WorldWideScience

Sample records for eyes closed ec

  1. Directionality of large-scale resting-state brain networks during eyes open and eyes closed conditions

    NARCIS (Netherlands)

    Zhang, Delong; Liang, Bishan; Wu, Xia; Wang, Zengjian; Xu, Pengfei; Chang, Song; Liu, Bo; Liu, Ming; Huang, Ruiwang

    2015-01-01

    The present study examined directional connections in the brain among resting-state networks (RSNs) when the participant had their eyes open (E0) or had their eyes closed (EC). The resting state fMRI data were collected from 20 healthy participants (9 males, 20.17 +/- 2.74 years) under the EO and EC

  2. Frequency-Dependent Modulation of Regional Synchrony in the Human Brain by Eyes Open and Eyes Closed Resting-States.

    Science.gov (United States)

    Song, Xiaopeng; Zhou, Shuqin; Zhang, Yi; Liu, Yijun; Zhu, Huaiqiu; Gao, Jia-Hong

    2015-01-01

    The eyes-open (EO) and eyes-closed (EC) states have differential effects on BOLD-fMRI signal dynamics, affecting both the BOLD oscillation frequency of a single voxel and the regional homogeneity (ReHo) of several neighboring voxels. To explore how the two resting-states modulate the local synchrony through different frequency bands, we decomposed the time series of each voxel into several components that fell into distinct frequency bands. The ReHo in each of the bands was calculated and compared between the EO and EC conditions. The cross-voxel correlations between the mean frequency and the overall ReHo of each voxel's original BOLD series in different brain areas were also calculated and compared between the two states. Compared with the EC state, ReHo decreased with EO in a wide frequency band of 0.01-0.25 Hz in the bilateral thalamus, sensorimotor network, and superior temporal gyrus, while ReHo increased significantly in the band of 0-0.01 Hz in the primary visual cortex, and in a higher frequency band of 0.02-0.1 Hz in the higher order visual areas. The cross-voxel correlations between the frequency and overall ReHo were negative in all the brain areas but varied from region to region. These correlations were stronger with EO in the visual network and the default mode network. Our results suggested that different frequency bands of ReHo showed different sensitivity to the modulation of EO-EC states. The better spatial consistency between the frequency and overall ReHo maps indicated that the brain might adopt a stricter frequency-dependent configuration with EO than with EC.

  3. Brain spontaneous fluctuations in sensorimotor regions were directly related to eyes open and eyes closed: evidences from a machine learning approach

    Directory of Open Access Journals (Sweden)

    Bishan eLiang

    2014-08-01

    Full Text Available Previous studies have demonstrated that the difference between resting-state brain activations depends on whether the subject was eyes open (EO or eyes closed (EC. However, whether the spontaneous fluctuations are directly related to these two different resting states are still largely unclear. In the present study, we acquired resting-state functional magnetic resonance imaging data from 24 healthy subjects (11 males, 20.17 ± 2.74 years under the EO and EC states. The amplitude of the spontaneous brain activity in low-frequency band was subsequently investigated by using the metric of fractional amplitude of low frequency fluctuation (fALFF for each subject under each state. A support vector machine (SVM analysis was then applied to evaluate whether the category of resting states could be determined from the brain spontaneous fluctuations. We demonstrated that these two resting states could be decoded from the identified pattern of brain spontaneous fluctuations, predominantly based on fALFF in the sensorimotor module. Specifically, we observed prominent relationships between increased fALFF for EC and decreased fALFF for EO in sensorimotor regions. Overall, the present results indicate that a SVM performs well in the discrimination between the brain spontaneous fluctuations of distinct resting states and provide new insight into the neural substrate of the resting states during EC and EO.

  4. Eyes wide shut: amygdala mediates eyes-closed effect on emotional experience with music.

    Science.gov (United States)

    Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma

    2009-07-15

    The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, 'low', visceral-, and 'high', cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. 'low') and cognitive (i.e. 'high') related processes of emotions.

  5. Evaluation of Occupational Closed Globe Eye Injuries

    Directory of Open Access Journals (Sweden)

    Berna Akova-Budak

    2016-01-01

    Full Text Available Aim: To evaluate closed glob injuries related to occupational accidents of patients who had official occupational accident records. Material and Method: The medical records of patients with ocular injuries who referred to Department of Ophthalmology or emergency of Uludag University, School of Medicine between January 2010 and December 2013 with official occupational accident report were retrospectively reviewed. The patients with closed globe injuries following trauma were included. Age, sex, the injured eye, the cause of the trauma, whether the precautions were taken or not by the patient, the damage due to trauma were recorded. Results: According to the official records, 108 patients referred to our clinic with closed globe injury related to occupational accident. One hundred twenty eyes of 108 patients ( 2 females, 106 males were evaluated. The mean age of the patients was 33±8.6 years. The most frequent cause of injury was foreign bodies on the ocular surface followed by blunt trauma. The mean age of the patients injured with foreign bodies was found to be significantly lower than the patients injured with blunt objects (p=0.039. Thirteen patients reported that they had used preventive equipment. Discussion: It is of utmost importance that the awareness of the workers should be raised and they should be educated about the use of preventive equipment to prevent the occupational eye injuries. The education of particularly the younger patients about the occupational injuries when they begin to work may decrease the rate of occupational accident related eye injuries.

  6. Closed-eye orbital prosthesis: a clinical report.

    Science.gov (United States)

    Hatamleh, Muhanad M; Watson, Jason; Srinivasan, Dilip

    2015-03-01

    One of the most challenging prostheses to fabricate is an acceptable orbital prosthesis. Successful reconstruction of the complex missing tissues, the globe, muscle, skin, and bony elements requires time and high levels of practical skill. A good match to the contralateral nondefect side will help mask the underlying defect and give the patient confidence to return to normal, routine life. The contralateral eye opening will commonly dictate the eye opening of such a prosthesis, but because of the expressive nature of the eye and its high levels of mobility, this can be difficult to achieve. This clinical report presents a patient who had an extended orbital exenteration and right maxillectomy to remove a maxillary squamous cell carcinoma. An alternative approach to constructing an orbital prosthesis was undertaken with the eye closed. Compared to the normal method of fabrication, this process was less complex and quicker, made the prosthesis less "staring," camouflaged the defect, and reduced the detection of the prosthesis because of movements in the remaining eye. The patient engaged in his routine daily life, which reinforced his self-esteem, confidence, and reintegration into the community. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Normative values for the unipedal stance test with eyes open and closed.

    Science.gov (United States)

    Springer, Barbara A; Marin, Raul; Cyhan, Tamara; Roberts, Holly; Gill, Norman W

    2007-01-01

    Limited normative data are available for the unipedal stance test (UPST), making it difficult for clinicians to use it confidently to detect subtle balance impairments. The purpose of this study was to generate normative values for repeated trials of the UPST with eyes opened and eyes closed across age groups and gender. This prospective, mixed-model design was set in a tertiary care medical center. Healthy subjects (n= 549), 18 years or older, performed the UPST with eyes open and closed. Mean and best of 3 UPST times for males and females of 6 age groups (18-39, 40-49, 50-59, 60-69, 70-79, and 80+) were documented and inter-rater reliability was tested. There was a significant age dependent decrease in UPST time during both conditions. Inter-rater reliability for the best of 3 trials was determined to be excellent with an intra-class correlation coefficient of 0.994 (95% confidence interval 0.989-0.996) for eyes open and 0.998 (95% confidence interval 0.996-0.999) for eyes closed. This study adds to the understanding of typical performance on the UPST. Performance is age-specific and not related to gender. Clinicians now have more extensive normative values to which individuals can be compared.

  8. A Study of Deep CNN-Based Classification of Open and Closed Eyes Using a Visible Light Camera Sensor

    Directory of Open Access Journals (Sweden)

    Ki Wan Kim

    2017-06-01

    Full Text Available The necessity for the classification of open and closed eyes is increasing in various fields, including analysis of eye fatigue in 3D TVs, analysis of the psychological states of test subjects, and eye status tracking-based driver drowsiness detection. Previous studies have used various methods to distinguish between open and closed eyes, such as classifiers based on the features obtained from image binarization, edge operators, or texture analysis. However, when it comes to eye images with different lighting conditions and resolutions, it can be difficult to find an optimal threshold for image binarization or optimal filters for edge and texture extraction. In order to address this issue, we propose a method to classify open and closed eye images with different conditions, acquired by a visible light camera, using a deep residual convolutional neural network. After conducting performance analysis on both self-collected and open databases, we have determined that the classification accuracy of the proposed method is superior to that of existing methods.

  9. LSD alters eyes-closed functional connectivity within the early visual cortex in a retinotopic fashion.

    Science.gov (United States)

    Roseman, Leor; Sereno, Martin I; Leech, Robert; Kaelen, Mendel; Orban, Csaba; McGonigle, John; Feilding, Amanda; Nutt, David J; Carhart-Harris, Robin L

    2016-08-01

    The question of how spatially organized activity in the visual cortex behaves during eyes-closed, lysergic acid diethylamide (LSD)-induced "psychedelic imagery" (e.g., visions of geometric patterns and more complex phenomena) has never been empirically addressed, although it has been proposed that under psychedelics, with eyes-closed, the brain may function "as if" there is visual input when there is none. In this work, resting-state functional connectivity (RSFC) data was analyzed from 10 healthy subjects under the influence of LSD and, separately, placebo. It was suspected that eyes-closed psychedelic imagery might involve transient local retinotopic activation, of the sort typically associated with visual stimulation. To test this, it was hypothesized that, under LSD, patches of the visual cortex with congruent retinotopic representations would show greater RSFC than incongruent patches. Using a retinotopic localizer performed during a nondrug baseline condition, nonadjacent patches of V1 and V3 that represent the vertical or the horizontal meridians of the visual field were identified. Subsequently, RSFC between V1 and V3 was measured with respect to these a priori identified patches. Consistent with our prior hypothesis, the difference between RSFC of patches with congruent retinotopic specificity (horizontal-horizontal and vertical-vertical) and those with incongruent specificity (horizontal-vertical and vertical-horizontal) increased significantly under LSD relative to placebo, suggesting that activity within the visual cortex becomes more dependent on its intrinsic retinotopic organization in the drug condition. This result may indicate that under LSD, with eyes-closed, the early visual system behaves as if it were seeing spatially localized visual inputs. Hum Brain Mapp 37:3031-3040, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Eyes-Closed Single-Limb Balance is Not Related to Hypermobility Status in Dancers.

    Science.gov (United States)

    Marulli, Tiffany A; Harmon-Matthews, Lindsay E; Davis-Coen, J Hope; Willigenburg, Nienke W; Hewett, Timothy E

    2017-06-15

    Hypermobility may be associated with decreased lower extremity proprioception, which in turn may increase injury risk. The prevalence of hypermobility in dancers varies across studies, but joint hypermobility appears to be more common in dancers than in the general population. The purpose of this study was to determine how hypermobility affects eyes-closed single-limb balance as an indirect measure of proprioception in dancers. The secondary aim was to compare hypermobility and balance across dancer affiliation groups. Data were collected from 45 professional dancers, 11 collegiate modern dancers, 227 student dancers, and 15 pre-professional dancers during routine dance screens. Dancer hypermobility status was assessed via an eight-point Beighton-Horan Laxity test. Single-limb balance time, in seconds, was assessed in parallel position with the eyes closed. Hypermobile (HM) and non-hypermobile (NHM) dancers showed very similar balance times (HM median: 36.5 seconds; NHM median: 33.0 seconds; p = 0.982). Hypermobility was not significantly different between dancer affiliation groups (p = 0.154): 47% in ballet academy students, 27% in collegiate modern dancers, 62% in pre-professional dancers, and 36% in professional dancers. The student, pre-professional, and professional ballet dancers all demonstrated longer balance times than the collegiate modern dancers; however, this difference was only significant between the professional ballet dancers and collegiate modern dancers (p = 0.026). Dancers demonstrated a higher prevalence of hypermobility than what has been reported for the general population. Joint hypermobility did not affect eyes-closed single-limb balance time. Future studies are needed to determine if joint hypermobility affects more sensitive measures of proprioception and risk of injury.

  11. Eye-hand coupling during closed-loop drawing: evidence of shared motor planning?

    Science.gov (United States)

    Reina, G Anthony; Schwartz, Andrew B

    2003-04-01

    Previous paradigms have used reaching movements to study coupling of eye-hand kinematics. In the present study, we investigated eye-hand kinematics as curved trajectories were drawn at normal speeds. Eye and hand movements were tracked as a monkey traced ellipses and circles with the hand in free space while viewing the hand's position on a computer monitor. The results demonstrate that the movement of the hand was smooth and obeyed the 2/3 power law. Eye position, however, was restricted to 2-3 clusters along the hand's trajectory and fixed approximately 80% of the time in one of these clusters. The eye remained stationary as the hand moved away from the fixation for up to 200 ms and saccaded ahead of the hand position to the next fixation along the trajectory. The movement from one fixation cluster to another consistently occurred just after the tangential hand velocity had reached a local minimum, but before the next segment of the hand's trajectory began. The next fixation point was close to an area of high curvature along the hand's trajectory even though the hand had not reached that point along the path. A visuo-motor illusion of hand movement demonstrated that the eye movement was influenced by hand movement and not simply by visual input. During the task, neural activity of pre-motor cortex (area F4) was recorded using extracellular electrodes and used to construct a population vector of the hand's trajectory. The results suggest that the saccade onset is correlated in time with maximum curvature in the population vector trajectory for the hand movement. We hypothesize that eye and arm movements may have common, or shared, information in forming their motor plans.

  12. Low luminance/eyes closed and monochromatic stimulations reduce variability of flash visual evoked potential latency

    Directory of Open Access Journals (Sweden)

    Senthil Kumar Subramanian

    2013-01-01

    Full Text Available Context: Visual evoked potentials are useful in investigating the physiology and pathophysiology of the human visual system. Flash visual evoked potential (FVEP, though technically easier, has less clinical utility because it shows great variations in both latency and amplitude for normal subjects. Aim: To study the effect of eye closure, low luminance, and monochromatic stimulation on the variability of FVEPs. Subjects and Methods: Subjects in self-reported good health in the age group of 18-30 years were divided into three groups. All participants underwent FVEP recording with eyes open and with white light at 0.6 J luminance (standard technique. Next recording was done in group 1 with closed eyes, group 2 with 1.2 and 20 J luminance, and group 3 with red and blue lights, while keeping all the other parameters constant. Two trials were given for each eye, for each technique. The same procedure was repeated at the same clock time on the following day. Statistical Analysis: Variation in FVEP latencies between the individuals (interindividual variability and the variations within the same individual for four trials (intraindividual variability were assessed using coefficient of variance (COV. The technique with lower COV was considered the better method. Results: Recording done with closed eyes, 0.6 J luminance, and monochromatic light (blue > red showed lower interindividual and intraindividual variability in P2 and N2 as compared to standard techniques. Conclusions: Low luminance flash stimulations and monochromatic light will reduce FVEP latency variability and may be clinically useful modifications of FVEP recording technique.

  13. Effect of Low-Level Laser Stimulation on EEG Power in Normal Subjects with Closed Eyes

    Directory of Open Access Journals (Sweden)

    Jih-Huah Wu

    2013-01-01

    Full Text Available In a previous study, we found that the low-level laser (LLL stimulation at the palm with a frequency of 10 Hz was able to induce significant brain activation in normal subjects with opened eyes. However, the electroencephalography (EEG changes to LLL stimulation in subjects with closed eyes have not been studied. In the present study, the laser array stimulator was applied to deliver insensible laser stimulations to the palm of the tested subjects with closed eyes (the laser group. The EEG activities before, during, and after the laser stimulation were collected. The EEG amplitude powers of each EEG frequency band at 19 locations were calculated. These power data were then analyzed by SPSS software using repeated-measure ANOVAs and appropriate posthoc tests. We found a pronounced decrease in the EEG power in alpha-bandwidth during laser simulation and then less decrease in the EEG power in delta-bandwidth in normal subjects with laser stimulation. The EEG power in beta-bandwidth in the right occipital area also decreased significantly in the laser group. We suggest that LLL stimulation might be conducive to falling into sleep in patients with sleep problems.

  14. Nuclear power plant performance in the EC in 1978

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    According to the report presented by the Statistical Office of the Ec, nuclear electricity generation in the nine EC countries has been increased in 1978 by 11% to a net value of 115 TWh as compared to the year before. Installed capacity went up by 18.6% to a net value of 24. 000 MWe at the end of the year. The mean availability period has been close to the hitherto best value of 6000 h/a. The share of nuclear energy in total electricity generation in the EC rose by 0.5% to 10.5%. (orig.) [de

  15. Effects of treadmill training with the eyes closed on gait and balance ability of chronic stroke patients.

    Science.gov (United States)

    Kim, Yong-Wook; Moon, Sung-Jun

    2015-09-01

    [Purpose] The purpose of this study was to compare the effect of treadmill walking with the eyes closed and open on the gait and balance abilities of chronic stroke patients. [Subjects and Methods] Thirty patients with chronic stroke participated in this study. The treadmill gait training for each group lasted 40 minutes, and sessions were held 3 times a week for 4 weeks. Gait ability was measured using a Biodex Gait Trainer Treadmill System. Balance ability was measured using a Biodex Balance System. [Results] After the treadmill training' the treadmill training with eyes closed (TEC) group showed significant improvements in walking distance' step length' coefficient of variation' and limit of stability (overall' lateral affected' forward lateral unaffected) compared to the treadmill training with eyes open (TEO) group. [Conclusion] The walking and balance abilities of the TEC participants showed more improvement after the treadmill walking sessions than those of the TEO participants. Therefore' treadmill walking with visual deprivation may be useful for the rehabilitation of patients with chronic stroke.

  16. Stepping in Place While Voluntarily Turning Around Produces a Long-Lasting Posteffect Consisting in Inadvertent Turning While Stepping Eyes Closed

    Directory of Open Access Journals (Sweden)

    Stefania Sozzi

    2016-01-01

    Full Text Available Training subjects to step in place on a rotating platform while maintaining a fixed body orientation in space produces a posteffect consisting in inadvertent turning around while stepping in place eyes closed (podokinetic after-rotation, PKAR. We tested the hypothesis that voluntary turning around while stepping in place also produces a posteffect similar to PKAR. Sixteen subjects performed 12 min of voluntary turning while stepping around their vertical axis eyes closed and 12 min of stepping in place eyes open on the center of a platform rotating at 60°/s (pretests. Then, subjects continued stepping in place eyes closed for at least 10 min (posteffect. We recorded the positions of markers fixed to head, shoulder, and feet. The posteffect of voluntary turning shared all features of PKAR. Time decay of angular velocity, stepping cadence, head acceleration, and ratio of angular velocity after to angular velocity before were similar between both protocols. Both postrotations took place inadvertently. The posteffects are possibly dependent on the repeated voluntary contraction of leg and foot intrarotating pelvic muscles that rotate the trunk over the stance foot, a synergy common to both protocols. We propose that stepping in place and voluntary turning can be a scheme ancillary to the rotating platform for training body segment coordination in patients with impairment of turning synergies of various origin.

  17. Aladdin Sane and Close-Up Eye Asymmetry: David Bowie’s Contribution to Comic Book Visual Language

    Directory of Open Access Journals (Sweden)

    Igor Juricevic

    2017-03-01

    Full Text Available In April 1973 David Bowie released 'Aladdin Sane'. The cover of 'Aladdin Sane' features an iconic image of David Bowie, a close-up shot of the artist with brightly colored orange hair and asymmetrical lightning bolt make-up on the right side of his face. This article argues that the cover image for 'Aladdin Sane' uses the Close-Up Eye Asymmetry (CUE-A pictorial device (i.e., close-up view of David Bowie, asymmetrical make-up around his eye and that CUE-A was adopted into Comic Book Visual Language by first providing evidence that CUE-A is used in comic book art. A link is then established between comic book art and music album art by showing that: (1 David Bowie was familiar with Comic Book Visual Language and could make a contribution to the language, and (2 comic book artists are influenced by music album art. I then make a case that the adoption of CUE-A into Comic Book Visual Language was specifically due to the cover image for 'Aladdin Sane' by analyzing: (1 the use of CUE-A by influential artists in the 1990s and (2 the different rates of adoption of CUE-A for the depiction of established versus newer comic book characters.

  18. Effects of Sludge Compost on EC value of Saline Soil and Plant Height of Medicago

    Science.gov (United States)

    Sun, Chongyang; Zhao, Ke; Chen, Xing; Wang, Xiaohui

    2017-12-01

    In this study, the effects of sludge composting on the EC value of saline soil and the response to Medicago plant height were studied by planting Medicago with pots for 45 days in different proportions as sludge composting with saline soil. The results showed that the EC value of saline soil did not change obviously with the increase of fertilization ratio,which indicated that the EC value of saline soil was close to that of the original soil. The EC decreased by 31.45% at fertilization ratio of 40%. The height of Medicago reached the highest at 40% fertilization ratio, and that was close to 60% fertilization ratio, and the difference was significant with other treatments. By comprehensive analyse and compare,the optimum application rate of sludge compost was 40% under this test condition.

  19. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  20. 77 FR 63845 - National Eye Institute; Notice of Closed Meetings

    Science.gov (United States)

    2012-10-17

    ... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI-RFA Stem Cell... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300... Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300...

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Dry Eye Symptoms Related Ask an Ophthalmologist Answers Can a six-month dissolvable punctal plug be removed ... my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes ...

  2. EC-fans and fan control systems; EC-ventilatoren en ventilatorregelsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Havenaar, D.

    2011-07-15

    Saving of energy can be achieved by the design and application of energy efficient components such as EC-fans (EC stands for Electronically Commutated technology), which are used in different types of cooling-refrigeration and air conditioning systems. In this article attention is paid to two products of Ziehl-Abigg: the Icontrol and the Fcontrol frequency converters. [Dutch] Het beperken van het energiegebruik en het verminderen van de uitstoot van het broeikasgas CO2 is voor de sector een belangrijke opgave. Door het ontwerpen en toepassen van energie-efficiente componenten zoals EC-ventilatoren (EC staat voor Electronically Commutated technologie) in allerlei koel-, vries- en luchtbehandelingsinstallaties kan veel bespaard worden in het energiegebruik. In dit artikel wordt aandacht besteed aan 2 producten van Ziehl-Abigg: de Icontrol en de Fcontrol frequentie omvormers.

  3. LASIK Eye Surgery

    Science.gov (United States)

    ... at the front of your eye — to improve vision. Normally, images are clearly focused on the retina in the back of your eye because the ... sharply, light rays focus in front of the retina and blur distant vision. You can see objects that are close fairly ...

  4. SABRE: A Sensitive Attribute Bucketization and REdistribution framework for t-closeness

    KAUST Repository

    Cao, Jianneng

    2010-05-19

    Today, the publication of microdata poses a privacy threat: anonymous personal records can be re-identified using third data sources. Past research has tried to develop a concept of privacy guarantee that an anonymized data set should satisfy before publication, culminating in the notion of t-closeness. To satisfy t-closeness, the records in a data set need to be grouped into Equivalence Classes (ECs), such that each EC contains records of indistinguishable quasi-identifier values, and its local distribution of sensitive attribute (SA) values conforms to the global table distribution of SA values. However, despite this progress, previous research has not offered an anonymization algorithm tailored for t-closeness. In this paper, we cover this gap with SABRE, a SA Bucketization and REdistribution framework for t-closeness. SABRE first greedily partitions a table into buckets of similar SA values and then redistributes the tuples of each bucket into dynamically determined ECs. This approach is facilitated by a property of the Earth Mover\\'s Distance (EMD) that we employ as a measure of distribution closeness: If the tuples in an EC are picked proportionally to the sizes of the buckets they hail from, then the EMD of that EC is tightly upper-bounded using localized upper bounds derived for each bucket. We prove that if the t-closeness constraint is properly obeyed during partitioning, then it is obeyed by the derived ECs too. We develop two instantiations of SABRE and extend it to a streaming environment. Our extensive experimental evaluation demonstrates that SABRE achieves information quality superior to schemes that merely applied algorithms tailored for other models to t-closeness, and can be much faster as well. © 2010 Springer-Verlag.

  5. Glaucoma in Patients with Eyes Close to Areas Affected by Port-wine Stain has Lateral and Gender Predilection

    Directory of Open Access Journals (Sweden)

    Yue Wu

    2017-01-01

    Conclusions: High glaucoma incidence was observed in patients with eyes close to PWS. More attention should be paid to glaucoma screening for right lateral and bilateral PWS patients. The predominance of males in Sturge–Weber syndrome (SWS early-onset glaucoma patients might be due to the limitation of the case number; however, it might also provide us a new clue of potential relationship between SWS and PCG.

  6. Embedding visual routines in AnaFocus' Eye-RIS Vision Systems for closing the perception to action loop in roving robots

    Science.gov (United States)

    Jiménez-Marrufo, A.; Caballero-García, D. J.

    2011-05-01

    The purpose of the current paper is to describe how different visual routines can be developed and embedded in the AnaFocus' Eye-RIS Vision System on Chip (VSoC) to close the perception to action loop within the roving robots developed under the framework of SPARK II European project. The Eye-RIS Vision System on Chip employs a bio-inspired architecture where image acquisition and processing are truly intermingled and the processing itself is carried out in two steps. At the first step, processing is fully parallel owing to the concourse of dedicated circuit structures which are integrated close to the sensors. At the second step, processing is realized on digitally-coded information data by means of digital processors. All these capabilities make the Eye-RIS VSoC very suitable for the integration within small robots in general, and within the robots developed by the SPARK II project in particular. These systems provide with image-processing capabilities and speed comparable to high-end conventional vision systems without the need for high-density image memory and intensive digital processing. As far as perception is concerned, current perceptual schemes are often based on information derived from visual routines. Since real world images are quite complex to be processed for perceptual needs with traditional approaches, more computationally feasible algorithms are required to extract the desired features from the scene in real time, to efficiently proceed with the consequent action. In this paper the development of such algorithms and their implementation taking full advantage of the sensing-processing capabilities of the Eye-RIS VSoC are described.

  7. The EC TACIS project 'Social impact of closing Chornobyl NPP' objectives, tasks and intended outcomes

    International Nuclear Information System (INIS)

    Schoen, A.

    2001-01-01

    Being part of the common activities of Slavutich and ChNPP, our EC TACIS project representatives already actively participated in the elaboration of the state programme aimed to ensure the social security of the ChNPP personnel and the population of Slavutich in the result of the final shut down of ChNPP

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... bloodshot when I wake up? Jun 26, 2016 Why are my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes when I sleep? Feb 10, 2016 Can light sensitivity from Parkinson’s ...

  9. EcPV2 DNA in equine genital squamous cell carcinomas and normal genital mucosa.

    Science.gov (United States)

    Bogaert, Lies; Willemsen, Anouk; Vanderstraeten, Eva; Bracho, Maria A; De Baere, Cindy; Bravo, Ignacio G; Martens, Ann

    2012-07-06

    Squamous cell carcinoma (SCC) represents the most common genital malignant tumor in horses. Similar to humans, papillomaviruses (PVs) have been proposed as etiological agents and recently Equine papillomavirus type 2 (EcPV2) has been identified in a subset of genital SCCs. The goals of this study were (1) to determine the prevalence of EcPV2 DNA in tissue samples from equine genital SCCs, penile intraepithelial neoplasia (PIN) and penile papillomas, using EcPV2-specific PCR, (2) to examine the prevalence of latent EcPV2 infection in healthy genital mucosa and (3) to determine genetic variability within EcPV2 and to disentangle phylogenetic relationships of EcPV2 among PVs. EcPV2 DNA was detected in all but one penile SCC (15/16), in all PIN lesions (8/8) and penile papillomas (4/4). Additionally, EcPV2 DNA was demonstrated in one of two metastasized lymph nodes, one contact metastasis in the mouth, two vaginal and one anal lesion. In healthy horses, EcPV2 DNA was detected in 10% (4/39) of penile swabs but in none of vulvovaginal swabs (0/20). This study confirms the presence of EcPV2 DNA in equine genital SCCs and shows its involvement in anal lesions, a lymph node and contact metastases. Latent EcPV2 presence was also shown in normal male genital mucosa. We found that different EcPV2 variants cocirculate among horses and that EcPV2 is related to the Delta+Zeta PVs and is only a very distant relative of high-risk human PVs causing genital cancer. Thus, similar viral tropism and similar malignant outcome of the infection do not imply close evolutionary relationship. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Rapid procedure to calibrate EC-10 and EC-20 capacitance sensors ...

    African Journals Online (AJOL)

    A rapid calibration procedure for EC-10 and EC-20 sensors is introduced to promote the commercial use of these sensors for hydroponic irrigation management in coir. The method is comprised of taking one sensor reading, by a sensor installed under hydroponic crop production conditions, and one gravimetric sample, ...

