WorldWideScience

Sample records for eyes open eo

  1. With eyes wide open

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth; Pedersen, Chistina Hee

    2013-01-01

    and that vulnerability and discomfort are often overlooked as transformative forces. The analysis draws on data from a classroom context in which university students tested methods for facilitating creative thinking in a course on data production and creativity. The data stem from a session on the method “Lego Serious...... in constructions of group identity when an external facilitator disrupts a context. We argue that the facilitation of creative methods calls for keeping our eyes wide open for tensions, for they are the mulch that improves the soil....

  2. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  3. Directionality of large-scale resting-state brain networks during eyes open and eyes closed conditions

    NARCIS (Netherlands)

    Zhang, Delong; Liang, Bishan; Wu, Xia; Wang, Zengjian; Xu, Pengfei; Chang, Song; Liu, Bo; Liu, Ming; Huang, Ruiwang

    2015-01-01

    The present study examined directional connections in the brain among resting-state networks (RSNs) when the participant had their eyes open (E0) or had their eyes closed (EC). The resting state fMRI data were collected from 20 healthy participants (9 males, 20.17 +/- 2.74 years) under the EO and EC

  4. Open your eyes and vote!

    CERN Multimedia

    Rebecca Leam

    The CERN film-making club is organizing the second edition of the CinéGlobe International Short Film Festival and everyone is invited to attend a series of selection screenings in November to vote on which they like and think should be publicly shown in the Globe and at the Forum Meyrin in February 2010.   This year over 700 short films were submitted for three competitions: the majority for the general fiction category for films up to ten minutes in length, and others for science fiction (20 minutes) and science documentary (30 minutes). “In 2007 we had just one competition open to films from any genre. We decided to add the science related competitions to the second edition to make a stronger link with CERN as a physics lab,” explained Quentin King, Chairman of the Selection Committee and member of CERN’s film-making club, Open Your Eyes Films. “The entries are extremely diverse and touch on almost every aspect of life. The creativity of short...

  5. Maximizing the use of EO products: how to leverage the potential of open geospatial service architectures

    Science.gov (United States)

    Usländer, Thomas

    2012-10-01

    The demand for the rapid provision of EO products with well-defined characteristics in terms of temporal, spatial, image-specific and thematic criteria is increasing. Examples are products to support near real-time damage assessment after a natural disaster event, e.g. an earthquake. However, beyond the organizational and economic questions, there are technological and systemic barriers to enable a comfortable search, order, delivery or even combination of EO products. Most portals of space agencies and EO product providers require sophisticated satellite and product knowledge and, even worse, are all different and not interoperable. This paper gives an overview about the use cases and the architectural solutions that aim at an open and flexible EO mission infrastructure with application-oriented user interfaces and well-defined service interfaces based upon open standards. It presents corresponding international initiatives such as INSPIRE (Infrastructure for Spatial Information in the European Community), GMES (Global Monitoring for Environment and Security), GEOSS (Global Earth Observation System of Systems) and HMA (Heterogeneous Missions Accessibility) and their associated infrastructure approaches. The paper presents a corresponding analysis and design methodology and two examples how such architectures are already successfully used in early warning systems for geo-hazards and toolsets for environmentallyinduced health risks. Finally, the paper concludes with an outlook how these ideas relate to the vision of the Future Internet.

  6. Frequency-Dependent Modulation of Regional Synchrony in the Human Brain by Eyes Open and Eyes Closed Resting-States.

    Science.gov (United States)

    Song, Xiaopeng; Zhou, Shuqin; Zhang, Yi; Liu, Yijun; Zhu, Huaiqiu; Gao, Jia-Hong

    2015-01-01

    The eyes-open (EO) and eyes-closed (EC) states have differential effects on BOLD-fMRI signal dynamics, affecting both the BOLD oscillation frequency of a single voxel and the regional homogeneity (ReHo) of several neighboring voxels. To explore how the two resting-states modulate the local synchrony through different frequency bands, we decomposed the time series of each voxel into several components that fell into distinct frequency bands. The ReHo in each of the bands was calculated and compared between the EO and EC conditions. The cross-voxel correlations between the mean frequency and the overall ReHo of each voxel's original BOLD series in different brain areas were also calculated and compared between the two states. Compared with the EC state, ReHo decreased with EO in a wide frequency band of 0.01-0.25 Hz in the bilateral thalamus, sensorimotor network, and superior temporal gyrus, while ReHo increased significantly in the band of 0-0.01 Hz in the primary visual cortex, and in a higher frequency band of 0.02-0.1 Hz in the higher order visual areas. The cross-voxel correlations between the frequency and overall ReHo were negative in all the brain areas but varied from region to region. These correlations were stronger with EO in the visual network and the default mode network. Our results suggested that different frequency bands of ReHo showed different sensitivity to the modulation of EO-EC states. The better spatial consistency between the frequency and overall ReHo maps indicated that the brain might adopt a stricter frequency-dependent configuration with EO than with EC.

  7. EYE TRAUMA. OPEN GLOBE INJURY MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Mojca Globočnik Petrovič

    2004-05-01

    Full Text Available Background. Ocular trauma is important cause of blindness. Birmingham Eye Trauma Terminology allows us to use a standardized eye injury terminology which permits an unambigous interpretation. The Eye Injury Registry enables the analysis of medical, epidemyologic and social data.The most frequent ocular injury ocular contusion has a relatively good prognosis. An adequate primary ocular repair and correct timing of pars plana vitrectomy are very important in open globe injury management. There still exist some controversial issues concerning the role of posterior segment surgery in open globe injuries. These include timing of surgery, prophylactic scleral buckle placement and a proper use of systemic and intravitreal antibiotics.Conclusions. With adequate primary ocular repair, the use of systemic, intravitreal antibiotics, scleral buckling and proper timing for pars plana vitrectomy the prognosis for ocular trauma cases can be better.

  8. [Fatal air embolism during open eye surgery].

    Science.gov (United States)

    Dermigny, F; Daelman, F; Guinot, P-G; Hubert, V; Jezraoui, P; Thomas, F; Milazzo, S; Dupont, H

    2008-10-01

    Gas embolism is well known for a specific subset of surgical interventions. Prevention and early detection are the main objectives of the anesthetic and surgical team. However, it may exceptionally occur during eye surgery with dramatic outcomes. We report the case of a 51-year-old man, ASA physical status 1, who presented a cardiac arrest during an open eye surgery for the extraction of a foreign body with intraocular air injection. Multiple organ failure has not been improved by hyperbaric oxygen therapy and the outcome was fatal.

  9. EOS developments

    Science.gov (United States)

    Sindrilaru, Elvin A.; Peters, Andreas J.; Adde, Geoffray M.; Duellmann, Dirk

    2017-10-01

    CERN has been developing and operating EOS as a disk storage solution successfully for over 6 years. The CERN deployment provides 135 PB and stores 1.2 billion replicas distributed over two computer centres. Deployment includes four LHC instances, a shared instance for smaller experiments and since last year an instance for individual user data as well. The user instance represents the backbone of the CERNBOX service for file sharing. New use cases like synchronisation and sharing, the planned migration to reduce AFS usage at CERN and the continuous growth has brought EOS to new challenges. Recent developments include the integration and evaluation of various technologies to do the transition from a single active in-memory namespace to a scale-out implementation distributed over many meta-data servers. The new architecture aims to separate the data from the application logic and user interface code, thus providing flexibility and scalability to the namespace component. Another important goal is to provide EOS as a CERN-wide mounted filesystem with strong authentication making it a single storage repository accessible via various services and front- ends (/eos initiative). This required new developments in the security infrastructure of the EOS FUSE implementation. Furthermore, there were a series of improvements targeting the end-user experience like tighter consistency and latency optimisations. In collaboration with Seagate as Openlab partner, EOS has a complete integration of OpenKinetic object drive cluster as a high-throughput, high-availability, low-cost storage solution. This contribution will discuss these three main development projects and present new performance metrics.

  10. Brain spontaneous fluctuations in sensorimotor regions were directly related to eyes open and eyes closed: evidences from a machine learning approach

    Directory of Open Access Journals (Sweden)

    Bishan eLiang

    2014-08-01

    Full Text Available Previous studies have demonstrated that the difference between resting-state brain activations depends on whether the subject was eyes open (EO or eyes closed (EC. However, whether the spontaneous fluctuations are directly related to these two different resting states are still largely unclear. In the present study, we acquired resting-state functional magnetic resonance imaging data from 24 healthy subjects (11 males, 20.17 ± 2.74 years under the EO and EC states. The amplitude of the spontaneous brain activity in low-frequency band was subsequently investigated by using the metric of fractional amplitude of low frequency fluctuation (fALFF for each subject under each state. A support vector machine (SVM analysis was then applied to evaluate whether the category of resting states could be determined from the brain spontaneous fluctuations. We demonstrated that these two resting states could be decoded from the identified pattern of brain spontaneous fluctuations, predominantly based on fALFF in the sensorimotor module. Specifically, we observed prominent relationships between increased fALFF for EC and decreased fALFF for EO in sensorimotor regions. Overall, the present results indicate that a SVM performs well in the discrimination between the brain spontaneous fluctuations of distinct resting states and provide new insight into the neural substrate of the resting states during EC and EO.

  11. Impaired Saccadic Eye Movement in Primary Open-angle Glaucoma

    DEFF Research Database (Denmark)

    Lamirel, Cédric; Milea, Dan; Cochereau, Isabelle

    2013-01-01

    PURPOSE:: Our study aimed at investigating the extent to which saccadic eye movements are disrupted in patients with primary open-angle glaucoma (POAG). This approach followed upon the discovery of differences in the eye-movement behavior of POAG patients during the exploration of complex visual...

  12. Diagnostic Value of Eye Opening in Infantile Seizures

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2005-10-01

    Full Text Available The significance of eye opening and closure during paroxysmal events in infants was examined by a retrospective review of video electroencephalograms of 91 seizures recorded in 69 infants at the Epilepsy Center, Children’s Memorial Hospital, Chicago, IL.

  13. Eye-openers from XMM-Newton

    Science.gov (United States)

    2000-02-01

    The images were obtained between 19-25 January at the very start of the science payload commissioning process. The spacecraft viewed three regions of the sky: part of the Large Magellanic Cloud (LMC), the Hickson Cluster Group 16 (HCG-16), and the star HR 1099. These targets were chosen because they all present a variety of X-ray extended and point sources and are very interesting regions. The expanding cauldon in the Large Magellanic Cloud The Large Magellanic Cloud also known as the Nebula Major is about 20 thousand light years in diameter. Situated 160 thousand light years from Earth, it is one of two irregularly shaped galaxies that are easily seen with the naked eye in the southern hemisphere. These galaxies are satellites of the Milky Way and appear to be slowly spiralling into our own Galaxy. The first image obtained by the EPIC-PN X-ray cameras viewed the 30 Doradus region of the Large Magellanic Cloud. Also called the Tarantula Nebula, 30 Doradus is a cauldron of creation where exploding stars are releasing vast amounts of matter and where new stars are being born. The image presents the million degree temperatures of the emitting medium, with blue indicating the hottest regions; green intermediate temperatures and red the coldest regions. The white and blue arc-like formation just off the centre is a new object, only part of which was known in the past. It has the appearance of a supernova remnant with its expanding glowing-hot gas producing X-ray emission as it collides with the interstellar medium. On the lower right of the picture is the remains of a star that exploded as Supernova 1987A on 24 February 1987. It was the first supernova to reach naked-eye brightness since 1604 (Kepler's star) and remained visible to the naked eye for nearly nine months. The brightest source in the view, upper left, is another supernova remnant (N157D). Martin Turner, Principal Investigator for the EPIC cameras... "These first pictures are tremendously exciting after so

  14. Utilizing Free and Open Source Software to access, view and compare in situ observations, EO products and model output data

    Science.gov (United States)

    Vines, Aleksander; Hamre, Torill; Lygre, Kjetil

    2014-05-01

    The GreenSeas project (Development of global plankton data base and model system for eco-climate early warning) aims to advance the knowledge and predictive capacities of how marine ecosystems will respond to global change. A main task has been to set up a data delivery and monitoring core service following the open and free data access policy implemented in the Global Monitoring for the Environment and Security (GMES) programme. The aim is to ensure open and free access to historical plankton data, new data (EO products and in situ measurements), model data (including estimates of simulation error) and biological, environmental and climatic indicators to a range of stakeholders, such as scientists, policy makers and environmental managers. To this end, we have developed a geo-spatial database of both historical and new in situ physical, biological and chemical parameters for the Southern Ocean, Atlantic, Nordic Seas and the Arctic, and organized related satellite-derived quantities and model forecasts in a joint geo-spatial repository. For easy access to these data, we have implemented a web-based GIS (Geographical Information Systems) where observed, derived and forcasted parameters can be searched, displayed, compared and exported. Model forecasts can also be uploaded dynamically to the system, to allow modelers to quickly compare their results with available in situ and satellite observations. We have implemented the web-based GIS(Geographical Information Systems) system based on free and open source technologies: Thredds Data Server, ncWMS, GeoServer, OpenLayers, PostGIS, Liferay, Apache Tomcat, PRTree, NetCDF-Java, json-simple, Geotoolkit, Highcharts, GeoExt, MapFish, FileSaver, jQuery, jstree and qUnit. We also wanted to used open standards to communicate between the different services and we use WMS, WFS, netCDF, GML, OPeNDAP, JSON, and SLD. The main advantage we got from using FOSS was that we did not have to invent the wheel all over again, but could use

  15. Advantage of hyperspectral EO-1 Hyperion over multispectral IKONOS, GeoEye-1, WorldView-2, Landsat ETM+, and MODIS vegetation indices in crop biomass estimation

    Science.gov (United States)

    Marshall, Michael T.; Thenkabail, Prasad S.

    2015-01-01

    Crop biomass is increasingly being measured with surface reflectance data derived from multispectral broadband (MSBB) and hyperspectral narrowband (HNB) space-borne remotely sensed data to increase the accuracy and efficiency of crop yield models used in a wide array of agricultural applications. However, few studies compare the ability of MSBBs versus HNBs to capture crop biomass variability. Therefore, we used standard data mining techniques to identify a set of MSBB data from the IKONOS, GeoEye-1, Landsat ETM+, MODIS, WorldView-2 sensors and compared their performance with HNB data from the EO-1 Hyperion sensor in explaining crop biomass variability of four important field crops (rice, alfalfa, cotton, maize). The analysis employed two-band (ratio) vegetation indices (TBVIs) and multiband (additive) vegetation indices (MBVIs) derived from Singular Value Decomposition (SVD) and stepwise regression. Results demonstrated that HNB-derived TBVIs and MBVIs performed better than MSBB-derived TBVIs and MBVIs on a per crop basis and for the pooled data: overall, HNB TBVIs explained 5–31% greater variability when compared with various MSBB TBVIs; and HNB MBVIs explained 3–33% greater variability when compared with various MSBB MBVIs. The performance of MSBB MBVIs and TBVIs improved mildly, by combining spectral information across multiple sensors involving IKONOS, GeoEye-1, Landsat ETM+, MODIS, and WorldView-2. A number of HNBs that advance crop biomass modeling were determined. Based on the highest factor loadings on the first component of the SVD, the “red-edge” spectral range (700–740 nm) centered at 722 nm (bandwidth = 10 nm) stood out prominently, while five additional and distinct portions of the recorded spectral range (400–2500 nm) centered at 539 nm, 758 nm, 914 nm, 1130 nm, 1320 nm (bandwidth = 10 nm) were also important. The best HNB vegetation indices for crop biomass estimation involved 549 and 752 nm for rice (R2 = 0.91); 925 and 1104 nm for

  16. Radiometric Cross-Calibration of the Chilean Satellite FASat-C Using RapidEye and EO-1 Hyperion Data and a Simultaneous Nadir Overpass Approach

    Directory of Open Access Journals (Sweden)

    Carolina Barrientos

    2016-07-01

    Full Text Available The absolute radiometric calibration of a satellite sensor is the critical factor that ensures the usefulness of the acquired data for quantitative applications on remote sensing. This work presents the results of the first cross-calibration of the sensor on board the Sistema Satelital de Observación de la Tierra (SSOT Chilean satellite or Air Force Satellite FASat-C. RapidEye-MSI was chosen as the reference sensor, and a simultaneous Nadir Overpass Approach (SNO was applied. The biases caused by differences in the spectral responses of both instruments were compensated through an adjustment factor derived from EO-1 Hyperion data. Through this method, the variations affecting the radiometric response of New AstroSat Optical Modular Instrument (NAOMI-1, have been corrected based on collections over the Frenchman Flat calibration site. The results of a preliminary evaluation of the pre-flight and updated coefficients have shown a significant improvement in the accuracy of at-sensor radiances and TOA reflectances: an average agreement of 2.63% (RMSE was achieved for the multispectral bands of both instruments. This research will provide a basis for the continuity of calibration and validation tasks of future Chilean space missions.

  17. [Dry eye syndrome in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S

    2015-01-01

    to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.

  18. Normative values for the unipedal stance test with eyes open and closed.

    Science.gov (United States)

    Springer, Barbara A; Marin, Raul; Cyhan, Tamara; Roberts, Holly; Gill, Norman W

    2007-01-01

    Limited normative data are available for the unipedal stance test (UPST), making it difficult for clinicians to use it confidently to detect subtle balance impairments. The purpose of this study was to generate normative values for repeated trials of the UPST with eyes opened and eyes closed across age groups and gender. This prospective, mixed-model design was set in a tertiary care medical center. Healthy subjects (n= 549), 18 years or older, performed the UPST with eyes open and closed. Mean and best of 3 UPST times for males and females of 6 age groups (18-39, 40-49, 50-59, 60-69, 70-79, and 80+) were documented and inter-rater reliability was tested. There was a significant age dependent decrease in UPST time during both conditions. Inter-rater reliability for the best of 3 trials was determined to be excellent with an intra-class correlation coefficient of 0.994 (95% confidence interval 0.989-0.996) for eyes open and 0.998 (95% confidence interval 0.996-0.999) for eyes closed. This study adds to the understanding of typical performance on the UPST. Performance is age-specific and not related to gender. Clinicians now have more extensive normative values to which individuals can be compared.

  19. HDF-EOS Web Server

    Science.gov (United States)

    Ullman, Richard; Bane, Bob; Yang, Jingli

    2008-01-01

    A shell script has been written as a means of automatically making HDF-EOS-formatted data sets available via the World Wide Web. ("HDF-EOS" and variants thereof are defined in the first of the two immediately preceding articles.) The shell script chains together some software tools developed by the Data Usability Group at Goddard Space Flight Center to perform the following actions: Extract metadata in Object Definition Language (ODL) from an HDF-EOS file, Convert the metadata from ODL to Extensible Markup Language (XML), Reformat the XML metadata into human-readable Hypertext Markup Language (HTML), Publish the HTML metadata and the original HDF-EOS file to a Web server and an Open-source Project for a Network Data Access Protocol (OPeN-DAP) server computer, and Reformat the XML metadata and submit the resulting file to the EOS Clearinghouse, which is a Web-based metadata clearinghouse that facilitates searching for, and exchange of, Earth-Science data.

  20. Research on the Features of Chlorophyll-a Derived from RapidEye and EOS/MODIS Data in Chaohu Lake

    International Nuclear Information System (INIS)

    Wen, X; Chen, B; Li, Z; Zhou, Z; Tang, X

    2014-01-01

    Chaohu Lake is one of the largest freshwater lakes in China, however, with the rapid expansion of Hefei, the water environment of Chaohu Lake shows significantly deterioration. In this paper, RapidEye and MODIS imagery were used to monitor the chlorophyll alpha (Chla) distribution in Chaohu Lake. After analyzing the correlation between in-situ measured Chla concentrations and each channel of RapidEye and MODIS imagery, the optimal band combination for the establishment of Chla concentration was determined. For RapidEye imagery, the red edge channel and near infrared channel are relatively more sensitive than other channels. The inversion model using the feature of (B5+B4)/(B2+B1) worked the best with the square value of correlation coefficient reaching up to 0.745. A similar procedure was applied to MODIS imagery. The experiments show that RapidEye with its red edge channel is an effective data source for water environment monitoring, it could provide high spatial resolution of Chla distribution thematic map, MODIS with its higher temporal resolution is also an effective data source in dynamically monitoring water environment. The Chla concentration in the western half of Chao Lake is higher than that in the eastern half

  1. Clinical Assessment of Lamina Cribrosa Curvature in Eyes with Primary Open-Angle Glaucoma.

    Directory of Open Access Journals (Sweden)

    Yong Woo Kim

    Full Text Available Quantitative evaluation of lamina cribrosa (LC posterior bowing in primary open-angle glaucoma (POAG eyes using swept-source optical coherence tomography.Patients with POAG (n = 123 eyes and healthy individuals of a similar age (n = 92 eyes were prospectively recruited. Anterior laminar insertion depth (ALID was defined as the vertical distance between the anterior laminar insertion and a reference plane connecting the Bruch's membrane openings (BMO. The mean LC depth (mLCD was approximated by dividing the area enclosed by the anterior LC, the BMO reference plane, and the two vertical lines for ALID measurement by the length between those two vertical lines. The LC curvature index was defined as the difference between the mLCD and the ALID. The factors influencing the LC curvature index were evaluated.The ALID and mLCD were significantly larger in POAG eyes than in healthy controls (P -6 dB and moderate-to-advanced glaucoma (MD < -6 dB, P = 0.95.LC posterior bowing was increased in POAG eyes, and was significantly associated with structural optic nerve head (ONH changes but not with functional glaucoma severity. Quantitative evaluation of LC curvature can facilitate assessment of glaucomatous ONH change.

  2. Personality traits neuroticism and openness as well as early abnormal eye conditions as predictors of the occurrence of eye problems in adulthood

    Directory of Open Access Journals (Sweden)

    Helen Cheng

    2017-06-01

    Full Text Available This study set out to examine the associations between psychological, biomedical and socio-demographic factors in childhood and adulthood associated with the occurrence of self-reported eye conditions in adulthood. In total, 5706 participants with complete data on parental social class at birth, cognitive ability accessed at age 11 years, abnormal eye conditions by the age of 16 years diagnosed by medical professionals, educational qualifications obtained at age 33 years, the Big Five Factor personality traits measured at age 50 years, current occupational levels and self-reported eye conditions at age 54 years were included in the study. Logistic regression analysis showed that among all the factors examined early abnormal eye conditions, traits neuroticism and openness as well as sex were the significant predictors of self-reported eye conditions in adulthood.

  3. Predictive value of ocular trauma score in open globe combat eye injuries

    International Nuclear Information System (INIS)

    Islam, Q.

    2016-01-01

    Prediction of final visual outcome in ocular injuries is of paramount importance and various prognostic models have been proposed to predict final visual outcome. The objective of this study was to validate the predictive value of ocular trauma score (OTS) in patients with combat related open globe injuries and to evaluate the factors affecting the final visual outcome. Methods: Data of 93 patients admitted in AFIO Rawalpindi between Jan 2010 to June 2014 with combat related open globe ocular injuries was analysed. Initial and final best corrected visual acuity (BCVA) was categorized as No Light Perception (NLP), Light Perception (LP) to Hand Movement (HM), 1/200-19/200, 20/200-20/50, and =20/40. OTS was calculated for each eye by assigning numerical raw points to six variables and then scores were stratified into five OTS categories. Results: Mean age of study population was 28.77 ± 8.37 years. Presenting visual acuity was <20/200 (6/60) in 103 (96.23%) eyes. However, final BCVA of =20/40 (6/12) was achieved in 18 (16.82%) eyes, while 72 (67.28%) eyes had final BCVA of <20/200 (6/60). Final visual outcome in our study were similar to those in OTS study, except for NLP in category 1 (81% vs. 74%) and =20/40 in category 3 (30% vs. 41%). The OTS model predicted visual survival (LP or better) with a sensitivity of 94.80% and predicted no vision (NLP) with a specificity of 100%. Conclusion: OTS is a reliable tool for assessment of ocular injuries and predicting final visual outcome at the outset. (author)

  4. An EEG-Based Person Authentication System with Open-Set Capability Combining Eye Blinking Signals.

    Science.gov (United States)

    Wu, Qunjian; Zeng, Ying; Zhang, Chi; Tong, Li; Yan, Bin

    2018-01-24

    The electroencephalogram (EEG) signal represents a subject's specific brain activity patterns and is considered as an ideal biometric given its superior forgery prevention. However, the accuracy and stability of the current EEG-based person authentication systems are still unsatisfactory in practical application. In this paper, a multi-task EEG-based person authentication system combining eye blinking is proposed, which can achieve high precision and robustness. Firstly, we design a novel EEG-based biometric evoked paradigm using self- or non-self-face rapid serial visual presentation (RSVP). The designed paradigm could obtain a distinct and stable biometric trait from EEG with a lower time cost. Secondly, the event-related potential (ERP) features and morphological features are extracted from EEG signals and eye blinking signals, respectively. Thirdly, convolutional neural network and back propagation neural network are severally designed to gain the score estimation of EEG features and eye blinking features. Finally, a score fusion technology based on least square method is proposed to get the final estimation score. The performance of multi-task authentication system is improved significantly compared to the system using EEG only, with an increasing average accuracy from 92.4% to 97.6%. Moreover, open-set authentication tests for additional imposters and permanence tests for users are conducted to simulate the practical scenarios, which have never been employed in previous EEG-based person authentication systems. A mean false accepted rate (FAR) of 3.90% and a mean false rejected rate (FRR) of 3.87% are accomplished in open-set authentication tests and permanence tests, respectively, which illustrate the open-set authentication and permanence capability of our systems.

  5. Feasibility of eyes open alpha power training for mental enhancement in elite gymnasts.

    Science.gov (United States)

    Dekker, Marian K J; van den Berg, Berber R; Denissen, Ad J M; Sitskoorn, Margriet M; van Boxtel, Geert J M

    2014-01-01

    This study focuses on a novel, easy to use and instruction-less method for mental training in athletes. Previous findings suggest that particular mental capacities are needed for achieving peak performance; including attentional control, focus, relaxation and positive affect. Electroencephalography (EEG) alpha brain activity has been associated with neural inhibition during processes of selective attention, for improving efficiency in information processing. Here we hypothesised that eyes open alpha power training by music teaches athletes to (1) learn to self-regulate their brain activity, and (2) learn to increase their baseline alpha power, herewith improving mental capacities such as focusing the allocation of attention. The study was double-blind and placebo-controlled. Twelve elite gymnasts were either given eyes open alpha power training or random beta power training (controls). Results indicate small improvements in sleep quality, mental and physical shape. In our first attempt at getting a grip on mental capacities in athletes, we think this novel training method can be promising. Because gymnastics is one of the most mentally demanding sports, we value even small benefits for the athlete and consider them indicative for future research.

  6. A Study of Deep CNN-Based Classification of Open and Closed Eyes Using a Visible Light Camera Sensor

    Directory of Open Access Journals (Sweden)

    Ki Wan Kim

    2017-06-01

    Full Text Available The necessity for the classification of open and closed eyes is increasing in various fields, including analysis of eye fatigue in 3D TVs, analysis of the psychological states of test subjects, and eye status tracking-based driver drowsiness detection. Previous studies have used various methods to distinguish between open and closed eyes, such as classifiers based on the features obtained from image binarization, edge operators, or texture analysis. However, when it comes to eye images with different lighting conditions and resolutions, it can be difficult to find an optimal threshold for image binarization or optimal filters for edge and texture extraction. In order to address this issue, we propose a method to classify open and closed eye images with different conditions, acquired by a visible light camera, using a deep residual convolutional neural network. After conducting performance analysis on both self-collected and open databases, we have determined that the classification accuracy of the proposed method is superior to that of existing methods.

  7. It Security and EO Systems

    Science.gov (United States)

    Burnett, M.

    2010-12-01

    One topic that is beginning to influence the systems that support these goals is that of Information Technology (IT) Security. Unsecure systems are vulnerable to increasing attacks and other negative consequences; sponsoring agencies are correspondingly responding with more refined policies and more stringent security requirements. These affect how EO systems can meet the goals of data and service interoperability and harmonization through open access, transformation and visualization services. Contemporary systems, including the vision of a system-of-systems (such as GEOSS, the Global Earth Observation System of Systems), utilize technologies that support a distributed, global, net-centric environment. These types of systems have a high reliance on the open systems, web services, shared infrastructure and data standards. The broader IT industry has developed and used these technologies in their business and mission critical systems for many years. Unfortunately, the IT industry, and their customers have learned the importance of protecting their assets and resources (computing and information) as they have been forced to respond to an ever increasing number and more complex illegitimate “attackers”. This presentation will offer an overview of work done by the CEOS WGISS organization in summarizing security threats, the challenges to responding to them and capturing the current state of the practice within the EO community.

  8. Theorising ageing and the question of a long life: eye openings

    Directory of Open Access Journals (Sweden)

    Simon Biggs

    2015-11-01

    Full Text Available A life course perspective, drawing on historical and personal experiences, is used to identify eye-opening concepts that can be used to make sense of the world in terms of personal and social ageing, in the context of intergenerational relationships. Two issues have been identified that characterise a challenge to cultural adaptation: that of generations increasingly becoming approximately the same size as they move from demographic triangles to columns, and that of finding an age-specific purpose for a long life. An analysis of contemporary problems facing gerontology and social policy is given, drawing on the need for complementary life priorities and enhanced generational intelligence. Implications for work, generational rivalry and precarity are examined along with some conclusions on the role of eyeopening conceptual development.

  9. PVT modeling of reservoir fluids using PC-SAFT EoS and Soave-BWR EoS

    DEFF Research Database (Denmark)

    Yan, Wei; Varzandeh, Farhad; Stenby, Erling Halfdan

    2015-01-01

    non-cubic EoS models, such as the Perturbed Chain Statistical Associating Fluid Theory (PC-SAFT) EoS and the Soave modified Benedict-Webb-Rubin (Soave-BWR) EoS, may partly replace the roles of these classical cubic models in the upstream oil industry. Here, we attempt to make a comparative study...... for the four models. For PVT prediction, the non-cubic models show advantages in some high pressure high temperature (HPHT) fluids but no clear advantages in general, indicating the necessity for further improvement of the characterization procedure....

  10. EOS Inoovation Photo's

    International Nuclear Information System (INIS)

    2011-01-01

    What did four years of energy innovation bring the Netherlands? Which are the main lessons learned and what are the best opportunities for the market? The Energy Research Strategy programme (EOS) gave the answers to these questions for various topics in the form of images by means of so-called I nnovation Photos' on Biomass, Built Environment, Industrial Energy Efficiency, Smart Grids, Heat, Offshore Wind, and Solar PV. [nl

  11. Scaling the EOS namespace

    CERN Document Server

    Peters, Andreas J; Bitzes, Georgios

    2017-01-01

    EOS is the distributed storage system being developed at CERN with the aim of fulfilling a wide range of data storage needs, ranging from physics data to user home directories. Being in production since 2011, EOS currently manages around 224 petabytes of disk space and 1.4 billion files across several instances. Even though individual EOS instances routinely manage hundreds of disk servers, users access the contents through a single, unified namespace which is exposed by the head node (MGM), and contains the metadata of all files stored on that instance. The legacy implementation keeps the entire namespace in-memory. Modifications are appended to a persistent, on-disk changelog; this way, the in-memory contents can be reconstructed after every reboot by replaying the changelog. While this solution has proven reliable and effective, we are quickly approaching the limits of its scalability. In this paper, we present our new implementation which is currently in testing. We have designed and implemented QuarkD...

  12. Anterior segment parameters as predictors of intraocular pressure reduction after phacoemulsification in eyes with open-angle glaucoma.

    Science.gov (United States)

    Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C

    2017-07-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2  = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2  = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2  = 0.52), and lens vault (β = -0.002, P = .009, R 2  = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Eos Chaos Rocks

    Science.gov (United States)

    2006-01-01

    11 January 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows light-toned, layered rock outcrops in Eos Chaos, located near the east end of the Valles Marineris trough system. The outcrops occur in the form of a distinct, circular butte (upper half of image) and a high slope (lower half of image). The rocks might be sedimentary rocks, similar to those found elsewhere exposed in the Valles Marineris system and the chaotic terrain to the east of the region. Location near: 12.9oS, 49.5oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Southern Summer

  14. Electrical overstress (EOS) devices, circuits and systems

    CERN Document Server

    Voldman, Steven H

    2013-01-01

    Electrical Overstress (EOS) continues to impact semiconductor manufacturing, semiconductor components and systems as technologies scale from micro- to nano-electronics.  This bookteaches the fundamentals of electrical overstress  and how to minimize and mitigate EOS failures. The text provides a clear picture of EOS phenomena, EOS origins, EOS sources, EOS physics, EOS failure mechanisms, and EOS on-chip and system design.  It provides an illuminating insight into the sources of EOS in manufacturing, integration of on-chip, and system level EOS protection networks, followed by examples in spe

  15. Evalutation of efficiency of dynamic laser magnetic stimulation of eye drainage system of patients with open angle glaucomatosis

    Directory of Open Access Journals (Sweden)

    Sidelnikova V.S.

    2014-06-01

    Full Text Available The purpose of the study is to develop a comprehensive treatment aimed at improving uveoscleral outflow in the application of dynamic laser magnetic stimulation of the drainage system of the eye and evaluation of its effectiveness in treating patients with primary open-angle glaucoma (POAG. Material. 106 patients diagnosed POAG I, II, III stages were examined. Group 1 consisted of 62 patients treated with medical therapy and dynamic laser magnetic stimulation of the drainage system of the eye using the "AMO-ATOS-ICL", produced by JSC "TRIMA", Saratov. Group 2 consisted of 64 patients who received only medical therapy. Comprehensive survey including standard eye examination, static perimetry, visual evoked potentials study, the study of intraocular blood flow was conducted to all patients. Analysis of the results of the complex therapeutic effects showed that as the result of treatment 73% of patients had a decrease of intraocular pressure and the ease factor outflow increase. 52% of patients had a decrease in the number and area of relative. 63% of patients had activation of intraocular blood flow. These indices remained stable for three months. Conclusion. The treatment with the technique of dynamic laser magnetic stimulation of the drainage system of the eye of patients with primary open-angle glaucoma leads to lower intraocular pressure, and to the improvement of dopple-rographic and perimetric indications.

  16. HDF-EOS Dump Tools

    Science.gov (United States)

    Prasad, U.; Rahabi, A.

    2001-05-01

    The following utilities developed for HDF-EOS format data dump are of special use for Earth science data for NASA's Earth Observation System (EOS). This poster demonstrates their use and application. The first four tools take HDF-EOS data files as input. HDF-EOS Metadata Dumper - metadmp Metadata dumper extracts metadata from EOS data granules. It operates by simply copying blocks of metadata from the file to the standard output. It does not process the metadata in any way. Since all metadata in EOS granules is encoded in the Object Description Language (ODL), the output of metadmp will be in the form of complete ODL statements. EOS data granules may contain up to three different sets of metadata (Core, Archive, and Structural Metadata). HDF-EOS Contents Dumper - heosls Heosls dumper displays the contents of HDF-EOS files. This utility provides detailed information on the POINT, SWATH, and GRID data sets. in the files. For example: it will list, the Geo-location fields, Data fields and objects. HDF-EOS ASCII Dumper - asciidmp The ASCII dump utility extracts fields from EOS data granules into plain ASCII text. The output from asciidmp should be easily human readable. With minor editing, asciidmp's output can be made ingestible by any application with ASCII import capabilities. HDF-EOS Binary Dumper - bindmp The binary dumper utility dumps HDF-EOS objects in binary format. This is useful for feeding the output of it into existing program, which does not understand HDF, for example: custom software and COTS products. HDF-EOS User Friendly Metadata - UFM The UFM utility tool is useful for viewing ECS metadata. UFM takes an EOSDIS ODL metadata file and produces an HTML report of the metadata for display using a web browser. HDF-EOS METCHECK - METCHECK METCHECK can be invoked from either Unix or Dos environment with a set of command line options that a user might use to direct the tool inputs and output . METCHECK validates the inventory metadata in (.met file) using The

  17. An Open Conversation on Using Eye-Gaze Methods in Studies of Neurodevelopmental Disorders

    Science.gov (United States)

    Venker, Courtney E.; Kover, Sara T.

    2015-01-01

    Purpose: Eye-gaze methods have the potential to advance the study of neurodevelopmental disorders. Despite their increasing use, challenges arise in using these methods with individuals with neurodevelopmental disorders and in reporting sufficient methodological detail such that the resulting research is replicable and interpretable. Method: This…

  18. EOS Terra Validation Program

    Science.gov (United States)

    Starr, David

    2000-01-01

    The EOS Terra mission will be launched in July 1999. This mission has great relevance to the atmospheric radiation community and global change issues. Terra instruments include Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), Clouds and Earth's Radiant Energy System (CERES), Multi-Angle Imaging Spectroradiometer (MISR), Moderate Resolution Imaging Spectroradiometer (MODIS) and Measurements of Pollution in the Troposphere (MOPITT). In addition to the fundamental radiance data sets, numerous global science data products will be generated, including various Earth radiation budget, cloud and aerosol parameters, as well as land surface, terrestrial ecology, ocean color, and atmospheric chemistry parameters. Significant investments have been made in on-board calibration to ensure the quality of the radiance observations. A key component of the Terra mission is the validation of the science data products. This is essential for a mission focused on global change issues and the underlying processes. The Terra algorithms have been subject to extensive pre-launch testing with field data whenever possible. Intensive efforts will be made to validate the Terra data products after launch. These include validation of instrument calibration (vicarious calibration) experiments, instrument and cross-platform comparisons, routine collection of high quality correlative data from ground-based networks, such as AERONET, and intensive sites, such as the SGP ARM site, as well as a variety field experiments, cruises, etc. Airborne simulator instruments have been developed for the field experiment and underflight activities including the MODIS Airborne Simulator (MAS) AirMISR, MASTER (MODIS-ASTER), and MOPITT-A. All are integrated on the NASA ER-2 though low altitude platforms are more typically used for MASTER. MATR is an additional sensor used for MOPITT algorithm development and validation. The intensive validation activities planned for the first year of the Terra

  19. Effect of laser UV radiation on the eye scleral tissue in patients with open-angle glaucoma

    Science.gov (United States)

    Razhev, A. M.; Iskakov, I. A.; Churkin, D. S.; Orishich, A. M.; Maslov, N. A.; Tsibul'skaya, E. O.; Lomzov, A. A.; Ermakova, O. V.; Trunov, A. N.; Chernykh, V. V.

    2018-05-01

    We report the results of an experimental study of the effect of short-pulse laser UV radiation on the eye scleral tissue. As samples, we used isolated flaps of the eye scleral tissue from the patients with open-angle glaucoma of the second and third stages. The impact was implemented using the radiation of an excimer XeCl laser with a wavelength of 308 nm and a laser with a wavelength tunable within from 210 to 355 nm. Depending on the problem to be solved, the energy density on the surface of the irradiated tissue varied from a fraction of mJ cm-2 to 15 J cm-2. For the first time we studied the optical properties of the intraocular fluid in the UV and blue spectral range. The study of the ablation process under the action of radiation with a wavelength of 308 nm showed that the rate of material evaporation can vary within 24%–30% at an energy density above 7 J cm-2, depending on the glaucoma stage and the individual features of a patient. The excitation–emission matrices of laser-induced fluorescence (LIF) of the eye scleral tissue were studied experimentally using a laser with a wavelength tuned in the range 210–355 nm. We found the differences in the LIF spectra caused by the excitation wavelength and the openangle glaucoma stage.

