Hb G-Taipei, Hb Q-Thailand and Hb G-Honolulu. HA-8180V yielded no HbA1c values for Hb J-Bangkok. All methods showed good agreement for samples with Hb New York. Some common hemoglobin variants can interfere with HbA1c determination by the most popular methods in China.

  11. Requirements Doc for Refurb of JASPER Facility in B131HB

    Energy Technology Data Exchange (ETDEWEB)

    Knittel, Kenn M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-01-25

    The Joint Actinide Shock Physics Experimental Research (JASPER) Program target fabrication facility is currently located in building 131 (B131) of the Lawrence Livermore National Laboratory (LLNL). A portion of this current facility has been committed to another program as part of a larger effort to consolidate LLNL capabilities into newer facilities. This facility assembles precision targets for scientific studies at the Nevada National Security Site (NNSS). B131 is also going through a modernization project to upgrade the infrastructure and abate asbestos. These activities will interrupt the continuous target fabrication efforts for the JASPER Program. Several options are explored to meet the above conflicting requirements, with the final recommendation to prepare a new facility for JASPER target fabrication operations before modernization efforts begin in the current facility assigned to JASPER. This recommendation fits within all schedule constraints and minimizes the disruption to the JASPER Program. This option is not without risk, as it requires moving an aged, precision coordinate measuring machine, which is essential to the JASPER Program’s success. The selected option balances the risk to the machine with continuity of operations.

  12. To establish trimester-specific reference ranges for glycated haemoglobin (HbA1c) in pregnancy

    LENUS (Irish Health Repository)

    O'Connor, CM

    2011-09-01

    Background and aims: Diabetes in Pregnancy imposes additional risks to both mother and infant. These poor outcomes are considered to be primarily related to glycaemic control which is monitored longitudinally through pregnancy by means of HbA1c. The correlation between HbA1c levels with clinical outcomes emphasises the need to measure HbA1c accurately, precisely and for data interpretation comparison to appropriately defined reference intervals. From July 1st 2010, the HbA1c assay in Irish laboratories became fully metrologically traceable to the IFCC standard, permitting HbA1c to be reported in IFCC units (mmol\\/mol) and derived DCCT\\/NGSP units (%) using the IFCC-DCCT\\/NGSP master equation (DCCT = Diabetes Control and Complications Trial, NGSP = National Glycohemoglobin standardisation program). The aim of this project is to establish trimester-specific reference ranges in pregnancy for IFCC standardised HbA1c in non-diabetic Caucasian women. This will allow us to define the goal for HbA1c during pregnancy complicated by diabetes.\\r\

  13. Common Hemoglobin Variants in Southern Taiwan and Their Effect on the Determination of HbA1c by Ion-exchange High-performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Chih-Hsun Chu

    2009-07-01

    Conclusion: The existence of Hb variants may result in false HbA1c measurement. The possible presence of spuriously low HbA1c levels or abnormal HPLC chromatograms by using ion-exchange methods should be kept in mind.

  14. Maternal Hb during pregnancy and offspring's educational achievement: a prospective cohort study over 30 years.

    Science.gov (United States)

    Fararouei, Mohammad; Robertson, Claire; Whittaker, John; Sovio, Ulla; Ruokonen, Aimo; Pouta, Anneli; Hartikainen, Anna-Liisa; Jarvelin, Marjo-Riitta; Hyppönen, Elina

    2010-11-01

    The aim of the present study was to examine the association between maternal Hb levels during pregnancy and educational achievement of the offspring in later life. We analysed data obtained from the Northern Finnish Birth Cohort Study conducted in 1966, in which, data on mothers and offspring from pregnancy through to the age of 31 years were collected. The cohort comprised 11 656 individuals born from singleton births (51 % males and 49 % females). Maternal Hb levels were available from the third, seventh and ninth gestational months. Educational achievement was measured as school scores (range 4-10) taken at the ages of 14 (self-reported questionnaires) and 16 (school reports) years as well as the highest level of education at the age of 31 years. The present results showed a direct positive association between Hb levels and educational achievement in later life. After adjustment for sex, birth weight, birth month and a wide range of maternal factors (parity, smoking, mental status, whether pregnancy was wanted or not, education, social class and marital status), only maternal Hb levels that were measured at the ninth month were significantly associated with the offspring's school performance. If the levels were ≥ 110 g/l at all the three measurement points, offspring not only had better school scores at the ages of 14 and 16 years (β = 0·048, P = 0·04 and β = 0·68, P = 0·007, respectively), but also had an increased odds of having a higher level of education at the age of 31 years (OR = 1·14, P = 0·04). The present study suggests that low maternal Hb levels at the final stages of pregnancy are linked to the poorer educational achievement of the offspring. If our observation is confirmed, it would suggest that Fe prophylaxis even at fairly late stages of pregnancy may be beneficial for the subsequent health of the offspring. However, more studies are needed to fully establish the potential pathways and the clinical importance of the

  15. Safety analysis, 200 Area, Savannah River Plant: Separations area operations. Building 221-H, B-Line, Scrap Recovery Facility (Supplement 2A): Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1991-07-01

    The now HB-Line is located an top of the 221-H Building on the fifth and sixth levels and is designed to replace the aging existing HB-Line production facility. The new HB-Line consists of three separate facilities: the Scrap Recovery Facility, Neptunium Facility, and Plutonium Oxide Facility. The Scrap Recovery Facility is designed to routinely generate nitrate solutions of {sup 235}U{sup 239}Pu and Pu-238 fromscrap for purification by anion exchange or by solvent extraction in the canyon. The now facility incorporates improvements in: (1) engineered controls for nuclear criticality, (2) cabinet integrity and engineered barriers to contain contamination and minimize personnel exposure to airborne contamination, (3) shielding and remote operations to decrease radiation exposure, and (4) equipment and ventilation design to provide flexibility and improved process performance.

  16. Should Studies of Diabetes Treatment Stratification Correct for Baseline HbA1c?

    Science.gov (United States)

    Jones, Angus G.; Lonergan, Mike; Henley, William E.; Pearson, Ewan R.; Hattersley, Andrew T.; Shields, Beverley M.

    2016-01-01

    Aims Baseline HbA1c is a major predictor of response to glucose lowering therapy and therefore a potential confounder in studies aiming to identify other predictors. However, baseline adjustment may introduce error if the association between baseline HbA1c and response is substantially due to measurement error and regression to the mean. We aimed to determine whether studies of predictors of response should adjust for baseline HbA1c. Methods We assessed the relationship between baseline HbA1c and glycaemic response in 257 participants treated with GLP-1R agonists and assessed whether it reflected measurement error and regression to the mean using duplicate ‘pre-baseline’ HbA1c measurements not included in the response variable. In this cohort and an additional 2659 participants treated with sulfonylureas we assessed the relationship between covariates associated with baseline HbA1c and treatment response with and without baseline adjustment, and with a bias correction using pre-baseline HbA1c to adjust for the effects of error in baseline HbA1c. Results Baseline HbA1c was a major predictor of response (R2 = 0.19,β = -0.44,pHbA1c were associated with response, however these associations were weak or absent after adjustment for baseline HbA1c. Bias correction did not substantially alter associations. Conclusions Adjustment for the baseline HbA1c measurement is a simple and effective way to reduce bias in studies of predictors of response to glucose lowering therapy. PMID:27050911

  17. Cross-sectional comparison of point-of-care with laboratory HbA1c in detecting diabetes in real-world remote Aboriginal settings

    Science.gov (United States)

    Marley, Julia V; Oh, May S; Hadgraft, Nyssa; Singleton, Sally; Isaacs, Kim; Atkinson, David

    2015-01-01

    Objectives To determine if point-of-care (POC) glycated haemoglobin (HbA1c) is sufficiently accurate in real-world remote settings to predict or exclude the diagnosis of diabetes based on laboratory HbA1c measurements. Design Cross-sectional study comparing POC capillary HbA1c results with corresponding venous HbA1c levels measured in a reference laboratory. Participants Aboriginal patients ≥15 years old who were due for diabetes screening at the participating clinics were invited to participate. Two hundred and fifty-five Aboriginal participants were enrolled and 241 were included in the analysis. Setting 6 primary healthcare sites in the remote Kimberley region of Western Australia from September 2011 to November 2013. Main outcome measures Concordance and mean differences between POC capillary blood HbA1c measurement and laboratory measurement of venous blood HbA1c level; POC capillary blood HbA1c equivalence value for screening for diabetes or a high risk of developing diabetes; sensitivity, specificity and positive-predictive value for diagnosing and screening for diabetes; barriers to conducting POC testing. Results Concordance between POC and laboratory results was good (ρ=0.88, pHbA1c measurements ≥6.5%, 48 mmol/mol had a specificity of 98.2% and sensitivity of 73.7% for laboratory measurements ≥6.5%. The POC equivalence value for screening for diabetes or a high risk of developing diabetes was ≥5.7%, 39 mmol/mol (sensitivity, 91%; specificity, 76.7% for laboratory measurements ≥6.0%, 42 mmol/mol). Staff trained by other clinic staff ‘on the job’ performed as well as people with formal accredited training. Staff reported difficulty in maintaining formal accreditation. Conclusions POC HbA1c testing is sufficiently accurate to be a useful component in screening for, and diagnosing, diabetes in remote communities. Limited local training is adequate to produce results comparable to laboratory results and accreditation processes need to

  18. Are There Clinical Implications of Racial Differences in HbA1c? A Difference, to Be a Difference, Must Make a Difference

    Science.gov (United States)

    Selvin, Elizabeth

    2016-01-01

    Studies that have compared HbA1c levels by race have consistently demonstrated higher HbA1c levels in African Americans than in whites. These racial differences in HbA1c have not been explained by measured differences in glycemia, sociodemographic factors, clinical factors, access to care, or quality of care. Recently, a number of nonglycemic factors and several genetic polymorphisms that operate through nonglycemic mechanisms have been associated with HbA1c. Their distributions across racial groups and their impact on hemoglobin glycation need to be systematically explored. Thus, on the basis of evidence for racial differences in HbA1c, current clinical guidelines from the American Diabetes Association state: “It is important to take…race/ethnicity…into consideration when using the A1C to diagnose diabetes.” However, it is not clear from the guidelines how this recommendation might be actualized. So, the critical question is not whether racial differences in HbA1c exist between African Americans and whites; the important question is whether the observed differences in HbA1c level are clinically meaningful. Therefore, given the current controversy, we provide a Point-Counterpoint debate on this issue. In the preceding point narrative, Dr. Herman provides his argument that the failure to acknowledge that HbA1c might be a biased measure of average glycemia and an unwillingness to rigorously investigate this hypothesis will slow scientific progress and has the potential to do great harm. In the counterpoint narrative below, Dr. Selvin argues that there is no compelling evidence for racial differences in the validity of HbA1c as a measure of hyperglycemia and that race is a poor surrogate for differences in underlying causes of disease risk. —William T. Cefalu Editor in Chief, Diabetes Care PMID:27457637

  19. Possible discrepancy of HbA1c values and its assessment among patients with chronic renal failure, hemodialysis and other diseases.

    Science.gov (United States)

    Inoue, Kaori; Goto, Atsushi; Kishimoto, Miyako; Tsujimoto, Tetsuro; Yamamoto-Honda, Ritsuko; Noto, Hiroshi; Kajio, Hiroshi; Terauchi, Yasuo; Noda, Mitsuhiko

    2015-12-01

    Glycated hemoglobin (HbA1c) and glycated albumin (GA) are frequently used as glycemic control markers. However, these markers are influenced by alterations in hemoglobin and albumin metabolism. Thus, conditions such as anemia, chronic renal failure, hypersplenism, chronic liver diseases, hyperthyroidism, hypoalbuminemia, and pregnancy need to be considered when interpreting HbA1c or GA values. Using data from patients with normal albumin and hemoglobin metabolism, we previously established a linear regression equation describing the GA value versus the HbA1c value to calculate an extrapolated HbA1c (eHbA1c) value for the accurate evaluation of glycemic control. In this study, we investigated the difference between the measured HbA1c and the eHbA1c values for patients with various conditions. Data sets for a total of 2461 occasions were obtained from 731 patients whose HbA1c and GA values were simultaneously measured. We excluded patients with missing data or changeable HbA1c levels, and patients who had received transfusions or steroids within the previous 3 months. Finally, we included 44 patients with chronic renal failure (CRF), 10 patients who were undergoing hemodialysis (HD), 7 patients with hematological malignancies and a hemoglobin level of less than 10 g/dL (HM), and 12 patients with chronic liver diseases (CLD). In all the groups, the eHbA1c values were significantly higher than the measured HbA1c values. The median difference was 0.75 % (95 % CI 0.40-1.10 %, P for the difference is <0.001) in the CRF group, 0.80 % (95 % CI 0.30-1.65 %, P for the difference is 0.041) in the HD group, 0.90 % (95 % CI 0.90-1.30 %, P for the difference is 0.028) in the HM group, and 0.85 % (95 % CI 0.40-1.50 %, P for the difference is 0.009) in the CLD group. We found that the measured HbA1c values were lower than the eHbA1c values in each of the groups.

  20. Measurement of HbA1c in multicentre diabetes trials - should blood samples be tested locally or sent to a central laboratory: an agreement analysis.

    Science.gov (United States)

    Arch, Barbara N; Blair, Joanne; McKay, Andrew; Gregory, John W; Newland, Paul; Gamble, Carrol

    2016-10-24

    Glycated haemoglobin (HbA1c) is an important outcome measure in diabetes clinical trials. For multicentre designs, HbA1c can be measured locally at participating centres or by sending blood samples to a central laboratory. This study analyses the agreement between local and central measurements, using 1-year follow-up data collected in a multicentre randomised controlled trial (RCT) of newly diagnosed children with type I diabetes. HbA1c measurements were routinely analysed both locally and centrally at baseline and then at 3, 6, 9 and 12 months and the data reported in mmol/mol. Agreement was assessed by calculating the bias and 95 % limits of agreement, using the Bland-Altman analysis method. A predetermined benchmark for clinically acceptable margin of error between measurements was subjectively set as ±10 % for HbA1c. The percentage of pairs of measurements that were classified as clinically acceptable was calculated. Descriptive statistics were used to examine the agreement within centres. Treatment group was not considered. Five hundred and ninety pairs of measurement, representing 255 children and 15 trial centres across four follow-up time points, were compared. There was no significant bias: local measurements were an average of 0.16 mmol/mol (SD = 4.5, 95 % CI -0.2 to 0.5) higher than central. The 95 % limits of agreement were -8.6 to 9.0 mmol/mol (local minus central). Eighty percent of local measurements were within ±10 % of corresponding central measurements. Some trial centres were more varied in the differences observed between local and central measurements: IQRs ranging from 3 to 9 mmol/mol; none indicated systematic bias. Variation in agreement between HbA1c measurements was greater than had been expected although no overall bias was detected and standard deviations were similar. Discrepancies were present across all participating centres. These findings have implications for the comparison of standards of clinical care between centres

  1. Alternate site testing for HbA1c using the Primus CLC330 GHb analyzer.

    Science.gov (United States)

    Phillipov, G; Charles, P; Beng, C; Phillips, P J

    1997-04-01

    To determine whether the Primus high-pressure liquid chromatography (HPLC) is suited to alternate site testing (AST) for HbA1c in a hospital diabetes outpatient clinic. Patients were attending the clinic for routine management of their diabetes. A number of diabetic patients with uremia (n = 11) were also investigated. HbA1c levels were measured in the outpatient setting by the Primus HPLC and in a more limited study the DCA-2000 instrument using the new 6-min assay cartridge. HbA1c measurements were also performed with Pierce affinity minicolumns and a Bio-Rad Variant HPLC. The Primus HPLC assay had low imprecision of 2.3, 1.6, and 1.0% for HbA1c levels of 4.7, 7.3, and 11.1%, respectively, and was not prone to interference by carbamylated hemoglobin as found for the ion-exchange Variant HPLC method. Method comparison studies showed that the bias and proportional error between the Pierce affinity minicolumn procedure (standardized with respect to an external quality control program) and the Primus HPLC (Y) was -0.4 and 1.2% respectively (n = 32). Similarly the bias and proportional error between the Primus and DCA-2000 methods was 0.7 and -2.5%. The Primus was shown to give falsely elevated HbA1c concentrations if the time between sequential injections was > 28 min. The Primus HPLC has a decided advantage over specialty AST instruments, like the DCA-2000, in not only meeting AST requirements but also allowing rapid automated batch processing of all laboratory HbA1c samples.

  2. Low oxygen saturation and severe anemia in compound heterozygous Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val].

    Science.gov (United States)

    Kamseng, Parin; Trakulsrichai, Satariya; Trachoo, Objoon; Yimniam, Walaiporn; Panthan, Bhakbhoom; Jittorntam, Paisan; Niparuck, Pimjai; Sanguanwit, Pitsucha; Wananukul, Winai; Jindadamrongwech, Sumalee

    2017-03-01

    To investigate the cause(s) of a Thai male proband presenting low oxygen saturation by pulse oximetry (SpO 2 ) and severe anemia. As Hb variant was suspected, Hb typing was determined by high-performance liquid chromatography and capillary electrophoresis, and subsequently Hb variant was identified by DNA sequencing. Complete blood counts were performed using automated blood cell counter and oxygen saturation was measured by pulse oximetry. Proband was compound heterozygous for Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val]. Of the proband's two sons, one was compound heterozygous for Hb Louisville and Hb E and the other for Hb La Desirade and Hb E. The former son had similar clinical features and laboratory findings with those of the proband while the latter showed had no abnormal clinical manifestations. This the first report of compound heterozygosity of Hb Louisville and Hb La Desirade in an individual of Southeast Asian ethnicity. Hb variant identification is crucial for genetic counseling and appropriate treatment in regions where hemoglobinopathies are common.

  3. Effects of dapagliflozin on insulin-requirement, glucose excretion and ß-hydroxybutyrate levels are not related to baseline HbA1c in youth with type 1 diabetes.

    Science.gov (United States)

    Biester, Torben; Aschemeier, Baerbel; Fath, Maryam; Frey, Marcel; Scheerer, Markus F; Kordonouri, Olga; Danne, Thomas

    2017-11-01

    Youth with type 1 diabetes (T1D) infrequently achieve HbA1c targets. Therefore, this placebo-controlled, randomized, crossover study was set up to assess the safety, effect and pharmacokinetics of a single dose of 10 mg dapagliflozin (DAPA) as add-on to insulin in relationship to HbA1c in youth. A total of 33 youths (14 males, median age 16 years, diabetes duration 8 years) were included and stratified into 3 baseline HbA1c categories (9.0; n = 11 each). During the study period of 24 hours, intravenous insulin administration and glucose-infusion kept blood glucose levels at 160 to 220 mg/dL. DAPA reduced mean insulin dose by 13.6% ( P  HbA1c. Six independent episodes in 6 patients with plasma ß-hydroxybutyrate levels between ≥0.6 and HbA1c levels, for adjunct SGLT2-inhibitor therapy in the paediatric age group by lowering insulin dose and increasing glucose excretion. © 2017 John Wiley & Sons Ltd.

  4. Association between blood glucose level derived using the oral glucose tolerance test and glycated hemoglobin level.

    Science.gov (United States)

    Kim, Hyoung Joo; Kim, Young Geon; Park, Jin Soo; Ahn, Young Hwan; Ha, Kyoung Hwa; Kim, Dae Jung

    2016-05-01

    Glycated hemoglobin (HbA1c) is widely used as a marker of glycemic control. Translation of the HbA1c level to an average blood glucose level is useful because the latter figure is easily understood by patients. We studied the association between blood glucose levels revealed by the oral glucose tolerance test (OGTT) and HbA1c levels in a Korean population. A total of 1,000 subjects aged 30 to 64 years from the Cardiovascular and Metabolic Diseases Etiology Research Center cohort were included. Fasting glucose levels, post-load glucose levels at 30, 60, and 120 minutes into the OGTT, and HbA1c levels were measured. Linear regression of HbA1c with mean blood glucose levels derived using the OGTT revealed a significant correlation between these measures (predicted mean glucose [mg/dL] = 49.4 × HbA1c [%] - 149.6; R (2) = 0.54, p Glucose (ADAG) study and Diabetes Control and Complications Trial (DCCT) cohort. Discrepancies between our results and those of the ADAG study and DCCT cohort may be attributable to differences in the test methods used and the extent of insulin secretion. More studies are needed to evaluate the association between HbA1c and self monitoring blood glucose levels.

  5. Effect of Ramadan fasting on glucose level, lipid profile, HbA1c and uric acid among medical students in Karachi, Pakistan.

    Science.gov (United States)

    Khan, Nazeer; Rasheed, Abdur; Ahmed, Hassaan; Aslam, Faiza; Kanwal, Fatima

    2017-06-14

    To assess the effect of Ramadan fasting on blood pressure, fasting glucose, lipid profile, uric acid, HbA1c, body mass index, body adiposity index and visceral adiposity index among fasting medical students, 35 students were recorded before, during and after Ramadan (August) 2011, for their blood pressure, anthropometric measurements, questionnaire response and blood sample. A blood sample was taken at each visit for glucose, lipid profile and HbA1c. Total physical activity, weight-to-height ratio, body adiposity index and visceral adiposity index were calculated for insulin sensitivity. Changes in anthropometric measurements were not statistically significant. However, physical activities increased significantly after Ramadan. Changes in blood pressure, fasting blood sugar, total cholesterol, HbA1c, uric acid and triglyceride were not statistically significant. Mean high density lipoprotein decreased significantly in Ramadan, while low density lipoprotein increased significantly.

  6. The efficacy of black cumin seed (Nigella sativa) oil and hypoglycemic drug combination to reduce HbA1c level in patients with metabolic syndrome risk

    Science.gov (United States)

    Rachman, P. N. R.; Akrom; Darmawan, E.

    2017-11-01

    Metabolic syndrome is a conditions caused by metabolic abnormalities include central obesity, atherogenic dyslipidemia, hypertension, and insulin resistance. HbA1c examination is required to study the long-term glycemic status and to prevent diabetic complications of metabolic syndrome. The purpose of this study is to determine the efficacy of black cumin seed (Nigella sativa) oil and hypoglycemic drug combination to reduce HbA1c level in patients with metabolic syndrome risk. This research performed using an experimental randomized single - blind controlled trial design. A total of 99 outpatients at the Jetis I Public Health Center, Yogyakarta, Indonesia with metabolic syndrome risk were divided into three groups: The control group received placebo and two treatment groups received black seed oil orally at dose of 1.5 mL/day and 3 mL/day, respectively, for 20 days. The clinical conditions such as blood pressure, pulse rate, BMI, blood glucose serum and HbA1c levels were examined on day 0 and 21. The results obtained were analyzed with one-way ANOVA test. The mean of HbA1c levels of all groups before treatment was higher than the normal values and there was no significant difference in HbA1c value on day 0. Administration of 1.5 and 3 mL/day of black seed oil for 20 days decreased (padministration of black cumin seed oil and hypoglycemic drug combination for 20 days in patients at risk of metabolic syndrome may reduce to HbA1c levels.

  7. Inhibition of Hb Binding to GP1bα Abrogates Hb-Mediated Thrombus Formation on Immobilized VWF and Collagen under Physiological Shear Stress.

    Science.gov (United States)

    Annarapu, Gowtham K; Singhal, Rashi; Peng, Yuandong; Guchhait, Prasenjit

    2016-01-01

    Reports including our own describe that intravascular hemolysis increases the risk of thrombosis in hemolytic disorders. Our recent study shows that plasma Hb concentrations correlate directly with platelet activation in patients with paroxysmal nocturnal hemoglobinuria (PNH). The binding of Hb to glycoprotein1bα (GP1bα) increases platelet activation. A peptide AA1-50, designed from N-terminal amino acid sequence of GP1bα significantly inhibits the Hb binding to GP1bα as well as Hb-induced platelet activation. This study further examined if the Hb-mediated platelet activation plays any significant role in thrombus formation on subendothelium matrix under physiological flow shear stresses and the inhibition of Hb-platelet interaction can abrogate the above effects of Hb. Study performed thrombus formation assay in vitro by perfusing whole blood over immobilized VWF or collagen type I in presence of Hb under shear stresses simulating arterial or venous flow. The Hb concentrations ranging from 5 to 10 μM, commonly observed level in plasma of the hemolytic patients including PNH, dose-dependently increased thrombus formation on immobilized VWF under higher shear stress of 25 dyne/cm2, but not at 5 dyne/cm2. The above Hb concentrations also increased thrombus formation on immobilized collagen under both shear stresses of 5 and 25 dyne/cm2. The peptide AA1-50 abrogated invariably the above effects of Hb on thrombus formation. This study therefore indicates that the Hb-induced platelet activation plays a crucial role in thrombus formation on immobilized VWF or collagen under physiological flow shear stresses. Thus suggesting a probable role of this mechanism in facilitating thrombosis under hemolytic conditions.

  8. Diagnosis of a rare double heterozygous Hb D Punjab/Hb Q India hemoglobinopathy using Sebia capillary zone electrophoresis

    Directory of Open Access Journals (Sweden)

    Sushama Parab

    2014-01-01

    Full Text Available In India, hemoglobinopathies constitute a major genetic disorder and hemoglobin variants such as Hb S, Hb D Punjab, and Hb E are the most common ones. Other variants include Hb Q India, Hb Lepore, Hb J Meerut, Hb D Iran, etc. These variants show heterozygous state along with beta thalassemia. However, compound heterozygosities among these variants are very rare. Ethylenediaminetetraacetic acid whole blood sample received for routine thalassemia screening was subjected to alkaline electrophoresis using automated capillary zone electrophoresis. Suspecting the presence of rare variants, further analysis was carried out using Bio-Rad D10 and Tosoh G8 high-performance liquid chromatography (HPLC systems. Capillary zone electrophoretograms showed the presence of peaks in zone Hb A, Hb D, a fused peak in Hb A2, and a small peak in Z1 zone. Bio-Rad and Tosoh chromatograms also indicated the presence of four peaks which are identified as Hb A, Hb D Punjab, Hb Q India, and hybrid of Hb D Punjab/Hb Q India. A peak in Hb D zone of capillary was due to co-migration of Hb D Punjab and Hb Q India variants. Small peak in Z1 zone indicated the presence of alpha chain variant Hb Q India. The findings were further confirmed by HPLC results and molecular genetic studies. The present study reports for the 1 st time a rare hemoglobinopathy of double heterozygosity for Hb D Punjab, Hb Q India on Capillarys 2 Flex Piercing analyzer and is forth reported case for this rare hemoglobinopathy.

  9. Liquid level measurement in high level nuclear waste slurries

    International Nuclear Information System (INIS)

    Weeks, G.E.; Heckendorn, F.M.; Postles, R.L.

    1990-01-01

    Accurate liquid level measurement has been a difficult problem to solve for the Defense Waste Processing Facility (DWPF). The nuclear waste sludge tends to plug or degrade most commercially available liquid-level measurement sensors. A liquid-level measurement system that meets demanding accuracy requirements for the DWPF has been developed. The system uses a pneumatic 1:1 pressure repeater as a sensor and a computerized error correction system. 2 figs

  10. The Fallacy of Average: How Using HbA1c Alone to Assess Glycemic Control Can Be Misleading.

    Science.gov (United States)

    Beck, Roy W; Connor, Crystal G; Mullen, Deborah M; Wesley, David M; Bergenstal, Richard M

    2017-08-01

    HbA 1c is a v aluable metric for comparing treatment groups in a randomized trial, for assessing glycemic trends in a population over time, or for cross-sectional comparisons of glycemic control in different populations. However, what is not widely appreciated is that HbA 1c may not be a good indicator of an individual patient's glycemic control because of the wide range of mean glucose concentrations and glucose profiles that can be associated with a given HbA 1c level. To illustrate this point, we plotted mean glucose measured with continuous glucose monitoring (CGM) versus central laboratory-measured HbA 1c in 387 participants in three randomized trials, showing that not infrequently HbA 1c may underestimate or overestimate mean glucose, sometimes substantially. Thus, if HbA 1c is to be used to assess glycemic control, it is imperative to know the patient's actual mean glucose to understand how well HbA 1c is an indicator of the patient's glycemic control. With knowledge of the mean glucose, an estimated HbA 1c (eA1C) can be calculated with the formula provided in this article to compare with the measured HbA 1c . Estimating glycemic control from HbA 1c alone is in essence applying a population average to an individual, which can be misleading. Thus, a patient's CGM glucose profile has considerable value for optimizing his or her diabetes management. In this era of personalized, precision medicine, there are few better examples with respect to the fallacy of applying a population average to a specific patient rather than using specific information about the patient to determine the optimal approach to treatment. © 2017 by the American Diabetes Association.

  11. Intake of Vitamin and Mineral Supplements and Longitudinal Association with HbA1c Levels in the General Non-Diabetic Population--Results from the MONICA/KORA S3/F3 Study.

    Directory of Open Access Journals (Sweden)

    Sigrid Schwab

    Full Text Available Lower levels of hemoglobin A1c (HbA1c are associated with a decreased risk of cardiovascular complications in diabetic and non-diabetic individuals. The aim of the study was to longitudinally investigate the association between the use of 11 vitamins and minerals (vitamins E, C, D, B1, folic acid, carotenoids, calcium, magnesium, zinc, iron, and selenium and change in HbA1c levels over 10 years in non-diabetic individuals drawn from the general population.Baseline data were available from 4447 subjects included in the population-based "Monitoring of Trends and Determinants in Cardiovascular Diseases" (MONICA Augsburg S3 survey (1994/95. Follow-up data were derived from 2774 participants in the follow-up survey named "Cooperative Health Research in the Region of Augsburg" (KORA F3 (2004/05. Vitamin/mineral intake from supplements and medications was assessed in a personal interview, where participants were asked to bring product packages of preparations that had been ingested during the last 7 days prior to the examination. Associations between regular vitamin/mineral intake amounts and HbA1c levels measured at baseline and follow-up were investigated using generalized estimating equation models. For carotenoids, analyses were stratified by smoking status.None of the investigated nutrients except for carotenoids was significantly associated with changes in HbA1c levels after 10 years. Regular intake of carotenoids from supplements and medications in amounts > 6.8 mg/d (upper tertile was associated with an absolute -0.26% (95% CI: -0.43 to -0.08 lower increase in HbA1c levels compared with no intake of carotenoids. An inverse association was observed in those who never smoked but not in (former smokers.Larger prospective and intervention studies in non-diabetic/non-smoking individuals are needed to confirm the results and to assess whether the observed associations between carotenoid intake and change in HbA1c levels are causal. If our results are

  12. Effect of Education of Self-care Behaviors on HbA1C level in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Ahmadi Zakieh

    2016-06-01

    Full Text Available Background and Objective: The successful glycemic control in diabetic patients is very important. Since the poor self-care is reported as the most important causes of mortality and complications, therefore these patients require self-care knowledge. This study aimed to determine the effect of education of self-care behaviors on HbA1C level in diabetic patients. Materials and Method: In this clinical trial, 80 diabetic patients referred to the diabetes clinic in Bandar Abbas were selected through random sampling and then were randomly allocated into two groups of intervention and control based on stratified random sampling. Designed educational program was implemented in 9 sessions (60 minutes, once a week for 12 weeks for patients in the intervention group. Patients in the control group were received usual care of clinic. Data were collected through using demographic information form and HbA1c test. Data were collected at the beginning of the study and 12 weeks after the intervention. Data were analyzed by SPSS software (version 18 using independent T- test, paired T-test, Mann-Whitney U and chi-square. Results: Before the intervention, the HbA1c average in the intervention and control groups was 8.18 ± 1.66 and 8.41 ± 2.10, respectively and after the intervention these values were changed to 7.78 ± 1.48 and 8.82 ± 2.11 in the intervention and control groups respectively (p = 0.01. Conclusion: Implementation of educational program of self-care behaviors was effective in reducing HbA1C and it can be used as an appropriate educational method by nurses and other health care team in controlling of diabetes in patients.

  13. Significance of HbA1c and its measurement in the diagnosis of diabetes mellitus: US experience.

    Science.gov (United States)

    Juarez, Deborah Taira; Demaris, Kendra M; Goo, Roy; Mnatzaganian, Christina Louise; Wong Smith, Helen

    2014-01-01

    The 2014 American Diabetes Association guidelines denote four means of diagnosing diabetes. The first of these is a glycosylated hemoglobin (HbA1c) >6.5%. This literature review summarizes studies (n=47) in the USA examining the significance, strengths, and limitations of using HbA1c as a diagnostic tool for diabetes, relative to other available means. Due to the relatively recent adoption of HbA1c as a diabetes mellitus diagnostic tool, a hybrid systematic, truncated review of the literature was implemented. Based on these studies, we conclude that HbA1c screening for diabetes has been found to be convenient and effective in diagnosing diabetes. HbA1c screening is particularly helpful in community-based and acute care settings where tests requiring fasting are not practical. Using HbA1c to diagnose diabetes also has some limitations. For instance, HbA1c testing may underestimate the prevalence of diabetes, particularly among whites. Because this bias differs by racial group, prevalence and resulting estimates of health disparities based on HbA1c screening differ from those based on other methods of diagnosis. In addition, existing evidence suggests that HbA1c screening may not be valid in certain subgroups, such as children, women with gestational diabetes, patients with human immunodeficiency virus, and those with prediabetes. Further guidelines are needed to clarify the appropriate use of HbA1c screening in these populations.

  14. Hb F Levels in Indian Sickle Cell Patients and Association with the HBB Locus Variant rs10128556 (C>T), and the HBG XmnI (Arab-Indian) Variant.

    Science.gov (United States)

    Bhanushali, Aparna A; Himani, Kumari; Patra, Pradeep K; Das, Bibhu R

    The prevalence of sickle cell disease in India is very high. Hb F is one of the most powerful modulators of disease severity in sickle cell disease patients. It was traditionally thought that the disease is milder in Indian sickle cell disease patients predominantly due to the Arab-Indian haplotype characterized by the HBG XmnI [rs7482144 (G>A)] variant, which is associated with increased Hb F levels. In the current study, we investigated the Hb F levels in individuals with the rs10128556 (C>T) variant and also determined its linkage with the HBG XmnI variant. The present study was conducted on a cohort of 275 individuals, which consisted of 221 patients with sickle cell disease and 54 patients with sickle cell trait. Analysis of hemoglobin (Hb) fractions and variants was done on the high performance liquid chromatography (HPLC) system. Genotyping for rs10128556 was done by direct sequencing of the products. Mean Hb F levels in the sickle cell disease patients was 19.36 ± 6.79. The genotypic frequencies for rs10128556 were 82.0% (TT), 16.7% (CT) and 1.3% (CC) for sickle cell disease patients. The minor C allele resulted in 52.0% decrease in Hb F levels when homozygous and 7.0% decrease when heterozygous. The rs10128556 single nucleotide polymorphism (SNP) was in strong but not complete linkage with the HBG XmnI variant. In conclusion, the study determined for the first time the frequency and association of rs10128556 in Indian sickle cell disease patients with Hb F. It also established that it was not in complete linkage with the HBG XmnI variant in this high risk population.

  15. Mechanosensitive promoter region in the human HB-GAM gene

    DEFF Research Database (Denmark)

    Liedert, Astrid; Kassem, Moustapha; Claes, Lutz

    2009-01-01

    Mechanical loading is essential for maintaining bone mass in the adult skeleton. However, the underlying process of the transfer of the physical stimulus into a biochemical response, which is termed mechanotransduction is poorly understood. Mechanotransduction results in the modulation of gene...... cells. Analysis of the human HB-GAM gene upstream regulatory region with luciferase reporter gene assays revealed that the upregulation of HB-GAM expression occurred at the transcriptional level and was mainly dependent on the HB-GAM promoter region most upstream containing three potential AP-1 binding...

  16. Probing the diphosphoglycerate binding pocket of HbA and HbPresbyterian (beta 108Asn --> Lys).

    Science.gov (United States)

    Gottfried, D S; Manjula, B N; Malavalli, A; Acharya, A S; Friedman, J M

    1999-08-31

    HbPresbyterian (beta 108Asn --> Lys, HbP) contains an additional positive charge (per alpha beta dimer) in the middle of the central cavity and exhibits a lower oxygen affinity than wild-type HbA in the presence of chloride. However, very little is known about the molecular origins of its altered functional properties. In this study, we have focused on the beta beta cleft of the Hb tetramer. Recently, we developed an approach for quantifying the ligand binding affinity to the beta-end of the Hb central cavity using fluorescent analogues of the natural allosteric effector 2, 3-diphosphoglycerate (DPG) [Gottfried, D. S., et al. (1997) J. Biol. Chem. 272, 1571-1578]. Time-correlated single-photon counting fluorescence lifetime studies were used to assess the binding of pyrenetetrasulfonate to both HbA and HbP in the deoxy and CO ligation states under acidic and neutral pH conditions. Both the native and mutant proteins bind the probe at a weak binding site and a strong binding site; in all cases, the binding to HbP was stronger than to HbA. The most striking finding was that for HbA the binding affinity varies as follows: deoxy (pH 6.35) > deoxy (pH 7.20) > CO (pH 6.35); however, the binding to HbP is independent of ligation or pH. The mutant oxy protein also hydrolyzes p-nitrophenyl acetate, through a reversible acyl-imidazole pathway linked to the His residues of the beta beta cleft, at a considerably higher rate than does HbA. This implies a perturbation of the microenvironment of these residues at the DPG binding pocket. Structural consequences due to the presence of the new positive charge in the middle of the central cavity have been transmitted to the beta beta cleft of the protein, even in its liganded conformation. This is consistent with a newly described quaternary state (B) for liganded HbPresbyterian and an associated change in the allosteric control mechanism.

  17. Modelling incremental benefits on complications rates when targeting lower HbA1c levels in people with Type 2 diabetes and cardiovascular disease.

    Science.gov (United States)

    Mostafa, S A; Coleman, R L; Agbaje, O F; Gray, A M; Holman, R R; Bethel, M A

    2018-01-01

    Glucose-lowering interventions in Type 2 diabetes mellitus have demonstrated reductions in microvascular complications and modest reductions in macrovascular complications. However, the degree to which targeting different HbA 1c reductions might reduce risk is unclear. Participant-level data for Trial Evaluating Cardiovascular Outcomes with Sitagliptin (TECOS) participants with established cardiovascular disease were used in a Type 2 diabetes-specific simulation model to quantify the likely impact of different HbA 1c decrements on complication rates. Ten-year micro- and macrovascular rates were estimated with HbA 1c levels fixed at 86, 75, 64, 53 and 42 mmol/mol (10%, 9%, 8%, 7% and 6%) while holding other risk factors constant at their baseline levels. Cumulative relative risk reductions for each outcome were derived for each HbA 1c decrement. Of 5717 participants studied, 72.0% were men and 74.2% White European, with a mean (sd) age of 66.2 (7.9) years, systolic blood pressure 134 (16.9) mmHg, LDL-cholesterol 2.3 (0.9) mmol/l, HDL-cholesterol 1.13 (0.3) mmol/l and median Type 2 diabetes duration 9.6 (5.1-15.6) years. Ten-year cumulative relative risk reductions for modelled HbA 1c values of 75, 64, 53 and 42 mmol/mol, relative to 86 mmol/mol, were 4.6%, 9.3%, 15.1% and 20.2% for myocardial infarction; 6.0%, 12.8%, 19.6% and 25.8% for stroke; 14.4%, 26.6%, 37.1% and 46.4% for diabetes-related ulcer; 21.5%, 39.0%, 52.3% and 63.1% for amputation; and 13.6%, 25.4%, 36.0% and 44.7 for single-eye blindness. These simulated complication rates might help inform the degree to which complications might be reduced by targeting particular HbA 1c reductions in Type 2 diabetes. © 2017 Diabetes UK.

  18. Impact of Disease Management Programs on HbA1c Values in Type 2 Diabetes Patients in Germany.

    Science.gov (United States)

    Kostev, Karel; Rockel, Timo; Jacob, Louis

    2017-01-01

    The aim was to analyze the impact of disease management programs on HbA1c values in type 2 diabetes mellitus (T2DM) patients in Germany. This study included 9017 patients followed in disease management programs (DMPs) who started an antihyperglycemic treatment upon inclusion in a DMP. Standard care (SC) patients were included after individual matching (1:1) to DMP cases based on age, gender, physician (diabetologist versus nondiabetologist care), HbA1c values at baseline, and index year. The main outcome was the share of patients with HbA1c HbA1c level as a dependent variable and the potential predictor (DMP versus SC). The mean age was 64.3 years and 54.7% of the patients were men. The mean HbA1c level at baseline was equal to 8.7%. In diabetologist practices, 64.7% of DMP patients and 55.1% of SC patients had HbA1c levels HbA1c levels HbA1c levels HbA1c levels HbA1c levels lower than 7.5% or 6.5% after 6 months of therapy in both diabetologist and general care practices. The present study indicates that the enrollment of T2DM patients in DMPs has a positive impact on HbA1c values in Germany.

  19. Dietary determinants for Hb-acrylamide and Hb-glycidamide adducts in Danish non-smoking women

    DEFF Research Database (Denmark)

    Outzen, Malene; Egeberg, Rikke; Dragsted, Lars

    2011-01-01

    in erythrocytes were analysed by liquid chromatography/MS/MS. Dietary determinants were evaluated by multiple linear regression analyses adjusted for age and smoking behaviour among ex-smokers. The median for Hb-AA was 35 pmol/g globin (5th percentile 17, 95th percentile 89) and for Hb-GA 21 pmol/g globin (5th......Acrylamide (AA) is a probable human carcinogen that is formed in heat-treated carbohydrate-rich foods. The validity of FFQ to assess AA exposure has been questioned. The aim of the present cross-sectional study was to investigate dietary determinants of Hb-AA and Hb-glycidamide (GA) adducts....... The study included 537 non-smoking women aged 50–65 years who participated in the Diet, Cancer and Health cohort (1993–97). At study baseline, blood samples and information on dietary and lifestyle variables obtained from self-administered questionnaires were collected. From blood samples, Hb-AA and Hb-GA...

  20. A Novel Double Heterozygous Hb D-Punjab/Hb J-Meerut Hemoglobinopathy.

    Science.gov (United States)

    Chandra, Dinesh; Tyagi, Seema; Deka, Roopam; Chauhan, Richa; Seth, Tulika; Saxena, Renu; Pati, H P

    2017-12-01

    A comprehensive laboratory diagnosis of hemoglobinopathies forms an integral part in workup of disorders of globin chain synthesis. Clinical findings, complete blood counts, peripheral smear examination along with hemoglobin (Hb) electrophoresis and/or cation exchange high performance liquid chromatography findings and parental study helps to clinch a final diagnosis. Compound heterozygous hemoglobinopathy presents with variable clinical findings and some of them are picked up on screening tests done as part of routine antenatal workup. Here we report a rare double heterozygous hemoglobinopathy of Hb D-Punjab and Hb J-Meerut in a 35 year antenatal female.

  1. Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma?

    Science.gov (United States)

    Lenters-Westra, Erna; Strunk, Annuska; Campbell, Paul; Slingerland, Robbert J

    2017-02-01

    Hb-variant interference when reporting HbA1c has been an ongoing challenge since HbA1c was introduced to monitor patients with diabetes mellitus. Most Hb-variants show an abnormal chromatogram when cation-exchange HPLC is used for the determination of HbA1c. Unfortunately, the Tosoh G8 generates what appears to be normal chromatogram in the presence of Hb-Tacoma, yielding a falsely high HbA1c value. The primary aim of the study was to investigate if the Afinion HbA1c point-of-care (POC) instrument could be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma. Whole blood samples were collected in K 2 EDTA tubes from individuals homozygous for HbA (n = 40) and heterozygous for Hb-Tacoma (n = 20). Samples were then immediately analyzed with the Afinion POC instrument. After analysis, aliquots of each sample were frozen at -80 °C. The frozen samples were shipped on dry ice to the European Reference Laboratory for Glycohemoglobin (ERL) and analyzed with three International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) Secondary Reference Measurement Procedures (SRMPs). The Premier Hb9210 was used as the reference method. When compared to the reference method, samples with Hb-Tacoma yielded mean relative differences of 31.8% on the Tosoh G8, 21.5% on the Roche Tina-quant Gen. 2 and 16.8% on the Afinion. The Afinion cannot be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma.

  2. Is insulin the preferred treatment for HbA1c >9%?

    Science.gov (United States)

    Bloomgarden, Zachary

    2017-09-01

    The algorithms and guidelines of the American Association of Clinical Endocrinologists and the American Diabetes Association recommend that insulin administration be strongly considered for people with type 2 diabetes (T2D) with HbA1c levels exceeding 9.0% and 10%, respectively. Although the caveat is given in both sets of recommendations that this is particularly appropriate when patients are "symptomatic," referring to urinary frequency with increased thirst and appetite, weight loss, and ketosis, the clinical definition of such presentations may be ill-defined, and it is noteworthy that both documents consider insulin to offer particular benefit under such circumstances. However, with multiple options for glycemic treatment, it is of interest to reconsider this argument for insulin use. It should be recalled that in the UK Prospective Diabetes Study, diet alone was associated with a reduction in HbA1c from 9% to 7%. Drug-naïve people with T2D do often show surprisingly strong reductions in HbA1c with metformin-based dual-agent oral treatment approaches; a recent report showed that even with baseline HbA1c >11%, the combination of metformin with a sulfonylurea, pioglitazone, or sitagliptin was associated with reduction in HbA1c from 11.6% to 6.0%. A 32-week study of the combination of rosiglitazone with metformin in patients with mean baseline HbA1c 8.9% showed a mean HbA1c reduction of 2.3%, and an open-label cohort with baseline HbA1c 11.8% had a reduction in HbA1c to 7.8%. With metformin plus sitagliptin, a mean placebo-adjusted HbA1c reduction of 2.1% from a baseline of 8.8% was reported, with those patients with baseline HbA1c >9% having a 2.6% reduction in HbA1c, and an open-label cohort with baseline HbA1c 11.2% having a 2.9% reduction in HbA1c. Similar 2% HbA1c reductions from baseline levels of 9.1% were seen with metformin in initial combination with the sodium-glucose cotransporter 2 (SGLT2) inhibitor dapagliflozin. Although such dual oral agent

  3. Comparing facility-level methane emission rate estimates at natural gas gathering and boosting stations

    Directory of Open Access Journals (Sweden)

    Timothy L. Vaughn

    2017-11-01

    Full Text Available Coordinated dual-tracer, aircraft-based, and direct component-level measurements were made at midstream natural gas gathering and boosting stations in the Fayetteville shale (Arkansas, USA. On-site component-level measurements were combined with engineering estimates to generate comprehensive facility-level methane emission rate estimates (“study on-site estimates (SOE” comparable to tracer and aircraft measurements. Combustion slip (unburned fuel entrained in compressor engine exhaust, which was calculated based on 111 recent measurements of representative compressor engines, accounts for an estimated 75% of cumulative SOEs at gathering stations included in comparisons. Measured methane emissions from regenerator vents on glycol dehydrator units were substantially larger than predicted by modelling software; the contribution of dehydrator regenerator vents to the cumulative SOE would increase from 1% to 10% if based on direct measurements. Concurrent measurements at 14 normally-operating facilities show relative agreement between tracer and SOE, but indicate that tracer measurements estimate lower emissions (regression of tracer to SOE = 0.91 (95% CI = 0.83–0.99, R2 = 0.89. Tracer and SOE 95% confidence intervals overlap at 11/14 facilities. Contemporaneous measurements at six facilities suggest that aircraft measurements estimate higher emissions than SOE. Aircraft and study on-site estimate 95% confidence intervals overlap at 3/6 facilities. The average facility level emission rate (FLER estimated by tracer measurements in this study is 17–73% higher than a prior national study by Marchese et al.

  4. Association of fibrinogen with HbA1C in diabetic foot ulcer

    Science.gov (United States)

    Pase, M. A.; Gatot, D.; Lindarto, D.

    2018-03-01

    Fibrinogen is one of the inflammatory markers of vascular changes and endothelial dysfunction in diabetic patients. The aim of this study to associate serum fibrinogen levels with HbA1C in diabetic foot ulcer (DFU). This study was cross-sectional and retrospective in DFU patients from January to July 2017 in Haji Adam Malik Central General Hospital. The patients enrolled in the study were T2DM with DFU as a complication. The grading of DFU was evaluated according to the Wagner’s Classification. Serum fibrinogen level, HbA1C and ankle-brachial index (ABI) were carried out directly in the patients. Fibrinogen serum levels were found significantly with HbA1C (P=0.001, r=0.387) and ABI (P=0.008, r=-0.454). Fibrinogen serum levels in DFU patients were positively correlated with HbA1C and significantly higher in patients with poor glycemic control.

  5. Solids loading evaluation for HB-line scrap recovery filters

    International Nuclear Information System (INIS)

    Crowder, M.L.

    2000-01-01

    The HB-Line Scrap Recovery facility uses wire screen filters to remove solids from plutonium-containing solutions transferred from the slab tank dissolvers. At times, the accumulation of solids is large enough to cause blinding (i.e., pluggage) of the filters. If the solids contain undissolved plutonium, significant accumulation of fissile material could impact operations. To address this potential issue, experiments were performed to define the minimum solids required to completely blind a filter. The solids loading experiments were performed by arranging 25- and 10-microm HB-Line filters in series to simulate the equipment in the scrap recovery process. Separate tests were performed using coarse and fine glass frit and cerium oxide powder suspended in 35 wt% sodium nitrate solution using a small turbine mixer. The solution and solids were transferred from a reservoir through the filter housings by vacuum. In each case, the 25-microm filter blinded first and was full of wet cake. After drying and accounting for the sodium nitrate in the filter cake, the following results were obtained. The results of the solids loading tests demonstrated that at least 800 g of solids accumulated in the filter housing before flow stopped. The actual amount of collected material was dependent upon the physical properties of the solids such as density and particle size. The mass of solids collected by the blinded 25-microm filter increased when successively finer solids were used in the experiments. Based on these results, one should anticipate that filters in the HB-Line Scrap Recovery Facility have the potential to collect similar quantities of material before transfer of solution from the dissolvers is severely impacted

  6. The association between estimated average glucose levels and fasting plasma glucose levels

    Directory of Open Access Journals (Sweden)

    Giray Bozkaya

    2010-01-01

    Full Text Available OBJECTIVE: The level of hemoglobin A1c (HbA1c, also known as glycated hemoglobin, determines how well a patient's blood glucose level has been controlled over the previous 8-12 weeks. HbA1c levels help patients and doctors understand whether a particular diabetes treatment is working and whether adjustments need to be made to the treatment. Because the HbA1c level is a marker of blood glucose for the previous 120 days, average blood glucose levels can be estimated using HbA1c levels. Our aim in the present study was to investigate the relationship between estimated average glucose levels, as calculated by HbA1c levels, and fasting plasma glucose levels. METHODS: The fasting plasma glucose levels of 3891 diabetic patient samples (1497 male, 2394 female were obtained from the laboratory information system used for HbA1c testing by the Department of Internal Medicine at the Izmir Bozyaka Training and Research Hospital in Turkey. These samples were selected from patient samples that had hemoglobin levels between 12 and 16 g/dL. The estimated glucose levels were calculated using the following formula: 28.7 x HbA1c - 46.7. Glucose and HbA1c levels were determined using hexokinase and high performance liquid chromatography (HPLC methods, respectively. RESULTS: A strong positive correlation between fasting plasma glucose levels and estimated average blood glucose levels (r=0.757, p<0.05 was observed. The difference was statistically significant. CONCLUSION: Reporting the estimated average glucose level together with the HbA1c level is believed to assist patients and doctors determine the effectiveness of blood glucose control measures.

  7. HB D Los Angeles in a Brazilian family Hb D Los Angeles em família brasileira

    Directory of Open Access Journals (Sweden)

    Guilherme G. Leoneli

    2001-09-01

    Full Text Available Inherited disorders of hemoglobin, the most common monogenic disease, are now well understood at the molecular level, knowledge, which has led to considerable improvements in their control and management. The Brazilian population is multiethnic, and the correct characterization of the Hb D is important, mainly because the method available for detection of abnormal hemoglobins, present a migration in the same zone at alkaline pH, for Hb S, D, and G for example. In this paper we studied a family with an abnormal hemoglobin like S in alkaline electrophoresis, by appropriated methods including HPLC and molecular analysis, characterized as hemoglobin D Los Angeles.As doenças hereditária da hemoglobina são as mais comuns doenças monogênicas e atualmente bem conhecidas do ponto de vista molecular, fato este que propiciou um avanço no seu controle e manuseio. A população brasileira caracteriza-se pela multiplicidade étnica e a caracterização da Hb D torna-se importante por este dado, associado ao fato de que os métodos de detecção das hemoglobinopatias comumente não identificam esta fração anormal que apresenta a peculiaridade de migração eletroforéticia em pH alcalino na mesma zona observada nas Hb S e G. Neste relato é apresentado um estudo familiar no qual é empregada metodologia adequada, o HLPC, que permite a identificação da Hb D.

  8. Significance of HbA1c and its measurement in the diagnosis of diabetes mellitus: US experience

    Directory of Open Access Journals (Sweden)

    Juarez DT

    2014-10-01

    Full Text Available Deborah Taira Juarez, Kendra M Demaris, Roy Goo, Christina Louise Mnatzaganian, Helen Wong SmithDaniel K Inouye College of Pharmacy, University of Hawaii at Hilo, Honolulu, HI, USAAbstract: The 2014 American Diabetes Association guidelines denote four means of diagnosing diabetes. The first of these is a glycosylated hemoglobin (HbA1c >6.5%. This literature review summarizes studies (n=47 in the USA examining the significance, strengths, and limitations of using HbA1c as a diagnostic tool for diabetes, relative to other available means. Due to the relatively recent adoption of HbA1c as a diabetes mellitus diagnostic tool, a hybrid systematic, truncated review of the literature was implemented. Based on these studies, we conclude that HbA1c screening for diabetes has been found to be convenient and effective in diagnosing diabetes. HbA1c screening is particularly helpful in community-based and acute care settings where tests requiring fasting are not practical. Using HbA1c to diagnose diabetes also has some limitations. For instance, HbA1c testing may underestimate the prevalence of diabetes, particularly among whites. Because this bias differs by racial group, prevalence and resulting estimates of health disparities based on HbA1c screening differ from those based on other methods of diagnosis. In addition, existing evidence suggests that HbA1c screening may not be valid in certain subgroups, such as children, women with gestational diabetes, patients with human immunodeficiency virus, and those with prediabetes. Further guidelines are needed to clarify the appropriate use of HbA1c screening in these populations.Keywords: diabetes mellitus, diagnosis, glycosylated hemoglobin, USA

  9. A two-step screening, measurement of HbA1c in association with FPG, may be useful in predicting diabetes.

    Directory of Open Access Journals (Sweden)

    Kyoko Nomura

    Full Text Available BACKGROUNDS: We compared the usefulness of fasting plasma glucose (FPG, or hemoglobin A1c (HbA1c, or both in predicting type 2 diabetes. METHODS: This retrospective cohort study investigated 9,322 Japanese adults (4,786 men and 4,536 women, aged 19-69 yrs, free of diabetes at baseline. Usefulness was assessed by predictive values (PV, sensitivity, specificity, and the area under the receiver operating characteristic curve (AUROC maximised under the best cut-off point. RESULTS: During the average 6 years of follow-up, 221 men (4.6% and 92 women (2% developed diabetes. The best cut-off points for FPG (i.e., 5.67 mmol/l for men and 5.5 mmol/l for women gave excellent AUROC, and the highest positive PV (13% for men and 9% for women in predicting diabetes. In high risk subjects with FPG 6.1-6.9 mmol/l, 119 men (26.8% and 39 women (28.3% developed diabetes. Under the best cut-off points of FPG 6.39 mmol/l and A1c 5.8, AUROC and positive PV for FPG slightly decreased indicating FPG became less useful and were statistically indistinguishable from those for HbA1c in men. In fact, HbA1c was the most useful in women: HbA1c of 6.0% gave the highest positive likelihood ratio of 2.74 and larger AUROC than did FPG. Although AUROC for HbA1c was acceptable and indistinguishable from that for the combined use, HbA1c had higher specificity and positive LR than did the combined use. CONCLUSIONS: This study demonstrated that FPG was the most useful to predict diabetes in the general population. However, in subjects with FPG 6.1-6.9 mmol/l, FPG became less useful and diagnostic performance of FPG was indistinguishable from that of HbA1c in men whereas HbA1c was the most useful in women. Thus, a two-step screening, measurement of HbA1c in association with FPG, may be useful in predicting diabetes.

  10. Analytical verification and quality assessment of the Tosoh HLC-723GX HbA1c analyzer

    Directory of Open Access Journals (Sweden)

    Marko Ris

    2017-04-01

    Full Text Available Objectives: Ion-exchange high-performance liquid chromatography (IE-HPLC has long been used as a reproducible and versatile analytical tool for HbA1c measurement.In this study, we performed analytical verification and quality assessment of the recently introduced small IE-HPLC Tosoh HLC-723GX HbA1c analyzer, and a comparison of results to immunoassay (IA and capillary electrophoresis (CE. Design and methods: The total imprecision of Tosoh HLC-723GX was verified according to CLSI EP15-A2 protocol using commercial control materials (C-QC and pooled human whole blood samples (HWB. The Sigma metric was used for the evaluation of quality targets. HbA1c results were compared to automated CE (MiniCap Flex Piercing, Sebia, France and IA (Tina-quant HbA1c Gen 2, Cobas Integra 400+, Roche Diagnostics, USA procedures. Results: The total imprecision of Tosoh HLC-723GX-HbA1c for IFCC(mmol/mol and NGSP(% units was: 1.91/1.25% (HbA1c=31 mmol/mol/5.0% and 0.51/0.63% (HbA1c=84 mmol/mol/9.8% for C-QC, and 0.39/0.2% (HbA1c=47 mmol/mol/6.5% and 0.77/0.46% (HbA1c=94 mmol/mol/10.8% in HWB samples, respectively. Bland-Altman analysis did not reveal any deviation of the results between Tosoh HLC-723GX and CE: mean difference 0.0% (95%CI: −0.02927 to 0.02653%, while the mean HbA1c difference against IA was −0.07% (95%CI: −0.1039 to −0.02765. At the selected HbA1c clinical decision level (48 mmol/mol/6,5%, six sigma analysis gave σ value of 3.91, within a desirable classification of performance. Conclusion: The analytical performance of the Tosoh HLC-723GX complies with the rigorous quality criteria for clinical use of HbA1c, with the results comparable to the CE procedure. Tosoh HLC-723GX provides a plausible analytical choice for reliable HbA1c measurement in low-volume laboratories. Keywords: HbA1c, Quality targets, Six sigma, Tosoh HLC-723GX analyzer

  11. A Mosaic Expression of a Hb J-Amiens (HBB: c.54G > T; p.Lys18Asn) and its Interference with Hb A1c Analysis.

    Science.gov (United States)

    Schiemsky, Toon; Van Hoovels, Lieve; Desmet, Koen J O; Phylipsen, Marion; Harteveld, Cornelis L; Kieffer, Davy M J

    2015-01-01

    We report the case of a 56-year-old Caucasian woman in whom hemoglobinopathy screening was triggered following an aberrant Hb A1c analysis. Preliminary diagnosis of the hemoglobin (Hb) variant was obtained through cation exchange high performance liquid chromatography (HPLC) and gel electrophoresis. DNA analysis confirmed the presence of Hb J-Amiens [β17(A14)Lys→Asn; HBB: c.[54G > C or 54G > T)]. However, an unbalanced ratio between wild type and mutant signal after direct sequencing and a lower than expected percentage of this Hb variant led to the suggestion of a mosaic expression. Furthermore, different methods [capillary zone electrophoresis (CZE), cation exchange HPLC and boronate affinity] were tested to study the possible interference of this variant with Hb A1c measurements. These investigations showed a clinically relevant difference between the methods tested. Hb A1c analysis may lead to the discovery of new Hb variants or mosaicism for previously described Hb variants. This may have genetic consequences for the offspring of carriers and brings about the question of partner testing.

  12. E AREA LOW LEVEL WASTE FACILITY DOE 435.1 PERFORMANCE ASSESSMENT

    Energy Technology Data Exchange (ETDEWEB)

    Wilhite, E

    2008-03-31

    This Performance Assessment for the Savannah River Site E-Area Low-Level Waste Facility was prepared to meet requirements of Chapter IV of the Department of Energy Order 435.1-1. The Order specifies that a Performance Assessment should provide reasonable assurance that a low-level waste disposal facility will comply with the performance objectives of the Order. The Order also requires assessments of impacts to water resources and to hypothetical inadvertent intruders for purposes of establishing limits on radionuclides that may be disposed near-surface. According to the Order, calculations of potential doses and releases from the facility should address a 1,000-year period after facility closure. The point of compliance for the performance measures relevant to the all pathways and air pathway performance objective, as well as to the impact on water resources assessment requirement, must correspond to the point of highest projected dose or concentration beyond a 100-m buffer zone surrounding the disposed waste following the assumed end of active institutional controls 100 years after facility closure. During the operational and institutional control periods, the point of compliance for the all pathways and air pathway performance measures is the SRS boundary. However, for the water resources impact assessment, the point of compliance remains the point of highest projected dose or concentration beyond a 100-m buffer zone surrounding the disposed waste during the operational and institutional control periods. For performance measures relevant to radon and inadvertent intruders, the points of compliance are the disposal facility surface for all time periods and the disposal facility after the assumed loss of active institutional controls 100 years after facility closure, respectively. The E-Area Low-Level Waste Facility is located in the central region of the SRS known as the General Separations Area. It is an elbow-shaped, cleared area, which curves to the northwest

  13. Hemoglobin Constant Spring (Hb CS) Missed by HPLC in an Hb E Trait Pregnancy Resulting in Hb H-CS Disease in a Thai Girl: Utility of Capillary Electrophoresis.

    Science.gov (United States)

    Pornprasert, Sakorn; Saoboontan, Supansa; Wiengkum, Thanatcha

    2016-06-01

    Hemoglobin Constant Spring [Hb CS; α142, Term→Gln (TAA>CAA IN α2)] is often missed by routine laboratory testing, especially in subjects with co-inheritance of β-thalassemia or β-variants. We reported the case of a 1-year-old female with Hb H-CS disease who was born from a father with heterozygous of α-thalassemia-1 Southeast Asian type deletion and a mother with the combination of Hb CS and Hb E [β26 (B8) Glu→Lys, GAG>AAG] trait. A very tiny peak of Hb CS of the mother was easily ignored on the high performance liquid chromatography chromatogram while it was clearly seen on the capillary electrophoresis (CE) electrophoregram. Therefore, the CE is useful in screening for heterozygous Hb CS in a person with Hb E trait. This is of potential benefit for prevention of new cases of Hb H-CS disease.

  14. Baseline HbA1c to Identify High-Risk Gestational Diabetes: Utility in Early vs Standard Gestational Diabetes.

    Science.gov (United States)

    Sweeting, Arianne N; Ross, Glynis P; Hyett, Jon; Molyneaux, Lynda; Tan, Kris; Constantino, Maria; Harding, Anna Jane; Wong, Jencia

    2017-01-01

    The increasing prevalence of gestational diabetes mellitus (GDM) necessitates risk stratification directing limited antenatal resources to those at greatest risk. Recent evidence demonstrates that an early pregnancy glycated hemoglobin (HbA1c ≥5.9% (41 mmol/mol) predicts adverse pregnancy outcomes. To determine the optimal HbA1c threshold for adverse pregnancy outcomes in GDM in a treated multiethnic cohort and whether this differs in women diagnosed HbA1c (single-laboratory) measurement at the time of GDM diagnosis. Maternal clinical and pregnancy outcome data were collected prospectively. The association between baseline HbA1c and adverse pregnancy outcomes in early vs standard GDM. HbA1c was measured at a median of 17.6 ± 3.3 weeks' gestation in early GDM (n = 844) and 29.4 ± 2.6 weeks' gestation in standard GDM (n = 2254). In standard GDM, HbA1c >5.9% (41 mmol/mol) was associated with the greatest risk of large-for-gestational-age (odds ratio [95% confidence interval] = 2.7 [1.5-4.9]), macrosomia (3.5 [1.4-8.6]), cesarean section (3.6 [2.1-6.2]), and hypertensive disorders (2.6 [1.1-5.8]). In early GDM, similar HbA1c associations were seen; however, lower HbA1c correlated with the greatest risk of small-for-gestational-age (P trend = 0.004) and prevalence of neonatal hypoglycemia. Baseline HbA1c >5.9% (41 mmol/mol) identifies an increased risk of large-for-gestational-age, macrosomia, cesarean section, and hypertensive disorders in standard GDM. Although similar associations are seen in early GDM, higher HbA1c levels do not adequately capture risk-limiting utility as a triage tool in this cohort. Copyright © 2017 by the Endocrine Society

  15. Hemoglobin A1c (HbA1c) changes over time among adolescent and young adult participants in the T1D exchange clinic registry.