  11. Determination of primary combustion source organic carbon-to-elemental carbon (OC / EC ratio using ambient OC and EC measurements: secondary OC-EC correlation minimization method

    Directory of Open Access Journals (Sweden)

    C. Wu

    2016-05-01

    Full Text Available Elemental carbon (EC has been widely used as a tracer to track the portion of co-emitted primary organic carbon (OC and, by extension, to estimate secondary OC (SOC from ambient observations of EC and OC. Key to this EC tracer method is to determine an appropriate OC / EC ratio that represents primary combustion emission sources (i.e., (OC / ECpri at the observation site. The conventional approaches include regressing OC against EC within a fixed percentile of the lowest (OC / EC ratio data (usually 5–20 % or relying on a subset of sampling days with low photochemical activity and dominated by local emissions. The drawback of these approaches is rooted in its empirical nature, i.e., a lack of clear quantitative criteria in the selection of data subsets for the (OC / ECpri determination. We examine here a method that derives (OC / ECpri through calculating a hypothetical set of (OC / ECpri and SOC followed by seeking the minimum of the coefficient of correlation (R2 between SOC and EC. The hypothetical (OC / ECpri that generates the minimum R2(SOC,EC then represents the actual (OC / ECpri ratio if variations of EC and SOC are independent and (OC / ECpri is relatively constant in the study period. This Minimum R Squared (MRS method has a clear quantitative criterion for the (OC / ECpri calculation. This work uses numerically simulated data to evaluate the accuracy of SOC estimation by the MRS method and to compare with two commonly used methods: minimum OC / EC (OC / ECmin and OC / EC percentile (OC / EC10 %. Log-normally distributed EC and OC concentrations with known proportion of SOC are numerically produced through a pseudorandom number generator. Three scenarios are considered, including a single primary source, two independent primary sources, and two correlated primary sources. The MRS method consistently yields the most accurate SOC estimation. Unbiased SOC estimation by OC

  12. Equity and Blindness: Closing Evidence Gaps to Support Universal Eye Health.

    Science.gov (United States)

    Ramke, Jacqueline; Zwi, Anthony B; Palagyi, Anna; Blignault, Ilse; Gilbert, Clare E

    2015-01-01

    The World Health Organization Program for the Prevention of Blindness adopted the principles of universal health coverage (UHC) in its latest plan, Universal Eye Health: A Global Action Plan, 2014-2019. This plan builds on the achievements of Vision 2020, which aimed to reduce the global prevalence of avoidable blindness, and its unequal distribution, by the year 2020. We reviewed the literature on health equity and the generation and use of evidence to promote equity, particularly in eye health. We describe the nature and extent of the equity-focused evidence to support and inform eye health programs on the path to universal eye health, and propose ways to improve the collection and reporting of this evidence. Blindness prevalence decreased in all regions of the world between 1990 and 2010, albeit not at the same rate or to the same extent. In 2010, the prevalence of blindness in West Africa (6.0%) remained 15 times higher than in high-income regions (0.4%); within all regions, women had a higher prevalence of blindness than men. Beyond inter-regional and sex differences, there is little comparable data on the distribution of blindness across social groups within regions and countries, or on whether this distribution has changed over time. Similarly, interventions known to address inequity in blindness are few, and equity-relevant goals, targets and indicators for eye health programs are scarce. Equity aims of eye health programs can benefit from the global momentum towards achieving UHC, and the progress being made on collecting, communicating and using equity-focused evidence.

  13. Comparison of photorefractive keratectomy and laser in situ keratomileusis for myopia of -6 D or less using the Nidek EC-5000 laser.

    Science.gov (United States)

    Fernández, A P; Jaramillo, J; Jaramillo, M

    2000-01-01

    We compared the efficacy, predictability, and safety of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) for the surgical correction of low and moderate myopia. A retrospective study was performed to evaluate uncorrected and spectacle-corrected visual acuity, and manifest refraction 1 year after PRK or LASIK. All procedures were done using an automatic microkeratome (Chiron Ophthalmic) and the Nidek EC-5000 excimer laser. PRK was performed in 75 eyes of 45 patients and LASIK in 133 eyes of 77 patients. Mean age for PRK patients was 32.8 years (range, 18 to 52 yr) and LASIK patients was 29.6 years (range, 18 to 49 yr). Mean preoperative spherical equivalent refraction for PRK patients was -3.28 D (range, -1.00 to -6.00 D) and LASIK, -3.86 D (range, -1.00 to -6.00 D). One year after surgery, mean spherical equivalent refraction for Group 1 (baseline, -1.00 to -3.00 D) PRK eyes was -0.18 +/- 0.61 D (range, -1.50 to +0.75 D) and for LASIK eyes, -0.08 +/- 0.61 D (range, -1.50 to +1.62 D), with no statistically significant difference. For Group 2 eyes (baseline, -3.25 to -6.00 D), mean spherical equivalent refraction for PRK eyes was -0.44 +/- 0.87 D (range, -2.00 to +2.12 D) and for LASIK eyes, -0.09 +/- 0.83 D (range, -1.50 to +1.75 D), with no statistically significant difference. The antilogarithm of the mean UCVA (antilogUCVA) in Group 1 for PRK was 0.79 +/- 0.21 (20/25) and for LASIK was 0.87 +/- 0.19 (20/23), with no statistically significant difference. The antilogUCVA in Group 2 for PRK eyes was 0.70 +/- 0.24 (20/28) and for LASIK eyes was 0.83 +/- 0.18 (20/24), with a statistically significant difference (0.7 vs. 0.83, P 20/40 in Group 1 for PRK was 91.5% (38 eyes) and for LASIK was 95% (50 eyes) (no statistically significant difference), and in Group 2 for PRK eyes, it was 82% (27 eyes) and 97.5% (78 eyes) for LASIK (statistically significant difference, P PRK and LASIK with the Nidek EC-5000 excimer laser are effective and safe for

  14. Use of EyeCam for imaging the anterior chamber angle.

    Science.gov (United States)

    Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin

    2010-06-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.

  15. Regularity of Center of Pressure Trajectories in Expert Gymnasts during Bipedal Closed-Eyes Quiet Standing

    Directory of Open Access Journals (Sweden)

    Brice Isableu

    2017-06-01

    Full Text Available We compared postural control of expert gymnasts (G to that of non-gymnasts (NG during bipedal closed-eyes quiet standing using conventional and nonlinear dynamical measures of center of foot pressure (COP trajectories. Earlier findings based on COP classical variables showed that gymnasts exhibited a better control of postural balance but only in demanding stances. We examined whether the effect of expertise in Gymnastic can be uncovered in less demanding stances, from the analysis of the dynamic patterns of COP trajectories. Three dependent variables were computed to describe the subject’s postural behavior: the variability of COP displacements (ACoP, the variability of the COP velocities (VCoP and the sample entropy of COP (SEnCoP to quantify COP regularity (i.e., predictability. Conventional analysis of COP trajectories showed that NG and G exhibited similar amount and control of postural sway, as indicated by similar ACoP and VCoP values observed in NG and G, respectively. These results suggest that the specialized balance training received by G may not transfer to less challenging balance conditions such as the bipedal eyes-closed stance condition used in the present experiment. Interestingly, nonlinear dynamical analysis of COP trajectories regarding COP regularity showed that G exhibited more irregular COP fluctuations relative to NG, as indicated by the higher SEnCoP values observed for the G than for the NG. The present results showed that a finer-grained analysis of the dynamic patterns of the COP displacements is required to uncover an effect of gymnastic expertise on postural control in nondemanding postural stance. The present findings shed light on the surplus value in the nonlinear dynamical analysis of COP trajectories to gain further insight into the mechanisms involved in the control of bipedal posture.

  16. Development of a clinical static and dynamic standing balance measurement tool appropriate for use in adolescents.

    Science.gov (United States)

    Emery, Carolyn A; Cassidy, J David; Klassen, Terry P; Rosychuk, Rhonda J; Rowe, Brian B

    2005-06-01

    There is a need in sports medicine for a static and dynamic standing balance measure to quantify balance ability in adolescents. The purposes of this study were to determine the test-retest reliability of timed static (eyes open) and dynamic (eyes open and eyes closed) unipedal balance measurements and to examine factors associated with balance. Adolescents (n=123) were randomly selected from 10 Calgary high schools. This study used a repeated-measures design. One rater measured unipedal standing balance, including timed eyes-closed static (ECS), eyes-open dynamic (EOD), and eyes-closed dynamic (ECD) balance at baseline and 1 week later. Dynamic balance was measured on a foam surface. Reliability was examined using both intraclass correlation coefficients (ICCs) and Bland and Altman statistical techniques. Multiple linear regressions were used to examine other potentially influencing factors. Based on ICCs, test-retest reliability was adequate for ECS, EOD, and ECD balance (ICC=.69, .59, and .46, respectively). The results of Bland and Altman methods, however, suggest that caution is required in interpreting reliability based on ICCs alone. Although both ECS balance and ECD balance appear to demonstrate adequate test-retest reliability by ICC, Bland and Altman methods of agreement demonstrate sufficient reliability for ECD balance only. Thirty percent of the subjects reached the 180-second maximum on EOD balance, suggesting that this test is not appropriate for use in this population. Balance ability (ECS and ECD) was better in adolescents with no past history of lower-extremity injury. Timed ECD balance is an appropriate and reliable clinical measurement for use in adolescents and is influenced by previous injury.

  17. Advanced surface ablation for presbyopia using the Nidek EC-5000 laser.

    Science.gov (United States)

    Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Victor; Bonilla, Julio

    2004-01-01

    To present 1 to 6-month follow-up results of laser in situ keratomileusis (LASIK) using multizone presbyopic advanced surface ablation (PASA) with a peripheral near zone. LASIK was performed on 28 eyes of 17 patients (10 men and 7 women; mean age 49.8 years with a range of 37 to 62 years). Eyes had primary or enhancement treatments with the Nidek EC-5000 excimer laser. Three techniques were used: 1) total transepithelial ablation, 2) surface ablation for far vision ametropia correction, and 3) concentric peripheral near zone presbyopia correction (technique developed by Dr. A. Telandro with a modified nomogram by Dr. R. Cantú for surface ablation). One surgeon (RC) performed all surgery. We present the preoperative and postoperative measurements for far and near uncorrected visual acuity, total high order aberrations, spherical aberration (Z-12), asphericity Q index, eccentricity corneal shape factor, and total coma and trefoil aberrations. Increases occurred in negative spherical aberration, negative asphericity index, and positive eccentricity corneal shape factor. Advanced surface ablation for presbyopia with a concentric peripheral near zone is a promising approach for surgical correction of presbyopia and potentially could be used with any advanced surface ablation procedure. Increases in negative spherical aberration and asphericity/ eccentricity indices seemed to increase the depth of focus of the eye, improving the near vision.

  18. Application of ECS to a hybrid automobile; `ECS` no hybrid jidosha eno tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M.; Okamura, T.

    1997-01-30

    This paper describes a simulation for a case when an energy capacitor system (ECS) is mounted in a hybrid electric vehicle in place of secondary batteries. The ECS is electric power storage equipment consisted of capacitors and electronic circuits, and capable of quick charge and discharge at high efficiency. Its energy density per unit weight is about the same as lead-acid batteries, but its output density is greater than any type of batteries. Being free of deterioration due to charge and discharge, its cycle life is almost limitless. In order to suppress heat generation, a switching converter is used to control the output to about 300W. However, internal resistance of an ECS is smaller than in an equivalent secondary battery, and internal loss and heat generation stay as low as 1/5 to 1/10. Discussions have been given on cases of using the ECS in small passenger cars, small buses/trucks, and large buses. Since the ECS can use the stored power to about 94% of the capacity, and its cycle life is sufficiently long, it can operate with charge capacity as small as 1/4 of a lead-acid battery. The weight can also be reduced largely. Regenerative power storage efficiency is high, fuel consumption can be improved, heat generation is less, and no forced cooling is required. 9 refs., 4 figs., 1 tab.

  19. Eye-closure helps memory by reducing cognitiveload and enhancing visualisation

    NARCIS (Netherlands)

    Vredeveldt, A.; Hitch, G.J.; Baddeley, A.D.

    2011-01-01

    Closing the eyes helps memory. We investigated the mechanisms underlying the eyeclosure effect by exposing 80 eyewitnesses to different types of distraction during the witness interview: blank screen (control), eyes closed, visual distraction, and auditory distraction. We examined the cognitive load

  20. Distinct eye movement patterns enhance dynamic visual acuity

    Science.gov (United States)

    Palidis, Dimitrios J.; Wyder-Hodge, Pearson A.; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics—eye latency, acceleration, velocity gain, position error—and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns—minimizing eye position error, tracking smoothly, and inhibiting reverse saccades—were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA. PMID:28187157

  1. Distinct eye movement patterns enhance dynamic visual acuity.

    Science.gov (United States)

    Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.

  2. Juvenile eye growth, when completed?

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Christensen, Anders S; Fledelius, Christian

    2014-01-01

    PURPOSE: To test Sorsby's classical statement of axial eye growth as completed at the age of 13 years, with a view also to differentiating between basic eye growth and juvenile elongation associated with eventual refractive change towards myopia. METHODS: (i) A total of 160 healthy eyes close...... about age 13 as general limit found support from the cross-sectional data, which suggested stable emmetropic eye size from about 11-12 years, with an average apparently outgrown male emmetropic value of 23.5 mm versus females' 22.9 mm. The longitudinal data, however, showed emmetropic growth also beyond...

  3. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  4. The effectiveness of eye-closure in repeated interviews

    NARCIS (Netherlands)

    Vredeveldt, A.; Baddeley, A.D.; Hitch, G.J.

    2014-01-01

    Purpose Closing the eyes during recall can help witnesses remember more about a witnessed event. This study examined the effectiveness of eye-closure in a repeated recall paradigm with immediate free recall followed 1 week later by both free and cued recall. We examined whether eye-closure was more

  5. 78 FR 28233 - National Eye Institute; Notice of Closed Meeting

    Science.gov (United States)

    2013-05-14

    ..., National Eye Institute, Bethesda, MD 20892, (301) 451-6763. In the interest of security, NIH has instituted stringent procedures for entrance onto the NIH campus. All visitor vehicles, including taxicabs, hotel, and...

  6. Developmental regulation of ecdysone receptor (EcR and EcR-controlled gene expression during pharate-adult development of honeybees (Apis mellifera.

    Directory of Open Access Journals (Sweden)

    Tathyana Rachel Palo Mello

    2014-12-01

    Full Text Available Major developmental transitions in multicellular organisms are driven by steroid hormones. In insects, these, together with juvenile hormone (JH, control development, metamorphosis, reproduction and aging, and are also suggested to play an important role in caste differentiation of social insects. Here, we aimed to determine how EcR transcription and ecdysteroid titers are related during honeybee postembryonic development and what may actually be the role of EcR in caste development of this social insect. In addition, we expected that knocking-down EcR gene expression would give us information on the participation of the respective protein in regulating downstream targets of EcR. We found that in Apis mellifera females, EcR-A is the predominantly expressed variant in postembryonic development, while EcR-B transcript levels are higher in embryos, indicating an early developmental switch in EcR function. During larval and pupal stages, EcR-B expression levels are very low, while EcR-A transcripts are more variable and abundant in workers compared to queens. Strikingly, these transcript levels are opposite to the ecdysteroid titer profile. 20-hydroxyecdysone (20E application experiments revealed that low 20E levels induce EcR expression during development, whereas high ecdysteroid titers seem to be repressive. By means of RNAi-mediated knockdown (KD of both EcR transcript variants we detected the differential expression of 234 poly-A+ transcripts encoding genes such as CYPs, MRJPs and certain hormone response genes (Kr-h1 and ftz-f1. EcR-KD also promoted the differential expression of 70 miRNAs, including highly conserved ones (e.g. miR-133 and miR-375, as well honeybee-specific ones (e.g. miR-3745 and miR-3761. Our results put in evidence a broad spectrum of EcR-controlled gene expression during postembryonic development of honeybees, revealing new facets of EcR biology in this social insect.

  7. Angle assessment by EyeCam, goniophotography, and gonioscopy.

    Science.gov (United States)

    Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2012-09-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.

  8. EC6 safety design improvements

    Energy Technology Data Exchange (ETDEWEB)

    Yu, S.; Lee, A.G.; Soulard, M. [Candu Energy Inc., Mississauga, ON (Canada)

    2014-07-01

    The Enhanced CANDU 6 (EC6) builds on the proven high performance design such as the Qinshan CANDU 6 reactor, and has made improvements to safety, operational performance, and has incorporated extensive operational feedback. Completion of all three phases of the pre-licensing design review by the Canadian Regulator - the Canadian Nuclear Safety Commission has provided a higher level of assurance that the EC6 reference design has taken modern regulatory requirements and expectations into account and further confirmed that there are no fundamental barriers to licensing the EC6 design in Canada. The EC6 design is based on the defence-in-depth principles in INSAG-10 and provides further safety features that address the lessons learned from Fukushima. With these safety features, the EC6 design has strengthened accident prevention as the first priority in the defence-in-depth strategy, as outlined in INSAG-10. As well, the EC6 design has incorporated further mitigation measures to provide additional protection of the public and the environment if the preventive measures fail. The EC6 design has an appropriate combination of inherent, passive safety characteristics, engineered features and administrative safety measures to effectively prevent and mitigate severe accident progressions. A strong contributor to the robustness and redundancy of CANDU design is the two-group separation philosophy. This ensures a high degree of independence between safety systems as well as physical separation and functional independence in how fundamental safety functions are provided. This paper will describe the following safety features based on the application of defence-in-depth and design approach to prevent beyond design basis events progressing to severe accidents and to mitigate the consequences if it occurs: Improved steam generator heat sink via a more reliable emergency heat removal system; Increased time before manual field actions are required via enhanced capacity of

  9. Self-Motion Perception during Locomotor Recalibration: More than Meets the Eye

    Science.gov (United States)

    Durgin, Frank H.; Pelah, Adar; Fox, Laura F.; Lewis, Jed; Kane, Rachel; Walley, Katherine A.

    2005-01-01

    Do locomotor after effects depend specifically on visual feedback? In 7 experiments, 116 college students were tested, with closed eyes, at stationary running or at walking to a previewed target after adaptation, with closed eyes, to treadmill locomotion. Subjects showed faster inadvertent drift during stationary running and increased distance…

  10. The EC-ASEAN COGEN programme

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, M.; Lacrosse, L. [Asian Institute of Technology (Thailand); Schenkel, Y. [Centre de Recherches Agronomiques (Belgium)

    1996-12-31

    The EC-ASEAN COGEN Programme is a co-operation programme between the European Commission (EC) and the Association of South East Asian Nations (ASEAN) co-ordinated by the Asian Institute of Technology (AIT), Bangkok, Thailand. Its aim is to accelerate the implementation of proven technologies generating heat and/or power from wood and agroindustrial residues through partnerships between European and ASEAN companies. (orig.)

  11. The EC-ASEAN COGEN programme

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, M; Lacrosse, L [Asian Institute of Technology (Thailand); Schenkel, Y [Centre de Recherches Agronomiques (Belgium)

    1997-12-31

    The EC-ASEAN COGEN Programme is a co-operation programme between the European Commission (EC) and the Association of South East Asian Nations (ASEAN) co-ordinated by the Asian Institute of Technology (AIT), Bangkok, Thailand. Its aim is to accelerate the implementation of proven technologies generating heat and/or power from wood and agroindustrial residues through partnerships between European and ASEAN companies. (orig.)

  12. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Directory of Open Access Journals (Sweden)

    Colleen T O'Rourke

    Full Text Available BACKGROUND: Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. METHODOLOGY/PRINCIPAL FINDINGS: We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33° and wide blind areas (∼82°, but intermediate degree of eye movement (∼5°, which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°, small blind areas (∼60°, and high degree of eye movement (∼8°, which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1° may help stabilize the image when hovering above prey before an attack. CONCLUSIONS: We conclude that: (a there are between-species differences in visual field configuration in these diurnal raptors; (b these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats; (c variations in the degree of eye movement between species appear associated with foraging strategies; and (d the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence

  13. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Science.gov (United States)

    O'Rourke, Colleen T; Hall, Margaret I; Pitlik, Todd; Fernández-Juricic, Esteban

    2010-09-22

    Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33°) and wide blind areas (∼82°), but intermediate degree of eye movement (∼5°), which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°), small blind areas (∼60°), and high degree of eye movement (∼8°), which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1°) may help stabilize the image when hovering above prey before an attack. We conclude that: (a) there are between-species differences in visual field configuration in these diurnal raptors; (b) these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats); (c) variations in the degree of eye movement between species appear associated with foraging strategies; and (d) the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence behavioral strategies to visually search for and track prey while

  14. Evaluation of the size segregation of elemental carbon (EC emission in Europe: influence on the simulation of EC long-range transportation

    Directory of Open Access Journals (Sweden)

    Y. Chen

    2016-02-01

    Full Text Available Elemental Carbon (EC has a significant impact on human health and climate change. In order to evaluate the size segregation of EC emission in the EUCAARI inventory and investigate its influence on the simulation of EC long-range transportation in Europe, we used the fully coupled online Weather Research and Forecasting/Chemistry model (WRF-Chem at a resolution of 2 km focusing on a region in Germany, in conjunction with a high-resolution EC emission inventory. The ground meteorology conditions, vertical structure and wind pattern were well reproduced by the model. The simulations of particle number and/or mass size distributions were evaluated with observations at the central European background site Melpitz. The fine mode particle concentration was reasonably well simulated, but the coarse mode was substantially overestimated by the model mainly due to the plume with high EC concentration in coarse mode emitted by a nearby point source. The comparisons between simulated EC and Multi-angle Absorption Photometers (MAAP measurements at Melpitz, Leipzig-TROPOS and Bösel indicated that the coarse mode EC (ECc emitted from the nearby point sources might be overestimated by a factor of 2–10. The fraction of ECc was overestimated in the emission inventory by about 10–30 % for Russia and 5–10 % for Eastern Europe (e.g., Poland and Belarus. This incorrect size-dependent EC emission results in a shorter atmospheric life time of EC particles and inhibits the long-range transport of EC. A case study showed that this effect caused an underestimation of 20–40 % in the EC mass concentration in Germany under eastern wind pattern.

  15. The effectiveness of eye-closure in repeated interviews

    OpenAIRE

    Vredeveldt, A.; Baddeley, A.D.; Hitch, G.J.

    2014-01-01

    Purpose Closing the eyes during recall can help witnesses remember more about a witnessed event. This study examined the effectiveness of eye-closure in a repeated recall paradigm with immediate free recall followed 1 week later by both free and cued recall. We examined whether eye-closure was more or less effective during the second free-recall attempt compared with the first, whether eye-closure during the first recall attempt had an impact on subsequent free- and cued-recall performance, a...

  16. Roles of major organizations in EC for decision making. EC no ishi kettei ni okeru shuyo kikan no yakuwari

    Energy Technology Data Exchange (ETDEWEB)

    Kodama, M.

    1992-12-01

    This paper considers authorization powers held by the major organizations in the EC, with the Maastricht Treaty kept in mind. One of the objectives of establishing the EC is to harmonize and develop the economic activities in the community on the whole, and promote making closer the relations among the member nations. The EC's supernationality has two aspects: finances (using financial sources from externally common tariffs as the EC's independent financial resources) and legislations (member nations delegating their own powers to the international organization). Organizations involving in the EC legislations are the European Assembly, the board of ministers, and the EC Committee. The Assembly has deciding powers at high levels on the EC budget decision, as well as vetoing power on the budget. The board of ministers is provided with deciding powers to assure achievement of the objectives defined in the official requirements. The Committee has a supernational character that each committee member can act independently free from being subjected to orders from his or her native country. Practically, however, the authorization relationship among the organizations has confrontations over the interests of the organizations and member nations. There have been such movements in this situation as the Luxemburg compromises, actions at the agricultural ministers meeting, and preparation of the unified European protocol. 2 figs., 4 tabs.

  17. Public Availability to ECS Collected Datasets

    Science.gov (United States)

    Henderson, J. F.; Warnken, R.; McLean, S. J.; Lim, E.; Varner, J. D.

    2013-12-01

    Coastal nations have spent considerable resources exploring the limits of their extended continental shelf (ECS) beyond 200 nm. Although these studies are funded to fulfill requirements of the UN Convention on the Law of the Sea, the investments are producing new data sets in frontier areas of Earth's oceans that will be used to understand, explore, and manage the seafloor and sub-seafloor for decades to come. Although many of these datasets are considered proprietary until a nation's potential ECS has become 'final and binding' an increasing amount of data are being released and utilized by the public. Data sets include multibeam, seismic reflection/refraction, bottom sampling, and geophysical data. The U.S. ECS Project, a multi-agency collaboration whose mission is to establish the full extent of the continental shelf of the United States consistent with international law, relies heavily on data and accurate, standard metadata. The United States has made it a priority to make available to the public all data collected with ECS-funding as quickly as possible. The National Oceanic and Atmospheric Administration's (NOAA) National Geophysical Data Center (NGDC) supports this objective by partnering with academia and other federal government mapping agencies to archive, inventory, and deliver marine mapping data in a coordinated, consistent manner. This includes ensuring quality, standard metadata and developing and maintaining data delivery capabilities built on modern digital data archives. Other countries, such as Ireland, have submitted their ECS data for public availability and many others have made pledges to participate in the future. The data services provided by NGDC support the U.S. ECS effort as well as many developing nation's ECS effort through the U.N. Environmental Program. Modern discovery, visualization, and delivery of scientific data and derived products that span national and international sources of data ensure the greatest re-use of data and

  18. 76 FR 58521 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2011-09-21

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory... and Training, Nat. Institute of Environmental Health Science, P. O. Box 12233, MD EC-30/Room 3170 B... Extramural Research and Training, Nat. Institute of Environmental Health Sciences, P. O. Box 12233, MD EC-30...

  19. Eye dose assessment and management: overview

    International Nuclear Information System (INIS)

    Rehani, M.M.

    2015-01-01

    Some publications have shown that Hp( 0.07 ) or even Hp( 10 ) can be used as good operational quantities for X-rays in view of difficulties with Hp( 3 ). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 1808 plus cone angle of the X-ray tube and with tube under scan arcs. (authors)

  20. Dual EC : a standardized back door

    NARCIS (Netherlands)

    Bernstein, D.J.; Lange, T.; Niederhagen, R.F.

    2015-01-01

    Dual EC is an algorithm to compute pseudorandom numbers starting from some random input. Dual EC was standardized by NIST, ANSI, and ISO among other algorithms to generate pseudorandom numbers. For a long time this algorithm was considered suspicious -- the entity designing the algorithm could have

  1. Programming Amazon EC2

    CERN Document Server

    Vliet, Jurg

    2011-01-01

    If you plan to use Amazon Web Services to run applications in the cloud, the end-to-end approach in this book will save you needless trial and error. You'll find practical guidelines for designing and building applications with Amazon Elastic Compute Cloud (EC2) and a host of supporting AWS tools, with a focus on critical issues such as load balancing, monitoring, and automation. How do you move an existing application to AWS, or design your application so that it scales effectively? How much storage will you require? Programming Amazon EC2 not only helps you get started, it will also keep y

  2. Evaluation of the size segregation of elemental carbon (EC) emission in Europe: Influence on the simulation of EC long-range transportation

    NARCIS (Netherlands)

    Chen, Y.; Cheng, Y.F.; Nordmann, S.; Birmili, W.; Denier Van Der Gon, H.A.C.; Ma, N.; Wolke, R.; Wehner, B.; Sun, J.; Spindler, G.; Mu, Q.; Pöschl, U.; Su, H.; Wiedensohler, A.

    2016-01-01

    Elemental Carbon (EC) has a significant impact on human health and climate change. In order to evaluate the size segregation of EC emission in the EUCAARI inventory and investigate its influence on the simulation of EC long-range transportation in Europe, we used the fully coupled online Weather

  3. LASIK - Laser Eye Surgery

    Science.gov (United States)

    ... Refractive Surgery Procedures What Is Photorefractive Keratectomy (PRK)? LASIK — Laser Eye Surgery Leer en Español: LASIK—Cirugía ocular con láser ... loss of close-up focusing power. How the LASIK procedure works LASIK is performed while the patient ...

  4. Investigating the center of pressure velocity Romberg's quotient for assessing the visual role on the body sway

    OpenAIRE

    Silva, Paulo José Guimarães da; Nadal, Jurandir; Infantosi, Antonio Fernando Catelli

    2012-01-01

    The classical Romberg's test based on stabilometric tests in eyes open (EO) and closed (EC) conditions was used for investigating the influence of visual feedback in the body sway control in healthy adult subjects. Stabilograms from 144 subjects (aged 18-40) resting over a force platform were recorded for 30 s in EO and 30 s in EC conditions. The mean velocity was obtained for EO (VmEO) and EC (VmEC) in both anterior-posterior (y) and medial-lateral (x) directions and in the (x,y) plane, and ...

  5. Contextual effects on motion perception and smooth pursuit eye movements.

    Science.gov (United States)

    Spering, Miriam; Gegenfurtner, Karl R

    2008-08-15

    Smooth pursuit eye movements are continuous, slow rotations of the eyes that allow us to follow the motion of a visual object of interest. These movements are closely related to sensory inputs from the visual motion processing system. To track a moving object in the natural environment, its motion first has to be segregated from the motion signals provided by surrounding stimuli. Here, we review experiments on the effect of the visual context on motion processing with a focus on the relationship between motion perception and smooth pursuit eye movements. While perception and pursuit are closely linked, we show that they can behave quite distinctly when required by the visual context.

  6. Disulfide-stabilized Helical Hairpin Structure and Activity of a Novel Antifungal Peptide EcAMP1 from Seeds of Barnyard Grass (Echinochloa crus-galli)*

    Science.gov (United States)

    Nolde, Svetlana B.; Vassilevski, Alexander A.; Rogozhin, Eugene A.; Barinov, Nikolay A.; Balashova, Tamara A.; Samsonova, Olga V.; Baranov, Yuri V.; Feofanov, Alexey V.; Egorov, Tsezi A.; Arseniev, Alexander S.; Grishin, Eugene V.

