WorldWideScience

Sample records for facilitate quantitative analysis

  1. Quantitative analysis chemistry

    International Nuclear Information System (INIS)

    Ko, Wansuk; Lee, Choongyoung; Jun, Kwangsik; Hwang, Taeksung

    1995-02-01

    This book is about quantitative analysis chemistry. It is divided into ten chapters, which deal with the basic conception of material with the meaning of analysis chemistry and SI units, chemical equilibrium, basic preparation for quantitative analysis, introduction of volumetric analysis, acid-base titration of outline and experiment examples, chelate titration, oxidation-reduction titration with introduction, titration curve, and diazotization titration, precipitation titration, electrometric titration and quantitative analysis.

  2. Quantitative subsurface analysis using frequency modulated thermal wave imaging

    Science.gov (United States)

    Subhani, S. K.; Suresh, B.; Ghali, V. S.

    2018-01-01

    Quantitative depth analysis of the anomaly with an enhanced depth resolution is a challenging task towards the estimation of depth of the subsurface anomaly using thermography. Frequency modulated thermal wave imaging introduced earlier provides a complete depth scanning of the object by stimulating it with a suitable band of frequencies and further analyzing the subsequent thermal response using a suitable post processing approach to resolve subsurface details. But conventional Fourier transform based methods used for post processing unscramble the frequencies with a limited frequency resolution and contribute for a finite depth resolution. Spectral zooming provided by chirp z transform facilitates enhanced frequency resolution which can further improves the depth resolution to axially explore finest subsurface features. Quantitative depth analysis with this augmented depth resolution is proposed to provide a closest estimate to the actual depth of subsurface anomaly. This manuscript experimentally validates this enhanced depth resolution using non stationary thermal wave imaging and offers an ever first and unique solution for quantitative depth estimation in frequency modulated thermal wave imaging.

  3. Immune adherence: a quantitative and kinetic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, T [National Cancer Center, Tokyo (Japan). Research Inst.

    1978-09-01

    Quantitative and kinetic analysis of the immune-adherence reaction (IA) between C3b fragments and IA receptors as an agglutination reaction is difficult. Analysis is possible, however, by use of radio-iodinated bovine serum albumin as antigen at low concentrations (less than 200 ng/ml) and optimal concentration of antibody to avoid precipitation of antigen-antibody complexes with human erythrocytes without participation of complement. Antigen and antibody are reacted at 37/sup 0/C, complement is added, the mixture incubated and human erythrocytes added; after further incubation, ice-cold EDTA containing buffer is added and the erythrocytes centrifuged and assayed for radioactivity. Control cells reacted with heated guinea pig serum retained less than 5% of the added radioactivity. The method facilitates measurement of IA reactivity and permits more detailed analysis of the mechanism underlying the reaction.

  4. Quantitative investment analysis

    CERN Document Server

    DeFusco, Richard

    2007-01-01

    In the "Second Edition" of "Quantitative Investment Analysis," financial experts Richard DeFusco, Dennis McLeavey, Jerald Pinto, and David Runkle outline the tools and techniques needed to understand and apply quantitative methods to today's investment process.

  5. Epithelium percentage estimation facilitates epithelial quantitative protein measurement in tissue specimens.

    Science.gov (United States)

    Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui

    2013-12-01

    The rapid advancement of high-throughput tools for quantitative measurement of proteins has demonstrated the potential for the identification of proteins associated with cancer. However, the quantitative results on cancer tissue specimens are usually confounded by tissue heterogeneity, e.g. regions with cancer usually have significantly higher epithelium content yet lower stromal content. It is therefore necessary to develop a tool to facilitate the interpretation of the results of protein measurements in tissue specimens. Epithelial cell adhesion molecule (EpCAM) and cathepsin L (CTSL) are two epithelial proteins whose expressions in normal and tumorous prostate tissues were confirmed by measuring staining intensity with immunohistochemical staining (IHC). The expressions of these proteins were measured by ELISA in protein extracts from OCT embedded frozen prostate tissues. To eliminate the influence of tissue heterogeneity on epithelial protein quantification measured by ELISA, a color-based segmentation method was developed in-house for estimation of epithelium content using H&E histology slides from the same prostate tissues and the estimated epithelium percentage was used to normalize the ELISA results. The epithelium contents of the same slides were also estimated by a pathologist and used to normalize the ELISA results. The computer based results were compared with the pathologist's reading. We found that both EpCAM and CTSL levels, measured by ELISA assays itself, were greatly affected by epithelium content in the tissue specimens. Without adjusting for epithelium percentage, both EpCAM and CTSL levels appeared significantly higher in tumor tissues than normal tissues with a p value less than 0.001. However, after normalization by the epithelium percentage, ELISA measurements of both EpCAM and CTSL were in agreement with IHC staining results, showing a significant increase only in EpCAM with no difference in CTSL expression in cancer tissues. These results

  6. Calibration strategy for semi-quantitative direct gas analysis using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Gerdes, Kirk; Carter, Kimberly E.

    2011-01-01

    A process is described by which an ICP-MS equipped with an Octopole Reaction System (ORS) is calibrated using liquid phase standards to facilitate direct analysis of gas phase samples. The instrument response to liquid phase standards is analyzed to produce empirical factors relating ion generation and transmission efficiencies to standard operating parameters. Empirical factors generated for liquid phase samples are then used to produce semi-quantitative analysis of both mixed liquid/gas samples and pure gas samples. The method developed is similar to the semi-quantitative analysis algorithms in the commercial software, which have here been expanded to include gas phase elements such as Xe and Kr. Equations for prediction of relative ionization efficiencies and isotopic transmission are developed for several combinations of plasma operating conditions, which allows adjustment of limited parameters between liquid and gas injection modes. In particular, the plasma temperature and electron density are calculated from comparison of experimental results to the predictions of the Saha equation. Comparisons between operating configurations are made to determine the robustness of the analysis to plasma conditions and instrument operating parameters. Using the methods described in this research, the elemental concentrations in a liquid standard containing 45 analytes and treated as an unknown sample were quantified accurately to ± 50% for most elements using 133 Cs as a single internal reference. The method is used to predict liquid phase mercury within 12% of the actual concentration and gas phase mercury within 28% of the actual concentration. The results verify that the calibration method facilitates accurate semi-quantitative, gas phase analysis of metal species with sufficient sensitivity to quantify metal concentrations lower than 1 ppb for many metallic analytes.

  7. Implantation of the method of quantitative analysis by proton induced X-ray analysis and application to the analysis of aerosols

    International Nuclear Information System (INIS)

    Margulis, W.

    1977-09-01

    Fundamental aspects for the implementation of the method of quantitative analysis by proton induced X-ray spectroscopy are discussed. The calibration of the system was made by determining a response coefficient for selected elements, both by irradiating known amounts of these elements as well as by the use of theoretical and experimental parameters. The results obtained by these two methods agree within 5% for the analysed elements. A computer based technique of spectrum decomposition was developed to facilitate routine analysis. Finally, aerosol samples were measured as an example of a possible application of the method, and the results are discussed. (Author) [pt

  8. Usefulness of repeat coronary angiography 24 hours after balloon angioplasty to evaluate early lminal deterioration and facilitate quantitative analysis

    NARCIS (Netherlands)

    G.R. Heyndrickx (Guy); G-J. Laarman (GertJan); H. Suryapranata (Harry); F. Zijlstra (Felix); P.W.J.C. Serruys (Patrick); D.P. Foley (David); A.A. van den Bos (Arjan); J.W. Deckers (Jaap)

    1993-01-01

    textabstractBecause of the unavoidable occurrence of vessel disruption after successful coronary balloon angioplasty, the reliability of quantitative angiographic analysis in that setting has been questioned. For this reason and the suggested occurrence of delayed elastic recoil, repeat angiography

  9. GProX, a user-friendly platform for bioinformatics analysis and visualization of quantitative proteomics data.

    Science.gov (United States)

    Rigbolt, Kristoffer T G; Vanselow, Jens T; Blagoev, Blagoy

    2011-08-01

    Recent technological advances have made it possible to identify and quantify thousands of proteins in a single proteomics experiment. As a result of these developments, the analysis of data has become the bottleneck of proteomics experiment. To provide the proteomics community with a user-friendly platform for comprehensive analysis, inspection and visualization of quantitative proteomics data we developed the Graphical Proteomics Data Explorer (GProX)(1). The program requires no special bioinformatics training, as all functions of GProX are accessible within its graphical user-friendly interface which will be intuitive to most users. Basic features facilitate the uncomplicated management and organization of large data sets and complex experimental setups as well as the inspection and graphical plotting of quantitative data. These are complemented by readily available high-level analysis options such as database querying, clustering based on abundance ratios, feature enrichment tests for e.g. GO terms and pathway analysis tools. A number of plotting options for visualization of quantitative proteomics data is available and most analysis functions in GProX create customizable high quality graphical displays in both vector and bitmap formats. The generic import requirements allow data originating from essentially all mass spectrometry platforms, quantitation strategies and software to be analyzed in the program. GProX represents a powerful approach to proteomics data analysis providing proteomics experimenters with a toolbox for bioinformatics analysis of quantitative proteomics data. The program is released as open-source and can be freely downloaded from the project webpage at http://gprox.sourceforge.net.

  10. Quantitative analysis of receptor imaging

    International Nuclear Information System (INIS)

    Fu Zhanli; Wang Rongfu

    2004-01-01

    Model-based methods for quantitative analysis of receptor imaging, including kinetic, graphical and equilibrium methods, are introduced in detail. Some technical problem facing quantitative analysis of receptor imaging, such as the correction for in vivo metabolism of the tracer and the radioactivity contribution from blood volume within ROI, and the estimation of the nondisplaceable ligand concentration, is also reviewed briefly

  11. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    Science.gov (United States)

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  12. Multivariate analysis of quantitative traits can effectively classify rapeseed germplasm

    Directory of Open Access Journals (Sweden)

    Jankulovska Mirjana

    2014-01-01

    Full Text Available In this study, the use of different multivariate approaches to classify rapeseed genotypes based on quantitative traits has been presented. Tree regression analysis, PCA analysis and two-way cluster analysis were applied in order todescribe and understand the extent of genetic variability in spring rapeseed genotype by trait data. The traits which highly influenced seed and oil yield in rapeseed were successfully identified by the tree regression analysis. Principal predictor for both response variables was number of pods per plant (NP. NP and 1000 seed weight could help in the selection of high yielding genotypes. High values for both traits and oil content could lead to high oil yielding genotypes. These traits may serve as indirect selection criteria and can lead to improvement of seed and oil yield in rapeseed. Quantitative traits that explained most of the variability in the studied germplasm were classified using principal component analysis. In this data set, five PCs were identified, out of which the first three PCs explained 63% of the total variance. It helped in facilitating the choice of variables based on which the genotypes’ clustering could be performed. The two-way cluster analysissimultaneously clustered genotypes and quantitative traits. The final number of clusters was determined using bootstrapping technique. This approach provided clear overview on the variability of the analyzed genotypes. The genotypes that have similar performance regarding the traits included in this study can be easily detected on the heatmap. Genotypes grouped in the clusters 1 and 8 had high values for seed and oil yield, and relatively short vegetative growth duration period and those in cluster 9, combined moderate to low values for vegetative growth duration and moderate to high seed and oil yield. These genotypes should be further exploited and implemented in the rapeseed breeding program. The combined application of these multivariate methods

  13. Combination and Integration of Qualitative and Quantitative Analysis

    Directory of Open Access Journals (Sweden)

    Philipp Mayring

    2001-02-01

    Full Text Available In this paper, I am going to outline ways of combining qualitative and quantitative steps of analysis on five levels. On the technical level, programs for the computer-aided analysis of qualitative data offer various combinations. Where the data are concerned, the employment of categories (for instance by using qualitative content analysis allows for combining qualitative and quantitative forms of data analysis. On the individual level, the creation of types and the inductive generalisation of cases allow for proceeding from individual case material to quantitative generalisations. As for research design, different models can be distinguished (preliminary study, generalisation, elaboration, triangulation which combine qualitative and quantitative steps of analysis. Where the logic of research is concerned, it can be shown that an extended process model which combined qualitative and quantitative research can be appropriate and thus lead to an integration of the two approaches. URN: urn:nbn:de:0114-fqs010162

  14. Energy Dispersive Spectrometry and Quantitative Analysis Short Course. Introduction to X-ray Energy Dispersive Spectrometry and Quantitative Analysis

    Science.gov (United States)

    Carpenter, Paul; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    This course will cover practical applications of the energy-dispersive spectrometer (EDS) to x-ray microanalysis. Topics covered will include detector technology, advances in pulse processing, resolution and performance monitoring, detector modeling, peak deconvolution and fitting, qualitative and quantitative analysis, compositional mapping, and standards. An emphasis will be placed on use of the EDS for quantitative analysis, with discussion of typical problems encountered in the analysis of a wide range of materials and sample geometries.

  15. Inspection, visualisation and analysis of quantitative proteomics data

    OpenAIRE

    Gatto, Laurent

    2016-01-01

    Material Quantitative Proteomics and Data Analysis Course. 4 - 5 April 2016, Queen Hotel, Chester, UK Table D - Inspection, visualisation and analysis of quantitative proteomics data, Laurent Gatto (University of Cambridge)

  16. An Ibm PC/AT-Based Image Acquisition And Processing System For Quantitative Image Analysis

    Science.gov (United States)

    Kim, Yongmin; Alexander, Thomas

    1986-06-01

    In recent years, a large number of applications have been developed for image processing systems in the area of biological imaging. We have already finished the development of a dedicated microcomputer-based image processing and analysis system for quantitative microscopy. The system's primary function has been to facilitate and ultimately automate quantitative image analysis tasks such as the measurement of cellular DNA contents. We have recognized from this development experience, and interaction with system users, biologists and technicians, that the increasingly widespread use of image processing systems, and the development and application of new techniques for utilizing the capabilities of such systems, would generate a need for some kind of inexpensive general purpose image acquisition and processing system specially tailored for the needs of the medical community. We are currently engaged in the development and testing of hardware and software for a fairly high-performance image processing computer system based on a popular personal computer. In this paper, we describe the design and development of this system. Biological image processing computer systems have now reached a level of hardware and software refinement where they could become convenient image analysis tools for biologists. The development of a general purpose image processing system for quantitative image analysis that is inexpensive, flexible, and easy-to-use represents a significant step towards making the microscopic digital image processing techniques more widely applicable not only in a research environment as a biologist's workstation, but also in clinical environments as a diagnostic tool.

  17. Quantitative Moessbauer analysis

    International Nuclear Information System (INIS)

    Collins, R.L.

    1978-01-01

    The quantitative analysis of Moessbauer data, as in the measurement of Fe 3+ /Fe 2+ concentration, has not been possible because of the different mean square velocities (x 2 ) of Moessbauer nuclei at chemically different sites. A method is now described which, based on Moessbauer data at several temperatures, permits the comparison of absorption areas at (x 2 )=0. (Auth.)

  18. Quantitative assessment of in situ microbial communities affecting nuclear waste disposal

    International Nuclear Information System (INIS)

    White, D.C.

    1996-01-01

    Microbes in the environments surrounding nuclear waste depositories pose several questions regarding the protection of the surrounding communities. microbes can facilitate microbially influenced corrosion (MIC), mobilize and facilitate the transport of nuclides as well as produce gaseous emissions which can compromise containment. We have developed an analysis of the extant microbiota that is independent of quantitative recovery and subsequent growth, based on signature biomarkers analysis (SBA)

  19. Quantitative Data Analysis--In the Graduate Curriculum

    Science.gov (United States)

    Albers, Michael J.

    2017-01-01

    A quantitative research study collects numerical data that must be analyzed to help draw the study's conclusions. Teaching quantitative data analysis is not teaching number crunching, but teaching a way of critical thinking for how to analyze the data. The goal of data analysis is to reveal the underlying patterns, trends, and relationships of a…

  20. Original methods of quantitative analysis developed for diverse samples in various research fields. Quantitative analysis at NMCC

    International Nuclear Information System (INIS)

    Sera, Koichiro

    2003-01-01

    Nishina Memorial Cyclotron Center (NMCC) has been opened for nationwide-common utilization of positron nuclear medicine (PET) and PIXE since April 1993. At the present time, nearly 40 subjects of PIXE in various research fields are pursued here, and more than 50,000 samples have been analyzed up to the present. In order to perform quantitative analyses of diverse samples, technical developments in sample preparation, measurement and data analysis have been continuously carried out. Especially, a standard-free method for quantitative analysis'' made it possible to perform analysis of infinitesimal samples, powdered samples and untreated bio samples, which could not be well analyzed quantitatively in the past. The standard-free method'' and a ''powdered internal standard method'' made the process for target preparation quite easier. It has been confirmed that results obtained by these methods show satisfactory accuracy and reproducibility preventing any ambiguity coming from complicated target preparation processes. (author)

  1. Quantitative analysis of untreated bio-samples

    International Nuclear Information System (INIS)

    Sera, K.; Futatsugawa, S.; Matsuda, K.

    1999-01-01

    A standard-free method of quantitative analysis for untreated samples has been developed. For hair samples, measurements were performed by irradiating with a proton beam a few hairs as they are, and quantitative analysis was carried out by means of a standard-free method developed by ourselves. First, quantitative values of concentration of zinc were derived, then concentration of other elements was obtained by regarding zinc as an internal standard. As the result, values of concentration of sulphur for 40 samples agree well with the average value for a typical Japanese and also with each other within 20%, and validity of the present method could be confirmed. Accuracy was confirmed by comparing the results with those obtained by the usual internal standard method, too. For the purpose of a surface analysis of a bone sample, a very small incidence angle of the proton beam was used, so that both energy loss of the projectile and self-absorption of X-rays become negligible. As the result, consistent values of concentration for many elements were obtained by the standard-free method

  2. Quantitative analysis of boron by neutron radiography

    International Nuclear Information System (INIS)

    Bayuelken, A.; Boeck, H.; Schachner, H.; Buchberger, T.

    1990-01-01

    The quantitative determination of boron in ores is a long process with chemical analysis techniques. As nuclear techniques like X-ray fluorescence and activation analysis are not applicable for boron, only the neutron radiography technique, using the high neutron absorption cross section of this element, can be applied for quantitative determinations. This paper describes preliminary tests and calibration experiments carried out at a 250 kW TRIGA reactor. (orig.) [de

  3. Quantitative image analysis of synovial tissue

    NARCIS (Netherlands)

    van der Hall, Pascal O.; Kraan, Maarten C.; Tak, Paul Peter

    2007-01-01

    Quantitative image analysis is a form of imaging that includes microscopic histological quantification, video microscopy, image analysis, and image processing. Hallmarks are the generation of reliable, reproducible, and efficient measurements via strict calibration and step-by-step control of the

  4. Quantitative Auger analysis of Nb-Ge superconducting alloys

    International Nuclear Information System (INIS)

    Buitrago, R.H.

    1980-01-01

    The feasibility of using Auger electron analysis for quantitative analysis was investigated by studying Nb 3 Ge thin-film Auger data with different approaches. A method base on elemental standards gave consistent quantitative values with reported Nb-Ge data. Alloy sputter yields were also calculated and results were consistent with those for pure elements

  5. [Quantitative data analysis for live imaging of bone.

    Science.gov (United States)

    Seno, Shigeto

    Bone tissue is a hard tissue, it was difficult to observe the interior of the bone tissue alive. With the progress of microscopic technology and fluorescent probe technology in recent years, it becomes possible to observe various activities of various cells forming bone society. On the other hand, the quantitative increase in data and the diversification and complexity of the images makes it difficult to perform quantitative analysis by visual inspection. It has been expected to develop a methodology for processing microscopic images and data analysis. In this article, we introduce the research field of bioimage informatics which is the boundary area of biology and information science, and then outline the basic image processing technology for quantitative analysis of live imaging data of bone.

  6. Development of CD3 cell quantitation algorithms for renal allograft biopsy rejection assessment utilizing open source image analysis software.

    Science.gov (United States)

    Moon, Andres; Smith, Geoffrey H; Kong, Jun; Rogers, Thomas E; Ellis, Carla L; Farris, Alton B Brad

    2018-02-01

    Renal allograft rejection diagnosis depends on assessment of parameters such as interstitial inflammation; however, studies have shown interobserver variability regarding interstitial inflammation assessment. Since automated image analysis quantitation can be reproducible, we devised customized analysis methods for CD3+ T-cell staining density as a measure of rejection severity and compared them with established commercial methods along with visual assessment. Renal biopsy CD3 immunohistochemistry slides (n = 45), including renal allografts with various degrees of acute cellular rejection (ACR) were scanned for whole slide images (WSIs). Inflammation was quantitated in the WSIs using pathologist visual assessment, commercial algorithms (Aperio nuclear algorithm for CD3+ cells/mm 2 and Aperio positive pixel count algorithm), and customized open source algorithms developed in ImageJ with thresholding/positive pixel counting (custom CD3+%) and identification of pixels fulfilling "maxima" criteria for CD3 expression (custom CD3+ cells/mm 2 ). Based on visual inspections of "markup" images, CD3 quantitation algorithms produced adequate accuracy. Additionally, CD3 quantitation algorithms correlated between each other and also with visual assessment in a statistically significant manner (r = 0.44 to 0.94, p = 0.003 to algorithms presents salient correlations with established methods of CD3 quantitation. These analysis techniques are promising and highly customizable, providing a form of on-slide "flow cytometry" that can facilitate additional diagnostic accuracy in tissue-based assessments.

  7. Quantitative phase analysis by neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hee; Song, Su Ho; Lee, Jin Ho; Shim, Hae Seop [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-06-01

    This study is to apply quantitative phase analysis (QPA) by neutron diffraction to the round robin samples provided by the International Union of Crystallography(IUCr). We measured neutron diffraction patterns for mixed samples which have several different weight percentages and their unique characteristic features. Neutron diffraction method has been known to be superior to its complementary methods such as X-ray or Synchrotron, but it is still accepted as highly reliable under limited conditions or samples. Neutron diffraction has strong capability especially on oxides due to its scattering cross-section of the oxygen and it can become a more strong tool for analysis on the industrial materials with this quantitative phase analysis techniques. By doing this study, we hope not only to do one of instrument performance tests on our HRPD but also to improve our ability on the analysis of neutron diffraction data by comparing our QPA results with others from any advanced reactor facilities. 14 refs., 4 figs., 6 tabs. (Author)

  8. Quantitative standard-less XRF analysis

    International Nuclear Information System (INIS)

    Ulitzka, S.

    2002-01-01

    Full text: For most analytical tasks in the mining and associated industries matrix-matched calibrations are used for the monitoring of ore grades and process control. In general, such calibrations are product specific (iron ore, bauxite, alumina, mineral sands, cement etc.) and apply to a relatively narrow concentration range but give the best precision and accuracy for those materials. A wide range of CRMs is available and for less common materials synthetic standards can be made up from 'pure' chemicals. At times, analysis of materials with varying matrices (powders, scales, fly ash, alloys, polymers, liquors, etc.) and diverse physical shapes (non-flat, metal drillings, thin layers on substrates etc.) is required that could also contain elements which are not part of a specific calibration. A qualitative analysis can provide information about the presence of certain elements and the relative intensities of element peaks in a scan can give a rough idea about their concentrations. More often however, quantitative values are required. The paper will look into the basics of quantitative standardless analysis and show results for some well-defined CRMs. Copyright (2002) Australian X-ray Analytical Association Inc

  9. Reactor applications of quantitative diffraction analysis

    International Nuclear Information System (INIS)

    Feguson, I.F.

    1976-09-01

    Current work in quantitative diffraction analysis was presented under the main headings of: thermal systems, fast reactor systems, SGHWR applications and irradiation damage. Preliminary results are included on a comparison of various new instrumental methods of boron analysis as well as preliminary new results on Zircaloy corrosion, and materials transfer in liquid sodium. (author)

  10. Quantitative analysis of myocardial tissue with digital autofluorescence microscopy

    Directory of Open Access Journals (Sweden)

    Thomas Jensen

    2016-01-01

    Full Text Available Background: The opportunity offered by whole slide scanners of automated histological analysis implies an ever increasing importance of digital pathology. To go beyond the importance of conventional pathology, however, digital pathology may need a basic histological starting point similar to that of hematoxylin and eosin staining in conventional pathology. This study presents an automated fluorescence-based microscopy approach providing highly detailed morphological data from unstained microsections. This data may provide a basic histological starting point from which further digital analysis including staining may benefit. Methods: This study explores the inherent tissue fluorescence, also known as autofluorescence, as a mean to quantitate cardiac tissue components in histological microsections. Data acquisition using a commercially available whole slide scanner and an image-based quantitation algorithm are presented. Results: It is shown that the autofluorescence intensity of unstained microsections at two different wavelengths is a suitable starting point for automated digital analysis of myocytes, fibrous tissue, lipofuscin, and the extracellular compartment. The output of the method is absolute quantitation along with accurate outlines of above-mentioned components. The digital quantitations are verified by comparison to point grid quantitations performed on the microsections after Van Gieson staining. Conclusion: The presented method is amply described as a prestain multicomponent quantitation and outlining tool for histological sections of cardiac tissue. The main perspective is the opportunity for combination with digital analysis of stained microsections, for which the method may provide an accurate digital framework.

  11. Quantitative risk analysis of a space shuttle subsystem

    International Nuclear Information System (INIS)

    Frank, M.V.

    1989-01-01

    This paper reports that in an attempt to investigate methods for risk management other than qualitative analysis techniques, NASA has funded pilot study quantitative risk analyses for space shuttle subsystems. The authors performed one such study of two shuttle subsystems with McDonnell Douglas Astronautics Company. The subsystems were the auxiliary power units (APU) on the orbiter, and the hydraulic power units on the solid rocket booster. The technology and results of the APU study are presented in this paper. Drawing from a rich in-flight database as well as from a wealth of tests and analyses, the study quantitatively assessed the risk of APU-initiated scenarios on the shuttle during all phases of a flight mission. Damage states of interest were loss of crew/vehicle, aborted mission, and launch scrub. A quantitative risk analysis approach to deciding on important items for risk management was contrasted with the current NASA failure mode and effects analysis/critical item list approach

  12. Uncertainty of quantitative microbiological methods of pharmaceutical analysis.

    Science.gov (United States)

    Gunar, O V; Sakhno, N G

    2015-12-30

    The total uncertainty of quantitative microbiological methods, used in pharmaceutical analysis, consists of several components. The analysis of the most important sources of the quantitative microbiological methods variability demonstrated no effect of culture media and plate-count techniques in the estimation of microbial count while the highly significant effect of other factors (type of microorganism, pharmaceutical product and individual reading and interpreting errors) was established. The most appropriate method of statistical analysis of such data was ANOVA which enabled not only the effect of individual factors to be estimated but also their interactions. Considering all the elements of uncertainty and combining them mathematically the combined relative uncertainty of the test results was estimated both for method of quantitative examination of non-sterile pharmaceuticals and microbial count technique without any product. These data did not exceed 35%, appropriated for a traditional plate count methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Simplified quantitative treatment of uncertainty and interindividual variability in health risk assessment

    International Nuclear Information System (INIS)

    Bogen, K.T.

    1993-01-01

    A distinction between uncertainty (or the extent of lack of knowledge) and interindividual variability (or the extent of person-to-person heterogeneity) regarding the values of input variates must be maintained if a quantitative characterization of uncertainty in population risk or in individual risk is sought. Here, some practical methods are presented that should facilitate implementation of the analytic framework for uncertainty and variability proposed by Bogen and Spear. (1,2) Two types of methodology are discussed: one that facilitates the distinction between uncertainty and variability per se, and another that may be used to simplify quantitative analysis of distributed inputs representing either uncertainty or variability. A simple and a complex form for modeled increased risk are presented and then used to illustrate methods facilitating the distinction between uncertainty and variability in reference to characterization of both population and individual risk. Finally, a simple form of discrete probability calculus is proposed as an easily implemented, practical altemative to Monte-Carlo based procedures to quantitative integration of uncertainty and variability in risk assessment

  14. Quantitative Analysis of cardiac SPECT

    International Nuclear Information System (INIS)

    Nekolla, S.G.; Bengel, F.M.

    2004-01-01

    The quantitative analysis of myocardial SPECT images is a powerful tool to extract the highly specific radio tracer uptake in these studies. If compared to normal data bases, the uptake values can be calibrated on an individual basis. Doing so increases the reproducibility of the analysis substantially. Based on the development over the last three decades starting from planar scinitigraphy, this paper discusses the methods used today incorporating the changes due to tomographic image acquisitions. Finally, the limitations of these approaches as well as consequences from most recent hardware developments, commercial analysis packages and a wider view of the description of the left ventricle are discussed. (orig.)

  15. Good practices for quantitative bias analysis.

    Science.gov (United States)

    Lash, Timothy L; Fox, Matthew P; MacLehose, Richard F; Maldonado, George; McCandless, Lawrence C; Greenland, Sander

    2014-12-01

    Quantitative bias analysis serves several objectives in epidemiological research. First, it provides a quantitative estimate of the direction, magnitude and uncertainty arising from systematic errors. Second, the acts of identifying sources of systematic error, writing down models to quantify them, assigning values to the bias parameters and interpreting the results combat the human tendency towards overconfidence in research results, syntheses and critiques and the inferences that rest upon them. Finally, by suggesting aspects that dominate uncertainty in a particular research result or topic area, bias analysis can guide efficient allocation of sparse research resources. The fundamental methods of bias analyses have been known for decades, and there have been calls for more widespread use for nearly as long. There was a time when some believed that bias analyses were rarely undertaken because the methods were not widely known and because automated computing tools were not readily available to implement the methods. These shortcomings have been largely resolved. We must, therefore, contemplate other barriers to implementation. One possibility is that practitioners avoid the analyses because they lack confidence in the practice of bias analysis. The purpose of this paper is therefore to describe what we view as good practices for applying quantitative bias analysis to epidemiological data, directed towards those familiar with the methods. We focus on answering questions often posed to those of us who advocate incorporation of bias analysis methods into teaching and research. These include the following. When is bias analysis practical and productive? How does one select the biases that ought to be addressed? How does one select a method to model biases? How does one assign values to the parameters of a bias model? How does one present and interpret a bias analysis?. We hope that our guide to good practices for conducting and presenting bias analyses will encourage

  16. Quantitative phase analysis in industrial research

    International Nuclear Information System (INIS)

    Ahmad Monshi

    1996-01-01

    X-Ray Diffraction (XRD) is the only technique able to identify phase and all the other analytical techniques give information about the elements. Quantitative phase analysis of minerals and industrial products is logically the next step after a qualitative examination and is of great importance in industrial research. Since the application of XRD in industry, early in this century, workers were trying to develop quantitative XRD methods. In this paper some of the important methods are briefly discussed and partly compared. These methods are Internal Standard, Known Additions, Double Dilution, External Standard, Direct Comparison, Diffraction Absorption and Ratio of Slopes

  17. Perceived barriers and facilitators to mental health help-seeking in young people: a systematic review

    Directory of Open Access Journals (Sweden)

    Griffiths Kathleen M

    2010-12-01

    Full Text Available Abstract Background Adolescents and young adults frequently experience mental disorders, yet tend not to seek help. This systematic review aims to summarise reported barriers and facilitators of help-seeking in young people using both qualitative research from surveys, focus groups, and interviews and quantitative data from published surveys. It extends previous reviews through its systematic research methodology and by the inclusion of published studies describing what young people themselves perceive are the barriers and facilitators to help-seeking for common mental health problems. Methods Twenty two published studies of perceived barriers or facilitators in adolescents or young adults were identified through searches of PubMed, PsycInfo, and the Cochrane database. A thematic analysis was undertaken on the results reported in the qualitative literature and quantitative literature. Results Fifteen qualitative and seven quantitative studies were identified. Young people perceived stigma and embarrassment, problems recognising symptoms (poor mental health literacy, and a preference for self-reliance as the most important barriers to help-seeking. Facilitators were comparatively under-researched. However, there was evidence that young people perceived positive past experiences, and social support and encouragement from others as aids to the help-seeking process. Conclusions Strategies for improving help-seeking by adolescents and young adults should focus on improving mental health literacy, reducing stigma, and taking into account the desire of young people for self-reliance.

  18. Perceived barriers and facilitators to mental health help-seeking in young people: a systematic review.

    Science.gov (United States)

    Gulliver, Amelia; Griffiths, Kathleen M; Christensen, Helen

    2010-12-30

    Adolescents and young adults frequently experience mental disorders, yet tend not to seek help. This systematic review aims to summarise reported barriers and facilitators of help-seeking in young people using both qualitative research from surveys, focus groups, and interviews and quantitative data from published surveys. It extends previous reviews through its systematic research methodology and by the inclusion of published studies describing what young people themselves perceive are the barriers and facilitators to help-seeking for common mental health problems. Twenty two published studies of perceived barriers or facilitators in adolescents or young adults were identified through searches of PubMed, PsycInfo, and the Cochrane database. A thematic analysis was undertaken on the results reported in the qualitative literature and quantitative literature. Fifteen qualitative and seven quantitative studies were identified. Young people perceived stigma and embarrassment, problems recognising symptoms (poor mental health literacy), and a preference for self-reliance as the most important barriers to help-seeking. Facilitators were comparatively under-researched. However, there was evidence that young people perceived positive past experiences, and social support and encouragement from others as aids to the help-seeking process. Strategies for improving help-seeking by adolescents and young adults should focus on improving mental health literacy, reducing stigma, and taking into account the desire of young people for self-reliance.

  19. Micro-computer system for quantitative image analysis of damage microstructure

    International Nuclear Information System (INIS)

    Kohyama, A.; Kohno, Y.; Satoh, K.; Igata, N.

    1984-01-01

    Quantitative image analysis of radiation induced damage microstructure is very important in evaluating material behaviors in radiation environment. But, quite a few improvement have been seen in quantitative analysis of damage microstructure in these decades. The objective of this work is to develop new system for quantitative image analysis of damage microstructure which could improve accuracy and efficiency of data sampling and processing and could enable to get new information about mutual relations among dislocations, precipitates, cavities, grain boundaries, etc. In this system, data sampling is done with X-Y digitizer. The cavity microstructure in dual-ion irradiated 316 SS is analyzed and the effectiveness of this system is discussed. (orig.)

  20. Quantitative twoplex glycan analysis using 12C6 and 13C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry.

    Science.gov (United States)

    Váradi, Csaba; Mittermayr, Stefan; Millán-Martín, Silvia; Bones, Jonathan

    2016-12-01

    Capillary electrophoresis (CE) offers excellent efficiency and orthogonality to liquid chromatographic (LC) separations for oligosaccharide structural analysis. Combination of CE with high resolution mass spectrometry (MS) for glycan analysis remains a challenging task due to the MS incompatibility of background electrolyte buffers and additives commonly used in offline CE separations. Here, a novel method is presented for the analysis of 2-aminobenzoic acid (2-AA) labelled glycans by capillary electrophoresis coupled to mass spectrometry (CE-MS). To ensure maximum resolution and excellent precision without the requirement for excessive analysis times, CE separation conditions including the concentration and pH of the background electrolyte, the effect of applied pressure on the capillary inlet and the capillary length were evaluated. Using readily available 12/13 C 6 stable isotopologues of 2-AA, the developed method can be applied for quantitative glycan profiling in a twoplex manner based on the generation of extracted ion electropherograms (EIE) for 12 C 6 'light' and 13 C 6 'heavy' 2-AA labelled glycan isotope clusters. The twoplex quantitative CE-MS glycan analysis platform is ideally suited for comparability assessment of biopharmaceuticals, such as monoclonal antibodies, for differential glycomic analysis of clinical material for potential biomarker discovery or for quantitative microheterogeneity analysis of different glycosylation sites within a glycoprotein. Additionally, due to the low injection volume requirements of CE, subsequent LC-MS analysis of the same sample can be performed facilitating the use of orthogonal separation techniques for structural elucidation or verification of quantitative performance.

  1. Quantitative Structure-Activity Relationship Analysis of the ...

    African Journals Online (AJOL)

    Erah

    Quantitative Structure-Activity Relationship Analysis of the Anticonvulsant ... Two types of molecular descriptors, including the 2D autocorrelation ..... It is based on the simulation of natural .... clustering anticonvulsant, antidepressant, and.

  2. Quantitative detection and biological propagation of scrapie seeding activity in vitro facilitate use of prions as model pathogens for disinfection.

    Directory of Open Access Journals (Sweden)

    Sandra Pritzkow

    Full Text Available Prions are pathogens with an unusually high tolerance to inactivation and constitute a complex challenge to the re-processing of surgical instruments. On the other hand, however, they provide an informative paradigm which has been exploited successfully for the development of novel broad-range disinfectants simultaneously active also against bacteria, viruses and fungi. Here we report on the development of a methodological platform that further facilitates the use of scrapie prions as model pathogens for disinfection. We used specifically adapted serial protein misfolding cyclic amplification (PMCA for the quantitative detection, on steel wires providing model carriers for decontamination, of 263K scrapie seeding activity converting normal protease-sensitive into abnormal protease-resistant prion protein. Reference steel wires carrying defined amounts of scrapie infectivity were used for assay calibration, while scrapie-contaminated test steel wires were subjected to fifteen different procedures for disinfection that yielded scrapie titre reductions of ≤10(1- to ≥10(5.5-fold. As confirmed by titration in hamsters the residual scrapie infectivity on test wires could be reliably deduced for all examined disinfection procedures, from our quantitative seeding activity assay. Furthermore, we found that scrapie seeding activity present in 263K hamster brain homogenate or multiplied by PMCA of scrapie-contaminated steel wires both triggered accumulation of protease-resistant prion protein and was further propagated in a novel cell assay for 263K scrapie prions, i.e., cerebral glial cell cultures from hamsters. The findings from our PMCA- and glial cell culture assays revealed scrapie seeding activity as a biochemically and biologically replicative principle in vitro, with the former being quantitatively linked to prion infectivity detected on steel wires in vivo. When combined, our in vitro assays provide an alternative to titrations of biological

  3. Data from quantitative label free proteomics analysis of rat spleen

    Directory of Open Access Journals (Sweden)

    Khadar Dudekula

    2016-09-01

    Full Text Available The dataset presented in this work has been obtained using a label-free quantitative proteomic analysis of rat spleen. A robust method for extraction of proteins from rat spleen tissue and LC-MS-MS analysis was developed using a urea and SDS-based buffer. Different fractionation methods were compared. A total of 3484 different proteins were identified from the pool of all experiments run in this study (a total of 2460 proteins with at least two peptides. A total of 1822 proteins were identified from nine non-fractionated pulse gels, 2288 proteins and 2864 proteins were identified by SDS-PAGE fractionation into three and five fractions respectively. The proteomics data are deposited in ProteomeXchange Consortium via PRIDE PXD003520, Progenesis and Maxquant output are presented in the supported information. The generated list of proteins under different regimes of fractionation allow assessing the nature of the identified proteins; variability in the quantitative analysis associated with the different sampling strategy and allow defining a proper number of replicates for future quantitative analysis. Keywords: Spleen, Rat, Protein extraction, Label-free quantitative proteomics

  4. Quantitative data analysis in education a critical introduction using SPSS

    CERN Document Server

    Connolly, Paul

    2007-01-01

    This book provides a refreshing and user-friendly guide to quantitative data analysis in education for students and researchers. It assumes absolutely no prior knowledge of quantitative methods or statistics. Beginning with the very basics, it provides the reader with the knowledge and skills necessary to be able to undertake routine quantitative data analysis to a level expected of published research. Rather than focusing on teaching statistics through mathematical formulae, the book places an emphasis on using SPSS to gain a real feel for the data and an intuitive grasp of t

  5. Quantitative analysis method for ship construction quality

    Directory of Open Access Journals (Sweden)

    FU Senzong

    2017-03-01

    Full Text Available The excellent performance of a ship is assured by the accurate evaluation of its construction quality. For a long time, research into the construction quality of ships has mainly focused on qualitative analysis due to a shortage of process data, which results from limited samples, varied process types and non-standardized processes. Aiming at predicting and controlling the influence of the construction process on the construction quality of ships, this article proposes a reliability quantitative analysis flow path for the ship construction process and fuzzy calculation method. Based on the process-quality factor model proposed by the Function-Oriented Quality Control (FOQC method, we combine fuzzy mathematics with the expert grading method to deduce formulations calculating the fuzzy process reliability of the ordinal connection model, series connection model and mixed connection model. The quantitative analysis method is applied in analyzing the process reliability of a ship's shaft gear box installation, which proves the applicability and effectiveness of the method. The analysis results can be a useful reference for setting key quality inspection points and optimizing key processes.

  6. Quantitative X-ray analysis of pigments

    International Nuclear Information System (INIS)

    Araujo, M. Marrocos de

    1987-01-01

    The 'matrix-flushing' and the 'adiabatic principle' methods have been applied for the quantitative analysis through X-ray diffraction patterns of pigments and extenders mixtures, frequently used in paint industry. The results obtained have shown the usefulness of these methods, but still ask for improving their accuracy. (Author) [pt

  7. Novel approach in quantitative analysis of shearography method

    International Nuclear Information System (INIS)

    Wan Saffiey Wan Abdullah

    2002-01-01

    The application of laser interferometry in industrial non-destructive testing and material characterization is becoming more prevalent since this method provides non-contact full-field inspection of the test object. However their application only limited to the qualitative analysis, current trend has changed to the development of this method by the introduction of quantitative analysis, which attempts to detail the defect examined. This being the design feature for a ranges of object size to be examined. The growing commercial demand for quantitative analysis for NDT and material characterization is determining the quality of optical and analysis instrument. However very little attention is currently being paid to understanding, quantifying and compensating for the numerous error sources which are a function of interferometers. This paper presents a comparison of measurement analysis using the established theoretical approach and the new approach, taken into account the factor of divergence illumination and other geometrical factors. The difference in the measurement system could be associated in the error factor. (Author)

  8. Teamwork in a coronary care unit: facilitating and hindering aspects

    Directory of Open Access Journals (Sweden)

    Bethania Ferreira Goulart

    2016-06-01

    Full Text Available Abstract OBJECTIVE To identify, within a multidisciplinary team, the facilitating and hindering aspects for teamwork in a coronary care unit. METHOD A descriptive study, with qualitative and quantitative data, was carried out in the coronary care unit of a public hospital. The study population consisted of professionals working in the unit for at least one year. Those who were on leave or who were not located were excluded. The critical incident technique was used for data collection, by means of semi-structured interviews. For data analysis, content analysis and the critical incident technique were applied. RESULTS Participants were 45 professionals: 29 nursing professionals; 11 physicians; 4 physical therapists; and 1 psychologist. A total of 49 situations (77.6% with negative references; 385 behaviors (54.2% with positive references; and 182 consequences emerged (71.9% with negative references. Positive references facilitate teamwork, whereas negative references hinder it. A collaborative/communicative interprofessional relationship was evidenced as a facilitator; whereas poor collaboration among agents/inadequate management was a hindering aspect. CONCLUSION Despite the prevalence of negative situations and consequences, the emphasis on positive behaviors reveals the efforts the agents make in order to overcome obstacles and carry out teamwork.

  9. Quantitative methods for the analysis of electron microscope images

    DEFF Research Database (Denmark)

    Skands, Peter Ulrik Vallø

    1996-01-01

    The topic of this thesis is an general introduction to quantitative methods for the analysis of digital microscope images. The images presented are primarily been acquired from Scanning Electron Microscopes (SEM) and interfermeter microscopes (IFM). The topic is approached though several examples...... foundation of the thesis fall in the areas of: 1) Mathematical Morphology; 2) Distance transforms and applications; and 3) Fractal geometry. Image analysis opens in general the possibility of a quantitative and statistical well founded measurement of digital microscope images. Herein lies also the conditions...

  10. Parameter determination for quantitative PIXE analysis using genetic algorithms

    International Nuclear Information System (INIS)

    Aspiazu, J.; Belmont-Moreno, E.

    1996-01-01

    For biological and environmental samples, PIXE technique is in particular advantage for elemental analysis, but the quantitative analysis implies accomplishing complex calculations that require the knowledge of more than a dozen parameters. Using a genetic algorithm, the authors give here an account of the procedure to obtain the best values for the parameters necessary to fit the efficiency for a X-ray detector. The values for some variables involved in quantitative PIXE analysis, were manipulated in a similar way as the genetic information is treated in a biological process. The authors carried out the algorithm until they reproduce, within the confidence interval, the elemental concentrations corresponding to a reference material

  11. Quantitative Analysis of Geometric Structures and Experimental Evaluation of Rooster Beak

    Directory of Open Access Journals (Sweden)

    Xinping Li

    2016-06-01

    Full Text Available Quantitative analysis of rooster beak maxillary bone is highly significant to reveal the mechanism of the easy discretization and low damage in kernel dispersal. A 3D scanner is used to collect point-cloud data of rooster beak as well as extract maxillary bone horizontal and longitudinal feature curves into Matlab for curve fitting and curvature analysis. Results show that curvature values of crosscutting curves increase from side to center. These values sharply increase when curves move from side close to the center. Curvature values of the longitudinal cutting feature curves of the rooster beak maxillary bone are evidently less than those of the crosscutting curves. Geometry characteristics of rooster beak facilitate the dispersal of corn ear. High-speed photography showed that, the beak can efficiently destroy the arrangement law between kernels, and the corn ear is dispersed. The discrete roller is based on the model of the rooster beak. The experiment of discrete roller showed that the discrete and damage rates of the dent corn are 77.34% and 0.19%, respectively. The discrete and damage rates of the flint corn are 31.19% and 0.29%, respectively, under discrete roller speed of 250 rev·min-1 and moisture content of corn ear of 14.5%.

  12. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Foltz, R.L.

    1978-01-01

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ 9 -tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  13. Quantitative analysis of γ-oryzanol content in cold pressed rice bran oil by TLC-image analysis method.

    Science.gov (United States)

    Sakunpak, Apirak; Suksaeree, Jirapornchai; Monton, Chaowalit; Pathompak, Pathamaporn; Kraisintu, Krisana

    2014-02-01

    To develop and validate an image analysis method for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. TLC-densitometric and TLC-image analysis methods were developed, validated, and used for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. The results obtained by these two different quantification methods were compared by paired t-test. Both assays provided good linearity, accuracy, reproducibility and selectivity for determination of γ-oryzanol. The TLC-densitometric and TLC-image analysis methods provided a similar reproducibility, accuracy and selectivity for the quantitative determination of γ-oryzanol in cold pressed rice bran oil. A statistical comparison of the quantitative determinations of γ-oryzanol in samples did not show any statistically significant difference between TLC-densitometric and TLC-image analysis methods. As both methods were found to be equal, they therefore can be used for the determination of γ-oryzanol in cold pressed rice bran oil.

  14. Quantitative scenario analysis of low and intermediate level radioactive repository

    International Nuclear Information System (INIS)

    Lee, Keon Jae; Lee, Sang Yoon; Park, Keon Baek; Song, Min Cheon; Lee, Ho Jin

    1998-03-01

    Derivation of hypothetical radioactive waste disposal facility os conducted through sub-component characteristic analysis and conceptual modeling. It is studied that quantitative analysis of constructed scenario in terms of annual effective dose equivalent. This study is sequentially conducted according to performance assessment of radioactive waste disposal facility such as : ground water flow analysis, source term analysis, ground water transport, surface water transport, dose and pathways. The routine program module such as VAM2D-PAGAN-GENII is used for quantitative scenario analysis. Detailed data used in this module are come from experimental data of Korean territory and default data given within this module. Is case of blank data for code execution, it is estimated through reasonable engineering sense

  15. Microchromatography of hemoglobins. VIII. A general qualitative and quantitative method in plastic drinking straws and the quantitative analysis of Hb-F.

    Science.gov (United States)

    Schroeder, W A; Pace, L A

    1978-03-01

    The microchromatographic procedure for the quantitative analysis of the hemoglobin components in a hemolysate uses columns of DEAE-cellulose in a plastic drinking straw with a glycine-KCN-NaCl developer. Not only may the method be used for the quantitative analysis of Hb-F but also for the analysis of the varied components in mixtures of hemoglobins.

  16. Development of software tools for 4-D visualization and quantitative analysis of PHITS simulation results

    International Nuclear Information System (INIS)

    Furutaka, Kazuyoshi

    2015-02-01

    A suite of software tools has been developed to facilitate the development of apparatus using a radiation transport simulation code PHITS by enabling 4D visualization (3D space and time) and quantitative analysis of so-called dieaway plots. To deliver useable tools as soon as possible, the existing software was utilized as much as possible; ParaView will be used for the 4D visualization of the results, whereas the analyses of dieaway plots will be done with ROOT toolkit with a tool named “diana”. To enable 4D visualization using ParaView, a group of tools (angel2vtk, DispDCAS1, CamPos) has been developed for the conversion of the data format to the one which can be read from ParaView and to ease the visualization. (author)

  17. Quantitative genetic analysis of total glucosinolate, oil and protein ...

    African Journals Online (AJOL)

    Quantitative genetic analysis of total glucosinolate, oil and protein contents in Ethiopian mustard ( Brassica carinata A. Braun) ... Seeds were analyzed using HPLC (glucosinolates), NMR (oil) and NIRS (protein). Analyses of variance, Hayman's method of diallel analysis and a mixed linear model of genetic analysis were ...

  18. Strategies facilitating practice change in pediatric cancer: a systematic review.

    Science.gov (United States)

    Robinson, Paula D; Dupuis, Lee L; Tomlinson, George; Phillips, Bob; Greenberg, Mark; Sung, Lillian

    2016-09-01

    By conducting a systematic review, we describe strategies to actively disseminate knowledge or facilitate practice change among healthcare providers caring for children with cancer and we evaluate the effectiveness of these strategies. We searched Ovid Medline, EMBASE and PsychINFO. Fully published primary studies were included if they evaluated one or more professional intervention strategies to actively disseminate knowledge or facilitate practice change in pediatric cancer or hematopoietic stem cell transplantation. Data extracted included study characteristics and strategies evaluated. In studies with a quantitative analysis of patient outcomes, the relationship between study-level characteristics and statistically significant primary analyses was evaluated. Of 20 644 titles and abstracts screened, 146 studies were retrieved in full and 60 were included. In 20 studies, quantitative evaluation of patient outcomes was examined and a primary outcome was stated. Eighteen studies were 'before and after' design; there were no randomized studies. All studies were at risk for bias. Interrupted time series was never the primary analytic approach. No specific strategy type was successful at improving patient outcomes. Literature describing strategies to facilitate practice change in pediatric cancer is emerging. However, major methodological limitations exist. Studies with robust designs are required to identify effective strategies to effect practice change. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Quantiprot - a Python package for quantitative analysis of protein sequences.

    Science.gov (United States)

    Konopka, Bogumił M; Marciniak, Marta; Dyrka, Witold

    2017-07-17

    The field of protein sequence analysis is dominated by tools rooted in substitution matrices and alignments. A complementary approach is provided by methods of quantitative characterization. A major advantage of the approach is that quantitative properties defines a multidimensional solution space, where sequences can be related to each other and differences can be meaningfully interpreted. Quantiprot is a software package in Python, which provides a simple and consistent interface to multiple methods for quantitative characterization of protein sequences. The package can be used to calculate dozens of characteristics directly from sequences or using physico-chemical properties of amino acids. Besides basic measures, Quantiprot performs quantitative analysis of recurrence and determinism in the sequence, calculates distribution of n-grams and computes the Zipf's law coefficient. We propose three main fields of application of the Quantiprot package. First, quantitative characteristics can be used in alignment-free similarity searches, and in clustering of large and/or divergent sequence sets. Second, a feature space defined by quantitative properties can be used in comparative studies of protein families and organisms. Third, the feature space can be used for evaluating generative models, where large number of sequences generated by the model can be compared to actually observed sequences.

  20. The usefulness of 3D quantitative analysis with using MRI for measuring osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Park, Youn Soo

    2006-01-01

    We wanted to evaluate the usefulness of MRI 3D quantitative analysis for measuring osteonecrosis of the femoral head in comparison with MRI 2D quantitative analysis and quantitative analysis of the specimen. For 3 months at our hospital, 14 femoral head specimens with osteonecrosis were obtained after total hip arthroplasty. The patients preoperative MRIs were retrospectively reviewed for quantitative analysis of the size of the necrosis. Each necrotic fraction of the femoral head was measured by 2D quantitative analysis with using mid-coronal and mid-sagittal MRIs, and by 3D quantitative analysis with using serial continuous coronal MRIs and 3D reconstruction software. The necrotic fraction of the specimen was physically measured by the fluid displacement method. The necrotic fraction according to MRI 2D or 3D quantitative analysis was compared with that of the specimen by using Spearman's correlation test. On the correlative analysis, the necrotic fraction by MRI 2D quantitative analysis and quantitative analysis of the specimen showed moderate correlation (r = 0.657); on the other hand, the necrotic fraction by MRI 3D quantitative analysis and quantitative analysis of the specimen demonstrated a strong correlation (r = 0.952) (ρ < 0.05). MRI 3D quantitative analysis was more accurate than 2D quantitative analysis using MRI for measuring osteonecrosis of the femoral head. Therefore, it may be useful for predicting the clinical outcome and deciding the proper treatment option

  1. What Really Happens in Quantitative Group Research? Results of a Content Analysis of Recent Quantitative Research in "JSGW"

    Science.gov (United States)

    Boyle, Lauren H.; Whittaker, Tiffany A.; Eyal, Maytal; McCarthy, Christopher J.

    2017-01-01

    The authors conducted a content analysis on quantitative studies published in "The Journal for Specialists in Group Work" ("JSGW") between 2012 and 2015. This brief report provides a general overview of the current practices of quantitative group research in counseling. The following study characteristics are reported and…

  2. Quantitative proteomic analysis of post-translational modifications of human histones

    DEFF Research Database (Denmark)

    Beck, Hans Christian; Nielsen, Eva C; Matthiesen, Rune

    2006-01-01

    , and H4 in a site-specific and dose-dependent manner. This unbiased analysis revealed that a relative increase in acetylated peptide from the histone variants H2A, H2B, and H4 was accompanied by a relative decrease of dimethylated Lys(57) from histone H2B. The dose-response results obtained...... by quantitative proteomics of histones from HDACi-treated cells were consistent with Western blot analysis of histone acetylation, cytotoxicity, and dose-dependent expression profiles of p21 and cyclin A2. This demonstrates that mass spectrometry-based quantitative proteomic analysis of post-translational...

  3. Data from quantitative label free proteomics analysis of rat spleen.

    Science.gov (United States)

    Dudekula, Khadar; Le Bihan, Thierry

    2016-09-01

    The dataset presented in this work has been obtained using a label-free quantitative proteomic analysis of rat spleen. A robust method for extraction of proteins from rat spleen tissue and LC-MS-MS analysis was developed using a urea and SDS-based buffer. Different fractionation methods were compared. A total of 3484 different proteins were identified from the pool of all experiments run in this study (a total of 2460 proteins with at least two peptides). A total of 1822 proteins were identified from nine non-fractionated pulse gels, 2288 proteins and 2864 proteins were identified by SDS-PAGE fractionation into three and five fractions respectively. The proteomics data are deposited in ProteomeXchange Consortium via PRIDE PXD003520, Progenesis and Maxquant output are presented in the supported information. The generated list of proteins under different regimes of fractionation allow assessing the nature of the identified proteins; variability in the quantitative analysis associated with the different sampling strategy and allow defining a proper number of replicates for future quantitative analysis.

  4. Quantitative analysis of some brands of chloroquine tablets ...

    African Journals Online (AJOL)

    Quantitative analysis of some brands of chloroquine tablets marketed in Maiduguri using spectrophotometric ... and compared with that of the standard, wavelength of maximum absorbance at 331nm for chloroquine. ... HOW TO USE AJOL.

  5. Accurate quantitative XRD phase analysis of cement clinkers

    International Nuclear Information System (INIS)

    Kern, A.

    2002-01-01

    Full text: Knowledge about the absolute phase abundance in cement clinkers is a requirement for both, research and quality control. Traditionally, quantitative analysis of cement clinkers has been carried out by theoretical normative calculation from chemical analysis using the so-called Bogue method or by optical microscopy. Therefore chemical analysis, mostly performed by X-ray fluorescence (XRF), forms the basis of cement plan control by providing information for proportioning raw materials, adjusting kiln and burning conditions, as well as cement mill feed proportioning. In addition, XRF is of highest importance with respect to the environmentally relevant control of waste recovery raw materials and alternative fuels, as well as filters, plants and sewage. However, the performance of clinkers and cements is governed by the mineralogy and not the elemental composition, and the deficiencies and inherent errors of Bogue as well as microscopic point counting are well known. With XRD and Rietveld analysis a full quantitative analysis of cement clinkers can be performed providing detailed mineralogical information about the product. Until recently several disadvantages prevented the frequent application of the Rietveld method in the cement industry. As the measurement of a full pattern is required, extended measurement times made an integration of this method into existing automation environments difficult. In addition, several drawbacks of existing Rietveld software such as complexity, low performance and severe numerical instability were prohibitive for automated use. The latest developments of on-line instrumentation, as well as dedicated Rietveld software for quantitative phase analysis (TOPAS), now make a decisive breakthrough possible. TOPAS not only allows the analysis of extremely complex phase mixtures in the shortest time possible, but also a fully automated online phase analysis for production control and quality management, free of any human interaction

  6. Automated image analysis for quantitative fluorescence in situ hybridization with environmental samples.

    Science.gov (United States)

    Zhou, Zhi; Pons, Marie Noëlle; Raskin, Lutgarde; Zilles, Julie L

    2007-05-01

    When fluorescence in situ hybridization (FISH) analyses are performed with complex environmental samples, difficulties related to the presence of microbial cell aggregates and nonuniform background fluorescence are often encountered. The objective of this study was to develop a robust and automated quantitative FISH method for complex environmental samples, such as manure and soil. The method and duration of sample dispersion were optimized to reduce the interference of cell aggregates. An automated image analysis program that detects cells from 4',6'-diamidino-2-phenylindole (DAPI) micrographs and extracts the maximum and mean fluorescence intensities for each cell from corresponding FISH images was developed with the software Visilog. Intensity thresholds were not consistent even for duplicate analyses, so alternative ways of classifying signals were investigated. In the resulting method, the intensity data were divided into clusters using fuzzy c-means clustering, and the resulting clusters were classified as target (positive) or nontarget (negative). A manual quality control confirmed this classification. With this method, 50.4, 72.1, and 64.9% of the cells in two swine manure samples and one soil sample, respectively, were positive as determined with a 16S rRNA-targeted bacterial probe (S-D-Bact-0338-a-A-18). Manual counting resulted in corresponding values of 52.3, 70.6, and 61.5%, respectively. In two swine manure samples and one soil sample 21.6, 12.3, and 2.5% of the cells were positive with an archaeal probe (S-D-Arch-0915-a-A-20), respectively. Manual counting resulted in corresponding values of 22.4, 14.0, and 2.9%, respectively. This automated method should facilitate quantitative analysis of FISH images for a variety of complex environmental samples.

  7. Global scaling for semi-quantitative analysis in FP-CIT SPECT.

    Science.gov (United States)

    Kupitz, D; Apostolova, I; Lange, C; Ulrich, G; Amthauer, H; Brenner, W; Buchert, R

    2014-01-01

    Semi-quantitative characterization of dopamine transporter availability from single photon emission computed tomography (SPECT) with 123I-ioflupane (FP-CIT) is based on uptake ratios relative to a reference region. The aim of this study was to evaluate the whole brain as reference region for semi-quantitative analysis of FP-CIT SPECT. The rationale was that this might reduce statistical noise associated with the estimation of non-displaceable FP-CIT uptake. 150 FP-CIT SPECTs were categorized as neurodegenerative or non-neurodegenerative by an expert. Semi-quantitative analysis of specific binding ratios (SBR) was performed with a custom-made tool based on the Statistical Parametric Mapping software package using predefined regions of interest (ROIs) in the anatomical space of the Montreal Neurological Institute. The following reference regions were compared: predefined ROIs for frontal and occipital lobe and whole brain (without striata, thalamus and brainstem). Tracer uptake in the reference region was characterized by the mean, median or 75th percentile of its voxel intensities. The area (AUC) under the receiver operating characteristic curve was used as performance measure. The highest AUC of 0.973 was achieved by the SBR of the putamen with the 75th percentile in the whole brain as reference. The lowest AUC for the putamen SBR of 0.937 was obtained with the mean in the frontal lobe as reference. We recommend the 75th percentile in the whole brain as reference for semi-quantitative analysis in FP-CIT SPECT. This combination provided the best agreement of the semi-quantitative analysis with visual evaluation of the SPECT images by an expert and, therefore, is appropriate to support less experienced physicians.

  8. Quantitative possibility analysis. Present status in ESCA

    International Nuclear Information System (INIS)

    Brion, D.

    1981-01-01

    A short review of the recent developments in quantification of X-ray photoelectron spectroscopy or ESCA is presented. The basic equations are reminded. Each involved parameter (photoionisation, inelastic mean free paths, 'response function' of the instruments, intensity measurement) is separately discussed in relation with the accuracy and the precision of the method. Other topics are considered such as roughness, surface contamination, matrix effect and inhomogeneous composition. Some aspects of the quantitative ESCA analysis and AES analysis are compared [fr

  9. Fabrication of type I collagen microcarrier using a microfluidic 3D T-junction device and its application for the quantitative analysis of cell-ECM interactions.

    Science.gov (United States)

    Yoon, Junghyo; Kim, Jaehoon; Jeong, Hyo Eun; Sudo, Ryo; Park, Myung-Jin; Chung, Seok

    2016-08-26

    We presented a new quantitative analysis for cell and extracellular matrix (ECM) interactions, using cell-coated ECM hydrogel microbeads (hydrobeads) made of type I collagen. The hydrobeads can carry cells as three-dimensional spheroidal forms with an ECM inside, facilitating a direct interaction between the cells and ECM. The cells on hydrobeads do not have a hypoxic core, which opens the possibility for using as a cell microcarrier for bottom-up tissue reconstitution. This technique can utilize various types of cells, even MDA-MB-231 cells, which have weak cell-cell interactions and do not form spheroids in conventional spheroid culture methods. Morphological indices of the cell-coated hydrobead visually present cell-ECM interactions in a quantitative manner.

  10. Public and patient involvement in quantitative health research: A statistical perspective.

    Science.gov (United States)

    Hannigan, Ailish

    2018-06-19

    The majority of studies included in recent reviews of impact for public and patient involvement (PPI) in health research had a qualitative design. PPI in solely quantitative designs is underexplored, particularly its impact on statistical analysis. Statisticians in practice have a long history of working in both consultative (indirect) and collaborative (direct) roles in health research, yet their perspective on PPI in quantitative health research has never been explicitly examined. To explore the potential and challenges of PPI from a statistical perspective at distinct stages of quantitative research, that is sampling, measurement and statistical analysis, distinguishing between indirect and direct PPI. Statistical analysis is underpinned by having a representative sample, and a collaborative or direct approach to PPI may help achieve that by supporting access to and increasing participation of under-represented groups in the population. Acknowledging and valuing the role of lay knowledge of the context in statistical analysis and in deciding what variables to measure may support collective learning and advance scientific understanding, as evidenced by the use of participatory modelling in other disciplines. A recurring issue for quantitative researchers, which reflects quantitative sampling methods, is the selection and required number of PPI contributors, and this requires further methodological development. Direct approaches to PPI in quantitative health research may potentially increase its impact, but the facilitation and partnership skills required may require further training for all stakeholders, including statisticians. © 2018 The Authors Health Expectations published by John Wiley & Sons Ltd.

  11. Uncertainties in elemental quantitative analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Paschoa, A.S.; Barros Leite, C.V.