    Science.gov (United States)

    Clements, Mark A; Foster, Nicole C; Maahs, David M; Schatz, Desmond A; Olson, Beth A; Tsalikian, Eva; Lee, Joyce M; Burt-Solorzano, Christine M; Tamborlane, William V; Chen, Vincent; Miller, Kellee M; Beck, Roy W

    2016-08-01

    Hemoglobin A1c (HbA1c) levels among individuals with type 1 diabetes (T1D) influence the longitudinal risk for diabetes-related complications. Few studies have examined HbA1c trends across time in children, adolescents, and young adults with T1D. This study examines changes in glycemic control across the specific transition periods of pre-adolescence-to-adolescence and adolescence-to-young adulthood, and the demographic and clinical factors associated with these changes. Available HbA1c lab results for up to 10 yr were collected from medical records at 67 T1D Exchange clinics. Two retrospective cohorts were evaluated: the pre-adolescent-to-adolescent cohort consisting of 85 016 HbA1c measurements from 6574 participants collected when the participants were 8-18 yr old and the adolescent-to-young adult cohort, 2200 participants who were 16-26 yr old at the time of 17 279 HbA1c measurements. HbA1c in the 8-18 cohort increased over time after age 10 yr until ages 16-17; followed by a plateau. HbA1c levels in the 16-26 cohort remained steady from 16-18, and then gradually declined. For both cohorts, race/ethnicity, income, health insurance, and pump use were all significant in explaining individual variations in age-centered HbA1c (p HbA1c trajectory. Glycemic control among patients 8-18 yr old worsens over time, through age 16. Elevated HbA1c levels observed in 18 yr-olds begin a steady improvement into early adulthood. Focused interventions to prevent deterioration in glucose control in pre-adolescence, adolescence, and early adulthood are needed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Role of HbA1c in predicting risk for congenital malformations.

    Science.gov (United States)

    Hammouda, Sahar Ali Ibrahim; Hakeem, Rubina

    2015-12-01

    Association between conventionally identified hyperglycemias and rates of congenital abnormalities is known; however there is less information about role of HbA1c in determining gestational hyperglycemias and associated risks. This study tried to explore the association between HbA1c in women without known diabetes at first antenatal visit and risk of congenital malformations (CM) among Saudi women living at Al-Madinah Al-Monawarah. Eleven hundred and eighty (1180), healthy, first-trimester pregnant Saudi females without known diabetes, were selected from various antenatal care clinics of Al-Madinah Al-Monawarah city. General clinical and biochemical data was collected for this study by researchers at first visit and the time of delivery. Nearly one fifth (19.6%) of mothers had above normal HbA1c (>5.7) at first visit. Rates of CM had significant positive association with level of HbA1c. Rate of CM among those who had HbA1c in diabetes range, pre-diabetes range or normal range was 27.8%, 9.8% and 3.0%, respectively. The difference was significant between normal and pre-diabetes at the level P=0.000 and between pre-diabetes and diabetes at level P=0.038. In this study HbA1c is found to be a valuable predictor of risk of congenital malformations. This observation calls for further studies and establishment of policies for care of pregnant mothers having higher than normal HbA1c at first visit. Copyright © 2015 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  17. Associations of HbA1c and educational level with risk of cardiovascular events in 32,871 drug-treated patients with Type 2 diabetes: a cohort study in primary care.

    Science.gov (United States)

    Östgren, C J; Sundström, J; Svennblad, B; Lohm, L; Nilsson, P M; Johansson, G

    2013-05-01

    To explore the association of HbA1c and educational level with risk of cardiovascular events and mortality in patients with Type 2 diabetes. A cohort of 32 871 patients with Type 2 diabetes aged 35 years and older identified by extracting data from electronic patient records for all patients who had a diagnosis of Type 2 diabetes and had glucose-lowering agents prescribed between 1999 and 2009 at 84 primary care centres in Sweden. Associations of mean HbA1c levels and educational level with risks of cardiovascular events and all-cause mortality were analysed. The associations of HbA1c with risk of all-cause and cardiovascular mortality were J-shaped, with the lowest risk observed for cardiovascular mortality at an HbA1c level of 51 mmol/mol (6.8%) for subjects on oral agents and 56 mmol/mol (7.3%) in insulin-treated patients. The lowest risk observed for all-cause mortality was at an HbA1c level of 51 mmol/mol (6.8%) for subjects on oral agents and 56 mmol/mol (7.3%) in insulin-treated patients. There was an increased risk for cardiovascular death [hazard ratio 1.6 (1.2-2.1), P = 0.0008] at the lowest HbA1c decile for subjects in the low education category. For subjects with higher education there was no evident J curve for cardiovascular death [hazard ratio 1.2 (0.8-1.6), P = 0.3873]. Our results lend support to the recent American Diabetes Association/ European Association for the Study of Diabetes position statement that emphasizes the importance of additional factors, including the propensity for hypoglycaemia, which should influence HbA1c targets and treatment choices for individual patients. (Clinical Trials Registry No; NCT 01121315). © 2013 The Authors. Diabetic Medicine © 2013 Diabetes UK.

  18. Incidence of hemoglobinopathies and thalassemias in Northern Alberta. Establishment of reference intervals for HbF and HbA2.

    Science.gov (United States)

    Rodriguez-Capote, Karina; Higgins, Trefor N

    2015-07-01

    The aims of this study were to identify the incidence of hemoglobinopathies and thalassemias in Northern Alberta and calculate the reference intervals (RI) for hemoglobin (Hb) HbF and HbA2. A retrospective ad-hoc analysis of the structural Hb variants and thalassemias identified on patients who had a hemoglobinopathy/thalassemia investigation performed between February 1 to December 31, 2013. Results were extracted from the Laboratory Information System. Statistical analysis was performed using MedCalc® version 11.4.2.0 for Windows software. 6616 hemoglobinopathy/thalassemia investigations and HbS screens were physician requested and 602 Hb variants were fortuitously found during HbA1c analysis. 3438 were interpreted as "normal" and 532 were classified as iron deficient. 3306 individuals, with age ranging from 3 to 92 years were included in the RI calculation. HbA2 RI was 2.3% to 3.4% and HbF 0.0% to 1.8%. 524 and 423 α and β thalassemia traits respectively were identified. Additionally ten δβ thalassemia traits and twelve cases of HbH disease were identified. Regarding hemoglobinopathies, 7% were classified as α-chain variants and 93% as β-chain variants with HbS (46%), HbE (16%), HbD Punjab (8%) and HbC (7%) traits being the most prevalent. We also documented 20 homozygous hemoglobinopathies and 36 compound/double heterozygous hemoglobinopathies. A wide diversity of hemoglobinopathies is found in the Northern Alberta population, 80% of the hemoglobinopathies were found as a reflex to HbA1c testing. Reference intervals for HbF and HbA2 were established. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Detection of compound heterozygous of hb constant spring and hb q-Thailand by capillary electrophoresis and high performance liquid chromatography.

    Science.gov (United States)

    Pornprasert, Sakorn; Punyamung, Manoo

    2015-06-01

    A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and HPLC for the detection of Hb CS in samples with compound heterozygous of Hb CS and Hb Q-Thailand. Hemoglobin analysis was performed in blood samples of 2 patients with compound heterozygous of Hb CS and Hb Q-Thailand by using HPLC and CE. The HPLC chromatogram and CE electrophoregram of the two techniques were compared. Hb CS was not found on HPLC chromatogram while Hb QA2 (α2 (QT)δ2), a derivative of Hb Q-Thailand, was presented at the retention time of 4.70-4.80 min and it was close to the retention time of Hb CS. On CE electrophoregram, Hb CS was presented at zone 2 (Z2) and it was distinctly separated from Hb QA2 which was presented at Z1. Therefore, CE was more efficient to the HPLC for diagnosis of compound heterozygous of Hb CS and Hb Q-Thailand.

  20. HB Puerta del Sol [HBA1:c.148A>C], HB Valdecilla [HBA2:c.3G>T], HB Gran Vía [HBA2:c.98T>G], HB Macarena [HBA2:c.358C>T] and HB El Retiro [HBA2:c.364_366dupGTG]: description of five new hemoglobinopathies.

    Science.gov (United States)

    de la Fuente-Gonzalo, Félix; Nieto, Jorge M; Velasco, Diego; Cela, Elena; Pérez, Germán; Fernández-Teijeiro, Ana; Escudero, Antonio; Villegas, Ana; González-Fernández, Fernando A; Ropero, Paloma

    2016-04-01

    Structural hemoglobinopathies do not usually have a clinical impact, but they can interfere with the analytical determination of some parameters, such as the glycated hemoglobin in diabetic patients. Thalassemias represent a serious health problem in areas where their incidence is high. The defects in the post-translational modifications produce hyper-unstable hemoglobin that is not detected by most of electrophoretic or chromatographic methods that are available so far. We studied seven patients who belong to six unrelated families. The first two families were studied because they had peak abnormal hemoglobin (Hb) during routine analytical assays. The other four families were studied because they had microcytosis and hypochromia with normal HbA2 and HbF without iron deficiency. HbA2 and F quantification and abnormal Hb separation were performed by chromatographic and electrophoretic methods. The molecular characterization was performed using specific sequencing. The Hb Puerta del Sol presents electrophoretic mobility and elution in HPLC that is different from HbA and similar to HbS. The electrophoretic and chromatographic profiles of the four other variants are normal and do not show any anomalies, and their identification was only possible with sequencing. Some variants, such as Hb Valdecilla, Hb Gran Vía, Hb Macarena and Hb El Retiro, have significant clinical impact when they are associated with other forms of α-thalassemia, which could lead to more serious forms of this group of pathologies as for HbH disease. Therefore, it is important to maintain an adequate program for screening these diseases in countries where the prevalence is high to prevent the occurrence of severe forms.

  1. Environmental assessment operation of the HB-Line facility and frame waste recovery process for production of Pu-238 oxide at the Savannah River Site

    International Nuclear Information System (INIS)

    1995-04-01

    The Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0948, addressing future operations of the HB-Line facility and the Frame Waste Recovery process at the Savannah River Site (SRS), near Aiken, South Carolina. Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, DOE has concluded that, the preparation of an environmental impact statement is not required, and is issuing this Finding of No Significant Impact

  2. Glutathione Redox System in β-Thalassemia/Hb E Patients

    Directory of Open Access Journals (Sweden)

    Ruchaneekorn W. Kalpravidh

    2013-01-01

    Full Text Available β-thalassemia/Hb E is known to cause oxidative stress induced by iron overload. The glutathione system is the major endogenous antioxidant that protects animal cells from oxidative damage. This study aimed to determine the effect of disease state and splenectomy on redox status expressed by whole blood glutathione (GSH/glutathione disulfide (GSSG and also to evaluate glutathione-related responses to oxidation in β-thalassemia/Hb E patients. Twenty-seven normal subjects and 25 β-thalassemia/Hb E patients were recruited and blood was collected. The GSH/GSSG ratio, activities of glutathione-related enzymes, hematological parameters, and serum ferritin levels were determined in individuals. Patients had high iron-induced oxidative stress, shown as significantly increased serum ferritin, a decreased GSH/GSSG ratio, and increased activities of glutathione-related enzymes. Splenectomy increased serum ferritin levels and decreased GSH levels concomitant with unchanged glutathione-related enzyme activities. The redox ratio had a positive correlation with hemoglobin levels and negative correlation with levels of serum ferritin. The glutathione system may be the body’s first-line defense used against oxidative stress and to maintain redox homeostasis in thalassemic patients based on the significant correlations between the GSH/GSSH ratio and degree of anemia or body iron stores.

  3. HbA1c in relation to incident diabetes and diabetes-related complications in non-diabetic adults at baseline.

    Science.gov (United States)

    Metcalf, Patricia Anne; Kyle, Cam; Kenealy, Tim; Jackson, Rod T

    2017-05-01

    We compared the utility of glycated hemoglobin (HbA 1c ) and oral glucose tolerance (oGTT) in non-diabetic patients for identifying incident diabetes; all-cause mortality; cardiovascular disease (CVD) mortality; CVD, coronary heart disease (CHD), and ischemic stroke events; and diabetes microvascular complications. Data from a New Zealand community setting were prospectively linked to hospitalization, mortality, pharmaceutical and laboratory test results data. After applying exclusion criteria (prior laboratory diagnosis or history of drug treatment for diabetes or hospitalization for diabetes or CVD event), there were 31,148 adults who had an HbA 1c and 2-h 75g oGTT. HbA 1c was measured by ion-exchange high-performance liquid chromatography, and glucose using a commercial enzymatic method. We compared glycemic measures and outcomes using multivariable Cox proportional hazards regression. The median follow-up time was 4years (range 0 to 13). The mean age was 57·6years and 53·0% were male. After adjusting for other glycemic measures (fasting glucose, 2-h glucose and/or HbA 1c where relevant) in addition to age, sex, ethnicity and smoking habit, the hazard ratios for incident diabetes and diabetes complications of retinopathy and nephropathy were highest for 2-h glucose levels, followed by HbA 1c and lastly by fasting glucose. However, all-cause mortality and CHD were significantly associated with HbA 1c concentrations only, and ischemic stroke and CVD events with 2-h glucose only. Circulatory complications showed a stronger association with HbA 1c . Apart from neuropathy, HbA 1c showed stronger associations with outcomes compared to fasting glucose and provides a convenient alternative to an oGTT. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Impact of Mean Cell Hemoglobin on Hb A1c-Defined Glycemia Status.

    Science.gov (United States)

    Rodriguez-Segade, Santiago; Garcia, Javier Rodriguez; García-López, José M; Gude, Francisco; Casanueva, Felipe F; Rs-Alonso, Santiago; Camiña, Félix

    2016-12-01

    Several hematological alterations are associated with altered hemoglobin A 1c (Hb A 1c ). However, there have been no reports of their influence on the rates of exceeding standard Hb A 1c thresholds by patients for whom Hb A 1c determination is requested in clinical practice. The initial data set included the first profiles (complete blood counts, Hb A 1c , fasting glucose, and renal and hepatic parameters) of all adult patients for whom such a profile was requested between 2008 and 2013 inclusive. After appropriate exclusions, 21844 patients remained in the study. Linear and logistic regression models were adjusted for demographic, hematological, and biochemical variables excluded from the predictors. Mean corpuscular hemoglobin (MCH) and mean corpuscular volume (MCV) correlated negatively with Hb A 1c . Fasting glucose, MCH, and age emerged as predictors of Hb A 1c in a stepwise regression that discarded sex, hemoglobin, MCV, mean corpuscular hemoglobin concentration (MCHC), serum creatinine, and liver disease. Mean Hb A 1c in MCH interdecile intervals fell from 6.8% (51 mmol/mol) in the lowest (≤27.5 pg) to 6.0% (43 mmol/mol) in the highest (>32.5 pg), with similar results for MCV. After adjustment for fasting glucose and other correlates of Hb A 1c , a 1 pg increase in MCH reduced the odds of Hb A 1c -defined dysglycemia, diabetes and poor glycemia control by 10%-14%. For at least 25% of patients, low or high MCH or MCV levels are associated with increased risk of an erroneous Hb A 1c -based identification of glycemia status. Although causality has not been demonstrated, these parameters should be taken into account in interpreting Hb A 1c levels in clinical practice. © 2016 American Association for Clinical Chemistry.

  5. Structured education using Dose Adjustment for Normal Eating (DAFNE) reduces long-term HbA1c and HbA1c variability.

    Science.gov (United States)

    Walker, G S; Chen, J Y; Hopkinson, H; Sainsbury, C A R; Jones, G C

    2018-06-01

    Previous evidence has demonstrated that participation in the Dose Adjustment for Normal Eating (DAFNE) education programme can reduce HbA 1c and severe hypoglycaemia in people with Type 1 diabetes. In a number of studies, increased HbA 1c variability has been associated with higher diabetic morbidity and mortality. No studies have examined the impact of structured education on HbA 1c variability in Type 1 diabetes. People with Type 1 diabetes who had attended DAFNE were identified for inclusion from the Scottish Care Information-Diabetes dataset. HbA 1c median and variability, expressed as coefficient of variation (CV) before and after DAFNE was calculated. Some 1061 individuals participated in DAFNE education and 687 met the inclusion criteria. A significant median reduction in HbA 1c [-3.5 mmol/mol (-0.3%)] was seen at 12 months with a significant reduction [-1.5 mmol/mol (-0.1%)] still seen at 60 months of follow-up. HbA 1c variability as measured by CV was significantly lower during the post-DAFNE period: 0.08 (IQR 0.05-0.12) reduced to 0.07 (IQR 0.05-0.10); P = 0.002. The data confirm that DAFNE participation improves glycaemic control in Type 1 diabetes with benefits being sustained for 5 years. This study is the first to demonstrate reduced HbA 1c variability after completion of structured education. This is new evidence of the beneficial impact of DAFNE on glycaemic profile. © 2018 Diabetes UK.

  6. Correlation of same-visit HbA1c test with laboratory-based measurements: A MetroNet study

    Directory of Open Access Journals (Sweden)

    West Patricia A

    2005-07-01

    Full Text Available Abstract Background Glycated hemoglobin (HbA1c results vary by analytical method. Use of same-visit HbA1c testing methodology holds the promise of more efficient patient care, and improved diabetes management. Our objective was to test the feasibility of introducing a same-visit HbA1c methodology into busy family practice centers (FPC and to calculate the correlation between the same-visit HbA1c test and the laboratory method that the clinical site was currently using for HbA1c testing. Methods Consecutive diabetic patients 18 years of age and older having blood samples drawn for routine laboratory analysis of HbA1c were asked to provide a capillary blood sample for same-visit testing with the BIO-RAD Micromat II. We compared the results of the same-visit test to three different laboratory methods (one FPC used two different laboratories. Results 147 paired samples were available for analysis (73 from one FPC; 74 from the other. The Pearson correlation of Micromat II and ion-exchange HPLC was 0.713 (p Conclusion For each of the laboratory methods, the correlation coefficient was lower than the 0.96 reported by the manufacturer. This might be due to variability introduced by the multiple users of the Micromat II machine. The mean HbA1c results were also consistently lower than those obtained from laboratory analysis. Additionally, the amount of dedicated time required to perform the assay may limit its usefulness in a busy clinical practice. Before introducing a same-visit HbA1c methodology, clinicians should compare the rapid results to their current method of analysis.

  7. Aperture area measurement facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has established an absolute aperture area measurement facility for circular and near-circular apertures use in radiometric instruments. The facility consists of...

  8. Source Terms for HFIR Beam Tube Shielding Analyses, and a Complete Shielding Analysis of the HB-3 Tube

    International Nuclear Information System (INIS)

    Bucholz, J.A.

    2000-01-01

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory is in the midst of a massive upgrade program to enhance experimental facilities. The reactor presently has four horizontal experimental beam tubes, all of which will be replaced or redesigned. The HB-2 beam tube will be enlarged to support more guide tubes, while the HB-4 beam tube will soon include a cold neutron source

  9. Source Terms for HFIR Beam Tube Shielding Analyses, and a Complete Shielding Analysis of the HB-3 Tube

    Energy Technology Data Exchange (ETDEWEB)

    Bucholz, J.A.

    2000-07-01

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory is in the midst of a massive upgrade program to enhance experimental facilities. The reactor presently has four horizontal experimental beam tubes, all of which will be replaced or redesigned. The HB-2 beam tube will be enlarged to support more guide tubes, while the HB-4 beam tube will soon include a cold neutron source.

  10. Facilities projects performance measurement system

    International Nuclear Information System (INIS)

    Erben, J.F.

    1979-01-01

    The two DOE-owned facilities at Hanford, the Fuels and Materials Examination Facility (FMEF), and the Fusion Materials Irradiation Test Facility (FMIT), are described. The performance measurement systems used at these two facilities are next described

  11. The isolation of the γ subunit of fetal hemoglobin (HbF) and its use in a radioimmunoassay for HbF

    International Nuclear Information System (INIS)

    James, R.F.L.; Shuster, J.; Freedman, S.O.; Gold, P.

    1980-01-01

    A method is described for the purification, from fetal hemoglobin (HbF), of the fetal specific globin chain (γ chain) in its native state. In the absence of α chain (the globin chain common to all adult human hemoglobins) γ chain, when used as an immunogen, is able to express its unique antigenicity. Here, a specific, high titer antiserum raised against γ chain has been used to establish a sensitive radioimmunoassay for HbF. This approach may be applicable to the measurement of other normal and abnormal hemoglobins. (Auth.)

  12. Energy balance and macronutrient distribution in relation to C-reactive protein and HbA1c levels among patients with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Hiba Bawadi

    2016-05-01

    Full Text Available Background: Recently growing evidence indicates that obesity and diabetes are states of inflammation associated with elevated circulation of inflammatory mediators. Excess adiposity and oxidative stress, induced by feeding, may also lead to a state of low-grade inflammation. Objective: This study aimed at investigating energy balance and distribution in relation to low-grade inflammation among patients with type 2 diabetes. Design: A cross-sectional study included 198 male and female patients with type 2 diabetes. Patients’ weight, height, waist circumference, total body fat and truncal fat percent, energy, and macronutrient intake were measured. Venous blood specimens were collected, and levels of HbA1c and serum levels of high-sensitivity C-reactive protein (hs-CRP were determined. Results: After adjusting for covariates (body mass index, total body fat, and truncal fat, energy balance was positively correlated with hs-CRP and HbA1c. A positive energy balance was also associated with increased waist circumference and truncal fat percent (p<0.05. Total energy intake, percent energy from fat (p=0.04, and percent energy from proteins (p=0.03, but not percent energy from carbohydrates (p=0.12, were also correlated with higher hs-CRP levels among poorly glycemic-controlled patients. Conclusion: Positive energy balance is associated with elevations in hs-CRP. Increased energy intake and increased percentages of energy from fat and protein are associated with elevated hs-CRP among patients with poor glycemic control.

  13. Periodontal inflamed surface area and C-reactive protein as predictors of HbA1c: a study in Indonesia.

    Science.gov (United States)

    Susanto, Hendri; Nesse, Willem; Dijkstra, Pieter U; Hoedemaker, Evelien; van Reenen, Yvonne Huijser; Agustina, Dewi; Vissink, Arjan; Abbas, Frank

    2012-08-01

    Periodontitis may exert an infectious and inflammatory burden, evidenced by increased C-reactive protein (CRP). This burden may impair blood glucose control (HbA1c). The aim of our study was to analyze whether periodontitis severity as measured with the periodontal inflamed surface area (PISA) and CRP predict HbA1c levels in a group of healthy Indonesians and a group of Indonesians treated for type 2 diabetes mellitus (DM2). A full-mouth periodontal examination, including probing pocket depth, gingival recession, clinical attachment loss, plaque index and bleeding on probing, was performed in 132 healthy Indonesians and 101 Indonesians treated for DM2. Using these data, PISA was calculated. In addition, HbA1c and CRP were analyzed. A validated questionnaire was used to assess smoking, body mass index (BMI), education and medical conditions. In regression analyses, it was assessed whether periodontitis severity and CRP predict HbA1c, controlling for confounding and effect modification (i.e., age, sex, BMI, pack years, and education). In healthy Indonesians, PISA and CRP predicted HbA1c as did age, sex, and smoking. In Indonesians treated for DM2, PISA did not predict HbA1c. Periodontitis may impair blood glucose regulation in healthy Indonesians in conjunction with elevated CRP levels. The potential effect of periodontitis on glucose control in DM2 patients may be masked by DM2 treatment. periodontitis may impair blood glucose control through exerting an inflammatory and infectious burden evidenced by increased levels of CRP.

  14. Low-level radioactive waste disposal facility closure

    International Nuclear Information System (INIS)

    White, G.J.; Ferns, T.W.; Otis, M.D.; Marts, S.T.; DeHaan, M.S.; Schwaller, R.G.; White, G.J.

    1990-11-01

    Part I of this report describes and evaluates potential impacts associated with changes in environmental conditions on a low-level radioactive waste disposal site over a long period of time. Ecological processes are discussed and baselines are established consistent with their potential for causing a significant impact to low-level radioactive waste facility. A variety of factors that might disrupt or act on long-term predictions are evaluated including biological, chemical, and physical phenomena of both natural and anthropogenic origin. These factors are then applied to six existing, yet very different, low-level radioactive waste sites. A summary and recommendations for future site characterization and monitoring activities is given for application to potential and existing sites. Part II of this report contains guidance on the design and implementation of a performance monitoring program for low-level radioactive waste disposal facilities. A monitoring programs is described that will assess whether engineered barriers surrounding the waste are effectively isolating the waste and will continue to isolate the waste by remaining structurally stable. Monitoring techniques and instruments are discussed relative to their ability to measure (a) parameters directly related to water movement though engineered barriers, (b) parameters directly related to the structural stability of engineered barriers, and (c) parameters that characterize external or internal conditions that may cause physical changes leading to enhanced water movement or compromises in stability. Data interpretation leading to decisions concerning facility closure is discussed. 120 refs., 12 figs., 17 tabs

  15. Low-level radioactive waste disposal facility closure

    Energy Technology Data Exchange (ETDEWEB)

    White, G.J.; Ferns, T.W.; Otis, M.D.; Marts, S.T.; DeHaan, M.S.; Schwaller, R.G.; White, G.J. (EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1990-11-01

    Part I of this report describes and evaluates potential impacts associated with changes in environmental conditions on a low-level radioactive waste disposal site over a long period of time. Ecological processes are discussed and baselines are established consistent with their potential for causing a significant impact to low-level radioactive waste facility. A variety of factors that might disrupt or act on long-term predictions are evaluated including biological, chemical, and physical phenomena of both natural and anthropogenic origin. These factors are then applied to six existing, yet very different, low-level radioactive waste sites. A summary and recommendations for future site characterization and monitoring activities is given for application to potential and existing sites. Part II of this report contains guidance on the design and implementation of a performance monitoring program for low-level radioactive waste disposal facilities. A monitoring programs is described that will assess whether engineered barriers surrounding the waste are effectively isolating the waste and will continue to isolate the waste by remaining structurally stable. Monitoring techniques and instruments are discussed relative to their ability to measure (a) parameters directly related to water movement though engineered barriers, (b) parameters directly related to the structural stability of engineered barriers, and (c) parameters that characterize external or internal conditions that may cause physical changes leading to enhanced water movement or compromises in stability. Data interpretation leading to decisions concerning facility closure is discussed. 120 refs., 12 figs., 17 tabs.

  16. Dynamics of α-Hb chain binding to its chaperone AHSP depends on heme coordination and redox state.

    Science.gov (United States)

    Kiger, Laurent; Vasseur, Corinne; Domingues-Hamdi, Elisa; Truan, Gilles; Marden, Michael C; Baudin-Creuza, Véronique

    2014-01-01

    AHSP is an erythroid molecular chaperone of the α-hemoglobin chains (α-Hb). Upon AHSP binding, native ferric α-Hb undergoes an unprecedented structural rearrangement at the heme site giving rise to a 6th coordination bond with His(E7). Recombinant AHSP, WT α-Hb:AHSP and α-Hb(HE7Q):AHSP complexes were expressed in Escherichia coli. Thermal denaturation curves were measured by circular dichroism for the isolated α-Hb and bound to AHSP. Kinetics of ligand binding and redox reactions of α-Hb bound to AHSP as well as α-Hb release from the α-Hb:AHSP complex were measured by time-resolved absorption spectroscopy. AHSP binding to α-Hb is kinetically controlled to prevail over direct binding with β-chains and is also thermodynamically controlled by the α-Hb redox state and not the liganded state of the ferrous α-Hb. The dramatic instability of isolated ferric α-Hb is greatly decreased upon AHSP binding. Removing the bis-histidyl hexacoordination in α-HbH58(E7)Q:AHSP complex reduces the stabilizing effect of AHSP binding. Once the ferric α-Hb is bound to AHSP, the globin can be more easily reduced by several chemical and enzymatic systems compared to α-Hb within the Hb-tetramer. α-Hb reduction could trigger its release from AHSP toward its final Hb β-chain partner producing functional ferrous Hb-tetramers. This work indicates a preferred kinetic pathway for Hb-synthesis. The cellular redox balance in Hb-synthesis should be considered as important as the relative proportional synthesis of both Hb-subunits and their heme cofactor. The in vivo role of AHSP is discussed in the context of the molecular disorders observed in thalassemia. © 2013 Elsevier B.V. All rights reserved.

  17. Prevalence of Diabetes and Prediabetes according to Fasting Plasma Glucose and HbA1c

    Science.gov (United States)

    Jeon, Ja Young; Ko, Seung-Hyun; Kwon, Hyuk-Sang; Kim, Nan Hee; Kim, Jae Hyeon; Kim, Chul Sik; Song, Kee-Ho; Won, Jong Chul; Lim, Soo; Choi, Sung Hee; Jang, Myoung-jin; Kim, Yuna; Oh, Kyungwon

    2013-01-01

    Background Due to the inconvenience of performing oral glucose tolerance tests and day to day variability in glucose level, glycated hemoglobin (HbA1c) has been recommended by the American Diabetes Association as a method to diagnose diabetes. In addition, the Korean Diabetes Association has also recommended the use of HbA1c as a diagnostic test for diabetes. In this study, we evaluated the prevalence of diabetes according to fasting plasma glucose (FPG) level only or the combination of FPG and HbA1c tests. Methods Data from the 2011 Korea National Health and Nutrition Examination Survey (KNHANES) were analyzed. Among 5,811 subjects aged 30 years or older, 5,020 were selected after excluding the data of fasting time <8 hours, missing values from fasting glucose or HbA1c level, previous diagnosis of diabetes made by physicians, or current use of antidiabetic medications. Diabetes was defined as FPG ≥126 mg/dL, previous diagnosis of diabetes made by a medical doctor, current use of antidiabetic medications, and/or HbA1c ≥6.5%. Prediabetes was defined as FPG of 100 to 125 mg/dL and/or HbA1c of 5.7% to 6.4%. Results When we used FPG only, the prevalence of diabetes and prediabetes were 10.5% (men, 12.6%; women, 8.5%) and 19.3% (men, 23.8%; women, 14.9%), respectively. When HbA1c was included as a diagnostic test, the prevalence of diabetes and prediabetes increased to 12.4% (men, 14.5%; women, 10.4%) and 38.3% (men, 41%; women, 35.7%), respectively. Participants with HbA1c ≥6.5% and fasting glucose level <126 mg/dL were older and had lower estimated glomerular filtration rate. Conclusion We concluded that using fasting glucose level only may result in an underestimation of diabetes and prediabetes. HbA1c is an acceptable complementary diagnostic test for diabetes in Korean patients. However, national standardization is needed to order to use HbA1c as a diagnostic method of diabetes and prediabetes. PMID:24199164

  18. Prevalence of Diabetes and Prediabetes according to Fasting Plasma Glucose and HbA1c

    Directory of Open Access Journals (Sweden)

    Ja Young Jeon

    2013-10-01

    Full Text Available BackgroundDue to the inconvenience of performing oral glucose tolerance tests and day to day variability in glucose level, glycated hemoglobin (HbA1c has been recommended by the American Diabetes Association as a method to diagnose diabetes. In addition, the Korean Diabetes Association has also recommended the use of HbA1c as a diagnostic test for diabetes. In this study, we evaluated the prevalence of diabetes according to fasting plasma glucose (FPG level only or the combination of FPG and HbA1c tests.MethodsData from the 2011 Korea National Health and Nutrition Examination Survey (KNHANES were analyzed. Among 5,811 subjects aged 30 years or older, 5,020 were selected after excluding the data of fasting time <8 hours, missing values from fasting glucose or HbA1c level, previous diagnosis of diabetes made by physicians, or current use of antidiabetic medications. Diabetes was defined as FPG ≥126 mg/dL, previous diagnosis of diabetes made by a medical doctor, current use of antidiabetic medications, and/or HbA1c ≥6.5%. Prediabetes was defined as FPG of 100 to 125 mg/dL and/or HbA1c of 5.7% to 6.4%.ResultsWhen we used FPG only, the prevalence of diabetes and prediabetes were 10.5% (men, 12.6%; women, 8.5% and 19.3% (men, 23.8%; women, 14.9%, respectively. When HbA1c was included as a diagnostic test, the prevalence of diabetes and prediabetes increased to 12.4% (men, 14.5%; women, 10.4% and 38.3% (men, 41%; women, 35.7%, respectively. Participants with HbA1c ≥6.5% and fasting glucose level <126 mg/dL were older and had lower estimated glomerular filtration rate.ConclusionWe concluded that using fasting glucose level only may result in an underestimation of diabetes and prediabetes. HbA1c is an acceptable complementary diagnostic test for diabetes in Korean patients. However, national standardization is needed to order to use HbA1c as a diagnostic method of diabetes and prediabetes.

  19. The Glycated Albumin (GA) to HbA1c Ratio Reflects Shorter-Term Glycemic Control than GA: Analysis of Patients with Fulminant Type 1 Diabetes.

    Science.gov (United States)

    Koga, Masafumi; Inada, Shinya; Nakao, Taisei; Kawamori, Ryuzo; Kasayama, Soji

    2017-01-01

    Glycated albumin (GA) reflects shorter-term glycemic control than HbA1c. We have reported that HbA1c is paradoxically increased in diabetic patients whose glycemic control deteriorated before ameliorating. In this study, we analyzed paradoxical increases of glycemic control indicators after treatment in patients with fulminant type 1 diabetes (FT1D). We also investigated whether the GA/HbA1c ratio may reflect shorter-term glycemic control than GA. Five FT1D patients whose post-treatment HbA1c and GA levels were measured were enrolled. We also used a formula to estimate HbA1c and GA from the fictitious models of changes in plasma glucose in FT1D patients. In this model, the periods during which HbA1c, GA, and the GA/HbA1c ratio were higher than at the first visit were compared. In addition, the half-life for the GA/HbA1c ratio was calculated in accordance with the half-lives for HbA1c and GA (36 and 14 days, respectively). In all FT1D patients, HbA1c levels 2-4 weeks after treatment were increased, with three patients (60%) experiencing an increase of GA levels. In contrast, an increase of the GA/HbA1c ratio was observed in only one patient. In all of the different models of changes in plasma glucose in FT1D patients, the length of time during which the values were higher than at the first visit was in the order of HbA1c > GA > GA/HbA1c ratio. The half-life for the GA/HbA1c ratio was 9 days, shorter than GA. These findings suggest that the GA/HbA1c ratio reflects shorter-term glycemic control than GA. © 2016 Wiley Periodicals, Inc.

  20. Trimester-specific reference intervals for haemoglobin A(1c) (HbA(1c)) in pregnancy.

    LENUS (Irish Health Repository)

    O'Connor, Catherine

    2011-11-26

    Abstract Background: Diabetes in pregnancy imposes additional risks to both mother and infant. These increased risks are considered to be primarily related to glycaemic control which is monitored by means of glycated haemoglobin (HbA(1c)). The correlation of HbA(1c) with clinical outcomes emphasises the need to measure HbA(1c) accurately, precisely and for correct interpretation, comparison to appropriately defined reference intervals. Since July 2010, the HbA(1c) assay in Irish laboratories is fully metrologically traceable to the IFCC standard. The objective was to establish trimester-specific reference intervals in pregnancy for IFCC standardised HbA(1c) in non-diabetic Caucasian women. Methods: The authors recruited 311 non-diabetic Caucasian pregnant (n=246) and non-pregnant women (n=65). A selective screening based on risk factors for gestational diabetes was employed. All subjects had a random plasma glucose <7.7 mmol\\/L and normal haemoglobin level. Pregnancy trimester was defined as trimester 1 (T1, n=40) up to 12 weeks +6 days, trimester 2 (T2, n=106) 13-27 weeks +6 days, trimester 3 (T3, n=100) >28 weeks to term. Results: The normal HbA(1c) reference interval for Caucasian non-pregnant women was 29-37 mmol\\/mol (Diabetes Control and Complications Trial; DCCT: 4.8%-5.5%), T1: 24-36 mmol\\/mol (DCCT: 4.3%-5.4%), T2: 25-35 mmol\\/mol (DCCT: 4.4%-5.4%) and T3: 28-39 mmol\\/mol (DCCT: 4.7%-5.7%). HbA(1c) was significantly decreased in trimesters 1 and 2 compared to non-pregnant women. Conclusions: HbA(1c) trimester-specific reference intervals are required to better inform the management of pregnancies complicated by diabetes.

  1. Fetal Anemia and Hydrops Fetalis Associated with Homozygous Hb Constant Spring (HBA2: c.427T > C).

    Science.gov (United States)

    He, Yi; Zhao, Ying; Lou, Ji-Wu; Liu, Yan-Hui; Li, Dong-Zhi

    2016-01-01

    Hb Constant Spring (Hb CS, HBA2: c.427T > C) is a common nondeletional α-thalassemia (α-thal) that results from a nucleotide substitution at the termination codon of the α2-globin gene. Homozygosity for Hb CS (α(CS)α/α(CS)α) is relatively rare, and generally characterized with mild hemolytic anemia, jaundice, and splenomegaly. In this report we present a fetus with cardiomegaly, pericardial effusion, enlarged placenta and increased middle cerebral artery-peak systolic velocity (MCA-PSV) at 24 weeks' gestation. Fetal blood sampling revealed the severe anemia [hemoglobin (Hb) level being 4.8 g/dL] and Hb H (β4) disease-like hematological findings with Hb Bart's (γ4) level of 17.9%. DNA sequencing of the α-globin genes found that both partners were Hb CS carriers and the fetus was an Hb CS homozygote. Therefore, this was a rare case of homozygous Hb CS which demonstrated an unusual and serious anemia and hydrops fetalis in utero.

  2. First Case of a Compound Heterozygosity for Two Nondeletional α-Thalassemia mutations, Hb Constant Spring and Hb Quong Sze.

    Science.gov (United States)

    Zhou, Jian-Ying; Yan, Jin-Mei; Li, Jian; Li, Dong-Zhi

    2016-06-01

    Nondeletional α-thalassemia (α-thal) is the result of point mutations in critical regions of the α-globin genes, affecting mRNA processing, mRNA translation, or α-globin stability. Hb Constant Spring (Hb CS, HBA2: c.427T > C) is the most common nondeletional α-thal that results from a nucleotide substitution at the termination codon of the α2-globin gene. Hb Quong Sze (Hb QS, HBA2: c.377T > C) is another nondeletional α-thal in South China with the missense mutation at codon 125 of the α2-globin gene making this hemoglobin (Hb) variant highly unstable. Although homozygosity for Hb CS (α(CS)α/α(CS)α) or Hb QS (α(QS)α/α(QS)α) has been reported, clinical pictures vary from severe hemolysis that developed early in life to only mild anemia, no clinical phenotypic data of compound heterozygosity for Hb CS/Hb QS (α(CS)α/α(QS)α) has been described. In this report we describe an adult case with such a compound heterozygosity who presented with a mild α-thal.

  3. Impact of demographics and disease progression on the relationship between glucose and HbA1c.

    Science.gov (United States)

    Claussen, Anetta; Møller, Jonas B; Kristensen, Niels R; Klim, Søren; Kjellsson, Maria C; Ingwersen, Steen H; Karlsson, Mats O

    2017-06-15

    Several studies have shown that the relationship between mean plasma glucose (MPG) and glycated haemoglobin (HbA1c) may vary across populations. Especially race has previously been referred to shift the regression line that links MPG to HbA1c at steady-state (Herman & Cohen, 2012). To assess the influence of demographic and disease progression-related covariates on the intercept of the estimated linear MPG-HbA1c relationship in a longitudinal model. Longitudinal patient-level data from 16 late-phase trials in type 2 diabetes with a total of 8927 subjects was used to study covariates for the relationship between MPG and HbA1c. The analysed covariates included age group, BMI, gender, race, diabetes duration, and pre-trial treatment. Differences between trials were taken into account by estimating a trial-to-trial variability component. Participants included 47% females and 20% above 65years. 77% were Caucasian, 9% were Asian, 5% were Black and the remaining 9% were analysed together as other races. Estimates of the change in the intercept of the MPG-HbA1c relationship due to the mentioned covariates were determined using a longitudinal model. The analysis showed that pre-trial treatment with insulin had the most pronounced impact associated with a 0.34% higher HbA1c at a given MPG. However, race, diabetes duration and age group also had an impact on the MPG-HbA1c relationship. Our analysis shows that the relationship between MPG and HbA1c is relatively insensitive to covariates, but shows small variations across populations, which may be relevant to take into account when predicting HbA1c response based on MPG measurements in clinical trials. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Significant association of serum creatinine with HbA1C in impaired glucose tolerant Pakistani subjects.

    Science.gov (United States)

    Farasat, Tasnim; Sharif, Saima; Naz, Shagufta; Fazal, Sabiha

    2015-01-01

    The present study was conducted to assess the serum concentration of creatinine and determine its relationship with potential risk factors of diabetes in Impaired Glucose tolerance subjects. This cross sectional study was conducted on 100 IGT patients who attended Amin Hayat diabetic center in Lahore from January 2011- June 2011. Patients with age group 34-67 years, (both sexes) were included in the study. Different demographic parameters as age, BMI, WHR, B.P, personal history and socioeconomic status were recorded. Oral Glucose Tolerance Test was performed. The biochemical parameters including HbA1c, lipid profile, urea, uric acid, creatinine and bilirubin level were measured by chemistry analyzer. A strong correlation between creatinine and HbA1c was observed. The level of creatinine was also significantly associated with age in IGT subjects. Creatinine is non-significantly correlated with Cholesterol, LDL-Chol and TG while negatively significantly associated with BMI, fasting blood glucose and HDL-Chol. The present study concluded significant association of serum creatinine with HbA1c, BMI and HDL cholesterol.

  5. HbA1c and Gestational Weight Gain Are Factors that Influence Neonatal Outcome in Mothers with Gestational Diabetes.

    Science.gov (United States)

    Barquiel, Beatriz; Herranz, Lucrecia; Hillman, Natalia; Burgos, Ma Ángeles; Grande, Cristina; Tukia, Keleni M; Bartha, José Luis; Pallardo, Luis Felipe

    2016-06-01

    Maternal glucose and weight gain are related to neonatal outcome in women with gestational diabetes mellitus (GDM). The aim of this study was to explore the influence of average third-trimester HbA1c and excess gestational weight gain on GDM neonatal complications. This observational study included 2037 Spanish singleton pregnant women with GDM followed in our Diabetes and Pregnancy Unit. The maternal HbA1c level was measured monthly from GDM diagnosis to delivery. Women were compared by average HbA1c level and weight gain categorized into ≤ or > the current Institute of Medicine (IOM) recommendations for body mass index. The differential effects of these factors on large-for-gestational-age birth weight and a composite of neonatal complications were assessed. Women with an average third-trimester HbA1c ≥5.0% (n = 1319) gave birth to 7.3% versus 3.8% (p = 0.005) of large-for-gestational-age neonates and 22.0% versus 16.0% (p = 0.006) of neonates with complications. Women with excess gestational weight gain (n = 299) delivered 12.5% versus 5.2% (p gestational-age neonates and 24.7% versus 19.0% (p = 0.022) of neonates with complications. In an adjusted multiple logistic regression analysis among mothers exposed to the respective risk factors, ∼47% and 52% of large-for-gestational-age neonates and 32% and 37% of neonatal complications were potentially preventable by attaining an average third-trimester HbA1c level gestational weight gain. Average third-trimester HbA1c level ≥5% and gestational weight gain above the IOM recommendation are relevant risk factors for neonatal complications in mothers with gestational diabetes.

  6. "SERUM FERRITIN IN TYPE 2 DIABETES MELLITUS AND ITS RELATIONSHIP WITH HbA1c"

    Directory of Open Access Journals (Sweden)

    F. Sharifi Sh. Sazandeh

    2004-06-01

    Full Text Available Diabetes mellitus (DM type 2 is one of the most common endocrine disorders affecting more than 135 million people in the world. The etiology of the disease is not fully understood, but recently subclinical hemochromatosis has been considered as one of the probable causes of DM. This study was carried out to examine the relationship between serum ferritin as a marker of iron overload with DM and HbA1c. This study was conducted on 97 patients with type 2 DM who were referred to Zanjan Diabetes Clinic. Ninety-four normal age-matched individuals were included in the study as the control group. Ferritin, hemoglobin, HbA1c, and fasting blood sugar were measured in blood samples. Exclusion criteria included anemia, or any other disease or drug that could affect ferritin levels. Results were analyzed statistically by Chi-square test, t-test and Pearson regression coefficient test. One hundred ninety-one cases including 97 diabetics (37 males and 60 females and 94 normal individuals were studied. There were no significant differences between the two groups regarding age, hemoglobin and body mass index. Mean serum ferritin was significantly higher in diabetics than in the control group (101±73 mg/ml vs. 43.5+42 mg/ml, p<0.001. There was no correlation between serum ferritin and HbA1c in diabetic patients of either sex. Ferritin levels in patients with DM is high, but not related to levels of HbA1c and blood glucose control.

  7. Hemoglobin A1c (HbA1c) Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/hemoglobina1chba1ctest.html Hemoglobin A1c (HbA1c) Test To use the sharing features on this page, please enable JavaScript. What is a hemoglobin A1c (HbA1c) test? A hemoglobin A1c (HbA1c) test measures ...

  8. Associations of mid-pregnancy HbA1c with gestational diabetes and risk of adverse pregnancy outcomes in high-risk Taiwanese women.

    Science.gov (United States)

    Ho, Yi-Ran; Wang, Panchalli; Lu, Mei-Chun; Tseng, Shih-Ting; Yang, Chun-Pai; Yan, Yuan-Horng

    2017-01-01

    The objective of this study was to investigate the associations among the mid-pregnancy glycated hemoglobin A1c (HbA1c) level, gestational diabetes (GDM), and risk of adverse pregnancy outcomes in women without overt diabetes and with positive 50-g, 1-h glucose challenge test (GCT) results (140 mg/dL or greater). This prospective study enrolled 1,989 pregnant Taiwanese women. A two-step approach, including a 50-g, 1-h GCT and 100-g, 3-h oral glucose tolerance test (OGTT), was employed for the diagnosis of GDM at weeks 23-32. The mid-pregnancy HbA1c level was measured at the time the OGTT was performed. A receiver operating characteristic (ROC) curve was used to determine the relationship between the mid-pregnancy HbA1c level and GDM. Multiple logistic regression models were implemented to assess the relationships between the mid-pregnancy HbA1c level and adverse pregnancy outcomes. An ROC curve demonstrated that the optimal mid-pregnancy HbA1c cut-off point to predict GDM, as diagnosed by the Carpenter-Coustan criteria using a two-step approach, was 5.7%. The area under the ROC curve of the mid-pregnancy HbA1c level for GDM was 0.70. Compared with the levels of 4.5-4.9%, higher mid-pregnancy HbA1c levels (5.0-5.4, 5.5-5.9, 6.0-6.4, 6.5-6.9, and >7.0%) were significantly associated with increased risks of gestational hypertension or preeclampsia, preterm delivery, admission to the neonatal intensive care unit, low birth weight, and macrosomia (the odds ratio [OR] ranges were 1.20-9.98, 1.31-5.16, 0.88-3.15, 0.89-4.10, and 2.22-27.86, respectively). The mid-pregnancy HbA1c level was associated with various adverse pregnancy outcomes in high-risk Taiwanese women. However, it lacked adequate sensitivity and specificity to replace the two-step approach in the diagnosis of GDM. The current study comprised a single-center prospective study; thus, additional, randomized control design studies are required.

  9. The association between estimated average glucose levels and fasting plasma glucose levels in a rural tertiary care centre

    Directory of Open Access Journals (Sweden)

    Raja Reddy P

    2013-01-01

    Full Text Available The level of hemoglobin A1c (HbA1c, also known as glycated hemoglobin, determines how well a patient’s blood glucose level has been controlled over the previous 8-12 weeks. HbA1c levels help patients and doctors understand whether a particular diabetes treatment is working and whether adjustments need to be made to the treatment. Because the HbA1c level is a marker of blood glucose for the previous 60- 90 days, average blood glucose levels can be estimated using HbA1c levels. Aim in the present study was to investigate the relationship between estimated average glucose levels, as calculated by HbA1c levels, and fasting plasma glucose levels. Methods: Type 2 diabetes patients attending medicine outpatient department of RL Jalappa hospital, Kolar between March 2010 and July 2012 were taken. The estimated glucose levels (mg/dl were calculated using the following formula: 28.7 x HbA1c-46.7. Glucose levels were determined using the hexokinase method. HbA1c levels were determined using an HPLC method. Correlation and independent t- test was the test of significance for quantitative data. Results: A strong positive correlation between fasting plasma glucose level and estimated average blood glucose levels (r=0.54, p=0.0001 was observed. The difference was statistically significant. Conclusion: Reporting the estimated average glucose level together with the HbA1c level is believed to assist patients and doctors determine the effectiveness of blood glucose control measures.

  10. LLL transient-electromagnetics-measurement facility

    International Nuclear Information System (INIS)

    Deadrick, F.J.; Miller, E.K.; Hudson, H.G.

    1975-01-01

    The operation and hardware of the Lawrence Livermore Laboratory's transient-electromagnetics (EM)-measurement facility are described. The transient-EM range is useful for determining the time-domain transient responses of structures to incident EM pulses. To illustrate the accuracy and utility of the EM-measurement facility, actual experimental measurements are compared to numerically computed values

  11. Facility level SSAC for model country - an introduction and material balance accounting principles

    International Nuclear Information System (INIS)

    Jones, R.J.

    1989-01-01

    A facility level State System of Accounting for and Control of Nuclear Materials (SSAC) for a model country and the principles of materials balance accounting relating to that country are described. The seven principal elements of a SSAC are examined and a facility level system based on them discussed. The seven elements are organization and management; nuclear material measurements; measurement quality; records and reports; physical inventory taking; material balance closing; containment and surveillance. 11 refs., 19 figs., 5 tabs

  12. HbA1c as a predictor of diabetes after gestational diabetes mellitus.

    Science.gov (United States)

    Claesson, Rickard; Ignell, Claes; Shaat, Nael; Berntorp, Kerstin

    2017-02-01

    We wanted to investigate third-trimester HbA1c as a predictor of diabetes after gestational diabetes mellitus (GDM). Women with GDM were followed up prospectively for five years from pregnancy to detect the development of diabetes. The ability of HbA1c to predict diabetes was evaluated with receiver-operating characteristic (ROC) curves and logistic regression analysis. By five years, 73 of 196 women had been diagnosed with diabetes. An optimal cut-off point for HbA1c of 36mmol/mol (5.4%) could predict diabetes with 45% sensitivity and 92% specificity. For HbA1c ≥39mmol/mol (≥5.7%), sensitivity, specificity, and positive predictive value were 30%, 97%, and 91%, respectively. In logistic regression analysis, adjusting for the diagnostic glucose concentration during pregnancy, HbA1c levels in the upper quartile (≥36mmol/mol) were associated with a 5.5-fold increased risk of diabetes. Third-trimester HbA1c levels in the pre-diabetes range revealed women with post-partum diabetes with high specificity and high positive predictive value. HbA1c testing could be used as a strategy to select high-risk women for lifestyle interventions aimed at prevention of diabetes starting during pregnancy. The results should encourage further validation in other populations using new diagnostic criteria for GDM. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. A study assessing the association of glycated hemoglobin A1C (HbA1C) associated variants with HbA1C, chronic kidney disease and diabetic retinopathy in populations of Asian ancestry.

    Science.gov (United States)

    Chen, Peng; Ong, Rick Twee-Hee; Tay, Wan-Ting; Sim, Xueling; Ali, Mohammad; Xu, Haiyan; Suo, Chen; Liu, Jianjun; Chia, Kee-Seng; Vithana, Eranga; Young, Terri L; Aung, Tin; Lim, Wei-Yen; Khor, Chiea-Chuen; Cheng, Ching-Yu; Wong, Tien-Yin; Teo, Yik-Ying; Tai, E-Shyong

    2013-01-01

    Glycated hemoglobin A1C (HbA1C) level is used as a diagnostic marker for diabetes mellitus and a predictor of diabetes associated complications. Genome-wide association studies have identified genetic variants associated with HbA1C level. Most of these studies have been conducted in populations of European ancestry. Here we report the findings from a meta-analysis of genome-wide association studies of HbA1C levels in 6,682 non-diabetic subjects of Chinese, Malay and South Asian ancestries. We also sought to examine the associations between HbA1C associated SNPs and microvascular complications associated with diabetes mellitus, namely chronic kidney disease and retinopathy. A cluster of 6 SNPs on chromosome 17 showed an association with HbA1C which achieved genome-wide significance in the Malays but not in Chinese and Asian Indians. No other variants achieved genome-wide significance in the individual studies or in the meta-analysis. When we investigated the reproducibility of the findings that emerged from the European studies, six loci out of fifteen were found to be associated with HbA1C with effect sizes similar to those reported in the populations of European ancestry and P-value ≤ 0.05. No convincing associations with chronic kidney disease and retinopathy were identified in this study.

  14. A study assessing the association of glycated hemoglobin A1C (HbA1C associated variants with HbA1C, chronic kidney disease and diabetic retinopathy in populations of Asian ancestry.

    Directory of Open Access Journals (Sweden)

    Peng Chen

    Full Text Available Glycated hemoglobin A1C (HbA1C level is used as a diagnostic marker for diabetes mellitus and a predictor of diabetes associated complications. Genome-wide association studies have identified genetic variants associated with HbA1C level. Most of these studies have been conducted in populations of European ancestry. Here we report the findings from a meta-analysis of genome-wide association studies of HbA1C levels in 6,682 non-diabetic subjects of Chinese, Malay and South Asian ancestries. We also sought to examine the associations between HbA1C associated SNPs and microvascular complications associated with diabetes mellitus, namely chronic kidney disease and retinopathy. A cluster of 6 SNPs on chromosome 17 showed an association with HbA1C which achieved genome-wide significance in the Malays but not in Chinese and Asian Indians. No other variants achieved genome-wide significance in the individual studies or in the meta-analysis. When we investigated the reproducibility of the findings that emerged from the European studies, six loci out of fifteen were found to be associated with HbA1C with effect sizes similar to those reported in the populations of European ancestry and P-value ≤ 0.05. No convincing associations with chronic kidney disease and retinopathy were identified in this study.

  15. Hydroxyurea decreases hospitalizations in pediatric patients with Hb SC and Hb SB+ thalassemia

    Directory of Open Access Journals (Sweden)

    Lebensburger JD

    2015-12-01

    Full Text Available Jeffrey D Lebensburger, Rakeshkumar J Patel, Prasannalaxmi Palabindela, Christina J Bemrich-Stolz, Thomas H Howard, Lee M HilliardDivision of Pediatric Hematology Oncology, University of Alabama at Birmingham, Birmingham, AL, USAPurpose: Patients with hemoglobin SC (Hb SC and hemoglobin SB+ (Hb SB+ thalassemia suffer from frequent hospitalizations yet strong evidence of a clinical benefit of hydroxyurea (HU in this population is lacking. Patients with recurrent hospitalizations for pain crisis are offered HU at our institution based on small cohort data and anecdotal benefit. This study identifies outcomes from a large cohort of patients with Hb SC and SB+ thalassemia who were treated with HU for 2 years.Materials and methods: A retrospective review was conducted of 32 patients with Hb SC and SB+ thalassemia who were treated with HU. We reviewed the number, and reasons for hospitalization in the 2 years prior to, and 2 years post-HU treatment as well as laboratory changes from baseline, over 1 year.Results: Patients with Hb SC and SB+ thalassemia started on HU for frequent pain, had a significant reduction in hospitalizations over 2 years as compared to the 2 years prior to HU initiation (mean total hospitalizations/year: pre-HU: 1.6 vs post-HU 0.4 hospitalizations, P<0.001; mean pain hospitalizations/year: pre-HU 1.5 vs post-HU 0.3 hospitalizations, P<0.001. Patients demonstrated hematologic changes including an increase in percent fetal hemoglobin (%HbF pre–post HU (4.5% to 7.7%, P=0.002, mean corpuscular volume (74 to 86 fL, P<0,0001, and decrease in absolute neutrophil count (5.0 to 3.2×109/L, P=0.007. Patients with higher doses of HU demonstrated the greatest reduction in hospitalizations but this was unrelated to absolute neutrophil count.Conclusion: This cohort of patients with Hb SC and SB+ thalassemia provides additional support for using HU in patients with recurrent hospitalizations for pain. A large randomized multicenter trial of

  16. Plasma microRNA-451 as a novel hemolytic marker for β0-thalassemia/HbE disease

    Science.gov (United States)

    Leecharoenkiat, Kamonlak; Tanaka, Yuka; Harada, Yasuko; Chaichompoo, Porntip; Sarakul, Orawan; Abe, Yasunobu; Smith, Duncan Richard; Fucharoen, Suthat; Svasti, Saovaros; Umemura, Tsukuru

    2017-01-01

    In Southeast Asia, particularly in Thailand, β0-thalassemia/hemoglobin E (HbE) disease is a common hereditary hematological disease. It is associated with pathophysiological processes, such as the intramedullary destruction of immature erythroid cells and peripheral hemolysis of mature red blood cells. MicroRNA (miR) sequences, which are short non-coding RNA that regulate gene expression in a suppressive manner, serve a crucial role in human erythropoiesis. In the present study, the plasma levels of the erythroid-expressed miRNAs, miR-451 and miR-155, were analyzed in 23 patients with β0-thalassemia/HbE and 16 control subjects. Reverse transcription-quantitative polymerase chain reaction analysis revealed significantly higher levels of plasma miR-451 and miR-155 in β0-thalassemia/HbE patients when compared to the control subjects. Notably, among the β0-thalassemia/HbE patients, a significant increase in miR-451 levels was detected in severe cases when compared with mild cases. The levels of plasma miR-451 correlated with reticulocyte and platelet counts. The results suggest that increased plasma miR-451 levels may be associated with the degree of hemolysis and accelerated erythropoiesis in β0-thalassemia/HbE patients. In conclusion, miR-451 may represent a relevant biomarker for pathological erythropoiesis associated with β0-thalassemia/HbE. PMID:28447765

  17. Validation and determination of a reference interval for canine HbA1c using an immunoturbidimetric assay.

    Science.gov (United States)

    Goemans, Anne F; Spence, Susanna J; Ramsey, Ian K

    2017-06-01

    Hemoglobin A1c (HbA1c) provides a reliable measure of glycemic control over 2-3 months in human diabetes mellitus. In dogs, presence of HbA1c has been demonstrated, but there are no validated commercial assays. The purpose of the study was to validate a commercially available automated immunoturbidimetric assay for canine HbA1c and determine an RI in a hospital population. The specificity of the assay was assessed by inducing glycosylation in vitro using isolated canine hemoglobin, repeatability by measuring canine samples 5 times in succession, long term inter-assay imprecision by measuring supplied control materials, stability using samples stored at 4°C over 5 days and -20°C over 8 weeks, linearity by mixing samples of known HbA1c in differing proportions, and the effect of anticoagulants with paired samples. An RI was determined using EDTA-anticoagulated blood samples from 60 nondiabetic hospitalized animals of various ages and breeds. Hemoglobin A1c was also measured in 10 diabetic dogs. The concentration of HbA1c increased proportionally with glucose concentration in vitro. For repeat measurements, the CV was 4.08% (range 1.16-6.10%). Samples were stable for 5 days at 4°C. The assay was linear within the assessed range. Heparin- and EDTA-anticoagulated blood provided comparable results. The RI for HbA1c was 9-18.5 mmol/mol. There was no apparent effect of age or breed on HbA1c. In diabetic dogs, HbA1c ranged from 14 to 48 mmol/mol. The assay provides a reliable method for canine HbA1c measurement with good analytic performance. © 2017 American Society for Veterinary Clinical Pathology.

  18. Empirically establishing blood glucose targets to achieve HbA1c goals.

    Science.gov (United States)

    Wei, Nancy; Zheng, Hui; Nathan, David M

    2014-04-01

    OBJECTIVE To determine the average fasting, postprandial, and bedtime self-monitored blood glucose (SMBG) concentrations associated with specified HbA1c levels using data from the A1c-Derived Average Glucose (ADAG) study. RESEARCH DESIGN AND METHODS The ADAG study was a multicenter observational study that used continuous glucose monitoring and SMBG testing to determine the relationship between mean average glucose and HbA1c. We used the SMBG data from 470 of the ADAG study participants (237 with type 1 diabetes and 147 with type 2 diabetes) to determine the average fasting, premeal, 90-min postmeal, and bedtime blood glucose (BG) for predefined target HbA1c groups between 5.5 and 8.5% (37-69 mmol/mol). t Tests were used to compare mean BG values between type 1 and type 2 diabetes groups. RESULTS The average fasting BG needed to achieve predefined HbA1c target levels of 5.5-6.49% (37-47 mmol/mol), 6.5-6.99% (48-52 mmol/mol), 7.0-7.49% (52-58 mmol/mol), 7.5-7.99% (58-64 mmol/mol), and 8.0-8.5% (64-69 mmol/mol) were 122 mg/dL with 95% CI 117-127, 142 mg/dL (135-150), 152 mg/dL (143-162), 167 mg/dL (157-177), and 178 mg/dL (164-192), respectively. Postmeal BG to achieve the HbA1c level of 6.5-6.99% (48-52 mmol/mol) and 7.0-7.49% (52-58 mmol/mol) were 139 mg/dL (134-144) and 152 mg/dL (147-157), respectively. Bedtime BG was 153 mg/dL (145-161) and 177 mg/dL (166-188), respectively. CONCLUSIONS We have determined the average BG at premeal, postmeal, and bedtime to achieve a variety of HbA1c targets. These results, based on empirical data, will help patients and providers set realistic day-to-day SMBG targets to achieve individualized HbA1c goals.

  19. Measurement of photoneutron spectrum at Pohang Neutron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G.N.; Kovalchuk, V.; Lee, Y.S.; Skoy, V.; Cho, M.H.; Ko, I.S.; Namkung, W. [POSTECH, Pohang Accelerator Laboratory, Pohang, Kyungbuk (Korea)

    2001-03-01

    Pohang Neutron Facility, which is the pulsed neutron facility based on the 100-MeV electron linear accelerator, was constructed for nuclear data production in Korea. The Pohang Neutron Facility consists of an electron linear accelerator, a water-cooled Ta target with a water moderator and a time-of-flight path with an 11 m length. The neutron energy spectra are measured for different water levels inside the moderator and compared with the MCNP calculation. The optimum size of the water moderator is determined on the base of this result. The time dependent spectra of neutrons in the water moderator are investigated with the MCNP calculation. (author)

  20. Use of point-of-care HbA1c measurement to estimate the level of undiagnosed diabetes mellitus among 67-year-old participants in a cardiovascular screening programme in the municipality of Viborg, Denmark

    DEFF Research Database (Denmark)

    Andersen, Jesper Winkler; Dahl, Marie; Yderstræde, Knud Bonnet

    2018-01-01

    Aims To determine the prevalence of unidentified diabetes mellitus among 67‐year‐olds in Denmark participating in a screening programme focusing on cardiovascular disease and diabetes, and to describe glycaemic levels in individuals according to point‐of‐care HbA1c combined with self‐reported dia...

  1. Influence of Erythropoiesis-Stimulating Agents on HbA1c and Fructosamine in Patients with Haemodialysis.

    Science.gov (United States)

    Rasche, Franz Maximilian; Ebert, Thomas; Beckmann, Julia; Busch, Volker; Barinka, Filip; Rasche, Wilma Gertrud; Lindner, Tom H; Schneider, Jochen G; Schiekofer, Stephan

    2017-06-01

    HbA1c is the most accepted laboratory parameter for the long term observation of glucose control. There is still much of a debate about the use of HbA1c as a metabolic indicator in diabetic patients (DM) on haemodialysis (HD) and erythropoiesis-stimulating agent (ESA) therapy because of the altered erythrocyte turn over in patients with chronic kidney disease and haemodialysis (CKD5D). In 102 CKD5 patients with and without diabetes mellitus, we examined the dose dependent variability in HbA1c and fructosamine levels under haemodialysis and treated with epoetin α (n=48) and a new generation agent with continuous stimulation of methoxy polyethylene glycol epoetin beta (C.E.R.A.; n=54). HbA1c levels were affected by therapy with ESA treatments. ESA dose was inversely correlated with HbA1c and an escalation of 10.000 IU per week induced an estimated decrease of HbA1c of 0.6 percent. In addition, the increase of reticulocyte number as a marker for erythropoiesis was significantly inversely correlated with the increase of ΔHbA1c. ESA treatments had no such effect on the alternative metabolic parameter fructosamine. When compared, both therapeutic agents had comparable success in attaining haemoglobin (Hb) target values. C.E.R.A. showed better correlation and was more effective over a longer dose interval. Our results show that HbA1c levels in patients should be carefully interpreted based on interfering factors. Nevertheless, HbA1c is currently the most consistent parameter for use ascertaining metabolic status of patients suffering from diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Hb and dyslipidaemia as predicting markers of serum alanine aminotransferase elevation in Chinese adolescents.