  20. Bridging EO Research, Operations and Collaborative Learning

    Science.gov (United States)

    Scarth, Peter

    2016-04-01

    Building flexible and responsive processing and delivery systems is key to getting EO information used by researchers, policy agents and the public. There are typically three distinct processes we tackle to get product uptake: undertake research, operationalise the validated research, and deliver information and garner feedback in an appropriate way. In many cases however, the gaps between these process elements are large and lead to poor outcomes. Good research may be "lost" and not adopted, there may be resistance to uptake by government or NGOs of significantly better operational products based on EO data, and lack of accessibility means that there is no use of interactive science outputs to improve cross disciplinary science or to start a dialog with citizens. So one of the the most important tasks, if we wish to have broad uptake of EO information and accelerate further research, is to link these processes together in a formal but flexible way. One of the ways to operationalize research output is by building a platform that can take research code and scale it across much larger areas. In remote sensing, this is typically a system that has access to current and historical corrected imagery with a processing pipeline built over the top. To reduce the demand on high level scientific programmers and allowing cross disciplinary researchers to hack and play and refine, this pipeline needs to be easy to use, collaborative and link to existing tools to encourage code experimentation and reuse. It is also critical to have efficient, tight integration with information delivery and extension components so that the science relevant to your user is available quickly and efficiently. The rapid expansion of open data licensing has helped this process, but building top-down web portals and tools without flexibility and regard for end user needs has limited the use of EO information in many areas. This research reports on the operalization of a scale independent time series

  1. PREDICTING PROGNOSTIC VALUE OF OCULAR TRAUMA SCORE (OTS IN AN OPEN GLOBE INJURY IN TERTIARY EYE CARE HOSPITAL

    Directory of Open Access Journals (Sweden)

    Rahul

    2015-10-01

    Full Text Available AIM : To evaluate the prognostic value of OTS in open globe injuries. MATERIAL METHOD : Retrospective analysis of 77 eyes with open globe injuries was done from 01/07/2013 to 31/12/2014. Patients were assigned raw score sum based on initial V/A, and ocular findings then classified into 5 categories for predicting final visual outcome based on ocular Trauma score (OTS. RESULT : We estimated final V/A in 77 cases of open globe injuries (64.93% had raw sc ore between 65.91 (category 3, 4 Six months after the injury, 42.85% patients of categories 1 (raw score 0 - 44 achieved V/A of PL/HM as compared to 17% in OTS study. 16 patients with raw compared to OTS study. We reported comparable visual outcome with OT S study except in category 1 & 2. CONCLUSION: OTS score is valuable in triage, patient counseling and decision making for the management of ocular trauma. We recommend that OTS should be used routinely for open globe injuries as it is a simple guide

  2. EyeDroid: An Open Source Mobile Gaze Tracker on Android for Eyewear Computers

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbeigi, Diako; Sintos, Ioannis

    2015-01-01

    In this paper we report on development and evaluation of a video-based mobile gaze tracker for eyewear computers. Unlike most of the previous work, our system performs all its processing workload on an Android device and sends the coordinates of the gaze point to an eyewear device through wireless...... connection. We propose a lightweight software architecture for Android to increase the efficiency of image processing needed for eye tracking. The evaluation of the system indicated an accuracy of 1:06 and a battery lifetime of approximate 4.5 hours....

  3. A watershed model to integrate EO data

    Science.gov (United States)

    Jauch, Eduardo; Chambel-Leitao, Pedro; Carina, Almeida; Brito, David; Cherif, Ines; Alexandridis, Thomas; Neves, Ramiro

    2013-04-01

    MOHID LAND is a open source watershed model developed by MARETEC and is part of the MOHID Framework. It integrates four mediums (or compartments): porous media, surface, rivers and atmosphere. The movement of water between these mediums are based on mass and momentum balance equations. The atmosphere medium is not explicity simulated. Instead, it's used as boundary condition to the model through meteorological properties: precipitation, solar radiation, wind speed/direction, relative humidity and air temperature. The surface medium includes the overland runoff and vegetation growth processes and is simulated using a 2D grid. The porous media includes both the unsaturated (soil) and saturated zones (aquifer) and is simulated using a 3D grid. The river flow is simulated through a 1D drainage network. All these mediums are linked through evapotranspiration and flow exchanges (infiltration, river-soil growndwater flow, surface-river overland flow). Besides the water movement, it is also possible to simulate water quality processes and solute/sediment transport. Model setup include the definition of the geometry and the properties of each one of its compartments. After the setup of the model, the only continuous input data that MOHID LAND requires are the atmosphere properties (boundary conditions) that can be provided as timeseries or spacial data. MOHID LAND has been adapted the last 4 years under FP7 and ESA projects to integrate Earth Observation (EO) data, both variable in time and in space. EO data can be used to calibrate/validate or as input/assimilation data to the model. The currently EO data used include LULC (Land Use Land Cover) maps, LAI (Leaf Area Index) maps, EVTP (Evapotranspiration) maps and SWC (Soil Water Content) maps. Model results are improved by the EO data, but the advantage of this integration is that the model can still run without the EO data. This means that model do not stop due to unavailability of EO data and can run on a forecast mode

  4. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.

    Science.gov (United States)

    Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka

    2018-03-01

    To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.

  5. Opacplot2: Enabling tabulated EoS and opacity compatibility for HEDLP simulations with the FLASH code

    Science.gov (United States)

    Laune, Jordan; Tzeferacos, Petros; Feister, Scott; Fatenejad, Milad; Yurchak, Roman; Flocke, Norbert; Weide, Klaus; Lamb, Donald

    2017-10-01

    Thermodynamic and opacity properties of materials are necessary to accurately simulate laser-driven laboratory experiments. Such data are compiled in tabular format since the thermodynamic range that needs to be covered cannot be described with one single theoretical model. Moreover, tabulated data can be made available prior to runtime, reducing both compute cost and code complexity. This approach is employed by the FLASH code. Equation of state (EoS) and opacity data comes in various formats, matrix-layouts, and file-structures. We discuss recent developments on opacplot2, an open-source Python module that manipulates tabulated EoS and opacity data. We present software that builds upon opacplot2 and enables easy-to-use conversion of different table formats into the IONMIX format, the native tabular input used by FLASH. Our work enables FLASH users to take advantage of a wider range of accurate EoS and opacity tables in simulating HELP experiments at the National Laser User Facilities.

  6. On Application of Non-cubic EoS to Compositional Reservoir Simulation

    DEFF Research Database (Denmark)

    Yan, Wei; Michelsen, Michael Locht; Stenby, Erling Halfdan

    Compositional reservoir simulation uses almost exclusively cubic equations of state (EoS) such as the SRK EoS and the PR EoS. This is in contrast with process simulation in the downstream industry where more recent and advanced thermodynamic models are quickly adopted. Many of these models are non-cubic...... EoS, such as the PC-SAFT EoS. A major reason for the use of the conventional cubic EoS in reservoir simulation is the concern over computation time. Flash computation is the most time consuming part in compositional reservoir simulation, and the extra complexity of the non-cubic EoS may significantly...... increase the time consumption. In addition to this, the non-cubic EoS also needs a C7+ characterization. The main advantage of the non-cubic EoS is that it provides for a more accurate descrition of fluid properties, and it is therefore of interest to investigate the computational aspects of using...

  7. Global EOS: exploring the 300-ms-latency region

    Science.gov (United States)

    Mascetti, L.; Jericho, D.; Hsu, C.-Y.

    2017-10-01

    EOS, the CERN open-source distributed disk storage system, provides the highperformance storage solution for HEP analysis and the back-end for various work-flows. Recently EOS became the back-end of CERNBox, the cloud synchronisation service for CERN users. EOS can be used to take advantage of wide-area distributed installations: for the last few years CERN EOS uses a common deployment across two computer centres (Geneva-Meyrin and Budapest-Wigner) about 1,000 km apart (∼20-ms latency) with about 200 PB of disk (JBOD). In late 2015, the CERN-IT Storage group and AARNET (Australia) set-up a challenging R&D project: a single EOS instance between CERN and AARNET with more than 300ms latency (16,500 km apart). This paper will report about the success in deploy and run a distributed storage system between Europe (Geneva, Budapest), Australia (Melbourne) and later in Asia (ASGC Taipei), allowing different type of data placement and data access across these four sites.

  8. Integrating new Storage Technologies into EOS

    Science.gov (United States)

    Peters, Andreas J.; van der Ster, Dan C.; Rocha, Joaquim; Lensing, Paul

    2015-12-01

    The EOS[1] storage software was designed to cover CERN disk-only storage use cases in the medium-term trading scalability against latency. To cover and prepare for long-term requirements the CERN IT data and storage services group (DSS) is actively conducting R&D and open source contributions to experiment with a next generation storage software based on CEPH[3] and ethernet enabled disk drives. CEPH provides a scale-out object storage system RADOS and additionally various optional high-level services like S3 gateway, RADOS block devices and a POSIX compliant file system CephFS. The acquisition of CEPH by Redhat underlines the promising role of CEPH as the open source storage platform of the future. CERN IT is running a CEPH service in the context of OpenStack on a moderate scale of 1 PB replicated storage. Building a 100+PB storage system based on CEPH will require software and hardware tuning. It is of capital importance to demonstrate the feasibility and possibly iron out bottlenecks and blocking issues beforehand. The main idea behind this R&D is to leverage and contribute to existing building blocks in the CEPH storage stack and implement a few CERN specific requirements in a thin, customisable storage layer. A second research topic is the integration of ethernet enabled disks. This paper introduces various ongoing open source developments, their status and applicability.

  9. Preservative-free versus preserved latanoprost eye drops in patients with open-angle glaucoma or ocular hypertension.

    Science.gov (United States)

    Aptel, Florent; Choudhry, Reena; Stalmans, Ingeborg

    2016-08-01

    This study compared the efficacy, safety, and pharmacokinetics of a preservative-free latanoprost formulation to an established, benzalkonium chloride (BAK) containing formulation for the treatment of open-angle glaucoma or ocular hypertension. This was a phase II, randomized, cross-over, investigator-masked, multi-center, pilot study (NCT01494753). A total of 30 untreated adult patients (aged ≥18 years) with primary open angle glaucoma, pseudo-exfoliative glaucoma, pigmentary glaucoma, or ocular hypertension received either preservative-free or preserved latanoprost once daily in both eyes for 6 weeks, before crossing over to receive the other treatment. Efficacy (intraocular pressure [IOP] at 8 am, midday, 4 pm and 8 pm, and global efficacy assessment by investigator), safety (adverse events, ocular symptoms and global tolerance, slit lamp examination, funduscopy, visual field examination, visual acuity, and heart rate), and pharmacokinetics were assessed at Days 0, 42, and 84. Both treatments resulted in a reduction in IOP that was similar for the preservative-free and the preserved formulation at all time points. Similarly, the overall diurnal reduction was similar in both groups (6.3 mmHg [27.9% reduction] and 6.4 mmHg [28.1% reduction] for preserved and preservative-free latanoprost, respectively). There were no differences in global efficacy assessment or in the safety and tolerance of each treatment. Systemic concentrations of latanoprost were very low; AUC0-30 and Cmax were lower and tmax was longer for preservative-free latanoprost. Preservative-free latanoprost showed similar efficacy at all time points compared to BAK preservative containing formulation, with no difference in tolerance, allowing progression to phase III clinical development.

  10. Experience-dependent plasticity from eye opening enables lasting, visual cortex-dependent enhancement of motion vision.

    Science.gov (United States)

    Prusky, Glen T; Silver, Byron D; Tschetter, Wayne W; Alam, Nazia M; Douglas, Robert M

    2008-09-24

    Developmentally regulated plasticity of vision has generally been associated with "sensitive" or "critical" periods in juvenile life, wherein visual deprivation leads to loss of visual function. Here we report an enabling form of visual plasticity that commences in infant rats from eye opening, in which daily threshold testing of optokinetic tracking, amid otherwise normal visual experience, stimulates enduring, visual cortex-dependent enhancement (>60%) of the spatial frequency threshold for tracking. The perceptual ability to use spatial frequency in discriminating between moving visual stimuli is also improved by the testing experience. The capacity for inducing enhancement is transitory and effectively limited to infancy; however, enhanced responses are not consolidated and maintained unless in-kind testing experience continues uninterrupted into juvenile life. The data show that selective visual experience from infancy can alone enable visual function. They also indicate that plasticity associated with visual deprivation may not be the only cause of developmental visual dysfunction, because we found that experientially inducing enhancement in late infancy, without subsequent reinforcement of the experience in early juvenile life, can lead to enduring loss of function.

  11. High-Fidelity Simulation of Pediatric Emergency Care: An Eye-Opening Experience for Baccalaureate Nursing Students.

    Science.gov (United States)

    Small, Sandra P; Colbourne, Peggy A; Murray, Cynthia L

    2018-01-01

    Background Little attention has been given to in-depth examination of what high-fidelity simulation is like for nursing students within the context of a pediatric emergency, such as a cardiopulmonary arrest. It is possible that such high-fidelity simulation could provoke in nursing students intense psychological reactions. Purpose The purpose of this study was to learn about baccalaureate nursing students' lived experience of high-fidelity simulation of pediatric cardiopulmonary arrest. Method Phenomenological methods were used. Twenty-four interviews were conducted with 12 students and were analyzed for themes. Results The essence of the experience is that it was eye-opening. The students found the simulation to be a surprisingly realistic nursing experience as reflected in their perceiving the manikin as a real patient, thinking that they were saving their patient's life, feeling like a real nurse, and feeling relief after mounting stress. It was a surprisingly valuable learning experience in that the students had an increased awareness of the art and science of nursing and increased understanding of the importance of teamwork and were feeling more prepared for clinical practice and wanting more simulation experiences. Conclusion Educators should capitalize on the benefits of high-fidelity simulation as a pedagogy, while endeavoring to provide psychologically safe learning.

  12. Integrating new Storage Technologies into EOS

    CERN Document Server

    Peters, Andreas J; Rocha, Joaquim; Lensing, Paul

    2015-01-01

    The EOS[1] storage software was designed to cover CERN disk-only storage use cases in the medium-term trading scalability against latency. To cover and prepare for long-term requirements the CERN IT data and storage services group (DSS) is actively conducting R&D; and open source contributions to experiment with a next generation storage software based on CEPH[3] and ethernet enabled disk drives. CEPH provides a scale-out object storage system RADOS and additionally various optional high-level services like S3 gateway, RADOS block devices and a POSIX compliant file system CephFS. The acquisition of CEPH by Redhat underlines the promising role of CEPH as the open source storage platform of the future. CERN IT is running a CEPH service in the context of OpenStack on a moderate scale of 1 PB replicated storage. Building a 100+PB storage system based on CEPH will require software and hardware tuning. It is of capital importance to demonstrate the feasibility and possibly iron out bottlenecks and blocking issu...

  13. Seeing the soil through the net: an eye-opener on the soil map of the Flemish region (Belgium)

    Science.gov (United States)

    Dondeyne, Stefaan; Vanierschot, Laura; Langohr, Roger; Van Ranst, Eric; Deckers, Jozef; Oorts, Katrien

    2017-04-01

    A systematic soil survey of Belgium was conducted from 1948 to 1991. Field surveys were done at the detailed scale of 1:5000 with the final maps published at a 1:20,000 scale. The legend of these detailed soil maps (scale 1:20,000) has been converted to the 3rd edition of the international soil classification system 'World Reference Base for Soil Resources' (WRB). Over the last years, the government of the Flemish region made great efforts to make these maps, along with other environmental data, available to the general audience through the internet. The soil maps are widely used and consulted by researchers, teachers, land-use planners, environmental consultancy agencies and archaeologists. The maps can be downloaded and consulted in the viewer 'Visual Soil Explorer' ('Bodemverkenner'). To increase the legibility of the maps, we assembled a collection of photographs from soil profiles representing 923 soil types and 413 photos of related landscape settings. By clicking on a specific location in the 'Visual Soil Explorer', pictures of the corresponding soil type and landscape appear in a pop-up window, with a brief explanation about the soil properties. The collection of photographs of soil profiles cover almost 80% of the total area of the Flemish region, and include the 100 most common soil types. Our own teaching experience shows that these information layers are particular valuable for teaching soil geography and earth sciences in general. Overall, such visual information layers should contribute to a better interpretation of the soil maps and legacy soil data by serving as an eye-opener on the soil map to the wider community.

  14. An Observation Capability Metadata Model for EO Sensor Discovery in Sensor Web Enablement Environments

    Directory of Open Access Journals (Sweden)

    Chuli Hu

    2014-10-01

    Full Text Available Accurate and fine-grained discovery by diverse Earth observation (EO sensors ensures a comprehensive response to collaborative observation-required emergency tasks. This discovery remains a challenge in an EO sensor web environment. In this study, we propose an EO sensor observation capability metadata model that reuses and extends the existing sensor observation-related metadata standards to enable the accurate and fine-grained discovery of EO sensors. The proposed model is composed of five sub-modules, namely, ObservationBreadth, ObservationDepth, ObservationFrequency, ObservationQuality and ObservationData. The model is applied to different types of EO sensors and is formalized by the Open Geospatial Consortium Sensor Model Language 1.0. The GeosensorQuery prototype retrieves the qualified EO sensors based on the provided geo-event. An actual application to flood emergency observation in the Yangtze River Basin in China is conducted, and the results indicate that sensor inquiry can accurately achieve fine-grained discovery of qualified EO sensors and obtain enriched observation capability information. In summary, the proposed model enables an efficient encoding system that ensures minimum unification to represent the observation capabilities of EO sensors. The model functions as a foundation for the efficient discovery of EO sensors. In addition, the definition and development of this proposed EO sensor observation capability metadata model is a helpful step in extending the Sensor Model Language (SensorML 2.0 Profile for the description of the observation capabilities of EO sensors.

  15. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI for Kids >> About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  16. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI for Kids » About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  17. Prognostic factors for open globe injuries and correlation of Ocular Trauma Score at a tertiary referral eye care centre in Singapore

    Directory of Open Access Journals (Sweden)

    Rupesh Agrawal

    2013-01-01

    Full Text Available Objective: To evaluate the factors influencing final vision outcome after surgical repair of open globe injuries and to correlate the Ocular trauma score. Materials and Methods: Retrospective case analysis of patients with open globe injuries at a tertiary referral eye care centre in Singapore was performed. Pre-operative factors affecting final vision outcome in patients with open globe injury and correlation of ocular trauma score in our study with international ocular trauma scoring system was performed. Results: Case records of 172 eyes with open globe injury were analyzed. Mean age was 36. 67 years. Mean follow up was 12.26 m. Males were pre-dominantly affected. Initial visual acuity was ≥20/40, 20/50 < 20/200, 20/200- CF, HM- PL and NLP in 24 (14%, 39 (22.7%, 16 (9.3%, 66 (38.4% and 27 (15.7% eyes respectively. Final visual acuity was ≤20/40, 20/50 < 20/200, 20/200- 1/200, HM- PL and NLP in 76 (44.2%, 28 (16.3%, 11 (6.4%, 30 (17.4% and 27 (15.7% eyes respectively. Ocular trauma score in our study correlates with international ocular trauma scoring system. Conclusion: The present study showed pre-operative variables such as mode of injury, pre-operative visual acuity, traumatic cataract, hyphaema, relative afferent papillary defect, vitreous lossand vitreous hemorrhage to be adversely affecting the final vision outcome. Our study showed a good synchrony with international ocular trauma score (OTS and based on this study we were able to validate application of OTS in Singapore population. Recognizing these factors can help the surgeon in evidence based counseling.

  18. Limited Range Sesame EOS for Ta

    Energy Technology Data Exchange (ETDEWEB)

    Greeff, Carl William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Crockett, Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rudin, Sven Peter [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Burakovsky, Leonid [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-30

    A new Sesame EOS table for Ta has been released for testing. It is a limited range table covering T ≤ 26, 000 K and ρ ≤ 37.53 g/cc. The EOS is based on earlier analysis using DFT phonon calculations to infer the cold pressure from the Hugoniot. The cold curve has been extended into compression using new DFT calculations. The present EOS covers expansion into the gas phase. It is a multi-phase EOS with distinct liquid and solid phases. A cold shear modulus table (431) is included. This is based on an analytic interpolation of DFT calculations.

  19. Earth Observing System (EOS) Advanced Microwave Sounding Unit-A2 (EOS/AMSU-A): EOS Software Test Report

    Science.gov (United States)

    1998-01-01

    This document describes the results of the formal qualification test (FQT)/ Demonstration conducted on September 10, and 14, 1998 for the EOS AMSU-A2 instrument. The purpose of the report is to relate the results of the functional performance and interface tests of the software. This is the final submittal of the EOS/AMSU-A Software Test report.

  20. Rigorous theoretical constraint on constant negative EoS parameter [Formula: see text] and its effect for the late Universe.

    Science.gov (United States)

    Burgazli, Alvina; Eingorn, Maxim; Zhuk, Alexander

    In this paper, we consider the Universe at the late stage of its evolution and deep inside the cell of uniformity. At these scales, the Universe is filled with inhomogeneously distributed discrete structures (galaxies, groups and clusters of galaxies). Supposing that the Universe contains also the cosmological constant and a perfect fluid with a negative constant equation of state (EoS) parameter [Formula: see text] (e.g., quintessence, phantom or frustrated network of topological defects), we investigate scalar perturbations of the Friedmann-Robertson-Walker metrics due to inhomogeneities. Our analysis shows that, to be compatible with the theory of scalar perturbations, this perfect fluid, first, should be clustered and, second, should have the EoS parameter [Formula: see text]. In particular, this value corresponds to the frustrated network of cosmic strings. Therefore, the frustrated network of domain walls with [Formula: see text] is ruled out. A perfect fluid with [Formula: see text] neither accelerates nor decelerates the Universe. We also obtain the equation for the nonrelativistic gravitational potential created by a system of inhomogeneities. Due to the perfect fluid with [Formula: see text], the physically reasonable solutions take place for flat, open and closed Universes. This perfect fluid is concentrated around the inhomogeneities and results in screening of the gravitational potential.

  1. Converting from XML to HDF-EOS

    Science.gov (United States)

    Ullman, Richard; Bane, Bob; Yang, Jingli

    2008-01-01

    A computer program recreates an HDF-EOS file from an Extensible Markup Language (XML) representation of the contents of that file. This program is one of two programs written to enable testing of the schemas described in the immediately preceding article to determine whether the schemas capture all details of HDF-EOS files.

  2. Psoriasis: an eye opener – a cross-sectional study in a Tertiary Care Hospital of South India

    Directory of Open Access Journals (Sweden)

    Hari Kishan Kumar Yadalla

    2015-01-01

    Full Text Available Introduction: Psoriasis is a multi-system chronic inflammatory skin disease targeting 2% to 3% of the general population. It is a prototype of immune dysregulation mediated by TH1 proinflammatory cytokines such as TNF-α, IFN-gamma, IL-6, and IL-12 with far reaching systemic effects. There is growing and emerging evidence that psoriasis patients have a higher prevalence of associated comorbid diseases, with severe skin disease portends a serious risk for development of these comorbidities and are found to have a higher association of extracutaneous disease manifestations. Aim: To look for eye involvement in psoriasis patients and to evaluate the risk and prognostic factors of disease association. Material and Methods: 200 Patients with psoriasis were screened for any eye involvement after few unusual case presentations with eye complications during the period from September 2013 - August 2014. Results: First case was a post cataract sudden loss of vision secondary to development of uveitis in a female patient aged 52 years, with past history of psoriasis with minimal skin lesions and no arthritis. Another 5 cases of psoriasis with eye involvement were detected during the screening employed in a series of 200 psoriasis cases. Conclusion: The present report highlights the importance of psoriasis and eye involvement, need for collaboration between dermatologists and ophthalmologists for thorough examination and evaluation prior to any surgical intervention and also further long term follow-up studies are warranted for confirmation of this causal relationship.

  3. Adjuvant effect of Chakshushya Rasayana with beta-blocker eye drops in the management of progressive glaucomatous optic neuropathy: An open-label randomized controlled trial.

    Science.gov (United States)

    Dhiman, K S; Adhoor, Veeranagouda S; Agarwal, Riju; Mehta, Amit J

    2016-01-01

    Primary open angle glaucoma is an insidious and chronic vision-threatening eye ailment due to neuro-retino-optic nerve degeneration, which may be due to the raised intraocular pressure (IOP) or due to independent factors. Management of glaucoma is mainly concentrated on lowering IOP that requires lifetime topical medication, different ocular medicaments for lowering of IOP, and surgical interventions, but it has its own limitations to control the progression of glaucomatous optic neuropathy (GON), and this is the reason behind the use of alternative neuroprotective adjuvants. To evaluate the neuroprotective effect of Ayurvedic line of management of progressive GON. Ingredients of trial drug Vara Fort powder ( Chakshushya Rasayana ) were procured from the Institute Pharmacy, except Swarnamakshika Bhasma , which was purchased from Dhootapapeshwar Pharmaceuticals. The patients fulfilling inclusion criteria, attending outpatient and inpatient departments, irrespective of their sex, race, religion, occupation, etc., were selected and divided into two groups with open-labeled randomization. In Group A, in addition to betaxolol (0.1%) or timolol (0.5%) (non-iobrim), Chakshushya Rasayana 6 g/day orally with Triphala Ghrita and honey along with Koshtha-Shuddhi (body-microchannel clearing treatment) protocol was tried. Nasya (oleation through nasal route) with Jeevantyadi Taila and Tarpana (eye satiation) with Go-Ghrita were also performed. In Group B (control), brimonidine (iobrim) 0.2% eye drop was used for 3 months. Significant improvement was observed in subjective parameters in Group A such as blurred vision, frequent change of presbyopic glasses, and delayed dark adaptation. Chakshushya Rasayana , if administered in a systematic approach along with a modern topical betaxolol or timolol eye drops, has a definite role in improving the lost retinal sensitivity as much as up to 12 dB in 3 months duration.

  4. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  5. EO2HEAVEN: mitigating environmental health risks

    CSIR Research Space (South Africa)

    Le Rouw, Wouter J

    2013-01-01

    Full Text Available EO2HEAVEN has the primary objective to contribute to a better understanding of the complex relationships between environmental changes and their impact on human health. To achieve this, the project followed a multidisciplinary and user...

  6. The experimental investigation of explosive opening switch

    International Nuclear Information System (INIS)

    Zhang Jiande; Zhong Huihuang; Li Chuanlu; Liu Yonggui; Cheng Dongqun; Peng Xianyang

    1996-01-01

    The explosive opening switch (EOS) used in explosive-driven magnetic-flux compression generator (EMCG) circuits was investigated. It is shown that (1) under certain conditions, the EOS voltage is hardly dependent on the size of the explosive and aluminium foil used in EOS; (2) with the explosive coated by an insulator pipe, the opening effect of EOS is better; (3) by use of EOS, a pulse with 5 kA current, 100 kV voltage and 250 ns risetime has been transferred into a resistance load. (author). 12 figs., 5 refs

  7. The experimental investigation of explosive opening switch

    Energy Technology Data Exchange (ETDEWEB)

    Jiande, Zhang; Huihuang, Zhong; Chuanlu, Li; Yonggui, Liu; Dongqun, Cheng; Xianyang, Peng [National Univ. of Defense Technology, Changsha (China). Dept. of Applied Physics

    1997-12-31

    The explosive opening switch (EOS) used in explosive-driven magnetic-flux compression generator (EMCG) circuits was investigated. It is shown that (1) under certain conditions, the EOS voltage is hardly dependent on the size of the explosive and aluminium foil used in EOS; (2) with the explosive coated by an insulator pipe, the opening effect of EOS is better; (3) by use of EOS, a pulse with 5 kA current, 100 kV voltage and 250 ns risetime has been transferred into a resistance load. (author). 12 figs., 5 refs.

  8. Building EOS capability for Malaysia - the options

    Science.gov (United States)

    Subari, M. D.; Hassan, A.

    2014-06-01

    Earth observation satellite (EOS) is currently a major tool to monitor earth dynamics and increase human understanding of earth surface process. Since the early 80s, Malaysia has been using EOS images for various applications, such as weather forecasting, land use mapping, agriculture, environment monitoring and others. Until now, all EOS images were obtained from foreign satellite systems. Realising on the strategic need of having its own capability, Malaysia embarked into EOS development programs in the early 90s. Starting with TiungSAT-1, a micro-satellite carrying small camera, then followed by RazakSAT, a small satellite carrying 2.5 m panchromatic (PAN) medium-aperture-camera, the current satellite program development, the RazakSAT-2, designed to carry a 1.0 m high resolution PAN and 4.0m multi-spectral camera, would become a strategic initiative of the government in developing and accelerating the nation's capability in the area of satellite technology and its application. Would this effort continue until all needs of the remote sensing community being fulfilled by its own EOS? This paper will analyze the intention of the Malaysian government through its National Space Policy and other related policy documents, and proposes some policy options on this. Key factors to be considered are specific data need of the EOS community, data availability and the more subjective political motivations such as national pride.

  9. The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects.

    Science.gov (United States)

    Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen

    2016-06-01

    To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.

  10. Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Lin, Shan C; Masis, Marisse; Porco, Travis C; Pasquale, Louis R

    2017-08-01

    To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P <.001) reduction vs 2.5±3 mm Hg (16%, P <.001) in the wide-angle group ( P =.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year ( P <.05 for all). In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option.

  11. Starck Ta PTW strength model recommendation for use with SESAME 93524 EoS

    Energy Technology Data Exchange (ETDEWEB)

    Sjue, Sky K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Prime, Michael Bruce [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-27

    The purpose of this document is to provide a calibration of the Preston-Tonks- Wallace (PTW) strength model for use with the new SESAME equation of state (EoS) 93524. The calibration data included in this t spans temperatures from 198 K to 673 K and strain rates from 0.001/s to 3200/s.

  12. ASY-EOS experiment at GSI

    Directory of Open Access Journals (Sweden)

    Kezzar K.

    2012-07-01

    Full Text Available The elliptic-flow ratio of neutrons with respect to protons in reactions of neutron rich Heavy-Ion at intermediate energies has been recently proposed as an observable sensitive to the strength of the symmetry term in the nuclear equation of state (EOS at supra-saturation densities. The recent results obtained from the existing FOPI/LAND data for 197Au+197Au collisions at 400 MeV/nucleon in comparison with the UrQMD model allowed a first estimate of the symmetry term of the EOS but suffer from a considerable statistical uncertainty. In order to obtain an improved data set for Au+Au collisions and to extend the study to other systems, a new experiment was carried out at the GSI laboratory by the ASY-EOS collaboration in May 2011.

  13. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  14. Canadian Vehicle Protection Program (EO considerations)

    Science.gov (United States)

    2012-10-09

    Leopard 2 • Protection of the vehicle and their occupants was always considered on top of the priority list. • Currently, industry can provide...arge s 19 High Power Laser Characterization Laboratory 20 Conclusion • EO technologies are evolving extremely fast and cost/size/ weight is going down

  15. Complementarity of EO and radar systems

    NARCIS (Netherlands)

    Schwering, P.B.W.

    2001-01-01

    Electro-optics (EO), including infrared, systems have matured in the last decades, allowing for a wider variation of applications. In particular, developments in detector capability and signal processing have resulted in autonomous detection systems as well as surveillance systems for situational

  16. Data links for the EOS TPC

    International Nuclear Information System (INIS)

    Bieser, F.; Jones, R.; McParland, C.

    1991-01-01

    This paper reports on the design and performance of high speed data links and slower configuration control links used between the EOS TPC detector and the data processing electronics. Data rates of 5 MBytes/link are maintained over 30m with optical isolation. Pedestal subtraction, hit detection, and data reordering are performed online

  17. Data links for the EOS TPC

    International Nuclear Information System (INIS)

    Bieser, F.; Jones, R.; McParland, C.

    1990-10-01

    We report on the design and performance of high speed data links and slower configuration control links used between the EOS TPC detector and the data processing electronics. Data rates of 5MBytes/s/link are maintained over 30m with optical isolation. Pedestal subtraction, hit detection, and data reordering are performed online. 3 refs., 1 fig

  18. [The 8-year follow-up study for clinical diagnostic potentials of frequency-doubling technology perimetry for perimetrically normal eyes of open-angle glaucoma patients with unilateral visual field loss].

    Science.gov (United States)

    Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F

    2018-03-11

    Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two

  19. Yesterday's Students in Today's World—Open and Guided Inquiry Through the Eyes of Graduated High School Biology Students

    Science.gov (United States)

    Dorfman, Bat-Shahar; Issachar, Hagit; Zion, Michal

    2017-12-01

    Educational policy bodies worldwide have argued that practicing inquiry as a part of the K-12 curriculum would help prepare students for their lives as adults in today's world. This study investigated adults who graduated high school 9 years earlier with a major in biology, to determine how they perceive the inquiry project they experienced and its contribution to their lives. We characterized dynamic inquiry performances and the retrospective perceptions of the inquiry project. Data was collected by interviews with 17 individuals—nine who engaged in open inquiry and eight who engaged in guided inquiry in high school. Both groups shared similar expressions of the affective point of view and procedural understanding criteria of dynamic inquiry, but the groups differed in the expression of the criteria changes occurring during inquiry and learning as a process. Participants from both groups described the contribution of the projects to their lives as adults, developing skills and positive attitudes towards science and remembering the content knowledge and activities in which they were involved. They also described the support they received from their teachers. Results of this study imply that inquiry, and particularly open inquiry, helps develop valuable skills and personal attributes, which may help the students in their lives as future adults. This retrospective point of view may contribute to a deeper understanding of the long-term influences of inquiry-based learning on students.

  20. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Peterson

    Full Text Available Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT.Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years. ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL, length of scleral spur landmark (SSL to pupillary margin (SSL-to-PM, iris contour ratio (ICR = AISL/SSL-to-PM, pupil radius, radius of iris centroid (RICe, and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter.Mean (±SD values were 2.24 mm (±0.46, 4.06 mm (±0.27, 3.65 mm (±0.48, 4.16 mm (±0.47, 1.14 (±0.04, 1.51 mm2 (±0.23, and 38.42 μL (±4.91 for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002 and RICe (P = 0.027 decreased with age, while SSL-to-PM (P = 0.002 and AISL increased with age (P = 0.001. ICR (P = 0.54 and iris volume (P = 0.49 were not affected by age.This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.

  1. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  2. Hot super-dense compact object with particular EoS

    Science.gov (United States)

    Tito, E. P.; Pavlov, V. I.

    2018-03-01

    We show the possibility of existence of a self-gravitating spherically-symmetric equilibrium configuration for a neutral matter with neutron-like density, small mass M ≪ M_{⊙}, and small radius R ≪ R_{⊙}. We incorporate the effects of both the special and general theories of relativity. Such object may be formed in a cosmic cataclysm, perhaps an exotic one. Since the base equations of hydrostatic equilibrium are completed by the equation of state (EoS) for the matter of the object, we offer a novel, interpolating experimental data from high-energy physics, EoS which permits the existence of such compact system of finite radius. This EoS model possesses a critical state characterized by density ρc and temperature Tc. For such an object, we derive a radial distribution for the super-dense matter in "liquid" phase using Tolman-Oppenheimer-Volkoff equations for hydrostatic equilibrium. We demonstrate that a stable configuration is indeed possible (only) for temperatures smaller than the critical one. We derive the mass-radius relation (adjusted for relativistic corrections) for such small (M ≪ M_{⊙}) super-dense compact objects. The results are within the constraints established by both heavy-ion collision experiments and theoretical studies of neutron-rich matter.

  3. MMA-EoS: A Computational Framework for Mineralogical Thermodynamics

    Science.gov (United States)

    Chust, T. C.; Steinle-Neumann, G.; Dolejš, D.; Schuberth, B. S. A.; Bunge, H.-P.

    2017-12-01

    We present a newly developed software framework, MMA-EoS, that evaluates phase equilibria and thermodynamic properties of multicomponent systems by Gibbs energy minimization, with application to mantle petrology. The code is versatile in terms of the equation-of-state and mixing properties and allows for the computation of properties of single phases, solution phases, and multiphase aggregates. Currently, the open program distribution contains equation-of-state formulations widely used, that is, Caloric-Murnaghan, Caloric-Modified-Tait, and Birch-Murnaghan-Mie-Grüneisen-Debye models, with published databases included. Through its modular design and easily scripted database, MMA-EoS can readily be extended with new formulations of equations-of-state and changes or extensions to thermodynamic data sets. We demonstrate the application of the program by reproducing and comparing physical properties of mantle phases and assemblages with previously published work and experimental data, successively increasing complexity, up to computing phase equilibria of six-component compositions. Chemically complex systems allow us to trace the budget of minor chemical components in order to explore whether they lead to the formation of new phases or extend stability fields of existing ones. Self-consistently computed thermophysical properties for a homogeneous mantle and a mechanical mixture of slab lithologies show no discernible differences that require a heterogeneous mantle structure as has been suggested previously. Such examples illustrate how thermodynamics of mantle mineralogy can advance the study of Earth's interior.

  4. Eye Injuries at Home

    Science.gov (United States)

    ... by the Numbers — Infographic Five Steps to Safer Champagne Celebrations Eye Injuries at Home Leer en Español: ... that can splatter hot grease or oil. Opening champagne bottles during a celebration. Drilling or hammering screws ...

  5. Comparison of the diagnostic ability of Moorfield’s regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma

    Science.gov (United States)

    Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita

    2010-01-01

    Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832

  6. Comparison of the diagnostic ability of Moorfield′s regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Jindal Shveta

    2010-01-01

    Full Text Available Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT glaucoma probability score (GPS with that of Moorfield′s regression analysis (MRA. Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 - 0.315. The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives and least specific criteria (borderline results included as test positives. The MRA sensitivity and specificity were 30.61 and 98% (most specific and 57.14 and 98% (least specific. The GPS sensitivity and specificity were 81.63 and 73.47% (most specific and 95.92 and 34.69% (least specific. The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08 and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44.The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs.

  7. A nonrandomized, open-label study to evaluate the effect of nasal stimulation on tear production in subjects with dry eye disease.

    Science.gov (United States)

    Friedman, Neil J; Butron, Karla; Robledo, Nora; Loudin, James; Baba, Stephanie N; Chayet, Arturo

    2016-01-01

    Dry eye disease (DED), a chronic disorder affecting the tear film and lacrimal functional unit, is a widely prevalent condition associated with significant burden and unmet treatment needs. Since specific neural circuits play an important role in maintaining ocular surface health, microelectrical stimulation of these pathways could present a promising new approach to treating DED. This study evaluated the efficacy and safety of nasal electrical stimulation in patients with DED. This prospective, open-label, single-arm, nonrandomized pilot study included 40 patients with mild to severe DED. After undergoing two screening visits, enrolled subjects were provided with a nasal stimulation device and instructed to use it at home four times daily (or more often as needed). Follow-up assessments were conducted up to day 180. The primary efficacy endpoint was the difference between unstimulated and stimulated tear production quantified by Schirmer scores. Additional efficacy endpoints included change from baseline in corneal and conjunctival staining, symptoms evaluated on a Visual Analog Scale, and Ocular Surface Disease Index scores. Safety parameters included adverse event (AE) rates, visual acuity, intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, and endoscopic nasal examinations. Mean stimulated Schirmer scores were significantly higher than the unstimulated scores at all visits, and corneal and conjunctival staining and symptom scores from baseline to day 180 were significantly reduced. No serious device-related AEs and nine nonserious AEs (three device-related) were reported. Intraocular pressure remained stable and most subjects showed little or no change in visual acuity at days 30 and 180. No significant findings from other clinical examinations were noted. Neurostimulation of the nasolacrimal pathway is a safe and effective means of increasing tear production and reducing symptoms of dry eye in patients with DED.