    1979-01-01

    The effects of the degree of non-uniformity of the particle beam, matrix composition and matrix thickness in a quantitative elemental analysis by particle induced X-ray emission (PIXE) are discussed and a criterion to evaluate the resulting degree of uncertainty in the mass determination by this method is established. (Auth.)

  12. Quantitative analysis of γ-oryzanol content in cold pressed rice bran oil by TLC-image analysis method

    OpenAIRE

    Sakunpak, Apirak; Suksaeree, Jirapornchai; Monton, Chaowalit; Pathompak, Pathamaporn; Kraisintu, Krisana

    2014-01-01

    Objective: To develop and validate an image analysis method for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. Methods: TLC-densitometric and TLC-image analysis methods were developed, validated, and used for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. The results obtained by these two different quantification methods were compared by paired t-test. Results: Both assays provided good linearity, accuracy, reproducibility and selectivity for dete...

  13. Evaluation of breast lesions by contrast enhanced ultrasound: Qualitative and quantitative analysis

    International Nuclear Information System (INIS)

    Wan Caifeng; Du Jing; Fang Hua; Li Fenghua; Wang Lin

    2012-01-01

    Objective: To evaluate and compare the diagnostic performance of qualitative, quantitative and combined analysis for characterization of breast lesions in contrast enhanced ultrasound (CEUS), with histological results used as the reference standard. Methods: Ninety-one patients with 91 breast lesions BI-RADS 3–5 at US or mammography underwent CEUS. All lesions underwent qualitative and quantitative enhancement evaluation. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of different analytical method for discrimination between benign and malignant breast lesions. Results: Histopathologic analysis of the 91 lesions revealed 44 benign and 47 malignant. For qualitative analysis, benign and malignant lesions differ significantly in enhancement patterns (p z1 ), 0.768 (A z2 ) and 0.926(A z3 ) respectively. The values of A z1 and A z3 were significantly higher than that for A z2 (p = 0.024 and p = 0.008, respectively). But there was no significant difference between the values of A z1 and A z3 (p = 0.625). Conclusions: The diagnostic performance of qualitative and combined analysis was significantly higher than that for quantitative analysis. Although quantitative analysis has the potential to differentiate benign from malignant lesions, it has not yet improved the final diagnostic accuracy.

  14. New Approach to Quantitative Analysis by Laser-induced Breakdown Spectroscopy

    International Nuclear Information System (INIS)

    Lee, D. H.; Kim, T. H.; Yun, J. I.; Jung, E. C.

    2009-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been studied as the technique of choice in some particular situations like screening, in situ measurement, process monitoring, hostile environments, etc. Especially, LIBS can fulfill the qualitative and quantitative analysis for radioactive high level waste (HLW) glass in restricted experimental conditions. Several ways have been suggested to get quantitative information from LIBS. The one approach is to use the absolute intensities of each element. The other approach is to use the elemental emission intensities relative to the intensity of the internal standard element whose concentration is known already in the specimen. But these methods are not applicable to unknown samples. In the present work, we introduce new approach to LIBS quantitative analysis by using H α (656.28 nm) emission line as external standard

  15. Multicomponent quantitative spectroscopic analysis without reference substances based on ICA modelling.

    Science.gov (United States)

    Monakhova, Yulia B; Mushtakova, Svetlana P

    2017-05-01

    A fast and reliable spectroscopic method for multicomponent quantitative analysis of targeted compounds with overlapping signals in complex mixtures has been established. The innovative analytical approach is based on the preliminary chemometric extraction of qualitative and quantitative information from UV-vis and IR spectral profiles of a calibration system using independent component analysis (ICA). Using this quantitative model and ICA resolution results of spectral profiling of "unknown" model mixtures, the absolute analyte concentrations in multicomponent mixtures and authentic samples were then calculated without reference solutions. Good recoveries generally between 95% and 105% were obtained. The method can be applied to any spectroscopic data that obey the Beer-Lambert-Bouguer law. The proposed method was tested on analysis of vitamins and caffeine in energy drinks and aromatic hydrocarbons in motor fuel with 10% error. The results demonstrated that the proposed method is a promising tool for rapid simultaneous multicomponent analysis in the case of spectral overlap and the absence/inaccessibility of reference materials.

  16. ImatraNMR: Novel software for batch integration and analysis of quantitative NMR spectra

    Science.gov (United States)

    Mäkelä, A. V.; Heikkilä, O.; Kilpeläinen, I.; Heikkinen, S.

    2011-08-01

    Quantitative NMR spectroscopy is a useful and important tool for analysis of various mixtures. Recently, in addition of traditional quantitative 1D 1H and 13C NMR methods, a variety of pulse sequences aimed for quantitative or semiquantitative analysis have been developed. To obtain actual usable results from quantitative spectra, they must be processed and analyzed with suitable software. Currently, there are many processing packages available from spectrometer manufacturers and third party developers, and most of them are capable of analyzing and integration of quantitative spectra. However, they are mainly aimed for processing single or few spectra, and are slow and difficult to use when large numbers of spectra and signals are being analyzed, even when using pre-saved integration areas or custom scripting features. In this article, we present a novel software, ImatraNMR, designed for batch analysis of quantitative spectra. In addition to capability of analyzing large number of spectra, it provides results in text and CSV formats, allowing further data-analysis using spreadsheet programs or general analysis programs, such as Matlab. The software is written with Java, and thus it should run in any platform capable of providing Java Runtime Environment version 1.6 or newer, however, currently it has only been tested with Windows and Linux (Ubuntu 10.04). The software is free for non-commercial use, and is provided with source code upon request.

  17. Trans individuals' facilitative coping: An analysis of internal and external processes.

    Science.gov (United States)

    Budge, Stephanie L; Chin, Mun Yuk; Minero, Laura P

    2017-01-01

    Existing research on trans individuals has primarily focused on their negative experiences and has disproportionately examined coming-out processes and identity development stages. Using a grounded theory approach, this qualitative study sought to examine facilitative coping processes among trans-identified individuals. Facilitative coping was operationalized as processes whereby individuals seek social support, learn new skills, change behaviors to positively adapt, and find alternative means to seek personal growth and acceptance. The sample included 15 participants who self-identified with a gender identity that was different from their assigned sex at birth. Results yielded a total of nine overarching themes: Accepting Support from Others, Actions to Increase Protection, Active Engagement Throughout the Transition Process, Actively Seeking Social Interactions, Engaging in Exploration, Internal Processes Leading to Self-Acceptance, Self-Efficacy, Shifts Leading to Embracing Change and Flexibility, and Utilization of Agency. Based on the analysis, a theoretical model emerged that highlighted the importance of internal and external coping processes in facilitating gender identity development and navigating stressors among trans individuals. Clinical implications focusing on how to implement facilitative coping processes are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Trade Facilitation Provisions in Regional Trade Agreements: Discriminatory or Non-discriminatory?

    Directory of Open Access Journals (Sweden)

    Innwon Park

    2016-12-01

    Full Text Available The RTAs with trade facilitation provisions have been expected to generate a larger net trade-creating effect and complement the discriminatory feature of RTAs but have yet to be empirically proven. Recognizing the limitations of existing studies, we conducted a quantitative analysis on the effects of RTAs with and without trade facilitation provisions on both intra- and extra-bloc trade by using a modified gravity equation. We applied the Poisson Pseudo-Maximum Likelihood (PPML estimation with time varying exporter and importer fixed effect method to panel data consisting of 45,770 country pairs covering 170 countries for 2000-2010. We found that the trade facilitation provisions in existing RTAs are non-discriminatory by generating more intra- and extra-bloc trade in general. In particular, we found that the trade effects of RTAs in the APEC region are much stronger than the general case covering all RTAs in the world. In addition, as we control the trade effect of a country's trade facilitation, which is ranked by the World Bank's logistic performance index, RTAs consisting of trade facilitation provisions are discriminatory for trade in final goods and non-discriminatory for trade in intermediate goods. Overall, we endeavor to "explain," instead of "hypothesizing," why most of the recent RTAs contain trade facilitation provisions, especially in light of the deepening regional interdependence through trade in parts and components under global value chains and support the necessity of multilateralizing RTAs by implementing non-discriminatory trade facilitation provisions.

  19. Facilitation of self-empowerment of women living with borderline personality disorder: A concept analysis

    Directory of Open Access Journals (Sweden)

    N. Ntshingila

    2016-10-01

    Objective: : The objective is to define the central concept of “facilitation of self empowerment”. Method: Analysis and synthesis reasoning methods as indicated by Walker and Avant (2011 were used to define the central concept. Results: A definition of the concept “facilitation of self-empowerment” was formulated from the dictionary and subject definitions. Conclusion: The central concept is important for developing a model as a frame of reference to assist psychiatric nurse practitioners in facilitating the mental health of women living with borderline personality disorder.

  20. Quantitative analysis by nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wainai, T; Mashimo, K [Nihon Univ., Tokyo. Coll. of Science and Engineering

    1976-04-01

    Recent papers on the practical quantitative analysis by nuclear magnetic resonance spectroscopy (NMR) are reviewed. Specifically, the determination of moisture in liquid N/sub 2/O/sub 4/ as an oxidizing agent for rocket propulsion, the analysis of hydroperoxides, the quantitative analysis using a shift reagent, the analysis of aromatic sulfonates, and the determination of acids and bases are reviewed. Attention is paid to the accuracy. The sweeping velocity and RF level in addition to the other factors must be on the optimal condition to eliminate the errors, particularly when computation is made with a machine. Higher sweeping velocity is preferable in view of S/N ratio, but it may be limited to 30 Hz/s. The relative error in the measurement of area is generally 1%, but when those of dilute concentration and integrated, the error will become smaller by one digit. If impurities are treated carefully, the water content on N/sub 2/O/sub 4/ can be determined with accuracy of about 0.002%. The comparison method between peak heights is as accurate as that between areas, when the uniformity of magnetic field and T/sub 2/ are not questionable. In the case of chemical shift movable due to content, the substance can be determined by the position of the chemical shift. Oil and water contents in rape-seed, peanuts, and sunflower-seed are determined by measuring T/sub 1/ with 90 deg pulses.

  1. Stable Isotope Quantitative N-Glycan Analysis by Liquid Separation Techniques and Mass Spectrometry.

    Science.gov (United States)

    Mittermayr, Stefan; Albrecht, Simone; Váradi, Csaba; Millán-Martín, Silvia; Bones, Jonathan

    2017-01-01

    Liquid phase separation analysis and subsequent quantitation remains a challenging task for protein-derived oligosaccharides due to their inherent structural complexity and diversity. Incomplete resolution or co-detection of multiple glycan species complicates peak area-based quantitation and associated statistical analysis when optical detection methods are used. The approach outlined herein describes the utilization of stable isotope variants of commonly used fluorescent tags that allow for mass-based glycan identification and relative quantitation following separation by liquid chromatography (LC) or capillary electrophoresis (CE). Comparability assessment of glycoprotein-derived oligosaccharides is performed by derivatization with commercially available isotope variants of 2-aminobenzoic acid or aniline and analysis by LC- and CE-mass spectrometry. Quantitative information is attained from the extracted ion chromatogram/electropherogram ratios generated from the light and heavy isotope clusters.

  2. Role enactment of facilitation in primary care

    DEFF Research Database (Denmark)

    Due, Tina Drud; Thorsen, Thorkil; Waldorff, Frans Boch

    2017-01-01

    facilitation visits in 13 practice settings and had interviews and focus groups with facilitators. We applied an explorative approach in data collection and analysis, and conducted an inductive thematic analysis. RESULTS: The facilitators mainly enacted four facilitator roles: teacher, super user, peer...

  3. Role enactment of facilitation in primary care

    DEFF Research Database (Denmark)

    Due, Tina Drud; Thorsen, Thorkil; Waldorff, Frans Boch

    2017-01-01

    facilitation visits in 13 practice settings and had interviews and focus groups with facilitators. We applied an explorative approach in data collection and analysis, and conducted an inductive thematic analysis. Results: The facilitators mainly enacted four facilitator roles: teacher, super user, peer...

  4. Quantitative analysis of myocardial tissue with digital autofluorescence microscopy

    DEFF Research Database (Denmark)

    Jensen, Thomas; Holten-Rossing, Henrik; Svendsen, Ida M H

    2016-01-01

    to that of hematoxylin and eosin staining in conventional pathology. This study presents an automated fluorescence-based microscopy approach providing highly detailed morphological data from unstained microsections. This data may provide a basic histological starting point from which further digital analysis including...... staining may benefit. METHODS: This study explores the inherent tissue fluorescence, also known as autofluorescence, as a mean to quantitate cardiac tissue components in histological microsections. Data acquisition using a commercially available whole slide scanner and an image-based quantitation algorithm......BACKGROUND: The opportunity offered by whole slide scanners of automated histological analysis implies an ever increasing importance of digital pathology. To go beyond the importance of conventional pathology, however, digital pathology may need a basic histological starting point similar...

  5. Genetic toxicology at the crossroads-from qualitative hazard evaluation to quantitative risk assessment.

    Science.gov (United States)

    White, Paul A; Johnson, George E

    2016-05-01

    Applied genetic toxicology is undergoing a transition from qualitative hazard identification to quantitative dose-response analysis and risk assessment. To facilitate this change, the Health and Environmental Sciences Institute (HESI) Genetic Toxicology Technical Committee (GTTC) sponsored a workshop held in Lancaster, UK on July 10-11, 2014. The event included invited speakers from several institutions and the contents was divided into three themes-1: Point-of-departure Metrics for Quantitative Dose-Response Analysis in Genetic Toxicology; 2: Measurement and Estimation of Exposures for Better Extrapolation to Humans and 3: The Use of Quantitative Approaches in Genetic Toxicology for human health risk assessment (HHRA). A host of pertinent issues were discussed relating to the use of in vitro and in vivo dose-response data, the development of methods for in vitro to in vivo extrapolation and approaches to use in vivo dose-response data to determine human exposure limits for regulatory evaluations and decision-making. This Special Issue, which was inspired by the workshop, contains a series of papers that collectively address topics related to the aforementioned themes. The Issue includes contributions that collectively evaluate, describe and discuss in silico, in vitro, in vivo and statistical approaches that are facilitating the shift from qualitative hazard evaluation to quantitative risk assessment. The use and application of the benchmark dose approach was a central theme in many of the workshop presentations and discussions, and the Special Issue includes several contributions that outline novel applications for the analysis and interpretation of genetic toxicity data. Although the contents of the Special Issue constitutes an important step towards the adoption of quantitative methods for regulatory assessment of genetic toxicity, formal acceptance of quantitative methods for HHRA and regulatory decision-making will require consensus regarding the

  6. Quantitative analysis of target components by comprehensive two-dimensional gas chromatography

    NARCIS (Netherlands)

    Mispelaar, V.G. van; Tas, A.C.; Smilde, A.K.; Schoenmakers, P.J.; Asten, A.C. van

    2003-01-01

    Quantitative analysis using comprehensive two-dimensional (2D) gas chromatography (GC) is still rarely reported. This is largely due to a lack of suitable software. The objective of the present study is to generate quantitative results from a large GC x GC data set, consisting of 32 chromatograms.

  7. Role of image analysis in quantitative characterisation of nuclear fuel materials

    International Nuclear Information System (INIS)

    Dubey, J.N.; Rao, T.S.; Pandey, V.D.; Majumdar, S.

    2005-01-01

    Image analysis is one of the important techniques, widely used for materials characterization. It provides the quantitative estimation of the microstructural features present in the material. This information is very much valuable for finding out the criteria for taking up the fuel for high burn up. Radiometallurgy Division has been carrying out development and fabrication of plutonium related fuels for different type of reactors viz. Purnima, Fast Breeder Test Reactor (FBTR), Prototype Fast Breeder Reactor (PFBR), Boiling Water Reactor (BWR), Advanced Heavy Water Reactor (AHWR), Pressurised Heavy Water Reactor (PHWR) and KAMINI Reactor. Image analysis has been carried out on microstructures of PHWR, AHWR, FBTR and KAMINI fuels. Samples were prepared as per standard ASTM metallographic procedure. Digital images of the microstructure of these specimens were obtained using CCD camera, attached to the optical microscope. These images are stores on computer and used for detection and analysis of features of interest with image analysis software. Quantitative image analysis technique has been standardised and used for finding put type of the porosity, its size, shape and distribution in the above sintered oxide and carbide fuels. This technique has also been used for quantitative estimation of different phases present in KAMINI fuel. Image analysis results have been summarised and presented in this paper. (author)

  8. Micro photometer's automation for quantitative spectrograph analysis

    International Nuclear Information System (INIS)

    Gutierrez E, C.Y.A.

    1996-01-01

    A Microphotometer is used to increase the sharpness of dark spectral lines. Analyzing these lines one sample content and its concentration could be determined and the analysis is known as Quantitative Spectrographic Analysis. The Quantitative Spectrographic Analysis is carried out in 3 steps, as follows. 1. Emulsion calibration. This consists of gauging a photographic emulsion, to determine the intensity variations in terms of the incident radiation. For the procedure of emulsion calibration an adjustment with square minimum to the data obtained is applied to obtain a graph. It is possible to determine the density of dark spectral line against the incident light intensity shown by the microphotometer. 2. Working curves. The values of known concentration of an element against incident light intensity are plotted. Since the sample contains several elements, it is necessary to find a work curve for each one of them. 3. Analytical results. The calibration curve and working curves are compared and the concentration of the studied element is determined. The automatic data acquisition, calculation and obtaining of resulting, is done by means of a computer (PC) and a computer program. The conditioning signal circuits have the function of delivering TTL levels (Transistor Transistor Logic) to make the communication between the microphotometer and the computer possible. Data calculation is done using a computer programm

  9. [Rapid analysis of suppositories by quantitative 1H NMR spectroscopy].

    Science.gov (United States)

    Abramovich, R A; Kovaleva, S A; Goriainov, S V; Vorob'ev, A N; Kalabin, G A

    2012-01-01

    Rapid analysis of suppositories with ibuprofen and arbidol by quantitative 1H NMR spectroscopy was performed. Optimal conditions for the analysis were developed. The results are useful for design of rapid methods for quality control of suppositories with different components

  10. Quantitative EDXS analysis of organic materials using the ζ-factor method

    International Nuclear Information System (INIS)

    Fladischer, Stefanie; Grogger, Werner

    2014-01-01

    In this study we successfully applied the ζ-factor method to perform quantitative X-ray analysis of organic thin films consisting of light elements. With its ability to intrinsically correct for X-ray absorption, this method significantly improved the quality of the quantification as well as the accuracy of the results compared to conventional techniques in particular regarding the quantification of light elements. We describe in detail the process of determining sensitivity factors (ζ-factors) using a single standard specimen and the involved parameter optimization for the estimation of ζ-factors for elements not contained in the standard. The ζ-factor method was then applied to perform quantitative analysis of organic semiconducting materials frequently used in organic electronics. Finally, the results were verified and discussed concerning validity and accuracy. - Highlights: • The ζ-factor method is used for quantitative EDXS analysis of light elements. • We describe the process of determining ζ-factors from a single standard in detail. • Organic semiconducting materials are successfully quantified

  11. Quantitative analysis by computer controlled X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Balasubramanian, T.V.; Angelo, P.C.

    1981-01-01

    X-ray fluorescence spectroscopy has become a widely accepted method in the metallurgical field for analysis of both minor and major elements. As encountered in many other analytical techniques, the problem of matrix effect generally known as the interelemental effects is to be dealt with effectively in order to make the analysis accurate. There are several methods by which the effects of matrix on the analyte are minimised or corrected for and the mathematical correction is one among them. In this method the characteristic secondary X-ray intensities are measured from standard samples and correction coefficients. If any, for interelemental effects are evaluated by mathematical calculations. This paper describes attempts to evaluate the correction coefficients for interelemental effects by multiple linear regression programmes using a computer for the quantitative analysis of stainless steel and a nickel base cast alloy. The quantitative results obtained using this method for a standard stainless steel sample are compared with the given certified values. (author)

  12. A quantitative method for Failure Mode and Effects Analysis

    NARCIS (Netherlands)

    Braaksma, Anne Johannes Jan; Meesters, A.J.; Klingenberg, W.; Hicks, C.

    2012-01-01

    Failure Mode and Effects Analysis (FMEA) is commonly used for designing maintenance routines by analysing potential failures, predicting their effect and facilitating preventive action. It is used to make decisions on operational and capital expenditure. The literature has reported that despite its

  13. PIQMIe: A web server for semi-quantitative proteomics data management and analysis

    NARCIS (Netherlands)

    A. Kuzniar (Arnold); R. Kanaar (Roland)

    2014-01-01

    textabstractWe present the Proteomics Identifications and Quantitations Data Management and Integration Service or PIQMIe that aids in reliable and scalable data management, analysis and visualization of semi-quantitative mass spectrometry based proteomics experiments. PIQMIe readily integrates

  14. Machine learning-based quantitative texture analysis of CT images of small renal masses: Differentiation of angiomyolipoma without visible fat from renal cell carcinoma.

    Science.gov (United States)

    Feng, Zhichao; Rong, Pengfei; Cao, Peng; Zhou, Qingyu; Zhu, Wenwei; Yan, Zhimin; Liu, Qianyun; Wang, Wei

    2018-04-01

    To evaluate the diagnostic performance of machine-learning based quantitative texture analysis of CT images to differentiate small (≤ 4 cm) angiomyolipoma without visible fat (AMLwvf) from renal cell carcinoma (RCC). This single-institutional retrospective study included 58 patients with pathologically proven small renal mass (17 in AMLwvf and 41 in RCC groups). Texture features were extracted from the largest possible tumorous regions of interest (ROIs) by manual segmentation in preoperative three-phase CT images. Interobserver reliability and the Mann-Whitney U test were applied to select features preliminarily. Then support vector machine with recursive feature elimination (SVM-RFE) and synthetic minority oversampling technique (SMOTE) were adopted to establish discriminative classifiers, and the performance of classifiers was assessed. Of the 42 extracted features, 16 candidate features showed significant intergroup differences (P Machine learning analysis of CT texture features can facilitate the accurate differentiation of small AMLwvf from RCC. • Although conventional CT is useful for diagnosis of SRMs, it has limitations. • Machine-learning based CT texture analysis facilitate differentiation of small AMLwvf from RCC. • The highest accuracy of SVM-RFE+SMOTE classifier reached 93.9 %. • Texture analysis combined with machine-learning methods might spare unnecessary surgery for AMLwvf.

  15. Issues in Quantitative Analysis of Ultraviolet Imager (UV) Data: Airglow

    Science.gov (United States)

    Germany, G. A.; Richards, P. G.; Spann, J. F.; Brittnacher, M. J.; Parks, G. K.

    1999-01-01

    The GGS Ultraviolet Imager (UVI) has proven to be especially valuable in correlative substorm, auroral morphology, and extended statistical studies of the auroral regions. Such studies are based on knowledge of the location, spatial, and temporal behavior of auroral emissions. More quantitative studies, based on absolute radiometric intensities from UVI images, require a more intimate knowledge of the instrument behavior and data processing requirements and are inherently more difficult than studies based on relative knowledge of the oval location. In this study, UVI airglow observations are analyzed and compared with model predictions to illustrate issues that arise in quantitative analysis of UVI images. These issues include instrument calibration, long term changes in sensitivity, and imager flat field response as well as proper background correction. Airglow emissions are chosen for this study because of their relatively straightforward modeling requirements and because of their implications for thermospheric compositional studies. The analysis issues discussed here, however, are identical to those faced in quantitative auroral studies.

  16. Critical appraisal of semi-quantitative analysis of 2-deoxyglucose autoradiograms

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, P T; McCulloch, J [Glasgow Univ. (UK)

    1983-06-13

    Semi-quantitative analysis (e.g. optical density ratios) of (/sup 14/C)2-deoxyglucose autoradiograms is widely used in neuroscience research. The authors demonstrate that a fixed ratio of /sup 14/C-concentrations in the CNS does not yield a constant optical density ratio but is dependent upon the exposure time in the preparation of the autoradiograms and the absolute amounts of /sup 14/C from which the concentration ratio is derived. The failure of a fixed glucose utilization ratio to result in a constant optical density ratio represents a major interpretative difficulty in investigations where only semi-quantitative analysis of (/sup 14/C)2-deoxyglucose autoradiograms is undertaken.

  17. Quantitative-genetic analysis of wing form and bilateral asymmetry ...

    Indian Academy of Sciences (India)

    Unknown

    lines; Procrustes analysis; wing shape; wing size. ... Models of stochastic gene expression pre- dict that intrinsic noise ... Quantitative parameters of wing size and shape asymmetries ..... the residuals of a regression on centroid size produced.

  18. Quantitative Analysis of Complex Tropical Forest Stands: A Review ...

    African Journals Online (AJOL)

    FIRST LADY

    The importance of data analysis in quantitative assessment of natural resources .... Data collection design is an important process in complex forest statistical ... Ideally, the sample size should be equal among groups and sufficiently large.

  19. Transportation and quantitative analysis of socio-economic development of relations

    Science.gov (United States)

    Chen, Yun

    2017-12-01

    Transportation has a close relationship with socio-economic. This article selects the indicators which can measure the development of transportation and socio-economic, using the method of correlation analysis, regression analysis, intensity of transportation analysis and transport elastic analysis, to analyze the relationship between them quantitatively, so that it has the fact guiding sense in the national development planning for the future.

  20. Quantitative high-resolution genomic analysis of single cancer cells.

    Science.gov (United States)

    Hannemann, Juliane; Meyer-Staeckling, Sönke; Kemming, Dirk; Alpers, Iris; Joosse, Simon A; Pospisil, Heike; Kurtz, Stefan; Görndt, Jennifer; Püschel, Klaus; Riethdorf, Sabine; Pantel, Klaus; Brandt, Burkhard

    2011-01-01

    During cancer progression, specific genomic aberrations arise that can determine the scope of the disease and can be used as predictive or prognostic markers. The detection of specific gene amplifications or deletions in single blood-borne or disseminated tumour cells that may give rise to the development of metastases is of great clinical interest but technically challenging. In this study, we present a method for quantitative high-resolution genomic analysis of single cells. Cells were isolated under permanent microscopic control followed by high-fidelity whole genome amplification and subsequent analyses by fine tiling array-CGH and qPCR. The assay was applied to single breast cancer cells to analyze the chromosomal region centred by the therapeutical relevant EGFR gene. This method allows precise quantitative analysis of copy number variations in single cell diagnostics.

  1. Quantitative Proteomic Analysis of Sulfolobus solfataricus Membrane Proteins

    NARCIS (Netherlands)

    Pham, T.K.; Sierocinski, P.; Oost, van der J.; Wright, P.C.

    2010-01-01

    A quantitative proteomic analysis of the membrane of the archaeon Sulfolobus solfataricus P2 using iTRAQ was successfully demonstrated in this technical note. The estimated number of membrane proteins of this organism is 883 (predicted based on Gravy score), corresponding to 30 % of the total

  2. Quantitative X-ray analysis of biological fluids: the microdroplet technique

    International Nuclear Information System (INIS)

    Roinel, N.

    1988-01-01

    X-ray microanalysis can be used to quantitatively determine the elemental composition of microvolumes of biological fluids. This article describes the various steps in preparation of microdroplets for analysis: The manufacturing of micropipettes, the preparation of the specimen support, the deposition of droplets on the support, shock-freezing, and lyophilization. Examples of common artifacts (incomplete rehydration prior to freezing or partial rehydration after lyophilization) are demonstrated. Analysis can be carried out either by wavelength-dispersive analysis, which is the most sensitive method, or by energy-dispersive analysis, which is more commonly available. The minimum detectable concentration is 0.05 mmol.liter-1 for 0.1-nl samples analyzed by wavelength-dispersive spectrometry and 0.5-1 mmol.liter-1 for samples analyzed by energy-dispersive spectrometry. A major problem, especially in wavelength-dispersive analysis, where high beam currents are used, is radiation damage to the specimen; in particular chloride (but also other elements) can be lost. Quantitative analysis requires the use of standard solutions with elemental concentration in the same range as those present in the specimen

  3. Method of quantitative x-ray diffractometric analysis of Ta-Ta2C system

    International Nuclear Information System (INIS)

    Gavrish, A.A.; Glazunov, M.P.; Korolev, Yu.M.; Spitsyn, V.I.; Fedoseev, G.K.

    1976-01-01

    The syste86 Ta-Ta 2 C has beemonsidered because of specific features of diffraction patterns of the components, namely, overlapping of the most intensive reflexes of both phases. The method of standard binary system has been used for quantitative analysis. Because of overlapping of the intensive reflexes dsub(1/01)=2.36(Ta 2 C) and dsub(110)=2.33(Ta), the other, most intensive, reflexes have been used for quantitative determination of Ta 2 C and Ta: dsub(103)=1.404 A for tantalum subcarbide and dsub(211)=1.35A for tantalum. Besides, the TaTa 2 C phases have been determined quantitatively with the use of another pair of reflexes: dsub(102)=1.82 A for Ta 2 C and dsub(200)=1.65 A for tantalum. The agreement between the results obtained while performing the quantitative phase analysis is good. To increase reliability and accuracy of the quantitative determination of Ta and Ta 2 C, it is expedient to carry out the analysis with the use of two above-mentioned pairs of reflexes located in different regions of the diffraction spectrum. Thus, the procedure of quantitative analysis of Ta and Ta 2 C in different ratios has been developed taking into account the specific features of the diffraction patterns of these components as well as the ability of Ta 2 C to texture in the process of preparation

  4. A Quantitative Analysis of the Behavioral Checklist of the Movement ABC Motor Test

    Science.gov (United States)

    Ruiz, Luis Miguel; Gomez, Marta; Graupera, Jose Luis; Gutierrez, Melchor; Linaza, Jose Luis

    2007-01-01

    The fifth section of the Henderson and Sugden's Movement ABC Checklist is part of the general Checklist that accompanies The Movement ABC Battery. The authors maintain that the analysis of this section must be mainly qualitative instead of quantitative. The main objective of this study was to employ a quantitative analysis of this behavioural…

  5. Quantitative assessment of in-solution digestion efficiency identifies optimal protocols for unbiased protein analysis

    DEFF Research Database (Denmark)

    Leon, Ileana R; Schwämmle, Veit; Jensen, Ole N

    2013-01-01

    a combination of qualitative and quantitative LC-MS/MS methods and statistical data analysis. In contrast to previous studies we employed both standard qualitative as well as data-independent quantitative workflows to systematically assess trypsin digestion efficiency and bias using mitochondrial protein...... conditions (buffer, RapiGest, deoxycholate, urea), and two methods for removal of detergents prior to analysis of peptides (acid precipitation or phase separation with ethyl acetate). Our data-independent quantitative LC-MS/MS workflow quantified over 3700 distinct peptides with 96% completeness between all...... protocols and replicates, with an average 40% protein sequence coverage and an average of 11 peptides identified per protein. Systematic quantitative and statistical analysis of physicochemical parameters demonstrated that deoxycholate-assisted in-solution digestion combined with phase transfer allows...

  6. Chemical Fingerprint Analysis and Quantitative Analysis of Rosa rugosa by UPLC-DAD

    Directory of Open Access Journals (Sweden)

    Sanawar Mansur

    2016-12-01

    Full Text Available A method based on ultra performance liquid chromatography with a diode array detector (UPLC-DAD was developed for quantitative analysis of five active compounds and chemical fingerprint analysis of Rosa rugosa. Ten batches of R. rugosa collected from different plantations in the Xinjiang region of China were used to establish the fingerprint. The feasibility and advantages of the used UPLC fingerprint were verified for its similarity evaluation by systematically comparing chromatograms with professional analytical software recommended by State Food and Drug Administration (SFDA of China. In quantitative analysis, the five compounds showed good regression (R2 = 0.9995 within the test ranges, and the recovery of the method was in the range of 94.2%–103.8%. The similarities of liquid chromatography fingerprints of 10 batches of R. rugosa were more than 0.981. The developed UPLC fingerprint method is simple, reliable, and validated for the quality control and identification of R. rugosa. Additionally, simultaneous quantification of five major bioactive ingredients in the R. rugosa samples was conducted to interpret the consistency of the quality test. The results indicated that the UPLC fingerprint, as a characteristic distinguishing method combining similarity evaluation and quantification analysis, can be successfully used to assess the quality and to identify the authenticity of R. rugosa.

  7. Phase analysis in duplex stainless steel: comparison of EBSD and quantitative metallography methods

    International Nuclear Information System (INIS)

    Michalska, J; Chmiela, B

    2014-01-01

    The purpose of the research was to work out the qualitative and quantitative analysis of phases in DSS in as-received state and after thermal aging. For quantitative purposes, SEM observations, EDS analyses and electron backscattered diffraction (EBSD) methods were employed. Qualitative analysis of phases was performed by two methods: EBSD and classical quantitative metallography. A juxtaposition of different etchants for the revealing of microstructure and brief review of sample preparation methods for EBSD studies were presented. Different ways of sample preparation were tested and based on these results a detailed methodology of DSS phase analysis was developed including: surface finishing, selective etching methods and image acquisition. The advantages and disadvantages of applied methods were pointed out and compared the accuracy of the analysis phase performed by both methods

  8. Comparative study of standard space and real space analysis of quantitative MR brain data.

    Science.gov (United States)

    Aribisala, Benjamin S; He, Jiabao; Blamire, Andrew M

    2011-06-01

    To compare the robustness of region of interest (ROI) analysis of magnetic resonance imaging (MRI) brain data in real space with analysis in standard space and to test the hypothesis that standard space image analysis introduces more partial volume effect errors compared to analysis of the same dataset in real space. Twenty healthy adults with no history or evidence of neurological diseases were recruited; high-resolution T(1)-weighted, quantitative T(1), and B(0) field-map measurements were collected. Algorithms were implemented to perform analysis in real and standard space and used to apply a simple standard ROI template to quantitative T(1) datasets. Regional relaxation values and histograms for both gray and white matter tissues classes were then extracted and compared. Regional mean T(1) values for both gray and white matter were significantly lower using real space compared to standard space analysis. Additionally, regional T(1) histograms were more compact in real space, with smaller right-sided tails indicating lower partial volume errors compared to standard space analysis. Standard space analysis of quantitative MRI brain data introduces more partial volume effect errors biasing the analysis of quantitative data compared to analysis of the same dataset in real space. Copyright © 2011 Wiley-Liss, Inc.

  9. Statistical shape analysis using 3D Poisson equation--A quantitatively validated approach.

    Science.gov (United States)

    Gao, Yi; Bouix, Sylvain

    2016-05-01

    Statistical shape analysis has been an important area of research with applications in biology, anatomy, neuroscience, agriculture, paleontology, etc. Unfortunately, the proposed methods are rarely quantitatively evaluated, and as shown in recent studies, when they are evaluated, significant discrepancies exist in their outputs. In this work, we concentrate on the problem of finding the consistent location of deformation between two population of shapes. We propose a new shape analysis algorithm along with a framework to perform a quantitative evaluation of its performance. Specifically, the algorithm constructs a Signed Poisson Map (SPoM) by solving two Poisson equations on the volumetric shapes of arbitrary topology, and statistical analysis is then carried out on the SPoMs. The method is quantitatively evaluated on synthetic shapes and applied on real shape data sets in brain structures. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Quantitative analysis of background parenchymal enhancement in whole breast on MRI: Influence of menstrual cycle and comparison with a qualitative analysis.

    Science.gov (United States)

    Jung, Yongsik; Jeong, Seong Kyun; Kang, Doo Kyoung; Moon, Yeorae; Kim, Tae Hee

    2018-06-01

    We quantitatively analyzed background parenchymal enhancement (BPE) in whole breast according to menstrual cycle and compared it with a qualitative analysis method. A data set of breast magnetic resonance imaging (MRI) from 273 breast cancer patients was used. For quantitative analysis, we used semiautomated in-house software with MATLAB. From each voxel of whole breast, the software calculated BPE using following equation: [(signal intensity [SI] at 1 min 30 s after contrast injection - baseline SI)/baseline SI] × 100%. In total, 53 patients had minimal, 108 mild, 87 moderate, and 25 marked BPE. On quantitative analysis, mean BPE values were 33.1% in the minimal, 42.1% in the mild, 59.1% in the moderate, and 81.9% in the marked BPE group showing significant difference (p = .009 for minimal vs. mild, p quantitative BPE (r = 0.63, p Quantitative analysis of BPE correlated well with the qualitative BPE grade. Quantitative BPE values were lowest in the second week and highest in the fourth week. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Towards quantitative laser-induced breakdown spectroscopy analysis of soil samples

    International Nuclear Information System (INIS)

    Bousquet, B.; Sirven, J.-B.; Canioni, L.

    2007-01-01

    A quantitative analysis of chromium in soil samples is presented. Different emission lines related to chromium are studied in order to select the best one for quantitative features. Important matrix effects are demonstrated from one soil to the other, preventing any prediction of concentration in different soils on the basis of a univariate calibration curve. Finally, a classification of the LIBS data based on a series of Principal Component Analyses (PCA) is applied to a reduced dataset of selected spectral lines related to the major chemical elements in the soils. LIBS data of heterogeneous soils appear to be widely dispersed, which leads to a reconsideration of the sampling step in the analysis process

  12. Quantitative high-resolution genomic analysis of single cancer cells.

    Directory of Open Access Journals (Sweden)

    Juliane Hannemann

    Full Text Available During cancer progression, specific genomic aberrations arise that can determine the scope of the disease and can be used as predictive or prognostic markers. The detection of specific gene amplifications or deletions in single blood-borne or disseminated tumour cells that may give rise to the development of metastases is of great clinical interest but technically challenging. In this study, we present a method for quantitative high-resolution genomic analysis of single cells. Cells were isolated under permanent microscopic control followed by high-fidelity whole genome amplification and subsequent analyses by fine tiling array-CGH and qPCR. The assay was applied to single breast cancer cells to analyze the chromosomal region centred by the therapeutical relevant EGFR gene. This method allows precise quantitative analysis of copy number variations in single cell diagnostics.

  13. Digital image analysis

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Vainer, Ben; Steiniche, Torben

    2012-01-01

    Digital image analysis (DIA) is increasingly implemented in histopathological research to facilitate truly quantitative measurements, decrease inter-observer variation and reduce hands-on time. Originally, efforts were made to enable DIA to reproduce manually obtained results on histological slides...... reproducibility, application of stereology-based quantitative measurements, time consumption, optimization of histological slides, regions of interest selection and recent developments in staining and imaging techniques....

  14. Quantitative risk analysis as a basis for emergency planning

    Energy Technology Data Exchange (ETDEWEB)

    Yogui, Regiane Tiemi Teruya [Bureau Veritas do Brasil, Rio de Janeiro, RJ (Brazil); Macedo, Eduardo Soares de [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)

    2009-07-01

    Several environmental accidents happened in Brazil and in the world during the 70's and 80's. This strongly motivated the preparation for emergencies in the chemical and petrochemical industries. Environmental accidents affect the environment and the communities that are neighbor to the industrial facilities. The present study aims at subsidizing and providing orientation to develop Emergency Planning from the data obtained on Quantitative Risk Analysis, elaborated according to the Technical Standard P4.261/03 from CETESB (Sao Paulo Environmental Agency). It was observed, during the development of the research, that the data generated on these studies need a complementation and a deeper analysis, so that it is possible to use them on the Emergency Plans. The main issues that were analyzed and discussed on this study were the reevaluation of hazard identification for the emergency plans, the consequences and vulnerability analysis for the response planning, the risk communication, and the preparation to respond to the emergencies of the communities exposed to manageable risks. As a result, the study intends to improve the interpretation and use of the data deriving from the Quantitative Risk Analysis to develop the emergency plans. (author)

  15. A Strategy for Identifying Quantitative Trait Genes Using Gene Expression Analysis and Causal Analysis

    Directory of Open Access Journals (Sweden)

    Akira Ishikawa

    2017-11-01

    Full Text Available Large numbers of quantitative trait loci (QTL affecting complex diseases and other quantitative traits have been reported in humans and model animals. However, the genetic architecture of these traits remains elusive due to the difficulty in identifying causal quantitative trait genes (QTGs for common QTL with relatively small phenotypic effects. A traditional strategy based on techniques such as positional cloning does not always enable identification of a single candidate gene for a QTL of interest because it is difficult to narrow down a target genomic interval of the QTL to a very small interval harboring only one gene. A combination of gene expression analysis and statistical causal analysis can greatly reduce the number of candidate genes. This integrated approach provides causal evidence that one of the candidate genes is a putative QTG for the QTL. Using this approach, I have recently succeeded in identifying a single putative QTG for resistance to obesity in mice. Here, I outline the integration approach and discuss its usefulness using my studies as an example.

  16. A Strategy for Identifying Quantitative Trait Genes Using Gene Expression Analysis and Causal Analysis.

    Science.gov (United States)

    Ishikawa, Akira

    2017-11-27

    Large numbers of quantitative trait loci (QTL) affecting complex diseases and other quantitative traits have been reported in humans and model animals. However, the genetic architecture of these traits remains elusive due to the difficulty in identifying causal quantitative trait genes (QTGs) for common QTL with relatively small phenotypic effects. A traditional strategy based on techniques such as positional cloning does not always enable identification of a single candidate gene for a QTL of interest because it is difficult to narrow down a target genomic interval of the QTL to a very small interval harboring only one gene. A combination of gene expression analysis and statistical causal analysis can greatly reduce the number of candidate genes. This integrated approach provides causal evidence that one of the candidate genes is a putative QTG for the QTL. Using this approach, I have recently succeeded in identifying a single putative QTG for resistance to obesity in mice. Here, I outline the integration approach and discuss its usefulness using my studies as an example.

  17. Quantitative analysis of patient-specific dosimetric IMRT verification

    International Nuclear Information System (INIS)

    Budgell, G J; Perrin, B A; Mott, J H L; Fairfoul, J; Mackay, R I

    2005-01-01

    Patient-specific dosimetric verification methods for IMRT treatments are variable, time-consuming and frequently qualitative, preventing evidence-based reduction in the amount of verification performed. This paper addresses some of these issues by applying a quantitative analysis parameter to the dosimetric verification procedure. Film measurements in different planes were acquired for a series of ten IMRT prostate patients, analysed using the quantitative parameter, and compared to determine the most suitable verification plane. Film and ion chamber verification results for 61 patients were analysed to determine long-term accuracy, reproducibility and stability of the planning and delivery system. The reproducibility of the measurement and analysis system was also studied. The results show that verification results are strongly dependent on the plane chosen, with the coronal plane particularly insensitive to delivery error. Unexpectedly, no correlation could be found between the levels of error in different verification planes. Longer term verification results showed consistent patterns which suggest that the amount of patient-specific verification can be safely reduced, provided proper caution is exercised: an evidence-based model for such reduction is proposed. It is concluded that dose/distance to agreement (e.g., 3%/3 mm) should be used as a criterion of acceptability. Quantitative parameters calculated for a given criterion of acceptability should be adopted in conjunction with displays that show where discrepancies occur. Planning and delivery systems which cannot meet the required standards of accuracy, reproducibility and stability to reduce verification will not be accepted by the radiotherapy community

  18. Fluorescent foci quantitation for high-throughput analysis

    Directory of Open Access Journals (Sweden)

    Elena Ledesma-Fernández

    2015-06-01

    Full Text Available A number of cellular proteins localize to discrete foci within cells, for example DNA repair proteins, microtubule organizing centers, P bodies or kinetochores. It is often possible to measure the fluorescence emission from tagged proteins within these foci as a surrogate for the concentration of that specific protein. We wished to develop tools that would allow quantitation of fluorescence foci intensities in high-throughput studies. As proof of principle we have examined the kinetochore, a large multi-subunit complex that is critical for the accurate segregation of chromosomes during cell division. Kinetochore perturbations lead to aneuploidy, which is a hallmark of cancer cells. Hence, understanding kinetochore homeostasis and regulation are important for a global understanding of cell division and genome integrity. The 16 budding yeast kinetochores colocalize within the nucleus to form a single focus. Here we have created a set of freely-available tools to allow high-throughput quantitation of kinetochore foci fluorescence. We use this ‘FociQuant’ tool to compare methods of kinetochore quantitation and we show proof of principle that FociQuant can be used to identify changes in kinetochore protein levels in a mutant that affects kinetochore function. This analysis can be applied to any protein that forms discrete foci in cells.

  19. A simple approach to quantitative analysis using three-dimensional spectra based on selected Zernike moments.

    Science.gov (United States)

    Zhai, Hong Lin; Zhai, Yue Yuan; Li, Pei Zhen; Tian, Yue Li

    2013-01-21

    A very simple approach to quantitative analysis is proposed based on the technology of digital image processing using three-dimensional (3D) spectra obtained by high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD). As the region-based shape features of a grayscale image, Zernike moments with inherently invariance property were employed to establish the linear quantitative models. This approach was applied to the quantitative analysis of three compounds in mixed samples using 3D HPLC-DAD spectra, and three linear models were obtained, respectively. The correlation coefficients (R(2)) for training and test sets were more than 0.999, and the statistical parameters and strict validation supported the reliability of established models. The analytical results suggest that the Zernike moment selected by stepwise regression can be used in the quantitative analysis of target compounds. Our study provides a new idea for quantitative analysis using 3D spectra, which can be extended to the analysis of other 3D spectra obtained by different methods or instruments.

  20. Single particle transfer for quantitative analysis with total-reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu; Watanabe, Kazuo

    2006-01-01

    The technique of single particle transfer was applied to quantitative analysis with total-reflection X-ray fluorescence (TXRF) spectrometry. The technique was evaluated by performing quantitative analysis of individual Cu particles with diameters between 3.9 and 13.2 μm. The direct quantitative analysis of the Cu particle transferred onto a Si carrier gave a discrepancy between measured and calculated Cu amounts due to the absorption effects of incident and fluorescent X-rays within the particle. By the correction for the absorption effects, the Cu amounts in individual particles could be determined with the deviation within 10.5%. When the Cu particles were dissolved with HNO 3 solution prior to the TXRF analysis, the deviation was improved to be within 3.8%. In this case, no correction for the absorption effects was needed for quantification

  1. Quantitative analysis of thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kanemoto, Nariaki; Hoer, G.; Johost, S.; Maul, F.-D.; Standke, R.

    1981-01-01

    The method of quantitative analysis of thallium-201 myocardial scintigraphy using computer assisted technique was described. Calculated indices are washout factor, vitality index and redistribution factor. Washout factor is the ratio of counts at certain period of time after exercise and immediately after exercise. This value is neccessary for the evaluation of redistribution to the ischemic areas in serial imagings to correct the Tl-201 washout from the myocardium under the assumption that the washout is constant in the whole myocardium. Vitality index is the ratio between the Tl-201 uptake in the region of interest and that of the maximum. Redistribution factor is the ratio of the redistribution in the region of interest in serial imagings after exercise to that of immediately after exercise. Four examples of exercise Tl-201 myocardial scintigrams and the quantitative analyses before and after the percutaneous transluminal coronary angioplasty were presented. (author)

  2. Quantitative Model for Economic Analyses of Information Security Investment in an Enterprise Information System

    Directory of Open Access Journals (Sweden)

    Bojanc Rok

    2012-11-01

    Full Text Available The paper presents a mathematical model for the optimal security-technology investment evaluation and decision-making processes based on the quantitative analysis of security risks and digital asset assessments in an enterprise. The model makes use of the quantitative analysis of different security measures that counteract individual risks by identifying the information system processes in an enterprise and the potential threats. The model comprises the target security levels for all identified business processes and the probability of a security accident together with the possible loss the enterprise may suffer. The selection of security technology is based on the efficiency of selected security measures. Economic metrics are applied for the efficiency assessment and comparative analysis of different protection technologies. Unlike the existing models for evaluation of the security investment, the proposed model allows direct comparison and quantitative assessment of different security measures. The model allows deep analyses and computations providing quantitative assessments of different options for investments, which translate into recommendations facilitating the selection of the best solution and the decision-making thereof. The model was tested using empirical examples with data from real business environment.

  3. Quantitative pulsed eddy current analysis

    International Nuclear Information System (INIS)

    Morris, R.A.

    1975-01-01

    The potential of pulsed eddy current testing for furnishing more information than conventional single-frequency eddy current methods has been known for some time. However, a fundamental problem has been analyzing the pulse shape with sufficient precision to produce accurate quantitative results. Accordingly, the primary goal of this investigation was to: demonstrate ways of digitizing the short pulses encountered in PEC testing, and to develop empirical analysis techniques that would predict some of the parameters (e.g., depth) of simple types of defect. This report describes a digitizing technique using a computer and either a conventional nuclear ADC or a fast transient analyzer; the computer software used to collect and analyze pulses; and some of the results obtained. (U.S.)

  4. Quantitative surface analysis using deuteron-induced nuclear reactions

    International Nuclear Information System (INIS)

    Afarideh, Hossein

    1991-01-01

    The nuclear reaction analysis (NRA) technique consists of looking at the energies of the reaction products which uniquely define the particular elements present in the sample and it analysis the yield/energy distribution to reveal depth profiles. A summary of the basic features of the nuclear reaction analysis technique is given, in particular emphasis is placed on quantitative light element determination using (d,p) and (d,alpha) reactions. The experimental apparatus is also described. Finally a set of (d,p) spectra for the elements Z=3 to Z=17 using 2 MeV incident deutrons is included together with example of more applications of the (d,alpha) spectra. (author)

  5. Strategies for quantitation of phosphoproteomic data

    DEFF Research Database (Denmark)

    Palmisano, Giuseppe; Thingholm, Tine Engberg

    2010-01-01

    Recent developments in phosphoproteomic sample-preparation techniques and sensitive mass spectrometry instrumentation have led to large-scale identifications of phosphoproteins and phosphorylation sites from highly complex samples. This has facilitated the implementation of different quantitation...

  6. SWATH2stats: An R/Bioconductor Package to Process and Convert Quantitative SWATH-MS Proteomics Data for Downstream Analysis Tools.

    Science.gov (United States)

    Blattmann, Peter; Heusel, Moritz; Aebersold, Ruedi

    2016-01-01

    SWATH-MS is an acquisition and analysis technique of targeted proteomics that enables measuring several thousand proteins with high reproducibility and accuracy across many samples. OpenSWATH is popular open-source software for peptide identification and quantification from SWATH-MS data. For downstream statistical and quantitative analysis there exist different tools such as MSstats, mapDIA and aLFQ. However, the transfer of data from OpenSWATH to the downstream statistical tools is currently technically challenging. Here we introduce the R/Bioconductor package SWATH2stats, which allows convenient processing of the data into a format directly readable by the downstream analysis tools. In addition, SWATH2stats allows annotation, analyzing the variation and the reproducibility of the measurements, FDR estimation, and advanced filtering before submitting the processed data to downstream tools. These functionalities are important to quickly analyze the quality of the SWATH-MS data. Hence, SWATH2stats is a new open-source tool that summarizes several practical functionalities for analyzing, processing, and converting SWATH-MS data and thus facilitates the efficient analysis of large-scale SWATH/DIA datasets.

  7. Evaluation of shear wave elastography for differential diagnosis of breast lesions: A new qualitative analysis versus conventional quantitative analysis.

    Science.gov (United States)

    Ren, Wei-Wei; Li, Xiao-Long; Wang, Dan; Liu, Bo-Ji; Zhao, Chong-Ke; Xu, Hui-Xiong

    2018-04-13

    To evaluate a special kind of ultrasound (US) shear wave elastography for differential diagnosis of breast lesions, using a new qualitative analysis (i.e. the elasticity score in the travel time map) compared with conventional quantitative analysis. From June 2014 to July 2015, 266 pathologically proven breast lesions were enrolled in this study. The maximum, mean, median, minimum, and standard deviation of shear wave speed (SWS) values (m/s) were assessed. The elasticity score, a new qualitative feature, was evaluated in the travel time map. The area under the receiver operating characteristic (AUROC) curves were plotted to evaluate the diagnostic performance of both qualitative and quantitative analyses for differentiation of breast lesions. Among all quantitative parameters, SWS-max showed the highest AUROC (0.805; 95% CI: 0.752, 0.851) compared with SWS-mean (0.786; 95% CI:0.732, 0.834; P = 0.094), SWS-median (0.775; 95% CI:0.720, 0.824; P = 0.046), SWS-min (0.675; 95% CI:0.615, 0.731; P = 0.000), and SWS-SD (0.768; 95% CI:0.712, 0.817; P = 0.074). The AUROC of qualitative analysis in this study obtained the best diagnostic performance (0.871; 95% CI: 0.825, 0.909, compared with the best parameter of SWS-max in quantitative analysis, P = 0.011). The new qualitative analysis of shear wave travel time showed the superior diagnostic performance in the differentiation of breast lesions in comparison with conventional quantitative analysis.

  8. MCM - 2 and Ki - 67 as proliferation markers in renal cell carcinoma: A quantitative and semi - quantitative analysis.

    Science.gov (United States)

    Mehdi, Muhammad Zain; Nagi, Abdul Hanan; Naseem, Nadia

    2016-01-01

    Fuhrman nuclear grade is the most important histological parameter to predict prognosis in a patient of renal cell carcinoma (RCC). However, it suffers from inter-observer and intra-observer variation giving rise to need of a parameter that not only correlates with nuclear grade but is also objective and reproducible. Proliferation is the measure of aggressiveness of a tumour and it is strongly correlated with Fuhrman nuclear grade, clinical survival and recurrence in RCC. Ki-67 is conventionally used to assess proliferation. Mini-chromosome maintenance 2 (MCM-2) is a lesser known marker of proliferation and identifies a greater proliferation faction. This study was designed to assess the prognostic significance of MCM-2 by comparing it with Fuhrman nuclear grade and Ki-67. n=50 cases of various ages, stages, histological subtypes and grades of RCC were selected for this study. Immunohistochemical staining using Ki-67(MIB-1, Mouse monoclonal antibody, Dako) and MCM-2 (Mouse monoclonal antibody, Thermo) was performed on the paraffin embedded blocks in the department of Morbid anatomy and Histopathology, University of Health Sciences, Lahore. Labeling indices (LI) were determined by two pathologists independently using quantitative and semi-quantitative analysis. Statistical analysis was carried out using SPSS 20.0. Kruskall-Wallis test was used to determine a correlation of proliferation markers with grade, and Pearson's correlate was used to determine correlation between the two proliferation markers. Labeling index of MCM-2 (median=24.29%) was found to be much higher than Ki-67(median=13.05%). Both markers were significantly related with grade (p=0.00; Kruskall-Wallis test). LI of MCM-2 was found to correlate significantly with LI of Ki-67(r=0.0934;p=0.01 with Pearson's correlate). Results of semi-quantitative analysis correlated well with quantitative analysis. Both Ki-67 and MCM-2 are markers of proliferation which are closely linked to grade. Therefore, they

  9. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    Science.gov (United States)

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial

  10. A critical appraisal of semi-quantitative analysis of 2-deoxyglucose autoradiograms

    International Nuclear Information System (INIS)

    Kelly, P.T.; McCulloch, J.

    1983-01-01

    Semi-quantitative analysis (e.g. optical density ratios) of [ 14 C]2-deoxyglucose autoradiograms is widely used in neuroscience research. The authors demonstrate that a fixed ratio of 14 C-concentrations in the CNS does not yield a constant optical density ratio but is dependent upon the exposure time in the preparation of the autoradiograms and the absolute amounts of 14 C from which the concentration ratio is derived. The failure of a fixed glucose utilization ratio to result in a constant optical density ratio represents a major interpretative difficulty in investigations where only semi-quantitative analysis of [ 14 C]2-deoxyglucose autoradiograms is undertaken. (Auth.)

  11. Quantitative analysis of culture using millions of digitized books.

    Science.gov (United States)

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva Presser; Veres, Adrian; Gray, Matthew K; Pickett, Joseph P; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A; Aiden, Erez Lieberman

    2011-01-14

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of 'culturomics,' focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pursuit of fame, censorship, and historical epidemiology. Culturomics extends the boundaries of rigorous quantitative inquiry to a wide array of new phenomena spanning the social sciences and the humanities.

  12. Quantitative analysis of culture using millions of digitized books

    Science.gov (United States)

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva P.; Veres, Adrian; Gray, Matthew K.; Pickett, Joseph P.; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A.; Aiden, Erez Lieberman

    2011-01-01

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of ‘culturomics’, focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pursuit of fame, censorship, and historical epidemiology. ‘Culturomics’ extends the boundaries of rigorous quantitative inquiry to a wide array of new phenomena spanning the social sciences and the humanities. PMID:21163965

  13. Quantitative mass spectrometric analysis of glycoproteins combined with enrichment methods.

    Science.gov (United States)

    Ahn, Yeong Hee; Kim, Jin Young; Yoo, Jong Shin

    2015-01-01

    Mass spectrometry (MS) has been a core technology for high sensitive and high-throughput analysis of the enriched glycoproteome in aspects of quantitative assays as well as qualitative profiling of glycoproteins. Because it has been widely recognized that aberrant glycosylation in a glycoprotein may involve in progression of a certain disease, the development of efficient analysis tool for the aberrant glycoproteins is very important for deep understanding about pathological function of the glycoprotein and new biomarker development. This review first describes the protein glycosylation-targeting enrichment technologies mainly employing solid-phase extraction methods such as hydrizide-capturing, lectin-specific capturing, and affinity separation techniques based on porous graphitized carbon, hydrophilic interaction chromatography, or immobilized boronic acid. Second, MS-based quantitative analysis strategies coupled with the protein glycosylation-targeting enrichment technologies, by using a label-free MS, stable isotope-labeling, or targeted multiple reaction monitoring (MRM) MS, are summarized with recent published studies. © 2014 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.

  14. Quantitative analysis of macro-ARG using IP system

    International Nuclear Information System (INIS)

    Nakajima, Eiichi; Kawai, Kenji; Furuta, Yoshitake

    1997-01-01

    Recent progress in imaging plate (IP) system allow us to analyze autoradiographic images quantitatively. In the 'whole-body autoradiography', a method clarify the distribution of radioisotope or labeled compounds in the tissues and organs in a freeze-dried whole-body section of small animals such as rats and mice, the sections are pressed against a IP for exposure and the IP is scanned by Bio-Imaging Analyzer (Fuji Photo Film Co., Ltd) and a digital autoradiographic image is given. Quantitative data concerning the activity in different tissues can be obtained using an isotope scale as a reference source. Fading effect, application of IP system for distribution of receptor binding ARG, analysis of radio-spots on TLC and radioactive concentration in liquid such as blood are also discussed. (author)

  15. Potential Application of Quantitative Prostate-specific Antigen Analysis in Forensic Examination of Seminal Stains

    Directory of Open Access Journals (Sweden)

    Zhenping Liu

    2015-01-01

    Full Text Available The aims of this study are to use quantitative analysis of the prostate-specific antigen (PSA in the seminal stain examination and to explore the practical value of this analysis in forensic science. For a comprehensive analysis, vaginal swabs from 48 rape cases were tested both by a PSA fluorescence analyzer (i-CHROMA Reader and by a conventional PSA strip test. To confirm the results of these PSA tests, seminal DNA was tested following differential extraction. Compared to the PSA strip test, the PSA rapid quantitative fluorescence analyzer provided the more accurate and sensitive results. More importantly, individualized schemes based on quantitative PSA results of samples can be developed to improve the quality and procedural efficiency in the forensic seminal inspection of samples prior to DNA analysis.

  16. Practice Facilitators' and Leaders' Perspectives on a Facilitated Quality Improvement Program.

    Science.gov (United States)

    McHugh, Megan; Brown, Tiffany; Liss, David T; Walunas, Theresa L; Persell, Stephen D

    2018-04-01

    Practice facilitation is a promising approach to helping practices implement quality improvements. Our purpose was to describe practice facilitators' and practice leaders' perspectives on implementation of a practice facilitator-supported quality improvement program and describe where their perspectives aligned and diverged. We conducted interviews with practice leaders and practice facilitators who participated in a program that included 35 improvement strategies aimed at the ABCS of heart health (aspirin use in high-risk individuals, blood pressure control, cholesterol management, and smoking cessation). Rapid qualitative analysis was used to collect, organize, and analyze the data. We interviewed 17 of the 33 eligible practice leaders, and the 10 practice facilitators assigned to those practices. Practice leaders and practice facilitators both reported value in the program's ability to bring needed, high-quality resources to practices. Practice leaders appreciated being able to set the schedule for facilitation and select among the 35 interventions. According to practice facilitators, however, relying on practice leaders to set the pace of the intervention resulted in a lower level of program intensity than intended. Practice leaders preferred targeted assistance, particularly electronic health record documentation guidance and linkages to state smoking cessation programs. Practice facilitators reported that the easiest interventions were those that did not alter care practices. The dual perspectives of practice leaders and practice facilitators provide a more holistic picture of enablers and barriers to program implementation. There may be greater opportunities to assist small practices through simple, targeted practice facilitator-supported efforts rather than larger, comprehensive quality improvement projects. © 2018 Annals of Family Medicine, Inc.

  17. On the Need for Quantitative Bias Analysis in the Peer-Review Process.

    Science.gov (United States)

    Fox, Matthew P; Lash, Timothy L

    2017-05-15

    Peer review is central to the process through which epidemiologists generate evidence to inform public health and medical interventions. Reviewers thereby act as critical gatekeepers to high-quality research. They are asked to carefully consider the validity of the proposed work or research findings by paying careful attention to the methodology and critiquing the importance of the insight gained. However, although many have noted problems with the peer-review system for both manuscripts and grant submissions, few solutions have been proposed to improve the process. Quantitative bias analysis encompasses all methods used to quantify the impact of systematic error on estimates of effect in epidemiologic research. Reviewers who insist that quantitative bias analysis be incorporated into the design, conduct, presentation, and interpretation of epidemiologic research could substantially strengthen the process. In the present commentary, we demonstrate how quantitative bias analysis can be used by investigators and authors, reviewers, funding agencies, and editors. By utilizing quantitative bias analysis in the peer-review process, editors can potentially avoid unnecessary rejections, identify key areas for improvement, and improve discussion sections by shifting from speculation on the impact of sources of error to quantification of the impact those sources of bias may have had. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Quantitative assessment of videolaryngostroboscopic images in patients with glottic pathologies.

    Science.gov (United States)

    Niebudek-Bogusz, Ewa; Kopczynski, Bartosz; Strumillo, Pawel; Morawska, Joanna; Wiktorowicz, Justyna; Sliwinska-Kowalska, Mariola

    2017-07-01

    Digital imaging techniques enable exploration of novel visualization modalities of the vocal folds during phonation and definition of parameters, facilitating more precise diagnosis of voice disorders. Application of computer vision algorithms for analysis of videolaryngostroboscopic (VLS) images aimed at qualitative and quantitative description of phonatory vibrations. VLS examinations were conducted for 45 females, including 15 subjects with vocal nodules, 15 subjects with glottal incompetence, and 15 normophonic females. The recorded VLS images were preprocessed, the glottis area was segmented out, and the glottal cycles were identified. The glottovibrograms were built, and then the glottal area waveforms (GAW) were quantitatively described by computing the following parameters: open quotient (OQ), closing quotient (CQ), speed quotient (SQ), minimal relative glottal area (MRGA), and a new parameter termed closure difference index (CDI). Profiles of the glottal widths assessed along the glottal length differentiated the study groups (P diagnostics. Results of the performed ROC curve analysis suggest that the evaluated parameters can distinguish patients with voice disorders from normophonic subjects.