    Science.gov (United States)

    Chao, Kuo-Ching; Chang, Chun-Chao; Owaga, Eddy; Bai, Chyi-Huey; Huang, Tzu-chieh; Pan, Wen-Harn; Chang, Jung-Su

    2016-04-01

    Fe is an essential element for erythropoiesis and Hb synthesis. High Hb levels affect the blood's viscosity and are associated with cardiovascular dysfunction. The aim of the present study was to examine relationships of Hb and cardiometabolic abnormalities with the risk of alanine aminotransferase (ALT) elevation in adolescents. A population-based, cross-sectional study. National Nutrition and Health Survey in Taiwan (2010-2011, adolescents). Healthy adolescents aged 13-18 years. In total, 1941 adolescents (963 boys and 978 girls) were entered in the study. The mean age was 15·3 (sd 0·1) years (boys, 15·3 (sd 0·1) years; girls, 15·2 (sd 0·1) years). ALT tertile cut-off points for boys were 11 and 16 U/l, and for girls were 9 and 12 U/l. Girls without dyslipidaemia and presenting in the highest quartile (Q1) of Hb (>13·6 g/dl) were 1·89 and 3·76 times more likely to have raised serum ALT (9 and >12 U/l, respectively) than the reference (lowest quartile of Hb (Q1), 12 U/l) than the reference (Q1 of Hb, 15·4 g/dl), who were 7·40 times more likely to have elevated serum ALT of >16 U/l than the reference (Q1 of Hb, Hb level is a predictor of elevated serum ALT in adolescent girls with dyslipidaemia. Our study also highlights the importance of further research to establish cut-off points for Hb and its utility in diagnosing and preventing the onset of dyslipidaemia in adolescents.

  3. Exploring factors influencing HbA1c and psychosocial outcomes in people with type 1 diabetes after training in advanced carbohydrate counting.

    Science.gov (United States)

    Schmidt, Signe; Vistisen, Dorte; Almdal, Thomas; Hommel, Eva; Nørgaard, Kirsten

    2017-08-01

    The purpose of this secondary analysis of the StenoABC Study was to identify determinants of the changes in HbA1c observed after training of people with type 1 diabetes in advanced carbohydrate counting (ACC) and automated bolus calculator (ABC) use, and further to investigate psychosocial effects of these insulin dosing approaches. Validated diabetes-specific questionnaires were used to assess diabetes treatment satisfaction, problem areas in diabetes, fear of hypoglycemia and diabetes dependent quality of life before and one year after the training. In addition, numeracy was tested (using a non-validated test developed specifically for this study) and behavioral measures (number of daily blood glucose measurements and self-reported use of ACC) were obtained. Associations between change in HbA1c and these measures plus sex, age, diabetes duration and BMI were tested. Numeracy was the only baseline predictor of yearly change in HbA1c identified. Higher levels of numeracy were associated with greater reductions in HbA1c (P=0.031). No associations between change in HbA1c and the behavioral measures investigated were found, nor were any clinically relevant associations between changes in HbA1c and questionnaire scores. Treatment satisfaction increased in all users of ACC (PHbA1c after training in ACC were inversely related to numeracy. Use of an ABC did not compensate for poor numeracy skills. However, device use reduced fear of hypoglycemia compared with ACC without ABC use. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Evaluation of the DCA Vantage analyzer for HbA 1c assay.

    Science.gov (United States)

    Szymezak, Jean; Leroy, Nathalie; Lavalard, Emmanuelle; Gillery, Philippe

    2008-01-01

    Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.

  5. Radioisotope Characterization of HB Line Low Activity Waste

    International Nuclear Information System (INIS)

    Snyder, S.J.

    1999-01-01

    The purpose of this document is to provide a physical, chemical, hazardous and radiological characterization of Low-Level Waste (LLW) generated in HB-Line as required by the 1S Manual, Savannah River Site Waste Acceptance Criteria Manual

  6. Association between HbA1c and carotid atherosclerosis among elderly Koreans with normal fasting glucose.

    Directory of Open Access Journals (Sweden)

    Seung Won Lee

    Full Text Available We examined whether glycated haemoglobin (HbA1c is associated to carotid atherosclerosis in an elderly Korean population with normal fasting glucose.Using data from the Korean Urban Rural Elderly study, we conducted a cross-sectional analysis of 1,133 participants (335 men and 798 women with a mean age of 71.8 years. All participants had fasting blood glucose less than 100mg/dL (5.6 mmol/L and HbA1c level below 6.5% (48 mmol/mol. They were also free from a history of cardiovascular disease, known type 2 diabetes mellitus or use of anti-diabetes medications. Carotid atherosclerosis was assessed by intima-media thickness (IMT using ultrasonography. The association between HbA1c and carotid IMT was investigated using multivariable linear regression analysis.HbA1c levels were independently and positively associated with carotid IMT (β = 0.020, p = 0.045 after adjusting for sex, age, body mass index, systolic blood pressure, diastolic blood pressure, triglyceride, LDL cholesterol, smoking and alcohol intake. However, fasting insulin and glucose levels were not associated with carotid IMT.HbA1c levels were positively associated with carotid atherosclerosis, as assessed by carotid IMT, in an elderly population with normoglycemia. Our study suggested that higher HbA1c level is an effective and informative marker of carotid atherosclerosis in an elderly population.

  7. Stockbridge Antenna Measurement and Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Stockbridge Antenna Measurement Facility is located 23 miles southwest of AFRL¹s Rome Research Site. This unique measurement facility is designed to evaluate the...

  8. Questionnaire survey report on measurement of radioactivity in working environment of radioisotopes facility

    International Nuclear Information System (INIS)

    Kawano, Takao; Nomura, Kiyoshi

    2008-01-01

    To look over the current measurement of radioactivity concentration in working environment of many radioisotopes facilities, a questionnaire survey was carried out under the auspices of the Planning Committee of the Japan Society of Radiation Safety Management. 64 responses were obtained in 128 radiation facilities, which the questionnaires were sent to. The main results were obtained by aggregate analysis of the answers for questionnaires as the followings. Major nuclides subject to measurement were 3 H, 14 C, 32 P and 125 I Sampling of radioisotopes in air was mainly performed using collectors like dust samplers and HC-collectors. Liquid scintillation counters and gamma counters were used to measure β and γ radioactivity contained in airborne particles or gas samples. Contamination by radioactivity was not detected in 55% facilities surveyed, but in 40% facilities at the same level as or at lower levels than a hundredth part of the regulated concentration limit of each nuclide. Almost all facilities is found to consider that the measurement of radioactivity concentration in working environments is not always necessary. (author)

  9. Complex structure of the supernova remnant HB 3

    Science.gov (United States)

    Leahy, D. A.; Venkatesan, D.; Long, K. S.; Naranan, S.

    1985-01-01

    HB 3 is an old, large (84 pc diameter) supernova remnant associated with the W3 H II region/molecular cloud complex. Observations of the imaging proportional counter (IPC) onboard the Einstein X-ray astronomy satellite have been reprocessed to yield a contour map of X-ray brightness and spectra of various regions of this remnant. The measured IPC flux is 2.4 x 10 to the -11th ergs per sq cm per s, giving a 0.2-4 keV luminosity of 1.6 x 10 to the 35th ergs/s for a column densityof 6 x 10 to the 21st per sq cm. The measured X-ray temperatures reveal a decrease from center to limb of the remnant of 1-0.3 keV. HB 3 is in the late adiabatic blast-wave phase of evolution, 30,000 to 50,000 yr old and with an initial blast energy of 3 x 10 to the 50th ergs. The X-ray map is compared with available radio and optical images. In X-rays, HB 3 has two components - a diffuse emission inside the 84 pc radio remnant and a ring of emission at the center of 30 pc in diameter. The diffuse emission is similar to that from other supernova remnants which are moderately obscured (column density, nH approximately 10 to the 22nd per sq cm). Three possibilities for the origin of the ring are explored: (1) a second supernova remnant, (2) a shocked shell in the interstellar medium surrounding HB 3, and (3) reverse-shock heated ejecta. There is no hot neutron star within the remnant.

  10. Hb H disease resulting from the association of an αº-thalassemia allele [-(α20.5] with an unstable α-globin variant [Hb Icaria]: first report on the occurrence in Brazil

    Directory of Open Access Journals (Sweden)

    Elza M. Kimura

    2009-01-01

    Full Text Available Hb H Disease is caused by the loss or inactivation of three of the four functional a-globin genes. Patients present chronic hemolytic anemia and splenomegaly. In some cases, occasional blood transfusions are required. Deletions are the main cause of this type of thalassemia (α-thalassemia. We describe here an unusual case of Hb H disease caused by the combination of a common αº deletion [-(α20.5] with a rare point mutation (c.427T > A, thus resulting in an elongated and unstable α-globin variant, Hb Icaria, (X142K, with 31 additional amino-acid residues. Very high levels of Hb H and Hb Bart's were detected in the patient's red blood cells (14.7 and 19.0%, respectively. This is the first description of this infrequent association in the Brazilian population.

  11. First Report of a Chinese Family Carrying a Double Heterozygosity for Hb Q-Thailand and Hb J-Bangkok.

    Science.gov (United States)

    Jiang, Fan; Zhou, Jian-Ying; Yan, Jin-Mei; Lu, Yue-Cheng; Li, Dong-Zhi

    2016-11-01

    The double heterozygosity for α and β chain variants leads to the formation of abnormal heterodimer hybrids, which could render laboratory diagnostics in a routine setting difficult. The following is the first report of a double heterozygosity for Hb Q-Thailand [α74(EF3)Asp→His; HBA1: c.223G>C] with α + -thalassemia (α + -thal) and Hb J-Bangkok [β56(D7)Gly→Asp; HBB: c.170G>A] found in a Chinese family. Both subjects were healthy with normal or borderline hematological parameters. Hemoglobin (Hb) analyses showed a novel variant, Hb Q-Thailand and Hb J-Bangkok. Family studies helped in the initial recognition and in making presumptive diagnoses, but definitive diagnoses of these cases with complex α and β chain variants could only be obtained after DNA analysis.

  12. A novel hemoglobin variant found on the α1 chain: Hb KSVGH (HBA1: p.Lys57_Gly58insSerHisGlySerAlaGlnValLys).

    Science.gov (United States)

    Wang, Mei-Chun; Tsai, Kuo-Wang; Chu, Chih-Hsun; Yu, Ming-Sun; Lam, Hing-Chung

    2015-01-01

    Glycosylated hemoglobin (Hb A1C) is a crucial indicator for the long-term control and the diagnosis of diabetes. However, the presence of hemoglobin (Hb) variants may affect the measured value of Hb A1C and result in an abnormal graph trend and inconsistency between the clinical blood sugar test and Hb A1C values. In this study, laboratory data of 41,267 patients with diabetes were collected. The Hb A1C levels and the graph results were examined. We identified 74 cases containing abnormal Hb A1C graph trends. The conducted blood cell counts and capillary Hb electrophoresis were used to analyze Hb variants. We also determined gene variation for the Hb variants by a sequence approach. Fifteen different types of Hb variants were identified in this study. Among these, we found a novel variant in which the α1 subunit of Hb showed an insertion of 24 nucleotides (nts) between the 56th and 57th residues. We named this novel variant Hb Kaohsiung Veterans General Hospital (Hb KSVGH) (HBA1: p.Lys57_Gly58insSerHisGlySerAlaGlnValLys).

  13. Heterogeneous behavior of lipids according to HbA1c levels undermines the plausibility of metabolic syndrome in type 1 diabetes: data from a nationwide multicenter survey

    Directory of Open Access Journals (Sweden)

    Giuffrida Fernando MA

    2012-12-01

    Full Text Available Abstract Background Cardiovascular risk factors (CVRF may cluster in type 1 diabetes, analogously to the metabolic syndrome described in type 2 diabetes. The threshold of HbA1c above which lipid variables start changing behavior is unclear. This study aims to 1 assess the behavior of dyslipidemia according to HbA1c values; 2 detect a threshold of HbA1c beyond which lipids start to change and 3 compare the clustering of lipids and other non-lipid CVRF among strata of HbA1c individuals with type 1 diabetes. Methods Effects of HbA1c quintiles (1st: ≤7.4%; 2nd: 7.5-8.5%; 3rd: 8.6-9.6%; 4th: 9.7-11.3%; and 5th: >11.5% and covariates (gender, BMI, blood pressure, insulin daily dose, lipids, statin use, diabetes duration on dyslipidemia were studied in 1275 individuals from the Brazilian multi-centre type 1 diabetes study and 171 normal controls. Results Body size and blood pressure were not correlated to lipids and glycemic control. OR (99% CI for high-LDL were 2.07 (1.21-3.54 and 2.51 (1.46-4.31, in the 4th and 5th HbA1c quintiles, respectively. Hypertriglyceridemia increased in the 5th quintile of HbA1c, OR 2.76 (1.20-6.37. OR of low-HDL-cholesterol were 0.48 (0.24-0.98 and 0.41 (0.19-0.85 in the 3rd and 4th HbA1c quintiles, respectively. HDL-cholesterol correlated positively (0.437 with HbA1c in the 3rd quintile. HDL-cholesterol and insulin dose correlated inversely in all levels of glycemic control. Conclusions Correlation of serum lipids with HbA1c is heterogeneous across the spectrum of glycemic control in type 1 diabetes individuals. LDL-cholesterol and triglycerides worsened alongside HbA1c with distinct thresholds. Association of lower HDL-cholesterol with higher daily insulin dose is consistent and it points out to a role of exogenous hyperinsulinemia in the pathophysiology of the CVRF clustering. These data suggest diverse pathophysiological processes depending on HbA1c, refuting a unified explanation for cardiovascular risk in type 1

  14. Enhancing Effect of Hydroxyurea on Hb F in Sickle Cell Disease: Ten-Year Egyptian Experience.

    Science.gov (United States)

    Youssry, Ilham; Abdel-Salam, Amina; Ismail, Rania; Bou-Fakhredin, Rayan; Mohamed Samy, Rania; Ezz El-Deen, Fatma; Taher, Ali T

    Patients with sickle cell disease experience hemolytic anemia and vaso-occlusions that result in pain, organ injury, and premature mortality. Several prospective studies have verified the efficacy and tolerability of hydroxyurea (HU), and demonstrated its efficacy in reducing painful vaso-occlusive crises (VOCs) in addition to its ability to increase Hb F levels. We aimed to evaluate the long-term effects of HU therapy on Hb F and assess its long term efficacy and safety in sickle cell disease patients. A retrospective study on 60 sickle cell disease patients was conducted. We studied the laboratory changes, frequency of VOCs per year, frequency of hospital admisions per year and number of transfusions per year, both before and after HU therapy. The follow-up period was 4 to 120 months. Hb F levels after HU therapy positively correlated with the duration of HU therapy, baseline Hb F levels and baseline total hemoglobin (Hb) (r = 0.4, p = 0.04; r = 0.45, p = 0.001; r = 0.5, p = 0.019, respectively) and inversely correlated with baseline total leucocyte count (r = -0.33, p = 0.034). Hydroxyurea therapy was associated with an increase in the total Hb and mean corpuscular volume (MCV) (p = 0.009, p = 0.000; respectively) and with a decrease in total leucocyte count, platelet count and reticulocyte count (p = 0.00, p = 0.03, p = 0.02, respectively). Moreover, a significant reduction in the frequency of VOCs, transfusion frequency and hospital admissions per year after HU therapy was shown in the studied subjects. Hydroxyurea induced an increase in Hb F level, which was maintained over time and was associated with clinical efficacy and acceptable safety.

  15. Decommissioning high-level waste surface facilities

    International Nuclear Information System (INIS)

    1978-04-01

    The protective storage, entombment and dismantlement options of decommissioning a High-Level Waste Surface Facility (HLWSF) was investigated. A reference conceptual design for the facility was developed based on the designs of similar facilities. State-of-the-art decommissioning technologies were identified. Program plans and cost estimates for decommissioning the reference conceptual designs were developed. Good engineering design concepts were on the basis of this work identified

  16. Stress analysis of the HFIR HB-2 and HB-3 beam tube nozzles

    International Nuclear Information System (INIS)

    Williams, P.T.

    1998-08-01

    The results of three-dimensional linear elastic stress analyses of the HFIR HB-2 and HB-3 nozzles are presented in this report. Finite element models were developed using the PATRAN pre-processing code and translated into ABAQUS input file format. A scoping analysis using simple geometries with internal pressure loading was carried out to assess the capabilities of the ABAQUS/Standard code to calculate maximum principal stress distributions within cylinders with and without holes. These scoping calculations were also used to provide estimates for the variation in tangential stress around the rim of a nozzle using the superposition of published closed-form solutions for the stress around a hole in an infinite flat plate under uniaxial tension. From the results of the detailed finite element models, peak stress concentration factors (based on the maximum principal stresses in tension) were calculated to be 3.0 for the HB-2 nozzle and 2.8 for the HB-3 nozzle. Submodels for each nozzle were built to calculate the maximum principal stress distribution in the weldment region around the nozzle, where displacement boundary conditions for the submodels were automatically calculated by ABAQUS using the results of the global nozzle models. Maximum principal stresses are plotted and tabulated for eight positions around each nozzle and nozzle weldment

  17. International Mapping of Antenna-Measurement Facilities

    DEFF Research Database (Denmark)

    Boccia, Luigi; Breinbjerg, Olav; Di Massa, Giuseppe

    2006-01-01

    This paper presents a comprehensive international mapping of antenna-measurement facilities. This initiative, conducted within the framework of the Antenna Centre of Excellence (ACE) of the European Union, is oriented toward all institutions having research, development, or operational activities...... measurements, in particular from the wireless communication industry, to identify and contact antenna-measurement facilities. The first phase of the mapping showed a significant and encouraging reaction to this initiative, with more than 50 European facilities currently registered. The next phase aims...

  18. Determining the Threshold for HbA1c as a Predictor for Adverse Outcomes After Total Joint Arthroplasty: A Multicenter, Retrospective Study.

    Science.gov (United States)

    Tarabichi, Majd; Shohat, Noam; Kheir, Michael M; Adelani, Muyibat; Brigati, David; Kearns, Sean M; Patel, Pankajkumar; Clohisy, John C; Higuera, Carlos A; Levine, Brett R; Schwarzkopf, Ran; Parvizi, Javad; Jiranek, William A

    2017-09-01

    Although HbA1c is commonly used for assessing glycemic control before surgery, there is no consensus regarding its role and the appropriate threshold in predicting adverse outcomes. This study was designed to evaluate the potential link between HbA1c and subsequent periprosthetic joint infection (PJI), with the intention of determining the optimal threshold for HbA1c. This is a multicenter retrospective study, which identified 1645 diabetic patients who underwent primary total joint arthroplasty (1004 knees and 641 hips) between 2001 and 2015. All patients had an HbA1c measured within 3 months of surgery. The primary outcome of interest was a PJI at 1 year based on the Musculoskeletal Infection Society criteria. Secondary outcomes included orthopedic (wound and mechanical complications) and nonorthopedic complications (sepsis, thromboembolism, genitourinary, and cardiovascular complications). A regression analysis was performed to determine the independent influence of HbA1c for predicting PJI. Overall 22 cases of PJI occurred at 1 year (1.3%). HbA1c at a threshold of 7.7 was distinct for predicting PJI (area under the curve, 0.65; 95% confidence interval, 0.51-0.78). Using this threshold, PJI rates increased from 0.8% (11 of 1441) to 5.4% (11 of 204). In the stepwise logistic regression analysis, PJI remained the only variable associated with higher HbA1c (odds ratio, 1.5; confidence interval, 1.2-2.0; P = .0001). There was no association between high HbA1c levels and other complications assessed. High HbA1c levels are associated with an increased risk for PJI. A threshold of 7.7% seems to be more indicative of infection than the commonly used 7% and should perhaps be the goal in preoperative patient optimization. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Coinheritance of High Oxygen Affinity Hb Helsinki [HBB: c.248A>T; β82(EF6)Lys→Met] with Hb H Disease.

    Science.gov (United States)

    Lee, Shir-Ying; Goh, Jia-Hui; Tan, Karen M L; Liu, Te-Chih

    2017-05-01

    Hb Helsinki [HBB: c.248A>T; β82(EF6)Lys→Met] is a high oxygen affinity hemoglobin (Hb) causing polycythemia, whereas Hb H (β4) disease causes mild to severe chronic hemolytic anemia. The clinical characteristics, gel electrophoresis, capillary electrophoresis (CE) and molecular genotyping of a case of Hb Helsinki coinherited with Hb H disease in an ethnic Malay is described, illustrating the interaction between the β-globin variant and coinheritance of three α gene deletions. The proband was asymptomatic, exhibited microcytosis and a normal with Hb value.

  20. Evaluation of the effect of self-care education based on VARK learning style on HbA1c and FBS levels in patients with type II diabetes

    Directory of Open Access Journals (Sweden)

    Amir Reza Saleh Moghadam

    2016-02-01

    Full Text Available Background: Patients with type II diabetes mostly struggle with increased fasting blood sugar (FBS and glycosylated hemoglobin HbA1c, which are associated with irrecoverable complications. Self-care education and different types of learning among patients are regarded as some of the most important issues in this regard. Therefore, this study aimed to evaluate the effect of self-care education based on VARK learning style on HbA1c and FBS in patients with type II diabetes. Methods: This clinical trial was conducted on patients with type II diabetes referring to Parsian Clinic in Mashhad, Iran in 2015. In total, 72 samples were selected through randomized convenience sampling and divided into two control and intervention groups of 36 cases. Subjects of the intervention group were also divided into subgroups of visual, aural, read/write and kinesthetic based on the results of VARK questionnaire. Self-care education was carried out for the intervention group in two 60-minute sessions once every two weeks, tailored to learning styles of the patients. Meanwhile, routine conferences were held for the control group. HbA1c and FBS levels were evaluated in all the participants before and a month and a half after the intervention to assess the self-care of patients. Data analysis was performed in SPSS version 21 using Mann-Whitney U, Chi-square, independent t-test and Wilcoxon signed-rank test. Results: In this study, mean score of HbA1c level was decreased from 7.7±0.8 to 7.0±5.7 (P<0.062, whereas mean score of FBS level was alleviated from 176.1±33.5 to 147.7±32.8 (P<0.001, which was only significant regarding the level of FBS (P=0.002. Conclusion: According to the results of this study, application of VARK learning style led to a reduction in HbA1c and FBS levels, contributing to improved self-care in patients with type II diabetes. Therefore, it is suggested that learning style of patients be determined using VARK questionnaire before their

  1. Characterization of a Novel Anti-Human HB-EGF Monoclonal Antibody Applicable for Paraffin-Embedded Tissues and Diagnosis of HB-EGF-Related Cancers.

    Science.gov (United States)

    Iwamoto, Ryo; Takagi, Mika; Akatsuka, Jun-Ichi; Ono, Ken-Ichiro; Kishi, Yoshiro; Mekada, Eisuke

    2016-04-01

    Heparin-binding EGF-like growth factor (HB-EGF) is a member of the EGF family of growth factors that bind to and activate the EGF receptor (EGFR/ErbB1) and ErbB4. HB-EGF plays pivotal roles in pathophysiological processes, including cancer. Thus, monoclonal antibodies (mAbs) for HB-EGF detection could be an important tool in the therapeutic diagnosis of HB-EGF-related cancers and other diseases. However, few mAbs, especially those applicable for immunohistochemistry (IHC), have been established to date. In this study, we generated a clone of hybridoma-derived mAb 2-108 by immunizing mice with recombinant human HB-EGF protein expressed by human cells. The mAb 2-108 specifically bound to human HB-EGF but not to mouse HB-EGF and was successful in immunoblotting, even under reducing conditions, immunoprecipitation, and immunofluorescence for unfixed as well as paraformaldehyde-fixed cells. Notably, this mAb was effective in IHC of paraffin-embedded tumor specimens. Epitope mapping analysis showed that mAb 2-108 recognized the N-terminal prodomain in HB-EGF. These results indicate that this new anti-HB-EGF mAb 2-108 would be useful in the diagnosis of HB-EGF-related cancers and would be a strong tool in both basic and clinical research on HB-EGF.

  2. Elevated Hb A₂ Levels in a Patient with a Compound Heterozygosity for the (β⁺) -31 (A > G) and (β⁰) Codon 17 (A > T) Mutations Together with a Single α-Globin Gene.

    Science.gov (United States)

    Panyasai, Sitthichai; Jaiping, Kanokwan; Pornprasert, Sakorn

    2015-01-01

    We report the molecular and hematological feature of a Thai woman who had clinical diagnosis of β-thalassemia intermedia (β-TI). Hemoglobin (Hb) high performance liquid chromatography (HPLC) analysis identified Hb A (64.4%), Hb F (12.3%) and Hb A2/E (15.9%) with small peaks of Hb Bart's (γ4) and Hb H (β4). She was initially diagnosed as EA Bart's disease, which occurs from combination of Hb H disease and Hb E (HBB: c.79G > A) trait. However, the Hb analysis using capillary electrophoresis (CE) demonstrated no Hb E, 68.5% Hb A, 15.5% Hb F and 16.0% Hb A2. DNA analysis showed a compound heterozygosity for (β(+)) -31 (A > G) (HBB: c.-81A > G) and (β(0)) codon 17 (A > T) (HBB: c.52A > T) mutations and deletional Hb H (- -(SEA)/-α(3.7)). Thus, she was finally diagnosed with a combination of Hb H disease and compound heterozygosity of β(+)/β(0)-thalassemia (β(+)/β(0)-thal). The β-globin mutations could affect not only hematological parameters but also elevate the Hb A2 levels. These effects could not be ameliorated by the coinheritance of Hb H disease. Therefore, a better understanding of the effects of this combination on hematological analysis data will be useful for providing accurate diagnosis, genetic counseling, prevention and control programs of β-thalassemia major (β-TM).

  3. The immunogenicity and safety of the new, Indonesian DTwP-HB-Hib vaccine compared to the DTwP/HB vaccine given with the Hib vaccine

    Directory of Open Access Journals (Sweden)

    Novilia Sjafri Bachtiar

    2017-06-01

    Full Text Available Background Haemophilus influenzae type b (Hib causes infection with predominant manifestations of pneumonia, meningitis, and other invasive diseases, occurring primarily in children aged under 2 years, particularly in infants.  The World Health Organization (WHO and Indonesian Technical Advisory Group for Immunization recommend to include the Hib vaccine into the national immunization program. The newly developed DTwP-HB-Hib combination vaccine is anticipated to be the preferred choice for Hib vaccine introduction; it is efficient, simple, and has higher coverage. Objective To evaluate the immunogenicity and safety of a new, combined Bio Farma DTwP-HB-Hib vaccine, compared to the registered Hib monovalent vaccine given simultaneously with the local DTwP-HB vaccine, when used as the primary vaccination of Indonesian infants. Methods A prospective, randomized, open-label, phase II study was conducted on the DTwP-HB-Hib vaccine compared to the Hib (registered vaccine given simultaneously with the DTwP-HB vaccine, in Bandung from July 2011 to January 2012. Infants were serially vaccinated at 6-11, 10-15, and 14-19 weeks. Serological assessments were done prior to the first vaccine dose and 28 days after the third dose. Safety was assessed from the time of first injection until 1 month after the last injection. Results Of 220 healthy infants enrolled, 211 completed the study, with 105 receiving the combined vaccine and 106 the two separate vaccines. All vaccines were well tolerated. No differences in rates of local and systemic reactions were seen between the two methods of administration. No serious adverse events were considered to be related to the vaccines. In the DTwP-HB-Hib primary-vaccination group, at least 98% of the infants reached protective levels of antibodies (seropositivity against the antigens employed in the vaccines while 96% in the control group. Conclusion The DTwP-HB-Hib combined vaccine is immunogenic and safe, as well as

  4. Treatment intensification without improved HbA1c levels in children and adolescents with Type 1 diabetes mellitus.

    Science.gov (United States)

    Sildorf, S M; Hertel, N T; Thomsen, J; Fredheim, S; Hastrup, H; Pipper, C; Hertz, B; Svensson, J

    2016-04-01

    To examine trends in diabetes treatment in Danish children and adolescents with Type 1 diabetes mellitus, comparing treatment intensity with metabolic outcomes in the population, and to describe the challenges of population-based registries in a clinical setting with rapidly changing treatment methods. This observational study is based on the Danish national population registry of childhood diabetes, which includes 99% of children diagnosed with Type 1 diabetes before the age of 15 years. We included 4527 people diagnosed between 2000 and 2012. Self-monitored blood glucose measurements, insulin injections/boluses, treatment method and metabolic control quantifications were analysed and adjusted for the effects of gender and ethnicity, the combined effect of age, visit year and duration, and for the random effects of individual and hospital settings. Treatment was intensified via an increasing number of self-monitored blood glucose measurements and injections/boluses. More than six injections/boluses and an increased number of self-monitored blood glucose measurements were significantly associated with lower metabolic control. No reduction, however, in the overall mean HbA1c concentration was observed between 2005 [66 mmol/mol (8.2%)] and 2012 [65 mmol/mol (8.1%)]. Changed registration practices in 2009 introduced artificial jumps in data. Intensifying treatment alone does not lead to improved metabolic control in the overall population despite the appearance of lower HbA1c in individuals with a greater number of self-monitored blood glucose measurements and injections/boluses. The contradictory results reflect difficulties in using observational studies to predict results of intervention in the individual. Data collected from population-based registries need to be adjusted continuously to reflect changes in care. © 2015 Diabetes UK.

  5. Discordance in the diagnosis of diabetes: Comparison between HbA1c and fasting plasma glucose.

    Science.gov (United States)

    Ho-Pham, Lan T; Nguyen, Uyen D T; Tran, Truong X; Nguyen, Tuan V

    2017-01-01

    HbA1c has been introduced as a complementary diagnostic test for diabetes, but its impact on disease prevalence is unknown. This study evaluated the concordance between HbA1c and fasting plasma glucose (FPG) in the diagnosis of diabetes in the general population. The study was designed as a population based investigation, with participants being sampled from the Ho Chi Minh City, Vietnam. Blood samples were collected after overnight fasting and analyzed within 4 hours after collection. HbA1c was measured with high pressure liquid chromatography (Arkray Adams, Japan). FPG was measured by the hexokinase method (Advia Autoanalyzer; Bayer Diagnostics, Germany). Diabetes was defined as HbA1c ≥ 6.5% or FPG ≥ 7.0 mmol/L. Prediabetes was classified as HbA1c between 5.7% and 6.4%. The study included 3523 individuals (2356 women) aged 30 years and above. Based on the HbA1c test, the prevalence of diabetes and prediabetes was 9.7% (95%CI, 8.7-10.7%; n = 342) and 34.6% (33.0-36.2; n = 1219), respectively. Based on the FPG test, the prevalence of diabetes and prediabetes was 6.3% (95%CI, 5.5-7.2%; n = 223) and 12.1% (11.1-13.2; n = 427). Among the 427 individuals identified by FPG as "pre-diabetes", 28.6% were classified as diabetes by HbA1c test. The weighted kappa statistic of concordance between HbA1c and FPG was 0.55, with most of the discordance being in the prediabetes group. These data indicate that there is a significant discordance in the diagnosis of diabetes between FPG and HbA1c measurements, and the discordance could have significant impact on clinical practice. FPG appears to underestimate the burden of undiagnosed diabetes.

  6. High-Level Waste Vitrification Facility Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    D. A. Lopez

    1999-08-01

    A ''Settlement Agreement'' between the Department of Energy and the State of Idaho mandates that all radioactive high-level waste now stored at the Idaho Nuclear Technology and Engineering Center will be treated so that it is ready to be moved out of Idaho for disposal by a compliance date of 2035. This report investigates vitrification treatment of the high-level waste in a High-Level Waste Vitrification Facility based on the assumption that no more New Waste Calcining Facility campaigns will be conducted after June 2000. Under this option, the sodium-bearing waste remaining in the Idaho Nuclear Technology and Engineering Center Tank Farm, and newly generated liquid waste produced between now and the start of 2013, will be processed using a different option, such as a Cesium Ion Exchange Facility. The cesium-saturated waste from this other option will be sent to the Calcine Solids Storage Facilities to be mixed with existing calcine. The calcine and cesium-saturated waste will be processed in the High-Level Waste Vitrification Facility by the end of calendar year 2035. In addition, the High-Level Waste Vitrification Facility will process all newly-generated liquid waste produced between 2013 and the end of 2035. Vitrification of this waste is an acceptable treatment method for complying with the Settlement Agreement. This method involves vitrifying the waste and pouring it into stainless-steel canisters that will be ready for shipment out of Idaho to a disposal facility by 2035. These canisters will be stored at the Idaho National Engineering and Environmental Laboratory until they are sent to a national geologic repository. The operating period for vitrification treatment will be from the end of 2015 through 2035.

  7. High-Level Waste Vitrification Facility Feasibility Study

    International Nuclear Information System (INIS)

    D. A. Lopez

    1999-01-01

    A ''Settlement Agreement'' between the Department of Energy and the State of Idaho mandates that all radioactive high-level waste now stored at the Idaho Nuclear Technology and Engineering Center will be treated so that it is ready to be moved out of Idaho for disposal by a compliance date of 2035. This report investigates vitrification treatment of the high-level waste in a High-Level Waste Vitrification Facility based on the assumption that no more New Waste Calcining Facility campaigns will be conducted after June 2000. Under this option, the sodium-bearing waste remaining in the Idaho Nuclear Technology and Engineering Center Tank Farm, and newly generated liquid waste produced between now and the start of 2013, will be processed using a different option, such as a Cesium Ion Exchange Facility. The cesium-saturated waste from this other option will be sent to the Calcine Solids Storage Facilities to be mixed with existing calcine. The calcine and cesium-saturated waste will be processed in the High-Level Waste Vitrification Facility by the end of calendar year 2035. In addition, the High-Level Waste Vitrification Facility will process all newly-generated liquid waste produced between 2013 and the end of 2035. Vitrification of this waste is an acceptable treatment method for complying with the Settlement Agreement. This method involves vitrifying the waste and pouring it into stainless-steel canisters that will be ready for shipment out of Idaho to a disposal facility by 2035. These canisters will be stored at the Idaho National Engineering and Environmental Laboratory until they are sent to a national geologic repository. The operating period for vitrification treatment will be from the end of 2015 through 2035

  8. Effect of Long-Term Dietary Arginyl-Fructose (AF on Hyperglycemia and HbA1c in Diabetic db/db Mice

    Directory of Open Access Journals (Sweden)

    Kwang-Hyoung Lee

    2014-05-01

    Full Text Available We have previously reported that Amadori compounds exert anti-diabetic effects by lowering sucrose-induced hyperglycemia in normal Sprague-Dawley rats. In the present study we extended our recent findings to evaluate whether α-glucosidase inhibitor arginyl-fructose (AF lowers blood glucose level in diabetic db/db mice, a genetic model for type 2 diabetes. The db/db mice were randomly assigned to high-carbohydrate diets (66.1% corn starch with and without AF (4% in the diet for 6 weeks. Changes in body weight, blood glucose level, and food intake were measured daily for 42 days. Dietary supplementation of AF resulted in a significant decrease of blood glucose level (p < 0.001 and body weight (p < 0.001. The level of HbA1c, a better indicator of plasma glucose concentration over prolonged periods of time, was also significantly decreased for 6-week period (p < 0.001. Dietary treatment of acarbose® (0.04% in diet, a positive control, also significantly alleviated the level of blood glucose, HbA1c, and body weight. These results indicate that AF Maillard reaction product improves postprandial hyperglycemia by suppressing glucose absorption as well as decreasing HbA1c level.

  9. Hb Tianshui (HBB: C.119A > G) in Compound Heterozygosity with Hb S (HBB: C.20A > T) from Odisha, India.

    Science.gov (United States)

    Meher, Satyabrata; Dehury, Snehadhini; Mohanty, Pradeep Kumar; Patel, Siris; Pattanayak, Chinmayee; Bhattacharya, Subhra; Das, Kishalaya; Sarkar, Biswanath

    2016-08-01

    We describe here a rare β-globin gene variant, Hb Tianshui [β39(C5)Glu→Arg; HBB: c.119A > G], detected during routine screening in Odisha, India. This is the second report of Hb Tianshui and the first to describe the cation exchange high performance liquid chromatography (HPLC) and DNA studies of two cases of this variant. Both cases had coinherited Hb S (HBB: c.20A > T) but none presented with typical symptoms of sickle cell disease. One of the cases was heterozygous for a common α-thalassemia (α-thal) allele (-α(3.7)) (rightward) (NG_000006.1: g.34164_37967del3804) and marginally raised Hb F percentage, while the other Hb S/Hb Tianshui case was completely benign and healthy. An atypical Asian Indian haplotype [+ - + - +] could be assigned to the Hb Tianshui variant. Hb Tianshui seems to mimic a few other Hb variants in cation exchange HPLC. However, we report two specific patterns in the chromatograms that are characteristic to Hb Tianshui. Combining an alkaline electrophoresis result with cation exchange HPLC at screening would be preferred to detect this rare variant, especially in regions with considerable frequency of Hb E [β26(B8)Glu→Lys; HBB: c.79G > A] or Hb S.

  10. Thermo-mechanical model optimization of HB-LED packaging

    NARCIS (Netherlands)

    Yuan, C.A.; Erinc, M.; Gielen, A.W.J.; Waal, A. van der; Driel, W. van; Zhang, K.

    2011-01-01

    Lighting is an advancing phenomenon both on the technology and on the market level due to the rapid development of the solid state lighting technology. The efforts in improving the efficacy of high brightness LED's (HB-LED) have concentrated on the packaging architecture. Packaging plays a

  11. Initial tank calibration at NUCEF critical facility. 1. Measurement procedure and its result

    International Nuclear Information System (INIS)

    Yanagisawa, Hiroshi; Mineo, Hideaki; Tonoike, Kotaro; Takeshita, Isao; Hoshi, Katsuya; Hagiwara, Hiroyuki.

    1994-07-01

    Initial tank calibrations were carried out prior to hot operation of critical facilities in NUCEF: Nuclear Fuel Cycle Safety Engineering Research Facility, for the purpose of the nuclear material accountancy and control for the facility. Raw calibration data were collected from single run per one tank by measuring differential pressure with dip-tube systems, weight of calibration liquid (demineralized water) poured into the tank, temperature in the tank and so on, without operation of tank ventilation system. Volume and level data were obtained by applying density and buoyancy corrections to the raw data. As a result, the evaluated measurement errors of volume and level were small enough, e.g. within 0.2 lit. and 1.0 mm, respectively, for Pu accountancy tanks. This paper summarizes the above-mentioned measurement procedures, collected data, data correction procedures and evaluated measurement errors. (author)

  12. Changes in proHB-EGF expression after functional activation of the immune system cells

    Directory of Open Access Journals (Sweden)

    T. O. Chudina

    2017-12-01

    Full Text Available The level of proHB-EGF expression on J774, Raji, KG-1 cells derived from different types of human and mouse immune system cells under the standard in vitro culture conditions and during functional activation of these cells was investigated. Changes in the proHB-EGF expression on the cell surface were found to depend on the density of cell population, the content of fetal bovine serum in the culture medium, the effect of mitogenic factors – bacterial lipopolysaccharide, an inactive full-size form of diphtheria toxin (CRM197 and recombinant soluble HB-EGF – rsHB-EGF. The results obtained are important for the understanding of the functional role of proHB-EGF receptor on the surface of macrophage-like cells and B lymphocytes and indicate the involvement of this receptor in immune response regulation in an organism.

  13. 76 FR 66333 - Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental...

    Science.gov (United States)

    2011-10-26

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2011-0247] Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental Assessment and Finding of No Significant... Facility Operating License No. DPR-23, issued to Carolina Power & Light Company (the licensee), for...

  14. Simultaneous dual syringe electrospinning system using benign solvent to fabricate nanofibrous P(3HB-co-4HB)/collagen peptides construct as potential leave-on wound dressing

    International Nuclear Information System (INIS)

    Vigneswari, S.; Murugaiyah, V.; Kaur, G.; Abdul Khalil, H.P.S.; Amirul, A.A.

    2016-01-01

    The main focus of this study is the incorporation of collagen peptides to fabricate P(3-hydroxybutyrate-co-4-hydroxybutyrate) [P(3HB-co-4HB)] nano-fiber construct to further enhance surface wettability and support cell growth while harbouring desired properties for biodegradable wound dressing. Simultaneous electrospinning of nanofiber P(3HB-co-4HB)/collagen peptides construct was carried out using dual syringe system. The wettability of the constructs increased with the increase in 4HB molar fraction from 20 mol% 4HB [53.2°], P(3HB-co-35 mol%4HB)[48.9°], P(3HB-co-50 mol%4HB)[44.5°] and P(3HB-co-82 mol%4HB) [37.7°]. In vitro study carried out using mouse fibroblast cells (L929) grown on nanofiber P(3HB-co-4HB)/collagen peptides construct showed an increase in cell proliferation. In vivo study using animal model (Sprague Dawley rats) showed that nanofibrous P(3HB-co-4HB)/collagen peptides construct had a significant effect on wound contractions with the highest percentage of wound closure of 79%. Hence, P(3HB-co-4HB)/collagen peptides construct suitable for wound dressing have been developed using nano-fabrication technique. - Highlights: • Nano-fiber construct to enhance surface wettability and cell growth, harbouring desired properties as biodegradable wound dressing. • Simultaneous electrospinning of nanofiber P(3HB-co-4HB)/collagen construct using dual syringe system. • Nanofibrous construct accelerated wound healing with efficient cellular organization.

  15. Simultaneous dual syringe electrospinning system using benign solvent to fabricate nanofibrous P(3HB-co-4HB)/collagen peptides construct as potential leave-on wound dressing

    Energy Technology Data Exchange (ETDEWEB)

    Vigneswari, S. [Malaysian Institute of Pharmaceuticals and Nutraceuticals, NIBM, MOSTI, 11700 Penang (Malaysia); Institute of Marine Biotechnology, Universiti Malaysia Terengganu, 21030 Kuala Terengganu (Malaysia); Murugaiyah, V. [School of Pharmaceutical Sciences, Universiti Sains Malaysia, 11700 Penang (Malaysia); Kaur, G. [Institute of Research in Molecular Medicine, Universiti Sains Malaysia, 11700 Penang (Malaysia); Abdul Khalil, H.P.S. [School of Industrial Technology, Universiti Sains Malaysia, 11700 Penang (Malaysia); Amirul, A.A., E-mail: amirul@usm.my [Malaysian Institute of Pharmaceuticals and Nutraceuticals, NIBM, MOSTI, 11700 Penang (Malaysia); School of Biological Sciences, Universiti Sains Malaysia, 11800 Penang (Malaysia); Centre of Chemical Biology, Universiti Sains Malaysia, 11900 Penang (Malaysia)

    2016-09-01

    The main focus of this study is the incorporation of collagen peptides to fabricate P(3-hydroxybutyrate-co-4-hydroxybutyrate) [P(3HB-co-4HB)] nano-fiber construct to further enhance surface wettability and support cell growth while harbouring desired properties for biodegradable wound dressing. Simultaneous electrospinning of nanofiber P(3HB-co-4HB)/collagen peptides construct was carried out using dual syringe system. The wettability of the constructs increased with the increase in 4HB molar fraction from 20 mol% 4HB [53.2°], P(3HB-co-35 mol%4HB)[48.9°], P(3HB-co-50 mol%4HB)[44.5°] and P(3HB-co-82 mol%4HB) [37.7°]. In vitro study carried out using mouse fibroblast cells (L929) grown on nanofiber P(3HB-co-4HB)/collagen peptides construct showed an increase in cell proliferation. In vivo study using animal model (Sprague Dawley rats) showed that nanofibrous P(3HB-co-4HB)/collagen peptides construct had a significant effect on wound contractions with the highest percentage of wound closure of 79%. Hence, P(3HB-co-4HB)/collagen peptides construct suitable for wound dressing have been developed using nano-fabrication technique. - Highlights: • Nano-fiber construct to enhance surface wettability and cell growth, harbouring desired properties as biodegradable wound dressing. • Simultaneous electrospinning of nanofiber P(3HB-co-4HB)/collagen construct using dual syringe system. • Nanofibrous construct accelerated wound healing with efficient cellular organization.

  16. HbA1c, systolic blood pressure variability and diabetic retinopathy in Asian type 2 diabetics.

    Science.gov (United States)

    Foo, Valencia; Quah, Joanne; Cheung, Gemmy; Tan, Ngiap Chun; Ma Zar, Kyi Lin; Chan, Choi Mun; Lamoureux, Ecosse; Tien Yin, Wong; Tan, Gavin; Sabanayagam, Charumathi

    2017-02-01

    The aim of the present study was to examine the association between variability in HbA1c or systolic blood pressure (SBP) and diabetes-specific moderate retinopathy in Asians with type 2 diabetes (T2D). A retrospective study was conducted of 172 cases of moderate diabetic retinopathy (DR) cases and 226 controls without DR, matched for age, sex, and ethnicity. Serial HbA1c and SBP (range 3-6 readings) over the 2 years prior to photographic screening of DR were collected. Intrapersonal mean and SD values for HbA1c (iM-HbA1c and iSD-HbA1c) and SBP (iM-SBP and iSD-SBP) were derived. Moderate DR was assessed from digital retinal photographs and defined as levels >43 using the Early Treatment Diabetic Retinopathy Study scale. Cases of moderate DR had higher iM-HbA1c (8.2 % vs 7.3 %; P = 0.001), iSD-HbA1c (1.22 vs 0.64; P = 0.001), iM-SBP (136.8 vs 129.6 mmHg; P = 0.001) and iSD-SBP (13.3 vs 11.1; P = 0.002) than controls. In the multivariate regression model adjusted for age, gender, ethnicity, duration of diabetes, SBP, and HbA1c, iM-HbA1c and iM-SBP were significantly associated with moderate DR (odds ratio [OR] 1.80, 95 % confidence interval [CI] 1.37-2.36; and OR 1.03, 95 % CI 1.01-1.05, respectively). Neither iSD-HbA1c nor iSD-SBP were associated with moderate DR. When stratified by HbA1c HbA1c levels and SBP, but not their variability, were associated with moderate DR. Among those with good glycemic control, wider variability of SBP is associated with moderate DR. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  17. Modifying effects of maternal Hb concentration on infant birth weight in women receiving prenatal iron-containing supplements: a randomised controlled trial.

    Science.gov (United States)

    Wang, Linlin; Mei, Zuguo; Li, Hongtian; Zhang, Yali; Liu, Jianmeng; Serdula, Mary K

    2016-02-28

    Concerns have been raised about the benefits of Fe-containing supplements on infant birth weight among women with normal/high Hb levels at baseline. Thus far, no clinical trials have examined whether the effects of prenatal Fe-containing supplements on birth weight vary by maternal Hb levels. We compared the effects of Fe-folic acid (IFA) or multiple micronutrients (MMN) with folic acid (FA) supplements on birth weight among pregnant women with mild/no anaemia or high Hb levels. A double-blind randomised controlled trial was conducted in 2006-2009. In total, 18 775 pregnant women with mild/no anaemia (145 g/l) baseline Hb levels, IFA and MMN supplements increased birth weight by 91·44 (95% CI 3·37, 179·51) g and 107·63 (95% CI 21·98, 193·28) g (PHb concentration. In conclusion, the effects of Fe-containing supplements on birth weight depended on baseline Hb concentrations. The Fe-containing supplements improved birth weight in women with very high Hb levels before 20 weeks of gestation.

  18. HbA1c for diagnosis and prognosis of gestational diabetes mellitus.

    Science.gov (United States)

    Kwon, Soon Sung; Kwon, Ja-Young; Park, Yong-Won; Kim, Young-Han; Lim, Jong-Baeck

    2015-10-01

    HbA1c is a widely used marker in diagnosing type 2 diabetes mellitus (DM), but its clinical utility in diagnosing gestational diabetes mellitus (GDM) is not established. Here, we evaluated the clinical usefulness of HbA1c in diagnosing GDM and predicting the risk of future type 2 DM development among GDM patients. This retrospective, cross-sectional study included 321 subjects who underwent 100-g oral glucose tolerance tests (OGTT) during pregnancy. HbA1c and other variables were analyzed to evaluate their diagnostic performance for GDM. To evaluate the clinical usefulness of HbA1c in predicting future type 2 DM development, we classified GDM subjects who had more than 3 months of follow-up data into two subgroups: those who developed postpartum type 2 DM (PDM) and those who did not. HbA1c was significantly higher in the GDM group than in the normal control group. With the 100-g OGTT as reference, HbA1c showed 91.3% sensitivity and 62% specificity at a cut-off value of 5.05% (32 mmol/mol) for GDM diagnosis. At a cut-off value of 5.25% (34 mmol/mol), sensitivity was 73.6% and specificity was 77.2%. HbA1c levels during pregnancy were higher in those with PDM than in those without PDM (5.91 [41 mmol/mol] vs. 5.44% [36 mmol/mol], p<0.001). The prognostic value of HbA1c for PDM was evaluated by ROC curve analysis, with sensitivity of 78.6% and specificity of 72.5% at a cut-off value of 5.55% (37 mmol/mol). HbA1c showed high sensitivity with relatively low specificity for diagnosis of GDM in pregnant women and was a potential predictor of PDM. HbA1c may be able to be used as a simple and less invasive alternative screening test for OGTT in GDM patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. α-Thalassemia Associated with Hb Instability: A Tale of Two Features. The Case of Hb Rogliano or α1 Cod 108(G15)Thr→Asn and Hb Policoro or α2 Cod 124(H7)Ser→Pro.

    Science.gov (United States)

    Musollino, Gennaro; Cardiero, Giovanna; Flagiello, Angela; La Porta, Gaetana; Lagona, Laura; Prezioso, Romeo; Qualtieri, Gabriele; Gaudiano, Carlo; Medulla, Emilia; Merlino, Antonello; Pucci, Piero; Lacerra, Giuseppina

    2015-01-01

    We identified two new variants in the third exon of the α-globin gene in families from southern Italy: the Hb Rogliano, α1 cod108 ACC>AAC or α1[α108(G15)Thr→Asn] and the Hb Policoro, α2 cod124 TCC>CCC or α2[α124(H7)Ser→Pro]. The carriers showed mild α-thalassemia phenotype and abnormal hemoglobin stability features. These mutations occurred in the G and H helices of the α-globin both involved in the specific recognition of AHSP and β1 chain. Molecular characterization of mRNA, globin chain analyses and molecular modelling studies were carried out to highlight the mechanisms causing the α-thalassemia phenotype. The results demonstrated that the α-thalassemia defect associated with the two Hb variants originated by different defects. Hb Rogliano showed an intrinsic instability of the tetramer due to anomalous intra- and inter-chain interactions suggesting that the variant chain is normally synthesized and complexed with AHSP but rapidly degraded because it is unable to form the α1β1 dimers. On the contrary in the case of Hb Policoro two different molecular mechanisms were shown: the reduction of the variant mRNA level by an unclear mechanism and the protein instability due to impairment of AHSP interaction. These data highlighted that multiple approaches, including mRNA quantification, are needed to properly identify the mechanisms leading to the α-thalassemia defect. Elucidation of the specific mechanism leads to the definition of a given phenotype providing important guidance for the diagnosis of unstable variants. PMID:25730315

  20. Serum Heparin-binding Epidermal Growth Factor-like Growth Factor (HB-EGF) as a Biomarker for Primary Ovarian Cancer.

    Science.gov (United States)

    Miyata, Kohei; Yotsumoto, Fusanori; Fukagawa, Satoshi; Kiyoshima, Chihiro; Ouk, Nam Sung; Urushiyama, Daichi; Ito, Tomohiro; Katsuda, Takahiro; Kurakazu, Masamitsu; Araki, Ryota; Sanui, Ayako; Miyahara, Daisuke; Murata, Masaharu; Shirota, Kyoko; Yagi, Hiroshi; Takono, Tadao; Kato, Kiyoko; Yaegashi, Nobuo; Akazawa, Kohei; Kuroki, Masahide; Yasunaga, Shin'ichiro; Miyamoto, Shingo

    2017-07-01

    Ovarian cancer is the most lethal malignancy among gynaecological cancers. Although many anticancer agents have been developed for the treatment of ovarian cancer, it continues to have an extremely poor prognosis. Heparin-binding epidermal growth factor-like grown factor (HB-EGF) has been reported to be a rational therapeutic target for ovarian cancer. Here, we evaluated the clinical significance of serum HB-EGF by examining the association between prognosis and serum HB-EGF levels in patients with primary ovarian cancer. We found that high serum HB-EGF concentrations were significantly associated with poor prognosis in a combined cohort of patients with all stages of ovarian cancer, as well as in a subset of patients with advanced disease. In addition, serum HB-EGF levels increased as the cancer advanced. These data suggest that serum HB-EGF may be a target for the design of novel therapies for ovarian cancer. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  1. Electronic Warfare Signature Measurement Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Electronic Warfare Signature Measurement Facility contains specialized mobile spectral, radiometric, and imaging measurement systems to characterize ultraviolet,...

  2. Values of HbCO in 1000 inhabitants of Milan non exposed to occupational absorption of CO

    Energy Technology Data Exchange (ETDEWEB)

    Grisler, R.; Gobbi, A.; Giavardi, C.; Caimmi, G.; Soverini, R.; Botta, A.

    1975-01-01

    Carboxyhemoglobin levels for 1000 non-occupationally exposed inhabitants of Milan were determined. The study group consisted of smokers and non-smokers; among the former, only individuals refraining from smoking for at least 10 hr were tested. The upper limit of the normal range for HbCO values among non-smokers was 2.85%, while among heavy smokers it was 4.59%. Heavy smokers also showed higher HbCO levels than did moderate smokers. Elevated HbCO values were also observed among residents living in carbon monoxide-polluted urban areas as compared with those living in unpolluted rural areas.

  3. Smoking: the influence of carboxyhemoglobin (HbCO) on tumor oxygenation and response to radiation

    International Nuclear Information System (INIS)

    Siemann, D.W.; Hill, R.P.; Bush, R.S.

    1978-01-01

    The effectiveness of localized x radiation on the transplantable KHT sarcoma was studied in nonanesthetized C3H mice possessing blood carboxyhemoglobin (HbCO) levels similar to those observed in heavy smokers. HbCO values of 10 percent were induced in tumor-bearing animals, either acutely just prior to irradiation or chronically during tumor growth and irradiation, by allowing the mice to breathe gas mixtures containing carbon monoxide (CO) in air. Tumors were irradiated either with single doses of 1500, 2000, or 2500 rad or with seven 500 rad fractions given at 24 hr intervals. Tumor cell survival was determined using an in vivo lung colony or an in vitro agar colony assay. The results with single doses of radiation indicate that under conditions of both acute and chronic exposure, the presence of 10 percent HbCO in the blood of the mice at the time of irradiation increases the survival of tumor cells in the hypoxic region of the survival curve by a factor of 2. During the fractionated irradiation, tumor cell survival in the presence of a 10 percent blood HbCO level (induced either acutely or chronically) was found to be significantly higher than that observed in air breathing mice. The results indicate that HbCO levels, such as are observed in heavy smokers, result in a larger fraction of hypoxic tumor cells. These findings suggest that heavy smoking prior to treatment may worsen the prognosis of patients undergoing radiotherapy

  4. Associations of HbA1c and educational level with risk of cardiovascular events in 32 871 drug-treated patients with Type 2 diabetes: a cohort study in primary care

    OpenAIRE

    ?stgren, C J; Sundstr?m, J; Svennblad, B; Lohm, L; Nilsson, P M; Johansson, G

    2013-01-01

    Aims To explore the association of HbA1c and educational level with risk of cardiovascular events and mortality in patients with Type 2 diabetes. Methods A cohort of 32 871 patients with Type 2 diabetes aged 35 years and older identified by extracting data from electronic patient records for all patients who had a diagnosis of Type 2 diabetes and had glucose-lowering agents prescribed between 1999 and 2009 at 84 primary care centres in Sweden. Associations of mean HbA1c levels and educational...

  5. Race-ethnic differences in the association of genetic loci with HbA1c levels and mortality in U.S. adults: the third National Health and Nutrition Examination Survey (NHANES III)

    Science.gov (United States)

    2012-01-01

    Background Hemoglobin A1c (HbA1c) levels diagnose diabetes, predict mortality and are associated with ten single nucleotide polymorphisms (SNPs) in white individuals. Genetic associations in other race groups are not known. We tested the hypotheses that there is race-ethnic variation in 1) HbA1c-associated risk allele frequencies (RAFs) for SNPs near SPTA1, HFE, ANK1, HK1, ATP11A, FN3K, TMPRSS6, G6PC2, GCK, MTNR1B; 2) association of SNPs with HbA1c and 3) association of SNPs with mortality. Methods We studied 3,041 non-diabetic individuals in the NHANES (National Health and Nutrition Examination Survey) III. We stratified the analysis by race/ethnicity (NHW: non-Hispanic white; NHB: non-Hispanic black; MA: Mexican American) to calculate RAF, calculated a genotype score by adding risk SNPs, and tested associations with SNPs and the genotype score using an additive genetic model, with type 1 error = 0.05. Results RAFs varied widely and at six loci race-ethnic differences in RAF were significant (p HbA1c in NHW (β = 0.012 HbA1c increase per risk allele, p = 0.04) and MA (β = 0.021, p = 0.005) but not NHB (β = 0.007, p = 0.39). The genotype score was not associated with mortality in any group (NHW: OR (per risk allele increase in mortality) = 1.07, p = 0.09; NHB: OR = 1.04, p = 0.39; MA: OR = 1.03, p = 0.71). Conclusion At many HbA1c loci in NHANES III there is substantial RAF race-ethnic heterogeneity. The combined impact of common HbA1c-associated variants on HbA1c levels varied by race-ethnicity, but did not influence mortality. PMID:22540250

  6. [Application of the polymerase chain reaction (PCR) in the diagnosis of Hb S-beta(+)-thalassemia].

    Science.gov (United States)

    Harano, K; Harano, T; Kushida, Y; Ueda, S

    1991-08-01

    Isoelectric focusing of the hemolysate prepared from a two-year-old American black boy with microcytic hypochromia showed the presence of a high percentage (63.3%) of such Hb variant as Hb S, while the levels of Hb A, Hb F and Hb A2 were 20.0%, 12.7%, and 4.0%, respectively. The ratio of the non-alpha-chain to the alpha-chain of the biosynthesized globin chains was 0.49. The variant was identified as Hb S by amino acid analysis of the abnormal peptide (beta T-1) and digestion of DNA amplified by the polymerase chain reaction with enzyme Eco 81 I. This was further confirmed by DNA sequencing. DNA sequencing of a beta-gene without the beta s-mutation revealed a nucleotide change of T to C in the polyadenylation signal sequence AATAAA 3' to the beta-gene, resulting in beta(+)-thalassemia. These results are consistent with the existence of a beta s-gene and a beta(+)-thalassemia gene in trans.

  7. The relationship between serum total testosterone and free testosterone levels with serum hemoglobin and hematocrit levels: a study in 1221 men.

    Science.gov (United States)

    Shin, Yu Seob; You, Jae Hyung; Cha, Jai Seong; Park, Jong Kwan

    2016-12-01

    To investigate the relationship between serum total testosterone (TT) and free testosterone (FT) levels in men with anemia. We reviewed the records of 1221 subjects between March 2009 and December 2014. All the subjects' blood samples were drawn for TT and FT assays. Their serum hemoglobin (Hb) and serum hematocrit (Hct) levels were measured. The primary objective of our study was to investigate the association between TT and FT levels with Hb and Hct levels. The mean age was 59.82 ± 12.71 years. The mean TT and FT levels were 4.54 ± 2.02 ng/mL and 10.63 ± 3.69 pg/mL, respectively. The mean Hb and Hct levels were 14.72 ± 1.34 g/dL and 43.11 ± 3.75%, respectively. Subjects with low TT (<2.35 ng/mL) had low Hb and Hct levels (p < 0.001, p < 0.001, respectively). TT was positively associated with FT, Hb, and Hct. TT and FT levels were significantly lower in older men. Subjects with low TT and FT levels had low Hb and Hct levels. This suggests that TT and FT play a significant role in erythropoiesis. Testosterone replacement therapy may be effective in men with hypogonadism to reduce the incidence of anemia.

  8. Universal HbA1c Measurement in Early Pregnancy to Detect Type 2 Diabetes Reduces Ethnic Disparities in Antenatal Diabetes Screening: A Population-Based Observational Study.

    Directory of Open Access Journals (Sweden)

    R C E Hughes

    Full Text Available In response to the type 2 diabetes epidemic, measuring HbA1c with the first-antenatal blood screen was recently recommended in NZ. This would enable prompt treatment of women with unrecognised type 2 diabetes, who may otherwise go undetected until the gestational diabetes (GDM screen. We compare inter-ethnic antenatal screening practices to examine whether the HbA1c test would be accessed by ethnicities most at risk of diabetes, and we determined the prevalence of unrecognised type 2 diabetes and prediabetes in our pregnant population. This is an observational study of pregnancies in Christchurch NZ during 2008-2010. Utilising electronic databases, we matched maternal characteristics to first-antenatal bloods, HbA1c, and GDM screens (glucose challenge tests and oral glucose tolerance tests. Overall uptake of the first-antenatal bloods versus GDM screening was 83.1% and 53.8% respectively in 11,580 pregnancies. GDM screening was lowest in Māori 39.3%, incidence proportion ratio (IPR 0.77 (0.71, 0.84 compared with Europeans. By including HbA1c with the first-antenatal bloods, the number screened for diabetes increases by 28.5% in Europeans, 40.0% in Māori, 28.1% in Pacific People, and 26.7% in 'Others' (majority of Asian descent. The combined prevalence of unrecognised type 2 diabetes and prediabetes by NZ criteria, HbA1c ≥5.9% (41mmol/mol, was 2.1% in Europeans, Māori 4.7% IPR 2.59 (1.71, 3.93, Pacific People 9.5% IPR 4.76 (3.10, 7.30, and 'Others' 6.2% IPR 2.99 (2.19, 4.07. Applying these prevalence data to 2013 NZ national births data, routine antenatal HbA1c testing could have identified type 2 diabetes in 0.44% and prediabetes in 3.96% of women. Routine HbA1c measurement in early pregnancy is an ideal screening opportunity, particularly benefitting vulnerable groups, reducing ethnic disparities in antenatal diabetes screening. This approach is likely to have world-wide relevance and applicability. Further research is underway to

  9. Relationship Between HbA1c and Complex Regional Pain Syndrome in Stroke Patients With Type 2 Diabetes Mellitus

    Science.gov (United States)

    2016-01-01

    Objective To investigate the relationship between glycosylated hemoglobin A (HbA1c) and complex regional pain syndrome (CRPS) in stroke patients with type 2 diabetes mellitus (T2DM). Methods A retrospective chart review was performed of stroke patients from January 2012 to December 2013. We reviewed 331 patients and included 200 in the analysis. We divided them into CRPS and non-CRPS groups and compared them by age, gender, stroke lesion, cause of stroke, duration of T2DM, HbA1c (%), National Institutes of Health Stroke Scale score, affected shoulder flexor muscle strength, Fugl-Meyer Assessment score, motricity index, Functional Independence Measure, Korean version of Modified Barthel Index, blood glucose level on admission day, duration from stroke onset to HbA1c check, and duration from stroke onset to three-phase bone scan for CRPS diagnosis. Thereafter, we classified the patients into five groups by HbA1c level (group 1, 5.0%–5.9%; group 2, 6.0%–6.9%; group 3, 7.0%–7.9%; group 4, 8.0%–8.9%; and group 5, 9.0%–9.9%) and we investigated the difference in CRPS prevalence between the two groups. Results Of the 200 patients, 108 were in the CRPS group and 92 were in the non-CRPS group. There were significant differences in HbA1c (pCRPS prevalence (pCRPS prevalence and thus that uncontrolled blood glucose can affect CRPS occurrence in stroke patients with diabetes. PMID:27847707

  10. National Survey on Internal Quality Control for HbA(1c) Analytical Instruments in 331 Hospital Laboratories of China.