    2011-01-01

    This study presents purification, activity characterization, and 1H NMR study of the novel antifungal peptide EcAMP1 from kernels of barnyard grass Echinochloa crus-galli. The peptide adopts a disulfide-stabilized α-helical hairpin structure in aqueous solution and thus represents a novel fold among naturally occurring antimicrobial peptides. Micromolar concentrations of EcAMP1 were shown to inhibit growth of several fungal phytopathogens. Confocal microscopy revealed intensive EcAMP1 binding to the surface of fungal conidia followed by internalization and accumulation in the cytoplasm without disturbance of membrane integrity. Close spatial structure similarity between EcAMP1, the trypsin inhibitor VhTI from seeds of Veronica hederifolia, and some scorpion and cone snail toxins suggests natural elaboration of different functions on a common fold. PMID:21561864

  7. Disulfide-stabilized helical hairpin structure and activity of a novel antifungal peptide EcAMP1 from seeds of barnyard grass (Echinochloa crus-galli).

    Science.gov (United States)

    Nolde, Svetlana B; Vassilevski, Alexander A; Rogozhin, Eugene A; Barinov, Nikolay A; Balashova, Tamara A; Samsonova, Olga V; Baranov, Yuri V; Feofanov, Alexey V; Egorov, Tsezi A; Arseniev, Alexander S; Grishin, Eugene V

    2011-07-15

    This study presents purification, activity characterization, and (1)H NMR study of the novel antifungal peptide EcAMP1 from kernels of barnyard grass Echinochloa crus-galli. The peptide adopts a disulfide-stabilized α-helical hairpin structure in aqueous solution and thus represents a novel fold among naturally occurring antimicrobial peptides. Micromolar concentrations of EcAMP1 were shown to inhibit growth of several fungal phytopathogens. Confocal microscopy revealed intensive EcAMP1 binding to the surface of fungal conidia followed by internalization and accumulation in the cytoplasm without disturbance of membrane integrity. Close spatial structure similarity between EcAMP1, the trypsin inhibitor VhTI from seeds of Veronica hederifolia, and some scorpion and cone snail toxins suggests natural elaboration of different functions on a common fold.

  8. The EC discourse on vocational training

    DEFF Research Database (Denmark)

    Cort, Pia

    2009-01-01

    This article traces the EC vocational training policy historically and describes the discursive alignments which brought the policy from a ‘common vocational training policy' as laid down in Article 128, in the Treaty of Rome to the Lisbon Lifelong Learning strategy. The argument is that vocational...... EC vocational training policy (Ball, What is policy? Texts, trajectories and toolboxes. Discourse, 13(2), 1993)....

  9. GABA(A) receptors in visual and auditory cortex and neural activity changes during basic visual stimulation.

    Science.gov (United States)

    Qin, Pengmin; Duncan, Niall W; Wiebking, Christine; Gravel, Paul; Lyttelton, Oliver; Hayes, Dave J; Verhaeghe, Jeroen; Kostikov, Alexey; Schirrmacher, Ralf; Reader, Andrew J; Northoff, Georg

    2012-01-01

    Recent imaging studies have demonstrated that levels of resting γ-aminobutyric acid (GABA) in the visual cortex predict the degree of stimulus-induced activity in the same region. These studies have used the presentation of discrete visual stimulus; the change from closed eyes to open also represents a simple visual stimulus, however, and has been shown to induce changes in local brain activity and in functional connectivity between regions. We thus aimed to investigate the role of the GABA system, specifically GABA(A) receptors, in the changes in brain activity between the eyes closed (EC) and eyes open (EO) state in order to provide detail at the receptor level to complement previous studies of GABA concentrations. We conducted an fMRI study involving two different modes of the change from EC to EO: an EO and EC block design, allowing the modeling of the haemodynamic response, followed by longer periods of EC and EO to allow the measuring of functional connectivity. The same subjects also underwent [(18)F]Flumazenil PET to measure GABA(A) receptor binding potentials. It was demonstrated that the local-to-global ratio of GABA(A) receptor binding potential in the visual cortex predicted the degree of changes in neural activity from EC to EO. This same relationship was also shown in the auditory cortex. Furthermore, the local-to-global ratio of GABA(A) receptor binding potential in the visual cortex also predicted the change in functional connectivity between the visual and auditory cortex from EC to EO. These findings contribute to our understanding of the role of GABA(A) receptors in stimulus-induced neural activity in local regions and in inter-regional functional connectivity.

  10. GABAA receptors in visual and auditory cortex and neural activity changes during basic visual stimulation

    Directory of Open Access Journals (Sweden)

    Pengmin eQin

    2012-12-01

    Full Text Available Recent imaging studies have demonstrated that levels of resting GABA in the visual cortex predict the degree of stimulus-induced activity in the same region. These studies have used the presentation of discrete visual stimulus; the change from closed eyes to open also represents a simple visual stimulus, however, and has been shown to induce changes in local brain activity and in functional connectivity between regions. We thus aimed to investigate the role of the GABA system, specifically GABAA receptors, in the changes in brain activity between the eyes closed (EC and eyes open (EO state in order to provide detail at the receptor level to complement previous studies of GABA concentrations. We conducted an fMRI study involving two different modes of the change from EC to EO: An EO and EC block design, allowing the modelling of the haemodynamic response, followed by longer periods of EC and EO to allow the measuring of functional connectivity. The same subjects also underwent [18F]Flumazenil PET measure GABAA receptor binding potentials. It was demonstrated that the local-to-global ratio of GABAA receptor binding potential in the visual cortex predicted the degree of changes in neural activity from EC to EO. This same relationship was also shown in the auditory cortex. Furthermore, the local-to-global ratio of GABAA receptor binding potential in the visual cortex also predicts the change of functional connectivity between visual and auditory cortex from EC to EO. These findings contribute to our understanding of the role of GABAA receptors in stimulus-induced neural activity in local regions and in inter-regional functional connectivity.

  11. Finite impulse testing (FIT) system for Emergency Cooling System (ECS) in Dhruva

    International Nuclear Information System (INIS)

    Punekar, Parag; Ramkumar, N.; Kulkarni, U.S.; Darbhea, M.D.; Bharadhwaj, G; Jangra, L.R.; Geetha, Patil; Das, Shantanu; Sonnis, S.T.; Trevedi, P.; Patil, M.B.; Biswas, B.B.

    2006-01-01

    Finite Impulse Testing (FIT) system for Emergency Cooling System (ECS) is used to check healthiness of ECS logic circuits in an online mode. The ECS is an important safety system that ensures the cooling of reactor core during shutdown state of Main Coolant Pumps (MCPs), and hence FIT-ECS that monitors the health of ECS logic circuits in an online (real time) mode is an important part of it. Based on a Safety Related Unusual Occurrence in ECS system due to the malfunction of its earlier single channel FIT system, the new FIT-ECS system has been designed with new features and is commissioned. The FIT-ECS system feeds the simulated input signals (fine impulses of nominal width 575 μS) to the ECS logic circuits and read the outputs. These output (predicted) signals from ECS logic circuit are processed in the FIT-ECS system and in event of any discrepancy, the FIT-ECS system displays fault signature on local panel, detailed information of the fault on Operator Console (OC), and generates an alarm 'ECS logic Fail' in the control room. FIT-ECS also monitors the inputs and outputs of ECS logic circuit. All the information required is stored as a database that can be subsequently displayed in various formats. ECS system is designated as Category I-A system and is a hardwired system and FIT-ECS monitors the healthiness of the logics of the ECS System is a computerized system. As per IEC 1226, FIT-ECS is categorized as Category I-B system. This paper provides technical information on FIT-ECS system design, its important features, the testing carried on the FIT-ECS system, interconnections of FIT-ECS and ECS and the commissioning experience of FIT-ECS system. (author)

  12. Lateral information transfer across saccadic eye movements.

    Science.gov (United States)

    Jüttner, M; Röhler, R

    1993-02-01

    Our perception of the visual world remains stable and continuous despite the disruptions caused by retinal image displacements during saccadic eye movements. The problem of visual stability is closely related to the question of whether information is transferred across such eye movements--and if so, what sort of information is transferred. We report experiments carried out to investigate how presaccadic signals at the location of the saccade goal influence the visibility of postsaccadic test signals presented at the fovea. The signals were Landolt rings of different orientations. If the orientations of pre- and postsaccadic Landolt rings were different, the thresholds of the test signals were elevated by about 20%-25% relative to those at the static control condition. When the orientations were identical, no such elevation occurred. This selective threshold elevation effect proved to be a phenomenon different from ordinary saccadic suppression, although it was closely related to the execution of the saccadic eye movement. The consequences for visual stability are discussed.

  13. Everyone talk about EC technology - What's about this technology? AC versus AC technology; Alle reden von EC-Technologie - was bringt sie wirklich? AC- versus EC-Motorentechnik

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-12-15

    Meanwhile, the EC motor technology is the state of the art in fans. In the consciousness of a possible energy conservation, the EC motor technology is demanded to a large extent with the new installations of the customers. But how high are the possible savings actually? A comparative measurement at a condenser of Guentner AG (Fuerstenfeldbruck, Federal Republic of Germany) supports information.

  14. Knowledge, Attitude and Practice of Eye Health Care amongst ...

    African Journals Online (AJOL)

    Objective: To evaluate the knowledge, attitude and practice of eye health care amongst doctors in Lagos. Methodology: Open and closed-ended questionnaires were given to respondents. The questionnaire contained information about age, sex, general knowledge as well as practice of eye care. Results: A total of 104 ...

  15. Novel shadowless imaging for eyes-like diagnosis in vivo

    Science.gov (United States)

    Xue, Ning; Jiang, Kai; Li, Qi; Zhang, Lili; Ma, Li; Huang, Guoliang

    2016-10-01

    Eyes-like diagnosis was a traditional Chinese medicine method for many diseases, such as chronic gastritis, diabetes, hypertension etc. There was a close relationship between viscera and eyes-like. White-Eye was divided into fourteen sections, which corresponded to different viscera, so eyes-like was the reflection of status of viscera, in another words, it was an epitome of viscera health condition. In this paper, we developed a novel shadowless imaging technology and system for eyes-like diagnosis in vivo, which consisted of an optical shadowless imaging device for capturing and saving images of patients' eyes-like, and a computer linked to the device for image processing. A character matching algorithm was developed to extract the character of white-eye in corresponding sections of eyes-like images taken by the optical shadowless imaging device, according to the character of eyes-like, whether there were viscera diseases could be learned. A series of assays were carried out, and the results verified the feasibility of eyes-like diagnosis technique.

  16. SyntEyes KTC: higher order statistical eye model for developing keratoconus.

    Science.gov (United States)

    Rozema, Jos J; Rodriguez, Pablo; Ruiz Hidalgo, Irene; Navarro, Rafael; Tassignon, Marie-José; Koppen, Carina

    2017-05-01

    To present and validate a stochastic eye model for developing keratoconus to e.g. improve optical corrective strategies. This could be particularly useful for researchers that do not have access to original keratoconic data. The Scheimpflug tomography, ocular biometry and wavefront of 145 keratoconic right eyes were collected. These data were processed using principal component analysis for parameter reduction, followed by a multivariate Gaussian fit that produces a stochastic model for keratoconus (SyntEyes KTC). The output of this model is filtered to remove the occasional incorrect topography patterns by either an automatic or manual procedure. Finally, the output of this keratoconus model is matched to that of the original model for normal eyes using the non-corneal biometry to obtain a description of keratoconus development. The synthetic data generated by the model were found to be significantly equal to the original data (non-parametric Mann-Whitney equivalence test; 145/154 passed). The variability of the synthetic data, however, was often significantly less than that of the original data, especially for the higher order Zernike terms of corneal elevation (non-parametric Levene test; p eyes with incorrect topographies. Interpolation between matched pairs of normal and keratoconic SyntEyes appears to provide an adequate model for keratoconus progression. The synthetic data provided by the proposed keratoconus model closely resembles actual clinical data and may be used for a range of research applications when (sufficient) real data is not available. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  17. An efficient closed-form solution for acoustic emission source location in three-dimensional structures

    Directory of Open Access Journals (Sweden)

    Xibing Li

    2014-02-01

    Full Text Available This paper presents an efficient closed-form solution (ECS for acoustic emission(AE source location in three-dimensional structures using time difference of arrival (TDOA measurements from N receivers, N ≥ 6. The nonlinear location equations of TDOA are simplified to linear equations. The unique analytical solution of AE sources for unknown velocity system is obtained by solving the linear equations. The proposed ECS method successfully solved the problems of location errors resulting from measured deviations of velocity as well as the existence and multiplicity of solutions induced by calculations of square roots in existed close-form methods.

  18. Eye-closure increases children’s memory accuracy for visual material

    NARCIS (Netherlands)

    Mastroberardino, S.; Vredeveldt, A.

    2014-01-01

    Research shows that closing the eyes during retrieval can help both adults and children to remember more about witnessed events. In this study, we investigated whether the eye-closure effect in children is explained by general cognitive load, modality-specific interference, or a combination. 120

  19. Survey of eye practitioners' preference of diagnostic tests and treatment modalities for dry eye in Ghana.

    Science.gov (United States)

    Asiedu, Kofi; Kyei, Samuel; Ayobi, Benedict; Agyemang, Frank Okyere; Ablordeppey, Reynolds Kwame

    2016-12-01

    This study sought to provide an evidence-based profile of the diagnosis, treatment and knowledge or opinions on dry eye among optometrists and ophthalmologists in Ghana. This was a cross-sectional survey RESULTS: The responses of 162 participants are included in the analysis. The most commonly used test to diagnosed dry eye disease was tear break-up time followed by patient history. The most common symptom doctors heard from dry eye patients were burning sensation followed by foreign body sensation. The most often prescribed first- line treatment for dry eye was aqueous-based artificial tears followed by lipid-based artificial tears. Most practitioners considered meibomian gland dysfunction as the most common cause of dry eye followed by pterygium. The most often used test to guide or gauge therapeutic effect is patient history followed closely by tear break-up time. Most practitioners reported that 10%-20% of all their patients they see in a day are diagnosed of dry eye. This study showed tear break up time was the main test majority of practitioners in Ghana used to diagnose dry eye but patient history was the main test used to gauge therapeutic effect over time. Burning sensation was the commonest symptom practitioners heard from dry eye patients whilst artificial tears was their main and first-line treatment for dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Association between fundus autofluorescence and visual outcome in surgically closed macular holes.

    Science.gov (United States)

    Lee, Young Seob; Yu, Seung-Young; Cho, Nam Suk; Kim, Moo Sang; Kim, Young Gyun; Kim, Eung Suk; Kwak, Hyung Woo

    2013-06-01

    To investigate the association between fundus autofluorescence (FAF) and visual acuity, recovery of foveal microstructure, and FAF in surgically closed macular holes. Twenty-six eyes with surgically closed macular hole were classified into two groups based on foveal FAF: normal autofluorescence (NAF) or increased autofluorescence (IAF). The association between foveal FAF and visual acuity was analyzed. In addition, we examined the relationship between recovery of the foveal microstructure assessed by spectral domain optical coherence tomography and FAF after macular hole surgery. At 1 month and 6 months after surgery, there were 9 NAF eyes and 17 IAF eyes. There were no differences between NAF and IAF eyes at 1 month and 6 months after surgery. Preoperative best-corrected visual acuity (logarithm of the minimum angle of resolution) did not differ between groups. Best-corrected visual acuity was significantly higher in the NAF group than in the IAF group at 1 month postoperatively (0.59 ± 0.34 vs. 0.91 ± 0.36, P = 0.044) and tended to be higher at 6 months (0.37 ± 0.38 vs. 0.69 ± 0.53, P = 0.126). Restoration of photoreceptor external limiting membrane differed significantly in 8 NAF eyes (89%) and 4 IAF eyes (24%) at postoperation 1 month (P = 0.001). After 6 months, external limiting membrane was restored in all 9 NAF eyes (100%) and in only 11 IAF eyes (65%) (P = 0.042). Fundus autofluorescence findings observed in surgically closed macular holes correlated with visual improvement and photoreceptor status. Eyes with visual improvement had restoration of normal foveal autofluorescence and retinal microstructure, whereas eyes with persistent foveal hyperautofluorescence did not achieve complete restoration of the retinal microstructure, and visual improvement was not as significant.

  1. Therapeutic efficacy of fibroblast growth factor 10 in a rabbit model of dry eye.

    Science.gov (United States)

    Zheng, Wenjing; Ma, Mingming; Du, Ergang; Zhang, Zhengwei; Jiang, Kelimu; Gu, Qing; Ke, Bilian

    2015-11-01

    The aim of the present study was to investigate the therapeutic efficacy of fibroblast growth factor 10 (FGF10) in the promotion of healing, survival and expression of mucin in corneal epithelial cells in a rabbit dry eye model. A total of 12 healthy female New Zealand white rabbits were divided randomly into three groups. The lacrimal glands were injected with saline either alone (normal control group) or with concanavalin A (Con A), with either topical phosphate‑buffered saline (PBS; PBS control group) or 25 µg/ml FGF10 (FGF10 treatment group). Lacrimal gland inflammation, tear function, corneal epithelial cell integrity, cell apoptosis and mucin expression were subsequently assessed. Lacrimal gland tissue biopsies were performed in conjunction with histology and electron microscopy observations. Tear meniscus height (TMH) and tear meniscus area (TMA) were measured using Fourier domain‑optical coherence tomography. Tear membrane break‑up time (TBUT) was also assessed and corneal fluorescein staining was performed. The percentages of apoptotic corneal and conjunctival (Cj) epithelial cells (ECs) were counted using a terminal deoxynucleotidyl transferase‑mediated dUTP nick end labeling method. The mRNA expression levels of Muc1 were determined using reverse transcription‑quantitative polymerase chain reaction analyses. The TMH and TMA values of the PBS and treatment groups were found to be significantly reduced, compared with those of the normal control group 3 days after Con A injection. However, the TMH and TMA of the FGF10 treatment group were higher, compared with those of the PBS group 3 and 7 days after treatment, respectively. Furthermore, the FGF10 treatment group exhibited prolonged TBUT, reduced corneal fluorescein staining and repaired epithelial cell ultrastructure7 days after treatment. The percentages of apoptotic corneal‑ and Cj‑ECs in the FGF10 treatment group were significantly reduced, compared with those in the PBS group. FGF10

  2. Anatomically accurate, finite model eye for optical modeling.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1997-08-01

    There is a need for a schematic eye that models vision accurately under various conditions such as refractive surgical procedures, contact lens and spectacle wear, and near vision. Here we propose a new model eye close to anatomical, biometric, and optical realities. This is a finite model with four aspheric refracting surfaces and a gradient-index lens. It has an equivalent power of 60.35 D and an axial length of 23.95 mm. The new model eye provides spherical aberration values within the limits of empirical results and predicts chromatic aberration for wavelengths between 380 and 750 nm. It provides a model for calculating optical transfer functions and predicting optical performance of the eye.

  3. Fractionated stereotactic irradiation by Cyberknife of choroid melanomas: repositioning validation, closed eyelids

    International Nuclear Information System (INIS)

    Horn, S.; Rezvoy, N.; Lacornerie, T.; Mirabel, X.; Labalette, P.; Lartigau, E.

    2009-01-01

    The fractionated stereotactic radiotherapy by Cyberknife is an option in the treatment of eyes tumors. The advantages of the Cyberknife in the choroid melanomas are in its infra-millimetric precision, to the automated repositioning on the skull bones and to the conformity brought by the stereotaxy. The objective of this study was to validate the quality of repositioning and the immobility of the eyes with closed eyelids. Conclusion: the reproducibility of the eye positioning with closed eyelids seems enough to consider the conservative treatment of choroid melanomas by fractionated stereotactic radiotherapy by Cyberknife without implementation of fiducials nor retrobulbar anaesthesia. (N.C.)

  4. Limiting nutrient emission from a cut rose closed system by high-flux irrigation and low nutrient concentrations?

    NARCIS (Netherlands)

    Baas, R.; Berg, van der D.

    2004-01-01

    A two-year project was aimed at decreasing nutrient emission from closed nutrient systems by using high irrigation rates in order to allow lower EC levels in the presence of accumulated Na and Cl. Experimental variables were growing media, irrigation frequencies, EC and NaCl concentrations for cut

  5. Eye-closure increases children’s memory accuracy for visual material

    Directory of Open Access Journals (Sweden)

    Serena eMastroberardino

    2014-03-01

    Full Text Available Research shows that closing the eyes during retrieval can help both adults and children to remember more about witnessed events. In this study, we investigated whether the eye-closure effect in children is explained by general cognitive load, modality-specific interference, or a combination. 120 children (60 female aged between 8 and 11 years viewed a 5-minute clip depicting a theft and were questioned about the event. During the cued-recall interview, children either viewed a blank screen (blank-screen condition, kept their eyes closed (eye-closure condition, were exposed to visual stimuli (visual-distraction condition, or were exposed to auditory stimuli (auditory-distraction condition. Children in the blank-screen and eye-closure conditions provided significantly more correct and fewer incorrect responses about visual details than children in the visual- and auditory-distraction conditions. No advantage was found for auditory details. These results support neither a pure cognitive-load explanation (in which the effect is expected to be observed for recall of both visual and auditory details, nor a pure modality-specific account (in which recall of visual details should only be disrupted by visual distractions. Practical implications of the findings are discussed.

  6. Eye closure helps memory by reducing cognitive load and enhancing visualisation.

    Science.gov (United States)

    Vredeveldt, Annelies; Hitch, Graham J; Baddeley, Alan D

    2011-10-01

    Closing the eyes helps memory. We investigated the mechanisms underlying the eyeclosure effect by exposing 80 eyewitnesses to different types of distraction during the witness interview: blank screen (control), eyes closed, visual distraction, and auditory distraction. We examined the cognitive load hypothesis by comparing any type of distraction (visual or auditory) with minimal distraction (blank screen or eyes closed). We found recall to be significantly better when distraction was minimal, providing evidence that eyeclosure reduces cognitive load. We examined the modality-specific interference hypothesis by comparing the effects of visual and auditory distraction on recall of visual and auditory information. Visual and auditory distraction selectively impaired memory for information presented in the same modality, supporting the role of visualisation in the eyeclosure effect. Analysis of recall in terms of grain size revealed that recall of basic information about the event was robust, whereas recall of specific details was prone to both general and modality-specific disruptions.

  7. On the isolation of elemental carbon (EC) for micro-molar 14C accelerator mass spectrometry: development of a hybrid reference material for 14C-EC accuracy assurance, and a critical evaluation of the thermal optical kinetic (TOK) EC isolation procedure

    Science.gov (United States)

    Currie, L. A.; Kessler, J. D.

    2005-10-01

    The primary objective of the research reported here has been the development of a hybrid reference material (RM) to serve as a test of accuracy for elemental carbon (EC) isotopic (14C) speciation measurements. Such measurements are vital for the quantitative apportionment of fossil and biomass sources of "soot" (EC), the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement quality, carried out with NIST SRM 1649a (Urban Dust), showed a range of results, but since the "truth" was not known for this natural matrix RM, one had to rely on isotopic-chemical consistency evidence (14C in PAH, EC) of measurement validity (Currie et al., 2002). Components of the new Hybrid RM (DiesApple), however, have known 14C and EC composition, and they are nearly orthogonal (isotopically and chemically). NIST SRM 2975 (Forklift Diesel Soot) has little or no 14C, and its major compositional component is EC; SRM 1515 (Apple Leaves) has the 14C content of biomass-C, and it has little or no EC. Thus, the Hybrid RM can serve as an absolute isotopic test for the absence of EC-mimicking pyrolysis-C (char) from SRM 1515 in the EC isolate of the Hybrid RM, as well as a test for conservation of its dominant soot fraction throughout the isolation procedure. The secondary objective was to employ the Hybrid RM for the comparative evaluation of the thermal optical kinetic (TOK) and thermal optical transmission (TOT) methods for the isolation of EC for micro-molar carbon accelerator mass spectrometry (AMS). As part of this process, the relatively new TOK method was subjected to a critical evaluation and significant development. Key findings of our study are: (1) both methods exhibited biomass-C "leakage"; for TOT, the EC fraction isolated for AMS contained about 8% of the original biomass-C; for TOK, the refractory carbon (RC) isolated contained about 3% of the original biomass-C.; (2) the initial isothermal oxidation stage of

  8. On the isolation of elemental carbon (EC for micro-molar 14C accelerator mass spectrometry: development of a hybrid reference material for 14C-EC accuracy assurance, and a critical evaluation of the thermal optical kinetic (TOK EC isolation procedure

    Directory of Open Access Journals (Sweden)

    L. A. Currie

    2005-01-01

    Full Text Available The primary objective of the research reported here has been the development of a hybrid reference material (RM to serve as a test of accuracy for elemental carbon (EC isotopic (14C speciation measurements. Such measurements are vital for the quantitative apportionment of fossil and biomass sources of 'soot' (EC, the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement quality, carried out with NIST SRM 1649a (Urban Dust, showed a range of results, but since the 'truth' was not known for this natural matrix RM, one had to rely on isotopic-chemical consistency evidence (14C in PAH, EC of measurement validity (Currie et al., 2002. Components of the new Hybrid RM (DiesApple, however, have known 14C and EC composition, and they are nearly orthogonal (isotopically and chemically. NIST SRM 2975 (Forklift Diesel Soot has little or no 14C, and its major compositional component is EC; SRM 1515 (Apple Leaves has the 14C content of biomass-C, and it has little or no EC. Thus, the Hybrid RM can serve as an absolute isotopic test for the absence of EC-mimicking pyrolysis-C (char from SRM 1515 in the EC isolate of the Hybrid RM, as well as a test for conservation of its dominant soot fraction throughout the isolation procedure. The secondary objective was to employ the Hybrid RM for the comparative evaluation of the thermal optical kinetic (TOK and thermal optical transmission (TOT methods for the isolation of EC for micro-molar carbon accelerator mass spectrometry (AMS. As part of this process, the relatively new TOK method was subjected to a critical evaluation and significant development. Key findings of our study are: (1 both methods exhibited biomass-C 'leakage'; for TOT, the EC fraction isolated for AMS contained about 8% of the original biomass-C; for TOK, the refractory carbon (RC isolated contained about 3% of the original biomass-C.; (2 the initial isothermal oxidation stage

  9. Eye Safety in Dentistry and Associated Liability.

    Science.gov (United States)

    Arsenault, Peter; Tayebi, Amad

    2016-01-01

    The first objective of this article is to expressan experimental-work-supported opinion ofits authors regarding the inadequacy of thepresent dental mask and regular eyewearcombination for protecting dental care practitioners. Its second objective is to suggestamending OSHA Standard 1910.133(a)(1) tomandate effective eye protection for dentalcare practitioners by requiring the use ofeffective means for closing the bottom gapsbetween the lower rims of the lenses of theprotective eyewear and the upper edge ofthe mask worn by the practitioner.The various types and sources of dentalpractice eye occupational hazards and thepossible entry routes of dental debris towarddental practitioners'eyes are discussed.Experimental work, confirming theinadequacy of the present dental mask andeyewear combination for protecting dentalcare practitioners, is presented.

  10. EC-construction product guideline 89/106/EEC and EC-pressure equipement guideline 97/23/EC; EG-Bauproduktenrichtlinie 89/106/EWG und EG-Druckgeraeterichtlinie 97/23/EG

    Energy Technology Data Exchange (ETDEWEB)

    Dupin, F. [DVGW Deutscher Verein des Gas- und Wasserfaches e.V., Bonn (Germany)

    1998-08-01

    For now nearly ten years the EC-directive 90/396/EEC is well established in the gas field. In the meantime other EC-directives are playing a role which cannot be left out of consideration. Particularly the EC-Construction Product Directive (89/106/EEC) and the Pressure Equipment Directive (97/23/EG) constitute a focal point as many key-issues (e.g. scope) are still open, causing thus hotly debated discussions. The present contribution reflects the current consultations at the national and European level, pointing out then the gas-specific features. (orig.) [Deutsch] Seit nahezu zehn Jahren hat sich die EG-Richtlinie 90/396/EWG fuer Gasverbrauchseinrichtungen im europaeischen Gasfach fest etabliert. Inzwischen sind andere EG-Richtlinien ins Spiel gekommen, deren Einfluss nicht ausser Acht gelassen werden kann. Besonders die EG-Bauproduktenrichtlinie (89/106/EWG) und die EG-Druckgeraeterichtlinie (97/23/EG) stehen z.Z. im Mittelpunkt, da viele Schluesselfragen (z.B. Geltungsbereich) noch offen sind und heftige Debatten mit sich bringen. Der vorliegende Beitrag gibt den Stand der auf nationaler und europaeischer Ebene gefuehrten Beratungen wieder und stellt dabei die gasspezifischen Gegebenheiten heraus. (orig.)

  11. Structure and optics of the eyes of the box jellyfish Chiropsella bronzie

    DEFF Research Database (Denmark)

    O’Connor, Megan; Garm, Anders Lydik; Nilsson, Dan-E.

    2009-01-01

    Cubomedusae have a total of 24 eyes of four morphologically different types. Two of these eye types are camera-type eyes (upper and lower lens-eye), while the other two eye types are simpler pigment pit eyes (pit and slit eye). Here, we give a description of the visual system of the box jellyfish...... those in the previously investigated species Tripedalia cystophora. In the lower lens-eye of C. bronzie, blur circles subtend 20 and 52° for closed and open pupil, respectively, effectively removing all but the coarsest structures of the image. Histology reveals that the retina of the lower lens...