  8. Applications of SSAFT EOS for determination of the solubilities of ...

    African Journals Online (AJOL)

    Applications of SSAFT EOS for determination of the solubilities of solid compounds in supercritical CO 2 . ... Using statistical thermodynamics such as Simplified SAFT equation of state (SSAFTEoS) for estimating phase equilibrium and fluid properties of different materials have been used widely. SSAFT EoS has been ...

  9. Strange particle measurements from the EOS TPC

    International Nuclear Information System (INIS)

    Justice, M.

    1995-02-01

    A high statistics sample of Λ's produced in 2 GeV/nucleon 5 8Ni + nat Cu collisions has been obtained with the EOS Time Projection Chamber at the Bevalac. The coverage of the EOS TPC is essentially 100% for y > y cm and extends down to P T = 0 where interesting effects such as collective radial expansion may be important. In addition, the detection of a majority of the charged particles in the TPC, along with the presence of directed flow for protons and heavier fragments at this beam energy, allows for the correlation of A production with respect to the event reaction plane. Our preliminary analysis indicates the first observation of a sidewards flow signature for A's. Comparisons with the cascade code ARC are made

  10. Generation of reactive oxygen species in the anterior eye segment. Synergistic codrugs of N-acetylcarnosine lubricant eye drops and mitochondria-targeted antioxidant act as a powerful therapeutic platform for the treatment of cataracts and primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Mark A. Babizhayev

    2016-12-01

    Mitochondrial targeting of compounds with universal types of antioxidant activity represents a promising approach for treating a number of ROS-related ocular diseases of the aging eye and can be implicated in the management of cataracts and primary open-angle glaucoma.

  11. Come and see: Opening eyes, minds and dialogue. Taking stock in the fourth year of Swiss NPP advertising

    International Nuclear Information System (INIS)

    Hahlen, Peter

    1999-01-01

    It is now clear that the 'come and see' concept underlying the Swiss NPPs TV advertising campaign, which started in 1995/96, really does work - even over a period of several years. This is not a trivial finding: other, recent, TV and print ad campaigns with more far-reaching nuclear messages (relating to waste management issues) provoked noisy and hostile political reactions. The concept of an extensively regionalised testimonial print ad campaign running 'under the roof' of the national TV campaign works very well. However, it must be stressed that detailed knowledge of social, political and media related situations in the regions addressed is of paramount importance, and approaches have to be carefully adapted to these geographically widely varying conditions. The invitation to dialogue, with its natural openness, is well received by the public and by opinion leaders, in particular by journalists - something which is observed every time the campaign starts in a new region. The aim of the programme, namely to give the Swiss NPPs 'a voice of their own', has been attained, despite a rather moderate budget. The fact that the Swiss NPPs speak out on their own, without reference to their superiors in the economic hierarchy is accepted and even well received by both the media and the public. The principle of devoting at least half the budget to the direct costs of 'placing' TV ads - in order to attain recognition in the face of the prevailing flood of information - has been proved to be the right one. Professional advertising efficiency controls carried out every year since the start of the campaign have confirmed that the NNP TV ads have been 'noticed' by a reasonably high percentage of the public, compared to other TV ads shown at the same time. The budget of 2 million Swiss francs (roughly US$ 27 million) per year, corresponding to almost 1 US dollar per private household or less than half a dollar per capita of the Swiss population, was very tight. The aim of the

  12. Modeling of Liquid Steel/Slag/Argon Gas Multiphase Flow During Tundish Open Eye Formation in a Two-Strand Tundish

    Science.gov (United States)

    Chatterjee, Saikat; Li, Donghui; Chattopadhyay, Kinnor

    2018-04-01

    Multiphase flows are frequently encountered in metallurgical operations. One of the most effective ways to understand these processes is by flow modeling. The process of tundish open eye (TOE) formation involves three-phase interaction between liquid steel, slag, and argon gas. The two-phase interaction involving argon gas bubbles and liquid steel can be modeled relatively easily using the discrete phase modeling technique. However, the effect of an upper slag layer cannot be captured using this approach. The presence of an upper buoyant phase can have a major effect on the behavior of TOEs. Hence, a multiphase model, including three phases, viz. liquid steel, slag, and argon gas, in a two-strand slab caster tundish, was developed to study the formation and evolution of TOEs. The volume of fluid model was used to track the interphase between liquid steel and slag phases, while the discrete phase model was used to trace the movement of the argon gas bubbles in liquid steel. The variation in the TOE areas with different amounts of aspirated argon gas was examined in the presence of an overlying slag phase. The mathematical model predictions were compared against steel plant measurements.

  13. Probing a steep EoS for dark energy with latest observations

    Science.gov (United States)

    Jaber, Mariana; Macorra, Axel de la

    2018-01-01

    We present a parametrization for the Dark Energy Equation of State "EoS" which has a rich structure, performing a transition at pivotal redshift zT between the present day value w0 to an early time wi =wa +w0 ≡ w(z ≫ 0) with a steepness given in terms of q parameter. The proposed parametrization is w =w0 +wa(z /zT) q /(1 +(z /zT)) q , with w0, wi, q and zT constant parameters. It reduces to the widely used EoS w =w0 +wa(1 - a) for zT = q = 1 . This transition is motivated by scalar field dynamics such as for example quintessence models. We study if a late time transition is favored by BAO measurements combined with local determination of H0 and information from the CMB. We find that our dynamical DE model allows to simultaneously fit H0 from local determinations and Planck CMB measurements, alleviating the tension obtained in a ΛCDM model. We obtain a smaller χ2 in our DE model than in ΛCDM showing that a dynamical DE is preferred with a reduction of 4.8%, 20.2% and 42.8% using BAO + H0, BAO + CMB and BAO + CMB + H0 datasets, respectively. However due to the increased number of free parameters in the EoS information criteria favors ΛCDM over our DE model at this stage. Nevertheless it is crucial to obtain the dynamics of DE from the observational data to show the path for theoretical DE models based on fundamental physics.

  14. Mands for Information Using "How" Under EO-Absent and EO-Present Conditions.

    Science.gov (United States)

    Shillingsburg, M Alice; Bowen, Crystal N; Valentino, Amber L

    2014-06-01

    The present study replicates and extends previous research on teaching "How?" mands for information to children with autism. The experimental preparation involved mand training in the context of completing preferred activities and included training and testing under conditions when the establishing operation (EO) was present and absent. Results show that two children with autism acquired mands for information using How? only in situations where information was valuable (i.e., the EO was present); they then consistently made use of the information provided in activity completion. Generalization to novel, untaught situations was assessed.

  15. A nonrandomized, open-label study to evaluate the effect of nasal stimulation on tear production in subjects with dry eye disease

    Directory of Open Access Journals (Sweden)

    Friedman NJ

    2016-05-01

    Full Text Available Neil J Friedman,1 Karla Butron,2 Nora Robledo,2 James Loudin,3 Stephanie N Baba,3 Arturo Chayet2 1Department of Ophthalmology, Stanford University, Mid-Peninsula Ophthalmology Medical Group, Palo Alto, CA, USA; 2Codet Vision Institute, Tijuana, Mexico; 3Oculeve, Inc., South San Francisco, CA, USA Background: Dry eye disease (DED, a chronic disorder affecting the tear film and lacrimal functional unit, is a widely prevalent condition associated with significant burden and unmet treatment needs. Since specific neural circuits play an important role in maintaining ocular surface health, microelectrical stimulation of these pathways could present a promising new approach to treating DED. This study evaluated the efficacy and safety of nasal electrical stimulation in patients with DED. Methods: This prospective, open-label, single-arm, nonrandomized pilot study included 40 patients with mild to severe DED. After undergoing two screening visits, enrolled subjects were provided with a nasal stimulation device and instructed to use it at home four times daily (or more often as needed. Follow-up assessments were conducted up to day 180. The primary efficacy endpoint was the difference between unstimulated and stimulated tear production quantified by Schirmer scores. Additional efficacy endpoints included change from baseline in corneal and conjunctival staining, symptoms evaluated on a Visual Analog Scale, and Ocular Surface Disease Index scores. Safety parameters included adverse event (AE rates, visual acuity, intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, and endoscopic nasal examinations. Results: Mean stimulated Schirmer scores were significantly higher than the unstimulated scores at all visits, and corneal and conjunctival staining and symptom scores from baseline to day 180 were significantly reduced. No serious device-related AEs and nine nonserious AEs (three device-related were reported. Intraocular pressure remained

  16. EO-1 analysis applicable to coastal characterization

    Science.gov (United States)

    Burke, Hsiao-hua K.; Misra, Bijoy; Hsu, Su May; Griffin, Michael K.; Upham, Carolyn; Farrar, Kris

    2003-09-01

    The EO-1 satellite is part of NASA's New Millennium Program (NMP). It consists of three imaging sensors: the multi-spectral Advanced Land Imager (ALI), Hyperion and Atmospheric Corrector. Hyperion provides a high-resolution hyperspectral imager capable of resolving 220 spectral bands (from 0.4 to 2.5 micron) with a 30 m resolution. The instrument images a 7.5 km by 100 km land area per image. Hyperion is currently the only space-borne HSI data source since the launch of EO-1 in late 2000. The discussion begins with the unique capability of hyperspectral sensing to coastal characterization: (1) most ocean feature algorithms are semi-empirical retrievals and HSI has all spectral bands to provide legacy with previous sensors and to explore new information, (2) coastal features are more complex than those of deep ocean that coupled effects are best resolved with HSI, and (3) with contiguous spectral coverage, atmospheric compensation can be done with more accuracy and confidence, especially since atmospheric aerosol effects are the most pronounced in the visible region where coastal feature lie. EO-1 data from Chesapeake Bay from 19 February 2002 are analyzed. In this presentation, it is first illustrated that hyperspectral data inherently provide more information for feature extraction than multispectral data despite Hyperion has lower SNR than ALI. Chlorophyll retrievals are also shown. The results compare favorably with data from other sources. The analysis illustrates the potential value of Hyperion (and HSI in general) data to coastal characterization. Future measurement requirements (air borne and space borne) are also discussed.

  17. Share Your Opinion With Other Eos Readers

    Science.gov (United States)

    Narasimhan, T. N.

    2006-11-01

    Earlier this year, Robert Kitchen (Eos, 87(24), 235, 2006) drew attention to declining interest in Earth science education in public schools. The reason for a lack of interest in teaching Earth sciences in public schools may involve more than just the attitudes of parents who may wish for their children a better preparation for advanced placement courses later on. Part of the problem may lie with our present mind-set that technology can solve all the world's problems, from poverty, to better health, and to prosperity.

  18. New RADIOM algorithm using inverse EOS

    Science.gov (United States)

    Busquet, Michel; Sokolov, Igor; Klapisch, Marcel

    2012-10-01

    The RADIOM model, [1-2], allows one to implement non-LTE atomic physics with a very low extra CPU cost. Although originally heuristic, RADIOM has been physically justified [3] and some accounting for auto-ionization has been included [2]. RADIOM defines an ionization temperature Tz derived from electronic density and actual electronic temperature Te. LTE databases are then queried for properties at Tz and NLTE values are derived from them. Some hydro-codes (like FAST at NRL, Ramis' MULTI, or the CRASH code at U.Mich) use inverse EOS starting from the total internal energy Etot and returning the temperature. In the NLTE case, inverse EOS requires to solve implicit relations between Te, Tz, and Etot. We shall describe these relations and an efficient solver successively implemented in some of our codes. [4pt] [1] M. Busquet, Radiation dependent ionization model for laser-created plasmas, Ph. Fluids B 5, 4191 (1993).[0pt] [2] M. Busquet, D. Colombant, M. Klapisch, D. Fyfe, J. Gardner. Improvements to the RADIOM non-LTE model, HEDP 5, 270 (2009).[0pt] [3] M.Busquet, Onset of pseudo-thermal equilibrium within configurations and super-configurations, JQSRT 99, 131 (2006)

  19. Meta-analysis of the efficacy and safety of combined surgery in the management of eyes with coexisting cataract and open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Nan Jiang

    2018-02-01

    Full Text Available AIM: To conduct a systematic review and quantitative Meta-analysis of the efficacy and safety of combined surgery for the eyes with coexisting cataract and open angle glaucoma. METHODS: We performed a systematic search of the related literature in the Cochrane Library, PubMed, EMBASE, Web of Science databases, CNKI, CBM and Wan Fang databases, with no limitations on language or publication date. The primary efficacy estimate was identified by weighted mean difference of the percentage of intraocular pressure reduction (IOPR% from baseline to end-point, the percentage of number of glaucoma medications reduction from pre- to post-operation, and the secondary efficacy evaluations were performed by odds ratio (OR and 95% confidence interval (CI for complete and qualified success rate. Besides, ORs were applied to assess the tolerability of adverse incidents. Meta-analyses of fixed or random effect models were performed using RevMan software 5.2 to gather the consequences. Heterogeneity was evaluated by Chi2 test and the I2 measure. RESULTS: Ten studies enrolling 3108 patients were included. The combined consequences indicated that both glaucoma and combined cataract and glaucoma surgery significantly decreased IOP. For deep sclerectomy vs deep sclerectomy plus phacoemulsification and canaloplasty vs phaco-canaloplasty, the differences in IOPR% were not all statistically significant while trabeculotomy was detected to gain a quantitatively greater IOPR% compared with trabeculotomy plus phacoemulsification. Furthermore, there was no statistical significance in the complete and qualified success rate, and the rates of adverse incidents for trabeculotomy vs trabeculotomy plus phacoemulsification. CONCLUSION: Compared with trabeculotomy plus phacoemulsification, trabeculectomy alone is more effective in lowering IOP and the number of glaucoma medications, while the two surgeries can not demonstrate statistical differences in the complete success rate

  20. Meta-analysis of the efficacy and safety of combined surgery in the management of eyes with coexisting cataract and open angle glaucoma.

    Science.gov (United States)

    Jiang, Nan; Zhao, Gui-Qiu; Lin, Jing; Hu, Li-Ting; Che, Cheng-Ye; Wang, Qian; Xu, Qiang; Li, Cui; Zhang, Jie

    2018-01-01

    To conduct a systematic review and quantitative Meta-analysis of the efficacy and safety of combined surgery for the eyes with coexisting cataract and open angle glaucoma. We performed a systematic search of the related literature in the Cochrane Library, PubMed, EMBASE, Web of Science databases, CNKI, CBM and Wan Fang databases, with no limitations on language or publication date. The primary efficacy estimate was identified by weighted mean difference of the percentage of intraocular pressure reduction (IOPR%) from baseline to end-point, the percentage of number of glaucoma medications reduction from pre- to post-operation, and the secondary efficacy evaluations were performed by odds ratio (OR) and 95% confidence interval (CI) for complete and qualified success rate. Besides, ORs were applied to assess the tolerability of adverse incidents. Meta-analyses of fixed or random effect models were performed using RevMan software 5.2 to gather the consequences. Heterogeneity was evaluated by Chi 2 test and the I 2 measure. Ten studies enrolling 3108 patients were included. The combined consequences indicated that both glaucoma and combined cataract and glaucoma surgery significantly decreased IOP. For deep sclerectomy vs deep sclerectomy plus phacoemulsification and canaloplasty vs phaco-canaloplasty, the differences in IOPR% were not all statistically significant while trabeculotomy was detected to gain a quantitatively greater IOPR% compared with trabeculotomy plus phacoemulsification. Furthermore, there was no statistical significance in the complete and qualified success rate, and the rates of adverse incidents for trabeculotomy vs trabeculotomy plus phacoemulsification. Compared with trabeculotomy plus phacoemulsification, trabeculectomy alone is more effective in lowering IOP and the number of glaucoma medications, while the two surgeries can not demonstrate statistical differences in the complete success rate, qualified success rate, or incidence of adverse

  1. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  2. The ASY-EOS Experiment at GSI

    Directory of Open Access Journals (Sweden)

    Russotto P.

    2016-01-01

    Full Text Available The elliptic-flow ratio of neutrons with respect to protons or light complex particles in reactions of heavy ions at pre-relativistic energies has been proposed as an observable sensitive to the strength of the symmetry term of the nuclear equation of state at supra-saturation densities. In the ASY-EOS experiment at the GSI laboratory, flows of neutrons and light charged particles were measured for 197Au+197Au collisions at 400 MeV/nucleon. Flow results obtained for the Au+Au system, in comparison with predictions of the UrQMD transport model, confirm the moderately soft to linear density dependence of the symmetry energy deduced from the earlier FOPI-LAND data.

  3. EO system concepts in the littoral

    Science.gov (United States)

    Schwering, Piet B. W.; van den Broek, Sebastiaan P.; van Iersel, Miranda

    2007-04-01

    In recent years, operations executed by naval forces have taken place at many different locations. At present, operations against international terrorism and asymmetric warfare in coastal environments are of major concern. In these scenarios, the threat caused by pirates on-board of small surface targets, such as jetskis and fast inshore attack crafts, is increasing. In the littoral environment, the understanding of its complexity and the efficient use of the limited reaction time, are essential for successful operations. Present-day electro-optical sensor suites, also incorporating Infrared Search and Track systems, can be used for varying tasks as detection, classification and identification. By means of passive electro-optical systems, infrared and visible light sensors, improved situational awareness can be achieved. For long range capability, elevated sensor masts and flying platforms are ideally suited for the surveillance task and improve situational awareness. A primary issue is how to incorporate new electro-optical technology and signal processing into the new sensor concepts, to improve system performance. It is essential to derive accurate information from the high spatial-resolution imagery created by the EO sensors. As electro-optical sensors do not have all-weather capability, the performance degradation in adverse scenarios must be understood, in order to support the operational use of adaptive sensor management techniques. In this paper we discuss the approach taken at TNO in the design and assessment of system concepts for future IRST development. An overview of our maritime programme in future IRST and EO system concepts including signal processing is presented.

  4. Supernova constraints on neutrino oscillation and EoS for proto-neutron star

    Energy Technology Data Exchange (ETDEWEB)

    Kajino, T. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588, Japan and Department of Astronomy, University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-0033 (Japan); Aoki, W. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Cheoun, M.-K. [Department of Physics, Soongsil University, Seoul 156-743 (Korea, Republic of); Hayakawa, T. [Japan Atomic Energy Agency, Shirakara-Shirane 2-4, Tokai-mura, Ibaraki 319-1195 (Japan); Hidaka, J. [National Astronomical Observatory, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Hirai, Y.; Shibagaki, S. [National Astronomical Observatory, 2-21-1 Osawa, Mitaka, Tokyo 181-8588, Japan and Department of Astronomy, University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-0033 (Japan); Mathews, G. J. [Department of Physics, University of Notre Dame, IN 46556 (United States); Nakamura, K. [Waseda University, Ohkubo 3-4-1, Shinjuku, Tokyo 169-8555 (Japan); Suzuki, T. [Nihon University, Sakurajosui 3-25-40, Setagaya-ku, Tokyo 156-8550 (Japan)

    2014-05-02

    Core-collapse supernovae eject huge amount of flux of energetic neutrinos which affect explosive nucleosynthesis of rare isotopes like {sup 7}Li, {sup 11}B, {sup 92}Nb, {sup 138}La and Ta and r-process elements. Several isotopes depend strongly on the neutrino flavor oscillation due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. We here discuss how to determine the neutrino temperatures and propose a method to determine still unknown neutrino oscillation parameters, mass hierarchy and θ{sub 13}, simultaneously. Combining the recent experimental constraints on θ{sub 13} with isotopic ratios of the light elements discovered in presolar grains from the Murchison meteorite, we show that our method suggests at a marginal preference for an inverted neutrino mass hierarchy. We also discuss supernova relic neutrinos that may indicate the softness of the equation of state (EoS) of nuclear matter as well as adiabatic conditions of the neutrino oscillation.

  5. Supernova constraints on neutrino oscillation and EoS for proto-neutron star

    Science.gov (United States)

    Kajino, T.; Aoki, W.; Cheoun, M.-K.; Hayakawa, T.; Hidaka, J.; Hirai, Y.; Mathews, G. J.; Nakamura, K.; Shibagaki, S.; Suzuki, T.

    2014-05-01

    Core-collapse supernovae eject huge amount of flux of energetic neutrinos which affect explosive nucleosynthesis of rare isotopes like 7Li, 11B, 92Nb, 138La and Ta and r-process elements. Several isotopes depend strongly on the neutrino flavor oscillation due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. We here discuss how to determine the neutrino temperatures and propose a method to determine still unknown neutrino oscillation parameters, mass hierarchy and θ13, simultaneously. Combining the recent experimental constraints on θ13 with isotopic ratios of the light elements discovered in presolar grains from the Murchison meteorite, we show that our method suggests at a marginal preference for an inverted neutrino mass hierarchy. We also discuss supernova relic neutrinos that may indicate the softness of the equation of state (EoS) of nuclear matter as well as adiabatic conditions of the neutrino oscillation.

  6. Analytic EoS and PTW strength model recommendation for Starck Ta

    Energy Technology Data Exchange (ETDEWEB)

    Sjue, Sky K. [Los Alamos National Laboratory; Prime, Michael Bruce [Los Alamos National Laboratory

    2016-09-01

    The purpose of this document is to provide an analytic EoS and PTW strength model for Starck Ta that can be consistently used between different platforms and simulations at three labs. This should provide a consistent basis for comparison of the results of calculations, but not the best implementation for matching a wide variety of experimental data. Another version using SESAME tables should follow, which will provide a better physical representation over a broader range of conditions. The data sets available at the time only include one Hopkinson bar at a strain rate of 1800/s; a broader range of high-rate calibration data would be preferred. The resulting fit gives the PTW parameter p = 0. To avoid numerical issues, p = 0:001 has been used in FLAG. The PTW parameters that apply above the maximum strain rate in the data use the values from the original publication.

  7. Eos a Universal Verifiable and Coercion Resistant Voting Protocol

    DEFF Research Database (Denmark)

    Patachi, Stefan; Schürmann, Carsten

    2017-01-01

    Authority. Eos uses two mixing phases with the goal to break the connection between the voter and vote, not to preserve vote privacy (which is given already) but to guarantee coercion resistance by making it (nearly) impossible for a coercer to follow their vote through the bulletin board. Eos...

  8. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  9. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  10. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  11. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  12. Patient-family EoL communication and its predictors: Reports from caregivers of Latino patients in the rural U.S.-Mexico border region.

    Science.gov (United States)

    Ko, Eunjeong; Lee, Jaehoon; Ramirez, Carlos; Lopez, Denicka; Martinez, Stephanie

    2017-10-26

    Family caregivers play an important role in end-of-life (EoL) decision making when the patient is unable to make his/her own decisions. While communication about EoL care between patients and family is perhaps a first step toward advance care planning (ACP)/EoL decisions, not every culture puts great value on open communication about this topic. The aims of the present study were to explore EoL communication and the aspects of communication among caregivers of Latino patients in the rural United States (U.S.)-Mexico border region. This study analyzed data from a hospice needs assessment collected from 189 family caregivers of Latino patients at a home health agency in a rural U.S.-Mexico border region. Bivariate tests and logistic regression were used to address our aims. About half of the family caregivers (n = 96, 50.8%) reported to have ever engaged in EoL discussion with patients. Significant predictors of EoL discussion included life-sustaining treatment preference (odds ratio [OR] = 0.44, p EoL communication. Also, caregivers who worried that physicians might want to stop treatments (i.e., "pull the plug") too soon were less likely to do so. Conversely, caregivers who had knowledge about ADs were more likely to engage in EoL communication. EoL communication is a complex process influenced by individual, social, and cultural values and the beliefs of both the patient and his/her family. Inclusion of family caregivers in the ACP process and facilitating culturally tailored EoL communication between patients and family caregivers is important.

  13. Ocular health among radiologists in the age of PACS: is it time for our profession to open its eyes to this issue in light of existing European legislation?

    LENUS (Irish Health Repository)

    Halpenny, D

    2012-12-01

    The regular use of visual display units (VDUs) at work has been shown to cause the development of a constellation of symptoms ranging from dry eyes to temporary myopia. European workers who use VDUs are now protected under detailed legislation enacted by the European Union (Directive 90\\/270\\/EEC). The use of picture archiving and communications systems, which are almost ubiquitous in European countries, means that, as a profession, radiologists fall under the remit of this legislation. This paper aims to assess the impact that full implementation of this law would have on a radiologist\\'s practice and to more broadly examine the issue of eye care as an occupational health issue in radiology. The authors conclude that eye care in the setting of regular VDU use among radiologists is an important quality control and occupational health issue. There is a clear legal basis requiring employers to provide regular eye examinations and reporting breaks. In the absence of leadership from employers on this issue individual radiologists have a responsibility to ensure that their work practices reflect the legal situation and minimise the effect of eye strain on their performance.

  14. EOS Data Products Latency and Reprocessing Evaluation

    Science.gov (United States)

    Ramapriyan, H. K.; Wanchoo, L.

    2012-12-01

    NASA's Earth Observing System (EOS) Data and Information System (EOSDIS) program has been processing, archiving, and distributing EOS data since the launch of Terra platform in 1999. The EOSDIS Distributed Active Archive Centers (DAACs) and Science-Investigator-led Processing Systems (SIPSs) are generating over 5000 unique products with a daily average volume of 1.7 Petabytes. Initially EOSDIS had requirements to make process data products within 24 hours of receiving all inputs needed for generating them. Thus, generally, the latency would be slightly over 24 and 48 hours after satellite data acquisition, respectively, for Level 1 and Level 2 products. Due to budgetary constraints these requirements were relaxed, with the requirement being to avoid a growing backlog of unprocessed data. However, the data providers have been generating these products in as timely a manner as possible. The reduction in costs of computing hardware has helped considerably. It is of interest to analyze the actual latencies achieved over the past several years in processing and inserting the data products into the EOSDIS archives for the users to support various scientific studies such as land processes, oceanography, hydrology, atmospheric science, cryospheric science, etc. The instrument science teams have continuously evaluated the data products since the launches of EOS satellites and improved the science algorithms to provide high quality products. Data providers have periodically reprocessed the previously acquired data with these improved algorithms. The reprocessing campaigns run for an extended time period in parallel with forward processing, since all data starting from the beginning of the mission need to be reprocessed. Each reprocessing activity involves more data than the previous reprocessing. The historical record of the reprocessing times would be of interest to future missions, especially those involving large volumes of data and/or computational loads due to

  15. Web Monitoring of EOS Front-End Ground Operations, Science Downlinks and Level 0 Processing

    Science.gov (United States)

    Cordier, Guy R.; Wilkinson, Chris; McLemore, Bruce

    2008-01-01

    This paper addresses the efforts undertaken and the technology deployed to aggregate and distribute the metadata characterizing the real-time operations associated with NASA Earth Observing Systems (EOS) high-rate front-end systems and the science data collected at multiple ground stations and forwarded to the Goddard Space Flight Center for level 0 processing. Station operators, mission project management personnel, spacecraft flight operations personnel and data end-users for various EOS missions can retrieve the information at any time from any location having access to the internet. The users are distributed and the EOS systems are distributed but the centralized metadata accessed via an external web server provide an effective global and detailed view of the enterprise-wide events as they are happening. The data-driven architecture and the implementation of applied middleware technology, open source database, open source monitoring tools, and external web server converge nicely to fulfill the various needs of the enterprise. The timeliness and content of the information provided are key to making timely and correct decisions which reduce project risk and enhance overall customer satisfaction. The authors discuss security measures employed to limit access of data to authorized users only.

  16. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  17. Processing EOS MLS Level-2 Data

    Science.gov (United States)

    Snyder, W. Van; Wu, Dong; Read, William; Jiang, Jonathan; Wagner, Paul; Livesey, Nathaniel; Schwartz, Michael; Filipiak, Mark; Pumphrey, Hugh; Shippony, Zvi

    2006-01-01

    A computer program performs level-2 processing of thermal-microwave-radiance data from observations of the limb of the Earth by the Earth Observing System (EOS) Microwave Limb Sounder (MLS). The purpose of the processing is to estimate the composition and temperature of the atmosphere versus altitude from .8 to .90 km. "Level-2" as used here is a specialists f term signifying both vertical profiles of geophysical parameters along the measurement track of the instrument and processing performed by this or other software to generate such profiles. Designed to be flexible, the program is controlled via a configuration file that defines all aspects of processing, including contents of state and measurement vectors, configurations of forward models, measurement and calibration data to be read, and the manner of inverting the models to obtain the desired estimates. The program can operate in a parallel form in which one instance of the program acts a master, coordinating the work of multiple slave instances on a cluster of computers, each slave operating on a portion of the data. Optionally, the configuration file can be made to instruct the software to produce files of simulated radiances based on state vectors formed from sets of geophysical data-product files taken as input.

  18. The Earth Observing System (EOS) Ground System: Leveraging an Existing Operational Ground System Infrastructure to Support New Missions

    Science.gov (United States)

    Hardison, David; Medina, Johnny; Dell, Greg

    2016-01-01

    The Earth Observer System (EOS) was officially established in 1990 and went operational in December 1999 with the launch of its flagship spacecraft Terra. Aqua followed in 2002 and Aura in 2004. All three spacecraft are still operational and producing valuable scientific data. While all are beyond their original design lifetime, they are expected to remain viable well into the 2020s. The EOS Ground System is a multi-mission system based at NASA Goddard Space Flight Center that supports science and spacecraft operations for these three missions. Over its operational lifetime to date, the EOS Ground System has evolved as needed to accommodate mission requirements. With an eye towards the future, several updates are currently being deployed. Subsystem interconnects are being upgraded to reduce data latency and improve system performance. End-of-life hardware and operating systems are being replaced to mitigate security concerns and eliminate vendor support gaps. Subsystem hardware is being consolidated through the migration to Virtual Machine based platforms. While mission operations autonomy was not a design goal of the original system concept, there is an active effort to apply state-of-the-art products from the Goddard Mission Services Evolution Center (GMSEC) to facilitate automation where possible within the existing heritage architecture. This presentation will provide background information on the EOS ground system architecture and evolution, discuss latest improvements, and conclude with the results of a recent effort that investigated how the current system could accommodate a proposed new earth science mission.

  19. The Earth Observing System (EOS) nickel-hydrogen battery

    Science.gov (United States)

    Bennett, Charles W.

    1992-01-01

    Information is given in viewgraph form on the Earth Observing System (EOS) nickel hydrogen battery. Information is given on the life evaluation test, cell characteristics, acceptance and characterization tests, and the battery system description.

  20. XML DTD and Schemas for HDF-EOS

    Science.gov (United States)

    Ullman, Richard; Yang, Jingli

    2008-01-01

    An Extensible Markup Language (XML) document type definition (DTD) standard for the structure and contents of HDF-EOS files and their contents, and an equivalent standard in the form of schemas, have been developed.

  1. Energy Referencing in LANL HE-EOS Codes

    Energy Technology Data Exchange (ETDEWEB)

    Leiding, Jeffery Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Coe, Joshua Damon [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-19

    Here, We briefly describe the choice of energy referencing in LANL's HE-EOS codes, HEOS and MAGPIE. Understanding this is essential to comparing energies produced by different EOS codes, as well as to the correct calculation of shock Hugoniots of HEs and other materials. In all equations after (3) throughout this report, all energies, enthalpies and volumes are assumed to be molar quantities.

  2. Earth Observation for Biodiversity Assessment (EO-BA)

    CSIR Research Space (South Africa)

    Cho, Moses A

    2012-10-01

    Full Text Available in the Dukuduku coastal forest Earth Observation for Biodiversity Assessment (EO-BA) MA CHO, P DEBBA, R MATHIEU, A RAMOELO, L NAIDOO, H VAN DEVENTER, O MALAHLELA AND R MAIN CSIR Natural Resources and the Environment, Pretoria, South Africa PO Box 395... Observation for Biodiversity Assessment (EO-BA) programme is designed to enhance biodiversity assessment and conservation through the application of earth observation data, with particular focus on the African continent. MISSION To initiate and develop...

  3. EOS7R: Radionuclide transport for TOUGH2

    International Nuclear Information System (INIS)

    Oldenburg, C.M.; Pruess, K.

    1995-11-01

    EOS7R provides radionuclide transport capability for TOUGH2. EOS7R extends the EOS7 module (water, brine, and optional air) to model water, brine, parent component, daughter component, and optional air and heat. The radionuclide components follow a first-order decay law, and may adsorb onto the solid grains. Volatilization of the decaying components is modeled by Henry's Law. The decaying components are normally referred to as radionuclides, but they may in fact by any trace components that decay, adsorb, and volatilize. The decay process need not be radioactive decay, but could be any process that follows a first-order decay law, such as biodegradation. EOS7R includes molecular diffusion for all components in gaseous and aqueous phases using a simplified binary diffusion model. When EOS7R is used with standard TOUGH2, transport occurs by advection and molecular diffusion in all phases. When EOS7R is coupled with the dispersion module T2DM, one obtains T2DMR, the radionuclide transport version of T2DM. T2DMR models advection, diffusion, and hydrodynamic dispersion in rectangular two-dimensional regions. Modeling of radionuclide transport requires input parameters specifying the half-life for first-order decay, distribution coefficients for each rock type for adsorption, and inverse Henry's constants for volatilization. Options can be specified in the input file to model decay in inactive grid blocks and to read from standard EOS7 INCON files. The authors present a number of example problems to demonstrate application and accuracy of TOUGH2/EOS7R. One-dimensional simulation results agree well with analytical solutions. For a two-dimensional salt-dome flow problem, the final distribution of daughter radionuclide component is complicated by the presence of weak recirculation caused by density effects due to salinity

  4. EOS as the present and future solution for data storage at CERN

    CERN Document Server

    Peters, AJ; Adde, G

    2015-01-01

    EOS is an open source distributed disk storage system in production since 2011 at CERN. Development focus has been on low-latency analysis use cases for LHC(1) and non- LHC experiments and life-cycle management using JBOD(2) hardware for multi PB storage installations. The EOS design implies a split of hot and cold storage and introduced a change of the traditional HSM(3) functionality based workflows at CERN.The 2015 deployment brings storage at CERN to a new scale and foresees to breach 100 PB of disk storage in a distributed environment using tens of thousands of (heterogeneous) hard drives. EOS has brought to CERN major improvements compared to past storage solutions by allowing quick changes in the quality of service of the storage pools. This allows the data centre to quickly meet the changing performance and reliability requirements of the LHC experiments with minimal data movements and dynamic reconfiguration. For example, the software stack has met the specific needs of the dual computing centre set-...

  5. Short-term effect of latanoprost and timolol eye drops on tear fluid and the ocular surface in patients with primary open-angle glaucoma and ocular hypertension

    DEFF Research Database (Denmark)

    Thygesen, John; Aaen, Kim; Theodorsen, F.

    2000-01-01

    ophthalmology, open-angle glaucoma, ocular hypertension, glaucoma therapy, latanoprost, timolol, Rose-Bengal test, break-up time, Schirmer-1-test, conjunctival impression cytology......ophthalmology, open-angle glaucoma, ocular hypertension, glaucoma therapy, latanoprost, timolol, Rose-Bengal test, break-up time, Schirmer-1-test, conjunctival impression cytology...

  6. Building EOS capability for Malaysia – the options

    International Nuclear Information System (INIS)

    Subari, M D; Hassan, A

    2014-01-01

    Earth observation satellite (EOS) is currently a major tool to monitor earth dynamics and increase human understanding of earth surface process. Since the early 80s, Malaysia has been using EOS images for various applications, such as weather forecasting, land use mapping, agriculture, environment monitoring and others. Until now, all EOS images were obtained from foreign satellite systems. Realising on the strategic need of having its own capability, Malaysia embarked into EOS development programs in the early 90s. Starting with TiungSAT-1, a micro-satellite carrying small camera, then followed by RazakSAT, a small satellite carrying 2.5 m panchromatic (PAN) medium-aperture-camera, the current satellite program development, the RazakSAT-2, designed to carry a 1.0 m high resolution PAN and 4.0m multi-spectral camera, would become a strategic initiative of the government in developing and accelerating the nation's capability in the area of satellite technology and its application. Would this effort continue until all needs of the remote sensing community being fulfilled by its own EOS? This paper will analyze the intention of the Malaysian government through its National Space Policy and other related policy documents, and proposes some policy options on this. Key factors to be considered are specific data need of the EOS community, data availability and the more subjective political motivations such as national pride

  7. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  8. Enhanced EOS photovoltaic power system capability with InP solar cells

    Science.gov (United States)

    Bailey, Sheila G.; Weinberg, Irving; Flood, Dennis J.

    1991-01-01

    The Earth Observing System (EOS), which is part of the International Mission to Planet Earth, is NASA's main contribution to the Global Change Research Program which opens a new era in international cooperation to study the Earth's environment. Five large platforms are to be launched into polar orbit, two by NASA, two by ESA, and one by the Japanese. In such an orbit the radiation resistance of indium phosphide solar cells combined with the potential of utilizing five micron cell structures yields an increase of 10 percent in the payload capability. If further combined with the advanced photovoltaic solar array the payload savings approaches 12 percent.

  9. 76 FR 70927 - USACE's Plan for Retrospective Review Under E.O. 13563

    Science.gov (United States)

    2011-11-16

    ... for Retrospective Review Under E.O. 13563 AGENCY: U.S. Army Corps of Engineers, DoD. ACTION: Notice of...'' (E.O.), issued on January 18, 2011, directs Federal agencies to review existing significant... they are a significant rule warranting review pursuant to E.O. 13563. The E.O. further directs each...

  10. EOS Reference Handbook 1999: A Guide to NASA's Earth Science Enterprise and the Earth Observing System

    Science.gov (United States)

    King, M. D. (Editor); Greenstone, R. (Editor)

    2000-01-01

    The content of this handbook includes Earth Science Enterprise; The Earth Observing System; EOS Data and Information System (EOSDIS); Data and Information Policy; Pathfinder Data Sets; Earth Science Information Partners and the Working Prototype-Federation; EOS Data Quality: Calibration and Validation; Education Programs; International Cooperation; Interagency Coordination; Mission Elements; EOS Instruments; EOS Interdisciplinary Science Investigations; and Points-of-Contact.

  11. Exponential 6 parameterization for the JCZ3-EOS

    Energy Technology Data Exchange (ETDEWEB)

    McGee, B.C.; Hobbs, M.L.; Baer, M.R.

    1998-07-01

    A database has been created for use with the Jacobs-Cowperthwaite-Zwisler-3 equation-of-state (JCZ3-EOS) to determine thermochemical equilibrium for detonation and expansion states of energetic materials. The JCZ3-EOS uses the exponential 6 intermolecular potential function to describe interactions between molecules. All product species are characterized by r*, the radius of the minimum pair potential energy, and {var_epsilon}/k, the well depth energy normalized by Boltzmann`s constant. These parameters constitute the JCZS (S for Sandia) EOS database describing 750 gases (including all the gases in the JANNAF tables), and have been obtained by using Lennard-Jones potential parameters, a corresponding states theory, pure liquid shock Hugoniot data, and fit values using an empirical EOS. This database can be used with the CHEETAH 1.40 or CHEETAH 2.0 interface to the TIGER computer program that predicts the equilibrium state of gas- and condensed-phase product species. The large JCZS-EOS database permits intermolecular potential based equilibrium calculations of energetic materials with complex elemental composition.

  12. Lamina cribrosa position and Bruch's membrane opening differences between anterior ischemic optic neuropathy and open-angle glaucoma.

    Science.gov (United States)

    Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J

    2018-06-01

    To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.

  13. Eye Injuries

    Science.gov (United States)

    ... that you could lose your vision. Most eye injuries are preventable. If you play sports or work in certain jobs, you may need protection. The most common type of injury happens when something irritates the ...