  19. Quantitative Determination of Aluminum in Deodorant Brands: A Guided Inquiry Learning Experience in Quantitative Analysis Laboratory

    Science.gov (United States)

    Sedwick, Victoria; Leal, Anne; Turner, Dea; Kanu, A. Bakarr

    2018-01-01

    The monitoring of metals in commercial products is essential for protecting public health against the hazards of metal toxicity. This article presents a guided inquiry (GI) experimental lab approach in a quantitative analysis lab class that enabled students' to determine the levels of aluminum in deodorant brands. The utility of a GI experimental…

  20. Quantitative data analysis with SPSS release 8 for Windows a guide for social scientists

    CERN Document Server

    Bryman, Alan

    2002-01-01

    The latest edition of this best-selling introduction to Quantitative Data Analysis through the use of a computer package has been completely updated to accommodate the needs of users of SPSS Release 8 for Windows. Like its predecessor, it provides a non-technical approach to quantitative data analysis and a user-friendly introduction to the widely used SPSS for Windows. It assumes no previous familiarity with either statistics or computing but takes the reader step-by-step through the techniques, reinforced by exercises for further practice. Techniques explained in Quantitative Data Analysis with SPSS Release 8 for Windows include: * correlation * simple and multiple regression * multivariate analysis of variance and covariance * factor analysis The book also covers issues such as sampling, statistical significance, conceptualization and measurement and the selection of appropriate tests. For further information or to download the book's datasets, please visit the webstite: http://www.routledge.com/textbooks/...

  1. Quantitative analysis on electrooculography (EOG) for neurodegenerative disease

    Science.gov (United States)

    Liu, Chang-Chia; Chaovalitwongse, W. Art; Pardalos, Panos M.; Seref, Onur; Xanthopoulos, Petros; Sackellares, J. C.; Skidmore, Frank M.

    2007-11-01

    Many studies have documented abnormal horizontal and vertical eye movements in human neurodegenerative disease as well as during altered states of consciousness (including drowsiness and intoxication) in healthy adults. Eye movement measurement may play an important role measuring the progress of neurodegenerative diseases and state of alertness in healthy individuals. There are several techniques for measuring eye movement, Infrared detection technique (IR). Video-oculography (VOG), Scleral eye coil and EOG. Among those available recording techniques, EOG is a major source for monitoring the abnormal eye movement. In this real-time quantitative analysis study, the methods which can capture the characteristic of the eye movement were proposed to accurately categorize the state of neurodegenerative subjects. The EOG recordings were taken while 5 tested subjects were watching a short (>120 s) animation clip. In response to the animated clip the participants executed a number of eye movements, including vertical smooth pursued (SVP), horizontal smooth pursued (HVP) and random saccades (RS). Detection of abnormalities in ocular movement may improve our diagnosis and understanding a neurodegenerative disease and altered states of consciousness. A standard real-time quantitative analysis will improve detection and provide a better understanding of pathology in these disorders.

  2. Quantitative XPS analysis of high Tc superconductor surfaces

    International Nuclear Information System (INIS)

    Jablonski, A.; Sanada, N.; Suzuki, Y.; Fukuda, Y.; Nagoshi, M.

    1993-01-01

    The procedure of quantitative XPS analysis involving the relative sensitivity factors is most convenient to apply to high T c superconductor surfaces because this procedure does not require standards. However, a considerable limitation of such an approach is its relatively low accuracy. In the present work, a proposition is made to use for this purpose a modification of the relative sensitivity factor approach accounting for the matrix and the instrumental effects. The accuracy of this modification when applied to the binary metal alloys is 2% or better. A quantitative XPS analysis was made for surfaces of the compounds Bi 2 Sr 2 CuO 6 , Bi 2 Sr 2 CaCu 2 O 8 , and YBa 2 Cu 3 O Y . The surface composition determined for the polycrystalline samples corresponds reasonably well to the bulk stoichiometry. Slight deficiency of oxygen was found for the Bi-based compounds. The surface exposed on cleavage of the Bi 2 Sr 2 CaCu 2 O 8 single crystal was found to be enriched with bismuth, which indicates that the cleavage occurs along the BiO planes. This result is in agreement with the STM studies published in the literature

  3. Quantitative Analysis of Complex Tropical Forest Stands: A Review ...

    African Journals Online (AJOL)

    The importance of data analysis in quantitative assessment of natural resources remains significant in the sustainable management of complex tropical forest resources. Analyses of data from complex tropical forest stands have not been easy or clear due to improper data management. It is pivotal to practical researches ...

  4. Quantitative Proteomic Analysis of Mosquito C6/36 Cells Reveals Host Proteins Involved in Zika Virus Infection.

    Science.gov (United States)

    Xin, Qi-Lin; Deng, Cheng-Lin; Chen, Xi; Wang, Jun; Wang, Shao-Bo; Wang, Wei; Deng, Fei; Zhang, Bo; Xiao, Gengfu; Zhang, Lei-Ke

    2017-06-15

    Zika virus (ZIKV) is an emerging arbovirus belonging to the genus Flavivirus of the family Flaviviridae During replication processes, flavivirus manipulates host cell systems to facilitate its replication, while the host cells activate antiviral responses. Identification of host proteins involved in the flavivirus replication process may lead to the discovery of antiviral targets. The mosquitoes Aedes aegypti and Aedes albopictus are epidemiologically important vectors for ZIKV, and effective restrictions of ZIKV replication in mosquitoes will be vital in controlling the spread of virus. In this study, an iTRAQ-based quantitative proteomic analysis of ZIKV-infected Aedes albopictus C6/36 cells was performed to investigate host proteins involved in the ZIKV infection process. A total of 3,544 host proteins were quantified, with 200 being differentially regulated, among which CHCHD2 can be upregulated by ZIKV infection in both mosquito C6/36 and human HeLa cells. Our further study indicated that CHCHD2 can promote ZIKV replication and inhibit beta interferon (IFN-β) production in HeLa cells, suggesting that ZIKV infection may upregulate CHCHD2 to inhibit IFN-I production and thus promote virus replication. Bioinformatics analysis of regulated host proteins highlighted several ZIKV infection-regulated biological processes. Further study indicated that the ubiquitin proteasome system (UPS) plays roles in the ZIKV entry process and that an FDA-approved inhibitor of the 20S proteasome, bortezomib, can inhibit ZIKV infection in vivo Our study illustrated how host cells respond to ZIKV infection and also provided a candidate drug for the control of ZIKV infection in mosquitoes and treatment of ZIKV infection in patients. IMPORTANCE ZIKV infection poses great threats to human health, and there is no FDA-approved drug available for the treatment of ZIKV infection. During replication, ZIKV manipulates host cell systems to facilitate its replication, while host cells activate

  5. Database for Simulation of Electron Spectra for Surface Analysis (SESSA)Database for Simulation of Electron Spectra for Surface Analysis (SESSA)

    Science.gov (United States)

    SRD 100 Database for Simulation of Electron Spectra for Surface Analysis (SESSA)Database for Simulation of Electron Spectra for Surface Analysis (SESSA) (PC database for purchase)   This database has been designed to facilitate quantitative interpretation of Auger-electron and X-ray photoelectron spectra and to improve the accuracy of quantitation in routine analysis. The database contains all physical data needed to perform quantitative interpretation of an electron spectrum for a thin-film specimen of given composition. A simulation module provides an estimate of peak intensities as well as the energy and angular distributions of the emitted electron flux.

  6. Stable isotope labeling – Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids

    International Nuclear Information System (INIS)

    Guo, Ning; Liu, Ping; Ding, Jun; Zheng, Shu-Jian; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-01-01

    Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d_5-Girard reagent P (d_5-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4–504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones related

  7. Stable isotope labeling – Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ning; Liu, Ping; Ding, Jun; Zheng, Shu-Jian; Yuan, Bi-Feng; Feng, Yu-Qi, E-mail: yqfeng@whu.edu.cn

    2016-01-28

    Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d{sub 5}-Girard reagent P (d{sub 5}-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4–504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones

  8. A three-component system incorporating Ppd-D1, copy number variation at Ppd-B1, and numerous small-effect quantitative trait loci facilitates adaptation of heading time in winter wheat cultivars of worldwide origin.

    Science.gov (United States)

    Würschum, Tobias; Langer, Simon M; Longin, C Friedrich H; Tucker, Matthew R; Leiser, Willmar L

    2018-06-01

    The broad adaptability of heading time has contributed to the global success of wheat in a diverse array of climatic conditions. Here, we investigated the genetic architecture underlying heading time in a large panel of 1,110 winter wheat cultivars of worldwide origin. Genome-wide association mapping, in combination with the analysis of major phenology loci, revealed a three-component system that facilitates the adaptation of heading time in winter wheat. The photoperiod sensitivity locus Ppd-D1 was found to account for almost half of the genotypic variance in this panel and can advance or delay heading by many days. In addition, copy number variation at Ppd-B1 was the second most important source of variation in heading, explaining 8.3% of the genotypic variance. Results from association mapping and genomic prediction indicated that the remaining variation is attributed to numerous small-effect quantitative trait loci that facilitate fine-tuning of heading to the local climatic conditions. Collectively, our results underpin the importance of the two Ppd-1 loci for the adaptation of heading time in winter wheat and illustrate how the three components have been exploited for wheat breeding globally. © 2018 John Wiley & Sons Ltd.

  9. Quantitative analysis of eyes and other optical systems in linear optics.

    Science.gov (United States)

    Harris, William F; Evans, Tanya; van Gool, Radboud D

    2017-05-01

    To show that 14-dimensional spaces of augmented point P and angle Q characteristics, matrices obtained from the ray transference, are suitable for quantitative analysis although only the latter define an inner-product space and only on it can one define distances and angles. The paper examines the nature of the spaces and their relationships to other spaces including symmetric dioptric power space. The paper makes use of linear optics, a three-dimensional generalization of Gaussian optics. Symmetric 2 × 2 dioptric power matrices F define a three-dimensional inner-product space which provides a sound basis for quantitative analysis (calculation of changes, arithmetic means, etc.) of refractive errors and thin systems. For general systems the optical character is defined by the dimensionally-heterogeneous 4 × 4 symplectic matrix S, the transference, or if explicit allowance is made for heterocentricity, the 5 × 5 augmented symplectic matrix T. Ordinary quantitative analysis cannot be performed on them because matrices of neither of these types constitute vector spaces. Suitable transformations have been proposed but because the transforms are dimensionally heterogeneous the spaces are not naturally inner-product spaces. The paper obtains 14-dimensional spaces of augmented point P and angle Q characteristics. The 14-dimensional space defined by the augmented angle characteristics Q is dimensionally homogenous and an inner-product space. A 10-dimensional subspace of the space of augmented point characteristics P is also an inner-product space. The spaces are suitable for quantitative analysis of the optical character of eyes and many other systems. Distances and angles can be defined in the inner-product spaces. The optical systems may have multiple separated astigmatic and decentred refracting elements. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  10. Biotin Switch Assays for Quantitation of Reversible Cysteine Oxidation.

    Science.gov (United States)

    Li, R; Kast, J

    2017-01-01

    Thiol groups in protein cysteine residues can be subjected to different oxidative modifications by reactive oxygen/nitrogen species. Reversible cysteine oxidation, including S-nitrosylation, S-sulfenylation, S-glutathionylation, and disulfide formation, modulate multiple biological functions, such as enzyme catalysis, antioxidant, and other signaling pathways. However, the biological relevance of reversible cysteine oxidation is typically underestimated, in part due to the low abundance and high reactivity of some of these modifications, and the lack of methods to enrich and quantify them. To facilitate future research efforts, this chapter describes detailed procedures to target the different modifications using mass spectrometry-based biotin switch assays. By switching the modification of interest to a biotin moiety, these assays leverage the high affinity between biotin and avidin to enrich the modification. The use of stable isotope labeling and a range of selective reducing agents facilitate the quantitation of individual as well as total reversible cysteine oxidation. The biotin switch assay has been widely applied to the quantitative analysis of S-nitrosylation in different disease models and is now also emerging as a valuable research tool for other oxidative cysteine modifications, highlighting its relevance as a versatile, robust strategy for carrying out in-depth studies in redox proteomics. © 2017 Elsevier Inc. All rights reserved.

  11. Quantitative X ray analysis system. User's manual and guide to X ray fluorescence technique

    International Nuclear Information System (INIS)

    2009-01-01

    This guide covers trimmed and re-arranged version 3.6 of the Quantitative X ray Analysis System (QXAS) software package that includes the most frequently used methods of quantitative analysis. QXAS is a comprehensive quantitative analysis package that has been developed by the IAEA through research and technical contracts. Additional development has also been carried out in the IAEA Laboratories in Seibersdorf where QXAS was extensively tested. New in this version of the manual are the descriptions of the Voigt-profile peak fitting, the backscatter fundamental parameters' and emission-transmission methods of chemical composition analysis, an expanded chapter on the X ray fluorescence physics, and completely revised and increased number of practical examples of utilization of the QXAS software package. The analytical data accompanying this manual were collected in the IAEA Seibersdorf Laboratories in the years 2006/2007

  12. Quantitative proteomic analysis of intact plastids.

    Science.gov (United States)

    Shiraya, Takeshi; Kaneko, Kentaro; Mitsui, Toshiaki

    2014-01-01

    Plastids are specialized cell organelles in plant cells that are differentiated into various forms including chloroplasts, chromoplasts, and amyloplasts, and fulfill important functions in maintaining the overall cell metabolism and sensing environmental factors such as sunlight. It is therefore important to grasp the mechanisms of differentiation and functional changes of plastids in order to enhance the understanding of vegetality. In this chapter, details of a method for the extraction of intact plastids that makes analysis possible while maintaining the plastid functions are provided; in addition, a quantitative shotgun method for analyzing the composition and changes in the content of proteins in plastids as a result of environmental impacts is described.

  13. Quantitative analysis of elastography images in the detection of breast cancer

    International Nuclear Information System (INIS)

    Landoni, V.; Francione, V.; Marzi, S.; Pasciuti, K.; Ferrante, F.; Saracca, E.; Pedrini, M.; Strigari, L.; Crecco, M.; Di Nallo, A.

    2012-01-01

    Purpose: The aim of this study was to develop a quantitative method for breast cancer diagnosis based on elastosonography images in order to reduce whenever possible unnecessary biopsies. The proposed method was validated by correlating the results of quantitative analysis with the diagnosis assessed by histopathologic exam. Material and methods: 109 images of breast lesions (50 benign and 59 malignant) were acquired with the traditional B-mode technique and with elastographic modality. Images in Digital Imaging and COmmunications in Medicine format (DICOM) were exported into a software, written in Visual Basic, especially developed to perform this study. The lesion was contoured and the mean grey value and softness inside the region of interest (ROI) were calculated. The correlations between variables were investigated and receiver operating characteristic (ROC) curve analysis was performed to assess the diagnostic accuracy of the proposed method. Pathologic results were used as standard reference. Results: Both the mean grey value and the softness inside the ROI resulted statistically different at the t test for the two populations of lesions (i.e., benign versus malignant): p < 0.0001. The area under the curve (AUC) was 0.924 (0.834–0.973) and 0.917 (0.826–0.970) for the mean grey value and for the softness respectively. Conclusions: Quantitative elastosonography is a promising ultrasound technique in the detection of breast cancer but large prospective trials are necessary to determine whether quantitative analysis of images can help to overcome some pitfalls of the methodic.

  14. Renal geology (quantitative renal stone analysis) by 'Fourier transform infrared spectroscopy'.

    Science.gov (United States)

    Singh, Iqbal

    2008-01-01

    To prospectively determine the precise stone composition (quantitative analysis) by using infrared spectroscopy in patients with urinary stone disease presenting to our clinic. To determine an ideal method for stone analysis suitable for use in a clinical setting. After routine and a detailed metabolic workup of all patients of urolithiasis, stone samples of 50 patients of urolithiasis satisfying the entry criteria were subjected to the Fourier transform infrared spectroscopic analysis after adequate sample homogenization at a single testing center. Calcium oxalate monohydrate and dihydrate stone mixture was most commonly encountered in 35 (71%) followed by calcium phosphate, carbonate apatite, magnesium ammonium hexahydrate and xanthine stones. Fourier transform infrared spectroscopy allows an accurate, reliable quantitative method of stone analysis. It also helps in maintaining a computerized large reference library. Knowledge of precise stone composition may allow the institution of appropriate prophylactic therapy despite the absence of any detectable metabolic abnormalities. This may prevent and or delay stone recurrence.

  15. Quantitative proteomic analysis of ibuprofen-degrading Patulibacter sp. strain I11

    DEFF Research Database (Denmark)

    Almeida, Barbara; Kjeldal, Henrik; Lolas, Ihab Bishara Yousef

    2013-01-01

    was identified and quantified by gel based shotgun-proteomics. In total 251 unique proteins were quantitated using this approach. Biological process and pathway analysis indicated a number of proteins that were up-regulated in response to active degradation of ibuprofen, some of them are known to be involved...... in the degradation of aromatic compounds. Data analysis revealed that several of these proteins are likely involved in ibuprofen degradation by Patulibacter sp. strain I11.......Ibuprofen is the third most consumed pharmaceutical drug in the world. Several isolates have been shown to degrade ibuprofen, but very little is known about the biochemistry of this process. This study investigates the degradation of ibuprofen by Patulibacter sp. strain I11 by quantitative...

  16. Analysis association of milk fat and protein percent in quantitative ...

    African Journals Online (AJOL)

    Analysis association of milk fat and protein percent in quantitative trait locus ... African Journal of Biotechnology ... Protein and fat percent as content of milk are high-priority criteria for financial aims and selection of programs in dairy cattle.

  17. Contribution of the surface contamination of uranium-materials on the quantitative analysis results by electron probe microbeam analysis

    International Nuclear Information System (INIS)

    Bonino, O.; Fournier, C.; Fucili, C.; Dugne, O.; Merlet, C.

    2000-01-01

    The analytical testing of uranium materials is necessary for quality research and development in nuclear industry applications (enrichment, safety studies, fuel, etc). Electron Probe Microbeam Analysis Wavelength Dispersive Spectrometry (EPMA-WDS) is a dependable non-destructive analytical technology. The characteristic X-ray signal is measured to identify and quantify the sample components, and the analyzed volume is about one micron cube. The surface contamination of uranium materials modifies and contributes to the quantitative analysis results of EPMA-WDS. This contribution is not representative of the bulk. A thin oxidized layer appears in the first instants after preparation (burnishing, cleaning) as well as a carbon contamination layer, due to metallographic preparation and carbon cracking under the impact of the electron probe. Several analytical difficulties subsequently arise, including an overlapping line between the carbon Ka ray and the Uranium U NIVOVI ray. Sensitivity and accuracy of the quantification of light elements like carbon and oxygen are also reduced by the presence of uranium. The aim of this study was to improve the accuracy of quantitative analysis on uranium materials by EPMA-WDS by taking account of the contribution of surface contamination. The first part of this paper is devoted to the study of the contaminated surface of the uranium materials U, UFe 2 and U 6 Fe a few hours after preparation. These oxidation conditions are selected so as to reproduce the same contamination surfaces occurring in microprobe analytical conditions. Surface characterization techniques were SIMS and Auger spectroscopy. The contaminated surfaces are shown. They consist of successive layers: a carbon layer, an oxidized iron layer, followed by an iron depletion layer (only in UFe 2 and U 6 Fe), and a ternary oxide layer (U-Fe-O for UFe 2 et U 6 Fe and UO 2+x for uranium). The second part of the paper addresses the estimation of the errors in quantitative

  18. A new quantitative analysis on nitriding kinetics in the oxidized Zry-4 at 900-1200 .deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sanggi [ACT Co. Ltd., Daejeon (Korea, Republic of)

    2016-10-15

    Two major roles of nitrogen on the zirconium based cladding degradation were identified: mechanical degradation of the cladding, and the additional chemical heat release. It has long been known that accelerated oxidation can occur in air due to the nitrogen. In addition, significant uptake of nitrogen can also occur. The nitriding of pre-oxidized zirconium based alloys leads to micro porous and less coherent oxide scales. This paper aims to quantitatively investigate the nitriding mechanism and kinetics by proposing a new methodology that is coupled with the mass balance analysis and the optical microscope image processing analysis. A new quantitative analysis methodology is described in chapter 2 and the investigation of the nitriding kinetics is performed in chapter 3. The experimental details are previously reported in. Previously only qualitative analysis was performed in, and hence the quantitative analysis will be performed in this paper. In this paper, the nitriding kinetics and mechanism were quantitatively analyzed by the new proposed analysis methods: the mass balance analysis and the optical microscope image processing analysis. Using these combined methods, the mass gain curves and the optical microscopes are analyzed in very detail, and the mechanisms of nitriding accelerated, stabilized and saturated behaviors were well understood. This paper has two very distinctive achievements as follows: 1) Development of very effective quantitative analysis methods only using two main results of oxidation tests: No detailed analytical sample measurements (e.g. TEM, EPMA and so on.) were required. These methods can effectively reduce the cost and effort of the post-test investigation. 2) The first identification of the nitriding behaviors and its very accurate analysis in a quantitative way. Based on this quantitative analysis results on the nitriding kinetics, these new findings will contribute significantly the understanding the air oxidation behaviors and model

  19. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    Science.gov (United States)

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  20. Quantitative analysis of γ–oryzanol content in cold pressed rice bran oil by TLC–image analysis method

    Directory of Open Access Journals (Sweden)

    Apirak Sakunpak

    2014-02-01

    Conclusions: The TLC-densitometric and TLC-image analysis methods provided a similar reproducibility, accuracy and selectivity for the quantitative determination of γ-oryzanol in cold pressed rice bran oil. A statistical comparison of the quantitative determinations of γ-oryzanol in samples did not show any statistically significant difference between TLC-densitometric and TLC-image analysis methods. As both methods were found to be equal, they therefore can be used for the determination of γ-oryzanol in cold pressed rice bran oil.

  1. Optimal climate policy is a utopia. From quantitative to qualitative cost-benefit analysis

    International Nuclear Information System (INIS)

    Van den Bergh, Jeroen C.J.M.

    2004-01-01

    The dominance of quantitative cost-benefit analysis (CBA) and optimality concepts in the economic analysis of climate policy is criticised. Among others, it is argued to be based in a misplaced interpretation of policy for a complex climate-economy system as being analogous to individual inter-temporal welfare optimisation. The transfer of quantitative CBA and optimality concepts reflects an overly ambitious approach that does more harm than good. An alternative approach is to focus the attention on extreme events, structural change and complexity. It is argued that a qualitative rather than a quantitative CBA that takes account of these aspects can support the adoption of a minimax regret approach or precautionary principle in climate policy. This means: implement stringent GHG reduction policies as soon as possible

  2. Method of quantitative analysis of superconducting metal-conducting composite materials

    International Nuclear Information System (INIS)

    Bogomolov, V.N.; Zhuravlev, V.V.; Petranovskij, V.P.; Pimenov, V.A.

    1990-01-01

    Technique for quantitative analysis of superconducting metal-containing composite materials, SnO 2 -InSn, WO 3 -InW, Zn)-InZn in particular, has been developed. The method of determining metal content in a composite is based on the dependence of superconducting transition temperature on alloy composition. Sensitivity of temperature determination - 0.02K, error of analysis for InSn system - 0.5%

  3. Meta-analysis for quantitative microbiological risk assessments and benchmarking data

    NARCIS (Netherlands)

    Besten, den H.M.W.; Zwietering, M.H.

    2012-01-01

    Meta-analysis studies are increasingly being conducted in the food microbiology area to quantitatively integrate the findings of many individual studies on specific questions or kinetic parameters of interest. Meta-analyses provide global estimates of parameters and quantify their variabilities, and

  4. Visual and Quantitative Analysis Methods of Respiratory Patterns for Respiratory Gated PET/CT.

    Science.gov (United States)

    Son, Hye Joo; Jeong, Young Jin; Yoon, Hyun Jin; Park, Jong-Hwan; Kang, Do-Young

    2016-01-01

    We integrated visual and quantitative methods for analyzing the stability of respiration using four methods: phase space diagrams, Fourier spectra, Poincaré maps, and Lyapunov exponents. Respiratory patterns of 139 patients were grouped based on the combination of the regularity of amplitude, period, and baseline positions. Visual grading was done by inspecting the shape of diagram and classified into two states: regular and irregular. Quantitation was done by measuring standard deviation of x and v coordinates of Poincaré map (SD x , SD v ) or the height of the fundamental peak ( A 1 ) in Fourier spectrum or calculating the difference between maximal upward and downward drift. Each group showed characteristic pattern on visual analysis. There was difference of quantitative parameters (SD x , SD v , A 1 , and MUD-MDD) among four groups (one way ANOVA, p = 0.0001 for MUD-MDD, SD x , and SD v , p = 0.0002 for A 1 ). In ROC analysis, the cutoff values were 0.11 for SD x (AUC: 0.982, p quantitative indices of respiratory stability and determining quantitative cutoff value for differentiating regular and irregular respiration.

  5. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    International Nuclear Information System (INIS)

    Fernandez-Ruiz, R.; Garcia-Heras, M.

    2008-01-01

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies

  6. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Grupo de Arqueometria de Vidrios y Materiales Ceramicos, Instituto de Historia, Centro de Ciencias Humanas y Sociales, CSIC, C/ Albasanz, 26-28, 28037 Madrid (Spain)

    2008-09-15

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies.

  7. Study on methods of quantitative analysis of the biological thin samples in EM X-ray microanalysis

    International Nuclear Information System (INIS)

    Zhang Detian; Zhang Xuemin; He Kun; Yang Yi; Zhang Sa; Wang Baozhen

    2000-01-01

    Objective: To study the methods of quantitative analysis of the biological thin samples. Methods: Hall theory was used to study the qualitative analysis, background subtraction, peel off overlap peaks; external radiation and aberrance of spectra. Results: The results of reliable qualitative analysis and precise quantitative analysis were achieved. Conclusion: The methods for analysis of the biological thin samples in EM X-ray microanalysis can be used in biomedical research

  8. Quantitative x-ray fractographic analysis of fatigue fractures

    International Nuclear Information System (INIS)

    Saprykin, Yu.V.

    1983-01-01

    The study deals with quantitative X-ray fractographic investigation of fatigue fractures of samples with sharp notches tested at various stresses and temperatures with the purpose of establishing a connection between material crack resistance parameters and local plastic instability zones restraining and controlling the crack growth. At fatigue fractures of notched Kh18N9T steel samples tested at +20 and -196 deg C a zone of sharp ring notch effect being analogous to the zone in which crack growth rate is controlled by the microshifting mechanisms is singled out. The size of the notched effect zone in the investigate steel is unambiguosly bound to to the stress amplitude. This provides the possibility to determine the stress value by the results of quantitative fractographic analysis of notched sample fractures. A possibility of determining one of the threshold values of cyclic material fracture toughness by the results of fatigue testing and fractography of notched sample fractures is shown. Correlation between the size of the hsub(s) crack effect zone in the notched sample, delta material yield limit and characteristic of cyclic Ksub(s) fracture toughness has been found. Such correlation widens the possibilities of quantitative diagnostics of fractures by the methods of X-ray fractography

  9. Wavelength Selection Method Based on Differential Evolution for Precise Quantitative Analysis Using Terahertz Time-Domain Spectroscopy.

    Science.gov (United States)

    Li, Zhi; Chen, Weidong; Lian, Feiyu; Ge, Hongyi; Guan, Aihong

    2017-12-01

    Quantitative analysis of component mixtures is an important application of terahertz time-domain spectroscopy (THz-TDS) and has attracted broad interest in recent research. Although the accuracy of quantitative analysis using THz-TDS is affected by a host of factors, wavelength selection from the sample's THz absorption spectrum is the most crucial component. The raw spectrum consists of signals from the sample and scattering and other random disturbances that can critically influence the quantitative accuracy. For precise quantitative analysis using THz-TDS, the signal from the sample needs to be retained while the scattering and other noise sources are eliminated. In this paper, a novel wavelength selection method based on differential evolution (DE) is investigated. By performing quantitative experiments on a series of binary amino acid mixtures using THz-TDS, we demonstrate the efficacy of the DE-based wavelength selection method, which yields an error rate below 5%.

  10. Quantitative texture analysis of electrodeposited line patterns

    DEFF Research Database (Denmark)

    Pantleon, Karen; Somers, Marcel A.J.

    2005-01-01

    Free-standing line patterns of Cu and Ni were manufactured by electrochemical deposition into lithographically prepared patterns. Electrodeposition was carried out on top of a highly oriented Au-layer physically vapor deposited on glass. Quantitative texture analysis carried out by means of x......-ray diffraction for both the substrate layer and the electrodeposits yielded experimental evidence for epitaxy between Cu and Au. An orientation relation between film and substrate was discussed with respect to various concepts of epitaxy. While the conventional mode of epitaxy fails for the Cu...

  11. Quantitative and Qualitative Evaluations of the Enhanced Logo-autobiography Program for Korean-American Women.

    Science.gov (United States)

    Sung, Kyung Mi; Bernstein, Kunsook

    2017-12-01

    This study extends Bernstein et al.'s (2016) investigation of the effects of the Enhanced Logo-autobiography Program on Korean-American women's depressive symptoms, coping strategies, purpose in life, and posttraumatic growth by analyzing quantitative and qualitative data. This study's participants significantly improved on quantitative measures of depression, coping strategies, purpose in life, and post-traumatic growth at eight weeks post-intervention and follow-up. The qualitative content analysis revealed 17 themes with five essential themes. The program's activity to promote purpose in life through posttraumatic growth facilitated participants' recovery from traumatic experiences. Standardized guidelines are needed to conduct this program in Korean community centers.

  12. Calibration-free quantitative analysis of elemental ratios in intermetallic nanoalloys and nanocomposites using Laser Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Davari, Seyyed Ali; Hu, Sheng; Mukherjee, Dibyendu

    2017-03-01

    Intermetallic nanoalloys (NAs) and nanocomposites (NCs) have increasingly gained prominence as efficient catalytic materials in electrochemical energy conversion and storage systems. But their morphology and chemical compositions play critical role in tuning their catalytic activities, and precious metal contents. While advanced microscopy techniques facilitate morphological characterizations, traditional chemical characterizations are either qualitative or extremely involved. In this study, we apply Laser Induced Breakdown Spectroscopy (LIBS) for quantitative compositional analysis of NAs and NCs synthesized with varied elemental ratios by our in-house built pulsed laser ablation technique. Specifically, elemental ratios of binary PtNi, PdCo (NAs) and PtCo (NCs) of different compositions are determined from LIBS measurements employing an internal calibration scheme using the bulk matrix species as internal standards. Morphology and qualitative elemental compositions of the aforesaid NAs and NCs are confirmed from Transmission Electron Microscopy (TEM) images and Energy Dispersive X-ray Spectroscopy (EDX) measurements. LIBS experiments are carried out in ambient conditions with the NA and NC samples drop cast on silicon wafers after centrifugation to increase their concentrations. The technique does not call for cumbersome sample preparations including acid digestions and external calibration standards commonly required in Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) techniques. Yet the quantitative LIBS results are in good agreement with the results from ICP-OES measurements. Our results indicate the feasibility of using LIBS in future for rapid and in-situ quantitative chemical characterizations of wide classes of synthesized NAs and NCs. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Joint analysis of binary and quantitative traits with data sharing and outcome-dependent sampling.

    Science.gov (United States)

    Zheng, Gang; Wu, Colin O; Kwak, Minjung; Jiang, Wenhua; Joo, Jungnam; Lima, Joao A C

    2012-04-01

    We study the analysis of a joint association between a genetic marker with both binary (case-control) and quantitative (continuous) traits, where the quantitative trait values are only available for the cases due to data sharing and outcome-dependent sampling. Data sharing becomes common in genetic association studies, and the outcome-dependent sampling is the consequence of data sharing, under which a phenotype of interest is not measured for some subgroup. The trend test (or Pearson's test) and F-test are often, respectively, used to analyze the binary and quantitative traits. Because of the outcome-dependent sampling, the usual F-test can be applied using the subgroup with the observed quantitative traits. We propose a modified F-test by also incorporating the genotype frequencies of the subgroup whose traits are not observed. Further, a combination of this modified F-test and Pearson's test is proposed by Fisher's combination of their P-values as a joint analysis. Because of the correlation of the two analyses, we propose to use a Gamma (scaled chi-squared) distribution to fit the asymptotic null distribution for the joint analysis. The proposed modified F-test and the joint analysis can also be applied to test single trait association (either binary or quantitative trait). Through simulations, we identify the situations under which the proposed tests are more powerful than the existing ones. Application to a real dataset of rheumatoid arthritis is presented. © 2012 Wiley Periodicals, Inc.

  14. Investment appraisal using quantitative risk analysis.

    Science.gov (United States)

    Johansson, Henrik

    2002-07-01

    Investment appraisal concerned with investments in fire safety systems is discussed. Particular attention is directed at evaluating, in terms of the Bayesian decision theory, the risk reduction that investment in a fire safety system involves. It is shown how the monetary value of the change from a building design without any specific fire protection system to one including such a system can be estimated by use of quantitative risk analysis, the results of which are expressed in terms of a Risk-adjusted net present value. This represents the intrinsic monetary value of investing in the fire safety system. The method suggested is exemplified by a case study performed in an Avesta Sheffield factory.

  15. GProX, a User-Friendly Platform for Bioinformatics Analysis and Visualization of Quantitative Proteomics Data

    DEFF Research Database (Denmark)

    Rigbolt, Kristoffer T G; Vanselow, Jens T; Blagoev, Blagoy

    2011-01-01

    -friendly platform for comprehensive analysis, inspection and visualization of quantitative proteomics data we developed the Graphical Proteomics Data Explorer (GProX)(1). The program requires no special bioinformatics training, as all functions of GProX are accessible within its graphical user-friendly interface...... such as database querying, clustering based on abundance ratios, feature enrichment tests for e.g. GO terms and pathway analysis tools. A number of plotting options for visualization of quantitative proteomics data is available and most analysis functions in GProX create customizable high quality graphical...... displays in both vector and bitmap formats. The generic import requirements allow data originating from essentially all mass spectrometry platforms, quantitation strategies and software to be analyzed in the program. GProX represents a powerful approach to proteomics data analysis providing proteomics...

  16. Novice facilitators and the use of scripts for managing facilitated modelling workshops

    DEFF Research Database (Denmark)

    Tavella, Elena; Papadopoulos, Thanos

    2015-01-01

    There is limited research on the use of scripts by novice facilitators (novices) in Facilitated Modelling (FM) workshops. To address this gap, this paper illustrates how novices—supported by scripts—switch between and combine facilitation skills and competencies to successfully manage FM workshops...... and achieve outcomes. This illustration is based on a micro-level analysis of a transcript from a Viable System Model workshop held in a food cooperative in Copenhagen, Denmark. Through our findings we identify two distinct script-supported FM behaviours and related script-supported facilitation practices...... that enable novices to (a) acquire skills and competencies; and (b) switch between and combine skills and competencies to successfully manage workshops and achieve outcomes. Our study links micro-level considerations to a meta-level framework that relates the script-supported FM behaviours and practices...

  17. Survival Prediction in Pancreatic Ductal Adenocarcinoma by Quantitative Computed Tomography Image Analysis.

    Science.gov (United States)

    Attiyeh, Marc A; Chakraborty, Jayasree; Doussot, Alexandre; Langdon-Embry, Liana; Mainarich, Shiana; Gönen, Mithat; Balachandran, Vinod P; D'Angelica, Michael I; DeMatteo, Ronald P; Jarnagin, William R; Kingham, T Peter; Allen, Peter J; Simpson, Amber L; Do, Richard K

    2018-04-01

    Pancreatic cancer is a highly lethal cancer with no established a priori markers of survival. Existing nomograms rely mainly on post-resection data and are of limited utility in directing surgical management. This study investigated the use of quantitative computed tomography (CT) features to preoperatively assess survival for pancreatic ductal adenocarcinoma (PDAC) patients. A prospectively maintained database identified consecutive chemotherapy-naive patients with CT angiography and resected PDAC between 2009 and 2012. Variation in CT enhancement patterns was extracted from the tumor region using texture analysis, a quantitative image analysis tool previously described in the literature. Two continuous survival models were constructed, with 70% of the data (training set) using Cox regression, first based only on preoperative serum cancer antigen (CA) 19-9 levels and image features (model A), and then on CA19-9, image features, and the Brennan score (composite pathology score; model B). The remaining 30% of the data (test set) were reserved for independent validation. A total of 161 patients were included in the analysis. Training and test sets contained 113 and 48 patients, respectively. Quantitative image features combined with CA19-9 achieved a c-index of 0.69 [integrated Brier score (IBS) 0.224] on the test data, while combining CA19-9, imaging, and the Brennan score achieved a c-index of 0.74 (IBS 0.200) on the test data. We present two continuous survival prediction models for resected PDAC patients. Quantitative analysis of CT texture features is associated with overall survival. Further work includes applying the model to an external dataset to increase the sample size for training and to determine its applicability.

  18. Limitations for qualitative and quantitative neutron activation analysis using reactor neutrons

    International Nuclear Information System (INIS)

    El-Abbady, W.H.; El-Tanahy, Z.H.; El-Hagg, A.A.; Hassan, A.M.

    1999-01-01

    In this work, the most important limitations for qualitative and quantitative analysis using reactor neutrons for activation are reviewed. Each limitation is discussed using different examples of activated samples. Photopeak estimation, nuclear reactions interference and neutron flux measurements are taken into consideration. Solutions for high accuracy evaluation in neutron activation analysis applications are given. (author)

  19. Program for the quantitative and qualitative analysis of

    International Nuclear Information System (INIS)

    Tepelea, V.; Purice, E.; Dan, R.; Calcev, G.; Domnisan, M.; Galis, V.; Teodosiu, G.; Debert, C.; Mocanu, N.; Nastase, M.

    1985-01-01

    A computer code for processing of data from neutron activation analysis is described. The code is capable of qualitative and quantitative analysis of regular spectra from neutron irradiated samples, measured by a Ge(li) detector. Multichannel analysers with 1024 channels, such as TN 1705 or a Romanian made MCA 79, and an ITC interface can be used. The code is implemented on FELIX M118 and FELIX M216 microcomputers. Spectrum processing is performed off line, after storing the data on a floppy disk. The background is assumed to be a polynomial of first, second or third degree. Qualitative analysis is performed by recursive least square, Gaussian curve fitting. The elements are identified using a polynomial relation between energy and channel, obtained by calibration with a standard sample

  20. Facilitation of self-transcendence in a breast cancer support group.

    Science.gov (United States)

    Coward, D D

    1998-01-01

    To examine the feasibility and patterns of effectiveness of a breast cancer support group intervention specifically designed to facilitate self-transcendence views and perspectives that would enhance emotional and physical well-being. Pre-experimental design pilot intervention study with a quantitative approach to data analysis. Survivor-established breast cancer resource center in Austin, TX. Women with recently diagnosed breast cancer (N = 16) participating in 90-minute support group sessions that met weekly for eight weeks. Theory-driven support group intervention facilitated by an oncology clinical nurse specialist, a psychotherapist, and a breast cancer survivor. Activities planned for individual sessions were based on self-transcendence theory, cancer support group literature, and the facilitators' extensive previous support group experience. Self-transcendence, emotional well-being, physical well-being. Good networking, coordination, and follow-up were essential for participant recruitment and retention throughout the intervention period. Although specific theory-driven activities were planned for group sessions, facilitators maintained flexibility in meeting immediate concerns of the participants. Relationships among participants' scores on study variables indicated an association between self-transcendence and emotional well-being. Scores on self-transcendence and well-being variables at the end of the intervention increased from baseline, but only functional performance status, mood state, and satisfaction with life reached statistical significance. The pilot study was invaluable in providing direction for the conduct of future experimental studies. Provides preliminary support for the use of theory-driven activities for promotion of self-transcendence views and behaviors within a cancer support group setting.

  1. Dynamic and gated PET. Quantitative imaging of the heart revisited

    International Nuclear Information System (INIS)

    Nekolla, S.G.

    2005-01-01

    This short overview focuses on the basic implementation as well as applications of cardiac PET studies acquired in dynamic and ECG triggered modes. Both acquisition modes are well suited for quantitative analysis and the advantages of such an approach are discussed. An outlook on the measurement of respiratory triggered studies and the new challenges this data presents is provided. In the context of modern PET/CT tomographs with the combination of high sensitivity and morphologic resolution, the promise of list mode acquisition is investigated. The before mentioned acquisition modes are ideal candidates for this technology the utility of which in a clinical setting is briefly discussed. The retrospective generation of dynamic and gated image data (and any combinations) is greatly facilitated with this approach. Finally, a novel presentation mode for the wealth of quantitative information generated by these systems is presented. (orig.)

  2. Quantitative method of X-ray diffraction phase analysis of building materials

    International Nuclear Information System (INIS)

    Czuba, J.; Dziedzic, A.

    1978-01-01

    Quantitative method of X-ray diffraction phase analysis of building materials, with use of internal standard, has been presented. The errors committed by determining the content of particular phases have been also given. (author)

  3. Semantic Coherence Facilitates Distributional Learning.

    Science.gov (United States)

    Ouyang, Long; Boroditsky, Lera; Frank, Michael C

    2017-04-01

    Computational models have shown that purely statistical knowledge about words' linguistic contexts is sufficient to learn many properties of words, including syntactic and semantic category. For example, models can infer that "postman" and "mailman" are semantically similar because they have quantitatively similar patterns of association with other words (e.g., they both tend to occur with words like "deliver," "truck," "package"). In contrast to these computational results, artificial language learning experiments suggest that distributional statistics alone do not facilitate learning of linguistic categories. However, experiments in this paradigm expose participants to entirely novel words, whereas real language learners encounter input that contains some known words that are semantically organized. In three experiments, we show that (a) the presence of familiar semantic reference points facilitates distributional learning and (b) this effect crucially depends both on the presence of known words and the adherence of these known words to some semantic organization. Copyright © 2016 Cognitive Science Society, Inc.

  4. Ribose facilitates thallium-201 redistribution in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Perlmutter, N.S.; Wilson, R.A.; Angello, D.A.; Palac, R.T.; Lin, J.; Brown, B.G.

    1991-01-01

    To investigate whether i.v. infusion of ribose, an adenine nucleotide precursor, postischemia facilitates thallium-201 (201Tl) redistribution and improves identification of ischemic myocardium in patients with coronary artery disease (CAD), 17 patients underwent two exercise 201Tl stress tests, performed 1-2 wk apart. After immediate postexercise planar imaging, patients received either i.v. ribose (3.3 mg/kg/min x 30 min) or saline as a control. Additional imaging was performed 1 and 4 hr postexercise. Reversible defects were identified by count-profile analysis. Significantly more (nearly twice as many) reversible 201Tl defects were identified on the post-ribose images compared to the post-saline (control) images at both 1 and 4 hr postexercise (p less than 0.001). Quantitative analyses of the coronary arteriogram was available in 13 patients and confirmed that the additional reversible defects were in myocardial regions supplied by stenosed arteries. We conclude that ribose appears to facilitate 201Tl redistribution in patients with CAD and enhances identification of ischemic myocardium

  5. Application of magnetic carriers to two examples of quantitative cell analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Chen; Qian, Zhixi; Choi, Young Suk; David, Allan E. [Department of Chemical Engineering, 212 Ross Hall, Auburn University, Auburn, AL 36849 (United States); Todd, Paul, E-mail: pwtodd@hotmail.com [Techshot, Inc., 7200 Highway 150, Greenville, IN 47124 (United States); Hanley, Thomas R. [Department of Chemical Engineering, 212 Ross Hall, Auburn University, Auburn, AL 36849 (United States)

    2017-04-01

    The use of magnetophoretic mobility as a surrogate for fluorescence intensity in quantitative cell analysis was investigated. The objectives of quantitative fluorescence flow cytometry include establishing a level of labeling for the setting of parameters in fluorescence activated cell sorters (FACS) and the determination of levels of uptake of fluorescently labeled substrates by living cells. Likewise, the objectives of quantitative magnetic cytometry include establishing a level of labeling for the setting of parameters in flowing magnetic cell sorters and the determination of levels of uptake of magnetically labeled substrates by living cells. The magnetic counterpart to fluorescence intensity is magnetophoretic mobility, defined as the velocity imparted to a suspended cell per unit of magnetic ponderomotive force. A commercial velocimeter available for making this measurement was used to demonstrate both applications. Cultured Gallus lymphoma cells were immunolabeled with commercial magnetic beads and shown to have adequate magnetophoretic mobility to be separated by a novel flowing magnetic separator. Phagocytosis of starch nanoparticles having magnetic cores by cultured Chinese hamster ovary cells, a CHO line, was quantified on the basis of magnetophoretic mobility. - Highlights: • Commercial particle tracking velocimetry measures magnetophoretic mobility of labeled cells. • Magnetically labeled tumor cells were shown to have adequate mobility for capture in a specific sorter. • The kinetics of nonspecific endocytosis of magnetic nanomaterials by CHO cells was characterized. • Magnetic labeling of cells can be used like fluorescence flow cytometry for quantitative cell analysis.

  6. Quantitative analysis of scintigraphic findings in tibial stress fractures in Thoroughbred racehorses.

    Science.gov (United States)

    Valdés-Martínez, Alejandro; Seiler, Gabriela; Mai, Wilfried; Bolt, David M; Mudge, Margaret; Dukti, Sarah A; Hubert, Jeremy D

    2008-07-01

    To develop a quantitative method of interpreting tibial scintigrams of Thoroughbred racehorses with tibial stress fractures that may facilitate diagnosis of fractures and to provide prognostic information regarding future performance of affected horses. 35 Thoroughbred racehorses. Static bone-phase scintigrams of tibial stress fractures were quantitatively analyzed by use of ratios of the mean radionuclide counts per pixel in a region of interest (ROI) drawn around the area of increased uptake of radiopharmaceutical to mean counts per pixel in a second ROI drawn around an apparently normal area of the tibial diaphysis. In horses with unilateral fractures, ratios for the contralateral tibia were determined by use of 2 ROIs drawn at the same positions as the ROIs in the fractured tibia. Ratios were compared between fractured versus apparently normal tibias, between horses that returned to racing versus those that did not, and among horses with various grades of lameness. The association between ratios for fractured tibias and intervals between diagnosis and return to racing was also assessed. Mean ratio of ROIs in apparently normal tibias was 1.35 (95% confidence interval [CI], 1.21 to 1.50); that in tibias with stress fractures was 3.55 (95% CI, 2.50 to 4.60). These ratios were significantly different. None of the associations between ratios for fractured tibias and grades of lameness or performance outcomes were significant. Tibial stress fracture scintigrams can be quantitatively analyzed. A prospective study with a controlled rehabilitation period is necessary to evaluate the possible applications of this method.

  7. Quantitative 3D analysis of bone in hip osteoarthritis using clinical computed tomography.

    Science.gov (United States)

    Turmezei, Tom D; Treece, Graham M; Gee, Andrew H; Fotiadou, Anastasia F; Poole, Kenneth E S

    2016-07-01

    To assess the relationship between proximal femoral cortical bone thickness and radiological hip osteoarthritis using quantitative 3D analysis of clinical computed tomography (CT) data. Image analysis was performed on clinical CT imaging data from 203 female volunteers with a technique called cortical bone mapping (CBM). Colour thickness maps were created for each proximal femur. Statistical parametric mapping was performed to identify statistically significant differences in cortical bone thickness that corresponded with the severity of radiological hip osteoarthritis. Kellgren and Lawrence (K&L) grade, minimum joint space width (JSW) and a novel CT-based osteophyte score were also blindly assessed from the CT data. For each increase in K&L grade, cortical thickness increased by up to 25 % in distinct areas of the superolateral femoral head-neck junction and superior subchondral bone plate. For increasing severity of CT osteophytes, the increase in cortical thickness was more circumferential, involving a wider portion of the head-neck junction, with up to a 7 % increase in cortical thickness per increment in score. Results were not significant for minimum JSW. These findings indicate that quantitative 3D analysis of the proximal femur can identify changes in cortical bone thickness relevant to structural hip osteoarthritis. • CT is being increasingly used to assess bony involvement in osteoarthritis • CBM provides accurate and reliable quantitative analysis of cortical bone thickness • Cortical bone is thicker at the superior femoral head-neck with worse osteoarthritis • Regions of increased thickness co-locate with impingement and osteophyte formation • Quantitative 3D bone analysis could enable clinical disease prediction and therapy development.

  8. [Quantitative Analysis of Heavy Metals in Water with LIBS Based on Signal-to-Background Ratio].

    Science.gov (United States)

    Hu, Li; Zhao, Nan-jing; Liu, Wen-qing; Fang, Li; Zhang, Da-hai; Wang, Yin; Meng, De Shuo; Yu, Yang; Ma, Ming-jun

    2015-07-01

    There are many influence factors in the precision and accuracy of the quantitative analysis with LIBS technology. According to approximately the same characteristics trend of background spectrum and characteristic spectrum along with the change of temperature through in-depth analysis, signal-to-background ratio (S/B) measurement and regression analysis could compensate the spectral line intensity changes caused by system parameters such as laser power, spectral efficiency of receiving. Because the measurement dates were limited and nonlinear, we used support vector machine (SVM) for regression algorithm. The experimental results showed that the method could improve the stability and the accuracy of quantitative analysis of LIBS, and the relative standard deviation and average relative error of test set respectively were 4.7% and 9.5%. Data fitting method based on signal-to-background ratio(S/B) is Less susceptible to matrix elements and background spectrum etc, and provides data processing reference for real-time online LIBS quantitative analysis technology.

  9. Leadership Development Through Peer-Facilitated Simulation in Nursing Education.

    Science.gov (United States)

    Brown, Karen M; Rode, Jennifer L

    2018-01-01

    Baccalaureate nursing graduates must possess leadership skills, yet few opportunities exist to cultivate leadership abilities in a clinical environment. Peer-facilitated learning may increase the leadership skills of competence, self-confidence, self-reflection, and role modeling. Facilitating human patient simulation provides opportunities to develop leadership skills. With faculty supervision, senior baccalaureate students led small-group simulation experiences with sophomore and junior peers and then conducted subsequent debriefings. Quantitative and qualitative descriptive data allowed evaluation of students' satisfaction with this teaching innovation and whether the experience affected students' desire to take on leadership roles. Students expressed satisfaction with the peer-facilitated simulation experience and confidence in mastering the content while developing necessary skills for practice. Peer-facilitated simulation provides an opportunity for leadership development and learning. Study results can inform the development of nursing curricula to best develop the leadership skills of nursing students. [J Nurs Educ. 2018;57(1):53-57.]. Copyright 2018, SLACK Incorporated.

  10. Correlative SEM SERS for quantitative analysis of dimer nanoparticles.

    Science.gov (United States)

    Timmermans, F J; Lenferink, A T M; van Wolferen, H A G M; Otto, C

    2016-11-14

    A Raman microscope integrated with a scanning electron microscope was used to investigate plasmonic structures by correlative SEM-SERS analysis. The integrated Raman-SEM microscope combines high-resolution electron microscopy information with SERS signal enhancement from selected nanostructures with adsorbed Raman reporter molecules. Correlative analysis is performed for dimers of two gold nanospheres. Dimers were selected on the basis of SEM images from multi aggregate samples. The effect of the orientation of the dimer with respect to the polarization state of the laser light and the effect of the particle gap size on the Raman signal intensity is observed. Additionally, calculations are performed to simulate the electric near field enhancement. These simulations are based on the morphologies observed by electron microscopy. In this way the experiments are compared with the enhancement factor calculated with near field simulations and are subsequently used to quantify the SERS enhancement factor. Large differences between experimentally observed and calculated enhancement factors are regularly detected, a phenomenon caused by nanoscale differences between the real and 'simplified' simulated structures. Quantitative SERS experiments reveal the structure induced enhancement factor, ranging from ∼200 to ∼20 000, averaged over the full nanostructure surface. The results demonstrate correlative Raman-SEM microscopy for the quantitative analysis of plasmonic particles and structures, thus enabling a new analytical method in the field of SERS and plasmonics.

  11. Quantitative analysis method for niobium in lead zirconate titanate

    International Nuclear Information System (INIS)

    Hara, Hideo; Hashimoto, Toshio

    1986-01-01

    Lead zirconate titanate (PZT) is a strong dielectric ceramic having piezoelectric and pyroelectric properties, and is used most as a piezoelectric material. Also it is a main component of lead lanthanum zirconate titanate (PLZT), which is a typical electrical-optical conversion element. Since these have been developed, the various electronic parts utilizing the piezoelectric characteristics have been put in practical use. The characteristics can be set up by changing the composition of PZT and the kinds and amount of additives. Among the additives, niobium has the action to make metallic ion vacancy in crystals, and by the formation of this vacancy, to ease the movement of domain walls in crystal grains, and to increase resistivity. Accordingly, it is necessary to accurately determine the niobium content for the research and development, quality control and process control. The quantitative analysis methods for niobium used so far have respective demerits, therefore, the authors examined the quantitative analysis of niobium in PZT by using an inductively coupled plasma emission spectro-analysis apparatus which has remarkably developed recently. As the result, the method of dissolving a specimen with hydrochloric acid and hydrofluoric acid, and masking unstable lead with ethylene diamine tetraacetic acid 2 sodium and fluoride ions with boric acid was established. The apparatus, reagents, the experiment and the results are reported. (Kako, I.)

  12. Quality Assessments of Long-Term Quantitative Proteomic Analysis of Breast Cancer Xenograft Tissues

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jian-Ying; Chen, Lijun; Zhang, Bai; Tian, Yuan; Liu, Tao; Thomas, Stefani N.; Chen, Li; Schnaubelt, Michael; Boja, Emily; Hiltket, Tara; Kinsinger, Christopher; Rodriguez, Henry; Davies, Sherri; Li, Shunqiang; Snider, Jacqueline E.; Erdmann-Gilmore, Petra; Tabb, David L.; Townsend, Reid; Ellis, Matthew; Rodland, Karin D.; Smith, Richard D.; Carr, Steven A.; Zhang, Zhen; Chan, Daniel W.; Zhang, Hui

    2017-09-21

    The identification of protein biomarkers requires large-scale analysis of human specimens to achieve statistical significance. In this study, we evaluated the long-term reproducibility of an iTRAQ (isobaric tags for relative and absolute quantification) based quantitative proteomics strategy using one channel for universal normalization across all samples. A total of 307 liquid chromatography tandem mass spectrometric (LC-MS/MS) analyses were completed, generating 107 one-dimensional (1D) LC-MS/MS datasets and 8 offline two-dimensional (2D) LC-MS/MS datasets (25 fractions for each set) for human-in-mouse breast cancer xenograft tissues representative of basal and luminal subtypes. Such large-scale studies require the implementation of robust metrics to assess the contributions of technical and biological variability in the qualitative and quantitative data. Accordingly, we developed a quantification confidence score based on the quality of each peptide-spectrum match (PSM) to remove quantification outliers from each analysis. After combining confidence score filtering and statistical analysis, reproducible protein identification and quantitative results were achieved from LC-MS/MS datasets collected over a 16 month period.

  13. Absorption correction factor in X-ray fluorescent quantitative analysis

    International Nuclear Information System (INIS)

    Pimjun, S.

    1994-01-01

    An experiment on absorption correction factor in X-ray fluorescent quantitative analysis were carried out. Standard samples were prepared from the mixture of Fe 2 O 3 and tapioca flour at various concentration of Fe 2 O 3 ranging from 5% to 25%. Unknown samples were kaolin containing 3.5% to-50% of Fe 2 O 3 Kaolin samples were diluted with tapioca flour in order to reduce the absorption of FeK α and make them easy to prepare. Pressed samples with 0.150 /cm 2 and 2.76 cm in diameter, were used in the experiment. Absorption correction factor is related to total mass absorption coefficient (χ) which varied with sample composition. In known sample, χ can be calculated by conveniently the formula. However in unknown sample, χ can be determined by Emission-Transmission method. It was found that the relationship between corrected FeK α intensity and contents of Fe 2 O 3 in these samples was linear. This result indicate that this correction factor can be used to adjust the accuracy of X-ray intensity. Therefore, this correction factor is essential in quantitative analysis of elements comprising in any sample by X-ray fluorescent technique

  14. Quantitative analysis of the secretion of the MCP family of chemokines by muscle cells

    DEFF Research Database (Denmark)

    Henningsen, Jeanette; Pedersen, Bente Klarlund; Kratchmarova, Irina

    2011-01-01

    by Amino acids in Cell culture (SILAC) method for quantitative analysis resulted in the identification and generation of quantitative profiles of 59 growth factors and cytokines, including 9 classical chemokines. The members of the CC chemokine family of proteins such as monocyte chemotactic proteins 1, 2...

  15. Qualitative and quantitative reliability analysis of safety systems

    International Nuclear Information System (INIS)

    Karimi, R.; Rasmussen, N.; Wolf, L.

    1980-05-01

    A code has been developed for the comprehensive analysis of a fault tree. The code designated UNRAC (UNReliability Analysis Code) calculates the following characteristics of an input fault tree: (1) minimal cut sets; (2) top event unavailability as point estimate and/or in time dependent form; (3) quantitative importance of each component involved; and, (4) error bound on the top event unavailability. UNRAC can analyze fault trees, with any kind of gates (EOR, NAND, NOR, AND, OR), up to a maximum of 250 components and/or gates. The code is benchmarked against WAMCUT, MODCUT, KITT, BIT-FRANTIC, and PL-MODT. The results showed that UNRAC produces results more consistent with the KITT results than either BIT-FRANTIC or PL-MODT. Overall it is demonstrated that UNRAC is an efficient easy-to-use code and has the advantage of being able to do a complete fault tree analysis with this single code. Applications of fault tree analysis to safety studies of nuclear reactors are considered

  16. Facilitators and Barriers of Smokers’ Compliance with Smoking Bans in Public Places: A Systematic Review of Quantitative and Qualitative Literature

    Directory of Open Access Journals (Sweden)

    Li Zhou

    2016-12-01

    Full Text Available Background: Environmental tobacco smoke (ETS exposure is associated with an increased risk of many diseases. Many countries have ratified a national smoking ban in public places, but studies on factors related to smoking issues in public places post-ban are lacking. Aim: To identify facilitators and barriers that influenced smokers’ compliance with smoking bans in public places. Methods: Using PubMed, MEDLINE, and the Web of Science database, we conducted a systematic search of English articles published before June 2015 on factors of smokers’ compliance with the smoking bans in public places. Results: A total of 390 references were identified, among which seventeen articles (twelve quantitative studies, two qualitative studies, three mixed-method studies were included in this review. These studies focused on four types of public places including recreational venues (n = 7, hospital (n = 5, school (n = 4, and workplace (n = 1. Factors at the  individual-, interpersonal-, and organizational-level were identified: at the individual level, nicotine dependence, insufficiency of tobacco-related knowledge, and the negative attitudes towards smoking bans were the most commonly identified barriers; at the interpersonal level, the smoking behaviors of people around, close relatives, and friends’ approval were the main barriers; and at the organizational level, the main barriers were inefficient implementation of the bans and the inconvenience of the designative smoking areas. Conclusions: This synthesis of the literature provided evidence of the identified barriers and facilitators of smokers’ compliance with the smoking bans. It will be beneficial for the policy-maker to consider interventions on multiple levels of factors to overcome the barriers and enhance smokers’ compliance with the smoking bans in public places.

  17. What do parents perceive are the barriers and facilitators to accessing psychological treatment for mental health problems in children and adolescents? A systematic review of qualitative and quantitative studies.

    Science.gov (United States)

    Reardon, Tessa; Harvey, Kate; Baranowska, Magdalena; O'Brien, Doireann; Smith, Lydia; Creswell, Cathy

    2017-06-01

    A minority of children and adolescents with mental health problems access treatment. The reasons for poor rates of treatment access are not well understood. As parents are a key gatekeeper to treatment access, it is important to establish parents' views of barriers/facilitators to accessing treatment. The aims of this study are to synthesise findings from qualitative and quantitative studies that report parents' perceptions of barriers/facilitators to accessing treatment for mental health problems in children/adolescents. A systematic review and narrative synthesis were conducted. Forty-four studies were included in the review and were assessed in detail. Parental perceived barriers/facilitators relating to (1) systemic/structural issues; (2) views and attitudes towards services and treatment; (3) knowledge and understanding of mental health problems and the help-seeking process; and (4) family circumstances were identified. Findings highlight avenues for improving access to child mental health services, including increased provision that is free to service users and flexible to their needs, with opportunities to develop trusting, supportive relationships with professionals. Furthermore, interventions are required to improve parents' identification of mental health problems, reduce stigma for parents, and increase awareness of how to access services.

  18. Quantitative analysis of regional myocardial performance in coronary artery disease

    Science.gov (United States)

    Stewart, D. K.; Dodge, H. T.; Frimer, M.

    1975-01-01

    Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.

  19. Visualization and quantitative analysis of the CSF pulsatile flow with cine MR phase imaging

    International Nuclear Information System (INIS)

    Katayama, Shinji; Itoh, Takahiko; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira; Tsuchida, Shohei; Ono, Atsushi; Ikezaki, Yoshikazu; Yoshitome, Eiji.

    1991-01-01

    The visualization and the quantitative analysis of the CSF pulsatile flow were performed on ten healthy volunteers with cine MR phase imaging, a combination of the phase-contrast technique and the cardiac-gating technique. The velocities appropriate for the visualization and the quantitative analysis of the CSF pulsatile flow were from 6.0 cm/sec to 15.0 cm/sec. The applicability of this method for the quantitative analysis was proven with a steady-flow phantom. Phase images clearly demonstrated a to-and-fro motion of the CSF flow in the anterior subarachnoid space and in the posterior subarachnoid space. The flow pattern of CSF on healthy volunteers depends on the cardiac cycle. In the anterior subarachnoid space, the cephalic CSF flow continued until a 70-msec delay after the R-wave of the ECG and then reversed to caudal. At 130-190 msec, the caudal CSF flow reached its maximum velocity; thereafter it reversed again to cephalic. The same turn appeared following the phase, but then the amplitude decreased. The cephalic peaked at 370-430 msec, while the caudal peaked at 490-550 msec. The flow pattern of the CSF flow in the posterior subarachnoid space was almost identical to that in the anterior subarachnoid space. Cine MR phase imaging is thus useful for the visualization and the quantitative analysis of the CSF pulsative flow. (author)

  20. Facilitators and barriers to external cephalic version for breech presentation at term among health care providers in the Netherlands: a quantitative analysis

    NARCIS (Netherlands)

    Rosman, Ageeth N.; Vlemmix, Floortje; Beuckens, Antje; Rijnders, Marlies E.; Opmeer, Brent C.; Mol, Ben Willem J.; Kok, Marjolein; Fleuren, Margot A. H.

    2014-01-01

    guidelines recommend that external cephalic version (ECV) should be offered to all women with a fetus in breech presentation at term. However, only 50-60% of the women receive an ECV attempt. We explored the determinants (barriers and facilitators) affecting the uptake of the guidelines among

  1. Facilitators and barriers to external cephalic version for breech presentation at term among health care providers in the Netherlands: A quantitative analysis

    NARCIS (Netherlands)

    Rosman, A.N.; Vlemmix, F.; Beuckens, A.; Rijnders, M.E.; Opmeer, B.C.; Mol, B.W.J.; Kok, M.; Fleuren, M.A.H.

    2014-01-01

    OBJECTIVE: guidelines recommend that external cephalic version (ECV) should be offered to all women with a fetus in breech presentation at term. However, only 50-60% of the women receive an ECV attempt. We explored the determinants (barriers and facilitators) affecting the uptake of the guidelines

  2. Variable selection based near infrared spectroscopy quantitative and qualitative analysis on wheat wet gluten

    Science.gov (United States)

    Lü, Chengxu; Jiang, Xunpeng; Zhou, Xingfan; Zhang, Yinqiao; Zhang, Naiqian; Wei, Chongfeng; Mao, Wenhua

    2017-10-01

    Wet gluten is a useful quality indicator for wheat, and short wave near infrared spectroscopy (NIRS) is a high performance technique with the advantage of economic rapid and nondestructive test. To study the feasibility of short wave NIRS analyzing wet gluten directly from wheat seed, 54 representative wheat seed samples were collected and scanned by spectrometer. 8 spectral pretreatment method and genetic algorithm (GA) variable selection method were used to optimize analysis. Both quantitative and qualitative model of wet gluten were built by partial least squares regression and discriminate analysis. For quantitative analysis, normalization is the optimized pretreatment method, 17 wet gluten sensitive variables are selected by GA, and GA model performs a better result than that of all variable model, with R2V=0.88, and RMSEV=1.47. For qualitative analysis, automatic weighted least squares baseline is the optimized pretreatment method, all variable models perform better results than those of GA models. The correct classification rates of 3 class of 30% wet gluten content are 95.45, 84.52, and 90.00%, respectively. The short wave NIRS technique shows potential for both quantitative and qualitative analysis of wet gluten for wheat seed.