  12. Feasibility study on retinal vascular bypass surgery in isolated arterially perfused caprine eye model

    Science.gov (United States)

    Chen, Y; Wu, W; Zhang, X; Fan, W; Shen, L

    2011-01-01

    Purpose To investigate the feasibility of bypassing occluded segments of retinal venous main vessels in isolated, arterially perfused caprine eyes via the closed-sky vitrectomy approach using keratoprosthesis. Methods Isolated caprine eyes were used in this study. For each eye, the retinal vessel was perfused by Krebs solution via ophthalmic artery, and pars plana vitrectomy was performed using temporary keratoprosthesis. All retinal micro-vascular maneuvers were performed in a closed-sky eyeball. The main retinal vein was blocked by endodiathermy at the site of the vessel's first branching. Two openings, several millimeters apart, were created by vascular punctures in both the main vein and its branch vein wall straddling the induced occluded segment. Catheterization was achieved using a flexible polyimide tube, with each end inserted into the vessel wall opening. A sealed connection between the vessel and the tube was obtained by endodiathermy. Bypass of the occluded retinal vein segment was thus achieved, and the patency of this vascular bypass was confirmed by intravascular staining. Results Puncturing, catheterization, and endodiathermy were viable by closed-sky approach using keratoprosthesis. Bypassing of the occluded retinal main vein segment was accomplished with the combination of these maneuvers. Good results were obtained in 23 of 38 (60%) caprine eyes. Conclusions This study demonstrated that bypassing the occluded segment of retinal main vein can be successfully performed in a closed-sky eyeball model of isolated, arterially perfused caprine eye. This early work indicated that the more advanced retinal vascular bypass surgery in in vivo eye may be feasible in the future. PMID:21921946

  13. Metabolic connectivity mapping reveals effective connectivity in the resting human brain.

    Science.gov (United States)

    Riedl, Valentin; Utz, Lukas; Castrillón, Gabriel; Grimmer, Timo; Rauschecker, Josef P; Ploner, Markus; Friston, Karl J; Drzezga, Alexander; Sorg, Christian

    2016-01-12

    Directionality of signaling among brain regions provides essential information about human cognition and disease states. Assessing such effective connectivity (EC) across brain states using functional magnetic resonance imaging (fMRI) alone has proven difficult, however. We propose a novel measure of EC, termed metabolic connectivity mapping (MCM), that integrates undirected functional connectivity (FC) with local energy metabolism from fMRI and positron emission tomography (PET) data acquired simultaneously. This method is based on the concept that most energy required for neuronal communication is consumed postsynaptically, i.e., at the target neurons. We investigated MCM and possible changes in EC within the physiological range using "eyes open" versus "eyes closed" conditions in healthy subjects. Independent of condition, MCM reliably detected stable and bidirectional communication between early and higher visual regions. Moreover, we found stable top-down signaling from a frontoparietal network including frontal eye fields. In contrast, we found additional top-down signaling from all major clusters of the salience network to early visual cortex only in the eyes open condition. MCM revealed consistent bidirectional and unidirectional signaling across the entire cortex, along with prominent changes in network interactions across two simple brain states. We propose MCM as a novel approach for inferring EC from neuronal energy metabolism that is ideally suited to study signaling hierarchies in the brain and their defects in brain disorders.

  14. Impact of Dry Eye Disease on Work Productivity, and Patients' Satisfaction With Over-the-Counter Dry Eye Treatments.

    Science.gov (United States)

    Nichols, Kelly K; Bacharach, Jason; Holland, Edward; Kislan, Thomas; Shettle, Lee; Lunacsek, Orsolya; Lennert, Barb; Burk, Caroline; Patel, Vaishali

    2016-06-01

    To assess the effect of dry eye disease on work productivity and performance of non-work-related activities, and patients' satisfaction with over-the-counter (OTC) dry eye treatments. In this prospective, noninterventional, cross-sectional study, conducted at 10 U.S. optometry/ophthalmology practices, 158 symptomatic dry eye patients naïve to prescription medication underwent standard dry eye diagnostic tests and completed Work Productivity and Activity Impairment (WPAI) and Ocular Surface Disease Index (OSDI) questionnaires. Use of OTC dry eye medication, and satisfaction with OTC medication and symptom relief were also assessed. On average, dry eye resulted in loss of 0.36% of work time (∼5 minutes over 7 days) and ∼30% impairment of workplace performance (presenteeism), work productivity, and non-job-related activities. Presenteeism and productivity impairment scores showed significant correlation with OSDI total (r = 0.55) and symptom domain (r = 0.50) scores, but not with dry eye clinical signs. Activity impairment score showed stronger correlation with OSDI total (r = 0.61) and symptom domain (r = 0.53) scores than with clinical signs (r ≤ 0.20). Almost 75% of patients used OTC dry eye medication. Levels of patient satisfaction with OTC medication (64.2%) and symptom relief from OTC (37.3%) were unaffected by administration frequency (≥3 vs. ≤2 times daily). Dry eye causes negligible absenteeism, but markedly reduces workplace and non-job-related performances. Impairment of work performance is more closely linked to dry eye symptoms than to clinical signs. Patients' perceptions of OTC dry eye medication tend to be more positive than their perceptions of symptom relief.

  15. Strong low-pass filtering effects on water vapour flux measurements with closed-path eddy correlation systems

    DEFF Research Database (Denmark)

    Ibrom, Andreas; Dellwik, Ebba; Flyvbjerg, Henrik K.

    2007-01-01

    datasets for this substantial measurement error. In contrast to earlier studies, a large number of spectra and raw data have been used in the analysis to define the low-pass filtering characteristic of the EC system. This revealed that the cut-off frequency of the closed-path EC system for water vapour......Turbulent water vapour fluxes measured with closed-path eddy correlation (EC) systems are unintentionally low-pass filtered by the system in a manner that varies with environmental conditions. Why and how is described here. So is the practical method that systematically corrects long-term flux...... concentration measurements decreases exponentially with increasing relative humidity. After correction for this unintended filtering, the fluxes are consistent with CO2 and H2O fluxes that were measured with an open-path sensor at the same time. The correction of water vapour flux measurements over a Beech...

  16. Special Issue: Selected papers from ECS'97

    DEFF Research Database (Denmark)

    1999-01-01

    This Special Issue of Analog Integrated Circuits and Signal Processing presents extended versions of selected papers from the First Electronic Circuits and Systems Conference (ECS'97) which was held on September 4-5, 1997, in Bratislava, Slovakia.......This Special Issue of Analog Integrated Circuits and Signal Processing presents extended versions of selected papers from the First Electronic Circuits and Systems Conference (ECS'97) which was held on September 4-5, 1997, in Bratislava, Slovakia....

  17. Factors influencing arsenic and nitrate removal from drinking water in a continuous flow electrocoagulation (EC) process

    International Nuclear Information System (INIS)

    Kumar, N. Sanjeev; Goel, Sudha

    2010-01-01

    An experimental study was conducted under continuous flow conditions to evaluate some of the factors influencing contaminant removal by electrocoagulation (EC). A bench-scale simulation of drinking water treatment was done by adding a filtration column after a rectangular EC reactor. Contaminant removal efficiency was determined for voltages ranging from 10 to 25 V and a comparative study was done with distilled water and tap water for two contaminants: nitrate and arsenic(V). Maximum removal efficiency was 84% for nitrate at 25 V and 75% for arsenic(V) at 20 V. No significant difference in contaminant removal was observed in tap water versus distilled water. Increase in initial As(V) concentration from 1 ppm to 2 ppm resulted in a 10% increase in removal efficiency. Turbidity in the EC reactor effluent was 52 NTU and had to be filtered to achieve acceptable levels of final turbidity (5 NTU) at steady-state. The flow regime in the continuous flow reactor was also evaluated in a tracer study to determine whether it is a plug flow reactor (PFR) or constantly stirred tank reactor (CSTR) and the results show that this reactor was close to an ideal CSTR, i.e., it was fairly well-mixed.

  18. Factors influencing arsenic and nitrate removal from drinking water in a continuous flow electrocoagulation (EC) process

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, N. Sanjeev [Civil Engineering Department, IIT Kharagpur, Kharagpur 721302 (India); Goel, Sudha, E-mail: sudhagoel@civil.iitkgp.ernet.in [Civil Engineering Department, IIT Kharagpur, Kharagpur 721302 (India)

    2010-01-15

    An experimental study was conducted under continuous flow conditions to evaluate some of the factors influencing contaminant removal by electrocoagulation (EC). A bench-scale simulation of drinking water treatment was done by adding a filtration column after a rectangular EC reactor. Contaminant removal efficiency was determined for voltages ranging from 10 to 25 V and a comparative study was done with distilled water and tap water for two contaminants: nitrate and arsenic(V). Maximum removal efficiency was 84% for nitrate at 25 V and 75% for arsenic(V) at 20 V. No significant difference in contaminant removal was observed in tap water versus distilled water. Increase in initial As(V) concentration from 1 ppm to 2 ppm resulted in a 10% increase in removal efficiency. Turbidity in the EC reactor effluent was 52 NTU and had to be filtered to achieve acceptable levels of final turbidity (5 NTU) at steady-state. The flow regime in the continuous flow reactor was also evaluated in a tracer study to determine whether it is a plug flow reactor (PFR) or constantly stirred tank reactor (CSTR) and the results show that this reactor was close to an ideal CSTR, i.e., it was fairly well-mixed.

  19. EC6 design features and pre-project licensing review

    Energy Technology Data Exchange (ETDEWEB)

    Yu, S.; Lee, A.G.; Dinh, N.B.; Soulard, M. [CANDU Energy Inc., Mississauga, Ontario, (Canada)

    2013-07-01

    The Enhanced CANDU 6 (EC6) is the new Generation III CANDU reactor design that meets the most up to date Canadian regulatory requirements and customer expectations. Candu Energy Inc. is finalizing development of the EC6 which incorporates the CANDU 6's well-proven features, and adds enhancements that strengthened reactor safety margin and improved operability. The EC6 builds on the proven high performance design and the defence-in-depth features of CANDU 6 units, and has incorporated extensive operational feedback including lessons learned from Fukushima. This paper will provide status of the engineering program including progress on the pre-licensing review of the EC6 design by the Canadian Regulator, CNSC, and will also highlight the design and safety enhancements incorporated in the EC6 product. Safety enhancements to meet safety goals and to improve robustness of systems to respond to design basis accidents and beyond design basis accidents include: new severe accident recovery and heat removal system; improved emergency heat removal system; faster shutoff rods with improved safety margins; mechanical guaranteed shutdown rods; daily load cycling capability; robust containment with containment filter venting system; and improved backed-up electrical supply and cooling services. (author)

  20. Do Decision 2003/54/EC and Decision no. 1229/2003/EC result in a European market for electricity?

    International Nuclear Information System (INIS)

    Wenting, F.

    2004-01-01

    In the summer of 2003 the European Parliament and the European Council issued a new Directive with respect to the internal market for electricity (Directive 2003/54/EC of the European Parliament and of the Council of 26 June 2003 concerning common rules for the internal market in electricity) and Guidelines for trans-European networks in the energy sector (Decision no. 1229/2003/EC). The question is whether these decisions will lead to a European and free market for electricity. It is concluded that this is not yet the case [nl

  1. Seizure threshold to lidocaine is decreased following repeated ECS (electroconvulsive shock)

    DEFF Research Database (Denmark)

    Kragh, J; Seidelin, J; Bolwig, T G

    1993-01-01

    Seizure susceptibility to lidocaine was investigated in rats which had received repeated ECS (electroconvulsive shock). In the first experiment three groups of rats received an ECS daily for 18 days, an ECS weekly for 18 weeks, and 18 sham treatments, respectively. Twelve weeks after the last ECS...... all rats received a lidocaine challenge (LC) in the form of an intraperitoneal (IP) injection of lidocaine (65 mg/kg). After the injection the animals were observed for occurrence of motor seizures. A total of 67% (10/15), 47% (7/15), and 0% (0/18) of the daily, weekly, and sham groups, respectively......, had motor seizures in response to the LC. In the second experiment five groups of rats received an ECS daily for 0, 1, 6, 18, and 36 days, respectively. Eighteen weeks after the last ECS all rats received an LC and 0% (0/15), 13% (2/15), 20% (3/15), 53% (8/15), and 58% (7/12), respectively, developed...

  2. Eye Closure Reduces the Cross-Modal Memory Impairment Caused by Auditory Distraction

    Science.gov (United States)

    Perfect, Timothy J.; Andrade, Jackie; Eagan, Irene

    2011-01-01

    Eyewitnesses instructed to close their eyes during retrieval recall more correct and fewer incorrect visual and auditory details. This study tested whether eye closure causes these effects through a reduction in environmental distraction. Sixty participants watched a staged event before verbally answering questions about it in the presence of…

  3. Ketone EC50 values in the Microtox test.

    Science.gov (United States)

    Chen, H F; Hee, S S

    1995-03-01

    The Microtox EC50 values for the following ketones are reported in the following homologous series: straight chain methyl ketones (acetone, 2-butanone, 2-pentanone, 2-hepatonone, 2-octanone, 2-decanone, and 2-tridecanone); methyl ketones substituted at one alpha carbon (3-methyl-2-butanone; 3,3-dimethyl-2-butanone); methyl substituted at two alpha carbons (2,4-dimethyl-3-pentanone; 2,2,4,4-tetramethyl-3-pentanone); phenyl groups replacing methyl in acetone (acetophenone; benzophenone); methyl groups substituted at the alpha carbons of cyclohexanone; and 2,3- 2,4-, and 2,5-hexanediones, most for the first time. While there were linear relationships between log EC50 and MW for the straight chain methyl ketones, and for methyl substitution at the alpha carbon for methyl ketones, there were no other linear relationships. As molecular weight increased, the EC50 values of soluble ketones decreased; as distance between two carbonyl groups decreased so too did EC50 values. Thus, for the ketones the geometry around the carbonyl group is an important determinant of toxicity as well as MW, water solubility, and octanol/water coefficient.

  4. 78 FR 59944 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2013-09-30

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30, Research Triangle Park, NC 27709, (919... [[Page 59945

  5. Blue eyes in lemurs and humans: same phenotype, different genetic mechanism

    DEFF Research Database (Denmark)

    Bradley, Brenda J; Pedersen, Anja; Mundy, Nicholas I

    2009-01-01

    Almost all mammals have brown or darkly-pigmented eyes (irises), but among primates, there are some prominent blue-eyed exceptions. The blue eyes of some humans and lemurs are a striking example of convergent evolution of a rare phenotype on distant branches of the primate tree. Recent work...... on humans indicates that blue eye color is associated with, and likely caused by, a single nucleotide polymorphism (rs12913832) in an intron of the gene HERC2, which likely regulates expression of the neighboring pigmentation gene OCA2. This raises the immediate question of whether blue eyes in lemurs might...... have a similar genetic basis. We addressed this by sequencing the homologous genetic region in the blue-eyed black lemur (Eulemur macaco flavifrons; N = 4) and the closely-related black lemur (Eulemur macaco macaco; N = 4), which has brown eyes. We then compared a 166-bp segment corresponding...

  6. Perceptions of eye health in schools in Pakistan

    Directory of Open Access Journals (Sweden)

    Qureshi Mohammad

    2006-03-01

    Full Text Available Abstract Background Research exploring children's and their teachers' perceptions of eye health is lacking. This paper reports for the first time on perceptions of primary schoolchildren and their teachers of healthy and diseased eyes, things that keep eyes healthy and damage them, and what actions to be taken in case of an eye injury. Methods Using draw and write technique, 160 boys and girls (9–12 years old attending four primary schools in Abbottabad district, northern Pakistan, were invited to draw pictures in response to a set of semi-structured questions and then label them. Sixteen teachers who were currently teaching the selected students were interviewed one-on-one. Results Analysis of text accompanying 800 drawings and of the interview scripts revealed that most children and teachers perceived healthy eyes to be those which could see well, and diseased eyes to be those which have redness, watering, dirty discharge, pain, and itching; or those which have "weak eyesight" and blindness. Among things that students and teachers thought damage the eyes included sun, television, and sharp pointed objects, particularly pencils. Teachers noted that children with eye problems "have difficulty seeing the blackboard well", "screw up their eyes", and "hold their books too close". Conclusion We conclude that schoolchildren and their teachers had a good knowledge of eye health, but many of them had serious misconceptions e.g., use of kohl, medicines and eye drops keeps eyes healthy. Kohl is an important source of lead and can reduce children's intelligence even at low blood levels. Health education in schools must take into account children's existing knowledge of and misconceptions about various aspects of eye health. Such steps if taken could improve the relevance of eye health education to schoolchildren.

  7. Ultrathin flexible piezoelectric sensors for monitoring eye fatigue

    Science.gov (United States)

    Lü, Chaofeng; Wu, Shuang; Lu, Bingwei; Zhang, Yangyang; Du, Yangkun; Feng, Xue

    2018-02-01

    Eye fatigue is a symptom induced by long-term work of both eyes and brains. Without proper treatment, eye fatigue may incur serious problems. Current studies on detecting eye fatigue mainly focus on computer vision detect technology which can be very unreliable due to occasional bad visual conditions. As a solution, we proposed a wearable conformal in vivo eye fatigue monitoring sensor that contains an array of piezoelectric nanoribbons integrated on an ultrathin flexible substrate. By detecting strains on the skin of eyelid, the sensors may collect information about eye blinking, and, therefore, reveal human’s fatigue state. We first report the design and fabrication of the piezoelectric sensor and experimental characterization of voltage responses of the piezoelectric sensors. Under bending stress, the output voltage curves yield key information about the motion of human eyelid. We also develop a theoretical model to reveal the underlying mechanism of detecting eyelid motion. Both mechanical load test and in vivo test are conducted to convince the working performance of the sensors. With satisfied durability and high sensitivity, this sensor may efficiently detect abnormal eyelid motions, such as overlong closure, high blinking frequency, low closing speed and weak gazing strength, and may hopefully provide feedback for assessing eye fatigue in time so that unexpected situations can be prevented.

  8. A tropical horde of counterfeit predator eyes.

    Science.gov (United States)

    Janzen, Daniel H; Hallwachs, Winnie; Burns, John M

    2010-06-29

    We propose that the many different, but essentially similar, eye-like and face-like color patterns displayed by hundreds of species of tropical caterpillars and pupae-26 examples of which are displayed here from the dry, cloud, and rain forests of Area de Conservacion Guanacaste (ACG) in northwestern Costa Rica-constitute a huge and pervasive mimicry complex that is evolutionarily generated and sustained by the survival behavior of a large and multispecific array of potential predators: the insect-eating birds. We propose that these predators are variously and innately programmed to flee when abruptly confronted, at close range, with what appears to be an eye of one of their predators. Such a mimetic complex differs from various classical Batesian and Müllerian mimicry complexes of adult butterflies in that (i) the predators sustain it for the most part by innate traits rather than by avoidance behavior learned through disagreeable experiences, (ii) the more or less harmless, sessile, and largely edible mimics vastly outnumber the models, and (iii) there is no particular selection for the eye-like color pattern to closely mimic the eye or face of any particular predator of the insect-eating birds or that of any other member of this mimicry complex. Indeed, selection may not favor exact resemblance among these mimics at all. Such convergence through selection could create a superabundance of one particular false eyespot or face pattern, thereby increasing the likelihood of a bird species or guild learning to associate that pattern with harmless prey.

  9. Molecular Diagnosis of Human Taenia martis Eye Infection.

    Science.gov (United States)

    Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis

    2016-05-04

    Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. © The American Society of Tropical Medicine and Hygiene.

  10. A γA-Crystallin Mouse Mutant Secc with Small Eye, Cataract and Closed Eyelid.

    Directory of Open Access Journals (Sweden)

    Man Hei Cheng

    Full Text Available Cataract is the most common cause of visual loss in humans. A spontaneously occurred, autosomal dominant mouse mutant Secc, which displayed combined features of small eye, cataract and closed eyelid was discovered in our laboratory. In this study, we identified the mutation and characterized the cataract phenotype of this novel Secc mutant. The Secc mutant mice have eyelids that remain half-closed throughout their life. The mutant lens has a significant reduction in size and with opaque spots clustered in the centre. Histological analysis showed that in the core region of the mutant lens, the fiber cells were disorganized and clefts and vacuoles were observed. The cataract phenotype was evident from new born stage. We identified the Secc mutation by linkage analysis using whole genome microsatellite markers and SNP markers. The Secc locus was mapped at chromosome 1 flanked by SNPs rs3158129 and rs13475900. Based on the chromosomal position, the candidate cataract locus γ-crystallin gene cluster (Cryg was investigated by sequencing. A single base deletion (299delG in exon 3 of Cryga which led to a frame-shift of amino acid sequence from position 91 was identified. As a result of this mutation, the sequences of the 3rd and 4th Greek-key motifs of the γA-crystallin are replaced with an unrelated C-terminal peptide of 75 residues long. Coincidentally, the point mutation generated a HindIII restriction site, allowing the identification of the CrygaSecc mutant allele by RFLP. Western blot analysis of 3-week old lenses showed that the expression of γ-crystallins was reduced in the CrygaSecc mutant. Furthermore, in cell transfection assays using CrygaSecc mutant cDNA expression constructs in 293T, COS-7 and human lens epithelial B3 cell lines, the mutant γA-crystallins were enriched in the insoluble fractions and appeared as insoluble aggregates in the transfected cells. In conclusion, we have demonstrated that the Secc mutation leads to the

  11. Saccadic Eye Movement Improves Plantar Sensation and Postural Balance in Elderly Women.

    Science.gov (United States)

    Bae, Youngsook

    2016-06-01

    Vision, proprioception and plantar sensation contribute to the control of postural balance (PB). Reduced plantar sensation alters postural response and is at an increased risk of fall, and eye movements reduce the postural sway. Therefore, the aim of this study was to study the improvement of plantar sensation and PB after saccadic eye movement (SEM) and pursuit eye movement (PEM) in community-dwelling elderly women. Participants (104 females; 75.11 ± 6.25 years) were randomly allocated into the SEM group (n = 52) and PEM groups (n = 52). The SEM group performed eye fixation and SEM for 5 minutes, and the PEM group performed eye fixation and PEM for 5 minutes. The plantar sensation was measured according to the plantar surface area of the feet in contact with the floor surface before and after the intervention. Before and after SEM and PEM with the eyes open and closed, PB was measured as the area (mm(2)), length (cm), and velocity (cm/s) of the fluctuation of the center of pressure (COP). The plantar sensation of both feet improved in both groups (p eye open and close in both groups (p < 0.01). The length and velocity of the COP significantly decreased in the SEM group compared to the PEM group (p < 0.05). In conclusion, SEM and PEM are effective interventions for improving plantar sensation and PB in elderly women, with greater PB improvement after SEM.

  12. Eye cosmetic usage and associated ocular comfort.

    Science.gov (United States)

    Ng, Alison; Evans, Katharine; North, Rachel; Purslow, Christine

    2012-11-01

    Eye cosmetics usage is commonplace and whilst some products such as eyeliner are applied with close proximity to the ocular surface, there is little knowledge of the short- and long-term ocular effects of eye cosmetic formulations. This study aimed to investigate the use of eye cosmetics and identify any relationships between ocular comfort and cosmetic usage. Results were collated from an online survey comprising 23 questions that recorded demographics, Ocular Surface Disease Index (OSDI) score, extent and range of eye cosmetic use and perceived comfort differences with and without eye cosmetics. The 1360 female respondents (median age 25, interquartile range 20-34 years) completed the survey; 83% reported using eye cosmetics regularly (≥ 3 times per week) with mascara being most commonly used. Fifty three per cent used at least three different eye cosmetics products regularly. OSDI scores of cosmetics users were similar to non-users (p = 0.083), but perceived comfort was greater when cosmetics were not used (p cosmetics users (use of products cosmetics were used. Median OSDI scores suggested a trend towards reduced comfort amongst eyeliner users (p = 0.07) although frequency and type of cosmetic products used did not appear to influence OSDI scores. This study shows the use of multiple eye cosmetics is extensive and associated with the perception of ocular discomfort. With such widespread use of these products, more research is required to assess the effect on the ocular surface and tear film, which may be underestimated. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

  13. and alanine (EC. 2.6.1.2) transaminases, and alkaline phosphatase

    African Journals Online (AJOL)

    The activities of aspartate (E.C. 2.6.1.1) and alanine (E.C. 2.6.1.2) transaminases (AST and ALT, respectively), and alkaline phosphatase (ALP) (E.C. 3.1.3.1) were determined in erythrocytes obtained from 20 HbAA, 15 HbAS and 12 HbSS human subjects. The results showed that the three enzymes had different levels of ...

  14. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  15. Energy conservation in the EC glass industry

    Energy Technology Data Exchange (ETDEWEB)

    Waal, H. de [TNO Institute of Applied Physics, Delft (Netherlands)

    1994-12-31

    The data presented in this survey are based mainly on a recent study, performed by the Energy Technology Support Unit ETSU. Harwell Laboratory, United Kingdom, in the context of the EC-Thermie programme. Also, use has been made of a paper `Glass Manufacture, energy and CO{sub 2}-emissions`, presented by G.J. Copley of the British Glass Manufacturers Confederation, Sheffield, United Kingdom, presented at the Thermie Seminar in Wiesbaden, 1992. A third source of information has been the data collected by the CPIV, the European Glass Manufacturers Federation on the present and future economic situation of the EC Glass Industry. (orig.)

  16. PREVALENCE OF FOVEOLAR LUCENCY WITH DIFFERENT GAS TAMPONADES IN SURGICALLY CLOSED MACULAR HOLES ASSESSED BY SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY.

    Science.gov (United States)

    Zarranz-Ventura, Javier; Ellabban, Abdallah A; Sim, Dawn A; Keane, Pearse A; Kirkpatrick, James N; Sallam, Ahmed A B

    2017-07-07

    To evaluate the prevalence of foveolar lucency (FL) in surgically closed macular holes by spectral domain optical coherence tomography. One hundred forty-two eyes of 132 patients underwent pars plana vitrectomy, internal limiting membrane peeling, and gas tamponade in a 60-month time frame. Anatomical success and FL rates assessed by spectral domain optical coherence tomography, mean preoperative, and postoperative best-measured visual acuity and surgical details were retrospectively analyzed. Spectral domain optical coherence tomography confirmed closed holes with FL in 33.7% (34/101) of eyes at 1 month, 7.3% (9/123) at 3 months, 4.6% (6/129) at 6 months, and 3% (4/133) at 12 months. Prevalence of FL in closed holes at Month 1 was lower in C3F8-treated eyes (9.5%, 2/21) compared with C2F6 (40.9%, 18/44, P = 0.03) and SF6-treated eyes (38.9%, 14/36, P = 0.05). No differences were observed at Month 3. No differences in best-measured visual acuity change were observed between closed holes with or without FL at Month 1 (-0.14 ± 0.19 vs. -0.11 ± 0.23, P = 0.48) or any of the other time points. Temporary FL is a highly prevalent feature in successfully closed macular holes. Eyes treated with C3F8 gas had lower rates of FL at Month 1 than C2F6 and SF6-treated eyes. The presence of FL in closed holes does not seem to have any effect on the visual outcomes.

  17. Canada files WTO complaint against EC.

    Science.gov (United States)

    2000-01-01

    In December 1998, Canada filed a complaint alleging that the European Communities (EC) had adopted regulations that amounted to a scheme to extend patent terms, limited to pharmaceutical and agricultural chemical products.

  18. NASA FACTS: E. coli AntiMicrobial Satellite (EcAMSat)

    Science.gov (United States)

    Spremo, Stevan; Cappuccio, Gelsomina; Tomko, David

    2013-01-01

    The E. coli AntiMicrobial Satellite(EcAMSat) mission will investigate space microgravity affects on the antibiotic resistance of E. coli, a bacterial pathogen responsible for urinary tract infection in humans and animals. EcAMSat is being developed through a partnership between NASAs Ames Research Center and the Stanford University School of Medicine. Dr. A.C. Matin is the Stanford University Principal Investigator. EcAMSat will investigate spaceflight effects on bacterial antibiotic resistance and its genetic basis. Bacterial antibiotic resistance may pose a danger to astronauts in microgravity, where the immune response is weakened. Scientists believe that the results of this experiment could help design effective countermeasures to protect astronauts health during long duration human space missions.

  19. Scanning laser polarimetry in eyes with exfoliation syndrome.

    Science.gov (United States)

    Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P

    2013-01-01

    To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes.
 Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. 
 The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), ppolarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.

  20. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    Science.gov (United States)

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  1. Accelerator-Driven Systems - the iThEC strategy

    International Nuclear Information System (INIS)

    Revol, Jean-Pierre

    2015-01-01

    The International Thorium Energy Committee (iThEC) created in Geneva in 2012 is concerned about the energetic future of our society, which is totally organized on the basis of a fossil fuel economy. This has to change because of obvious geopolitical reasons, because of the impact this economy has on the environment, and because of the rather short time on the human time scale, it will take for fossil fuels to run out. One of the main goals of iThEC is to work on reversing the current negative perception of nuclear energy in Europe, which is the main hurdle to a more serious R and D effort in this field. iThEC provides better information to the public on thorium possibilities, supports thorium ADS technology developments, any R and D regarding thorium, and actively engages the scientific, political and business leadership on the subject

  2. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  3. Effect of Dursban 480 EC (chlorpyrifos) and Talstar 10 EC (bifenthrin) on the physiological and genetic diversity of microorganisms in soil.