  14. Eyes - bulging

    Science.gov (United States)

    ... different ages. In: Lambert SR, Lyons CJ, eds. Taylor and Hoyt's Pediatric Ophthalmology and Strabismus . 5th ed. Philadelphia, PA: Elsevier; 2017:chap 96. Orge FH, Grigorian F. Examination and common problems of the neonatal eye. ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  17. PyGaze: an open-source, cross-platform toolbox for minimal-effort programming of eye-tracking experiments

    NARCIS (Netherlands)

    Dalmaijer, E.S.; Mathôt, S.; van der Stigchel, S.

    2014-01-01

    he PyGaze toolbox is an open-source software package for Python, a high-level programming language. It is designed for creating eyetracking experiments in Python syntax with the least possible effort, and it offers programming ease and script readability without constraining functionality and

  18. Results from the MWA EoR Experiment

    Science.gov (United States)

    Webster, Rachel L.; MWA EoR Collaboration

    2018-05-01

    The MWA EoR is one of a small handful of experiments designed to detect the statistical signal from the Epoch of Reionisation. Each of these experiments has reached a level of maturity, where the challenges, in particular of foreground removal, are being more fully understood. Over the past decade, the MWA EoR Collaboration has developed expertise and an understanding of the elements of the telescope array, the end-to-end pipelines, ionospheric conditions, and and the foreground emissions. Sufficient data has been collected to detect the theoretically predicted EoR signal. Limits have been published regularly, however we still several orders of magnitude from a possible detection. This paper outlines recent progress and indicates directions for future efforts.

  19. Mission operations concepts for Earth Observing System (EOS)

    Science.gov (United States)

    Kelly, Angelita C.; Taylor, Thomas D.; Hawkins, Frederick J.

    1991-01-01

    Mission operation concepts are described which are being used to evaluate and influence space and ground system designs and architectures with the goal of achieving successful, efficient, and cost-effective Earth Observing System (EOS) operations. Emphasis is given to the general characteristics and concepts developed for the EOS Space Measurement System, which uses a new series of polar-orbiting observatories. Data rates are given for various instruments. Some of the operations concepts which require a total system view are also examined, including command operations, data processing, data accountability, data archival, prelaunch testing and readiness, launch, performance monitoring and assessment, contingency operations, flight software maintenance, and security.

  20. Report of the EOS oceans panel to the payload panel

    Science.gov (United States)

    Abbott, Mark R.; Freilich, Michael H.

    1992-11-01

    The atmosphere and the ocean are the two great fluids of the earth system. Changes in the coupling of these two fluids will have a profound impact on the Earth's climate and biogeochemical systems. Although changes in atmospheric composition and dynamics are the usual focus of global climate models, it is apparent that the ocean plays a critical role in modulating the magnitude and rate of these changes. The ocean is responsible for nearly half of the poleward heat flux as well as for a significant portion of the uptake of atmospheric carbon dioxide. However, the processes governing the flux of materials and energy between the ocean atmosphere are poorly understood. Such processes include not only physical and chemical dynamics, but also biological processes which act to modify the chemical composition of the ocean as well as the trapping of solar energy as heat in the upper water column. Thus it is essential that the ocean be studied as a complete system of physical, chemical, and biological processes. Overlapping measurements must be made for at least 10-15 years to resolve critical low frequency fluctuations. The present EOS plan relies heavily on non-EOS entities to provide critical data sets for ocean studies. Although such partnerships are usually beneficial, there are risks that must be considered in terms of data coverage, quality, resolution, and availability. A simple replacement of an EOS sensor with a non-EOS sensor based on the fact that they both measure the same quantities will not guarantee that critical measurements will be made to address IPCC priorities in the area of ocean processes. EOS must continue to pursue appropriate methods to ensure that such partner — provided measurements meet scientific requirements. Such methods are analogous to contigencies applied in the area of schedules, cost, and performance for instrument projects. EOS must foster strong ties between US scientists and their foreign counterparts, in order to develop

  1. Eyes of Things

    Directory of Open Access Journals (Sweden)

    Oscar Deniz

    2017-05-01

    Full Text Available Embedded systems control and monitor a great deal of our reality. While some “classic” features are intrinsically necessary, such as low power consumption, rugged operating ranges, fast response and low cost, these systems have evolved in the last few years to emphasize connectivity functions, thus contributing to the Internet of Things paradigm. A myriad of sensing/computing devices are being attached to everyday objects, each able to send and receive data and to act as a unique node in the Internet. Apart from the obvious necessity to process at least some data at the edge (to increase security and reduce power consumption and latency, a major breakthrough will arguably come when such devices are endowed with some level of autonomous “intelligence”. Intelligent computing aims to solve problems for which no efficient exact algorithm can exist or for which we cannot conceive an exact algorithm. Central to such intelligence is Computer Vision (CV, i.e., extracting meaning from images and video. While not everything needs CV, visual information is the richest source of information about the real world: people, places and things. The possibilities of embedded CV are endless if we consider new applications and technologies, such as deep learning, drones, home robotics, intelligent surveillance, intelligent toys, wearable cameras, etc. This paper describes the Eyes of Things (EoT platform, a versatile computer vision platform tackling those challenges and opportunities.

  2. Eyes of Things.

    Science.gov (United States)

    Deniz, Oscar; Vallez, Noelia; Espinosa-Aranda, Jose L; Rico-Saavedra, Jose M; Parra-Patino, Javier; Bueno, Gloria; Moloney, David; Dehghani, Alireza; Dunne, Aubrey; Pagani, Alain; Krauss, Stephan; Reiser, Ruben; Waeny, Martin; Sorci, Matteo; Llewellynn, Tim; Fedorczak, Christian; Larmoire, Thierry; Herbst, Marco; Seirafi, Andre; Seirafi, Kasra

    2017-05-21

    Embedded systems control and monitor a great deal of our reality. While some "classic" features are intrinsically necessary, such as low power consumption, rugged operating ranges, fast response and low cost, these systems have evolved in the last few years to emphasize connectivity functions, thus contributing to the Internet of Things paradigm. A myriad of sensing/computing devices are being attached to everyday objects, each able to send and receive data and to act as a unique node in the Internet. Apart from the obvious necessity to process at least some data at the edge (to increase security and reduce power consumption and latency), a major breakthrough will arguably come when such devices are endowed with some level of autonomous "intelligence". Intelligent computing aims to solve problems for which no efficient exact algorithm can exist or for which we cannot conceive an exact algorithm. Central to such intelligence is Computer Vision (CV), i.e., extracting meaning from images and video. While not everything needs CV, visual information is the richest source of information about the real world: people, places and things. The possibilities of embedded CV are endless if we consider new applications and technologies, such as deep learning, drones, home robotics, intelligent surveillance, intelligent toys, wearable cameras, etc. This paper describes the Eyes of Things (EoT) platform, a versatile computer vision platform tackling those challenges and opportunities.

  3. Internet-delivered eye movement desensitization and reprocessing (iEMDR: an open trial [v2; ref status: indexed, http://f1000r.es/zr

    Directory of Open Access Journals (Sweden)

    Jay Spence

    2013-05-01

    Full Text Available Recent research indicates internet-delivered cognitive behavioural therapy (iCBT can reduce symptoms of post traumatic stress disorder (PTSD. This study examined the efficacy of an internet-delivered treatment protocol that combined iCBT and internet-delivered eye movement desensitization and reprocessing (iEMDR, in an uncontrolled trial. Eleven of the 15 participants completed post-treatment questionnaires. Large effect sizes were found from pre-treatment to 3-month follow-up (d = 1.03 – 1.61 on clinician-assessed and self-reported measures of PTSD, anxiety and distress, with moderate effect sizes (d = 0.59 – 0.70 found on measures of depression and disability. At post-treatment, 55% of the participants no longer met criteria for PTSD and this was sustained at follow-up. Symptom worsening occurred in 3 of 15 (20% of the sample from pre- to post-treatment; however, these participants reported overall symptom improvement by follow-up. Future research directions for iEMDR are discussed.

  4. Internet-delivered eye movement desensitization and reprocessing (iEMDR: an open trial [v1; ref status: indexed, http://f1000r.es/8l

    Directory of Open Access Journals (Sweden)

    Jay Spence

    2013-03-01

    Full Text Available Recent research indicates internet-delivered cognitive behavioural therapy (iCBT can reduce symptoms of post traumatic stress disorder (PTSD. This study examined the efficacy of an internet-delivered treatment protocol that combined iCBT and internet-delivered eye movement desensitization and reprocessing (iEMDR, in an uncontrolled trial. Eleven of the 15 participants completed post-treatment questionnaires. Large effect sizes were found from pre-treatment to 3-month follow-up (d = 1.03 – 1.61 on clinician-assessed and self-reported measures of PTSD, anxiety and distress, with moderate effect sizes (d = 0.59 – 0.70 found on measures of depression and disability. At post-treatment, 55% of the participants no longer met criteria for PTSD and this was sustained at follow-up. Symptom worsening occurred in 3 of 15 (20% of the sample from pre- to post-treatment; however, these participants reported overall symptom improvement by follow-up. Future research directions for iEMDR are discussed.

  5. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Cour, Morten la

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling...

  6. Research topics on EO systems for maritime platforms

    NARCIS (Netherlands)

    Dijk, J.; Bijl, P.; Broek, S.P. van den; Eijk, A.M.J. van

    2014-01-01

    Our world is constantly changing, and this has its effect on worldwide military operations. For example, there is a change from conventional warfare into a domain that contains asymmetric threats as well. The availability of high-quality imaging information from Electro-Optical (EO) sensors is of

  7. EOS Aqua: Mission Status at Earth Science Constellation

    Science.gov (United States)

    Guit, Bill

    2016-01-01

    This is an EOS Aqua Mission Status presentation to be given at the MOWG meeting in Albuquerque NM. The topics to discus are: mission summary, spacecraft subsystems summary, recent and planned activities, inclination adjust maneuvers, propellant usage and lifetime estimate, and mission summary.

  8. EoW criteria for waste-derived aggregates

    NARCIS (Netherlands)

    Hjelmar, O.; Sloot, van der H.A.; Comans, R.N.J.; Wahlstrom, H.

    2013-01-01

    Waste-derived aggregates are being considered as possible candidates for development of End-of-Waste (EoW) criteria at European Union (EU) level in accordance with Article 6 (1) of the EU Waste Framework Directive (2008/98/EC) as a means of increasing the recovery of resources from waste. If a

  9. Three phase carbon EOS model with electronic excitation

    International Nuclear Information System (INIS)

    van Thiel, M.; Ree, F.H.; Grover, R.

    1987-07-01

    A simple and rapid way for computing EOS data of multiphase solids with a liquid phase is described with emphasis on carbon. The method uses a scaling model for the liquid phase and includes a provision for electronic effects. The free energy minimum determines the stable phase

  10. 76 FR 31892 - Retrospective Review Under E.O. 13563

    Science.gov (United States)

    2011-06-02

    ..., Social Security Online, at http://www.socialsecurity.gov . SUPPLEMENTARY INFORMATION: On January 18, 2011... SOCIAL SECURITY ADMINISTRATION 20 CFR Chapter III [Docket No. SSA-2011-0042] Retrospective Review Under E.O. 13563 AGENCY: Social Security Administration. ACTION: Request for information. SUMMARY: In...

  11. EOS Operations Systems: EDOS Implemented Changes to Reduce Operations Costs

    Science.gov (United States)

    Cordier, Guy R.; Gomez-Rosa, Carlos; McLemore, Bruce D.

    2007-01-01

    The authors describe in this paper the progress achieved to-date with the reengineering of the Earth Observing System (EOS) Data and Operations System (EDOS), the experience gained in the process and the ensuing reduction of ground systems operations costs. The reengineering effort included a major methodology change, applying to an existing schedule driven system, a data-driven system approach.

  12. Fusion of Radar and EO-sensors for Surveillance

    NARCIS (Netherlands)

    Kester, L.J.H.M.; Theil, A.

    2001-01-01

    Fusion of radar and EO-sensors is investigated for the purpose of surveillance in littoral waters is. All sensors are considered to be co-located with respect to the distance, typically 1 to 10 km, of the area under surveillance. The sensor suite is a coherent polarimetric radar in combination with

  13. Different schematic eyes and their accuracy to the in vivo eye: a quantitative comparison study

    OpenAIRE

    Almeida, Marina Storani de; Carvalho, Luis Alberto

    2007-01-01

    Current ophthalmic technology allows the manipulation of eye components, such as anterior cornea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulat...

  14. Recent disruption of an asteroid from the Eos family

    Science.gov (United States)

    Novaković, B.; Tsirvoulis, G.

    2014-07-01

    A key difficulty with searching for partially differentiated asteroids arises from the fact that a crust covers the exterior of the body, and, consequently, should hide the melted interior. This motivates an alternative approach of examining members of asteroid families, i.e., fragments of single large bodies, many of which were in the size regime capable of igneous differentiation, that have been disrupted by catastrophic collisions. Such families could provide a stratigraphic cross section across the interior of the parent asteroid [1]. With more than 10,000 known members, the Eos dynamical family is one of the most numerous and earliest recognized asteroid families [2]. Interestingly, the estimated ˜220-km-diameter parent body [3] is well within the size range capable of differentiation. Thus, existing family members should contain fragments of the deep interior. The Eos family has the highest diversity of taxonomic classes than any other known family [4]. Many members are of K spectral type, which is uncommon outside the family, and is similar to the spectra of CV, CK, CO, and CR carbonaceous chondrites [5]. This diversity leads to the suggestion that the Eos parent body was partially differentiated [4,6]. Thus, the Eos family may not only be a remnant of a partially differentiated parent body, but it could be the source of the CV-CK meteorite group. Here we report the discovery of a young subfamily of the Eos asteroid family. It may help understanding the mineralogical nature of the Eos asteroid family and of its parent body. By applying the hierarchical clustering method [7], we find an extremely compact 16-body cluster within the borders of the Eos family. We name the cluster (6733) 1992 EF, after its largest member. The statistical significance of this new cluster is estimated to be above 99%, indicating that its members share a common origin. All members of the cluster are found to be dynamically stable over long timescales. Backward numerical orbital

  15. Eosinophilic Esophagitis in Children and Adolescents with Abdominal Pain: Comparison with EoE-Dysphagia and Functional Abdominal Pain.

    Science.gov (United States)

    Gunasekaran, Thirumazhisai; Prabhakar, Gautham; Schwartz, Alan; Gorla, Kiranmai; Gupta, Sandeep; Berman, James

    2016-01-01

    Aim. Compare EoE-AP with EoE-D for clinical, endoscopy (EGD), histology and outcomes and also with FAP-N. Method. Symptoms, physical findings, EGD, histology, symptom scores, and treatments were recorded for the three groups. Cluster analysis was done. Results. Dysphagia and abdominal pain were different in numbers but not statistically significant between EoE-AP and EoE-D. EGD, linear furrows, white exudates were more in the EoE-D and both combined were significant (p < 0.05). EoE-D, peak and mean eosinophils (p  0.06) and eosinophilic micro abscesses (p  0.001) were higher. Follow-Up. Based on single symptom, EoE-AP had 30% (p  0.25) improvement, EoE-D 86% (p < 0.001) and similar with composite score (p  0.57 and <0.001, resp.). Patients who had follow-up, EGD: 42.8% with EoE-AP and 77.8% with EoE-D, showed single symptom improvement and the eosinophil count fell from 38.5/34.6 (peak and mean) to 31.2/30.4 (p  0.70) and from 43.6/40.8 to 25.2/22.8 (p < 0.001), respectively. FAP-N patients had similar symptom improvement like EoE-D. Cluster Analysis. EoE-AP and FAP-N were similar in clinical features and response to treatment, but EoE-D was distinctly different from EoE-AP and FAP-N. Conclusion. Our study demonstrates that EoE-AP and EoE-D have different histology and outcomes. In addition, EoE-AP has clinical features similar to the FAP-N group.

  16. Pattern of Conjunctival Masses Seen At Guinness Eye Centre Luth ...

    African Journals Online (AJOL)

    Pattern of Conjunctival Masses Seen At Guinness Eye Centre Luth Idi-Araba. ... Open Access DOWNLOAD FULL TEXT Subscription or Fee ... 13.2% of eyes. Our study however did not confirm outdoor occupations as a risk factor for pterygium.

  17. A VidEo-Based Intelligent Recognition and Decision System for the Phacoemulsification Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Shu Tian

    2015-01-01

    Full Text Available The phacoemulsification surgery is one of the most advanced surgeries to treat cataract. However, the conventional surgeries are always with low automatic level of operation and over reliance on the ability of surgeons. Alternatively, one imaginative scene is to use video processing and pattern recognition technologies to automatically detect the cataract grade and intelligently control the release of the ultrasonic energy while operating. Unlike cataract grading in the diagnosis system with static images, complicated background, unexpected noise, and varied information are always introduced in dynamic videos of the surgery. Here we develop a VidEo-Based Intelligent Recognitionand Decision (VEBIRD system, which breaks new ground by providing a generic framework for automatically tracking the operation process and classifying the cataract grade in microscope videos of the phacoemulsification cataract surgery. VEBIRD comprises a robust eye (iris detector with randomized Hough transform to precisely locate the eye in the noise background, an effective probe tracker with Tracking-Learning-Detection to thereafter track the operation probe in the dynamic process, and an intelligent decider with discriminative learning to finally recognize the cataract grade in the complicated video. Experiments with a variety of real microscope videos of phacoemulsification verify VEBIRD’s effectiveness.

  18. Eye emergencies

    Science.gov (United States)

    ... eye can be caused by a work-related accident. It can also be caused by common household ... hammers, or other striking tools Working with toxic chemicals Cycling or when in windy and ... A.D.A.M.'s editorial policy , editorial process and privacy policy . A.D.A.M. is ...

  19. Eye Cancer

    Science.gov (United States)

    ... layer of tissue underneath the retina that contains connective tissue and melanocytes, which are pigmented (colored) cells, and nourishes the inside of the eye. The choroid is the most common site for a tumor. Types of intraocular cancer The most common intraocular cancer in adults is ...

  20. Eye trauma

    African Journals Online (AJOL)

    2011-02-02

    Feb 2, 2011 ... Note your findings in an orderly fashion: orbit, lids, conjunctiva, cornea, anterior chamber, iris, pupil reaction, lens, fundus. • Stain cornea with fluorescein. It is advisable to examine the eye as soon as possible since a delay will invariably lead to lid swelling, making the examination far more difficult. This can ...

  1. EOS: A project to investigate the design and construction of real-time distributed Embedded Operating Systems

    Science.gov (United States)

    Campbell, R. H.; Essick, Ray B.; Johnston, Gary; Kenny, Kevin; Russo, Vince

    1987-01-01

    Project EOS is studying the problems of building adaptable real-time embedded operating systems for the scientific missions of NASA. Choices (A Class Hierarchical Open Interface for Custom Embedded Systems) is an operating system designed and built by Project EOS to address the following specific issues: the software architecture for adaptable embedded parallel operating systems, the achievement of high-performance and real-time operation, the simplification of interprocess communications, the isolation of operating system mechanisms from one another, and the separation of mechanisms from policy decisions. Choices is written in C++ and runs on a ten processor Encore Multimax. The system is intended for use in constructing specialized computer applications and research on advanced operating system features including fault tolerance and parallelism.

  2. Western Eos Chaos on Mars: A Potential Site for Future Landing and Returning Samples

    Science.gov (United States)

    Asif Iqbal Kakkassery; Rajesh, V. J.

    2018-04-01

    Introducing Eos Chaos as a potential area for collecting samples. Eos Chaos contains a number of aqueous minerals. We have detected zoisite — a least reported low-grade metamorphic mineral from this area.

  3. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  4. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  5. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  6. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  7. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  8. MIRANDA: The EO-sensor Performance Tool Powered by EOSTAR-PRO - poster (Abstract)

    NARCIS (Netherlands)

    Hammel, S.H.; Tsintikidis, D.; Adonidis, M.; Degache, M.A.C.; Lange, D.J.J. de; Eijk, A.M.J. van

    2007-01-01

    Over the last decades, considerable efforts have been made to assess the impact of theenvironment on EM and EO propagation. While encouraging progress has been made in the EM domain, few, if any, operational tools are available for the EO domain. As a consequence, no EO operational software,

  9. 77 FR 3211 - USACE's Plan for Retrospective Review Under E.O. 13563

    Science.gov (United States)

    2012-01-23

    ... for Retrospective Review Under E.O. 13563 AGENCY: U.S. Army Corps of Engineers, DoD. ACTION: Extension..., ``Improving Regulation and Regulatory Review'' (E.O.), issued on January 18, 2011, directs federal agencies to... Regulatory mission; thus, USACE believes they are a significant rule warranting review pursuant to E.O. 13563...

  10. The EOS and neutrino interactions in dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, M; Reddy, S [Dept. of Physics and Astronomy, SUNY at Stony Brook, Stony Brook, NY (United States)

    1998-06-01

    The deleptonization and cooling times of a newly born neutron star depend on the equation of state (EOS) and neutrino opacities in dense matter. Through model calculations we show that effects of Pauli blocking and many-body correlations due to strong interactions reduce both the neutral and charged current neutrino cross sections by large factors compared to the case in which these effects are ignored. (orig.)

  11. Tactical EO/IE System for Ground Forces

    Science.gov (United States)

    1990-09-01

    this thesis is based on these ideas. We will give the guidelines to a project manager or to a beginner in EW research about EO/IR system acquisition...1982 Syria vs Israel Syria: 1 Syria 5+ By Syria: 89 by 96+ Sparrow AIM-9G/L PYTHON Korea: 1 B- Kamchatka 1983 Korea vs USSR 0 0 747(KAL-(07) by AA-3 or

  12. Studies on EOS of shock-generated argon plasmas

    International Nuclear Information System (INIS)

    Wang Fanhou; Jing Fuqian

    2001-01-01

    The equation of state for argon plasma, covering the thermodynamic states of 10000-30000 K in temperature and 0.0133-0.166 GPa in pressure, is computed using the Saha model and Debye-Huckel correction. Comparisons of the measured EOS with the calculated ones demonstrate the Saha model and Debye-Huckel correction can be used to well describe the essential behavior of argon plasma under the thermodynamic condition above-mentioned

  13. Spin states of asteroids in the Eos collisional family

    Science.gov (United States)

    Hanuš, J.; Delbo', M.; Alí-Lagoa, V.; Bolin, B.; Jedicke, R.; Ďurech, J.; Cibulková, H.; Pravec, P.; Kušnirák, P.; Behrend, R.; Marchis, F.; Antonini, P.; Arnold, L.; Audejean, M.; Bachschmidt, M.; Bernasconi, L.; Brunetto, L.; Casulli, S.; Dymock, R.; Esseiva, N.; Esteban, M.; Gerteis, O.; de Groot, H.; Gully, H.; Hamanowa, Hiroko; Hamanowa, Hiromi; Krafft, P.; Lehký, M.; Manzini, F.; Michelet, J.; Morelle, E.; Oey, J.; Pilcher, F.; Reignier, F.; Roy, R.; Salom, P. A.; Warner, B. D.

    2018-01-01

    Eos family was created during a catastrophic impact about 1.3 Gyr ago. Rotation states of individual family members contain information about the history of the whole population. We aim to increase the number of asteroid shape models and rotation states within the Eos collision family, as well as to revise previously published shape models from the literature. Such results can be used to constrain theoretical collisional and evolution models of the family, or to estimate other physical parameters by a thermophysical modeling of the thermal infrared data. We use all available disk-integrated optical data (i.e., classical dense-in-time photometry obtained from public databases and through a large collaboration network as well as sparse-in-time individual measurements from a few sky surveys) as input for the convex inversion method, and derive 3D shape models of asteroids together with their rotation periods and orientations of rotation axes. We present updated shape models for 15 asteroids and new shape model determinations for 16 asteroids. Together with the already published models from the publicly available DAMIT database, we compiled a sample of 56 Eos family members with known shape models that we used in our analysis of physical properties within the family. Rotation states of asteroids smaller than ∼ 20 km are heavily influenced by the YORP effect, whilst the large objects more or less retained their rotation state properties since the family creation. Moreover, we also present a shape model and bulk density of asteroid (423) Diotima, an interloper in the Eos family, based on the disk-resolved data obtained by the Near InfraRed Camera (Nirc2) mounted on the W.M. Keck II telescope.

  14. Management approach recommendations. Earth Observatory Satellite system definition study (EOS)

    Science.gov (United States)

    1974-01-01

    Management analyses and tradeoffs were performed to determine the most cost effective management approach for the Earth Observatory Satellite (EOS) Phase C/D. The basic objectives of the management approach are identified. Some of the subjects considered are as follows: (1) contract startup phase, (2) project management control system, (3) configuration management, (4) quality control and reliability engineering requirements, and (5) the parts procurement program.

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  17. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  18. The use of EOS for studies of atmospheric physics

    Energy Technology Data Exchange (ETDEWEB)

    Gille, J G; Visconti, G [eds.

    1992-01-01

    Attention is paid to the atmosphere and how the understanding of its behavior could be facilitated by the observations and modeling of these interacting processes planned within the framework of the EOS (Earth Observing System) program. The Enrico Fermi School on which the book is based, was organized in such a way that general introductory lectures were followed by reviews of the planned EOS instruments and observational strategy to study specific components and processes in the earth atmosphere system. The contents are divided into four parts. Part 1 is an overview of the EOS concept and provides a general introduction to earth system science. Part 2 deals with the troposphere and includes a comprehensive introduction to the problems of tropospheric chemistry. The more traditional view of the troposphere as the stage for dynamics and meteorology is also dealt with. The climate system is discussed in detail in part 3, and includes the most important advances made in recent years in understanding some of these processes which have come from satellite observations. The final part deals with the middle atmosphere. The interest in ozone has made this region of the atmosphere the most closely studied in the last few years, in an attempt to establish how much of the changes in its composition may be attributable to natural variability and how much to anthropogenic influence

  19. Vapor-liquid, liquid-liquid and vapor-liquid-liquid equilibrium of binary and multicomponent systems with MEG modeling with the CPA EoS and an EoS/G(E) model

    DEFF Research Database (Denmark)

    Folas, Georgios; Kontogeorgis, Georgios; Michelsen, Michael Locht

    2006-01-01

    The cubic-plus-association (CPA) EoS is applied to multicomponent multiphase equilibria of systems containing MEG as a hydrate inhibitor. It is shown that the model provides very satisfactory prediction of the phase behavior for the systems tested. A more conventional engineering model for handling...

  20. SenSyF Experience on Integration of EO Services in a Generic, Cloud-Based EO Exploitation Platform

    Science.gov (United States)

    Almeida, Nuno; Catarino, Nuno; Gutierrez, Antonio; Grosso, Nuno; Andrade, Joao; Caumont, Herve; Goncalves, Pedro; Villa, Guillermo; Mangin, Antoine; Serra, Romain; Johnsen, Harald; Grydeland, Tom; Emsley, Stephen; Jauch, Eduardo; Moreno, Jose; Ruiz, Antonio

    2016-08-01

    SenSyF is a cloud-based data processing framework for EO- based services. It has been pioneer in addressing Big Data issues from the Earth Observation point of view, and is a precursor of several of the technologies and methodologies that will be deployed in ESA's Thematic Exploitation Platforms and other related systems.The SenSyF system focuses on developing fully automated data management, together with access to a processing and exploitation framework, including Earth Observation specific tools. SenSyF is both a development and validation platform for data intensive applications using Earth Observation data. With SenSyF, scientific, institutional or commercial institutions developing EO- based applications and services can take advantage of distributed computational and storage resources, tailored for applications dependent on big Earth Observation data, and without resorting to deep infrastructure and technological investments.This paper describes the integration process and the experience gathered from different EO Service providers during the project.

  1. Eye Contricks

    Directory of Open Access Journals (Sweden)

    N Wade

    2011-04-01

    Full Text Available Icons are eye-cons: they provide a distillation of a complex object or idea into a simple pictorial shape. They create the impression of representing that which cannot be presented. Even at the level of the photograph, the links between icon and object are tenuous. The dimension of distance or depth is missing from the icon, and this alone introduces all manner of potential ambiguities. The history of art can be considered as an exploration of the missing link between icon and object. Eye-cons are more honest—they are tricks of vision so that what is seen does not necessarily correspond to what is presented. They are visual allusions rather than visual illusions, although they can display illusory effects. At its broadest, icon can be equated with image. The concept of image has thrived on its vagueness, and so attempts have been made to refine it. An icon corresponds to an optical image: it shares some of the projective characteristics of the object represented. Written words are also icons but they do not resemble the objects they represent—they are stylised or conventional rather than spatialised and projective. Words and images were set in delightful opposition by René Magritte (1898-1967 in a series of pipe paintings, and he also played on the theme of the arbitrariness of the verbal labels assigned to objects. What is surprising is that Magritte did not apply his painterly skills to transforming the word shapes he used. A similar reluctance to transform the typefaces pervades visual poetry. My interests are in the visual rather than the poetic dimension, and I will present a range of my own eye contricks which play with letter and word shapes in a variety of ways.

  2. Comprehensive eye evaluation algorithm

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.

    2016-03-01

    In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.

  3. Comparison of GERG-2008 and simpler EoS models in calculation of phase equilibrium and physical properties of natural gas related systems

    DEFF Research Database (Denmark)

    Varzandeh, Farhad; Stenby, Erling Halfdan; Yan, Wei

    2017-01-01

    Accurate description of thermodynamic properties of natural gas systems is of great significance in the oil and gas industry. For this application, non-cubic equations of state (EoSs) are advantageous due to their better density and compressibility description. Among the non-cubic models, GERG-2008...... is a new wide-range EoS for natural gases and other mixtures of 21 natural gas components. It is considered as a standard reference equation suitable for natural gas applications where highly accurate thermodynamic properties are required. Soave's modification of Benedict-Webb-Rubin (Soave-BWR) Eo......S is another model that despite its empirical nature, provides accurate density description even around the critical point. It is much simpler than GERG-2008 and easier to handle and generalize to reservoir oil fluids. This study presents a comprehensive comparison between GERG-2008 and other cubic (SRK and PR...

  4. EOS MLS Level 1B Data Processing Software. Version 3

    Science.gov (United States)

    Perun, Vincent S.; Jarnot, Robert F.; Wagner, Paul A.; Cofield, Richard E., IV; Nguyen, Honghanh T.; Vuu, Christina

    2011-01-01

    This software is an improvement on Version 2, which was described in EOS MLS Level 1B Data Processing, Version 2.2, NASA Tech Briefs, Vol. 33, No. 5 (May 2009), p. 34. It accepts the EOS MLS Level 0 science/engineering data, and the EOS Aura spacecraft ephemeris/attitude data, and produces calibrated instrument radiances and associated engineering and diagnostic data. This version makes the code more robust, improves calibration, provides more diagnostics outputs, defines the Galactic core more finely, and fixes the equator crossing. The Level 1 processing software manages several different tasks. It qualifies each data quantity using instrument configuration and checksum data, as well as data transmission quality flags. Statistical tests are applied for data quality and reasonableness. The instrument engineering data (e.g., voltages, currents, temperatures, and encoder angles) is calibrated by the software, and the filter channel space reference measurements are interpolated onto the times of each limb measurement with the interpolates being differenced from the measurements. Filter channel calibration target measurements are interpolated onto the times of each limb measurement, and are used to compute radiometric gain. The total signal power is determined and analyzed by each digital autocorrelator spectrometer (DACS) during each data integration. The software converts each DACS data integration from an autocorrelation measurement in the time domain into a spectral measurement in the frequency domain, and estimates separately the spectrally, smoothly varying and spectrally averaged components of the limb port signal arising from antenna emission and scattering effects. Limb radiances are also calibrated.

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  7. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  8. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  9. The International Ethics Conference: An Eye Opener

    Science.gov (United States)

    Phuma, Ellemes

    2010-01-01

    In this text, Ellemes Phuma, shares her experience and the benefits she derived from the International Ethics Conference held at the University of Botswana (UB). As a graduate student in nursing at that university, she provides her perspective on professional responsibility, compassionate healthcare, and the ethical role that healthcare…

  10. Heterogeneous access and processing of EO-Data on a Cloud based Infrastructure delivering operational Products

    Science.gov (United States)

    Niggemann, F.; Appel, F.; Bach, H.; de la Mar, J.; Schirpke, B.; Dutting, K.; Rucker, G.; Leimbach, D.

    2015-04-01

    To address the challenges of effective data handling faced by Small and Medium Sized Enterprises (SMEs) a cloud-based infrastructure for accessing and processing of Earth Observation(EO)-data has been developed within the project APPS4GMES(www.apps4gmes.de). To gain homogenous multi mission data access an Input Data Portal (IDP) been implemented on this infrastructure. The IDP consists of an Open Geospatial Consortium (OGC) conformant catalogue, a consolidation module for format conversion and an OGC-conformant ordering framework. Metadata of various EO-sources and with different standards is harvested and transferred to an OGC conformant Earth Observation Product standard and inserted into the catalogue by a Metadata Harvester. The IDP can be accessed for search and ordering of the harvested datasets by the services implemented on the cloud infrastructure. Different land-surface services have been realised by the project partners, using the implemented IDP and cloud infrastructure. Results of these are customer ready products, as well as pre-products (e.g. atmospheric corrected EO data), serving as a basis for other services. Within the IDP an automated access to ESA's Sentinel-1 Scientific Data Hub has been implemented. Searching and downloading of the SAR data can be performed in an automated way. With the implementation of the Sentinel-1 Toolbox and own software, for processing of the datasets for further use, for example for Vista's snow monitoring, delivering input for the flood forecast services, can also be performed in an automated way. For performance tests of the cloud environment a sophisticated model based atmospheric correction and pre-classification service has been implemented. Tests conducted an automated synchronised processing of one entire Landsat 8 (LS-8) coverage for Germany and performance comparisons to standard desktop systems. Results of these tests, showing a performance improvement by the factor of six, proved the high flexibility and

  11. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  13. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On ... Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms Causes of ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Dry Eye Symptoms Related Ask an Ophthalmologist Answers Can a six-month dissolvable punctal plug be removed ... my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes ...

  17. Eye Injuries at Work

    Science.gov (United States)

    ... National Standards Institute (ANSI) to meet their eye protection standards. If an eye injury occurs, see an ophthalmologist or go to the emergency room immediately, even if the eye injury appears minor. Delaying medical attention can result in permanent vision ...

  18. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  19. Evaluation of a remote webcam-based eye tracker

    DEFF Research Database (Denmark)

    Skovsgaard, Henrik; Agustin, Javier San; Johansen, Sune Alstrup

    2011-01-01

    In this paper we assess the performance of an open-source gaze tracker in a remote (i.e. table-mounted) setup, and compare it with two other commercial eye trackers. An experiment with 5 subjects showed the open-source eye tracker to have a significantly higher level of accuracy than one...

  20. Mission operations update for the restructured Earth Observing System (EOS) mission

    Science.gov (United States)

    Kelly, Angelita Castro; Chang, Edward S.

    1993-01-01

    The National Aeronautics and Space Administration's (NASA) Earth Observing System (EOS) will provide a comprehensive long term set of observations of the Earth to the Earth science research community. The data will aid in determining global changes caused both naturally and through human interaction. Understanding man's impact on the global environment will allow sound policy decisions to be made to protect our future. EOS is a major component of the Mission to Planet Earth program, which is NASA's contribution to the U.S. Global Change Research Program. EOS consists of numerous instruments on multiple spacecraft and a distributed ground system. The EOS Data and Information System (EOSDIS) is the major ground system developed to support EOS. The EOSDIS will provide EOS spacecraft command and control, data processing, product generation, and data archival and distribution services for EOS spacecraft. Data from EOS instruments on other Earth science missions (e.g., Tropical Rainfall Measuring Mission (TRMM)) will also be processed, distributed, and archived in EOSDIS. The U.S. and various International Partners (IP) (e.g., the European Space Agency (ESA), the Ministry of International Trade and Industry (MITI) of Japan, and the Canadian Space Agency (CSA)) participate in and contribute to the international EOS program. The EOSDIS will also archive processed data from other designated NASA Earth science missions (e.g., UARS) that are under the broad umbrella of Mission to Planet Earth.

  1. A European Collaborative EO Summer School for the Education of Undergraduate and Masters Level Students- FORMAT-EO

    Science.gov (United States)

    Graves, Rosemarie; Remedios, John; Tramutoli, Valerio; Gil, Artur; Cuca, Branka

    2014-05-01

    An Erasmus intensive programme has been successfully funded to run a Europe-lead summer school in Earth Observation for the years 2013 and 2014. The summer school, FORMAT-EO (FORmation of Multi-disciplinary Approaches to Training in Earth Observation) has been proposed and implemented by a consortium of eight partner institutions from five European countries. The consortium was facilitated through the NEREUS network. In the summer of 2013, 21 students from seven European institutions took part in the two week intensive course which involved a total of 28 teachers from six institutions. Students were from a variety of backgrounds including aeronautical engineering MSc students and PhD students in the areas of marine biology, earthquake engineering and measurement of trace gases in the atmosphere. The aims of FORMAT-EO were: To give students exposure to the wider applications of Earth Observation To highlight the interdisciplinary, collaborative and international nature of Earth Observation To offer an intensive course to better equip students with specialist skills required for a career in this field To provide expert advice on the development of careers in the EO market Partners were invited not only to recruit students for the course but to also teach at the school based on their specific area of expertise. This approach to the teaching provided a timetable which was wide-ranging and covered topics from EU policies for Earth Observation to fire detection from space and an introduction to interaction between radiation and matter. An important aspect of the course was the interactive nature of much of the teaching. A topic was introduced to the students through a lecture followed by an interactive tutorial providing students with hands-on experience of working with EO data and specialist software. The final days of the summer school were spent on group project work which required students to use all of the skills that they acquired during the course to challenge a

  2. Pathological items - Open TG-GATEs | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available . Data file File name: open_tggates_pathology.zip File URL: ftp://ftp.biosciencedbc.jp/archive/open-tggates/LATEST/open_tggates_patho...b.biosciencedbc.jp/togodb/view/open_tggates_pathology#en Data acquisition method We prepared hematoxylin-eos...logy.zip File size: 89 KB Simple search URL http://togod

  3. Chapter 2. Eyes

    International Nuclear Information System (INIS)

    Blanquet, P.

    1975-01-01

    Ocular scintigraphy can now be carried out with several tracers: 131 I diiodofluorescein and sup(99m)Tc, hypervascularisation indicators; 131 I iodinated chloroquine, melanoma selective. The detector used is an Anger scintillation camera coupled to a multiparameter analysis chain or a computer. The ''pin-hole'' type collimator, which has a stenopaeic opening in front of each eye, is adaptable to any inter-pupil distance. The very simple scintigraphic procedure is described. The results, taken from two statistical studies on 198 and 80 patients respectively, concern the main types of eye disease encountered: malignant melanic tumours, other tumours, metastases, choroiditis, idiopathic detachments of the retina etc... The interpretation of the scintigrams and the problems involved are considered. Finally the main indications of the method are defined with emphasis on the possibilities of double scintigraphy, diiodofluorescein only showing up the hypervascularisation often associated with the tumour whereas iodinated chloroquine, when the result is positive, points to the presence of a malignant melanoma [fr

  4. The Chelyabinsk superbolide: a fragment of asteroid 2011 EO40?

    Science.gov (United States)

    de la Fuente Marcos, C.; de la Fuente Marcos, R.