  3. Scientific aspects of urolithiasis: quantitative stone analysis and crystallization experiments

    International Nuclear Information System (INIS)

    Wandt, M.A.E.

    1986-03-01

    The theory, development and results of three quantitative analytical procedures are described and the crystallization experiments in a rotary evaporator are presented. Of the different methods of quantitative X-ray powder diffraction analyses, the 'internal standard method' and a microanalytical technique were identified as the two most useful procedures for the quantitative analysis of urinary calculi. 'Reference intensity ratios' for 6 major stone phases were determined and were used in the analysis of 20 calculi by the 'internal standard method'. Inductively coupled plasma atomic emission spectroscopic (ICP-AES) methods were also investigated, developed and used in this study. Various procedures for the digestion of calculi were tested and a mixture of HNO 3 and HC1O 4 was eventually found to be the most successful. The major elements Ca, Mg, and P in 41 calculi were determined. For the determination of trace elements, a new microwave-assisted digestion procedure was developed and used for the digestion of 100 calculi. Fluoride concentrations in two stone collections were determined using a fluoride-ion sensitive electrode and the HNO 3 /HC1O 4 digestion prodecure used for the ICP study. A series of crystallization experiments involving a standard reference artificial urine was carried out in a rotary evaporator. The effect of pH and urine composition was studied by varying the former and by including uric acid, urea, creatinine, MgO, methylene blue, chondroitin sulphate A, and fluoride in the reference solution. Crystals formed in these experiments were subjected to qualitative and semi-quantitative X-ray powder diffraction analyses. Scanning electron microscopy of several deposits was also carried out. Similar deposits to those observed in calculi were obtained with the fast evaporator. The results presented suggest that this system provides a simple, yet very useful means for studying the crystallization characteristics of urine solutions

  4. Quantitative analysis of food and feed samples with droplet digital PCR.

    Directory of Open Access Journals (Sweden)

    Dany Morisset

    Full Text Available In this study, the applicability of droplet digital PCR (ddPCR for routine analysis in food and feed samples was demonstrated with the quantification of genetically modified organisms (GMOs. Real-time quantitative polymerase chain reaction (qPCR is currently used for quantitative molecular analysis of the presence of GMOs in products. However, its use is limited for detecting and quantifying very small numbers of DNA targets, as in some complex food and feed matrices. Using ddPCR duplex assay, we have measured the absolute numbers of MON810 transgene and hmg maize reference gene copies in DNA samples. Key performance parameters of the assay were determined. The ddPCR system is shown to offer precise absolute and relative quantification of targets, without the need for calibration curves. The sensitivity (five target DNA copies of the ddPCR assay compares well with those of individual qPCR assays and of the chamber digital PCR (cdPCR approach. It offers a dynamic range over four orders of magnitude, greater than that of cdPCR. Moreover, when compared to qPCR, the ddPCR assay showed better repeatability at low target concentrations and a greater tolerance to inhibitors. Finally, ddPCR throughput and cost are advantageous relative to those of qPCR for routine GMO quantification. It is thus concluded that ddPCR technology can be applied for routine quantification of GMOs, or any other domain where quantitative analysis of food and feed samples is needed.

  5. Risk prediction, safety analysis and quantitative probability methods - a caveat

    International Nuclear Information System (INIS)

    Critchley, O.H.

    1976-01-01

    Views are expressed on the use of quantitative techniques for the determination of value judgements in nuclear safety assessments, hazard evaluation, and risk prediction. Caution is urged when attempts are made to quantify value judgements in the field of nuclear safety. Criteria are given the meaningful application of reliability methods but doubts are expressed about their application to safety analysis, risk prediction and design guidances for experimental or prototype plant. Doubts are also expressed about some concomitant methods of population dose evaluation. The complexities of new designs of nuclear power plants make the problem of safety assessment more difficult but some possible approaches are suggested as alternatives to the quantitative techniques criticized. (U.K.)

  6. A novel approach for evaluating the performance of real time quantitative loop-mediated isothermal amplification-based methods.

    Science.gov (United States)

    Nixon, Gavin J; Svenstrup, Helle F; Donald, Carol E; Carder, Caroline; Stephenson, Judith M; Morris-Jones, Stephen; Huggett, Jim F; Foy, Carole A

    2014-12-01

    Molecular diagnostic measurements are currently underpinned by the polymerase chain reaction (PCR). There are also a number of alternative nucleic acid amplification technologies, which unlike PCR, work at a single temperature. These 'isothermal' methods, reportedly offer potential advantages over PCR such as simplicity, speed and resistance to inhibitors and could also be used for quantitative molecular analysis. However there are currently limited mechanisms to evaluate their quantitative performance, which would assist assay development and study comparisons. This study uses a sexually transmitted infection diagnostic model in combination with an adapted metric termed isothermal doubling time (IDT), akin to PCR efficiency, to compare quantitative PCR and quantitative loop-mediated isothermal amplification (qLAMP) assays, and to quantify the impact of matrix interference. The performance metric described here facilitates the comparison of qLAMP assays that could assist assay development and validation activities.

  7. Examination of quantitative accuracy of PIXE analysis for atmospheric aerosol particle samples. PIXE analysis of NIST air particulate on filter media

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Sera, Koichiro

    2005-01-01

    In order to confirm accuracy of the direct analysis of filter samples containing atmospheric aerosol particles collected on a polycarbonate membrane filter by PIXE, we carried out PIXE analysis on a National Institute of Standards and Technology (NIST, USA) air particulate on filter media (SRM 2783). For 16 elements with NIST certified values determined by PIXE analysis - Na, Mg, Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb - quantitative values were 80-110% relative to NIST certified values except for Na, Al, Si and Ni. Quantitative values of Na, Al and Si were 140-170% relative to NIST certified values, which were all high, and Ni was 64%. One possible reason why the quantitative values of Na, Al and Si were higher than the NIST certified values could be the difference in the X-ray spectrum analysis method used. (author)

  8. QuASAR: quantitative allele-specific analysis of reads.

    Science.gov (United States)

    Harvey, Chris T; Moyerbrailean, Gregory A; Davis, Gordon O; Wen, Xiaoquan; Luca, Francesca; Pique-Regi, Roger

    2015-04-15

    Expression quantitative trait loci (eQTL) studies have discovered thousands of genetic variants that regulate gene expression, enabling a better understanding of the functional role of non-coding sequences. However, eQTL studies are costly, requiring large sample sizes and genome-wide genotyping of each sample. In contrast, analysis of allele-specific expression (ASE) is becoming a popular approach to detect the effect of genetic variation on gene expression, even within a single individual. This is typically achieved by counting the number of RNA-seq reads matching each allele at heterozygous sites and testing the null hypothesis of a 1:1 allelic ratio. In principle, when genotype information is not readily available, it could be inferred from the RNA-seq reads directly. However, there are currently no existing methods that jointly infer genotypes and conduct ASE inference, while considering uncertainty in the genotype calls. We present QuASAR, quantitative allele-specific analysis of reads, a novel statistical learning method for jointly detecting heterozygous genotypes and inferring ASE. The proposed ASE inference step takes into consideration the uncertainty in the genotype calls, while including parameters that model base-call errors in sequencing and allelic over-dispersion. We validated our method with experimental data for which high-quality genotypes are available. Results for an additional dataset with multiple replicates at different sequencing depths demonstrate that QuASAR is a powerful tool for ASE analysis when genotypes are not available. http://github.com/piquelab/QuASAR. fluca@wayne.edu or rpique@wayne.edu Supplementary Material is available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT): A comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87.

    Science.gov (United States)

    Pahn, Gregor; Skornitzke, Stephan; Schlemmer, Hans-Peter; Kauczor, Hans-Ulrich; Stiller, Wolfram

    2016-01-01

    Based on the guidelines from "Report 87: Radiation Dose and Image-quality Assessment in Computed Tomography" of the International Commission on Radiation Units and Measurements (ICRU), a software framework for automated quantitative image quality analysis was developed and its usability for a variety of scientific questions demonstrated. The extendable framework currently implements the calculation of the recommended Fourier image quality (IQ) metrics modulation transfer function (MTF) and noise-power spectrum (NPS), and additional IQ quantities such as noise magnitude, CT number accuracy, uniformity across the field-of-view, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of simulated lesions for a commercially available cone-beam phantom. Sample image data were acquired with different scan and reconstruction settings on CT systems from different manufacturers. Spatial resolution is analyzed in terms of edge-spread function, line-spread-function, and MTF. 3D NPS is calculated according to ICRU Report 87, and condensed to 2D and radially averaged 1D representations. Noise magnitude, CT numbers, and uniformity of these quantities are assessed on large samples of ROIs. Low-contrast resolution (CNR, SNR) is quantitatively evaluated as a function of lesion contrast and diameter. Simultaneous automated processing of several image datasets allows for straightforward comparative assessment. The presented framework enables systematic, reproducible, automated and time-efficient quantitative IQ analysis. Consistent application of the ICRU guidelines facilitates standardization of quantitative assessment not only for routine quality assurance, but for a number of research questions, e.g. the comparison of different scanner models or acquisition protocols, and the evaluation of new technology or reconstruction methods. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. The facilitation of professional values amongst student nurses in the ...

    African Journals Online (AJOL)

    The purpose of this study was to formulate guidelines to facilitate the internalisation of professional values in student nurses in order to enable them to become caring registered nurses. To realise this goal, the researcher followed a quantitative, qualitative, descriptive, exploratory and contextual approach. In Phase One of ...

  11. Facilitating Group Decision-Making: Facilitator's Subjective Theories on Group Coordination

    Directory of Open Access Journals (Sweden)

    Michaela Kolbe

    2008-10-01

    Full Text Available A key feature of group facilitation is motivating and coordinating people to perform their joint work. This paper focuses on group coordination which is a prerequisite to group effectiveness, especially in complex tasks. Decision-making in groups is a complex task that consequently needs to be coordinated by explicit rather than implicit coordination mechanisms. Based on the embedded definition that explicit coordination does not just happen but is purposely executed by individuals, we argue that individual coordination intentions and mechanisms should be taken into account. Thus far, the subjective perspective of coordination has been neglected in coordination theory, which is understandable given the difficulties in defining and measuring subjective aspects of group facilitation. We therefore conducted focused interviews with eight experts who either worked as senior managers or as experienced group facilitators and analysed their approaches to group coordination using methods of content analysis. Results show that these experts possess sophisticated mental representations of their coordination behaviour. These subjective coordination theories can be organised in terms of coordination schemes in which coordination-releasing situations are facilitated by special coordination mechanisms that, in turn, lead to the perception of specific consequences. We discuss the importance of these subjective coordination theories for effectively facilitating group decision-making and minimising process losses. URN: urn:nbn:de:0114-fqs0901287

  12. A new method for quantitative assessment of resilience engineering by PCA and NT approach: A case study in a process industry

    International Nuclear Information System (INIS)

    Shirali, Gh.A.; Mohammadfam, I.; Ebrahimipour, V.

    2013-01-01

    In recent years, resilience engineering (RE) has attracted widespread interest from industry as well as academia because it presents a new way of thinking about safety and accident. Although the concept of RE was defined scholarly in various areas, there are only few which specifically focus on how to measure RE. Therefore, there is a gap in assessing resilience by quantitative methods. This research aimed at presenting a new method for quantitative assessment of RE using questionnaire and based on principal component analysis. However, six resilience indicators, i.e., top management commitment, Just culture, learning culture, awareness and opacity, preparedness, and flexibility were chosen, and the data related to those in the 11 units of a process industry using a questionnaire was gathered. The data was analyzed based on principal component analysis (PCA) approach. The analysis also leads to determination of the score of resilience indicators and the process units. The process units were ranked using these scores. Consequently, the prescribed approach can determine the poor indicators and the process units. This is the first study that considers a quantitative assessment in RE area which is conducted through PCA. Implementation of the proposed methods would enable the managers to recognize the current weaknesses and challenges against the resilience of their system. -- Highlights: •We quantitatively measure the potential of resilience. •The results are more tangible to understand and interpret. •The method facilitates comparison of resilience state among various process units. •The method facilitates comparison of units' resilience state with the best practice

  13. Quantitative Surface Analysis by Xps (X-Ray Photoelectron Spectroscopy: Application to Hydrotreating Catalysts

    Directory of Open Access Journals (Sweden)

    Beccat P.

    1999-07-01

    Full Text Available XPS is an ideal technique to provide the chemical composition of the extreme surface of solid materials, vastly applied to the study of catalysts. In this article, we will show that a quantitative approach, based upon fundamental expression of the XPS signal, has enabled us to obtain a consistent set of response factors for the elements of the periodic table. In-depth spadework has been necessary to know precisely the transmission function of the spectrometer used at IFP. The set of response factors obtained enables to perform, on a routine basis, a quantitative analysis with approximately 20% relative accuracy, which is quite acceptable for an analysis of such a nature. While using this quantitative approach, we have developed an analytical method specific to hydrotreating catalysts that allows obtaining the sulphiding degree of molybdenum quite reliably and reproducibly. The usage of this method is illustrated by two examples for which XPS spectroscopy has provided with information sufficiently accurate and quantitative to help understand the reactivity differences between certain MoS2/Al2O3 or NiMoS/Al2O3-type hydrotreating catalysts.

  14. A borax fusion technique for quantitative X-ray fluorescence analysis

    NARCIS (Netherlands)

    van Willigen, J.H.H.G.; Kruidhof, H.; Dahmen, E.A.M.F.

    1971-01-01

    A borax fusion technique to cast glass discs for quantitative X-ray analysis is described in detail. The method is based on the “nonwetting” properties of a Pt/Au alloy towards molten borax, on the favourable composition of the flux and finally on the favourable form of the casting mould. The

  15. ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Quantitative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Halverson, Mark A.; Rosenberg, Michael I.; Wang, Weimin; Zhang, Jian; Mendon, Vrushali V.; Athalye, Rahul A.; Xie, YuLong; Hart, Reid; Goel, Supriya

    2014-03-01

    This report provides a preliminary quantitative analysis to assess whether buildings constructed according to the requirements of ANSI/ASHRAE/IES Standard 90.1-2013 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IES Standard 90.1-2010.

  16. Complex pedigree analysis to detect quantitative trait loci in dairy cattle

    NARCIS (Netherlands)

    Bink, M.C.A.M.

    1998-01-01

    In dairy cattle, many quantitative traits of economic importance show phenotypic variation. For breeding purposes the analysis of this phenotypic variation and uncovering the contribution of genetic factors is very important. Usually, the individual gene effects contributing to the

  17. Laser-induced breakdown spectroscopy for in situ qualitative and quantitative analysis of mineral ores

    International Nuclear Information System (INIS)

    Pořízka, P.; Demidov, A.; Kaiser, J.; Keivanian, J.; Gornushkin, I.; Panne, U.; Riedel, J.

    2014-01-01

    In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis. - Highlights: • Twenty seven igneous rocks were measured on different LIBS systems. • Principal component analysis (PCA) was employed for classification. • The necessity of the classification of the rock (ore) samples prior to the quantification analysis is stressed. • Classification based on the whole LIP spectra and

  18. Laser-induced breakdown spectroscopy for in situ qualitative and quantitative analysis of mineral ores

    Energy Technology Data Exchange (ETDEWEB)

    Pořízka, P. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 61669 Brno (Czech Republic); Demidov, A. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Kaiser, J. [Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 61669 Brno (Czech Republic); Keivanian, J. [Institute for Mining, Technical University Clausthal, Erzstraße 18, 38678 Clausthal-Zellerfeld (Germany); Gornushkin, I. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Panne, U. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Chemistry Department, Humboldt Univerisät zu Berlin, Brook-Taylor-Straße 2, D-12489 Berlin (Germany); Riedel, J., E-mail: jens.riedel@bam.de [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany)

    2014-11-01

    In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis. - Highlights: • Twenty seven igneous rocks were measured on different LIBS systems. • Principal component analysis (PCA) was employed for classification. • The necessity of the classification of the rock (ore) samples prior to the quantification analysis is stressed. • Classification based on the whole LIP spectra and

  19. A meta-analysis of plant facilitation in coastal dune systems: responses, regions, and research gaps.

    Science.gov (United States)

    Castanho, Camila de Toledo; Lortie, Christopher J; Zaitchik, Benjamin; Prado, Paulo Inácio

    2015-01-01

    Empirical studies in salt marshes, arid, and alpine systems support the hypothesis that facilitation between plants is an important ecological process in severe or 'stressful' environments. Coastal dunes are both abiotically stressful and frequently disturbed systems. Facilitation has been documented, but the evidence to date has not been synthesized. We did a systematic review with meta-analysis to highlight general research gaps in the study of plant interactions in coastal dunes and examine if regional and local factors influence the magnitude of facilitation in these systems. The 32 studies included in the systematic review were done in coastal dunes located in 13 countries around the world but the majority was in the temperate zone (63%). Most of the studies adopt only an observational approach to make inferences about facilitative interactions, whereas only 28% of the studies used both observational and experimental approaches. Among the factors we tested, only geographic region mediates the occurrence of facilitation more broadly in coastal dune systems. The presence of a neighbor positively influenced growth and survival in the tropics, whereas in temperate and subartic regions the effect was neutral for both response variables. We found no evidence that climatic and local factors, such as life-form and life stage of interacting plants, affect the magnitude of facilitation in coastal dunes. Overall, conclusions about plant facilitation in coastal dunes depend on the response variable measured and, more broadly, on the geographic region examined. However, the high variability and the limited number of studies, especially in tropical region, indicate we need to be cautious in the generalization of the conclusions. Anyway, coastal dunes provide an important means to explore topical issues in facilitation research including context dependency, local versus regional drivers of community structure, and the importance of gradients in shaping the outcome of net

  20. A meta-analysis of plant facilitation in coastal dune systems: responses, regions, and research gaps

    Directory of Open Access Journals (Sweden)

    Camila de Toledo Castanho

    2015-02-01

    Full Text Available Empirical studies in salt marshes, arid, and alpine systems support the hypothesis that facilitation between plants is an important ecological process in severe or ‘stressful’ environments. Coastal dunes are both abiotically stressful and frequently disturbed systems. Facilitation has been documented, but the evidence to date has not been synthesized. We did a systematic review with meta-analysis to highlight general research gaps in the study of plant interactions in coastal dunes and examine if regional and local factors influence the magnitude of facilitation in these systems. The 32 studies included in the systematic review were done in coastal dunes located in 13 countries around the world but the majority was in the temperate zone (63%. Most of the studies adopt only an observational approach to make inferences about facilitative interactions, whereas only 28% of the studies used both observational and experimental approaches. Among the factors we tested, only geographic region mediates the occurrence of facilitation more broadly in coastal dune systems. The presence of a neighbor positively influenced growth and survival in the tropics, whereas in temperate and subartic regions the effect was neutral for both response variables. We found no evidence that climatic and local factors, such as life-form and life stage of interacting plants, affect the magnitude of facilitation in coastal dunes. Overall, conclusions about plant facilitation in coastal dunes depend on the response variable measured and, more broadly, on the geographic region examined. However, the high variability and the limited number of studies, especially in tropical region, indicate we need to be cautious in the generalization of the conclusions. Anyway, coastal dunes provide an important means to explore topical issues in facilitation research including context dependency, local versus regional drivers of community structure, and the importance of gradients in shaping

  1. Quantitative phase-digital holographic microscopy: a new imaging modality to identify original cellular biomarkers of diseases

    KAUST Repository

    Marquet, P.

    2016-05-03

    Quantitative phase microscopy (QPM) has recently emerged as a powerful label-free technique in the field of living cell imaging allowing to non-invasively measure with a nanometric axial sensitivity cell structure and dynamics. Since the phase retardation of a light wave when transmitted through the observed cells, namely the quantitative phase signal (QPS), is sensitive to both cellular thickness and intracellular refractive index related to the cellular content, its accurate analysis allows to derive various cell parameters and monitor specific cell processes, which are very likely to identify new cell biomarkers. Specifically, quantitative phase-digital holographic microscopy (QP-DHM), thanks to its numerical flexibility facilitating parallelization and automation processes, represents an appealing imaging modality to both identify original cellular biomarkers of diseases as well to explore the underlying pathophysiological processes.

  2. Quantitative ferromagnetic resonance analysis of CD 133 stem cells labeled with iron oxide nanoparticles

    International Nuclear Information System (INIS)

    Gamarra, L F; Pavon, L F; Marti, L C; Moreira-Filho, C A; Amaro, E Jr; Pontuschka, W M; Mamani, J B; Costa-Filho, A J; Vieira, E D

    2008-01-01

    The aim of this work is to provide a quantitative method for analysis of the concentration of superparamagnetic iron oxide nanoparticles (SPION), determined by means of ferromagnetic resonance (FMR), with the nanoparticles coupled to a specific antibody (AC 133), and thus to express the antigenic labeling evidence for the stem cells CD 133 + . The FMR efficiency and sensitivity were proven adequate for detecting and quantifying the low amounts of iron content in the CD 133 + cells (∼6.16 x 10 5 pg in the volume of 2 μl containing 4.5 x 10 11 SPION). The quantitative method led to the result of 1.70 x 10 -13 mol of Fe (9.5 pg), or 7.0 x 10 6 nanoparticles per cell. For the quantification analysis via the FMR technique it was necessary to carry out a preliminary quantitative visualization of iron oxide-labeled cells in order to ensure that the nanoparticles coupled to the antibodies are indeed tied to the antigen at the stem cell surface and that the cellular morphology was conserved, as proof of the validity of this method. The quantitative analysis by means of FMR is necessary for determining the signal intensity for the study of molecular imaging by means of magnetic resonance imaging (MRI)

  3. Review of Department of Defense Education Activity (DODEA) Schools. Volume II: Quantitative Analysis of Educational Quality

    National Research Council Canada - National Science Library

    Anderson, Lowell

    2000-01-01

    This volume compiles, and presents in integrated form, IDA's quantitative analysis of educational quality provided by DoD's dependent schools, It covers the quantitative aspects of volume I in greater...

  4. Facilitators of prenatal care access in rural Appalachia.

    Science.gov (United States)

    Phillippi, Julia C; Myers, Carole R; Schorn, Mavis N

    2014-12-01

    There are many providers and models of prenatal care, some more effective than others. However, quantitative research alone cannot determine the reasons beneficial models of care improve health outcomes. Perspectives of women receiving care from effective clinics can provide valuable insight. We surveyed 29 women receiving care at a rural, Appalachian birth center in the United States with low rates of preterm birth. Semi-structured interviews and demographic questionnaires were analyzed using conventional qualitative content analysis of manifest content. Insurance was the most common facilitator of prenatal access. Beneficial characteristics of the provider and clinic included: personalized care, unrushed visits, varied appointment times, short waits, and choice in the type and location of care. There is a connection between compassionate and personalized care and positive birth outcomes. Women were willing to overcome barriers to access care that met their needs. To facilitate access to prenatal care and decrease health disparities, healthcare planners, and policy makers need to ensure all women can afford to access prenatal care and allow women a choice in their care provider. Clinic administrators should create a welcoming clinic environment with minimal wait time. Unrushed, woman-centered prenatal visits can increase access to and motivation for care and are easily integrated into prenatal care with minimal cost. Copyright © 2014 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  5. Quantitative analysis of intermolecular interactions in orthorhombic rubrene

    Directory of Open Access Journals (Sweden)

    Venkatesha R. Hathwar

    2015-09-01

    Full Text Available Rubrene is one of the most studied organic semiconductors to date due to its high charge carrier mobility which makes it a potentially applicable compound in modern electronic devices. Previous electronic device characterizations and first principles theoretical calculations assigned the semiconducting properties of rubrene to the presence of a large overlap of the extended π-conjugated core between molecules. We present here the electron density distribution in rubrene at 20 K and at 100 K obtained using a combination of high-resolution X-ray and neutron diffraction data. The topology of the electron density and energies of intermolecular interactions are studied quantitatively. Specifically, the presence of Cπ...Cπ interactions between neighbouring tetracene backbones of the rubrene molecules is experimentally confirmed from a topological analysis of the electron density, Non-Covalent Interaction (NCI analysis and the calculated interaction energy of molecular dimers. A significant contribution to the lattice energy of the crystal is provided by H—H interactions. The electron density features of H—H bonding, and the interaction energy of molecular dimers connected by H—H interaction clearly demonstrate an importance of these weak interactions in the stabilization of the crystal structure. The quantitative nature of the intermolecular interactions is virtually unchanged between 20 K and 100 K suggesting that any changes in carrier transport at these low temperatures would have a different origin. The obtained experimental results are further supported by theoretical calculations.

  6. Quantitative analysis of tellurium in simple substance sulfur

    International Nuclear Information System (INIS)

    Arikawa, Yoshiko

    1976-01-01

    The MIBK extraction-bismuthiol-2 absorptiometric method for the quantitative analysis of tellurium was studied. The method and its limitation were compared with the atomic absorption method. The period of time required to boil the solution in order to decompose excess hydrogen peroxide and to reduce tellurium from 6 valance to 4 valance was examined. As a result of experiment, the decomposition was fast in the alkaline solution. It takes 30 minutes with alkaline solution and 40 minutes with acid solution to indicate constant absorption. A method of analyzing the sample containing tellurium less than 5 ppm was studied. The experiment revealed that the sample containing a very small amount of tellurium can be analyzed when concentration by extraction is carried out for the sample solutions which are divided into one gram each because it is difficult to treat several grams of the sample at one time. This method also is suitable for the quantitative analysis of selenium. This method showed good addition effect and reproducibility within the relative error of 5%. The comparison between the calibration curve of the standard solution of tellurium 4 subjected to the reaction with bismuthiol-2 and the calibration curve obtained from the extraction of tellurium 4 with MIBK indicated that the extraction is perfect. The result by bismuthiol-2 method and that by atom absorption method coincided quite well on the same sample. (Iwakiri, K.)

  7. A semi-quantitative model for risk appreciation and risk weighing

    DEFF Research Database (Denmark)

    Bos, Peter M.J.; Boon, Polly E.; van der Voet, Hilko

    2009-01-01

    Risk managers need detailed information on (1) the type of effect, (2) the size (severity) of the expected effect(s) and (3) the fraction of the population at risk to decide on well-balanced risk reduction measures. A previously developed integrated probabilistic risk assessment (IPRA) model...... provides quantitative information on these three parameters. A semi-quantitative tool is presented that combines information on these parameters into easy-readable charts that will facilitate risk evaluations of exposure situations and decisions on risk reduction measures. This tool is based on a concept...... detailed information on the estimated health impact in a given exposure situation. These graphs will facilitate the discussions on appropriate risk reduction measures to be taken....

  8. Quantitative analysis of titanium concentration using calibration-free laser-induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Zaitun; Prasetyo, S.; Suliyanti, M. M.; Isnaeni; Herbani, Y.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) can be used for quantitative and qualitative analysis. Calibration-free LIBS (CF-LIBS) is a method to quantitatively analyze concentration of elements in a sample in local thermodynamic equilibrium conditions without using available matrix-matched calibration. In this study, we apply CF-LIBS for quantitative analysis of Ti in TiO2 sample. TiO2 powder sample was mixed with polyvinyl alcohol and formed into pellets. An Nd:YAG pulsed laser at a wavelength of 1064 nm was focused onto the sample to generate plasma. The spectrum of plasma was recorded using spectrophotometer then compared to NIST spectral line to determine energy levels and other parameters. The value of plasma temperature obtained using Boltzmann plot is 8127.29 K and electron density from calculation is 2.49×1016 cm-3. Finally, the concentration of Ti in TiO2 sample from this study is 97% that is in proximity with the sample certificate.

  9. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    Science.gov (United States)

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  10. Quantitative research.

    Science.gov (United States)

    Watson, Roger

    2015-04-01

    This article describes the basic tenets of quantitative research. The concepts of dependent and independent variables are addressed and the concept of measurement and its associated issues, such as error, reliability and validity, are explored. Experiments and surveys – the principal research designs in quantitative research – are described and key features explained. The importance of the double-blind randomised controlled trial is emphasised, alongside the importance of longitudinal surveys, as opposed to cross-sectional surveys. Essential features of data storage are covered, with an emphasis on safe, anonymous storage. Finally, the article explores the analysis of quantitative data, considering what may be analysed and the main uses of statistics in analysis.

  11. Activated sludge characterization through microscopy: A review on quantitative image analysis and chemometric techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Daniela P. [IBB-Institute for Biotechnology and Bioengineering, Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga (Portugal); Amaral, A. Luís [IBB-Institute for Biotechnology and Bioengineering, Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga (Portugal); Instituto Politécnico de Coimbra, ISEC, DEQB, Rua Pedro Nunes, Quinta da Nora, 3030-199 Coimbra (Portugal); Ferreira, Eugénio C., E-mail: ecferreira@deb.uminho.pt [IBB-Institute for Biotechnology and Bioengineering, Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga (Portugal)

    2013-11-13

    Graphical abstract: -- Highlights: •Quantitative image analysis shows potential to monitor activated sludge systems. •Staining techniques increase the potential for detection of operational problems. •Chemometrics combined with quantitative image analysis is valuable for process monitoring. -- Abstract: In wastewater treatment processes, and particularly in activated sludge systems, efficiency is quite dependent on the operating conditions, and a number of problems may arise due to sludge structure and proliferation of specific microorganisms. In fact, bacterial communities and protozoa identification by microscopy inspection is already routinely employed in a considerable number of cases. Furthermore, quantitative image analysis techniques have been increasingly used throughout the years for the assessment of aggregates and filamentous bacteria properties. These procedures are able to provide an ever growing amount of data for wastewater treatment processes in which chemometric techniques can be a valuable tool. However, the determination of microbial communities’ properties remains a current challenge in spite of the great diversity of microscopy techniques applied. In this review, activated sludge characterization is discussed highlighting the aggregates structure and filamentous bacteria determination by image analysis on bright-field, phase-contrast, and fluorescence microscopy. An in-depth analysis is performed to summarize the many new findings that have been obtained, and future developments for these biological processes are further discussed.

  12. A quantitative analysis of the causes of the global climate change research distribution

    DEFF Research Database (Denmark)

    Pasgaard, Maya; Strange, Niels

    2013-01-01

    investigates whether the need for knowledge on climate changes in the most vulnerable regions of the world is met by the supply of knowledge measured by scientific research publications from the last decade. A quantitative analysis of more than 15,000 scientific publications from 197 countries investigates...... the poorer, fragile and more vulnerable regions of the world. A quantitative keywords analysis of all publications shows that different knowledge domains and research themes dominate across regions, reflecting the divergent global concerns in relation to climate change. In general, research on climate change...... the distribution of climate change research and the potential causes of this distribution. More than 13 explanatory variables representing vulnerability, geographical, demographical, economical and institutional indicators are included in the analysis. The results show that the supply of climate change knowledge...

  13. Computer aided approach to qualitative and quantitative common cause failure analysis for complex systems

    International Nuclear Information System (INIS)

    Cate, C.L.; Wagner, D.P.; Fussell, J.B.

    1977-01-01

    Common cause failure analysis, also called common mode failure analysis, is an integral part of a complete system reliability analysis. Existing methods of computer aided common cause failure analysis are extended by allowing analysis of the complex systems often encountered in practice. The methods aid in identifying potential common cause failures and also address quantitative common cause failure analysis

  14. [Device for quantitative analysis of perception and pain sensation].

    Science.gov (United States)

    Arita, Hideko; Kato, Jitsu; Ogawa, Setsuro; Hanaoka, Kazuo

    2014-07-01

    The article describes an analysing device that measures the perception and intensity of pain quantitatively. While it is not necessarily true that psychological aspect is totally irrelevant to pain measurement, this device is remarkable in that it is capable of measuring the intensity of pain felt by the patient more objectively by using electric stimuli. The feature of this device is that it uses a non-pain heteresthesia for measuring the intensity of pain. The device is compact, light-weight, and portable. Unlike VAS that requires only a scale, the device requires a person to carry out the measurement. Nevertheless, as the National Health Insurance (NHI) coverage has been approved, introduction of the device may be facilitated in terms of budget for the purchase and labor. The device is useful to better understand not only the intensity of pain but also the pathological conditions, resulting in more appropriate treatment, by (1) comparing degree of pain or VAS values taken by a multicenter study with those of a patient; (2) using both degree of pain and VAS; and (3) multiple measurements of degree of pain and VAS in one case.

  15. Quantitative phase analysis of a highly textured industrial sample using a Rietveld profile analysis

    International Nuclear Information System (INIS)

    Shin, Eunjoo; Huh, Moo-Young; Seong, Baek-Seok; Lee, Chang-Hee

    2001-01-01

    For the quantitative phase analysis on highly textured two-phase materials, samples with known weight fractions of zirconium and aluminum were prepared. Strong texture components prevailed in both zirconium and aluminum sheet. The diffraction patterns of samples were measured by the neutron and refined by the Rietveld method. The preferred orientation correction of diffraction patterns was carried out by means of recalculated pole figures from the ODF. The present Rietveld analysis of various samples with different weight fractions showed that the absolute error of the calculated weight fractions was less than 7.1%. (author)

  16. The Quantitative Analysis of Chennai Automotive Industry Cluster

    Science.gov (United States)

    Bhaskaran, Ethirajan

    2016-07-01

    Chennai, also called as Detroit of India due to presence of Automotive Industry producing over 40 % of the India's vehicle and components. During 2001-2002, the Automotive Component Industries (ACI) in Ambattur, Thirumalizai and Thirumudivakkam Industrial Estate, Chennai has faced problems on infrastructure, technology, procurement, production and marketing. The objective is to study the Quantitative Performance of Chennai Automotive Industry Cluster before (2001-2002) and after the CDA (2008-2009). The methodology adopted is collection of primary data from 100 ACI using quantitative questionnaire and analyzing using Correlation Analysis (CA), Regression Analysis (RA), Friedman Test (FMT), and Kruskall Wallis Test (KWT).The CA computed for the different set of variables reveals that there is high degree of relationship between the variables studied. The RA models constructed establish the strong relationship between the dependent variable and a host of independent variables. The models proposed here reveal the approximate relationship in a closer form. KWT proves, there is no significant difference between three locations clusters with respect to: Net Profit, Production Cost, Marketing Costs, Procurement Costs and Gross Output. This supports that each location has contributed for development of automobile component cluster uniformly. The FMT proves, there is no significant difference between industrial units in respect of cost like Production, Infrastructure, Technology, Marketing and Net Profit. To conclude, the Automotive Industries have fully utilized the Physical Infrastructure and Centralised Facilities by adopting CDA and now exporting their products to North America, South America, Europe, Australia, Africa and Asia. The value chain analysis models have been implemented in all the cluster units. This Cluster Development Approach (CDA) model can be implemented in industries of under developed and developing countries for cost reduction and productivity

  17. Barriers and facilitators to end-of-life communication in advanced chronic organ failure.

    Science.gov (United States)

    Van den Heuvel, Liza Amc; Spruit, Martijn A; Schols, Jos Mga; Hoving, Ciska; Wouters, Emiel Fm; Janssen, Daisy Ja

    2016-05-01

    The aim of this quantitative, cross-sectional study was to identify barriers and facilitators to end-of-life communication experienced by family caregivers of patients with advanced chronic organ failure and to examine agreement in barriers and facilitators between family caregivers and patients. Patients and family caregivers were interviewed using the barriers and facilitators questionnaire. Agreement was determined using intraclass correlation coefficients for continuous variables and Cohen's kappa for categorical variables. A total of 158 patients and family caregiver dyads were included. The most important barriers for family caregivers were related to uncertainty about expected care and focus on staying alive instead of dying. The facilitators were related to trust in and competence of their physician and earlier experiences with death in their (social) environment. For most barriers and facilitators, agreement between patients and family caregivers was fair to moderate. Differences in barriers and facilitators between patients and family caregivers ask for an individual approach to facilitate end-of-life communication.

  18. Multivariate reference technique for quantitative analysis of fiber-optic tissue Raman spectroscopy.

    Science.gov (United States)

    Bergholt, Mads Sylvest; Duraipandian, Shiyamala; Zheng, Wei; Huang, Zhiwei

    2013-12-03

    We report a novel method making use of multivariate reference signals of fused silica and sapphire Raman signals generated from a ball-lens fiber-optic Raman probe for quantitative analysis of in vivo tissue Raman measurements in real time. Partial least-squares (PLS) regression modeling is applied to extract the characteristic internal reference Raman signals (e.g., shoulder of the prominent fused silica boson peak (~130 cm(-1)); distinct sapphire ball-lens peaks (380, 417, 646, and 751 cm(-1))) from the ball-lens fiber-optic Raman probe for quantitative analysis of fiber-optic Raman spectroscopy. To evaluate the analytical value of this novel multivariate reference technique, a rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe is used for in vivo oral tissue Raman measurements (n = 25 subjects) under 785 nm laser excitation powers ranging from 5 to 65 mW. An accurate linear relationship (R(2) = 0.981) with a root-mean-square error of cross validation (RMSECV) of 2.5 mW can be obtained for predicting the laser excitation power changes based on a leave-one-subject-out cross-validation, which is superior to the normal univariate reference method (RMSE = 6.2 mW). A root-mean-square error of prediction (RMSEP) of 2.4 mW (R(2) = 0.985) can also be achieved for laser power prediction in real time when we applied the multivariate method independently on the five new subjects (n = 166 spectra). We further apply the multivariate reference technique for quantitative analysis of gelatin tissue phantoms that gives rise to an RMSEP of ~2.0% (R(2) = 0.998) independent of laser excitation power variations. This work demonstrates that multivariate reference technique can be advantageously used to monitor and correct the variations of laser excitation power and fiber coupling efficiency in situ for standardizing the tissue Raman intensity to realize quantitative analysis of tissue Raman measurements in vivo, which is particularly appealing in

  19. Three-way methods for the analysis of qualitative and quantitative two-way data.

    NARCIS (Netherlands)

    Kiers, Hendrik Albert Lambertus

    1989-01-01

    A problem often occurring in exploratory data analysis is how to summarize large numbers of variables in terms of a smaller number of dimensions. When the variables are quantitative, one may resort to Principal Components Analysis (PCA). When qualitative (categorical) variables are involved, one may

  20. Integration of Qualitative and Quantitative Methods: Building and Interpreting Clusters from Grounded Theory and Discourse Analysis

    Directory of Open Access Journals (Sweden)

    Aldo Merlino

    2007-01-01

    Full Text Available Qualitative methods present a wide spectrum of application possibilities as well as opportunities for combining qualitative and quantitative methods. In the social sciences fruitful theoretical discussions and a great deal of empirical research have taken place. This article introduces an empirical investigation which demonstrates the logic of combining methodologies as well as the collection and interpretation, both sequential as simultaneous, of qualitative and quantitative data. Specifically, the investigation process will be described, beginning with a grounded theory methodology and its combination with the techniques of structural semiotics discourse analysis to generate—in a first phase—an instrument for quantitative measuring and to understand—in a second phase—clusters obtained by quantitative analysis. This work illustrates how qualitative methods allow for the comprehension of the discursive and behavioral elements under study, and how they function as support making sense of and giving meaning to quantitative data. URN: urn:nbn:de:0114-fqs0701219

  1. Winston-Lutz Test: A quantitative analysis

    International Nuclear Information System (INIS)

    Pereira, Aline Garcia; Nandi, Dorival Menegaz; Saraiva, Crystian Wilian Chagas

    2017-01-01

    Objective: Describe a method of quantitative analysis for the Winston-Lutz test. Materials and methods The research is a qualitative exploratory study. The materials used were: portal film; Winston- Lutz test tools and Omni Pro software. Sixteen portal films were used as samples and were analyzed by five different technicians to measure the deviation between the radiation isocenters and mechanic. Results: Among the results were identified two combinations with offset values greater than 1 mm. In addition, when compared the method developed with the previously studied, it was observed that the data obtained are very close, with the maximum percentage deviation of 32.5%, which demonstrates its efficacy in reducing dependence on the performer. Conclusion: The results show that the method is reproducible and practical, which constitutes one of the fundamental factors for its implementation. (author)

  2. A novel approach for evaluating the performance of real time quantitative loop-mediated isothermal amplification-based methods

    Directory of Open Access Journals (Sweden)

    Gavin J. Nixon

    2014-12-01

    Full Text Available Molecular diagnostic measurements are currently underpinned by the polymerase chain reaction (PCR. There are also a number of alternative nucleic acid amplification technologies, which unlike PCR, work at a single temperature. These ‘isothermal’ methods, reportedly offer potential advantages over PCR such as simplicity, speed and resistance to inhibitors and could also be used for quantitative molecular analysis. However there are currently limited mechanisms to evaluate their quantitative performance, which would assist assay development and study comparisons. This study uses a sexually transmitted infection diagnostic model in combination with an adapted metric termed isothermal doubling time (IDT, akin to PCR efficiency, to compare quantitative PCR and quantitative loop-mediated isothermal amplification (qLAMP assays, and to quantify the impact of matrix interference. The performance metric described here facilitates the comparison of qLAMP assays that could assist assay development and validation activities.

  3. A scanning electron microscope method for automated, quantitative analysis of mineral matter in coal

    Energy Technology Data Exchange (ETDEWEB)

    Creelman, R.A.; Ward, C.R. [R.A. Creelman and Associates, Epping, NSW (Australia)

    1996-07-01

    Quantitative mineralogical analysis has been carried out in a series of nine coal samples from Australia, South Africa and China using a newly-developed automated image analysis system coupled to a scanning electron microscopy. The image analysis system (QEM{asterisk}SEM) gathers X-ray spectra and backscattered electron data from a number of points on a conventional grain-mount polished section under the SEM, and interprets the data from each point in mineralogical terms. The cumulative data in each case was integrated to provide a volumetric modal analysis of the species present in the coal samples, expressed as percentages of the respective coals` mineral matter. Comparison was made of the QEM{asterisk}SEM results to data obtained from the same samples using other methods of quantitative mineralogical analysis, namely X-ray diffraction of the low-temperature oxygen-plasma ash and normative calculation from the (high-temperature) ash analysis and carbonate CO{sub 2} data. Good agreement was obtained from all three methods for quartz in the coals, and also for most of the iron-bearing minerals. The correlation between results from the different methods was less strong, however, for individual clay minerals, or for minerals such as calcite, dolomite and phosphate species that made up only relatively small proportions of the mineral matter. The image analysis approach, using the electron microscope for mineralogical studies, has significant potential as a supplement to optical microscopy in quantitative coal characterisation. 36 refs., 3 figs., 4 tabs.

  4. Quantitative analysis technique for Xenon in PWR spent fuel by using WDS

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, H. M.; Kim, D. S.; Seo, H. S.; Ju, J. S.; Jang, J. N.; Yang, Y. S.; Park, S. D. [KAERI, Daejeon (Korea, Republic of)

    2012-01-15

    This study includes three processes. First, a peak centering of the X-ray line was performed after a diffraction for Xenon La1 line was installed. Xe La1 peak was identified by a PWR spent fuel sample. Second, standard intensities of Xe was obtained by interpolation of the La1 intensities from a series of elements on each side of xenon. And then Xe intensities across the radial direction of a PWR spent fuel sample were measured by WDS-SEM. Third, the electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to do matrix correction of a PWR spent fuel sample. Finally, the method and the procedure for local quantitative analysis of Xenon was developed in this study.

  5. Quantitative analysis technique for Xenon in PWR spent fuel by using WDS

    International Nuclear Information System (INIS)

    Kwon, H. M.; Kim, D. S.; Seo, H. S.; Ju, J. S.; Jang, J. N.; Yang, Y. S.; Park, S. D.

    2012-01-01

    This study includes three processes. First, a peak centering of the X-ray line was performed after a diffraction for Xenon La1 line was installed. Xe La1 peak was identified by a PWR spent fuel sample. Second, standard intensities of Xe was obtained by interpolation of the La1 intensities from a series of elements on each side of xenon. And then Xe intensities across the radial direction of a PWR spent fuel sample were measured by WDS-SEM. Third, the electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to do matrix correction of a PWR spent fuel sample. Finally, the method and the procedure for local quantitative analysis of Xenon was developed in this study

  6. Hair analysis in toxicological investigation of drug-facilitated crimes in Denmark over a 8-year period.

    Science.gov (United States)

    Wang, Xin; Johansen, Sys Stybe; Nielsen, Marie Katrine Klose; Linnet, Kristian

    2018-04-01

    Hair can serve as a specimen for identifying past drug exposure. Segmental hair analysis may differentiate a single exposure from chronic use. Consequently, segmental hair analysis is useful for disclosing a single drug ingestion, as well as for determining repeated exposures in drug-facilitated crimes (DFCs). This paper presents an overview of toxicological investigations that have used hair analysis in DFC cases from 2009 to 2016 in Denmark. Hair concentrations were determined for 24 DFC-related drugs and metabolites, including benzodiazepines and other hypnotics, antihistamines, opioid analgesics, antipsychotics, barbiturates, and illicit drugs from DFC cases. Drug detection in hair in DFC cases following a single or few intakes of chlorprothixene, codeine, diphenhydramine, oxazepam, oxycodone, promethazine, and phenobarbital is reported for the first time in forensic toxicology. A literature review on concentrations in the published DFC-related hair cases and on concentrations in hair of these substances after single and multiple doses is included. These cases demonstrate the value of segmental hair analysis in DFCs and facilitate future interpretations of results. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    Science.gov (United States)

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  8. A novel iris transillumination grading scale allowing flexible assessment with quantitative image analysis and visual matching.

    Science.gov (United States)

    Wang, Chen; Brancusi, Flavia; Valivullah, Zaheer M; Anderson, Michael G; Cunningham, Denise; Hedberg-Buenz, Adam; Power, Bradley; Simeonov, Dimitre; Gahl, William A; Zein, Wadih M; Adams, David R; Brooks, Brian

    2018-01-01

    To develop a sensitive scale of iris transillumination suitable for clinical and research use, with the capability of either quantitative analysis or visual matching of images. Iris transillumination photographic images were used from 70 study subjects with ocular or oculocutaneous albinism. Subjects represented a broad range of ocular pigmentation. A subset of images was subjected to image analysis and ranking by both expert and nonexpert reviewers. Quantitative ordering of images was compared with ordering by visual inspection. Images were binned to establish an 8-point scale. Ranking consistency was evaluated using the Kendall rank correlation coefficient (Kendall's tau). Visual ranking results were assessed using Kendall's coefficient of concordance (Kendall's W) analysis. There was a high degree of correlation among the image analysis, expert-based and non-expert-based image rankings. Pairwise comparisons of the quantitative ranking with each reviewer generated an average Kendall's tau of 0.83 ± 0.04 (SD). Inter-rater correlation was also high with Kendall's W of 0.96, 0.95, and 0.95 for nonexpert, expert, and all reviewers, respectively. The current standard for assessing iris transillumination is expert assessment of clinical exam findings. We adapted an image-analysis technique to generate quantitative transillumination values. Quantitative ranking was shown to be highly similar to a ranking produced by both expert and nonexpert reviewers. This finding suggests that the image characteristics used to quantify iris transillumination do not require expert interpretation. Inter-rater rankings were also highly similar, suggesting that varied methods of transillumination ranking are robust in terms of producing reproducible results.

  9. Quantitative security analysis for programs with low input and noisy output

    NARCIS (Netherlands)

    Ngo, Minh Tri; Huisman, Marieke

    Classical quantitative information flow analysis often considers a system as an information-theoretic channel, where private data are the only inputs and public data are the outputs. However, for systems where an attacker is able to influence the initial values of public data, these should also be

  10. Quantitative multiphase analysis of archaeological bronzes by neutron diffraction

    CERN Document Server

    Siano, S; Celli, M; Pini, R; Salimbeni, R; Zoppi, M; Kockelmann, W A; Iozzo, M; Miccio, M; Moze, O

    2002-01-01

    In this paper, we report the first investigation on the potentials of neutron diffraction to characterize archaeological bronze artifacts. The preliminary feasibility of phase and structural analysis was demonstrated on standardised specimens with a typical bronze alloy composition. These were realised through different hardening and annealing cycles, simulating possible ancient working techniques. The Bragg peak widths that resulted were strictly dependent on the working treatment, thus providing an important analytical element to investigate ancient making techniques. The diagnostic criteria developed on the standardised specimens were then applied to study two Etruscan museum pieces. Quantitative multiphase analysis by Rietveld refinement of the diffraction patterns was successfully demonstrated. Furthermore, the analysis of patterns associated with different artifact elements also yielded evidence for some peculiar perspective of the neutron diffraction diagnostics in archeometric applications. (orig.)

  11. Quantitative ferromagnetic resonance analysis of CD 133 stem cells labeled with iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Gamarra, L F; Pavon, L F; Marti, L C; Moreira-Filho, C A; Amaro, E Jr [Instituto Israelita de Ensino e Pesquisa Albert Einstein, IIEPAE, Sao Paulo 05651-901 (Brazil); Pontuschka, W M; Mamani, J B [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo 05315-970 (Brazil); Costa-Filho, A J; Vieira, E D [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Sao Carlos 13560-970 (Brazil)], E-mail: lgamarra@einstein.br

    2008-05-21

    The aim of this work is to provide a quantitative method for analysis of the concentration of superparamagnetic iron oxide nanoparticles (SPION), determined by means of ferromagnetic resonance (FMR), with the nanoparticles coupled to a specific antibody (AC 133), and thus to express the antigenic labeling evidence for the stem cells CD 133{sup +}. The FMR efficiency and sensitivity were proven adequate for detecting and quantifying the low amounts of iron content in the CD 133{sup +} cells ({approx}6.16 x 10{sup 5} pg in the volume of 2 {mu}l containing 4.5 x 10{sup 11} SPION). The quantitative method led to the result of 1.70 x 10{sup -13} mol of Fe (9.5 pg), or 7.0 x 10{sup 6} nanoparticles per cell. For the quantification analysis via the FMR technique it was necessary to carry out a preliminary quantitative visualization of iron oxide-labeled cells in order to ensure that the nanoparticles coupled to the antibodies are indeed tied to the antigen at the stem cell surface and that the cellular morphology was conserved, as proof of the validity of this method. The quantitative analysis by means of FMR is necessary for determining the signal intensity for the study of molecular imaging by means of magnetic resonance imaging (MRI)

  12. Quantitative analysis of rat Ig (sub)classes binding to cell surface antigens

    International Nuclear Information System (INIS)

    Nilsson, R.; Brodin, T.; Sjoegren, H.-O.

    1982-01-01

    An indirect 125 I-labeled protein A assay for detection of cell surface-bound rat immunoglobulins is presented. The assay is quantitative and rapid and detects as little as 1 ng of cell surface-bound Ig. It discriminates between antibodies belonging to different IgG subclasses, IgM and IgA. The authors describe the production and specificity control of the reagents used and show that the test can be used for quantitative analysis. A large number of sera from untreated rats are tested to evaluate the frequency of falsely positive responses and variation due to age, sex and strain of rat. With this test it is relatively easy to quantitate the binding of classes and subclasses of rat immunoglobulins in a small volume (6 μl) of untreated serum. (Auth.)

  13. Digital Holography, a metrological tool for quantitative analysis: Trends and future applications

    Science.gov (United States)

    Paturzo, Melania; Pagliarulo, Vito; Bianco, Vittorio; Memmolo, Pasquale; Miccio, Lisa; Merola, Francesco; Ferraro, Pietro

    2018-05-01

    A review on the last achievements of Digital Holography is reported in this paper, showing that this powerful method can be a key metrological tool for the quantitative analysis and non-invasive inspection of a variety of materials, devices and processes. Nowadays, its range of applications has been greatly extended, including the study of live biological matter and biomedical applications. This paper overviews the main progresses and future perspectives of digital holography, showing new optical configurations and investigating the numerical issues to be tackled for the processing and display of quantitative data.

  14. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    El Haddad, J. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Villot-Kadri, M.; Ismaël, A.; Gallou, G. [IVEA Solution, Centre Scientifique d' Orsay, Bât 503, 91400 Orsay (France); Michel, K.; Bruyère, D.; Laperche, V. [BRGM, Service Métrologie, Monitoring et Analyse, 3 avenue Claude Guillemin, B.P 36009, 45060 Orléans Cedex (France); Canioni, L. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Bousquet, B., E-mail: bruno.bousquet@u-bordeaux1.fr [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France)

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced.

  15. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    El Haddad, J.; Villot-Kadri, M.; Ismaël, A.; Gallou, G.; Michel, K.; Bruyère, D.; Laperche, V.; Canioni, L.; Bousquet, B.

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced

  16. A qualitative theory guided analysis of stroke survivors' perceived barriers and facilitators to physical activity.

    Science.gov (United States)

    Nicholson, Sarah L; Donaghy, Marie; Johnston, Marie; Sniehotta, Falko F; van Wijck, Frederike; Johnston, Derek; Greig, Carolyn; McMurdo, Marion E T; Mead, Gillian

    2014-01-01

    After stroke, physical activity and physical fitness levels are low, impacting on health, activity and participation. It is unclear how best to support stroke survivors to increase physical activity. Little is known about the barriers and facilitators to physical activity after stroke. Thus, our aim was to explore stroke survivors' perceived barriers and facilitators to physical activity. Semi-structured interviews with 13 ambulatory stroke survivors exploring perceived barriers and facilitators to physical activity post stroke were conducted in participants' homes, audio-recorded and transcribed verbatim. The Theoretical Domains Framework (TDF) informed content analysis of the interview transcripts. Data saturation was reached after interviews with 13 participants (median age of 76 years (inter-quartile range (IQR) = 69-83 years). The median time since stroke was 345 d (IQR = 316-366 d). The most commonly reported TDF domains were "beliefs about capabilities", "environmental context and resources" and "social influence". The most commonly reported perceived motivators were: social interaction, beliefs of benefits of exercise, high self-efficacy and the necessity of routine behaviours. The most commonly reported perceived barriers were: lack of professional support on discharge from hospital and follow-up, transport issues to structured classes/interventions, lack of control and negative affect. Stroke survivors perceive several different barriers and facilitators to physical activity. Stroke services need to address barriers to physical activity and to build on facilitators to promote physical activity after stroke. Physical activity post stroke can improve physical fitness and function, yet physical activity remains low among stroke survivors. Understanding stroke survivors' perceived barriers and facilitators to physical activity is essential to develop targeted interventions to increase physical activity. Beliefs about capabilities, environmental

  17. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    Science.gov (United States)

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. An Analysis of Instructional Facilitators' Relationships with Teachers and Principals

    Science.gov (United States)

    Range, Bret G.; Pijanowski, John C.; Duncan, Heather; Scherz, Susan; Hvidston, David

    2014-01-01

    This study examines the perspectives of Wyoming instructional facilitators, concerning three coaching constructs--namely, their instructional leadership roles, teachers' instructional practices, and the support that they receive from principals and teachers. Findings suggest that instructional facilitators were positive about their instructional…

  19. Quantitative analysis of the ATV data base, Stage 2

    International Nuclear Information System (INIS)

    Stenquist, C.; Kjellbert, N.A.

    1981-01-01

    A supplementary study of the Swedish ATV data base was carried out. The study was limited to an analysis of the quantitative coverage of component failures from 1979 through 1980. The results indicate that the coverage of component failures is about 75-80 per cent related to the failure reports and work order sheets at the reactor sites together with SKI's ''Safety Related Occurrences''. In general there has been an improvement compared to previous years. (Auth.)

  20. Quantitative analysis of culture using millions of digitized books

    OpenAIRE

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva P.; Veres, Adrian; Gray, Matthew K.; Pickett, Joseph P.; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A.; Aiden, Erez Lieberman

    2010-01-01

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of ‘culturomics’, focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pu...

  1. Quantitative Analysis of Culture Using Millions of Digitized Books

    OpenAIRE

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva Presser; Veres, Adrian; Gray, Matthew K.; Google Books Team; Pickett, Joseph; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A.; Aiden, Erez Lieberman

    2011-01-01

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of ‘culturomics,’ focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pu...

  2. Quantitative comparison of performance analysis techniques for modular and generic network-on-chip

    Directory of Open Access Journals (Sweden)

    M. C. Neuenhahn

    2009-05-01

    Full Text Available NoC-specific parameters feature a huge impact on performance and implementation costs of NoC. Hence, performance and cost evaluation of these parameter-dependent NoC is crucial in different design-stages but the requirements on performance analysis differ from stage to stage. In an early design-stage an analysis technique featuring reduced complexity and limited accuracy can be applied, whereas in subsequent design-stages more accurate techniques are required.

    In this work several performance analysis techniques at different levels of abstraction are presented and quantitatively compared. These techniques include a static performance analysis using timing-models, a Colored Petri Net-based approach, VHDL- and SystemC-based simulators and an FPGA-based emulator. Conducting NoC-experiments with NoC-sizes from 9 to 36 functional units and various traffic patterns, characteristics of these experiments concerning accuracy, complexity and effort are derived.

    The performance analysis techniques discussed here are quantitatively evaluated and finally assigned to the appropriate design-stages in an automated NoC-design-flow.

  3. Attenuated total internal reflection Fourier transform infrared spectroscopy: a quantitative approach for kidney stone analysis.

    Science.gov (United States)

    Gulley-Stahl, Heather J; Haas, Jennifer A; Schmidt, Katherine A; Evan, Andrew P; Sommer, André J

    2009-07-01

    The impact of kidney stone disease is significant worldwide, yet methods for quantifying stone components remain limited. A new approach requiring minimal sample preparation for the quantitative analysis of kidney stone components has been investigated utilizing attenuated total internal reflection Fourier transform infrared spectroscopy (ATR-FT-IR). Calcium oxalate monohydrate (COM) and hydroxylapatite (HAP), two of the most common constituents of urinary stones, were used for quantitative analysis. Calibration curves were constructed using integrated band intensities of four infrared absorptions versus concentration (weight %). The correlation coefficients of the calibration curves range from 0.997 to 0.93. The limits of detection range from 0.07 +/- 0.02% COM/HAP where COM is the analyte and HAP is the matrix, to 0.26 +/- 0.07% HAP/COM where HAP is the analyte and COM is the matrix. This study shows that linear calibration curves can be generated for the quantitative analysis of stone mixtures provided the system is well understood especially with respect to particle size.

  4. Developments in Dynamic Analysis for quantitative PIXE true elemental imaging

    International Nuclear Information System (INIS)

    Ryan, C.G.

    2001-01-01

    Dynamic Analysis (DA) is a method for projecting quantitative major and trace element images from PIXE event data-streams (off-line or on-line) obtained using the Nuclear Microprobe. The method separates full elemental spectral signatures to produce images that strongly reject artifacts due to overlapping elements, detector effects (such as escape peaks and tailing) and background. The images are also quantitative, stored in ppm-charge units, enabling images to be directly interrogated for the concentrations of all elements in areas of the images. Recent advances in the method include the correction for changing X-ray yields due to varying sample compositions across the image area and the construction of statistical variance images. The resulting accuracy of major element concentrations extracted directly from these images is better than 3% relative as determined from comparisons with electron microprobe point analysis. These results are complemented by error estimates derived from the variance images together with detection limits. This paper provides an update of research on these issues, introduces new software designed to make DA more accessible, and illustrates the application of the method to selected geological problems.

  5. Analytical applications of a recycled flow nuclear magnetic resonance system: quantitative analysis of slowly relaxing nuclei

    International Nuclear Information System (INIS)

    Laude, D.A. Jr.; Lee, R.W.K.; Wilkins, C.L.

    1985-01-01

    The utility of a recycled flow system for the efficient quantitative analysis of NMR spectra is demonstrated. Requisite conditions are first established for the quantitative flow experiment and then applied to a variety of compounds. An application of the technique to determination of the average polymer chain length for a silicone polymer by quantitative flow 29 Si NMR is also presented. 10 references, 4 figures, 3 tables

  6. Facilitation as a teaching strategy : experiences of facilitators

    Directory of Open Access Journals (Sweden)

    E Lekalakala-Mokgele

    2006-09-01

    Full Text Available Changes in nursing education involve the move from traditional teaching approaches that are teacher-centred to facilitation, a student centred approach. The studentcentred approach is based on a philosophy of teaching and learning that puts the learner on centre-stage. The aim of this study was to identify the challenges of facilitators of learning using facilitation as a teaching method and recommend strategies for their (facilitators development and support. A qualitative, explorative and contextual design was used. Four (4 universities in South Africa which utilize facilitation as a teaching/ learning process were identified and the facilitators were selected to be the sample of the study. The main question posed during in-depth group interviews was: How do you experience facilitation as a teaching/learning method?. Facilitators indicated different experiences and emotions when they first had to facilitate learning. All of them indicated that it was difficult to facilitate at the beginning as they were trained to lecture and that no format for facilitation was available. They experienced frustrations and anxieties as a result. The lack of knowledge of facilitation instilled fear in them. However they indicated that facilitation had many benefits for them and for the students. Amongst the ones mentioned were personal and professional growth. Challenges mentioned were the fear that they waste time and that they do not cover the content. It is therefore important that facilitation be included in the training of nurse educators.

  7. Application of harmonic analysis in quantitative heart scintigraphy

    International Nuclear Information System (INIS)

    Fischer, P.; Knopp, R.; Breuel, H.P.

    1979-01-01

    Quantitative scintigraphy of the heart after equilibrium distribution of a radioactive tracer permits the measurement of time activity curves in the left ventricle during a representative heart cycle with great statistical accuracy. By application of Fourier's analysis, criteria are to be attained in addition for evaluation of the volume curve as a whole. Thus the entire information contained in the volume curve is completely described in a Fourier spectrum. Resynthesis after Fourier transformation seems to be an ideal method of smoothing because of its convergence in the minimum quadratic error for the type of function concerned. (orig./MG) [de

  8. Quantitative x-ray fluorescent analysis using fundamental parameters

    International Nuclear Information System (INIS)

    Sparks, C.J. Jr.

    1976-01-01

    A monochromatic source of x-rays for sample excitation permits the use of pure elemental standards and relatively simple calculations to convert the measured fluorescent intensities to an absolute basis of weight per unit weight of sample. Only the mass absorption coefficients of the sample for the exciting and the fluorescent radiation need be determined. Besides the direct measurement of these absorption coefficients in the sample, other techniques are considered which require fewer sample manipulations and measurements. These fundamental parameters methods permit quantitative analysis without recourse to the time-consuming process of preparing nearly identical standards

  9. The facilitators and barriers to nurses' participation in continuing education programs: a mixed method explanatory sequential study.

    Science.gov (United States)

    Shahhosseini, Zohreh; Hamzehgardeshi, Zeinab

    2014-11-30

    Since several factors affect nurses' participation in Continuing Education, and that nurses' Continuing Education affects patients' and community health status, it is essential to know facilitators and barriers of participation in Continuing Education programs and plan accordingly. This mixed approach study aimed to investigate the facilitators and barriers of nurses' participation, to explore nurses' perception of the most common facilitators and barriers. An explanatory sequential mixed methods design with follow up explanations variant were used, and it involved collecting quantitative data (361 nurses) first and then explaining the quantitative results with in-depth interviews during a qualitative study. The results showed that the mean score of facilitators to nurses' participation in Continuing Education was significantly higher than the mean score of barriers (61.99 ± 10.85 versus 51.17 ± 12.83; pEducation was related to "Update my knowledge". By reviewing the handwritings in qualitative phase, two main levels of updating information and professional skills were extracted as the most common facilitators and lack of support as the most common barrier to nurses' participation in continuing education program. According to important role Continuing Education on professional skills, nurse managers should facilitate the nurse' participation in the Continues Education.