    Science.gov (United States)

    Medo, Juraj; Maková, Jana; Kovácsová, Silvia; Majerčíková, Kamila; Javoreková, Soňa

    2015-01-01

    This investigation was undertaken to determine the impact of the insecticides Dursban 480 EC (with organophosphate compound chlorpyrifos as the active ingredient) and Talstar 10 EC (with pyrethroid bifenthrin as the active ingredient) on the respiration activity and microbial diversity in a sandy loam luvisol soil. The insecticides were applied in two doses: the maximum recommended dose for field application (15 mg kg(-1) for Dursban 480 EC and 6 mg kg(-1) for Talstar 10 EC) and a 100-fold higher dose for extrapolation of their effect. Bacterial and fungal genetic diversity was analysed in soil samples using PCR DGGE and the functional diversity (catabolic potential) was studied using BIOLOG EcoPlates at 1, 3, 7, 14, 28, 56 and 112 days after insecticide application. Five bacterial groups (α, β, γ proteobacteria, firmibacteria and actinomycetes) and five groups of fungi or fungus-like microorganisms (Ascomycota, Basidiomycota, Chytridiomycota, Oomycota and Zygomycota) were analysed using specific primer sets. This approach provides high resolution of the analysis covering majority of microorganisms in the soil. Only the high-dose Dursban 480 EC significantly changed the community of microorganisms. We observed its negative effect on α- and γ-proteobacteria, as the number of OTUs (operational taxonomic units) decreased until the end of incubation. In the β-proteobacteria group, initial increase of OTUs was followed by strong decrease. Diversity in the firmibacteria, actinomycetes and Zygomycota groups was minimally disturbed by the insecticide application. Dursban 480 EC, however, both positively and negatively affected certain species. Among negatively affected species Sphingomonas, Flavobacterium or Penicillium were detected, but Achromobacter, Luteibacter or Aspergillus were supported by applied insecticide. The analysis of BIOLOG plates using AWCD values indicated a significant increase in metabolic potential of microorganisms in the soil after the high

  4. Accommodation, refractive error and eye growth in chickens.

    Science.gov (United States)

    Schaeffel, F; Glasser, A; Howland, H C

    1988-01-01

    We raised chickens with defocusing lenses of differing powers in front of their eyes. For this purpose, small hoods made from soft, thin leather were carefully fitted to their heads. Lenses were attached to the hoods by velcro fasteners and could be easily removed for cleaning. The powers of the lenses were such that their optical effects could be compensated for by accommodation. It was verified by infrared (IR) photoretinoscopy that the chickens could keep their retinal images in focus. Wearing a lens resulted in a consistent shift of the non cycloplegic refractive state (measured without the lens) which was in the direction to compensate for the lens. We used a sensitive technique (precision = +/- 50 micron as estimated from the variability of repeated measurements) to measure the posterior nodal distance (PND) in excised eyes of birds grown with lenses. The PND, in turn, was used to compare eyes treated with different lenses. It was found that the PND was increased in eyes which were treated with negative lenses compared to those treated with positive lenses. This effect occurs independently in both eyes and it is not due to changes in corneal curvature. We discuss our result in terms of a closed-loop feedback system for the regulation of eye growth.

  5. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  6. Nuclear power in the EC

    International Nuclear Information System (INIS)

    Charrault, J.C.

    1991-01-01

    Nuclear power accounts for some 35% of electricity production in the European Community (EC). Using a mathematical analysis, based on different scenarios, i.e. low/high electricity demand and nuclear moratorium/revival, various demand forecasts are made. A pragmatic approach, considering conventional power generation pollution problems, forecasts a revival of nuclear power

  7. A CASE OF SELF-INDUCED ACUTE HYDROPS IN A PATIENT WITH IMPULSE CONTROL DISORDER ASSOCIATED WITH COMPULSIVE EYE TRAUMA

    Directory of Open Access Journals (Sweden)

    Bindu Madhavi

    2016-03-01

    Full Text Available PURPOSE To describe acute hydrops in a patient with impulse control disorder (not otherwise specified secondary to self-induced repetitive eye trauma. METHODS A 22-year-old male patient was referred from a psychiatrist with a diagnosis of impulse control disorder not otherwise specified (compulsive impulse self-mutilating behaviour for opacity and watering of both eyes (left eye more than right eye. Left eye showed features of acute hydrops with Descemet’s tear and right eye showed corneal opacity with Descemet’s tear (status post hydrops. RESULT The patient was prescribed cycloplegics, hypertonic saline for left eye and was advised against scratching the eye and was given protective goggles and was told for close followup in conjunction with psychiatric management. CONCLUSION Impulse control disorders are relatively common psychiatric conditions, yet are poorly understood by clinicians, patients suffering from the disorder and public. And hence identification of this disorder and close observation of patient allows for avoiding complications such as progression of hydrops, perforation and infection.

  8. Mathematical modeling improves EC50 estimations from classical dose-response curves.

    Science.gov (United States)

    Nyman, Elin; Lindgren, Isa; Lövfors, William; Lundengård, Karin; Cervin, Ida; Sjöström, Theresia Arbring; Altimiras, Jordi; Cedersund, Gunnar

    2015-03-01

    The β-adrenergic response is impaired in failing hearts. When studying β-adrenergic function in vitro, the half-maximal effective concentration (EC50 ) is an important measure of ligand response. We previously measured the in vitro contraction force response of chicken heart tissue to increasing concentrations of adrenaline, and observed a decreasing response at high concentrations. The classical interpretation of such data is to assume a maximal response before the decrease, and to fit a sigmoid curve to the remaining data to determine EC50 . Instead, we have applied a mathematical modeling approach to interpret the full dose-response curve in a new way. The developed model predicts a non-steady-state caused by a short resting time between increased concentrations of agonist, which affect the dose-response characterization. Therefore, an improved estimate of EC50 may be calculated using steady-state simulations of the model. The model-based estimation of EC50 is further refined using additional time-resolved data to decrease the uncertainty of the prediction. The resulting model-based EC50 (180-525 nm) is higher than the classically interpreted EC50 (46-191 nm). Mathematical modeling thus makes it possible to re-interpret previously obtained datasets, and to make accurate estimates of EC50 even when steady-state measurements are not experimentally feasible. The mathematical models described here have been submitted to the JWS Online Cellular Systems Modelling Database, and may be accessed at http://jjj.bio.vu.nl/database/nyman. © 2015 FEBS.

  9. ST ECS error handling and detector safety

    CERN Document Server

    Esperante Pereira, D

    2010-01-01

    This note describes the automatic operation sequences that the ECS implements in order to operate the ST detector in a safe and reliable way. First, the start-up sequences to set the detector in a well known state are described. In addition the possible ST detector states based on the status of the different detector elements will be defined. The states are of crucial interest for the safe operation of the detector when the LHC beam is ready. Besides, the ECS automatic actions taken in case of abnormal status of any of the detector elements are reported. Next, the operational alarm ranges and the error recovery mechanisms are mentioned.

  10. EC Transmission Line Risk Identification and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bigelow, Tim S [ORNL

    2012-04-01

    The purpose of this document is to assist in evaluating and planning for the cost, schedule, and technical project risks associated with the delivery and operation of the EC (Electron cyclotron) transmission line system. In general, the major risks that are anticipated to be encountered during the project delivery phase associated with the implementation of the Procurement Arrangement for the EC transmission line system are associated with: (1) Undefined or changing requirements (e.g., functional or regulatory requirements) (2) Underperformance of prototype, first unit, or production components during testing (3) Unavailability of qualified vendors for critical components Technical risks associated with the design and operation of the system are also identified.

  11. EC interior energy market - legal bases and implications for the Austrian electricity industry

    International Nuclear Information System (INIS)

    Fremuth, W.

    1989-01-01

    The author begins by outlining what 'internal energy market' means and Austria's relationship to it and to the EC and describes the present state of cooperation in electricity supply between European countries. He discusses amongst other things: distortions to competition, cost structures, responsibility for a Europe-wide network, the effects of setting up a central European load distributor on Austria's electricity industry, the economic consequences of the common-carrier in Austria, monopolies and exclusive rights, cross-border exchanges, reliability and quality of supply, and savings in costs. He hopes that efforts towards further integration in Europe do not upset the already close cooperation between supply networks by introducing unreal, counter-productive objectives. (T.J.R.A.)

  12. The EC6 - an enhanced mid-sized reactor with fuel cycle applications

    International Nuclear Information System (INIS)

    Soulard, M.; Yu, S.; Hopwood, J.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada Limited (AECL) has two CANDU reactor products matched to markets: the Enhanced CANDU 6 (EC6), a modern 700 MWe-class design, and the Advanced CANDU Reactor (ACR-1000), a 1200 MWe-class Gen III+ design. Both reactor types are designed to meet both market-, and customer-driven needs; the ACR-1000 design is 90% complete and market-ready. The EC6 incorporates the CANDU 6's well-proven features, and adds enhancements that make the reactor even safer and easier to operate. The EC6 is the only mid-sized reactor with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. The EC6 has domestic and offshore market pull and is the current focus of AECL's development program; market interest in the ACR-1000 is anticipated in the longer term. Some of the key features incorporated into the EC6 include upgrading containment and seismic capability to meet modern standards, shortening the overall project schedule, addressing obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the operating plants. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. The first deployment of the EC6 is anticipated in Canada; off-shore markets are also being pursued. The EC6 burns natural uranium as standard. But, high neutron economy, on-power refuelling, a simple fuel bundle, and the fundamental CANDU fuel channel design provide the EC6 with the flexibility to accommodate a range of advanced fuels. (author)

  13. 78 FR 39739 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2013-07-02

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... clearly unwarranted invasion of personal privacy. Name of Committee: Environmental Health Sciences Review... Research and Training, National Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30...

  14. 78 FR 14312 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2013-03-05

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory... Health Sciences Special Emphasis Panel; Understanding Environmental Control of Epigenetic/Mechanisms... Extramural Research and Training, Nat. Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30...

  15. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    Science.gov (United States)

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  16. Utilizing an eye tracker device for operator support

    NARCIS (Netherlands)

    Greef, T.E. de; Lafeber, H.

    2007-01-01

    At present a number of studies have attempted to embed eye-tracking devices into closed-loop systems to augment the cognitive state of the human operator. It has been demonstrated that the pupil diameter and blinking frequency serve as such indicators. Although these two factors serve cognitive

  17. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  18. Internal structure changes of eyelash induced by eye makeup.

    Science.gov (United States)

    Fukami, Ken-Ichi; Inoue, Takafumi; Kawai, Tomomitsu; Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2014-01-01

    To investigate how eye makeup affects eyelash structure, internal structure of eyelashes were observed with a scanning X-ray microscopic tomography system using synchrotron radiation light source. Eyelash samples were obtained from 36 Japanese women aged 20-70 years and whose use of eye makeup differed. Reconstructed cross-sectional images showed that the structure of the eyelash closely resembled that of scalp hair. The eyelash structure is changed by use of eye makeup. There was a positive correlation between the frequency of mascara use and the degree of cracking in cuticle. The positive correlation was also found between the frequency of mascara use and the porosity of the cortex. By contrast, the use of eyelash curler did not affect the eyelash structure with statistical significance.

  19. Lymphocyte adhesion to endothelial cell (EC) is stimulated by phorbol esters

    International Nuclear Information System (INIS)

    Haskard, D.; Cavender, D.; Ziff, M.

    1986-01-01

    The effect of phorbol esters on T cell adhesion to EC has been studied. The phorbol esters 12-0-tetradecanoyl-phorbol-13-acetate and 4-beta-phorbol-12-13-dibutyrate, but not the biologically inert 4-0-methyl-phorbol-12-13-didecanoate strongly increased the binding of 51 Cr-labeled T cells to human umbilical vein EC monolayers in microtiter wells. Increase in binding was observed at 0.3 ng/ml with maximal enhancement at 50 ng/ml. Both unstimulated and phorbol ester activated T cells displayed a substantially greater binding affinity for EC than for fibroblasts or plastic. Binding enhancement occurred within one minute, with maximal increase after 15 min. Preincubation studies showed that binding enhancement was entirely attributable to an effect on T cells, with no action on EC. Additive binding enhancement was seen when phorbol esters and reagents that increase adhesion by actions on EC (LPS, IL-1 and IFN-γ) were used together. Increase in adhesion of activated T lymphocytes to EC may explain the greater emigration of activated T cells than small resting T cells into inflammatory foci in vivo. The rapid onset of the phorbol effect suggests that this may be an important mechanism for immediate localization of circulating T cells in the cellular immune response, activated, perhaps, at the endothelial blood-tissue interface

  20. On the practical exploitability of dual EC in TLS implementations

    NARCIS (Netherlands)

    Checkoway, S.; Fredrikson, M.; Niederhagen, R.F.; Everspaugh, A.; Green, M.; Lange, T.; Ristenpart, T.; Bernstein, D.J.; Maskiewicz, J,; Shacham, H.

    2014-01-01

    This paper analyzes the actual cost of attacking TLS implementations that use NIST’s Dual EC pseudorandom number generator, assuming that the attacker generated the constants used in Dual EC. It has been known for several years that an attacker generating these constants and seeing a long enough

  1. EC6 safety enhancement - including impact of Fukushima lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    Yu, S.; Zemdegs, R.; Boyle, S.; Soulard, M., E-mail: stephen.yu@candu.com [Candu Energy Inc., Mississauga, Ontario (Canada)

    2012-09-15

    The Enhanced CANDU 6 (EC6) is the new Generation III CANDU reactor design that meets the most up to date regulatory requirements and customer expectations. EC6 builds on the proven high performance design inch as the Qinshan CANDU 6 units and has made improvements to safety and operational performance, and has incorporated extensive operational feedback including Fukushima. The Fukushima Dai-ichi March 11, 2011 event has demonstrated the importance of defence-in-depth considerations for beyond-design basis events, including severe accidents. The EC6 design is based on the defence-in-depth principles and provides further design features that address the lessons learned from Fukushima. (author)

  2. Eye surface temperature detects stress response in budgerigars (Melopsittacus undulatus).

    Science.gov (United States)

    Ikkatai, Yuko; Watanabe, Shigeru

    2015-08-05

    Previous studies have suggested that stressors not only increase body core temperature but also body surface temperature in many animals. However, it remains unclear whether surface temperature could be used as an alternative to directly measure body core temperature, particularly in birds. We investigated whether surface temperature is perceived as a stress response in budgerigars. Budgerigars have been used as popular animal models to investigate various neural mechanisms such as visual perception, vocal learning, and imitation. Developing a new technique to understand the basic physiological mechanism would help neuroscience researchers. First, we found that cloacal temperature correlated with eye surface temperature. Second, eye surface temperature increased after handling stress. Our findings suggest that eye surface temperature is closely related to cloacal temperature and that the stress response can be measured by eye surface temperature in budgerigars.

  3. 78 FR 18359 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2013-03-26

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory... Training, Nat. Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30, Research Triangle Park... Environmental Health Sciences Special Emphasis Panel; Research Careers in Emerging Technologies. Date: April 30...

  4. 77 FR 60445 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2012-10-03

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory... Research and Training, National Institute of Environmental Health Science, P.O. Box 12233, MD EC-30/Room... Environmental Health Sciences Special Emphasis Panel; Support for Conferences and Scientific Meetings. Date...

  5. 77 FR 22793 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2012-04-17

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory.... Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30, Research Triangle Park, NC 27709, (919....D., Scientific Review Administrator, Nat. Institute of Environmental Health Sciences, Office of...

  6. 78 FR 8156 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2013-02-05

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... Environmental Health Sciences Special Emphasis Panel; Studies of Environmental Agents to Induce Immunotoxicity... Research and Training, Nat. Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30, Research...

  7. 77 FR 6569 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2012-02-08

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... Health Sciences, Special Emphasis Panel, Environmental Stem Cells Research. Date: February 29-March 2... of Environmental Health Sciences, P.O. Box 12233, MD EC-30, Research Triangle Park, NC 27709, (919...

  8. 76 FR 13650 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2011-03-14

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory... Training, Nat. Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30/Room 3171, Research... Environmental Health Sciences Special Emphasis Panel; Review of Educational Grants with an Environmental Health...

  9. 76 FR 62080 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2011-10-06

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... clearly unwarranted invasion of personal privacy. Name of Committee: Environmental Health Sciences Review... Extramural Research and Training, Nat'l Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30...

  10. 77 FR 40076 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2012-07-06

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... Environmental Health Sciences, P.O. Box 12233, MD EC-30 Research Triangle Park, NC 27709, (919) 541- 0752... Manpower Development in the Environmental Health Sciences; 93.113, Biological Response to Environmental...

  11. 77 FR 16844 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2012-03-22

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory.... Institute Environmental Health Sciences, P.O. Box 12233, MD EC-30, Research Triangle Park, NC 27709, (919) 541-1307, [email protected] . Name of Committee: National Institute of Environmental Health Sciences...

  12. 75 FR 10293 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2010-03-05

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory.... Institute Environmental Health Sciences, P. O. Box 12233, MD EC-30, Research Triangle Park, NC 27709, (919... Health Sciences; 93.113, Biological Response to Environmental Health Hazards; 93.114, Applied...

  13. Clinical features and prognosis of eyeball rupture: eye injury vitrectomy study.

    Science.gov (United States)

    Feng, Kang; Wang, Chang-guan; Hu, Yun-tao; Yao, Yi; Jiang, Yan-rong; Shen, Li-jun; Pang, Xiu-qin; Nie, Hong-ping; Ma, Zhi-zhong

    2015-01-01

    The objective of the study was to delineate clinical characteristics, surgical interventions, anatomic and visual outcomes of ruptured eye balls after trauma, and establish the prognostic indicators, which can assist clinicians in making correct surgical decisions during globe exploration for ruptured eyes. The study design used was a multicentre prospective cohort study, including six university-affiliated tertiary hospitals. We selected 242 cases of ruptured globe from the Eye Injury Vitrectomy Study database, until 31 December 2012. All selected cases underwent vitreoretinal surgery, enucleation or evisceration, and were followed up for at least 6 months. Age, visual acuity (VA) after injury, ocular trauma zone, time to surgery, corneal laceration, scleral wound, extrusion of iris or lens, ciliary body damage, intraocular haemorrhage, retinal detachment or defect, proliferative vitreoretinopathy (PVR) and choroidal damage were the predisposing factors evaluated by logistic regression models. We compared the pre-surgical indicators between cases of anatomically restored eyes with VA of 4/200 or better, or eyes with initial no light perception restored light perception or better, and cases of VA worse than 4/200, silicone oil-sustained eyes, phthisis or enucleation. Nearly 40% of cases with ruptured globe were anatomically restored through vitreoretinal surgery. The closed-funnel retinal detachment or extensive retinal loss (odds ratio [OR] = 3.38, P = 0.026), PVR-C (OR = 3.45, P = 0.008), and choroidal damage (OR = 4.20, P = 0.004) were correlated with poor outcomes. The closed-funnel retinal detachment or extensive retinal loss, PVR-C, and choroidal damage are the risk factors for unfavourable outcomes in globe ruptures. © 2015 Royal Australian and New Zealand College of Ophthalmologists.

  14. Xanthophylls and eye health of infants and adults.

    Science.gov (United States)

    Moukarzel, Adib A; Bejjani, Riad A; Fares, Florence N

    2009-01-01

    Lutein and zeaxanthin are the only carotenoids present in the eye. They cannot be synthesized de novo and are specifically concentrated in the macula. They appear to have at least two major functions: to filter out blue light and thus prevent ensuing damages to the eye and to act as antioxidants. Infants are particularly at risk from both blue light and oxidative damage to eye tissues. Lutein is present in human milk but is not currently added to infant formulas. Fortifying formulae with lutein in order to match more closely human milk might help protect the infant's sensitive eyes. In adults, the exact pathogenesis of age-related maculopathy remains unknown. Light damage, inflammation, and the disruption of cellular processes by oxidative stress may play an important role in the degenerative process. Manipulation of intake of xanthophylls has been shown to augment macular pigment, therefore it is thought that carotenoid dietary supplements could prevent, delay, or modify the course of age-related maculopathy. However, definite evidence of the effect of carotenoids, the optimal doses to use, and the supplementation duration are still under investigation.

  15. Administering an eye anaesthetic: principles, techniques, and complications

    Directory of Open Access Journals (Sweden)

    Ahmed Fahmi

    2008-03-01

    Full Text Available The trigeminal nerve carries the sensory innervation of the eye and adnexa in three divisions: ophthalmic, maxillary, and mandibular. The sensory fibres of the eye and adnexa are found in the ophthalmic division – with the exception of a portion of the sensory input from the lower lid, which is carried by the maxillary division. Blocking the sensory fibres provides anaesthesia so that no pain is felt.The motor supply of the extraocular muscles and levator palpebrae superioris is carried by the oculomotor (III, trochlear (IV, and abducens (VI nerves. Paralysing these muscles by blocking their motor supply provides akinesia so that the eye does not move during surgery.The motor supply of the orbicularis oculi, which is responsible for the gentle and forcible closure of the eye, is carried by the facial nerve (VII. Blocking these fibres will provide better surgical exposure. It also reduces the risk of forcing out the ocular contents if the patient tries to close his eyelids forcibly after the surgeon opens the globe.

  16. A spectroscopic survey of EC4, an extended cluster in Andromeda's halo

    Science.gov (United States)

    Collins, M. L. M.; Chapman, S. C.; Irwin, M.; Ibata, R.; Martin, N. F.; Ferguson, A. M. N.; Huxor, A.; Lewis, G. F.; Mackey, A. D.; McConnachie, A. W.; Tanvir, N.

    2009-07-01

    We present a spectroscopic survey of candidate red giant branch stars in the extended star cluster, EC4, discovered in the halo of M31 from our Canada-France-Hawaii Telescope/MegaCam survey, overlapping the tidal streams, Streams`Cp' and `Cr'. These observations used the DEep Imaging Multi-Object Spectrograph mounted on the Keck II telescope to obtain spectra around the CaII triplet region with ~1.3 Å resolution. Six stars lying on the red giant branch within two core radii of the centre of EC4 are found to have an average vr = -287.9+1.9-2.4kms-1 and σv,corr = 2.7+4.2-2.7kms-1, taking instrumental errors into account. The resulting mass-to-light ratio for EC4 is M/L = 6.7+15-6.7Msolar/Lsolar, a value that is consistent with a globular cluster within the 1σ errors we derive. From the summed spectra of our member stars, we find EC4 to be metal-poor, with [Fe/H] = -1.6 +/- 0.15. We discuss several formation and evolution scenarios which could account for our kinematic and metallicity constraints on EC4, and conclude that EC4 is most comparable with an extended globular cluster. We also compare the kinematics and metallicity of EC4 with Streams `Cp' and`Cr', and find that EC4 bears a striking resemblance to Stream`Cp' in terms of velocity, and that the two structures are identical in terms of both their spectroscopic and photometric metallicities. From this, we conclude that EC4 is likely related to Stream`Cp'. The data presented herein were obtained at the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W.M. Keck Foundation. E-mail: mlmc2@ast.cam.ac.uk

  17. 75 FR 45133 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2010-08-02

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory.... Institute of Environmental Health Science, P.O. Box 12233, MD EC-30/Room 3170 B, Research Triangle Park, NC... Manpower Development in the Environmental Health Sciences; 93.113, Biological Response to Environmental...

  18. 77 FR 61613 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2012-10-10

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory... Environmental Health Sciences, P. O. Box 12233, MD EC-30, Research Triangle Park, NC 27709, (919) 541-1307, [email protected] . Name of Committee: National Institute of Environmental Health Sciences Special Emphasis...

  19. 75 FR 68367 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2010-11-05

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... Research and Training, Nat. Institute of Environmental Health Science, P.O. Box 12233, MD EC-30/Room 3170 B... Sciences; 93.113, Biological Response to Environmental Health Hazards; 93.114, Applied Toxicological...

  20. 76 FR 26311 - National Institute of Environmental Health Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2011-05-06

    ... Environmental Health Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory.... Institute of Environmental Health Sciences, P.O. Box 12233, MD EC-30/Room 3171, Research Triangle Park, NC... and Education; 93.894, Resources and Manpower Development in the Environmental Health Sciences; 93.113...

  1. 77 FR 37423 - National Institute of Environmental Health Sciences; Notice of Closed Meetings

    Science.gov (United States)

    2012-06-21

    ... Environmental Health Sciences; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory..., [email protected] . Name of Committee: National Institute of Environmental Health Sciences Special... Research and Training, Nat. Institute of Environmental Health Science, P.O. Box 12233, MD EC-30/Room 3170 B...

  2. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life.

    Science.gov (United States)

    Rasmussen, Marie Louise Roed

    2010-12-01

    continuous sharp light or as moving dots. The most frequent triggers were darkness, closing of the eyes, fatigue and psychological stress. Fifty-four percent of the patients had visual hallucinations more than once a week. Ten patients were so visually disturbed that it interfered with their daily life. Approximately 23% of all EA experience phantom pain for several years after the surgery. Phantom pain was reported to be of three different qualities: (i) cutting, penetrating, gnawing or oppressive (n=19); (ii) radiating, zapping or shooting (n=8); (iii) superficial burning or stinging (n=5); or a mixture of these different pain qualities (n=7). The median intensity on a visual analogue scale, ranging from 0 to 100, was 36 [range: 1-89]. One-third of the patients experienced phantom pain every day. Chilliness, windy weather and psychological stress/fatigue were the most commonly reported triggers for pain. Factors associated with phantom pain were: ophthalmic pain before EA, the presence of implant and a patient reported high degree of conjunctival secretion. A common reason for EA is the presence of a painful blind eye. However, one third of these patients continue to have pain after the EA. Phantom sensations were present in 2% of the patients. The impact of an eye amputation is considerable. EA patients have poorer health related quality of life, poorer self-rated health and more perceived stress than does the general population. The largest differences in health related quality of life between the EA patients and the general population were related to role limitations due to emotional problems and mental health. Patients with the indication painful blind eye are having lower scores in all aspects of health related quality of life and perceived stress than patients with the indication neoplasm and trauma. The percentage of eye amputated which is divorced or separated was twice as high as in the general population. Furthermore, 25% retired or changed to part-time jobs due

  3. Hippocampal closed-loop modeling and implications for seizure stimulation design

    Science.gov (United States)

    Sandler, Roman A.; Song, Dong; Hampson, Robert E.; Deadwyler, Sam A.; Berger, Theodore W.; Marmarelis, Vasilis Z.

    2015-10-01

    Objective. Traditional hippocampal modeling has focused on the series of feedforward synapses known as the trisynaptic pathway. However, feedback connections from CA1 back to the hippocampus through the entorhinal cortex (EC) actually make the hippocampus a closed-loop system. By constructing a functional closed-loop model of the hippocampus, one may learn how both physiological and epileptic oscillations emerge and design efficient neurostimulation patterns to abate such oscillations. Approach. Point process input-output models where estimated from recorded rodent hippocampal data to describe the nonlinear dynamical transformation from CA3 → CA1, via the schaffer-collateral synapse, and CA1 → CA3 via the EC. Each Volterra-like subsystem was composed of linear dynamics (principal dynamic modes) followed by static nonlinearities. The two subsystems were then wired together to produce the full closed-loop model of the hippocampus. Main results. Closed-loop connectivity was found to be necessary for the emergence of theta resonances as seen in recorded data, thus validating the model. The model was then used to identify frequency parameters for the design of neurostimulation patterns to abate seizures. Significance. Deep-brain stimulation (DBS) is a new and promising therapy for intractable seizures. Currently, there is no efficient way to determine optimal frequency parameters for DBS, or even whether periodic or broadband stimuli are optimal. Data-based computational models have the potential to be used as a testbed for designing optimal DBS patterns for individual patients. However, in order for these models to be successful they must incorporate the complex closed-loop structure of the seizure focus. This study serves as a proof-of-concept of using such models to design efficient personalized DBS patterns for epilepsy.

  4. Acute toxicity of heavy metals to acetate-utilizing mixed cultures of sulfate-reducing bacteria: EC100 and EC50.

    Science.gov (United States)

    Utgikar, V P; Chen, B Y; Chaudhary, N; Tabak, H H; Haines, J R; Govind, R

    2001-12-01

    Acid mine drainage from abandoned mines and acid mine pit lakes is an important environmental concern and usually contains appreciable concentrations of heavy metals. Because sulfate-reducing bacteria (SRB) are involved in the treatment of acid mine drainage, knowledge of acute metal toxicity levels for SRB is essential for the proper functioning of the treatment system for acid mine drainage. Quantification of heavy metal toxicity to mixed cultures of SRB is complicated by the confounding effects of metal hydroxide and sulfide precipitation, biosorption, and complexation with the constituents of the reaction matrix. The objective of this paper was to demonstrate that measurements of dissolved metal concentrations could be used to determine the toxicity parameters for mixed cultures of sulfate-reducing bacteria. The effective concentration, 100% (EC100), the lowest initial dissolved metal concentrations at which no sulfate reduction is observed, and the effective concentration, 50% (EC50), the initial dissolved metal concentrations resulting in a 50% decrease in sulfate reduction, for copper and zinc were determined in the present study by means of nondestructive, rapid physical and chemical analytical techniques. The reaction medium used in the experiments was designed specifically (in terms of pH and chemical composition) to provide the nutrients necessary for the sulfidogenic activity of the SRB and to preclude chemical precipitation of the metals under investigation. The toxicity-mitigating effects of biosorption of dissolved metals were also quantified. Anaerobic Hungate tubes were set up (at least in triplicate) and monitored for sulfate-reduction activity. The onset of SRB activity was detected by the blackening of the reaction mixture because of formation of insoluble ferrous sulfide. The EC100 values were found to be 12 mg/L for copper and 20 mg/L for zinc. The dissolved metal concentration measurements were effective as the indicators of the effect of the

  5. Assessment of Attentional Workload while Driving by Eye-fixation-related Potentials

    Science.gov (United States)

    Takeda, Yuji; Yoshitsugu, Noritoshi; Itoh, Kazuya; Kanamori, Nobuhiro

    How do drivers cope with the attentional workload of in-vehicle information technology? In the present study, we propose a new psychophysiological measure for assessing drivers' attention: eye-fixation-related potential (EFRP). EFRP is a kind of event-related brain potential measurable at the eye-movement situation that reflects how closely observers examine visual information at the eye-fixated position. In the experiment, the effects of verbal working memory load and spatial working memory load during simulated driving were examined by measuring the number of saccadic eye-movements and EFRP as the indices of drivers' attention. The results showed that the spatial working memory load affected both the number of saccadic eye-movements and the amplitude of the P100 component of EFRP, whereas the verbal working memory load affected only the number of saccadic eye-movements. This implies that drivers can perform time-sharing processing between driving and the verbal working memory task, but the decline of accuracy of visual processing during driving is inescapable when the spatial working memory load is given. The present study suggests that EFRP can provide a new index of drivers' attention, other than saccadic eye-movements.