    Science.gov (United States)

    Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo

    2015-01-01

    The narrow gap of HbA1 value of mass fraction between "normal" (control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.

  11. Race-ethnic differences in the association of genetic loci with HbA1c levels and mortality in U.S. adults: the third National Health and Nutrition Examination Survey (NHANES III).

    Science.gov (United States)

    Grimsby, Jonna L; Porneala, Bianca C; Vassy, Jason L; Yang, Quanhe; Florez, José C; Dupuis, Josée; Liu, Tiebin; Yesupriya, Ajay; Chang, Man-Huei; Ned, Renee M; Dowling, Nicole F; Khoury, Muin J; Meigs, James B

    2012-04-27

    Hemoglobin A1c (HbA1c) levels diagnose diabetes, predict mortality and are associated with ten single nucleotide polymorphisms (SNPs) in white individuals. Genetic associations in other race groups are not known. We tested the hypotheses that there is race-ethnic variation in 1) HbA1c-associated risk allele frequencies (RAFs) for SNPs near SPTA1, HFE, ANK1, HK1, ATP11A, FN3K, TMPRSS6, G6PC2, GCK, MTNR1B; 2) association of SNPs with HbA1c and 3) association of SNPs with mortality. We studied 3,041 non-diabetic individuals in the NHANES (National Health and Nutrition Examination Survey) III. We stratified the analysis by race/ethnicity (NHW: non-Hispanic white; NHB: non-Hispanic black; MA: Mexican American) to calculate RAF, calculated a genotype score by adding risk SNPs, and tested associations with SNPs and the genotype score using an additive genetic model, with type 1 error = 0.05. RAFs varied widely and at six loci race-ethnic differences in RAF were significant (p differed by race-ethnicity (NHW: 10.4, NHB: 11.0, MA: 10.7, p race-ethnic heterogeneity. The combined impact of common HbA1c-associated variants on HbA1c levels varied by race-ethnicity, but did not influence mortality.

  12. Screening Level Risk Assessment for the New Waste Calcining Facility

    Energy Technology Data Exchange (ETDEWEB)

    M. L. Abbott; K. N. Keck; R. E. Schindler; R. L. VanHorn; N. L. Hampton; M. B. Heiser

    1999-05-01

    This screening level risk assessment evaluates potential adverse human health and ecological impacts resulting from continued operations of the calciner at the New Waste Calcining Facility (NWCF) at the Idaho Nuclear Technology and Engineering Center (INTEC), Idaho National Engineering and Environmental Laboratory (INEEL). The assessment was conducted in accordance with the Environmental Protection Agency (EPA) report, Guidance for Performing Screening Level Risk Analyses at Combustion Facilities Burning Hazardous Waste. This screening guidance is intended to give a conservative estimate of the potential risks to determine whether a more refined assessment is warranted. The NWCF uses a fluidized-bed combustor to solidify (calcine) liquid radioactive mixed waste from the INTEC Tank Farm facility. Calciner off volatilized metal species, trace organic compounds, and low-levels of radionuclides. Conservative stack emission rates were calculated based on maximum waste solution feed samples, conservative assumptions for off gas partitioning of metals and organics, stack gas sampling for mercury, and conservative measurements of contaminant removal (decontamination factors) in the off gas treatment system. Stack emissions were modeled using the ISC3 air dispersion model to predict maximum particulate and vapor air concentrations and ground deposition rates. Results demonstrate that NWCF emissions calculated from best-available process knowledge would result in maximum onsite and offsite health and ecological impacts that are less then EPA-established criteria for operation of a combustion facility.

  13. Molecular Characteristics of Hb New York [β113(G15)Val→Glu, HBB: c.341T>A] in Thailand.

    Science.gov (United States)

    Chaibunruang, Attawut; Singha, Kritsada; Srivorakun, Hataichanok; Fucharoen, Goonnapa; Fucharoen, Supan

    2018-01-01

    Hb New York or Hb Kaohsiung [β113(G15)Val→Glu (GTG>GAG), HBB: c.341T>A] has been considered a rare β hemoglobin (Hb) variant found originally in an Iranian woman and later in diverse populations but its genetic origin has not been elucidated. Here we report molecular and hematological descriptions of this variant found in the Thai population. Among 5643 subjects referred for hemoglobinopathy investigation during January 2015 to September 2017, 183 (3.2%) were found to carry several Hb variants, including β chain variants (n = 135, 2.4%), α chain variants (n = 33, 0.6%), Hb Lepore-Hollandia (NG_000007.3: g.63290_70702del) and Hb Lepore-Boston-Washington (NG_000007.3: g.63632_71046del) (δβ hybrid Hb) (n = 12, 0.2%) and δ chain variants (n = 3, 0.05%). Of patients with β chain variants, six with normal high performance liquid chromatography (HPLC) patterns, had an abnormal Hb in zone 11 of capillary electrophoresis (CE), the amounts of which ranged from 29.6-45.4% with normal levels of Hb A 2 and Hb F. DNA analysis identified a heterozygous Hb New York mutation in all cases. Further screening of α-thalassemia (α-thal) identified coinheritance of α + - and α 0 -thal in two of them who had reduced levels of Hb New York. Haplotype analysis suggested that the Thai Hb New York was likely associated with a single β-globin haplotype [+ - - - - + +], indicating that it was of the same origin. Hematological findings and simple DNA assay based on allele-specific polymerase chain reaction (PCR) for rapid detection of Hb New York are presented.

  14. Noninvasive Measurement of Hemoglobin Using Spectrophotometry: Is it Useful for the Critically Ill Child?

    Science.gov (United States)

    Akyildiz, Basak

    2018-01-01

    This study compared the accuracy of noninvasively measuring hemoglobin using spectrophotometry (SpHb) with a pulse CO-oximeter and laboratory hemoglobin (Hb) measurements. A total of 345 critically ill children were included prospectively. Age, sex, and factors influencing the reliabilityof SpHb such as SpO2, heart rate, perfusion index (PI), and vasoactive inotropic score were recorded. SpHb measurements were recorded during the blood draw and compared with the Hb measurement. Thirteen patients (low PI in 9 patients and no available Hb in 4 patients) were excluded and 332 children were eligible for final analysis. The mean Hb was 8.71±1.49 g/dL (range, 5.9 to 12 g/dL) and the mean SpHb level was 9.55±1.53 g/dL (range, 6 to 14.2 g/dL). The SpHb bias was 0.84±0.86,with the limits of agreement ranging from -2.5 to 0.9 g/dL. The difference between Hb and SpHb was >1.5 g/dL for only 47 patients. Of these, 24 patients had laboratory Hb levels <7 g/dL. There was a weak positive correlation between differences and PI (r=0.349; P= 0.032). The pulse CO-oximeter is a promising tool for measuring SpHb and monitoring critically ill children. However, PI may affect these results. Additional studies investigating the reliability of the trend of continuous SpHb values compared with simultaneously measured laboratory Hb values in the same patient are warranted.

  15. HbA(1c) levels in non-diabetic Dutch children aged 8-9 years : the PIAMA birth cohort study

    NARCIS (Netherlands)

    Jansen, H.; Wijga, A. H.; Smit, H. A.; Scholtens, S.; Kerkhof, M.; Koppelman, G. H.; de Jongste, J. C.; Stolk, R. P.

    Glycated haemoglobin (HbA(1c)) is considered the best index of glycaemic control in established diabetes. It may also be useful in the diagnosis of diabetes and as a screening tool. Little is known about the distribution of HbA(1c) in healthy children and its predictors. The aim of this study is to

  16. Seed-specific elevation of non-symbiotic hemoglobin AtHb1: beneficial effects and underlying molecular networks in Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Tschiersch Henning

    2011-03-01

    Full Text Available Abstract Background Seed metabolism is dynamically adjusted to oxygen availability. Processes underlying this auto-regulatory mechanism control the metabolic efficiency under changing environmental conditions/stress and thus, are of relevance for biotechnology. Non-symbiotic hemoglobins have been shown to be involved in scavenging of nitric oxide (NO molecules, which play a key role in oxygen sensing/balancing in plants and animals. Steady state levels of NO are suggested to act as an integrator of energy and carbon metabolism and subsequently, influence energy-demanding growth processes in plants. Results We aimed to manipulate oxygen stress perception in Arabidopsis seeds by overexpression of the non-symbiotic hemoglobin AtHb1 under the control of the seed-specific LeB4 promoter. Seeds of transgenic AtHb1 plants did not accumulate NO under transient hypoxic stress treatment, showed higher respiratory activity and energy status compared to the wild type. Global transcript profiling of seeds/siliques from wild type and transgenic plants under transient hypoxic and standard conditions using Affymetrix ATH1 chips revealed a rearrangement of transcriptional networks by AtHb1 overexpression under non-stress conditions, which included the induction of transcripts related to ABA synthesis and signaling, receptor-like kinase- and MAP kinase-mediated signaling pathways, WRKY transcription factors and ROS metabolism. Overexpression of AtHb1 shifted seed metabolism to an energy-saving mode with the most prominent alterations occurring in cell wall metabolism. In combination with metabolite and physiological measurements, these data demonstrate that AtHb1 overexpression improves oxidative stress tolerance compared to the wild type where a strong transcriptional and metabolic reconfiguration was observed in the hypoxic response. Conclusions AtHb1 overexpression mediates a pre-adaptation to hypoxic stress. Under transient stress conditions transgenic seeds

  17. Special Analysis for Disposal of High-Concentration I-129 Waste in the Intermediate-Level Vaults at the E-Area Low-Level Waste Facility

    Energy Technology Data Exchange (ETDEWEB)

    Collard, L.B.

    2000-09-26

    This revision was prepared to address comments from DOE-SR that arose following publication of revision 0. This Special Analysis (SA) addresses disposal of wastes with high concentrations of I-129 in the Intermediate-Level (IL) Vaults at the operating, low-level radioactive waste disposal facility (the E-Area Low-Level Waste Facility or LLWF) on the Savannah River Site (SRS). This SA provides limits for disposal in the IL Vaults of high-concentration I-129 wastes, including activated carbon beds from the Effluent Treatment Facility (ETF), based on their measured, waste-specific Kds.

  18. Special Analysis for Disposal of High-Concentration I-129 Waste in the Intermediate-Level Vaults at the E-Area Low-Level Waste Facility

    International Nuclear Information System (INIS)

    Collard, L.B.

    2000-01-01

    This revision was prepared to address comments from DOE-SR that arose following publication of revision 0. This Special Analysis (SA) addresses disposal of wastes with high concentrations of I-129 in the Intermediate-Level (IL) Vaults at the operating, low-level radioactive waste disposal facility (the E-Area Low-Level Waste Facility or LLWF) on the Savannah River Site (SRS). This SA provides limits for disposal in the IL Vaults of high-concentration I-129 wastes, including activated carbon beds from the Effluent Treatment Facility (ETF), based on their measured, waste-specific Kds

  19. NEAR-IR PHOTOMETRIC PROPERTIES OF HB, MSTO, AND SGB FOR METAL POOR GALACTIC GLOBULAR CLUSTERS

    Directory of Open Access Journals (Sweden)

    J.-W. Kim

    2007-03-01

    Full Text Available We report photometric features of the HB, MSTO, and SGB for a set of metal-poor Galactic globular clusters on the near-IR CMDs. The magnitude and color of the MSTO and SGB are measured on the fiducial normal points of the CMDs by applying a polynomial fit. The near-IR luminosity functions of horizontal branch stars in the classical second parameter pair M3 and M13 indicate that HB stars in M13 are dominated by hot stars that are rotatively faint in the infrared, whereas HB stars in M3 are brighter than those in M13. The luminosity functions of HB stars in the observed bulge clusters, except for NGC 6717, show a trend that the fainter hot HB stars are dominated in the relatively metal-poor clusters while the relatively metal-rich clusters contain the brighter HB stars. It is suggestive that NGC 6717 would be an extreme example of the second-parameter phenomenon for the bulge globular clusters.

  20. Pregnancy outcome in patients with sickle cell disease in the UK--a national cohort study comparing sickle cell anaemia (HbSS) with HbSC disease.

    Science.gov (United States)

    Oteng-Ntim, Eugene; Ayensah, Benjamin; Knight, Marian; Howard, Jo

    2015-04-01

    We describe the findings from a national study of maternal and fetal outcomes of pregnancy in women with sickle cell disease (SCD). Data were collected via the United Kingdom Obstetric Surveillance System between 1 February 2010 and 31 January 2011 from 109 women, of whom 51 (46·8%) had HbSS and 44 (40·4%) had HbSC. Data included antenatal, maternal and fetal outcomes. Comparisons were made between women with HbSS and HbSC. Incidence of complications were acute pain (57%), blood transfusion (26%), urinary tract infection (UTI; 12%) and critical care unit admission (23%) and these were all more common in women with HbSS than HbSC. There was no difference in the incidence of acute chest syndrome, hypertension and venous thromboembolism between HbSS and HbSC. Women with HbSS were more likely to deliver at pregnancy. © 2014 John Wiley & Sons Ltd.

  1. Diagnostic accuracy of HbA1c in diabetes between Eastern and Western.

    Science.gov (United States)

    Yan, Shuang; Liu, Siying; Zhao, Yashuang; Zhang, Wencui; Sun, Xiaohui; Li, Jianing; Jiang, Fuli; Ju, Jiaming; Lang, Ning; Zhang, Yingqi; Zhou, Weiyu; Li, Qiang

    2013-07-01

    In 2010, the American Diabetes Association recommended the use of HbA1c as a diagnostic criterion for diabetes. However, HbA1c is not an accepted diagnostic tool for diabetes in Eastern Asia, because genetic differences compromise the standardization of the diagnostic cut-off point. This study evaluated differences in the use of HbA1c for diagnosing diabetes in Eastern and Western populations and investigated whether HbA1c cut-off point of ≥ 6.5% is diagnostic of diabetes in patients from Eastern Asia. Literature was obtained from MEDLINE, EMBASE and Cochrane databases. The pooled sensitivity and specificity of each HbA1c cut-off point were extracted and compared between Western and Eastern populations. Differences in the cut-off point for diagnosing diabetes in each region were compared by examining differences in the area under summary receiver operating characteristic (SROC) curves. Twelve publications from Eastern countries (n = 59,735) and 13 from Western countries (n = 22,954) were included in the analysis. Areas under SROC curves in the Eastern and Western groups were 0.9331 and 0.9120, respectively (P = 0.98). The cut-off point of the highest Youden index was 6.0%. At the HbA1c cut-off point of 6.5%, the pooled sensitivity and specificity were 58.7% and 98.4% for Eastern countries and 65.5% and 98.1% for Western countries, respectively. HbA1c exhibits the same diagnostic value for diabetes in Eastern and Western populations. In both populations, HbA1c levels > 6.0% identify the population at high risk of diabetes, and HbA1c > 6.5% is diagnostic of clinically established diabetes. © 2013 Stichting European Society for Clinical Investigation Journal Foundation. Published by John Wiley & Sons Ltd.

  2. HbA1c monitoring interval in patients on treatment for stable type 2 diabetes. A ten-year retrospective, open cohort study.

    Science.gov (United States)

    Ohde, Sachiko; Deshpande, Gautam A; Yokomichi, Hiroshi; Takahashi, Osamu; Fukui, Tsuguya; Yamagata, Zentaro

    2018-01-01

    [Aims] This study aims to suggest an informative interval for HbA1c in DM patients with stable glycemic control, based on test characteristics of the HbA1C assay using the signal-to-noise ratio method. [Methods] This was a retrospective, open cohort study. Data were collected between January 2005 to December 2014 at a tertiary-level community hospital in Japan. All adult patients aged under 75 years, with stable glycemic control on a first pharmaceutical regimen for Type II diabetes, and at least two HbA1c measurements after they achieved glycemic stability, were included in the analysis. We defined stable glycemic control as HbA1c HbA1c. The screening interval for HbA1c was defined as informative when the signal-to-noise ratio exceeded 1. [Results] Among 1066 adults with diabetes, 639 patients (18.5%) were identified as achieving stable glycemic control (511 male (67.3%)), with a mean HbA1c (SD) of 6.4 (0.4)% (46 mmol/mol). Patients with stable glycemic control increase their HbA1c 0.27% (3 mmol/mol) every year while HbA1c has 0.32% (3.5 mmol/mol) noise, as testing characteristics. Signal exceeds noise after 1.2 years (95%CI: 0.9-1.6). [Conclusion] Once patients achieve stable glycemic control at their HbA1c goal, an informative interval for HbA1c monitoring is once every year. Current guidelines, which suggest testing every six months, may contribute to substantial over-testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  3. HbA1c Variability as an Independent Correlate of Nephropathy, but Not Retinopathy, in Patients With Type 2 Diabetes

    Science.gov (United States)

    Penno, Giuseppe; Solini, Anna; Bonora, Enzo; Fondelli, Cecilia; Orsi, Emanuela; Zerbini, Gianpaolo; Morano, Susanna; Cavalot, Franco; Lamacchia, Olga; Laviola, Luigi; Nicolucci, Antonio; Pugliese, Giuseppe

    2013-01-01

    OBJECTIVE To examine the association of hemoglobin (Hb) A1c variability with microvascular complications in the large cohort of subjects with type 2 diabetes from the Renal Insufficiency And Cardiovascular Events (RIACE) Italian Multicenter Study. RESEARCH DESIGN AND METHODS Serial (3–5) HbA1c values collected in a 2-year period before enrollment were available from 8,260 subjects from 9 centers (of 15,773 patients from 19 centers). HbA1c variability was measured as the intraindividual SD of 4.52 ± 0.76 values. Diabetic retinopathy (DR) was assessed by dilated funduscopy. Chronic kidney disease (CKD) was defined based on albuminuria, as measured by immunonephelometry or immunoturbidimetry, and estimated glomerular filtration rate (eGFR) was calculated from serum creatinine. RESULTS Median and interquartile range of average HbA1c (HbA1c-MEAN) and HbA1c-SD were 7.57% (6.86–8.38) and 0.46% (0.29–0.74), respectively. The highest prevalence of microalbuminuria, macroalbuminuria, reduced eGFR, albuminuric CKD phenotypes, and advanced DR was observed when both HbA1c parameters were above the median and the lowest when both were below the median. Logistic regression analyses showed that HbA1c-SD adds to HbA1c-MEAN as an independent correlate of microalbuminuria and stages 1–2 CKD and is an independent predictor of macroalbuminuria, reduced eGFR, and stages 3–5 albuminuric CKD, whereas HbA1c-MEAN is not. The opposite was found for DR, whereas neither HbA1c-MEAN nor HbA1c-SD affected nonalbuminuric CKD. CONCLUSIONS In patients with type 2 diabetes, HbA1c variability affects (albuminuric) CKD more than average HbA1c, whereas only the latter parameter affects DR, thus suggesting a variable effect of these measures on microvascular complications. PMID:23491522

  4. 2,3-DPG-Hb complex: a hypothesis for an asymmetric binding.

    Science.gov (United States)

    Pomponi, M; Bertonati, C; Fuglei, E; Wiig, O; Derocher, A E

    2000-05-15

    This study was undertaken to test the symmetry of 2,3-diphosphoglycerate (2,3-DPG) binding site in hemoglobin (Hb). From Arnone's study [A. Arnone, Nature (London) 237 (1972) 146] the 2,3-DPG binding site is located at the top of the cavity, that runs through the center of the deoxy-Hb molecule. However, it is possible that this symmetry reported by Arnone, for crystals of 2,3-DPG-Hb complex, might not be conserved in solution. In this paper, we report the 31P nuclear magnetic resonances of the 2,3-DPG interaction with Hb. The 2,3-DPG chemical shifts of the P2 and P3 resonance are both pH- and hemoglobin-dependent [protein from man, polar bear (Ursus maritimus), Arctic fox (Alopex lagopus) and bovine]. 2,3-DPG binds tightly to deoxyhemoglobin and weakly, nevertheless significantly, to oxyhemoglobin. In particular, our results suggest similar spatial position of the binding site of 2,3-DPG in both forms of Hb in solutions. However, the most unexpected result was the apparent loss of symmetry in the binding site, which might correlate with the ability of the hemoglobin to modulate its functional behavior. The different interactions of the phosphate groups indicate small differences in the quaternary structure of the different deoxy forms of hemoglobin. Given the above structural perturbation an asymmetric binding in the complex could justify, at least in part, different physiological properties of Hb. Regardless, functionally relevant effects of 2,3-DPG seem to be measured and best elucidated through solution studies.

  5. [Hb Burgos (α1 CD64(E13)(Asp→Asn)): a new hemoglobin variant detected during follow-up of diabetic patients].

    Science.gov (United States)

    de la Fuente-Gonzalo, Félix; Martínez Nieto, Jorge; Torrejón, María José; Mayor, Luis Antonio; Velasco, Diego; González Fernández, Fernando Ataulfo; Ropero Gradilla, Paloma

    2015-01-06

    The glycated hemoglobin (HbA1c) test by high performance liquid chromatography is a useful tool for the follow-up of diabetes mellitus patients. Some structural hemoglobin (Hb) variants are known to cause interference in the analytical measurement of HbA1c. In this study, it has been characterized a new Hb variant in 4 patients during their regular control of HbA1c. Selective α1 gene sequencing showed a mutation GAC>AAC at codon 64 within exon 2. This produces a change of aspartic acid (Asp) by asparagine (Asn) that does not produce any functional alteration so the resultant molecule behaves as a silent hemoglobinopathy. The structural Hb variants can be detected during the analysis of HbA1c and may alter its values. Though rare, this occurrence signals the need to being aware when measuring HbA1c. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  6. Genome-wide association study identifies common loci influencing circulating glycated hemoglobin (HbA1c) levels in non-diabetic subjects

    DEFF Research Database (Denmark)

    An, Ping; Miljkovic, Iva; Thyagarajan, Bharat

    2014-01-01

    Glycated hemoglobin (HbA1c) is a stable index of chronic glycemic status and hyperglycemia associated with progressive development of insulin resistance and frank diabetes. It is also associated with premature aging and increased mortality. To uncover novel loci for HbA1c that are associated with...

  7. Characterization of Hb Lepore variants in the UK population.

    Science.gov (United States)

    Guo, Lina; Kausar, Anika; Old, John M; Henderson, Shirley J; Gallienne, Alice E

    2015-01-01

    A molecular study of Hb Lepore heterozygotes identified by the UK population screening program has revealed four out of the five known Lepore variants. The region of homologous δ- and β-globin gene sequence was determined in 58 unrelated Hb Lepore heterozygotes referred for confirmation of their carrier status by DNA analysis through the national thalassemia and sickle cell screening program over a period of 10 years. The most common variant found was Hb Lepore-Boston-Washington (Hb LBW, HBD: c.265 C > c.315 + 7 C) observed in 46 carriers (79.0%). Hb Lepore-Hollandia (HBD: c.69 A > c.92 + 16 A) was found in nine cases (16.0%); Hb Lepore-Baltimore (HBD: c.208 G > c.254 C) in two cases (4.0%) and Hb Lepore-ARUP (HBD: c.97 C > c.150 C) in one carrier (2.0%). Analysis of the hematological findings showed no significant differences between the four groups. The wide range of Hb Lepore variants observed in this study confirms the very diverse range of α- and β-globin gene mutations observed in the UK population by previous studies.

  8. Effects of a healthier snack on snacking habits and glycated Hb (HbA1c): a 6-week intervention study.

    Science.gov (United States)

    Yan, Mary R; Parsons, Andrew; Whalley, Gillian A; Rush, Elaine C

    2016-12-01

    Dietary behaviour modification may change eating habits and reduce the impact of poor nutrition. This study aimed to evaluate the effects of daily consumption of a healthier snack bar on snacking habits and glycated Hb (HbA1c) within a 6-week intervention. In all, twenty-eight participants were randomly allocated to two groups to either consume the bars as the main snack for 6 weeks (n 14) or receipt of the bars was delayed for 6 weeks (n 14) following a stepped-wedge design. All participants had HbA1c concentrations measured at weeks -1, 0, 4, 6, 10 and 12. A short dietary habits questionnaire was self-completed at weeks 0, 6 and 12. Participants consumed the bars they received instead of other snacks, and found that the healthier snack bar was acceptable as part of their daily dietary pattern. Over the 12 weeks, there was a significant reduction in intake of biscuits, cakes and pies (approximately 2 servings/week, Psnack intervention and a trend towards a favourable effect on glucose homoeostasis. Habitual snacking behaviour has the potential to be improved through changes in the food supply, and in the longer term may reduce the impact of poor nutrition on public health.

  9. Hb D/Talassemia beta associada à anemia crônica Hb D/ Beta thalassaemia associated with chronic anaemia

    Directory of Open Access Journals (Sweden)

    Paulo C. Naoum

    2002-03-01

    Full Text Available We describe a case of Hb D/Beta thalassemia associated with chronic anemia. Hematological analyses performed in a patient with chronic anemia demonstrating microcytosis and hypochromic in his erythrocytes. Specific laboratory diagnosis performed by alkaline and acid electrophoresis, and fetal determination by alkali resistance, indicated it to be Hb D associated with beta thalassemia. Analyses carried out on his family (father, mother and brother confirmed the suspected diagnosis. Hb D/Beta thalassemia is a very rare interaction in the Brazilian population, and its determination required specific laboratorial techniques and hematological analyses.

  10. FAMILY BEHAVIOR IN MAINTENANCE STATUS HB CHRONIC RENAL FAILURE PATIENTS THROUGH FAMILY CENTERED CARE APPROACH OF DIET FE MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Anggia Fajar Hardianti

    2017-04-01

    Full Text Available Introduction: Erythropoietic agent as standard practice for anemia treatment, which has a function to increase the value of hemoglobin (Hb to 12 g/dl in patients with chronic renal failure (CRF, who receiving dialysis treatment. The use of erythropoietin has to keep of the iron/Fe amount in the body. Family who have a duty of care should have knowledge, attitude, and behavior to maintain patient’s Hb by giving support to the patient to obey the Fe diet. The aimed of this study was to investigate the effect of family centered care approach in management Fe diet toward family’s behaviour in maintenance Hb level of CRF patients in hemodialysis ward, Gambiran Hospital, Kediri. Method: This study was used a pre experimental design. Total sample were 10 respondents, who met to inclusion criteria. The independent variables were knowledge, attitude, and psychomotor of family in maintenance of Hb level in CRF’s patients. The dependent variable was Fe diet management with family centered care approach. Data was collected by using a structured questionnaire and home visit observation. Result: Data was analyzed by using Wilcoxon Sign Rank Test with significance level α≤0.05. Results showed that Fe diet management with family centered care approach took effect to family’s knowledge (p=0.011, family’s attitude (p=0.005 and family’s psychomotor (p=0.005 in maintenance Hb level of CRF patients. Discussion: Family’s knowledge, attitude, and psychomotor were effected by experiences during the care of a patient, not affordable to access information and patient’s own decision. The strengths and weaknesses in the family to got a better plan of care can be made by discuss and sharing among researcher, patient and his family. It can be concluded that Fe diet management with family centered care approach took effect to family’s behaviour. Further studies should involve larger respondents and better measurement tools to obtain more accurate results.

  11. HB-GAM (pleiotrophin) reverses inhibition of neural regeneration by the CNS extracellular matrix

    Science.gov (United States)

    Paveliev, Mikhail; Fenrich, Keith K.; Kislin, Mikhail; Kuja-Panula, Juha; Kulesskiy, Evgeny; Varjosalo, Markku; Kajander, Tommi; Mugantseva, Ekaterina; Ahonen-Bishopp, Anni; Khiroug, Leonard; Kulesskaya, Natalia; Rougon, Geneviève; Rauvala, Heikki

    2016-01-01

    Chondroitin sulfate (CS) glycosaminoglycans inhibit regeneration in the adult central nervous system (CNS). We report here that HB-GAM (heparin-binding growth-associated molecule; also known as pleiotrophin), a CS-binding protein expressed at high levels in the developing CNS, reverses the role of the CS chains in neurite growth of CNS neurons in vitro from inhibition to activation. The CS-bound HB-GAM promotes neurite growth through binding to the cell surface proteoglycan glypican-2; furthermore, HB-GAM abrogates the CS ligand binding to the inhibitory receptor PTPσ (protein tyrosine phosphatase sigma). Our in vivo studies using two-photon imaging of CNS injuries support the in vitro studies and show that HB-GAM increases dendrite regeneration in the adult cerebral cortex and axonal regeneration in the adult spinal cord. Our findings may enable the development of novel therapies for CNS injuries. PMID:27671118

  12. Changes in HbA1c levels and body mass index after successful decompression surgery in patients with type 2 diabetes mellitus and lumbar spinal stenosis: results of a 2-year follow-up study.

    Science.gov (United States)

    Kim, Kyoung-Tae; Cho, Dae-Chul; Sung, Joo-Kyung; Kim, Chi Heon; Kang, Hyun; Kim, Du Hwan

    2017-02-01

    Lumbar spinal stenosis (LSS) can hinder a patient's physical activity, which in turn can impair glucose tolerance and body weight regulation in patients with type 2 diabetes mellitus (DM-2). Therefore, successful lumbar surgery could facilitate glycemic control and body weight regulation. This study aimed to evaluate the effects of postoperative improvement in physical activity on body mass index (BMI) and hemoglobin A 1c (HbA 1c ) level in patients with LSS and DM-2 over a 2-year follow-up period. Prospective longitudinal observational study. Patients with LSS and DM-2. Visual analogue scale (VAS) scores for back pain and leg pain, Oswestry Disability Index (ODI) scores, Japanese Orthopaedic Association (JOA) scores, JOA Back Pain Evaluation Questionnaire (JOABPEQ) sections, BMI, and blood analysis for HbA 1c were carried out. A total of 119 patients were enrolled for analysis of the effect of successful decompression surgery on changes in HbA 1c levels and BMI. The VAS score, ODI score, JOA score, JOABPEQ, BMI, HbA 1c were reassessed at 6 months, 1 year, and 2 years after surgery. Additionally, correlations between changes in HbA 1c and changes in the ODI, JOA, JOABPEQs, and BMI were analyzed. The overall values of HbA1c before and at 6 months, 1 year, and 2 years after the surgery were 7.08±0.94%, 6.58±0.87%, 6.59±0.79%, and 6.59±0.79%, respectively (p-values; 6 months: .024; 1 year: .021; 2 years: .038). In the not well-controlled sugar (non-WCS) group (preoperative HbA 1c >6.5%), the difference between pre- and postoperative HbA 1c was highly statistically significant (p25) patients with DM-2 and LSS. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Single-cell measurement of red blood cell oxygen affinity.

    Science.gov (United States)

    Di Caprio, Giuseppe; Stokes, Chris; Higgins, John M; Schonbrun, Ethan

    2015-08-11

    Oxygen is transported throughout the body by hemoglobin (Hb) in red blood cells (RBCs). Although the oxygen affinity of blood is well-understood and routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of RBC volume and Hb concentration are taken millions of times per day by clinical hematology analyzers, and they are important factors in determining the health of the hematologic system. To better understand the variability and determinants of oxygen affinity on a cellular level, we have developed a system that quantifies the oxygen saturation, cell volume, and Hb concentration for individual RBCs in high throughput. We find that the variability in single-cell saturation peaks at an oxygen partial pressure of 2.9%, which corresponds to the maximum slope of the oxygen-Hb dissociation curve. In addition, single-cell oxygen affinity is positively correlated with Hb concentration but independent of osmolarity, which suggests variation in the Hb to 2,3-diphosphoglycerate (2-3 DPG) ratio on a cellular level. By quantifying the functional behavior of a cellular population, our system adds a dimension to blood cell analysis and other measurements of single-cell variability.

  14. Single, community-based blood glucose readings may be a viable alternative for community surveillance of HbA1c and poor glycaemic control in people with known diabetes in resource-poor settings

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2016-08-01

    Full Text Available Background: The term HbA1c (glycated haemoglobin is commonly used in relation to diabetes mellitus. The measure gives an indication of the average blood sugar levels over a period of weeks or months prior to testing. For most low- and middle-income countries HbA1c measurement in community surveillance is prohibitively expensive. A question arises about the possibility of using a single blood glucose measure for estimating HbA1c and therefore identifying poor glycaemic control in resource-poor settings. Design: Using data from the 2011–2012 US National Health and Nutrition Examination Surveys, we examined the relationship between HbA1c and a single fasting measure of blood glucose in a non-clinical population of people with known diabetes (n=333. A linear equation for estimating HbA1c from blood glucose was developed. Appropriate blood glucose cut-off values were set for poor glycaemic control (HbA1c≥69.4 mmol/mol. Results: The HbA1c and blood glucose measures were well correlated (r=0.7. Three blood glucose cut-off values were considered for classifying poor glycaemic control: 8.0, 8.9, and 11.4 mmol/L. A blood glucose of 11.4 had a specificity of 1, but poor sensitivity (0.37; 8.9 had high specificity (0.94 and moderate sensitivity (0.7; 8.0 was associated with good specificity (0.81 and sensitivity (0.75. Conclusions: Where HbA1c measurement is too expensive for community surveillance, a single blood glucose measure may be a reasonable alternative. Generalising the specific results from these US data to low resource settings may not be appropriate, but the general approach is worthy of further investigation.

  15. Regional variations in frequency of glycosylated hemoglobin (HbA1c) monitoring in Korea: A multilevel analysis of nationwide data.

    Science.gov (United States)

    Yoo, Kyoung-Hun; Shin, Dong-Wook; Cho, Mi-Hee; Kim, Sang-Hyuck; Bahk, Hyun-Jung; Kim, Shin-Hye; Jeong, Su-Min; Yun, Jae-Moon; Park, Jin-Ho; Kim, Heesun; Cho, BeLong

    2017-09-01

    Suboptimal frequency of glycosylated hemoglobin (HbA1c) monitoring is associated with poor diabetes control. We aimed to analyze compliance to HbA1c testing guidelines and explore associated individual and area-level determinants, focusing on regional variation. This cross-sectional study between the period of 2012-2013 was conducted by using the Korean National Health Insurance Research Database, and included 45,634 patients diagnosed with diabetes mellitus, who were prescribed any anti-diabetic medications, including insulin. We calculated the proportion of each HbA1c testing frequency (≥1, ≥2, or ≥4 times per year) stratified by 17 administrative regions. Multilevel and multivariate logistic analyses were performed with regional (proportion of farmer population) and individual characteristics (age, sex, income level, duration of diabetes, and most visited medical institution). Overall, 67.3% of the patients received≥1 HbA1c test per year; 37.8% and 6.1% received ≥2 and ≥4 tests per year, respectively. Those managed in secondary-level hospitals or clinics and those living in rural areas were less likely to receive HbA1c testing. Even after adjusting for individual and regional level characteristics, significant area level variation was observed (variance participant coefficients were 7.91%, 9.58%, and 14.43% for testing frequencies of ≥1, ≥2, and ≥4 times a year, respectively). The frequency of HbA1c monitoring is suboptimal in Korea, especially in rural areas. Moreover, significant regional variation was observed, implying a contextual effect. This suggests the need for developing policy actions to improve HbA1c monitoring. In particular, access to HbA1c testing in rural primary care clinics must be improved. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Performance d’Hemocue Hb 201+ dans le diagnostic de l’anémie de l’enfant dans les structures sanitaires du niveau périphérique au Togo

    Directory of Open Access Journals (Sweden)

    Ahoefa Vovor

    2013-12-01

    on the economic and social development of a country. Effective care of anaemic patients requires a reliable and precisediagnostic test that can determine haemoglobin levels. Objective: To evaluate the diagnostic performance of the Hemocue test Hb201+®. Method: This study compared haemoglobin levels measured using the photometer Hemocue Hb201+® with those measured by analysers of haematology. Children aged 6 to 59 months who suffered from uncomplicated malaria were eligible for inclusion. Haemoglobin levels determined by the analysers were considered the reference for evaluation of the levels measured using Hemocue Hb201+®. Results: 72.8% of the values obtained by Hemocue Hb201® were within ±1g/dl of the reference value. The Pearson correlation coefficient was 0.80. The prevalence of anaemia was 79.3% using the reference method and 77.9% using Hemocue 201+®. The sensitivity and the specificity of Hemocue Hb201+® were 95.1% and 65.3% respectively. Conclusion: The study results showed that the Hemocue Hb201 test+® provided good sensitivity, average specificity and average precision, both for the diagnosis of anaemia and for the determination of haemoglobin levels. It may be used in peripheral centres to facilitate the laboratory diagnosis of anaemia and its management in populations that live in areas with difficult accessibility.

  17. Facility for the measurement of proton polarization in nuclear reactions

    Energy Technology Data Exchange (ETDEWEB)

    Slobodrian, R J; Irshad, M; Labrie, R; Rioux, C; Roy, R; Pigeon, R [Laval Univ., Quebec City (Canada). Lab. de Physique Nucleaire

    1979-02-15

    A polarimetry facility based on high resolution and high efficiency silicon polarimeters with on-line particle identification is described. It has proven its capability to measure polarization in (/sup 3/He, p(pol)) reaction with cross section levels of 40 ..mu..b/sr.

  18. Pediatric diabetes consortium type 1 diabetes new onset (NeOn) study: Factors associated with HbA1c levels one year after diagnosis

    Science.gov (United States)

    To identify determinants of hemoglobin A1c (HbA1c) levels 1 yr after the diagnosis of type 1 diabetes (T1D) in participants in the Pediatric Diabetes Consortium (PDC) T1D New Onset (NeOn) Study. Diabetes-specific as well as socioeconomic factors during the first year following diagnosis were analyze...

  19. The effectiveness of theory- and model-based lifestyle interventions on HbA1c among patients with type 2 diabetes: a systematic review and meta-analysis.

    Science.gov (United States)

    Doshmangir, P; Jahangiry, L; Farhangi, M A; Doshmangir, L; Faraji, L

    2018-02-01

    The prevalence of type 2 diabetes is rising rapidly around the world. A number of systematic reviews have provided evidence for the effectiveness of lifestyle interventions on diabetic patients. The effectiveness of theory- and model-based education-lifestyle interventions for diabetic patients are unclear. The systematic review and meta-analysis aimed to evaluate and quantify the impact of theory-based lifestyle interventions on type 2 diabetes. A literature search of authentic electronic resources including PubMed, Scopus, and Cochrane collaboration was performed to identify published papers between January 2002 and July 2016. The PICOs (participants, intervention, comparison, and outcomes) elements were used for the selection of studies to meet the inclusion and exclusion criteria. Mean differences and standard deviations of hemoglobin A1c (HbA1c [mmol/mol]) level in baseline and follow-up measures of studies in intervention and control groups were considered for data synthesis. A random-effects model was used for estimating pooled effect sizes. To investigate the source of heterogeneity, predefined subgroup analyses were performed using trial duration, baseline HbA1c (mmol/mol) level, and the age of participants. Meta-regression was performed to examine the contribution of trial duration, baseline HbA1c (mmol/mol) level, the age of participants, and mean differences of HbA1c (mmol/mol) level. The significant level was considered P HbA1c (mmol/mol) -5.35% (95% confidence interval = -6.3, -4.40; P HbA1c (mmol/mol) indices in patients with type 2 diabetes. Health education theories have been applied as a useful tool for lifestyle change among people with type 2 diabetes. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  20. Is there a role for HbA1c in predicting mortality and morbidity outcomes after coronary artery bypass graft surgery?

    Science.gov (United States)

    Tennyson, Charlene; Lee, Rebecca; Attia, Rizwan

    2013-01-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was is there a role for HbA1c in predicting morbidity and mortality outcomes after coronary artery bypass surgery? Eleven studies presented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The studies presented analyse the relationship between preoperative HbA1c levels and postoperative outcomes following coronary artery bypass graft (CABG) in diabetic, non-diabetic or mixed patient groups. Four studies found significant increases in early and late mortality at higher HbA1c levels, regardless of a preoperative diagnosis of diabetes. One study demonstrated that 30-day survival outcomes were significantly worse in patients with previously undiagnosed diabetes and elevated HbA1c compared with those with good control [HbA1c >6%; odds ratio 1.53, confidence interval (CI) (1.24–1.91); P = 0.0005]. However, four studies of early mortality outcomes in diabetic patients only showed no significant differences between patients with normal and those with deranged HbA1c levels (P = 0.99). There were mixed reports on morbidity outcomes. Three studies identified a significant increase in infectious complications in patients with poorly controlled HbA1c, two of which were irrespective of previous diabetic status [deep sternal wound infection (P = 0.014); superficial sternal wound infection (P = 0.007) and minor infections (P = 0.006) in poorly controlled diabetics only]. Four studies presented outcomes for total length of stay (LOS). Three of these papers looked specifically at diabetic patients, of which two found no significant differences in length of stay between good and poor preoperative glycaemic control [LOS: P = 0.59 and 0.86 vs P HbA1c vs normal HbA1c was associated with prolonged stay in hospital and in

  1. Race-ethnic differences in the association of genetic loci with HbA1c levels and mortality in U.S. adults: the third National Health and Nutrition Examination Survey (NHANES III

    Directory of Open Access Journals (Sweden)

    Grimsby Jonna L

    2012-04-01

    Full Text Available Abstract Background Hemoglobin A1c (HbA1c levels diagnose diabetes, predict mortality and are associated with ten single nucleotide polymorphisms (SNPs in white individuals. Genetic associations in other race groups are not known. We tested the hypotheses that there is race-ethnic variation in 1 HbA1c-associated risk allele frequencies (RAFs for SNPs near SPTA1, HFE, ANK1, HK1, ATP11A, FN3K, TMPRSS6, G6PC2, GCK, MTNR1B; 2 association of SNPs with HbA1c and 3 association of SNPs with mortality. Methods We studied 3,041 non-diabetic individuals in the NHANES (National Health and Nutrition Examination Survey III. We stratified the analysis by race/ethnicity (NHW: non-Hispanic white; NHB: non-Hispanic black; MA: Mexican American to calculate RAF, calculated a genotype score by adding risk SNPs, and tested associations with SNPs and the genotype score using an additive genetic model, with type 1 error = 0.05. Results RAFs varied widely and at six loci race-ethnic differences in RAF were significant (p ATP11A, the SNP RAF was 54% in NHB, 18% in MA and 14% in NHW (p 1c in NHW (β = 0.012 HbA1c increase per risk allele, p = 0.04 and MA (β = 0.021, p = 0.005 but not NHB (β = 0.007, p = 0.39. The genotype score was not associated with mortality in any group (NHW: OR (per risk allele increase in mortality = 1.07, p = 0.09; NHB: OR = 1.04, p = 0.39; MA: OR = 1.03, p = 0.71. Conclusion At many HbA1c loci in NHANES III there is substantial RAF race-ethnic heterogeneity. The combined impact of common HbA1c-associated variants on HbA1c levels varied by race-ethnicity, but did not influence mortality.

  2. Hb Dartmouth (HBA2: c.200T>C): An α2-Globin Gene Associated with Hb H Disease in One Homozygous Patient.

    Science.gov (United States)

    Farashi, Samaneh; Faramarzi Garous, Negin; Ashki, Mehri; Vakili, Shadi; Zeinali, Fatemah; Imanian, Hashem; Azarkeivan, Azita; Najmabadi, Hossein

    2015-01-01

    Hb H (β4) disease is caused by deletion or inactivation of three out of four α-globin genes. A high incidence of Hb H disease has been reported all over the world. There is a wide spectrum of phenotypic presentations, from clinically asymptomatic to having significant hepatosplenomegaly and requiring occasional or even regular blood transfusions, even more severe anemia, Hb Bart's (γ4) hydrops fetalis syndrome that can cause death in the affected fetuses late in gestation. We here present a case who was diagnosed with Hb H disease that represents a new genotype for this hereditary disorder. Hb Dartmouth is a variant caused by a missense mutation at codon 66 of the α2-globin gene (HBA2: c.200T>C), resulting in the substitution of leucine by proline. We here emphasize the importance of this point mutation involving Hb H disease and also the necessity for prenatal diagnosis (PND) for those who carry this point mutation in the heterozygous state.

  3. Secondary polycythaemia in a Malay girl with homozygous Hb Tak.

    Science.gov (United States)

    Amran, H S; Aziz, M A; George, E; Mahmud, N; Lee, T Y; Md Noor, S

    2017-12-01

    Hb Tak is one of more than 200 high affinity haemoglobin variants reported worldwide. It results from the insertion of two nucleotides (AC) at the termination codon, between codon 146 and codon 147 of the beta-globin gene [Beta 147 (+AC)]. Polycythaemia is the main clinical feature although affected carriers are usually asymptomatic and do not require intervention. Several case studies in this region have reported the co-inheritance of Hb Tak with Hb E, delta beta and beta thalassaemia with one case of homozygous Hb Tak in a Thai boy. In this case report, a cluster of haemoglobin Tak was found in a family of Malay ethnic origin. Cascade family screening was conducted while investigating a 4-year old girl who presented with symptomatic polycythaemia. She had 2 previous Hb analysis done, at 7-month and 2-year-old with the diagnosis of possible Hb Q Thailand and Homozygous Hb D, respectively. Both diagnosis did not fit her clinical presentations. She was plethoric, had reduced exercise tolerance as well as cardiomyopathy. Her parents were consanguineously married and later diagnosed as asymptomatic carriers of Hb Tak. Consequently, re-analysis of the girl's blood sample revealed a homozygous state of Hb Tak. In conclusion, high oxygen affinity haemoglobin like Hb Tak should be considered in the investigation of polycythaemic patients with abnormal Hb analyses. In this case, DNA analysis was crucial in determining the correct diagnosis.

  4. Clinical and hematological response to hydroxyurea in a patient with Hb Lepore/beta-thalassemia.

    Science.gov (United States)

    Rigano, P; Manfré, L; La Galla, R; Renda, D; Renda, M C; Calabrese, A; Calzolari, R; Maggio, A

    1997-05-01

    The possibility of increasing Hb F in vivo using drugs like 5-azacytidine, hydroxyurea, and butyrate has been established. However, in many cases this does not entail an increase in total hemoglobin. We report on a patient with Hb Lepore/beta-thalassemia being treated with hydroxyurea (30 mg/Kg/day) because of the presence of erythroid extramedullary masses with severe neurological abnormalities. During therapy the patient showed a remarkable improvement in neurological signs due to the reduction in extra-medullary masses, a significant increase in both total hemoglobin (from 5.8 to 9.7 g/dl) and Hb F (from 4.9 g/dl to 9.1 g/dl). The marked improvement in hemoglobin level in our patient with Hb Lepore/beta-thalassemia suggests gamma-globin gene activation due to the DNA structure determined by the crossover event.

  5. Intracapillary HbO2 saturations in murine tumours and human tumour xenografts measured by cryospectrophotometry: relationship to tumour volume, tumour pH and fraction of radiobiologically hypoxic cells.

    Science.gov (United States)

    Rofstad, E K; Fenton, B M; Sutherland, R M

    1988-05-01

    Frequency distributions for intracapillary HbO2 saturation were determined for two murine tumour lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) using a cryospectrophotometric method. The aim was to search for possible relationships between HbO2 saturation status and tumour volume, tumour pH and fraction of radiobiologically hypoxic cells. Tumour pH was measured by 31P NMR spectroscopy. Hypoxic fractions were determined from cell survival curves for tumours irradiated in vivo and assayed in vitro. Tumours in the volume range 100-4000 mm3 were studied and the majority of the vessels were found to have HbO2 saturations below 10%. The volume-dependence of the HbO2 frequency distributions differed significantly among the four tumour lines; HbO2 saturation status decreased with increasing tumour volume for the KHT, RIF-1 and MLS lines and was independent of tumour volume for the OWI line. The data indicated that the rate of decrease in HbO2 saturation status during tumour growth was related to the rate of development of necrosis. The volume-dependence of tumour pH was very similar to that of the HbO2 saturation status for all tumour lines. Significant correlations were therefore found between HbO2 saturation status and tumour pH, both within tumour lines and across the four tumour lines, reflecting that the volume-dependence of both parameters probably was a compulsory consequence of reduced oxygen supply conditions during tumour growth. Hypoxic fraction increased during tumour growth for the KHT, RIF-1 and MLS lines and was volume-independent for the OWI line, suggesting a relationship between HbO2 saturation status and hypoxic fraction within tumour lines. However, there was no correlation between these two parameters across the four tumour lines, indicating that the hypoxic fraction of a tumour is not determined only by the oxygen supply conditions; other parameters may also be important, e.g. oxygen diffusivity, rate of oxygen

  6. Heparin-binding epidermal growth factor-like growth factor (HB-EGF) is increased in osteoarthritis and regulates chondrocyte catabolic and anabolic activities

    Science.gov (United States)

    Long, D.L.; Ulici, V.; Chubinskaya, S.; Loeser, R.F.

    2015-01-01

    Objective We determined if the epidermal growth factor receptor ligand HB-EGF is produced in cartilage and if it regulates chondrocyte anabolic or catabolic activity. Methods HB-EGF expression was measured by quantitative PCR using RNA isolated from mouse knee joint tissues and from normal and OA human chondrocytes. Immunohistochemistry was performed on normal and OA human cartilage and meniscus sections. Cultured chondrocytes were treated with fibronectin fragments (FN-f) as a catabolic stimulus and osteogenic protein 1 (OP-1) as an anabolic stimulus. Effects of HB-EGF on cell signaling were analyzed by immunoblotting of selected signaling proteins. MMP-13 was measured in conditioned media, proteoglycan synthesis was measured by sulfate incorporation, and matrix gene expression by quantitative PCR. Results HB-EGF expression was increased in 12-month old mice at 8 weeks after surgery to induce OA and increased amounts of HB-EGF were noted in human articular cartilage from OA knees. FN-f stimulated chondrocyte HB-EGF expression and HB-EGF stimulated chondrocyte MMP-13 production. However, HB-EGF was not required for FN-f stimulation of MMP-13 production. HB-EGF activated the ERK and p38 MAP kinases and stimulated phosphorylation of Smad1 at an inhibitory serine site which was associated with inhibition of OP-1 mediated proteoglycan synthesis and reduced aggrecan (ACAN) but not COL2A1 expression. Conclusion HB-EGF is a new factor identified in OA cartilage that promotes chondrocyte catabolic activity while inhibiting anabolic activity suggesting it could contribute to the catabolic-anabolic imbalance seen in OA cartilage. PMID:25937027

  7. First Cases of Hb Agrinio Described in Patients from the Republic of Macedonia.

    Science.gov (United States)

    Dimishkovska, Marija; Kuzmanovska, Maja; Kocheva, Svetlana; Martinova, Kata; Karanfilski, Oliver; Stojanoski, Zlate; Plaseska-Karanfilska, Dijana

    Previous molecular analyses of α-thalassemia (α-thal) in the Republic of Macedonia have identified the following genetic defects: -α 3.7 (rightward), -(α) 20.5 and - - MED I deletions and Hb Icaria [α142, Term→Lys (α2), HBA2: c.427T>A] and polyadenylation signal (polyA) [AATAAA>AATGAA (α2), HBA2: c.*92A>G] point mutations. Here, we report two unrelated patients from the Romani population in the Republic of Macedonia, homozygotes for the α2-globin gene variant Hb Agrinio [α29(B10)Leu→Pro; HBA2: c.89T>C]. To date, Hb Agrinio has been described only in individuals of Greek, Cypriot and Spanish origin. Both of our patients had early presentation of the disease (3.5 years and 2 months, respectively) with frequent blood transfusions from early infancy. They have a severe intermediate phenotype of thalassemia (Hb H disease) with hemoglobin (Hb) levels of 7.8 and 7.7 g/dL, respectively. Although the HBA2: c.89T>C mutation results in an α + allele, the severe phenotype of the homozygotes is due to the production of hyperunstable α chains that undergo post translational precipitation. This leads to a greater degree of red cell damage and hemolytic anemia. The detection of Hb Agrinio in two unrelated families of Romani ethnic origin, may suggest it is a founder mutation in this population living in the Republic of Macedonia. Considering the severity of the clinical presentation of the homozygotes or compound heterozygotes for this rare Hb variant, a targeted molecular screening for Hb Agrinio mutation carriers should be considered in all patients of Romani ethnic origin with manifested microcytosis.

  8. Hydrops Fetalis Associated with Compound Heterozygosity for Hb Zurich-Albisrieden (HBA2: C.178G > C) and the Southeast Asian (- -SEA/) Deletion.

    Science.gov (United States)

    Yang, Xin; Yan, Jin-Mei; Li, Jian; Xie, Xing-Mei; Zhou, Jian-Ying; Li, Yan; Li, Dong-Zhi

    2016-09-01

    Hb Zurich-Albisrieden [HBA2: c.178G > C; α59(E8)Gly→Arg (α2)] is a rare nondeletional α-thalassemia (α-thal) that results from a nucleotide substitution at codon 59 of the α2-globin gene. In this report, we present a fetus with cardiomegaly, enlarged placenta and increased middle cerebral artery-peak systolic velocity (MCA-PSV) at 25 weeks' gestation. Fetal blood sampling revealed the severe anemia [hemoglobin (Hb) level being 5.5 g/dL] and Hb H (β4) disease-like hematological findings with Hb Bart's (γ4) level of 30.7%. Molecular analysis of the family found that the father was an Hb Zurich-Albisrieden carrier, the mother heterozygous for the - - SEA α 0 -thal deletion, and the fetus was a compound heterozygote for Hb Zurich-Albisrieden and the - - SEA α 0 -thal deletion. Therefore, this was a rare case of Hb Bart's hydrops fetalis associated with Hb Zurich Albisrieden.

  9. Considerations for closure of low-level radioactive waste engineered disposal facilities

    International Nuclear Information System (INIS)

    1992-01-01

    Proper stabilization and closure of low-level radioactive waste disposal facilities require detailed planning during the early stages of facility development. This report provides considerations for host States, compact regions, and unaffiliated States on stabilization and closure of engineered low-level radioactive waste and mixed waste disposal facilities. A time line for planning closure activities, which identifies closure considerations to be addressed during various stages of a facility's development, is presented. Current Federal regulatory requirements and guidance for closure and post-closure are outlined. Significant differences between host State and Federal closure requirements are identified. Design features used as stabilization measures that support closure, such as waste forms and containers, backfill materials, engineered barrier systems, and site drainage systems, are described. These design features are identified and evaluated in terms of how they promote long-term site stability by minimizing water infiltration, controlling subsidence and surface erosion, and deterring intrusion. Design and construction features critical to successful closure are presented for covers and site drainage. General considerations for stabilization and closure operations are introduced. The role of performance and environmental monitoring during closure is described

  10. Evaluation of glycated albumin (GA) and GA/HbA1c ratio for diagnosis of diabetes and glycemic control: A comprehensive review.

    Science.gov (United States)

    Yazdanpanah, Sara; Rabiee, Mohammad; Tahriri, Mohammadreza; Abdolrahim, Mojgan; Rajab, Asadollah; Jazayeri, Hossein E; Tayebi, Lobat

    2017-06-01

    Diabetes Mellitus (DM) is a group of metabolic diseases characterized by chronic high blood glucose concentrations (hyperglycemia). When it is left untreated or improperly managed, it can lead to acute complications including diabetic ketoacidosis and non-ketotic hyperosmolar coma. In addition, possible long-term complications include impotence, nerve damage, stroke, chronic kidney failure, cardiovascular disease, foot ulcers, and retinopathy. Historically, universal methods to measure glycemic control for the diagnosis of diabetes included fasting plasma glucose level (FPG), 2-h plasma glucose (2HP), and random plasma glucose. However, these measurements did not provide information about glycemic control over a long period of time. To address this problem, there has been a switch in the past decade to diagnosing diabetes and its severity through measurement of blood glycated proteins such as Hemoglobin A1c (HbA1c) and glycated albumin (GA). Diagnosis and evaluation of diabetes using glycated proteins has many advantages including high accuracy of glycemic control over a period of time. Currently, common laboratory methods used to measure glycated proteins are high-performance liquid chromatography (HPLC), immunoassay, and electrophoresis. HbA1c is one of the most important diagnostic factors for diabetes. However, some reports indicate that HbA1c is not a suitable marker to determine glycemic control in all diabetic patients. GA, which is not influenced by changes in the lifespan of erythrocytes, is thought to be a good alternative indicator of glycemic control in diabetic patients. Here, we review the literature that has investigated the suitability of HbA1c, GA and GA:HbA1c as indicators of long-term glycemic control and demonstrate the importance of selecting the appropriate glycated protein based on the patient's health status in order to provide useful and modern point-of-care monitoring and treatment.

  11. Alcohol consumption reduces HbA1c and glycated albumin concentrations but not 1,5-anhydroglucitol.

    Science.gov (United States)

    Inada, Shinya; Koga, Masafumi

    2017-11-01

    Background The effect of alcohol consumption on glycaemic control indicators is not well known. In this study, we studied the effect of alcohol consumption on the plasma glucose and glycaemic control indicators in non-diabetic men. Methods The study enrolled 300 non-diabetic men who received a complete medical checkup (age: 52.8 ± 6.5 years, body mass index: 24.4 ± 2.8 kg/m 2 ). The subjects were divided into four groups by the amount of alcohol consumed, and the plasma glucose, HbA1c, glycated albumin (GA) and 1,5-anhydroglucitol (1,5-AG) concentrations of the groups were compared. Results As the level of alcohol consumption increased, significantly high concentrations of fasting plasma glucose (FPG) were observed, and the oral glucose tolerance test 2-h plasma glucose concentrations tended to rise. While no significant effect of alcohol consumption on HbA1c, 1,5-AG, and the 1,5-AG/FPG ratio was observed, the HbA1c/FPG ratio, GA and the GA/FPG ratio exhibited significantly low values as the level of alcohol consumption increased. In stepwise multivariate regression analysis, alcohol consumption was a significant negative independent variable for HbA1c and GA, but not for 1,5-AG. Conclusions As the level of alcohol consumption increased, the plasma glucose concentrations rose, but the HbA1c and GA concentrations were lower compared with the plasma glucose concentrations. These findings suggest that alcohol consumption may reduce HbA1c and GA concentrations, but not 1,5-AG.

  12. HbA1c Identifies Subjects With Prediabetes and Subclinical Left Ventricular Diastolic Dysfunction.

    Science.gov (United States)

    Di Pino, Antonino; Mangiafico, Sarah; Urbano, Francesca; Scicali, Roberto; Scandura, Salvatore; D'Agate, Veronica; Piro, Salvatore; Tamburino, Corrado; Purrello, Francesco; Rabuazzo, Agata Maria

    2017-10-01

    Prediabetes is associated with subclinical cardiac changes associated with heart failure development. We investigated diastolic function and its association with markers of glycation and inflammation related to cardiovascular disease in patients with prediabetes. We focused on individuals with prediabetes identified only by glycated hemoglobin A1c [HbA1c; 5.7% to 6.4% and normal fasting glucose (NFG) and normal glucose tolerance (NGT) after an oral glucose tolerance test (OGTT)]. Cross-sectional study. Departments of Clinical and Experimental Medicine and Cardiology, University of Catania, Catania, Italy. HbA1c, OGTT, Doppler echocardiography, soluble receptor for advanced glycation end products (sRAGEs), and endogenous secretory RAGE (esRAGE) were evaluated. We recruited 167 subjects with NFG/NGT who were stratified according to HbA1c level: controls (HbA1c prediabetes (HbA1c 5.7% to 6.4%). Patients with HbA1c prediabetes (n = 106) showed a lower peak mitral inflow in early diastole (E wave) to late diastolic atrial filling velocity (A wave) ratio (E/A ratio) than controls (n = 61) (1.10 ± 0.24 vs 1.18 ± 0.23; P prediabetes exhibited subclinical cardiac alterations associated with sRAGE, esRAGE, and HbA1c. These subjects would not have been classified as having prediabetes on the basis of fasting glycemia or post-OGTT values. Copyright © 2017 Endocrine Society

  13. Intelligent type sodium level gauge and its graduation calibration facility

    International Nuclear Information System (INIS)

    Chen Daolong; Wang Xuan; Li Xinying; Sun Huiqing; Zhu Jie

    1998-04-01

    The component construction and their performances of the intelligent type sodium level gauge newly-developed and its graduation calibration facility are presented. They can be operated in the temperature limit 100∼550 degree C. Its graduation characteristic calibration test is described. The temperature effect is analyzed. The graduation characteristic equation using the medium temperature as the parameter is given. The calibration errors are analyzed. The measurement system using this sodium level gauge is presented. The tests show that the intelligent type sodium level gauge possesses good linearity. The accurate sodium level measurement data can be obtained by means of its on-line compensation function of the temperature effect. Moreover, it possesses the self-inspection, the electric shutoff protection, the setting of full-scale, the thermocouple breaking alarm, the two upper limits and two lower limits alarms, the standard analog output signal and the digital output signal. Therefore, it is applicable particularly to the instrument, control and protection systems of LMFBR. The basic error of this intelligent type sodium level gauge is +-1.9% of measuring range

  14. Up-regulation of HB-EGF by the COX-2/PGE2 signaling associates with the cisplatin resistance and tumor recurrence of advanced HNSCC.

    Science.gov (United States)

    Yang, Cheng-Chieh; Tu, Hsi-Feng; Wu, Cheng-Hsien; Chang, Hsiu-Chuan; Chiang, Wei-Fan; Shih, Nai-Chia; Lee, Yong-Syu; Kao, Shou-Yen; Chang, Kuo-Wei

    2016-05-01

    When treating advanced HNSCC, a cisplatin-based systemic regimen benefit patient survival. However, chemoresistance will greatly reduce the effectiveness of this approach. The identification of molecules that contribute to cisplatin resistance may potentially improve the survival. Both HB-EGF and COX-2 have been reported to increase cisplatin-resistance. Here, we have focused on the regulation of HB-EGF/COX-2 and their roles in cisplatin resistance. IHC staining was used to measure the expression levels of HB-EGF and COX-2 on the tissue microarray from 43 tissue samples of patients with advanced HNSCC. siRNA, western blot and qRT-PCR were used to dissect the regulation between EGF, Akt, COX-2, PGE2, and cisplatin sensitivity. The correlation between HB-EGF, COX2 and HNSCC progression was analyzed by the receiver operating characteristic (ROC) curve and Kaplan-Meier disease free survival. Patients of advanced HNSCC patients with increased HB-EGF and COX-2 expression have higher tumor recurrent rates that was related to cisplatin resistance. The resistance was mediated via an increased expression of HB-EGF and COX-2. The activation of Akt by either EGF or areca nut extract were able to upregulate COX-2, which would increase the expression of HB-EGF in a PGE2 dependent manner. Inhibition and knockdown of COX-2 resulted in a decrease in HB-EGF. In the tissue samples from HNSCC patients, there was a significant positive correlation between the expression of COX-2 and HB-EGF. Our results suggested that COX-2 and HB-EGF are important in development of HNSCC cisplatin resistance. These findings may help the development of new strategies for overcoming cisplatin resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. LOWRAD 96. Methods and applications of low-level radioactivity measurements. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Fietz, J [ed.; Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    1997-03-01

    The newest developments in the field of low-level radioactivity measurements and new applications for existing and low-level measuring facilities are presented. The contributions mostly were devoted to basic physical aspects and applications of low-level counting. Papers on chemical separation and preparation techniques and on low-level radiation dose determinations were also presented. (DG)

  16. The Effect of Prolonged Glucosamine Usage on HbA1c Levels and New-Onset Diabetes Mellitus in Overweight and Obese Middle-Aged Women

    NARCIS (Netherlands)

    Y.M.M. Gommans (Yvonne); J. Runhaar (Jos); M.L. Jacobs (Marloes); S.M. Bierma-Zeinstra (Sita)

    2017-01-01

    markdownabstract__Objective:__ The aim of the present study was to evaluate the effect of a 2.5-year glucosamine sulfate intervention on hemoglobin A1c (HbA1c) levels and the incidence of new-onset diabetes mellitus over 6.5 years in middle-aged women with a body mass index ≥27 kg/m2.