  10. Quantitative analysis of thorium-containing materials using an Industrial XRF analyzer

    International Nuclear Information System (INIS)

    Hasikova, J.; Titov, V.; Sokolov, A.

    2014-01-01

    Thorium (Th) as nuclear fuel is clean and safe and offers significant advantages over uranium. The technology for several types of thorium reactors is proven but still must be developed on a commercial scale. In the case of commercialization of thorium nuclear reactor thorium raw materials will be on demand. With this, mining and processing companies producing Th and rare earth elements will require prompt and reliable methods and instrumentation for Th quantitative on-line analysis. Potential applicability of X-ray fluorescence conveyor analyzer CON-X series is discussed for Th quantitative or semi-quantitative on-line measurement in several types of Th-bearing materials. Laboratory study of several minerals (zircon sands and limestone as unconventional Th resources; monazite concentrate as Th associated resources and uranium ore residues after extraction as a waste product) was performed and analyzer was tested for on-line quantitative measurements of Th contents along with other major and minor components. Th concentration range in zircon sand is 50-350 ppm; its detection limit at this level is estimated at 25- 50 ppm in 5 minute measurements depending on the type of material. On-site test of the CON-X analyzer for continuous analysis of thorium traces along with other elements in zircon sand showed that accuracy of Th measurements is within 20% relative. When Th content is higher than 1% as in the concentrate of monazite ore (5-8% ThO_2) accuracy of Th determination is within 1% relative. Although preliminary on-site test is recommended in order to address system feasibility at a large scale, provided results show that industrial conveyor XRF analyzer CON-X series can be effectively used for analytical control of mining and processing streams of Th-bearing materials. (author)

  11. Some selected quantitative methods of thermal image analysis in Matlab.

    Science.gov (United States)

    Koprowski, Robert

    2016-05-01

    The paper presents a new algorithm based on some selected automatic quantitative methods for analysing thermal images. It shows the practical implementation of these image analysis methods in Matlab. It enables to perform fully automated and reproducible measurements of selected parameters in thermal images. The paper also shows two examples of the use of the proposed image analysis methods for the area of ​​the skin of a human foot and face. The full source code of the developed application is also provided as an attachment. The main window of the program during dynamic analysis of the foot thermal image. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Quantitative CT analysis of small pulmonary vessels in lymphangioleiomyomatosis

    International Nuclear Information System (INIS)

    Ando, Katsutoshi; Tobino, Kazunori; Kurihara, Masatoshi; Kataoka, Hideyuki; Doi, Tokuhide; Hoshika, Yoshito; Takahashi, Kazuhisa; Seyama, Kuniaki

    2012-01-01

    Backgrounds: Lymphangioleiomyomatosis (LAM) is a destructive lung disease that share clinical, physiologic, and radiologic features with chronic obstructive pulmonary disease (COPD). This study aims to identify those features that are unique to LAM by using quantitative CT analysis. Methods: We measured total cross-sectional areas of small pulmonary vessels (CSA) less than 5 mm 2 and 5–10 mm 2 and calculated percentages of those lung areas (%CSA), respectively, in 50 LAM and 42 COPD patients. The extent of cystic destruction (LAA%) and mean parenchymal CT value were also calculated and correlated with pulmonary function. Results: The diffusing capacity for carbon monoxide/alveolar volume (DL CO /VA %predicted) was similar for both groups (LAM, 44.4 ± 19.8% vs. COPD, 45.7 ± 16.0%, p = 0.763), but less tissue damage occurred in LAM than COPD (LAA% 21.7 ± 16.3% vs. 29.3 ± 17.0; p CO /VA %predicted, %CSA and mean parenchymal CT value were still greater for LAM than COPD (p < 0.05). Conclusions: Quantitative CT analysis revealing a correlation between cystic destruction and CSA in COPD but not LAM indicates that this approach successfully reflects different mechanisms governing the two pathologic courses. Such determinations of small pulmonary vessel density may serve to differentiate LAM from COPD even in patients with severe lung destruction.

  13. Large-scale quantitative analysis of painting arts.

    Science.gov (United States)

    Kim, Daniel; Son, Seung-Woo; Jeong, Hawoong

    2014-12-11

    Scientists have made efforts to understand the beauty of painting art in their own languages. As digital image acquisition of painting arts has made rapid progress, researchers have come to a point where it is possible to perform statistical analysis of a large-scale database of artistic paints to make a bridge between art and science. Using digital image processing techniques, we investigate three quantitative measures of images - the usage of individual colors, the variety of colors, and the roughness of the brightness. We found a difference in color usage between classical paintings and photographs, and a significantly low color variety of the medieval period. Interestingly, moreover, the increment of roughness exponent as painting techniques such as chiaroscuro and sfumato have advanced is consistent with historical circumstances.

  14. Operation Iraqi Freedom 04 - 06: Opportunities to Apply Quantitative Methods to Intelligence Analysis

    National Research Council Canada - National Science Library

    Hansen, Eric C

    2005-01-01

    The purpose of this presentation is to illustrate the need for a quantitative analytical capability within organizations and staffs that provide intelligence analysis to Army, Joint, and Coalition Force headquarters...

  15. Toward best practices in data processing and analysis for intact biotherapeutics by MS in quantitative bioanalysis.

    Science.gov (United States)

    Kellie, John F; Kehler, Jonathan R; Karlinsey, Molly Z; Summerfield, Scott G

    2017-12-01

    Typically, quantitation of biotherapeutics from biological matrices by LC-MS is based on a surrogate peptide approach to determine molecule concentration. Recent efforts have focused on quantitation of the intact protein molecules or larger mass subunits of monoclonal antibodies. To date, there has been limited guidance for large or intact protein mass quantitation for quantitative bioanalysis. Intact- and subunit-level analyses of biotherapeutics from biological matrices are performed at 12-25 kDa mass range with quantitation data presented. Linearity, bias and other metrics are presented along with recommendations made on the viability of existing quantitation approaches. This communication is intended to start a discussion around intact protein data analysis and processing, recognizing that other published contributions will be required.

  16. Ratio of slopes method for quantitative analysis in ceramic bodies

    International Nuclear Information System (INIS)

    Zainal Arifin Ahmad; Ahmad Fauzi Mohd Noor; Radzali Othman; Messer, P.F.

    1996-01-01

    A quantitative x-ray diffraction analysis technique developed at University of Sheffield was adopted, rather than the previously widely used internal standard method, to determine the amount of the phases present in a reformulated whiteware porcelain and a BaTiO sub 3 electrochemical material. This method, although still employs an internal standard, was found to be very easy and accurate. The required weight fraction of a phase in the mixture to be analysed is determined from the ratio of slopes of two linear plots, designated as the analysis and reference lines, passing through their origins using the least squares method

  17. Quantitative descriptive analysis and principal component analysis for sensory characterization of Indian milk product cham-cham.

    Science.gov (United States)

    Puri, Ritika; Khamrui, Kaushik; Khetra, Yogesh; Malhotra, Ravinder; Devraja, H C

    2016-02-01

    Promising development and expansion in the market of cham-cham, a traditional Indian dairy product is expected in the coming future with the organized production of this milk product by some large dairies. The objective of this study was to document the extent of variation in sensory properties of market samples of cham-cham collected from four different locations known for their excellence in cham-cham production and to find out the attributes that govern much of variation in sensory scores of this product using quantitative descriptive analysis (QDA) and principal component analysis (PCA). QDA revealed significant (p sensory attributes of cham-cham among the market samples. PCA identified four significant principal components that accounted for 72.4 % of the variation in the sensory data. Factor scores of each of the four principal components which primarily correspond to sweetness/shape/dryness of interior, surface appearance/surface dryness, rancid and firmness attributes specify the location of each market sample along each of the axes in 3-D graphs. These findings demonstrate the utility of quantitative descriptive analysis for identifying and measuring attributes of cham-cham that contribute most to its sensory acceptability.

  18. Facilitators and barriers to external cephalic version for breech presentation at term among health care providers in the Netherlands: a quantitative analysis.

    Science.gov (United States)

    Rosman, Ageeth N; Vlemmix, Floortje; Beuckens, Antje; Rijnders, Marlies E; Opmeer, Brent C; Mol, Ben Willem J; Kok, Marjolein; Fleuren, Margot A H

    2014-03-01

    guidelines recommend that external cephalic version (ECV) should be offered to all women with a fetus in breech presentation at term. However, only 50-60% of the women receive an ECV attempt. We explored the determinants (barriers and facilitators) affecting the uptake of the guidelines among gynaecologists and midwives in the Netherlands. national online survey. the Netherlands. gynaecologists and midwives. in the online survey, we identified the determinants that positively or negatively influenced the professionals׳ adherence to three key recommendations in the guidelines: (a) counselling, (b) advising for ECV, (c) arranging an ECV. Determinants were identified in a previously performed qualitative study and were categorised into five underlying constructs; attitude towards ECV, professional obligation, outcome expectations, self-efficacy and preconditions for successful ECV. We performed a multivariate analysis to assess the importance of the different constructs for adherence to the guideline. 364 professionals responded to the survey. Adherence varied: 84% counselled, 73% advised, and 82% arranged an ECV for (almost) all their clients. Although 90% of respondents considered ECV to be an effective treatment for preventing caesarean childbirths, only 30% agreed that 'every client should undergo ECV'. Self-efficacy (perceived skills) was the most important determinant influencing adherence. self-efficacy appears to be the most significant determinant for counselling, advising and arranging an ECV. to improve adherence to the guidelines on ECV we must improve self-efficacy. Copyright © 2014. Published by Elsevier Ltd.

  19. Quantitative analysis of Esophageal Transit of Radionuclide in Patients with Dermatomyositis-Polymyositis

    International Nuclear Information System (INIS)

    Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Lee, Myung Hae

    1989-01-01

    Esophageal transit of radionuclide was quantitatively analyzed in 29 patients with dermatomyositis-polymyositis Fourteen patients (48.3%) showed retention of tracer in oropharynx. The mean value of percent retention of oropharynx was 15.5+16.6%. Esophageal dysfunction was found in 19 patients (65.5%). Among them 4 showed mild, 12 showed moderate and 3 showed severe esophageal dysfunction. Dysphagia was found in 11 patients (37.9%), which was closely related to percent retention of oropharynx. Quantitative analysis of esophageal transit of radionuclide seemed to be a useful technique for evaluation of dysphagia in patients with dermatomyositis-polymyositis.

  20. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    Science.gov (United States)

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Quantitative imaging biomarkers: the application of advanced image processing and analysis to clinical and preclinical decision making.

    Science.gov (United States)

    Prescott, Jeffrey William

    2013-02-01

    The importance of medical imaging for clinical decision making has been steadily increasing over the last four decades. Recently, there has also been an emphasis on medical imaging for preclinical decision making, i.e., for use in pharamaceutical and medical device development. There is also a drive towards quantification of imaging findings by using quantitative imaging biomarkers, which can improve sensitivity, specificity, accuracy and reproducibility of imaged characteristics used for diagnostic and therapeutic decisions. An important component of the discovery, characterization, validation and application of quantitative imaging biomarkers is the extraction of information and meaning from images through image processing and subsequent analysis. However, many advanced image processing and analysis methods are not applied directly to questions of clinical interest, i.e., for diagnostic and therapeutic decision making, which is a consideration that should be closely linked to the development of such algorithms. This article is meant to address these concerns. First, quantitative imaging biomarkers are introduced by providing definitions and concepts. Then, potential applications of advanced image processing and analysis to areas of quantitative imaging biomarker research are described; specifically, research into osteoarthritis (OA), Alzheimer's disease (AD) and cancer is presented. Then, challenges in quantitative imaging biomarker research are discussed. Finally, a conceptual framework for integrating clinical and preclinical considerations into the development of quantitative imaging biomarkers and their computer-assisted methods of extraction is presented.

  2. Quantitative analysis of microtubule orientation in interdigitated leaf pavement cells.

    Science.gov (United States)

    Akita, Kae; Higaki, Takumi; Kutsuna, Natsumaro; Hasezawa, Seiichiro

    2015-01-01

    Leaf pavement cells are shaped like a jigsaw puzzle in most dicotyledon species. Molecular genetic studies have identified several genes required for pavement cells morphogenesis and proposed that microtubules play crucial roles in the interdigitation of pavement cells. In this study, we performed quantitative analysis of cortical microtubule orientation in leaf pavement cells in Arabidopsis thaliana. We captured confocal images of cortical microtubules in cotyledon leaf epidermis expressing GFP-tubulinβ and quantitatively evaluated the microtubule orientations relative to the pavement cell growth axis using original image processing techniques. Our results showed that microtubules kept parallel orientations to the growth axis during pavement cell growth. In addition, we showed that immersion treatment of seed cotyledons in solutions containing tubulin polymerization and depolymerization inhibitors decreased pavement cell complexity. Treatment with oryzalin and colchicine inhibited the symmetric division of guard mother cells.

  3. An iterative approach to case study analysis: insights from qualitative analysis of quantitative inconsistencies

    Directory of Open Access Journals (Sweden)

    Allain J Barnett

    2016-09-01

    Full Text Available Large-N comparative studies have helped common pool resource scholars gain general insights into the factors that influence collective action and governance outcomes. However, these studies are often limited by missing data, and suffer from the methodological limitation that important information is lost when we reduce textual information to quantitative data. This study was motivated by nine case studies that appeared to be inconsistent with the expectation that the presence of Ostrom’s Design Principles increases the likelihood of successful common pool resource governance. These cases highlight the limitations of coding and analysing Large-N case studies. We examine two issues: 1 the challenge of missing data and 2 potential approaches that rely on context (which is often lost in the coding process to address inconsistencies between empirical observations theoretical predictions.  For the latter, we conduct a post-hoc qualitative analysis of a large-N comparative study to explore 2 types of inconsistencies: 1 cases where evidence for nearly all design principles was found, but available evidence led to the assessment that the CPR system was unsuccessful and 2 cases where the CPR system was deemed successful despite finding limited or no evidence for design principles.  We describe inherent challenges to large-N comparative analysis to coding complex and dynamically changing common pool resource systems for the presence or absence of design principles and the determination of “success”.  Finally, we illustrate how, in some cases, our qualitative analysis revealed that the identity of absent design principles explained inconsistencies hence de-facto reconciling such apparent inconsistencies with theoretical predictions.  This analysis demonstrates the value of combining quantitative and qualitative analysis, and using mixed-methods approaches iteratively to build comprehensive methodological and theoretical approaches to understanding

  4. Quantitative chromatography in the analysis of labelled compounds 1. Quantitative paper chromotography of amino acids by A spot comparison technique

    International Nuclear Information System (INIS)

    Barakat, M.F.; Farag, A.N.; El-Gharbawy, A.A.

    1974-01-01

    For the determination of the specific activity of labelled compounds separated by paper sheet chromatography, it was found essential to perfect the quantitative aspect of the paper chromatographic technique. Actually, so far paper chromatography has been used as a separation tool mainly and its use in quantification of the separated materials is by far less studied. In the present work, the quantitative analysis of amino acids by paper sheet chromatography has been carried out by methods, depending on the use of the relative spot area values for correcting the experimental data obtained. The results obtained were good and reproducible. The main advantage of the proposed technique is its extreme simplicity. No complicated equipment of procedures are necessary

  5. Quantitative charge-tags for sterol and oxysterol analysis.

    Science.gov (United States)

    Crick, Peter J; William Bentley, T; Abdel-Khalik, Jonas; Matthews, Ian; Clayton, Peter T; Morris, Andrew A; Bigger, Brian W; Zerbinati, Chiara; Tritapepe, Luigi; Iuliano, Luigi; Wang, Yuqin; Griffiths, William J

    2015-02-01

    Global sterol analysis is challenging owing to the extreme diversity of sterol natural products, the tendency of cholesterol to dominate in abundance over all other sterols, and the structural lack of a strong chromophore or readily ionized functional group. We developed a method to overcome these challenges by using different isotope-labeled versions of the Girard P reagent (GP) as quantitative charge-tags for the LC-MS analysis of sterols including oxysterols. Sterols/oxysterols in plasma were extracted in ethanol containing deuterated internal standards, separated by C18 solid-phase extraction, and derivatized with GP, with or without prior oxidation of 3β-hydroxy to 3-oxo groups. By use of different isotope-labeled GPs, it was possible to analyze in a single LC-MS analysis both sterols/oxysterols that naturally possess a 3-oxo group and those with a 3β-hydroxy group. Intra- and interassay CVs were sterols/oxysterols in a single analytical run and can be used to identify inborn errors of cholesterol synthesis and metabolism. © 2014 American Association for Clinical Chemistry.

  6. Quantitative CT analysis of small pulmonary vessels in lymphangioleiomyomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Katsutoshi, E-mail: kando@juntendo.ac.jp [Department of Internal Medicine, Division of Respiratory Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); Tobino, Kazunori [Department of Respiratory Medicine, Iizuka Hospital, 3-83 Yoshio-Machi, Iizuka-City, Fukuoka 820-8505 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); Kurihara, Masatoshi; Kataoka, Hideyuki [Pneumothorax Center, Nissan Tamagawa Hospital, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); Doi, Tokuhide [Fukuoka Clinic, 7-18-11 Umeda, Adachi-Ku, Tokyo 123-0851 (Japan); Hoshika, Yoshito [Department of Internal Medicine, Division of Respiratory Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); Takahashi, Kazuhisa [Department of Internal Medicine, Division of Respiratory Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Seyama, Kuniaki [Department of Internal Medicine, Division of Respiratory Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan)

    2012-12-15

    Backgrounds: Lymphangioleiomyomatosis (LAM) is a destructive lung disease that share clinical, physiologic, and radiologic features with chronic obstructive pulmonary disease (COPD). This study aims to identify those features that are unique to LAM by using quantitative CT analysis. Methods: We measured total cross-sectional areas of small pulmonary vessels (CSA) less than 5 mm{sup 2} and 5–10 mm{sup 2} and calculated percentages of those lung areas (%CSA), respectively, in 50 LAM and 42 COPD patients. The extent of cystic destruction (LAA%) and mean parenchymal CT value were also calculated and correlated with pulmonary function. Results: The diffusing capacity for carbon monoxide/alveolar volume (DL{sub CO}/VA %predicted) was similar for both groups (LAM, 44.4 ± 19.8% vs. COPD, 45.7 ± 16.0%, p = 0.763), but less tissue damage occurred in LAM than COPD (LAA% 21.7 ± 16.3% vs. 29.3 ± 17.0; p < 0.05). Pulmonary function correlated negatively with LAA% (p < 0.001) in both groups, yet the correlation with %CSA was significant only in COPD (p < 0.001). When the same analysis was conducted in two groups with equal levels of LAA% and DL{sub CO}/VA %predicted, %CSA and mean parenchymal CT value were still greater for LAM than COPD (p < 0.05). Conclusions: Quantitative CT analysis revealing a correlation between cystic destruction and CSA in COPD but not LAM indicates that this approach successfully reflects different mechanisms governing the two pathologic courses. Such determinations of small pulmonary vessel density may serve to differentiate LAM from COPD even in patients with severe lung destruction.

  7. Physical aspects of quantitative particles analysis by X-ray fluorescence and electron microprobe techniques

    International Nuclear Information System (INIS)

    Markowicz, A.

    1986-01-01

    The aim of this work is to present both physical fundamentals and recent advances in quantitative particles analysis by X-ray fluorescence (XRF) and electron microprobe (EPXMA) techniques. A method of correction for the particle-size effect in XRF analysis is described and theoretically evaluated. New atomic number- and absorption correction procedures in EPXMA of individual particles are proposed. The applicability of these two correction methods is evaluated for a wide range of elemental composition, X-ray energy and sample thickness. Also, a theoretical model for composition and thickness dependence of Bremsstrahlung background generated in multielement bulk specimens as well as thin films and particles are presented and experimantally evaluated. Finally, the limitations and further possible improvements in quantitative particles analysis by XFR and EPXMA are discussed. 109 refs. (author)

  8. Characterising Ageing in the Human Brainstem Using Quantitative Multimodal MRI Analysis

    Directory of Open Access Journals (Sweden)

    Christian eLambert

    2013-08-01

    Full Text Available Ageing is ubiquitous to the human condition. The MRI correlates of healthy ageing have been extensively investigated using a range of modalities, including volumetric MRI, quantitative MRI and DTI. Despite this, the reported brainstem related changes remain sparse. This is, in part, due to the technical and methodological limitations in quantitatively assessing and statistically analysing this region. By utilising a new method of brainstem segmentation, a large cohort of 100 healthy adults were assessed in this study for the effects of ageing within the human brainstem in vivo. Using quantitative MRI (qMRI, tensor based morphometry (TBM and voxel based quantification (VBQ, the volumetric and quantitative changes across healthy adults between 19-75 years were characterised. In addition to the increased R2* in substantia nigra corresponding to increasing iron deposition with age, several novel findings were reported in the current study. These include selective volumetric loss of the brachium conjunctivum, with a corresponding decrease in magnetisation transfer (MT and increase in proton density (PD, accounting for the previously described midbrain shrinkage. Additionally, we found increases in R1 and PD in several pontine and medullary structures. We consider these changes in the context of well-characterised, functional age-related changes, and propose potential biophysical mechanisms. This study provides detailed quantitative analysis of the internal architecture of the brainstem and provides a baseline for further studies of neurodegenerative diseases that are characterised by early, pre-clinical involvement of the brainstem, such as Parkinson’s and Alzheimer’s diseases.

  9. Recent advances on multidimensional liquid chromatography–mass spectrometry for proteomics: From qualitative to quantitative analysis—A review

    International Nuclear Information System (INIS)

    Wu Qi; Yuan Huiming; Zhang Lihua; Zhang Yukui

    2012-01-01

    Highlights: ► We discuss progress of MDLC–MS systems in qualitative and quantitative proteomics. ► Both “Top-down” and “bottom-up” strategies are discussed in detail. ► On-line integrations of stable isotope labeling process are highlighted. ► This review gives insights into further directions for higher level integration. - Abstract: With the acceleration of proteome research, increasing attention has been paid to multidimensional liquid chromatography–mass spectrometry (MDLC–MS) due to its high peak capacity and separation efficiency. Recently, many efforts have been put to improve MDLC-based strategies including “top-down” and “bottom-up” to enable highly sensitive qualitative and quantitative analysis of proteins, as well as accelerate the whole analytical procedure. Integrated platforms with combination of sample pretreatment, multidimensional separations and identification were also developed to achieve high throughput and sensitive detection of proteomes, facilitating highly accurate and reproducible quantification. This review summarized the recent advances of such techniques and their applications in qualitative and quantitative analysis of proteomes.

  10. Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe

    CERN Document Server

    Vekemans, B; Somogyi, A; Drakopoulos, M; Kempenaers, L; Simionovici, A; Adams, F

    2003-01-01

    The new ID18F end-station at the European synchrotron radiation facility (ESRF) in Grenoble (France) is dedicated to sensitive and accurate quantitative micro-X-ray fluorescence (XRF) analysis at the ppm level with accuracy better than 10% for elements with atomic numbers above 18. For accurate quantitative analysis, given a high level of instrumental stability, major steps are the extraction and conversion of experimental X-ray line intensities into elemental concentrations. For this purpose a two-step quantification approach was adopted. In the first step, the collected XRF spectra are deconvoluted on the basis of a non-linear least-squares fitting algorithm (AXIL). The extracted characteristic line intensities are then used as input for a detailed Monte Carlo (MC) simulation code dedicated to XRF spectroscopy taking into account specific experimental conditions (excitation/detection) as well as sample characteristics (absorption and enhancement effects, sample topology, heterogeneity etc.). The iterative u...

  11. The Study on the Quantitative Analysis in LPG Tank's Fire and Explosion

    Energy Technology Data Exchange (ETDEWEB)

    Bae, S.J.; Kim, B.J. [Department of chemical Engineering, Soongsil University, Seoul (Korea)

    1999-04-01

    Chemical plant's fire and explosion does not only damage to the chemical plants themselves but also damage to people in or near of the accident spot and the neighborhood of chemical plant. For that reason, Chemical process safety management has become important. One of safety management methods is called 'the quantitative analysis', which is used to reduce and prevent the accident. The results of the quantitative analysis could be used to arrange the equipments, evaluate the minimum safety distance, prepare the safety equipments. In this study we make the computer program to make easy to do quantitative analysis of the accident. The output of the computer program is the magnitude of fire(pool fire and fireball) and explosion (UVCE and BLEVE) effects. We used the thermal radiation as a measure of fire magnitude and used the overpressure as a measure of explosion magnitude. In case of BLEVE, the fly distance of fragment can be evaluated. Also probit analysis was done in every case. As the case study, Buchun LPG explosion accident in Korea was analysed by the program developed. The simulation results showed that the permissible distance was 800m and probit analysis showed that 1st degree burn, 2nd degree burn, and death distances are 450, 280, 260m, respectively. the simulation results showed the good agreement with the result from SAFER PROGRAM made by DuPont. 13 refs., 4 figs., 2 tabs.

  12. Comparison of different surface quantitative analysis methods. Application to corium

    International Nuclear Information System (INIS)

    Guilbaud, N.; Blin, D.; Perodeaud, Ph.; Dugne, O.; Gueneau, Ch.

    2000-01-01

    In case of a severe hypothetical accident in a pressurized water reactor, the reactor assembly melts partially or completely. The material formed, called corium, flows out and spreads at the bottom of the reactor. To limit and control the consequences of such an accident, the specifications of the O-U-Zr basic system must be known accurately. To achieve this goal, the corium mix was melted by electron bombardment at very high temperature (3000 K) followed by quenching of the ingot in the Isabel 1 evaporator. Metallographic analyses were then required to validate the thermodynamic databases set by the Thermo-Calc software. The study consists in defining an overall surface quantitative analysis method that is fast and reliable, in order to determine the overall corium composition. The analyzed ingot originated in a [U+Fe+Y+UO 2 +ZrO 2 ) mix, with a total mass of 2253.7 grams. Several successive heating with average power were performed before a very brief plateau at very high temperature, so that the ingot was formed progressively and without any evaporation liable to modify its initial composition. The central zone of the ingot was then analyzed by qualitative and quantitative global surface methods, to yield the volume composition of the analyzed zone. Corium sample analysis happens to be very complex because of the variety and number of elements present, and also because of the presence of oxygen in a heavy element like the uranium based matrix. Three different global quantitative surface analysis methods were used: global EDS analysis (Energy Dispersive Spectrometry), with SEM, global WDS analysis (Wavelength Dispersive Spectrometry) with EPMA, and coupling of image analysis with EDS or WDS point spectroscopic analyses. The difficulties encountered during the study arose from sample preparation (corium is very sensitive to oxidation), and the choice of acquisition parameters of the images and analyses. The corium sample studied consisted of two zones displaying

  13. Quantitative Motion Analysis of Tai Chi Chuan: The Upper Extremity Movement

    Directory of Open Access Journals (Sweden)

    Tsung-Jung Ho

    2018-01-01

    Full Text Available The quantitative and reproducible analysis of the standard body movement in Tai Chi Chuan (TCC was performed in this study. We aimed to provide a reference of the upper extremities for standardizing TCC practice. Microsoft Kinect was used to record the motion during the practice of TCC. The preparation form and eight essential forms of TCC performed by an instructor and 101 practitioners were analyzed in this study. The instructor completed an entire TCC practice cycle and performed the cycle 12 times. An entire cycle of TCC was performed by practitioners and images were recorded for statistics analysis. The performance of the instructor showed high similarity (Pearson correlation coefficient (r=0.71~0.84 to the first practice cycle. Among the 9 forms, lay form had the highest similarity (rmean=0.90 and push form had the lowest similarity (rmean=0.52. For the practitioners, ward off form (rmean=0.51 and roll back form (rmean=0.45 had the highest similarity with moderate correlation. We used Microsoft Kinect to record the spatial coordinates of the upper extremity joints during the practice of TCC and the data to perform quantitative and qualitative analysis of the joint positions and elbow joint angle.

  14. Quantitative Analysis in Nuclear Medicine Imaging

    CERN Document Server

    2006-01-01

    This book provides a review of image analysis techniques as they are applied in the field of diagnostic and therapeutic nuclear medicine. Driven in part by the remarkable increase in computing power and its ready and inexpensive availability, this is a relatively new yet rapidly expanding field. Likewise, although the use of radionuclides for diagnosis and therapy has origins dating back almost to the discovery of natural radioactivity itself, radionuclide therapy and, in particular, targeted radionuclide therapy has only recently emerged as a promising approach for therapy of cancer and, to a lesser extent, other diseases. As effort has, therefore, been made to place the reviews provided in this book in a broader context. The effort to do this is reflected by the inclusion of introductory chapters that address basic principles of nuclear medicine imaging, followed by overview of issues that are closely related to quantitative nuclear imaging and its potential role in diagnostic and therapeutic applications. ...

  15. A Systematic Approach for Quantitative Analysis of Multidisciplinary Design Optimization Framework

    Science.gov (United States)

    Kim, Sangho; Park, Jungkeun; Lee, Jeong-Oog; Lee, Jae-Woo

    An efficient Multidisciplinary Design and Optimization (MDO) framework for an aerospace engineering system should use and integrate distributed resources such as various analysis codes, optimization codes, Computer Aided Design (CAD) tools, Data Base Management Systems (DBMS), etc. in a heterogeneous environment, and need to provide user-friendly graphical user interfaces. In this paper, we propose a systematic approach for determining a reference MDO framework and for evaluating MDO frameworks. The proposed approach incorporates two well-known methods, Analytic Hierarchy Process (AHP) and Quality Function Deployment (QFD), in order to provide a quantitative analysis of the qualitative criteria of MDO frameworks. Identification and hierarchy of the framework requirements and the corresponding solutions for the reference MDO frameworks, the general one and the aircraft oriented one were carefully investigated. The reference frameworks were also quantitatively identified using AHP and QFD. An assessment of three in-house frameworks was then performed. The results produced clear and useful guidelines for improvement of the in-house MDO frameworks and showed the feasibility of the proposed approach for evaluating an MDO framework without a human interference.

  16. A quantitative impact analysis of sensor failures on human operator's decision making in nuclear power plants

    International Nuclear Information System (INIS)

    Seong, Poong Hyun

    2004-01-01

    In emergency or accident situations in nuclear power plants, human operators take important roles in generating appropriate control signals to mitigate accident situation. In human reliability analysis (HRA) in the framework of probabilistic safety assessment (PSA), the failure probabilities of such appropriate actions are estimated and used for the safety analysis of nuclear power plants. Even though understanding the status of the plant is basically the process of information seeking and processing by human operators, it seems that conventional HRA methods such as THERP, HCR, and ASEP does not pay a lot of attention to the possibilities of providing wrong information to human operators. In this paper, a quantitative impact analysis of providing wrong information to human operators due to instrument faults or sensor failures is performed. The quantitative impact analysis is performed based on a quantitative situation assessment model. By comparing the situation in which there are sensor failures and the situation in which there are not sensor failures, the impact of sensor failures can be evaluated quantitatively. It is concluded that the impact of sensor failures are quite significant at the initial stages, but the impact is gradually reduced as human operators make more and more observations. Even though the impact analysis is highly dependent on the situation assessment model, it is expected that the conclusions made based on other situation assessment models with be consistent with the conclusion made in this paper. (author)

  17. A quantitative analysis of coupled oscillations using mobile accelerometer sensors

    International Nuclear Information System (INIS)

    Castro-Palacio, Juan Carlos; Velázquez-Abad, Luisberis; Giménez, Fernando; Monsoriu, Juan A

    2013-01-01

    In this paper, smartphone acceleration sensors were used to perform a quantitative analysis of mechanical coupled oscillations. Symmetric and asymmetric normal modes were studied separately in the first two experiments. In the third, a coupled oscillation was studied as a combination of the normal modes. Results indicate that acceleration sensors of smartphones, which are very familiar to students, represent valuable measurement instruments for introductory and first-year physics courses. (paper)

  18. A quantitative analysis of coupled oscillations using mobile accelerometer sensors

    Science.gov (United States)

    Castro-Palacio, Juan Carlos; Velázquez-Abad, Luisberis; Giménez, Fernando; Monsoriu, Juan A.

    2013-05-01

    In this paper, smartphone acceleration sensors were used to perform a quantitative analysis of mechanical coupled oscillations. Symmetric and asymmetric normal modes were studied separately in the first two experiments. In the third, a coupled oscillation was studied as a combination of the normal modes. Results indicate that acceleration sensors of smartphones, which are very familiar to students, represent valuable measurement instruments for introductory and first-year physics courses.

  19. The Quantitative Analysis of a team game performance made by men basketball teams at OG 2008

    OpenAIRE

    Kocián, Michal

    2009-01-01

    Title: The quantitative analysis of e team game performance made by men basketball teams at Olympis games 2008 Aims: Find reason successes and failures of teams in Olympis game play-off using quantitative (numerical) observation of selected game statistics. Method: The thesis was made on the basic a quantitative (numerical) observation of videorecordings using KVANTÝM. Results: Obtained selected statistic desribed the most essentials events for team winning or loss. Keywords: basketball, team...

  20. The cost of electricity distribution in Italy: a quantitative analysis

    International Nuclear Information System (INIS)

    Scarpa, C.

    1998-01-01

    This paper presents a quantitative analysis of the cost of medium and low tension electricity distribution in Italy. An econometric analysis of the cost function is proposed, on the basis of data on 147 zones of the dominant firm, ENEL. Data are available only for 1996, which has forced to carry out only a cross-section OLS analysis. The econometric estimate shows the existence of significant scale economies, that the current organisational structure does not exploit. On this basis is also possible to control to what extent exogenous cost drivers affect costs. The role of numerous exogenous factors considered seems however quite limited. The area of the distribution zone and an indicator of quality are the only elements that appear significant from an economic viewpoint [it

  1. Quantitative analysis of wet-heat inactivation in bovine spongiform encephalopathy

    International Nuclear Information System (INIS)

    Matsuura, Yuichi; Ishikawa, Yukiko; Bo, Xiao; Murayama, Yuichi; Yokoyama, Takashi; Somerville, Robert A.; Kitamoto, Tetsuyuki; Mohri, Shirou

    2013-01-01

    Highlights: ► We quantitatively analyzed wet-heat inactivation of the BSE agent. ► Infectivity of the BSE macerate did not survive 155 °C wet-heat treatment. ► Once the sample was dehydrated, infectivity was observed even at 170 °C. ► A quantitative PMCA assay was used to evaluate the degree of BSE inactivation. - Abstract: The bovine spongiform encephalopathy (BSE) agent is resistant to conventional microbial inactivation procedures and thus threatens the safety of cattle products and by-products. To obtain information necessary to assess BSE inactivation, we performed quantitative analysis of wet-heat inactivation of infectivity in BSE-infected cattle spinal cords. Using a highly sensitive bioassay, we found that infectivity in BSE cattle macerates fell with increase in temperatures from 133 °C to 150 °C and was not detected in the samples subjected to temperatures above 155 °C. In dry cattle tissues, infectivity was detected even at 170 °C. Thus, BSE infectivity reduces with increase in wet-heat temperatures but is less affected when tissues are dehydrated prior to the wet-heat treatment. The results of the quantitative protein misfolding cyclic amplification assay also demonstrated that the level of the protease-resistant prion protein fell below the bioassay detection limit by wet-heat at 155 °C and higher and could help assess BSE inactivation. Our results show that BSE infectivity is strongly resistant to wet-heat inactivation and that it is necessary to pay attention to BSE decontamination in recycled cattle by-products

  2. Quantitative analysis of wet-heat inactivation in bovine spongiform encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yuichi; Ishikawa, Yukiko; Bo, Xiao; Murayama, Yuichi; Yokoyama, Takashi [Prion Disease Research Center, National Institute of Animal Health, 3-1-5 Kannondai, Tsukuba, Ibaraki 305-0856 (Japan); Somerville, Robert A. [The Roslin Institute and Royal (Dick) School of Veterinary Studies, Roslin, Midlothian, EH25 9PS (United Kingdom); Kitamoto, Tetsuyuki [Division of CJD Science and Technology, Department of Prion Research, Center for Translational and Advanced Animal Research on Human Diseases, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575 (Japan); Mohri, Shirou, E-mail: shirou@affrc.go.jp [Prion Disease Research Center, National Institute of Animal Health, 3-1-5 Kannondai, Tsukuba, Ibaraki 305-0856 (Japan)

    2013-03-01

    Highlights: ► We quantitatively analyzed wet-heat inactivation of the BSE agent. ► Infectivity of the BSE macerate did not survive 155 °C wet-heat treatment. ► Once the sample was dehydrated, infectivity was observed even at 170 °C. ► A quantitative PMCA assay was used to evaluate the degree of BSE inactivation. - Abstract: The bovine spongiform encephalopathy (BSE) agent is resistant to conventional microbial inactivation procedures and thus threatens the safety of cattle products and by-products. To obtain information necessary to assess BSE inactivation, we performed quantitative analysis of wet-heat inactivation of infectivity in BSE-infected cattle spinal cords. Using a highly sensitive bioassay, we found that infectivity in BSE cattle macerates fell with increase in temperatures from 133 °C to 150 °C and was not detected in the samples subjected to temperatures above 155 °C. In dry cattle tissues, infectivity was detected even at 170 °C. Thus, BSE infectivity reduces with increase in wet-heat temperatures but is less affected when tissues are dehydrated prior to the wet-heat treatment. The results of the quantitative protein misfolding cyclic amplification assay also demonstrated that the level of the protease-resistant prion protein fell below the bioassay detection limit by wet-heat at 155 °C and higher and could help assess BSE inactivation. Our results show that BSE infectivity is strongly resistant to wet-heat inactivation and that it is necessary to pay attention to BSE decontamination in recycled cattle by-products.

  3. Quantitative analysis of iodine in thyroidin. I. Methods of ''dry'' and ''wet'' mineralization

    International Nuclear Information System (INIS)

    Listov, S.A.; Arzamastsev, A.P.

    1986-01-01

    The relative investigations on the quantitative determination of iodine in thyroidin using different modifications of the ''dry'' and ''wet'' mineralization show that in using these methods the difficulties due to the characteristic features of the object of investigation itself and the mineralization method as a whole must be taken into account. The studies show that the most applicable method for the analysis of thyroidin is the method of ''dry'' mineralization with potassium carbonate. A procedure is proposed for a quantitative determination of iodine in thyroidin

  4. Quantitative evaluation of fluctuation error in X-ray diffraction profiles with fractal analysis

    International Nuclear Information System (INIS)

    Kurose, Masashi; Hirose, Yukio; Sasaki, Toshihiko; Yoshioka, Yasuo.

    1995-01-01

    A method of the fractal analysis was applied to the diffraction profiles for its quantitative evaluation. The fractal dimension was analyzed according to both Box counting method and FFT method. The relationship between the fractal dimension and the measurement criteria in X-ray diffraction analysis was discussed with diffraction data obtained under various conditions of the measurement. It was concluded that the fractal analysis is effective for the quantitative evaluation of diffraction data. Box counting method is suitable for evaluation of a whole profile, and FFT method is for that of a fundamental profile. The range of desirable condition of measurement is 1.0≤D≤1.2, where D is a fractal dimension. The appropriate range of measurement becomes 0.01≤Sw/HVB≤0.03, where Sw is the step width and the HVB is the half-value breadth. Stresses with higher precision were obtained from measurements under this new criteria. (author)

  5. Proposed quantitative approach to safety for nuclear power plants in Canada

    International Nuclear Information System (INIS)

    1995-07-01

    A set of quantitative risk and frequency limits plus required processes is proposed to help ensure that a nuclear power plant in Canada meets the qualitative safety objectives defined in ACNS-2 and in IAEA 75-INSAG-3. As emphasized in this report, risks and hence doses are to be reduced below the limits using ALARA (As Low as Reasonably Achievable, economic and social factors being taken into account) or VIA (value-impact analysis) processes unless, in general, calculated risks and hence doses are below recommended de minimis levels. An updated version of ACNS-4, which will be issued as ACNS-21, will incorporate a statement of these limits and objectives as well as assessment criteria and procedures that will facilitate their application. The quantitative approach proposed here is consistent with a growing consensus on the need for, and the elements of, a quantitative approach to risk management of all major activities in an advanced industrial society. The ACNS recommends that the Atomic Energy Control Board adopt the proposed approach as a rational and coherent basis for nuclear power plant safety policy and requirements in Canada. (author). 68 refs., 4 tabs., 1 fig

  6. Proposed quantitative approach to safety for nuclear power plants in Canada

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    A set of quantitative risk and frequency limits plus required processes is proposed to help ensure that a nuclear power plant in Canada meets the qualitative safety objectives defined in ACNS-2 and in IAEA 75-INSAG-3. As emphasized in this report, risks and hence doses are to be reduced below the limits using ALARA (As Low as Reasonably Achievable, economic and social factors being taken into account) or VIA (value-impact analysis) processes unless, in general, calculated risks and hence doses are below recommended de minimis levels. An updated version of ACNS-4, which will be issued as ACNS-21, will incorporate a statement of these limits and objectives as well as assessment criteria and procedures that will facilitate their application. The quantitative approach proposed here is consistent with a growing consensus on the need for, and the elements of, a quantitative approach to risk management of all major activities in an advanced industrial society. The ACNS recommends that the Atomic Energy Control Board adopt the proposed approach as a rational and coherent basis for nuclear power plant safety policy and requirements in Canada. (author). 68 refs., 4 tabs., 1 fig.

  7. Network analysis of quantitative proteomics on asthmatic bronchi: effects of inhaled glucocorticoid treatment

    Directory of Open Access Journals (Sweden)

    Sihlbom Carina

    2011-09-01

    Full Text Available Abstract Background Proteomic studies of respiratory disorders have the potential to identify protein biomarkers for diagnosis and disease monitoring. Utilisation of sensitive quantitative proteomic methods creates opportunities to determine individual patient proteomes. The aim of the current study was to determine if quantitative proteomics of bronchial biopsies from asthmatics can distinguish relevant biological functions and whether inhaled glucocorticoid treatment affects these functions. Methods Endobronchial biopsies were taken from untreated asthmatic patients (n = 12 and healthy controls (n = 3. Asthmatic patients were randomised to double blind treatment with either placebo or budesonide (800 μg daily for 3 months and new biopsies were obtained. Proteins extracted from the biopsies were digested and analysed using isobaric tags for relative and absolute quantitation combined with a nanoLC-LTQ Orbitrap mass spectrometer. Spectra obtained were used to identify and quantify proteins. Pathways analysis was performed using Ingenuity Pathway Analysis to identify significant biological pathways in asthma and determine how the expression of these pathways was changed by treatment. Results More than 1800 proteins were identified and quantified in the bronchial biopsies of subjects. The pathway analysis revealed acute phase response signalling, cell-to-cell signalling and tissue development associations with proteins expressed in asthmatics compared to controls. The functions and pathways associated with placebo and budesonide treatment showed distinct differences, including the decreased association with acute phase proteins as a result of budesonide treatment compared to placebo. Conclusions Proteomic analysis of bronchial biopsy material can be used to identify and quantify proteins using highly sensitive technologies, without the need for pooling of samples from several patients. Distinct pathophysiological features of asthma can be

  8. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  9. Improved Protein Arrays for Quantitative Systems Analysis of the Dynamics of Signaling Pathway Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chin-Rang [National Inst. of Health (NIH), Bethesda, MD (United States). National Heart, Lung and Blood Inst.

    2013-12-11

    Astronauts and workers in nuclear plants who repeatedly exposed to low doses of ionizing radiation (IR, <10 cGy) are likely to incur specific changes in signal transduction and gene expression in various tissues of their body. Remarkable advances in high throughput genomics and proteomics technologies enable researchers to broaden their focus from examining single gene/protein kinetics to better understanding global gene/protein expression profiling and biological pathway analyses, namely Systems Biology. An ultimate goal of systems biology is to develop dynamic mathematical models of interacting biological systems capable of simulating living systems in a computer. This Glue Grant is to complement Dr. Boothman’s existing DOE grant (No. DE-FG02-06ER64186) entitled “The IGF1/IGF-1R-MAPK-Secretory Clusterin (sCLU) Pathway: Mediator of a Low Dose IR-Inducible Bystander Effect” to develop sensitive and quantitative proteomic technology that suitable for low dose radiobiology researches. An improved version of quantitative protein array platform utilizing linear Quantum dot signaling for systematically measuring protein levels and phosphorylation states for systems biology modeling is presented. The signals are amplified by a confocal laser Quantum dot scanner resulting in ~1000-fold more sensitivity than traditional Western blots and show the good linearity that is impossible for the signals of HRP-amplification. Therefore this improved protein array technology is suitable to detect weak responses of low dose radiation. Software is developed to facilitate the quantitative readout of signaling network activities. Kinetics of EGFRvIII mutant signaling was analyzed to quantify cross-talks between EGFR and other signaling pathways.

  10. Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods.

    Science.gov (United States)

    Imbriaco, Massimo; Nappi, Carmela; Puglia, Marta; De Giorgi, Marco; Dell'Aversana, Serena; Cuocolo, Renato; Ponsiglione, Andrea; De Giorgi, Igino; Polito, Maria Vincenza; Klain, Michele; Piscione, Federico; Pace, Leonardo; Cuocolo, Alberto

    2017-10-26

    To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

  11. Quantitative analysis by microchip capillary electrophoresis – current limitations and problem-solving strategies

    NARCIS (Netherlands)

    Revermann, T.; Götz, S.; Künnemeyer, Jens; Karst, U.

    2008-01-01

    Obstacles and possible solutions for the application of microchip capillary electrophoresis in quantitative analysis are described and critically discussed. Differences between the phenomena occurring during conventional capillary electrophoresis and microchip-based capillary electrophoresis are

  12. MR imaging of Minamata disease. Qualitative and quantitative analysis

    International Nuclear Information System (INIS)

    Korogi, Yukunori; Takahashi, Mutsumasa; Sumi, Minako; Hirai, Toshinori; Okuda, Tomoko; Shinzato, Jintetsu; Okajima, Toru.

    1994-01-01

    Minamata disease (MD), a result of methylmercury poisoning, is a neurological illness caused by ingestion of contaminated seafood. We evaluated MR findings of patients with MD qualitatively and quantitatively. Magnetic resonance imaging at 1.5 Tesla was performed in seven patients with MD and in eight control subjects. All of our patients showed typical neurological findings like sensory disturbance, constriction of the visual fields, and ataxia. In the quantitative image analysis, inferior and middle parts of the cerebellar vermis and cerebellar hemispheres were significantly atrophic in comparison with the normal controls. There were no significant differences in measurements of the basis pontis, middle cerebellar peduncles, corpus callosum, or cerebral hemispheres between MD and the normal controls. The calcarine sulci and central sulci were significantly dilated, reflecting atrophy of the visual cortex and postcentral cortex, respectively. The lesions located in the calcarine area, cerebellum, and postcentral gyri were related to three characteristic manifestations of this disease, constriction of the visual fields, ataxia, and sensory disturbance, respectively. MR imaging has proved to be useful in evaluating the CNS abnormalities of methylmercury poisoning. (author)

  13. Barriers, facilitators and preferences for the physical activity of school children. Rationale and methods of a mixed study

    Directory of Open Access Journals (Sweden)

    Martínez-Andrés María

    2012-09-01

    Full Text Available Abstract Background Physical activity interventions in schools environment seem to have shown some effectiveness in the control of the current obesity epidemic in children. However the complexity of behaviors and the diversity of influences related to this problem suggest that we urgently need new lines of insight about how to support comprehensive population strategies of intervention. The aim of this study was to know the perceptions of the children from Cuenca, about their environmental barriers, facilitators and preferences for physical activity. Methods/Design We used a mixed-method design by combining two qualitative methods (analysis of individual drawings and focus groups together with the quantitative measurement of physical activity through accelerometers, in a theoretical sample of 121 children aged 9 and 11 years of schools in the province of Cuenca, Spain. Conclusions Mixed-method study is an appropriate strategy to know the perceptions of children about barriers and facilitators for physical activity, using both qualitative methods for a deeply understanding of their points of view, and quantitative methods for triangulate the discourse of participants with empirical data. We consider that this is an innovative approach that could provide knowledges for the development of more effective interventions to prevent childhood overweight.

  14. Quantitative data analysis methods for 3D microstructure characterization of Solid Oxide Cells

    DEFF Research Database (Denmark)

    Jørgensen, Peter Stanley

    through percolating networks and reaction rates at the triple phase boundaries. Quantitative analysis of microstructure is thus important both in research and development of optimal microstructure design and fabrication. Three dimensional microstructure characterization in particular holds great promise...... for gaining further fundamental understanding of how microstructure affects performance. In this work, methods for automatic 3D characterization of microstructure are studied: from the acquisition of 3D image data by focused ion beam tomography to the extraction of quantitative measures that characterize...... the microstructure. The methods are exemplied by the analysis of Ni-YSZ and LSC-CGO electrode samples. Automatic methods for preprocessing the raw 3D image data are developed. The preprocessing steps correct for errors introduced by the image acquisition by the focused ion beam serial sectioning. Alignment...

  15. Multivariate calibration applied to the quantitative analysis of infrared spectra

    Energy Technology Data Exchange (ETDEWEB)

    Haaland, D.M.

    1991-01-01

    Multivariate calibration methods are very useful for improving the precision, accuracy, and reliability of quantitative spectral analyses. Spectroscopists can more effectively use these sophisticated statistical tools if they have a qualitative understanding of the techniques involved. A qualitative picture of the factor analysis multivariate calibration methods of partial least squares (PLS) and principal component regression (PCR) is presented using infrared calibrations based upon spectra of phosphosilicate glass thin films on silicon wafers. Comparisons of the relative prediction abilities of four different multivariate calibration methods are given based on Monte Carlo simulations of spectral calibration and prediction data. The success of multivariate spectral calibrations is demonstrated for several quantitative infrared studies. The infrared absorption and emission spectra of thin-film dielectrics used in the manufacture of microelectronic devices demonstrate rapid, nondestructive at-line and in-situ analyses using PLS calibrations. Finally, the application of multivariate spectral calibrations to reagentless analysis of blood is presented. We have found that the determination of glucose in whole blood taken from diabetics can be precisely monitored from the PLS calibration of either mind- or near-infrared spectra of the blood. Progress toward the non-invasive determination of glucose levels in diabetics is an ultimate goal of this research. 13 refs., 4 figs.

  16. Quantitative analysis of secretome from adipocytes regulated by insulin

    Institute of Scientific and Technical Information of China (English)

    Hu Zhou; Yuanyuan Xiao; Rongxia Li; Shangyu Hong; Sujun Li; Lianshui Wang; Rong Zeng; Kan Liao

    2009-01-01

    Adipocyte is not only a central player involved in storage and release of energy, but also in regulation of energy metabolism in other organs via secretion of pep-tides and proteins. During the pathogenesis of insulin resistance and type 2 diabetes, adipocytes are subjected to the increased levels of insulin, which may have a major impact on the secretion of adipokines. We have undertaken cleavable isotope-coded affinity tag (clCAT) and label-free quantitation approaches to identify and quantify secretory factors that are differen-tially secreted by 3T3-LI adipocytes with or without insulin treatment. Combination of clCAT and label-free results, there are 317 proteins predicted or annotated as secretory proteins. Among these secretory proteins, 179 proteins and 53 proteins were significantly up-regulated and down-regulated, respectively. A total of 77 reported adipokines were quantified in our study, such as adiponectin, cathepsin D, cystatin C, resistin, and transferrin. Western blot analysis of these adipo-kines confirmed the quantitative results from mass spectrometry, and revealed individualized secreting pat-terns of these proteins by increasing insulin dose. In addition, 240 proteins were newly identified and quanti-fied as secreted proteins from 3T3-L1 adipocytes in our study, most of which were up-regulated upon insulin treatment. Further comprehensive bioinformatics analysis revealed that the secretory proteins in extra-cellular matrix-receptor interaction pathway and glycan structure degradation pathway were significantly up-regulated by insulin stimulation.

  17. Cardiac imaging: working towards fully-automated machine analysis & interpretation.

    Science.gov (United States)

    Slomka, Piotr J; Dey, Damini; Sitek, Arkadiusz; Motwani, Manish; Berman, Daniel S; Germano, Guido

    2017-03-01

    Non-invasive imaging plays a critical role in managing patients with cardiovascular disease. Although subjective visual interpretation remains the clinical mainstay, quantitative analysis facilitates objective, evidence-based management, and advances in clinical research. This has driven developments in computing and software tools aimed at achieving fully automated image processing and quantitative analysis. In parallel, machine learning techniques have been used to rapidly integrate large amounts of clinical and quantitative imaging data to provide highly personalized individual patient-based conclusions. Areas covered: This review summarizes recent advances in automated quantitative imaging in cardiology and describes the latest techniques which incorporate machine learning principles. The review focuses on the cardiac imaging techniques which are in wide clinical use. It also discusses key issues and obstacles for these tools to become utilized in mainstream clinical practice. Expert commentary: Fully-automated processing and high-level computer interpretation of cardiac imaging are becoming a reality. Application of machine learning to the vast amounts of quantitative data generated per scan and integration with clinical data also facilitates a move to more patient-specific interpretation. These developments are unlikely to replace interpreting physicians but will provide them with highly accurate tools to detect disease, risk-stratify, and optimize patient-specific treatment. However, with each technological advance, we move further from human dependence and closer to fully-automated machine interpretation.

  18. A Content Analysis of Quantitative Research in Journal of Marital and Family Therapy: A 10-Year Review.

    Science.gov (United States)

    Parker, Elizabeth O; Chang, Jennifer; Thomas, Volker

    2016-01-01

    We examined the trends of quantitative research over the past 10 years in the Journal of Marital and Family Therapy (JMFT). Specifically, within the JMFT, we investigated the types and trends of research design and statistical analysis within the quantitative research that was published in JMFT from 2005 to 2014. We found that while the amount of peer-reviewed articles have increased over time, the percentage of quantitative research has remained constant. We discussed the types and trends of statistical analysis and the implications for clinical work and training programs in the field of marriage and family therapy. © 2016 American Association for Marriage and Family Therapy.

  19. Online interprofessional education facilitation: A scoping review.

    Science.gov (United States)

    Evans, Sherryn Maree; Ward, Catherine; Reeves, Scott

    2018-04-22

    The use of online media to deliver interprofessional education (IPE) is becoming more prevalent across health professions education settings. Facilitation of IPE activities is known to be critical to the effective delivery of IPE, however, specifics about the nature of online IPE facilitation remains unclear. To explore the health professions education literature to understand the extent, range and nature of research on online IPE facilitation. Scoping review methodology was used to guide a search of four electronic databases for relevant papers. Of the 2095 abstracts initially identified, after screening of both abstracts and full-text papers, 10 studies were selected for inclusion in this review. Following abstraction of key information from each study, a thematic analysis was undertaken. Three key themes emerged to describe the nature of the IPE facilitation literature: (1) types of online IPE facilitation contributions, (2) the experience of online IPE facilitation and (3) personal outcomes of online IPE facilitation. These IPE facilitation themes were particularly focused on facilitation of interprofessional student teams on an asynchronous basis. While the included studies provide some insight into the nature of online IPE facilitation, future research is needed to better understand facilitator contributions, and the facilitation experience and associated outcomes, both relating to synchronous and asynchronous online environments.

  20. Quantitative structure-activity relationship analysis of substituted arylazo pyridone dyes in photocatalytic system: Experimental and theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Dostanić, J., E-mail: jasmina@nanosys.ihtm.bg.ac.rs [University of Belgrade, Institute of Chemistry, Technology and Metallurgy, Department of Catalysis and Chemical Engineering, Njegoševa 12, 11000 Belgrade (Serbia); Lončarević, D. [University of Belgrade, Institute of Chemistry, Technology and Metallurgy, Department of Catalysis and Chemical Engineering, Njegoševa 12, 11000 Belgrade (Serbia); Zlatar, M. [University of Belgrade, Institute of Chemistry, Technology and Metallurgy, Department of Chemistry, Njegoševa 12, 11000 Belgrade (Serbia); Vlahović, F. [University of Belgrade, Innovation center of the Faculty of Chemistry, 11000 Belgrade (Serbia); Jovanović, D.M. [University of Belgrade, Institute of Chemistry, Technology and Metallurgy, Department of Catalysis and Chemical Engineering, Njegoševa 12, 11000 Belgrade (Serbia)

    2016-10-05

    Highlights: • Electronic effects of para substituted arylazo pyridone dyes. • Linear relationship between Hammett σ{sub p} constants and dyes photoreactivity. • The photocatalytic reactions facilitated by el.-acceptors and retarded by el.-donors. • Fukui functions to analyze the reactivity on concurrent sites within a molecule. • Hydroxyl radicals sustain attack from two reaction sites, depending on a substituent type. - Abstract: A series of arylazo pyridone dyes was synthesized by changing the type of the substituent group in the diazo moiety, ranging from strong electron-donating to strong electron-withdrawing groups. The structural and electronic properties of the investigated dyes was calculated at the M062X/6-31 + G(d,p) level of theory. The observed good linear correlations between atomic charges and Hammett σ{sub p} constants provided a basis to discuss the transmission of electronic substituent effects through a dye framework. The reactivity of synthesized dyes was tested through their decolorization efficiency in TiO{sub 2} photocatalytic system (Degussa P-25). Quantitative structure-activity relationship analysis revealed a strong correlation between reactivity of investigated dyes and Hammett substituent constants. The reaction was facilitated by electron-withdrawing groups, and retarded by electron-donating ones. Quantum mechanical calculations was used in order to describe the mechanism of the photocatalytic oxidation reactions of investigated dyes and interpret their reactivities within the framework of the Density Functional Theory (DFT). According to DFT based reactivity descriptors, i.e. Fukui functions and local softness, the active site moves from azo nitrogen atom linked to benzene ring to pyridone carbon atom linked to azo bond, going from dyes with electron-donating groups to dyes with electron-withdrawing groups.

  1. Quantitative structure-activity relationship analysis of substituted arylazo pyridone dyes in photocatalytic system: Experimental and theoretical study

    International Nuclear Information System (INIS)

    Dostanić, J.; Lončarević, D.; Zlatar, M.; Vlahović, F.; Jovanović, D.M.

    2016-01-01

    Highlights: • Electronic effects of para substituted arylazo pyridone dyes. • Linear relationship between Hammett σ_p constants and dyes photoreactivity. • The photocatalytic reactions facilitated by el.-acceptors and retarded by el.-donors. • Fukui functions to analyze the reactivity on concurrent sites within a molecule. • Hydroxyl radicals sustain attack from two reaction sites, depending on a substituent type. - Abstract: A series of arylazo pyridone dyes was synthesized by changing the type of the substituent group in the diazo moiety, ranging from strong electron-donating to strong electron-withdrawing groups. The structural and electronic properties of the investigated dyes was calculated at the M062X/6-31 + G(d,p) level of theory. The observed good linear correlations between atomic charges and Hammett σ_p constants provided a basis to discuss the transmission of electronic substituent effects through a dye framework. The reactivity of synthesized dyes was tested through their decolorization efficiency in TiO_2 photocatalytic system (Degussa P-25). Quantitative structure-activity relationship analysis revealed a strong correlation between reactivity of investigated dyes and Hammett substituent constants. The reaction was facilitated by electron-withdrawing groups, and retarded by electron-donating ones. Quantum mechanical calculations was used in order to describe the mechanism of the photocatalytic oxidation reactions of investigated dyes and interpret their reactivities within the framework of the Density Functional Theory (DFT). According to DFT based reactivity descriptors, i.e. Fukui functions and local softness, the active site moves from azo nitrogen atom linked to benzene ring to pyridone carbon atom linked to azo bond, going from dyes with electron-donating groups to dyes with electron-withdrawing groups.

  2. Quantitative analysis of terahertz spectra for illicit drugs using adaptive-range micro-genetic algorithm

    Science.gov (United States)

    Chen, Yi; Ma, Yong; Lu, Zheng; Peng, Bei; Chen, Qin

    2011-08-01

    In the field of anti-illicit drug applications, many suspicious mixture samples might consist of various drug components—for example, a mixture of methamphetamine, heroin, and amoxicillin—which makes spectral identification very difficult. A terahertz spectroscopic quantitative analysis method using an adaptive range micro-genetic algorithm with a variable internal population (ARVIPɛμGA) has been proposed. Five mixture cases are discussed using ARVIPɛμGA driven quantitative terahertz spectroscopic analysis in this paper. The devised simulation results show agreement with the previous experimental results, which suggested that the proposed technique has potential applications for terahertz spectral identifications of drug mixture components. The results show agreement with the results obtained using other experimental and numerical techniques.

  3. Quantitative analysis with energy dispersive X-ray fluorescence analyser

    International Nuclear Information System (INIS)

    Kataria, S.K.; Kapoor, S.S.; Lal, M.; Rao, B.V.N.

    1977-01-01

    Quantitative analysis of samples using radioisotope excited energy dispersive x-ray fluorescence system is described. The complete set-up is built around a locally made Si(Li) detector x-ray spectrometer with an energy resolution of 220 eV at 5.94 KeV. The photopeaks observed in the x-ray fluorescence spectra are fitted with a Gaussian function and the intensities of the characteristic x-ray lines are extracted, which in turn are used for calculating the elemental concentrations. The results for a few typical cases are presented. (author)

  4. FACILITATING INTEGRATED SPATIO-TEMPORAL VISUALIZATION AND ANALYSIS OF HETEROGENEOUS ARCHAEOLOGICAL AND PALAEOENVIRONMENTAL RESEARCH DATA

    Directory of Open Access Journals (Sweden)

    C. Willmes

    2012-07-01

    Full Text Available In the context of the Collaborative Research Centre 806 "Our way to Europe" (CRC806, a research database is developed for integrating data from the disciplines of archaeology, the geosciences and the cultural sciences to facilitate integrated access to heterogeneous data sources. A practice-oriented data integration concept and its implementation is presented in this contribution. The data integration approach is based on the application of Semantic Web Technology and is applied to the domains of archaeological and palaeoenvironmental data. The aim is to provide integrated spatio-temporal access to an existing wealth of data to facilitate research on the integrated data basis. For the web portal of the CRC806 research database (CRC806-Database, a number of interfaces and applications have been evaluated, developed and implemented for exposing the data to interactive analysis and visualizations.

  5. Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe

    International Nuclear Information System (INIS)

    Vekemans, B.; Vincze, L.; Somogyi, A.; Drakopoulos, M.; Kempenaers, L.; Simionovici, A.; Adams, F.

    2003-01-01

    The new ID18F end-station at the European synchrotron radiation facility (ESRF) in Grenoble (France) is dedicated to sensitive and accurate quantitative micro-X-ray fluorescence (XRF) analysis at the ppm level with accuracy better than 10% for elements with atomic numbers above 18. For accurate quantitative analysis, given a high level of instrumental stability, major steps are the extraction and conversion of experimental X-ray line intensities into elemental concentrations. For this purpose a two-step quantification approach was adopted. In the first step, the collected XRF spectra are deconvoluted on the basis of a non-linear least-squares fitting algorithm (AXIL). The extracted characteristic line intensities are then used as input for a detailed Monte Carlo (MC) simulation code dedicated to XRF spectroscopy taking into account specific experimental conditions (excitation/detection) as well as sample characteristics (absorption and enhancement effects, sample topology, heterogeneity etc.). The iterative use of the MC code gives a 'no-compromise' solution for the quantification problem

  6. Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vekemans, B. E-mail: vekemans@uia.ua.ac.be; Vincze, L.; Somogyi, A.; Drakopoulos, M.; Kempenaers, L.; Simionovici, A.; Adams, F

    2003-01-01

    The new ID18F end-station at the European synchrotron radiation facility (ESRF) in Grenoble (France) is dedicated to sensitive and accurate quantitative micro-X-ray fluorescence (XRF) analysis at the ppm level with accuracy better than 10% for elements with atomic numbers above 18. For accurate quantitative analysis, given a high level of instrumental stability, major steps are the extraction and conversion of experimental X-ray line intensities into elemental concentrations. For this purpose a two-step quantification approach was adopted. In the first step, the collected XRF spectra are deconvoluted on the basis of a non-linear least-squares fitting algorithm (AXIL). The extracted characteristic line intensities are then used as input for a detailed Monte Carlo (MC) simulation code dedicated to XRF spectroscopy taking into account specific experimental conditions (excitation/detection) as well as sample characteristics (absorption and enhancement effects, sample topology, heterogeneity etc.). The iterative use of the MC code gives a 'no-compromise' solution for the quantification problem.