    2013-11-01

    Bright fireballs or bolides are caused by meteoroids entering the Earth's atmosphere at high speed. Some have a cometary origin, a few may have originated within the Venus-Earth-Mars region as a result of massive impacts in the remote past but a relevant fraction is likely the result of the break-up of asteroids. Disrupted asteroids produce clusters of fragments or asteroid families and meteoroid streams. Linking a bolide to a certain asteroid family may help to understand its origin and pre-impact dynamical evolution. On 2013 February 15, a superbolide was observed in the skies near Chelyabinsk, Russia. Such a meteor could be the result of the decay of an asteroid and here we explore this possibility applying a multistep approach. First, we use available data and Monte Carlo optimization (validated using 2008 TC3 as template) to obtain a robust solution for the pre-impact orbit of the Chelyabinsk impactor (a = 1.62 au, e = 0.53, i = 3.82°, Ω = 326.41° and ω = 109.44°). Then, we use this most probable orbit and numerical analysis to single out candidates for membership in, what we call, the Chelyabinsk asteroid family. Finally, we perform N-body simulations to either confirm or reject any dynamical connection between candidates and impactor. We find reliable statistical evidence on the existence of the Chelyabinsk cluster. It appears to include multiple small asteroids and two relatively large members: 2007 BD7 and 2011 EO40. The most probable parent body for the Chelyabinsk superbolide is 2011 EO40. The orbits of these objects are quite perturbed as they experience close encounters not only with the Earth-Moon system but also with Venus, Mars and Ceres. Under such conditions, the cluster cannot be older than about 20-40 kyr.

  5. Structure and optics of the eyes of the box jellyfish Chiropsella bronzie

    DEFF Research Database (Denmark)

    O’Connor, Megan; Garm, Anders Lydik; Nilsson, Dan-E.

    2009-01-01

    Cubomedusae have a total of 24 eyes of four morphologically different types. Two of these eye types are camera-type eyes (upper and lower lens-eye), while the other two eye types are simpler pigment pit eyes (pit and slit eye). Here, we give a description of the visual system of the box jellyfish...... those in the previously investigated species Tripedalia cystophora. In the lower lens-eye of C. bronzie, blur circles subtend 20 and 52° for closed and open pupil, respectively, effectively removing all but the coarsest structures of the image. Histology reveals that the retina of the lower lens...

  6. Understanding (Galactic) Foreground Emission: A Road To Success For The LOFAR-EoR Experiment

    NARCIS (Netherlands)

    Jelic, Vibor; Lofar Eor Team, [Unknown

    The LOFAR-EoR experiment will use the innovative technology and capabilities of the radio telescope LOFAR to study the Epoch of Reionization (EoR). However, feeble cosmological radiation is swamped by the prominent foreground emission of our Galaxy and other extragalactic radio sources. This

  7. Promoting Strategic STEM Education Outreach Programming Using a Systems-Based STEM-EO Model

    Science.gov (United States)

    Ward, Annmarie R.

    2015-01-01

    In this paper a STEM Education Outreach (STEM-EO) Model for promoting strategic university outreach programming at Penn State University to the benefit of university, school district and community stakeholders is described. The model considers STEM-EO as a complex system involving overarching learning goals addressed within four outreach domains…

  8. 44 CFR Appendix A to Part 9 - Decision-making Process for E.O. 11988

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Decision-making Process for E.O. 11988 A Appendix A to Part 9 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT..., App. A Appendix A to Part 9—Decision-making Process for E.O. 11988 EC02FE91.074 ...

  9. EO Domain Specific Knowledge Enabled Services (KES-B)

    Science.gov (United States)

    Varas, J.; Busto, J.; Torguet, R.

    2004-09-01

    This paper recovers and describes a number of major statements with respect to the vision, mission and technological approaches of the Technological Research Project (TRP) "EO Domain Specific Knowledge Enabled Services" (project acronym KES-B), which is currently under development at the European Space Research Institute (ESRIN) under contract "16397/02/I- SB". Resulting from the on-going R&D activities, the KES-B project aims are to demonstrate with a prototype system the feasibility of the application of innovative knowledge-based technologies to provide services for easy, scheduled and controlled exploitation of EO resources (e.g.: data, algorithms, procedures, storage, processors, ...), to automate the generation of products, and to support users in easily identifying and accessing the required information or products by using their own vocabulary, domain knowledge and preferences. The ultimate goals of KES-B are summarized in the provision of the two main types of KES services: 1st the Search service (also referred to as Product Exploitation or Information Retrieval; and 2nd the Production service (also referred to as Information Extraction), with the strategic advantage that they are enabled by Knowledge consolidated (formalized) within the system. The KES-B system technical solution approach is driven by a strong commitment for the adoption of industry (XML-based) language standards, aiming to have an interoperable, scalable and flexible operational prototype. In that sense, the Search KES services builds on the basis of the adoption of consolidated and/or emergent W3C semantic-web standards. Remarkably the languages/models Dublin Core (DC), Universal Resource Identifier (URI), Resource Description Framework (RDF) and Ontology Web Language (OWL), and COTS like Protege [1] and JENA [2] are being integrated in the system as building bricks for the construction of the KES based Search services. On the other hand, the Production KES services builds on top of

  10. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  11. Steps Toward an EOS-Era Aerosol Type Climatology

    Science.gov (United States)

    Kahn, Ralph A.

    2012-01-01

    We still have a way to go to develop a global climatology of aerosol type from the EOS-era satellite data record that currently spans more than 12 years of observations. We have demonstrated the ability to retrieve aerosol type regionally, providing a classification based on the combined constraints on particle size, shape, and single-scattering albedo (SSA) from the MISR instrument. Under good but not necessarily ideal conditions, the MISR data can distinguish three-to-five size bins, two-to-four bins in SSA, and spherical vs. non-spherical particles. However, retrieval sensitivity varies enormously with scene conditions. So, for example, there is less information about aerosol type when the mid-visible aerosol optical depth (AOD) is less that about 0.15 or 0.2, or when the range of scattering angles observed is reduced by solar geometry, even though the quality of the AOD retrieval itself is much less sensitive to these factors. This presentation will review a series of studies aimed at assessing the capabilities, as well as the limitations, of MISR aerosol type retrievals involving wildfire smoke, desert dust, volcanic ash, and urban pollution, in specific cases where suborbital validation data are available. A synthesis of results, planned upgrades to the MISR Standard aerosol algorithm to improve aerosol type retrievals, and steps toward the development of an aerosol type quality flag for the Standard product, will also be covered.

  12. EOS MLS Level 2 Data Processing Software Version 3

    Science.gov (United States)

    Livesey, Nathaniel J.; VanSnyder, Livesey W.; Read, William G.; Schwartz, Michael J.; Lambert, Alyn; Santee, Michelle L.; Nguyen, Honghanh T.; Froidevaux, Lucien; wang, Shuhui; Manney, Gloria L.; hide

    2011-01-01

    This software accepts the EOS MLS calibrated measurements of microwave radiances products and operational meteorological data, and produces a set of estimates of atmospheric temperature and composition. This version has been designed to be as flexible as possible. The software is controlled by a Level 2 Configuration File that controls all aspects of the software: defining the contents of state and measurement vectors, defining the configurations of the various forward models available, reading appropriate a priori spectroscopic and calibration data, performing retrievals, post-processing results, computing diagnostics, and outputting results in appropriate files. In production mode, the software operates in a parallel form, with one instance of the program acting as a master, coordinating the work of multiple slave instances on a cluster of computers, each computing the results for individual chunks of data. In addition, to do conventional retrieval calculations and producing geophysical products, the Level 2 Configuration File can instruct the software to produce files of simulated radiances based on a state vector formed from a set of geophysical product files taken as input. Combining both the retrieval and simulation tasks in a single piece of software makes it far easier to ensure that identical forward model algorithms and parameters are used in both tasks. This also dramatically reduces the complexity of the code maintenance effort.

  13. La edad de las familias Eos, Themis y Koronis

    Science.gov (United States)

    Gil-Hutton, R.

    Las familias de asteroides son el producto de la disrupción colisional de objetos destruídos por impactos ocurridos en el cinturón principal. Las colisiones posteriores han modificado los tamaños y las órbitas de los miembros de estas familias, por lo que las distribuciones que vemos hoy en día pueden ser muy diferentes de aquellas producidas inmediatamente después de la fragmentación del objeto original. En esta hipótesis, puede ser difícil reconstruir la evolución colisional de la familia basándose sólo en las actuales distribuciones y puede ser necesario hacer ciertas suposiciones para obtener información sobre las condiciones iniciales. En este trabajo se deriva una estimación de la edad de las familias Eos, Themis y Koronis obtenida de una simulación de la evolución colisional de un cuerpo original teórico para cada familia usando un modelo de distribución para el cinturón propuesto por Gil-Hutton (1996).

  14. Mechanism of growth retardation of the adenocarcinoma EO 771

    International Nuclear Information System (INIS)

    Bassukas, I.D.; Maurer-Schultze, B.

    1987-01-01

    Growth retardation of tumors has been predominantly described by an increase of the ''cell loss factor'' Φ. However, this cell loss factor alone merely reflects the growth deceleration without giving information on the mechanism that causes growth retardation. In the present study a quantitative analysis of the mechanism causing growth retardation of the adenocarcinoma EO 771 has been carried out by determining separately the components of the cell loss factor Φ, namely the cell production rate and the cell loss rate of the tumor cell population. For this purpose the alteration of the histology of the tumor (proportion of necrotic tumor tissue, tumor cell density) and the proliferative capacity of the tumor cell population as a function of the tumor size was studied by applying morphometric and cell kinetic methods. The results show that growth deceleration is due to a decrease of the cell production rate k p and a simultaneous increase of the cell rate k l . Both processes contribute to about the same extent to the growth deceleration of the tumor cell population. In early tumor growth deceleration is mainly due to a prolongation of the cycle time of the tumor cells, in later phases of tumor growth to an increasing probability of the tumor cells to decycle leading to a decrease of the growth fraction GF and an increase of the cell loss rate k l . (orig.)

  15. Addressing EO-1 Spacecraft Pulsed Plasma Thruster EMI Concerns

    Science.gov (United States)

    Zakrzwski, C. M.; Davis, Mitch; Sarmiento, Charles; Bauer, Frank H. (Technical Monitor)

    2001-01-01

    The Pulsed Plasma Thruster (PPT) Experiment on the Earth Observing One (EO-1) spacecraft has been designed to demonstrate the capability of a new generation PPT to perform spacecraft attitude control. Results from PPT unit level radiated electromagnetic interference (EMI) tests led to concerns about potential interference problems with other spacecraft subsystems. Initial plans to address these concerns included firing the PPT at the spacecraft level both in atmosphere, with special ground support equipment. and in vacuum. During the spacecraft level tests, additional concerns where raised about potential harm to the Advanced Land Imager (ALI). The inadequacy of standard radiated emission test protocol to address pulsed electromagnetic discharges and the lack of resources required to perform compatibility tests between the PPT and an ALI test unit led to changes in the spacecraft level validation plan. An EMI shield box for the PPT was constructed and validated for spacecraft level ambient testing. Spacecraft level vacuum tests of the PPT were deleted. Implementation of the shield box allowed for successful spacecraft level testing of the PPT while eliminating any risk to the ALI. The ALI demonstration will precede the PPT demonstration to eliminate any possible risk of damage of ALI from PPT operation.

  16. [Firework-related eye trauma from 2005 to 2013].

    Science.gov (United States)

    Unterlauft, J D; Wiedemann, P; Meier, P

    2014-09-01

    Fireworks combusted during New Year's Eve festivities can cause different eye traumas which often need complex reconstructive surgery. It was our aim to systematically analyse these eye trauma cases which were treated at our clinic during the last eight years. Age, gender, side, trauma mechanism, treatment methods and outcome were analysed for all eye trauma cases caused by fireworks during the New Year's Eve celebrations from 2006 to 2013. For statistical analysis all trauma cases were divided into two groups of major and non-major eye trauma. The total number of patients treated was 122 (28 women, 94 men, mean age 26.2±13.0 years) with 137 traumatised eyes (77 right, 60 left). 24.6% of patients were ≤18 years of age. 76.2% were bystanders. 50 eyes from 46 patients (37.7%) suffered from major eye trauma. 26 patients (21.3%) were hospitalised. 8 eyes (5.8%) suffered from a penetrating injury or globe rupture and underwent primary reconstructive surgery. Further 16 eyes (11.7%) suffered from major eye trauma without open globe injury. In the aftermath 11 eyes (8.0%) went blind (visual acuityfireworks. However older patients suffer from major eye trauma more often. More education and prophylaxis of eye trauma caused by fireworks is desirable. Georg Thieme Verlag KG Stuttgart · New York.

  17. Activity coefficients at infinite dilution of hydrocarbons in glycols: Experimental data and thermodynamic modeling with the GCA-EoS

    International Nuclear Information System (INIS)

    González Prieto, Mariana; Williams-Wynn, Mark D.; Bahadur, Indra; Sánchez, Francisco A.; Mohammadi, Amir H.

    2017-01-01

    Highlights: • Experimental infinite dilution activity coefficients of hydrocarbons in glycols. • Inverse gas-liquid chromatography technique. • Solutes investigated include n-alkanes, 1-alkenes, and cycloalkanes. • Highly non-ideal systems are modeled with the GCA-EoS. - Abstract: The infinite dilution activity coefficients for 12 non-polar hydrocarbon solutes in the solvents, monoethylene and diethylene glycol, were measured using the gas-liquid chromatography technique. Pre-saturation of the carrier gas was required to avoid solvent loss from the chromatographic column during the measurements that were carried out at T = (303.15, 313.15 and 323.15) K for monoethylene glycol and at T = (304.15, 313.15 and 323.15) K for diethylene glycol. The solutes investigated include n-alkanes, 1-alkenes, and cycloalkanes. The new data are compared with the highly scattered data that is available in the open literature. Finally, these highly non-ideal systems are modeled with the GCA-EoS.

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Kierstan Boyd Reviewed By: Brenda Pagan-Duran MD Sep. 01, 2017 Our eyes need tears to stay ... tear duct to insert a permanent punctal plug? Sep 12, 2017 Why are my eyes bloodshot when ...

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... seasonal allergens and dry eye Apr 27, 2015 Choosing Wisely When It Comes to Eye Care, Part ... Name: Member ID: * Phone Number: * Email: * Enter code: * Message: Thank you Your feedback has been sent.

  20. About the Eye

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  1. Pink Eye (Conjunctivitis)

    Science.gov (United States)

    ... or child care if you're not able to take time off — just stay consistent in practicing good hygiene. Preventing pink eye in newborns Newborns' eyes are susceptible to bacteria normally present in the mother's birth canal. ...

  2. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... much as it does on your eyes. ... of Health | USA.gov NIH…Turning Discovery Into Health ®

  3. About the Eye

    Medline Plus

    Full Text Available ... Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  4. Preventing Eye Injuries

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  5. About the Eye

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and ...

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... right type of tears or tear film . How do tears work? When you blink, a film of ... layer cleans the eye, washing away particles that do not belong in the eye. This layer comes ...

  8. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid ... Your eyes are made up of many different parts that work together to help you see. Check out the ...

  9. About the Eye

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes ...

  10. About the Eye

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  11. About the Eye

    Medline Plus

    Full Text Available ... Home » NEI for Kids » About the Eye Listen All About Vision About the Eye Ask a Scientist ... you can see and make sense of the world around you. Did You Know? Vision depends on ...

  12. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  13. Eye Involvement in TSC

    Science.gov (United States)

    ... eye involvement. Nonretinal and Retinal Eye Findings Facial angiofibromas may involve the eyelids of individuals with TSC, ... the hamartomas have many blood vessels (as are angiofibromas of the skin). Less than half of the ...

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... removed or pushed down the tear duct to insert a permanent punctal plug? Sep 12, 2017 Why ... Eye from Jennifer Aniston Sep 02, 2016 The link between seasonal allergens and dry eye Apr 27, ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet ...

  16. About the Eye

    Medline Plus

    Full Text Available ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about ...

  17. About the Eye

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ...

  18. Immunology of the eye

    OpenAIRE

    Weronika Ratajczak; Beata Tokarz-Deptuła; Wiesław Deptuła

    2018-01-01

    The eye is an organ of sight characterized by unusual immunological properties, resulting from its anatomical structure and physiology, as well as the presence of specific elements that, through the mechanisms of innate and adaptive immunity, provide homeostasis of the eyeball. This article reviews the defensive elements of individual eye structures: conjunctiva, cornea, lacrimal gland, anterior chamber of the eye, uvea, retina and eye-associated lymphoid tissue (EALT), where we distinguish a...

  19. Molecular Solid EOS based on Quasi-Harmonic Oscillator approximation for phonons

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-09-02

    A complete equation of state (EOS) for a molecular solid is derived utilizing a Helmholtz free energy. Assuming that the solid is nonconducting, phonon excitations dominate the specific heat. Phonons are approximated as independent quasi-harmonic oscillators with vibrational frequencies depending on the specific volume. The model is suitable for calibrating an EOS based on isothermal compression data and infrared/Raman spectroscopy data from high pressure measurements utilizing a diamond anvil cell. In contrast to a Mie-Gruneisen EOS developed for an atomic solid, the specific heat and Gruneisen coefficient depend on both density and temperature.

  20. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists

  1. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  2. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  3. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  4. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  5. Recognizing and Treating Eye Injuries

    Science.gov (United States)

    ... Eye Injuries First Aid for Eye Scratches Protective Eyewear Children’s Eye Injuries: Prevention and Care Eye Injuries ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  6. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    Science.gov (United States)

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  7. Distribution of MEG and methanol in well-defined hydrocarbon and water systems: Experimental measurement and modeling using the CPA EoS

    DEFF Research Database (Denmark)

    Riaz, Muhammad; Yussuf, Mustafe A.; Kontogeorgis, Georgios

    2013-01-01

    + water. These data are satisfactorily correlated (binaries) and predicted (ternaries) using Cubic Plus Association (CPA) equation of state (EoS). CPA is also applied to binary LLE of aromatic hydrocarbon + water and VLE of methane + methanol. Finally the distribution of water and inhibitors (methanol...... and MEG) in various phases is modeled using CPA. The hydrocarbon phase consists of mixture-1 (methane, ethane, n-butane) or mixture-2 (methane, ethane, propane, n-butane, n-heptane, toluene and n-decane). CPA can satisfactorily predict the water content in the gas phase of the multicomponent systems...

  8. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  9. Electrostatic Discharge (ESD and Electrical Overstress (EOS: The state of the art in components to systems

    Directory of Open Access Journals (Sweden)

    Steven H. Voldman

    2017-06-01

    Full Text Available Electrostatic Discharge (ESD, Electrical Overstress (EOS and electromagnetic compatibility (EMC continue to impact semiconductor manufacturing, semiconductor components and systems as technologies scale from micro- to nano-electronics. The range of concern for components include semiconductor components, magnetic recording industry, MEMs, and for products from disk drives, cell phones, notebooks, tablets, laptops, and desktop computers. The objective of this lecture is to address the state of the art of electrostatic discharge (ESD and electrical overstress (EOS in today’s electronic components and systems. The tutorial provides a clear picture of ESD, EOS and EMC phenomena, sources, physics, failure mechanisms, testing and qualification of components and systems. The conclusion of this talk is that ESD and EOS continue to be a concern in technologies from micro-electronics to nano-structures, and will remain a reliability and quality issue in the future.

  10. EOS Aura Mission Status at Earth Science Constellation MOWG Meeting @ LASP (Boulder, CO) April 13, 2016

    Science.gov (United States)

    Guit, William J.; Fisher, Dominic

    2016-01-01

    Presentation reflects EOS Aura mission status, spacecraft subsystems summary, recent and planned activities, inclination adjust maneuvers, propellant usage, orbit maintenance maneuvers, conjunction assessment events, orbital parameters trends and predictions.

  11. EOS Aqua Mission Status at Earth Science Constellation MOWG Meeting @ LASP April 13, 2016

    Science.gov (United States)

    Guit, William J.

    2016-01-01

    This presentation reflects the EOS Aqua mission status, spacecraft subsystem summary, recent and planned activities, inclination adjust maneuvers, propellant usage and lifetime estimate, orbital maintenance maneuvers, conjunction assessment high interest events, ground track error, spacecraft orbital parameters trends and predictions.

  12. System testing software deployments using Docker and Kubernetes in gitlab CI: EOS + CTA use case

    CERN Document Server

    CERN. Geneva

    2017-01-01

    It needs to be seamlessly integrated with `EOS`, which has become the de facto disk storage system at CERN. `CTA` and `EOS` integration requires parallel development of features in both software that needs to be **synchronized and systematically tested** on a specific distributed development infrastructure for each commit in the code base. This presentation describes the full gitlab continuous integration work flow that builds, tests, deploys and run system tests of the full software stack in docker containers on our specific kubernetes infrastructure.

  13. EOS suspension test for the assessment of spinal flexibility in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Hirsch, Caroline; Ilharreborde, Brice; Mazda, Keyvan

    2015-07-01

    The assessment of spinal flexibility is essential for the planning of adolescent idiopathic scoliosis (AIS) surgery. Various radiographic methods have been used but none of them has shown any superiority. The new low-dose stereography system EOS (EOS imaging, Paris, France) captures whole body images in a single scan without vertical distortion. EOS is now used in routine clinical use for AIS follow-up. The aim of this study was to prospectively evaluate the feasibility and the reproducibility of a new suspension test during the EOS imaging for the assessment of spinal flexibility in AIS. Fifty AIS patients scheduled for surgery were prospectively included. For each patient, a standard EOS radiograph was obtained, then a suspension test in the EOS and a classic traction test on the cotrel frame were performed. The examinations were compared in terms of radiation exposure, tolerance, mean traction force, and Cobb angle reduction for each curve. Axial and sagittal reductions during suspension were analyzed on three-dimensional EOS reconstructions. The tolerance of the suspension test was lower than the traction test but it was less operator dependent. Radiation exposure was 7 times lower during the suspension test. Cobb angle reductions achieved in the proximal and main curves by the two tests were similar. The traction test achieved greater reduction of the distal curve. Flexibility in the axial plane and in the sagittal plane was analyzed with the suspension test. The reduction in apical rotation was not correlated with the reduction in Cobb angle. The EOS suspension test can be used for the assessment of spinal flexibility in AIS. It gives a global vision of the deformity with new flexibility indices in the axial and sagittal planes.

  14. EOS MLS Lessons Learned: Design Ideas for Safer and Lower Cost Operations

    Science.gov (United States)

    Miller, Dominick

    2012-01-01

    The Earth Observing System (EOS) Microwave Limb Sounder (MLS) is a complex instrument with a front end computer and 32 subsystem computers. MLS is one of four instruments on NASA's EOS Aura spacecraft With almost 8 years in orbit, MLS has a few lessons learned which can be applied during the design phase of future instruments to effect better longevity, more robust operations and a significant cost benefit during operations phase.

  15. Pattern of Eye Injuries in Children in Benin City, Nigeria ...

    African Journals Online (AJOL)

    Pattern of Eye Injuries in Children in Benin City, Nigeria. ... Open Access DOWNLOAD FULL TEXT ... Majority of the eye injuries were lacerations (50%). ... It is also important to educate parents and caregivers on the likely risk of injury that ...

  16. Diagnosing a red eye: an allergy or an infection?

    African Journals Online (AJOL)

    This is a subjective foreign body sensation and ... blood vessels that cover the ocular surface, as well as cellular. Abstract ... 57(1):29-33. Open Access article distributed under the terms of the .... with itching of the eyes being the most apparent feature.2,4. Associated .... Red eye. Medscape [homepage on the Internet. c2015.

  17. Knowledge, Attitude and Practice of Eye Health Care amongst ...

    African Journals Online (AJOL)

    Objective: To evaluate the knowledge, attitude and practice of eye health care amongst doctors in Lagos. Methodology: Open and closed-ended questionnaires were given to respondents. The questionnaire contained information about age, sex, general knowledge as well as practice of eye care. Results: A total of 104 ...

  18. Prospective study of irradiation and magnification on a pelvic imaging: EOS system versus conventional radiography

    International Nuclear Information System (INIS)

    Demoulin, Loic

    2015-01-01

    The pelvic x-ray is essential for the orthopedic practise. Recently, EOS system has been developed with technology to limit irradiation and theoretically not create magnification. The objective of this study was to evaluate the EOS system realizing a pelvic x-ray. All patients who underwent hip replacement between September 2014 and April 2015 have benefited pelvis radiograph with the 2 techniques, after surgery. The size of the head was measured with both techniques and compared to the established size. Irradiation of each technique was listed. A correlation study was carried out with the body mass index (BMI) of the patient. Irradiation was significantly greater with conventional radiography than with the EOS system: PDS of conventional radiography = 15.0 (10.5; 25.2) against the EOS system PDS = 8.2 (7.1; 9.7), p ≤0.0001. It was found a significant correlation between BMI and irradiation, particularly with conventional radiography. About expansion, the EOS system not create any except in 4 cases, unlike the conventional radiograph. The EOS system significantly decreases irradiation in all patients, compared to the conventional radiography, and it do not create magnification when realizing a pelvic x-ray, even in overweight patients [fr

  19. Flexibility analysis in adolescent idiopathic scoliosis on side-bending images using the EOS imaging system.

    Science.gov (United States)

    Hirsch, C; Ilharreborde, B; Mazda, K

    2016-06-01

    Analysis of preoperative flexibility in adolescent idiopathic scoliosis (AIS) is essential to classify the curves, determine their structurality, and select the fusion levels during preoperative planning. Side-bending x-rays are the gold standard for the analysis of preoperative flexibility. The objective of this study was to examine the feasibility and performance of side-bending images taken in the standing position using the EOS imaging system. All patients who underwent preoperative assessment between April 2012 and January 2013 for AIS were prospectively included in the study. The work-up included standing AP and lateral EOS x-rays of the spine, standard side-bending x-rays in the supine position, and standing bending x-rays in the EOS booth. The irradiation dose was measured for each of the tests. Two-dimensional reducibility of the Cobb angle was measured on both types of bending x-rays. The results were based on the 50 patients in the study. No significant difference was demonstrated for reducibility of the Cobb angle between the standing side-bending images with the EOS imaging system and those in the supine position for all types of Lenke deformation. The irradiation dose was five times lower during the EOS bending imaging. The standing side-bending images in the EOS device contributed the same results as the supine images, with five times less irradiation. They should therefore be used in clinical routine. 2. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Differentiation of eosinophilic leukemia EoL-1 cells into eosinophils induced by histone deacetylase inhibitors.

    Science.gov (United States)

    Ishihara, Kenji; Takahashi, Aki; Kaneko, Motoko; Sugeno, Hiroki; Hirasawa, Noriyasu; Hong, JangJa; Zee, OkPyo; Ohuchi, Kazuo

    2007-03-06

    EoL-1 cells differentiate into eosinophils in the presence of n-butyrate, but the mechanism has remained to be elucidated. Because n-butyrate can inhibit histone deacetylases, we hypothesized that the inhibition of histone deacetylases induces the differentiation of EoL-1 cells into eosinophils. In this study, using n-butyrate and two other histone deacetylase inhibitors, apicidin and trichostatin A, we have analyzed the relationship between the inhibition of histone deacetylases and the differentiation into eosinophils in EoL-1 cells. It was demonstrated that apicidin and n-butyrate induced a continuous acetylation of histones H4 and H3, inhibited the proliferation of EoL-1 cells without attenuating the level of FIP1L1-PDGFRA mRNA, and induced the expression of markers for mature eosinophils such as integrin beta7, CCR1, and CCR3 on EoL-1 cells, while trichostatin A evoked a transient acetylation of histones and induced no differentiation into eosinophils. These findings suggest that the continuous inhibition of histone deacetylases in EoL-1 cells induces the differentiation into mature eosinophils.

  1. Mechanism for the differentiation of EoL-1 cells into eosinophils by histone deacetylase inhibitors.

    Science.gov (United States)

    Kaneko, Motoko; Ishihara, Kenji; Takahashi, Aki; Hong, Jangja; Hirasawa, Noriyasu; Zee, Okpyo; Ohuchi, Kazuo

    2007-01-01

    EoL-1 cells have a FIP1L1-PDGFRA fusion gene which causes the transformation of eosinophilic precursor cells into leukemia cells. Recently, we suggested that the induction of differentiation of EoL-1 cells into eosinophils by the HDAC inhibitors apicidin and n-butyrate is due to the continuous inhibition of HDACs. However, neither apicidin nor n-butyrate inhibited the expression of FIP1L1-PDGFRA mRNA, although both these inhibitors suppressed cell proliferation. Therefore, in this study, we analyzed whether the levels of FIP1L1-PDGFRalpha protein and phosphorylated-Stat5 involved in the signaling for the proliferation of EoL-1 cells are attenuated by HDAC inhibitors. EoL-1 cells were incubated in the presence of apicidin, TSA or n-butyrate. FIP1L1-PDGFRalpha and phosphorylated-Stat5 were detected by Western blotting. Treatment of EoL-1 cells with apicidin at 100 nM or n-butyrate at 500 microM decreased the levels of FIP1L1-PDGFRalpha protein and phosphorylated-Stat5, while that with trichostatin A at 30 nM did not. The decrease in the level of FIP1L1-PDGFRalpha protein caused by apicidin and n-butyrate might be one of the mechanisms by which EoL-1 cells are induced to differentiate into eosinophils by these HDAC inhibitors.

  2. Eos and the Youth: A Case of Inverted Roles in Rape

    Science.gov (United States)

    Dipla, Anthi

    This article examines scenes of Eos pursuing/abducting youths on 5th-century Athenian vases. Eos, the personification of Dawn, is the only woman assuming the role of a pursuer in rape. The theme strangely becomes very popular with vase painters to a degree comparable to ephebes pursuing a woman. The iconography of the scenes is systematically analysed and evaluated. All theories explaining the popularity of the theme from its presumable use as a parable for death are considered. Eos is moreover compared to other winged figures in pursuit that are popular in the same period, especially Sphinx and Eros. Conversely, it is illustrated how Eos' pursuits of youths are thoroughly coined on the same model as ephebe rape scenes. These may have been so popular because they expressed prevalent social notions about how women, like animals,would need subduing/taming by the ephebe, future citizen hunters, before they could assume their appropriate place in society. With Eos the hunter becomes the prey of a wild woman, who has transgressed the control limits set by the social system. Eos is promoted as the ultimate model of what a woman should not be.

  3. common bacterial isolates from infected eyes abstract

    African Journals Online (AJOL)

    LIVINGSTON

    to open as a result of the accumulation of exudates during the night. ... Bacteria were isolated most on the eye infections of the conjunctiva 222(66.70%), then the cornea ..... risk after their maternal immunity has disappeared and before their ...

  4. Surgical Eye Removal in Ile‑Ife, Nigeria

    African Journals Online (AJOL)

    Surgical eye removal procedures include evisceration, enucleation, and ... eliminate the risk of sympathetic ophthalmitis in ruptured globes, relieve ... cite this article: ***. This is an open access article distributed under the terms of the Creative.

  5. Organization of eye bank

    International Nuclear Information System (INIS)

    Reddy, S.C.

    1999-01-01

    Comeal transplantation is the only method of combating the blindness due to corneal opacity caused by infections, malnutrition, trauma and hereditary diseases. Comeal blindness is more prevalent in the developing countries. The availability of the donor cornea, trained ophthalmic surgeons and microsurgery facilities are the key factors in restoring vision in-patients with comeal blindness. The eye bank organization is somewhat similar to that of blood bank. The eye bank should be located in a hospital or a medical centre in which a laboratory may be established for the evaluation and storage of donor tissue. The medical director (Ophthalmologist), technician, secretary and public relation officer are the persons who play an important role in the successful organization of eye bank. The function of the eye bank are procurement, assessment, processing, distribution of donor eyes/corneas, training of technicians/doctors, and conducting research related to storage of donor tissue and corneal transplantation. The necessary infrastructure required for the organization of an eye bank include separate accommodation area for the personnel and the laboratory, telephone, computer, refrigerator, laminar air flow hood. Slitlamp, specular microscope, storage media and equipment, instrument for enucleation of donor eyes, and a motor vehicle. The details of responsibilities of the staff of eye bank, source of donor eyes, suitability of donor material, procurement of the donor cornea, tissue assessment, storage and preservation, distribution of donor tissue, and limitation of eye bank will be discussed at the time of presentation

  6. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  7. Eye Disease and Development

    DEFF Research Database (Denmark)

    Andersen, Thomas Barnebeck; Dalgaard, Carl-Johan Lars; Selaya, Pablo

    This research advances the hypothesis that cross-country variation in the historical incidence of eye disease has influenced the current global distribution of per capita income. The theory is that pervasive eye disease diminished the incentive to accumulate skills, thereby delaying the fertility...... transition and the take-off to sustained economic growth. In order to estimate the influence from eye disease incidence empirically, we draw on an important fact from the field of epidemiology: Exposure to solar ultraviolet B radiation (UVB-R) is an underlying determinant of several forms of eye disease...

  8. Inflammation in dry eye.

    Science.gov (United States)

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  9. LASIK eye surgery

    Science.gov (United States)

    ... Assisted In Situ Keratomileusis; Laser vision correction; Nearsightedness - Lasik; Myopia - Lasik ... cornea (curvature) and the length of the eye. LASIK uses an excimer laser (an ultraviolet laser) to ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics ... Services Advocacy Foundation About Subspecialties & More Eye ...

  11. Prevention of Eye Injuries

    OpenAIRE

    Pashby, Tom

    1981-01-01

    In Canada 30,000 people are registered as blind; in one third of these, blindness might have been avoided. Prevention is the key to reducing the number of eye injuries and blind eyes. The role of the family physician in early identification of treatable conditions and in the education of patients is discussed, but responsibility for prevention belongs to all physicians. The success of prevention is seen in the great reduction in eye injuries in industry and sports since eye protectors have be...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ...

  13. NASA's Earth Observing System (EOS): Delivering on the Dream, Today and Tomorrow

    Science.gov (United States)

    Kelly, Angelita C.; Johnson, Patricia; Case, Warren F.

    2010-01-01

    This paper describes the successful operations of NASA's Earth Observing System (EOS) satellites over the past 10 years and the plans for the future. Excellent operations performance has been a key factor in the overall success of EOS. The EOS Program was conceived in the 1980s and began to take shape in the early 1990s. EOS consists of a series of satellites that study the Earth as an interrelated system. It began with the launch of Terra in December 1999, followed by Aqua in May 2002, and Aura in July 2004. A key EOS goal is to provide a long-term continuous data set to enable the science community to develop a better understanding of land, ocean, and atmospheric processes and their interactions. EOS has produced unprecedented amounts of data which are used all over the world free of charge. Mission operations have resulted in data recovery for Terra, Aqua, and Aura that have consistently exceeded mission requirements. The paper describes the ground systems and organizations that control the EOS satellites, capture the raw data, and distribute the processed science data sets. The paper further describes how operations have evolved since 1999. Examples of this evolution include (a) the implementation of new mission safety requirements for orbital debris monitoring; (b) technology upgrades to keep facilities at the state of the art; (c) enhancements to meet changing security requirements; and (d) operations management of the 2 international Earth Observing Constellations of 11 satellites known as the "Morning Constellation" and the "A-Train". The paper concludes with a view into the future based on the latest spacecraft status, lifetime projections, and mission plans.

  14. Short-term memory across eye blinks.

    Science.gov (United States)

    Irwin, David E

    2014-01-01

    The effect of eye blinks on short-term memory was examined in two experiments. On each trial, participants viewed an initial display of coloured, oriented lines, then after a retention interval they viewed a test display that was either identical or different by one feature. Participants kept their eyes open throughout the retention interval on some blocks of trials, whereas on others they made a single eye blink. Accuracy was measured as a function of the number of items in the display to determine the capacity of short-term memory on blink and no-blink trials. In separate blocks of trials participants were instructed to remember colour only, orientation only, or both colour and orientation. Eye blinks reduced short-term memory capacity by approximately 0.6-0.8 items for both feature and conjunction stimuli. A third, control, experiment showed that a button press during the retention interval had no effect on short-term memory capacity, indicating that the effect of an eye blink was not due to general motoric dual-task interference. Eye blinks might instead reduce short-term memory capacity by interfering with attention-based rehearsal processes.

  15. Lymphatics and Lymphangiogenesis in the Eye

    Directory of Open Access Journals (Sweden)

    Shintaro Nakao

    2012-01-01

    Full Text Available Lymphatic is a prerequisite for the maintenance of tissue fluid balance and immunity in the body. A body of evidence also shows that lymphangiogenesis plays important roles in the pathogenesis of diseases such as tumor metastasis and inflammation. The eye was thought to lack lymphatic vessels except for the conjunctiva; however, advances in the field, including the identification of lymphatic endothelial markers (e.g., LYVE-1 or podoplanin and lymphangiogenic factors (e.g., VEGF-C, have revealed the exsitence and possible roles of lymphatics and lymphangiogenesis in the eye. Recent studies have shown that corneal limbus, ciliary body, lacrimal gland, orbital meninges, and extraocular muscles contain lymphatic vessels and that the choroid might have a lymphatic-like system. There is no known lymphatic outflow from the eye. However, several lymphatic channels including uveolymphatic pathway might serve the ocular fluid homeostasis. Furthermore, lymphangiogenesis plays important roles in pathological conditions in the eye including corneal transplant rejection and ocular tumor progression. Yet, the role of lymphangiogenesis in most eye diseases, especially inflammatory disease or edema, remains unknown. A better understanding of lymphatic and lymphangiogenesis in the eye will open new therapeutic opportunities to prevent vision loss in ocular diseases.

  16. Complications of cataract surgery in eyes filled with silicone oil.

    Science.gov (United States)

    Kanclerz, Piotr; Grzybowski, Andrzej; Schwartz, Stephen G; Lipowski, Paweł

    2018-03-01

    The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil. This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal. In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed. In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

  17. Breaking the EOS-gravity degeneracy with masses and pulsating frequencies of neutron stars

    International Nuclear Information System (INIS)

    Lin, Weikang; Li, Bao-An; Chen, Lie-Wen; Wen, De-Hua; Xu, Jun

    2014-01-01

    A thorough understanding of many astrophysical phenomena associated with compact objects requires reliable knowledge about both the equation of state (EOS) of super-dense nuclear matter and the theory of strong-field gravity simultaneously because of the EOS-gravity degeneracy. Currently, variations of the neutron star (NS) mass–radius correlation from using alternative gravity theories are much larger than those from changing the NS matter EOS within known constraints. At least two independent observables are required to break the EOS-gravity degeneracy. Using model EOSs for hybrid stars and a Yukawa-type non-Newtonian gravity, we investigate both the mass–radius correlation and pulsating frequencies of NSs. While the maximum mass of NSs increases, the frequencies of the f, p 1 , p 2 , and w I pulsating modes are found to decrease with the increasing strength of the Yukawa-type non-Newtonian gravity, providing a useful reference for future determination simultaneously of both the strong-field gravity and the supranuclear EOS by combining data of x-ray and gravitational wave emissions of NSs. (paper)

  18. End-of-life (EoL) mobile phone management in Hong Kong households.

    Science.gov (United States)

    Deng, Wen-Jing; Giesy, John P; So, C S; Zheng, Hai-Long

    2017-09-15

    A questionnaire survey and interviews were conducted in households and end-of-life (EoL) mobile phone business centres in Hong Kong. Widespread Internet use, combined with the rapid evolution of modern social networks, has resulted in the more rapid obsolescence of mobile phones, and thus a tremendous increase in the number of obsolete phones. In 2013, the volume of EoL mobile phones generated in Hong Kong totalled at least 330 tonnes, and the amount is rising. Approximately 80% of electronic waste is exported to Africa and developing countries such as mainland China or Pakistan for recycling. However, the material flow of the large number of obsolete phones generated by the territory's households remains unclear. Hence, the flow of EoL mobile phones in those households was analysed, with the average lifespan of a mobile phone in Hong Kong found to be just under two years (nearly 23 months). Most EoL mobile phones are transferred to mainland China for disposal. Current recycling methods are neither environmentally friendly nor sustainable, with serious implications for the environment and human health. The results of this analysis provide useful information for planning the collection system and facilities needed in Hong Kong and mainland China to better manage EoL mobile phones in the future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines ... Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines ...