  17. Application of Six Sigma Model to Evaluate the Analytical Quality of Four HbA1c Analyzers.

    Science.gov (United States)

    Maesa, Jos Eacute M; Fern Aacute Ndez-Riejos, Patricia; S Aacute Nchez-Mora, Catalina; Toro-Crespo, Mar Iacute A De; Gonz Aacute Lez-Rodriguez, Concepci Oacute N

    2017-01-01

    The Six Sigma Model is a global quality management system applicable to the determination of glycated hemoglobin (HbA1c). In addition, this model can ensure the three characteristics influencing the patient risk: the correct performance of the analytical method with low inaccuracy and bias, the quality control strategy used by the laboratory, and the necessary quality of the analyte. The aim of this study is to use the Six Sigma Model for evaluating quality criteria in the determination of glycated hemoglobin HbA1c and its application to assess four different HbA1c analyzers. Four HbA1c analyzers were evaluated: HA-8180V®, D-100®, G8®, and Variant II Turbo®. For 20 consecutive days, two levels of quality control (high and low) provided by the manufacturers were measured in each of the instruments. Imprecision (CV), bias, and Sigma values (σ) were calculated with the data obtained and a method decision chart was developed considering a range of quality requirements (allowable total error, TEa). For a TEa = 3%, HA-8180V = 1.54 σ, D-100 = 1.63 σ, G8 = 2.20 σ, and Variant II Turbo = -0.08 σ. For a TEa = 4%, HA-8180V = 2.34 σ, D-100 = 2.32 σ, G8 = 3.74 σ, and Variant II Turbo = 0.16 σ. For a TEa = 10%, HA8180V = 7.12 σ, D-100 = 6.46 σ, G8 = 13.0 σ, and Variant II Turbo = 1.56 σ. Applying the Stockholm consensus and its subsequent Milan review to the results: the maximum level in quality requirements for HbA1c is an allowable total error (TEa) = 3%, G8 is located in region 2 σ (2.20), which is a poor result, and HA-8180V and D-100 are both in region 1 σ (1.54 and 1.63, respectively), which is an unacceptable analytical performance.

  18. Interaction of Hb Grey Lynn (Vientiane) [α91(FG3)Leu>Phe (α1)] with Hb E [β26(B8) Glu>Lys] and α(+)-thalassemia: Molecular and Hematological Analysis.

    Science.gov (United States)

    Singha, Kritsada; Fucharoen, Goonnapa; Fucharoen, Supan

    2015-01-01

    Hemoglobin (Hb) Grey Lynn is a Hb variant caused by a mutation at codon 91 of α1-globin gene whereas Hb E is a common β-globin chain variant among Southeast Asian population. We report two hitherto undescribed conditions of Hb Grey Lynn found in Thai individuals. The study was done on two unrelated Thai subjects. Hematological parameters were recorded and Hb analysis was carried out using automated Hb analyzers. Mutations were identified by DNA analysis. Hematological features of the patients were compared with those of various forms of Hb Grey Lynn documented previously. Hb and DNA analyses identified a heterozygous Hb Grey Lynn in one patient and a double heterozygous Hb Grey Lynn and Hb E with α(+)-thalassemia in another. Interaction of α(Grey Lynn) with β(E) chains leads to the formation of a new Hb variant, namely the Hb Grey Lynn E (α(GL)2β(E)2), detectable by liquid chromatography (10.3%) but masked by Hb E on capillary electrophoresis. Interaction of these multiple globin gene defects could lead to complex hemoglobinopathies requiring combined analysis with multiple Hb analyzers followed by DNA testing to provide accurate diagnosis of the cases.

  19. Transfusion Associated Peak in Hb HPLC Chromatogram – a Case Report

    Science.gov (United States)

    Jain, Sonal; Dass, Jasmita; Pati, Hara Prasad

    2012-01-01

    High performance liquid chromatography (HPLC) and electrophoresis are commonly used to diagnose various hemoglobinopathies. However, insufficient information about the transfusion history can lead to unexpected and confusing results. We are reporting a case of Juvenile myelomonocytic leukemia (JMML) in which HbHPLC was done to quantify fetal hemoglobin (HbF). The chromatogram showed elevated HbF along with a peak in the HbD window. A transfusion acquired peak was suspected based on the unexpectedly low percentage of HbD and was subsequently confirmed using parental HbHPLC. PMID:22348188

  20. Contemporary risk estimates of three HbA1c variables in relation to heart failure following diagnosis of type 2 diabetes.

    Science.gov (United States)

    Skrtic, Stanko; Cabrera, Claudia; Olsson, Marita; Schnecke, Volker; Lind, Marcus

    2017-03-01

    We evaluated the association between glycaemic control and the risk of heart failure (HF) in a contemporary cohort of persons followed after diagnosis of type 2 diabetes (T2D). Persons with T2D diagnosed between 1998 and 2012 were retrieved from the Clinical Practice Research Data Link in the UK and followed from diagnosis until the event of HF, mortality, drop out from the database due to any other reason, or the end of the study on 1 July 2015. The association between each of three different haemoglobin A 1C (HbA 1c ) metrics and HF was estimated using adjusted proportional hazard models. In the overall cohort (n=94 332), the increased risk for HF per 1% (10 mmol/mol) increase in HbA 1c was 1.15 (95% CI 1.13 to 1.18) for updated mean HbA 1c , and 1.06 (1.04 to 1.07) and 1.06 (1.04 to 1.08) for baseline HbA 1c and updated latest HbA 1c , respectively. When categorised, the hazard risk (HR) for the updated mean HbA 1c in relation to HF became higher than for baseline and updated latest HbA 1c above HbA 1c levels of 9%, but did not differ at lower HbA 1c levels. The updated latest variable showed an increased risk for HbA 1c <6% (42 mmol/mol) of 1.16 (1.07 to 1.25), relative category 6-7%, while the HRs for updated mean and baseline HbA 1c showed no such J-shaped pattern. Hyperglycaemia is still a risk factor for HF in persons with T2D of similar magnitude as in earlier cohorts. Such a relationship exists for current glycaemic levels, at diagnosis and the overall level but the pattern differs for these variables. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Exposure to Household Air Pollution from Biomass-Burning Cookstoves and HbA1c and Diabetic Status among Honduran Women.

    Science.gov (United States)

    Rajkumar, Sarah; Clark, Maggie L; Young, Bonnie N; Benka-Coker, Megan L; Bachand, Annette M; Brook, Robert D; Nelson, Tracy L; Volckens, John; Reynolds, Stephen J; L'Orange, Christian; Good, Nicholas; Koehler, Kirsten; Africano, Sebastian; Osorto Pinel, Anibal B; Peel, Jennifer L

    2018-06-13

    Household air pollution from biomass cookstoves is estimated to be responsible for more than two and a half million premature deaths annually, primarily in low and middle-income countries where cardiometabolic disorders, such as Type II Diabetes, are increasing. Growing evidence supports a link between ambient air pollution and diabetes, but evidence for household air pollution is limited. This cross-sectional study of 142 women (72 with traditional stoves and 70 with cleaner-burning Justa stoves) in rural Honduras evaluated the association of exposure to household air pollution (stove type, 24-hour average kitchen and personal fine particulate matter [PM 2.5 ] mass and black carbon) with glycated hemoglobin (HbA1c) levels and diabetic status based on HbA1c levels. The prevalence ratio [PR] per interquartile range increase in pollution concentration indicated higher prevalence of prediabetes/diabetes (versus normal HbA1c) for all pollutant measures (e.g., PR per 84 μg/m 3 increase in personal PM 2.5 , 1.49; 95% confidence interval [CI], 1.11 - 2.01). Results for HbA1c as a continuous variable were generally in the hypothesized direction. These results provide some evidence linking household air pollution with the prevalence of prediabetes/diabetes, and, if confirmed, suggest that the global public health impact of household air pollution may be broader than currently estimated. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Hb H Hydrops Fetalis Syndrome Caused by Association of the - -(SEA) Deletion and Hb Constant Spring (HBA2: c.427T > C) Mutation in a Chinese Family.

    Science.gov (United States)

    He, Sheng; Zheng, Chenguang; Meng, Dahua; Chen, Rongyu; Zhang, Qiang; Tian, Xiaoxian; Chen, Shaoke

    2015-01-01

    Hb Constant Spring (Hb CS; HBA2: c.427T > C) is an unstable hemoglobin (Hb) variant that results from a nucleotide substitution at the termination codon of the α2-globin gene. Compound heterozygosity for α(0)-thalassemia (α(0)-thal) and Hb CS (- -(SEA)/α(CS)α) results in Hb H/Hb CS disease, which is generally characterized with mild hemolytic anemia, jaundice, and splenomegaly. Here, we describe one case with Hb H/Hb CS disease that presented with fetal anemia and fetal hydrops, known as Hb H (β4) hydrops fetalis. This is the first report of fetal hydrops caused by association of the - -(SEA) deletion and the α(CS)α mutation. Our study highlights the significance of watchful observation using a serial ultrasound method and care of pregnant women who have fetuses found to carry Hb H/Hb CS disease during pregnancy, to guard against the occurrence of fetal hydrops.

  3. Nuclear translocation of the cytoplasmic domain of HB-EGF induces gastric cancer invasion.

    Science.gov (United States)

    Shimura, Takaya; Yoshida, Michihiro; Fukuda, Shinji; Ebi, Masahide; Hirata, Yoshikazu; Mizoshita, Tsutomu; Tanida, Satoshi; Kataoka, Hiromi; Kamiya, Takeshi; Higashiyama, Shigeki; Joh, Takashi

    2012-05-30

    Membrane-anchored heparin-binding epidermal growth factor-like growth factor (proHB-EGF) yields soluble HB-EGF, which is an epidermal growth factor receptor (EGFR) ligand, and a carboxy-terminal fragment of HB-EGF (HB-EGF-CTF) after ectodomain shedding. We previously reported that HB-EGF-CTF and unshed proHB-EGF which has the cytoplasmic domain of proHB-EGF (HB-EGF-C), translocate from the plasma membrane to the nucleus and regulate cell cycle after shedding stimuli. However, the significance of nuclear exported HB-EGF-C in human gastric cancer is unclear. We investigated the relationship between intracellular localization of HB-EGF-C and clinical outcome in 96 gastric cancer patients treated with gastrectomy. Moreover, we established stable gastric cancer cell lines overexpressing wild-type HB-EGF (wt-HB-EGF) and mutated HB-EGF (HB-EGF-mC), which prevented HB-EGF-C nuclear translocation after shedding. Cell motility between these 2 gastric cancer cell lines was investigated using a transwell invasion assay and a wound healing assay. Of the 96 gastric cancer cases, HB-EGF-C immunoreactivity was detected in both the nucleus and cytoplasm in 19 cases (19.8 %) and in the cytoplasm only in 25 cases (26.0 %). The nuclear immunoreactivity of HB-EGF-C was significantly increased in stage pT3/4 tumors compared with pT1/2 tumors (T1/2 vs. T3/4: 11.1 % vs. 36.4 %, P Gastric cancer cell invasion obviously increased in wt-HB-EGF-expressing cells, but invasion in HB-EGF-mC-expressing cells showed a slight increase compared with control cells. Moreover, wt-HB-EGF overexpression increased the effectiveness of wound healing, but had no significant effect in HB-EGF-mC-expressing cells. Both the function of HB-EGF as an EGFR ligand and a novel signal for HB-EGF-C nuclear translocation induce gastric cancer growth, whereas HB-EGF-C nuclear translocation independently plays a critical role in gastric cancer invasion. The present study demonstrated that HB-EGF-C nuclear translocation

  4. Should we adjust erythropoiesis-stimulating agent dosage to postdialysis hemoglobin levels? A pilot study.

    Science.gov (United States)

    Castillo, Nieves; García-García, Patricia; Rivero, Antonio; Jiménez-Sosa, Alejandro; Macía, Manuel; Getino, María Adela; Méndez, María Luisa; García-Pérez, Javier; Navarro-González, Juan F

    2012-07-16

    Predialysis hemoglobin (Hb) may overestimate the true erithropoiesis-stimulating agents (ESA) requirements. We tested whether predialysis Hb is a reliable predictor of the postdialysis level to better control ESA dosage, and evaluated the relation between ESA, Hb and cardiovascular events (CVE). Cohort study including 67 stable hemodialysis patients. Pre- and post-dialysis Hb concentrations were measured, and ESA doses were calculated. A model to predict post-dialysis Hb is proposed. During 18 months follow-up, CVE, hospitalizations and mortality were collected. After dialysis, Hb concentration rise by 6.1 ± 5.6%. Using postdialysis Hb, the weight-adjusted ESA dosage would be lower respect to the prescription using predialysis Hb: 104 ± 120 vs 128 ± 124 U/kg/week (P < 0.001). Using predialysis Hb, 40.2% of subjects had a Hb level above 12 g/dL, whereas this percent increased to 70.1% using postdialysis Hb. During the follow-up, 15 patients had a CVE, without differences in Hb levels respect to subjects without CVE. However, patients with CVE had received higher ESA doses: 186 ± 180 vs 111 ± 98 U/Kg/week (P = 0.001). The prediction model is: Postdialysis Hb (g/dL) = 1.636 + 0.871 x predialysis Hb* (g/dL) + 0.099 x UF rate** (mL/kg/h) - 0.39 for women***. [R2 = 0.74; *P < 0,001; **P = 0.001; ***P = 0.03). Postdialysis Hb can be a better reflect of the real Hb level in hemodialysis patients. Using postdialysis Hb would avoid the use of inappropriately high ESA doses. The prediction of postdialysis Hb with an adjusted model would help us to identify those patients at risk for ESA overdosification.

  5. Environmental monitoring of low-level radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Shum, E.Y.; Starmer, R.J.; Young, M.H.

    1989-12-01

    This branch technical position (BTP) paper on the environmental monitoring program for a low-level radioactive waste disposal facility provides general guidance on what is required by Section 61.53 of Title 10 of the Code of Federal Regulations (10 CFR) of applicants submitting a license application for such a facility. In general, the environmental monitoring program consists of three phases: preoperational, operational, and postoperational. Each phase of the monitoring program should be designed to fulfill the specific objectives defined in the BTP paper. During the preoperational phase, the objectives of the program are to provide site characterization information, to demonstrate site suitability and acceptability, to obtain background or baseline information, and to provide a record for public information. During the operational phase, the emphasis on measurement shifts. Monitoring data are obtained to provide early warning of releases and to document compliance with regulations, the dose limits of 10 CFR Part 61, or applicable standards of the US Environmental Protection Agency. Data are also used to update important pathway parameters to improve predictions of site performance and to provide a record of performance for public information. The postoperational environmental monitoring program emphasizes measurements to demonstrate compliance with the site-closure requirements and continued compliance with the performance objective in regard to the release of radionuclides to the environment. The data are used to support evaluation of long-term effects on the general public and for public information. Guidance is also provided in the BTP paper on the choice of which constituents to measure, setting action levels, relating measurements to appropriate actions in a corrective action plan, and quality assurance

  6. Nuclear translocation of the cytoplasmic domain of HB-EGF induces gastric cancer invasion

    International Nuclear Information System (INIS)

    Shimura, Takaya; Higashiyama, Shigeki; Joh, Takashi; Yoshida, Michihiro; Fukuda, Shinji; Ebi, Masahide; Hirata, Yoshikazu; Mizoshita, Tsutomu; Tanida, Satoshi; Kataoka, Hiromi; Kamiya, Takeshi

    2012-01-01

    Membrane-anchored heparin-binding epidermal growth factor-like growth factor (proHB-EGF) yields soluble HB-EGF, which is an epidermal growth factor receptor (EGFR) ligand, and a carboxy-terminal fragment of HB-EGF (HB-EGF-CTF) after ectodomain shedding. We previously reported that HB-EGF-CTF and unshed proHB-EGF which has the cytoplasmic domain of proHB-EGF (HB-EGF-C), translocate from the plasma membrane to the nucleus and regulate cell cycle after shedding stimuli. However, the significance of nuclear exported HB-EGF-C in human gastric cancer is unclear. We investigated the relationship between intracellular localization of HB-EGF-C and clinical outcome in 96 gastric cancer patients treated with gastrectomy. Moreover, we established stable gastric cancer cell lines overexpressing wild-type HB-EGF (wt-HB-EGF) and mutated HB-EGF (HB-EGF-mC), which prevented HB-EGF-C nuclear translocation after shedding. Cell motility between these 2 gastric cancer cell lines was investigated using a transwell invasion assay and a wound healing assay. Of the 96 gastric cancer cases, HB-EGF-C immunoreactivity was detected in both the nucleus and cytoplasm in 19 cases (19.8 %) and in the cytoplasm only in 25 cases (26.0 %). The nuclear immunoreactivity of HB-EGF-C was significantly increased in stage pT3/4 tumors compared with pT1/2 tumors (T1/2 vs. T3/4: 11.1 % vs. 36.4 %, P < 0.01). The growth of wt-HB-EGF- and HB-EGF-mC-expressing cells significantly increased compared with control cells, but the growth of HB-EGF-mC-expressing cells was significantly decreased compared with wt-HB-EGF-expressing cells. Gastric cancer cell invasion obviously increased in wt-HB-EGF-expressing cells, but invasion in HB-EGF-mC-expressing cells showed a slight increase compared with control cells. Moreover, wt-HB-EGF overexpression increased the effectiveness of wound healing, but had no significant effect in HB-EGF-mC-expressing cells. Both the function of HB-EGF as an EGFR ligand and a novel signal for

  7. Nuclear translocation of the cytoplasmic domain of HB-EGF induces gastric cancer invasion

    Science.gov (United States)

    2012-01-01

    Background Membrane-anchored heparin-binding epidermal growth factor-like growth factor (proHB-EGF) yields soluble HB-EGF, which is an epidermal growth factor receptor (EGFR) ligand, and a carboxy-terminal fragment of HB-EGF (HB-EGF-CTF) after ectodomain shedding. We previously reported that HB-EGF-CTF and unshed proHB-EGF which has the cytoplasmic domain of proHB-EGF (HB-EGF-C), translocate from the plasma membrane to the nucleus and regulate cell cycle after shedding stimuli. However, the significance of nuclear exported HB-EGF-C in human gastric cancer is unclear. Methods We investigated the relationship between intracellular localization of HB-EGF-C and clinical outcome in 96 gastric cancer patients treated with gastrectomy. Moreover, we established stable gastric cancer cell lines overexpressing wild-type HB-EGF (wt-HB-EGF) and mutated HB-EGF (HB-EGF-mC), which prevented HB-EGF-C nuclear translocation after shedding. Cell motility between these 2 gastric cancer cell lines was investigated using a transwell invasion assay and a wound healing assay. Results Of the 96 gastric cancer cases, HB-EGF-C immunoreactivity was detected in both the nucleus and cytoplasm in 19 cases (19.8 %) and in the cytoplasm only in 25 cases (26.0 %). The nuclear immunoreactivity of HB-EGF-C was significantly increased in stage pT3/4 tumors compared with pT1/2 tumors (T1/2 vs. T3/4: 11.1 % vs. 36.4 %, P HB-EGF- and HB-EGF-mC-expressing cells significantly increased compared with control cells, but the growth of HB-EGF-mC-expressing cells was significantly decreased compared with wt-HB-EGF-expressing cells. Gastric cancer cell invasion obviously increased in wt-HB-EGF-expressing cells, but invasion in HB-EGF-mC-expressing cells showed a slight increase compared with control cells. Moreover, wt-HB-EGF overexpression increased the effectiveness of wound healing, but had no significant effect in HB-EGF-mC-expressing cells. Conclusions Both the function of HB-EGF as an EGFR ligand

  8. Biochemical and Molecular Analysis of the Hb Lepore Boston Washington in a Syrian Homozygous Child

    Directory of Open Access Journals (Sweden)

    Monica Pirastru

    2017-01-01

    Full Text Available Hemoglobin (Hb Lepore is composed of two normal α chains and two δβ fusion globins that arise from unequal crossover events between the δ- and β-globin genes. The Hb Lepore is widespread all over the world and in many ethnic groups. It includes some of the few clinically significant Hb variants that are associated with a β-thalassemia phenotype. Here, we describe the first occurrence of Hb Lepore Boston Washington in a Syrian individual. The patient, a 10-year-old child, shows severe anemia with a Hb level of 6.85 g/dL and typical thalassemic red cell indices. The diagnostic procedure implies hematological, biochemical, and molecular analysis, including multiplex ligation-dependent probe amplification (MLPA assay, GAP-PCR, and DNA sequencing. This latter allowed us to define the correct structure of the hybrid δβ-globin gene. The knowledge of the spectrum of mutations associated with different geographical areas is the prerequisite to set up large-scale screening programs and be able to offer genetic counseling to couples at risk.

  9. Measurement of C-14 distribution in forest around nuclear facilities

    International Nuclear Information System (INIS)

    Atarashi-Andoh, Mariko; Amano, Hikaru; Arakhatoon, Jahan

    2003-01-01

    A simple analytical method of C-14 measurement using fast bomb combustion and liquid scintillation counting (LSC) has been developed for measuring C-14 distribution in the terrestrial environment. Specific activities of C-14 in cedar leaves and soils collected from an area around nuclear facilities and control areas were measured using this method. Depth distribution of Cs-137 in soils was also measured at the same sampling sites and compared with the depth distribution of C-14. C-14 specific activity in cedar leaves examined around nuclear facilities exceeded that in the control areas by 8 to 30 mBq (g carbon) -1 . The depth distribution of C-14 in forest soil shows that C-14 has peak values in the top 10 cm of the soil profiles ascribed to the highest bomb C-14 level in the 1960's. The data were made available to assess the behavior of fallout C-14 in the surface environment. (author)

  10. Hb Heathrow [β103(G5)Phe→Leu], a First Report in an Asian Patient with Erythrocytosis.

    Science.gov (United States)

    Shin, Sang Yong; Kim, Hyun Young; Kim, Hee Jin; Kim, Hoon Gu

    2017-05-01

    Congenital erythrocytosis (CE) is a rare and heterogeneous disease. The high oxygen affinity hemoglobin (Hb) variants are the most common cause of CE. Herein, we report a Korean patient with isolated erythrocytosis. A 25-year-old man was referred to our hospital for evaluation of high Hb level (Hb 20.4 g/dL, hematocrit 58%, reticulocyte count 2.90%, white blood cell count 6.83×10⁹/L, and platelet count 195×10⁹/L). Bone marrow biopsy revealed normocellular marrow without myeloproliferative features. JAK2 (V617F, exon 12), CALR (exon 9), and MPL W515K/L mutations were not detected. P₅₀ (partial pressure at which Hb is half saturated with oxygen), which is an indicator of left-shift of oxygen dissociation curve (high oxygen affinity state), was 14.3 mm Hg (reference value 22.6-29.4 mm Hg). He was suspected to have CE. Mutation analysis of the HBB gene revealed the known Hb variant, Hb Heathrow [β103(G5)Phe→Leu]. This is the first report of Hb Heathrow in Asian. © Copyright: Yonsei University College of Medicine 2017.

  11. Environmental exposure measurements in and around the site of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Moriuchi, S [Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

    1977-04-01

    Problems in measurement of ..gamma..-ray in environment generated by an operation of nuclear facilities, and practical measurement methods were given an outline. /sup 85/Kr and /sup 133/Xe were mentioned as main nuclides which were released from various kinds of atomic piles for commercial business or research. Problems in measurement of low level ..gamma..-ray by measurement instruments such as a ionizing chamber, NaI (TL) detector, GM counter, and TLD were mentioned. Measurement of accumulated dose with TLD was described, and the change with a progress of time in the measurement objects (..gamma..-ray, fallout ..gamma..-ray, and plume ..gamma..-ray in nature) and its characteristic patterns were showed. Information which were used for identification of minute components in facilities and natural radiation, and method for identification were described. Last, comparison of results of dose measurements and values estimated by calculation was described, and importance of storage of monitoring data was described.

  12. Radiocarbon signal of a low and intermediate level radioactive waste disposal facility in nearby trees.

    Science.gov (United States)

    Janovics, R; Kelemen, D I; Kern, Z; Kapitány, S; Veres, M; Jull, A J T; Molnár, M

    2016-03-01

    Tree ring series were collected from the vicinity of a Hungarian radioactive waste treatment and disposal facility and from a distant control background site, which is not influenced by the radiocarbon discharge of the disposal facility but it represents the natural regional (14)C level. The (14)C concentration of the cellulose content of tree rings was measured by AMS. Data of the tree ring series from the disposal facility was compared to the control site for each year. The results were also compared to the (14)C data of the atmospheric (14)C monitoring stations at the disposal facility and to international background measurements. On the basis of the results, the excess radiocarbon of the disposal facility can unambiguously be detected in the tree from the repository site. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Investigation of local heterogeneity of hbO2 and hb in working dog heart in situ under isovolemic hemodilution and critical coronary stenosis

    Science.gov (United States)

    Krug, Alfons; Kessler, Manfred D.; Khuri, Raja; Lust, Robert; Chitwood, Randolph

    1996-12-01

    A tissue spectrophotometer (EMPHO II) working with 70 micrometer micro lightguide sensors enables recording of spectra in the visible wavelength range (500 - 630 nm). During an initial period arterial hypoxia and hyperoxia were induced on working dog heart by mechanical ventilation with oxygen fractions (fiO2) of 0.1 and 0.5. Under these conditions the effects of low and high fiO2 on oxygenation distribution of intracapillary hemoglobin were investigated. In the second part of the experiment the relation between systemic hematocrit, local hemoglobin concentration, local hemoglobin oxygenation and the oxygen regulation mechanism were studied in detail. In the final part of the experiment the effect of critical coronary stenosis on hb and hbO2 was measured. Critical stenosis was achieved by partial clamping of the left anterior coronary artery (LAD).

  14. A pilot interventional study to evaluate the impact of cholecalciferol treatment on HbA1c in type 1 diabetes (T1D

    Directory of Open Access Journals (Sweden)

    R Perchard

    2017-05-01

    Full Text Available Background: Higher 25(OHD3 levels are associated with lower HbA1c, but there are limited UK interventional trials assessing the effect of cholecalciferol on HbA1c. Aims: (1 To assess the baseline 25(OHD3 status in a Manchester cohort of children with type 1 diabetes (T1D. (2 To determine the effect of cholecalciferol administration on HbA1c. Methods: Children with T1D attending routine clinic appointments over three months in late winter/early spring had blood samples taken with consent. Participants with a 25(OHD3 level 10 years units. HbA1c levels before and after treatment were recorded. Results: Vitamin D levels were obtained from 51 children. 35 were Caucasian, 11 South Asian and 5 from other ethnic groups. 42 were vitamin D deficient, but 2 were excluded from the analysis. All South Asian children were vitamin D deficient, with mean 25(OHD3 of 28 nmol/L. In Caucasians, there was a negative relationship between baseline 25(OHD3 level and HbA1c (r = −0.484, P < 0.01. In treated participants, there was no significant difference in mean HbA1c at 3 months (t = 1.010, P = 0.328 or at 1 year (t = −1.173, P = 0.248 before and after treatment. One-way ANCOVA, controlling for age, gender, ethnicity, BMI and diabetes duration showed no difference in Δ HbA1c level. Conclusion: We report important findings at baseline, but in children treated with a stat dose of cholecalciferol, there was no effect on HbA1c. Further studies with larger sample sizes and using maintenance therapy are required.

  15. C-Peptide Level in Fasting Plasma and Pooled Urine Predicts HbA1c after Hospitalization in Patients with Type 2 Diabetes Mellitus.

    Directory of Open Access Journals (Sweden)

    Remi Sonoda

    Full Text Available In this study, we investigate how measures of insulin secretion and other clinical information affect long-term glycemic control in patients with type 2 diabetes mellitus. Between October 2012 and June 2014, we monitored 202 diabetes patients who were admitted to the hospital of Asahi Life Foundation for glycemic control, as well as for training and education in diabetes management. We measured glycated hemoglobin (HbA1c six months after discharge to assess disease management. In univariate analysis, fasting plasma C-peptide immunoreactivity (F-CPR and pooled urine CPR (U-CPR were significantly associated with HbA1c, in contrast to ΔCPR and C-peptide index (CPI. This association was strongly independent of most other patient variables. In exploratory factor analysis, five underlying factors, namely insulin resistance, aging, sex differences, insulin secretion, and glycemic control, represented patient characteristics. In particular, insulin secretion and resistance strongly influenced F-CPR, while insulin secretion affected U-CPR. In conclusion, the data indicate that among patients with type 2 diabetes mellitus, F-CPR and U-CPR may predict improved glycemic control six months after hospitalization.

  16. Nuclear translocation of the cytoplasmic domain of HB-EGF induces gastric cancer invasion

    Directory of Open Access Journals (Sweden)

    Shimura Takaya

    2012-05-01

    Full Text Available Abstract Background Membrane-anchored heparin-binding epidermal growth factor-like growth factor (proHB-EGF yields soluble HB-EGF, which is an epidermal growth factor receptor (EGFR ligand, and a carboxy-terminal fragment of HB-EGF (HB-EGF-CTF after ectodomain shedding. We previously reported that HB-EGF-CTF and unshed proHB-EGF which has the cytoplasmic domain of proHB-EGF (HB-EGF-C, translocate from the plasma membrane to the nucleus and regulate cell cycle after shedding stimuli. However, the significance of nuclear exported HB-EGF-C in human gastric cancer is unclear. Methods We investigated the relationship between intracellular localization of HB-EGF-C and clinical outcome in 96 gastric cancer patients treated with gastrectomy. Moreover, we established stable gastric cancer cell lines overexpressing wild-type HB-EGF (wt-HB-EGF and mutated HB-EGF (HB-EGF-mC, which prevented HB-EGF-C nuclear translocation after shedding. Cell motility between these 2 gastric cancer cell lines was investigated using a transwell invasion assay and a wound healing assay. Results Of the 96 gastric cancer cases, HB-EGF-C immunoreactivity was detected in both the nucleus and cytoplasm in 19 cases (19.8 % and in the cytoplasm only in 25 cases (26.0 %. The nuclear immunoreactivity of HB-EGF-C was significantly increased in stage pT3/4 tumors compared with pT1/2 tumors (T1/2 vs. T3/4: 11.1 % vs. 36.4 %, P  Conclusions Both the function of HB-EGF as an EGFR ligand and a novel signal for HB-EGF-C nuclear translocation induce gastric cancer growth, whereas HB-EGF-C nuclear translocation independently plays a critical role in gastric cancer invasion. The present study demonstrated that HB-EGF-C nuclear translocation might be crucial in gastric cancer invasion. HB-EGF-C nuclear translocation may offer a prognostic marker and a new molecular target for gastric cancer therapy.

  17. Should we adjust erythropoiesis-stimulating agent dosage to postdialysis hemoglobin levels? A pilot study

    OpenAIRE

    Castillo Nieves; García-García Patricia; Rivero Antonio; Jiménez-Sosa Alejandro; Macía Manuel; Getino María; Méndez María; García-Pérez Javier; Navarro-González Juan F

    2012-01-01

    Abstract Background Predialysis hemoglobin (Hb) may overestimate the true erithropoiesis-stimulating agents (ESA) requeriments. We tested whether predialysis Hb is a reliable predictor of the postdialysis level to better control ESA dosage, and evaluated the relation between ESA, Hb and cardiovascular events (CVE). Methods Cohort study including 67 stable hemodialysis patients. Pre- and post-dialysis Hb concentrations were measured, and ESA doses were calculated. A model to predict post-dialy...

  18. Serum Levels of sRAGE Are Associated with Body Measurements, but Not Glycemic Parameters in Patients with Prediabetes.

    Science.gov (United States)

    Guclu, Metin; Ali, Asuman; Eroglu, Derya Ustun; Büyükuysal, Sema Oral; Cander, Soner; Ocak, Nihal

    2016-02-01

    Our aim was to assess serum levels of the soluble receptor for advanced glycation end products (sRAGE) and to examine their association with anthropometric and metabolic parameters in patients with prediabetes and obese controls. The two study groups were composed of 42 patients with prediabetes and diabetic neuropathy and 42 age-, gender-, body weight (BW)-, and body mass index (BMI)-matched obese adults as the control group. Prediabetes was diagnosed by the following criteria issued by the American Diabetes Association: impaired fasting glucose [fasting plasma glucose (FPG) level of 100-125 mg/dL], impaired glucose tolerance (2 hr plasma glucose level of 140-199 mg/dL after a 75 grams oral glucose challenge), or a glycated hemoglobin (HbA1C) level of 5.7%-6.4%. There were no differences between the groups in terms of age, gender distribution, BW, or BMI. Despite these similarities, patients with prediabetes had higher FPG, HbA1c, and 2-hr postchallenge glucose levels, higher systolic and diastolic blood pressure, and larger waist and hip circumferences compared with the obese controls. Lipid measurements, complete blood counts, kidney and liver function tests, high-sensitivity C-reactive protein, and sRAGE levels were similar between the two groups. We found significant negative correlations between sRAGE levels and BW, BMI, waist and hip circumferences, waist-to-hip ratios, and low-density lipoprotein (LDL) cholesterol levels. There were no significant correlations with other parameters, including demographic, metabolic, and blood pressure measurements. In contrast to glycemic parameters, serum levels of sRAGE were negatively correlated with body measurements indicative of obesity in the prediabetic state. In addition, the negative correlation with LDL cholesterol levels suggests that sRAGE has a more robust association with metabolic syndrome than with prediabetes.

  19. Aircraft Horizontal Thrust Measurement Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is designed to support the DoD mission by providing unique air vehicle installed engine performance (thrust output) measurements. This system consists...

  20. Inequality in the hepatitis B awareness level in rural residents from 7 provinces in China.

    Science.gov (United States)

    Zheng, Juan; Li, Quan; Wang, Jian; Zhang, Guojie; Wangen, Knut R

    2017-05-04

    The hepatitis B (HB) awareness level is an important factor affecting the rates of HB virus vaccination. To better understand income-related inequalities in the HB awareness level, it is imperative to identify the sources of inequalities and assess the contribution rates of these influential factors. This study analyzed the unequal distribution of the HB awareness level and the contributions of various influential factors. We performed a cross-sectional household survey with questionnaire-based, face-to-face interviews in 7 Chinese provinces. Responses from 7271 respondents were used in this analysis. Multinomial logistic regression was used for the analysis of contributing factors, and the concentration index was used as a measure of HB awareness inequalities. The HB awareness level varied across participants with different characteristics. Multinomial logistic regression of the explanatory factors of the HB awareness level showed that several estimated coefficients and relative risk ratios were statistically significant for middle- and high-level awareness, except for sex, occupation, and household income. The concentration index of the HB knowledge score was 0.140, indicating inequality gradients disadvantageous to the poor. The contribution rate of socioeconomic factors was the largest (60.8%), followed by demographic characteristics (29.0%) and geographic factors (4.3%). Demographic, socioeconomic, and geographic factors are associated with the HB awareness inequality. Therefore, to reduce inequality, HB-related health education targeting individuals with low socioeconomic status should be performed. Less-developed provinces, especially with high proportions of poor residents, warrant particular attention. Our findings may be beneficial to improve the HB virus vaccination rate for individuals with low socioeconomic status.

  1. The optical emission from the supernova remnant HB 3

    Science.gov (United States)

    Fesen, R. A.; Gull, T. R.

    1983-01-01

    The supernova remnant HB 3 was first detected as a radio source by Brown and Hazard (1953). On the basis of subsequent radio studies, it was concluded that the object was a supernova remnant (SNR). HB 3 is located at the far western edge of the H II region/molecular cloud complex W3-W4-W5 (IC 1795-1805-1848). However, a physical association of HB 3 with this complex is uncertain. In the present investigation, attention is called to the probability that HB 3 exhibits a more extensive optical emission structure than previously realized, and one which agrees well with both the position and morphology of the radio emission. It is found that narrow-passband optical images strongly suggest an almost complete optical emission shell for HB 3. Spectroscopic observations are, however, required to confirm that this emission is characteristic of a SNR.

  2. Change in Sedentary Time, Physical Activity, Bodyweight, and HbA1c in High-Risk Adults.

    Science.gov (United States)

    McCarthy, Matthew; Edwardson, Charlotte L; Davies, Melanie J; Henson, Joseph; Gray, Laura; Khunti, Kamlesh; Yates, Thomas

    2017-06-01

    In recent years, there has been a migration toward the use of glycated hemoglobin (HbA1c) in determining glycemic control. This study aimed to quantify the associations between changes in body weight, sedentary time, and moderate to vigorous physical activity (MVPA) time with HbA1c levels for a 3-yr period among adults at high risk of type 2 diabetes. This study reports baseline and 3-yr follow-up data from the Walking Away from Type 2 Diabetes study. ActiGraph GT3X accelerometers captured sedentary time and MVPA. Linear regression examined the independent associations of changes in sedentary time, MVPA, and body weight with HbA1c between baseline and 3-yr follow-up. The sample composed of 489 participants (mean age = 64.2 ± 7.3 yr, body mass index = 31.7 ± 5.1, 63.4% male) with valid baseline and follow-up accelerometer, body weight, and HbA1c data. After adjustment for known confounders, an increase in MVPA time (per 30 min·d) was associated with a decrease in HbA1c percentage (β = -0.11 [-0.18 to -0.05], P = 0.001), and an increase in body weight (per 6 kg) was associated with an increase in HbA1c percentage (β = 0.08 [0.04-0.12], P HbA1c ≥ 6.0%) strengthened these associations (P HbA1c after adjustment for change in MVPA time. Increases in MVPA and body weight were associated with a reduction and increase in HbA1c, respectively, particularly in those with dysglycemia. Quantifying the effect that health behavior changes have on HbA1c can be used to inform prevention programs.

  3. Facility factors dominate the ability to achieve target haemoglobin levels in haemodialysis patients.

    Science.gov (United States)

    Chan, Kevin E; Lafayette, Richard A; Whittemore, Alice S; Hlatky, Mark A; Moran, John

    2008-09-01

    Our objective was to determine whether patient factors, processes of care and measures of erythropoietin (EPO) responsiveness were associated with successful anemia management at the individual patient level. We retrospectively reviewed laboratory and demographic data from 1499 patients receiving hemodialysis in 15 units operated by the same dialysis provider. We performed univariate and multivariate logistic regression analysis to determine predictors of an average 3-month hemoglobin level below or above the target interval of 11.0-12.5 g/dL. To explain the effect of facility on anemia performance, we calculated correlations between measures of EPO responsiveness and the probability of achieving the target interval by facility. Patients above the target hemoglobin range demonstrated an association with parathyroid hormone (PTH) (OR = 0.96 per 100 pg/mL increase), female gender (OR = 0.68), EPO protocol use (OR = 0.94 per 10% increase in use) and facility (range of OR = 0.26-2.59 for 15 participating sites). Patients below the target hemoglobin range demonstrated an association with CRP (OR = 1.10 per mg/L increase), PTH (OR = 1.07 per 100 pg/mL increase), iron deficiency (OR = 1.07 per 10% increase), EPO protocol use (OR = 0.89 per 10% increase in use), iron protocol use (OR = 0.93 per 10% increase in use) and facility (range of OR = 0.58-3.41 over 15 units). EPO index (r = 0.71), EPO dose (r = 0.73), hemoglobin (r = -0.60) and EPO per unit weight (r = 0.76) were significantly correlated with the probability of achieving the target hemoglobin by facility. The facility significantly influences the outcome of anemia management in patients with ESRD. In part, this is due to the patients' EPO responsiveness, which may be influenced by facility care patterns.

  4. HbA1c and the Prediction of Type 2 Diabetes in Children and Adults.

    Science.gov (United States)

    Vijayakumar, Pavithra; Nelson, Robert G; Hanson, Robert L; Knowler, William C; Sinha, Madhumita

    2017-01-01

    Long-term data validating glycated hemoglobin (HbA 1c ) in assessing the risk of type 2 diabetes in children are limited. HbA 1c , fasting plasma glucose (FPG), and 2-h postload plasma glucose (2hPG) concentrations were measured in a longitudinal study of American Indians to determine their utility in predicting incident diabetes, all of which is thought to be type 2 in this population. Incident diabetes (FPG ≥126 mg/dL [7.0 mmol/L], 2hPG ≥200 mg/dL [11.1 mmol/L], HbA 1c ≥6.5% [8 mmol/mol], or clinical diagnosis) was determined in 2,095 children without diabetes ages 10-19 years monitored through age 39, and in 2,005 adults ages 20-39 monitored through age 59. Areas under the receiver operating characteristic (ROC) curve for HbA 1c , FPG, and 2hPG in predicting diabetes within 10 years were compared. During long-term follow-up of children and adolescents who did not initially have diabetes, the incidence rate of subsequent diabetes was fourfold (in boys) as high and more than sevenfold (in girls) as high in those with HbA 1c ≥5.7% as in those with HbA 1c ≤5.3%-greater rate ratios than experienced by adults in the same HbA 1c categories. Analyses of ROCs revealed no significant differences between HbA 1c , FPG, and 2hPG in sensitivity and specificity for identifying children and adolescents who later developed diabetes. HbA 1c is a useful predictor of diabetes risk in children and can be used to identify prediabetes in children with other type 2 diabetes risk factors with the same predictive value as FPG and 2hPG. © 2017 by the American Diabetes Association.

  5. Onsite storage facility for low level radwaste

    International Nuclear Information System (INIS)

    Maxwell, M.G.

    1984-01-01

    The Tennessee Valley Authority (TVA) has designed and constructed an onsite storage facility for low level radwaste (LLRW) at its Browns Ferry Nuclear Plant in northern Alabama. The paper addresses the function of this facility and provides a complete description of the reinforced concrete storage modules which are the principal structural elements of the facility. The loads and loading combinations for the design of the storage modules are defined to include the foundation design parameters. Other aspects of the modules that are addressed are; the structural roof elements that provide access to the modules, shielding requirements for the LLRW, and tornado missile considerations

  6. The significance of disulfide bonding in biological activity of HB-EGF, a mutagenesis approach

    International Nuclear Information System (INIS)

    Hoskins, J.T.; Zhou, Z.; Harding, P.A.

    2008-01-01

    A site-directed mutagenesis approach was taken to disrupt each of 3 disulfide bonds within human HB-EGF by substituting serine for both cysteine residues that contribute to disulfide bonding. Each HB-EGF disulfide analogue (HB-EGF-Cys/Ser 108/121 , HB-EGF-Cys/Ser 116/132 , and HB-EGF-Cys/Ser 134/143 ) was cloned under the regulation of the mouse metallothionein (MT) promoter and stably expressed in mouse fibroblasts. HB-EGF immunoreactive proteins with M r of 6.5, 21 and 24 kDa were observed from lysates of HB-EGF and each HB-EGF disulfide analogue. HB-EGF immunohistochemical analyses of each HB-EGF stable cell line demonstrated ubiquitous protein expression except HB-EGF-Cys/Ser 108/121 and HB-EGF-Cys/Ser 116/132 stable cell lines which exhibited accumulated expression immediately outside the nucleus. rHB-EGF, HB-EGF, and HB-EGF 134/143 proteins competed with 125 I-EGF in an A431 competitive binding assay, whereas HB-EGF-Cys/Ser 108/121 and HB-EGF-Cys/Ser 116/132 failed to compete. Each HB-EGF disulfide analogue lacked the ability to stimulate tyrosine phosphorylation of the 170 kDa EGFR. These results suggest that HB-EGF-Cys/Ser 134/143 antagonizes EGFRs

  7. Carboxyhemoglobin and methemoglobin levels as prognostic markers in acute pulmonary embolism.

    Science.gov (United States)

    Kakavas, Sotirios; Papanikolaou, Aggeliki; Ballis, Evangelos; Tatsis, Nikolaos; Goga, Christina; Tatsis, Georgios

    2015-04-01

    Carboxyhemoglobin (COHb) and methemoglobin (MetHb) levels have been associated with a poor outcome in patients with various pathological conditions including cardiovascular diseases. Our aim was to retrospectively assess the prognostic value of arterial COHb and MetHb in patients with acute pulmonary embolism (PE). We conducted a retrospective study of 156 patients admitted in a pulmonary clinic due to acute PE. Measured variables during emergency department evaluation that were retrospectively analyzed included the ratio of the partial pressure of oxygen in arterial blood to the fraction of oxygen in inspired gas, Acute Physiology and Chronic Health Evaluation II score, risk stratification indices, and arterial blood gases. The association between arterial COHb and MetHb levels and disease severity or mortality was evaluated using bivariate tests and logistic regression analysis. Arterial COHb and MetHb levels correlated with Acute Physiology and Chronic Health Evaluation II and pulmonary severity index scores. Furthermore, arterial COHb and MetHb levels were associated with troponin T and N-terminal pro-B-type natriuretic peptide levels. In univariate logistic regression analysis, COHb and MetHb levels were both significantly associated with an increased risk of death. However, in multivariate analysis, only COHb remained significant as an independent predictor of in-hospital mortality. Our preliminary data suggest that arterial COHb and MetHb levels reflect the severity of acute PE, whereas COHb levels are independent predictors of in hospital death in patients in this clinical setting. These findings require further prospective validation. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. The impact of ambient temperature on HbA1c in Taiwanese type 2 diabetic patients: The most vulnerable subgroup.

    Science.gov (United States)

    Tien, Kai-Jen; Yang, Chwen-Yi; Weng, Shih-Feng; Liu, Su-Yen; Hsieh, Ming-Chia; Chou, Chien-Wen

    2016-05-01

    The relationship between temperature variability and HbA1c has been reported in Caucasians, but not for Asians of Taiwanese origin. This study investigated the impact of temperature on HbA1c in various groups of Taiwanese with type 2 diabetes in Taiwan. For this longitudinal follow-up study which started in 2006, we recruited a total of 4399 patients with type 2 diabetes who had been regularly followed up at Chi Mei Medical Center and obtained local temperature data for 2006 to 2011 from Taiwan's Central Weather Bureau. We used a generalized estimated equation (GEE) to analyze the HbA1c level and its change over time with temperature and temperature changes, respectively. We found a negative correlation between HbA1c and temperature (R = -0.475, p = 0.001). For every 1°C decrement in temperature, there was an increase in the risk of having a HbA1c level >7% [p HbA1c > 7% among those in the lowest quartile of temperatures than the highest quartile (p = 0.0038, adjusted OR: 1.13). Patients with diabetic patients were at higher risk of HbA1C > 7% in the winter and spring than those in the summer (adjusted OR: 1.13, p = 0.0027; adjusted OR: 1.14, p = 0.0022). After adjusting for various confounders, we found people who were younger than 65 years old, people who had diabetes for longer than 6 years, and people who had a body mass index (BMI) HbA1c levels in Taiwanese people with type 2 diabetes, especially in people under 65 years old, people with diabetes for longer than 6 years, and those with a BMI < 24. Copyright © 2015. Published by Elsevier B.V.

  9. Gas Generation during Sodium Permanganate Addition to HB-Line Phase II Filtrate Tank

    International Nuclear Information System (INIS)

    Hill, B.C.

    2002-01-01

    HB-Line Phase II process requires the addition of sodium permanganate followed by a sodium nitrite addition to prevent the precipitation of plutonium solids in a non-geometrically safe vessel. Previous experimental work has shown this method effective. Current concerns are related to the gas generated by the reaction. Potential difficulties include tank over-pressurization and tank overflow due to foaming or eructation. It is also necessary to verify that the quantity of permanganate specified by the facility is sufficient to reach the desired endpoint in a single addition

  10. Effect of exhaust emissions on carbon monoxide levels in employees working at indoor car wash facilities.

    Science.gov (United States)

    Topacoglu, H; Katsakoglou, S; Ipekci, A

    2014-01-01

    Exhaust emissions from motor vehicles threaten the environment and human health. Carbon monoxide (CO) poisoning, especially the use of exhaust gas CO in suicidal attempts is well known in the literature. Recently, indoor car wash facilities established in large shopping malls with closed parking, lots is a new risk area that exposes car wash employees to prolonged periods of high level CO emissions from cars. The aim of this study was to investigate how carboxyhemoglobin (COHb) blood levels of employees get affected in confined areas with relatively poor air circulation. Twenty male volunteers working in indoor parking car wash facilities were included in the study. Participants were informed about the aim of this study and their consent was obtained. Their pulse COHb levels were measured twice, at the beginning and at the end of the working day using Rad-57 pulse CO-oximeter device, allowing non-invasive measurement of COHb blood levels to compare the changes in their COHb levels before and after work. The mean age of the male volunteers was 29.8 ± 11.9 (range 18-55). While the mean COHb levels measured at the start of the working day was 2.1 ± 2.0 (range 0-9), it was increased to 5.2 ± 3.3 (range 1-15) at the end of work shift (Wilcoxon test, p car wash facility employees is directly impacted and gets elevated by motor vechile exhaust emissions. For the health of the employees at indoor parking car wash facilities, stricter precautions are needed and the government should not give permit to such operations.

  11. Complex Interaction of Hb Q-Thailand (HBA1: c.223G>C) with β-Thalassemia/Hb E (HBB: c.79G>A) Disease.

    Science.gov (United States)

    Panyasai, Sitthichai; Satthakarn, Surada; Pornprasert, Sakorn

    2018-01-01

    Hb Q-Thailand [α74(EF3)Asp→His (α1), GAC>CAC, HBA1: c.223G>C] is an abnormal hemoglobin (Hb) frequently found in Thailand and Southeast Asian countries. The association of the α Q-Thailand allele with other globin gene disorders has important implications in diagnosis. Here, we report how to diagnose the coinheritance of Hb Q-Thailand with β-thalassemia (β-thal)/Hb E disease in four Thai samples from high performance liquid chromatography (HPLC) and capillary electrophoresis (CE) testing results. Understanding of the HPLC chromatogram and CE electropherogram patterns of this complex mutation is important for interpretation of testing results and providing genetic counseling.

  12. The heparin-binding domain of HB-EGF mediates localization to sites of cell-cell contact and prevents HB-EGF proteolytic release

    Energy Technology Data Exchange (ETDEWEB)

    Prince, Robin N.; Schreiter, Eric R.; Zou, Peng; Wiley, H. S.; Ting, Alice Y.; Lee, Richard T.; Lauffenburger, Douglas A.

    2010-07-01

    Heparin-binding EGF-like growth factor (HB-EGF) is a ligand for EGF receptor (EGFR) and possesses the ability to signal in juxtacrine, autocrine and/or paracrine mode, with these alternatives being governed by the degree of proteolytic release of the ligand. Although the spatial range of diffusion of released HB-EGF is restricted by binding heparan-sulfate proteoglycans (HSPGs) in the extracellular matrix and/or cellular glycocalyx, ascertaining mechanisms governing non-released HB-EGF localization is also important for understanding its effects. We have employed a new method for independently tracking the localization of the extracellular EGFlike domain of HB-EGF and the cytoplasmic C-terminus. A striking observation was the absence of the HB-EGF transmembrane proform from the leading edge of COS-7 cells in a wound-closure assay; instead, this protein localized in regions of cell-cell contact. A battery of detailed experiments found that this localization derives from a trans interaction between extracellular HSPGs and the HBEGF heparin-binding domain, and that disruption of this interaction leads to increased release of soluble ligand and a switch in cell phenotype from juxtacrine-induced growth inhibition to autocrine-induced proliferation. Our results indicate that extracellular HSPGs serve to sequester the transmembrane pro-form of HB-EGF at the point of cell-cell contact, and that this plays a role in governing the balance between juxtacrine versus autocrine and paracrine signaling.

  13. HB-LINE ANION EXCHANGE PURIFICATION OF AFS-2 PLUTONIUM FOR MOX

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E.; King, W.

    2012-04-25

    Non-radioactive cerium (Ce) and radioactive plutonium (Pu) anion exchange column experiments using scaled HB-Line designs were performed to investigate the feasibility of using either gadolinium nitrate (Gd) or boric acid (B as H{sub 3}BO{sub 3}) as a neutron poison in the H-Canyon dissolution process. Expected typical concentrations of probable impurities were tested and the removal of these impurities by a decontamination wash was measured. Impurity concentrations are compared to two specifications - designated as Column A or Column B (most restrictive) - proposed for plutonium oxide (PuO{sub 2}) product shipped to the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). Use of Gd as a neutron poison requires a larger volume of wash for the proposed Column A specification. Since boron (B) has a higher proposed specification and is more easily removed by washing, it appears to be the better candidate for use in the H-Canyon dissolution process. Some difficulty was observed in achieving the Column A specification due to the limited effectiveness that the wash step has in removing the residual B after {approx}4 BV's wash. However a combination of the experimental 10 BV's wash results and a calculated DF from the oxalate precipitation process yields an overall DF sufficient to meet the Column A specification. For those impurities (other than B) not removed by 10 BV's of wash, the impurity is either not expected to be present in the feedstock or process, or recommendations have been provided for improvement in the analytical detection/method or validation of calculated results. In summary, boron is recommended as the appropriate neutron poison for H-Canyon dissolution and impurities are expected to meet the Column A specification limits for oxide production in HB-Line.

  14. HB-LINE ANION EXCHANGE PURIFICATION OF AFS-2 PLUTONIUM FOR MOX

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E. A.; King, W. D.

    2012-07-31

    Non-radioactive cerium (Ce) and radioactive plutonium (Pu) anion exchange column experiments using scaled HB-Line designs were performed to investigate the feasibility of using either gadolinium nitrate (Gd) or boric acid (B as H{sub 3}BO{sub 3}) as a neutron poison in the H-Canyon dissolution process. Expected typical concentrations of probable impurities were tested and the removal of these impurities by a decontamination wash was measured. Impurity concentrations are compared to two specifications - designated as Column A or Column B (most restrictive) - proposed for plutonium oxide (PuO{sub 2}) product shipped to the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). Use of Gd as a neutron poison requires a larger volume of wash for the proposed Column A specification. Since boron (B) has a higher proposed specification and is more easily removed by washing, it appears to be the better candidate for use in the H-Canyon dissolution process. Some difficulty was observed in achieving the Column A specification due to the limited effectiveness that the wash step has in removing the residual B after ~4 BV's wash. However a combination of the experimental 10 BV's wash results and a calculated DF from the oxalate precipitation process yields an overall DF sufficient to meet the Column A specification. For those impurities (other than B) not removed by 10 BV's of wash, the impurity is either not expected to be present in the feedstock or process, or recommendations have been provided for improvement in the analytical detection/method or validation of calculated results. In summary, boron is recommended as the appropriate neutron poison for H-Canyon dissolution and impurities are expected to meet the Column A specification limits for oxide production in HB-Line.

  15. Formation of hemoglobin (Hb)-octadecylamine (ODA) Langmuir-Blodgett (LB) film by spreading Hb solution directly onto subphase covered with a layer of ODA and its electrochemical property

    International Nuclear Information System (INIS)

    Yin Fan; Shin, Hoon-Kyu; Kwon, Young-Soo

    2006-01-01

    The formation of hemoglobin (Hb)-octadecylamine (ODA) Langmuir-Blotgett (LB) film by spreading Hb solution directly onto subphase covered with a layer of ODA and its electrochemical properties were studied in this paper. This method ensured better electrode activity because almost no protein was adsorbed onto electrode surface before depositing Hb-ODA monolayer onto electrode surface. The optimum equilibrium time of Hb interacted with ODA layer, the optimum protein amount spread onto subphase's interface and the optimum ionic strength and pH of subphase were obtained from the experimental results. The compressibility analyses of Hb-ODA films showed that the surface pressure of this film from liquid-expanded to liquid-condensed state ranged between 16 and 40 mN/m. Direct electron transfer of Hb immobilized on gold electrode by LB technique was observed by cyclic voltammetry. Results showed that Hb molecules still kept their electrochemical activity. The electrode with Hb-ODA LB film displayed the fastest electron transfer rate when the film transferred under the surface pressure of 35 mN/m

  16. Formation of hemoglobin (Hb)-octadecylamine (ODA) Langmuir-Blodgett (LB) film by spreading Hb solution directly onto subphase covered with a layer of ODA and its electrochemical property

    Energy Technology Data Exchange (ETDEWEB)

    Yin Fan [Department of Electrical Engineering, Dong-A University, Busan 604-714 (Korea, Republic of); Department of Chemistry, Changshu Institute of Technology, Changshu, 215500 (China); Shin, Hoon-Kyu [Department of Electrical Engineering, Dong-A University, Busan 604-714 (Korea, Republic of); Kwon, Young-Soo [Department of Electrical Engineering, Dong-A University, Busan 604-714 (Korea, Republic of)]. E-mail: yskwon@daunet.donga.ac.kr

    2006-03-21

    The formation of hemoglobin (Hb)-octadecylamine (ODA) Langmuir-Blotgett (LB) film by spreading Hb solution directly onto subphase covered with a layer of ODA and its electrochemical properties were studied in this paper. This method ensured better electrode activity because almost no protein was adsorbed onto electrode surface before depositing Hb-ODA monolayer onto electrode surface. The optimum equilibrium time of Hb interacted with ODA layer, the optimum protein amount spread onto subphase's interface and the optimum ionic strength and pH of subphase were obtained from the experimental results. The compressibility analyses of Hb-ODA films showed that the surface pressure of this film from liquid-expanded to liquid-condensed state ranged between 16 and 40 mN/m. Direct electron transfer of Hb immobilized on gold electrode by LB technique was observed by cyclic voltammetry. Results showed that Hb molecules still kept their electrochemical activity. The electrode with Hb-ODA LB film displayed the fastest electron transfer rate when the film transferred under the surface pressure of 35 mN/m.

  17. The magnet measurement facility for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Kim, S.H.; Doose, C.; Hogrefe, R.; Kim, K.; Merl, R.

    1993-01-01

    A magnet measurement facility has been developed to measure the prototype and production magnets for the Advance Photon Source. The measurement facility is semi-automatic in measurement control and data analysis. One dipole system and three rotating coil measurement systems for quadrupole and sextupole magnets and corresponding probe coils are described

  18. [Effects of benazepril and valsartan on erythropoietin levels in patients with essential hypertension].

    Science.gov (United States)

    Guo, Lin-lin; Li, Min; Wang, Ai-hong

    2011-10-01

    To compare effects of valsartan and benazepril on erythropoietin (EPO) levels in essential hypertensive patients with normal renal function. Sixty essential hypertensive patients were randomly divided into valsartan group (n=30, valsartan 80 mg/day) and benazepril group (n=30, benazepril 10 mg/day). Plasma EPO and hemoglobin (Hb) levels were measured at the start of and at 4 and 8 weeks during the treatments. EPO and Hb levels were all in normal range in the two groups. Valsartan decreased EPO levels from 14.179∓3.214 U/L (baseline) to 12.138∓2.926 U/L (PBenazepril treatment did not resulted in any obvious changes in EPO or Hb levels (P>0.05). Valsartan may lower EPO and Hb levels in patients with essential hypertension, while benazepril does not have such effects. The safety of valsartan in anemic hypertensive patients should be further investigated.

  19. The Stricter the Better? The Relationship between Targeted HbA1c Values and Metabolic Control of Pediatric Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Braun, Marcin; Tomasik, Bartlomiej; Wrona, Ewa; Fendler, Wojciech; Jarosz-Chobot, Przemyslawa; Szadkowska, Agnieszka; Zmysłowska, Agnieszka; Wilson, Jayne; Mlynarski, Wojciech

    2016-01-01

    It remains unclear how HbA1c recommendations influence metabolic control of paediatric patients with type 1 diabetes mellitus. To evaluate this we compared reported HbA1c with guideline thresholds. We searched systematically MEDLINE and EMBASE for studies reporting on HbA1c in children with T1DM and grouped them according to targeted HbA1c obtained from regional guidelines. We assessed the discrepancies in the metabolic control between these groups by comparing mean HbA1c extracted from each study and the differences between actual and targeted HbA1c. We included 105 from 1365 searched studies. The median (IQR) HbA1c for the study population was 8.30% (8.00%-8.70%) and was lower in "6.5%" than in "7.5%" as targeted HbA1c level (8.20% (7.85%-8.57%) versus 8.40% (8.20%-8.80%); p = 0.028). Median difference between actual and targeted HbA1c was 1.20% (0.80%-1.70%) and was higher in "6.5%" than in "7.5%" (1.70% (1.30%-2.07%) versus 0.90% (0.70%-1.30%), resp.; p HbA1c levels being closer to the therapeutic goal, but the actual values are still higher than those observed in the "6.5%" group. A meta-analysis of raw data from national registries or a prospective study comparing both approaches is warranted as the next step to examine this subject further.

  20. Glycated Hemoglobin Levels in Patients with Decompensated Cirrhosis

    Directory of Open Access Journals (Sweden)

    Jeffrey Nadelson

    2016-01-01

    Full Text Available Introduction. Aim of this study is to determine if HbA1c levels are a reliable predictor of glycemic control in patients with decompensated cirrhosis. Methods. 200 unique patients referred for liver transplantation at University of Tennessee/Methodist University Transplant Institute with a HbA1c result were included. Three glucose levels prior to the “measured” A1c (MA1c were input into an HbA1c calculator from the American Diabetes Association website to determine the “calculated” A1c (CA1c. The differences between MA1c and CA1c levels were computed. Patients were divided into three groups: group A, difference of 1.5. Results. 97 (49% patients had hemoglobin A1c of less than 5%. Discordance between calculated and measured HbA1c of >0.5% was seen in 47% (n=94. Higher level of discordance of greater than >1.5 was in 12% of patients (n=24. Hemoglobin was an independent predictor for higher discordance (odds ratio 0.77 95%, CI 0.60–0.99, and p value 0.04. HbA1c was an independent predictor of occurrence of HCC (OR 2.69 955, CI 1.38–5.43, and p value 0.008. Conclusion. HbA1c is not a reliable predictor of glycemic control in patients with decompensated cirrhosis, especially in those with severe anemia.

  1. Glycated Hemoglobin Measurement and Prediction of Cardiovascular Disease

    DEFF Research Database (Denmark)

    Di Angelantonio, Emanuele; Gao, Pei; Khan, Hassan

    2014-01-01

    IMPORTANCE: The value of measuring levels of glycated hemoglobin (HbA1c) for the prediction of first cardiovascular events is uncertain. OBJECTIVE: To determine whether adding information on HbA1c values to conventional cardiovascular risk factors is associated with improvement in prediction of c...

  2. HbE/β-Thalassemia and Oxidative Stress: The Key to Pathophysiological Mechanisms and Novel Therapeutics

    Science.gov (United States)

    Sibmooh, Nathawut; Fucharoen, Suthat

    2017-01-01

    Abstract Significance: Oxidative stress and generation of free radicals are fundamental in initiating pathophysiological mechanisms leading to an inflammatory cascade resulting in high rates of morbidity and death from many inherited point mutation-derived hemoglobinopathies. Hemoglobin (Hb)E is the most common point mutation worldwide. The βE-globin gene is found in greatest frequency in Southeast Asia, including Thailand, Malaysia, Indonesia, Vietnam, Cambodia, and Laos. With the wave of worldwide migration, it is entering the gene pool of diverse populations with greater consequences than expected. Critical Issues: While HbE by itself presents as a mild anemia and a single gene for β-thalassemia is not serious, it remains unexplained why HbE/β-thalassemia (HbE/β-thal) is a grave disease with high morbidity and mortality. Patients often exhibit defective physical development, severe chronic anemia, and often die of cardiovascular disease and severe infections. Recent Advances: This article presents an overview of HbE/β-thal disease with an emphasis on new findings pointing to pathophysiological mechanisms derived from and initiated by the dysfunctional property of HbE as a reduced nitrite reductase concomitant with excess α-chains exacerbating unstable HbE, leading to a combination of nitric oxide imbalance, oxidative stress, and proinflammatory events. Future Directions: Additionally, we present new therapeutic strategies that are based on the emerging molecular-level understanding of the pathophysiology of this and other hemoglobinopathies. These strategies are designed to short-circuit the inflammatory cascade leading to devastating chronic morbidity and fatal consequences. Antioxid. Redox Signal. 26, 794–813. PMID:27650096

  3. HbE/β-Thalassemia and Oxidative Stress: The Key to Pathophysiological Mechanisms and Novel Therapeutics.

    Science.gov (United States)

    Hirsch, Rhoda Elison; Sibmooh, Nathawut; Fucharoen, Suthat; Friedman, Joel M

    2017-05-10

    Oxidative stress and generation of free radicals are fundamental in initiating pathophysiological mechanisms leading to an inflammatory cascade resulting in high rates of morbidity and death from many inherited point mutation-derived hemoglobinopathies. Hemoglobin (Hb)E is the most common point mutation worldwide. The β E -globin gene is found in greatest frequency in Southeast Asia, including Thailand, Malaysia, Indonesia, Vietnam, Cambodia, and Laos. With the wave of worldwide migration, it is entering the gene pool of diverse populations with greater consequences than expected. While HbE by itself presents as a mild anemia and a single gene for β-thalassemia is not serious, it remains unexplained why HbE/β-thalassemia (HbE/β-thal) is a grave disease with high morbidity and mortality. Patients often exhibit defective physical development, severe chronic anemia, and often die of cardiovascular disease and severe infections. Recent Advances: This article presents an overview of HbE/β-thal disease with an emphasis on new findings pointing to pathophysiological mechanisms derived from and initiated by the dysfunctional property of HbE as a reduced nitrite reductase concomitant with excess α-chains exacerbating unstable HbE, leading to a combination of nitric oxide imbalance, oxidative stress, and proinflammatory events. Additionally, we present new therapeutic strategies that are based on the emerging molecular-level understanding of the pathophysiology of this and other hemoglobinopathies. These strategies are designed to short-circuit the inflammatory cascade leading to devastating chronic morbidity and fatal consequences. Antioxid. Redox Signal. 26, 794-813.