  7. Application of non-quantitative modelling in the analysis of a network warfare environment

    CSIR Research Space (South Africa)

    Veerasamy, N

    2008-07-01

    Full Text Available based on the use of secular associations, chronological origins, linked concepts, categorizations and context specifications. This paper proposes the use of non-quantitative methods through a morphological analysis to better explore and define...

  8. Quantitative analysis of protein-ligand interactions by NMR.

    Science.gov (United States)

    Furukawa, Ayako; Konuma, Tsuyoshi; Yanaka, Saeko; Sugase, Kenji

    2016-08-01

    Protein-ligand interactions have been commonly studied through static structures of the protein-ligand complex. Recently, however, there has been increasing interest in investigating the dynamics of protein-ligand interactions both for fundamental understanding of the underlying mechanisms and for drug development. NMR is a versatile and powerful tool, especially because it provides site-specific quantitative information. NMR has widely been used to determine the dissociation constant (KD), in particular, for relatively weak interactions. The simplest NMR method is a chemical-shift titration experiment, in which the chemical-shift changes of a protein in response to ligand titration are measured. There are other quantitative NMR methods, but they mostly apply only to interactions in the fast-exchange regime. These methods derive the dissociation constant from population-averaged NMR quantities of the free and bound states of a protein or ligand. In contrast, the recent advent of new relaxation-based experiments, including R2 relaxation dispersion and ZZ-exchange, has enabled us to obtain kinetic information on protein-ligand interactions in the intermediate- and slow-exchange regimes. Based on R2 dispersion or ZZ-exchange, methods that can determine the association rate, kon, dissociation rate, koff, and KD have been developed. In these approaches, R2 dispersion or ZZ-exchange curves are measured for multiple samples with different protein and/or ligand concentration ratios, and the relaxation data are fitted to theoretical kinetic models. It is critical to choose an appropriate kinetic model, such as the two- or three-state exchange model, to derive the correct kinetic information. The R2 dispersion and ZZ-exchange methods are suitable for the analysis of protein-ligand interactions with a micromolar or sub-micromolar dissociation constant but not for very weak interactions, which are typical in very fast exchange. This contrasts with the NMR methods that are used

  9. Empowering the crowd: faculty discourse strategies for facilitating student reasoning in large lecture

    Science.gov (United States)

    Demaree, Dedra

    2012-02-01

    Oregon State University (OSU) has restructured its introductory calculus-based sequence including reformed curriculum modeled after the Interactive Science Learning Environment (ISLE). ISLE is driven by an experimental cycle roughly summarized as: observe phenomena, find patterns and devise explanations, test explanations, develop a model, apply the model to new observations. In implementing ISLE at OSU we have chosen to focus on student scientific reasoning, specifically student ability to develop and test models, make explicit judgments on how to approach open-ended tasks, and take an authoritative role in knowledge development. In order to achieve these goals, the lecture course heavily utilizes social engagement. During large-lecture group work, emphasis is placed on facilitating student discourse about issues such as what systems to choose or how to define an open-ended problem. Instructional strategies are aimed at building off the group discourse to create a full-class community where knowledge is developed through collaboration with peers. We are achieving these goals along with an increase in measured student conceptual knowledge and traditional problem solving abilities, and no loss of content coverage. It is an ongoing effort to understand ``best'' instructional strategies and to facilitate new faculty when they teach the curriculum. Our research has focused on understanding how to facilitate activities that promote this form of discourse. We have quantitative analysis of engagement based on video data, qualitative analysis of dialogue from audio data, classroom observations by an external researcher, and survey data. In this session we share a subset of what we have learned about how to engage students in scientific reasoning discourse during large lecture, both at the group-work and full-class level.

  10. Gender analysis of factors affecting facilitation of agricultural ...

    African Journals Online (AJOL)

    It ascertained the perception of the gender groups on the organizational, job related and ... and ensure balanced working conditions for both men and women facilitators in the NFDP III. This will help to ultimately improve their job performance.

  11. Quantitative risk analysis preoperational of gas pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Manfredi, Carlos; Bispo, Gustavo G.; Esteves, Alvaro [Gie S.A., Buenos Aires (Argentina)

    2009-07-01

    The purpose of this analysis is to predict how it can be affected the individual risk and the public's general security due to the operation of a gas pipeline. In case that the single or social risks are considered intolerable, compared with the international standards, to be recommended measures of mitigation of the risk associated to the operation until levels that can be considered compatible with the best practices in the industry. The quantitative risk analysis calculates the probability of occurrence of an event based on the frequency of occurrence of the same one and it requires a complex mathematical treatment. The present work has as objective to develop a calculation methodology based on the previously mentioned publication. This calculation methodology is centered in defining the frequencies of occurrence of events, according to representative database of each case in study. Besides, it settles down the consequences particularly according to the considerations of each area and the different possibilities of interferences with the gas pipeline in study. For each one of the interferences a typical curve of ignition probabilities is developed in function from the distance to the pipe. (author)

  12. SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

    International Nuclear Information System (INIS)

    Wahi-Anwar, M; Lo, P; Kim, H; Brown, M; McNitt-Gray, M

    2016-01-01

    Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifies the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel

  13. SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Wahi-Anwar, M; Lo, P; Kim, H; Brown, M; McNitt-Gray, M [UCLA Radiological Sciences, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifies the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel

  14. Tau-U: A Quantitative Approach for Analysis of Single-Case Experimental Data in Aphasia.

    Science.gov (United States)

    Lee, Jaime B; Cherney, Leora R

    2018-03-01

    Tau-U is a quantitative approach for analyzing single-case experimental design (SCED) data. It combines nonoverlap between phases with intervention phase trend and can correct for a baseline trend (Parker, Vannest, & Davis, 2011). We demonstrate the utility of Tau-U by comparing it with the standardized mean difference approach (Busk & Serlin, 1992) that is widely reported within the aphasia SCED literature. Repeated writing measures from 3 participants with chronic aphasia who received computer-based writing treatment are analyzed visually and quantitatively using both Tau-U and the standardized mean difference approach. Visual analysis alone was insufficient for determining an effect between the intervention and writing improvement. The standardized mean difference yielded effect sizes ranging from 4.18 to 26.72 for trained items and 1.25 to 3.20 for untrained items. Tau-U yielded significant (p data from 2 of 3 participants. Tau-U has the unique advantage of allowing for the correction of an undesirable baseline trend. Although further study is needed, Tau-U shows promise as a quantitative approach to augment visual analysis of SCED data in aphasia.

  15. Quantitative Analysis of Ductile Iron Microstructure – A Comparison of Selected Methods for Assessment

    Directory of Open Access Journals (Sweden)

    Mrzygłód B.

    2013-09-01

    Full Text Available Stereological description of dispersed microstructure is not an easy task and remains the subject of continuous research. In its practical aspect, a correct stereological description of this type of structure is essential for the analysis of processes of coagulation and spheroidisation, or for studies of relationships between structure and properties. One of the most frequently used methods for an estimation of the density Nv and size distribution of particles is the Scheil - Schwartz - Saltykov method. In this article, the authors present selected methods for quantitative assessment of ductile iron microstructure, i.e. the Scheil - Schwartz - Saltykov method, which allows a quantitative description of three-dimensional sets of solids using measurements and counts performed on two-dimensional cross-sections of these sets (microsections and quantitative description of three-dimensional sets of solids by X-ray computed microtomography, which is an interesting alternative for structural studies compared to traditional methods of microstructure imaging since, as a result, the analysis provides a three-dimensional imaging of microstructures examined.

  16. The Digital Image Processing And Quantitative Analysis In Microscopic Image Characterization

    International Nuclear Information System (INIS)

    Ardisasmita, M. Syamsa

    2000-01-01

    Many electron microscopes although have produced digital images, but not all of them are equipped with a supporting unit to process and analyse image data quantitatively. Generally the analysis of image has to be made visually and the measurement is realized manually. The development of mathematical method for geometric analysis and pattern recognition, allows automatic microscopic image analysis with computer. Image processing program can be used for image texture and structure periodic analysis by the application of Fourier transform. Because the development of composite materials. Fourier analysis in frequency domain become important for measure the crystallography orientation. The periodic structure analysis and crystal orientation are the key to understand many material properties like mechanical strength. stress, heat conductivity, resistance, capacitance and other material electric and magnetic properties. In this paper will be shown the application of digital image processing in microscopic image characterization and analysis in microscopic image

  17. HPTLC Hyphenated with FTIR: Principles, Instrumentation and Qualitative Analysis and Quantitation

    Science.gov (United States)

    Cimpoiu, Claudia

    In recent years, much effort has been devoted to the coupling of high-performance thin-layer chromatography (HPTLC) with spectrometric methods because of the robustness and simplicity of HPTLC and the need for detection techniques that provide identification and determination of sample constituents. IR is one of the spectroscopic methods that have been coupled with HPTLC. IR spectroscopy has a high potential for the elucidation of molecular structures, and the characteristic absorption bands can be used for compound-specific detection. HPTLC-FTIR coupled method has been widely used in the modern laboratories for the qualitative and quantitative analysis. The potential of this method is demonstrated by its application in different fields of analysis such as drug analysis, forensic analysis, food analysis, environmental analysis, biological analysis, etc. The hyphenated HPTLC-FTIR technique will be developed in the future with the aim of taking full advantage of this method.

  18. Application of neural networks to quantitative spectrometry analysis

    International Nuclear Information System (INIS)

    Pilato, V.; Tola, F.; Martinez, J.M.; Huver, M.

    1999-01-01

    Accurate quantitative analysis of complex spectra (fission and activation products), relies upon experts' knowledge. In some cases several hours, even days of tedious calculations are needed. This is because current software is unable to solve deconvolution problems when several rays overlap. We have shown that such analysis can be correctly handled by a neural network, and the procedure can be automated with minimum laboratory measurements for networks training, as long as all the elements of the analysed solution figure in the training set and provided that adequate scaling of input data is performed. Once the network has been trained, analysis is carried out in a few seconds. On submitting to a test between several well-known laboratories, where unknown quantities of 57 Co, 58 Co, 85 Sr, 88 Y, 131 I, 139 Ce, 141 Ce present in a sample had to be determined, the results yielded by our network classed it amongst the best. The method is described, including experimental device and measures, training set designing, relevant input parameters definition, input data scaling and networks training. Main results are presented together with a statistical model allowing networks error prediction

  19. Quantitative imaging analysis of posterior fossa ependymoma location in children.

    Science.gov (United States)

    Sabin, Noah D; Merchant, Thomas E; Li, Xingyu; Li, Yimei; Klimo, Paul; Boop, Frederick A; Ellison, David W; Ogg, Robert J

    2016-08-01

    Imaging descriptions of posterior fossa ependymoma in children have focused on magnetic resonance imaging (MRI) signal and local anatomic relationships with imaging location only recently used to classify these neoplasms. We developed a quantitative method for analyzing the location of ependymoma in the posterior fossa, tested its effectiveness in distinguishing groups of tumors, and examined potential associations of distinct tumor groups with treatment and prognostic factors. Pre-operative MRI examinations of the brain for 38 children with histopathologically proven posterior fossa ependymoma were analyzed. Tumor margin contours and anatomic landmarks were manually marked and used to calculate the centroid of each tumor. Landmarks were used to calculate a transformation to align, scale, and rotate each patient's image coordinates to a common coordinate space. Hierarchical cluster analysis of the location and morphological variables was performed to detect multivariate patterns in tumor characteristics. The ependymomas were also characterized as "central" or "lateral" based on published radiological criteria. Therapeutic details and demographic, recurrence, and survival information were obtained from medical records and analyzed with the tumor location and morphology to identify prognostic tumor characteristics. Cluster analysis yielded two distinct tumor groups based on centroid location The cluster groups were associated with differences in PFS (p = .044), "central" vs. "lateral" radiological designation (p = .035), and marginally associated with multiple operative interventions (p = .064). Posterior fossa ependymoma can be objectively classified based on quantitative analysis of tumor location, and these classifications are associated with prognostic and treatment factors.

  20. Hand Fatigue Analysis Using Quantitative Evaluation of Variability in Drawing Patterns

    Directory of Open Access Journals (Sweden)

    mohamadali Sanjari

    2015-02-01

    Full Text Available Background & aim: Muscle fatigue is defined as the reduced power generation capacity of a muscle or muscle group after activity which can lead to a variety of lesions. The purpose of the present study was to define the fatigue analysis by quantitative analysis using drawing patterns. Methods: the present cross-sectional study was conducted on 37 healthy volunteers (6 men and 31 women aged 18-30 years. Before & immediately after a fatigue protocol, quantitative assessment of hand drawing skills was performed by drawing repeated, overlapping, and concentric circles. The test was conducted in three sessions with an interval of 48-72 hours. Drawing was recorded by a digital tablet. Data were statistically analyzed using paired t-test and repeated measure ANOVA. Result: In drawing time series data analysis, at fatigue level of 100%, the variables standard deviation along x axis (SDx, standard deviation of velocity on both x and y axis (SDVx and SDVy and resultant vector velocity standard deviation (SDVR, showed significant differences after fatigue (P<0.05. In comparison of variables after the three fatigue levels, SDx showed significant difference (P<0.05. Conclusions: structurally full fatigue showed significant differences with other levels of fatigue, so it contributed to significant variability in drawing parameters. The method used in the present study recognized the fatigue in high frequency motion as well.

  1. An integrated workflow for robust alignment and simplified quantitative analysis of NMR spectrometry data

    Directory of Open Access Journals (Sweden)

    Dommisse Roger

    2011-10-01

    Full Text Available Abstract Background Nuclear magnetic resonance spectroscopy (NMR is a powerful technique to reveal and compare quantitative metabolic profiles of biological tissues. However, chemical and physical sample variations make the analysis of the data challenging, and typically require the application of a number of preprocessing steps prior to data interpretation. For example, noise reduction, normalization, baseline correction, peak picking, spectrum alignment and statistical analysis are indispensable components in any NMR analysis pipeline. Results We introduce a novel suite of informatics tools for the quantitative analysis of NMR metabolomic profile data. The core of the processing cascade is a novel peak alignment algorithm, called hierarchical Cluster-based Peak Alignment (CluPA. The algorithm aligns a target spectrum to the reference spectrum in a top-down fashion by building a hierarchical cluster tree from peak lists of reference and target spectra and then dividing the spectra into smaller segments based on the most distant clusters of the tree. To reduce the computational time to estimate the spectral misalignment, the method makes use of Fast Fourier Transformation (FFT cross-correlation. Since the method returns a high-quality alignment, we can propose a simple methodology to study the variability of the NMR spectra. For each aligned NMR data point the ratio of the between-group and within-group sum of squares (BW-ratio is calculated to quantify the difference in variability between and within predefined groups of NMR spectra. This differential analysis is related to the calculation of the F-statistic or a one-way ANOVA, but without distributional assumptions. Statistical inference based on the BW-ratio is achieved by bootstrapping the null distribution from the experimental data. Conclusions The workflow performance was evaluated using a previously published dataset. Correlation maps, spectral and grey scale plots show clear

  2. An integrated workflow for robust alignment and simplified quantitative analysis of NMR spectrometry data.

    Science.gov (United States)

    Vu, Trung N; Valkenborg, Dirk; Smets, Koen; Verwaest, Kim A; Dommisse, Roger; Lemière, Filip; Verschoren, Alain; Goethals, Bart; Laukens, Kris

    2011-10-20

    Nuclear magnetic resonance spectroscopy (NMR) is a powerful technique to reveal and compare quantitative metabolic profiles of biological tissues. However, chemical and physical sample variations make the analysis of the data challenging, and typically require the application of a number of preprocessing steps prior to data interpretation. For example, noise reduction, normalization, baseline correction, peak picking, spectrum alignment and statistical analysis are indispensable components in any NMR analysis pipeline. We introduce a novel suite of informatics tools for the quantitative analysis of NMR metabolomic profile data. The core of the processing cascade is a novel peak alignment algorithm, called hierarchical Cluster-based Peak Alignment (CluPA). The algorithm aligns a target spectrum to the reference spectrum in a top-down fashion by building a hierarchical cluster tree from peak lists of reference and target spectra and then dividing the spectra into smaller segments based on the most distant clusters of the tree. To reduce the computational time to estimate the spectral misalignment, the method makes use of Fast Fourier Transformation (FFT) cross-correlation. Since the method returns a high-quality alignment, we can propose a simple methodology to study the variability of the NMR spectra. For each aligned NMR data point the ratio of the between-group and within-group sum of squares (BW-ratio) is calculated to quantify the difference in variability between and within predefined groups of NMR spectra. This differential analysis is related to the calculation of the F-statistic or a one-way ANOVA, but without distributional assumptions. Statistical inference based on the BW-ratio is achieved by bootstrapping the null distribution from the experimental data. The workflow performance was evaluated using a previously published dataset. Correlation maps, spectral and grey scale plots show clear improvements in comparison to other methods, and the down

  3. Forensic toxicology in drug-facilitated sexual assault.

    Science.gov (United States)

    Dinis-Oliveira, Ricardo Jorge; Magalhães, Teresa

    2013-09-01

    The low rates of reporting, prosecution and conviction that characterize sexual assault, is likely even more evident in drug-facilitated cases. Typically, in these crimes, victims are incapacitated and left unable to resist sexual advances, unconscious, unable to fight off the abuser or to say "no" and unable to clearly remember the circumstances surrounding the events due to anterograde amnesia. The consequence is the delay in performing toxicological analysis aggravated by the reluctance of the victim to disclose the crime. Moreover since "date rape drugs" are often consumed with ethanol and exhibit similar toxicodynamic effects, the diagnosis is erroneously performed as being classical ethanol intoxication. Therefore, it is imperative to rapidly consider toxicological analysis in drug-facilitated sexual assaults. The major focus of this review is to harmonize practical approaches and guidelines to rapidly uncover drug-facilitated sexual assault, namely issues related to when to perform toxicological analysis, toxicological requests, samples to be collected, storage, preservation and transport precautions and xenobiotics or endobiotics to be analyzed.

  4. Deterministic quantitative risk assessment development

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Jane; Colquhoun, Iain [PII Pipeline Solutions Business of GE Oil and Gas, Cramlington Northumberland (United Kingdom)

    2009-07-01

    Current risk assessment practice in pipeline integrity management is to use a semi-quantitative index-based or model based methodology. This approach has been found to be very flexible and provide useful results for identifying high risk areas and for prioritizing physical integrity assessments. However, as pipeline operators progressively adopt an operating strategy of continual risk reduction with a view to minimizing total expenditures within safety, environmental, and reliability constraints, the need for quantitative assessments of risk levels is becoming evident. Whereas reliability based quantitative risk assessments can be and are routinely carried out on a site-specific basis, they require significant amounts of quantitative data for the results to be meaningful. This need for detailed and reliable data tends to make these methods unwieldy for system-wide risk k assessment applications. This paper describes methods for estimating risk quantitatively through the calibration of semi-quantitative estimates to failure rates for peer pipeline systems. The methods involve the analysis of the failure rate distribution, and techniques for mapping the rate to the distribution of likelihoods available from currently available semi-quantitative programs. By applying point value probabilities to the failure rates, deterministic quantitative risk assessment (QRA) provides greater rigor and objectivity than can usually be achieved through the implementation of semi-quantitative risk assessment results. The method permits a fully quantitative approach or a mixture of QRA and semi-QRA to suit the operator's data availability and quality, and analysis needs. For example, consequence analysis can be quantitative or can address qualitative ranges for consequence categories. Likewise, failure likelihoods can be output as classical probabilities or as expected failure frequencies as required. (author)

  5. Quantitative morphometric analysis for the tectonic characterisation of northern Tunisia.

    Science.gov (United States)

    Camafort, Miquel; Pérez-Peña, José Vicente; Booth-Rea, Guillermo; Ranero, César R.; Gràcia, Eulàlia; Azañón, José Miguel; Melki, Fetheddine; Ouadday, Mohamed

    2016-04-01

    Northern Tunisia is characterized by low deformation rates and low to moderate seismicity. Although instrumental seismicity reaches maximum magnitudes of Mw 5.5, some historical earthquakes have occurred with catastrophic consequences in this region. Aiming to improve our knowledge of active tectonics in Tunisia, we carried out both a quantitative morphometric analysis and field study in the north-western region. We applied different morphometric tools, like river profiles, knickpoint analysis, hypsometric curves and integrals and drainage pattern anomalies in order to differentiate between zones with high or low recent tectonic activity. This analysis helps identifying uplift and subsidence zones, which we relate to fault activity. Several active faults in a sparse distribution were identified. A selected sector was studied with a field campaign to test the results obtained with the quantitative analysis. During the fieldwork we identified geological evidence of recent activity and a considerable seismogenic potential along El Alia-Teboursouk (ETF) and Dkhila (DF) faults. The ETF fault could be responsible of one of the most devastating historical earthquakes in northern Tunisia that destroyed Utique in 412 A.D. Geological evidence include fluvial terraces folded by faults, striated and cracked pebbles, clastic dikes, sand volcanoes, coseismic cracks, etc. Although not reflected in the instrumental seismicity, our results support an important seismic hazard, evidenced by the several active tectonic structures identified and the two seismogenic faults described. After obtaining the current active tectonic framework of Tunisia we discuss our results within the western Mediterranean trying to contribute to the understanding of the western Mediterranean tectonic context. With our results, we suggest that the main reason explaining the sparse and scarce seismicity of the area in contrast with the adjacent parts of the Nubia-Eurasia boundary is due to its extended

  6. Economic analysis of light brown apple moth using GIS and quantitative modeling

    Science.gov (United States)

    Glenn Fowler; Lynn Garrett; Alison Neeley; Roger Magarey; Dan Borchert; Brian. Spears

    2011-01-01

    We conducted an economic analysis of the light brown apple moth (LBAM), (piphyas postvittana (Walker)), whose presence in California has resulted in a regulatory program. Our objective was to quantitatively characterize the economic costs to apple, grape, orange, and pear crops that would result from LBAM's introduction into the continental...

  7. Quantitative analysis of exercise 201Tl myocardial emission CT in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Okada, Mitsuhiro; Kawai, Naoki; Yamamoto, Shuhei

    1984-01-01

    The clinical usefulness of quantitative analysis of exercise thallium-201 myocardial emission computed tomography (ECT) was evaluated in coronary artery disease (CAD). The subjects consisted of 20 CAD patients and five normal controls. All CAD patients underwent coronary angiography. Tomographic thallium-201 myocardial imaging was performed with a rotating gamma camera, and long-axial and short-axial myocardial images of the left ventricle were reconstructed. The tomographic images were interpreted quantitatively using circumferential profile analysis. Based on features of regional myocardial thallium-201 kinetics, two types of abnormalities were studied: (1) diminished initial distribution (stress defect) and (2) slow washout of thallium-201, as evidenced by patients' initial thallium-201 uptake and 3-hour washout rate profiles which fell below the normal limits, respectively. Two diagnostic criteria including the stress defect and a combination of the stress defect and slow washout were used to detect coronary artery lesions of significance (>=75 % luminal narrowing). The ischemic volumes were also evaluated by quantitative analysis using thallium-201 ECT. The diagnostic accuracy of the stress defect criterion was 95 % for left anterior descending, 90 % for right, and 70 % for left circumflex coronary artery lesions. The combined criteria of the stress defect and slow washout increased detection sensitivity with a moderate loss of specificity for identifying individual coronary artery lesion. A relatively high diagnostic accuracy was obtained using the stress defect criterion for multiple vessel disease (75 %). Ischemic myocardial volume was significantly larger in triple vessel than in single vessel disease (p < 0.05) using the combined criteria. It was concluded that quantitative analysis of exercise thallium-201 myocardial ECT images proves useful for evaluating coronary artery lesions. (author)

  8. Rapid Determination of Lymphogranuloma Venereum Serovars of Chlamydia trachomatis by Quantitative High-Resolution Melt Analysis (HRMA)

    Science.gov (United States)

    Stevens, Matthew P.; Garland, Suzanne M.; Zaia, Angelo M.; Tabrizi, Sepehr N.

    2012-01-01

    A quantitative high-resolution melt analysis assay was developed to differentiate lymphogranuloma venereum-causing serovars of Chlamydia trachomatis (L1 to L3) from other C. trachomatis serovars (D to K). The detection limit of this assay is approximately 10 copies per reaction, comparable to the limits of other quantitative-PCR-based methods. PMID:22933594

  9. Quantitative analysis of the anti-noise performance of an m-sequence in an electromagnetic method

    Science.gov (United States)

    Yuan, Zhe; Zhang, Yiming; Zheng, Qijia

    2018-02-01

    An electromagnetic method with a transmitted waveform coded by an m-sequence achieved better anti-noise performance compared to the conventional manner with a square-wave. The anti-noise performance of the m-sequence varied with multiple coding parameters; hence, a quantitative analysis of the anti-noise performance for m-sequences with different coding parameters was required to optimize them. This paper proposes the concept of an identification system, with the identified Earth impulse response obtained by measuring the system output with the input of the voltage response. A quantitative analysis of the anti-noise performance of the m-sequence was achieved by analyzing the amplitude-frequency response of the corresponding identification system. The effects of the coding parameters on the anti-noise performance are summarized by numerical simulation, and their optimization is further discussed in our conclusions; the validity of the conclusions is further verified by field experiment. The quantitative analysis method proposed in this paper provides a new insight into the anti-noise mechanism of the m-sequence, and could be used to evaluate the anti-noise performance of artificial sources in other time-domain exploration methods, such as the seismic method.

  10. An artificial neural network approach to laser-induced breakdown spectroscopy quantitative analysis

    International Nuclear Information System (INIS)

    D’Andrea, Eleonora; Pagnotta, Stefano; Grifoni, Emanuela; Lorenzetti, Giulia; Legnaioli, Stefano; Palleschi, Vincenzo; Lazzerini, Beatrice

    2014-01-01

    The usual approach to laser-induced breakdown spectroscopy (LIBS) quantitative analysis is based on the use of calibration curves, suitably built using appropriate reference standards. More recently, statistical methods relying on the principles of artificial neural networks (ANN) are increasingly used. However, ANN analysis is often used as a ‘black box’ system and the peculiarities of the LIBS spectra are not exploited fully. An a priori exploration of the raw data contained in the LIBS spectra, carried out by a neural network to learn what are the significant areas of the spectrum to be used for a subsequent neural network delegated to the calibration, is able to throw light upon important information initially unknown, although already contained within the spectrum. This communication will demonstrate that an approach based on neural networks specially taylored for dealing with LIBS spectra would provide a viable, fast and robust method for LIBS quantitative analysis. This would allow the use of a relatively limited number of reference samples for the training of the network, with respect to the current approaches, and provide a fully automatizable approach for the analysis of a large number of samples. - Highlights: • A methodological approach to neural network analysis of LIBS spectra is proposed. • The architecture of the network and the number of inputs are optimized. • The method is tested on bronze samples already analyzed using a calibration-free LIBS approach. • The results are validated, compared and discussed

  11. Quantitative analysis of contrast-enhanced ultrasonography of the bowel wall can predict disease activity in inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Romanini, Laura, E-mail: laura.romanini@libero.it [Department of Radiology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Passamonti, Matteo, E-mail: matteopassamonti@gmail.com [Department of Radiology-AO Provincia di Lodi, Via Fissiraga, 15, 26900 Lodi (Italy); Navarria, Mario, E-mail: navarria.mario@tiscali.it [Department of Radiology-ASL Vallecamonica-Sebino, Via Manzoni 142, 25040 Esine, BS (Italy); Lanzarotto, Francesco, E-mail: francesco.lanzarotto@spedalicivili.brescia.it [Department of Gastroenterology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Villanacci, Vincenzo, E-mail: villanac@alice.it [Department of Pathology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Grazioli, Luigi, E-mail: radiologia1@spedalicivili.brescia.it [Department of Radiology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Calliada, Fabrizio, E-mail: fabrizio.calliada@gmail.com [Department of Radiology, University of Pavia, Viale Camillo Golgi 19, 27100 Pavia (Italy); Maroldi, Roberto, E-mail: rmaroldi@gmail.com [Department of Radiology, University of Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy)

    2014-08-15

    Purpose: To evaluate the accuracy of quantitative analysis of bowel wall enhancement in inflammatory bowel disease (IBD) with contrast enhanced ultrasound (CEUS) by comparing the results with vascular density in a biopsy sample from the same area of the intestinal tract, and to determine the usefulness of this analysis for the prediction of disease activity. Materials and methods: This prospective study was approved by our institute's ethics committee and all patients gave written informed consent. We enrolled 33 consecutive adult patients undergoing colonoscopy and biopsy for IBD. All patients underwent CEUS and the results were quantitatively analyzed. Vessel count per high-power field on biopsy specimens was compared with colonoscopy, baseline ultrasonography, and CEUS findings, and with analysis of peak intensity, time to peak, regional blood volume, mean transit time, and regional blood flow. Results in patients with high and low vascular density were compared using Fisher's test, t-test, Pearson's correlation test, and receiver operating characteristic curve (ROC) analysis. Cutoff values were determined using ROC analysis, and sensitivity and specificity were calculated. Results: High vascular density (>265 vessels per field) on histological examination was significantly correlated with active disease on colonoscopy, baseline ultrasonography, and CEUS (p < .0001). Quantitative analysis showed a higher enhancement peak, a shorter time to peak enhancement, a higher regional blood flow and regional blood volume in patients with high vascular density than in those with low vascular density. Cutoff values to distinguish between active and inactive disease were identified for peak enhancement (>40.5%), and regional blood flow (>54.8 ml/min). Conclusion: Quantitative analysis of CEUS data correlates with disease activity as determined by vascular density. Quantitative parameters of CEUS can be used to predict active disease with high sensitivity and

  12. Quantitative analysis of contrast-enhanced ultrasonography of the bowel wall can predict disease activity in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Romanini, Laura; Passamonti, Matteo; Navarria, Mario; Lanzarotto, Francesco; Villanacci, Vincenzo; Grazioli, Luigi; Calliada, Fabrizio; Maroldi, Roberto

    2014-01-01

    Purpose: To evaluate the accuracy of quantitative analysis of bowel wall enhancement in inflammatory bowel disease (IBD) with contrast enhanced ultrasound (CEUS) by comparing the results with vascular density in a biopsy sample from the same area of the intestinal tract, and to determine the usefulness of this analysis for the prediction of disease activity. Materials and methods: This prospective study was approved by our institute's ethics committee and all patients gave written informed consent. We enrolled 33 consecutive adult patients undergoing colonoscopy and biopsy for IBD. All patients underwent CEUS and the results were quantitatively analyzed. Vessel count per high-power field on biopsy specimens was compared with colonoscopy, baseline ultrasonography, and CEUS findings, and with analysis of peak intensity, time to peak, regional blood volume, mean transit time, and regional blood flow. Results in patients with high and low vascular density were compared using Fisher's test, t-test, Pearson's correlation test, and receiver operating characteristic curve (ROC) analysis. Cutoff values were determined using ROC analysis, and sensitivity and specificity were calculated. Results: High vascular density (>265 vessels per field) on histological examination was significantly correlated with active disease on colonoscopy, baseline ultrasonography, and CEUS (p < .0001). Quantitative analysis showed a higher enhancement peak, a shorter time to peak enhancement, a higher regional blood flow and regional blood volume in patients with high vascular density than in those with low vascular density. Cutoff values to distinguish between active and inactive disease were identified for peak enhancement (>40.5%), and regional blood flow (>54.8 ml/min). Conclusion: Quantitative analysis of CEUS data correlates with disease activity as determined by vascular density. Quantitative parameters of CEUS can be used to predict active disease with high sensitivity and

  13. Quantitative analysis of surface characteristics and morphology in Death Valley, California using AIRSAR data

    Science.gov (United States)

    Kierein-Young, K. S.; Kruse, F. A.; Lefkoff, A. B.

    1992-01-01

    The Jet Propulsion Laboratory Airborne Synthetic Aperture Radar (JPL-AIRSAR) is used to collect full polarimetric measurements at P-, L-, and C-bands. These data are analyzed using the radar analysis and visualization environment (RAVEN). The AIRSAR data are calibrated using in-scene corner reflectors to allow for quantitative analysis of the radar backscatter. RAVEN is used to extract surface characteristics. Inversion models are used to calculate quantitative surface roughness values and fractal dimensions. These values are used to generate synthetic surface plots that represent the small-scale surface structure of areas in Death Valley. These procedures are applied to a playa, smooth salt-pan, and alluvial fan surfaces in Death Valley. Field measurements of surface roughness are used to verify the accuracy.

  14. Theory of quantitative trend analysis and its application to the South African elections

    CSIR Research Space (South Africa)

    Greben, JM

    2006-02-28

    Full Text Available In this paper the author discusses a quantitative theory of trend analysis. Often trends are based on qualitative considerations and subjective assumptions. In the current approach the author makes use of extensive data bases to optimise the so...

  15. Quantitative trace element analysis of individual fly ash particles by means of X-ray microfluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vincze, L.; Somogyi, A.; Osan, J.; Vekemans, B.; Torok, S.; Janssens, K.; Adams, F. [Universitaire of Instelling Antwerp, Wilrijk (Belgium). Dept. of Chemistry

    2002-07-01

    A new quantification procedure was developed for the evaluation of X-ray microfluorescence (XRF) data sets obtained from individual particles, based on iterative Monte Carlo (MC) simulation. Combined with the high sensitivity of synchrotron radiation-induced XRF spectroscopy, the method was used to obtain quantitative information down to trace-level concentrations from micrometer-sized particulate matter. The detailed XRF simulation model was validated by comparison of calculated and experimental XRF spectra obtained for glass microsphere standards, resulting in uncertainties in the range of 3-10% for the calculated elemental sensitivities. The simulation model was applied for the quantitative analysis of X-ray tube and synchrotron radiation-induced scanning micro-XRF spectra of individual coal and wood fly ash particles originating from different Hungarian power plants. By measuring the same particles by both methods the major, minor, and trace element compositions of the particles were determined. The uncertainty of the MC based quantitative analysis scheme is estimated to be in the range of 5-30%.

  16. Stochastic resonance is applied to quantitative analysis for weak chromatographic signal of glyburide in plasma

    International Nuclear Information System (INIS)

    Zhang Wei; Xiang Bingren; Wu Yanwei; Shang Erxin

    2005-01-01

    Based on the theory of stochastic resonance, a new method carried on the quantitive analysis to weak chromatographic signal of glyburide in plasma, which was embedded in the noise background and the signal-to-noise ratio (SNR) of HPLC-UV is enhanced remarkably. This method enhances the quantification limit to 1 ng ml -1 , which is the same as HPLC-MS, and makes it possible to detect the weak signal accurately by HPLC-UV, which was not suitable before. The results showed good recovery and linear range from 1 to 50 ng ml -1 of glyburide in plasma and the method can be used for quantitative analysis of glyburide

  17. Dynamics of group knowledge production in facilitated modelling workshops

    DEFF Research Database (Denmark)

    Tavella, Elena; Franco, L. Alberto

    2015-01-01

    by which models are jointly developed with group members interacting face-to-face, with or without computer support. The models produced are used to inform negotiations about the nature of the issues faced by the group, and how to address them. While the facilitated modelling literature is impressive......, the workshop. Drawing on the knowledge-perspective of group communication, we conducted a micro-level analysis of a transcript of a facilitated modelling workshop held with the management team of an Alternative Food Network in the UK. Our analysis suggests that facilitated modelling interactions can take...

  18. Quantitative analysis of infantile ureteropelvic junction obstruction by diuretic renography

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Shigeru; Suzuki, Yutaka; Murakami, Takeshi; Yokoyama, Seishichi; Hirakawa, Hitoshi; Tajima, Tomoo; Makuuchi, Hiroyasu [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    2001-04-01

    Infantile hydronephrosis detected by ultrasonography poses a clinical dilemma on how to treat the condition. This article reports a retrospective study to evaluate infantile hydronephrosis due to suspected ureteropelvic junction (UPJ) obstruction by means of standardized diuretic renography and to speculate its usefulness for quantitative assessment and management of this condition. Between November 1992 and July 1999, 43 patients who had the disease detected in their fetal or infantile period were submitted to this study. Standardized diuretic renograms were obtained with {sup 99m}Tc-labeled diethylene-triaminepenta-acetate (Tc-99m-DTPA) or {sup 99m}Tc-labeled mercaptoacetyl triglycine (Tc-99m-MAG3) as radiopharmaceuticals. Drainage half-time clearance (T 1/2) of the activity at each region of interest set to encompass the entire kidney and the dilated pelvis was used as an index of quantitative analysis of UPJ obstruction. Initial T 1/2s of 32 kidneys with suspected UPJ obstruction were significantly longer than those of 37 without obstruction. T 1/2s of kidneys which had undergone pyeloplasty decreased promptly after surgery whereas those of units followed up without surgery decreased more sluggishly. These findings demonstrate that a standardized diuretic renographic analysis with T 1/2 can reliably assess infantile hydronephrosis with UPJ obstruction and be helpful in making a decision on surgical intervention. (author)

  19. Quantitative analysis of infantile ureteropelvic junction obstruction by diuretic renography

    International Nuclear Information System (INIS)

    Ueno, Shigeru; Suzuki, Yutaka; Murakami, Takeshi; Yokoyama, Seishichi; Hirakawa, Hitoshi; Tajima, Tomoo; Makuuchi, Hiroyasu

    2001-01-01

    Infantile hydronephrosis detected by ultrasonography poses a clinical dilemma on how to treat the condition. This article reports a retrospective study to evaluate infantile hydronephrosis due to suspected ureteropelvic junction (UPJ) obstruction by means of standardized diuretic renography and to speculate its usefulness for quantitative assessment and management of this condition. Between November 1992 and July 1999, 43 patients who had the disease detected in their fetal or infantile period were submitted to this study. Standardized diuretic renograms were obtained with 99m Tc-labeled diethylene-triaminepenta-acetate (Tc-99m-DTPA) or 99m Tc-labeled mercaptoacetyl triglycine (Tc-99m-MAG3) as radiopharmaceuticals. Drainage half-time clearance (T 1/2) of the activity at each region of interest set to encompass the entire kidney and the dilated pelvis was used as an index of quantitative analysis of UPJ obstruction. Initial T 1/2s of 32 kidneys with suspected UPJ obstruction were significantly longer than those of 37 without obstruction. T 1/2s of kidneys which had undergone pyeloplasty decreased promptly after surgery whereas those of units followed up without surgery decreased more sluggishly. These findings demonstrate that a standardized diuretic renographic analysis with T 1/2 can reliably assess infantile hydronephrosis with UPJ obstruction and be helpful in making a decision on surgical intervention. (author)

  20. Quantitative analysis of light elements in aerosol samples by PIGE

    International Nuclear Information System (INIS)

    Mateus, R.; Reis, M.A.; Jesus, A.P.; Ribeiro, J.P.

    2006-01-01

    Quantitative PIGE analysis of aerosol samples collected on nuclepore polycarbonate filters was performed by a method that avoids the use of comparative standards. Nuclear cross sections and calibration parameters established before in an extensive work on thick and intermediate samples were employed. For these samples, the excitation functions of nuclear reactions, induced by the incident protons on target's light elements, were used as input for a code that evaluates the gamma-ray yield integrating along the depth of the sample. In the present work we apply the same code to validate the use of an effective energy for thin sample analysis. Results pertaining to boron, fluorine and sodium concentrations are presented. In order to establish a correlation with sodium values, PIXE results related to chlorine are also presented, giving support to the reliability of this PIGE method for thin film analysis

  1. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker.

    Science.gov (United States)

    Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing

    2016-05-08

    Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.

  2. A Data Analysis Pipeline Accounting for Artifacts in Tox21 Quantitative High-Throughput Screening Assays.

    Science.gov (United States)

    Hsieh, Jui-Hua; Sedykh, Alexander; Huang, Ruili; Xia, Menghang; Tice, Raymond R

    2015-08-01

    A main goal of the U.S. Tox21 program is to profile a 10K-compound library for activity against a panel of stress-related and nuclear receptor signaling pathway assays using a quantitative high-throughput screening (qHTS) approach. However, assay artifacts, including nonreproducible signals and assay interference (e.g., autofluorescence), complicate compound activity interpretation. To address these issues, we have developed a data analysis pipeline that includes an updated signal noise-filtering/curation protocol and an assay interference flagging system. To better characterize various types of signals, we adopted a weighted version of the area under the curve (wAUC) to quantify the amount of activity across the tested concentration range in combination with the assay-dependent point-of-departure (POD) concentration. Based on the 32 Tox21 qHTS assays analyzed, we demonstrate that signal profiling using wAUC affords the best reproducibility (Pearson's r = 0.91) in comparison with the POD (0.82) only or the AC(50) (i.e., half-maximal activity concentration, 0.81). Among the activity artifacts characterized, cytotoxicity is the major confounding factor; on average, about 8% of Tox21 compounds are affected, whereas autofluorescence affects less than 0.5%. To facilitate data evaluation, we implemented two graphical user interface applications, allowing users to rapidly evaluate the in vitro activity of Tox21 compounds. © 2015 Society for Laboratory Automation and Screening.

  3. Implementation of fall prevention in residential care facilities: A systematic review of barriers and facilitators.

    Science.gov (United States)

    Vlaeyen, Ellen; Stas, Joke; Leysens, Greet; Van der Elst, Elisa; Janssens, Elise; Dejaeger, Eddy; Dobbels, Fabienne; Milisen, Koen

    2017-05-01

    To identify the barriers and facilitators for fall prevention implementation in residential care facilities. Systematic review. Review registration number on PROSPERO: CRD42013004655. Two independent reviewers systematically searched five databases (i.e. MEDLINE, EMBASE, CINAHL, PsycINFO, and Web of Science) and the reference lists of relevant articles. This systematic review was conducted in line with the Center for Reviews and Dissemination Handbook and reported according to the PRISMA guideline. Only original research focusing on determinants of fall prevention implementation in residential care facilities was included. We used the Mixed Method Appraisal Tool for quality appraisal. Thematic analysis was performed for qualitative data; quantitative data were analyzed descriptively. To synthesize the results, we used the framework of Grol and colleagues that describes six healthcare levels wherein implementation barriers and facilitators can be identified. We found eight relevant studies, identifying 44 determinants that influence implementation. Of these, 17 were facilitators and 27 were barriers. Results indicated that the social and organizational levels have the greatest number of influencing factors (9 and 14, respectively), whereas resident and economical/political levels have the least (3 and 4, respectively). The most cited facilitators were good communication and facility equipment availability, while staff feeling overwhelmed, helpless, frustrated and concerned about their ability to control fall management, staffing issues, limited knowledge and skills (i.e., general clinical skill deficiencies, poor fall management skills or lack of computer skills); and poor communication were the most cited barriers. Successful implementation of fall prevention depends on many factors across different healthcare levels. The focus of implementation interventions, however, should be on modifiable barriers and facilitators such as communication, knowledge, and skills

  4. Analysis of high accuracy, quantitative proteomics data in the MaxQB database.

    Science.gov (United States)

    Schaab, Christoph; Geiger, Tamar; Stoehr, Gabriele; Cox, Juergen; Mann, Matthias

    2012-03-01

    MS-based proteomics generates rapidly increasing amounts of precise and quantitative information. Analysis of individual proteomic experiments has made great strides, but the crucial ability to compare and store information across different proteome measurements still presents many challenges. For example, it has been difficult to avoid contamination of databases with low quality peptide identifications, to control for the inflation in false positive identifications when combining data sets, and to integrate quantitative data. Although, for example, the contamination with low quality identifications has been addressed by joint analysis of deposited raw data in some public repositories, we reasoned that there should be a role for a database specifically designed for high resolution and quantitative data. Here we describe a novel database termed MaxQB that stores and displays collections of large proteomics projects and allows joint analysis and comparison. We demonstrate the analysis tools of MaxQB using proteome data of 11 different human cell lines and 28 mouse tissues. The database-wide false discovery rate is controlled by adjusting the project specific cutoff scores for the combined data sets. The 11 cell line proteomes together identify proteins expressed from more than half of all human genes. For each protein of interest, expression levels estimated by label-free quantification can be visualized across the cell lines. Similarly, the expression rank order and estimated amount of each protein within each proteome are plotted. We used MaxQB to calculate the signal reproducibility of the detected peptides for the same proteins across different proteomes. Spearman rank correlation between peptide intensity and detection probability of identified proteins was greater than 0.8 for 64% of the proteome, whereas a minority of proteins have negative correlation. This information can be used to pinpoint false protein identifications, independently of peptide database

  5. Spectral Quantitative Analysis Model with Combining Wavelength Selection and Topology Structure Optimization

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2016-01-01

    Full Text Available Spectroscopy is an efficient and widely used quantitative analysis method. In this paper, a spectral quantitative analysis model with combining wavelength selection and topology structure optimization is proposed. For the proposed method, backpropagation neural network is adopted for building the component prediction model, and the simultaneousness optimization of the wavelength selection and the topology structure of neural network is realized by nonlinear adaptive evolutionary programming (NAEP. The hybrid chromosome in binary scheme of NAEP has three parts. The first part represents the topology structure of neural network, the second part represents the selection of wavelengths in the spectral data, and the third part represents the parameters of mutation of NAEP. Two real flue gas datasets are used in the experiments. In order to present the effectiveness of the methods, the partial least squares with full spectrum, the partial least squares combined with genetic algorithm, the uninformative variable elimination method, the backpropagation neural network with full spectrum, the backpropagation neural network combined with genetic algorithm, and the proposed method are performed for building the component prediction model. Experimental results verify that the proposed method has the ability to predict more accurately and robustly as a practical spectral analysis tool.

  6. Meta-analysis is not an exact science: Call for guidance on quantitative synthesis decisions.

    Science.gov (United States)

    Haddaway, Neal R; Rytwinski, Trina

    2018-05-01

    Meta-analysis is becoming increasingly popular in the field of ecology and environmental management. It increases the effective power of analyses relative to single studies, and allows researchers to investigate effect modifiers and sources of heterogeneity that could not be easily examined within single studies. Many systematic reviewers will set out to conduct a meta-analysis as part of their synthesis, but meta-analysis requires a niche set of skills that are not widely held by the environmental research community. Each step in the process of carrying out a meta-analysis requires decisions that have both scientific and statistical implications. Reviewers are likely to be faced with a plethora of decisions over which effect size to choose, how to calculate variances, and how to build statistical models. Some of these decisions may be simple based on appropriateness of the options. At other times, reviewers must choose between equally valid approaches given the information available to them. This presents a significant problem when reviewers are attempting to conduct a reliable synthesis, such as a systematic review, where subjectivity is minimised and all decisions are documented and justified transparently. We propose three urgent, necessary developments within the evidence synthesis community. Firstly, we call on quantitative synthesis experts to improve guidance on how to prepare data for quantitative synthesis, providing explicit detail to support systematic reviewers. Secondly, we call on journal editors and evidence synthesis coordinating bodies (e.g. CEE) to ensure that quantitative synthesis methods are adequately reported in a transparent and repeatable manner in published systematic reviews. Finally, where faced with two or more broadly equally valid alternative methods or actions, reviewers should conduct multiple analyses, presenting all options, and discussing the implications of the different analytical approaches. We believe it is vital to tackle

  7. Quantitative image analysis for investigating cell-matrix interactions

    Science.gov (United States)

    Burkel, Brian; Notbohm, Jacob

    2017-07-01

    The extracellular matrix provides both chemical and physical cues that control cellular processes such as migration, division, differentiation, and cancer progression. Cells can mechanically alter the matrix by applying forces that result in matrix displacements, which in turn may localize to form dense bands along which cells may migrate. To quantify the displacements, we use confocal microscopy and fluorescent labeling to acquire high-contrast images of the fibrous material. Using a technique for quantitative image analysis called digital volume correlation, we then compute the matrix displacements. Our experimental technology offers a means to quantify matrix mechanics and cell-matrix interactions. We are now using these experimental tools to modulate mechanical properties of the matrix to study cell contraction and migration.

  8. Quantitative spectral and orientational analysis in surface sum frequency generation vibrational spectroscopy (SFG-VS)

    Science.gov (United States)

    Wang, Hong-Fei; Gan, Wei; Lu, Rong; Rao, Yi; Wu, Bao-Hua

    Sum frequency generation vibrational spectroscopy (SFG-VS) has been proven to be a uniquely effective spectroscopic technique in the investigation of molecular structure and conformations, as well as the dynamics of molecular interfaces. However, the ability to apply SFG-VS to complex molecular interfaces has been limited by the ability to abstract quantitative information from SFG-VS experiments. In this review, we try to make assessments of the limitations, issues and techniques as well as methodologies in quantitative orientational and spectral analysis with SFG-VS. Based on these assessments, we also try to summarize recent developments in methodologies on quantitative orientational and spectral analysis in SFG-VS, and their applications to detailed analysis of SFG-VS data of various vapour/neat liquid interfaces. A rigorous formulation of the polarization null angle (PNA) method is given for accurate determination of the orientational parameter D = /, and comparison between the PNA method with the commonly used polarization intensity ratio (PIR) method is discussed. The polarization and incident angle dependencies of the SFG-VS intensity are also reviewed, in the light of how experimental arrangements can be optimized to effectively abstract crucial information from the SFG-VS experiments. The values and models of the local field factors in the molecular layers are discussed. In order to examine the validity and limitations of the bond polarizability derivative model, the general expressions for molecular hyperpolarizability tensors and their expression with the bond polarizability derivative model for C3v, C2v and C∞v molecular groups are given in the two appendixes. We show that the bond polarizability derivative model can quantitatively describe many aspects of the intensities observed in the SFG-VS spectrum of the vapour/neat liquid interfaces in different polarizations. Using the polarization analysis in SFG-VS, polarization selection rules or

  9. Balancing the Quantitative and Qualitative Aspects of Social Network Analysis to Study Complex Social Systems

    OpenAIRE

    Schipper, Danny; Spekkink, Wouter

    2015-01-01

    Social Network Analysis (SNA) can be used to investigate complex social systems. SNA is typically applied as a quantitative method, which has important limitations. First, quantitative methods are capable of capturing the form of relationships (e.g. strength and frequency), but they are less suitable for capturing the content of relationships (e.g. interests and motivations). Second, while complex social systems are highly dynamic, the representations that SNA creates of such systems are ofte...

  10. Quantitative comparison of analysis methods for spectroscopic optical coherence tomography: reply to comment

    NARCIS (Netherlands)

    Bosschaart, Nienke; van Leeuwen, Ton; Aalders, Maurice C.G.; Faber, Dirk

    2014-01-01

    We reply to the comment by Kraszewski et al on “Quantitative comparison of analysis methods for spectroscopic optical coherence tomography.” We present additional simulations evaluating the proposed window function. We conclude that our simulations show good qualitative agreement with the results of

  11. A Quantitative Analysis of the Extrinsic and Intrinsic Turnover Factors of Relational Database Support Professionals

    Science.gov (United States)

    Takusi, Gabriel Samuto

    2010-01-01

    This quantitative analysis explored the intrinsic and extrinsic turnover factors of relational database support specialists. Two hundred and nine relational database support specialists were surveyed for this research. The research was conducted based on Hackman and Oldham's (1980) Job Diagnostic Survey. Regression analysis and a univariate ANOVA…

  12. A Quantitative Analysis of Pulsed Signals Emitted by Wild Bottlenose Dolphins.

    Directory of Open Access Journals (Sweden)

    Ana Rita Luís

    Full Text Available Common bottlenose dolphins (Tursiops truncatus, produce a wide variety of vocal emissions for communication and echolocation, of which the pulsed repertoire has been the most difficult to categorize. Packets of high repetition, broadband pulses are still largely reported under a general designation of burst-pulses, and traditional attempts to classify these emissions rely mainly in their aural characteristics and in graphical aspects of spectrograms. Here, we present a quantitative analysis of pulsed signals emitted by wild bottlenose dolphins, in the Sado estuary, Portugal (2011-2014, and test the reliability of a traditional classification approach. Acoustic parameters (minimum frequency, maximum frequency, peak frequency, duration, repetition rate and inter-click-interval were extracted from 930 pulsed signals, previously categorized using a traditional approach. Discriminant function analysis revealed a high reliability of the traditional classification approach (93.5% of pulsed signals were consistently assigned to their aurally based categories. According to the discriminant function analysis (Wilk's Λ = 0.11, F3, 2.41 = 282.75, P < 0.001, repetition rate is the feature that best enables the discrimination of different pulsed signals (structure coefficient = 0.98. Classification using hierarchical cluster analysis led to a similar categorization pattern: two main signal types with distinct magnitudes of repetition rate were clustered into five groups. The pulsed signals, here described, present significant differences in their time-frequency features, especially repetition rate (P < 0.001, inter-click-interval (P < 0.001 and duration (P < 0.001. We document the occurrence of a distinct signal type-short burst-pulses, and highlight the existence of a diverse repertoire of pulsed vocalizations emitted in graded sequences. The use of quantitative analysis of pulsed signals is essential to improve classifications and to better assess the

  13. Quantitative analysis of flow processes in a sand using synchrotron-based X-ray microtomography

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Hopmans, J.W.; Rivers, M.L.

    2005-01-01

    been of a mostly qualitative nature and no experiments have been presented in the existing literature where a truly quantitative approach to investigating the multiphase flow process has been taken, including a thorough image-processing scheme. The tomographic images presented here show, both......Pore-scale multiphase flow experiments were developed to nondestructively visualize water flow in a sample of porous material using X-ray microtomography. The samples were exposed to similar boundary conditions as in a previous investigation, which examined the effect of initial flow rate...... by qualitative comparison and quantitative analysis in the form of a nearest neighbor analysis, that the dynamic effects seen in previous experiments are likely due to the fast and preferential drainage of large pores in the sample. Once a continuous drained path has been established through the sample, further...

  14. Quantitative analysis of Si1-xGex alloy films by SIMS and XPS depth profiling using a reference material

    Science.gov (United States)

    Oh, Won Jin; Jang, Jong Shik; Lee, Youn Seoung; Kim, Ansoon; Kim, Kyung Joong

    2018-02-01

    Quantitative analysis methods of multi-element alloy films were compared. The atomic fractions of Si1-xGex alloy films were measured by depth profiling analysis with secondary ion mass spectrometry (SIMS) and X-ray Photoelectron Spectroscopy (XPS). Intensity-to-composition conversion factor (ICF) was used as a mean to convert the intensities to compositions instead of the relative sensitivity factors. The ICFs were determined from a reference Si1-xGex alloy film by the conventional method, average intensity (AI) method and total number counting (TNC) method. In the case of SIMS, although the atomic fractions measured by oxygen ion beams were not quantitative due to severe matrix effect, the results by cesium ion beam were very quantitative. The quantitative analysis results by SIMS using MCs2+ ions are comparable to the results by XPS. In the case of XPS, the measurement uncertainty was highly improved by the AI method and TNC method.

  15. Pseudo-absolute quantitative analysis using gas chromatography – Vacuum ultraviolet spectroscopy – A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Ling [Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX (United States); Smuts, Jonathan; Walsh, Phillip [VUV Analytics, Inc., Cedar Park, TX (United States); Qiu, Changling [Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX (United States); McNair, Harold M. [Department of Chemistry, Virginia Tech, Blacksburg, VA (United States); Schug, Kevin A., E-mail: kschug@uta.edu [Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX (United States)

    2017-02-08

    The vacuum ultraviolet detector (VUV) is a new non-destructive mass sensitive detector for gas chromatography that continuously and rapidly collects full wavelength range absorption between 120 and 240 nm. In addition to conventional methods of quantification (internal and external standard), gas chromatography - vacuum ultraviolet spectroscopy has the potential for pseudo-absolute quantification of analytes based on pre-recorded cross sections (well-defined absorptivity across the 120–240 nm wavelength range recorded by the detector) without the need for traditional calibration. The pseudo-absolute method was used in this research to experimentally evaluate the sources of sample loss and gain associated with sample introduction into a typical gas chromatograph. Standard samples of benzene and natural gas were used to assess precision and accuracy for the analysis of liquid and gaseous samples, respectively, based on the amount of analyte loaded on-column. Results indicate that injection volume, split ratio, and sampling times for splitless analysis can all contribute to inaccurate, yet precise sample introduction. For instance, an autosampler can very reproducibly inject a designated volume, but there are significant systematic errors (here, a consistently larger volume than that designated) in the actual volume introduced. The pseudo-absolute quantification capability of the vacuum ultraviolet detector provides a new means for carrying out system performance checks and potentially for solving challenging quantitative analytical problems. For practical purposes, an internal standardized approach to normalize systematic errors can be used to perform quantitative analysis with the pseudo-absolute method. - Highlights: • Gas chromatography diagnostics and quantification using VUV detector. • Absorption cross-sections for molecules enable pseudo-absolute quantitation. • Injection diagnostics reveal systematic errors in hardware settings. • Internal

  16. Pseudo-absolute quantitative analysis using gas chromatography – Vacuum ultraviolet spectroscopy – A tutorial

    International Nuclear Information System (INIS)

    Bai, Ling; Smuts, Jonathan; Walsh, Phillip; Qiu, Changling; McNair, Harold M.; Schug, Kevin A.

    2017-01-01

    The vacuum ultraviolet detector (VUV) is a new non-destructive mass sensitive detector for gas chromatography that continuously and rapidly collects full wavelength range absorption between 120 and 240 nm. In addition to conventional methods of quantification (internal and external standard), gas chromatography - vacuum ultraviolet spectroscopy has the potential for pseudo-absolute quantification of analytes based on pre-recorded cross sections (well-defined absorptivity across the 120–240 nm wavelength range recorded by the detector) without the need for traditional calibration. The pseudo-absolute method was used in this research to experimentally evaluate the sources of sample loss and gain associated with sample introduction into a typical gas chromatograph. Standard samples of benzene and natural gas were used to assess precision and accuracy for the analysis of liquid and gaseous samples, respectively, based on the amount of analyte loaded on-column. Results indicate that injection volume, split ratio, and sampling times for splitless analysis can all contribute to inaccurate, yet precise sample introduction. For instance, an autosampler can very reproducibly inject a designated volume, but there are significant systematic errors (here, a consistently larger volume than that designated) in the actual volume introduced. The pseudo-absolute quantification capability of the vacuum ultraviolet detector provides a new means for carrying out system performance checks and potentially for solving challenging quantitative analytical problems. For practical purposes, an internal standardized approach to normalize systematic errors can be used to perform quantitative analysis with the pseudo-absolute method. - Highlights: • Gas chromatography diagnostics and quantification using VUV detector. • Absorption cross-sections for molecules enable pseudo-absolute quantitation. • Injection diagnostics reveal systematic errors in hardware settings. • Internal

  17. New approaches for the analysis of confluent cell layers with quantitative phase digital holographic microscopy

    Science.gov (United States)

    Pohl, L.; Kaiser, M.; Ketelhut, S.; Pereira, S.; Goycoolea, F.; Kemper, Björn

    2016-03-01

    Digital holographic microscopy (DHM) enables high resolution non-destructive inspection of technical surfaces and minimally-invasive label-free live cell imaging. However, the analysis of confluent cell layers represents a challenge as quantitative DHM phase images in this case do not provide sufficient information for image segmentation, determination of the cellular dry mass or calculation of the cell thickness. We present novel strategies for the analysis of confluent cell layers with quantitative DHM phase contrast utilizing a histogram based-evaluation procedure. The applicability of our approach is illustrated by quantification of drug induced cell morphology changes and it is shown that the method is capable to quantify reliable global morphology changes of confluent cell layers.

  18. Quantitative and qualitative analysis of the expert and non-expert opinion in fire risk in buildings

    International Nuclear Information System (INIS)

    Hanea, D.M.; Jagtman, H.M.; Alphen, L.L.M.M. van; Ale, B.J.M.

    2010-01-01

    Expert judgment procedure is a method very often used in the area of risk assessments of complex systems or processes to fill in quantitative data. Although it has been proved to be a very reliable source of information when no other data are available, the choice of experts is always questioned. When the available data are limited, the seed questions cover only partially the domains of expertise, which may cause problems. Expertise is assessed not covering the full object of study but only those topics for which seed questions can be formulated. The commonly used quantitative analysis of an expert judgment exercise is combined with a qualitative analysis. The latter adds more insights to the relation between the assessor's field and statistical knowledge and their performance in an expert judgment. In addition the qualitative analysis identifies different types of seed questions. Three groups of assessors with different levels of statistical and domain knowledge are studied. The quantitative analysis shows no differences between field experts and non-experts and no differences between having advanced statistical knowledge or not. The qualitative analysis supports these findings. In addition it is found that especially technical questions are answered with larger intervals. Precaution is required when using seed questions for which the real value can be calculated, which was the case for one of the seed questions.

  19. Quantitative analysis of drug distribution by ambient mass spectrometry imaging method with signal extinction normalization strategy and inkjet-printing technology.

    Science.gov (United States)

    Luo, Zhigang; He, Jingjing; He, Jiuming; Huang, Lan; Song, Xiaowei; Li, Xin; Abliz, Zeper

    2018-03-01

    Quantitative mass spectrometry imaging (MSI) is a robust approach that provides both quantitative and spatial information for drug candidates' research. However, because of complicated signal suppression and interference, acquiring accurate quantitative information from MSI data remains a challenge, especially for whole-body tissue sample. Ambient MSI techniques using spray-based ionization appear to be ideal for pharmaceutical quantitative MSI analysis. However, it is more challenging, as it involves almost no sample preparation and is more susceptible to ion suppression/enhancement. Herein, based on our developed air flow-assisted desorption electrospray ionization (AFADESI)-MSI technology, an ambient quantitative MSI method was introduced by integrating inkjet-printing technology with normalization of the signal extinction coefficient (SEC) using the target compound itself. The method utilized a single calibration curve to quantify multiple tissue types. Basic blue 7 and an antitumor drug candidate (S-(+)-deoxytylophorinidine, CAT) were chosen to initially validate the feasibility and reliability of the quantitative MSI method. Rat tissue sections (heart, kidney, and brain) administered with CAT was then analyzed. The quantitative MSI analysis results were cross-validated by LC-MS/MS analysis data of the same tissues. The consistency suggests that the approach is able to fast obtain the quantitative MSI data without introducing interference into the in-situ environment of the tissue sample, and is potential to provide a high-throughput, economical and reliable approach for drug discovery and development. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Quantitative model analysis with diverse biological data: applications in developmental pattern formation.