  6. EC environmental legislation and the European oil industry

    International Nuclear Information System (INIS)

    Luding, W.G.

    1993-01-01

    EUROPIA has 32 ordinary member companies which own and operate more than 95% of EC refining capacity, plus three associate member companies from EFTA countries. A large part of EUROPIA's efforts is devoted to environmental issues. Among its initial actions, EUROPIA developed Guiding Principles for environmental management which have been adopted by all member companies. This article can only highlight some of the key areas of EC environmental policy of interest to the oil industry. Most of the comments will refer to air pollution issues but, of course, water and ground pollution and waste are equally important subjects. (orig./HS)

  7. VRPI Temporal Progression of Closed Globe Injury from Blast Exposure

    Science.gov (United States)

    2015-09-01

    significant increases in VEGF have been reported in many ocular disorders including diabetic retinopathy , diffuse macular edema, retinal vein...Open globe injury is often readily identifiable and typically undergoes urgent surgical repair. However, closed globe injury may not be detected ...including shrapnel or debris to the eye, is easily identified and rapidly treated. Closed globe trauma may not be detected right away, and little is

  8. Kinetic study on ligand exchange reaction between EC and 99mTc-GH

    International Nuclear Information System (INIS)

    Wu Chunying; Luo Shineng; Fang Ping; Huang Heyun; Xie Minhao; Meng Hong

    1995-01-01

    The ligand exchange reaction between EC and 99m Tc-GH and its influence factors such as concentrations of EC and pH were described. The concentration of EC has no influence on the exchange reaction rate constant, while pH is the most important influence factor. The rate constants of ligand exchange reaction at different pH values were determined. The results showed that in order to make the labelling yield of 99m Tc-EC higher than 90%, pH of the reaction must be higher than 8

  9. Deposition of HgTe by electrochemical atomic layer epitaxy (EC-ALE)

    CSIR Research Space (South Africa)

    Venkatasamy, V

    2006-04-01

    Full Text Available This paper describes the first instance of HgTe growth by electrochemical atomic layer epitaxy (EC-ALE). EC-ALE is the electrochemical analog of atomic layer epitaxy (ALE) and atomic layer deposition (ALD), all of which are based on the growth...

  10. Analysis of ATLAS FLB-EC6 Experiment using SPACE Code

    International Nuclear Information System (INIS)

    Lee, Donghyuk; Kim, Yohan; Kim, Seyun

    2013-01-01

    The new code is named SPACE(Safety and Performance Analysis Code for Nuclear Power Plant). As a part of code validation effort, simulation of ATLAS FLB(Feedwater Line Break) experiment using SPACE code has been performed. The FLB-EC6 experiment is economizer break of a main feedwater line. The calculated results using the SPACE code are compared with those from the experiment. The ATLAS FLB-EC6 experiment, which is economizer feedwater line break, was simulated using the SPACE code. The calculated results were compared with those from the experiment. The comparisons of break flow rate and steam generator water level show good agreement with the experiment. The SPACE code is capable of predicting physical phenomena occurring during ATLAS FLB-EC6 experiment

  11. DOD Electronic Commerce (EC)/Electronic Data Interchange (EDI) in contracting report

    Science.gov (United States)

    1993-12-01

    Use of Electronic Commerce (EC)/Electronic Data Interchange (EDI) to support Department of Defense (DoD) procurement processes has been under consideration for some time. A 1988 Deputy Secretary of Defense memo calls for maximum use of EDI, based on 10 years of DoD EDI investigation and experiments. In 1990, Defense Management Review Decision 941 stated, 'The strategic goal of DoD's current efforts is to provide the department with the capability to initiate, conduct, and maintain its external business related transactions and internal logistics, contracting, and financial activities without requiring the use of hard copy media.' The EC in Contracting PAT membership reflected a broad cross section of Military Services and Defense Agencies working on a full-time basis for 60 days. The diversity of the EC in Contracting PAT ensured that the needs and concerns of all DoD components were addressed during the creation of the report. The resultant plan, therefore, represents a comprehensive approach for implementing EC throughout the DoD.

  12. ECS: Efficient Communication Scheduling for Underwater Sensor Networks

    Directory of Open Access Journals (Sweden)

    Lu Hong

    2011-03-01

    Full Text Available TDMA protocols have attracted a lot of attention for underwater acoustic sensor networks (UWSNs, because of the unique characteristics of acoustic signal propagation such as great energy consumption in transmission, long propagation delay and long communication range. Previous TDMA protocols all allocated transmission time to nodes based on discrete time slots. This paper proposes an efficient continuous time scheduling TDMA protocol (ECS for UWSNs, including the continuous time based and sender oriented conflict analysis model, the transmission moment allocation algorithm and the distributed topology maintenance algorithm. Simulation results confirm that ECS improves network throughput by 20% on average, compared to existing MAC protocols.

  13. Six-year clinical study of firework-related eye injuries in North China.

    Science.gov (United States)

    Kong, Yichun; Tang, Xin; Kong, Baohuan; Jiang, Hao; Chen, Ying

    2015-01-01

    To analyse the demographic data, clinical characteristics, management and prognosis of patients with firework-related eye injuries. A retrospective review was performed of patients with eye injuries related to fireworks referred to TianJin Eye Hospital in North China from 2008 to 2013. Demographic information, clinical features, management and visual outcome were analysed and prognosis factors were evaluated. Ninety-nine patients (86 men) with 118 eye injuries were enrolled in the study. The average age of the patients was 32.0±20.5 years; 70/99 (70.7%) were aged >20 years. Eighty-one of the patients had been lighting the fireworks while the rest were bystanders. The main ophthalmic manifestations were hyphaema, vitreous haemorrhage, corneal/sclera/corneoscleral open globe injury, eyelid laceration, traumatic cataract, retinal/choroid detachment, endophthalmitis and intraocular foreign body (IOFB). Ninety patients required surgical intervention including repair of open globe injury, vitrectomy, cataract extraction and enucleation. 56/118 eyes (47.5%) received multiple operations. After treatment, final best-corrected visual acuity (BCVA) significantly improved (p=0.015). Some factors were significantly correlated with better final BCVA, including initial BCVA (p=0.036), closed globe injury (p=0.031), absence of endophthalmitis (p=0.014), absence of IOFB (p=0.024) and absence of retinal detachment (p=0.046). Firework-related eye injuries mainly occur in adult men and result in severe visual damage. The most common clinical manifestations are hyphaema and vitreous haemorrhage. Better initial BCVA and closed globe injury have a better visual result while endophthalmitis, IOFB and retinal detachment have a negative visual outcome. Improved eye protection, along with enhanced public education and legal ban on fireworks, could reduce the incidence of eye injuries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  14. The Impact of a Submaximal Level of Exercise on Balance Performance in Older Persons

    Directory of Open Access Journals (Sweden)

    Hani Asilah Alias

    2014-01-01

    Full Text Available Objective. The purpose of this study was to determine the impact of a submaximal level of exercise on balance performance under a variety of conditions. Material and Method. Thirteen community-dwelling older persons with intact foot sensation (age = 66.69 ± 8.17 years, BMI = 24.65 ± 4.08 kg/m2, female, n=6 volunteered to participate. Subjects’ balance performances were measured using the Modified Clinical Test of Sensory Integration of Balance (mCTSIB at baseline and after test, under four conditions of stance: (1 eyes-opened firm-surface (EOF, (2 eyes-closed firm-surface (ECF, (3 eyes-opened soft-surface (EOS, and (4 eyes-closed soft-surface (ECS. The 6-minute walk test (6MWT protocol was used to induce the submaximal level of exercise. Data was analyzed using the Wilcoxon Signed-Rank Test. Results. Balance changes during EOF (z=0.00, P=1.00 and ECF (z=-1.342, P=0.180 were not significant. However, balance changes during EOS (z=-2.314, P=0.021 and ECS (z=-3.089, P=0.02 were significantly dropped after the 6MWT. Conclusion. A submaximal level of exercise may influence sensory integration that in turn affects balance performance, particularly on an unstable surface. Rehabilitation should focus on designing intervention that may improve sensory integration among older individuals with balance deterioration in order to encourage functional activities.

  15. A global inventory of aircraft NO{sub x} emissions (ANCAT/EC 2). A revised inventory (1996) by the ECAC/ANCAT and EC working group

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, R M [Great Minister House, London (United Kingdom). Dept. of Transfert London

    1998-12-31

    Results of the ANCAT/EC 2 inventory produced by the European ANCAT/EC emissions inventory group is reported. The base year inventory has been completed and is currently being written up for report publication. The ANCAT/EC 2 inventory in the base year, 1991/92, has accounted for a total fuel burn of 132.5 Tg/yr and a NO{sub x} mass of 1.82 Tg/yr. The civil subsonic fleet average emissions index is EI NO{sub x} 13.9. The inventory has accounted for 80% of the IEA refined jet fuel total for 1992. The forecast 2015 inventory accounts for 289.4 Tg/yr fuel and 3.48 Tg/yr NO{sub x}, increases of 118% and 91% respectively. Both datasets will be reported fully in the next few months. (author) 5 refs.

  16. A global inventory of aircraft NO{sub x} emissions (ANCAT/EC 2). A revised inventory (1996) by the ECAC/ANCAT and EC working group

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, R.M. [Great Minister House, London (United Kingdom). Dept. of Transfert London

    1997-12-31

    Results of the ANCAT/EC 2 inventory produced by the European ANCAT/EC emissions inventory group is reported. The base year inventory has been completed and is currently being written up for report publication. The ANCAT/EC 2 inventory in the base year, 1991/92, has accounted for a total fuel burn of 132.5 Tg/yr and a NO{sub x} mass of 1.82 Tg/yr. The civil subsonic fleet average emissions index is EI NO{sub x} 13.9. The inventory has accounted for 80% of the IEA refined jet fuel total for 1992. The forecast 2015 inventory accounts for 289.4 Tg/yr fuel and 3.48 Tg/yr NO{sub x}, increases of 118% and 91% respectively. Both datasets will be reported fully in the next few months. (author) 5 refs.

  17. EC6 for Darlington - a managed-enhancements replication project

    International Nuclear Information System (INIS)

    Soulard, M.R.

    2011-01-01

    CANDU 6 design has a well-deserved reputation for lifetime performance and on-time, on-schedule construction. Candu Energy is finalizing development of an upgraded reactor product, the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and adds enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Some of the key features incorporated into the EC6 include increasing the plant's power output, shortening the overall project schedule, addressing obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the operating plants. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. An array of health monitoring equipment are also installed to foretell impending equipment problems, which can be acted upon, avoiding complications that could result in forced shutdowns. Improvements to the fire protection system and enhanced security features will further protect the assets. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; other markets are also being pursued. The EC6 reactor is designed for a target lifetime capacity factor of 92% including 94% year-to-year and a 1% Forced Loss Rate. Since the number and duration of maintenance outages impact plant capacity factors, periodic short duration maintenance outages of less than a month once every 36 months is a key target of the EC6 reactor. This objective is achieved by automating a number of tasks such as shutdown systems testing. The majority

  18. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    Science.gov (United States)

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  19. Translation and validation of the Dutch version of the Effective Consumer Scale (EC-17)

    NARCIS (Netherlands)

    ten Klooster, Peter M.; Taal, Erik; Tjin-Kam-Jet-Siemons, Liseth; Oostveen, J.C.M.; Oostveen, Johanna C.M.; Harmsen, Etelka J.; Tugwell, Peter S.; Rader, Tamara; Lyddiatt, Anne; van de Laar, Mart A F J

    2013-01-01

    PURPOSE: The Effective Consumer Scale (EC-17) measures the skills of musculoskeletal patients in managing their own healthcare. The objectives of this study were to translate the EC-17 into Dutch and to further evaluate its psychometric properties. METHODS: The EC-17 was translated and cognitively

  20. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  1. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  2. Effect of Viscous Agents on Corneal Density in Dry Eye Disease.

    Science.gov (United States)

    Wegener, Alfred R; Meyer, Linda M; Schönfeld, Carl-Ludwig

    2015-10-01

    To investigate the effect of the viscous agents, hydroxypropyl methylcellulose (HPMC), carbomer, povidone, and a combination of HPMC and povidone on corneal density in patients with dry eye disease. In total, 98 eyes of 49 patients suffering from dry eye and 65 eyes of 33 healthy age-matched individuals were included in this prospective, randomized study. Corneal morphology was documented with Scheimpflug photography and corneal density was analyzed in 5 anatomical layers (epithelium, bowman membrane, stroma, descemet's membrane, and endothelium). Corneal density was evaluated for the active ingredients HPMC, carbomer, povidone, and a combination of HPMC and povidone as the viscous agents contained in the artificial tear formulations used by the dry eye patients. Data were compared to the age-matched healthy control group without medication. Corneal density in dry eye patients was reduced in all 5 anatomical layers compared to controls. Corneal density was highest and very close to control in patients treated with HPMC containing ocular lubricants. Patients treated with lubricants, including carbomer as the viscous agent displayed a significant reduction of corneal density in layers 1 and 2 compared to control. HPMC containing ocular lubricants can help to maintain physiological corneal density and may be beneficial in the treatment of dry eye disease.

  3. Ankylosing Spondylitis and Posture Control: The Role of Visual Input

    OpenAIRE

    De Nunzio, Alessandro Marco; Iervolino, Salvatore; Zincarelli, Carmela; Di Gioia, Luisa; Rengo, Giuseppe; Multari, Vincenzo; Peluso, Rosario; Di Minno, Matteo Nicola Dario; Pappone, Nicola

    2015-01-01

    Objectives. To assess the motor control during quiet stance in patients with established ankylosing spondylitis (AS) and to evaluate the effect of visual input on the maintenance of a quiet posture. Methods. 12 male AS patients (mean age 50.1 ± 13.2 years) and 12 matched healthy subjects performed 2 sessions of 3 trials in quiet stance, with eyes open (EO) and with eyes closed (EC) on a baropodometric platform. The oscillation of the centre of feet pressure (CoP) was acquired. Indices of stab...

  4. The Correlation between Daily Lens Wear Duration and Dry Eye Syndrome.

    Science.gov (United States)

    Lubis, Rodiah Rahmawaty; Gultom, Monica Tumiar Hanna

    2018-05-20

    To analyze the correlation between the daily lens wear duration and dry eye syndrome. This study was an analytic cross sectional study using consecutive sampling conducted among the students in Economy and Bussiness Faculty and Faculty of Humanities in University of Sumatera Utara aged between 17 to 23 that wore contact lens continously for at least a year and 5 days a week. The symptoms were assessed using Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and interview about their contact lens comfort; eye drops usage, contact lens washing habit, daily circumstances, places to buy contact lens and personal experince in wearing contact lens. The questionnaire was completed by 53 students. All of them were female and wore softlens wearers. The mean duration of daily wear was 8.19 ± 2.20 hours. The most common symptom experienced was dry eye and the least symptom experienced was removing lens. The most frequent symptom experienced was closing eyes and the least frequent symptom experienced was removing lenses. This study used Exact Test as analysis statistic method. The result was p > 0.05 which means there is no correlation between daily lens wear duration and dry eye syndrome. This study showed that dry eye syndrome was not correlated with daily lens wear duration, but affected by many factors such as contact lens, lens care solution, eye drops usage and environment.

  5. The representation of tropical upper tropospheric water in EC Earth V2

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M.S. [Chalmers University of Technology, Department of Earth and Space Sciences, Goeteburg (Sweden); Swedish Meteorological and Hydrological Institute (SMHI), Norrkoeping (Sweden); Eriksson, P.; Murtagh, D.P. [Chalmers University of Technology, Department of Earth and Space Sciences, Goeteburg (Sweden); Eliasson, S. [Luleaa University of Technology, Department of Computer Science, Electrical and Space Engineering, Kiruna (Sweden); Jones, C.G. [Swedish Meteorological and Hydrological Institute (SMHI), Norrkoeping (Sweden); Forbes, R.M. [ECMWF, Reading, Berkshire (United Kingdom)

    2012-12-15

    Tropical upper tropospheric humidity, clouds, and ice water content, as well as outgoing longwave radiation (OLR), are evaluated in the climate model EC Earth with the aid of satellite retrievals. The Atmospheric Infrared Sounder and Microwave Limb Sounder together provide good coverage of relative humidity. EC Earth's relative humidity is in fair agreement with these observations. CloudSat and CALIPSO data are combined to provide cloud fractions estimates throughout the altitude region considered (500-100 hPa). EC Earth is found to overestimate the degree of cloud cover above 200 hPa and underestimate it below. Precipitating and non-precipitating EC Earth ice definitions are combined to form a complete ice water content. EC Earth's ice water content is below the uncertainty range of CloudSat above 250 hPa, but can be twice as high as CloudSat's estimate in the melting layer. CERES data show that the model underestimates the impact of clouds on OLR, on average with about 9 W m{sup -2}. Regionally, EC Earth's outgoing longwave radiation can be {proportional_to}20 W m{sup -2} higher than the observation. A comparison to ERA-Interim provides further perspectives on the model's performance. Limitations of the satellite observations are emphasised and their uncertainties are, throughout, considered in the analysis. Evaluating multiple model variables in parallel is a more ambitious approach than is customary. (orig.)

  6. Egg cell-secreted EC1 triggers sperm cell activation during double fertilization.

    Science.gov (United States)

    Sprunck, Stefanie; Rademacher, Svenja; Vogler, Frank; Gheyselinck, Jacqueline; Grossniklaus, Ueli; Dresselhaus, Thomas

    2012-11-23

    Double fertilization is the defining characteristic of flowering plants. However, the molecular mechanisms regulating the fusion of one sperm with the egg and the second sperm with the central cell are largely unknown. We show that gamete interactions in Arabidopsis depend on small cysteine-rich EC1 (EGG CELL 1) proteins accumulating in storage vesicles of the egg cell. Upon sperm arrival, EC1-containing vesicles are exocytosed. The sperm endomembrane system responds to exogenously applied EC1 peptides by redistributing the potential gamete fusogen HAP2/GCS1 (HAPLESS 2/GENERATIVE CELL SPECIFIC 1) to the cell surface. Furthermore, fertilization studies with ec1 quintuple mutants show that successful male-female gamete interactions are necessary to prevent multiple-sperm cell delivery. Our findings provide evidence that mutual gamete activation, regulated exocytosis, and sperm plasma membrane modifications govern flowering plant gamete interactions.

  7. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    Science.gov (United States)

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. EC4IT - A Guide to European Commission Projects for CERN/IT department

    CERN Document Server

    Jones, R

    2012-01-01

    European Commission (EC) projects represent an important source of external funding for a number of activities in which IT department is involved. The EC has a set of procedures and formalities for the preparation, negotiation, execution and completion of projects that are different to those normally used at CERN. This document gives an overview of the administrative, financial, reporting and managerial steps involved in participating in an EC project.

  9. Study of wavefront aberration in DR patients with different degree of dry eye

    Directory of Open Access Journals (Sweden)

    Jin-Ran Fang

    2018-05-01

    Full Text Available AIM: To compare the changes of wavefront aberrations in patients with diabetic retinopathy(DRand with different degrees of dry eye and to explore the reasons of visual quality decline in them. METHODS: We randomly selected 40 eyes in our hospital for treatment with DR and varying degrees of dry eye, and 40 eyes of normal control group. Topcon KR-1W visual quality analyzer was used to record the mean square the total high order corneal aberration, spherical aberration, comatic aberration and trefoil aberration of cornea with pupil diameters of 4mm and 6mm. Analysis of variance were used to compare the wavefront aberrations and the aberration values in the control group and in patients with diabetic retinopathy and with different degrees of dry eye. RESULTS: For 4mm and 6mm pupil diameters, nondiabetic retinopathy(NDRwith dry eye group, the nonproliferative diabetic retinopathy(NPDRwith dry eye group and proliferative diabetic retinopathy(PDRdry eye group had significantly increased tHOA, coma and trefoil compared with the contrast group(PPCONCLUSION: Dry eye of diabetic retinopathy with different degrees is closely related to the increase of wavefront aberration. Increased wavefront aberration may be one of the reasons to reduced visual quality in patients with diabetic retinopathy and with dry eye, and provide the basis for the decline of visual function of diabetic patients with dry eye.

  10. The Effects of Eye-Closure and “Ear-Closure” on Recall of Visual and Auditory Aspects of a Criminal Event

    Directory of Open Access Journals (Sweden)

    Annelies Vredeveldt

    2012-05-01

    Full Text Available Previous research has shown that closing the eyes can facilitate recall of semantic and episodic information. Here, two experiments are presented which investigate the theoretical underpinnings of the eye-closure effect and its auditory equivalent, the “ear-closure” effect. In Experiment 1, participants viewed a violent videotaped event and were subsequently interviewed about the event with eyes open or eyes closed. Eye-closure was found to have modality-general benefits on coarse-grain correct responses, but modality-specific effects on fine-grain correct recall and incorrect recall (increasing the former and decreasing the latter. In Experiment 2, participants viewed the same event and were subsequently interviewed about it, either in quiet conditions or while hearing irrelevant speech. Contrary to expectations, irrelevant speech did not significantly impair recall performance. This null finding might be explained by the absence of social interaction during the interview in Experiment 2. In conclusion, eye-closure seems to involve both general and modality-specific processes. The practical implications of the findings are discussed.

  11. Perceptual Aspects of Postural Control: Does Pure Proprioceptive Training Exist?

    Science.gov (United States)

    Nagy, Edit; Posa, Gabriella; Finta, Regina; Szilagyi, Levente; Sziver, Edit

    2018-06-01

    As proprioceptive training is popular for injury prevention and rehabilitation, we evaluated its effect on balance parameters and assessed the frequency spectra of postural sway linked with the various sensory channels. We recorded the Center of Mass displacement of 30 healthy student research participants (mean age = 21.63; SD = 1.29 years) with a single force plate under eyes open (EO) and eyes closed (EC) positions while standing on either a firm or foam surface, both before and after an 8-week balance training intervention on a foam surface with EC. We subjected the data to frequency power spectral analysis to find any differences between the frequency bands, linked with various sensory data. On the foam surface in the EC condition, the sway path decreased significantly after proprioceptive training, but, on the firm surface in the EC condition, there was no change. On the foam surface in the EC condition, there was also a significant decrease in frequency power postproprioceptive training in the medium-to-low frequency band. While our data indicate better posttraining balance skills, improvements were task specific to the trained condition, with no transfer of the acquired skill, even to a similar, easier condition. As training improved the middle-low frequency band, linked with vestibular signals, this intervention is better described as balance than "proprioceptive" training.

  12. Eye movements of patients with tunnel vision while walking.

    Science.gov (United States)

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  13. Delayed Anticipatory Spoken Language Processing in Adults with Dyslexia—Evidence from Eye-tracking.

    Science.gov (United States)

    Huettig, Falk; Brouwer, Susanne

    2015-05-01

    It is now well established that anticipation of upcoming input is a key characteristic of spoken language comprehension. It has also frequently been observed that literacy influences spoken language processing. Here, we investigated whether anticipatory spoken language processing is related to individuals' word reading abilities. Dutch adults with dyslexia and a control group participated in two eye-tracking experiments. Experiment 1 was conducted to assess whether adults with dyslexia show the typical language-mediated eye gaze patterns. Eye movements of both adults with and without dyslexia closely replicated earlier research: spoken language is used to direct attention to relevant objects in the environment in a closely time-locked manner. In Experiment 2, participants received instructions (e.g., 'Kijk naar de(COM) afgebeelde piano(COM)', look at the displayed piano) while viewing four objects. Articles (Dutch 'het' or 'de') were gender marked such that the article agreed in gender only with the target, and thus, participants could use gender information from the article to predict the target object. The adults with dyslexia anticipated the target objects but much later than the controls. Moreover, participants' word reading scores correlated positively with their anticipatory eye movements. We conclude by discussing the mechanisms by which reading abilities may influence predictive language processing. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Effects of Watching Eyes and Norm Cues on Charitable Giving in a Surreptitious Behavioral Experiment

    Directory of Open Access Journals (Sweden)

    Moe Fathi

    2014-04-01

    Full Text Available A series of experimental studies by multiple groups of researchers have found that displaying images of watching eyes causes people to behave more prosocially. It is not yet clear whether watching eyes increase prosocial motivation per se, or whether they simply make people's behavior more normative. Here, we report results from a surreptitious behavioral experiment examining the impacts of watching eye images and cues to local norms on charitable donations in a controlled setting. Eye images significantly increased average donations. Eye images did not make people conform more closely to the apparent norm overall. Instead, there were different patterns according to the apparent norm. For an apparent norm of small donations, eye images made many participants more generous than the norm. For an apparent norm of large donations, there was an excess of participants giving zero in the no-eyes treatment, which was abolished in the eyes treatment. Our results can be explained by a combination of watching eyes increasing prosocial motivation and reluctance to leave a donation visibly less generous than the norm.

  15. Present status of developing petroleum-substituting energy (EC)

    Science.gov (United States)

    1993-03-01

    The EC has had approximately 50% of its total energy demand supplied by imports from the exterior of the Community. Hence, it is getting important to develop oil-substituting renewable energy as well as to curtail the emission of carbon dioxide. In consideration of these situations, the results of investigation on the energy policy of the European Community are described. The policy comprises three courses: European Energy Charter, formation of an open European Community energy market, and environmental conservation. Particularly, concerning the reduction of carbon dioxide emission, the EC Council has decided to introduce carbon dioxide taxation so as to suppress the carbon dioxide emission in the year 2000 to the 1990 level. The arrangement for its introduction, however, encountered with difficulties because of the opposition of various countries other than the European Community and the industrial world of the European Community. Legislation of the investment promotion law for energy saving and the construction of infrastructure footing and an information network are ineffective due to the sluggish fuel price and economic recession. A plurality of EC member countries are advancing a comprehensive activity within the framework of the joint programs of research, development, and demonstration set for the renewable energy policy ensuring energy supply and environmental harmonization.

  16. Eye movement training is most effective when it involves a task-relevant sensorimotor decision.

    Science.gov (United States)

    Fooken, Jolande; Lalonde, Kathryn M; Mann, Gurkiran K; Spering, Miriam

    2018-04-01

    Eye and hand movements are closely linked when performing everyday actions. We conducted a perceptual-motor training study to investigate mutually beneficial effects of eye and hand movements, asking whether training in one modality benefits performance in the other. Observers had to predict the future trajectory of a briefly presented moving object, and intercept it at its assumed location as accurately as possible with their finger. Eye and hand movements were recorded simultaneously. Different training protocols either included eye movements or a combination of eye and hand movements with or without external performance feedback. Eye movement training did not transfer across modalities: Irrespective of feedback, finger interception accuracy and precision improved after training that involved the hand, but not after isolated eye movement training. Conversely, eye movements benefited from hand movement training or when external performance feedback was given, thus improving only when an active interceptive task component was involved. These findings indicate only limited transfer across modalities. However, they reveal the importance of creating a training task with an active sensorimotor decision to improve the accuracy and precision of eye and hand movements.

  17. Reshaping Text Data for Efficient Processing on Amazon EC2

    Directory of Open Access Journals (Sweden)

    Gabriela Turcu

    2011-01-01

    Full Text Available Text analysis tools are nowadays required to process increasingly large corpora which are often organized as small files (abstracts, news articles, etc.. Cloud computing offers a convenient, on-demand, pay-as-you-go computing environment for solving such problems. We investigate provisioning on the Amazon EC2 cloud from the user perspective, attempting to provide a scheduling strategy that is both timely and cost effective. We derive an execution plan using an empirically determined application performance model. A first goal of our performance measurements is to determine an optimal file size for our application to consume. Using the subset-sum first fit heuristic we reshape the input data by merging files in order to match as closely as possible the desired file size. This also speeds up the task of retrieving the results of our application, by having the output be less segmented. Using predictions of the performance of our application based on measurements on small data sets, we devise an execution plan that meets a user specified deadline while minimizing cost.

  18. Cooperative Fuzzy Games Approach to Setting Target Levels of ECs in Quality Function Deployment

    Directory of Open Access Journals (Sweden)

    Zhihui Yang

    2014-01-01

    Full Text Available Quality function deployment (QFD can provide a means of translating customer requirements (CRs into engineering characteristics (ECs for each stage of product development and production. The main objective of QFD-based product planning is to determine the target levels of ECs for a new product or service. QFD is a breakthrough tool which can effectively reduce the gap between CRs and a new product/service. Even though there are conflicts among some ECs, the objective of developing new product is to maximize the overall customer satisfaction. Therefore, there may be room for cooperation among ECs. A cooperative game framework combined with fuzzy set theory is developed to determine the target levels of the ECs in QFD. The key to develop the model is the formulation of the bargaining function. In the proposed methodology, the players are viewed as the membership functions of ECs to formulate the bargaining function. The solution for the proposed model is Pareto-optimal. An illustrated example is cited to demonstrate the application and performance of the proposed approach.