  20. Eye tracking social preferences

    NARCIS (Netherlands)

    Jiang, Ting; Potters, Jan; Funaki, Yukihiko

    We hypothesize that if people are motivated by a particular social preference, then choosing in accordance with this preference will lead to an identifiable pattern of eye movements. We track eye movements while subjects make choices in simple three-person distribution experiments. We characterize

  1. XI. THE WATERING EYE

    African Journals Online (AJOL)

    cause a watering eye; this condition is.called epiphora. Clearly, then, in investigating ... blockage is a common disease in the middle age-groups seen in hospital .... a dry eye, and this is so much worse than a wet one that the procedure is only ...

  2. Dry eye syndrome

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000426.htm Dry eye syndrome To use the sharing features on this page, ... second-hand smoke exposure Cold or allergy medicines Dry eye can also be caused by: Heat or ... Symptoms may include: Blurred vision Burning, itching, ...

  3. What Is Dry Eye?

    Medline Plus

    Full Text Available ... is also when your eyes do not make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and ...

  4. Photorefraction of the Eye

    Science.gov (United States)

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  5. Lasik eye surgery - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100206.htm Lasik eye surgery - series—Normal anatomy To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Laser Eye Surgery A.D.A.M., Inc. is accredited by ...

  6. About the Eye

    Medline Plus

    Full Text Available ... luh) is the small, sensitive area of the retina needed for central vision. It contains the fovea. Lens is the clear part of the eye behind the iris that helps to focus light on the retina. It allows the eye to focus on both ...

  7. LASIK Eye Surgery

    Science.gov (United States)

    ... at the front of your eye — to improve vision. Normally, images are clearly focused on the retina in the back of your eye because the ... sharply, light rays focus in front of the retina and blur distant vision. You can see objects that are close fairly ...

  8. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job ... Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... also when your eyes do not make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear film is made of three ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society ... Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society ...

  12. Smoking and Eye Health

    Science.gov (United States)

    ... Patient Stories Español Eye Health / Tips & Prevention Sections Smoking and Eye Disease Leer en Español: El cigarrillo ... By: Brenda Pagan-Duran MD Apr. 27, 2017 Smoking contributes to a number of major health problems, ...

  13. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ... Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ...

  14. About the Eye

    Medline Plus

    Full Text Available ... Learn how the different parts of your eye work together so you can see and make sense of the world around you. Did You Know? Vision depends on your brain as much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare ... Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare ...

  16. BullsEye

    DEFF Research Database (Denmark)

    Klokmose, Clemens Nylandsted; Kristensen, Janus Bager; Bagge, Rolf

    2014-01-01

    implemented primarily in shaders on the GPU. The techniques are realized in the BullsEye computer vision software. We demonstrate experimentally that BullsEye provides sub-pixel accuracy down to a tenth of a pixel, which is a significant improvement compared to the commonly used reacTIVision software....

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum ... Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum ...

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and ... Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and ...

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare ... Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare ...

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... bloodshot when I wake up? Jun 26, 2016 Why are my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes when I sleep? Feb 10, 2016 Can light sensitivity from Parkinson’s ...

  1. Apoptosis in the eye.

    OpenAIRE

    Chahory , Sabine; Torriglia , Alicia

    2006-01-01

    Apoptosis is a normal component of the development and health of multicellular organisms. Cells die during apoptosis in a controlled, regulated fashion. This form of cell death is very important in eye development as well as in eye pathology. We review in this chapter our current knowledge in this topic.

  2. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America ... Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America ...

  3. Eyes, Bulging (Proptosis)

    Science.gov (United States)

    ... Early Breast Cancer to Avoid Chemo Could a Blood Test Spot Lung Cancer Early? Experimental Drug Shows 'Modest' Benefit ... often done when bulging affects only one eye. Blood tests to measure how well the thyroid is working are done when ... When bulging leads to severe dry eyes, lubrication with artificial tears is needed to ...

  4. Towards an EO-based Landslide Web Mapping and Monitoring Service

    Science.gov (United States)

    Hölbling, Daniel; Weinke, Elisabeth; Albrecht, Florian; Eisank, Clemens; Vecchiotti, Filippo; Friedl, Barbara; Kociu, Arben

    2017-04-01

    National and regional authorities and infrastructure maintainers in mountainous regions require accurate knowledge of the location and spatial extent of landslides for hazard and risk management. Information on landslides is often collected by a combination of ground surveying and manual image interpretation following landslide triggering events. However, the high workload and limited time for data acquisition result in a trade-off between completeness, accuracy and detail. Remote sensing data offers great potential for mapping and monitoring landslides in a fast and efficient manner. While facing an increased availability of high-quality Earth Observation (EO) data and new computational methods, there is still a lack in science-policy interaction and in providing innovative tools and methods that can easily be used by stakeholders and users to support their daily work. Taking up this issue, we introduce an innovative and user-oriented EO-based web service for landslide mapping and monitoring. Three central design components of the service are presented: (1) the user requirements definition, (2) the semi-automated image analysis methods implemented in the service, and (3) the web mapping application with its responsive user interface. User requirements were gathered during semi-structured interviews with regional authorities. The potential users were asked if and how they employ remote sensing data for landslide investigation and what their expectations to a landslide web mapping service regarding reliability and usability are. The interviews revealed the capability of our service for landslide documentation and mapping as well as monitoring of selected landslide sites, for example to complete and update landslide inventory maps. In addition, the users see a considerable potential for landslide rapid mapping. The user requirements analysis served as basis for the service concept definition. Optical satellite imagery from different high resolution (HR) and very high

  5. Application of the PFV EoS correlation to excess molar volumes of (1-ethyl-3-methylimidazolium ethylsulfate + alkanols) at different temperatures

    International Nuclear Information System (INIS)

    Deenadayalu, N.; Sen, S.; Sibiya, P.N.

    2009-01-01

    The experimental densities for the binary systems of an ionic liquid and an alkanol {1-ethyl-3-methylimidazolium ethylsulfate [EMIM] + [EtSO 4 ] - + methanol or 1-propanol or 2-propanol} were determined at T = (298.15, 303.15, and 313.15) K. The excess molar volumes for the above systems were then calculated from the experimental density values for each temperature. The Redlich-Kister smoothing polynomial was used to fit the experimental results and the partial molar volumes were determined from the Redlich-Kister coefficients. For all the systems studied, the excess molar volume results were negative over the entire composition range for all the temperatures. The excess molar volumes were correlated with the pentic four parameter virial (PFV) equation of state (EoS) model

  6. The EOS imaging system: Workflow and radiation dose in scoliosis examinations

    DEFF Research Database (Denmark)

    Mussmann, Bo; Torfing, Trine; Jespersen, Stig

    Introduction The EOS imaging system is a biplane slot beam scanner capable of full body scans at low radiation dose and without geometrical distortion. It was implemented in our department primo 2012 and all scoliosis examinations are now performed in EOS. The system offers improved possibility...... to measure rotation of individual vertebrae and vertebral curves can be assessed in 3D. Leg length Discrepancy measurements are performed in one exposure without geometrical distortion and no stitching. Full body scans for sagittal balance are also performed with the equipment after spine surgery. Purpose...... The purpose of the study was to evaluate workflow defined as scheduled time pr. examination and radiation dose in scoliosis examinations in EOS compared to conventional x-ray evaluation. Materials and Methods: The Dose Area Product (DAP) was measured with a dosimeter and a comparison between conventional X...

  7. Polystyrene Foam EOS as a Function of Porosity and Fill Gas

    Science.gov (United States)

    Mulford, Roberta; Swift, Damian

    2009-06-01

    An accurate EOS for polystyrene foam is necessary for analysis of numerous experiments in shock compression, inertial confinement fusion, and astrophysics. Plastic to gas ratios vary between various samples of foam, according to the density and cell-size of the foam. A matrix of compositions has been investigated, allowing prediction of foam response as a function of the plastic-to-air ratio. The EOS code CHEETAH allows participation of the air in the decomposition reaction of the foam, Differences between air-filled, nitrogen-blown, and CO2-blown foams are investigated, to estimate the importance of allowing air to react with plastic products during decomposition. Results differ somewhat from the conventional EOS, which are generated from values for plastic extrapolated to low densities.

  8. Tree Canopy Characterization for EO-1 Reflective and Thermal Infrared Validation Studies: Rochester, New York

    Science.gov (United States)

    Ballard, Jerrell R., Jr.; Smith, James A.

    2002-01-01

    The tree canopy characterization presented herein provided ground and tree canopy data for different types of tree canopies in support of EO-1 reflective and thermal infrared validation studies. These characterization efforts during August and September of 2001 included stem and trunk location surveys, tree structure geometry measurements, meteorology, and leaf area index (LAI) measurements. Measurements were also collected on thermal and reflective spectral properties of leaves, tree bark, leaf litter, soil, and grass. The data presented in this report were used to generate synthetic reflective and thermal infrared scenes and images that were used for the EO-1 Validation Program. The data also were used to evaluate whether the EO-1 ALI reflective channels can be combined with the Landsat-7 ETM+ thermal infrared channel to estimate canopy temperature, and also test the effects of separating the thermal and reflective measurements in time resulting from satellite formation flying.

  9. EO-1/Hyperion: Nearing Twelve Years of Successful Mission Science Operation and Future Plans

    Science.gov (United States)

    Middleton, Elizabeth M.; Campbell, Petya K.; Huemmrich, K. Fred; Zhang, Qingyuan; Landis, David R.; Ungar, Stephen G.; Ong, Lawrence; Pollack, Nathan H.; Cheng, Yen-Ben

    2012-01-01

    The Earth Observing One (EO-1) satellite is a technology demonstration mission that was launched in November 2000, and by July 2012 will have successfully completed almost 12 years of high spatial resolution (30 m) imaging operations from a low Earth orbit. EO-1 has two unique instruments, the Hyperion and the Advanced Land Imager (ALI). Both instruments have served as prototypes for NASA's newer satellite missions, including the forthcoming (in early 2013) Landsat-8 and the future Hyperspectral Infrared Imager (HyspIRI). As well, EO-1 is a heritage platform for the upcoming German satellite, EnMAP (2015). Here, we provide an overview of the mission, and highlight the capabilities of the Hyperion for support of science investigations, and present prototype products developed with Hyperion imagery for the HyspIRI and other space-borne spectrometers.

  10. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Directory of Open Access Journals (Sweden)

    Colleen T O'Rourke

    Full Text Available BACKGROUND: Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. METHODOLOGY/PRINCIPAL FINDINGS: We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33° and wide blind areas (∼82°, but intermediate degree of eye movement (∼5°, which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°, small blind areas (∼60°, and high degree of eye movement (∼8°, which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1° may help stabilize the image when hovering above prey before an attack. CONCLUSIONS: We conclude that: (a there are between-species differences in visual field configuration in these diurnal raptors; (b these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats; (c variations in the degree of eye movement between species appear associated with foraging strategies; and (d the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence

  11. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Science.gov (United States)

    O'Rourke, Colleen T; Hall, Margaret I; Pitlik, Todd; Fernández-Juricic, Esteban

    2010-09-22

    Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33°) and wide blind areas (∼82°), but intermediate degree of eye movement (∼5°), which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°), small blind areas (∼60°), and high degree of eye movement (∼8°), which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1°) may help stabilize the image when hovering above prey before an attack. We conclude that: (a) there are between-species differences in visual field configuration in these diurnal raptors; (b) these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats); (c) variations in the degree of eye movement between species appear associated with foraging strategies; and (d) the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence behavioral strategies to visually search for and track prey while

  12. Advocacy for eye care

    Directory of Open Access Journals (Sweden)

    Thulasiraj D Ravilla

    2012-01-01

    Full Text Available The effectiveness of eye care service delivery is often dependant on how the different stakeholders are aligned. These stakeholders range from the ministries of health who have the capacity to grant government subsidies for eye care, down to the primary healthcare workers who can be enrolled to screen for basic eye diseases. Advocacy is a tool that can help service providers draw the attention of key stakeholders to a particular area of concern. By enlisting the support, endorsement and participation of a wider circle of players, advocacy can help to improve the penetration and effectiveness of the services provided. There are several factors in the external environmental that influence the eye care services - such as the availability of trained manpower, supply of eye care consumables, government rules and regulations. There are several instances where successful advocacy has helped to create an enabling environment for eye care service delivery. Providing eye care services in developing countries requires the support - either for direct patient care or for support services such as producing trained manpower or for research and dissemination. Such support, in the form of financial or other resources, can be garnered through advocacy.

  13. Design of a nickel-hydrogen battery simulator for the NASA EOS testbed

    Science.gov (United States)

    Gur, Zvi; Mang, Xuesi; Patil, Ashok R.; Sable, Dan M.; Cho, Bo H.; Lee, Fred C.

    1992-01-01

    The hardware and software design of a nickel-hydrogen (Ni-H2) battery simulator (BS) with application to the NASA Earth Observation System (EOS) satellite is presented. The battery simulator is developed as a part of a complete testbed for the EOS satellite power system. The battery simulator involves both hardware and software components. The hardware component includes the capability of sourcing and sinking current at a constant programmable voltage. The software component includes the capability of monitoring the battery's ampere-hours (Ah) and programming the battery voltage according to an empirical model of the nickel-hydrogen battery stored in a computer.

  14. Guidance, navigation, and control subsystem for the EOS-AM spacecraft

    Science.gov (United States)

    Linder, David M.; Tolek, Joseph T.; Lombardo, John

    1992-01-01

    This paper presents the preliminary design of the Guidance, Navigation, and Control (GN&C) subsystem for the EOS-AM spacecraft and specifically focuses on the GN&C Normal Mode design. First, a brief description of the EOS-AM science mission, instruments, and system-level spacecraft design is provided. Next, an overview of the GN&C subsystem functional and performance requirements, hardware, and operating modes is presented. Then, the GN&C Normal Mode attitude determination, attitude control, and navigation systems are detailed. Finally, descriptions of the spacecraft's overall jitter performance and Safe Mode are provided.

  15. Optimized collection of EoL electronic products for Circular economy: A techno-economic assessment

    DEFF Research Database (Denmark)

    Angouria-Tsorochidou, Elisavet; Cimpan, Ciprian; Parajuly, Keshav

    2018-01-01

    The relevance of a circular model is widely accepted for the lifecycle management of electrical and electronic products (e-products), given the low recovery rates of valuable resources in current end-of-life (EoL) practices focused on recycling. However, missing insight into the technical...... and business potential for alternative EoL options (reuse, repair and remanufacturing) holds stakeholders from implementing circular strategies. In this context, our study first mapped by means of material flow analysis (MFA) the life cycle stages of e-products in Denmark and then performed a preliminary...

  16. Open scientific communication urged

    Science.gov (United States)

    Richman, Barbara T.

    In a report released last week the National Academy of Sciences' Panel on Scientific Communication and National Security concluded that the ‘limited and uncertain benefits’ of controls on the dissemination of scientific and technological research are ‘outweighed by the importance of scientific progress, which open communication accelerates, to the overall welfare of the nation.’ The 18-member panel, chaired by Dale R. Corson, president emeritus of Cornell University, was created last spring (Eos, April 20, 1982, p. 241) to examine the delicate balance between open dissemination of scientific and technical information and the U.S. government's desire to protect scientific and technological achievements from being translated into military advantages for our political adversaries.The panel dealt almost exclusively with the relationship between the United States and the Soviet Union but noted that there are ‘clear problems in scientific communication and national security involving Third World countries.’ Further study of this matter is necessary.

  17. Aquaporins in the Eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Hamann, Steffen; Heegaard, Steffen

    2017-01-01

    The major part of the eye consists of water . Continuous movement of water and ions between the ocular compartments and to the systemic circulation is pivotal for many physiological functions in the eye. The movement of water facilitates removal of the many metabolic products of corneal-, ciliary...... pressure. In the retina, water is transported into the vitreous body and across the retinal pigment epithelium to regulate the extracellular environment and the hydration of the retina. Aquaporins (AQPs ) take part in the water transport throughout the eye....

  18. Trend report Energy Research Subsidy programme (2005-2008). A report on the most important trends and effects since the start of the Energy Research Subsidy (EOS) programme

    International Nuclear Information System (INIS)

    Kimman, J.; Soeriowardojo, E.; Witte, F.; Nijdam, J.

    2009-07-01

    In 2005 the Energy Research Subsidy programme (EOS) was launched in the Netherlands. In four years' time about 500 projects were realized thanks to contributions from EOS. This report provides an overview of the main trends and effects of EOS in the period 2005-2008. One of the main conclusions is that a number of technologies have developed from invention level to market-ready level thanks to the EOS programme. The main trends since the start of EOS are: Increasing confidence of investors in EOS spearheads; increasing activity in EOS spearheads; Spearheads shifting to investment and exploitation schemes; EOS contributes to a solid patent position of Dutch parties; EOS contributes to European research. [nl

  19. A Reference Implementation of the OGC CSW EO Standard for the ESA HMA-T project

    Science.gov (United States)

    Bigagli, Lorenzo; Boldrini, Enrico; Papeschi, Fabrizio; Vitale, Fabrizio

    2010-05-01

    This work was developed in the context of the ESA Heterogeneous Missions Accessibility (HMA) project, whose main objective is to involve the stakeholders, namely National space agencies, satellite or mission owners and operators, in an harmonization and standardization process of their ground segment services and related interfaces. Among HMA objectives was the specification, conformance testing, and experimentation of two Extension Packages (EPs) of the ebRIM Application Profile (AP) of the OGC Catalog Service for the Web (CSW) specification: the Earth Observation Products (EO) EP (OGC 06-131) and the Cataloguing of ISO Metadata (CIM) EP (OGC 07-038). Our contributions have included the development and deployment of Reference Implementations (RIs) for both the above specifications, and their integration with the ESA Service Support Environment (SSE). The RIs are based on the GI-cat framework, an implementation of a distributed catalog service, able to query disparate Earth and Space Science data sources (e.g. OGC Web Services, Unidata THREDDS) and to expose several standard interfaces for data discovery (e.g. OGC CSW ISO AP). Following our initial planning, the GI-cat framework has been extended in order to expose the CSW.ebRIM-CIM and CSW.ebRIM-EO interfaces, and to distribute queries to CSW.ebRIM-CIM and CSW.ebRIM-EO data sources. We expected that a mapping strategy would suffice for accommodating CIM, but this proved to be unpractical during implementation. Hence, a model extension strategy was eventually implemented for both the CIM and EO EPs, and the GI-cat federal model was enhanced in order to support the underlying ebRIM AP. This work has provided us with new insights into the different data models for geospatial data, and the technologies for their implementation. The extension is used by suitable CIM and EO profilers (front-end mediator components) and accessors (back-end mediator components), that relate ISO 19115 concepts to EO and CIM ones. Moreover

  20. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and ... It sends electrical impulses through the optic nerve to the brain. Watch ...

  1. Diabetic Eye Problems

    Science.gov (United States)

    ... damage your eyes. The most common problem is diabetic retinopathy. It is a leading cause of blindness ... You need a healthy retina to see clearly. Diabetic retinopathy damages the tiny blood vessels inside your ...

  2. About the Eye

    Medline Plus

    Full Text Available ... of many different parts that work together to help you see. Check out the diagrams below to ... part of the eye behind the iris that helps to focus light on the retina. It allows ...

  3. About the Eye

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... Clinical Studies Publications Catalog Photos ...

  4. About the Eye

    Medline Plus

    Full Text Available ... Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables ... Optic nerve (OP-tic nurv) is the bundle of more than 1 million nerve fibers that carry visual messages from the retina to ...

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... month dissolvable punctal plug be removed or pushed down the tear duct to insert a permanent punctal ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  6. About the Eye

    Medline Plus

    Full Text Available ... the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical ... System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear ...

  7. Eye Involvement in TSC

    Science.gov (United States)

    ... 50% of the individuals with TSC have normal intelligence, and inasmuch as these individuals may become parents, ... of vision may be difficult or impossible. Since growth and change of TSC lesions in the eye ...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center ... Ophthalmology Guide Find an Ophthalmologist Advanced Search Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation ...

  9. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for ...

  10. Amblyopia: Lazy Eye Treatment

    Science.gov (United States)

    ... with Myopia Aug 31, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 Combating ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  11. Amblyopia: Lazy Eye Diagnosis

    Science.gov (United States)

    ... with Myopia Aug 31, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 Combating ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  13. About the Eye

    Medline Plus

    Full Text Available ... the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M L ... (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to ...

  14. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips ... addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... of tears or tear film . How do tears work? When you blink, a film of tears spreads ... Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy Policy Related Please ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... treated? Jan 28, 2016 Find an Ophthalmologist Advanced Search Ask an Ophthalmologist Browse Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  17. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., Scientific Director David ...

  18. About the Eye

    Medline Plus

    Full Text Available ... Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs ... Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and ...

  19. About the Eye

    Medline Plus

    Full Text Available ... Contact Us Visiting the NIH Campus Mission Statement As part of the federal government’s National Institutes of ... Did You Know? Vision depends on your brain as much as it does on your eyes. NEI ...

  20. About the Eye

    Medline Plus

    Full Text Available ... NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ...

  1. About the Eye

    Medline Plus

    Full Text Available ... about each part of your eye and what it does. Macula (MACK-yoo-luh) is the small, ... area of the retina needed for central vision. It contains the fovea. Lens is the clear part ...

  2. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools ...

  3. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  4. About the Eye

    Medline Plus

    Full Text Available ... Office of the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the ...

  5. Using Eye Makeup

    Science.gov (United States)

    ... harmful chemicals. Before applying makeup, be sure your face and eyelids are very clean. Always apply makeup outside the lash line, away from the eye, to avoid blocking the oil glands of the upper or lower ...

  6. About the Eye

    Medline Plus

    Full Text Available ... Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  7. About the Eye

    Medline Plus

    Full Text Available ... of visual function, preservation of sight, and the special health problems and requirements of the blind.” News & ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  8. About the Eye

    Medline Plus

    Full Text Available ... part of your eye and what it does. Macula (MACK-yoo-luh) is the small, sensitive area ... FOH-vee-uh) is the center of the macula, where your vision is sharpest. Optic nerve (OP- ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists ...

  10. About the Eye

    Medline Plus

    Full Text Available ... 5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  11. Eye and orbit ultrasound

    Science.gov (United States)

    ... Images Head and eye echoencephalogram References Coleman DJ, Silverman RH, Lloyd HO, Daly S. Evaluation of the posterior ... Vision Institute, La Jolla, CA. Also reviewed by David Zieve, MD, MHA, Medical Director, Brenda Conaway, Editorial ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research ... iris adjusts the size of the pupil and controls the amount of light that can enter the ...

  13. About the Eye

    Medline Plus

    Full Text Available ... System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear ... Social Media Policies and Other Important Links NEI Employee Emergency Information NEI Intranet (Employees Only) *PDF files ...

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... information about eye health and preserving your vision. Privacy Policy Related Please Don’t Shave the Inside ... the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Uveitis Focus On Pediatric Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global ... an Ophthalmologist Patient Stories Español Eye Health / ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... of tears or tear film . How do tears work? When you blink, a film of tears spreads ... eyes don’t make enough tears or something affects one or more layers of the tear film. ...

  17. About the Eye

    Medline Plus

    Full Text Available ... Learn how the different parts of your eye work together so you can see and make sense of the world around you. ... Social Media Policies and Other Important Links NEI Employee Emergency Information ...

  18. About the Eye

    Medline Plus

    Full Text Available ... Campus Mission Statement As part of the federal government’s National Institutes of Health (NIH), the National Eye ... Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science ...

  19. About the Eye

    Medline Plus

    Full Text Available ... are made up of many different parts that work together to help you see. Check out the diagrams ... Learn how the different parts of your eye work together so you can see and make sense of ...

  20. About the Eye

    Medline Plus

    Full Text Available ... are made up of many different parts that work together to help you see. Check out the ... Learn how the different parts of your eye work together so you can see and make sense ...

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Care, Part 5 Mar 19, 2013 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry ...

  2. About the Eye

    Medline Plus

    Full Text Available ... History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  3. Fish eye optics

    Czech Academy of Sciences Publication Activity Database

    Hudec, René; Michalová, S.

    2017-01-01

    Roč. 47, č. 2 (2017), s. 94-99 ISSN 1335-1842. [INTEGRAL/BART Workshop /14./. Karlovy Vary, 03.04.2017-07.04.2017] Grant - others:GA ČR(CZ) GA13-33324S Institutional support: RVO:67985815 Keywords : fish eye optics * lobster eye optics * X-ray monitoring Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 0.336, year: 2016

  4. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy Beth; Ellervik, Christina; Buch, Helena

    2016-01-01

    , Danish Rural Eye Study (DRES). All DRES participants received a comprehensive general health examination preceding their eye examination, including measurement of best-corrected visual acuity (BCVA) for each eye, bilateral 45° retinal fundus photographs and further ophthalmological examination where...... indicated. RESULTS: Overall, 3826 of 3843 participants (99.6%) had bilateral visual acuity measurements. The overall frequency of VI (BCVA eye) was 0.4% (95% confidence interval, CI, 0.2-0.7%; n = 15) among all DRES participants, 0.6% (95% CI 0.3-1.0%; n = 15) among participants...... >50 years and 3.7% (95% CI 2.1-6.5%; n = 11) in participants >80 years. The primary causes of VI in the better-seeing eye were age-related macular degeneration (AMD) in 46.7% (7/15) and cataract in 26.7% (4/15). A total of 43.3% (n = 115) of participants >80 years were pseudophakic in one or both eyes...

  5. SensorWeb Evolution Using the Earth Observing One (EO-1) Satellite as a Test Platform

    Science.gov (United States)

    Mandl, Daniel; Frye, Stuart; Cappelaere, Pat; Ly, Vuong; Handy, Matthew; Chien, Steve; Grossman, Robert; Tran, Daniel

    2012-01-01

    The Earth Observing One (EO-1) satellite was launched in November 2000 as a one year technology demonstration mission for a variety of space technologies. After the first year, in addition to collecting science data from its instruments, the EO-1 mission has been used as a testbed for a variety of technologies which provide various automation capabilities and which have been used as a pathfinder for the creation of SensorWebs. A SensorWeb is the integration of variety of space, airborne and ground sensors into a loosely coupled collaborative sensor system that automatically provides useful data products. Typically, a SensorWeb is comprised of heterogeneous sensors tied together with a messaging architecture and web services. This paper provides an overview of the various technologies that were tested and eventually folded into normal operations. As these technologies were folded in, the nature of operations transformed. The SensorWeb software enables easy connectivity for collaboration with sensors, but the side benefit is that it improved the EO-1 operational efficiency. This paper presents the various phases of EO-1 operation over the past 12 years and also presents operational efficiency gains demonstrated by some metrics.

  6. Assimilated ozone from EOS-Aura: Evaluation of the tropopause region and tropospheric columns

    NARCIS (Netherlands)

    Stajner, I.; Wargan, K.; Pawson, S.; Hayashi, H.; Chang, L.-P.; Hudman, R.C.; Froidevaux, L.; Livesey, N.J.; Levelt, P.F.; Thompson, A.M.; Tarasick, D.W.; Stübi, R.; Andersen, S.B.; Yela, M.; König-Langlo, G.; Schmidlin, F.J.; Witte, J.C.

    2008-01-01

    Retrievals from the Microwave Limb Sounder (MLS) and the Ozone Monitoring Instrument (OMI) on EOS-Aura were included in the Goddard Earth Observing System version 4 (GEOS-4) ozone data assimilation system. The distribution and daily to seasonal evolution of ozone in the stratosphere and troposphere

  7. Mission Status for Earth Science Constellation MOWG Meeting at KSC: EOS Aura

    Science.gov (United States)

    Fisher, Dominic

    2017-01-01

    This will be presented at the Earth Science Constellation Mission Operations Working Group (MOWG) meeting at KSC (Kennedy Space Center) in December 2017 to discus EOS (Earth Observing System) Aura status. Reviewed and approved by Eric Moyer, ESMO (Earth Sciences Mission Operations) Deputy Project Manager.

  8. Eosinophilic Esophagitis (EoE: an emerging disease in childhood - Review of diagnostic and management strategies

    Directory of Open Access Journals (Sweden)

    Jorge Amil Dias

    2014-11-01

    Full Text Available Eosinophilic esophagitis (EoE is a chronic immune/antigen mediated inflammatory disease of the esophagus. It comprises a separate entity of increasing incidence and prevalence in children and adults. The disease is characterized by histological evidence of dense esophageal tissue eosinophilia in the presence of a variety of upper GI symptoms including vomiting, dysphagia, food impaction and odynophagia. Cornerstone of treatment is dietary intervention and/or the off-label use of swallowed topical corticosteroids. New drug therapies are under investigation. In this review we focus on the diagnostic approach and the currently available treatment strategies. Keywords: Eosinophilic esophagitis, oral viscous budesonide, fluticasone propionate, oral steroids, amino acid-based formula, empiric elimination diet, targeted elimination dietKey points:1.A trial with antisecretory medication is necessary to exclude GERD and PPI-responsive esophageal eosinophilia and to fulfil the diagnostic criteria of EoE. 2.Elimination diet and/or off-label use of topical corticosteroids are effective measures for treating EoE. 3.Elimination diet is the first line treatment in atopic children. 4.Systemic corticosteroids are reserved for patients with severe disease requiring immediate relief, or when other treatments have failed. 5.Cromolyn sodium (sodium cromoglycate and leukotriene receptor antagonists, are not currently recommended for treating EoE, due to lack of solid evidence of benefit.6.Immunosuppressive drugs and biologics have shown some value but effect has been limited and therefore not yet recommended as standard therapy.

  9. Language Attitudes of Asturian Students in the Area of Navia-Eo (Spain)

    Science.gov (United States)

    González-Riaño, Xosé; Hevia-Artime, Isabel; Fernández-Costales, Alberto

    2013-01-01

    This paper presents a synthesis of a pioneering study that approaches the sociolinguistic and educational reality of the area of Navia-Eo, a region in the western part of Asturias (Spain). This research aims to provide an insight into the language attitudes and the sociolinguistic awareness of students in the final year of primary education. Using…

  10. Terrestrial remote sensing science and algorithms planned for EOS/MODIS

    Science.gov (United States)

    Running, S. W.; Justice, C.O.; Salomonson, V.V.; Hall, D.; Barker, J.; Kaufmann, Y. J.; Strahler, Alan H.; Huete, A.R.; Muller, Jan-Peter; Vanderbilt, V.; Wan, Z.; Teillet, P.; Carneggie, David M. Geological Survey (U.S.) Ohlen

    1994-01-01

    The Moderate Resolution Imaging Spectroradiometer (MODIS) will be the primary daily global monitoring sensor on the NASA Earth Observing System (EOS) satellites, scheduled for launch on the EOS-AM platform in June 1998 and the EOS-PM platform in December 2000. MODIS is a 36 channel radiometer covering 0·415-14·235 μm wavelengths, with spatial resolution from 250 m to 1 km at nadir. MODIS will be the primary EOS sensor for providing data on terrestrial biospheric dynamics and process activity. This paper presents the suite of global land products currently planned for EOSDIS implementation, to be developed by the authors of this paper, the MODIS land team (MODLAND). These include spectral albedo, land cover, spectral vegetation indices, snow and ice cover, surface temperature and fire, and a number of biophysical variables that will allow computation of global carbon cycles, hydrologic balances and biogeochemistry of critical greenhouse gases. Additionally, the regular global coverage of these variables will allow accurate surface change detection, a fundamental determinant of global change.

  11. Template-Independent Enzymatic Oligonucleotide Synthesis (TiEOS): Its History, Prospects, and Challenges.

    Science.gov (United States)

    Jensen, Michael A; Davis, Ronald W

    2018-03-27

    There is a growing demand for sustainable methods in research and development, where instead of hazardous chemicals, an aqueous medium is chosen to perform biological reactions. In this Perspective, we examine the history and current methodology of using enzymes to generate artificial single-stranded DNA. By using traditional solid-phase phosphoramidite chemistry as a metric, we also explore criteria for the method of template-independent enzymatic oligonucleotide synthesis (TiEOS). As its key component, we delve into the biology of one of the most enigmatic enzymes, terminal deoxynucleotidyl transferase (TdT). As TdT is found to exponentially increase antigen receptor diversity in the vertebrate immune system by adding nucleotides in a template-free manner, researchers have exploited this function as an alternative to the phosphoramidite synthesis method. Though TdT is currently the preferred enzyme for TiEOS, its random nucleotide incorporation presents a barrier in synthesis automation. Taking a closer look at the TiEOS cycle, particularly the coupling step, we find it is comprised of additions > n+1 and deletions. By tapping into the physical and biochemical properties of TdT, we strive to further elucidate its mercurial behavior and offer ways to better optimize TiEOS for production-grade oligonucleotide synthesis.

  12. Heavy ion reaction measurements with the EOS TPC (looking for central collisions with missing energy)

    International Nuclear Information System (INIS)

    Wieman, H.H.

    1994-05-01

    The EOS TPC was constructed for complete event measurement of heavy ion collisions at the Bevalac. We report here on the TPC design and some preliminary measurements of conserved event quantities such as total invariant mass, total momentum, total A and Z

  13. 77 FR 59567 - Retrospective Regulatory Review Under E.O. 13563

    Science.gov (United States)

    2012-09-28

    ... #0;notices is to give interested persons an opportunity to participate in #0;the rule making prior to... Immigration Review 8 CFR Parts 1003, 1103, 1208, 1211, 1212, 1215, 1216, 1235 [EOIR No. 178] RIN 1125-AA71 Retrospective Regulatory Review Under E.O. 13563 AGENCY: Executive Office for Immigration Review, Department of...

  14. Thirty Years with EoS/GE Models - What Have We Learned?

    DEFF Research Database (Denmark)

    Kontogeorgis, Georgios M.; Coutsikos, Philippos

    2012-01-01

    Thirty years of research and the use of EoS/GE mixing rules in cubic equations of state are reviewed. The most popular approaches are presented both from the derivation and application points of view and they are compared to each other. It is shown that all methods have significant capabilities b...

  15. Relationship between molecular structure and supramolecular morphology of DODA-EO2-biotin and related lipids

    NARCIS (Netherlands)

    Huetz, P.; van Neuren, S.; Ringler, P.; Kremer, F.; van Breemen, J.F.L.; Wagenaar, A.; Engberts, J.B.F.N.; Fraaije, J.G E M; Brisson, A.

    1997-01-01

    We have recently reported that a biotinylated lipid molecule, called DODA-EO2-biotin, forms tubular lipid structures upon hydration, which act as a matrix for the formation of ordered helical arrays of streptavidin as well as for secondary macromolecular recognition reactions involving biotinylated

  16. 76 FR 47527 - Retrospective Regulatory Review Under E.O. 13563

    Science.gov (United States)

    2011-08-05

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security 15 CFR Chapter VII [Docket No. 110711380-1379-01] RIN 0694-XA37 Retrospective Regulatory Review Under E.O. 13563 AGENCY: Bureau of Industry and Security, Commerce. ACTION: Notice of inquiry. SUMMARY: The Bureau of Industry and Security (BIS...

  17. 76 FR 13931 - Department of State Retrospective Review under E.O. 13563

    Science.gov (United States)

    2011-03-15

    ... DEPARTMENT OF STATE 22 CFR Chapter I 28 CFR Chapter XI [Public Notice: 7351] Department of State Retrospective Review under E.O. 13563 AGENCY: Department of State. ACTION: Request for information and comment. SUMMARY: As part of its implementation of Executive Order 13563, ``Improving Regulation and Regulatory...

  18. 76 FR 78183 - Preliminary Plan for Retrospective Review Under E.O. 13579

    Science.gov (United States)

    2011-12-16

    ... DEPARTMENT OF JUSTICE Parole Commission 28 CFR Part 2 [Docket No. USPC-2011-01] Preliminary Plan for Retrospective Review Under E.O. 13579 AGENCY: United States Parole Commission, Justice. ACTION: Request for comments. SUMMARY: The U.S. Parole Commission is asking for comments on its preliminary plan...

  19. An evaluation of the EOS X-ray imaging system in pelvimetry

    International Nuclear Information System (INIS)

    Sigmann, M.H.; Runge, M.; Peyron, C.; Delabrousse, E.; Riethmuller, D.; Aubry, S.

    2014-01-01

    Objectives: To demonstrate the reliability of the EOS imaging system in measuring the internal diameters of the bony pelvis. Materials and methods: A prospective study comparing the results of the pelvimetry of 18 dry pelvises carried out on the EOS imaging system to measurements taken manually and using the two current gold standard CT methods. Pelvi-metric measurements of each pelvic bone were obtained using four methods and compared: direct manual measurements, spiral and sequential CT pelvimetry, and 2D-3D low-dose bi-planar X-rays. The various obstetric diameters were measured to the millimetre and compared. Results: There was no significant difference in the different diameters assessed, with the exception of the inter-spinous diameter. There was a highly significant correlation (P < 0.001) between the values measured manually and by EOS for the Magnin index (Pearson = 0.98), the obstetric conjugate diameter (Pearson = 0.99), and the median transverse diameter (Pearson = 0.87). Conclusion: The EOS imaging system allows for an ex vivo determination of the obstetrical diameters that is reliable enough to estimate obstetric prognosis, producing comparable measurements to CT. In view of concerns about protection from radiation, this low-dose imaging technique could become, after in vivo prospective validation, the new gold standard for pelvimetry and therefore a good alternative to CT. (authors)

  20. Beyond GIS with EO4V is Trails: a geospatio-temporal scientific workflow environment

    CSIR Research Space (South Africa)

    Van Zyl, T

    2012-10-01

    Full Text Available be accommodated at once. The scientific workflows approach has other advantages to such as provenance, repeatability and collaboration. The paper presents EO4VisTrails as an example of such a scientific workflows approach to integration and discusses the benefit...

  1. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.

  2. Future Perspective and Long-Term Strategy of the Indian EO Programme

    Science.gov (United States)

    Rao, Mukund; Jayaraman, V.; Sridhara Murthi, K. R.; Kasturirangan, K.

    EO technology development will continue to have profound effects on spatial information activities, as we are seeing it today - the changing demand of GIS technology to understanding processes around us and its representation as maps. In the longer term, information needs will drive further RS and GIS technological developments - creating stringent demands for technology solutions for spatial data capture, integration and representation. The emergence of Spatial Business from the highly volatile and dynamic synergy of information, technology and access will see a truly Spatial Society. EO will have a major impact on day-to-day life of nations, communities and even an individual. It will become the One-stop source for information - spatial information at that - thus enabling not only development oriented activities but also Business GIS, quality research and Info-savvy communities. Internationally, there will be a mix of Government and Commercial satellites vying to provide information services to a wide variety of users. EO satellites are also becoming smaller, efficient and less costlier. Almost 5-6 commercial systems will orbit around the Earth in the foreseeable future to generate massive, seamless archives of high-resolution panchromatic and multispectral images - almost reducing the need for aerial surveys for photography and mapping. Reaching resolution of cm level and covering narrower and more spectral bands, the trend is to IMAGE the Earth in its entirety and organize Image Infrastructures. The race will be to imaginatively capture the market with the fullest archive of the globe and cater to any imaging demand of users. One will also see efficient satellite operations that will enable imaging any part of the globe with minimum turn-around time - reaching concepts of IMAGING ON DEMAND. The need of the hour is looking forward now towards how the EO technology can adapt itself to the changing scenario and the steps to be taken to sustain use of EO data it in

  3. Eyes wide shut: amygdala mediates eyes-closed effect on emotional experience with music.

    Science.gov (United States)

    Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma

    2009-07-15

    The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, 'low', visceral-, and 'high', cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. 'low') and cognitive (i.e. 'high') related processes of emotions.