  4. Recent Progress in Electrochemical HbA1c Sensors: A Review

    Directory of Open Access Journals (Sweden)

    Baozhen Wang

    2015-03-01

    Full Text Available This article reviews recent progress made in the development of electrochemical glycated hemoglobin (HbA1c sensors for the diagnosis and management of diabetes mellitus. Electrochemical HbA1c sensors are divided into two categories based on the detection protocol of the sensors. The first type of sensor directly detects HbA1c by binding HbA1c on the surface of an electrode through bio-affinity of antibody and boronic acids, followed by an appropriate mode of signal transduction. In the second type of sensor, HbA1c is indirectly determined by detecting a digestion product of HbA1c, fructosyl valine (FV. Thus, the former sensors rely on the selective binding of HbA1c to the surface of the electrodes followed by electrochemical signaling in amperometric, voltammetric, impedometric, or potentiometric mode. Redox active markers, such as ferrocene derivatives and ferricyanide/ferrocyanide ions, are often used for electrochemical signaling. For the latter sensors, HbA1c must be digested in advance by proteolytic enzymes to produce the FV fragment. FV is electrochemically detected through catalytic oxidation by fructosyl amine oxidase or by selective binding to imprinted polymers. The performance characteristics of HbA1c sensors are discussed in relation to their use in the diagnosis and control of diabetic mellitus.

  5. Investigation of the effect of hemoglobin F and A levels on development of retinopathy of prematurity.

    Science.gov (United States)

    Erdöl, Hidayet; Hacioglu, Dilek; Kola, Mehmet; Türk, Adem; Aslan, Yakup

    2017-04-01

    To investigate the effect of hemoglobin F (HbF) and hemoglobin A (HbA) levels on development of retinopathy of prematurity (ROP) in premature infants. In this prospective study, blood samples were collected from the side of the heel of 49 premature infants at postnatal months 0, 1, 2, and 3. HbF and HbA levels were measured in all samples and analyzed statistically. Furthermore, correlation analysis was performed regarding development of ROP, blood transfusion, and HbF and HbA levels. A total of 49 infants were included. The mean gestational age of the premature infants was 30.9 ± 2.7 weeks (range, 25-35 weeks); mean birth weight, 1542 ± 582 g (range, 520-3240 g). Of the 49 premature infants, stage 1 ROP or above developed in 26 (53%). Mean HbF levels were lower at postnatal months 1 and 2 in premature infants with ROP compared to those without ROP (P = 0.013 and 0.02, respectively); however, mean HbA levels were higher in the infants with ROP than the others (P = 0.034 and 0.029, respectively). Analysis of covariance that ignored transfusion revealed no difference between the means of Hb variants in the infants with and without ROP (P = 0.572 and 0.486). Blood transfusion significantly altered the levels of HbF and HbA in premature infants, and Hb variants have no direct effect on development of ROP. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  6. Detailed description of an SSAC at the facility level for research laboratory facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-08-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in a research laboratory facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  7. Influencing Pathways to Quality of Life and HbA1c in Patients With Diabetes: A Longitudinal Study That Inform Evidence-Based Practice.

    Science.gov (United States)

    Hsu, Hui-Chun; Lee, Yau-Jiunn; Wang, Ruey-Hsia

    2018-04-01

    Determining possible associated factors and the influencing pathways to hemoglobin A1C (HbA1C) levels and quality of life (QoL) will facilitate the development of effective interventions to improve the physical and psychosocial health of patients with type 2 diabetes mellitus (T2DM). To test a hypothesized model that addressed the pathways among personal characteristics, social support, diabetes distress, and self-care behaviors to HbA1C and QoL. A total of 382 adults with T2DM were recruited. Self-reported questionnaires and medical records were used to collect data regarding personal characteristics, diabetes distress, and social support at baseline. The self-care behaviors characters were collected 6 months later, as well as QoL and HbA1C levels 1 year later. The 12-month QoL directly affected 12-month HbA1C levels. The 6-month self-care behaviors directly affected 12-month QoL, and indirectly affected 12-month HbA1C levels through 12-month QoL. Baseline diabetes distress directly affected 12-month QoL. Moreover, baseline diabetes distress indirectly affected 12-month HbA1C levels through 12-month QoL. Baseline social support directly affected baseline diabetes distress and 6-month self-care behaviors. In addition, baseline social support indirectly affected 12-month QoL through baseline diabetes distress. Baseline social support also indirectly affected 12-month QoL through 6-month self-care behaviors. Enhancing QoL is important to improve HbA1C levels. Enhancing self-care behaviors is essential to improve subsequent HbA1C control and QoL. Reducing diabetes distress is crucial to improve subsequent QoL. Improving social support is suggested a favorable strategy to reduce diabetes distress and enhance subsequent self-care behaviors in patients with T2DM. © 2018 Sigma Theta Tau International.

  8. Progress in neutron beam development at the HFR Petten (feasibility study for a BNCT facility)

    International Nuclear Information System (INIS)

    Constantine, G.; Moss, R.L.; Watkins, P.R.D.; Perks, C.A.; Delafield, H.J.; Ross, D.; Voorbraak, W.P.; Paardekooper, A.; Freudenreich, W.E.; Stecher-Rasmussen, F.

    1990-08-01

    Boron Neutron Capture Therapy, using intermediate energy neutrons to achieve the deep penetration essential for treating brain tumours, can be implemented with a filtered reactor neutron beam. This is designed to minimize the mean energy of the neutrons to keep proton recoil damage to the scalp within normal tissue tolerance limits whilst delivering the required thermal neutron fluence to the tumour over a reasonably short period. This can only be realized in conjunction with a high power density reactor. At the Joint Research Centre Petten an optimized neutron filter is currently being built for installation into the HB11 beam tube of the High Flux Reactor HFR. Part of the development leading to this design has been an extensive study of broad spectrum, filtered beam performance on the HB7 beam tube facility. A wide range of calculations was performed using the Monte Carlo code, MCPN, supported by validation experiments in which several filter configuration incorporating aluminium, sulphur, liquid argon, titanium and cadmium were installed for low power measurements of the neutron fluence rate, neutron spectra and beam gamma-ray contamination. The measurements were carried out within a successful European collaboration. Evaluations were made of the reactor core edge and unfiltered beam spectra, for comparison with MCNP calculations. Multi-foil activation methods and also gamma dose determination in the filtered beam using thermo-luminescent detectors were performed by the ECN. The Harwell/ Birmingham University collaborators undertook the neutron spectrum measurements in the filtered beam. proton recoil spectrometry was used above 30 keV, combined with a multi-sphere and BF 3 chamber response modification technique. Subsequent spectrum adjustment was carried out with the SENSAK code. The agreement between the calculated and measured spectra has given confidence in the reactor and filter modelling methods used to design the HB11 therapy facility. (author). 12 refs

  9. Effectiveness of counseling at primary health facilities: Level of ...

    African Journals Online (AJOL)

    Effectiveness of counseling at primary health facilities: Level of knowledge of antenatal attendee and their ... Objectives: To determine the effectiveness of counseling on HIV done in primary health facilities ... AJOL African Journals Online.

  10. Mutual inductance appliance for measuring the level of a molten metal

    International Nuclear Information System (INIS)

    Zbinden, Marc.

    1982-01-01

    The invention concerns an appliance for measuring the level of a molten metal of the kind using the variation of the mutual inductance between two imbricated windings depending on the level of the free area of the molten metal in the range of levels taken up by the windings. It has a particularly significant use in measuring the level of liquid sodium, especially in nuclear facilities where sodium is used as coolant [fr

  11. Transcriptional regulation of Hb-α and Hb-β through nuclear factor E2-related factor-2 (Nrf2) activation in human vaginal cells: A novel mechanism of cellular adaptability to oxidative stress.

    Science.gov (United States)

    Saha, Debarchana; Koli, Swanand; Reddy, Kudumula Venkata Rami

    2017-06-01

    Hemoglobin (Hb), a major protein involved in transport of oxygen (O 2 ), is expressed by erythroid lineages. Until recently, it was not known whether non-erythroid cells express Hb. The objective was to evaluate the expression and functional significance of Hb-α and Hb-β in human primary vaginal epithelial cells (hPVECs) and decipher downstream signaling. RT-PCR, qRT-PCR, flow cytometry, Western blot, immunofluorescence were used to evaluate the expression of Hb-α, Hb-β, and nuclear factor E2-related factor-2(Nrf2) after hydrogen peroxide (H 2 O 2 ) induction. Electrophoretic mobility shift assay (EMSA) and chromatin immunoprecipitation (ChIP) assay were used to determine the binding efficiency of Nrf2 on the Hb-α promoter. Stimulation of hPVECs and human vaginal epithelial cell line, VK2/E6E7 with H 2 O 2 augmented the expression of Hb-α, Hb-β, Nrf2, heme oxygenase-1 (HO-1), and reactive oxygen species (ROS). Treatment of these cells with Nrf2 inhibitor, trigonelline (Trig) inhibited Hb-α and Hb-β expressions. Hb-α and Hb-β overexpression downregulated H 2 O 2 -induced ROS. The presence of Nrf2 binding domain was demonstrated within Hb-α promoter. The results revealed for the first time that Hb-α and Hb-β were induced by oxidative stress through the activation of Nrf2. Overexpression of Hb-α and Hb-β ameliorated H 2 O 2 -induced oxidative stress, indicating one of the possible mechanism(s) to protect hPVECS from oxidative stress. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Automatic Measurement of Low Level Contamination on Concrete Surfaces

    International Nuclear Information System (INIS)

    Tachibana, M.; Itoh, H.; Shimada, T.; Yanagihara, S.

    2002-01-01

    Automatic measurement of radioactivity is necessary for considering cost effectiveness in final radiological survey of building structures in decommissioning nuclear facilities. The RAPID (radiation measuring pilot device for surface contamination) was developed to be applied to automatic measurement of low level contamination on concrete surfaces. The RAPID has a capability to measure contamination with detection limit of 0.14 Bq/cm2 for 60Co in 30 seconds of measurement time and its efficiency is evaluated to be 5 m2/h in a normal measurement option. It was confirmed that low level contamination on concrete surfaces could be surveyed by the RAPID efficiently compared with direct measurement by workers through its actual application

  13. Measurement of Outflow Facility Using iPerfusion.

    Directory of Open Access Journals (Sweden)

    Joseph M Sherwood

    Full Text Available Elevated intraocular pressure (IOP is the predominant risk factor for glaucoma, and reducing IOP is the only successful strategy to prevent further glaucomatous vision loss. IOP is determined by the balance between the rates of aqueous humour secretion and outflow, and a pathological reduction in the hydraulic conductance of outflow, known as outflow facility, is responsible for IOP elevation in glaucoma. Mouse models are often used to investigate the mechanisms controlling outflow facility, but the diminutive size of the mouse eye makes measurement of outflow technically challenging. In this study, we present a new approach to measure and analyse outflow facility using iPerfusion™, which incorporates an actuated pressure reservoir, thermal flow sensor, differential pressure measurement and an automated computerised interface. In enucleated eyes from C57BL/6J mice, the flow-pressure relationship is highly non-linear and is well represented by an empirical power law model that describes the pressure dependence of outflow facility. At zero pressure, the measured flow is indistinguishable from zero, confirming the absence of any significant pressure independent flow in enucleated eyes. Comparison with the commonly used 2-parameter linear outflow model reveals that inappropriate application of a linear fit to a non-linear flow-pressure relationship introduces considerable errors in the estimation of outflow facility and leads to the false impression of pressure-independent outflow. Data from a population of enucleated eyes from C57BL/6J mice show that outflow facility is best described by a lognormal distribution, with 6-fold variability between individuals, but with relatively tight correlation of facility between fellow eyes. iPerfusion represents a platform technology to accurately and robustly characterise the flow-pressure relationship in enucleated mouse eyes for the purpose of glaucoma research and with minor modifications, may be applied

  14. The Effect of Group Counseling on Physiological Aspect of Self-care and HbA1C Level of Patients with Diabetes Type II

    Directory of Open Access Journals (Sweden)

    Seyedreza Mazlom

    2015-06-01

    Full Text Available Background: The most important underlying cause of death in diabetic patients is poor self-care. The effect of education on self-care promotion has been widely investigated; however, the advisory role and impact of the treatment team have been scarcely investigated.  Aim: Determining the effect of group counseling on the psychological aspect of self-care and level of glycosylated hemoglobin in the patients with diabetes type II. Methods: In a randomized clinical trial, 73 patients with type II diabetes mellitus, who had been referred to Parsian Diabetes clinic of Mashhad in 2014, were divided into two groups of intervention and control. The group counseling program was performed in five 1.5-hour sessions with 3-day intervals, and each groups consisted of 8 to 10 people. The content of the meetings was problems in nutrition, exercise, diabetes mellitus disease, diabetes-related mental health problems, diabetes medications, and self-control of blood glucose. Researcher-made diabetes care questionnaire was filled and HbA1c test was measured before and two months after the intervention. Data were analyzed by SPSS version 11.5 using paired sample and independent t-tests. Results: In this study,27.3 percent of the subjects were male and 72.7 were female with the mean age of 49.1 ± 8.3. The scores of physiological aspect of self-care and HbA1C of the diabetic patients before the intervention was not significantly different between the groups; but in the post-intervention phase, the self-care in intervention group (49.1±5.8 significantly increased compared to the control group (31.8±12.2 (p

  15. Ferulic acid modification enhances the anti-oxidation activity of natural Hb in vitro.

    Science.gov (United States)

    Qi, Donglai; Li, Qian; Chen, Chen; Wang, Xiang

    2018-03-13

    During the development of artificial red blood cell (RBC) substitutes, oxidation side reaction is one of the major factors that hinder the application of haemoglobin (Hb)-based oxygen carriers (HBOCs). In order to avoid oxidation toxicity, we designed and prepared natural Hb conjugated with ferulic acid (FA) via simple chemical modification. In addition, the thiol groups on Hb surface were increased via the reaction of Hb with 2-iminothiolane (2-IT) and then modified with FA for the study of anti-oxidant ability. It was showed that Hb modified with FA (FA-Hb) had similar oxygen-binding capacity to natural Hb. Moreover, the anti-oxidant ability of FA-Hb in vitro in different systems was superior to natural Hb and in proportion to the degree of modification of FA. The results indicate that FA-Hb might have the potential to serve as a novel oxygen carrier with the capacity to reduce oxidative side reaction.

  16. A Coincidental Discovery of a New Stable Variant (Hb Hachioji or HBB: c.187C>T) in a Patient with Chronic Hemolytic Anemia of Unexplained Origin.

    Science.gov (United States)

    Mella, Ferania; Yamashiro, Yasuhiro; Adhiyanto, Chris; Tanaka, Tatehiko; Nitta, Takenori; Amao, Yuki; Kimoto, Masafumi

    2018-01-01

    We report a new hemoglobin (Hb) variant, Hb Hachioji (HBB: c.187C>T), which was detected in a 32-year-old male with hemolytic anemia. The proband had undergone splenectomy in his childhood after being diagnosed with hereditary spherocytosis (HS) with no clinical improvement. A recent study showed that Heinz bodies were frequently observed in his red cells, however, no abnormal band was separated by isoelectric focusing (IEF), and the isopropanol (instability) test was negative. Direct sequencing revealed that the proband was a heterozygous carrier of a novel mutation (GCT>GTT) at codon 62 of the β-globin gene, leading to an alanine to valine substitution. This variant was named Hb Hachioji. Characterization at the mRNA level by cDNA sequencing detected β Hachioji mRNA, as well as β A mRNA. Subsequently, study of the proband's family indicated that his father was a carrier of this Hb variant, although unexpectedly, the father was asymptomatic and clinically healthy. Oxygen affinity measurement of total Hb showed no alteration in the P 50 and oxygen equilibrium curve. The presence of Hb Hachioji was confirmed by mass spectrometry (MS). Hb Hachioji comprised approximately 50.0% of the total Hb and was a stable variant. The phenotypic discrepancy between these two carriers suggests that Hb Hachioji may not be associated with the hemolytic involvement in the proband. P4.2Nippon, which is the primary cause of most cases of Japanese HS, was absent in the proband's parents. The coexistence of glucose-6-phosphate dehydrogenase (G6PD) deficiency was ruled out. Thus, the cause of hemolytic involvement in this patient remains unclear.

  17. Hb A1c Determination by Capillary Electrophoresis is an Efficient Method for Detecting β-Thalassemias and Hemoglobin Variants.

    Science.gov (United States)

    Orts, Juan A; Zúñiga, Ángel; Bello, Yanis; Fabregat, Aleix B; Vicente, Ana I

    2016-09-01

    Glycated hemoglobin (Hb A 1c ) determination by multicapillary zone electrophoresis (MZE) can additionally be used to detect Hb A 2 , Hb F and most common hemoglobin (Hb) variants. We assessed the effectiveness of this method for detecting β-thalassemia (β-thal), δβ-thalassemia (δβ-thal) and most common Hb variants. Moreover, Hb F/Hb A 2 is evaluated as an index for discriminating between β- and δβ-thal traits. The theoretical β-thalassemia major (β-TM) birth rate in our healthcare area is calculated and contrasted with real data. A MZE technique was used for Hb A 1c measurements in 27,724 patients. Previous criteria for carrier detection were established and subsequently confirmed by molecular biology techniques. Positive predictive value (PPV) was 100.0%. The prevalence of β-thal trait (including δβ-thal) was 0.34%. The most prevalent mutations (estimated per 100,000 population) were HBB: c.118C > T (57.7%), HBB: c.93-21G>A (50.5%), HBB: c.92 + 1G > A (43.3%), HBB: c.92 + 6T > C (32.5%) and HBB: c.20delA (18.0%) for β-thalassemias, and Hb S (HBB: c.20A > T) (32.5%) and Hb J-Baltimore (HBB:c.3880T>A) (28.9%) for Hb variants. We found a paradoxical result between the theoretical β-TM birth rate and real data. We calculated an optimal Hb F/Hb A 2 index cutoff of 0.71 for discriminating between β- and δβ-thal traits. This method is highly cost-effective for detecting β-thalassemias and common Hb variants. Prevalence results match previous data for the Spanish population. Heterogeneity of mutations in Spain has markedly increased as a consequence of migration. The Hb F/Hb A 2 index cutoff could be used to predict δβ-thal trait.

  18. Direct shaft torque measurements in a transient turbine facility

    International Nuclear Information System (INIS)

    Beard, Paul F; Povey, Thomas

    2011-01-01

    This paper describes the development and implementation of a shaft torque measurement system for the Oxford Turbine Research Facility (formerly the Turbine Test Facility (TTF) at QinetiQ, Farnborough), or OTRF. As part of the recent EU TATEF II programme, the facility was upgraded to allow turbine efficiency measurements to be performed. A shaft torque measurement system was developed as part of this upgrade. The system is unique in that, to the authors' knowledge, it provided the first direct measurement of shaft torque in a transient turbine facility although the system has wider applicability to rotating test facilities in which power measurement is a requirement. The adopted approach removes the requirement to quantify bearing friction, which can be difficult to accurately calibrate under representative operating conditions. The OTRF is a short duration (approximately 0.4 s run time) isentropic light-piston facility capable of matching all of the non-dimensional parameters important for aerodynamic and heat studies, namely Mach number, Reynolds number, non-dimensional speed, stage pressure ratio and gas-to-wall temperature ratio. The single-stage MT1 turbine used for this study is a highly loaded unshrouded design, and as such is relevant to modern military, or future civil aero-engine design. Shaft torque was measured directly using a custom-built strain gauge-based torque measurement system in the rotating frame of reference. This paper describes the development of this measurement system. The system was calibrated, including the effects of temperature, to a traceable primary standard using a purpose-built facility. The bias and precision uncertainties of the measured torque were ±0.117% and ±0.183%, respectively. To accurately determine the shaft torque developed by a turbine in the OTRF, small corrections due to inertial torque (associated with changes in the rotational speed) and aerodynamic drag (windage) are required. The methods for performing these

  19. Stat5 phosphorylation is responsible for the excessive potency of HB-EGF.

    Science.gov (United States)

    Heo, Jeongyeon; Kim, Jae Geun; Kim, Sunghwan; Kang, Hara

    2017-12-23

    Heparin-binding EGF-like growth factor (HB-EGF) is a potent growth factor involved in wound healing and tumorigenesis. Despite the sequence similarity between HB-EGF and EGF, HB-EGF induces cellular proliferation and migration more potently than EGF. However, the differential regulation by HB-EGF and EGF has not been thoroughly elucidated. In this study, we compared signaling pathways activated by HB-EGF and EGF to understand the details of the molecular mechanism of the high potency induced by HB-EGF. HB-EGF specifically induced the phosphorylation of EGFR-Y1045 and activated Stat5, which is responsible for promoting cell proliferation, and migration. The competition of phosphorylated EGFR-Y1045 inhibited Stat5 activation and consequently lowered the effect of HB-EGF on cell proliferation, suggesting that the phosphorylation of EGFR-Y1045 is essential for the activation of Stat5. The phosphorylation of EGFR-Y1045 and Stat5 induced by HB-EGF was prevented by sequestering the heparin-binding domain, suggesting that the heparin-binding domain is critical for HB-EGF-mediated signaling and cellular responses. In conclusion, the heparin-binding domain of HB-EGF was responsible for EGFR-mediated Stat5 activation, resulting in a more potent cellular proliferation, and migration than that mediated by EGF. This molecular mechanism is useful for understanding ligand-specific EGFR signaling and developing biomedicines for wound healing or cancer therapy. © 2017 Wiley Periodicals, Inc.

  20. Prevalence and phenotype of diabetes and prediabetes using fasting glucose vs HbA1c in a Caribbean population.

    Science.gov (United States)

    Unwin, Nigel; Howitt, Christina; Rose, Angela Mc; Samuels, T Alafia; Hennis, Anselm Jm; Hambleton, Ian R

    2017-12-01

    Both fasting plasma glucose (FPG) and HbA1c are recommended for the diagnosis of diabetes and prediabetes by the American Diabetes Association (ADA), and for diabetes by the World Health Organization. The ADA guidance is influential on clinical practice in many developing countries, including in the Caribbean and Latin America. We aimed to compare the prevalence and characteristics of individuals identified as having diabetes and prediabetes by FPG and HbA1c in a predominantly African ancestry Caribbean population. A representative population-based sample of 1234 adults (≥25 years of age) resident in Barbados was recruited. Standard methods with appropriate quality control were used to collect data on height, weight, blood pressure, fasting lipids and history of diagnosed diabetes, and to measure fasting glucose and HbA1c. Those with previously diagnosed diabetes (n = 192) were excluded from the analyses. Diabetes was defined as: FPG ≥7.0 mmol/L or HbA1c ≥6.5%; prediabetes as: FPG ≥5.6 to prediabetes was higher by HbA1c compared to FPG: 41.7% (37.9, 45.6) vs 15.0% (12.8, 17.5). Overall 558 individuals had prediabetes by either measure, but only 107 on both. HbA1c, but not FPG, was significantly higher in women than men; and FPG, but not HbA1c, was significantly associated with raised triglycerides and low HDL cholesterol. The agreement between FPG and HbA1c defined hyperglycaemia is poor. In addition, there are some differences in the phenotype of those identified, and HbA1c gives a much higher prevalence of prediabetes. The routine use of HbA1c for screening and diagnosis in this population would have major implications for clinical and public health policies and resources. Given the lack of robust evidence, particularly for prediabetes, on whether intervention in the individuals identified would improve outcomes, this approach to screening and diagnosis cannot be currently recommended for this population.

  1. Mapping the Characteristics of Critical Care Facilities: Assessment, Distribution, and Level of Critical Care Facilities from Central India.

    Science.gov (United States)

    Saigal, Saurabh; Sharma, Jai Prakash; Pakhare, Abhijit; Bhaskar, Santosh; Dhanuka, Sanjay; Kumar, Sanjay; Sabde, Yogesh; Bhattacharya, Pradip; Joshi, Rajnish

    2017-10-01

    In low- and middle-income countries such as India, where health systems are weak, the number of available Critical Care Unit (Intensive Care Unit [ICU]) beds is expected to be low. There is no study from the Indian subcontinent that has reported the characteristics and distribution of existing ICUs. We performed this study to understand the characteristics and distribution of ICUs in Madhya Pradesh (MP) state of Central India. We also aimed to develop a consensus scoring system and internally validate it to define levels of care and to improve health system planning and to strengthen referral networks in the state. We obtained a list of potential ICU facilities from various sources and then performed a cross-sectional survey by visiting each facility and determining characteristics for each facility. We collected variables with respect to infrastructure, human resources, equipment, support services, procedures performed, training courses conducted, and in-place policies or standard operating procedure documents. We identified a total of 123 ICUs in MP. Of 123 ICUs, 35 were level 1 facilities, 74 were level 2 facilities, and only 14 were level 3 facilities. Overall, there were 0.17 facilities per 100,000 population (95* confidence interval [CI] 0.14-0.20 per 100,000 populations). There were a total of 1816 ICU beds in the state, with an average of 2.5 beds per 100,000 population (95* CI 2.4-2.6 per 100,000 population). Of the total number of ICU beds, 250 are in level 1, 1141 are in level 2, and 425 are in level 3 facilities. This amounts to 0.34, 1.57, and 0.59 ICU beds per 100,000 population for levels 1, 2, and 3, respectively. This study could just be an eye opener for our healthcare authorities at both state and national levels to estimate the proportion of ICU beds per lac population. Similar mapping of intensive care services from other States will generate national data that is hitherto unknown.

  2. HbA1c Alone Is a Poor Indicator of Cardiometabolic Risk in Middle-Aged Subjects with Pre-Diabetes but Is Suitable for Type 2 Diabetes Diagnosis: A Cross-Sectional Study

    Science.gov (United States)

    Millar, Seán R.; Perry, Ivan J.; Phillips, Catherine M.

    2015-01-01

    Objectives Glycated haemoglobin A1c (HbA1c) measurement is recommended as an alternative to fasting plasma glucose (FPG) for the diagnosis of pre-diabetes and type 2 diabetes. However, evidence suggests discordance between HbA1c and FPG. In this study we examine a range of metabolic risk features, pro-inflammatory cytokines, acute-phase response proteins, coagulation factors and white blood cell counts to determine which assay more accurately identifies individuals at increased cardiometabolic risk. Materials and Methods This was a cross-sectional study involving a random sample of 2,047 men and women aged 46-73 years. Binary and multinomial logistic regression were employed to examine risk feature associations with pre-diabetes [either HbA1c levels 5.7-6.4% (39-46 mmol/mol) or impaired FPG levels 5.6-6.9 mmol/l] and type 2 diabetes [either HbA1c levels >6.5% (>48 mmol/mol) or FPG levels >7.0 mmol/l]. Receiver operating characteristic curve analysis was used to evaluate the ability of HbA1c to discriminate pre-diabetes and diabetes defined by FPG. Results Stronger associations with diabetes-related phenotypes were observed in pre-diabetic subjects diagnosed by FPG compared to those detected by HbA1c. Individuals with type 2 diabetes exhibited cardiometabolic profiles that were broadly similar according to diagnosis by either assay. Pre-diabetic participants classified by both assays displayed a more pro-inflammatory, pro-atherogenic, hypertensive and insulin resistant profile. Odds ratios of having three or more metabolic syndrome features were also noticeably increased (OR: 4.0, 95% CI: 2.8-5.8) when compared to subjects diagnosed by either HbA1c (OR: 1.4, 95% CI: 1.2-1.8) or FPG (OR: 3.0, 95% CI: 1.7-5.1) separately. Conclusions In middle-aged Caucasian-Europeans, HbA1c alone is a poor indicator of cardiometabolic risk but is suitable for diagnosing diabetes. Combined use of HbA1c and FPG may be of additional benefit for detecting individuals at highest odds of

  3. Comparison of facility-level methane emission rates from natural gas production well pads in the Marcellus, Denver-Julesburg, and Uintah Basins

    Science.gov (United States)

    Omara, M.; Li, X.; Sullivan, M.; Subramanian, R.; Robinson, A. L.; Presto, A. A.

    2015-12-01

    The boom in shale natural gas (NG) production, brought about by advances in horizontal drilling and hydraulic fracturing, has yielded both economic benefits and concerns about environmental and climate impacts. In particular, leakages of methane from the NG supply chain could substantially increase the carbon footprint of NG, diminishing its potential role as a transition fuel between carbon intensive fossil fuels and renewable energy systems. Recent research has demonstrated significant variability in measured methane emission rates from NG production facilities within a given shale gas basin. This variability often reflect facility-specific differences in NG production capacity, facility age, utilization of emissions capture and control, and/or the level of facility inspection and maintenance. Across NG production basins, these differences in facility-level methane emission rates are likely amplified, especially if significant variability in NG composition and state emissions regulations are present. In this study, we measured methane emission rates from the NG production sector in the Marcellus Shale Basin (Pennsylvania and West Virginia), currently the largest NG production basin in the U.S., and contrast these results with those of the Denver-Julesburg (Colorado) and Uintah (Utah) shale basins. Facility-level methane emission rates were measured at 106 NG production facilities using the dual tracer flux (nitrous oxide and acetylene), Gaussian dispersion simulations, and the OTM 33A techniques. The distribution of facility-level average methane emission rate for each NG basin will be discussed, with emphasis on how variability in NG composition (i.e., ethane-to-methane ratios) and state emissions regulations impact measured methane leak rates. While the focus of this presentation will be on the comparison of methane leak rates among NG basins, the use of three complimentary top-down methane measurement techniques provides a unique opportunity to explore the

  4. Hb TAYBE: clinical and morphological findings IN 43 patients.

    Science.gov (United States)

    Koren, Ariel; Levin, Carina; Zalman, Luci; Palmor, Haya; Filon, Dvora; Chubar, Evgeny; Resnitzky, Peretz; Bennett, Michael

    2016-08-01

    Hereditary sequence variants in globin genes are usually silent and are rarer in α-globin chains than β-globin chains. Some may lead to an unstable protein with a hemolytic or thalassemic phenotype. Hb Taybe is an unstable α-chain hemoglobin variant caused by the deletion of a threonine residue at codon 38 or 39 of the α1 globin gene. This deletion results in a structural abnormality that affects the α1 β2 contact and the α1 β1 interface, producing a highly unstable Hb. We describe the clinical, laboratory, and morphological characteristics of 43 patients with Hb Taybe, sixteen of whom are heterozygous, eight are homozygous, and nineteen are double heterozygous for Hb Taybe and other α-gene mutations or deletions. The clinical presentation is very variable from a mild hemolytic anemia to the need for red cell transfusion. Morphological characteristics include erythroid hyperplasia, defective hemoglobin production, and dyserythropoietic features. On electron microscopy dyserythropoiesis and cytoplasmic precipitation of globin compatible optical dense material is seen. This is the largest report of Hb Taybe patients. Previous reported cohorts are not related to these cases. We conclude that patients carrying Hb Taybe have a unique hematological and clinical phenotype distinct from other hemoglobinopathies and from congenital dyserythropoietic anemia. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Radioactivity measuring and control method and the system for facility of nuclear power plant

    International Nuclear Information System (INIS)

    Urata, Megumu.

    1996-01-01

    In measurement and control for radioactivity in an inspection operation in radiation circumstance for nuclear power plant facilities, radioactive materials in air are sometimes suspended together with ordinary dusts. Then, when a radiation level is low, light is applied to the suspended dusts to measure the quantity and the number of the dusts thereby estimating the radiation level based on the amount of the dusts. Then, the level of the equipments is informed to an operator based on the estimated value, and an operation time is determined. Since the optical dust monitor is inexpensive, a number of dust monitors can be brought into an operation chamber. In addition, they are reduced in the size and the weight, an operator can carry and bring them into the operation chamber. A distribution of dusts can be determined by measuring the concentration of dusts using a plurality of dust monitors thereby enabling to improve safety and economical property of periodical inspection for nuclear power plant facilities. (T.M.)

  6. Radioactivity measuring and control method and the system for facility of nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu

    1996-12-03

    In measurement and control for radioactivity in an inspection operation in radiation circumstance for nuclear power plant facilities, radioactive materials in air are sometimes suspended together with ordinary dusts. Then, when a radiation level is low, light is applied to the suspended dusts to measure the quantity and the number of the dusts thereby estimating the radiation level based on the amount of the dusts. Then, the level of the equipments is informed to an operator based on the estimated value, and an operation time is determined. Since the optical dust monitor is inexpensive, a number of dust monitors can be brought into an operation chamber. In addition, they are reduced in the size and the weight, an operator can carry and bring them into the operation chamber. A distribution of dusts can be determined by measuring the concentration of dusts using a plurality of dust monitors thereby enabling to improve safety and economical property of periodical inspection for nuclear power plant facilities. (T.M.)

  7. Facility-level association of preoperative stress testing and postoperative adverse cardiac events.

    Science.gov (United States)

    Valle, Javier A; Graham, Laura; Thiruvoipati, Thejasvi; Grunwald, Gary; Armstrong, Ehrin J; Maddox, Thomas M; Hawn, Mary T; Bradley, Steven M

    2018-06-22

    Despite limited indications, preoperative stress testing is often used prior to non-cardiac surgery. Patient-level analyses of stress testing and outcomes are limited by case mix and selection bias. Therefore, we sought to describe facility-level rates of preoperative stress testing for non-cardiac surgery, and to determine the association between facility-level preoperative stress testing and postoperative major adverse cardiac events (MACE). We identified patients undergoing non-cardiac surgery within 2 years of percutaneous coronary intervention in the Veterans Affairs (VA) Health Care System, from 2004 to 2011, facility-level rates of preoperative stress testing and postoperative MACE (death, myocardial infarction (MI) or revascularisation within 30 days). We determined risk-standardised facility-level rates of stress testing and postoperative MACE, and the relationship between facility-level preoperative stress testing and postoperative MACE. Among 29 937 patients undergoing non-cardiac surgery at 131 VA facilities, the median facility rate of preoperative stress testing was 13.2% (IQR 9.7%-15.9%; range 6.0%-21.5%), and 30-day postoperative MACE was 4.0% (IQR 2.4%-5.4%). After risk standardisation, the median facility-level rate of stress testing was 12.7% (IQR 8.4%-17.4%) and postoperative MACE was 3.8% (IQR 2.3%-5.6%). There was no correlation between risk-standardised stress testing and composite MACE at the facility level (r=0.022, p=0.81), or with individual outcomes of death, MI or revascularisation. In a national cohort of veterans undergoing non-cardiac surgery, we observed substantial variation in facility-level rates of preoperative stress testing. Facilities with higher rates of preoperative stress testing were not associated with better postoperative outcomes. These findings suggest an opportunity to reduce variation in preoperative stress testing without sacrificing patient outcomes. © Article author(s) (or their employer(s) unless otherwise

  8. Preliminary Safety Design Report for Remote Handled Low-Level Waste Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Solack; Carol Mason

    2012-03-01

    A new onsite, remote-handled low-level waste disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled low-level waste disposal for remote-handled low-level waste from the Idaho National Laboratory and for nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled low-level waste in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This preliminary safety design report supports the design of a proposed onsite remote-handled low-level waste disposal facility by providing an initial nuclear facility hazard categorization, by discussing site characteristics that impact accident analysis, by providing the facility and process information necessary to support the hazard analysis, by identifying and evaluating potential hazards for processes associated with onsite handling and disposal of remote-handled low-level waste, and by discussing the need for safety features that will become part of the facility design.

  9. Changes in levels of haemoglobin A1c during the first 6 years after diagnosis of clinical type 2 diabetes

    DEFF Research Database (Denmark)

    Olivarius, Niels de Fine; Siersma, V.; Hansen, Lars Jørgen

    2009-01-01

    in HbA(1c) was investigated in a multivariate mixed model. RESULTS: During the first year after diabetes diagnosis, HbA(1c) dropped to near normal average level and then started rising almost linearly. A sharp rise in long-term glycaemic level was observed in approximately a quarter of the patients......OBJECTIVE: To assess the variability in levels of glycosylated haemoglobin (HbA(1c)) during the first six years after diagnosis of clinical type 2 diabetes in relation to possible predictors. MATERIAL AND METHODS: Data were from a population-based sample from general practice of 581 newly diagnosed...... diabetic patients aged 40 or over. Estimation of HbA(1c) was centralized. The changes in levels of HbA(1c) were described by HbA(1c) at diagnosis and a regression line fitted to the HbA(1c) measurements after 1-year follow-up for each patient. The predictive effect of patient characteristics for changes...

  10. Thrombosis in Hb Taybe [codons 38/39 (-ACC) (α1)

    DEFF Research Database (Denmark)

    Juul, Maja Bech; Vestergaard, Hanne; Petersen, Jesper

    2012-01-01

    Hb Taybe is a highly unstable hemoglobin (Hb) variant caused by a 3 bp deletion at codons 38/39 (-ACC) on the α1-globin gene. We report for the first time, a patient with a compound heterozygosity for Hb Taybe and a 5 bp deletion at the splice donor site of IVS-I on the α2-globin gene and ischemic...

  11. Relationship between pulmonary function and elevated glycated hemoglobin levels in health checkups: A cross-sectional observational study in Japanese participants

    Directory of Open Access Journals (Sweden)

    Saigo Baba

    2017-11-01

    Full Text Available Background: Insulin resistance has been associated with cytokines, including interleukin-6 and tumor necrosis factor alpha soluble receptor, both of which are elevated in chronic obstructive pulmonary disease (COPD. Few studies have investigated the relationship between pulmonary function tests using spirometry (PFT and fasting plasma glucose (FPG or glycated hemoglobin (HbA1c levels in Japanese participants. The purpose of this study was to clarify the relationship between PFT in Japanese people who had health checkups and their FPG or HbA1c levels. In the context of preventative medicine, we intend to connect early detection of COPD to an index of blood sugar. Methods: From August 2013 through March 2014, 1019 participants underwent health checkups. PFT, FPG, and HbA1c measurements were conducted. HbA1c levels were measured according to National Glycohemoglobin Standardization Program guidelines. Results: Participants with FPG ≥100 mg/dL and HbA1c ≥5.6% showed a significantly lower forced expiratory volume in 1 s:forced vital capacity ratio (FEV1/FVC compared to participants with lower FPG and Hb1Ac levels. Prevalence of FEV1/FVC values <70% in PFT differed significantly depending on sex, age, body mass index, FPG, HbA1c, and smoking habits. Age (≥60 years, HbA1c (≥5.6%, and current or former smoking were associated with FEV1/FVC values <70%. Conclusion: In Japan, HbA1c levels were higher in participants with FEV1/FVC values <70% in PFT than in those with FEV1/FVC ≥70%. In preventive medicine, PFT by spirometry should be performed in elderly participants with elevated HbA1c levels who are current or former smokers.

  12. A pilot study of an HbA1c chairside screening protocol for diabetes in patients with chronic periodontitis: the dental hygienist's role.

    Science.gov (United States)

    Bossart, M; Calley, K H; Gurenlian, J R; Mason, B; Ferguson, R E; Peterson, T

    2016-05-01

    To assess effectiveness, convenience and cost of point-of-care diabetes screenings performed by a dental hygienist for patients with periodontitis, using a diabetes risk questionnaire, periodontal findings and a glycosylated haemoglobin (HbA1c) analyser. A purposive sample of 50 participants with periodontitis, never diagnosed with diabetes, reporting ≥one diabetes risk factor, were administered an HbA1c test. Spearman's correlation measured relationships between HbA1c and diabetes risk test scores, numbers of missing teeth, percentage of deep pockets ≥5 mm and percentage of bleeding sites (BOP). Cost and time were assessed. Analyses used 0.05 alpha levels. Thirty-two per cent (n = 16) of participants presented HbA1c values indicating prediabetes; one HbA1c value indicated type 2 diabetes, totalling 34% (N = 17). No relationships existed between HbA1c values and diabetes risk scores (rs = 0.153; P = 0.144), numbers of missing teeth (r = 0.190; P = 0.093), percentage of deep pockets (rs = -0.048; P = 0.370) or percentage of BOP sites (rs = 0.066, P = 0.324). Direct cost for each HbA1c was $9US, excluding follow-up medical diagnosis. Mean screening time including patient education was 14 min (SD = 6.2). Fifty-three per cent (n = 9 of 17) of participants with elevated HbA1c values contacted their primary healthcare provider within 2 weeks as recommended. Point-of-care HbA1c screenings by dental hygienists were effective and convenient for identifying undiagnosed prediabetes and provide opportunity for interprofessional patient care; cost or lack of dental insurance may inhibit implementation. Identification of patients at risk for diabetes requires further evaluation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Mixed and Low-Level Waste Treatment Facility project

    International Nuclear Information System (INIS)

    1992-04-01

    Mixed and low-level wastes generated at the Idaho National Engineering Laboratory (INEL) are required to be managed according to applicable State and Federal regulations, and Department of Energy Orders that provide for the protection of human health and the environment. The Mixed and Low-Level Waste Treatment Facility Project was chartered in 1991, by the Department of Energy to provide treatment capability for these mixed and low-level waste streams. The first project task consisted of conducting engineering studies to identify the waste streams, their potential treatment strategies, and the requirements that would be imposed on the waste streams and the facilities used to process them. This report, Appendix A, Environmental ampersand Regulatory Planning ampersand Documentation, identifies the regulatory requirements that would be imposed on the operation or construction of a facility designed to process the INEL's waste streams. These requirements are contained in five reports that discuss the following topics: (1) an environmental compliance plan and schedule, (2) National Environmental Policy Act requirements, (3) preliminary siting requirements, (4) regulatory justification for the project, and (5) health and safety criteria

  14. The incidence of severe hypoglycaemia in pregnant women with type 1 diabetes mellitus can be reduced with unchanged HbA1c levels and pregnancy outcomes in a routine care setting

    DEFF Research Database (Denmark)

    Ringholm, Lene; Secher, A L; Pedersen-Bjergaard, U

    2013-01-01

    To investigate whether the incidence of severe hypoglycaemia in pregnant women with type 1 diabetes can be reduced without deteriorating HbA1c levels or pregnancy outcomes in a routine care setting....

  15. Comparison of the Current Diagnostic Criterion of HbA1c with Fasting and 2-Hour Plasma Glucose Concentration

    Science.gov (United States)

    Karnchanasorn, Rudruidee; Huang, Jean; Feng, Wei; Chuang, Lee-Ming

    2016-01-01

    To determine the effectiveness of hemoglobin A1c (HbA1c) ≥ 6.5% in diagnosing diabetes compared to fasting plasma glucose (FPG) ≥ 126 mg/dL and 2-hour plasma glucose (2hPG) ≥ 200 mg/dL in a previously undiagnosed diabetic cohort, we included 5,764 adult subjects without established diabetes for whom HbA1c, FPG, 2hPG, and BMI measurements were collected. Compared to the FPG criterion, the sensitivity of HbA1c ≥ 6.5% was only 43.3% (106 subjects). Compared to the 2hPG criterion, the sensitivity of HbA1c ≥ 6.5% was only 28.1% (110 subjects). Patients who were diabetic using 2hPG criterion but had HbA1c HbA1c ≥ 6.5%. The diagnostic agreement in the clinical setting revealed the current HbA1c ≥ 6.5% is less likely to detect diabetes than those defined by FPG and 2hPG. HbA1c ≥ 6.5% detects less than 50% of diabetic patients defined by FPG and less than 30% of diabetic patients defined by 2hPG. When the diagnosis of diabetes is in doubt by HbA1c, FPG and/or 2hPG should be obtained. PMID:27597979

  16. The HbA1c and All-Cause Mortality Relationship in Patients with Type 2 Diabetes is J-Shaped: A Meta-Analysis of Observational Studies

    Science.gov (United States)

    Arnold, Luke W.; Wang, Zhiqiang

    2014-01-01

    BACKGROUND: Low blood glucose and HbA1c levels are recommended in the literature on management of diabetes. However, data have shown that low blood glucose is associated with serious adverse effects for the patients and the recommendation has been criticized. Therefore, this article revisits the relationship between HbA1c and all-cause mortality by a meta-analysis of observational studies. AIM: The aim of this study is to determine whether there is a J- or U-shaped non-linear relationship between HbA1c and all-cause mortality in type 2 diabetes patients, implying an increased risk to premature all-cause mortality at high and low levels of HbA1c. METHODS: A comprehensive literature search was conducted using PubMed, Medline, and Cochrane Library databases with strict inclusion/exclusion criteria. The published adjusted hazard ratios (HR) with 95% confidence intervals of all-cause mortality for each HbA1c category and per study were analyzed. Fractional polynomial regression was used with random effect modeling to assess the non-linear relationship of the HR trends between studies. Seven eligible observational studies with a total of 147,424 participants were included in the study. RESULTS: A significant J-shaped relationship was observed between HbA1c and all-cause mortality. Crude relative risk for all-cause mortality identified a decreased risk per 1% increase in HbA1c below 7.5% (58 mmol/mol) (0.90, CI 0.86-0.94) and an increased risk per 1% increase in HbA1c above 7.5% (58 mmol/mol) (1.04, CI 1.01-1.06). Observational studies revealed a J-shaped relationship between HbA1c and all-cause mortality, equivalent to an increased risk of mortality at high and low HbA1c levels. CONCLUSIONS: This increased mortality at high and low HbA1c levels has significant implications on investigating optimum clinical HbA1c targets as it suggests that there are upper and lower limits for creating a 'security zone' for diabetes management. PMID:25396402

  17. HbA1c Test as a Tool in the Diagnosis of Gestational Diabetes Mellitus.

    Directory of Open Access Journals (Sweden)

    Paula Breitenbach Renz

    Full Text Available Gestational diabetes mellitus (GDM is a prevalent and potentially serious condition which may put both mothers and neonates at risk. The current recommendation for diagnosis is the oral glucose tolerance test (OGTT. This study aimed to determine the usefulness of HbA1c test as a diagnostic tool for GDM as compared to the traditional criteria based on the OGTT.This was a diagnostic test accuracy study. We performed OGTT and HbA1c test in women attending prenatal visits at a tertiary hospital. GDM was defined according to WHO1999 or ADA/WHO 2013 criteria. ROC curve was used to evaluate the diagnostic performance of HbA1c. Sensitivity, specificity and likelihood ratios for different HbA1c cut-off points were calculated.Of the 262 women in the third trimester of gestation enrolled in the study, 86 (33% were diagnosed with GDM. Only five of these women presented HbA1c ≥48 mmol/mol (6.5%. This cut-off point presented 100% specificity but very low sensitivity (7%. Based on ROC curve, and considering OGTT as the reference criterion, HbA1c ≥40 mmol/mol (5.8% showed adequate specificity in diagnosing GDM (94.9% but low sensitivity (26.4%. Unlike, HbA1c values of 31 mmol/mol (5.0% presented adequate sensitivity (89.7% but low specificity (32.6% to detect GDM. For women with HbA1c ≥40 mmol/mol (5.8%, the positive and negative likelihood ratios were 5.14 (95%CI 2.49-10.63 and 0.78 (0.68-0.88, respectively. The post-test probability of GDM was about 40%, representing a 4.0-fold increase in the mean pre-test probability. This cut-off point could eliminate the need for the unpleasant and laborious OGTT tests in almost one third of cases, as 38% of patients with GDM may be diagnosable by HbA1c test alone.Our results show that combined HbA1c and OGTT measurements may be useful in diagnosing GDM.

  18. Experimental measurements at the MASURCA facility

    International Nuclear Information System (INIS)

    Assal, W.; Bosq, J.C.; Mellier, F.

    2012-01-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, MASURCA (meaning 'mock-up facility for fast breeder reactor studies at Cadarache') is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems). For this purpose are implemented electronics modules to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electric and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at MASURCA will be presented. (authors)

  19. Experimental Measurements at the MASURCA Facility

    Science.gov (United States)

    Assal, W.; Bosq, J. C.; Mellier, F.

    2012-12-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, MASURCA (meaning “mock-up facility for fast breeder reactor studies at CADARACHE”) is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems ...). For this purpose are implemented electronics modules to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electric and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at MASURCA will be presented.

  20. Experimental measurements at the Masurca facility

    International Nuclear Information System (INIS)

    AssaI, W.; Bosq, J. C.; Mellier, F.

    2009-01-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, Masurca (meaning 'mock-up facility for fast breeder reactor studies at Cadarache') is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems...). For this purpose electronics modules are implemented to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electrical and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at Masurca will be presented. (authors)

  1. Regulatory measures of BARC Safety Council to control radiation exposure in BARC Facilities

    International Nuclear Information System (INIS)

    Rajdeep; Jolly, V.M.; Jayarajan, K.

    2018-01-01

    Bhabha Atomic Research Centre is involved in multidisciplinary research and developmental activities, related to peaceful use of nuclear energy including societal benefits. BARC facilities at different parts of India include nuclear fuel fabrication facilities, research reactors, nuclear recycle facilities and various Physics, Chemistry and Biological laboratories. BARC Safety Council (BSC) is the regulatory body for BARC facilities and takes regulatory measures for radiation protection. BSC has many safety committees for radiation protection including Operating Plants Safety Review Committee (OPSRC), Committee to Review Applications for Authorization of Safe Disposal of Radioactive Wastes (CRAASDRW) and Design Safety Review Committees (DSRC) in 2 nd tier and Unit Level Safety Committees (ULSCs) in 3 rd tier under OPSRC

  2. Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method.

    Science.gov (United States)

    Grant, D A; Dunseath, G J; Churm, R; Luzio, S D

    2017-08-01

    As the use of Point of Care Testing (POCT) devices for measurement of glycated haemoglobin (HbA1c) increases, it is imperative to determine how their performance compares to laboratory methods. This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics), which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC) method (Biorad D10) for measurement of HbA1c. Whole blood EDTA samples from subjects (n=100) with and without diabetes were assayed using a BioRad D10 and a Quo-Test analyser. Intra-assay variation was determined by measuring six HbA1c samples in triplicate and inter-assay variation was determined by assaying four samples on 4 days. Stability was determined by assaying three samples stored at -20 °C for 14 and 28 days post collection. Median (IQR) HbA1c was 60 (44.0-71.2) mmol/mol (7.6 (6.17-8.66) %) and 62 (45.0-69.0) mmol/mol (7.8 (6.27-8.46) %) for D10 and Quo-Test, respectively, with very good agreement (R 2 =0.969, Pglucose intolerance (IGT and T2DM) and 100% for diagnosis of T2DM. Good agreement between the D10 and Quo-Test was seen across a wide HbA1c range. The Quo-Test POCT device provided similar performance to a laboratory based HPLC method.

  3. Gas temperature measurements in short duration turbomachinery test facilities

    Science.gov (United States)

    Cattafesta, L. N.; Epstein, A. H.

    1988-07-01

    Thermocouple rakes for use in short-duration turbomachinery test facilities have been developed using very fine thermocouples. Geometry variations were parametrically tested and showed that bare quartz junction supports (76 microns in diameter) yielded superior performance, and were rugged enough to survive considerable impact damage. Using very low cost signal conditioning electronics, temperature accuracies of 0.3 percent were realized yielding turbine efficiency measurements at the 1-percent level. Ongoing work to improve this accuracy is described.

  4. A targetable HB-EGF-CITED4 axis controls oncogenesis in lung cancer.

    Science.gov (United States)

    Hsieh, C-H; Chou, Y-T; Kuo, M-H; Tsai, H-P; Chang, J-L; Wu, C-W

    2017-05-25

    Aberrant epidermal growth factor (EGF) receptor (EGFR) signaling contributes to neoplastic initiation and progression in lung. Mutated EGFR has become as an important therapeutic target in lung cancer, whereas targeted treatment is not available for wild-type EGFR or its ligands. In this study, we found that heparin-binding (HB)-EGF, a member of the EGF family, was highly expressed in a subset of lung cancer, proliferation of which was dependent on HB-EGF signaling. Silencing of HB-EGF with RNA interference inhibited cell cycle progression in lung cancer cells. We observed that, upon HB-EGF induction, CITED4 was induced through a signal transducer and activator of transcription 3 (STAT3)-dependent pathway, regulating cell proliferation. CITED4 interacted with MYC and potentiated MYC-mediated transactivation of the CCND1 promoter, leading to cell cycle progression. Correlation analysis revealed that HB-EGF and CITED4 were significantly positively associated in primary lung tumors, and expression of HB-EGF predicted a poor survival outcome in patients. In vitro and in vivo experiments revealed that pharmacological inhibition of HB-EGF with CRM197 significantly attenuated tumor cell growth. Thus, CITED4 functions as a molecular switch in HB-EGF-induced growth control, and HB-EGF provides a novel therapeutic target for lung cancer intervention.

  5. Non-invasive measurements of carboxyhemoglobin and methemoglobin in children with sickle cell disease.

    Science.gov (United States)

    Caboot, Jason B; Jawad, Abbas F; McDonough, Joseph M; Bowdre, Cheryl Y; Arens, Raanan; Marcus, Carole L; Mason, Thornton B A; Smith-Whitley, Kim; Ohene-Frempong, Kwaku; Allen, Julian L

    2012-08-01

    Assessment of oxyhemoglobin saturation in patients with sickle cell disease (SCD) is vital for prompt recognition of hypoxemia. The accuracy of pulse oximeter measurements of blood oxygenation in SCD patients is variable, partially due to carboxyhemoglobin (COHb) and methemoglobin (MetHb), which decrease the oxygen content of blood. This study evaluated the accuracy and reliability of a non-invasive pulse co-oximeter in measuring COHb and MetHb percentages (SpCO and SpMet) in children with SCD. We hypothesized that measurements of COHb and MetHb by non-invasive pulse co-oximetry agree within acceptable clinical accuracy with those made by invasive whole blood co-oximetry. Fifty children with SCD-SS underwent pulse co-oximetry and blood co-oximetry while breathing room air. Non-invasive COHb and MetHb readings were compared to the corresponding blood measurements. The pulse co-oximeter bias was 0.1% for COHb and -0.22% for MetHb. The precision of the measured SpCO was ± 2.1% within a COHb range of 0.4-6.1%, and the precision of the measured SpMet was ± 0.33% within a MetHb range of 0.1-1.1%. Non-invasive pulse co-oximetry was useful in measuring COHb and MetHb levels in children with SCD. Although the non-invasive technique slightly overestimated the invasive COHb measurements and slightly underestimated the invasive MetHb measurements, there was close agreement between the two methods. Copyright © 2012 Wiley Periodicals, Inc.

  6. Aldimine Formation Reaction, the First Step of the Maillard Early-phase Reaction, Might be Enhanced in Variant Hemoglobin, Hb Himeji.

    Science.gov (United States)

    Koga, Masafumi; Inada, Shinya; Shimizu, Sayoko; Hatazaki, Masahiro; Umayahara, Yutaka; Nishihara, Eijun

    2015-01-01

    Hb Himeji (β140Ala→Asp) is known as a variant hemoglobin in which glycation is enhanced and HbA1c measured by immunoassay shows a high value. The phenomenon of enhanced glycation in Hb Himeji is based on the fact that the glycation product of variant hemoglobin (HbX1c) shows a higher value than HbA1c. In this study, we investigated whether aldimine formation reaction, the first step of the Maillard early-phase reaction, is enhanced in Hb Himeji in vitro. Three non-diabetic subjects with Hb Himeji and four non-diabetic subjects without variant hemoglobin were enrolled. In order to examine aldimine formation reaction, whole blood cells were incubated with 500 mg/dl of glucose at 37°C for 1 hour and were analyzed by high-performance liquid chromatography. Both HbA1c and HbX1c were not increased in this condition. After incubation with glucose, labile HbA1c (LA1c) fraction increased in the controls (1.1±0.3%). In subjects with Hb Himeji increases in the labile HbX1c (LX1c) fraction as well as the LA1c fraction were observed, and the degree of increase in the LX1c fraction was significantly higher than that of the LA1c fraction (1.8±0.1% vs. 0.5±0.2%, Preaction might be enhanced in Hb Himeji in vitro. The 140th amino acid in β chain of hemoglobin is suggested to be involved in aldimine formation reaction. © 2015 by the Association of Clinical Scientists, Inc.

  7. One-Hour Postload Hyperglycemia Confers Higher Risk of Hepatic Steatosis to HbA1c-Defined Prediabetic Subjects.

    Science.gov (United States)

    Fiorentino, Teresa Vanessa; Andreozzi, Francesco; Mannino, Gaia Chiara; Pedace, Elisabetta; Perticone, Maria; Sciacqua, Angela; Perticone, Francesco; Sesti, Giorgio

    2016-11-01

    Individuals with glycated hemoglobin (HbA1c)-defined prediabetes (HbA1c value of 5.7-6.4%) and 1-hour plasma glucose ≥155 mg/dL during an oral glucose tolerance test have an increased risk of developing type 2 diabetes. To evaluate the degree to which HbA1c-defined prediabetes and 1-hour postload glucose ≥155 mg/dL individually and jointly associate with hepatic steatosis and related biomarkers. A cross-sectional analysis was performed on 1108 White individuals. Ambulatory care. Anthropometric and metabolic characteristics including hepatic steatosis assessed by ultrasonography. Compared with the normal group (HbA1c prediabetic and diabetic individuals exhibit higher values of fasting, 1-hour, and 2-hour postload glucose; fasting and 2-hour postload insulin; triglycerides; uric acid; homeostasis model of assessment for insulin resistance; liver insulin resistance index; liver enzymes; and inflammatory biomarkers; and lower levels of high-density lipoprotein cholesterol and IGF-1. Prediabetic and diabetic subjects have increased risk of hepatic steatosis (1.5- and 2.46-fold, respectively). Stratifying participants according to HbA1c and 1-hour postload glucose, we found that individuals with HbA1c-defined prediabetes and 1-hour postload glucose ≥155 mg/dL have significantly higher risk of hepatic steatosis as compared with individuals with HbA1c-defined prediabetes but 1-hour postload glucose prediabetes and 1-hour postload glucose ≥155 mg/dL exhibit higher values of liver enzymes; fasting, 1-hour, and 2-hour postload glucose; insulin; triglycerides; uric acid; and inflammatory biomarkers; and lower levels of high-density lipoprotein and IGF-1. These data suggest that a value of 1-hour postload glucose ≥155 mg/dL may be helpful to identify a subset of individuals within HbA1c-defined glycemic categories at higher risk of hepatic steatosis.

  8. High level radioactive waste management facility design criteria

    International Nuclear Information System (INIS)

    Sheikh, N.A.; Salaymeh, S.R.

    1993-01-01

    This paper discusses the engineering systems for the structural design of the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). At the DWPF, high level radioactive liquids will be mixed with glass particles and heated in a melter. This molten glass will then be poured into stainless steel canisters where it will harden. This process will transform the high level waste into a more stable, manageable substance. This paper discuss the structural design requirements for this unique one of a kind facility. A special emphasis will be concentrated on the design criteria pertaining to earthquake, wind and tornado, and flooding

  9. Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method

    OpenAIRE

    Grant, D.A.; Dunseath, G.J.; Churm, R.; Luzio, S.D.

    2017-01-01

    Aims: As the use of Point of Care Testing (POCT) devices for measurement of glycated haemoglobin (HbA1c) increases, it is imperative to determine how their performance compares to laboratory methods. This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics), which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC) method (Biorad D10) for measurement of HbA1c. Methods: Whole blood EDTA samples...

  10. Should we adjust erythropoiesis-stimulating agent dosage to postdialysis hemoglobin levels? A pilot study

    Directory of Open Access Journals (Sweden)

    Castillo Nieves

    2012-07-01

    Full Text Available Abstract Background Predialysis hemoglobin (Hb may overestimate the true erithropoiesis-stimulating agents (ESA requeriments. We tested whether predialysis Hb is a reliable predictor of the postdialysis level to better control ESA dosage, and evaluated the relation between ESA, Hb and cardiovascular events (CVE. Methods Cohort study including 67 stable hemodialysis patients. Pre- and post-dialysis Hb concentrations were measured, and ESA doses were calculated. A model to predict post-dialysis Hb is proposed. During 18 months follow-up, CVE, hospitalizations and mortality were collected. Results After dialysis, Hb cocentration rise by 6.1 ± 5.6%. Using postdialysis Hb, the weight-adjusted ESA dosage would be lower respect to the prescription using predialysis Hb: 104 ± 120 vs 128 ± 124 U/kg/week (P P = 0.001. The prediction model is: Postdialysis Hb (g/dL = 1.636 + 0.871 x predialysis Hb* (g/dL + 0.099 x UF rate** (mL/kg/h - 0.39 for women***. [R2 = 0.74; *P P = 0.001; ***P = 0.03. Conclusions Postdialysis Hb can be a better reflect of the real Hb level in hemodialysis patients. Using postdialysis Hb would avoid the use of inappropriately high ESA doses. The prediction of postdialysis Hb with an adjusted model would help us to identify those patients at risk for ESA overdosification.

  11. Mixed and Low-Level Waste Treatment Facility project

    International Nuclear Information System (INIS)

    1992-04-01

    Mixed and low-level wastes generated at the Idaho National Engineering Laboratory (INEL) are required to be managed according to applicable State and Federal regulations, and Department of Energy Orders that provide for the protection of human health and the environment. The Mixed and Low-Level Waste Treatment Facility Project was chartered in 1991, by the Department of Energy to provide treatment capability for these mixed and low-level waste streams. The first project task consisted of conducting engineering studies to identify the waste streams, their potential treatment strategies, and the requirements that would be imposed on the waste streams and the facilities used to process them. The engineering studies, initiated in July 1991, identified 37 mixed waste streams, and 55 low-level waste streams. This report documents the waste stream information and potential treatment strategies, as well as the regulatory requirements for the Department of Energy-owned treatment facility option. The total report comprises three volumes and two appendices. This report consists of Volume 1, which explains the overall program mission, the guiding assumptions for the engineering studies, and summarizes the waste stream and regulatory information, and Volume 2, the Waste Stream Technical Summary which, encompasses the studies conducted to identify the INEL's waste streams and their potential treatment strategies

  12. Biosecurity measures in 48 isolation facilities managing highly infectious diseases.

    Science.gov (United States)

    Puro, Vincenzo; Fusco, Francesco M; Schilling, Stefan; Thomson, Gail; De Iaco, Giuseppina; Brouqui, Philippe; Maltezou, Helena C; Bannister, Barbara; Gottschalk, René; Brodt, Hans-Rheinhard; Ippolito, Giuseppe

    2012-06-01

    Biosecurity measures are traditionally applied to laboratories, but they may also be usefully applied in highly specialized clinical settings, such as the isolation facilities for the management of patients with highly infectious diseases (eg, viral hemorrhagic fevers, SARS, smallpox, potentially severe pandemic flu, and MDR- and XDR-tuberculosis). In 2009 the European Network for Highly Infectious Diseases conducted a survey in 48 isolation facilities in 16 European countries to determine biosecurity measures for access control to the facility. Security personnel are present in 39 facilities (81%). In 35 facilities (73%), entrance to the isolation area is restricted; control methods include electronic keys, a PIN system, closed-circuit TV, and guards at the doors. In 25 facilities (52%), identification and registration of all staff entering and exiting the isolation area are required. Access control is used in most surveyed centers, but specific lacks exist in some facilities. Further data are needed to assess other biosecurity aspects, such as the security measures during the transportation of potentially contaminated materials and measures to address the risk of an "insider attack."

  13. Excess HB-EGF, which promotes VEGF signaling, leads to hydrocephalus

    Science.gov (United States)

    Shim, Joon W.; Sandlund, Johanna; Hameed, Mustafa Q.; Blazer-Yost, Bonnie; Zhou, Feng C.; Klagsbrun, Michael; Madsen, Joseph R.

    2016-01-01

    Heparin binding epidermal growth factor-like growth factor (HB-EGF) is an angiogenic factor mediating radial migration of the developing forebrain, while vascular endothelial growth factor (VEGF) is known to influence rostral migratory stream in rodents. Cell migratory defects have been identified in animal models of hydrocephalus; however, the relationship between HB-EGF and hydrocephalus is unclear. We show that mice overexpressing human HB-EGF with β-galactosidase reporter exhibit an elevated VEGF, localization of β-galactosidase outside the subventricular zone (SVZ), subarachnoid hemorrhage, and ventriculomegaly. In Wistar polycystic kidney rats with hydrocephalus, alteration of migratory trajectory is detected. Furthermore, VEGF infusions into the rats result in ventriculomegaly with an increase of SVZ neuroblast in rostral migratory stream, whereas VEGF ligand inhibition prevents it. Our results support the idea that excess HB-EGF leads to a significant elevation of VEGF and ventricular dilatation. These data suggest a potential pathophysiological mechanism that elevated HB-EGF can elicit VEGF induction and hydrocephalus. PMID:27243144

  14. Heparin-Binding EGF-like Growth Factor (HB-EGF) stimulates the proliferation of Müller glia-derived progenitor cells in avian and murine retinas

    Science.gov (United States)

    Todd, Levi; Volkov, Leo I.; Zelinka, Chris; Squires, Natalie; Fischer, Andy J.