    Science.gov (United States)

    Pargett, Michael; Umulis, David M

    2013-07-15

    Mathematical modeling of transcription factor and signaling networks is widely used to understand if and how a mechanism works, and to infer regulatory interactions that produce a model consistent with the observed data. Both of these approaches to modeling are informed by experimental data, however, much of the data available or even acquirable are not quantitative. Data that is not strictly quantitative cannot be used by classical, quantitative, model-based analyses that measure a difference between the measured observation and the model prediction for that observation. To bridge the model-to-data gap, a variety of techniques have been developed to measure model "fitness" and provide numerical values that can subsequently be used in model optimization or model inference studies. Here, we discuss a selection of traditional and novel techniques to transform data of varied quality and enable quantitative comparison with mathematical models. This review is intended to both inform the use of these model analysis methods, focused on parameter estimation, and to help guide the choice of method to use for a given study based on the type of data available. Applying techniques such as normalization or optimal scaling may significantly improve the utility of current biological data in model-based study and allow greater integration between disparate types of data. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Criminal Justice Systems in Europe. A cross-national quantitative analysis

    OpenAIRE

    Becerra-Muñoz, Jose; García-España, Elisa; Aguilar Conde, Araceli

    2013-01-01

    In the last years, the Crime Observatory of the University of Malaga has analysed police records on criminal activity, has also carried out several crime victims surveys in Spain and has worked on a detailed analysis of the prison system and its connection to the prison policy. This year´s report focuses on the Criminal Justice System, one of the big official data providers, to gather, organize and interpret a great deal of quantitative data from 2000 to 2011. Such longitudinal scrutiny of...

  2. Use of deuteron-induced nuclear reactions for quantitative surface analysis

    International Nuclear Information System (INIS)

    Simpson, J.C.B.; Earwaker, L.G.

    1986-01-01

    A summary of the basic features of nuclear reaction analysis is given; particular emphasis is placed on quantitative light element determination using (d,p) and (d,α) reactions. The experimental apparatus is also described, with reference to the 3MV Dynamitron accelerator at the University of Birmingham Radiation Centre. Finally, a set of standard (d, p) spectra for the elements Z=3 to Z=17, using 2 MeV incident deuterons, is included together with examples of the more useful of the (d,α) spectra. (orig.)

  3. Improved noninvasive assessment of coronary artery disease by quantitative analysis of regional stress myocardial distribution and washout of thallium-201

    International Nuclear Information System (INIS)

    Maddahi, J.; Garcia, E.V.; Berman, D.S.; Waxman, A.; Swan, H.J.C.; Forrester, J.

    1981-01-01

    Visual interpretation of stress-redistribution thallium-201 ( 201 Tl) scintigrams is subject to observer variability and is suboptimal for evaluation of extent of coronary artery disease (CAD). An objective, computerized technique has been developed that quantitatively expresses the relative space-time myocardial distribution of 201 Tl. Multiple-view, maximum-count circumferential profiles for stress myocardial distribution of 201 Tl and segmental percent washout were analyzed in a pilot group of 31 normal subjects and 20 patients with CAD to develop quantitative criteria for abnormality. Subsequently, quantitative analysis was applied prospectively to a group of 22 normal subjects and 45 CAD patients and compared with visual interpretation of scintigrams for detection and evaluation of CAD. The sensitivity and specificity of the quantitative technique (93% and 91%, respectively) were not significantly different from those of the visual method (91% and 86%). The quantitative analysis significantly (p 201 Tl imaging over the visual method in the left anterior descending artery (from 56% to 80%), left circumflex artery (from 34% to 63%) and right coronary artery (from 65% to 94%) without significant loss of specificity. Using quantitative analysis, sensitivity for detection of deseased vessels did not diminish as the number of vessels involved increased, as it did with visual interpretations. In patients with one-vessel disease, 86% of the lesions were detected by both techniques; however, in patients with three-vessel disease, quantitative analysis detected 83% of the lesions, while the sensitivity was only 53% for the visual method. Seventy percent of the coronary arteries with moderate

  4. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    Science.gov (United States)

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (Panalysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  5. Direct comparison of low- and mid-frequency Raman spectroscopy for quantitative solid-state pharmaceutical analysis.

    Science.gov (United States)

    Lipiäinen, Tiina; Fraser-Miller, Sara J; Gordon, Keith C; Strachan, Clare J

    2018-02-05

    This study considers the potential of low-frequency (terahertz) Raman spectroscopy in the quantitative analysis of ternary mixtures of solid-state forms. Direct comparison between low-frequency and mid-frequency spectral regions for quantitative analysis of crystal form mixtures, without confounding sampling and instrumental variations, is reported for the first time. Piroxicam was used as a model drug, and the low-frequency spectra of piroxicam forms β, α2 and monohydrate are presented for the first time. These forms show clear spectral differences in both the low- and mid-frequency regions. Both spectral regions provided quantitative models suitable for predicting the mixture compositions using partial least squares regression (PLSR), but the low-frequency data gave better models, based on lower errors of prediction (2.7, 3.1 and 3.2% root-mean-square errors of prediction [RMSEP] values for the β, α2 and monohydrate forms, respectively) than the mid-frequency data (6.3, 5.4 and 4.8%, for the β, α2 and monohydrate forms, respectively). The better performance of low-frequency Raman analysis was attributed to larger spectral differences between the solid-state forms, combined with a higher signal-to-noise ratio. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Watershed Planning within a Quantitative Scenario Analysis Framework.

    Science.gov (United States)

    Merriam, Eric R; Petty, J Todd; Strager, Michael P

    2016-07-24

    There is a critical need for tools and methodologies capable of managing aquatic systems within heavily impacted watersheds. Current efforts often fall short as a result of an inability to quantify and predict complex cumulative effects of current and future land use scenarios at relevant spatial scales. The goal of this manuscript is to provide methods for conducting a targeted watershed assessment that enables resource managers to produce landscape-based cumulative effects models for use within a scenario analysis management framework. Sites are first selected for inclusion within the watershed assessment by identifying sites that fall along independent gradients and combinations of known stressors. Field and laboratory techniques are then used to obtain data on the physical, chemical, and biological effects of multiple land use activities. Multiple linear regression analysis is then used to produce landscape-based cumulative effects models for predicting aquatic conditions. Lastly, methods for incorporating cumulative effects models within a scenario analysis framework for guiding management and regulatory decisions (e.g., permitting and mitigation) within actively developing watersheds are discussed and demonstrated for 2 sub-watersheds within the mountaintop mining region of central Appalachia. The watershed assessment and management approach provided herein enables resource managers to facilitate economic and development activity while protecting aquatic resources and producing opportunity for net ecological benefits through targeted remediation.

  7. Fusing Quantitative Requirements Analysis with Model-based Systems Engineering

    Science.gov (United States)

    Cornford, Steven L.; Feather, Martin S.; Heron, Vance A.; Jenkins, J. Steven

    2006-01-01

    A vision is presented for fusing quantitative requirements analysis with model-based systems engineering. This vision draws upon and combines emergent themes in the engineering milieu. "Requirements engineering" provides means to explicitly represent requirements (both functional and non-functional) as constraints and preferences on acceptable solutions, and emphasizes early-lifecycle review, analysis and verification of design and development plans. "Design by shopping" emphasizes revealing the space of options available from which to choose (without presuming that all selection criteria have previously been elicited), and provides means to make understandable the range of choices and their ramifications. "Model-based engineering" emphasizes the goal of utilizing a formal representation of all aspects of system design, from development through operations, and provides powerful tool suites that support the practical application of these principles. A first step prototype towards this vision is described, embodying the key capabilities. Illustrations, implications, further challenges and opportunities are outlined.

  8. Quantitative proteomic analysis of human lung tumor xenografts treated with the ectopic ATP synthase inhibitor citreoviridin.

    Directory of Open Access Journals (Sweden)

    Yi-Hsuan Wu

    Full Text Available ATP synthase is present on the plasma membrane of several types of cancer cells. Citreoviridin, an ATP synthase inhibitor, selectively suppresses the proliferation and growth of lung cancer without affecting normal cells. However, the global effects of targeting ectopic ATP synthase in vivo have not been well defined. In this study, we performed quantitative proteomic analysis using isobaric tags for relative and absolute quantitation (iTRAQ and provided a comprehensive insight into the complicated regulation by citreoviridin in a lung cancer xenograft model. With high reproducibility of the quantitation, we obtained quantitative proteomic profiling with 2,659 proteins identified. Bioinformatics analysis of the 141 differentially expressed proteins selected by their relative abundance revealed that citreoviridin induces alterations in the expression of glucose metabolism-related enzymes in lung cancer. The up-regulation of enzymes involved in gluconeogenesis and storage of glucose indicated that citreoviridin may reduce the glycolytic intermediates for macromolecule synthesis and inhibit cell proliferation. Using comprehensive proteomics, the results identify metabolic aspects that help explain the antitumorigenic effect of citreoviridin in lung cancer, which may lead to a better understanding of the links between metabolism and tumorigenesis in cancer therapy.

  9. PANDA-view: An easy-to-use tool for statistical analysis and visualization of quantitative proteomics data.

    Science.gov (United States)

    Chang, Cheng; Xu, Kaikun; Guo, Chaoping; Wang, Jinxia; Yan, Qi; Zhang, Jian; He, Fuchu; Zhu, Yunping

    2018-05-22

    Compared with the numerous software tools developed for identification and quantification of -omics data, there remains a lack of suitable tools for both downstream analysis and data visualization. To help researchers better understand the biological meanings in their -omics data, we present an easy-to-use tool, named PANDA-view, for both statistical analysis and visualization of quantitative proteomics data and other -omics data. PANDA-view contains various kinds of analysis methods such as normalization, missing value imputation, statistical tests, clustering and principal component analysis, as well as the most commonly-used data visualization methods including an interactive volcano plot. Additionally, it provides user-friendly interfaces for protein-peptide-spectrum representation of the quantitative proteomics data. PANDA-view is freely available at https://sourceforge.net/projects/panda-view/. 1987ccpacer@163.com and zhuyunping@gmail.com. Supplementary data are available at Bioinformatics online.

  10. Functional linear models for association analysis of quantitative traits.

    Science.gov (United States)

    Fan, Ruzong; Wang, Yifan; Mills, James L; Wilson, Alexander F; Bailey-Wilson, Joan E; Xiong, Momiao

    2013-11-01

    Functional linear models are developed in this paper for testing associations between quantitative traits and genetic variants, which can be rare variants or common variants or the combination of the two. By treating multiple genetic variants of an individual in a human population as a realization of a stochastic process, the genome of an individual in a chromosome region is a continuum of sequence data rather than discrete observations. The genome of an individual is viewed as a stochastic function that contains both linkage and linkage disequilibrium (LD) information of the genetic markers. By using techniques of functional data analysis, both fixed and mixed effect functional linear models are built to test the association between quantitative traits and genetic variants adjusting for covariates. After extensive simulation analysis, it is shown that the F-distributed tests of the proposed fixed effect functional linear models have higher power than that of sequence kernel association test (SKAT) and its optimal unified test (SKAT-O) for three scenarios in most cases: (1) the causal variants are all rare, (2) the causal variants are both rare and common, and (3) the causal variants are common. The superior performance of the fixed effect functional linear models is most likely due to its optimal utilization of both genetic linkage and LD information of multiple genetic variants in a genome and similarity among different individuals, while SKAT and SKAT-O only model the similarities and pairwise LD but do not model linkage and higher order LD information sufficiently. In addition, the proposed fixed effect models generate accurate type I error rates in simulation studies. We also show that the functional kernel score tests of the proposed mixed effect functional linear models are preferable in candidate gene analysis and small sample problems. The methods are applied to analyze three biochemical traits in data from the Trinity Students Study. © 2013 WILEY

  11. Customized Body Mapping to Facilitate the Ergonomic Design of Sportswear.

    Science.gov (United States)

    Cao, Mingliang; Li, Yi; Guo, Yueping; Yao, Lei; Pan, Zhigeng

    2016-01-01

    A successful high-performance sportswear design that considers human factors should result in a significant increase in thermal comfort and reduce energy loss. The authors describe a body-mapping approach that facilitates the effective ergonomic design of sportswear. Their general framework can be customized based on the functional requirements of various sports and sportswear, the desired combination and selection of mapping areas for the human body, and customized quantitative data distribution of target physiological indicators.

  12. Particle induced X-ray emission for quantitative trace-element analysis using the Eindhoven cyclotron

    International Nuclear Information System (INIS)

    Kivits, H.

    1980-01-01

    Development of a multi-elemental trace analysis technique using PIXE (Particle Induced X-ray Emission), was started almost five years ago at the Eindhoven University of Technology, in the Cyclotron Applications Group of the Physics Department. The aim of the work presented is to improve the quantitative aspects of trace-element analysis with PIXE, as well as versatility, speed and simplicity. (Auth.)

  13. NiftyPET: a High-throughput Software Platform for High Quantitative Accuracy and Precision PET Imaging and Analysis.

    Science.gov (United States)

    Markiewicz, Pawel J; Ehrhardt, Matthias J; Erlandsson, Kjell; Noonan, Philip J; Barnes, Anna; Schott, Jonathan M; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Ourselin, Sebastien

    2018-01-01

    We present a standalone, scalable and high-throughput software platform for PET image reconstruction and analysis. We focus on high fidelity modelling of the acquisition processes to provide high accuracy and precision quantitative imaging, especially for large axial field of view scanners. All the core routines are implemented using parallel computing available from within the Python package NiftyPET, enabling easy access, manipulation and visualisation of data at any processing stage. The pipeline of the platform starts from MR and raw PET input data and is divided into the following processing stages: (1) list-mode data processing; (2) accurate attenuation coefficient map generation; (3) detector normalisation; (4) exact forward and back projection between sinogram and image space; (5) estimation of reduced-variance random events; (6) high accuracy fully 3D estimation of scatter events; (7) voxel-based partial volume correction; (8) region- and voxel-level image analysis. We demonstrate the advantages of this platform using an amyloid brain scan where all the processing is executed from a single and uniform computational environment in Python. The high accuracy acquisition modelling is achieved through span-1 (no axial compression) ray tracing for true, random and scatter events. Furthermore, the platform offers uncertainty estimation of any image derived statistic to facilitate robust tracking of subtle physiological changes in longitudinal studies. The platform also supports the development of new reconstruction and analysis algorithms through restricting the axial field of view to any set of rings covering a region of interest and thus performing fully 3D reconstruction and corrections using real data significantly faster. All the software is available as open source with the accompanying wiki-page and test data.

  14. Advantages of a Dynamic RGGG Method in Qualitative and Quantitative Analysis

    International Nuclear Information System (INIS)

    Shin, Seung Ki; Seong, Poong Hyun

    2009-01-01

    Various researches have been conducted in order to analyze dynamic interactions among components and process variables in nuclear power plants which cannot be handled by static reliability analysis methods such as conventional fault tree and event tree techniques. A dynamic reliability graph with general gates (RGGG) method was proposed for an intuitive modeling of dynamic systems and it enables one to easily analyze huge and complex systems. In this paper, advantages of the dynamic RGGG method are assessed through two stages: system modeling and quantitative analysis. And then a software tool for dynamic RGGG method is introduced and an application to a real dynamic system is accompanied

  15. dcmqi: An Open Source Library for Standardized Communication of Quantitative Image Analysis Results Using DICOM.

    Science.gov (United States)

    Herz, Christian; Fillion-Robin, Jean-Christophe; Onken, Michael; Riesmeier, Jörg; Lasso, Andras; Pinter, Csaba; Fichtinger, Gabor; Pieper, Steve; Clunie, David; Kikinis, Ron; Fedorov, Andriy

    2017-11-01

    Quantitative analysis of clinical image data is an active area of research that holds promise for precision medicine, early assessment of treatment response, and objective characterization of the disease. Interoperability, data sharing, and the ability to mine the resulting data are of increasing importance, given the explosive growth in the number of quantitative analysis methods being proposed. The Digital Imaging and Communications in Medicine (DICOM) standard is widely adopted for image and metadata in radiology. dcmqi (DICOM for Quantitative Imaging) is a free, open source library that implements conversion of the data stored in commonly used research formats into the standard DICOM representation. dcmqi source code is distributed under BSD-style license. It is freely available as a precompiled binary package for every major operating system, as a Docker image, and as an extension to 3D Slicer. Installation and usage instructions are provided in the GitHub repository at https://github.com/qiicr/dcmqi Cancer Res; 77(21); e87-90. ©2017 AACR . ©2017 American Association for Cancer Research.

  16. Computer compensation for NMR quantitative analysis of trace components

    International Nuclear Information System (INIS)

    Nakayama, T.; Fujiwara, Y.

    1981-01-01

    A computer program has been written that determines trace components and separates overlapping components in multicomponent NMR spectra. This program uses the Lorentzian curve as a theoretical curve of NMR spectra. The coefficients of the Lorentzian are determined by the method of least squares. Systematic errors such as baseline/phase distortion are compensated and random errors are smoothed by taking moving averages, so that there processes contribute substantially to decreasing the accumulation time of spectral data. The accuracy of quantitative analysis of trace components has been improved by two significant figures. This program was applied to determining the abundance of 13C and the saponification degree of PVA

  17. Stochastic filtering of quantitative data from STR DNA analysis

    DEFF Research Database (Denmark)

    Tvedebrink, Torben; Eriksen, Poul Svante; Mogensen, Helle Smidt

    due to the apparatus used for measurements). Pull-up effects (more systematic increase caused by overlap in the spectrum) Stutters (peaks located four basepairs before the true peak). We present filtering techniques for all three technical artifacts based on statistical analysis of data from......The quantitative data observed from analysing STR DNA is a mixture of contributions from various sources. Apart from the true allelic peaks, the observed signal consists of at least three components resulting from the measurement technique and the PCR amplification: Background noise (random noise...... controlled experiments conducted at The Section of Forensic Genetics, Department of Forensic Medicine, Faculty of Health Sciences, Universityof Copenhagen, Denmark....

  18. Excitation wavelength selection for quantitative analysis of carotenoids in tomatoes using Raman spectroscopy.

    Science.gov (United States)

    Hara, Risa; Ishigaki, Mika; Kitahama, Yasutaka; Ozaki, Yukihiro; Genkawa, Takuma

    2018-08-30

    The difference in Raman spectra for different excitation wavelengths (532 nm, 785 nm, and 1064 nm) was investigated to identify an appropriate wavelength for the quantitative analysis of carotenoids in tomatoes. For the 532 nm-excited Raman spectra, the intensity of the peak assigned to the carotenoid has no correlation with carotenoid concentration, and the peak shift reflects carotenoid composition changing from lycopene to β-carotene and lutein. Thus, 532 nm-excited Raman spectra are useful for the qualitative analysis of carotenoids. For the 785 nm- and 1064 nm-excited Raman spectra, the peak intensity of the carotenoid showed good correlation with carotenoid concentration; thus, regression models for carotenoid concentration were developed using these Raman spectra and partial least squares regression. A regression model designed using the 785 nm-excited Raman spectra showed a better result than the 532 nm- and 1064 nm-excited Raman spectra. Therefore, it can be concluded that 785 nm is the most suitable excitation wavelength for the quantitative analysis of carotenoid concentration in tomatoes. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Quantitative Risk Analysis: Method And Process

    Directory of Open Access Journals (Sweden)

    Anass BAYAGA

    2010-03-01

    Full Text Available Recent and past studies (King III report, 2009: 73-75; Stoney 2007;Committee of Sponsoring Organisation-COSO, 2004, Bartell, 2003; Liebenberg and Hoyt, 2003; Reason, 2000; Markowitz 1957 lament that although, the introduction of quantifying risk to enhance degree of objectivity in finance for instance was quite parallel to its development in the manufacturing industry, it is not the same in Higher Education Institution (HEI. In this regard, the objective of the paper was to demonstrate the methods and process of Quantitative Risk Analysis (QRA through likelihood of occurrence of risk (phase I. This paper serves as first of a two-phased study, which sampled hundred (100 risk analysts in a University in the greater Eastern Cape Province of South Africa.The analysis of likelihood of occurrence of risk by logistic regression and percentages were conducted to investigate whether there were a significant difference or not between groups (analyst in respect of QRA.The Hosmer and Lemeshow test was non-significant with a chi-square(X2 =8.181; p = 0.300, which indicated that there was a good model fit, since the data did not significantly deviate from the model. The study concluded that to derive an overall likelihood rating that indicated the probability that a potential risk may be exercised within the construct of an associated threat environment, the following governing factors must be considered: (1 threat source motivation and capability (2 nature of the vulnerability (3 existence and effectiveness of current controls (methods and process.

  20. A suite of models to support the quantitative assessment of spread in pest risk analysis

    NARCIS (Netherlands)

    Robinet, C.; Kehlenbeck, H.; Werf, van der W.

    2012-01-01

    In the frame of the EU project PRATIQUE (KBBE-2007-212459 Enhancements of pest risk analysis techniques) a suite of models was developed to support the quantitative assessment of spread in pest risk analysis. This dataset contains the model codes (R language) for the four models in the suite. Three

  1. Verbal Rehearsal and Memory in Children with Closed Head Injury: A Quantitative and Qualitative Analysis.

    Science.gov (United States)

    Harris, Jessica R.

    1996-01-01

    Nine closed head injured (CHI) children (mean age 11 years) with post-onset intervals of 7 months to 8 years were given an overt free recall task. Quantitative analysis suggested inefficient passive rehearsal strategy by severely injured subjects. Qualitative analysis revealed differences between CHI children and controls in rehearsal strategies,…

  2. On the quantitative X-ray phase analysis of R-Co alloys

    International Nuclear Information System (INIS)

    Lyubushkin, V.A.; Lyubushkina, L.M.; Vetoshkin, I.D.

    1982-01-01

    Using the method of quantitative X-ray phase analysis two-phase (RCo 5 -R 2 Co 17 ) alloys Sm-Co and Pr-Co have been studied. The investigations are made using the DRON-2.0 dif,ractometer in filtrated FeKα-radiation. Calibration diagrams for model binary mixtures are built, their use is recommended for express-evaluation of the amount of the phase determined. Test of the technique suggested is carried out

  3. Medical students' and facilitators' experiences of an Early Professional Contact course: active and motivated students, strained facilitators.

    Science.gov (United States)

    von Below, Bernhard; Hellquist, Gunilla; Rödjer, Stig; Gunnarsson, Ronny; Björkelund, Cecilia; Wahlqvist, Mats

    2008-12-02

    Today, medical students are introduced to patient contact, communication skills, and clinical examination in the preclinical years of the curriculum with the purpose of gaining clinical experience. These courses are often evaluated from the student perspective. Reports with an additional emphasis on the facilitator perspective are scarce. According to constructive alignment, an influential concept from research in higher education, the learning climate between students and teachers is also of great importance. In this paper, we approach the learning climate by studying both students' and facilitators' course experiences.In 2001, a new "Early Professional Contact" longitudinal strand through term 1-4, was introduced at the Sahlgrenska Academy, University of Gothenburg, Sweden. General practitioners and hospital specialists were facilitators.The aim of this study was to assess and analyse students' and clinical facilitators' experiences of the Early Professional Contact course and to illuminate facilitators' working conditions. Inspired by a Swedish adaptation of the Course Experience Questionnaire, an Early Professional Contact Questionnaire was constructed. In 2003, on the completion of the first longitudinal strand, a student and facilitator version was distributed to 86 students and 21 facilitators. In the analysis, both Chi-square and the Mann-Whitney tests were used. Sixty students (70%) and 15 facilitators (71%) completed the questionnaire. Both students and facilitators were satisfied with the course. Students reported gaining iiration for their future work as doctors along with increased confidence in meeting patients. They also reported increased motivation for biomedical studies. Differences in attitudes between facilitators and students were found. Facilitators experienced a greater workload, less reasonable demands and less support, than students. In this project, a new Early Professional Contact course was analysed from both student and facilitator

  4. Medical students' and facilitators' experiences of an Early Professional Contact course: Active and motivated students, strained facilitators

    Directory of Open Access Journals (Sweden)

    Gunnarsson Ronny

    2008-12-01

    Full Text Available Abstract Background Today, medical students are introduced to patient contact, communication skills, and clinical examination in the preclinical years of the curriculum with the purpose of gaining clinical experience. These courses are often evaluated from the student perspective. Reports with an additional emphasis on the facilitator perspective are scarce. According to constructive alignment, an influential concept from research in higher education, the learning climate between students and teachers is also of great importance. In this paper, we approach the learning climate by studying both students' and facilitators' course experiences. In 2001, a new "Early Professional Contact" longitudinal strand through term 1–4, was introduced at the Sahlgrenska Academy, University of Gothenburg, Sweden. General practitioners and hospital specialists were facilitators. The aim of this study was to assess and analyse students' and clinical facilitators' experiences of the Early Professional Contact course and to illuminate facilitators' working conditions. Methods Inspired by a Swedish adaptation of the Course Experience Questionnaire, an Early Professional Contact Questionnaire was constructed. In 2003, on the completion of the first longitudinal strand, a student and facilitator version was distributed to 86 students and 21 facilitators. In the analysis, both Chi-square and the Mann-Whitney tests were used. Results Sixty students (70% and 15 facilitators (71% completed the questionnaire. Both students and facilitators were satisfied with the course. Students reported gaining iiration for their future work as doctors along with increased confidence in meeting patients. They also reported increased motivation for biomedical studies. Differences in attitudes between facilitators and students were found. Facilitators experienced a greater workload, less reasonable demands and less support, than students. Conclusion In this project, a new Early

  5. Quantitative MRI analysis of the brain after twenty-two years of neuromyelitis optica indicates focal tissue damage

    DEFF Research Database (Denmark)

    Aradi, Mihaly; Koszegi, Edit; Orsi, Gergely

    2013-01-01

    ). In such abnormal NAWM regions, biexponential diffusion analysis and quantitative spectroscopy indicated extracellular edema and axonal loss, respectively. Repeated analysis 6 months later identified the same alterations. Such patchy alterations were not detectable in the NAWM of the 3 cases with short-term NMO......BACKGROUND: The long-term effect of neuromyelitis optica (NMO) on the brain is not well established. METHODS: After 22 years of NMO, a patient's brain was examined by quantitative T1- and T2-weighted mono- and biexponential diffusion and proton spectroscopy. It was compared to 3 cases with short...

  6. Quantitative coronary plaque analysis predicts high-risk plaque morphology on coronary computed tomography angiography: results from the ROMICAT II trial.

    Science.gov (United States)

    Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros

    2018-02-01

    Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.

  7. Preparing palliative home care nurses to act as facilitators for physicians' learning: Evaluation of a training programme.

    Science.gov (United States)

    Pype, Peter; Mertens, Fien; Wens, Johan; Stes, Ann; Van den Eynden, Bart; Deveugele, Myriam

    2015-05-01

    Palliative care requires a multidisciplinary care team. General practitioners often ask specialised palliative home care teams for support. Working with specialised nurses offers learning opportunities, also called workplace learning. This can be enhanced by the presence of a learning facilitator. To describe the development and evaluation of a training programme for nurses in primary care. The programme aimed to prepare palliative home care team nurses to act as facilitators for general practitioners' workplace learning. A one-group post-test only design (quantitative) and semi-structured interviews (qualitative) were used. A multifaceted train-the-trainer programme was designed. Evaluation was done through assignments with individual feedback, summative assessment through videotaped encounters with simulation-physicians and individual interviews after a period of practice implementation. A total of 35 nurses followed the programme. The overall satisfaction was high. Homework assignments interfered with the practice workload but showed to be fundamental in translating theory into practice. Median score on the summative assessment was 7 out of 14 with range 1-13. Interviews revealed some aspects of the training (e.g. incident analysis) to be too difficult for implementation or to be in conflict with personal preferences (focus on patient care instead of facilitating general practitioners' learning). Training palliative home care team nurses as facilitator of general practitioners' workplace learning is a feasible but complex intervention. Personal characteristics, interpersonal relationships and contextual variables have to be taken into account. Training expert palliative care nurses to facilitate general practitioners' workplace learning requires careful and individualised mentoring. © The Author(s) 2014.

  8. Quantitative analysis of stress thallium-201 studies: comparison of SPET and planar imaging in the detection of CAD

    International Nuclear Information System (INIS)

    Ziada, G.; Hayat, N.; Abdel-Dayem, H.M.; Hassan, I.

    1986-01-01

    The value of thallium-201 tomographic sections in the detection of coronary artery disease is illustrated by comparing visual interpretation (VTS) and quantitative analysis (QTS) with visual planar study (VPS) and quantitative analysis of planar study (QPS), referring to coronary angiography (CA) as the standard technique. It is concluded that visual assessment of single photon emission tomography (VTS) is more valuable than all other techniques (VPS, QPS and QTS) for detecting and localizing coronary artery disease. (UK)

  9. Quantitative Analysis of Venus Radar Backscatter Data in ArcGIS

    Science.gov (United States)

    Long, S. M.; Grosfils, E. B.

    2005-01-01

    Ongoing mapping of the Ganiki Planitia (V14) quadrangle of Venus and definition of material units has involved an integrated but qualitative analysis of Magellan radar backscatter images and topography using standard geomorphological mapping techniques. However, such analyses do not take full advantage of the quantitative information contained within the images. Analysis of the backscatter coefficient allows a much more rigorous statistical comparison between mapped units, permitting first order selfsimilarity tests of geographically separated materials assigned identical geomorphological labels. Such analyses cannot be performed directly on pixel (DN) values from Magellan backscatter images, because the pixels are scaled to the Muhleman law for radar echoes on Venus and are not corrected for latitudinal variations in incidence angle. Therefore, DN values must be converted based on pixel latitude back to their backscatter coefficient values before accurate statistical analysis can occur. Here we present a method for performing the conversions and analysis of Magellan backscatter data using commonly available ArcGIS software and illustrate the advantages of the process for geological mapping.

  10. Quantitative Analysis of Microbes in Water Tank of G.A. Siwabessy Reactor

    International Nuclear Information System (INIS)

    Itjeu Karliana; Diah Dwiana Lestiani

    2003-01-01

    The quality of water in reactor system has an important role because it could effect the function as a coolant and the operation of reactor indirectly. The study of microbe analyzes has been carried out to detect the existence of microbes in water tank and quantitative analyzes of microbes also has been applied as a continuation of the previous study. The samples is taken out from the end side of reactor GA Siwabessy's tank, inoculated in TSA (Tripcase Soy Agar) medium, put in incubator at 30 - 35 o C for 4 days. The results of experiment show the reconfirmation for the existence of bacteria and the un-existence of yield. The quantitative analysis with TPC method show the growth rate of bacteria is twice in 24 hours. (author)

  11. Teaching Fundamental Skills in Microsoft Excel to First-Year Students in Quantitative Analysis

    Science.gov (United States)

    Rubin, Samuel J.; Abrams, Binyomin

    2015-01-01

    Despite their technological savvy, most students entering university lack the necessary computer skills to succeed in a quantitative analysis course, in which they are often expected to input, analyze, and plot results of experiments without any previous formal education in Microsoft Excel or similar programs. This lack of formal education results…

  12. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides,

  13. Addressing the Challenges Related to Transforming Qualitative Into Quantitative Data in Qualitative Comparative Analysis

    NARCIS (Netherlands)

    Block, de Debora; Vis, Barbara

    2018-01-01

    The use of qualitative data has so far received relatively little attention in methodological discussions on qualitative comparative analysis (QCA). This article addresses this lacuna by discussing the challenges researchers face when transforming qualitative data into quantitative data in QCA. By

  14. Using multiple PCR and CE with chemiluminescence detection for simultaneous qualitative and quantitative analysis of genetically modified organism.

    Science.gov (United States)

    Guo, Longhua; Qiu, Bin; Chi, Yuwu; Chen, Guonan

    2008-09-01

    In this paper, an ultrasensitive CE-CL detection system coupled with a novel double-on-column coaxial flow detection interface was developed for the detection of PCR products. A reliable procedure based on this system had been demonstrated for qualitative and quantitative analysis of genetically modified organism-the detection of Roundup Ready Soy (RRS) samples was presented as an example. The promoter, terminator, function and two reference genes of RRS were amplified with multiplex PCR simultaneously. After that, the multiplex PCR products were labeled with acridinium ester at the 5'-terminal through an amino modification and then analyzed by the proposed CE-CL system. Reproducibility of analysis times and peak heights for the CE-CL analysis were determined to be better than 0.91 and 3.07% (RSD, n=15), respectively, for three consecutive days. It was shown that this method could accurately and qualitatively detect RRS standards and the simulative samples. The evaluation in terms of quantitative analysis of RRS provided by this new method was confirmed by comparing our assay results with those of the standard real-time quantitative PCR (RT-QPCR) using SYBR Green I dyes. The results showed a good coherence between the two methods. This approach demonstrated the possibility for accurate qualitative and quantitative detection of GM plants in a single run.

  15. Testicular dysgenesis syndrome and the estrogen hypothesis: a quantitative meta-analysis.

    Science.gov (United States)

    Martin, Olwenn V; Shialis, Tassos; Lester, John N; Scrimshaw, Mark D; Boobis, Alan R; Voulvoulis, Nikolaos

    2008-02-01

    Male reproductive tract abnormalities such as hypospadias and cryptorchidism, and testicular cancer have been proposed to comprise a common syndrome together with impaired spermatogenesis with a common etiology resulting from the disruption of gonadal development during fetal life, the testicular dysgenesis syndrome (TDS). The hypothesis that in utero exposure to estrogenic agents could induce these disorders was first proposed in 1993. The only quantitative summary estimate of the association between prenatal exposure to estrogenic agents and testicular cancer was published over 10 years ago, and other systematic reviews of the association between estrogenic compounds, other than the potent pharmaceutical estrogen diethylstilbestrol (DES), and TDS end points have remained inconclusive. We conducted a quantitative meta-analysis of the association between the end points related to TDS and prenatal exposure to estrogenic agents. Inclusion in this analysis was based on mechanistic criteria, and the plausibility of an estrogen receptor (ER)-alpha-mediated mode of action was specifically explored. We included in this meta-analysis eight studies investigating the etiology of hypospadias and/or cryptorchidism that had not been identified in previous systematic reviews. Four additional studies of pharmaceutical estrogens yielded a statistically significant updated summary estimate for testicular cancer. The doubling of the risk ratios for all three end points investigated after DES exposure is consistent with a shared etiology and the TDS hypothesis but does not constitute evidence of an estrogenic mode of action. Results of the subset analyses point to the existence of unidentified sources of heterogeneity between studies or within the study population.

  16. Quantitative analysis of trivalent uranium and lanthanides in a molten chloride by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Toshiyuki Fujii; Akihiro Uehara; Hajimu Yamana

    2013-01-01

    As an analytical application for pyrochemical reprocessing using molten salts, quantitative analysis of uranium and lanthanides by UV/Vis/NIR absorption spectrophotometry was performed. Electronic absorption spectra of LiCl-KCl eutectic at 773 K including trivalent uranium and eight rare earth elements (Y, La, Ce, Pr, Nd, Sm, Eu, and Gd as fission product elements) were measured in the wavenumber region of 4,500-33,000 cm -1 . The composition of the solutes was simulated for a reductive extraction condition in a pyroreprocessing process for spent nuclear fuels, that is, about 2 wt% U and 0.1-2 wt% rare earth elements. Since U(III) possesses strong absorption bands due to f-d transitions, an optical quartz cell with short light path length of 1 mm was adopted in the analysis. The quantitative analysis of trivalent U, Nd, Pr, and Sm was possible with their f-f transition intensities in the NIR region. The analytical results agree with the prepared concentrations within 2σ experimental uncertainties. (author)

  17. Quantitative analysis of occluded gases in uranium dioxide pellets by the mass spectrometry technique

    International Nuclear Information System (INIS)

    Vega Bustillos, J.O.W.; Rodrigues, C.; Iyer, S.S.

    1981-05-01

    A quantitative analysis of different components of occluded gases except water in uranium dioxide pellets is attempted here. A high temperature vacuum extration system is employed for the liberation and the determination of total volume of the occluded gases. A mass spectrometric technique is employed for the qualitative and quantitative analysis of these gases. The UO 2 pellets are placed in a graphite crucible and are subjected to varing temperatures (1000 0 C - 1700 0 C). The liberated gases are dehydrated and transferred to a measuring unit consisting essentially of a Toepler pump and a McLeod gauge. In this system the total volume of the gases liberated at N. T. P. is determined with a sensitivity of 0.002 cm 3 /g of UO 2 . An aliquot of the liberated gas is introduced into a quadrupole mass spectrometer (VGA-100 Varian Corp.) for the determination of the different components of the gas. On the basis of the analysis suggestions are made for the possible sources of these gas components. (Author) [pt

  18. Quantitative analysis of coupler tuning

    International Nuclear Information System (INIS)

    Zheng Shuxin; Cui Yupeng; Chen Huaibi; Xiao Liling

    2001-01-01

    The author deduces the equation of coupler frequency deviation Δf and coupling coefficient β instead of only giving the adjusting direction in the process of matching coupler, on the basis of coupling-cavity chain equivalent circuits model. According to this equation, automatic measurement and quantitative display are realized on a measuring system. It contributes to industrialization of traveling-wave accelerators for large container inspection systems

  19. Quantitative strain analysis of surfaces and interfaces using extremely asymmetric x-ray diffraction

    International Nuclear Information System (INIS)

    Akimoto, Koichi; Emoto, Takashi

    2010-01-01

    Strain can reduce carrier mobility and the reliability of electronic devices and affect the growth mode of thin films and the stability of nanometer-scale crystals. To control lattice strain, a technique for measuring the minute lattice strain at surfaces and interfaces is needed. Recently, an extremely asymmetric x-ray diffraction method has been developed for this purpose. By employing Darwin's dynamical x-ray diffraction theory, quantitative evaluation of strain at surfaces and interfaces becomes possible. In this paper, we review our quantitative strain analysis studies on native SiO 2 /Si interfaces, reconstructed Si surfaces, Ni/Si(111)-H interfaces, sputtered III-V compound semiconductor surfaces, high-k/Si interfaces, and Au ion-implanted Si. (topical review)

  20. Quantitative quenching evaluation and direct intracellular metabolite analysis in Penicillium chrysogenum.

    Science.gov (United States)

    Meinert, Sabine; Rapp, Sina; Schmitz, Katja; Noack, Stephan; Kornfeld, Georg; Hardiman, Timo

    2013-07-01

    Sustained progress in metabolic engineering methodologies has stimulated new efforts toward optimizing fungal production strains such as through metabolite analysis of Penicillium chrysogenum industrial-scale processes. Accurate intracellular metabolite quantification requires sampling procedures that rapidly stop metabolism (quenching) and avoid metabolite loss via the cell membrane (leakage). When sampling protocols are validated, the quenching efficiency is generally not quantitatively assessed. For fungal metabolomics, quantitative biomass separation using centrifugation is a further challenge. In this study, P. chrysogenum intracellular metabolites were quantified directly from biomass extracts using automated sampling and fast filtration. A master/slave bioreactor concept was applied to provide industrial production conditions. Metabolic activity during sampling was monitored by 13C tracing. Enzyme activities were efficiently stopped and metabolite leakage was absent. This work provides a reliable method for P. chrysogenum metabolomics and will be an essential base for metabolic engineering of industrial processes. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. A Reproducible Computerized Method for Quantitation of Capillary Density using Nailfold Capillaroscopy.

    Science.gov (United States)

    Cheng, Cynthia; Lee, Chadd W; Daskalakis, Constantine

    2015-10-27

    Capillaroscopy is a non-invasive, efficient, relatively inexpensive and easy to learn methodology for directly visualizing the microcirculation. The capillaroscopy technique can provide insight into a patient's microvascular health, leading to a variety of potentially valuable dermatologic, ophthalmologic, rheumatologic and cardiovascular clinical applications. In addition, tumor growth may be dependent on angiogenesis, which can be quantitated by measuring microvessel density within the tumor. However, there is currently little to no standardization of techniques, and only one publication to date reports the reliability of a currently available, complex computer based algorithms for quantitating capillaroscopy data.(1) This paper describes a new, simpler, reliable, standardized capillary counting algorithm for quantitating nailfold capillaroscopy data. A simple, reproducible computerized capillaroscopy algorithm such as this would facilitate more widespread use of the technique among researchers and clinicians. Many researchers currently analyze capillaroscopy images by hand, promoting user fatigue and subjectivity of the results. This paper describes a novel, easy-to-use automated image processing algorithm in addition to a reproducible, semi-automated counting algorithm. This algorithm enables analysis of images in minutes while reducing subjectivity; only a minimal amount of training time (in our experience, less than 1 hr) is needed to learn the technique.

  2. NeuroDebian Virtual Machine Deployment Facilitates Trainee-Driven Bedside Neuroimaging Research.

    Science.gov (United States)

    Cohen, Alexander; Kenney-Jung, Daniel; Botha, Hugo; Tillema, Jan-Mendelt

    2017-01-01

    Freely available software, derived from the past 2 decades of neuroimaging research, is significantly more flexible for research purposes than presently available clinical tools. Here, we describe and demonstrate the utility of rapidly deployable analysis software to facilitate trainee-driven translational neuroimaging research. A recipe and video tutorial were created to guide the creation of a NeuroDebian-based virtual computer that conforms to current neuroimaging research standards and can exist within a HIPAA-compliant system. This allows for retrieval of clinical imaging data, conversion to standard file formats, and rapid visualization and quantification of individual patients' cortical and subcortical anatomy. As an example, we apply this pipeline to a pediatric patient's data to illustrate the advantages of research-derived neuroimaging tools in asking quantitative questions "at the bedside." Our goal is to provide a path of entry for trainees to become familiar with common neuroimaging tools and foster an increased interest in translational research.

  3. A Quantitative Features Analysis of Recommended No- and Low-Cost Preschool E-Books

    Science.gov (United States)

    Parette, Howard P.; Blum, Craig; Luthin, Katie

    2015-01-01

    In recent years, recommended e-books have drawn increasing attention from early childhood education professionals. This study applied a quantitative descriptive features analysis of cost (n = 70) and no-cost (n = 60) e-books recommended by the Texas Computer Education Association. While t tests revealed no statistically significant differences…

  4. New tools for comparing microscopy images : Quantitative analysis of cell types in Bacillus subtilis

    NARCIS (Netherlands)

    van Gestel, Jordi; Vlamakis, Hera; Kolter, Roberto

    2015-01-01

    Fluorescence microscopy is a method commonly used to examine individual differences between bacterial cells, yet many studies still lack a quantitative analysis of fluorescence microscopy data. Here we introduce some simple tools that microbiologists can use to analyze and compare their microscopy

  5. Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis.

    Science.gov (United States)

    Razi Naqvi, K

    2014-04-01

    Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens' theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells.

  6. Attention and emotion : An ERP analysis of facilitated emotional stimulus processing

    OpenAIRE

    Schupp, Harald Thomas; Junghöfer, Markus; Weike, Almut I.; Hamm, Alfons

    2003-01-01

    Recent event-related potential studies observed an early posterior negativity (EPN) reflecting facilitated processing of emotional images. The present study explored if the facilitated processing of emotional pictures is sustained while subjects perform an explicit non-emotional attention task. EEG was recorded from 129 channels while subjects viewed a rapid continuous stream of images containing emotional pictures as well as task-related checkerboard images. As expected, explicit selective a...

  7. iQuantitator: A tool for protein expression inference using iTRAQ

    Directory of Open Access Journals (Sweden)

    Comte-Walters Susana

    2009-10-01

    Full Text Available Abstract Background Isobaric Tags for Relative and Absolute Quantitation (iTRAQ™ [Applied Biosystems] have seen increased application in differential protein expression analysis. To facilitate the growing need to analyze iTRAQ data, especially for cases involving multiple iTRAQ experiments, we have developed a modeling approach, statistical methods, and tools for estimating the relative changes in protein expression under various treatments and experimental conditions. Results This modeling approach provides a unified analysis of data from multiple iTRAQ experiments and links the observed quantity (reporter ion peak area to the experiment design and the calculated quantity of interest (treatment-dependent protein and peptide fold change through an additive model under log transformation. Others have demonstrated, through a case study, this modeling approach and noted the computational challenges of parameter inference in the unbalanced data set typical of multiple iTRAQ experiments. Here we present the development of an inference approach, based on hierarchical regression with batching of regression coefficients and Markov Chain Monte Carlo (MCMC methods that overcomes some of these challenges. In addition to our discussion of the underlying method, we also present our implementation of the software, simulation results, experimental results, and sample output from the resulting analysis report. Conclusion iQuantitator's process-based modeling approach overcomes limitations in current methods and allows for application in a variety of experimental designs. Additionally, hypertext-linked documents produced by the tool aid in the interpretation and exploration of results.

  8. Argumentation: A Methodology to Facilitate Critical Thinking.

    Science.gov (United States)

    Makhene, Agnes

    2017-06-20

    Caring is a difficult nursing activity that involves a complex nature of a human being in need of complex decision-making and problem solving through the critical thinking process. It is mandatory that critical thinking is facilitated in general and in nursing education particularly in order to render care in diverse multicultural patient care settings. This paper aims to describe how argumentation can be used to facilitate critical thinking in learners. A qualitative, exploratory and descriptive design that is contextual was used. Purposive sampling method was used to draw a sample and Miles and Huberman methodology of qualitative analysis was used to analyse data. Lincoln and Guba's strategies were employed to ensure trustworthiness, while Dhai and McQuoid-Mason's principles of ethical consideration were used. Following data analysis the findings were integrated within literature which culminated into the formulation of guidelines that can be followed when using argumentation as a methodology to facilitate critical thinking.

  9. Tannin structural elucidation and quantitative ³¹P NMR analysis. 2. Hydrolyzable tannins and proanthocyanidins.

    Science.gov (United States)

    Melone, Federica; Saladino, Raffaele; Lange, Heiko; Crestini, Claudia

    2013-10-02

    An unprecedented analytical method that allows simultaneous structural and quantitative characterization of all functional groups present in tannins is reported. In situ labeling of all labile H groups (aliphatic and phenolic hydroxyls and carboxylic acids) with a phosphorus-containing reagent (Cl-TMDP) followed by quantitative ³¹P NMR acquisition constitutes a novel fast and reliable analytical tool for the analysis of tannins and proanthocyanidins with significant implications for the fields of food and feed analyses, tannery, and the development of natural polyphenolics containing products.

  10. 3-D visualization and quantitation of microvessels in transparent human colorectal carcinoma [corrected].

    Directory of Open Access Journals (Sweden)

    Yuan-An Liu

    Full Text Available Microscopic analysis of tumor vasculature plays an important role in understanding the progression and malignancy of colorectal carcinoma. However, due to the geometry of blood vessels and their connections, standard microtome-based histology is limited in providing the spatial information of the vascular network with a 3-dimensional (3-D continuum. To facilitate 3-D tissue analysis, we prepared transparent human colorectal biopsies by optical clearing for in-depth confocal microscopy with CD34 immunohistochemistry. Full-depth colons were obtained from colectomies performed for colorectal carcinoma. Specimens were prepared away from (control and at the tumor site. Taking advantage of the transparent specimens, we acquired anatomic information up to 200 μm in depth for qualitative and quantitative analyses of the vasculature. Examples are given to illustrate: (1 the association between the tumor microstructure and vasculature in space, including the perivascular cuffs of tumor outgrowth, and (2 the difference between the 2-D and 3-D quantitation of microvessels. We also demonstrate that the optically cleared mucosa can be retrieved after 3-D microscopy to perform the standard microtome-based histology (H&E staining and immunohistochemistry for systematic integration of the two tissue imaging methods. Overall, we established a new tumor histological approach to integrate 3-D imaging, illustration, and quantitation of human colonic microvessels in normal and cancerous specimens. This approach has significant promise to work with the standard histology to better characterize the tumor microenvironment in colorectal carcinoma.

  11. Quantitative analysis of Al-Si alloy using calibration free laser induced breakdown spectroscopy (CF-LIBS)

    Science.gov (United States)

    Shakeel, Hira; Haq, S. U.; Aisha, Ghulam; Nadeem, Ali

    2017-06-01

    The quantitative analysis of the standard aluminum-silicon alloy has been performed using calibration free laser induced breakdown spectroscopy (CF-LIBS). The plasma was produced using the fundamental harmonic (1064 nm) of the Nd: YAG laser and the emission spectra were recorded at 3.5 μs detector gate delay. The qualitative analysis of the emission spectra confirms the presence of Mg, Al, Si, Ti, Mn, Fe, Ni, Cu, Zn, Sn, and Pb in the alloy. The background subtracted and self-absorption corrected emission spectra were used for the estimation of plasma temperature as 10 100 ± 300 K. The plasma temperature and self-absorption corrected emission lines of each element have been used for the determination of concentration of each species present in the alloy. The use of corrected emission intensities and accurate evaluation of plasma temperature yield reliable quantitative analysis up to a maximum 2.2% deviation from reference sample concentration.

  12. Quantitative analysis of lead in polysulfide-based impression material

    Directory of Open Access Journals (Sweden)

    Aparecida Silva Braga

    2007-06-01

    Full Text Available Permlastic® is a polysulfide-based impression material widely used by dentists in Brazil. It is composed of a base paste and a catalyzer containing lead dioxide. The high toxicity of lead to humans is ground for much concern, since it can attack various systems and organs. The present study involved a quantitative analysis of the concentration of lead in the material Permlastic®. The lead was determined by plasma-induced optical emission spectrometry (Varian model Vista. The percentages of lead found in the two analyzed lots were 38.1 and 40.8%. The lead concentrations in the material under study were high, but the product’s packaging contained no information about these concentrations.

  13. Diagnostic value of (99m)Tc-3PRGD2 scintimammography for differentiation of malignant from benign breast lesions: Comparison of visual and semi-quantitative analysis.

    Science.gov (United States)

    Chen, Qianqian; Xie, Qian; Zhao, Min; Chen, Bin; Gao, Shi; Zhang, Haishan; Xing, Hua; Ma, Qingjie

    2015-01-01

    To compare the diagnostic value of visual and semi-quantitative analysis of technetium-99m-poly-ethylene glycol, 4-arginine-glycine-aspartic acid ((99m)Tc-3PRGD2) scintimammography (SMG) for better differentiation of benign from malignant breast masses, and also investigate the incremental role of semi-quantitative index of SMG. A total of 72 patients with breast lesions were included in the study. Technetium-99m-3PRGD2 SMG was performed with single photon emission computed tomography (SPET) at 60 min after intravenous injection of 749 ± 86MBq of the radiotracer. Images were evaluated by visual interpretation and semi-quantitative indices of tumor to non-tumor (T/N) ratios, which were compared with pathology results. Receiver operating characteristics (ROC) curve analyses were performed to determine the optimal visual grade, to calculate cut-off values of semi-quantitative indices, and to compare visual and semi-quantitative diagnostic values. Among the 72 patients, 89 lesions were confirmed by histopathology after fine needle aspiration biopsy or surgery, 48 malignant and 41 benign lesions. The mean T/N ratio of (99m)Tc-3PRGD2 SMG in malignant lesions was significantly higher than that in benign lesions (Pvalue for the detection of primary breast cancer, the sensitivity, specificity and accuracy were 81.3%, 70.7%, and 76.4%, respectively. When a T/N ratio of 2.01 was used as cut-off value, the sensitivity, specificity and accuracy were 79.2%, 75.6%, and 77.5%, respectively. According to ROC analysis, the area under the curve for semi-quantitative analysis was higher than that for visual analysis, but the statistical difference was not significant (P=0.372). Compared with visual analysis or semi-quantitative analysis alone, the sensitivity, specificity and accuracy of visual analysis combined with semi-quantitative analysis in diagnosing primary breast cancer were higher, being: 87.5%, 82.9%, and 85.4%, respectively. The area under the curve was 0.891. Results of

  14. Quantitative analysis of real-time radiographic systems

    International Nuclear Information System (INIS)

    Barker, M.D.; Condon, P.E.; Barry, R.C.; Betz, R.A.; Klynn, L.M.

    1988-01-01

    A method was developed which yields quantitative information on the spatial resolution, contrast sensitivity, image noise, and focal spot size from real time radiographic images. The method uses simple image quality indicators and computer programs which make it possible to readily obtain quantitative performance measurements of single or multiple radiographic systems. It was used for x-ray and optical images to determine which component of the system was not operating up to standard. Focal spot size was monitored by imaging a bar pattern. This paper constitutes the second progress report on the development of the camera and radiation image quality indicators

  15. MRI and image quantitation for drug assessment - growth effects of anabolic steroids and precursors.

    Science.gov (United States)

    Tang, Haiying; Wu, Ed; Vasselli, Joseph

    2005-01-01

    MRI and image quantitation play an expanding role in modern drug research, because MRI offers high resolution and non-invasive ability, and provides excellent soft tissue contrast. Moreover, with development of effective image segmentation and analysis methods, in-vivo and serial tissue growth measurements could be assessed. In the study, MR image acquisition and analysis protocol were established and validated for investigating the effects of anabolic steroids and precursors on muscle growth and body composition in a guinea pig model. Semi-automatic and interactive segmentation methods were developed to accurately label the tissue of interest for tissue volume estimation. In addition, a longitudinal tissue area outlining procedure was proposed for study of tissue geometric features in relation to tissue growth. Finally, a fully automatic data retrieval and analysis scheme was implemented to facilitate the overall huge amount of image quantitation, statistical analysis, as well as study group comparisons. As a result, highly significant differences in muscle and organ growth were detected between intact and castrated guinea pigs using the selected anabolic steroids, indicating the viability of employing such protocol to assess other anabolic steroids. Furthermore, the anabolic potential of selected steroid precursors and their effects on muscle growth, in comparison with that in respective positive control groups of castrated guinea pigs, were evaluated with the proposed protocol.

  16. EBprot: Statistical analysis of labeling-based quantitative proteomics data.

    Science.gov (United States)

    Koh, Hiromi W L; Swa, Hannah L F; Fermin, Damian; Ler, Siok Ghee; Gunaratne, Jayantha; Choi, Hyungwon

    2015-08-01

    Labeling-based proteomics is a powerful method for detection of differentially expressed proteins (DEPs). The current data analysis platform typically relies on protein-level ratios, which is obtained by summarizing peptide-level ratios for each protein. In shotgun proteomics, however, some proteins are quantified with more peptides than others, and this reproducibility information is not incorporated into the differential expression (DE) analysis. Here, we propose a novel probabilistic framework EBprot that directly models the peptide-protein hierarchy and rewards the proteins with reproducible evidence of DE over multiple peptides. To evaluate its performance with known DE states, we conducted a simulation study to show that the peptide-level analysis of EBprot provides better receiver-operating characteristic and more accurate estimation of the false discovery rates than the methods based on protein-level ratios. We also demonstrate superior classification performance of peptide-level EBprot analysis in a spike-in dataset. To illustrate the wide applicability of EBprot in different experimental designs, we applied EBprot to a dataset for lung cancer subtype analysis with biological replicates and another dataset for time course phosphoproteome analysis of EGF-stimulated HeLa cells with multiplexed labeling. Through these examples, we show that the peptide-level analysis of EBprot is a robust alternative to the existing statistical methods for the DE analysis of labeling-based quantitative datasets. The software suite is freely available on the Sourceforge website http://ebprot.sourceforge.net/. All MS data have been deposited in the ProteomeXchange with identifier PXD001426 (http://proteomecentral.proteomexchange.org/dataset/PXD001426/). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Multispectral colour analysis for quantitative evaluation of pseudoisochromatic color deficiency tests

    Science.gov (United States)

    Ozolinsh, Maris; Fomins, Sergejs

    2010-11-01

    Multispectral color analysis was used for spectral scanning of Ishihara and Rabkin color deficiency test book images. It was done using tunable liquid-crystal LC filters built in the Nuance II analyzer. Multispectral analysis keeps both, information on spatial content of tests and on spectral content. Images were taken in the range of 420-720nm with a 10nm step. We calculated retina neural activity charts taking into account cone sensitivity functions, and processed charts in order to find the visibility of latent symbols in color deficiency plates using cross-correlation technique. In such way the quantitative measure is found for each of diagnostics plate for three different color deficiency carrier types - protanopes, deutanopes and tritanopes. Multispectral color analysis allows to determine the CIE xyz color coordinates of pseudoisochromatic plate design elements and to perform statistical analysis of these data to compare the color quality of available color deficiency test books.

  18. Automated quantitative cytological analysis using portable microfluidic microscopy.

    Science.gov (United States)

    Jagannadh, Veerendra Kalyan; Murthy, Rashmi Sreeramachandra; Srinivasan, Rajesh; Gorthi, Sai Siva

    2016-06-01

    In this article, a portable microfluidic microscopy based approach for automated cytological investigations is presented. Inexpensive optical and electronic components have been used to construct a simple microfluidic microscopy system. In contrast to the conventional slide-based methods, the presented method employs microfluidics to enable automated sample handling and image acquisition. The approach involves the use of simple in-suspension staining and automated image acquisition to enable quantitative cytological analysis of samples. The applicability of the presented approach to research in cellular biology is shown by performing an automated cell viability assessment on a given population of yeast cells. Further, the relevance of the presented approach to clinical diagnosis and prognosis has been demonstrated by performing detection and differential assessment of malaria infection in a given sample. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Quantitative analysis of fission products by γ spectrography

    International Nuclear Information System (INIS)

    Malet, G.

    1962-01-01

    The activity of the fission products present in treated solutions of irradiated fuels is given as a function of the time of cooling and of the irradiation time. The variation of the ratio ( 144 Ce + 144 Pr activity)/ 137 Cs activity) as a function of these same parameters is also given. From these results a method is deduced giving the 'age' of the solution analyzed. By γ-scintillation spectrography it was possible to estimate the following elements individually: 141 Ce, 144 Ce + 144 Pr, 103 Ru, 106 Ru + 106 Rh, 137 Cs, 95 Zr + 95 Nb. Yield curves are given for the case of a single emitter. Of the various existing methods, that of the least squares was used for the quantitative analysis of the afore-mentioned fission products. The accuracy attained varies from 3 to 10%. (author) [fr

  20. Quantitative 3D analysis of bone in hip osteoarthritis using clinical computed tomography

    International Nuclear Information System (INIS)

    Turmezei, Tom D.; Treece, Graham M.; Gee, Andrew H.; Fotiadou, Anastasia F.; Poole, Kenneth E.S.

    2016-01-01

    To assess the relationship between proximal femoral cortical bone thickness and radiological hip osteoarthritis using quantitative 3D analysis of clinical computed tomography (CT) data. Image analysis was performed on clinical CT imaging data from 203 female volunteers with a technique called cortical bone mapping (CBM). Colour thickness maps were created for each proximal femur. Statistical parametric mapping was performed to identify statistically significant differences in cortical bone thickness that corresponded with the severity of radiological hip osteoarthritis. Kellgren and Lawrence (K and L) grade, minimum joint space width (JSW) and a novel CT-based osteophyte score were also blindly assessed from the CT data. For each increase in K and L grade, cortical thickness increased by up to 25 % in distinct areas of the superolateral femoral head-neck junction and superior subchondral bone plate. For increasing severity of CT osteophytes, the increase in cortical thickness was more circumferential, involving a wider portion of the head-neck junction, with up to a 7 % increase in cortical thickness per increment in score. Results were not significant for minimum JSW. These findings indicate that quantitative 3D analysis of the proximal femur can identify changes in cortical bone thickness relevant to structural hip osteoarthritis. (orig.)

  1. Pattern decomposition and quantitative-phase analysis in pulsed neutron transmission

    International Nuclear Information System (INIS)

    Steuwer, A.; Santisteban, J.R.; Withers, P.J.; Edwards, L.

    2004-01-01

    Neutron diffraction methods provide accurate quantitative insight into material properties with applications ranging from fundamental physics to applied engineering research. Neutron radiography or tomography on the other hand, are useful tools in the non-destructive spatial imaging of materials or engineering components, but are less accurate with respect to any quantitative analysis. It is possible to combine the advantages of diffraction and radiography using pulsed neutron transmission in a novel way. Using a pixellated detector at a time-of-flight source it is possible to collect 2D 'images' containing a great deal of interesting information in the thermal regime. This together with the unprecedented intensities available at spallation sources and improvements in computing power allow for a re-assessment of the transmission methods. It opens the possibility of simultaneous imaging of diverse material properties such as strain or temperature, as well as the variation in attenuation, and can assist in the determination of phase volume fraction. Spatial and time resolution (for dynamic experiment) are limited only by the detector technology and the intensity of the source. In this example, phase information contained in the cross-section is extracted from Bragg edges using an approach similar to pattern decomposition

  2. Visualisation and quantitative analysis of the rodent malaria liver stage by real time imaging.

    NARCIS (Netherlands)

    Ploemen, I.H.J.; Prudencio, M.; Douradinha, B.G.; Ramesar, J.; Fonager, J.; Gemert, G.J.A. van; Luty, A.J.F.; Hermsen, C.C.; Sauerwein, R.W.; Baptista, F.G.; Mota, M.M.; Waters, A.P.; Que, I.; Lowik, C.W.G.M.; Khan, S.M.; Janse, C.J.; Franke-Fayard, B.

    2009-01-01

    The quantitative analysis of Plasmodium development in the liver in laboratory animals in cultured cells is hampered by low parasite infection rates and the complicated methods required to monitor intracellular development. As a consequence, this important phase of the parasite's life cycle has been

  3. The incidence of Grey Literature in online databases : a quantitative analysis

    OpenAIRE

    Luzi, Daniela (CNR-ISRDS); GreyNet, Grey Literature Network Service

    1994-01-01

    This study aims to verify the diffusion and distribution of Grey Literature (GL) documents in commercially available online databases. It has been undertaken due to the growing importance of GL in the field of information and documentation, on the one hand, and the increasing supply of online databases, on the other hand. The work is divided into two parts. The first provides the results of a previous quantitative analysis of databases containing GL documents. Using a top-down methodology, i....

  4. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    Directory of Open Access Journals (Sweden)

    Jamshed Haneef

    2013-10-01

    Full Text Available Liquid chromatography tandem mass chromatography (LC–MS/MS is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase as well as different acquisition modes (SIM, MRM for quantitative analysis of glucocorticoids and stimulants. This review is not meant to be exhaustive but rather to provide a general overview for detection and confirmation of target drugs using LC–MS/MS and thus useful in the doping analysis, toxicological studies as well as in pharmaceutical analysis. Keywords: LC–MS/MS, Ionization techniques, Glucocorticoids, Stimulants, Hyphenated techniques, Biological fluid

  5. Development and applications of quantitative NMR spectroscopy

    International Nuclear Information System (INIS)

    Yamazaki, Taichi

    2016-01-01

    Recently, quantitative NMR spectroscopy has attracted attention as an analytical method which can easily secure traceability to SI unit system, and discussions about its accuracy and inaccuracy are also started. This paper focuses on the literatures on the advancement of quantitative NMR spectroscopy reported between 2009 and 2016, and introduces both NMR measurement conditions and actual analysis cases in quantitative NMR. The quantitative NMR spectroscopy using an internal reference method enables accurate quantitative analysis with a quick and versatile way in general, and it is possible to obtain the precision sufficiently applicable to the evaluation of pure substances and standard solutions. Since the external reference method can easily prevent contamination to samples and the collection of samples, there are many reported cases related to the quantitative analysis of biologically related samples and highly scarce natural products in which NMR spectra are complicated. In the precision of quantitative NMR spectroscopy, the internal reference method is superior. As the quantitative NMR spectroscopy widely spreads, discussions are also progressing on how to utilize this analytical method as the official methods in various countries around the world. In Japan, this method is listed in the Pharmacopoeia and Japanese Standard of Food Additives, and it is also used as the official method for purity evaluation. In the future, this method will be expected to spread as the general-purpose analysis method that can ensure traceability to SI unit system. (A.O.)