  19. Cooperative fuzzy games approach to setting target levels of ECs in quality function deployment.

    Science.gov (United States)

    Yang, Zhihui; Chen, Yizeng; Yin, Yunqiang

    2014-01-01

    Quality function deployment (QFD) can provide a means of translating customer requirements (CRs) into engineering characteristics (ECs) for each stage of product development and production. The main objective of QFD-based product planning is to determine the target levels of ECs for a new product or service. QFD is a breakthrough tool which can effectively reduce the gap between CRs and a new product/service. Even though there are conflicts among some ECs, the objective of developing new product is to maximize the overall customer satisfaction. Therefore, there may be room for cooperation among ECs. A cooperative game framework combined with fuzzy set theory is developed to determine the target levels of the ECs in QFD. The key to develop the model is the formulation of the bargaining function. In the proposed methodology, the players are viewed as the membership functions of ECs to formulate the bargaining function. The solution for the proposed model is Pareto-optimal. An illustrated example is cited to demonstrate the application and performance of the proposed approach.

  20. Influence of spontaneous nystagmus with eyes closed on computerized vestibular exam of patients with chronic peripheral

    Directory of Open Access Journals (Sweden)

    Shin, Elizabeth

    2010-06-01

    Full Text Available Introduction: The spontaneous nystagmus with eyes closed (NEOF can modify the results obtained during some evidence of vestibular, leading to erroneous conclusions. Objective: To characterize the patients and the type of influence on the evidence of NEOF vectonystagmography digital. Method: Retrospective study based on survey charts of patients with the presence of NEOF vectonystagmography digital, in the Outpatient Equilibriometria UNIFESP-EPM, in the years 2000 to 2007. Comparisons were made between genders, ages, direction, angular velocity of NEOF, completion of entrance examination and its influence on the results of caloric testing. Results: We found 73.7% of the population was female, mean age of 55.08 years; NEOF prevalence of horizontal and angular velocity smaller than 7o/s in 86.7%. 59% had some kind of influence caused by the caloric test NEOF as inversion, hyporeflexia, hyperreflexia, nystagmus directional preponderance (NDP and labyrinthine preponderance (LP changed. The most prevalent findings were normal vestibular tests (EVN and bilateral irritative peripheral vestibular syndrome (BIPVS. 38.7% caloric ice and realized these cases it was possible to reach a conclusion in 79%. Conclusion: The NEOF most common was the horizontal type, with VACL less than 7o/s, influencing the majority of examinations and only the results of caloric testing the air, with reversal of post-caloric nystagmus, hyperreflexia and hyporeflexia, NDP and PL altered; the findings were more prevalent and BIPVS EVN, and the caloric test the influence of ice withdrew NEOF in most individuals, enabling to reach a final conclusion.

  1. Quantitative Measurement of Eyestrain on 3D Stereoscopic Display Considering the Eye Foveation Model and Edge Information

    Directory of Open Access Journals (Sweden)

    Hwan Heo

    2014-05-01

    Full Text Available We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user’s gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD, stereoscopic disparity (SD, frame cancellation effect (FCE, and edge component (EC of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors.

  2. EC-LEDS Mexico: Advancing Clean Energy Goals

    Energy Technology Data Exchange (ETDEWEB)

    2016-07-01

    EC-LEDS works with the government of Mexico to help meet its goals of reducing greenhouse gas emissions from the energy sector. The program targets specific, highly technical areas where Mexico has indicated the program can add value and make an impact.

  3. EC-LEDS Supports the Low-Carbon Transition

    Energy Technology Data Exchange (ETDEWEB)

    2016-09-01

    EC-LEDS is a flagship U.S. government-led effort that assists countries to create and implement low emission development strategies, or LEDS -- development frameworks that promote sustainable social and economic development while reducing greenhouse gas emissions over the medium to long term.

  4. Overview of the ITER EC H and CD system and its capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Omori, T., E-mail: toshimichi.omori@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Henderson, M.A. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Albajar, F. [Fusion for Energy, C/Josep Pla 2, Torres Diagonal Litoral-B3, E-08019 Barcelona (Spain); Alberti, S. [CRPP-Association EURATOM-Confederation Suisse, EPFL Ecublens, CH-1015 Lausanne (Switzerland); Baruah, U. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India); Bigelow, T.S. [US ITER Project Office, ORNL, 055 Commerce Park, PO Box 2008, Oak Ridge, TN 37831 (United States); Beckett, B. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Bertizzolo, R. [CRPP-Association EURATOM-Confederation Suisse, EPFL Ecublens, CH-1015 Lausanne (Switzerland); Bonicelli, T. [Fusion for Energy, C/Josep Pla 2, Torres Diagonal Litoral-B3, E-08019 Barcelona (Spain); Bruschi, A. [Istituto di Fisica del Plasma, Association EURATOM-ENEA-CNR, Milano (Italy); Caughman, J.B. [US ITER Project Office, ORNL, 055 Commerce Park, PO Box 2008, Oak Ridge, TN 37831 (United States); Chavan, R. [CRPP-Association EURATOM-Confederation Suisse, EPFL Ecublens, CH-1015 Lausanne (Switzerland); Cirant, S. [Istituto di Fisica del Plasma, Association EURATOM-ENEA-CNR, Milano (Italy); Collazos, A. [CRPP-Association EURATOM-Confederation Suisse, EPFL Ecublens, CH-1015 Lausanne (Switzerland); Cox, D.; Darbos, C. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Baar, M.R. de [Association EURATOM-FOM, 3430 BE Nieuwegein (Netherlands); Denisov, G. [Institute of Applied Physics, 46 Ulyanov Street, Nizhny Novgorod 603950 (Russian Federation); Farina, D. [Istituto di Fisica del Plasma, Association EURATOM-ENEA-CNR, Milano (Italy); Gandini, F. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    The Electron Cyclotron (EC) system for the ITER tokamak is designed to inject {>=}20 MW RF power into the plasma for Heating and Current Drive (H and CD) applications. The EC system consists of up to 26 gyrotrons (between 1 and 2 MW each), the associated power supplies, 24 transmission lines and 5 launchers. The EC system has a diverse range of applications including central heating and current drive, current profile tailoring and control of plasma magneto-hydrodynamic (MHD) instabilities such as the sawtooth and neoclassical tearing modes (NTMs). This diverse range of applications requires the launchers to be capable of depositing the EC power across nearly the entire plasma cross section. This is achieved by two types of antennas: an equatorial port launcher (capable of injecting up to 20 MW from the plasma axis to mid-radius) and four upper port launchers providing access from inside of mid radius to near the plasma edge. The equatorial launcher design is optimized for central heating, current drive and profile tailoring, while the upper launcher should provide a very focused and peaked current density profile to control the plasma instabilities. The overall EC system has been modified during the past 3 years taking into account the issues identified in the ITER design review from 2007 and 2008 as well as integrating new technologies. This paper will review the principal objectives of the EC system, modifications made during the past 2 years and how the design is compliant with the principal objectives.

  5. Overview of the ITER EC H and CD system and its capabilities

    International Nuclear Information System (INIS)

    Omori, T.; Henderson, M.A.; Albajar, F.; Alberti, S.; Baruah, U.; Bigelow, T.S.; Beckett, B.; Bertizzolo, R.; Bonicelli, T.; Bruschi, A.; Caughman, J.B.; Chavan, R.; Cirant, S.; Collazos, A.; Cox, D.; Darbos, C.; Baar, M.R. de; Denisov, G.; Farina, D.; Gandini, F.

    2011-01-01

    The Electron Cyclotron (EC) system for the ITER tokamak is designed to inject ≥20 MW RF power into the plasma for Heating and Current Drive (H and CD) applications. The EC system consists of up to 26 gyrotrons (between 1 and 2 MW each), the associated power supplies, 24 transmission lines and 5 launchers. The EC system has a diverse range of applications including central heating and current drive, current profile tailoring and control of plasma magneto-hydrodynamic (MHD) instabilities such as the sawtooth and neoclassical tearing modes (NTMs). This diverse range of applications requires the launchers to be capable of depositing the EC power across nearly the entire plasma cross section. This is achieved by two types of antennas: an equatorial port launcher (capable of injecting up to 20 MW from the plasma axis to mid-radius) and four upper port launchers providing access from inside of mid radius to near the plasma edge. The equatorial launcher design is optimized for central heating, current drive and profile tailoring, while the upper launcher should provide a very focused and peaked current density profile to control the plasma instabilities. The overall EC system has been modified during the past 3 years taking into account the issues identified in the ITER design review from 2007 and 2008 as well as integrating new technologies. This paper will review the principal objectives of the EC system, modifications made during the past 2 years and how the design is compliant with the principal objectives.

  6. Belle monte-carlo production on the Amazon EC2 cloud

    International Nuclear Information System (INIS)

    Sevior, Martin; Fifield, Tom; Katayama, Nobuhiko

    2010-01-01

    The Belle II experiment which aims to increase the Luminosity of the KEKB collider by a factor of 50 will search for physics beyond the Standard Model through precision measurements and the investigation of rare processes in Flavour physics. The expected data rate is comparable to a current era LHC experiment with commensurate computing needs. Incorporating commercial cloud computing, such as that provided by the Amazon Elastic Compute Cloud (EC2) into the Belle II computing model may provide a lower Total Cost of Ownership for the Belle II computing solution. To investigate this possibility, we have created a system to conduct the complete Belle Monte Carlo simulation chain on EC2 to benchmark the cost and performance of the service. This paper will describe how this was achieved in addition to the drawbacks and costs of large-scale Monte Carlo production on EC2.

  7. Belle monte-carlo production on the Amazon EC2 cloud

    Energy Technology Data Exchange (ETDEWEB)

    Sevior, Martin; Fifield, Tom [University of Melbourne, School of Physics, Victoria 3010 Australia (Australia); Katayama, Nobuhiko, E-mail: msevior@gmail.co, E-mail: fifieldt@unimelb.edu.a, E-mail: nobu.katayama@kek.j [High Energy Accelerator Research Organisation (KEK), Tsukuba (Japan)

    2010-04-01

    The Belle II experiment which aims to increase the Luminosity of the KEKB collider by a factor of 50 will search for physics beyond the Standard Model through precision measurements and the investigation of rare processes in Flavour physics. The expected data rate is comparable to a current era LHC experiment with commensurate computing needs. Incorporating commercial cloud computing, such as that provided by the Amazon Elastic Compute Cloud (EC2) into the Belle II computing model may provide a lower Total Cost of Ownership for the Belle II computing solution. To investigate this possibility, we have created a system to conduct the complete Belle Monte Carlo simulation chain on EC2 to benchmark the cost and performance of the service. This paper will describe how this was achieved in addition to the drawbacks and costs of large-scale Monte Carlo production on EC2.

  8. Genes and proteins of Escherichia coli (GenProtEc).

    Science.gov (United States)

    Riley, M; Space, D B

    1996-01-01

    GenProtEc is a database of Escherichia coli genes and their gene products, classified by type of function and physiological role and with citations to the literature for each. Also present are data on sequence similarities among E.coli proteins with PAM values, percent identity of amino acids, length of alignment and percent aligned. The database is available as a PKZip file by ftp from mbl.edu/pub/ecoli.exe. The program runs under MS-DOS on IMB-compatible machines. GenProtEc can also be accessed through the World Wide Web at URL http://mbl.edu/html/ecoli.html.

  9. Integrated energy supply in closed distribution grids. On the legislator's scope in revising Article 110 of the Energy Economy Law with a mind to the third EC energy package; Integrierte Energieversorgung in geschlossenen Verteilernetzen. Zum Gestaltungsspielraum des Gesetzgebers zur Neuregelung des paragraph 110 EnWG im Lichte des Dritten EG-Energiepakets

    Energy Technology Data Exchange (ETDEWEB)

    Saecker, Franz Juergen; Wolf, Maik

    2009-07-01

    The general exemption of site networks from the regulatory provisions of the Energy Economy Law stipulated in its Article 110 has led to many distribution grids in Germany not being under the control of the regulatory authorities and therefore not being amenable to access or compensation regulations. The beneficiaries of this exemption have been facilities ranging from modern industrial parks, airports, railway stations to shopping centres and camping sites. However, in a decision on 22 May 2008 the European Court of Justice ruled with binding effect that the exceptions from EC law granted by Article 110 Section 1 No. 1 of the German Energy Economy Law were too far-reaching, and the provision is therefore no longer applicable. In Article 28 of the Electricity Directive and the Gas Directive the third EC energy package stipulates that EC member states may under certain conditions exempt closed distribution grids from the general regulations of ex ante price approval, but that for all other purposes such grids are amenable to the provisions of the regulation regime and to surveillance by the regulatory authorities. Thus site networks, too, will in future have to allow third parties access at reasonable terms (Articles 20, 21 of the Energy Economy Law).

  10. Permeation of Telone EC through protective gloves.

    Science.gov (United States)

    Zainal, Hanaa; Que Hee, Shane S

    2005-09-30

    Telone is a potent fumigant that is based on the chlorinated unsaturated hydrocarbon, 1,3-dichloropropene (1,3-DCP). It is often applied without dilution and so poses severe inhalation and air pollution threats. Urinary metabolites of 1,3-DCP have been detected after Telone skin exposure, so that preventing dermal exposure is also important. The objective of the study was to assess if nitrile and multi-layer ("laminated") gloves provide adequate protection against Telone EC formulation. To accomplish this, disposable (Safeskin) and chemically resistant (Sol-Vex) nitrile and laminated (Barrier mark and Silver Shield) glove materials were challenged by Telone EC with hexane liquid collection in an ASTM-type I-PTC-600 permeation cell. Analyses of cis- and trans-1,3-DCP in the collection fluid at specified times were performed on a moderately polar capillary column by gas chromatography-electron capture detection. Telone EC caused microholes in both nitrile materials, though the chemically protective material was degraded slower than the disposable nitrile. The laminated gloves offered limited protection. Silver Shield protected best because 1.5-2.3 mg 1,3-DCP permeated by 8 h relative to 2.5-7.6 mg for Barrier, implying about 2.5 times more protection for 8 h. Even for Silver Shield, the extent of protection was inadequate as illustrated by a risk assessment of the skin exposure situation. The normalized breakthrough times for both types of laminated gloves varied between 27 and 60 min. It is recommended that Viton gloves still be worn for protection.

  11. Phantom eye syndrome: types of visual hallucinations and related phenomena

    DEFF Research Database (Denmark)

    Roed Rasmussen, Marie Louise; Prause, Jan U; Johnson, Martin

    2009-01-01

    most often white or colored light, as a continuous sharp light or as moving dots. The most frequent triggers were darkness, closing of the eyes, fatigue, and psychological stress; 54% of patients had the experience more than once a week. Ten patients were so visually disturbed that it interfered...

  12. Blink patterns and lid-contact times in dry-eye and normal subjects

    Directory of Open Access Journals (Sweden)

    Ousler GW 3rd

    2014-05-01

    minute with their eyes closed, while normal subjects spent 0.7% of a minute with their eyes closed. Contact time might play a role in the visual function decay associated with increased blink rates.Keywords: keratoconjunctivitis sicca, dysfunctional tear syndrome, interblink interval, blink rate, visual function, visual tasks, diagnostic model, eyelid closures, microsleeps

  13. A closed-loop biorefining system to convert organic residues into fuels

    Science.gov (United States)

    Chen, Rui

    This project delivers an energy positive and water neutral, closed-loop biorefining system that converts organic wastes into renewable energy and reduces the overall impacts on the environment. The research consisted of three major stages: The first stage of this project was conducted in an anaerobic co-digestion system. Effects of the ratio of dairy manure-to-food waste as well as operating temperature were tested on the performance of the co-digestion system. Results illustrated an increase in biogas productivity with the increase of supplemental food waste; fiber analysis revealed similar chemical composition (cellulose, hemicellulose and lignin) of final solid digestate regardless their different initial feedstock blends and digestion conditions. The molecular genetic analyses demonstrated that anaerobic methanogenic microorganisms were able to adjust their community assemblage to maximize biogas production and produce homogenized solid digestate. The second stage utilized electrocoagulation (EC) pretreated liquid digestate from previous stage to culture freshwater algae. Kinetics study showed a similar maximum growth rate (0.201-0.207 g TS day-1) in both 2x and 5x dilutions of EC solution; however, the algal growth was inhibited in original EC solution (1x), possibly due to the high ammonia-to-phosphate ratio. Algal community assemblage changed drastically in different dilutions of EC solution after a 9-day culture. The following semi-continuous culture in 2x and 5x EC media established steady biomass productivities and nitrogen removal rates; in addition, both conditions illustrated a phenomenon of phosphorus luxury uptake. Biomass composition analyses showed that algae cultured in medium containing higher nitrogen (2x EC medium) accumulated more protein but less carbohydrate and lipid than the 5x EC medium. The last stage involved hydrolyzing the algal biomass cultured in anaerobic digestion effluent and analyzing the effects of the neutralized algal

  14. Regulatory competences of the EC in the energy sector; Regelungszustaendigkeiten der EG im Bereich Energie

    Energy Technology Data Exchange (ETDEWEB)

    Baur, J.F.; Blask, H. [Koeln Univ. (Germany). Inst. fuer das Recht der Europaeischen Gemeinschaften und Inst. fuer Energierecht

    2002-09-01

    In the light of necessary amendments of the Internal Electricity Market Directive and the Internal Gas Market Directive, a debate has evolved within the European Community about lawmaking powers for the energy sector. Whereas the Member States refer to the EC Treaty and deny any lawmaking powers of the EC for the energy sector, the EC defends its position that the EC should have and can derive lawmaking competence for energy policy decisions from the EC Treaty. The author reviews the situation from the legal point of view based on existing provisions and gives an outlook on a possible outcome of the ''constitutional convention'' of the EC which is to meet for discussing a revision of the EC Treaty. (orig./CB) [German] In Bezug auf die geplanten Aenderungen der Binnenmarktrichtlinien fuer Elektrizitaet und Gas werden moegliche Kompetenzen der EG im Bereich der Energiepolitik und ihre Grenzen eroertert. In einer Schlussbetrachtung werden die Ergebnisse zusammengefasst und ein kurzer Ausblick auf die Arbeit des 'Verfassungskonvents' der EU und die anstehende Vertragsrevision geworfen, in deren Rahmen die Implikation einer eigenstaendigen Spezialkompetenz im Bereich Energie erneut thematisiert werden koennte. (orig./CB)

  15. Electronic eye occluder with time-counting and reflection control

    Science.gov (United States)

    Karitans, V.; Ozolinsh, M.; Kuprisha, G.

    2008-09-01

    In pediatric ophthalmology 2 - 3 % of all the children are impacted by a visual pathology - amblyopia. It develops if a clear image isn't presented to the retina during an early stage of the development of the visual system. A common way of treating this pathology is to cover the better-seeing eye to force the "lazy" eye to learn seeing. However, children are often reluctant to wear such an occluder because they are ashamed or simply because they find it inconvenient. This fact requires to find a way how to track the regime of occlusion because results of occlusion is a hint that the actual regime of occlusion isn't that what the optometrist has recommended. We design an electronic eye occluder that allows to track the regime of eye occlusion. We employ real-time clock DS1302 providing time information from seconds to years. Data is stored in the internal memory of the CPU (EEPROM). The MCU (PIC16F676) switches on only if a mechanical switch is closed and temperature has reached a satisfactory level. The occlusion is registered between time moments when the infrared signal appeared and disappeared.

  16. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  17. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  18. The shift of energy regulatory powers under the framework of Directive 2009/72/EC

    International Nuclear Information System (INIS)

    Grimm, N. S.

    2011-01-01

    The paper examines the powers of Member States' national regulatory authorities under the framework of Directive 2009/72/EC of the European Parliament and of the Council of 13 July 2009 concerning common rules for the internal market in electricity and repealing Directive 2003/54/EC (OJEU L 176/37) and analyses the implications of framework of Directive 2009/72/EC on the national laws of the Member States, in particular on the Austrian and German constitutional, administrative and energy laws. The Introductory Part gives a historical overview of the development of national energy regulators under European energy legislation. This Part shows that the national regulatory authorities attract increased attention and that their regulatory powers are on a constant rise. In order to understand the huge impact of the framework of Directive 2009/72/EC on the regulatory regimes of the Member States, this Part briefly examines the former and current powers of the national energy regulators under Austrian and German law. Part Two analyses whether the powers conferred upon national energy regulators under the framework of Directive 2009/72/EC have been enhanced in comparison to those established under the framework of Directive 2003/54/EC. The main focus lies thereby on the propositions made by the European Commission in its Proposal for a Directive of the European Parliament and of the Council amending Directive 2003/54/EC concerning common rules for the internal market in electricity (COM (2007) 528 final, 2.1) and laid down in Directive 2009/72/EC. Part Two comes to the conclusion that the powers of the national energy regulators under the framework of Directive 2009/72/EC have indeed been enhanced in comparison to former regime of Directive 2003/54/EC. Part Three demonstrates that the enhancement of national energy regulators' powers does not benefit the Member States. On the contrary, they lose considerable powers of control over their own national energy regulators. While

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  1. Pengaruh Tingkat EC (Electrical Conductivity terhadap Pertumbuhan Tanaman Sawi (Brassica juncea L. pada Sistem Instalasi Aeroponik Vertikal

    Directory of Open Access Journals (Sweden)

    Pusdima Rahma Pratiwi

    2015-07-01

    Full Text Available Kebutuhan akan tanaman sawi semakin meningkat, sehingga diperlukan teknologi yang dapat memaksimalkan hasil serta memperbaiki teknik budidaya, salah satunya teknik budidaya aeroponik vertikal. Penelitian ini bertujuan untuk mengetahui respon pertumbuhan tanaman sawi yang terbaik terhadap pengaruh tingkat EC pada larutan nutrisi. Penelitian ini dilaksanakan di daerah Bekasi Timur dengan ketinggian 25 m di atas permukaan laut, dimulai pada bulan April 2014 sampai Juli 2014. Rancangan yang digunakan adalah Rancangan Acak Kelompok dengan 4 perlakuan yaitu A (Tingkat EC 1 mS cm-1, B (Tingkat EC 1,5 mS cm-1, C (Tingkat EC 2 mS cm-1, dan D (Tingkat EC 2,5 mS cm-1 dengan diulang sebanyak 4 kali. Hasil penelitian menunjukkan bahwa tingkat EC berpengaruh terhadap tinggi tanaman sawi pada umur 14 dan 18 hst, luas daun pada umur 26 dan 30 hst, panjang akar pada umur 30 hst, dan bobot basah pada umur 30 hst. Tingkat EC 2,5 mS cm-1 memberikan pengaruh baik terhadap bobot basah. The increasing need of mustard require technologies that can maximize result and improve cultivation, one of them is aeroponic vertical cultivation technique. This research aimed to know the best response of mustard growth on influence of nutrient EC level. This research was carried out in Bekasi Timur with altitude of 25 m above sea level, form April 2014 to July 2014. The design used was Randomized Block Design with 4 treatments that A (EC level 1 mS cm-1, B (EC level 1,5 mS cm-1, C (EC level 2 mS cm-1, and D (EC level  2,5 mS cm-1 with 4 replications. The results showed that EC level affected on plant height at 14 and 18 dap, leaf area at 26 and 30 dap, root length at 30 dap, and wet weight at the age of 30 dap. The EC level 2,5 mS cm-1had better effect on wet weight.

  2. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  3. Is eye damage caused by stereoscopic displays?

    Science.gov (United States)

    Mayer, Udo; Neumann, Markus D.; Kubbat, Wolfgang; Landau, Kurt

    2000-05-01

    A normal developing child will achieve emmetropia in youth and maintain it. Thereby cornea, lens and axial length of the eye grow astonishingly coordinated. In the last years research has evidenced that this coordinated growing process is a visually controlled closed loop. The mechanism has been studied particularly in animals. It was found that the growth of the axial length of the eyeball is controlled by image focus information from the retina. It was shown that maladjustment can occur by this visually-guided growth control mechanism that result in ametropia. Thereby it has been proven that e.g. short-sightedness is not only caused by heredity, but is acquired under certain visual conditions. It is shown that these conditions are similar to the conditions of viewing stereoscopic displays where the normal accommodation convergence coupling is disjoint. An evaluation is given of the potential of damaging the eyes by viewing stereoscopic displays. Concerning this, different viewing methods for stereoscopic displays are evaluated. Moreover, clues are given how the environment and display conditions shall be set and what users shall be chosen to minimize the risk of eye damages.

  4. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    Science.gov (United States)

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, pPRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, pPRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  5. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    Science.gov (United States)

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  6. [New determinations of the eye rotation center and criteria for the formation of its membrane in terms of the floating eye model and experimental support of the latter].

    Science.gov (United States)

    Galoian, V R

    1988-01-01

    It is well known that the eye is a phylogenetically stabilized body with rotation properties. The eye has an elastic cover and is filled with uniform fluid. According to the theory of covers and other concepts on the configuration of turning fluid mass we concluded that the eyeball has an elliptic configuration. Classification of the eyeball is here presented with simultaneous studies of the principles of the eye situation. The parallelism between the state and different types of heterophory and orthophory was studied. To determine normal configuration it is necessary to have in mind some principles of achieving advisable correct situation of the eye in orbit. We determined the centre of the eye rotation and showed that it is impossible to situate it out of the geometrical centre of the eyeball. It was pointed out that for adequate perception the rotation centre must be situated on the visual axis. Using the well known theory of floating we experimentally determined that the centre of the eye rotation lies on the level of the floating eye, just on the point of cross of the visual line with the optical axis. It was shown experimentally on the basis of recording the eye movements in the process of eyelid closing that weakening of the eye movements is of gravitational pattern and proceeds under the action of stability forces, which directly indicates the floating state of the eye. For the first time using the model of the floating eye it was possible to show the formation of extraeye vacuum by straining the back wall. This effect can be obtained without any difficulty, if the face is turned down. The role of negative pressure in the formation of the eye ametropy, as well as new conclusions and prognostications about this new model are discussed.

  7. The Influence of Eye Closure on Somatosensory Discrimination: A Trade-off Between Simple Perception and Discrimination.

    Science.gov (United States)

    Götz, Theresa; Hanke, David; Huonker, Ralph; Weiss, Thomas; Klingner, Carsten; Brodoehl, Stefan; Baumbach, Philipp; Witte, Otto W

    2017-06-01

    We often close our eyes to improve perception. Recent results have shown a decrease of perception thresholds accompanied by an increase in somatosensory activity after eye closure. However, does somatosensory spatial discrimination also benefit from eye closure? We previously showed that spatial discrimination is accompanied by a reduction of somatosensory activity. Using magnetoencephalography, we analyzed the magnitude of primary somatosensory (somatosensory P50m) and primary auditory activity (auditory P50m) during a one-back discrimination task in 21 healthy volunteers. In complete darkness, participants were requested to pay attention to either the somatosensory or auditory stimulation and asked to open or close their eyes every 6.5 min. Somatosensory P50m was reduced during a task requiring the distinguishing of stimulus location changes at the distal phalanges of different fingers. The somatosensory P50m was further reduced and detection performance was higher during eyes open. A similar reduction was found for the auditory P50m during a task requiring the distinguishing of changing tones. The function of eye closure is more than controlling visual input. It might be advantageous for perception because it is an effective way to reduce interference from other modalities, but disadvantageous for spatial discrimination because it requires at least one top-down processing stage. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Receptive fields for smooth pursuit eye movements and motion perception.

    Science.gov (United States)

    Debono, Kurt; Schütz, Alexander C; Spering, Miriam; Gegenfurtner, Karl R

    2010-12-01

    Humans use smooth pursuit eye movements to track moving objects of interest. In order to track an object accurately, motion signals from the target have to be integrated and segmented from motion signals in the visual context. Most studies on pursuit eye movements used small visual targets against a featureless background, disregarding the requirements of our natural visual environment. Here, we tested the ability of the pursuit and the perceptual system to integrate motion signals across larger areas of the visual field. Stimuli were random-dot kinematograms containing a horizontal motion signal, which was perturbed by a spatially localized, peripheral motion signal. Perturbations appeared in a gaze-contingent coordinate system and had a different direction than the main motion including a vertical component. We measured pursuit and perceptual direction discrimination decisions and found that both steady-state pursuit and perception were influenced most by perturbation angles close to that of the main motion signal and only in regions close to the center of gaze. The narrow direction bandwidth (26 angular degrees full width at half height) and small spatial extent (8 degrees of visual angle standard deviation) correspond closely to tuning parameters of neurons in the middle temporal area (MT). Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Mechanical eye injuries in children aged 0-15 years treated at the Clinic of Eye Diseases in Belgrade: Frequency, causes and preventive measures

    Directory of Open Access Journals (Sweden)

    Jovanović Miloš

    2013-01-01

    Full Text Available Introduction. Eye injuries represent a significant problem in children. Objective. The aim of the study was to determine the incidence and causes of the eye injury and to propose measures of the eye injury prevention in children up to 15 years of age. Methods. This was a retrospective study of 552 children with the eye injuries treated at the Clinic of Eye Diseases in Belgrade during the period March 1999 to February 2010. Gender and age of the children, time of injury, the type and site of injuries, visual acuity upon admission and at discharge, as well as the time of surgery in relation to time of injury were analyzed. Results. The ratio between the injured boys and girls was 3.6:1. The highest percentage of injured children was in the group 6-10 years old (39.7%; the injuries were almost evenly distributed according to months during the year and days during the week. The percentages of severe closed and open injuries of the eyeball were almost equal. Visual acuity upon discharge and subsequent follow-up examinations were significantly improved after the applied treatment in comparison with the visual acuity upon admission. Conclusion. Eye injuries in children still represent a severe health problem. Regarding the youngest age group of children, adults are mainly responsible for these injuries due to their lack of attention, while in older children these injuries are the result of the production and distribution of inappropriate toys and a failure to implement the legal traffic regulations applicable to children. The prevention of eye injuries is essential.