    2015-01-01

    Müller glia can be stimulated to de-differentiate, proliferate and form Müller glia-derived progenitor cells (MGPCs) that regenerate retinal neurons. In the zebrafish retina, Heparin-Binding EGF-like Growth Factor (HB-EGF) may be one of the key factors that stimulate the formation of proliferating MGPCs. Currently nothing is known about the influence of HB-EGF on the proliferative potential of Müller glia in retinas of birds and rodents. In the chick retina, we found that levels of both hb-egf and egf-receptor are rapidly and transiently up-regulated following NMDA-induced damage. Although intraocular injections of HB-EGF failed to stimulate cell-signaling or proliferation of Müller glia in normal retinas, HB-EGF stimulated proliferation of MGPCs in damaged retinas. By comparison, inhibition of the EGF-receptor (EGFR) decreased the proliferation of MGPCs in damaged retinas. HB-EGF failed to act synergistically with FGF2 to stimulate the formation of MGPCs in the undamaged retina and inhibition of EGF-receptor did not suppress FGF2-mediated formation of MGPCs. In the mouse retina, HB-EGF stimulated the proliferation of Müller glia following NMDA-induced damage. Furthermore, HB-EGF stimulated not only MAPK-signaling in Müller glia/MGPCs, but also activated mTor- and Jak/Stat-signaling. We propose that levels of expression of EGFR are rate-limiting to the responses of Müller glia to HB-EGF and the expression of EGFR can be induced by retinal damage, but not by FGF2-treatment. We conclude that HB-EGF is mitogenic to Müller glia in both chick and mouse retinas, and HB-EGF is an important player in the formation of MGPCs in damaged retinas. PMID:26500021

  15. The importance of haemoglobin level and effect of transfusion in HNSCC patients treated with radiotherapy - Results from the randomized DAHANCA 5 study

    International Nuclear Information System (INIS)

    Hoff, Camilla Molich; Hansen, Hanne Sand; Overgaard, Marie; Grau, Cai; Johansen, Jorgen; Bentzen, Jens; Overgaard, Jens

    2011-01-01

    Background and purpose: Patients with head and neck squamous cell carcinoma (HNSCC) and a low level of haemoglobin (Hb) often have a poor response to radiation which may be related to hypoxia induced radioresistance. The aim of the study was to evaluate the prognostic significance of low Hb level and its modification by transfusion in HNSCC patients treated with radiotherapy. The study was performed as a subrandomization in the DAHANCA 5 trial. Material and methods: Patients were randomized to treatment with the hypoxic radiosensitizer nimorazole or placebo, and in addition, patients with 'low' pre-irradiation Hb values (females < 13 g/dL; males < 14.5 g/dL) were subrandomized to plus or minus transfusion. Transfusion was given with packed red blood cells with the aim to achieve a Hb level in the 'high' value range. Results: A total of 414 patients were included, 243 patients had high Hb levels and 171 patients had low Hb levels. Of the low Hb patients, 82 were randomized to receive transfusion and 89 not to receive transfusion. The treatment arms were well balanced. In the majority of patients, transfusion resulted in increased Hb levels although this tended to decline throughout treatment. Patients with high Hb levels had a significantly better probability of locoregional control, disease-specific survival and overall survival compared to 'low Hb no transfusion' patients. In the low Hb group, transfusion did not improve the outcome in locoregional control, disease-specific survival or overall survival. In multivariate analyses, T and N classifications were significant for all outcome measures, whereas there was no significant influence of transfusion or Hb level on endpoints. Conclusion: The univariate prognostic significance of high Hb level was demonstrated in patients with HNSCC treated with radiotherapy; however, transfusion prior to and during treatment did not improve the outcome in patients with low Hb values.

  16. The sunflower transcription factor HaHB11 improves yield, biomass and tolerance to flooding in transgenic Arabidopsis plants.

    Science.gov (United States)

    Cabello, Julieta V; Giacomelli, Jorge I; Piattoni, Claudia V; Iglesias, Alberto A; Chan, Raquel L

    2016-03-20

    HaHB11 is a member of the sunflower homeodomain-leucine zipper I subfamily of transcription factors. The analysis of a sunflower microarray hybridized with RNA from HaHB11-transformed leaf-disks indicated the regulation of many genes encoding enzymes from glycolisis and fermentative pathways. A 1300bp promoter sequence, fused to the GUS reporter gene, was used to transform Arabidopsis plants showing an induction of expression after flooding treatments, concurrently with HaHB11 regulation by submergence in sunflower. Arabidopsis transgenic plants expressing HaHB11 under the control of the CaMV 35S promoter and its own promoter were obtained and these plants exhibited significant increases in rosette and stem biomass. All the lines produced more seeds than controls and particularly, those of high expression level doubled seeds yield. Transgenic plants also showed tolerance to flooding stress, both to submergence and waterlogging. Carbohydrates contents were higher in the transgenics compared to wild type and decreased less after submergence treatments. Finally, transcript levels of selected genes involved in glycolisis and fermentative pathways as well as the corresponding enzymatic activities were assessed both, in sunflower and transgenic Arabidopsis plants, before and after submergence. Altogether, the present work leads us to propose HaHB11 as a biotechnological tool to improve crops yield, biomass and flooding tolerance. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Effect of once-weekly dulaglutide on glycated haemoglobin (HbA1c) and fasting blood glucose in patient subpopulations by gender, duration of diabetes and baseline HbA1c.

    Science.gov (United States)

    Gallwitz, Baptist; Dagogo-Jack, Samuel; Thieu, Vivian; Garcia-Perez, Luis-Emilio; Pavo, Imre; Yu, Maria; Robertson, Kenneth E; Zhang, Nan; Giorgino, Francesco

    2018-02-01

    To evaluate the efficacy and safety of dulaglutide 1.5 and 0.75 mg in patients with type 2 diabetes by subgroups of gender, duration of diabetes and baseline glycated haemoglobin (HbA1c) in the dulaglutide clinical development programme (AWARD-1 to -6 and -8 clinical trials). Change in HbA1c was analysed by gender, duration of diabetes (baseline HbA1c (baseline in weight, hypoglycaemia and gastrointestinal adverse events were evaluated for individual trials. In the pooled analysis of patients treated with dulaglutide 1.5 mg at 6 months, the reductions in HbA1c from baseline were similar across gender (men: least squares [LS] mean -1.26% [95% confidence interval {CI} -1.36, -1.16]; women: LS mean -1.33% [95% CI -1.43, -1.24]) and among duration of diabetes subgroups (baseline HbA1c ≥8.5% had greater HbA1c reductions than patients with baseline HbA1c baseline HbA1c subgroups, respectively; women had a numerically greater weight loss or less weight gain than men with both dulaglutide doses. There was no clinically meaningful difference in hypoglycaemia trends by gender or duration of diabetes. Hypoglycaemia incidence and rate were generally lower in patients with baseline HbA1c ≥8.5% than in those with baseline HbA1c, with greater HbA1c and FBG reductions in patients with a higher baseline HbA1c. Dulaglutide was well tolerated, with a safety profile similar to other glucagon-like peptide-1 receptor agonists. © 2017 John Wiley & Sons Ltd.

  18. Description and Results: Antenna Measurement Facility Comparisons [Measurements Corner

    DEFF Research Database (Denmark)

    Alberica Saporetti, Maria; Foged, Lars; Sierra Castañer, Manuel

    2017-01-01

    In recent years, formalized facility comparison activities have become important for the documentation and validation of laboratory proficiency and competence and mandatory for achieving accreditation such as that of the International Organization for Standardization (ISO) 17025 or similar...... for Antennas (VISTA) IC1102, including still ongoing campaigns [3]-[5]. Results of these activities have led to improvements in antenna measurement procedures and protocols in facilities and standards [6], [7]. Due to the direct benefits available to the participants, the activities have been very successful...

  19. Modeling Single-Phase PV HB-ZVR Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the PV H-bridge zero voltage rectifier (HB-ZVR) inverter connected to grid and good results are obtained. First, several common topologies of PV inverters are introduced. Then the unipolar PWM control strategy is described for PV HB-ZVR inverter. Third, PLECS is briefly...... introduced. Fourth, the modeling of PV HB-ZVR inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is very powerful tool to real power circuits and it is very easy to simulate LCL filter. They have also verified that the unipolar PWM control...... strategy is feasible to control the PV HB-ZVR inverter....

  20. HB-EGF expression as a potential biomarker of acquired middle ear cholesteatoma.

    Science.gov (United States)

    Xie, Shumin; Wang, Xiaoli; Ren, Hongmiao; Liu, Xiaoyu; Ren, Jihao; Liu, Wei

    2017-08-01

    The heparin-binding epidermal growth factor-like growth factor (HB-EGF) plays an essential role in the development and invasiveness of cholesteatoma. This study may help to realize the molecular mechanisms underlying the pathogenesis of cholesteatoma and make HB-EGF a promising target for drug intervention of cholesteatoma. To detect HB-EGF expression in human surgical specimens of acquired middle ear cholesteatoma and analyze its functional role as a regulator of epithelial keratinocytes hyperproliferation. A total of 34 patients who underwent surgical treatment for middle ear cholesteatoma were recruited in the study. The mRNA and protein expression of HB-EGF in middle ear cholesteatoma tissues and normal postauricular skin tissues was investigated by real-time quantitative reverse-transcription-polymerase chain reaction (RT-qPCR), immunohistochemical staining, and western blot. The correlation between bone resorption degree and HB-EGF expression was also analyzed. On average, compared with normal postauricular skin, expression of HB-EGF mRNA in the cholesteatoma epithelium was significantly elevated 2.41-fold by RT-qPCR, and HB-EGF protein significantly upregulated 2.32-fold by western blot. Positive HB-EGF immunostaining observed in the basal and suprabasal layers of cholesteatoma epithelium was significantly stronger than in normal postauricular skin. Meanwhile, an obviously positive correlation between HB-EGF protein expression and bone resorption degree was discovered.

  1. KADAR HbA1c DAN RASIO LIPID PADA WANITA DEWASA DENGAN OBESITAS SENTRAL

    Directory of Open Access Journals (Sweden)

    Lisa Sudaryanto

    2016-06-01

    Full Text Available Central obesity was accumulation of fat in the abdominal region. Many studies showed correlations between central obesity and cardiovascular diseases, e.g. diabetes and dyslipidemia.  This study was conducted to know the difference between HbA1c and lipid profil between the women with and without central obesity. This study was an analytic observational study with cross-sectional design. Subjects of 52 respondents were healthy adult women staff in campus I, II, III Sanata Dharma University in Yogyakarta and selected using purposive sampling technique. The data of waist circumference, pelvic/hip circumference, HbA1c and lipid profile were collected among the subjects and analyzed with computer with 95% confidence interval. The results of this study showed HbA1c levels and lipid profile were different between the women with and without central obesity, although the difference was not statistically significant.

  2. New diagnostic criteria for diabetes: is the change from glucose to HbA1c possible in all populations?

    DEFF Research Database (Denmark)

    Jørgensen, Marit Eika; Bjerregaard, Peter; Borch-Johnsen, Knut

    2010-01-01

    Recently, a change of the diagnostic tool for diabetes from an oral glucose tolerance test (OGTT) to hemoglobin A1c (HbA1c) has been suggested. The aim of the study was to assess whether ethnicity modified the association between glucose levels and HbA1c and to compare diabetes prevalence accordi...

  3. New diagnostic criteria for diabetes: is the change from glucose to HbA1c possible in all populations?

    DEFF Research Database (Denmark)

    Jørgensen, Marit Eika; Bjerregaard, Peter; Borch-Johnsen, Knut

    2010-01-01

    Recently, a change of the diagnostic tool for diabetes from an oral glucose tolerance test (OGTT) to hemoglobin A1c (HbA1c) has been suggested. The aim of the study was to assess whether ethnicity modified the association between glucose levels and HbA1c and to compare diabetes prevalence according...

  4. Carbonyl Functionalized Single-Walled Carbon Nanotube-Hb Crosslinked Network: A Novel Platform for Studying Bio-Electrochemistry and Electrocatalysis of Hemoglobin.

    Science.gov (United States)

    Kafi, A K M; Yam, C C L; Azmi, N S; Yusoff, Mashitah M

    2018-04-01

    In this work, the direct electrochemistry of hemoglobin (Hb), which was immobilized on carbonyl functionalized single walled carbon nanotube (SWCNT) and deposited onto a gold (Au) electrode has been described. The synthesis of the network of crosslinked SWCNT/Hb was done with the help of crosslinking agent EDC (1-ethyl-3-(3-dimethylaminopropyl) carbodiimide). The UV-Vis and FTIR spectroscopy of SWCNT/Hb networks showed that Hb maintained its natural structure and kept good stability. In addition with this, scanning electron microscopy (SEM) illustrated that SWCNT/Hb networks had a featured layered structure and Hb being strongly liked with SWCNT surface. Cyclic voltammetry (CV) was used to study and to optimize the performance of the resulting modified electrode. The cyclic voltammetric (CV) responses of SWCNT/Hb networks in pH 7.0 exhibit prominent redox couple for the FeIII/II redox process with a midpoint potential of -0.46 V and -0.34, cathodic and anodic respectively. Furthermore, SWCNT/Hb networks are utilized for the detection of hydrogen peroxide (H2O2). Electrochemical measurements reveal that the resulting SWCNT/Hb electrodes display high electrocatalytic activity to H2O2 with high sensitivity, wide linear range, and low detection limit. Overall, the electrochemical results are due to excellent biocompatibility and excellent electron transport efficiency of CNT as well as high Hb loading and synergistic catalytic effect of the modified electrode toward H2O2.

  5. Selecting a Risk-Based SQC Procedure for a HbA1c Total QC Plan.

    Science.gov (United States)

    Westgard, Sten A; Bayat, Hassan; Westgard, James O

    2017-09-01

    Recent US practice guidelines and laboratory regulations for quality control (QC) emphasize the development of QC plans and the application of risk management principles. The US Clinical Laboratory Improvement Amendments (CLIA) now includes an option to comply with QC regulations by developing an individualized QC plan (IQCP) based on a risk assessment of the total testing process. The Clinical and Laboratory Standards Institute (CLSI) has provided new practice guidelines for application of risk management to QC plans and statistical QC (SQC). We describe an alternative approach for developing a total QC plan (TQCP) that includes a risk-based SQC procedure. CLIA compliance is maintained by analyzing at least 2 levels of controls per day. A Sigma-Metric SQC Run Size nomogram provides a graphical tool to simplify the selection of risk-based SQC procedures. Current HbA1c method performance, as demonstrated by published method validation studies, is estimated to be 4-Sigma quality at best. Optimal SQC strategies require more QC than the CLIA minimum requirement of 2 levels per day. More complex control algorithms, more control measurements, and a bracketed mode of operation are needed to assure the intended quality of results. A total QC plan with a risk-based SQC procedure provides a simpler alternative to an individualized QC plan. A Sigma-Metric SQC Run Size nomogram provides a practical tool for selecting appropriate control rules, numbers of control measurements, and run size (or frequency of SQC). Applications demonstrate the need for continued improvement of analytical performance of HbA1c laboratory methods.

  6. Predictive ability of visit-to-visit variability in HbA1c and systolic blood pressure for the development of microalbuminuria and retinopathy in people with type 2 diabetes.

    Science.gov (United States)

    Takao, Toshiko; Suka, Machi; Yanagisawa, Hiroyuki; Matsuyama, Yutaka; Iwamoto, Yasuhiko

    2017-06-01

    We explored whether visit-to-visit variability in both glycated hemoglobin (HbA1c) and systolic blood pressure (SBP) simultaneously predicted the development of microalbuminuria and retinopathy, and whether the predictive ability of these measurements changed according to mean HbA1c and SBP levels in people with type 2 diabetes. A retrospective observational cohort study was conducted on 243 type 2 diabetes patients with normoalbuminuria and 486 without retinopathy at the first visit and within 1year thereafter. The two cohorts were followed up from 1995 until 2012. Multivariate and stratified analyses were performed using Cox proportional hazard models. Microalbuminuria developed in 84 patients and retinopathy in 108. Hazard ratios (HRs) for the development of microalbuminuria associated with the coefficient of variation (CV) and variation independent of mean (VIM) of both HbA1c and SBP significantly increased. In participants with a mean SBP HbA1c were abruptly elevated and significant compared with those with a mean SBP ≥130mmHg. Visit-to-visit variability in both HbA1c and SBP simultaneously predict the development of microalbuminuria. HbA1c variability may predict the development of retinopathy when the mean SBP is normal (<130mmHg). Copyright © 2017 Elsevier B.V. All rights reserved.

  7. HUBUNGAN KADAR PB DENGAN KADAR HB PADA ANAK DI WILAYAH DAUR ULANG AKI BEKAS INFORMAL DI BOGOR, DEPOK, TANGERANG, DAN BEKASI

    Directory of Open Access Journals (Sweden)

    Inswiasri Inswiasri

    2016-10-01

    Full Text Available ABSTRACT The increasing number of unofficial dry battery recycling done by households and small industries could have an impact on public health. During the recycling process there will be Pb emissions (battery major component into the air. Pb exposure, especially to children can cause health effects such as anemia microcytic and hyprochromic. This study aims to discover the effect of Pb exposure from used batteries recycling on the cases of children with anemia (aged 7-13 years in Bogor, Depok, Tangerang, and Bekasi in the year 2014. Study design was cross-sectional, with the sample of children as many as 418. Levels of lead in children's blood was measured using Lead Care Analyzer II, and hemoglobin levels in the blood with Hemoque 2.1. The results showed that 36.6% of children suffer from anemia. The test results indicate a statistically significant relationship (p <0.05 between Pb levels in the blood with anemia (low Hb levels; with a very weak correlation (correlation coefficient: 0.124. Need more thorough studies on aspects of health impacts from battery recycling. Keywords: Battery recycling, lead (Pb, haemoglobin, children   ABSTRAK Pajanan Pb terutama terhadap anak-anak dapat menimbulkan dampak kesehatan berupa anemia microcytic dan hyprochromic. Penelitian ini dilakukan untuk mengetahui pengaruh pajanan Pb dari kegiatan daur ulang aki bekas terhadap kejadian anemia anak-anak (usia 7–13 tahun di Bogor, Depok, Tangerang, dan Bekasi, tahun 2014. Desain penelitian adalah potong lintang, dengan jumlah sampel anak-anak sebanyak 418 orang. Kadar Pb dalam darah anak-anak diukur dengan menggunakan Lead Care Analyzer II, dan kadar Hb dalam darah dengan Hemoque 2.1. Hasil penelitian menunjukkan bahwa 36,6% anak-anak menderita anemia. Hasil uji statistik mengindikasikan adanya hubungan yang signifikan (p<0,05 antara kadar Pb dalam darah dengan kejadian anemia (kadar Hb rendah; dengan korelasi sangat lemah (koefisien korelasi: 0,124. Perlu

  8. ERGEBNISSE DER UNTERSUCHUNG VON HB-AL BEI 94 PATIENTEN MIT NIERENINSUFFIZIENZ

    Directory of Open Access Journals (Sweden)

    A

    1983-05-01

    Full Text Available We have qua nt i t a l ed Hb- Al ~n 125 patients . 74 pa t ient s had chronic Renal Failure . 20 of them had Diabetes wi th Renal Fai lure , 21 Diabetics and 10 patients were evaluat ed as control. We have divided the patients with Renal Failure i n 3 groups according to t heir serum c reatin i ne . Hb-Al in a ll groups "as not correlated wi th serum creat i ne. Hb-Al in Diabetic gr oup was highe r than Diabetic patients with Renal Failure . This group a lso had mor e HbA1 than t he gr oup with Renal ~ailure a nd no Diabetes ,and control group . , Hb-Al was correlated with Blood suger i n all pa t i e nt s s o we can u se"nal Failure the me a sureme nt of Hb-Al i n pati ents with Renunder Dial ys i s with gl ucose solution fo r evalua t i o n of sugar meta boli s m.  

  9. Patient safety in maternal healthcare at secondary and tertiary level facilities in Delhi, India

    Directory of Open Access Journals (Sweden)

    Chandrakant Lahariya

    2015-01-01

    Full Text Available Background: There is insufficient information on causes of unsafe care at facility levels in India. This study was conducted to understand the challenges in government hospitals in ensuring patient safety and to propose solutions to improve patient care. Materials and Methods: Desk review, in-depth interviews, and focused group discussions were conducted between January and March 2014. Healthcare providers and nodal persons for patient safety in Gynecology and Obstetrics Departments of government health facilities from Delhi state of India were included. Data were analyzed using qualitative research methods and presented adopting the "health system approach." Results: The patient safety was a major concern among healthcare providers. The key challenges identified were scarcity of resources, overcrowding at health facilities, poor communications, patient handovers, delay in referrals, and the limited continuity of care. Systematic attention on the training of care providers involved in service delivery, prescription audits, peer reviews, facility level capacity building plan, additional financial resources, leadership by institutional heads and policy makers were suggested as possible solutions. Conclusions: There is increasing awareness and understanding about challenges in patient safety. The available local information could be used for selection, designing, and implementation of measures to improve patient safety at facility levels. A systematic and sustained approach with attention on all functions of health systems could be beneficial. Patient safety could be used as an entry point to improve the quality of health care services in India.

  10. Relationship of HbA1c variability, absolute changes in HbA1c, and all-cause mortality in type 2 diabetes

    DEFF Research Database (Denmark)

    Skriver, Mette Vinther; Sandbæk, Annelli; Kristensen, Jette Kolding

    2015-01-01

    OBJECTIVE: We assessed the relationship of mortality with glycated hemoglobin (HbA1c) variability and with absolute change in HbA1c. DESIGN: A population-based prospective observational study with a median follow-up time of 6 years. METHODS: Based on a validated algorithm, 11 205 Danish individua...

  11. Primary and booster vaccination with DTPw-HB/Hib pentavalent vaccine in Costa Rican children who had received a birth dose of hepatitis B vaccine

    Directory of Open Access Journals (Sweden)

    Idis Faingezicht

    2002-10-01

    Full Text Available Objective. The DTPw-HB/Hib pentavalent combination vaccine has been developed following recommendations of the World Health Organization for the introduction of hepatitis B (HB and Haemophilus influenzae type b (Hib vaccines into routine childhood vaccination programs. The objectives of this study were to: 1 analyze the immunogenicity and the reactogenicity of the DTPw-HB/Hib pentavalent combination vaccine in comparison to separate injections of DTPw-HB and Hib vaccines as primary vaccination in a group of children who had received a dose of HB vaccine at birth and 2 in the second year of life to assess the antibody persistence as well as the response to a DTPw-HB/Hib or DTPw/Hib booster. Methods. In the first part of the study (primary-vaccination stage, conducted in 1998-1999, we analyzed the immunogenicity and reactogenicity of the DTPw-HB/Hib combination vaccine in comparison to separate injections of DTPw-HB and Hib vaccines as primary vaccination at 2, 4, and 6 months of age in 207 Costa Rican children who had received a dose of HB vaccine at birth. Later, in the booster-vaccination stage of the study, in 1999-2000, in a subset of the children (69 toddlers, now 15-18 months old, antibody persistence was measured, and response to a DTPw-HB/Hib or DTPw/Hib booster was also assessed. Results. In both primary-vaccination groups, at least 97.5% of the infants reached protective levels of antibodies (seropositivity against the antigens employed in the vaccines. The DTPw-HB/Hib pentavalent combination vaccine did not result in more local reactions than did the DTPw-HB vaccine alone, and, in terms of general reactions, there was no clinically significant difference between the combination or separate injections, and with the pentavalent vaccine having the benefit of needing one less injection. Nine months after the third dose of the primary-vaccination course, antibody persistence was similar in both groups, with over 93% of children still having

  12. Percentiles of fasting serum insulin, glucose, HbA1c and HOMA-IR in pre-pubertal normal weight European children from the IDEFICS cohort.

    Science.gov (United States)

    Peplies, J; Jiménez-Pavón, D; Savva, S C; Buck, C; Günther, K; Fraterman, A; Russo, P; Iacoviello, L; Veidebaum, T; Tornaritis, M; De Henauw, S; Mårild, S; Molnár, D; Moreno, L A; Ahrens, W

    2014-09-01

    The aim of this study is to present age- and sex-specific reference values of insulin, glucose, glycosylated haemoglobin (HbA1c) and the homeostasis model assessment to quantify insulin resistance (HOMA-IR) for pre-pubertal children. The reference population consists of 7074 normal weight 3- to 10.9-year-old pre-pubertal children from eight European countries who participated in at least one wave of the IDEFICS ('identification and prevention of dietary- and lifestyle-induced health effects in children and infants') surveys (2007-2010) and for whom standardised laboratory measurements were obtained. Percentile curves of insulin (measured by an electrochemiluminescence immunoassay), glucose, HbA1c and HOMA-IR were calculated as a function of age stratified by sex using the general additive model for location scale and shape (GAMLSS) method. Levels of insulin, fasting glucose and HOMA-IR continuously show an increasing trend with age, whereas HbA1c shows an upward trend only beyond the age of 8 years. Insulin and HOMA-IR values are higher in girls of all age groups, whereas glucose values are slightly higher in boys. Median serum levels of insulin range from 17.4 and 13.2 pmol l(-1) in 3-HOMA-IR, median values range from 0.5 and 0.4 in 3-<3.5-year-old girls and boys to 1.7 and 1.4 in 10.5-<11-year-old girls and boys, respectively. Our study provides the first standardised reference values for an international European children's population and provides the, up to now, largest data set of healthy pre-pubertal children to model reference percentiles for markers of insulin resistance. Our cohort shows higher values of Hb1Ac as compared with a single Swedish study while our percentiles for the other glucose metabolic markers are in good accordance with previous studies.

  13. beta-Thalassemia present in cis to a new beta-chain structural variant, Hb Vicksburg [beta 75 (E19)Leu leads to 0].

    Science.gov (United States)

    Adams, J G; Steinberg, M H; Newman, M V; Morrison, W T; Benz, E J; Iyer, R

    1981-01-01

    Hemoglobin Vicksburg was discovered in a 6-year-old Black boy who had been anemic since infancy. Examination of his hemolysate revealed 87.5% Hb F, 2.4% Hb A2, and 7.6% Hb Vicksburg, which had the electrophoretic and chromatographic properties of Hb A. Structural analysis of Hb Vicksburg demonstrated a deletion of leucine at beta 75(E19), a new variant. Hb Vicksburg was neither unstable nor subject to posttranslational degradation. The alpha/non-alpha biosynthetic ratio was 2.6. Because the proband appeared to be a mixed heterozygote for Hb Vicksburg and beta 0-thalassemia, Hb Vicksburg should have comprised the major portion of the hemolysate. Thus, Hb Vicksburg was synthesized at a rate considerably lower than would be expected on the basis of gene dosage. There was no reason to suspect abnormal translation of beta Vicksburg mRNA; in individuals with Hb St. Antoine (beta 74 and beta 75 deleted), the abnormal hemoglobin comprised 25% of the hemolysate in the simple heterozygote yet was unstable. Deletion of beta 75, therefore, would not in itself appear to lead to diminished synthesis. There was a profound deficit of beta Vicksburg mRNA when measured by liquid hybridization analysis with beta cDNA. The most plausible explanation for the low output of Hb Vicksburg is that a mutation for beta +-thalassemia is present in cis to the structural mutation.

  14. Pretransplant HbA1c Is a Useful Predictor for the Development of New-Onset Diabetes in Renal Transplant Recipients Receiving No or Low-Dose Erythropoietin

    Directory of Open Access Journals (Sweden)

    Kazuaki Tokodai

    2014-01-01

    Full Text Available Aims. To evaluate the predictive power of pretransplant HbA1c for new-onset diabetes after transplantation (NODAT in kidney transplant candidates, who had several predispositions for fluctuated HbA1c levels. Methods. We performed a retrospective study of 119 patients without diabetes who received kidney transplantation between March 2000 and January 2012. Univariate and multivariate logistic regression analyses were used to investigate the association of several parameters with NODAT. Predictive discrimination of HbA1c was assessed using a receiver-operating characteristic curve. Results. Seventeen patients (14.3% developed NODAT within 1 year of transplantation. Univariate logistic regression analysis revealed that recipient age, gender, and HbA1c were predictors of NODAT. In the multivariate analysis, the association between pretransplant HbA1c and NODAT development did not reach statistical significance (P=0.07. To avoid the strong influence of high-dose erythropoietin on HbA1c levels, we performed subgroup analyses on 85 patients receiving no or low-dose (≤6000 IU/week erythropoietin. HbA1c was again an independent predictor for NODAT. Receiver-operating characteristic analysis revealed a cut-off value of 5.2% with an optimal sensitivity of 64% and specificity of 78% for predicting NODAT. Conclusions. Our results reveal that the pretransplant HbA1c level is a useful predictor for NODAT in patients receiving no or low-dose erythropoietin.

  15. Temperature Measurements in the Magnetic Measurement Facility

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the

  16. Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method

    Directory of Open Access Journals (Sweden)

    D.A. Grant

    2017-08-01

    Full Text Available Aims: As the use of Point of Care Testing (POCT devices for measurement of glycated haemoglobin (HbA1c increases, it is imperative to determine how their performance compares to laboratory methods. This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics, which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC method (Biorad D10 for measurement of HbA1c. Methods: Whole blood EDTA samples from subjects (n=100 with and without diabetes were assayed using a BioRad D10 and a Quo-Test analyser. Intra-assay variation was determined by measuring six HbA1c samples in triplicate and inter-assay variation was determined by assaying four samples on 4 days. Stability was determined by assaying three samples stored at −20 °C for 14 and 28 days post collection. Results: Median (IQR HbA1c was 60 (44.0–71.2 mmol/mol (7.6 (6.17–8.66 % and 62 (45.0–69.0 mmol/mol (7.8 (6.27–8.46 % for D10 and Quo-Test, respectively, with very good agreement (R2=0.969, P<0.0001. Mean (range intra- and inter-assay variation was 1.2% (0.0–2.7% and 1.6% (0.0–2.7% for the D10 and 3.5% (0.0–6.7% and 2.7% (0.7–5.1% for the Quo-Test. Mean change in HbA1c after 28 days storage at −20 °C was −0.7% and +0.3% for D10 and Quo-Test respectively. Compared to the D10, Quo-Test showed 98% agreement for diagnosis of glucose intolerance (IGT and T2DM and 100% for diagnosis of T2DM. Conclusion: Good agreement between the D10 and Quo-Test was seen across a wide HbA1c range. The Quo-Test POCT device provided similar performance to a laboratory based HPLC method. Keywords: Point of care testing, HbA1c measurement

  17. Development of High-Level Safety Requirements for a Pyroprocessing Facility

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Seok Jun; Jo, Woo Jin; You, Gil Sung; Choung, Won Myung; Lee, Ho Hee; Kim, Hyun Min; Jeon, Hong Rae; Ku, Jeong Hoe; Lee, Hyo Jik [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Korea Atomic Energy Research Institute (KAERI) has been developing a pyroproceesing technology to reduce the waste volume and recycle some elements. The pyroprocessing includes several treatment processes which are related with not only radiological and physical but also chemical and electrochemical properties. Thus, it is of importance to establish safety design requirements considering all the aspects of those properties for a reliable pyroprocessing facility. In this study, high-level requirements are presented in terms of not only radiation protection, nuclear criticality, fire protection, and seismic safety but also confinement and chemical safety for the unique characteristics of a pyroprocessing facility. Several high-level safety design requirements such as radiation protection, nuclear criticality, fire protection, seismic, confinement, and chemical processing were presented for a pyroprocessing facility. The requirements must fulfill domestic and international safety technology standards for a nuclear facility. Furthermore, additional requirements should be considered for the unique electrochemical treatments in a pyroprocessing facility.

  18. Comparing incident diabetes as defined by fasting plasma glucose or by HbA(1c). The AusDiab, Inter99 and DESIR studies

    DEFF Research Database (Denmark)

    Soulimane, S.; Simon, D.; Shaw, J. E.

    2011-01-01

    by the corresponding criteria. Despite Diabetes Control and Complications Trial-alignment of the three HbA(1c) assays, there was a large difference in the HbA(1c) distributions between these studies, conducted some 10 years ago. Thus, it is difficult to compare absolute values of diabetes prevalence and incidence...... based on HbA(1c) measurements from that time....

  19. Association between effort-reward imbalance and glycosylated hemoglobin (HbA1c) among Chinese workers: results from SHISO study.

    Science.gov (United States)

    Xu, Weixian; Hang, Juan; Gao, Wei; Zhao, Yiming; Li, Weihong; Wang, Xinyu; Li, Zhaoping; Guo, Lijun

    2012-02-01

    The studies focusing on effort-reward imbalance and diabetes mellitus (DM)/glycosylated hemoglobin (HbA1c) are rare. We sought to examine the association between job stress evaluated by effort-reward imbalance (ERI) model and HbA1c in a Chinese population. We analyzed 680 subjects (465 men and 215 women) without DM or impaired glucose tolerance from the stress and health in Shenzhen workers (SHISO) study. Job stress was evaluated by effort-reward imbalance (ERI) model. HbA1c was measured by an automatic analyzer by means of high-performance liquid chromatography. The association between job stress and HbA1c was explored by variance analysis, partial correlations and multiple linear regression analysis. For women, effort, and ERI were positively associated with HbA1c (r = 0.22, p = 0,003; r = 0.21, p = 0.006, respectively), in contrast, reward was negatively associated with HbA1c (r = -0.17, p = 0.021), after controlling age, BMI and physical exercise in the partial correlation analysis; the similar results were confirmed in the multiple linear regression. No significant correlations between job stress and HbA1c were found for men. Effort and ERI are positively associated with HbA1c, and reward is inversely related to HbA1c among Chinese women. The association is not accounted for by age, BMI, and physical exercise. More efforts should be made to improve the job stress status of Chinese working women for the purpose of DM prevention.

  20. Self-knowledge of HbA1c in people with Type 2 Diabetes Mellitus and its association with glycaemic control

    NARCIS (Netherlands)

    Trivedi, Hina; Gray, Laura J.; Seidu, Samuel; Davies, Melanie J.; Charpentier, Guillaume; Lindblad, Ulf; Kellner, Christiane; Nolan, John J.; Pazderska, Agnieszka; Rutten, Guy; Trento, Marina; Khunti, Kamlesh

    2017-01-01

    Objective The aim of this study was to evaluate the prevalence of accurate self-knowledge of a patient's own HbA1c level (HbA1cSK), as a component of structural education (University Hospital's of Leicester (UHL), 2013) and its association with glycaemic control. Methods Data from the GUIDANCE

  1. Conceptual Design Report for Remote-Handled Low-Level Waste Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lisa Harvego; David Duncan; Joan Connolly; Margaret Hinman; Charles Marcinkiewicz; Gary Mecham

    2010-10-01

    This conceptual design report addresses development of replacement remote-handled low-level waste disposal capability for the Idaho National Laboratory. Current disposal capability at the Radioactive Waste Management Complex is planned until the facility is full or until it must be closed in preparation for final remediation (approximately at the end of Fiscal Year 2017). This conceptual design report includes key project assumptions; design options considered in development of the proposed onsite disposal facility (the highest ranked alternative for providing continued uninterrupted remote-handled low level waste disposal capability); process and facility descriptions; safety and environmental requirements that would apply to the proposed facility; and the proposed cost and schedule for funding, design, construction, and operation of the proposed onsite disposal facility.

  2. Early Glycemic Control and Magnitude of HbA1c Reduction Predict Cardiovascular Events and Mortality: Population-Based Cohort Study of 24,752 Metformin Initiators.

    Science.gov (United States)

    Svensson, Elisabeth; Baggesen, Lisbeth M; Johnsen, Søren P; Pedersen, Lars; Nørrelund, Helene; Buhl, Esben S; Haase, Christiane L; Thomsen, Reimar W

    2017-06-01

    We investigated the association of early achieved HbA 1c level and magnitude of HbA 1c reduction with subsequent risk of cardiovascular events or death in patients with type 2 diabetes who initiate metformin. This was a population-based cohort study including all metformin initiators with HbA 1c tests in Northern Denmark, 2000-2012. Six months after metformin initiation, we classified patients by HbA 1c achieved (<6.5% or higher) and by magnitude of HbA 1c change from the pretreatment baseline. We used Cox regression to examine subsequent rates of acute myocardial infarction, stroke, or death, controlling for baseline HbA 1c and other confounding factors. We included 24,752 metformin initiators (median age 62.5 years, 55% males) with a median follow-up of 2.6 years. The risk of a combined outcome event gradually increased with rising levels of HbA 1c achieved compared with a target HbA 1c of <6.5%: adjusted hazard ratio (HR) 1.18 (95% CI 1.07-1.30) for 6.5-6.99%, HR 1.23 (1.09-1.40) for 7.0-7.49%, HR 1.34 (1.14-1.57) for 7.5-7.99%, and HR 1.59 (1.37-1.84) for ≥8%. Results were consistent for individual outcome events and robust by age-group and other patient characteristics. A large absolute HbA 1c reduction from baseline also predicted outcome: adjusted HR 0.80 (0.65-0.97) for Δ = -4, HR 0.98 (0.80-1.20) for Δ = -3, HR 0.92 (0.78-1.08) for Δ = -2, and HR 0.99 (0.89-1.10) for Δ = -1 compared with no HbA 1c change (Δ = 0). A large initial HbA 1c reduction and achievement of low HbA 1c levels within 6 months after metformin initiation are associated with a lower risk of cardiovascular events and death in patients with type 2 diabetes. © 2017 by the American Diabetes Association.

  3. Both Autocrine Signaling and Paracrine Signaling of HB-EGF Enhance Ocular Neovascularization.

    Science.gov (United States)

    Inoue, Yuki; Shimazawa, Masamitsu; Nakamura, Shinsuke; Takata, Shinsuke; Hashimoto, Yuhei; Izawa, Hiroshi; Masuda, Tomomi; Tsuruma, Kazuhiro; Sakaue, Tomohisa; Nakayama, Hironao; Higashiyama, Shigeki; Hara, Hideaki

    2018-01-01

    The incidence of blindness is increasing because of the increase in abnormal ocular neovascularization. Anti-VEGF (vascular endothelial growth factor) therapies have led to good results, although they are not a cure for the blindness. The purpose of this study was to determine what role HB-EGF (heparin-binding epidermal growth factor-like growth factor) plays in ocular angiogenesis. We examined the role played by HB-EGF in ocular neovascularization in 2 animal models of neovascularization: laser-induced choroidal neovascularization (CNV) and oxygen-induced retinopathy. We also studied human retinal microvascular endothelial cells in culture. Our results showed that the neovascularization was decreased in both the CNV and oxygen-induced retinopathy models in HB-EGF conditional knockout mice compared with that in wild-type mice. Moreover, the expressions of HB-EGF and VEGF were increased after laser-induced CNV and oxygen-induced retinopathy, and their expression sites were located around the neovascular areas. Exposure of human retinal microvascular endothelial cells to HB-EGF and VEGF increased their proliferation and migration, and CRM-197 (cross-reactive material-197), an HB-EGF inhibitor, decreased the HB-EGF-induced and VEGF-induced cell proliferation and migration. VEGF increased the expression of HB-EGF mRNA. VEGF-dependent activation of EGFR (epidermal growth factor receptor)/ERK1/2 (extracellular signal-regulated kinase 1/2) signaling and cell proliferation of endothelial cells required stimulation of the ADAM17 (a disintegrin and metalloprotease) and ADAM12. CRM-197 decreased the grades of the fluorescein angiograms and size of the CNV areas in marmoset monkeys. These findings suggest that HB-EGF plays an important role in the development of CNV. Therefore, further investigations of HB-EGF are needed as a potential therapeutic target in the treatment of exudative age-related macular degeneration. © 2017 American Heart Association, Inc.

  4. Thermo-aeraulics of high level waste storage facilities

    International Nuclear Information System (INIS)

    Lagrave, Herve; Gaillard, Jean-Philippe; Laurent, Franck; Ranc, Guillaume; Duret, Bernard

    2006-01-01

    This paper discusses the research undertaken in response to axis 3 of the 1991 radioactive waste management act, and possible solutions concerning the processes under consideration for conditioning and long-term interim storage of long-lived radioactive waste. The notion of 'long-term' is evaluated with respect to the usual operating lifetime of a basic nuclear installation, about 50 years. In this context, 'long-term' is defined on a secular time scale: the lifetime of the facility could be as long as 300 years. The waste package taken into account is characterized notably by its high thermal power release. Studies were carried out in dedicated facilities for vitrified waste and for spent UOX and MOX fuel. The latter are not considered as wastes, owing to the value of the reusable material they contain. Three primary objectives have guided the design of these long-term interim storage facilities: - ensure radionuclide containment at all times; - permit retrieval of the containers at any time; - minimize surveillance; - maintenance costs. The CEA has also investigated surface and subsurface facilities. It was decided to work on generic sites with a reasonable set of parameters values that should be applicable at most sites in France. All the studies and demonstrations to date lead to the conclusion that long-term interim storage is technically feasible. The paper addresses the following items: - Long-term interim storage concepts for high-level waste; - Design principles and options for the interim storage facilities; - General architecture; - Research topics, Storage facility ventilation, Dimensioning of the facility; - Thermo-aeraulics of a surface interim storage facility; - VALIDA surface loop, VALIDA single container test campaign, Continuation of the VALIDA program; - Thermo-aeraulics of a network of subsurface interim storage galleries; - SIGAL subsurface loop; - PROMETHEE subsurface loop; - Temperature behaviour of the concrete structures; - GALATEE

  5. Thermo-aeraulics of high level waste storage facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lagrave, Herve; Gaillard, Jean-Philippe; Laurent, Franck; Ranc, Guillaume [CEA/Valrho, B.P. 17171, F-30207 Bagnols-sur-Ceze (France); Duret, Bernard [CEA Grenoble, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France)

    2006-07-01

    This paper discusses the research undertaken in response to axis 3 of the 1991 radioactive waste management act, and possible solutions concerning the processes under consideration for conditioning and long-term interim storage of long-lived radioactive waste. The notion of 'long-term' is evaluated with respect to the usual operating lifetime of a basic nuclear installation, about 50 years. In this context, 'long-term' is defined on a secular time scale: the lifetime of the facility could be as long as 300 years. The waste package taken into account is characterized notably by its high thermal power release. Studies were carried out in dedicated facilities for vitrified waste and for spent UOX and MOX fuel. The latter are not considered as wastes, owing to the value of the reusable material they contain. Three primary objectives have guided the design of these long-term interim storage facilities: - ensure radionuclide containment at all times; - permit retrieval of the containers at any time; - minimize surveillance; - maintenance costs. The CEA has also investigated surface and subsurface facilities. It was decided to work on generic sites with a reasonable set of parameters values that should be applicable at most sites in France. All the studies and demonstrations to date lead to the conclusion that long-term interim storage is technically feasible. The paper addresses the following items: - Long-term interim storage concepts for high-level waste; - Design principles and options for the interim storage facilities; - General architecture; - Research topics, Storage facility ventilation, Dimensioning of the facility; - Thermo-aeraulics of a surface interim storage facility; - VALIDA surface loop, VALIDA single container test campaign, Continuation of the VALIDA program; - Thermo-aeraulics of a network of subsurface interim storage galleries; - SIGAL subsurface loop; - PROMETHEE subsurface loop; - Temperature behaviour of the concrete

  6. Targeting hepatic heparin-binding EGF-like growth factor (HB-EGF) induces anti-hyperlipidemia leading to reduction of angiotensin II-induced aneurysm development.

    Science.gov (United States)

    Kim, Seonwook; Yang, Lihua; Kim, Seongu; Lee, Richard G; Graham, Mark J; Berliner, Judith A; Lusis, Aldons J; Cai, Lei; Temel, Ryan E; Rateri, Debra L; Lee, Sangderk

    2017-01-01

    The upregulated expression of heparin binding EGF-like growth factor (HB-EGF) in the vessel and circulation is associated with risk of cardiovascular disease. In this study, we tested the effects of HB-EGF targeting using HB-EGF-specific antisense oligonucleotide (ASO) on the development of aortic aneurysm in a mouse aneurysm model. Low-density lipoprotein receptor (LDLR) deficient mice (male, 16 weeks of age) were injected with control and HB-EGF ASOs for 10 weeks. To induce aneurysm, the mice were fed a high fat diet (22% fat, 0.2% cholesterol; w/w) at 5 week point of ASO administration and infused with angiotensin II (AngII, 1,000ng/kg/min) for the last 4 weeks of ASO administration. We confirmed that the HB-EGF ASO administration significantly downregulated HB-EGF expression in multiple tissues including the liver. Importantly, the HB-EGF ASO administration significantly suppressed development of aortic aneurysms including thoracic and abdominal types. Interestingly, the HB-EGF ASO administration induced a remarkable anti-hyperlipidemic effect by suppressing very low density lipoprotein (VLDL) level in the blood. Mechanistically, the HB-EGF targeting suppressed hepatic VLDL secretion rate without changing heparin-releasable plasma triglyceride (TG) hydrolytic activity or fecal neutral cholesterol excretion rate. This result suggested that the HB-EGF targeting induced protection against aneurysm development through anti-hyperlipidemic effects. Suppression of hepatic VLDL production process appears to be a key mechanism for the anti-hyperlipidemic effects by the HB-EGF targeting.

  7. A comparison of goniophotometric measurement facilities

    DEFF Research Database (Denmark)

    Thorseth, Anders; Lindén, Johannes; Dam-Hansen, Carsten

    2016-01-01

    In this paper, we present the preliminary results of a comparison between widely different goniophotometric and goniospectroradiometric measurement facilities. The objective of the comparison is to increase consistency and clarify the capabilities among Danish test laboratories. The study will seek...... to find the degree of equivalence between the various facilities and methods. The collected data is compared by using a three-way variation of principal component analysis, which is well suited for modelling large sets of correlated data. This method drastically decreases the number of numerical values...

  8. Peri-conceptional HbA1c and risk of serious adverse pregnancy outcome in 933 women with type 1 diabetes

    DEFF Research Database (Denmark)

    Jensen, Dorte M; Korsholm, Lars; Ovesen, Per

    2009-01-01

    Objectives : To study the association between peri-conceptional HbA1c and serious adverse pregnancy outcome (congenital malformations and perinatal mortality). Methods: Prospective data collection in 933 singleton pregnancies complicated by type 1 diabetes. Results: The risk of serious adverse ou...... malformation rate increased significantly at HbA1c above 10.4% whereas perinatal mortality was increased even at Hba1c below 6.9%. Conclusions: These results support recent guidelines of pre-conceptional HbA1c levels below 7% in women with type 1 diabetes....

  9. New luminescence measurement facilities in retrospective dosimetry

    DEFF Research Database (Denmark)

    Lapp, Torben; Jain, Mayank; Thomsen, Kristina Jørkov

    2012-01-01

    ), this facility has been used to measure natural doses in feldspar using the decaying NIR RL signal.Secondly, we present a method for mapping radiation field of the built-in 90Sr/90Y β-source and estimating grain-location specific dose-rates. This is important for the accuracy of single grain results, when......This paper gives a review of recent developments in luminescence measurement facilities on the Risø TL/OSL reader including radio-luminescence (RL), exo-electron and violet stimulation attachments, and a method for characterising and if necessary correcting for beta irradiation source non...... radiation field is spatially non-uniform across the sample area. We document the effect of this correction method and further investigate on the effect of lifting the source to achieve a better dose-rate uniformity.Finally we summarise two recently-developed novel facilities to help investigate (i) the time...

  10. Siting a low-level waste facility

    International Nuclear Information System (INIS)

    English, M.R.

    1988-01-01

    In processes to site disposal facilities for low-level radioactive waste, volunteerism and incentives packages hold more promise for attracting host communities than they have for attracting host states. But volunteerism and incentives packages can have disadvantages as well as advantages. This paper discusses their pros and cons and summarizes the different approaches that states are using in their relationships with local governments

  11. Glycated albumin is set lower in relation to plasma glucose levels in patients with Cushing's syndrome.

    Science.gov (United States)

    Kitamura, Tetsuhiro; Otsuki, Michio; Tamada, Daisuke; Tabuchi, Yukiko; Mukai, Kosuke; Morita, Shinya; Kasayama, Soji; Shimomura, Iichiro; Koga, Masafumi

    2013-09-23

    Glycated albumin (GA) is an indicator of glycemic control, which has some specific characters in comparison with HbA1c. Since glucocorticoids (GC) promote protein catabolism including serum albumin, GC excess state would influence GA levels. We therefore investigated GA levels in patients with Cushing's syndrome. We studied 16 patients with Cushing's syndrome (8 patients had diabetes mellitus and the remaining 8 patients were non-diabetic). Thirty-two patients with type 2 diabetes mellitus and 32 non-diabetic subjects matched for age, sex and BMI were used as controls. In the patients with Cushing's syndrome, GA was significantly correlated with HbA1c, but the regression line shifted downwards as compared with the controls. The GA/HbA1c ratio in the patients with Cushing's syndrome was also significantly lower than the controls. HbA1c in the non-diabetic patients with Cushing's syndrome was not different from the non-diabetic controls, whereas GA was significantly lower. In 7 patients with Cushing's syndrome who performed self-monitoring of blood glucose, the measured HbA1c was matched with HbA1c estimated from mean blood glucose, whereas the measured GA was significantly lower than the estimated GA. We clarified that GA is set lower in relation to plasma glucose levels in patients with Cushing's syndrome. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Environmental monitoring for low-level radioactive waste-disposal facilities

    International Nuclear Information System (INIS)

    Shum, E.Y.; Starmer, R.J.; Westbrook, K.; Young, M.H.

    1990-01-01

    The U.S. Nuclear Regulatory Commission prepared a Branch Technical Position (BTP) paper on environmental monitoring of a low-level radioactive waste-disposal facility. The BTP provides guidance on what is required in Section 61.53 of 10 CFR Part 61 for those submitting a license application. Guidance is also provided on choosing constituents to measure, setting action levels, relating measurements to appropriate actions in a corrective action plan, and quality assurance. The environmental monitoring program generally consists of three phases: preoperational, operational, and postoperational. Each phase should be designed to fulfill specific objectives defined in the BTP. During the preoperational phase, program objectives are to provide site characterization information, demonstrate site suitability and acceptability, and obtain background or baseline information. Emphasis during the operational phase is on measurement shifts. Monitoring data are obtained to demonstrate compliance with regulations, with dose limits of 10 CFR Part 61, or with applicable U.S. Environmental Protection Agency standards. Data are also used to update important pathway parameters to improve predictions of site performance and to provide a record of performance for public information. The postoperational phase emphasizes measurements to demonstrate compliance with site closure requirements and continued compliance with the performance objective for release. Data are used to support evaluation of long-term impacts to the general public and for public information

  13. The significance of disulfide bonding in biological activity of HB-EGF, a mutagenesis approach

    OpenAIRE

    Hoskins, J.T.; Zhou, Z.; Harding, P.A.

    2008-01-01

    A site-directed mutagenesis approach was taken to disrupt each of 3 disulfide bonds within human HB-EGF by substituting serine for both cysteine residues that contribute to disulfide bonding. Each HB-EGF disulfide analogue (HB-EGF-Cys/Ser108/121, HB-EGF-Cys/Ser116/132, and HB-EGF-Cys/Ser134/143) was cloned under the regulation of the mouse metallothionein (MT) promoter and stably expressed in mouse fibroblasts. HB-EGF immunoreactive proteins with Mr of 6.5, 21 and 24kDa were observed from lys...

  14. Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets.

    Science.gov (United States)

    Lenters-Westra, Erna; English, Emma

    2017-08-28

    As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.

  15. Description of Three New α Variants and Four New β Variants: Hb Montluel [α110(G17)Ala → Val; HBA1: c.332C > T], Hb Cap d'Agde [α131(H14)Ser → Cys; HBA2: c.395C > G] and Hb Corsica [α100(G7)Leu → Pro; HBA1: 302T > C]; Hb Nîmes [β104(G6)Arg → Gly; HBB: c.313A > G], Hb Saint Marcellin [β112(G14)Cys → Gly; HBB: c.337T > G], Hb Saint Chamond [β80(EF4)Asn → 0; HBB: c.241_243delAAC] and Hb Dompierre [β29(B11)Gly → Arg; HBB: c.88G > C].

    Science.gov (United States)

    Renoux, Céline; Feray, Cécile; Joly, Philippe; Lacan, Philippe; Francina, Alain

    2015-01-01

    We present here seven new hemoglobin (Hb) variants identified during routine Hb analysis. All of them are caused by a missense mutation except Hb Saint Chamond, which results from an in-frame deletion of the asparagine residue at β80. All these variants are clinically silent in the heterozygous state but two of them (Hb Cap d'Agde and Hb Dompierre) may be unstable, whereas Hb Nîmes could present a very slightly elevated oxygen affinity. These data are to be confirmed by appropriate biochemical tests.

  16. Directions in low-level radioactive waste management. Low level-radioactive waste disposal: currently operating commercial facilities

    International Nuclear Information System (INIS)

    1983-09-01

    This publication discusses three commercial facilities that receive and dispose of low-level radioactive waste. The facilities are located in Barnwell, South Carolina; Beatty, Nevada; and Richland, Washington. All three facilities initiated operations in the 1960s. The three facilities have operated without such major problems as those which led to the closure of three other commercial disposal facilities located in the United States. The Beatty site could be closed in 1983 as a result of a Nevada Board of Health ruling that renewal of the site license would be inimical to public health and safety. The site remains open pending federal and state court hearings, which began in January 1983, to resolve the Board of Health ruling. The three sites may also be affected by NRC's 10 CFR Part 61 regulations, but the impact of those regulations, issued in December 1982, has not yet been assessed. This document provides detailed information on the history and current status of each facility. This information is intended, primarily, to assist state officials - executive, legislative, and agency - in planning for, establishing, and managing low-level waste disposal facilities. 12 references

  17. Posterior transverse interarch discrepancy on HbE β thalassemia patients

    Directory of Open Access Journals (Sweden)

    Yuniar Zen

    2011-03-01

    Full Text Available Background: One of the symptoms that often arises on thalassemia patients is disharmony dentofacial, class II skeletal malocclusion, as a result of the malrelation of maxilla and mandible. This malrelation can be affected by either maxillary bone position, dentoalveolar maxillary position, mandibular bone position, dentoalveolar mandibular position, or combinations of those components. Purpose: The study was aimed to examine whether there is posterior transverse interarch discrepancy on the HbE β thalassemia patients or not. Methods: This study is an observational research with cross-sectional design. The sample consisted of 33 HbE β thalassemia patients and 33 non-thalassemia patients as a control group aged 12–14 years. Lateral cephalogram was carried out and dental casts of maxillary and mandibular dental arches were also taken in all of those patients. Results: There was no difference between the maxillary intermolar width of the HbE β thalassemia patients and that of the normal ones, but the mandibular intermolar width of the HbE β thalassemia patients was significantly smaller than that of the normal ones. Beside that, posterior transverse interarch discrepancy of of the HbE β thalassemia patients was significantly greater than that of the normal ones, which showed great difference between maxillary and mandibular intermolar widths. Conclusion: Posterior transverse interarch discrepancy of the HbE β thalassemia patients was different from that of the normal ones. The dentofacial abnormalities on the HbE β thalassemia patients aged 12–14 years primarily was due to disporposional dentofacial growth in the vertical, sagittal, and transversal directions, especially in the posterior region.Latar belakang: Salah satu akibat yang sering timbul pada penderita talasemia adalah disharmoni dentofasial berupa maloklusi skeletal kelas II yang merupakan kelainan hubungan maksila dan mandibula. Malrelasi ini dapat dipengaruhi oleh posisi

  18. Nota sobre antígeno relacionado à hepatite (HB Ag e anticorpo (HB Ab em população do território Federal do Amapá

    Directory of Open Access Journals (Sweden)

    Hermann G. Schatzmayr

    1974-04-01

    Full Text Available 53 amostras de soro, provenientes de Ferreira Gomes, no Amapá, foram testados para antígeno HB Ag e anticorpo HB Ab, com uma positividade de 3,7% para HB Ag, sub-tipo D. Os autores acentuam a necessidade de inquéritos em populações brasileiras a fim de estabelecer os sub-tipos associados à hepatite.3,7% of 53 serum samples from healthy inhabitants of Ferreira Gomes, Amapá, were positive for HB Ag, subtype D. The authors síress the needs of surveys to deteet the prevalent types of antigens associated with viral hepatitis in different areas of Brazil.

  19. Performance of HbA1c as an early diagnostic indicator of type 1 diabetes in children and youth.

    Science.gov (United States)

    Vehik, Kendra; Cuthbertson, David; Boulware, David; Beam, Craig A; Rodriguez, Henry; Legault, Laurent; Hyytinen, Mila; Rewers, Marian J; Schatz, Desmond A; Krischer, Jeffrey P

    2012-09-01

    The aim of this study was to evaluate HbA(1c) as an alternative criterion for impaired glucose tolerance (IGT) or type 1 diabetes (T1D) in high-risk subjects TrialNet Natural History (TrialNet) studies and had an HbA(1c) within 90 days of an OGTT with a 2-h plasma glucose (2-hPG) measure were included. An OGTT of 140-199 mg/dL defined IGT, and an OGTT with 2-hPG ≥200 mg/dL or fasting plasma glucose ≥126 mg/dL defined diabetes. HbA(1c) ≥5.7% defined IGT, and HbA(1c) ≥ 6.5% defined diabetes. Receiver-operating characteristic curve analysis was used to assess diagnostic accuracy of HbA(1c) compared with OGTT. There were 587 subjects from DPT-1, 884 from TrialNet, 91 from TEDDY, and 420 from TRIGR. As an indicator for IGT, HbA(1c) sensitivity was very low across the studies (8-42%), and specificity was variable (64-95%). With HbA(1c) ≥6.5% threshold used for T1D diagnosis, the sensitivity was very low and specificity was high (sensitivity and specificity: DPT-1 24 and 98%, TrialNet 28 and 99%, TEDDY 34 and 98%, and TRIGR 33 and 99%, respectively). The positive predictive value of HbA(1c) ≥6.5% for the development of T1D was variable (50-94%) across the four studies. HbA(1c) ≥6.5% is a specific but not sensitive early indicator for T1D in high-risk subjects <21 years of age diagnosed by OGTT or asymptomatic hyperglycemia. Redefining the HbA(1c) threshold is recommended if used as an alternative criterion in diagnosing T1D.

  20. Facility for low-level solid waste treatment

    International Nuclear Information System (INIS)

    Vicente, R.; Miyamoto, H.

    1987-01-01

    A facility for low-level solid waste compaction, encapsulation and storage is described. Solid wastes are compacted in 200 l drums and stored over concrete platforms covered with canvas, for decay or for interim storage before transport to the final disposal site. (Author) [pt

  1. HbA1c, fasting plasma glucose and the prediction of diabetes

    DEFF Research Database (Denmark)

    Soulimane, Soraya; Simon, Dominique; Shaw, Jonathan

    2012-01-01

    With diabetes defined by HbA1c≥6.5% and/or FPG≥7.0mmol/l and/or diabetes treatment, we investigated HbA1c and fasting plasma glucose (FPG) thresholds/change-points above which the incidence of diabetes increases.......With diabetes defined by HbA1c≥6.5% and/or FPG≥7.0mmol/l and/or diabetes treatment, we investigated HbA1c and fasting plasma glucose (FPG) thresholds/change-points above which the incidence of diabetes increases....

  2. Avaliação eletroforética, cromatográfica e molecular da Hb D Los Angeles no Brasil Electrophoretical, chromatographic and molecular valuations of Hb D Los Angeles in Brazil

    Directory of Open Access Journals (Sweden)

    Ana R. Chinelato-Fernandes

    2003-01-01

    Full Text Available A variante de hemoglobina (Hb D mais comum, Hb D Los Angeles ou D Punjab, é originada de uma transversão GAA->CAA no códon 121 da globina beta; essa mutação resulta na substituição do ácido glutâmico por glutamina na proteína. É a terceira variante de hemoglobina mais freqüente da população brasileira. Como as hemoglobinas D apresentam migração similar à hemoglobina S em pH alcalino, e com a hemoglobina A em pH ácido, são necessários vários testes para o correto diagnóstico. No presente estudo objetivou-se relacionar os diferentes procedimentos laboratoriais de rotina diagnóstica, além da análise molecular, para estabelecer o perfil de Hb D Los Angeles no Brasil. Foram analisados 47 indivíduos da população brasileira com provável Hb D Los Angeles, por vários procedimentos eletroforéticos em diferentes condições de pH, além da cromatografia líquida de alta pressão, e testes moleculares para confirmação da mutação. Foram encontrados quatro tipos de combinações de hemoglobinas: 42 indivíduos portadores de hemoglobina AD Los Angeles, dois indivíduos com doença de Hb S/D Los Angeles, dois indivíduos com Hb D Los Angeles e talassemia beta e um indivíduo com Hb D Los Angeles e Hb Lepore. Os indivíduos heterozigotos para D Los Angeles são assintomáticos, entretanto, em associação com outras variantes e talassemias podem apresentar graus variáveis de manifestações clínicas. Os resultados apresentados enfatizaram a necessidade da associação de várias metodologias para a identificação da Hb D Los Angeles, além de auxiliar na elucidação de combinações raras.The most common Hb D variant, the Hb D-Los Angeles, also know as Hb D-Punjab, originates through a GAA->CAA change at the 121 codon of the beta globin gene; this mutation results in the replacement of glutamic acid for glutamine in the protein. It is the third most common hemoglobin variant in the Brazilian population. This variant has

  3. Detailed description of an SSAC at the facility level for mixed oxide fuel fabrication facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-09-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in a mixed oxide fuel fabrication facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  4. Cell model for the study of receptor and regulatory functions of human proHB-EGF

    Directory of Open Access Journals (Sweden)

    N. V. Korotkevych

    2014-08-01

    Full Text Available Developing of new models and approaches, particularly with fluorescent techniques, for investigation of intracellular transport of proHB-EGF and its ligand-receptor complexes is strongly required. In order to create a model for studying proHB-EGF functions the genetic construction pEGFP-N1-proHB-EGF, encoding proHB-EGF-EGFP which is fluorescent-labeled form of proHB-EGF with enhanced green fluorescent protein EGFP in the cytoplasmic terminus of the molecule, was obtained. Eukaryotic cells expressing fusion protein proHB-EGF-EGFP on the cell surface were obtained by transfection with pEGFP-N1-proHB-EGF. Expressed in the Vero cells proHB-EGF-EGFP could bind fluorescent derivative of nontoxic receptor-binding subunit B of diphtheria toxin mCherry-SubB. After stimulation of transfected cells with TPA (12-O-Tetradecanoylphorbol-13-acetate, proHB-EGF-EGFP formed a fluorescentl-labeled C-terminal fragment of the molecule – CTF-EGFP. Thus, the obtained genetic construction pEGFP-N1-proHB-EGF could be helpful in visualization of molecules proHB-EGF and CTF in cells, may open new possibilities for the studying of their functions, such as receptor function of proHB-EGF for diphtheria toxin, intracellular translocation of CTF and provide possibilities for natural proHB-EGF ligands search.

  5. Exploring the ϒ (4 S ,5 S ,6 S )→hb(1 P )η hidden-bottom hadronic transitions

    Science.gov (United States)

    Zhang, Yawei; Li, Gang

    2018-01-01

    Recently, the Belle Collaboration has reported the measurement of the spin-flipping transition ϒ (4 S )→hb(1 P )η with an unexpectedly large branching ratio: B (ϒ (4 S )→hb(1 P )η )=(2.18 ±0.11 ±0.18 )×10-3 . Such a large branching fraction contradicts with the anticipated suppression for the spin flip. In this work, we examine the effects induced by intermediate bottomed meson loops and point out that these effects are significantly important. Using the effective Lagrangian approach (ELA), we find the experimental data on ϒ (4 S )→hb(1 P )η can be accommodated with the reasonable inputs. We then explore the decays ϒ (5 S ,6 S )→hb(1 P )η and find that these two channels also have sizable branching fractions. We also calculate these processes in the framework of nonrelativistic effective field theory (NREFT). For the decays ϒ (4 S )→hb(1 P )η , the NREFT results are at the same order of magnitude but smaller than the ELA results by a factor of 2 to 5. For the decays ϒ (5 S ,6 S )→hb(1 P )η , the NREFT results are smaller than the ELA results by approximately 1 order of magnitude. We suggest a future experiment Belle-II to search for the ϒ (5 S ,6 S )→hb(1 P )η decays, which will be helpful for understanding the transition mechanism.