  6. Common and distinct neural correlates of personal and vicarious reward: A quantitative meta-analysis

    Science.gov (United States)

    Morelli, Sylvia A.; Sacchet, Matthew D.; Zaki, Jamil

    2015-01-01

    Individuals experience reward not only when directly receiving positive outcomes (e.g., food or money), but also when observing others receive such outcomes. This latter phenomenon, known as vicarious reward, is a perennial topic of interest among psychologists and economists. More recently, neuroscientists have begun exploring the neuroanatomy underlying vicarious reward. Here we present a quantitative whole-brain meta-analysis of this emerging literature. We identified 25 functional neuroimaging studies that included contrasts between vicarious reward and a neutral control, and subjected these contrasts to an activation likelihood estimate (ALE) meta-analysis. This analysis revealed a consistent pattern of activation across studies, spanning structures typically associated with the computation of value (especially ventromedial prefrontal cortex) and mentalizing (including dorsomedial prefrontal cortex and superior temporal sulcus). We further quantitatively compared this activation pattern to activation foci from a previous meta-analysis of personal reward. Conjunction analyses yielded overlapping VMPFC activity in response to personal and vicarious reward. Contrast analyses identified preferential engagement of the nucleus accumbens in response to personal as compared to vicarious reward, and in mentalizing-related structures in response to vicarious as compared to personal reward. These data shed light on the common and unique components of the reward that individuals experience directly and through their social connections. PMID:25554428

  7. Quantitative image analysis in sonograms of the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Catherine, Skouroliakou [A' Department of Radiology, University of Athens, Vas.Sophias Ave, Athens 11528 (Greece); Maria, Lyra [A' Department of Radiology, University of Athens, Vas.Sophias Ave, Athens 11528 (Greece)]. E-mail: mlyra@pindos.uoa.gr; Aristides, Antoniou [A' Department of Radiology, University of Athens, Vas.Sophias Ave, Athens 11528 (Greece); Lambros, Vlahos [A' Department of Radiology, University of Athens, Vas.Sophias Ave, Athens 11528 (Greece)

    2006-12-20

    High-resolution, real-time ultrasound is a routine examination for assessing the disorders of the thyroid gland. However, the current diagnosis practice is based mainly on qualitative evaluation of the resulting sonograms, therefore depending on the physician's experience. Computerized texture analysis is widely employed in sonographic images of various organs (liver, breast), and it has been proven to increase the sensitivity of diagnosis by providing a better tissue characterization. The present study attempts to characterize thyroid tissue by automatic texture analysis. The texture features that are calculated are based on co-occurrence matrices as they have been proposed by Haralick. The sample consists of 40 patients. For each patient two sonographic images (one for each lobe) are recorded in DICOM format. The lobe is manually delineated in each sonogram, and the co-occurrence matrices for 52 separation vectors are calculated. The texture features extracted from each one of these matrices are: contrast, correlation, energy and homogeneity. Primary component analysis is used to select the optimal set of features. The statistical analysis resulted in the extraction of 21 optimal descriptors. The optimal descriptors are all co-occurrence parameters as the first-order statistics did not prove to be representative of the images characteristics. The bigger number of components depends mainly on correlation for very close or very far distances. The results indicate that quantitative analysis of thyroid sonograms can provide an objective characterization of thyroid tissue.

  8. The quantitative methods boot camp: teaching quantitative thinking and computing skills to graduate students in the life sciences.

    Directory of Open Access Journals (Sweden)

    Melanie I Stefan

    2015-04-01

    Full Text Available The past decade has seen a rapid increase in the ability of biologists to collect large amounts of data. It is therefore vital that research biologists acquire the necessary skills during their training to visualize, analyze, and interpret such data. To begin to meet this need, we have developed a "boot camp" in quantitative methods for biology graduate students at Harvard Medical School. The goal of this short, intensive course is to enable students to use computational tools to visualize and analyze data, to strengthen their computational thinking skills, and to simulate and thus extend their intuition about the behavior of complex biological systems. The boot camp teaches basic programming using biological examples from statistics, image processing, and data analysis. This integrative approach to teaching programming and quantitative reasoning motivates students' engagement by demonstrating the relevance of these skills to their work in life science laboratories. Students also have the opportunity to analyze their own data or explore a topic of interest in more detail. The class is taught with a mixture of short lectures, Socratic discussion, and in-class exercises. Students spend approximately 40% of their class time working through both short and long problems. A high instructor-to-student ratio allows students to get assistance or additional challenges when needed, thus enhancing the experience for students at all levels of mastery. Data collected from end-of-course surveys from the last five offerings of the course (between 2012 and 2014 show that students report high learning gains and feel that the course prepares them for solving quantitative and computational problems they will encounter in their research. We outline our course here which, together with the course materials freely available online under a Creative Commons License, should help to facilitate similar efforts by others.

  9. The quantitative methods boot camp: teaching quantitative thinking and computing skills to graduate students in the life sciences.

    Science.gov (United States)

    Stefan, Melanie I; Gutlerner, Johanna L; Born, Richard T; Springer, Michael

    2015-04-01

    The past decade has seen a rapid increase in the ability of biologists to collect large amounts of data. It is therefore vital that research biologists acquire the necessary skills during their training to visualize, analyze, and interpret such data. To begin to meet this need, we have developed a "boot camp" in quantitative methods for biology graduate students at Harvard Medical School. The goal of this short, intensive course is to enable students to use computational tools to visualize and analyze data, to strengthen their computational thinking skills, and to simulate and thus extend their intuition about the behavior of complex biological systems. The boot camp teaches basic programming using biological examples from statistics, image processing, and data analysis. This integrative approach to teaching programming and quantitative reasoning motivates students' engagement by demonstrating the relevance of these skills to their work in life science laboratories. Students also have the opportunity to analyze their own data or explore a topic of interest in more detail. The class is taught with a mixture of short lectures, Socratic discussion, and in-class exercises. Students spend approximately 40% of their class time working through both short and long problems. A high instructor-to-student ratio allows students to get assistance or additional challenges when needed, thus enhancing the experience for students at all levels of mastery. Data collected from end-of-course surveys from the last five offerings of the course (between 2012 and 2014) show that students report high learning gains and feel that the course prepares them for solving quantitative and computational problems they will encounter in their research. We outline our course here which, together with the course materials freely available online under a Creative Commons License, should help to facilitate similar efforts by others.

  10. New Approaches to Transport Project Assessment: Reference Scenario Forecasting and Quantitative Risk Analysis

    DEFF Research Database (Denmark)

    Salling, Kim Bang

    2010-01-01

    however has proved that the point estimates derived from such analyses are embedded with a large degree of uncertainty. Thus, a new scheme was proposed in terms of applying quantitative risk analysis (QRA) and Monte Carlo simulation in order to represent the uncertainties within the cost-benefit analysis....... Additionally, the handling of uncertainties is supplemented by making use of the principle of Optimism Bias, which depicts the historical tendency of overestimating transport related benefits (user demands i.e. travel time savings) and underestimating investment costs....

  11. Quantitative autoradiography of neurochemicals

    International Nuclear Information System (INIS)

    Rainbow, T.C.; Biegon, A.; Bleisch, W.V.

    1982-01-01

    Several new methods have been developed that apply quantitative autoradiography to neurochemistry. These methods are derived from the 2-deoxyglucose (2DG) technique of Sokoloff (1), which uses quantitative autoradiography to measure the rate of glucose utilization in brain structures. The new methods allow the measurement of the rate of cerbral protein synthesis and the levels of particular neurotransmitter receptors by quantitative autoradiography. As with the 2DG method, the new techniques can measure molecular levels in micron-sized brain structures; and can be used in conjunction with computerized systems of image processing. It is possible that many neurochemical measurements could be made by computerized analysis of quantitative autoradiograms

  12. Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soyoung [Department of Radiation Oncology, University Hospitals Case and Medical Center, Cleveland, Ohio 44106 (United States); Yan, Guanghua; Bassett, Philip; Samant, Sanjiv, E-mail: samant@ufl.edu [Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida 32608 (United States); Gopal, Arun [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States)

    2016-09-15

    Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two

  13. An XRD technique for quantitative phase analysis of Al-U-Zr alloy

    International Nuclear Information System (INIS)

    Khan, K.B.; Kulkarni, N.K.; Jain, G.C.

    2003-01-01

    In several nuclear research reactors all over the world, Al-U alloy is used as fuel. To stabilise less brittle phase UAl 3 in Al-U alloy, a small amount of Zr (1 to 3 wt% ) is added. A rapid, non destructive and simple x-ray diffraction technique has been developed for quantitative phase analysis Al-U-Zr alloy system containing UAl 4 , UAl 3 and Al. (author)

  14. Quantitative analysis of phases by x-ray diffraction and thermogravimetry in Cuban phosphorite ores

    International Nuclear Information System (INIS)

    Casanova Gomez, Abdel; Martinez Montalvo, Asor; Cilano Campos, Guillermo; Arostegui Aguirre, Miladys; Ferreiro Fernandez, Adalyz; Alonso Perez, Jose A.

    2016-01-01

    Phases analysis is performed by instrumental techniques X - ray diffraction and Thermal Analysis in two groups of samples of Cuban minerals carriers'phosphorus, candidates to reference materials. To this end, the variant of structural refinement of the diffraction pattern in the form of adjustment profile is applied, using the Full prof program of Juan Rodriguez-Carvajal. This analysis is the first step to develop the standard specification of these resources and classify them as phosphate rock and / or phospharite from their mass content. The statistical evaluation of the uncertainty of the quantitative analysis (standard deviation) was carried out in ten replicate samples of phosphate rock and eight of phosphate from the field Trinidad de Guedes. The qualitative phase analysis reflected the following phase composition: carbonate fluoroapatite (CFA), Calcite, Quartz and Halloysite (present only in the clayey granular phosphorite ore; FGA). By the method of setting pattern powder diffraction profile, the quantitative phase composition is reported in the sample FGA: 87 (2) % of CFA, 4 (1) % of Calcite, 1% Quartz, and 8 (3) % Halloysite. For granular limestone ore (FGC), the following contents were obtained: 87 (3) % Calcite, 8 (3) % of CFA and 5 (1) % Quartz: The obtained values are corroborated by Thermogravimetric Analysis (TG) through the calculation of the mass content of the thermally active phases (Calcite and CFA) in the range (27-10000 0 C), confirming the validity of the results of XRD. (Author)

  15. Methodology for Quantitative Analysis of Large Liquid Samples with Prompt Gamma Neutron Activation Analysis using Am-Be Source

    International Nuclear Information System (INIS)

    Idiri, Z.; Mazrou, H.; Beddek, S.; Amokrane, A.

    2009-01-01

    An optimized set-up for prompt gamma neutron activation analysis (PGNAA) with Am-Be source is described and used for large liquid samples analysis. A methodology for quantitative analysis is proposed: it consists on normalizing the prompt gamma count rates with thermal neutron flux measurements carried out with He-3 detector and gamma attenuation factors calculated using MCNP-5. The relative and absolute methods are considered. This methodology is then applied to the determination of cadmium in industrial phosphoric acid. The same sample is then analyzed by inductively coupled plasma (ICP) method. Our results are in good agreement with those obtained with ICP method.

  16. Meta-Analysis of Results from Quantitative Trait Loci Mapping Studies on Pig Chromosome 4

    NARCIS (Netherlands)

    Moraes Silva, De K.M.; Bastiaansen, J.W.M.; Knol, E.F.; Merks, J.W.M.; Lopes, P.S.; Guimaraes, R.M.; Arendonk, van J.A.M.

    2011-01-01

    Meta-analysis of results from multiple studies could lead to more precise quantitative trait loci (QTL) position estimates compared to the individual experiments. As the raw data from many different studies are not readily available, the use of results from published articles may be helpful. In this

  17. Quantitative analysis of psychological personality for NPP operators

    International Nuclear Information System (INIS)

    Gao Jia; Huang Xiangrui

    1998-01-01

    The author introduces the relevant personality quantitative psychological research work carried out by 'Prognoz' Laboratory and Taiwan, and presents the primary results of the research for Chinese Nuclear Power Plant (NPP) operator's psychological personality assessment, which based on the survey of MMPI, and presents the main contents for the personality quantitative psychological research in NPP of China. And emphasizes the need to carry out psychological selection and training in nuclear industry

  18. A Simple Linear Regression Method for Quantitative Trait Loci Linkage Analysis With Censored Observations

    OpenAIRE

    Anderson, Carl A.; McRae, Allan F.; Visscher, Peter M.

    2006-01-01

    Standard quantitative trait loci (QTL) mapping techniques commonly assume that the trait is both fully observed and normally distributed. When considering survival or age-at-onset traits these assumptions are often incorrect. Methods have been developed to map QTL for survival traits; however, they are both computationally intensive and not available in standard genome analysis software packages. We propose a grouped linear regression method for the analysis of continuous survival data. Using...

  19. An unconventional method of quantitative microstructural analysis

    International Nuclear Information System (INIS)

    Rastani, M.

    1995-01-01

    The experiment described here introduces a simple methodology which could be used to replace the time-consuming and expensive conventional methods of metallographic and quantitative analysis of thermal treatment effect on microstructure. The method is ideal for the microstructural evaluation of tungsten filaments and other wire samples such as copper wire which can be conveniently coiled. Ten such samples were heat treated by ohmic resistance at temperatures which were expected to span the recrystallization range. After treatment, the samples were evaluated in the elastic recovery test. The normalized elastic recovery factor was defined in terms of these deflections. Experimentally it has shown that elastic recovery factor depends on the degree of recrystallization. In other words this factor is used to determine the fraction of unrecrystallized material. Because the elastic recovery method examines the whole filament rather than just one section through the filament as in metallographical method, it more accurately measures the degree of recrystallization. The method also takes a considerably shorter time and cost compared to the conventional method

  20. Risk Factors for Chronic Subdural Hematoma Recurrence Identified Using Quantitative Computed Tomography Analysis of Hematoma Volume and Density.

    Science.gov (United States)

    Stavrinou, Pantelis; Katsigiannis, Sotirios; Lee, Jong Hun; Hamisch, Christina; Krischek, Boris; Mpotsaris, Anastasios; Timmer, Marco; Goldbrunner, Roland

    2017-03-01

    Chronic subdural hematoma (CSDH), a common condition in elderly patients, presents a therapeutic challenge with recurrence rates of 33%. We aimed to identify specific prognostic factors for recurrence using quantitative analysis of hematoma volume and density. We retrospectively reviewed radiographic and clinical data of 227 CSDHs in 195 consecutive patients who underwent evacuation of the hematoma through a single burr hole, 2 burr holes, or a mini-craniotomy. To examine the relationship between hematoma recurrence and various clinical, radiologic, and surgical factors, we used quantitative image-based analysis to measure the hematoma and trapped air volumes and the hematoma densities. Recurrence of CSDH occurred in 35 patients (17.9%). Multivariate logistic regression analysis revealed that the percentage of hematoma drained and postoperative CSDH density were independent risk factors for recurrence. All 3 evacuation methods were equally effective in draining the hematoma (71.7% vs. 73.7% vs. 71.9%) without observable differences in postoperative air volume captured in the subdural space. Quantitative image analysis provided evidence that percentage of hematoma drained and postoperative CSDH density are independent prognostic factors for subdural hematoma recurrence. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Quantitative analysis on the urban flood mitigation effect by the extensive green roof system.

    Science.gov (United States)

    Lee, J Y; Moon, H J; Kim, T I; Kim, H W; Han, M Y

    2013-10-01

    Extensive green-roof systems are expected to have a synergetic effect in mitigating urban runoff, decreasing temperature and supplying water to a building. Mitigation of runoff through rainwater retention requires the effective design of a green-roof catchment. This study identified how to improve building runoff mitigation through quantitative analysis of an extensive green-roof system. Quantitative analysis of green-roof runoff characteristics indicated that the extensive green roof has a high water-retaining capacity response to rainfall of less than 20 mm/h. As the rainfall intensity increased, the water-retaining capacity decreased. The catchment efficiency of an extensive green roof ranged from 0.44 to 0.52, indicating reduced runoff comparing with efficiency of 0.9 for a concrete roof. Therefore, extensive green roofs are an effective storm water best-management practice and the proposed parameters can be applied to an algorithm for rainwater-harvesting tank design. © 2013 Elsevier Ltd. All rights reserved.

  2. Quantitative analysis of 39 polybrominated diphenyl ethers by isotope dilution GC/low-resolution MS.

    Science.gov (United States)

    Ackerman, Luke K; Wilson, Glenn R; Simonich, Staci L

    2005-04-01

    A GC/low-resolution MS method for the quantitative isotope dilution analysis of 39 mono- to heptabrominated diphenyl ethers was developed. The effects of two different ionization sources, electron impact (EI) and electron capture negative ionization (ECNI), and the effects of their parameters on production of high-mass fragment ions [M - xH - yBr](-) specific to PBDEs were investigated. Electron energy, emission current, source temperature, ECNI system pressure, and choice of ECNI reagent gases were optimized. Previously unidentified enhancement of PBDE high-mass fragment ion [M - xH - yBr](-) abundance was achieved. Electron energy had the largest impact on PBDE high-mass fragment ion abundance for both the ECNI and EI sources. By monitoring high-mass fragment ions of PBDEs under optimized ECNI source conditions, quantitative isotope dilution analysis of 39 PBDEs was conducted using nine (13)C(12) labeled PBDEs on a low-resolution MS with low picogram to femtogram instrument detection limits.

  3. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Mo, Shunyan; Dong, Linlin; Hurst, W. Jeffrey; van Breemen, Richard B.

    2014-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measurement of six abundant dietary phytosterols and structurally related triterpene alcohols including brassicasterol, campesterol, cycloartenol, β-sitosterol, stigmasterol, and lupeol in edible oils. Samples were saponified, extracted with hexane and then analyzed using reversed phase HPLC with positive ion atmospheric pressure chemical ionization tandem mass spectrometry and selected reaction monitoring. The utility of the LC-MS-MS method was demonstrated by analyzing 14 edible oils. All six compounds were present in at least some of the edible oils. The most abundant phytosterol in all samples was β-sitosterol, which was highest in corn oil at 4.35 ± 0.03 mg/g, followed by campesterol in canola oil at 1.84 ± 0.01 mg/g. The new LC-MS-MS method for the quantitative analysis of phytosterols provides a combination of speed, selectivity and sensitivity that exceed those of previous assays. PMID:23884629

  4. Quantitative analysis of crystalline pharmaceuticals in tablets by pattern-fitting procedure using X-ray diffraction pattern.

    Science.gov (United States)

    Takehira, Rieko; Momose, Yasunori; Yamamura, Shigeo

    2010-10-15

    A pattern-fitting procedure using an X-ray diffraction pattern was applied to the quantitative analysis of binary system of crystalline pharmaceuticals in tablets. Orthorhombic crystals of isoniazid (INH) and mannitol (MAN) were used for the analysis. Tablets were prepared under various compression pressures using a direct compression method with various compositions of INH and MAN. Assuming that X-ray diffraction pattern of INH-MAN system consists of diffraction intensities from respective crystals, observed diffraction intensities were fitted to analytic expression based on X-ray diffraction theory and separated into two intensities from INH and MAN crystals by a nonlinear least-squares procedure. After separation, the contents of INH were determined by using the optimized normalization constants for INH and MAN. The correction parameter including all the factors that are beyond experimental control was required for quantitative analysis without calibration curve. The pattern-fitting procedure made it possible to determine crystalline phases in the range of 10-90% (w/w) of the INH contents. Further, certain characteristics of the crystals in the tablets, such as the preferred orientation, size of crystallite, and lattice disorder were determined simultaneously. This method can be adopted to analyze compounds whose crystal structures are known. It is a potentially powerful tool for the quantitative phase analysis and characterization of crystals in tablets and powders using X-ray diffraction patterns. Copyright 2010 Elsevier B.V. All rights reserved.

  5. PIQMIe: a web server for semi-quantitative proteomics data management and analysis.

    Science.gov (United States)

    Kuzniar, Arnold; Kanaar, Roland

    2014-07-01

    We present the Proteomics Identifications and Quantitations Data Management and Integration Service or PIQMIe that aids in reliable and scalable data management, analysis and visualization of semi-quantitative mass spectrometry based proteomics experiments. PIQMIe readily integrates peptide and (non-redundant) protein identifications and quantitations from multiple experiments with additional biological information on the protein entries, and makes the linked data available in the form of a light-weight relational database, which enables dedicated data analyses (e.g. in R) and user-driven queries. Using the web interface, users are presented with a concise summary of their proteomics experiments in numerical and graphical forms, as well as with a searchable protein grid and interactive visualization tools to aid in the rapid assessment of the experiments and in the identification of proteins of interest. The web server not only provides data access through a web interface but also supports programmatic access through RESTful web service. The web server is available at http://piqmie.semiqprot-emc.cloudlet.sara.nl or http://www.bioinformatics.nl/piqmie. This website is free and open to all users and there is no login requirement. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. Assessment of a synchrotron X-ray method for quantitative analysis of calcium hydroxide

    International Nuclear Information System (INIS)

    Williams, P. Jason; Biernacki, Joseph J.; Bai Jianming; Rawn, Claudia J.

    2003-01-01

    Thermogravimetric analysis (TGA) and quantitative X-ray diffraction (QXRD) are widely used to determine the calcium hydroxide (CH) content in cementitious systems containing blends of Portland cement, fly ash, blast furnace slag, silica fume and other pozzolanic and hydraulic materials. These techniques, however, are destructive to cement samples and subject to various forms of error. While precise weight losses can be measured by TGA, extracting information from samples with multiple overlapping thermal events is difficult. And, however, while QXRD can offer easier deconvolution, the accuracy for components below about 5 wt.% is typically poor when a laboratory X-ray source is used. Furthermore, the destructive nature of both techniques prevents using them to study the in situ hydration of a single contiguous sample for kinetic analysis. In an attempt to overcome these problems, the present research evaluated the use of synchrotron X-rays for quantitative analysis of CH. A synchrotron X-ray source was used to develop calibration data for quantification of the amount of CH in mixtures with fly ash. These data were compared to conventional laboratory XRD data for like samples. While both methods were found to offer good quantification, synchrotron XRD (SXRD) provided a broader range of detectability and higher accuracy than laboratory diffraction and removed the subjectivity as compared to TGA analysis. Further, the sealed glass capillaries used with the synchrotron source provided a nondestructive closed, in situ environment for tracking hydrating specimens from zero to any desired age

  7. Quantitative analysis of the epitaxial recrystallization effect induced by swift heavy ions in silicon carbide

    International Nuclear Information System (INIS)

    Benyagoub, A.

    2015-01-01

    This paper discusses recent results on the recrystallization effect induced by swift heavy ions (SHI) in pre-damaged silicon carbide. The recrystallization kinetics was followed by using increasing SHI fluences and by starting from different levels of initial damage within the SiC samples. The quantitative analysis of the data shows that the recrystallization rate depends drastically on the local amount of crystalline material: it is nil in fully amorphous regions and becomes more significant with increasing amount of crystalline material. For instance, in samples initially nearly half-disordered, the recrystallization rate per incident ion is found to be 3 orders of magnitude higher than what it is observed with the well-known IBIEC process using low energy ions. This high rate can therefore not be accounted for by the existing IBIEC models. Moreover, decreasing the electronic energy loss leads to a drastic reduction of the recrystallization rate. A comprehensive quantitative analysis of all the experimental results shows that the SHI induced high recrystallization rate can only be explained by a mechanism based on the melting of the amorphous zones through a thermal spike process followed by an epitaxial recrystallization initiated from the neighboring crystalline regions if the size of the latter exceeds a certain critical value. This quantitative analysis also reveals that recent molecular dynamics calculations supposed to reproduce this phenomenon are wrong since they overestimated the recrystallization rate by a factor ∼40.

  8. Quantitative Analysis of the Security of Software-Defined Network Controller Using Threat/Effort Model

    Directory of Open Access Journals (Sweden)

    Zehui Wu

    2017-01-01

    Full Text Available SDN-based controller, which is responsible for the configuration and management of the network, is the core of Software-Defined Networks. Current methods, which focus on the secure mechanism, use qualitative analysis to estimate the security of controllers, leading to inaccurate results frequently. In this paper, we employ a quantitative approach to overcome the above shortage. Under the analysis of the controller threat model we give the formal model results of the APIs, the protocol interfaces, and the data items of controller and further provide our Threat/Effort quantitative calculation model. With the help of Threat/Effort model, we are able to compare not only the security of different versions of the same kind controller but also different kinds of controllers and provide a basis for controller selection and secure development. We evaluated our approach in four widely used SDN-based controllers which are POX, OpenDaylight, Floodlight, and Ryu. The test, which shows the similarity outcomes with the traditional qualitative analysis, demonstrates that with our approach we are able to get the specific security values of different controllers and presents more accurate results.

  9. MEASURING ORGANIZATIONAL CULTURE: A QUANTITATIVE-COMPARATIVE ANALYSIS [doi: 10.5329/RECADM.20100902007

    Directory of Open Access Journals (Sweden)

    Valderí de Castro Alcântara

    2010-11-01

    Full Text Available This article aims at the analysis of the organizational culture at enterprises located in two towns with distinct quantitative traits, Rio Paranaíba and Araxá. While the surveyed enterprises in Rio Paranaíba are mostly micro and small enterprises (86%, in Araxá there are mostly medium and large companies (53%. The overall objective is to verify if there are significant differences in organizational culture among these enterprises and if they can be explained by the organization size. The research was quantitative and instruments for data collection were a questionnaire and a scale for measuring organizational culture containing four dimensions: Hierarchical Distance Index (IDH, Individualism Index (INDI, Masculinity Index (MASC and the Uncertainty Control Index (CINC. Tabulation and analysis of data were performed using the PASW Statistics 18, doing descriptive and inferential statistical procedures. Using a Reduction Factor (-21 the achieved indexes were classified into 5 intensity categories (from "very low" to "very high". The Student t test for two means was performed, revealing significant differences in Hierarchical Distance and Individualism between Araxá and Rio Paranaíba enterprises (p <0.05.   Keywords Organizational Culture; Dimensions of Organizational Culture; Araxá; Rio Paranaíba.

  10. Quantitative analysis of perfumes in talcum powder by using headspace sorptive extraction.

    Science.gov (United States)

    Ng, Khim Hui; Heng, Audrey; Osborne, Murray

    2012-03-01

    Quantitative analysis of perfume dosage in talcum powder has been a challenge due to interference of the matrix and has so far not been widely reported. In this study, headspace sorptive extraction (HSSE) was validated as a solventless sample preparation method for the extraction and enrichment of perfume raw materials from talcum powder. Sample enrichment is performed on a thick film of poly(dimethylsiloxane) (PDMS) coated onto a magnetic stir bar incorporated in a glass jacket. Sampling is done by placing the PDMS stir bar in the headspace vial by using a holder. The stir bar is then thermally desorbed online with capillary gas chromatography-mass spectrometry. The HSSE method is based on the same principles as headspace solid-phase microextraction (HS-SPME). Nevertheless, a relatively larger amount of extracting phase is coated on the stir bar as compared to SPME. Sample amount and extraction time were optimized in this study. The method has shown good repeatability (with relative standard deviation no higher than 12.5%) and excellent linearity with correlation coefficients above 0.99 for all analytes. The method was also successfully applied in the quantitative analysis of talcum powder spiked with perfume at different dosages. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Quali- and quantitative analysis of commercial coffee by NMR

    International Nuclear Information System (INIS)

    Tavares, Leila Aley; Ferreira, Antonio Gilberto

    2006-01-01

    Coffee is one of the beverages most widely consumed in the world and the 'cafezinho' is normally prepared from a blend of roasted powder of two species, Coffea arabica and Coffea canephora. Each one exhibits differences in their taste and in the chemical composition, especially in the caffeine percentage. There are several procedures proposed in the literature for caffeine determination in different samples like soft drinks, coffee, medicines, etc but most of them need a sample workup which involves at least one step of purification. This work describes the quantitative analysis of caffeine using 1 H NMR and the identification of the major components in commercial coffee samples using 1D and 2D NMR techniques without any sample pre-treatment. (author)

  12. Quantitative mineralogical analysis of sandstones using x-ray diffraction techniques

    International Nuclear Information System (INIS)

    Ward, C.R.; Taylor, J.C.

    1999-01-01

    Full text: X-ray diffraction has long been used as a definitive technique for mineral identification based on the measuring the internal atomic or crystal structures present in powdered rocks; soils and other mineral mixtures. Recent developments in data gathering and processing, however, have provided an improved basis for its use as a quantitative tool, determining not only the nature of the minerals but also the relative proportions of the different minerals present. The mineralogy of a series of sandstone samples from the Sydney and Bowen Basins of eastern Australia has been evaluated by X-ray diffraction (XRD) on a quantitative basis using the Australian-developed SIROQUANT data processing technique. Based on Rietveld principles, this technique generates a synthetic X-ray diffractogram by adjusting and combining full-profile patterns of minerals nominated as being present in the sample and interactively matches the synthetic diffractogram under operator instructions to the observed diffractogram of the sample being analysed. The individual mineral patterns may be refined in the process, to allow for variations in crystal structure of individual components or for factors such as preferred orientation in the sample mount. The resulting output provides mass percentages of the different minerals in the mixture, and an estimate of the error associated with each individual percentage determination. The chemical composition of the mineral mixtures indicated by SIROQUANT for each individual sandstone studied was estimated using a spreadsheet routine, and the indicated proportion of each oxide in each sample compared to the actual chemical analysis of the same sandstone as determined independently by X-ray fluorescence spectrometry. The results show a high level of agreement for all major chemical constituents, indicating consistency between the SIROQUANT XRD data and the whole-rock chemical composition. Supplementary testing with a synthetic corundum spike further

  13. Technology-Facilitated Sexual Violence: A Literature Review of Empirical Research.

    Science.gov (United States)

    Henry, Nicola; Powell, Anastasia

    2018-04-01

    Technology-facilitated sexual violence (TFSV) refers to a range of behaviors where digital technologies are used to facilitate both virtual and face-to-face sexually based harms. Such behaviors include online sexual harassment, gender- and sexuality-based harassment, cyberstalking, image-based sexual exploitation, and the use of a carriage service to coerce a victim into an unwanted sexual act. This article reviews the current state of knowledge on these different dimensions, drawing on existing empirical studies. While there is a growing body of research into technology-facilitated harms perpetrated against children and adolescents, there is a dearth of qualitative and quantitative research on TFSV against adults. Moreover, few of the existing studies provide reliable data on the nature, scope, and impacts of TFSV. Preliminary studies, however, indicate that some harms, much like sexual violence more broadly, may be predominantly gender-, sexuality-, and age-based, with young women being overrepresented as victims in some categories. This review collects the empirical evidence to date regarding the prevalence and gender-based nature of TFSV against adults and discusses the implications for policy and programs, as well as suggestions for future research.

  14. DEVELOPMENT OF TECHNIQUES FOR QUANTITATIVE ANALYSIS OF LIME FLOWERS

    Directory of Open Access Journals (Sweden)

    Demyanenko DV

    2016-03-01

    Full Text Available Introduction. The article is devoted to the development of techniques for quantitative analysis of lime flower in order to make amendments to existing pharmacopoeian monographs for this herbal drug. Lime inflorescences contain lipophilic biologically active substances (BAS causing notable antimicrobial and anti-inflammatory effects and also more polar phenolic compounds with antiulcer activity. Considering this, it’s necessary to regulate all these groups of BAS quantitatively. Materials and methods. For this study six batches of lime flowers harvested in 2008-2009 yrs. in Kharkiv, Rivno and Zhitomir regions were used as crude herbal drug. Loss on drying was determined by routine pharmacopoeian procedures. Total content of lipophilic substances was determined gravimetrically after Soxhlet extraction of samples 1, 5, 7 and 10 g in weight with methylene chloride, considering that by its extracting ability this solvent is close to liquefied difluorochloromethane (freon R22 used by us for obtaining of lipophilic complexes. The duration of complete analytical extraction was determined by infusion of six 10 g assays of lime flowers during 1, 2, 3, 4, 5, 6 hours, then quantity of lipophilic extractives was revealed gravimetrically. Quantity of essential oil in lime flowers was evaluated under the procedure of ЕР7, 2.8.12. Weight of the herbal drug sample was 200 g, distillation rate – 2,5- 3,5 ml/min, volume of distillation liquid (water – 500 ml, volume of xylene in the graduated tube – 0,50 ml. Total flavonoid content recalculated to quercetin was determined after hydrolysis with acidified acetone, withdrawing of flavonoid aglycones with ethylacetate and by further spectrophotometry of their complexes with aluminium chloride. All quantitative determinations were replicated five times for each assay. All chemicals and reagents were of analytical grade. Results and discussion. It was found that adequate accuracy of the analysis of lipophilic

  15. Facilitating arrhythmia simulation: the method of quantitative cellular automata modeling and parallel running

    Directory of Open Access Journals (Sweden)

    Mondry Adrian

    2004-08-01

    Full Text Available Abstract Background Many arrhythmias are triggered by abnormal electrical activity at the ionic channel and cell level, and then evolve spatio-temporally within the heart. To understand arrhythmias better and to diagnose them more precisely by their ECG waveforms, a whole-heart model is required to explore the association between the massively parallel activities at the channel/cell level and the integrative electrophysiological phenomena at organ level. Methods We have developed a method to build large-scale electrophysiological models by using extended cellular automata, and to run such models on a cluster of shared memory machines. We describe here the method, including the extension of a language-based cellular automaton to implement quantitative computing, the building of a whole-heart model with Visible Human Project data, the parallelization of the model on a cluster of shared memory computers with OpenMP and MPI hybrid programming, and a simulation algorithm that links cellular activity with the ECG. Results We demonstrate that electrical activities at channel, cell, and organ levels can be traced and captured conveniently in our extended cellular automaton system. Examples of some ECG waveforms simulated with a 2-D slice are given to support the ECG simulation algorithm. A performance evaluation of the 3-D model on a four-node cluster is also given. Conclusions Quantitative multicellular modeling with extended cellular automata is a highly efficient and widely applicable method to weave experimental data at different levels into computational models. This process can be used to investigate complex and collective biological activities that can be described neither by their governing differentiation equations nor by discrete parallel computation. Transparent cluster computing is a convenient and effective method to make time-consuming simulation feasible. Arrhythmias, as a typical case, can be effectively simulated with the methods

  16. MATtrack: A MATLAB-Based Quantitative Image Analysis Platform for Investigating Real-Time Photo-Converted Fluorescent Signals in Live Cells.

    Science.gov (United States)

    Courtney, Jane; Woods, Elena; Scholz, Dimitri; Hall, William W; Gautier, Virginie W

    2015-01-01

    We introduce here MATtrack, an open source MATLAB-based computational platform developed to process multi-Tiff files produced by a photo-conversion time lapse protocol for live cell fluorescent microscopy. MATtrack automatically performs a series of steps required for image processing, including extraction and import of numerical values from Multi-Tiff files, red/green image classification using gating parameters, noise filtering, background extraction, contrast stretching and temporal smoothing. MATtrack also integrates a series of algorithms for quantitative image analysis enabling the construction of mean and standard deviation images, clustering and classification of subcellular regions and injection point approximation. In addition, MATtrack features a simple user interface, which enables monitoring of Fluorescent Signal Intensity in multiple Regions of Interest, over time. The latter encapsulates a region growing method to automatically delineate the contours of Regions of Interest selected by the user, and performs background and regional Average Fluorescence Tracking, and automatic plotting. Finally, MATtrack computes convenient visualization and exploration tools including a migration map, which provides an overview of the protein intracellular trajectories and accumulation areas. In conclusion, MATtrack is an open source MATLAB-based software package tailored to facilitate the analysis and visualization of large data files derived from real-time live cell fluorescent microscopy using photoconvertible proteins. It is flexible, user friendly, compatible with Windows, Mac, and Linux, and a wide range of data acquisition software. MATtrack is freely available for download at eleceng.dit.ie/courtney/MATtrack.zip.

  17. [Quantitative analysis of drug expenditures variability in dermatology units].

    Science.gov (United States)

    Moreno-Ramírez, David; Ferrándiz, Lara; Ramírez-Soto, Gabriel; Muñoyerro, M Dolores

    2013-01-01

    Variability in adjusted drug expenditures among clinical departments raises the possibility of difficult access to certain therapies at the time that avoidable expenditures may also exist. Nevertheless, drug expenditures are not usually applied to clinical practice variability analysis. To identify and quantify variability in drug expenditures in comparable dermatology department of the Servicio Andaluz de Salud. Comparative economic analysis regarding the drug expenditures adjusted to population and health care production in 18 dermatology departments of the Servicio Andaluz de Salud. The 2012 cost and production data (homogeneous production units -HPU-)were provided by Inforcoan, the cost accounting information system of the Servicio Andaluz de Salud. The observed drug expenditure ratio ranged from 0.97?/inh to 8.90?/inh and from 208.45?/HPU to 1,471.95?/ HPU. The Pearson correlation between drug expenditure and population was 0.25 and 0.35 for the correlation between expenditure and homogeneous production (p=0.32 and p=0,15, respectively), both Pearson coefficients confirming the lack of correlation and arelevant degree of variability in drug expenditures. The quantitative analysis of variability performed through Pearson correlation has confirmed the existence of drug expenditure variability among comparable dermatology departments. Copyright © 2013 SEFH. Published by AULA MEDICA. All rights reserved.

  18. Problems with the quantitative spectroscopic analysis of oxygen rich Czech coals

    Energy Technology Data Exchange (ETDEWEB)

    Pavlikova, H.; Machovic, V.; Cerny, J. [Inst. of Chemical Technology, Prague (Czechoslovakia); Sebestova, E. [Inst. of Rock Structure and Mechanics, Prague (Czechoslovakia)

    1995-12-01

    Solid state NMR and FTIR spectroscopies are two main methods used for the structural analysis of coals and their various products. Obtaining quantitative parameters from coals, such as arornaticity (f{sub a}) by the above mentioned methods can be a rather difficult task. Coal samples of various rank were chosen for the quantitative NMR, FTIR and EPR analyses. The aromaticity was obtained by the FTIR, {sup 13}C CP/MAS and SP/MAS NMR experiments. The content of radicals and saturation characteristics of coals were measured by EPR spectroscopy. The following problems have been discussed: 1. The relationship between the amount of free radicals (N{sub g}) and f{sub a} by NMR. 2. The f{sub a} obtained by solid state NMR and FTIR spectroscopies. 3. The differences between the f{sub a} measured by CP and SP/NMR experiments. 4. The relationship between the content of oxygen groups and the saturation responses of coals. The reliability of our results was checked by measuring the structural parameters of Argonne premium coals.

  19. Quantitative EEG analysis in minimally conscious state patients during postural changes.

    Science.gov (United States)

    Greco, A; Carboncini, M C; Virgillito, A; Lanata, A; Valenza, G; Scilingo, E P

    2013-01-01

    Mobilization and postural changes of patients with cognitive impairment are standard clinical practices useful for both psychic and physical rehabilitation process. During this process, several physiological signals, such as Electroen-cephalogram (EEG), Electrocardiogram (ECG), Photopletysmography (PPG), Respiration activity (RESP), Electrodermal activity (EDA), are monitored and processed. In this paper we investigated how quantitative EEG (qEEG) changes with postural modifications in minimally conscious state patients. This study is quite novel and no similar experimental data can be found in the current literature, therefore, although results are very encouraging, a quantitative analysis of the cortical area activated in such postural changes still needs to be deeply investigated. More specifically, this paper shows EEG power spectra and brain symmetry index modifications during a verticalization procedure, from 0 to 60 degrees, of three patients in Minimally Consciousness State (MCS) with focused region of impairment. Experimental results show a significant increase of the power in β band (12 - 30 Hz), commonly associated to human alertness process, thus suggesting that mobilization and postural changes can have beneficial effects in MCS patients.

  20. Coupling Reagent for UV/vis Absorbing Azobenzene-Based Quantitative Analysis of the Extent of Functional Group Immobilization on Silica.

    Science.gov (United States)

    Choi, Ra-Young; Lee, Chang-Hee; Jun, Chul-Ho

    2018-05-18

    A methallylsilane coupling reagent, containing both a N-hydroxysuccinimidyl(NHS)-ester group and a UV/vis absorbing azobenzene linker undergoes acid-catalyzed immobilization on silica. Analysis of the UV/vis absorption band associated with the azobenzene group in the adduct enables facile quantitative determination of the extent of loading of the NHS groups. Reaction of NHS-groups on the silica surface with amine groups of GOx and rhodamine can be employed to generate enzyme or dye-immobilized silica for quantitative analysis.

  1. Adherence to HAART: a systematic review of developed and developing nation patient-reported barriers and facilitators.

    Directory of Open Access Journals (Sweden)

    Edward J Mills

    2006-11-01

    Full Text Available Adherence to highly active antiretroviral therapy (HAART medication is the greatest patient-enabled predictor of treatment success and mortality for those who have access to drugs. We systematically reviewed the literature to determine patient-reported barriers and facilitators to adhering to antiretroviral therapy.We examined both developed and developing nations. We searched the following databases: AMED (inception to June 2005, Campbell Collaboration (inception to June 2005, CinAhl (inception to June 2005, Cochrane Library (inception to June 2005, Embase (inception to June 2005, ERIC (inception to June 2005, MedLine (inception to June 2005, and NHS EED (inception to June 2005. We retrieved studies conducted in both developed and developing nation settings that examined barriers and facilitators addressing adherence. Both qualitative and quantitative studies were included. We independently, in duplicate, extracted data reported in qualitative studies addressing adherence. We then examined all quantitative studies addressing barriers and facilitators noted from the qualitative studies. In order to place the findings of the qualitative studies in a generalizable context, we meta-analyzed the surveys to determine a best estimate of the overall prevalence of issues. We included 37 qualitative studies and 47 studies using a quantitative methodology (surveys. Seventy-two studies (35 qualitative were conducted in developed nations, while the remaining 12 (two qualitative were conducted in developing nations. Important barriers reported in both economic settings included fear of disclosure, concomitant substance abuse, forgetfulness, suspicions of treatment, regimens that are too complicated, number of pills required, decreased quality of life, work and family responsibilities, falling asleep, and access to medication. Important facilitators reported by patients in developed nation settings included having a sense of self-worth, seeing positive

  2. Quantitative risk analysis of urban flooding in lowland areas

    NARCIS (Netherlands)

    Ten Veldhuis, J.A.E.

    2010-01-01

    Urban flood risk analyses suffer from a lack of quantitative historical data on flooding incidents. Data collection takes place on an ad hoc basis and is usually restricted to severe events. The resulting data deficiency renders quantitative assessment of urban flood risks uncertain. The study

  3. High-performance hybrid Orbitrap mass spectrometers for quantitative proteome analysis

    DEFF Research Database (Denmark)

    Williamson, James C; Edwards, Alistair V G; Verano-Braga, Thiago

    2016-01-01

    We present basic workups and quantitative comparisons for two current generation Orbitrap mass spectrometers, the Q Exactive Plus and Orbitrap Fusion Tribrid, which are widely considered two of the highest performing instruments on the market. We assessed the performance of two quantitative methods...... on both instruments, namely label-free quantitation and stable isotope labeling using isobaric tags, for studying the heat shock response in Escherichia coli. We investigated the recently reported MS3 method on the Fusion instrument and the potential of MS3-based reporter ion isolation Synchronous...... Precursor Selection (SPS) and its impact on quantitative accuracy. We confirm that the label-free approach offers a more linear response with a wider dynamic range than MS/MS-based isobaric tag quantitation and that the MS3/SPS approach alleviates but does not eliminate dynamic range compression. We...

  4. Facilitators and barriers to quality of care in maternal, newborn and child health: a global situational analysis through metareview.

    Science.gov (United States)

    Nair, Manisha; Yoshida, Sachiyo; Lambrechts, Thierry; Boschi-Pinto, Cynthia; Bose, Krishna; Mason, Elizabeth Mary; Mathai, Matthews

    2014-05-22

    Conduct a global situational analysis to identify the current facilitators and barriers to improving quality of care (QoC) for pregnant women, newborns and children. Metareview of published and unpublished systematic reviews and meta-analyses conducted between January 2000 and March 2013 in any language. Assessment of Multiple Systematic Reviews (AMSTAR) is used to assess the methodological quality of systematic reviews. Health systems of all countries. Study outcome: QoC measured using surrogate indicators--effective, efficient, accessible, acceptable/patient centred, equitable and safe. Conducted in two phases (1) qualitative synthesis of extracted data to identify and group the facilitators and barriers to improving QoC, for each of the three population groups, into the six domains of WHO's framework and explore new domains and (2) an analysis grid to map the common facilitators and barriers. We included 98 systematic reviews with 110 interventions to improve QoC from countries globally. The facilitators and barriers identified fitted the six domains of WHO's framework--information, patient-population engagement, leadership, regulations and standards, organisational capacity and models of care. Two new domains, 'communication' and 'satisfaction', were generated. Facilitators included active and regular interpersonal communication between users and providers; respect, confidentiality, comfort and support during care provision; engaging users in decision-making; continuity of care and effective audit and feedback mechanisms. Key barriers identified were language barriers in information and communication; power difference between users and providers; health systems not accounting for user satisfaction; variable standards of implementation of standard guidelines; shortage of resources in health facilities and lack of studies assessing the role of leadership in improving QoC. These were common across the three population groups. The barriers to good

  5. Pancreaticobiliary duct changes of periampullary carcinomas: Quantitative analysis at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Dong Sheng, E-mail: victoryhope@163.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Department of Radiology, No.4 West China Teaching Hospital of Sichuan University, Chengdu 610041 (China); Chen, Wei Xia, E-mail: wxchen25@126.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Wang, Xiao Dong, E-mail: tyfs03yz@163.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Acharya, Riwaz, E-mail: riwaz007@hotmail.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Jiang, Xing Hua, E-mail: 13881865517@163.com [Department of Pathology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China)

    2012-09-15

    Purpose: To quantitatively analyse the pancreaticobiliary duct changes of periampullary carcinomas with volumetric interpolated breath-hold examination (VIBE) and true fast imaging with steady-state precession (true FISP) sequence, and investigate the value of these findings in differentiation and preoperative evaluation. Materials and methods: Magnetic resonance (MR) images of 71 cases of periampullary carcinomas (34 cases of pancreatic head carcinoma, 16 cases of intrapancreatic bile duct carcinoma and 21 cases of ampullary carcinoma) confirmed histopathologically were analysed. The maximum diameter of the common bile duct (CBD) and main pancreatic duct (MPD), dilated pancreaticobiliary duct angle and the distance from the end of the proximal dilated pancreaticobiliary duct to the major papilla were measured. Analysis of variance and the Chi-squared test were performed. Results: These findings showed significant differences among the three subtypes: the distance from the end of proximal dilated pancreaticobiliary duct to the major papilla and pancreaticobiliary duct angle. The distance and the pancreaticobiliary duct angle were least for ampullary carcinoma among the three subtypes. The percentage of dilated CBD was 94.1%, 93.8%, and 100% for pancreatic head carcinoma, intrapancreatic bile duct carcinoma and ampullary carcinoma, respectively. And that for the dilated MPD was 58.8%, 43.8%, and 42.9%, respectively. Conclusion: Quantitative analysis of the pancreaticobiliary ductal system can provide accurate and objective assessment of the pancreaticobiliary duct changes. Although benefit in differential diagnosis is limited, these findings are valuable in preoperative evaluation for both radical resection and palliative surgery.

  6. QUANTITATIVE EEG COMPARATIVE ANALYSIS BETWEEN AUTISM SPECTRUM DISORDER (ASD AND ATTENTION DEFICIT HYPERACTIVITY DISORDER (ADHD

    Directory of Open Access Journals (Sweden)

    Plamen D. Dimitrov

    2017-01-01

    Full Text Available Background: Autism is a mental developmental disorder, manifested in the early childhood. Attention deficit hyperactivity disorder is another psychiatric condition of the neurodevelopmental type. Both disorders affect information processing in the nervous system, altering the mechanisms which control how neurons and their synapses are connected and organized. Purpose: To examine if quantitative EEG assessment is sensitive and simple enough to differentiate autism from attention deficit hyperactivity disorder and neurologically typical children. Material and methods: Quantitative EEG is a type of electrophysiological assessment that uses computerized mathematical analysis to convert the raw waveform data into different frequency ranges. Each frequency range is averaged across a sample of data and quantified into mean amplitude (voltage in microvolts mV. We performed quantitative EEG analysis and compared 4 cohorts of children (aged from 3 to 7 years: with autism (high [n=27] and low [n=52] functioning, with attention deficit hyperactivity disorder [n=34], and with typical behavior [n75]. Results: Our preliminary results show that there are significant qEEG differences between the groups of patients and the control cohort. The changes affect the potential levels of delta-, theta-, alpha-, and beta- frequency spectrums. Conclusion: The present study shows some significant quantitative EEG findings in autistic patients. This is a step forward in our efforts, aimed at defining specific neurophysiologic changes, in order to develop and refine strategies for early diagnosis of autism spectrum disorders, differentiation from other development conditions in childhood, detection of specific biomarkers and early initiation of treatment.

  7. YBYRÁ facilitates comparison of large phylogenetic trees.

    Science.gov (United States)

    Machado, Denis Jacob

    2015-07-01

    The number and size of tree topologies that are being compared by phylogenetic systematists is increasing due to technological advancements in high-throughput DNA sequencing. However, we still lack tools to facilitate comparison among phylogenetic trees with a large number of terminals. The "YBYRÁ" project integrates software solutions for data analysis in phylogenetics. It comprises tools for (1) topological distance calculation based on the number of shared splits or clades, (2) sensitivity analysis and automatic generation of sensitivity plots and (3) clade diagnoses based on different categories of synapomorphies. YBYRÁ also provides (4) an original framework to facilitate the search for potential rogue taxa based on how much they affect average matching split distances (using MSdist). YBYRÁ facilitates comparison of large phylogenetic trees and outperforms competing software in terms of usability and time efficiency, specially for large data sets. The programs that comprises this toolkit are written in Python, hence they do not require installation and have minimum dependencies. The entire project is available under an open-source licence at http://www.ib.usp.br/grant/anfibios/researchSoftware.html .

  8. Multivariate quantitative structure-pharmacokinetic relationships (QSPKR) analysis of adenosine A(1) receptor agonists in rat

    NARCIS (Netherlands)

    Van der Graaf, PH; Nilsson, J; Van Schaick, EA; Danhof, M

    The aim of this study was to investigate the feasibility of a quantitative structure-pharmacokinetic relationships (QSPKR) method based on contemporary three-dimensional (3D) molecular characterization and multivariate statistical analysis. For this purpose, the programs SYBYL/CoMFA, GRID, and

  9. Quantitative Analysis of Thallium-201 Myocardial Tomograms

    International Nuclear Information System (INIS)

    Kim, Sang Eun; Nam, Gi Byung; Choi, Chang Woon

    1991-01-01

    The purpose of this study was to assess the ability of quantitative Tl-201 tomography to identify and localize coronary artery disease (CAD). The study population consisted of 41 patients (31 males, 10 females; mean age 55 ± 7 yr) including 14 with prior myocardial infarction who underwent both exercise Tl-201 myocardium SPECT and coronary angiography for the evaluation of chest pain. From the short axis and vertical long axis tomograms, stress extent polar maps were generated by Cedars-Sinai Medical Center program, and the 9 stress defect extent (SDE) was quantified for each coronary artery territory. For the purpose of this study, the coronary circulation was divided into 6 arterial segments, and the myocardial ischemic score (MIS) was calculated from the coronary angiogram. Sensitivity for the detection of CAD (>50% coronary stenosis by angiography) by stress extent polar map was 95% in single vessel disease, and 100% in double and triple vessel diseases. Overall sensitivity was 97%<. Sensitivity and specificity for the detection of individual diseased vessels were, respectively, 87% and 90% for the left anterior descending artery (LAD), 36% and 93% for the left circumflex artery (LCX), and 71% and 70%, for the right coronary artery (RCA). Concordance for the detection of individual diseased vessels between the coronary angiography and stress polar map was fair for the LAD (kappa=0.70), and RCA (kappa=0.41) lesions, whereas it was poor for the LCK lesions (kappa =0.32) There were significant correlations between the MIS and SDE in LAD (rs=0. 56, p=0.0027), and RCA territory (rs=0.60, p=0.0094). No significant correlation was found in LCX territory. When total vascular territories were combined, there was a significant correlation between the MIS and SDE (rs=0.42, p=0,0116). In conclusion, the quantitative analysis of Tl-201 tomograms appears to be accurate for determining the presence and location of CAD.

  10. Qualitative and quantitative methods for human factor analysis and assessment in NPP. Investigations and results

    International Nuclear Information System (INIS)

    Hristova, R.; Kalchev, B.; Atanasov, D.

    2005-01-01

    We consider here two basic groups of methods for analysis and assessment of the human factor in the NPP area and give some results from performed analyses as well. The human factor is the human interaction with the design equipment, with the working environment and takes into account the human capabilities and limits. In the frame of the qualitative methods for analysis of the human factor are considered concepts and structural methods for classifying of the information, connected with the human factor. Emphasize is given to the HPES method for human factor analysis in NPP. Methods for quantitative assessment of the human reliability are considered. These methods allow assigning of probabilities to the elements of the already structured information about human performance. This part includes overview of classical methods for human reliability assessment (HRA, THERP), and methods taking into account specific information about human capabilities and limits and about the man-machine interface (CHR, HEART, ATHEANA). Quantitative and qualitative results concerning human factor influence in the initiating events occurrences in the Kozloduy NPP are presented. (authors)

  11. Hair analysis in toxicological investigation of drug-facilitated crimes in Denmark over a 8-year period

    DEFF Research Database (Denmark)

    Wang, Xin; Johansen, Sys Stybe; Nielsen, Marie Katrine Klose

    2018-01-01

    analgesics, antipsychotics, barbiturates, and illicit drugs from DFC cases. Drug detection in hair in DFC cases following a single or few intakes of chlorprothixene, codeine, diphenhydramine, oxazepam, oxycodone, promethazine, and phenobarbital is reported for the first time in forensic toxicology......Hair can serve as a specimen for identifying past drug exposure. Segmental hair analysis may differentiate a single exposure from chronic use. Consequently, segmental hair analysis is useful for disclosing a single drug ingestion, as well as for determining repeated exposures in drug......-facilitated crimes (DFCs). This paper presents an overview of toxicological investigations that have used hair analysis in DFC cases from 2009 to 2016 in Denmark. Hair concentrations were determined for 24 DFC-related drugs and metabolites, including benzodiazepines and other hypnotics, antihistamines, opioid...

  12. Quantitative analysis of tritium distribution in austenitic stainless steels welds

    International Nuclear Information System (INIS)

    Roustila, A.; Kuromoto, N.; Brass, A.M.; Chene, J.

    1994-01-01

    Tritium autoradiography was used to study the tritium distribution in laser and arc (TIG) weldments performed on tritiated AISI 316 samples. Quantitative values of the local tritium concentration were obtained from the microdensitometric analysis of the autoradiographs. This procedure was used to map the tritium concentration in the samples before and after laser and TIG treatments. The effect of the detritiation conditions and of welding on the tritium distribution in the material is extensively characterized. The results illustrate the interest of the technique for predicting a possible embrittlement of the material associated with a local enhancement of the tritium concentration and the presence of helium 3 generated by tritium decay. ((orig.))

  13. Label free quantitative proteomics analysis on the cisplatin resistance in ovarian cancer cells.

    Science.gov (United States)

    Wang, F; Zhu, Y; Fang, S; Li, S; Liu, S

    2017-05-20

    Quantitative proteomics has been made great progress in recent years. Label free quantitative proteomics analysis based on the mass spectrometry is widely used. Using this technique, we determined the differentially expressed proteins in the cisplatin-sensitive ovarian cancer cells COC1 and cisplatin-resistant cells COC1/DDP before and after the application of cisplatin. Using the GO analysis, we classified those proteins into different subgroups bases on their cellular component, biological process, and molecular function. We also used KEGG pathway analysis to determine the key signal pathways that those proteins were involved in. There are 710 differential proteins between COC1 and COC1/DDP cells, 783 between COC1 and COC1/DDP cells treated with cisplatin, 917 between the COC1/DDP cells and COC1/DDP cells treated with LaCl3, 775 between COC1/DDP cells treated with cisplatin and COC1/DDP cells treated with cisplatin and LaCl3. Among the same 411 differentially expressed proteins in cisplatin-sensitive COC1 cells and cisplain-resistant COC1/DDP cells before and after cisplatin treatment, 14% of them were localized on the cell membrane. According to the KEGG results, differentially expressed proteins were classified into 21 groups. The most abundant proteins were involved in spliceosome. This study lays a foundation for deciphering the mechanism for drug resistance in ovarian tumor.

  14. A new technique for quantitative analysis of hair loss in mice using grayscale analysis.

    Science.gov (United States)

    Ponnapakkam, Tulasi; Katikaneni, Ranjitha; Gulati, Rohan; Gensure, Robert

    2015-03-09

    Alopecia is a common form of hair loss which can occur in many different conditions, including male-pattern hair loss, polycystic ovarian syndrome, and alopecia areata. Alopecia can also occur as a side effect of chemotherapy in cancer patients. In this study, our goal was to develop a consistent and reliable method to quantify hair loss in mice, which will allow investigators to accurately assess and compare new therapeutic approaches for these various forms of alopecia. The method utilizes a standard gel imager to obtain and process images of mice, measuring the light absorption, which occurs in rough proportion to the amount of black (or gray) hair on the mouse. Data that has been quantified in this fashion can then be analyzed using standard statistical techniques (i.e., ANOVA, T-test). This methodology was tested in mouse models of chemotherapy-induced alopecia, alopecia areata and alopecia from waxing. In this report, the detailed protocol is presented for performing these measurements, including validation data from C57BL/6 and C3H/HeJ strains of mice. This new technique offers a number of advantages, including relative simplicity of application, reliance on equipment which is readily available in most research laboratories, and applying an objective, quantitative assessment which is more robust than subjective evaluations. Improvements in quantification of hair growth in mice will improve study of alopecia models and facilitate evaluation of promising new therapies in preclinical studies.

  15. Relative Quantitative Proteomic Analysis of Brucella abortus Reveals Metabolic Adaptation to Multiple Environmental Stresses.

    Science.gov (United States)

    Zai, Xiaodong; Yang, Qiaoling; Yin, Ying; Li, Ruihua; Qian, Mengying; Zhao, Taoran; Li, Yaohui; Zhang, Jun; Fu, Ling; Xu, Junjie; Chen, Wei

    2017-01-01

    Brucella spp. are facultative intracellular pathogens that cause chronic brucellosis in humans and animals. The virulence of Brucella primarily depends on its successful survival and replication in host cells. During invasion of the host tissue, Brucella is simultaneously subjected to a variety of harsh conditions, including nutrient limitation, low pH, antimicrobial defenses, and extreme levels of reactive oxygen species (ROS) via the host immune response. This suggests that Brucella may be able to regulate its metabolic adaptation in response to the distinct stresses encountered during its intracellular infection of the host. An investigation into the differential proteome expression patterns of Brucella grown under the relevant stress conditions may contribute toward a better understanding of its pathogenesis and adaptive response. Here, we utilized a mass spectrometry-based label-free relative quantitative proteomics approach to investigate and compare global proteomic changes in B. abortus in response to eight different stress treatments. The 3 h short-term in vitro single-stress and multi-stress conditions mimicked the in vivo conditions of B. abortus under intracellular infection, with survival rates ranging from 3.17 to 73.17%. The proteomic analysis identified and quantified a total of 2,272 proteins and 74% of the theoretical proteome, thereby providing wide coverage of the B. abortus proteome. By including eight distinct growth conditions and comparing these with a control condition, we identified a total of 1,221 differentially expressed proteins (DEPs) that were significantly changed under the stress treatments. Pathway analysis revealed that most of the proteins were involved in oxidative phosphorylation, ABC transporters, two-component systems, biosynthesis of secondary metabolites, the citrate cycle, thiamine metabolism, and nitrogen metabolism; constituting major response mechanisms toward the reconstruction of cellular homeostasis and metabolic

  16. Quantitative Outline-based Shape Analysis and Classification of Planetary Craterforms using Supervised Learning Models

    Science.gov (United States)

    Slezak, Thomas Joseph; Radebaugh, Jani; Christiansen, Eric

    2017-10-01

    The shapes of craterform morphology on planetary surfaces provides rich information about their origins and evolution. While morphologic information provides rich visual clues to geologic processes and properties, the ability to quantitatively communicate this information is less easily accomplished. This study examines the morphology of craterforms using the quantitative outline-based shape methods of geometric morphometrics, commonly used in biology and paleontology. We examine and compare landforms on planetary surfaces using shape, a property of morphology that is invariant to translation, rotation, and size. We quantify the shapes of paterae on Io, martian calderas, terrestrial basaltic shield calderas, terrestrial ash-flow calderas, and lunar impact craters using elliptic Fourier analysis (EFA) and the Zahn and Roskies (Z-R) shape function, or tangent angle approach to produce multivariate shape descriptors. These shape descriptors are subjected to multivariate statistical analysis including canonical variate analysis (CVA), a multiple-comparison variant of discriminant analysis, to investigate the link between craterform shape and classification. Paterae on Io are most similar in shape to terrestrial ash-flow calderas and the shapes of terrestrial basaltic shield volcanoes are most similar to martian calderas. The shapes of lunar impact craters, including simple, transitional, and complex morphology, are classified with a 100% rate of success in all models. Multiple CVA models effectively predict and classify different craterforms using shape-based identification and demonstrate significant potential for use in the analysis of planetary surfaces.

  17. Porosity determination on pyrocarbon by means of automatic quantitative image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koizlik, K.; Uhlenbruck, U.; Delle, W.; Hoven, H.; Nickel, H.

    1976-05-01

    For a long time, the quantitative image analysis is well known as a method for quantifying the results of material investigation basing on ceramography. The development of the automatic image analyzers has made it a fast and elegant procedure for evaluation. Since 1975, it is used in IRW to determine easily and routinely the macroporosity and by this the density of the pyrocarbon coatings of nuclear fuel particles. This report describes the definition of measuring parameters, the measuring procedure, the mathematical calculations, and first experimental and mathematical results.

  18. Computer-assisted sequential quantitative analysis of gallium scans in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Rohatgi, P.K.; Bates, H.R.; Noss, R.W.

    1985-01-01

    Fifty-one sequential gallium citrate scans were performed in 22 patients with biopsy-proven sarcoidosis. A computer-assisted quantitative analysis of these scans was performed to obtain a gallium score. The changes in gallium score were correlated with changes in serum angiotensin converting enzyme (SACE) activity and objective changes in clinical status. There was a good concordance between changes in gallium score, SACE activity and clinical assessment in patients with sarcoidosis, and changes in gallium index were slightly superior to SACE index in assessing activity of sarcoidosis. (author)

  19. An approach for quantitative image quality analysis for CT

    Science.gov (United States)

    Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe

    2016-03-01

    An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.

  20. RFLP-facilitated investigation of the quantitative resistance of rice to brown planthopper ( Nilaparvata lugens).

    Science.gov (United States)

    Xu, X. F.; Mei, H. W.; Luo, L. J.; Cheng, X. N.; Li, Z. K.

    2002-02-01

    Quantitative trait loci (QTLs), conferring quantitative resistance to rice brown planthopper (BPH), were investigated using 160 F(11) recombinant inbred lines (RILs) from the Lemont/Teqing cross, a complete RFLP map, and replicated phenotyping of seedbox inoculation. The paternal indica parent, Teqing, was more-resistant to BPH than the maternal japonica parent, Lemont. The RILs showed transgressive segregation for resistance to BPH. Seven main-effect QTLs and many epistatic QTL pairs were identified and mapped on the 12 rice chromosomes. Collectively, the main-effect and epistatic QTLs accounted for over 70% of the total variation in damage scores. Teqing has the resistance allele at four main-effect QTLs, and the Lemont allele resulted in resistance at the other three. Of the main-effect QTLs identified, QBphr5b was mapped to the vicinity of gl1, a major gene controlling leaf and stem pubescence. The Teqing allele controlling leaf and stem pubescence was associated with resistance, while the Lemont allele for glabrous stem and leaves was associated with susceptibility, indicating that this gene may have contributed to resistance through antixenosis. Similar to the reported BPH resistance genes, the other six detected main-effect QTLs were all mapped to regions where major disease resistance genes locate, suggesting they might have contributed either to antibiosis or tolerance. Our results indicated that marker-aided pyramiding of major resistance genes and QTLs should provide effective and stable control over this devastating pest.