  4. The first observation of EO transitions from negative parity states in even-even nucleus 160Dy

    International Nuclear Information System (INIS)

    Grigoriev, E.P.

    1988-01-01

    In even-even deformed nuclei up to now EO-transitions were found only between the states of the same spin belonging to Κ π = O + rotational bands. There is no forbidenness for EO-transitions between states belonging to bands with any other quantum number Κ provided both initial and final states have the same J π Κ values. EO-transitions may depopulate odd-parity states. In odd nuclei β-vibrational states are identified by transition with EO-components. Here transitions also proceed between states with the same J π K numbers. Even-even nuclide 160 Dy is the first nucleus where the EO-transitions between odd-parity states have been found

  5. Comparative cross-sectional study of empathy among first year and final year medical students in Jimma University, Ethiopia: Steady state of the heart and opening of the eyes

    Directory of Open Access Journals (Sweden)

    Dehning Sandra

    2012-05-01

    Full Text Available Abstract Background There is general consent that empathy is crucial for the physician-patient relationship and thus an important issue in medical education. This comparative study was designed to examine the differences in empathy between first year and final year medical students in Jimma University, Ethiopia. Methods A comparative cross-sectional study among 131 first year and 106 final year medical students was conducted in Jimma University, Ethiopia on academic year 2010/11. The study subjects were selected using simple random sampling technique from the list of the students. Study participation was voluntary. The Balanced Emotional Empathy Scale (BEES was used for the detection of “heart-reading”, i.e. emotional empathy and the Reading the Mind in the Eyes test (RME-R test to evaluate “mind-reading”, i.e. cognitive empathy. We performed t-test to compare the mean difference in empathy and RME-R scores between the two groups of students. A linear regression was computed to identify potential factors influencing the BEES and RME-R. Results Out of the total 237 students, 207 (87.3% were males. The mean age of first year and final year students was 19.3 ± 1.1 and 24.0 ± 1.4 years respectively. First year students have scored 40.6 ± 23.8 while final year students scored 41.5 ± 20.8 mean in the BEES measuring emotional empathy score. However, this difference was not statistically significant (t = −0.30, df = 231, P-value >0.05. Final year students had significantly higher mean cognitive empathy score (17.8 ± 4.5 than first year students (14.4 ± 4.8 [β = 2.7, 95%CI (1.20, 4.13]. Males had scored lower cognitive [β = −2.5, 95%CI (−4.37, −0.66] and emotional empathy [β = −12.0, 95%CI (−21.66, −5.46]. Conclusions Low emotional (BEES and cognitive empathy sores were found in first year and final year students of Jimma University could have implications on the medical

  6. NASA's "Eyes" Focus on Education

    Science.gov (United States)

    Hussey, K.

    2016-12-01

    NASA's "Eyes on…" suite of products continues to grow in capability and popularity. The "Eyes on the Earth", "Eyes on the Solar System" and "Eyes on Exoplanets" real-time, 3D interactive visualization products have proven themselves as highly effective demonstration and communication tools for NASA's Earth and Space Science missions. This presentation will give a quick look at the latest updates to the "Eyes" suite plus what is being done to make them tools for STEM Education.

  7. Autologous serum eye drops for dry eye

    Science.gov (United States)

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  8. ASSESSMENT OF FUNCTIONAL CHANGES TEAR PRODUCTION UNDER THE ACTION OF THE EYE DROPS ON THE BASE OF NATURAL MOLECULE OF ECTOINE AND ARTIFICIAL TEARS IN PATIENTS WITH DRY EYE SYNDROME ON THE BACKGROUND OF ENDOCRINE OPHTHALMOPATHY.

    Science.gov (United States)

    Veselovskaya, N N; Zherebko, I B

    Conducted a comparative analysis of functional changes in tear production in patients with dry eye syndrome and endocrine ophthalmopathy in the conditions of the long-term acting of preservative free medications based on natural substances. A total of 30 people, aged 35 to 53 years old with clinical manifestations of DES on the background of EO were divided on two groups. In I group eye drops of ectoine and in II - artificial tears were administered. The examination included general and specific methods. The term of follow up - 30 days. It was found that long-term use of preservative free eye drops based on ectoine leads to more expressive positive changes in the condition of the anterior surface of the eye and the secretion and quality of the tear.

  9. Leaf area index retrieval using Hyperion EO-1 data-based vegetation indices in Himalayan forest system

    Science.gov (United States)

    Singh, Dharmendra; Singh, Sarnam

    2016-04-01

    Present Study is being taken to retrieve Leaf Area Indexn(LAI) in Himalayan forest system using vegetation indices developed from Hyperion EO-1 hyperspectral data. Hemispherical photograph were captured in the month of March and April, 2012 at 40 locations, covering moist tropical Sal forest, subtropical Bauhinia and pine forest and temperate Oak forest and analysed using an open source GLA software. LAI in the study region was ranging in between 0.076 m2/m2 to 6.00 m2/m2. These LAI values were used to develop spectral models with the FLAASH corrected Hyperion measurements.Normalized difference vegetation index (NDVI) was used taking spectral reflectance values of all the possible combinations of 170 atmospherically corrected channels. The R2 was ranging from lowest 0.0 to highest 0.837 for the band combinations of spectral region 640 nm and 670 nm. The spectral model obtained was, spectral reflectance (y) = 0.02x LAI(x) - 0.0407.

  10. What We Have Learned with 16 Years of EO-1 Hyperion

    Science.gov (United States)

    Ungar, S.

    2016-12-01

    The Earth Observing-One (EO-1) satellite, launched in November of 2000, will complete its sixteenth and final year of operation at the end of calendar year 2016. Observations from the Hyperion Imaging Spectrometer on board EO-1 have contributed to hundreds of papers in refereed journals, conference proceeds and other presentations. The EO-1 Hyperion imaging spectrometer is the first and longest operating instrument that provides visible to shortwave infrared science-grade data from orbit. Hyperion has been used to study a variety of natural and anthropogenic phenomena including hazards and catastrophes, agricultural health and productivity, ecological disturbance/development, and land use/land cover change. As an example, Hyperion has been used in hazard and catastrophe studies to monitor and assess effects of tsunamis, earthquakes, volcanic eruptions, mudslides, tornadoes, hurricanes, wild-fires (natural and human ignited), oil spills, and the aftermath of world trade center bombing. This presentation summarizes the current status of EO-1 Hyperion in terms of key scientific findings to date and presents future plans for exploiting the upward of 90,000 scenes expected to be archived at USGS EROS by the end of the mission. Hyperion serves as the heritage orbital spectrometer for future global platforms, including the proposed NASA Hyperspectral Infrared Imager (HyspIRI) and the forthcoming German satellite, EnMAP. A key EO-1 mission goal was to evaluate the ability of satellite high spectral resolution imaging to characterize terrestrial surface state and processes at 30 m resolution. Researchers engaged in NASA's Terrestrial Ecology, Carbon Science, Land Use Change and other programs using the EO-1 Hyperion imaging spectrometer have achieved results with accuracies far exceeding those reached with the current spaceborne fleet of multispectral sensors. Hyperion data provide several advantages over data from multispectral satellite systems: they inherently provide

  11. King and Eye

    DEFF Research Database (Denmark)

    Suwannakij, Sing

    King and Eye explores the visual formation of kingship in Siam in its multifarious aspects. This dissertation identifies the leitmotifs in the dynamics between seeing the king and being seen by him, which burst forth in different eras. The visual sense has been a repository for the ontologization...... devices, most significantly the photographic and the cine cameras, but also encompassing other ocular apparatuses. The images produced through the contraptions were brought together under the royal eye at the apex, which in turn claimed its supremacy over space, time, and the vast and diverse population...

  12. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Ellervik, Christina

    2015-01-01

    and older from a Danish rural municipality received a complete general health examination and an ophthalmological interview and examination. This study included a comprehensive ophthalmologic interview, measurement of best corrected visual acuity (BCVA) in each eye, Hirschberg's test for strabismus and two...... 45-degree retinal fundus photographs of each eye. A complete ophthalmologic examination was performed when indicated. RESULTS: The prevalence of monocular visual impairment (MVI) was 4.26% (95% CI, 3.66-4.95, n = 163). Amblyopia was the most common cause, accounting for 33%. The prevalence...

  13. Mesoscopic Simulations of the Phase Behavior of Aqueous EO 19 PO 29 EO 19 Solutions Confined and Sheared by Hydrophobic and Hydrophilic Surfaces

    KAUST Repository

    Liu, Hongyi; Li, Yan; Krause, Wendy E.; Pasquinelli, Melissa A.; Rojas, Orlando J.

    2012-01-01

    The MesoDyn method is used to investigate associative structures in aqueous solution of a nonionic triblock copolymer consisting of poly(propylene oxide) capped on both ends with poly(ethylene oxide) chains. The effect of adsorbing (hydrophobic) and nonadsorbing (hydrophilic) solid surfaces in contact with aqueous solutions of the polymer is elucidated. The macromolecules form self-assembled structures in solution. Confinement under shear forces is investigated in terms of interfacial behavior and association. The formation of micelles under confinement between hydrophilic surfaces occurs faster than in bulk aqueous solution while layered structures assemble when the polymers are confined between hydrophobic surfaces. Micelles are deformed under shear rates of 1 μs -1 and eventually break to form persistent, adsorbed layered structures. As a result, surface damage under frictional forces is prevented. Overall, this study indicates that aqueous triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO) (Pluronics, EO mPO nEO m) act as a boundary lubricant for hydrophobic surfaces but not for hydrophilic ones. © 2011 American Chemical Society.

  14. Mesoscopic Simulations of the Phase Behavior of Aqueous EO 19 PO 29 EO 19 Solutions Confined and Sheared by Hydrophobic and Hydrophilic Surfaces

    KAUST Repository

    Liu, Hongyi

    2012-01-25

    The MesoDyn method is used to investigate associative structures in aqueous solution of a nonionic triblock copolymer consisting of poly(propylene oxide) capped on both ends with poly(ethylene oxide) chains. The effect of adsorbing (hydrophobic) and nonadsorbing (hydrophilic) solid surfaces in contact with aqueous solutions of the polymer is elucidated. The macromolecules form self-assembled structures in solution. Confinement under shear forces is investigated in terms of interfacial behavior and association. The formation of micelles under confinement between hydrophilic surfaces occurs faster than in bulk aqueous solution while layered structures assemble when the polymers are confined between hydrophobic surfaces. Micelles are deformed under shear rates of 1 μs -1 and eventually break to form persistent, adsorbed layered structures. As a result, surface damage under frictional forces is prevented. Overall, this study indicates that aqueous triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO) (Pluronics, EO mPO nEO m) act as a boundary lubricant for hydrophobic surfaces but not for hydrophilic ones. © 2011 American Chemical Society.

  15. EO-Performance relationships in Reverse Internationalization by Chinese Global Startup OEMs: Social Networks and Strategic Flexibility

    Science.gov (United States)

    Chin, Tachia; Tsai, Sang-Bing; Fang, Kai; Zhu, Wenzhong; Yang, Dongjin; Liu, Ren-huai; Tsuei, Richard Ting Chang

    2016-01-01

    Due to the context-sensitive nature of entrepreneurial orientation (EO), it is imperative to in-depth explore the EO-performance mechanism in China at its critical, specific stage of economic reform. Under the context of “reverse internationalization” by Chinese global startup original equipment manufacturers (OEMs), this paper aims to manifest the unique links and complicated interrelationships between the individual EO dimensions and firm performance. Using structural equation modeling, we found that during reverse internationalization, proactiveness is positively related to performance; risk taking is not statistically associated with performance; innovativeness is negatively related to performance. The proactiveness-performance relationship is mediated by Strategic flexibility and moderated by social networking relationships. The dynamic and complex institutional setting, coupled with the issues of overcapacity and rising labor cost in China may explain why our distinctive results occur. This research advances the understanding of how contingent factors (social network relationships and strategic flexibility) facilitate entrepreneurial firms to break down institutional barriers and reap the most from EO. It brings new insights into how Chinese global startup OEMs draw on EO to undertake reverse internationalization, responding the calls for unraveling the heterogeneous characteristics of EO sub-dimensions and for more contextually-embedded treatment of EO-performance associations. PMID:27631368

  16. EO-Performance relationships in Reverse Internationalization by Chinese Global Startup OEMs: Social Networks and Strategic Flexibility.

    Science.gov (United States)

    Chin, Tachia; Tsai, Sang-Bing; Fang, Kai; Zhu, Wenzhong; Yang, Dongjin; Liu, Ren-Huai; Tsuei, Richard Ting Chang

    2016-01-01

    Due to the context-sensitive nature of entrepreneurial orientation (EO), it is imperative to in-depth explore the EO-performance mechanism in China at its critical, specific stage of economic reform. Under the context of "reverse internationalization" by Chinese global startup original equipment manufacturers (OEMs), this paper aims to manifest the unique links and complicated interrelationships between the individual EO dimensions and firm performance. Using structural equation modeling, we found that during reverse internationalization, proactiveness is positively related to performance; risk taking is not statistically associated with performance; innovativeness is negatively related to performance. The proactiveness-performance relationship is mediated by Strategic flexibility and moderated by social networking relationships. The dynamic and complex institutional setting, coupled with the issues of overcapacity and rising labor cost in China may explain why our distinctive results occur. This research advances the understanding of how contingent factors (social network relationships and strategic flexibility) facilitate entrepreneurial firms to break down institutional barriers and reap the most from EO. It brings new insights into how Chinese global startup OEMs draw on EO to undertake reverse internationalization, responding the calls for unraveling the heterogeneous characteristics of EO sub-dimensions and for more contextually-embedded treatment of EO-performance associations.

  17. Esophagectomy - open

    Science.gov (United States)

    ... Lewis esophagectomy, Blunt esophagectomy; Esophageal cancer - esophagectomy - open; Cancer of the esophagus - esophagectomy - open ... lining of the esophagus that can lead to cancer ( Barrett esophagus ) Severe trauma Destroyed esophagus Severely damaged stomach

  18. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  19. Acanthamoeba Keratitis at the King Khaled Eye Specialist Hospital

    International Nuclear Information System (INIS)

    Al-Mezaine, H.; Al-Muteb, M.; Al-Motowa, S.; Wagoner, M. D.

    2005-01-01

    To quantify the number of cases and clinical courses of Acanthamoeba keratitis treated at the King Khaled Eye Specialist Hospital (KKESH) between December 1982 and May 2005, and to review their clinical course and response to medical and surgical therapy. Retrospective review of medical records of all patients with Acanthamoeba keratitis diagnosed by the KKESH Microbiology or Pathology or Pathology Laboratory since the opening of the hospital. During a period of over 22 years, only six cases of confirmed. Acanthamoeba keratitis were diagnosedand treated at KKESH. In two cases the diagnosis was made by corneal biopsy, while four cases required examination of a histopathology specimen obtained at the time of therapeutic keratoplasty to establish the diagnosis. One eye was cured by medical therapy, while five eyes required one (4eyes) or two (1 eye) therapeutic penetrating keratoplasty (PKP) to achieve a clinical cure. Three eyes achieved good visual acuity (20/40, 20/50, 20/60), one eye achieved fair visual acuity (20/160), and two eyes suffered profound visual loss (hand motions). The incidence of Acanthamoeba keratitis may be less in Saudi Arabia than reported in Western countries although the clinical is similarly complicated, with most cases requiring therapeutic keratoplasty for definitive education of the organism. (author)

  20. Open access

    NARCIS (Netherlands)

    Valkenburg, P.M.

    2015-01-01

    Open access week Van 19 tot en met 25 oktober 2015 vond wereldwijd de Open Access Week plaats. Tijdens deze week werden er over de hele wereld evenementen georganiseerd waar open access een rol speelt. Ook in Nederland zijn er diverse symposia, workshops en debatten georganiseerd zoals het debat in

  1. EoR imaging with the SKA: the challenge of foreground removal

    Science.gov (United States)

    Bonaldi, Anna

    2018-05-01

    21-cm observations of the Cosmic dawn (CD) and Epoch of Reionization (EoR) are one of the high priority science objectives for SKA Low. One of the most difficult aspects of the 21-cm measurement is the presence of foreground emission, due to our Galaxy and extragalactic sources, which is about four orders of magnitude brighter than the cosmological signal. While end-to-end simulations are being produced to investigate in details the foreground subtraction strategy, it is useful to complement this thorough but time-consuming approach with simpler, quicker ways to evaluate performance and identify possible critical steps. In this work, I present a forecast method, based on Bonaldi et al. (2015), Bonaldi & Ricciardi (2011), to understand the level of residual contamination after a component separation step, and its impact on our ability to investigate CD and EoR.

  2. Current Status of the LOFAR EoR Key Science Project

    Science.gov (United States)

    Koopmans, L. V. E.; LOFAR EoR KSP Team

    2018-05-01

    A short status update on the LOFAR Epoch of Reionization (EoR) Key Science Project (KSP) is given, regarding data acquisition, data processing and analysis, and current power-spectrum limits on the redshifted 21-cm signal of neutral hydrogen at redshifts z = 8 - 10. With caution, we present a preliminary astrophysical analysis of ~60 hr of processed LOFAR data and their resulting power spectrum, showing that potentially already interesting limits on X-ray heating during the Cosmic Dawn can already be gained. This is by no means the final analysis of this sub-set of data, but illustrates the future potential when all nearly 3000 hr of data in hand on two EoR windows will have been processed.

  3. Sustained lasing of HHG-seeded FEL by using EOS-based timing control

    International Nuclear Information System (INIS)

    Watanabe, Takahiro; Okayasu, Yuichi; Togashi, Tadashi; Hara, Toru; Tomizawa, Hiromitsu; Matsubara, Shinichi; Aoyama, Makoto; Yamakawa, Koichi; Iwasaki, Atsushi; Ohwada, Shigeki; Sato, Takahiro; Yamauchi, Kaoru; Otake, Yuji; Ohshima, Takashi; Ogawa, Kanade; Togawa, Kazuaki; Tanaka, Takashi; Takahashi, Eiji; Midorikawa, Katsumi; Yabashi, Makina; Tanaka, Hitoshi; Ishikawa, Tetsuya

    2013-01-01

    High-harmonic-generation (HHG) based seeded FEL experiments were demonstrated at SCSS, SPring-8. Seeded FEL has advantageous features against SASE such that there is no intrinsic nature of shot-noise fluctuation and output FEL pulses are in principle fully coherent in both transverse and longitudinal axes. In practical user experiments, however, an overlap between electron bunches and seed laser pulses in six-dimensional phase space needs to be precisely maintained for securing the stable lasing. Otherwise, the overlap could be quickly lost and the lasing is no more sustained. For the stable lasing, we have developed an EO (electro-optic) based timing control system, which enables to observe a timing drift between electron bunches and laser pulses, and compensate for it. Experimental results of the seeded FEL with and without the EO timing control are compared, and the effectiveness of the timing system is discussed. (author)

  4. Expanding NASA's Land, Atmosphere Near Real-Time Capability for EOS (LANCE)

    Science.gov (United States)

    Davies, Diane; Michael, Karen; Masuoka, Ed; Ye, Gang; Schmaltz, Jeffrey; Harrison, Sherry; Ziskin, Daniel; Durbin, Phil B; Protack, Steve; Rinsland, Pamela Livingstone; hide

    2017-01-01

    NASA's Land, Atmosphere Near real-time Capability for EOS (LANCE) is a virtual system that provides near real-time EOS data and imagery to meet the needs of scientists and application users interested in monitoring a wide variety of natural and man-made phenomena in near real-time. Over the last year: near real-time data and imagery from MOPITT, MISR, OMPS and VIIRS (Land and Atmosphere), the Fire Information for Resource Management System (FIRMS) has been updated and LANCE has begun the process of integrating the Global NRT flood, and Black Marble products. In addition, following the AMSU-A2 instrument anomaly in September 2016, AIRS-only products have replaced the NRT level 2 AIRS+AMSU products. This presentation provides a brief overview of LANCE, describes the new products that are recently available and contains a preview of what to expect in LANCE over the coming year.

  5. Organ dose and effective dose with the EOS scanner in spine deformity surgery

    DEFF Research Database (Denmark)

    Heide Pedersen, Peter; Petersen, Asger Greval; Eiskjær, Søren Peter

    2016-01-01

    Organ dose and effective dose with the EOS scanner in spine deformity surgery. A study on anthropomorphic phantoms describing patient radiation exposure in full spine examinations. Authors: Peter Heide Pedersen, Asger Greval Petersen, Søren Peter Eiskjær. Background: Ionizing radiation potentially...... quality images while at the same time reducing radiation dose. At our institution we use the EOS for pre- and postoperative full spine examinations. Purpose: The purpose of the study is to make first time organ dose and effective dose evaluations with micro-dose settings in full spine examinations. Our...... hypothesis is that organ dose and effective doses can be reduced 5-10 times compared to standard settings, without too high image-quality trade off, resulting in a theoretical reduction of radiation induced cancer. Methods: Patient dosimetry is performed on anthropomorphic child phantoms, representing a 5...

  6. 21SSD: a new public 21-cm EoR database

    Science.gov (United States)

    Eames, Evan; Semelin, Benoît

    2018-05-01

    With current efforts inching closer to detecting the 21-cm signal from the Epoch of Reionization (EoR), proper preparation will require publicly available simulated models of the various forms the signal could take. In this work we present a database of such models, available at 21ssd.obspm.fr. The models are created with a fully-coupled radiative hydrodynamic simulation (LICORICE), and are created at high resolution (10243). We also begin to analyse and explore the possible 21-cm EoR signals (with Power Spectra and Pixel Distribution Functions), and study the effects of thermal noise on our ability to recover the signal out to high redshifts. Finally, we begin to explore the concepts of `distance' between different models, which represents a crucial step towards optimising parameter space sampling, training neural networks, and finally extracting parameter values from observations.

  7. An interpretation of the behavior of EoS/GE models for asymmetric systems

    DEFF Research Database (Denmark)

    Kontogeorgis, Georgios; Panayiotis, Vlamos

    2000-01-01

    or zero pressure or at other conditions (system's pressure, constant volume packing fraction). In a number of publications over the last years, the achievements and the shortcomings of the various EoS/G(E) models have been presented via phase equilibrium calculations. This short communication provides...... an explanation of several literature EoSIGE models, especially those based on zero-reference pressure (PSRK, MHV1, MHV2), in the prediction of phase equilibria for asymmetric systems as well as an interpretation of the LCVM and kappa-MHV1 models which provide an empirical - yet as shown here theoretically...... justified - solution to these problems. (C) 2000 Elsevier Science Ltd. All rights reserved....

  8. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and ... is the center of the macula, where your vision is sharpest. Optic nerve (OP-tic nurv) is the bundle of more than 1 ...

  9. Eye Injuries in Construction

    Science.gov (United States)

    ... cold helps keep down pain and swelling. If pain continues or your vision is blurry, get to a doctor right away. ! If you get hit in the eye with flying metal, wood, or material from a power tool (like a drill or wheel) , OR ! If ...

  10. Robustifying eye interaction

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Hansen, John Paulin

    2006-01-01

    This paper presents a gaze typing system based on consumer hardware. Eye tracking based on consumer hardware is subject to several unknown factors. We propose methods using robust statistical principles to accommodate uncertainties in image data as well as in gaze estimates to improve accuracy. We...

  11. About the Eye

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us Visiting the NIH Campus Mission Statement As part ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  13. About the Eye

    Medline Plus

    Full Text Available ... of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., ... David M. Schneeweis, Ph.D., Deputy Scientific Director Office of the Clinical Director Brian P. Brooks, M. ...

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear ...

  15. LASIK - Laser Eye Surgery

    Science.gov (United States)

    ... Refractive Surgery Procedures What Is Photorefractive Keratectomy (PRK)? LASIK — Laser Eye Surgery Leer en Español: LASIK—Cirugía ocular con láser ... loss of close-up focusing power. How the LASIK procedure works LASIK is performed while the patient ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear film ...

  17. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... Employee Emergency Information NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. ...

  18. Eyes on the Road

    Centers for Disease Control (CDC) Podcasts

    One of the first lessons new drivers learn is to keep their eyes on the road. Unfortunately, cell phones and other electronic devices are causing many drivers to lose their focus, and sometimes their lives. In this podcast, Rebecca Naumann discusses the dangers of distracted driving.

  19. The Learned Eye

    NARCIS (Netherlands)

    Doel, van den Marieke; Eck, van Natasja; Korevaar, Gerbrand; Tummers, Anna; Weststeijn, Thijs

    2005-01-01

    The 'learned eye' or oculus eruditus was a concept used by seventeenth-century writers on painting. It illustrated their view that the ideal artist was not only skilled in painting techniques, but also had knowledge of the history of art and an interest in poetry and literature.In this book,

  20. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is ...

  1. Laser photocoagulation - eye

    Science.gov (United States)

    ... an eye disorder that slowly destroys sharp, central vision A tear in the retina A blockage of the small veins that carry ... Since parts of the retina are burned, you may develop: Mild loss ... vision If not treated, diabetic retinopathy can cause permanent ...

  2. About the Eye

    Medline Plus

    Full Text Available ... with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  3. About the Eye

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  4. Eye Cosmetic Safety

    Science.gov (United States)

    ... you're wearing? In the United States, the use of color additives is strictly regulated. A number of color ... to color additives that are not approved for use in the area of the eye. Avoid color additives that are not approved for use in ...

  5. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  6. About the Eye

    Medline Plus

    Full Text Available ... blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ...

  7. About the Eye

    Medline Plus

    Full Text Available ... the white outer coating of the eye. Vitreous humor (VIT-ree-us HYOO-mer) is the clear ... in Spanish (Información en español) Website, Social Media Policies and Other Important Links NEI Employee Emergency Information ...

  8. Inter-eye comparison of retinal oximetry and vessel caliber between eyes with asymmetrical glaucoma severity in different glaucoma subtypes

    Directory of Open Access Journals (Sweden)

    Cheng CS

    2016-07-01

    Full Text Available Clarissa Shu Ming Cheng,1,2 Yi Fang Lee,2 Charles Ong,3 Zhu Li Yap,2 Andrew Tsai,2 Aditi Mohla,2 Monisha E Nongpiur,4 Tin Aung,2,4 Shamira A Perera2,4 1Department of Ophthalmology, Tan Tock Seng Hospital, 2Department of Ophthalmology, Singapore National Eye Centre, 3Yong Loo Lin School of Medicine, National University of Singapore, 4Singapore Eye Research Institute, Singapore National Eye Centre, Singapore Background: To compare retinal vessel oxygenation and vessel caliber in primary angle-closure glaucoma (PACG, primary open-angle glaucoma (POAG, normal-tension glaucoma (NTG, and normal controls, as well as between eyes of asymmetrical glaucoma severity.Methods: This was a prospective, cross-sectional study. The 159 subjects (PACG, n=39; POAG, n=41; NTG, n=41; normal controls, n=38 underwent retinal oxygen saturation measurements using the Oxymap T1 Retinal Oximeter, optical coherence tomography, and Humphrey visual field testing. Retinal oxygen saturation and vessel diameter were compared between the glaucoma groups and normal controls, as well as between eyes of asymmetrical glaucoma severity. Kruskal–Wallis test was performed for comparison among different subtypes of glaucoma. Wilcoxon signed-rank test was used to compare the inter-eye differences.Results: Compared to normal controls, arteriolar oxygen saturation was increased in PACG eyes (P=0.048 but not in POAG or NTG eyes. There were no significant differences in oxygen saturation in venules or arteriovenous (AV difference in all three glaucoma groups. Venular diameter was significantly reduced in all glaucoma groups compared to normal controls (P<0.001, but no such change was observed in arteriolar diameter (P=0.10. When comparing between eyes of asymmetrical glaucoma severity, arteriolar oxygen saturation (P=0.03 and AV difference (P=0.04 were significantly higher, while arteriolar diameter was significantly lower (P=0.001 in the worse eye in PACG group. There were no significant

  9. The Development of Two Science Investigator-led Processing Systems (SIPS) for NASA's Earth Observation System (EOS)

    Science.gov (United States)

    Tilmes, Curt

    2004-01-01

    In 2001, NASA Goddard Space Flight Center's Laboratory for Terrestrial Physics started the construction of a science Investigator-led Processing System (SIPS) for processing data from the Ozone Monitoring Instrument (OMI) which will launch on the Aura platform in mid 2004. The Ozone Monitoring Instrument (OMI) is a contribution of the Netherlands Agency for Aerospace Programs (NIVR) in collaboration with the Finnish Meteorological Institute (FMI) to the Earth Observing System (EOS) Aura mission. It will continue the Total Ozone Monitoring System (TOMS) record for total ozone and other atmospheric parameters related to ozone chemistry and climate. OMI measurements will be highly synergistic with the other instruments on the EOS Aura platform. The LTP previously developed the Moderate Resolution Imaging Spectrometer (MODIS) Data Processing System (MODAPS), which has been in full operations since the launches of the Terra and Aqua spacecrafts in December, 1999 and May, 2002 respectively. During that time, it has continually evolved to better support the needs of the MODIS team. We now run multiple instances of the system managing faster than real time reprocessings of the data as well as continuing forward processing. The new OMI Data Processing System (OMIDAPS) was adapted from the MODAPS. It will ingest raw data from the satellite ground station and process it to produce calibrated, geolocated higher level data products. These data products will be transmitted to the Goddard Distributed Active Archive Center (GDAAC) instance of the Earth Observing System (EOS) Data and Information System (EOSDIS) for long term archive and distribution to the public. The OMIDAPS will also provide data distribution to the OMI Science Team for quality assessment, algorithm improvement, calibration, etc. We have taken advantage of lessons learned from the MODIS experience and software already developed for MODIS. We made some changes in the hardware system organization, database and

  10. Evaluation of software based redundancy algorithms for the EOS storage system at CERN

    International Nuclear Information System (INIS)

    Peters, Andreas-Joachim; Sindrilaru, Elvin Alin; Zigann, Philipp

    2012-01-01

    EOS is a new disk based storage system used in production at CERN since autumn 2011. It is implemented using the plug-in architecture of the XRootD software framework and allows remote file access via XRootD protocol or POSIX-like file access via FUSE mounting. EOS was designed to fulfill specific requirements of disk storage scalability and IO scheduling performance for LHC analysis use cases. This is achieved by following a strategy of decoupling disk and tape storage as individual storage systems. A key point of the EOS design is to provide high availability and redundancy of files via a software implementation which uses disk-only storage systems without hardware RAID arrays. All this is aimed at reducing the overall cost of the system and also simplifying the operational procedures. This paper presents the advantages and disadvantages of redundancy by hardware (most classical storage installations) in comparison to redundancy by software. The latter is implemented in the EOS system and achieves its goal by spawning data and parity stripes via remote file access over nodes. The gain in redundancy and reliability comes with a trade-off in the following areas: • Increased complexity of the network connectivity • CPU intensive parity computations during file creation and recovery • Performance loss through remote disk coupling An evaluation and performance figures of several redundancy algorithms are presented for dual parity RAID and Reed-Solomon codecs. Moreover, the characteristics and applicability of these algorithms are discussed in the context of reliable data storage systems.

  11. Prediction of detonation and JWL eos parameters of energetic materials using EXPLO5 computer code

    CSIR Research Space (South Africa)

    Peter, Xolani

    2016-09-01

    Full Text Available Ballistic Organization Cape Town, South Africa 27-29 September 2016 1 PREDICTION OF DETONATION AND JWL EOS PARAMETERS OF ENERGETIC MATERIALS USING EXPLO5 COMPUTER CODE X. Peter*, Z. Jiba, M. Olivier, I.M. Snyman, F.J. Mostert and T.J. Sono.... Nowadays many numerical methods and programs are being used for carrying out thermodynamic calculations of the detonation parameters of condensed explosives, for example a BKW Fortran (Mader, 1967), Ruby (Cowperthwaite and Zwisler, 1974) TIGER...

  12. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  13. The refinement of ipsilateral eye retinotopic maps is increased by removing the dominant contralateral eye in adult mice.

    Directory of Open Access Journals (Sweden)

    Spencer L Smith

    2010-03-01

    Full Text Available Shortly after eye opening, initially disorganized visual cortex circuitry is rapidly refined to form smooth retinotopic maps. This process asymptotes long before adulthood, but it is unknown whether further refinement is possible. Prior work from our lab has shown that the retinotopic map of the non-dominant ipsilateral eye develops faster when the dominant contralateral eye is removed. We examined whether input from the contralateral eye might also limit the ultimate refinement of the ipsilateral eye retinotopic map in adults. In addition, we examined whether the increased refinement involved the recruitment of adjacent cortical area.By surgically implanting a chronic optical window over visual cortex in mice, we repeatedly measured the degree of retinotopic map refinement using quantitative intrinsic signal optical imaging over four weeks. We removed the contralateral eye and observed that the retinotopic map for the ipsilateral eye was further refined and the maximum magnitude of response increased. However, these changes were not accompanied by an increase in the area of responsive cortex.Since the retinotopic map was functionally refined to a greater degree without taking over adjacent cortical area, we conclude that input from the contralateral eye limits the normal refinement of visual cortical circuitry in mice. These findings suggest that the refinement capacity of cortical circuitry is normally saturated.

  14. EOS MLS Level 1B Data Processing, Version 2.2

    Science.gov (United States)

    Perun, Vincent; Jarnot, Robert; Pickett, Herbert; Cofield, Richard; Schwartz, Michael; Wagner, Paul

    2009-01-01

    A computer program performs level- 1B processing (the term 1B is explained below) of data from observations of the limb of the Earth by the Earth Observing System (EOS) Microwave Limb Sounder (MLS), which is an instrument aboard the Aura spacecraft. This software accepts, as input, the raw EOS MLS scientific and engineering data and the Aura spacecraft ephemeris and attitude data. Its output consists of calibrated instrument radiances and associated engineering and diagnostic data. [This software is one of several computer programs, denoted product generation executives (PGEs), for processing EOS MLS data. Starting from level 0 (representing the aforementioned raw data, the PGEs and their data products are denoted by alphanumeric labels (e.g., 1B and 2) that signify the successive stages of processing.] At the time of this reporting, this software is at version 2.2 and incorporates improvements over a prior version that make the code more robust, improve calibration, provide more diagnostic outputs, improve the interface with the Level 2 PGE, and effect a 15-percent reduction in file sizes by use of data compression.

  15. Modification of Peng Robinson EOS for modelling (vapour + liquid) equilibria with electrolyte solutions

    International Nuclear Information System (INIS)

    Baseri, Hadi; Lotfollahi, Mohammad Nader

    2011-01-01

    Highlights: → Extended PR-EOS was presented for VLE of H 2 O/Salt/CO 2 systems at high pressure. → The proposed EPR-EOS is based upon contributions to the Helmholtz energy. → Born, Margules, and Debye-Huckel or mean spherical approximation terms were used. → Two different mixing rules Panagiotopoulos and Reid and Kwak and Mansoori (KM) were used. → A combination of KM mixing rule with DH term results more accurate VLE results. - Abstract: A modification of the extended Peng-Robinson equation of state (PR-EOS) is presented to describe the (vapour + liquid) equilibria of systems containing water and salts. The modification employs three additional terms including a Born term, a Margules term and two terms separately used for estimation of the long-range electrostatic interactions (the Debye-Huckel (DH) or the mean spherical approximation (MSA) terms). Effects of two mixing rules, first, the Panagiotopoulos and Reid mixing rule (PR) and, second, the Kwak and Mansoori mixing rule (KM), on the final values of VLE calculations are also investigated. The results show that the KM mixing rule is more appropriate than the PR mixing rule. The proposed equation of state is used to calculate the (vapour + liquid) equilibrium (VLE) of the systems containing (water + sodium sulphate + carbon dioxide) and (water + sodium chloride + carbon dioxide) at high pressure. The comparison of calculated results with the experimental data shows that a combination of KM mixing rule with the DH term results a more accurate VLE values.

  16. The effect of tributyltin on human eosinophilic [correction of eosinophylic] leukemia EoL-1 cells.

    Science.gov (United States)

    Sroka, Jolanta; Włosiak, Przemysław; Wilk, Anna; Antonik, Justyna; Czyz, Jarosław; Madeja, Zbigniew

    2008-01-01

    Organotin compounds are chemicals that are widely used in industry and agriculture as plastic stabilizers, catalysts and biocides. Many of them, including tributyltin (TBT), have been detected in human food and, as a consequence, detectable levels have been found in human blood. As organotin compounds were shown to possess immunotoxic activity, we focused our attention on the effect of TBT on the basic determinants of the function of eosinophils, i.e. cell adhesiveness and motility. We used human eosinophylic leukemia EoL-1 cells, a common in vitro cellular model of human eosinophils. Here, we demonstrate that TBT causes a dose-dependent decrease in the viability of EoL-1 cells. When administered at sub-lethal concentrations, TBT significantly decreases the adhesion of EoL-1 cells to human fibroblasts (HSFs) and inhibits their migration on fibroblast surfaces. Since the basic function of eosinophils is to invade inflamed tissues, our results indicate that TBT, and possibly other organotin compounds, may affect major cellular properties involved in the determination of in vivo eosinophil function.

  17. Earth Observing System (EOS) Aqua Launch and Early Mission Attitude Support Experiences

    Science.gov (United States)

    Tracewell, D.; Glickman, J.; Hashmall, J.; Natanson, G.; Sedlak, J.

    2003-01-01

    The Earth Observing System (EOS) Aqua satellite was successfully launched on May 4,2002. Aqua is the second in the series of EOS satellites. EOS is part of NASA s Earth Science Enterprise Program, whose goals are to advance the scientific understanding of the Earth system. Aqua is a three-axis stabilized, Earth-pointing spacecraft in a nearly circular, sun-synchronous orbit at an altitude of 705 km. The Goddard Space Flight Center (GSFC) Flight Dynamics attitude team supported all phases of the launch and early mission. This paper presents the main results and lessons learned during this period, including: real-time attitude mode transition support, sensor calibration, onboard computer attitude validation, response to spacecraft emergencies, postlaunch attitude analyses, and anomaly resolution. In particular, Flight Dynamics support proved to be invaluable for successful Earth acquisition, fine-point mode transition, and recognition and correction of several anomalies, including support for the resolution of problems observed with the MODIS instrument.

  18. Conjunctivitis (Pink Eye) in Newborns

    Science.gov (United States)

    ... as well as the sexually transmitted infection called gonorrhea. Women with untreated gonorrhea can pass the bacteria to her baby during ... conjunctivitis is less common than conjunctivitis caused by gonorrhea and chlamydia. Symptoms usually include red eye(s) and ...

  19. Open Content in Open Context

    Science.gov (United States)

    Kansa, Sarah Whitcher; Kansa, Eric C.