  6. Change in HbA1c levels between the age of 8 years and the age of 12 years in Dutch children without diabetes : The PIAMA birth cohort study

    NARCIS (Netherlands)

    H. Jansen; A.H. Wijga (Alet); S. Scholtens (Salome); G.H. Koppelman (Gerard); D.S. Postma (Dirkje); B. Brunekreef (Bert); J.C. de Jongste (Johan); H.A. Smit (Henriëtte); R.P. Stolk (Ronald)

    2015-01-01

    textabstractObjective: HbA1c is associated with cardiovascular risk in persons without diabetes and cardiovascular risk accumulates over the life course. Therefore, insight in factors determining HbA1c from childhood onwards is important. We investigated (lifestyle) determinants of HbA1c at age 12

  7. Operation of a low-level waste disposal facility and how to prevent problems in future facilities

    International Nuclear Information System (INIS)

    Di Sibio, R.

    1985-01-01

    Operation of a low-level waste facility is an ever increasing problem nationally, and specifically one that could grow to crisis proportion in Pennsylvania. There have been, nevertheless, a variety of changes over the years in the management of low level radioactive waste, particularly with regard to disposal facilities that can avert a crisis condition. A number of companies have been organized thru possible a broad range of services to the nuclear industry, including those that emphasize solidification of waste materials, engineering services, waste management, and transportation to disposal sites across the United States. This paper addresses one particular site and the problems which evolved at that site from an environmental perspective. It is important that it is clearly understood that, although these problems are resolvable, the lessons learned here are critical for the prevention of problems at future facilities. The focus of this paper is on the Maxey Flats, Kentucky disposal facility which was closed in 1977. It must be understood that the regulations for siting, management, burial techniques, waste classification, and the overall management of disposal sites were limited when this facility was in operation

  8. Change in HbA1c levels between the age of 8 years and the age of 12 years in Dutch children without diabetes : The PIAMA birth cohort study

    NARCIS (Netherlands)

    Jansen, Hanneke; Wijga, Alet H.; Scholtens, Salome; Koppelman, Gerard H.; Postma, Dirkje S.; Brunekreef, Bert; De Jongste, Johan C.; Smit, Henriëtte A.; Stolk, Ronald P.

    2015-01-01

    Objective: HbA1c is associated with cardiovascular risk in persons without diabetes and cardiovascular risk accumulates over the life course. Therefore, insight in factors determining HbA1c from childhood onwards is important. We investigated (lifestyle) determinants of HbA1c at age 12 years and the

  9. Change in HbA1c levels between the age of 8 years and the age of 12 years in Dutch children without diabetes : the PIAMA birth cohort study

    NARCIS (Netherlands)

    Jansen, Hanneke; Wijga, Alet H; Scholtens, Salome|info:eu-repo/dai/nl/304834548; Koppelman, Gerard H; Postma, Dirkje S; Brunekreef, Bert|info:eu-repo/dai/nl/067548180; de Jongste, Johan C; Smit, Henriëtte A; Stolk, Ronald P

    2015-01-01

    OBJECTIVE: HbA1c is associated with cardiovascular risk in persons without diabetes and cardiovascular risk accumulates over the life course. Therefore, insight in factors determining HbA1c from childhood onwards is important. We investigated (lifestyle) determinants of HbA1c at age 12 years and the

  10. Change in HbA1c Levels between the Age of 8 Years and the Age of 12 Years in Dutch Children without Diabetes : The PIAMA Birth Cohort Study

    NARCIS (Netherlands)

    Jansen, Hanneke; Wijga, Alet H.; Scholtens, Salome; Koppelman, Gerard H.; Postma, Dirkje S.; Brunekreef, Bert; de Jongste, Johan C.; Smit, Henriette A.; Stolk, Ronald P.

    2015-01-01

    Objective HbA1c is associated with cardiovascular risk in persons without diabetes and cardiovascular risk accumulates over the life course. Therefore, insight in factors determining HbA1c from childhood onwards is important. We investigated (lifestyle) determinants of HbA1c at age 12 years and the

  11. The Natural History of Hb S/Hereditary Persistence of Fetal Hemoglobin in 13 Children from the State of Minas Gerais, Brazil.

    Science.gov (United States)

    Belisário, André R; Sales, Rahyssa R; Silva, Célia M; Velloso-Rodrigues, Cibele; Viana, Marcos Borato

    2016-06-01

    Children with Hb S (HBB: c.20A > T)/hereditary persistence of fetal hemoglobin (Hb S/HPFH) have a mild clinical phenotype, but some complications have been reported. The natural history of Hb S/HPFH in children from the State of Minas Gerais, Brazil newborn cohort is described. Clinical and hematological data regarding participants' phenotypes were retrieved from medical records. The HPFH-1, HPFH-2, and HPFH-3 and α-thalassemia (α-thal) deletions were detected by gap-polymerase chain reaction (gap-PCR). Thirteen children were included, nine (69.2%) had the Hb S/HPFH-2 deletion, and four (30.8%) had Hb S/HPFH-1 deletion; 11 children (84.6%) had αα/αα, and two (15.4%) carried the αα/-α(3.7) (rightward) deletion. The mean concentration of total hemoglobin (Hb) and Hb F was 12.52 ± 0.56 g/dL and 42.31% ± 1.97%, respectively. Mild microcytosis and hypochromia were observed. We found acute clinical manifestations of sickle cell disease, such as acute chest syndrome (ACS) and acute pain crisis in four children; nine (69.2%) children were completely asymptomatic during the follow-up period. All children were classified as having low-risk transcranial Doppler (TDC). In conclusion, children with Hb S/HPFH have a mild clinical phenotype of sickle cell disease, although acute clinical manifestations may occur. High Hb F levels and absence of anemia are common hematological characteristics.

  12. HbA1c as a Predictor of Diabetes and as an Outcome in the Diabetes Prevention Program: A Randomized Clinical Trial

    Science.gov (United States)

    2015-01-01

    OBJECTIVE Glycated hemoglobin (HbA1c), a standard measure of chronic glycemia for managing diabetes, has been proposed to diagnose diabetes and identify people at risk. The Diabetes Prevention Program (DPP) was a 3.2-year randomized clinical trial of preventing type 2 diabetes with a 10-year follow-up study, the DPP Outcomes Study (DPPOS). We evaluated baseline HbA1c as a predictor of diabetes and determined the effects of treatments on diabetes defined by an HbA1c ≥6.5% (48 mmol/mol). RESEARCH DESIGN AND METHODS We randomized 3,234 nondiabetic adults at high risk of diabetes to placebo, metformin, or intensive lifestyle intervention and followed them for the development of diabetes as diagnosed by fasting plasma glucose (FPG) and 2-h postload glucose (2hPG) concentrations (1997 American Diabetes Association [ADA] criteria). HbA1c was measured but not used for study eligibility or outcomes. We now evaluate treatment effects in the 2,765 participants who did not have diabetes at baseline according to FPG, 2hPG, or HbA1c (2010 ADA criteria). RESULTS Baseline HbA1c predicted incident diabetes in all treatment groups. Diabetes incidence defined by HbA1c ≥6.5% was reduced by 44% by metformin and 49% by lifestyle during the DPP and by 38% by metformin and 29% by lifestyle throughout follow-up. Unlike the primary DPP and DPPOS findings based on glucose criteria, metformin and lifestyle were similarly effective in preventing diabetes defined by HbA1c. CONCLUSIONS HbA1c predicted incident diabetes. In contrast to the superiority of the lifestyle intervention on glucose-defined diabetes, metformin and lifestyle interventions had similar effects in preventing HbA1c-defined diabetes. The long-term implications for other health outcomes remain to be determined. PMID:25336746

  13. HbA1c, diabetes and cognitive decline: the English Longitudinal Study of Ageing.

    Science.gov (United States)

    Zheng, Fanfan; Yan, Li; Yang, Zhenchun; Zhong, Baoliang; Xie, Wuxiang

    2018-04-01

    The aim of the study was to evaluate longitudinal associations between HbA 1c levels, diabetes status and subsequent cognitive decline over a 10 year follow-up period. Data from wave 2 (2004-2005) to wave 7 (2014-2015) of the English Longitudinal Study of Ageing (ELSA) were analysed. Cognitive function was assessed at baseline (wave 2) and reassessed every 2 years at waves 3-7. Linear mixed models were used to evaluate longitudinal associations. The study comprised 5189 participants (55.1% women, mean age 65.6 ± 9.4 years) with baseline HbA 1c levels ranging from 15.9 to 126.3 mmol/mol (3.6-13.7%). The mean follow-up duration was 8.1 ± 2.8 years and the mean number of cognitive assessments was 4.9 ± 1.5. A 1 mmol/mol increment in HbA 1c was significantly associated with an increased rate of decline in global cognitive z scores (-0.0009 SD/year, 95% CI -0.0014, -0.0003), memory z scores (-0.0005 SD/year, 95% CI -0.0009, -0.0001) and executive function z scores (-0.0008 SD/year, 95% CI -0.0013, -0.0004) after adjustment for baseline age, sex, total cholesterol, HDL-cholesterol, triacylglycerol, high-sensitivity C-reactive protein, BMI, education, marital status, depressive symptoms, current smoking, alcohol consumption, hypertension, CHD, stroke, chronic lung disease and cancer. Compared with participants with normoglycaemia, the multivariable-adjusted rate of global cognitive decline associated with prediabetes and diabetes was increased by -0.012 SD/year (95% CI -0.022, -0.002) and -0.031 SD/year (95% CI -0.046, -0.015), respectively (p for trend cognitive decline with diabetes. Significant longitudinal associations between HbA 1c levels, diabetes status and long-term cognitive decline were observed in this study. Future studies are required to determine the effects of maintaining optimal glucose control on the rate of cognitive decline in people with diabetes.

  14. Measuring Inpatient Rehabilitation Facility Quality of Care: Discharge Self-Care Functional Status Quality Measure.

    Science.gov (United States)

    Pardasaney, Poonam K; Deutsch, Anne; Iriondo-Perez, Jeniffer; Ingber, Melvin J; McMullen, Tara

    2018-06-01

    To describe the calculation and psychometric properties of the discharge self-care functional status quality measure implemented in the Centers for Medicare & Medicaid Services' (CMS) Inpatient Rehabilitation Facility (IRF) Quality Reporting Program on October 1, 2016. Medicare fee-for-service (FFS) patients from 38 IRFs that participated in the CMS Post-Acute Care Payment Reform Demonstration were included in this cohort study. Data came from the Continuity Assessment Record and Evaluation Item Set, IRF-Patient Assessment Instrument, and Medicare claims. For each patient, we calculated an expected discharge self-care score, risk-adjusted for demographic and baseline clinical characteristics. The performance score of each IRF equaled the percentage of patient stays where the observed discharge self-care score met or exceeded the expected score. We assessed the measure's discriminatory ability across IRFs and reliability. IRFs. Medicare FFS patients aged ≥21 years (N=4769). Not applicable. Facility-level discharge self-care quality measure performance score. A total of 4769 patient stays were included; 57% of stays were in women, and 12.1% were in patients aged quality measure showed strong reliability, with intraclass correlation coefficients of .91. The discharge self-care quality measure showed strong discriminatory ability and reliability, representing an important initial step in evaluation of IRF self-care outcomes. A wide range in performance scores suggested a gap in quality of care across IRFs. Future work should include testing the measure with nationwide data from all IRFs. Published by Elsevier Inc.

  15. Analysis of HbA1c on an automated multicapillary zone electrophoresis system.

    Science.gov (United States)

    Rollborn, Niclas; Åkerfeldt, Torbjörn; Nordin, Gunnar; Xu, Xiao Yan; Mandic-Havelka, Aleksandra; Hansson, Lars-Olof; Larsson, Anders

    2017-02-01

    Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R 2  = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R 2  = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.

  16. Development of safeguards information treatment system at facility level in Korea

    International Nuclear Information System (INIS)

    So, D.S.; Lee, B.D.; Song, D.Y.

    2001-01-01

    Safeguards Information Treatment System (SITS) at Facility level was developed to implement efficiently the obligations under IAEA comprehensive Safeguards Agreement, bilateral nuclear cooperation Agreements with other countries and domestic law, and to manage efficiently the information related to safeguards implementation at facility level in Korea. Nuclear facilities in Korea are categorized into 8 types based on its accounting characteristics as follows: (1) Item counting facility or bulk handling facility; (2) Batch follow-up facility or not; (3) MUF (Material Unaccounted For) occurrence or not; (4) Nuclear production facility or not; (5) Operation status of facility; (6) Information management of nuclear material transfer status between KMPs or not; (7) Indication of inventory KMP on the inventory change of nuclear material is required or not. Hardware and Software for SITS can be loaded on a personal computer under operation system of Window 2000 or Window NT. MS SQL server 7 and MS Internet Information Server were adopted for database management system and Web server, respectively. Network environment of SITS was designed to include nuclear research institute, nuclear power plants of PWR and CANDU, nuclear fuel fabrication facilities and other facilities. SITS can be operated standalone or under the client-server system if intranet exists. More detailed contents of SITS are described elsewhere. Each module of SITS will be tested during incorporation of existing data into SITS and SITS will be distributed to nuclear facilities in Korea

  17. Study on the relationship between blood levels of glycated hemoglobin (HbA1c) and micro-vascular nephropathy in patients with type 2 diabetes

    International Nuclear Information System (INIS)

    Luo Rong; Li Zhuocheng; Yan Dewen

    2004-01-01

    Objective: To evaluate the relationship between blood levels of glycated hemoglobin and microvascular nephropathy in patients with type diabetes. Methods: Blood Glycosylated hemoglobin levels were determined with affinity chromatography and 24 hour urinary microalbumin (m-Alb), β 2 microglobin (β 2 -m) quantified with RIA in 76 patients and 30 controls. Results: With glycated hemoglobin within normal range, there were no differences between the amounts of patients' urinary protein contents and those in controls (P>0.05). With higher blood glycated hemoglobin levels, significant differences could be observed (P 2 microglobin. Differences among the 24 hour urinary quantities of mAlb and β 2 -m in the three groups of patients (divided according to the HbA1c levels, namely 9.0%) were also significant (P 2 microglobin is very important for early detection of diabetic nephropathy

  18. Mixed and Low-Level Waste Treatment Facility Project

    International Nuclear Information System (INIS)

    1992-04-01

    Mixed and low-level wastes generated at the Idaho National Engineering Laboratory (INEL) are required to be managed according to applicable State and Federal regulations, and Department of Energy Orders that provide for the protection of human health and the environment. The Mixed and Low-Level Waste Treatment Facility Project was chartered in 1991, by the Department of Energy to provide treatment capability for these mixed and low-level waste streams. The first project task consisted of conducting engineering studies to identify the waste streams, their potential treatment strategies, and the requirements that would be imposed on the waste streams and the facilities used to process them. This report documents those studies so the project can continue with an evaluation of programmatic options, system tradeoff studies, and the conceptual design phase of the project. This report, appendix B, comprises the engineering design files for this project study. The engineering design files document each waste steam, its characteristics, and identified treatment strategies

  19. Can HbA1c be Used to Screen for Glucose Abnormalities Among Adults with Severe Mental Illness?

    Science.gov (United States)

    Romain, A J; Letendre, E; Akrass, Z; Avignon, A; Karelis, A D; Sultan, A; Abdel-Baki, A

    2017-04-01

    Aim: Prediabetes and type 2 diabetes are highly prevalent among individuals with serious mental illness and increased by antipsychotic medication. Although widely recommended, many obstacles prevent these patients from obtaining a proper screening for dysglycemia. Currently, glycated hemoglobin (HbA1c), fasting glucose, and 2-hour glucose levels from the oral glucose tolerance test are used for screening prediabetes and type 2 diabetes. The objective of this study was to investigate if HbA1c could be used as the only screening test among individuals with serious mental illness. Methods: Cross sectional study comparing the sensitivity of HbA1c, fasting glucose, and 2-h oral glucose tolerance test to detect dysglycemias in serious mental illness participants referred for metabolic complications. Results: A total of 84 participants (43 female; aged: 38.5±12.8 years; BMI: 35.0±6.8 kg/m²) was included. Regarding prediabetes, 44, 44 and 76% were identified by HbA1c, fasting glucose, and 2 h- oral glucose tolerance test respectively and for type 2 diabetes, 60, 53 and 66% were identified by HbA1c, fasting glucose and 2 h-oral glucose tolerance test. The overlap between the 3 markers was low (8% of participants for prediabetes and 26% for Type 2 diabetes). Sensitivity of HbA1c were moderate (range 40-62.5%), while its specificity was excellent (92-93%). Conclusion: The present study indicates a low agreement between HbA1c, fasting glucose and 2-h oral glucose tolerance test. It appears that these markers do not identify the same participants. Thus, HbA1c may not be used alone to detect all glucose abnormalities among individuals with serious mental illness. © Georg Thieme Verlag KG Stuttgart · New York.

  20. HbA1c below 7% as the goal of glucose control fails to maximize the cardiovascular benefits: a meta-analysis.

    Science.gov (United States)

    Wang, Pin; Huang, Rong; Lu, Sen; Xia, Wenqing; Sun, Haixia; Sun, Jie; Cai, Rongrong; Wang, Shaohua

    2015-09-22

    Whether lowering glycosylated haemoglobin (HbA1c) level below 7.0% improves macro-vascular outcomes in diabetes remains unclear. Here, we aimed to assess the effect of relatively tight glucose control resulting in a follow-up HbA1c level of less or more than 7.0% on cardiovascular outcomes in diabetic patients. We systematically searched Medline, Web of science and Cochrane Library for prospective randomized controlled trials published between Jan 1, 1996 and July 1, 2015 that recorded cardiovascular outcome trials of glucose-lowering drugs or strategies in patients with type 2 diabetes mellitus. Data from 15 studies involving 88,266 diabetic patients with 4142 events of non-fatal myocardial infarction, 6997 of major cardiovascular events, 3517 of heart failure, 6849 of all-cause mortality, 2084 of non-fatal stroke, 3816 of cardiovascular death were included. A 7% reduction of major cardiovascular events was observed only when relatively tight glucose control resulted in a follow-up HbA1c level above 7.0% (OR 0.93, 95% CI 0.88-0.98; I(2) = 33%), however, the patients can benefit from reduction incidence of non-fatal myocardial infarction only when the follow-up HbA1c value below 7.0% (OR 0.85, 95% CI 0.74-0.96). Apart from the HbA1c value above 7.0% (OR 1.22, 95% CI 1.06-1.40), the application of thiazolidinediones (OR 1.39, 95% CI 1.14-1.69) also increased the risk of heart failure, while the gliptins shows neutral effects to heart failure (OR 1.14, 95% CI 0.97-1.34). Relatively tight glucose control has some cardiovascular benefits. HbA1c below 7.0% as the goal to maximize the cardiovascular benefits remains suspended.

  1. Operating instructions for LBL radon measurement facilities

    International Nuclear Information System (INIS)

    Ingersoll, J.G.

    1980-06-01

    This manual is intended for users of the radon-measuring facilities of the Radon Project of the Building Ventilation and Indoor Air Quality Program at Lawrence Berkeley Laboratory. The manual comprises three parts. Part 1 sets out the steps involved in collecting, transferring, and counting radon. Part 2 describes the calibration of the transfer system and of the Lucas cells in the counting system. Part 3 outlines the maintenance procedures for the facility

  2. Materials and degradation modes in an alternative LLW [low-level waste] disposal facility

    International Nuclear Information System (INIS)

    Cowgill, M.G.; MacKenzie, D.R.

    1989-01-01

    The materials used in the construction of alternative low-level waste disposal facilities will be subject to interaction with both the internal and the external environments associated with the facilities and unless precautions are taken, may degrade, leading to structural failure. This paper reviews the characteristics of both environments with respect to three alternative disposal concepts, then assesses how reaction with them might affect the properties of the materials, which include concrete, steel-reinforced concrete, structural steel, and various protective coatings and membranes. It identifies and evaluates the probability of reactions occurring which might lead to degradation of the materials and so compromise the structure. The probability of failure (interpreted relative to the ability of the structure to restrict ingress and egress of water) is assessed for each material and precautionary measures, intended to maximize the durability of the facility, are reviewed. 19 refs., 2 tabs

  3. Developing operating procedures for a low-level radioactive waste disposal facility

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, A.A.; Miner, G.L.; Grahn, K.F.; Pollard, C.G. [Rogers and Associates Engineering Corp., Salt Lake City, UT (United States)

    1993-10-01

    This document is intended to assist persons who are developing operating and emergency procedures for a low-level radioactive waste disposal facility. It provides 25 procedures that are considered to be relatively independent of the characteristics of a disposal facility site, the facility design, and operations at the facility. These generic procedures should form a good starting point for final procedures on their subjects for the disposal facility. In addition, this document provides 55 annotated outlines of other procedures that are common to disposal facilities. The annotated outlines are meant as checklists to assist the developer of new procedures.

  4. Developing operating procedures for a low-level radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Sutherland, A.A.; Miner, G.L.; Grahn, K.F.; Pollard, C.G.

    1993-10-01

    This document is intended to assist persons who are developing operating and emergency procedures for a low-level radioactive waste disposal facility. It provides 25 procedures that are considered to be relatively independent of the characteristics of a disposal facility site, the facility design, and operations at the facility. These generic procedures should form a good starting point for final procedures on their subjects for the disposal facility. In addition, this document provides 55 annotated outlines of other procedures that are common to disposal facilities. The annotated outlines are meant as checklists to assist the developer of new procedures

  5. Use of compensation and incentives in siting low-level radioactive waste disposal facilities

    International Nuclear Information System (INIS)

    1985-04-01

    This report assumes that local opposition is a critical issue in siting low-level radioactive waste disposal facilities. Although it recognizes the importance of local health and safety concerns, this report only addresses the economic issues facing local officials in the siting process. Finding ways to overcome local opposition through economic compensation and incentives is a basic step in the waste facility siting process. The report argues that the use of these compensation and incentive mechanisms can help achieve greater local acceptance of waste facilities and also help ease the economic burdens that many communities bear when they agree to host a low-level waste disposal facility. The growing national need for low-level radioactive waste disposal facilities requires that state and local planning agencies develop creative new procedures for siting facilities, procedures that are sensitive to local perceptions and effects

  6. Licensing procedures for Low-Level Waste disposal facilities

    International Nuclear Information System (INIS)

    Roop, R.D.; Van Dyke, J.W.

    1985-09-01

    This report describes the procedures applicable to siting and licensing of disposal facilities for low-level radioactive wastes. Primary emphasis is placed on those procedures which are required by regulations, but to the extent possible, non-mandatory activities which will facilitate siting and licensing are also considered. The report provides an overview of how the procedural and technical requirements for a low-level waste (LLW) disposal facility (as defined by the Nuclear Regulatory Commission's Rules 10 CFR Parts 2, 51, and 61) may be integrated with activities to reduce and resolve conflict generated by the proposed siting of a facility. General procedures are described for site screening and selection, site characterization, site evaluation, and preparation of the license application; specific procedures for several individual states are discussed. The report also examines the steps involved in the formal licensing process, including docketing and initial processing, preparation of an environmental impact statement, technical review, hearings, and decisions. It is concluded that development of effective communication between parties in conflict and the utilization of techniques to manage and resolve conflicts represent perhaps the most significant challenge for the people involved in LLW disposal in the next decade. 18 refs., 6 figs

  7. Low Hemoglobin among Pregnant Women in Midwives Practice of Primary Health Care, Jatinangor, Indonesia: Iron Deficiency Anemia or β-Thalassemia Trait?

    Science.gov (United States)

    Susanti, Ari Indra; Winarno, Gatot; Sugianli, Adhi Kristianto; Susanto, Herman; Panigoro, Ramdan

    2017-01-01

    Low hemoglobin (Hb) or anemia is common among pregnant women in developing countries which may cause adverse pregnancy outcomes and maternal deaths. Our study aimed to assess Hb level measured by midwives in primary health care facility at rural area of Jatinangor, Indonesia, and to explore whether the anemia was due to iron deficiency (IDA) or β-thalassemia trait (β-TT). Pregnant women (n = 105) had finger prick test for Hb level during a regular antenatal care examination from October to November 2016. Hb level by finger prick test was compared with venous blood, measured by complete blood count (CBC). Indices including MCV and MCH and indices of Shine & Lal, Mentzer, Srivastava, Engels & Frase, Ehsani, and Sirdah were analyzed to differentiate anemia due to IDA and anemia due to suspect β-TT. HbA2 was measured to confirm β-TT. Anemic pregnant women were found in 86.7% by finger prick test compared to 21.9% (n = 23) by CBC. The prevalence of β-TT in our study was 5.7%. Hb measurement among pregnant women in low resource area is highly important; however, finger prick test in this study showed a high frequency of anemia which may lead to iron oversupplementation. A standard CBC is encouraged; MCV and MCH would help midwives to identify β-TT. PMID:28634546

  8. HbA1c as a Screening tool for Ketosis in Patients with Type 2 Diabetes Mellitus

    Science.gov (United States)

    Zhu, Bing; Bu, Le; Zhang, Manna; Gusdon, Aaron M.; Zheng, Liang; Rampersad, Sharvan; Li, Jue; Qu, Shen

    2016-01-01

    Ketosis in patients with type 2 diabetes mellitus (T2DM) is overlooked due to atypical symptoms. The objective of this study is to evaluate the value of hemoglobin A1c (HbA1c) as a screening tool for ketosis in T2DM patients. This retrospective study consisted of 253 T2DM patients with ketosis at Shanghai 10th People’s Hospital during a period from January 1, 2011 to June 30, 2015. A control group consisted of 221 T2DM patients without ketosis randomly selected from inpatients during the same period. Receiver operating characteristic curve (ROC) analysis was used to examine the sensitivity and specificity of HbA1c as an indicator for ketosis. Higher HbA1c levels were correlated with ketosis. In patients with newly diagnosed T2DM, the area under the curve (AUC) was 0.832, with 95% confidence interval (CI) 0.754–0.911. The optimal threshold was 10.1% (87 mmol/mol). In patients with previously diagnosed T2DM, the AUC was 0.811 (95% CI: 0.767–0.856), with an optimal threshold of 8.6% (70 mmol/mol). HbA1c is a potential screening tool for ketosis in patients with T2DM. Ketosis is much more likely with HbA1c values at ≥10.1% in patients with newly diagnosed T2DM and HbA1c values at ≥8.6% in patients with previously diagnosed T2DM. PMID:28009017

  9. Associations of HbA1c and fasting plasma glucose with incident diabetes: Implications for pre-diabetes thresholds in a Japanese population.

    Science.gov (United States)

    Nakagami, Tomoko; Tanaka, Yuki; Oya, Junko; Kurita, Moritoshi; Isago, Chisato; Hasegawa, Yukiko; Ito, Arata; Hirota, Naoki; Tsuzura, Reika; Uchigata, Yasuko

    2016-12-01

    This study assessed pre-diabetes (pre-DM) cutoffs for HbA1c and fasting plasma glucose (FPG) that were associated with an increased risk of incident DM. We evaluated 2267 non-diabetic Japanese health-check examinees (HbA1c: HbA1c of ≥6.5% (≥48mmol/mol), FPG of ≥7.0mmol/L, or physician-diagnosed DM. During 11047 person-years, we identified 99 incident DM cases (4.3%). The incidence of DM increased with increasing baseline HbA1c or FPG levels, and the change points (95% confidence intervals) were 5.7% (5.6-5.7%; 39mmol/mol [38-39mmol/mol]) for HbA1c and 5.5mmol/L (5.5-5.6mmol/L) for FPG. The adjusted hazard ratios (HRs) for incident DM per one standard deviation-increase in HbA1c and FPG were 5.5 (4.4-6.8) and 4.0 (3.2-4.8), respectively. The adjusted HRs for incident DM were significantly higher at HbA1c of 5.7-6.4% (39-46mmol/mol) or FPG of 5.5-6.9mmol/L, compared to HbA1c of HbA1c and 5.5mmol/L for FPG in this Japanese population. Copyright © 2016 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  10. Reactions of nitrite with hemoglobin measured by membrane inlet mass spectrometry

    Science.gov (United States)

    Tu, Chingkuang; Mikulski, Rose; Swenson, Erik R.; Silverman, David N.

    2010-01-01

    Membrane inlet mass spectrometry was used to observe nitric oxide in the well-studied reaction of nitrite with hemoglobin. The membrane inlet was submerged in the reaction solutions and measured NO in solution via its flux across a semipermeable membrane leading to the mass spectrometer detecting the mass-to-charge ratio m/z 30. This method measures NO directly in solution and is an alternate approach compared with methods that purge solutions to measure NO. Addition to deoxy-Hb(FeII) (near 38 µM heme concentration) of nitrite in a range of 80 µM to 16 mM showed no accumulation of either NO or N2O3 on a physiologically relevant time scale with a sensitivity near 1 nM. The addition of nitrite to oxy-Hb(FeII) and met-Hb(FeIII) did not accumulate free NO to appreciable extents. These observations show that for several minutes after mixing nitrite with hemoglogin, free NO does not accumulate to levels exceeding the equilibrium level of NO. The presence of cyanide ions did not alter the appearance of the data; however, the presence of 2 mM mercuric ions at the beginning of the experiment with deoxy-Hb(FeII) shortened the initial phase of NO accumulation and increased the maximal level of free, unbound NO by about twofold. These experiments appear consistent with no role of met-Hb(FeIII) in the generation of NO and an increase in nitrite reductase activity caused by the presumed binding of mercuric to cysteine residues. These results raise questions about the ability of reduction of nitrite mediated by deoxy-Hb(FeII) to play a role in vasodilation. PMID:18848984

  11. Measurement Capabilities of the DOE ARM Aerial Facility

    Science.gov (United States)

    Schmid, B.; Tomlinson, J. M.; Hubbe, J.; Comstock, J. M.; Kluzek, C. D.; Chand, D.; Pekour, M. S.

    2012-12-01

    The Department of Energy Atmospheric Radiation Measurement (ARM) Program is a climate research user facility operating stationary ground sites in three important climatic regimes that provide long-term measurements of climate relevant properties. ARM also operates mobile ground- and ship-based facilities to conduct shorter field campaigns (6-12 months) to investigate understudied climate regimes around the globe. Finally, airborne observations by ARM's Aerial Facility (AAF) enhance the surface-based ARM measurements by providing high-resolution in situ measurements for process understanding, retrieval algorithm development, and model evaluation that is not possible using ground-based techniques. AAF started out in 2007 as a "virtual hangar" with no dedicated aircraft and only a small number of instruments owned by ARM. In this mode, AAF successfully carried out several missions contracting with organizations and investigators who provided their research aircraft and instrumentation. In 2009, the Battelle owned G-1 aircraft was included in the ARM facility. The G-1 is a large twin turboprop aircraft, capable of measurements up to altitudes of 7.5 km and a range of 2,800 kilometers. Furthermore the American Recovery and Reinvestment Act of 2009 provided funding for the procurement of seventeen new instruments to be used aboard the G-1 and other AAF virtual-hangar aircraft. AAF now executes missions in the virtual- and real-hangar mode producing freely available datasets for studying aerosol, cloud, and radiative processes in the atmosphere. AAF is also heavily engaged in the maturation and testing of newly developed airborne sensors to help foster the next generation of airborne instruments. In the presentation we will showcase science applications based on measurements from recent field campaigns such as CARES, CALWATER and TCAP.

  12. How can point-of-care HbA1c testing be integrated into UK primary care consultations? - A feasibility study.

    Science.gov (United States)

    Hirst, J A; Stevens, R J; Smith, I; James, T; Gudgin, B C; Farmer, A J

    2017-08-01

    Point-of-care (POC) HbA1c testing gives a rapid result, allowing testing and treatment decisions to take place in a single appointment. Trials of POC testing have not been shown to improve HbA1c, possibly because of how testing was implemented. This study aimed to identify key components of POC HbA1c testing and determine strategies to optimise implementation in UK primary care. This cohort feasibility study recruited thirty patients with type 2 diabetes and HbA1c>7.5% (58mmol/mol) into three primary care clinics. Patients' clinical care included two POC HbA1c tests over six months. Data were collected on appointment duration, clinical decisions, technical performance and patient behaviour. Fifty-three POC HbA1c consultations took place during the study; clinical decisions were made in 30 consultations. Five POC consultations with a family doctor lasted on average 11min and 48 consultations with nurses took on average 24min. Five POC study visits did not take place in one clinic. POC results were uploaded to hospital records from two clinics. In total, sixty-three POC tests were performed, and there were 11 cartridge failures. No changes in HbA1c or patient behaviour were observed. HbA1c measurement with POC devices can be effectively implemented in primary care. This work has identified when these technologies might work best, as well as potential challenges. The findings can be used to inform the design of a pragmatic trial to implement POC HbA1c testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Atmospheric Radiation Measurement Program facilities newsletter, January 2001.; TOPICAL

    International Nuclear Information System (INIS)

    Holdridge, D. J.

    2001-01-01

    In the realm of global climate modeling, numerous variables affect the state of the atmosphere and climate. One important area is soil moisture and temperature. The ARM Program uses several types of instruments to gather soil moisture information. An example is the soil water and temperature system (SWATS). A SWATS is located at each of 21 extended facility sites within the CART site boundary. Each system is configured to measure soil moisture and temperature at eight distinct subsurface levels. A special set of probes used in the SWATS measures soil temperature, soil-water potential, and volumetric water content. Sensors are placed at eight different depths below the soil surface, starting at approximately 5 cm (2 in.) below the surface and ending as deep as 175 cm (69 in.). Each site has two identical sets of probes buried 1 m (3.3 ft) apart, to yield duplicate measurements as a quality control measure. At some sites, impenetrable soil or rock layers prevented installation of probes at the deeper levels. The sensors are connected to an electronic data logger that collects and stores the data. Communication equipment transfers data from the site. All of the electronic equipment is housed in a weatherproof enclosure mounted on a concrete slab

  14. Neutron cross-section measurements at the nTOF facility at CERN

    CERN Document Server

    Colonna, N

    2004-01-01

    A neutron Time-of-Flight facility (n_TOF) has recently become operative at CERN. The innovative features of the neutron beam, in particular the high instantaneous flux, the wide energy range, the high resolution and the low background, make this facility unique for measurements of neutron-induced reactions relevant to the field of emerging nuclear technologies, as well as to Nuclear Astrophysics and fundamental Nuclear Physics. The n_TOF facility is here described, together with the main features of the experimental apparata used for cross-section measurements. The results of the first measurement campaign, which have confirmed the innovative aspects of the facility, are presented. The measurement plan of the n_TOF collaboration, in particular with regard to implications to ADS, is briefly discussed.

  15. HB+ prepares for insertion into the CMS solenoid

    CERN Multimedia

    Dave Barney, CERN

    2006-01-01

    With calibration of the first half of the barrel Hadron Calorimeter (HB+) complete (using a radioactive source), preparations begin for its insertion into the solenoid for the Magnet Test and Cosmic Challenge (MTCC). It was moved out of its alcove at the beginning of March - a non-trivial (but completely successful) operation due to the proximity of one of the barrel yoke rings (YB+1). The other half of the barrel Hadron Calorimeter (HB-) and one of the endcaps (HE+) should also be calibrated before the MTCC.

  16. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  17. Induction of anti-HBs in HB vaccine nonresponders in vivo by hepatitis B surface antigen-pulsed blood dendritic cells.

    Science.gov (United States)

    Fazle Akbar, Sk Md; Furukawa, Shinya; Yoshida, Osamu; Hiasa, Yoichi; Horiike, Norio; Onji, Morikazu

    2007-07-01

    Antigen-pulsed dendritic cells (DCs) are now used for treatment of patients with cancers, however, the efficacy of these DCs has never been evaluated for prophylactic purposes. The aim of this study was (1) to prepare hepatitis B surface antigen (HBsAg)-pulsed human blood DCs, (2) to assess immunogenicity of HBsAg-pulsed DCs in vitro and (3) to evaluate the efficacy of HBsAg-pulsed DCs in hepatitis B (HB) vaccine nonresponders. Human peripheral blood DCs were cultured with HBsAg to prepare HBsAg-pulsed DCs. The expression of immunogenic epitopes of HBsAg on HBsAg-pulsed DCs was assessed in vitro. Finally, HBsAg-pulsed DCs were administered, intradermally to six HB vaccine nonresponders and the levels of antibody to HBsAg (anti-HBs) in the sera were assessed. HB vaccine nonresponders did not exhibit features of immediate, early or delayed adverse reactions due to administration of HBsAg-pulsed DCs. Anti-HBs were detected in the sera of all HB vaccine nonresponders within 28 days after administration of HBsAg-pulsed DCs. This study opens a new field of application of antigen-pulsed DCs for prophylactic purposes when adequate levels of protective antibody cannot be induced by traditional vaccination approaches.

  18. Parsimonious model for blood glucose level monitoring in type 2 diabetes patients.

    Science.gov (United States)

    Zhao, Fang; Ma, Yan Fen; Wen, Jing Xiao; DU, Yan Fang; Li, Chun Lin; Li, Guang Wei

    2014-07-01

    To establish the parsimonious model for blood glucose monitoring in patients with type 2 diabetes receiving oral hypoglycemic agent treatment. One hundred and fifty-nine adult Chinese type 2 diabetes patients were randomized to receive rapid-acting or sustained-release gliclazide therapy for 12 weeks. Their blood glucose levels were measured at 10 time points in a 24 h period before and after treatment, and the 24 h mean blood glucose levels were measured. Contribution of blood glucose levels to the mean blood glucose level and HbA1c was assessed by multiple regression analysis. The correlation coefficients of blood glucose level measured at 10 time points to the daily MBG were 0.58-0.74 and 0.59-0.79, respectively, before and after treatment (Pblood glucose levels measured at 6 of the 10 time points could explain 95% and 97% of the changes in MBG before and after treatment. The three blood glucose levels, which were measured at fasting, 2 h after breakfast and before dinner, of the 10 time points could explain 84% and 86% of the changes in MBG before and after treatment, but could only explain 36% and 26% of the changes in HbA1c before and after treatment, and they had a poorer correlation with the HbA1c than with the 24 h MBG. The blood glucose levels measured at fasting, 2 h after breakfast and before dinner truly reflected the change 24 h blood glucose level, suggesting that they are appropriate for the self-monitoring of blood glucose levels in diabetes patients receiving oral anti-diabetes therapy. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  19. Assessing and Promoting the Level of Safeguards Culture in Hungarian Nuclear Facilities

    International Nuclear Information System (INIS)

    Stefanka, Z.; Vincze, A.

    2015-01-01

    The Hungarian SSAC has introduced a comprehensive domestic safeguards verification system consisting of regular comprehensive SSAC verifications in the whole lifetime of the facilities. The main goals of the comprehensive verification system are: (i) to assess the facility's safeguards system compliance with the relevant national legislation and recommendations, (ii) to assess the activities of the facility aimed at maintaining and further developing its safeguards system, and, (iii) to revise validity of data and information previously provided by the facility subject to safeguards licencing procedures. The maintenance level of the system as well as the available knowledge on the possible needs for change reflect the top management's awareness of this issue and is a good indicator of the present and future effectiveness of the facility level safeguards system and the level of safeguards culture. The structure, preparation, conduction, documentation and initial experiences of the comprehensive safeguards verification system is introduced in the paper. Additionally, HAEA has just introduced a safeguards indexing method for evaluation the safeguards culture at Hungarian nuclear facilities. The main goal of indexing method and the evaluated parameters are also shown in the paper. (author)

  20. Hb Presbyterian (HBB: c.327C>G) in a Nicaraguan Family.

    Science.gov (United States)

    Pernudy-Ubau, Allan; Salinas-Molina, Jaslyn; Requenez, Yaneris; Ortiz-Lopez, Marianela; Puller, Ann-Christin; García-Rosales, Kenia; Rodríguez-Estrada, Anaishelle; Rodríguez-Romero, Walter; Mejía-Baltodano, Gerardo; Luo, Hong-Yuan; Chui, David H K

    2017-01-01

    Hemoglobin (Hb) is the protein responsible for oxygen transportation. It is a tetrameric protein comprising two α- and two β-globin subunits. In the literature, a large number of mutations in the α- and β-globin genes have been documented. Among these mutations, Hb Presbyterian (HBB: c.327 C>G), is a naturally occurring mutant exerting low oxygen affinity. The C to G exchange (AAC>AAG) at codon 108 of the β-globin gene results in the substitution of asparagine by lysine. Here, we document the identification of HBB: c.327 C>G in a 6-year-old female patient and her father from Nicaragua and Cuba, respectively. The presence of the abnormal Hb was confirmed by cellulose acetate electrophoresis, high performance liquid chromatography (HPLC) and genomic DNA sequencing. The β-globin gene sequences for both, father and daughter, disclosed the heterozygous mutation at codon 108 to be Hb Presbyterian or HBB: c.327 C>G. The mutant Hb was previously reported in four families from North America, Germany, Japan and Spain, respectively. This is the fifth family carrying HBB: c.327 C>G described to date and the first report from Latin America.

  1. Two α1-Globin Gene Point Mutations Causing Severe Hb H Disease.

    Science.gov (United States)

    Jiang, Hua; Huang, Lv-Yin; Zhen, Li; Jiang, Fan; Li, Dong-Zhi

    Hb H disease is generally a moderate form of α-thalassemia (α-thal) that rarely requires regular blood transfusions. In this study, two Chinese families with members carrying transfusion-dependent Hb H disease were investigated for rare mutations on the α-globin genes (HBA1, HBA2). In one family, Hb Zürich-Albisrieden [α59(E8)Gly→Arg; HBA1: c.178G>C] in combination with the Southeast Asian (- - SEA ) deletion was the defect responsible for the severe phenotype. In another family, a novel hemoglobin (Hb) variant named Hb Sichuan (HBA1: c.393_394insT), causes α-thal and a severe phenotype when associated with the - - SEA deletion. As these two HBA1 mutations can present as continuous blood transfusion-dependent α-thal, it is important to take this point into account for detecting the carriers, especially in couples in which one partner is already a known α 0 -thal carrier.

  2. Use of HbA1c to diagnose type 2 diabetes mellitus among high risk Sri Lankan adults.

    Science.gov (United States)

    Herath, H M M; Weerarathna, T P; Dahanayake, M U; Weerasinghe, N P

    Even though, glycosylated hemoglobin (HbA1c) was found to be effective in predicting diabetes especially in Caucasians there is limited evidence of its diagnostic utility in high risk Sri Lankan adults. This study aimed to determine the optimal HbA1c cut-off points for detecting diabetes in a high risk population in Sri Lanka. This community based study consisted of 254 previously healthy adults with history of diabetes in one or more first-degree relatives. Fasting plasma glucose (FPG) , glucose tolerance test (GTT) and HbA1c were measured in all and GTT was used as a reference to diagnose diabetes. Receiver operating characteristic curve was created to find the optimum HbA1c cut-off value to predict diabetes. Prevalence of diabetes was 12.2% (n=31) with FPG and 16.1% (n=41) with GTT. Prevalence rose to 27.6% (PHbA1c with cut-off of ≥6.5% was used as the diagnostic test. The ROC curves showed the HbA1c threshold of 6.3% provided the optimum balance between sensitivity (80.5%) and specificity (79%). In compared to GTT, FPG had only a modest sensitivity (65%) in diagnosing diabetes in this high risk population. Our study showed that optimum HbA1C cut-off for detecting diabetes was 6.3% and it had better sensitivity, but lower specificity than FPG. This study further showed that the prevalence of diabetes would become double if HbA1c is used over FPG to screen this high risk population. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  3. Error analysis of thermocouple measurements in the Radiant Heat Facility

    International Nuclear Information System (INIS)

    Nakos, J.T.; Strait, B.G.

    1980-12-01

    The measurement most frequently made in the Radiant Heat Facility is temperature, and the transducer which is used almost exclusively is the thermocouple. Other methods, such as resistance thermometers and thermistors, are used but very rarely. Since a majority of the information gathered at Radiant Heat is from thermocouples, a reasonable measure of the quality of the measurements made at the facility is the accuracy of the thermocouple temperature data

  4. White source gamma-ray production spectral measurement facilities in the USA

    International Nuclear Information System (INIS)

    Larson, D.C.; Dickens, J.K.; Nelson, R.O.; Wender, S.A.

    1991-01-01

    The two primary neutron sources for measuring gamma-ray production (GRP) cross sections for basic and applied work in the USA are the Oak Ridge Electron Linear Accelerator (ORELA) located at the Oak Ridge National Laboratory (ORNL) and the Weapons Neutron Research (WNR) facility located at the Los Alamos National Laboratory (LANL). ORELA is based on a 180-MeV electron linear accelerator, while the WNR facility uses the Los Alamos Meson Physics Facility 800 MeV proton beam to produce neutrons. The facilities collectively cover the neutron-energy range from thermal to over 700 MeV. The paper describes the present capabilities for GRP measurements at each facility. 18 refs

  5. Socioeconomic determinants of haemoglobin levels of African women are less important in areas with more health facilities: a multilevel analysis

    NARCIS (Netherlands)

    Haverkate, M; Smits, J.P.J.M.; Meijerink, H.; Ven, André van der

    2014-01-01

    BACKGROUND : The prevalence of anaemia in Africa is the highest in the world. Especially women are at risk because of blood loss during menstruation and increased iron requirements during pregnancy. This study examined determinants of the haemoglobin (Hb) level of African women at

  6. Parameters affecting level measurement interpretation of nuclear fuel solutions

    International Nuclear Information System (INIS)

    Hunt, B.A.; Landat, D.A.

    1999-01-01

    This paper describes a level measurement technique commonly used in the measurement of radioactive liquids and equipment utilised by the inspectors for safeguards purposes. Some of the influencing parameters affecting the measurement results by this technique are characterised. An essential requisite for successful process operations in chemical facilities involving liquids generally require some physical measurements to be made in-line for both process and quality control in order to achieve the necessary final product specifications . In nuclear fuel reprocessing facilities, the same objectives apply coupled however with an additional requirement of achieving nuclear material accountancy and control. In view of the strategic importance of some of the process vessels in nuclear facilities, accountancy has to be supported by volume and density measurements of low uncertainty. Inspectors therefore require instruments which are at the very least as good as or better than operator's equipment. The classical measurement technique and most widely applied for process liquids in nuclear installations is the bubbler probe or dip-tube technique. Here a regulated flow of air passes through tubes inserted to various depths into the vessel and pressure readings are measured which are a function of the presence of liquid height and density of solution in the tank. These readings, taken together with a pre-determined calibration curve are sufficient for the volume and amount of liquor in a tank to be quantified. All measurement equipment and instrumentation are long distances from the tank environment. The key physical parameter to measure at this location is therefore pressure. Equipment designed developed, commissioned and tested in the tank measurement facilities at Ispra and in nuclear installations in Europe, Japan and the USA, house digital pressure transducer modules with manufacture's declared features of better than 0.01% accuracy and long term stability of 0.01% full

  7. US Army facility for the consolidation of low-level radioactive waste

    International Nuclear Information System (INIS)

    Stein, S.L.; Tanner, J.E.; Murphy, B.L.; Gillings, J.C.; Hadley, R.T.; Lyso, O.M.; Gilchrist, R.L.; Murphy, D.W.

    1983-12-01

    A preliminary study of a waste consolidation facility for the Department of the Army's low-level radioactive waste was carried out to determine a possible site and perform a cost-benefit analysis. Four sites were assessed as possible locations for such a facility, using predetermined site selection criteria. To assist in the selection of a site, an evaluation of environmental issues was included as part of each site review. In addition, a preliminary design for a waste consolidation facility was developed, and facilities at each site were reviewed for their availability and suitability for this purpose. Currently available processes for volume reduction, as well as processes still under development, were then investigated, and the support and handling equipment and the staff needed for the safe operation of a waste consolidation facility were studied. Using current costs for the transportation and burial of low-level waste, a cost comparison was then made between waste disposal with and without the utilization of volume reduction. Finally, regulations that could affect the operation of a waste consolidation facility were identified and their impact was assessed. 11 references, 5 figures, 16 tables

  8. Licensing procedures for Low-Level Waste disposal facilities

    Energy Technology Data Exchange (ETDEWEB)

    Roop, R.D.; Van Dyke, J.W.

    1985-09-01

    This report describes the procedures applicable to siting and licensing of disposal facilities for low-level radioactive wastes. Primary emphasis is placed on those procedures which are required by regulations, but to the extent possible, non-mandatory activities which will facilitate siting and licensing are also considered. The report provides an overview of how the procedural and technical requirements for a low-level waste (LLW) disposal facility (as defined by the Nuclear Regulatory Commission's Rules 10 CFR Parts 2, 51, and 61) may be integrated with activities to reduce and resolve conflict generated by the proposed siting of a facility. General procedures are described for site screening and selection, site characterization, site evaluation, and preparation of the license application; specific procedures for several individual states are discussed. The report also examines the steps involved in the formal licensing process, including docketing and initial processing, preparation of an environmental impact statement, technical review, hearings, and decisions. It is concluded that development of effective communication between parties in conflict and the utilization of techniques to manage and resolve conflicts represent perhaps the most significant challenge for the people involved in LLW disposal in the next decade. 18 refs., 6 figs.

  9. 47 CFR 2.948 - Description of measurement facilities.

    Science.gov (United States)

    2010-10-01

    ... description of the measurement facilities employed. (1) If the measured equipment is subject to the... number; (v) FCC Registration Number (FRN); (vi) A statement as to whether or not the laboratory performs... supporting structures, and all structures within 5 times the distance between the measuring antenna and the...

  10. Lacking deoxygenation-linked interaction between cytoplasmic domain of band 3 and HbF from fetal red blood cells

    DEFF Research Database (Denmark)

    Weber, Roy E.

    2007-01-01

    Aim: Several of the red blood cell's metabolic and membrane functions display dependence on haemoglobin oxygenation. In adult human red cells, the increased glycolytic rate at low O2 tension results from binding of deoxygenated HbA at negatively charged, N-terminal, cytoplasmic domain of the memb......Aim: Several of the red blood cell's metabolic and membrane functions display dependence on haemoglobin oxygenation. In adult human red cells, the increased glycolytic rate at low O2 tension results from binding of deoxygenated HbA at negatively charged, N-terminal, cytoplasmic domain...... of the membrane protein band 3, which liberates glycolytic enzymes from this site. This study aims to investigate the role of fetal HbF (that has lower anion-binding capacity than HbA) in fetal red cells (that are subjected to low O2 tensions), and to elucidate possible linkage (e.g. via the major red cell...... membrane organising centre, band 3) between the individual oxygenation-linked reactions encountered in red cells. Methods: The interaction between band 3 and Hb is analysed in terms of the effects, measured under different conditions, of a 10-mer peptide that corresponds to the N-terminus of human band 3...

  11. Both the frequency of HbA1c testing and the frequency of self-monitoring of blood glucose predict metabolic control: A multicentre analysis of 15 199 adult type 1 diabetes patients from Germany and Austria.

    Science.gov (United States)

    Schwandt, A; Best, F; Biester, T; Grünerbel, A; Kopp, F; Krakow, D; Laimer, M; Wagner, C; Holl, R W

    2017-10-01

    The objective of this study was to examine the association between metabolic control and frequency of haemoglobin A 1c (HbA 1c ) measurements and of self-monitoring of blood glucose, as well as the interaction of both. Data of 15 199 adult type 1 diabetes patients registered in a standardized electronic health record (DPV) were included. To model the association between metabolic control and frequency of HbA 1c testing or of self-monitoring of blood glucose, multiple hierarchic regression models with adjustment for confounders were fitted. Tukey-Kramer test was used to adjust P values for multiple comparisons. Vuong test was used to compare non-nested models. The baseline variables of the study population were median age 19.9 [Q1; Q3: 18.4; 32.2] years and diabetes duration 10.4 [6.8; 15.7] years. Haemoglobin A 1c was 60.4 [51.5; 72.5] mmol/mol. Frequency of HbA 1c testing was 8.0 [5.0; 9.0] within 2 years, and daily self-monitoring of blood glucose frequency was 5.0 [4.0; 6.0]. After adjustment, a U-shaped association between metabolic control and frequency of HbA 1c testing was observed with lowest HbA 1c levels in the 3-monthly HbA 1c testing group. There was an inverse relationship between self-monitoring of blood glucose and HbA 1c with lower HbA 1c associated with highest frequency of testing (>6 daily measurements). Quarterly HbA 1c testing and frequent self-monitoring of blood glucose were associated with best metabolic control. The adjusted Vuong Z statistic suggests that metabolic control might be better explained by HbA 1c testing compared to self-monitoring of blood glucose (P < .0001). This research reveals the importance of quarterly clinical HbA 1c monitoring together with frequent self-monitoring of blood glucose in diabetes management to reach and maintain target HbA 1c . Copyright © 2017 John Wiley & Sons, Ltd.

  12. HB-EGF is necessary and sufficient for Müller glia dedifferentiation and retina regeneration

    Science.gov (United States)

    Wan, Jin; Ramachandran, Rajesh; Goldman, Daniel

    2011-01-01

    Summary Müller glia (MG) dedifferentiation into a cycling population of multipotent progenitors is crucial to zebrafish retina regeneration. The mechanisms underlying MG dedifferentiation are unknown. Here we report that heparin-binding epidermal-like growth factor (HB-EGF) is rapidly induced in MG residing at the injury site and that proHB-EGF ectodomain shedding is necessary for retina regeneration. Remarkably, HB-EGF stimulates the formation of multipotent MG-derived progenitors in the uninjured retina. We show that HB-EGF mediates its effects via an EGFR/MAPK signal transduction cascade that regulates the expression of regeneration-associated genes, like ascl1a and pax6b. We also uncover an HB-EGF/Ascl1a/Notch/hb-egfa signaling loop that helps define the zone of injury-responsive MG. Finally, we show that HB-EGF acts upstream of the Wnt/β-catenin signaling cascade that controls progenitor proliferation. These data provide a link between extracellular signaling and regeneration-associated gene expression in the injured retina and suggest strategies for stimulating retina regeneration in mammals. PMID:22340497

  13. Co-inheritance of the rare β hemoglobin variants Hb Yaounde, Hb Görwihl and Hb City of Hope with other alterations in globin genes: impact in genetic counseling.

    Science.gov (United States)

    Vinciguerra, Margherita; Passarello, Cristina; Leto, Filippo; Cassarà, Filippo; Cannata, Monica; Maggio, Aurelio; Giambona, Antonino

    2015-04-01

    Nearly 1183 different molecular defects of the globin genes leading to hemoglobin variants have been identified (http://globin.bx.psu.edu) over the past decades. The purpose of this study was to report three cases, never described in the literature, of co-inheritance of three β hemoglobin variants with other alterations in globin genes and to evaluate the clinical significance to conduct an appropriate genetic counseling. We report the molecular study performed in three probands and their families, sampling during the screening program conducted at the Laboratory for Molecular Prenatal Diagnosis of Hemoglobinopathies at Villa Sofia-Cervello Hospital in Palermo, Italy. This work allowed us to describe the co-inheritance of three rare β hemoglobin variants with other alterations in globin genes: the β hemoglobin variant Hb Yaounde [β134(H12)Val>Ala], found for the first time in combination with ααα(anti3.7) arrangement, and the β hemoglobin variants Hb Görwihl [β5(A2)Pro>Ala] and Hb City of Hope [β69(E13)Gly>Ser], found both in association with β(0) -thalassemia. The present work emphasizes the importance of a careful evaluation of the hematological data, especially in cases of atypical hematological parameters, to carry out an adequate and complete molecular study and to formulate an appropriate genetic counseling for couples at risk. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Development of novel antibacterial active, HaCaT biocompatible and biodegradable CA-g-P(3HB-EC biocomposites with caffeic acid as a functional entity

    Directory of Open Access Journals (Sweden)

    H. M. N. Iqbal

    2015-09-01

    Full Text Available We have developed novel composites by grafting caffeic acid (CA onto the P(3HB-EC based material and laccase from Trametes versicolor was used for grafting purposes. The resulting composites were designated as CA-g-P(3HB-EC i.e., P(3HB-EC (control, 5CA-g-P(3HB-EC, 10CA-g-P(3HB-EC, 15CA-g-P(3HB-EC and 20CA-g-P(3HB-EC. FT-IR (Fourier-transform infrared spectroscopy was used to examine the functional and elemental groups of the control and laccase-assisted graft composites. Evidently, 15CA-g-P(3HB-EC composite exhibited resilient antibacterial activity against Gram-positive and Gram-negative bacterial strains. Moreover, a significant level of biocompatibility and biodegradability of the CA-g-P(3HB-EC composites was also achieved with the human keratinocytes-like HaCaT cells and soil burial evaluation, respectively. In conclusion, the newly developed novel composites with multi characteristics could well represent the new wave of biomaterials for medical applications, and more specifically have promising future in the infection free would dressings, burn and/or skin regeneration field due to their sophisticated characteristics.

  15. CYP1A2 and NAT2 phenotyping and 3-aminobiphenyl and 4-aminobiphenyl hemoglobin adduct levels in smokers and non-smokers

    International Nuclear Information System (INIS)

    Sarkar, Mohamadi; Stabbert, Regina; Kinser, Robin D.; Oey, Jan; Rustemeier, Klaus; Holt, Klaus von; Schepers, Georg; Walk, Roger A.; Roethig, Hans J.

    2006-01-01

    Some aromatic amines are considered to be putative bladder carcinogens. Hemoglobin (Hb) adducts of 3-aminobiphenyl (3-ABP) and 4-aminobiphenyl (4-ABP) have been used as biomarkers of exposure to aromatic amines from cigarette smoke. One of the goals of this study was to determine intra- and inter-individual variability in 3-ABP and 4-ABP Hb adducts and to explore the predictability of ABP Hb adduct levels based on caffeine phenotyping. The study was conducted in adult smokers (S, n = 65) and non-smokers (NS, n 65). The subjects were phenotyped for CYP1A2 and NAT2 using urinary caffeine metabolites. Blood samples were collected twice within 6 weeks and adducts measured by GC/MS. The levels of 4-ABP Hb adducts were significantly (p < 0.0001) greater in S (34.5 ± 21.06 pg/g Hb) compared to NS (6.3 ± 3.02 pg/g Hb). The levels of 3-ABP Hb adducts were below the limit of quantification (BLOQ) in most (82%) of the NS and about 10-fold lower in S (3.6 ± 3.29 pg/g Hb) compared to 4-ABP Hb adducts. No differences were observed in the adduct levels between weeks 1 and 6 in the smokers, suggesting that a single sample would be adequate to monitor cigarette smoke exposure. The regression model developed with CYP1A2, NAT2 phenotype and number of cigarettes smoked (NCIG) accounted for 47% of the variability in 3-ABP adducts, whereas 32% variability in 4-ABP adducts was accounted by CYP1A2 and NCIG. The ratio of 4-ABP Hb adducts in adult S:NS was ∼ 5:1, whereas 3-ABP Hb adducts levels were BLOQ in some S, exhibited large interindividual variability (∼ 91% compared to 57% for 4-ABP Hb) and poor dose response relationship. Therefore, 4-ABP Hb adduct levels may be a more useful biomarker of aminobiphenyl exposure from cigarette smoke

  16. Use of compensation and incentives in siting low-level radioactive waste disposal facilities

    International Nuclear Information System (INIS)

    Smith, T.P.; Jaffe, M.

    1984-09-01

    In discussing the use of compensation and incentives in siting low-level radioactive waste disposal facilities, chapters are devoted to: compensation and incentives in disposal facility siting (definitions and effects of compensation and incentives and siting decisions involving the use of compensation and incentives); the impacts of regional and state low-level radioactive waste facilities; the legal framework of compensation; and recommendations regarding the use of compensation

  17. A Strategy for Quantifying Radioactive Material in a Low-Level Waste Incineration Facility

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1997-03-01

    One of the methods proposed by the U.S. Department of Energy (DOE) for the volume reduction and stabilization of a variety of low-level radioactive wastes (LLW) is incineration. Many commercial incinerators are in operation treating both non-hazardous and hazardous wastes. These can obtain volume reductions factors of 50 or more for certain wastes, and produce a waste (ash) that can be easily stabilized if necessary by vitrification or cementation. However, there are few incinerators designed to accommodate radioactive wastes. One has been recently built at the Savannah River Site (SRS) near Aiken, SC and is burning non-radioactive hazardous waste and radioactive wastes in successive campaigns. The SRS Consolidated Incineration Facility (CIF) is RCRA permitted as a Low Chemical Hazard, Radiological facility as defined by DOE criteria (Ref. 1). Accordingly, the CIF must operate within specified chemical, radionuclide, and fissile material inventory limits (Ref. 2). The radionuclide and fissile material limits are unique to radiological or nuclear facilities, and require special measurement and removal strategies to assure compliance, and the CIF may be required to shut down periodically in order to clean out the radionuclide inventory which builds up in various parts of the facility

  18. Baseline Report on HB2320

    Science.gov (United States)

    State Council of Higher Education for Virginia, 2015

    2015-01-01

    Staff provides this baseline report as a summary of its preliminary considerations and initial research in fulfillment of the requirements of HB2320 from the 2015 session of the General Assembly. Codified as § 23-7.4:7, this legislation compels the Education Secretary and the State Council of Higher Education for Virginia (SCHEV) Director, in…

  19. Stability and reliability of glycated haemoglobin measurements in blood samples stored at -20°C.

    Science.gov (United States)

    Venkataraman, Vijayachandrika; Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Jayashri, Ramamoorthy; Anbalagan, Viknesh Prabu; Akila, Bridgitte; Madhu, Sri Venkata; Lakshmy, Ramakrishnan; Mohan, Viswanathan

    2016-01-01

    To validate the stability of glycated haemoglobin (HbA1c) measurements in blood samples stored at -20°C for up to one month. The study group comprised 142 type 2 diabetic subjects visiting a tertiary centre for diabetes at Chennai city in south India. The HbA1c assay was done on a fasting blood sample using the Bio-Rad Variant machine on Day 0 (day of blood sample collection). Several aliquots were stored at -20°C and the assay was repeated on the 3rd, 7th, 15th, and 30th day after the sample collection. Bland-Altman plots were constructed and variation in the HbA1c levels on the different days was compared with the day 0 level. The median differences between HbA1c levels measured on Day 0 and the 3rd, 7th, 15th, and 30th day after blood collection were 0.0%, 0.2%, 0.3% and 0.5% respectively. Bland-Altman plot analysis showed that the differences between the day '0' and the different time points tend to get larger with time, but these were not clinically significant. HbA1c levels are relatively stable up to 2weeks, if blood samples are stored at -20°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Measurement and evaluation of the external radiation level at reactor Kartini

    International Nuclear Information System (INIS)

    Atok Suhartanto; Suparno

    2013-01-01

    Measurement and evaluation of external radiation level at reactor Kartini in 2012 has been done. The purpose of this activity is to know the external radiation level as a result of the radioactive or radiation source usage, toward the operational of limit condition. The measurement is using survey meter Inspector 11086, factor of calibration 0.991 mR/h, at 9 locations is: Control room area, Thermal column facilities, Demineralizer, Beamport radiography facilities, bulk shielding Deck, Subcritical facilities, Reactor hall, Deck reactor and on the surface of reactor water tank . The highest room average measurement result in 9 working areas for 12 months continuously are at the reactor tank location is between 13.05±1.09 (xlO -2 mSv/hour) to 16.80±1.40 (x10 -2 mSv/hour), and the lowest measurement result in 1 location (control room) is 0.02±0.005 (x10 -2 mSv/hour) to 0.035±0.009 (x10 -2 mSv/hour). The Kartini reactor is involved in the control area which has potentially contaminated and has radiation exposure at the level of 6 mSv/year. Radiation Protection Officer that work in interval will received radiation exposure dosage of 8.4 mSv/year. This dosage is still below the Below Dosage Value which is recommended by, BAPETEN decree No, 4, 2013 about Protection and Radiation Safety in Nuclear Energy Application at 20 mSv/year. The result of the evaluation above shows that the external radiation which occurred in each area is still below the operational of limit condition that is written on the Kartini reactor safety analysis report, on document number: C7/05/B2/LAK/2010, revision 7. So that the workplace is safe for work monitored. (author)