    2007-01-01

    This article presents the challenges and rewards of sharing research content through a discussion of Open Context, a new open access data publication system for field sciences and museum collections. Open Context is the first data repository of its kind, allowing self-publication of research data, community commentary through tagging, and clear…

  20. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    2010-10-12

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.  Created: 10/12/2010 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 10/13/2010.

  1. Neuropathic pain and dry eye.

    Science.gov (United States)

    Galor, Anat; Moein, Hamid-Reza; Lee, Charity; Rodriguez, Adriana; Felix, Elizabeth R; Sarantopoulos, Konstantinos D; Levitt, Roy C

    2018-01-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. Its epidemiology and clinical presentation have many similarities with neuropathic pain outside the eye. This review highlights the similarities between dry eye and neuropathic pain, focusing on clinical features, somatosensory function, and underlying pathophysiology. Implications of these similarities on the diagnosis and treatment of dry eye are discussed. Published by Elsevier Inc.

  2. Moving eyes and naming objects

    NARCIS (Netherlands)

    Meulen, F.F. van der

    2001-01-01

    The coordination between eye movements and speech was examined while speakers were naming objects. Earlier research has shown that eye movements reflect on the underlying visual attention. Also, eye movements were found to reflect upon not only the visual and conceptual processing of an object, but

  3. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    Science.gov (United States)

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  4. Eye Protection in Kansas Schools.

    Science.gov (United States)

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  5. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Weak openness and almost openness

    Directory of Open Access Journals (Sweden)

    David A. Rose

    1984-01-01

    Full Text Available Weak openness and almost openness for arbitrary functions between topological spaces are defined as duals to the weak continuity of Levine and the almost continuity of Husain respectively. Independence of these two openness conditions is noted and comparison is made between these and the almost openness of Singal and Singal. Some results dual to those known for weak continuity and almost continuity are obtained. Nearly almost openness is defined and used to obtain an improved link from weak continuity to almost continuity.

  7. Earth Observing System (EOS)/ Advanced Microwave Sounding Unit-A (AMSU-A): Special Test Equipment. Software Requirements

    Science.gov (United States)

    Schwantje, Robert

    1995-01-01

    This document defines the functional, performance, and interface requirements for the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A) Special Test Equipment (STE) software used in the test and integration of the instruments.

  8. Berkeley Lab's Saul Perlmutter wins E.O. Lawrence Award; scientist's work on supernovae reveals accelerating Universe

    CERN Multimedia

    2002-01-01

    Saul Perlmutter, from Lawrence Berkeley National Laboratory Physics Division and leader of the Supernova Cosmology Project based there, has won the DOE's 2002 E.O. Lawrence Award in the physics category (2 pages).

  9. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  10. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    Science.gov (United States)

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  11. Nutrition and the eye.

    Science.gov (United States)

    Congdon, N G; West, K P

    1999-12-01

    The topic "nutrition and the eye" cannot adequately be covered in a single review article; indeed, dozens of books and hundreds of articles have been written on the subject. This review concentrates on three areas in which specific nutrients are known or theorized to have a major impact on vision and the visual system: vitamin A deficiency; antioxidants and their proposed role in the prevention of age-related cataract and macular degeneration; and nutritional optic neuropathies, including those of the recent Cuban epidemic. In addition, this article touches on nutritional treatments that have been suggested for several less common eye diseases and, finally, considers several less prevalent conditions in which deficiency of or excess exposure to a particular nutrient has been associated with ocular pathology.

  12. Managing eye injuries

    Directory of Open Access Journals (Sweden)

    Dorothy Mutie

    2016-01-01

    Full Text Available Based on what you found during the eye examination, classify the injury as a non-mechanical injury (chemical or thermal injury, a non-globe injury (orbital or adnexal injury or as a mechanical globe injury. In the case of mechanical globe injuries, it is important to classify the injury according to the Birmingham Eye Trauma Terminology System (BETTS and write it down in the patient’s notes; this will help to ensure that everyone involved in caring for the patient will have a consistent understanding of the type of injury. The resulting uniformity of terminology also helps with research, making it possible to compare data and do audits of injuries – which is essential for prevention.

  13. Through the creator's eyes

    DEFF Research Database (Denmark)

    Glaveanu, Vlad Petre; Lahlou, Saadi

    2012-01-01

    of an adapted Subjective Evidence-Based Ethnography (SEBE). This methodology combines (a) obtaining first person audio-visual recordings of creative action with a miniature video-camera worn at eye-level, (b) accessing the subjective experience of the participant through a confrontation interview based...... of creativity at both process and content levels. The benefits, limitations, and possible applications of the method are considered in the broader context of creativity studies....

  14. SU-E-I-15: Comparison of Radiation Dose for Radiography and EOS in Adolescent Scoliosis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B; Walz-Flannigan, A [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: To estimate patient radiation dose for whole spine imaging using EOS, a new biplanar slot-scanning radiographic system and compare with standard scoliosis radiography. Methods: The EOS imaging system (EOS Imaging, Paris, France) consists of two orthogonal x-ray fan beams which simultaneously acquire frontal and lateral projection images of a standing patient. The patient entrance skin air kerma was measured for each projection image using manufacturer-recommended exposure parameters for spine imaging. Organ and effective doses were estimated using a commercially-available Monte Carlo simulation program (PCXMC, STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland) for a 15 year old mathematical phantom model. These results were compared to organ and effective dose estimated for scoliosis radiography using computed radiography (CR) with standard exposure parameters obtained from a survey of pediatric radiographic projections. Results: The entrance skin air kerma for EOS was found to be 0.18 mGy and 0.33 mGy for posterior-anterior (PA) and lateral projections, respectively. This compares to 0.76 mGy and 1.4 mGy for CR, PA and lateral projections. Effective dose for EOS (PA and lateral projections combined) is 0.19 mSv compared to 0.51 mSv for CR. Conclusion: The EOS slot-scanning radiographic system allows for reduced patient radiation dose in scoliosis patients as compared to standard CR radiography.

  15. Christoph Scheiner's eye studies.

    Science.gov (United States)

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century.

  16. Differences of accommodative responses between two eyes under binocular viewing condition mediated by polarizing glasses

    Directory of Open Access Journals (Sweden)

    Rui-Qing Wang

    2016-04-01

    Full Text Available AIM:To study the differences of accommodative responses between the two eyes under 3 different polarized viewing conditions. METHODS:Fifteen volunteers with emmetrope were recruited into this study(aged 18~38, 6 males and 9 females. Three different viewing conditions were set up by using polarizing glasses and liquid crystal display:(1right eye could see the visual target on the screen, but left eye cannot see it;(2left eye could see the visual target on the screen, but right eye cannot see it;(3both eyes could see the target. Accommodative responses were measured by infrared auto-refractor when fixating at the target at 5, 2, 1, 0.5 and 0.33m under the above 3 viewing conditions. The differences of accommodative responses under different viewing conditions were compared by using variance analysis of repeated measuring and t test. RESULTS:Significant differences of accommodative responses between the two eyes were found under condition(1and(2at all the fixating distance. The accommodative responses in used eyes which can see the visual target were higher than in non-used eyes which cannot see the visual target(PP>0.05. CONCLUSION:Ciliary muscles in the used eyes were more relatively tonic than non-used eyes under binocular open viewing condition. The imbalance of accommodative responses between two eyes may be one of the risk factors resulting into the occurrence of myopia.

  17. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  18. Open hardware for open science

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    Inspired by the open source software movement, the Open Hardware Repository was created to enable hardware developers to share the results of their R&D activities. The recently published CERN Open Hardware Licence offers the legal framework to support this knowledge and technology exchange.   Two years ago, a group of electronics designers led by Javier Serrano, a CERN engineer, working in experimental physics laboratories created the Open Hardware Repository (OHR). This project was initiated in order to facilitate the exchange of hardware designs across the community in line with the ideals of “open science”. The main objectives include avoiding duplication of effort by sharing results across different teams that might be working on the same need. “For hardware developers, the advantages of open hardware are numerous. For example, it is a great learning tool for technologies some developers would not otherwise master, and it avoids unnecessary work if someone ha...

  19. Open Access

    Science.gov (United States)

    Suber, Peter

    2012-01-01

    The Internet lets us share perfect copies of our work with a worldwide audience at virtually no cost. We take advantage of this revolutionary opportunity when we make our work "open access": digital, online, free of charge, and free of most copyright and licensing restrictions. Open access is made possible by the Internet and copyright-holder…

  20. Open innovation

    DEFF Research Database (Denmark)

    Bogers, Marcel; Chesbrough, Henry; Moedas, Carlos

    2018-01-01

    Open innovation is now a widely used concept in academia, business, and policy making. This article describes the state of open innovation at the intersection of research, practice, and policy. It discusses some key trends (e.g., digital transformation), challenges (e.g., uncertainty...

  1. Low Cost vs. High-End Eye Tracking for Usability Testing

    DEFF Research Database (Denmark)

    Johansen, Sune Alstrup; San Agustin, Javier; Jensen, Henrik Tomra Skovsgaard Hegner

    2011-01-01

    Accuracy of an open source remote eye tracking system and a state-of-the-art commercial eye tracker was measured 4 times during a usability test. Results from 9 participants showed both devices to be fairly stable over time, but the commercial tracker was more accurate with a mean error of 31 pix...

  2. Does Eye Color Depend on Gender? It Might Depend on Who or How You Ask

    Science.gov (United States)

    Froelich, Amy G.; Stephenson, W. Robert

    2013-01-01

    As a part of an opening course survey, data on eye color and gender were collected from students enrolled in an introductory statistics course at a large university over a recent four year period. Biologically, eye color and gender are independent traits. However, in the data collected from our students, there is a statistically significant…

  3. System and Method for Eye Tracking

    DEFF Research Database (Denmark)

    2017-01-01

    A method and system for monitoring the motion of one or both eyes, includes capturing a sequence of overlapping images of a subject's face including an eye and the corresponding non-eye region; identifying a plurality of keypoints in each image; mapping corresponding keypoints in two or more images...... of the sequence; assigning the keypoints to the eye and to the corresponding non-eye region; calculating individual velocities of the corresponding keypoints in the eye and the corresponding non-eye region to obtain a distribution of velocities; extracting at least one velocity measured for the eye and at least...... one velocity measured for the corresponding non-eye region; calculating the eye-in-head velocity for the eye based upon the measured velocity for the eye and the measured velocity for the corresponding non-eye region; and calculating the eye-in-head position based upon the eye- in-head velocity....

  4. Noninvasive Dry Eye Assessment Using High-Technology Ophthalmic Examination Devices.

    Science.gov (United States)

    Yamaguchi, Masahiko; Sakane, Yuri; Kamao, Tomoyuki; Zheng, Xiaodong; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-11-01

    Recently, the number of dry eye cases has dramatically increased. Thus, it is important that easy screening, exact diagnoses, and suitable treatments be available. We developed 3 original and noninvasive assessments for this disorder. First, a DR-1 dry eye monitor was used to determine the tear meniscus height quantitatively by capturing a tear meniscus digital image that was analyzed by Meniscus Processor software. The DR-1 meniscus height value significantly correlated with the fluorescein meniscus height (r = 0.06, Bland-Altman analysis). At a cutoff value of 0.22 mm, sensitivity of the dry eye diagnosis was 84.1% with 90.9% specificity. Second, the Tear Stability Analysis System was used to quantitatively measure tear film stability using a topographic modeling system corneal shape analysis device. Tear film stability was objectively and quantitatively evaluated every second during sustained eye openings. The Tear Stability Analysis System is currently installed in an RT-7000 autorefractometer and topographer to automate the diagnosis of dry eye. Third, the Ocular Surface Thermographer uses ophthalmic thermography for diagnosis. The decrease in ocular surface temperature in dry eyes was significantly greater than that in normal eyes (P eye opening. Decreased corneal temperature correlated significantly with the tear film breakup time (r = 0.572; P dry eye, sensitivity was 0.83 and specificity was 0.80 after 10 seconds. This article describes the details and potential of these 3 noninvasive dry eye assessment systems.

  5. Keeping Our Eyes Open: Conducting Aerial Reconnaissance Without Space

    Science.gov (United States)

    2016-05-01

    TIMOTHY M. CULLEN (Date) ___________________________________ JAMES M. TUCCI (Date) iii DISCLAIMER The...in 2014/15, and USAF School of Advanced Air and Space Studies in 2015/16. v ACKNOWLEDGMENTS I would like to thank Colonel Timothy Cullen for...Admiral William Owens. In 1996 Owens described ISR as involving “sensor and reporting technologies associated with intelligence collection

  6. The eunuchs of India: An endocrine eye opener

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2012-01-01

    Full Text Available There are established guidelines for the endocrine and overall treatment of transsexual persons. These guidelines provide information about the optimal endocrine management of male-to-female and female-to-male transsexual persons. India has a large community of eunuchs, also known as hijras, who are men with gender identity disorders. While this community has been studied from a social and medical point of new, no endocrine work has been done in them. This exploratory article tries to discuss the endocrine status, health, and management of the eunuchs.

  7. The Chernobyl accident, a catastrophe or an eye-opener?

    International Nuclear Information System (INIS)

    Baarli, J.

    1989-01-01

    The Chernobyl accident is reviewed as to its cause, the way it was handled locally and the consequenses from released radioactivity. It is emphasized that the exposure from the released radioactivity, as to the effective dose equivalent and the committed dose equivalent is small and comparable with the dose equivalent from natural ionizing radiation near the accident, and only a few per cent of this value at more remote distances. It is concluded that the accident probably has been one of the greatest psychological catastrophes that we so far has experienced, but not so when referring to early deaths or radiation damage directly to individuals

  8. Introduction to Eye-Opening Technology: The Electromagnetic Spectrum.

    Science.gov (United States)

    Smith, Denise; Eisenhamer, Bonnie; DeVore, Edna; Bianchi, Luciana

    2003-01-01

    Provides classroom activities centered around how the electromagnetic spectrum yields vital insights about the evolution of the universe. Activities targeted for grade levels 6-12 illustrate the importance of light and color in space exploration. Includes a poster. (Author/SOE)

  9. Impact of eye detection error on face recognition performance

    NARCIS (Netherlands)

    Dutta, A.; Günther, Manuel; El Shafey, Laurent; Veldhuis, Raymond N.J.; Spreeuwers, Lieuwe Jan

    2015-01-01

    The locations of the eyes are the most commonly used features to perform face normalisation (i.e. alignment of facial features), which is an essential preprocessing stage of many face recognition systems. In this study, the authors study the sensitivity of open source implementations of five face

  10. Feeding value of processed horse eye bean ( Mucuna urens ) meal ...

    African Journals Online (AJOL)

    The study was designed to evaluate the performance of pullet chicks fed graded levels of processed horse eye bean meal (HEBM) as partial replacement for soybean meal. The cracked beans were subjected to three processing methods viz: soaking in plain water for 48 hours, cooking for 90 minutes, and toasting on open ...

  11. Pseudoexfoliation Glaucoma in the National Eye Center, Cicendo Eye Hospital, January–October 2012

    Directory of Open Access Journals (Sweden)

    Rizki Fasa Ramdhani

    2015-03-01

    Full Text Available Background: Pseudoexfoliation syndrome is characterized by the deposition of a distinctive fibrillar material in the anterior segment of the eye. This condition is a major risk factor for development of glaucoma, termed pseudoexfoliation glaucoma (PEXG. The aim of this study was to describe the characteristic and management of PEXG in the National Eye Center Cicendo Eye Hospital. Methods: A descriptive retrospective study was conducted in October–November 2012 using medical records of PEXG patients in the National Eye Center Cicendo Eye Hospital during January–October 2012. Results: There were 32 patients (43 eyes diagnosed as PEXG, most of them were male (78.1%, age 70–74 years old (34.4% and followed by those in the range of age 65–69 years old (21.9%. Most of the cases were unilateral (65.6% decrease of visual acuity less than 3/60 (76.7%, increase of intraocular pressure (IOP with majority in the range of 31–40 mmHg (32.6% and 41–50 mmHg (32.6%, Cup/Disc Ratio 0.9–1.0 (46.51% and followed by those classified as majority which were hard to assess because of the presence of opaque media (34.89%. The type of glaucoma was open angle glaucoma (88.4%. The treatment received was a combination of two types of antiglaucoma medication and surgery IOP Conclusion: PEXG is mostly found in elderly patients. While most of the patients come with high IOP and late stage of the disease IOP

  12. A cross-sectional study of the actual use of eye drops in a Saudi ...

    African Journals Online (AJOL)

    and storage of eye drops, and the participants' understanding of the role of pharmacist in enhancing ... This is an Open Access article that uses a funding model which does not charge readers .... to minimise the risks and optimise the potential.

  13. EOS simulation and GRNN modeling of the constant volume depletion behavior of gas condensate reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Elsharkawy, A.M.; Foda, S.G. [Kuwait University, Safat (Kuwait). Petroleum Engineering Dept.

    1998-03-01

    Currently, two approaches are being used to predict the changes in retrograde gas condensate composition and estimate the pressure depletion behavior of gas condensate reservoirs. The first approach uses the equation of states whereas the second uses empirical correlations. Equations of states (EOS) are poor predictive tools for complex hydrocarbon systems. The EOS needs adjustment against phase behavior data of reservoir fluid of known composition. The empirical correlation does not involve numerous numerical computations but their accuracy is limited. This study presents two general regression neural network (GRNN) models. The first model, GRNNM1, is developed to predict dew point pressure and gas compressibility at dew point using initial composition of numerous samples while the second model, GRNNM2, is developed to predict the changes in well stream effluent composition at any stages of pressure depletion. GRNNM2 can also be used to determine the initial reservoir fluid composition using dew point pressure, gas compressibility at dew point, and reservoir temperature. These models are based on analysis of 142 sample of laboratory studies of constant volume depletion (CVD) for gas condensate systems forming a total of 1082 depletion stages. The database represents a wide range of gas condensate systems obtained worldwide. The performance of the GRNN models has been compared to simulation results of the equation of state. The study shows that the proposed general regression neural network models are accurate, valid, and reliable. These models can be used to forecast CVD data needed for many reservoir engineering calculations in case laboratory data is unavailable. The GRNN models save computer time involved in EOS calculations. The study also show that once these models are properly trained they can be used to cut expenses of frequent sampling and laborious experimental CVD tests required for gas condensate reservoirs. 55 refs., 13 figs., 6 tabs.

  14. Enhanced Formation Flying for the Earth Observing-1 (EO-1) New Millennium Mission

    Science.gov (United States)

    Folta, David; Quinn, David

    1997-01-01

    With scientific objectives for Earth observation programs becoming more ambitious and spacecraft becoming more autonomous, the need for new technical approaches on the feasibility of achieving and maintaining formations of spacecraft has come to the forefront. The trend to develop small low cost spacecraft has led many scientists to recognize the advantage of flying several spacecraft in formation, an example of which is shown in the figure below, to achieve the correlated instrument measurements formerly possible only by flying many instruments on a single large platform. Yet, formation flying imposes additional complications on orbit maintenance, especially when each spacecraft has its own orbit requirements. However, advances in automation proposed by GSFC Codes 550 and 712 allow more of the burden in maneuver planning and execution to be placed onboard the spacecraft, mitigating some of the associated operational concerns. The purpose of this analysis is to develop the fundamentals of formation flying mechanics, concepts for understanding the relative motion of free flying spacecraft, and an operational control theory for formation maintenance of the Earth Observing-1 (EO-l) spacecraft that is part of the New Millennium. Results of this development can be used to determine the appropriateness of formation flying for a particular case as well as the operational impacts. Applications to the Mission to Planet Earth (MTPE) Earth Observing System (EOS) and New Millennium (NM) were highly considered in analysis and applications. This paper presents the proposed methods for the guidance and control of the EO-1 spacecraft to formation fly with the Landsat-7 spacecraft using an autonomous closed loop three axis navigation control, GPS, and Cross link navigation support. Simulation results using various fidelity levels of modeling, algorithms developed and implemented in MATLAB, and autonomous 'fuzzy logic' control using AutoCon will be presented. The results of these

  15. L4 Milestone Report for MixEOS 2016 experiments and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, Eric Nicholas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bradley, Paul Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Merritt, Elizabeth Catherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Guzik, Joyce Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Denne, Patrick Hagen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-01

    Accurate simulations of fluid and plasma flows require accurate thermodynamic properties of the fluids or plasmas. This thermodynamic information is represented by the equations of state of the materials. For pure materials, the equations of state may be represented by analytical models for idealized circumstances, or by tabular means, such as the Sesame tables. However, when a computational cell has a mixture of two or more fluids, the equations of state are not well understood, particularly under the circumstances of high energy densities. This is a particularly difficult issue for Eulerian codes, wherein mixed cells arise simply due to the advection process. LANL Eulerian codes typically assume an “Amagat’s Law” (or Law of Partial Volumes) for the mixture in which the pressures and temperatures of fluids are at an equilibrium that is consistent with the fluids being segregated within the cell. However, for purposes of computing other EOS properties, e.g., bulk modulus, or sound speed, the fluids are considered to be fully “mixed”. LANL has also been investigating implementing instead “Dalton’s Law” in which the total pressure is considered to be the sum of the partial pressures within the cell. For ideal gases, these two laws give the same result. Other possibilities are nonpressure- temperature-equilibrated approaches in which the two fluids are not assumed to “mix” at all, and the EOS properties of the cell are computed from, say, volume-weighted averages of the individual fluid properties. The assumption of the EOS properties within a mixed cell can have a pronounced effect on the behavior of the cell, resulting in, for example, different shock speeds, pressures, temperatures and densities within the cell. There is no apparent consensus as to which approach is best under HED conditions, though we note that under typical atmospheric and near atmospheric conditions the differences may be slight.

  16. Building A Collaborative And Distributed E&O Program For EarthScope

    Science.gov (United States)

    Hall-Wallace, M. K.; Boyd, T.; Richard, G.; Ellins, K.; Meertens, C.; Semken, S.; Taber, J.; Benthien, M.; Wald, L.; Marvinney, R.

    2003-12-01

    EarthScope's education and outreach (E&O) mission is to ensure that the EarthScope experiment creates as its legacy a public more knowledgeable and understanding of the scientific and societal contributions made by the EarthScope experiment and Earth science. It will fulfill this commitment by developing and disseminating programs and products that utilize the data, models, technology and discoveries of EarthScope. The EarthScope Education and Outreach Network (EON), consisting of local EON alliances, the EarthScope facilities, partner organizations and a coordinating office, will facilitate this E&O mission. The local EON alliances, which will vary in size and purpose to respond quickly and to meet the specific needs in a region, will carry out the bulk of the effort. Thus, EarthScope EON can provide customized services that engage culturally, economically and geographically diverse audiences at the national and local scales. The EarthScope facilities and research community will provide access to data, models, and visualization tools for educational purposes. Partnerships with other national and local science education and outreach programs at colleges, universities, research facilities and professional societies within the EarthScope community as well as relevant programs at museums and parks, state geologic surveys and emergency management agencies, and K-12 schools are critical to EON's success. These partnerships will allow EON to use existing resources, networks and expertise to gear up quickly and efficiently. As EON develops, it will reciprocate by contributing new resources and expertise to the partnerships that help improve public understanding of Earth systems overall and promote effective application of EarthScope discoveries. In this presentation, we will outline major programs and products envisioned for EarthScope, plans for evaluating those programs locally and nationally, and mechanisms for collaborating with existing E&O programs.

  17. The role of serial casting in early-onset scoliosis (EOS).

    Science.gov (United States)

    Baulesh, David M; Huh, Jeannie; Judkins, Timothy; Garg, Sumeet; Miller, Nancy H; Erickson, Mark A

    2012-01-01

    Serial casting has demonstrated efficacy for idiopathic early-onset scoliosis (EOS). Results of casting in nonidiopathic (syndromic and congenital) EOS patients have not previously been well described. A total of 53 patients underwent serial casting for EOS from 2005 to 2010 at a single institution. Deformity was classified as idiopathic or nonidiopathic. Diagnosis, time in cast, number of casts, use of bracing, complications, and outcomes were recorded. Radiographic measures included Cobb angle and thoracic height (T1-T12). Thoracic height velocity was calculated and compared with established norms. A total of 36 patients, 19 idiopathic and 17 nonidiopathic (14 syndromic, 3 congenital), completed cast treatment and had >6-month follow-up and were therefore included. Of those, 17% (6/36) experienced resolution of their deformity, 53% (19/26) are currently in braces, and 31% (11/36) had undergone surgery. Surgery occurred on average at age 5.6 years and was delayed by an average of 2.1 years from time of first cast. A 19% complication was observed. There was no statistical difference in the rate of resolution of deformity between idiopathic (5/19) and nonidiopathic (1/17) patients (P=0.182), although there exists a trend toward greater curve correction in idiopathic patients. Surgery occurred in fewer patients (2/19) in the idiopathic group compared with the nonidiopathic group (9/17) (P=0.006). Significant improvements in Cobb angle was observed in the idiopathic group (12.2 degrees) during casting (P=0.003). Nonidiopathic patients did not maintain the correction gained during casting at the time of final follow-up. T1-T12 height increased across all study patients regardless of etiology during the period of casting at similar velocity to established norms of 1.4 cm/y for this age group. Serial casting offers modest deformity correction in idiopathic deformities compared with nonidiopathic deformities. Thoracic height growth continued throughout the casting period

  18. The symmetry energy at suprasaturation density and the ASY-EOS experiment at GSI

    Directory of Open Access Journals (Sweden)

    De Filippo E.

    2017-01-01

    Full Text Available The ASY-EOS experiment at GSI laboratory measured the direct and elliptic flow of neutrons and light charged particles in the reaction 197Au+197 Au at 400 A MeV incident energy. The ratio of elliptic flow of neutrons with respect to that of the light charged particles was used as main experimental observable to probe the density dependence of the symmetry energy term of the nuclear equation of state. Results, obtained by comparison of the experimental data with the UrQMD model predictions, strongly support a moderately soft to linear density dependence of the symmetry energy at suprasaturation densities below 2ρ0.

  19. Relativistic nuclear collisions from the EOS experiment at the Bevalac: collective observables and multifragmentation

    International Nuclear Information System (INIS)

    Insolia, A.

    1996-01-01

    The EOS Collaborations has completed an exclusive study of relativistic heavy ion collisions at the Bevalac using a variety of projectile, target and beam energy combinations. We report here results on directed sidewards flow in Au+Au between 0.25 AGeV and 1.2 AGeV, using a standard in-plane transverse momentum analysis. We also report on projectile fragmentation of Au in C at 1 AGeV. An analysis of fluctuations and critical exponents for small systems seems to support the idea that the multifragmentation regime is associated with a liquid gas phase transition in nuclear matter. (authors)

  20. Evolution of the Earth Observing System (EOS) Data and Information System (EOSDIS)

    Science.gov (United States)

    Ramapriyan, Hampapuram K.; Behnke, Jeanne; Sofinowski, Edwin; Lowe, Dawn; Esfandiari, Mary Ann

    2008-01-01

    One of the strategic goals of the U.S. National Aeronautics and Space Administration (NASA) is to "Develop a balanced overall program of science, exploration, and aeronautics consistent with the redirection of the human spaceflight program to focus on exploration". An important sub-goal of this goal is to "Study Earth from space to advance scientific understanding and meet societal needs." NASA meets this subgoal in partnership with other U.S. agencies and international organizations through its Earth science program. A major component of NASA s Earth science program is the Earth Observing System (EOS). The EOS program was started in 1990 with the primary purpose of modeling global climate change. This program consists of a set of space-borne instruments, science teams, and a data system. The instruments are designed to obtain highly accurate, frequent and global measurements of geophysical properties of land, oceans and atmosphere. The science teams are responsible for designing the instruments as well as scientific algorithms to derive information from the instrument measurements. The data system, called the EOS Data and Information System (EOSDIS), produces data products using those algorithms as well as archives and distributes such products. The first of the EOS instruments were launched in November 1997 on the Japanese satellite called the Tropical Rainfall Measuring Mission (TRMM) and the last, on the U.S. satellite Aura, were launched in July 2004. The instrument science teams have been active since the inception of the program in 1990 and have participation from Brazil, Canada, France, Japan, Netherlands, United Kingdom and U.S. The development of EOSDIS was initiated in 1990, and this data system has been serving the user community since 1994. The purpose of this chapter is to discuss the history and evolution of EOSDIS since its beginnings to the present and indicate how it continues to evolve into the future. this chapter is organized as follows. Sect

  1. Eye trauma in boxing.

    Science.gov (United States)

    Corrales, Gustavo; Curreri, Anthony

    2009-10-01

    In boxing, along with a few other sports, trauma is inherent to the nature of the sport; therefore it is considered a high-risk sport for ocular injuries. The long-term morbidity of ocular injuries suffered by boxers is difficult to estimate due to the lack of structured long-term follow-up of these athletes. Complications of blunt ocular trauma may develop years after the athlete has retired from the ring and is no longer considered to be at risk for boxing-related injuries. This article describes the wide range of eye injuries a boxer can sustain, and their immediate and long-term clinical management.

  2. About the Eye

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI for Kids >> ...

  3. About the Eye

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI for Kids » ...

  4. About the Eye

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit ...

  5. About the Eye

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program ... To search for current job openings visit HHS USAJobs Home » NEI for ...

  6. The insurance industry and public-private collaborations as a vector to develop and spread EO technologies and techniques in the domain of Food Security: The Swiss Re case.

    Science.gov (United States)

    Coutu, S.; Ragaz, M.; Mäder, D.; Hammer, P.; Andriesse, M.; Güttinger, U.; Feyen, H.

    2017-12-01

    The insurance industry has been contributing to the resilient development of agriculture in multiple regions of the globe since the beginning of the 19th Century. It also has from the very beginning of the development of EO Sciences, kept a very close eye on the development of technologies and techniques in this domain. Recent advances in this area such as increased satellite imagery resolution, faster computation time and Big Data management combined with the ground-based knowledge from the insurance industry have offered farmers not only tools permitting better crop management, but also reliable and live yield coverage. This study presents several of these applications at different scales (industrial farming and micro-farming) and in different climate regions, with an emphasis on the limit of current products. Some of these limits such as lack of access of to ground data, R&D efforts or understanding of ground needs could be quickly overcome through closer public-private or private-private collaborations. However, despite a clear benefit for the Food Security nexus and potential win-win situations, those collaborations are not always simple to develop. We present here successful but also disappointing collaboration cases based on the Swiss Re experience, as a global insurance leader. As a conclusion, we highlight how academia, NGOs, governmental organization, start-ups and the insurance industry can get together to foster the development of EO in the domain of Food Security, and bring cutting-edge science to game changing industrial applications.

  7. Registration of clinical volumes to beams-eye-view images for real-time tracking

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.; Mishra, Pankaj; Berbeco, Ross I., E-mail: rberbeco@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

  8. On Biometrics With Eye Movements.

    Science.gov (United States)

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  9. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  10. Open Bibliography

    OpenAIRE

    Murray-Rust, Peter; Pollock, Rufus; MacGillivray, Mark; O'Steen, Ben; Waites, William

    2011-01-01

    Poster presented at the VSMF Symposium held at the Unilever Centre on 2011-01-17. More research is published currently than can be understood or followed by a researcher without the aid of a computer. We need Open shareable information on research publications, an Open Bibliography, to build the services that enable researchers to explore their field and discover the research they need. Producers of bibliographic data such as libraries, publishers, universities, scholars or social referenc...

  11. Open IS

    DEFF Research Database (Denmark)

    Germonprez, Matt; Crowston, Kevin; Avital, Michel

    2013-01-01

    The collective intelligence and collective action of “open” communities have produced a variety of complex knowledge goods and radical social change. The Information Systems (IS) community has invested significant effort into researching open communities and the ecosystems in which they operate...... therefore seeks to stimulate a thoughtful and dynamic discussion around the proposition that becoming a more open community will enhance the IS discipline’s scholarly inquiry and global impact....

  12. Gallbladder removal - open

    Science.gov (United States)

    Cholecystectomy - open; Gallbladder - open cholecystectomy; Cholecystitis - open cholecystectomy; Gallstones - open cholecystectomy ... a medical instrument called a laparoscope ( laparoscopic ... Open gallbladder surgery is used when laparoscopic surgery cannot ...

  13. Ultraviolet radiation: the eye

    International Nuclear Information System (INIS)

    Cesarini, J.P.; Sliney, D.H.

    1996-01-01

    Under most conditions, the eye is well adapted to protect itself against ultraviolet radiation encountered in the outdoor environment as a result of the exposure geometry of the sun. Only when snow is on the ground does one experience acute effects of UV sunlight exposure (i.e. snow blindness, or photokeratitis). With regard to artificial sources, there are many occasions where one views bright light sources such as tungsten-halogen lamps, arc lamps and welding arcs. Such viewing is normally only momentary because of the aversion response to bright light and due to discomfort glare. However, such an aversion does not take place for germicidal lamps and other UV lamps which do not contain a strong visible component in their spectrum. The adverse effects from viewing such sources has been studied for decades and during the last two decades guidelines for limiting exposure to protect the eye have been developed. The guidelines were fostered to a large extent by the growing use of lasers and the quickly recognized hazard posed by viewing laser sources. (author)

  14. Post-LASIK dry eye

    Science.gov (United States)

    Shtein, Roni M

    2011-01-01

    Laser-assisted in situ keratomileusis (LASIK) is a frequently performed corneal refractive surgery with excellent refractive outcomes. The most common complication of LASIK is dry eyes, with virtually all patients developing some degree of dryness in the immediate postoperative period. Identifying preoperative dry eyes, and conscientious attention and treatment in the perioperative time period, can lead to enhanced patient satisfaction and more accurate visual outcomes. Improved understanding of the development of dry eyes after LASIK will advance our understanding of the complex pathophysiology of dry eye disease. PMID:22174730

  15. Juvenile eye growth, when completed?

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Christensen, Anders S; Fledelius, Christian

    2014-01-01

    PURPOSE: To test Sorsby's classical statement of axial eye growth as completed at the age of 13 years, with a view also to differentiating between basic eye growth and juvenile elongation associated with eventual refractive change towards myopia. METHODS: (i) A total of 160 healthy eyes close...... about age 13 as general limit found support from the cross-sectional data, which suggested stable emmetropic eye size from about 11-12 years, with an average apparently outgrown male emmetropic value of 23.5 mm versus females' 22.9 mm. The longitudinal data, however, showed emmetropic growth also beyond...

  16. Land, Atmosphere Near Real-time Capability for EOS (LANCE) AMSR2 Data System

    Science.gov (United States)

    Smith, D. K.; Harrison, S.; Lin, H.; Flynn, S.; Nair, M.; Conover, H.; Graves, S. J.

    2016-12-01

    The Land, Atmosphere Near real-time Capability for EOS (LANCE) system was initiated to ensure the availability of NASA satellite data products to those partners who have grown to rely upon near real-time (NRT) data for their decision support systems. The LANCE Advanced Microwave Scanning Radiometer-EOS (AMSR-E) system was able to address the needs of the NRT community in areas such as weather prediction and forecasting, monitoring of natural hazards, disaster relief, agriculture, and homeland security for nearly one year before the instrument failed in 2011. The timely launch of Global Change Observation Mission -Water 1 (GCOM-W1) and the AMSR2 instrument by the Japanese Aerospace Exploration Agency (JAXA) in 2012 was very important to continue the time series of AMSR instruments. The LANCE element for AMSR2 was able to leverage the LANCE AMSR-E system architecture, using modified AMSR-E standard product algorithms in order to make preliminary data products available to NRT users before US AMSR2 standard product algorithms were available. This presentation will describe the five AMSR2 NRT product suites available from LANCE - Sea Ice, Snow, Rain/Ocean, and Soil Moisture. We will also discuss future plans for LANCE AMSR2.

  17. Femoral anteversion assessment: Comparison of physical examination, gait analysis, and EOS biplanar radiography.

    Science.gov (United States)

    Westberry, David E; Wack, Linda I; Davis, Roy B; Hardin, James W

    2018-05-01

    Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Cross calibration of the Landsat-7 ETM+ and EO-1 ALI sensor

    Science.gov (United States)

    Chander, G.; Meyer, D.J.; Helder, D.L.

    2004-01-01

    As part of the Earth Observer 1 (EO-1) Mission, the Advanced Land Imager (ALI) demonstrates a potential technological direction for Landsat Data Continuity Missions. To evaluate ALI's capabilities in this role, a cross-calibration methodology has been developed using image pairs from the Landsat-7 (L7) Enhanced Thematic Mapper Plus (ETM+) and EO-1 (ALI) to verify the radiometric calibration of ALI with respect to the well-calibrated L7 ETM+ sensor. Results have been obtained using two different approaches. The first approach involves calibration of nearly simultaneous surface observations based on image statistics from areas observed simultaneously by the two sensors. The second approach uses vicarious calibration techniques to compare the predicted top-of-atmosphere radiance derived from ground reference data collected during the overpass to the measured radiance obtained from the sensor. The results indicate that the relative sensor chip assemblies gains agree with the ETM+ visible and near-infrared bands to within 2% and the shortwave infrared bands to within 4%.

  19. Expanding NASA's Land, Atmosphere Near real-time Capability for EOS

    Science.gov (United States)

    Davies, D.; Michael, K.; Masuoka, E.; Ye, G.; Schmaltz, J. E.; Harrison, S.; Ziskin, D.; Durbin, P. B.; Protack, S.; Rinsland, P. L.; Slayback, D. A.; Policelli, F. S.; Olsina, O.; Fu, G.; Ederer, G. A.; Ding, F.; Braun, J.; Gumley, L.; Prins, E. M.; Davidson, C. C.; Wong, M. M.

    2017-12-01

    NASA's Land, Atmosphere Near real-time Capability for EOS (LANCE) is a virtual system that provides near real-time EOS data and imagery to meet the needs of scientists and application users interested in monitoring a wide variety of natural and man-made phenomena in near real-time. Over the last year: near real-time products and imagery from MOPITT, MISR, OMPS and VIIRS (Land and Atmosphere) have been added; the Fire Information for Resource Management System (FIRMS) has been updated and LANCE has begun the process of integrating the Global NRT flood product. In addition, following the AMSU-A2 instrument anomaly in September 2016, AIRS-only products have replaced the NRT level 2 AIRS+AMSU products. This presentation provides a brief overview of LANCE, describes the new products that are recently available and contains a preview of what to expect in LANCE over the coming year. For more information visit: https://earthdata.nasa.gov/lance

  20. On-orbit test results from the EO-1 Advanced Land Imager

    Science.gov (United States)

    Evans, Jenifer B.; Digenis, Constantine J.; Gibbs, Margaret D.; Hearn, David R.; Lencioni, Donald E.; Mendenhall, Jeffrey A.; Welsh, Ralph D.

    2002-01-01

    The Advanced Land Imager (ALI) is the primary instrument flown on the first Earth Observing mission (EO-1), launched on November 21, 2000. It was developed under NASA's New Millennium Program (NMP). The NMP mission objective is to flight-validate advanced technologies that will enable dramatic improvements in performance, cost, mass, and schedule for future, Landsat-like, Earth Science Enterprise instruments. ALI contains a number of innovative features designed to achieve this objective. These include the basic instrument architecture which employs a push-broom data collection mode, a wide field of view optical design, compact multi-spectral detector arrays, non-cryogenic HgCdTe for the short wave infrared bands, silicon carbide optics, and a multi-level solar calibration technique. During the first ninety days on orbit, the instrument performance was evaluated by collecting several Earth scenes and comparing them to identical scenes obtained by Landsat7. In addition, various on-orbit calibration techniques were exercised. This paper will present an overview of the EO-1 mission activities during the first ninety days on-orbit, details of the ALI instrument performance and a comparison with the ground calibration measurements.