  10. Adaptation of the Emotional Contagion Scale (ECS and gender differences within the Greek cultural context

    Directory of Open Access Journals (Sweden)

    Damigos Dimitris

    2008-08-01

    Full Text Available Abstract Background The Emotional Contagion Scale (ECS is a self-report scale used to measure individual differences in susceptibility to converge towards the emotions expressed by others. The main aim of the present paper was to examine the psychometric properties of the Greek translation of the scale. Methods The Greek ECS was completed by 691 undergraduate students (312 males and 379 females. To investigate the factor structure of the ECS, principal components analysis (PCA was used. Results The results showed that a four-factor model was tenable. Regarding homogeneity, the Greek ECS version showed acceptable results for the full scale (α = 0.74 but not for all subscales. Gender differences were also identified concerning the susceptibility to emotional contagion between men and women. Women score significantly higher than men for all the different emotions described by the ECS (love, happiness, sadness except the anger emotion, where there was no significant difference. Conclusion The Greek version of the ECS showed good psychometric properties. It can be used to assess susceptibility to emotional contagion in correlation with psychopathological processes, mood and anxiety disorders primarily. The usefulness of the ECS in the fields of group psychotherapy and health psychology is also under consideration. Further investigation is needed in all these areas.

  11. Corneal epithelial cell viability of an ex vivo porcine eye model.

    Science.gov (United States)

    Chan, Ka Yin; Cho, Pauline; Boost, Maureen

    2014-07-01

    The aim was to assess the consistency of corneal epithelial cell viability of an ex vivo porcine eye model. Six porcine eye models (four test and two control) were prepared for each experiment. The model has a computer-controlled mechanical arm, which could move the eyelid of the porcine eye and apply phosphate buffered saline to simulate blinking and lacrimation. The four test eyes were set up to simulate evaporative dry eyes with simulated lacrimation and blinking (one blink and one drop of buffered saline per minute) over three hours. Control A models were set up to collect pre-experimental baseline data, while those of control B were the same as the test eyes but without lacrimation and blinking simulation. All porcine eyes were kept in a closed chamber with temperature and humidity well controlled. After three hours, the cells of all eyes (except control A, which were assessed immediately before commencement of the experiment) were assessed. The eyes were first dipped into 0.4 per cent trypan blue solution. Following the dissection and separation of the cells, the number of dead cells were then counted under the microscope with a field size of 0.25 mm(2). The experiment was repeated 11 times. No significant differences were found in the number of dead cells among the four test eyes in both the central and peripheral cornea. There were significantly more dead cells in the test eyes compared to control A but significantly less when compared to control B. More dead cells were found in the central cornea than the peripheral cornea in the test eyes but the difference was not observed in controls A and B. Epithelial cell viabilities among the four porcine eye models with simulated lacrimation and blinking were consistent. The majority of cells were viable before the experiment and simulated lacrimation and blinking maintained more viable cells over time. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  12. The upgrade of the DIII-D EC system using 120 GHz ITER gyrotrons

    International Nuclear Information System (INIS)

    Callis, R.W.; Lohr, J.; Gorelov, I.A.; Ponce, D.; Kajiwara, K.; Tooker, J.F.

    2005-01-01

    The planned growth in the EC system on DIII-D over the next few years requires the installation of two depressed collector gyrotrons, a high voltage power supply, two low loss transmission lines, and the required support equipment. This new DIII-D EC equipment could be made identical to the ITER EC system requirements. By building the DIII-D hardware to the ITER specifications, it will allow ITER to gain beneficial prototyping experience on a working tokamak, prior to committing to building the hardware for delivery to ITER

  13. Revisiting the EC/CMB model for extragalactic large scale jets

    Science.gov (United States)

    Lucchini, M.; Tavecchio, F.; Ghisellini, G.

    2017-04-01

    One of the most outstanding results of the Chandra X-ray Observatory was the discovery that AGN jets are bright X-ray emitters on very large scales, up to hundreds of kpc. Of these, the powerful and beamed jets of flat-spectrum radio quasars are particularly interesting, as the X-ray emission cannot be explained by an extrapolation of the lower frequency synchrotron spectrum. Instead, the most common model invokes inverse Compton scattering of photons of the cosmic microwave background (EC/CMB) as the mechanism responsible for the high-energy emission. The EC/CMB model has recently come under criticism, particularly because it should predict a significant steady flux in the MeV-GeV band which has not been detected by the Fermi/LAT telescope for two of the best studied jets (PKS 0637-752 and 3C273). In this work, we revisit some aspects of the EC/CMB model and show that electron cooling plays an important part in shaping the spectrum. This can solve the overproduction of γ-rays by suppressing the high-energy end of the emitting particle population. Furthermore, we show that cooling in the EC/CMB model predicts a new class of extended jets that are bright in X-rays but silent in the radio and optical bands. These jets are more likely to lie at intermediate redshifts and would have been missed in all previous X-ray surveys due to selection effects.

  14. Austria's environmental law in comparison with the environmental law of the EC

    International Nuclear Information System (INIS)

    Jantscher, S.H.

    1991-11-01

    The thesis describes and compares the environmental legislation in Austria and the EC. A short introduction into structure and organization of EC-institutions and EC-legislation in followed by an examination of the constitutional foundations of environmental policy in Austria and the EC respectively. After the adoption for the Single European Act, the EEC-Treaty provides for objectives, orientation criteria and instruments regarding environmental protection. These provisions constitute a valid basis for environmental action. The adoption of a constitutional law does equally declare environmental protection as an objective of the state in Austria, however, its significance is regarded as rather controversial. Some provinces ('Laender') have shown a higher degree of sensitivity in their constitutions . The distribution of powers between the EC and its member stated in the field of environmental protection is of particular interests. It is shown, that the principle of subsidiarity and the safeguard-clauses leave discretion to the member states. Much will be determined by the European Court of Justice (ECJ) . Main emphasis has been placed on the description and comparison of Austria's and the EEC-environmental legislation. Environmental legislation of Austria as well as the EC is outlined sector by sector (i.e. water, air, chemicals, waste, soil, fauna and flora) and subsequently the object of a detailed comparison. Criteria, such as - preventiveness -stringency - focus, depth and comprehensiveness - clearness and legal force of the regulations have been applied. For most of the mentioned sectors it is correct to state, that Austria's legislation is more preventive, advanced, comprehensive and stringent (especially regulations related to water, waste, chemicals, also air) . However, there are particular areas (e.g. air quality objectives, noise limits for construction plants) where Austria' s legislation may well get a fresh impetus

  15. Demonstration of sawtooth period control with EC waves in KSTAR plasma

    Directory of Open Access Journals (Sweden)

    Jeong J. H.

    2015-01-01

    Full Text Available The sawtooth period control in tokamak is important issue in recent years because the sawtooth crash can trigger TM/NTM instabilities and drive plasmas unstable. The control of sawtooth period by the modification of local current profile near the q=1 surface using ECCD has been demonstrated in a number of tokamaks [1, 2] including KSTAR. As a result, developing techniques to control the sawtooth period as a way of controlling the onset of NTM has been an important area of research in recent years [3]. In 2012 KSTAR plasma campaign, the sawtooth period control is carried out by the different deposition position of EC waves across the q=1 surface. The sawtooth period is shortened by on-axis co-ECCD (destabilization, and the stabilization of the sawtooth is also observed by off-axis co-ECCD at outside q=1 surface. In 2013 KSTAR plasma campaign, the sawtooth locking experiment with periodic forcing of 170 GHz EC wave is carried out to control the sawtooth period. The optimal target position which lengthens the sawtooth period is investigated by performing a scan of EC beam deposition position nearby q=1 surface at the toroidal magnetic field of 2.9 T and plasma current of 0.7 MA. The sawtooth locking by the modulated EC beam is successfully demonstrated as in [3-5] with the scan of modulation-frequency and duty-ratio at the low beta (βN~0.5 plasma. In this paper, the sawteeth behavior by the location of EC beam and the preliminary result of the sawtooth locking experiments in KSTAR will be presented.

  16. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  17. Process-engineering control valves under the EC codes; Steuerventile fuer die Prozesstechnik im Geltungsbereich der EG-Richtlinien

    Energy Technology Data Exchange (ETDEWEB)

    Gohlke, B. [IMI Norgren Herion Fluidtronic GmbH und Co. KG, Fellbach (Germany)

    2003-09-01

    The European Parliament and European Council have enacted special codes in order to implement uniform conditions in all countries of the European Community. The manufacturers of technical and commercial products are obliged to adhere to these codes. Harmonized standards, which are to be used as a tool for the implementation of the codes, are embedded at another level of the overall 'European reference literature'. Two EC codes, in particular, are definitive for fluids engineering: On the one hand, the EC Machinery Code, 98/37/EC and, on the other hand, the EC Pressurized Equipment Code, 97/23/EC. These EC codes cover, inter alia, machinery and chemical process-engineering plants, and conventional power generating plants. Norgren-Herion, a manufacturer of fluid engineering components, perceived a necessity for positioning its control valves in the scope of applicability of the EC codes. This article describes experience with the EC codes from the control valve manufacturer's point of view and examines the various qualification procedures for control valves. (orig.)

  18. Genes and proteins of Escherichia coli K-12 (GenProtEC).

    Science.gov (United States)

    Riley, M

    1997-01-01

    GenProtEC is a database of Escherichia coli genes and their gene products, classified by type of function and physiological role and with citations to the literature for each. Also present are data on sequence similarities amongE.coliproteins with PAM values, percent identity of amino acids, length of alignment and percent aligned. GenProtEC can also be accessed through the World Wide Web at URL http://mbl.edu/html/ecoli.html .

  19. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  20. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  1. Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.

    Science.gov (United States)

    Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K

    2010-02-01

    Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.

  2. EyeFrame: Real-time memory aid improves human multitasking via domain-general eye tracking procedures

    Directory of Open Access Journals (Sweden)

    P. eTaylor

    2015-09-01

    Full Text Available OBJECTIVE: We developed an extensively general closed-loop system to improve human interaction in various multitasking scenarios, with semi-autonomous agents, processes, and robots. BACKGROUND: Much technology is converging toward semi-independent processes with intermittent human supervision distributed over multiple computerized agents. Human operators multitask notoriously poorly, in part due to cognitive load and limited working memory. To multitask optimally, users must remember task order, e.g., the most neglected task, since longer times not monitoring an element indicates greater probability of need for user input. The secondary task of monitoring attention history over multiple spatial tasks requires similar cognitive resources as primary tasks themselves. Humans can not reliably make more than ~2 decisions/s. METHODS: Participants managed a range of 4-10 semi-autonomous agents performing rescue tasks. To optimize monitoring and controlling multiple agents, we created an automated short term memory aid, providing visual cues from users' gaze history. Cues indicated when and where to look next, and were derived from an inverse of eye fixation recency. RESULTS: Contingent eye tracking algorithms drastically improved operator performance, increasing multitasking capacity. The gaze aid reduced biases, and reduced cognitive load, measured by smaller pupil dilation. CONCLUSIONS: Our eye aid likely helped by delegating short-term memory to the computer, and by reducing decision making load. Past studies used eye position for gaze-aware control and interactive updating of displays in application-specific scenarios, but ours is the first to successfully implement domain-general algorithms. Procedures should generalize well to: process control, factory operations, robot control, surveillance, aviation, air traffic control, driving, military, mobile search and rescue, and many tasks where probability of utility is predicted by duration since last

  3. Do We Really Need to Wear Proper Eye Protection When Using Holmium:YAG Laser During Endourologic Procedures? Results from an Ex Vivo Animal Model on Pig Eyes.

    Science.gov (United States)

    Villa, Luca; Cloutier, Jonathan; Compérat, Eva; Kronemberg, Peter; Charlotte, Frederic; Berthe, Laurent; Rouchausse, Yann; Salonia, Andrea; Montorsi, Francesco; Traxer, Olivier

    2016-03-01

    We sought to evaluate the effect of holmium:yttrium-aluminum-garnet (Ho:YAG) laser exposure on ex vivo pig eyes and to test the protective action of different glasses in preventing eye lesions in case of accident. We pointed the tip of a Ho:YAG laser fiber from different distances (0, 3, 5, 8, 10, and 20 cm, respectively) toward the center of the pupil of the pig eye. The Ho:YAG laser was activated for 1 or 5 seconds at three different settings (0.5 J-20 Hz, 1 J-10 Hz, and 2 J-10 Hz, respectively). The experiment was repeated using laser safety glasses and eyeglasses. A total of 78 pig eyes were used. The effects of the Ho:YAG laser on pig eyes were assessed by histopathology. Comparable laser emission experiments were performed on thermal paper at different distances using different pulse energies. Ho:YAG laser-induced corneal lesions were observed in unprotected eyes, ranging from superficial burning lesions to full-thickness necrotic areas, and were directly related to pulse energy and time of exposure and inversely related to the distance from the eye. When the laser was placed 5 cm or more, no corneal damage was observed regardless of the laser setting and the time of exposure. Similar distance/energy level relationships were observed on thermal paper. No damage was observed to the lens or the retina in any of the Ho-YAG laser-treated eyes or in any of the eyes protected by laser safety and eyeglasses. Ho:YAG lasers can cause damage when set to high energy, but only to the cornea, from close distances (0-5 cm) and in the absence of eye protection. Eyeglasses are equally effective in preventing laser damage as laser safety glasses.

  4. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  5. Intra-session test-retest reliability of magnitude and structure of center of pressure from the Nintendo Wii Balance Board™ for a visually impaired and normally sighted population.

    Science.gov (United States)

    Jeter, Pamela E; Wang, Jiangxia; Gu, Jialiang; Barry, Michael P; Roach, Crystal; Corson, Marilyn; Yang, Lindsay; Dagnelie, Gislin

    2015-02-01

    Individuals with visual impairment (VI) have irreparable damage to one of the input streams contributing to postural stability. Here, we evaluated the intra-session test-retest reliability of the Wii Balance Board (WBB) for measuring Center of Pressure (COP) magnitude and structure, i.e. approximate entropy (ApEn) in fourteen legally blind participants and 21 participants with corrected-to-normal vision. Participants completed a validated balance protocol which included four sensory conditions: double-leg standing on a firm surface with eyes open (EO-firm); a firm surface with eyes closed (EC-firm); a foam surface with EO (EO-foam); and a foam surface with EC (EC-foam). Participants performed the full balance protocol twice during the session, separated by a period of 15min, to determine the intraclass correlation coefficient (ICC). Absolute reliability was determined by the standard error of measurement (SEM). The minimal difference (MD) was estimated to determine clinical significance for future studies. COP measures were derived from data sent by the WBB to a laptop via Bluetooth. COP scores increased with the difficulty of sensory condition indicating WBB sensitivity (all pbalance impairment among VI persons. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. EC Competition law and environmental protection

    Energy Technology Data Exchange (ETDEWEB)

    Rantala, M.

    1996-12-31

    Due to the increasing attention paid on environmental protection, by the European Community, the Member States and the consumers, undertakings are forced to adjust their policies to meet the new demands posed by public authorities and the market. This has an inevitable impact on competition. No matter how acceptable the goals were, the means are to be assessed also from the competition law point of view. The objective of this study is to analyze the situations where conflicts may take place, the main sources of research being the principles of law relating to the Treaty ,the judgements of the European Court of Justice, the Commission Decisions and other official documents of the Community as well as legal literature. This study classifies the Community and Member State instruments which are used for environmental protection into four categories. These are legislative, market-based, horizontal and financial supporting instruments. Undertakings` environmental practices, which are capable of affecting competition, are examined under Articles 85 and 86 EC, some attention being paid also to Article 90 EC. The touching points of competition policy and environmental protection in such cases are scrutinized under three headings. These are the two, in this case, most relevant public instruments, ie. legislative and market-based measures, and the voluntary actions of undertakings. (42 refs.)

  7. Enhanced CANDU 6 (EC6): a proven mid-sized reactor with fuel cycle capability

    International Nuclear Information System (INIS)

    Hopwood, J.; Soulard, M.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada (AECL) is finalizing development of the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and adds enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Changes are incremental and consistent with the CANDU 6 project approach. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; international markets are also being pursued. AECL is performing a comprehensive review of the EC6 design in the wake of the Fukushima accident, will review lessons learned, and incorporate any necessary improvements into new build design. (author)

  8. Enhanced CANDU 6 (EC6): a proven mid-sized reactor with fuel cycle capability

    International Nuclear Information System (INIS)

    Hopwood, J.; Soulard, M.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada (AECL) is finalizing development of the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Changes are incremental and consistent with the CANDU 6 project approach. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; international markets are also being pursued. AECL is performing a comprehensive review of the EC6 design in the wake of the Fukushima accident, will review lessons learned, and incorporate any necessary improvements into new build design. (author)

  9. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  11. Autologous serum eye drops for dry eye

    Science.gov (United States)

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  12. A Study on Partnering Mechanism in B to B EC Server for Global Supply Chain Management

    Science.gov (United States)

    Kaihara, Toshiya

    B to B Electronic Commerce (EC) technology is now in progress and regarded as an information infrastructure for global business. As the number and diversity of EC participants grows at the agile environment, the complexity of purchasing from a vast and dynamic array of goods and services needs to be hidden from the end user. Putting the complexity into the EC system instead means providing flexible auction server for enabling commerce within different business units. Market mechanism could solve the product distribution problem in the auction server by allocating the scheduled resources according to market prices. In this paper, we propose a partnering mechanism for B to B EC with market-oriented programming that mediates amongst unspecified various companies in the trade, and demonstrate the applicability of the economic analysis to this framework after constructing a primitive EC server. The proposed mechanism facilitates sophisticated B to B EC, which conducts a Pareto optimal solution for all the participating business units in the coming agile era.

  13. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  14. Expression of Finger Millet EcDehydrin7 in Transgenic Tobacco Confers Tolerance to Drought Stress.

    Science.gov (United States)

    Singh, Rajiv Kumar; Singh, Vivek Kumar; Raghavendrarao, Sanagala; Phanindra, Mullapudi Lakshmi Venkata; Venkat Raman, K; Solanke, Amolkumar U; Kumar, Polumetla Ananda; Sharma, Tilak Raj

    2015-09-01

    One of the critical alarming constraints for agriculture is water scarcity. In the current scenario, global warming due to climate change and unpredictable rainfall, drought is going to be a master player and possess a big threat to stagnating gene pool of staple food crops. So it is necessary to understand the mechanisms that enable the plants to cope with drought stress. In this study, effort was made to prospect the role of EcDehydrin7 protein from normalized cDNA library of drought tolerance finger millet in transgenic tobacco. Biochemical and molecular analyses of T0 transgenic plants were done for stress tolerance. Leaf disc assay, seed germination test, dehydration assay, and chlorophyll estimation showed EcDehydrin7 protein directly link to drought tolerance. Northern and qRT PCR analyses shows relatively high expression of EcDehydrin7 protein compare to wild type. T0 transgenic lines EcDehydrin7(11) and EcDehydrin7(15) shows superior expression among all lines under study. In summary, all results suggest that EcDehydrin7 protein has a remarkable role in drought tolerance and may be used for sustainable crop breeding program in other food crops.

  15. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  16. Greek mythology: the eye, ophthalmology, eye disease, and blindness.

    Science.gov (United States)

    Trompoukis, Constantinos; Kourkoutas, Dimitrios

    2007-06-01

    In distant eras, mythology was a form of expression used by many peoples. A study of the Greek myths reveals concealed medical knowledge, in many cases relating to the eye. An analysis was made of the ancient Greek texts for mythological references relating to an understanding of vision, visual abilities, the eye, its congenital and acquired abnormalities, blindness, and eye injuries and their treatment. The Homeric epics contain anatomical descriptions of the eyes and the orbits, and an elementary knowledge of physiology is also apparent. The concept of the visual field can be seen in the myth of Argos Panoptes. Many myths describe external eye disease ("knyzosis"), visual disorders (amaurosis), and cases of blinding that, depending on the story, are ascribed to various causes. In addition, ocular motility abnormalities, congenital anomalies (cyclopia), injuries, and special treatments, such as the "licking" method, are mentioned. The study of mythological references to the eye reveals reliable medical observations of the ancient Greeks, which are concealed within the myths.

  17. Ecological audits under EC regulations: background and impact in practice

    International Nuclear Information System (INIS)

    Walther, T.

    1995-01-01

    There are publications discussing the practical aspects of the implementation of the EC Directive on ecological audits, but little has been published yet on the theoretical background of the directive. The contribution in hand is intended to elucidate the theoretical basis of this instrument in the context of the system of law, explains the term of ''sustainable development'' as a key term, and reveals problems encountered in the evaluation of environmental performance. This information will contribute to a better understanding of the meaning and purposes of the EC Directive, and will thus point out ways and means for direct implementation. (orig.) [de

  18. Studies on absorption of EC waves in assisted startup experiment on FTU

    Science.gov (United States)

    Granucci, G.; Ricci, D.; Farina, D.; Figini, L.; Iraji, D.; Tudisco, O.; Ramponi, G.; Bin, W.

    2012-09-01

    Assistance of EC wave for plasma breakdown and current ramp up is the proposed scenario for the ITER case, characterized by low toroidal electric field. The experimental results on many tokamaks clearly indicate the capabilities of the proposed scheme to have a robust breakdown in ITER. The key aspect of this technique is the EC power required, strongly related to the absorption of the wave in the initial stage of plasma formation. This aspect is generally neglected due to the diagnostics difficulties in the plasma formation phase. As a consequence a multi-pass absorption scheme is usually considered reasonable, leading to a strong absorption after many reflections on the walls. The present study exploits the high temporal and spatial resolution of the fast scanning interferometer of FTU together with the measure of residual power obtained by a sniffer probe. The absorbed EC power is calculated considering also the polarization rotation and the subsequent mode conversion after incidence on the internal wall and compared with that derived from experimental data. The resulting EC power distribution can explain differences observed between perpendicular and oblique injection results, indicating future investigations to define ITER power requirements.

  19. Studies on absorption of EC waves in assisted startup experiment on FTU

    Directory of Open Access Journals (Sweden)

    Ramponi G.

    2012-09-01

    Full Text Available Assistance of EC wave for plasma breakdown and current ramp up is the proposed scenario for the ITER case, characterized by low toroidal electric field. The experimental results on many tokamaks clearly indicate the capabilities of the proposed scheme to have a robust breakdown in ITER. The key aspect of this technique is the EC power required, strongly related to the absorption of the wave in the initial stage of plasma formation. This aspect is generally neglected due to the diagnostics difficulties in the plasma formation phase. As a consequence a multi-pass absorption scheme is usually considered reasonable, leading to a strong absorption after many reflections on the walls. The present study exploits the high temporal and spatial resolution of the fast scanning interferometer of FTU together with the measure of residual power obtained by a sniffer probe. The absorbed EC power is calculated considering also the polarization rotation and the subsequent mode conversion after incidence on the internal wall and compared with that derived from experimental data. The resulting EC power distribution can explain differences observed between perpendicular and oblique injection results, indicating future investigations to define ITER power requirements.

  20. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  1. Upgrading from the Dicon Wiring Management system to IntEC at the Gentilly 2 station

    International Nuclear Information System (INIS)

    Theoret, P.A.

    1995-01-01

    The General Electric DICON Wiring Management system supplied to HQ during the construction of G2 is currently being replaced by the stand-alone version of the IntEC software developed by AECL. The reasons for replacing DICON and choosing lntEC are discussed. The different aspects of the two year DICON data conversion project are presented with the problems encountered and the means that were taken to resolve the problems. lntEC has shown our DICON data to be considerably more deficient than we had thought. This has increased the cost and the duration of the conversion process. However, correcting the errors during the conversion process provides us with much more accurate data. This should be viewed as an investment in configuration management. Many potential causes of future errors and potentially critical path delays have been removed. We have chosen to document the detailed procedures for the use of lntEC in our plant using a Windows Help File compiler. This also has been found to be extremely useful as a training tool as well as providing on-line help. The DICON data conversion into lntEC will not be completed until 1996. lntEC is not perfect. However, from what we have up to now, we are satisfied with the conviviality and efficiency of lntEC and with AECL's diligence in constantly aspiring in making it a better product. (author)

  2. Improved Balance Confidence and Stability for Elderly After 6 Weeks of a Multimodal Self-Administered Balance-Enhancing Exercise Program

    Science.gov (United States)

    Hafström, Anna; Malmström, Eva-Maj; Terdèn, Josefine; Fransson, Per-Anders; Magnusson, Måns

    2016-01-01

    Objective: To develop and assess the efficacy of a multimodal balance-enhancing exercise program (BEEP) designed to be regularly self-administered by community-dwelling elderly. The program aims to promote sensory reweighting, facilitate motor control, improve gaze stabilization, and stimulate continuous improvement by being constantly challenging. Method: Forty participants aged 60 to 80 years performed 6 weeks of BEEP training, on average for 16 min four times weekly, in a randomized one-arm crossover design. Results: One-leg standing time improved 32% with eyes open (EO), 206% with eyes closed (EC) on solid surface, and 54% EO on compliant surface (p balance improvements when perturbed on solid and compliant surfaces with EO and EC (p ≤ .033). Walking, step stool, and Timed Up and Go speeds increased (p ≤ .001), as did scores in Berg Balance and balance confidence scales (p ≤ .018). Discussion: Multimodal balance exercises offer an efficient, cost-effective way to improve balance control and confidence in elderly. PMID:28138495

  3. The effect of the Falcon 460 EC fungicide on soil microbial communities, enzyme activities and plant growth.

    Science.gov (United States)

    Baćmaga, Małgorzata; Wyszkowska, Jadwiga; Kucharski, Jan

    2016-10-01

    Fungicides are considered to be effective crop protection chemicals in modern agriculture. However, they can also exert toxic effects on non-target organisms, including soil-dwelling microbes. Therefore, the environmental fate of fungicides has to be closely monitored. The aim of this study was to evaluate the influence of the Falcon 460 EC fungicide on microbial diversity, enzyme activity and resistance, and plant growth. Samples of sandy loam with pH KCl 7.0 were collected for laboratory analyses on experimental days 30, 60 and 90. Falcon 460 EC was applied to soil in the following doses: control (soil without the fungicide), dose recommended by the manufacturer, 30-fold higher than the recommended dose, 150-fold higher than the recommended dose and 300-fold higher than the recommended dose. The observed differences in the values of the colony development index and the eco-physiological index indicate that the mixture of spiroxamine, tebuconazole and triadimenol modified the biological diversity of the analyzed groups of soil microorganisms. Bacteria of the genus Bacillus and fungi of the genera Penicillium and Rhizopus were isolated from fungicide-contaminated soil. The tested fungicide inhibited the activity of dehydrogenases, catalase, urease, acid phosphatase and alkaline phosphatase. The greatest changes were induced by the highest fungicide dose 300-fold higher than the recommended dose. Dehydrogenases were most resistant to soil contamination. The Phytotoxkit test revealed that the analyzed fungicide inhibits seed germination capacity and root elongation. The results of this study indicate that excessive doses of the Falcon 460 EC fungicide 30-fold higher than the recommended dose to 300-fold higher than the recommended dose) can induce changes in the biological activity of soil. The analyzed microbiological and biochemical parameters are reliable indicators of the fungicide's toxic effects on soil quality.

  4. Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeong-sik Seo

    2008-06-01

    Full Text Available Objective : This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results : 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn’t physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn’t eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions : I suggested that Bovis Calculus pharmacopuncture solution didn’t induced eye irritation in rabbits.

  5. Age-related changes and sex differences in postural control adaptability in children during periodic floor oscillation with eyes closed.

    Science.gov (United States)

    Fujiwara, Katsuo; Kiyota, Takeo; Mammadova, Aida; Yaguchi, Chie

    2011-01-01

    We investigated age-related changes and sex differences in adaptability of anticipatory postural control in children. Subjects comprised 449 children (4-12 years old) and 109 young adults (18-29 years old). Subjects stood with eyes closed on a force-platform fixed to a floor oscillator. We conducted five trials of 1-minute oscillation (0.5 Hz frequency, 2.5 cm amplitude) in the anteroposterior direction. Postural steadiness was quantified as the mean speed of the center of pressure in the anteroposterior direction (CoPy). In young adults, CoPy speed decreased rapidly until the third trial for both sexes. Adaptability was evaluated by changes in steadiness. The adaptability of children was categorized as "good," "moderate," and "poor," compared with a standard variation of the mean CoPy speed regression line between the first and fifth trials in young adults. Results were as follows: (1) anticipatory postural control adaptability starts to develop from age 6 in boys and 5 in girls, and greatly improves at age 7-8 in boys and 6 in girls; (2) the adaptability of children at age 11-12 (74% of boys and 63% of girls were categorized as "good") has not yet reached the same level as for young adults; (3) the adaptability at age 11-12 for girls is temporarily disturbed due to early puberty.

  6. MoisturEC: a new R program for moisture content estimation from electrical conductivity data

    Science.gov (United States)

    Terry, Neil; Day-Lewis, Frederick D.; Werkema, Dale D.; Lane, John W.

    2018-01-01

    Noninvasive geophysical estimation of soil moisture has potential to improve understanding of flow in the unsaturated zone for problems involving agricultural management, aquifer recharge, and optimization of landfill design and operations. In principle, several geophysical techniques (e.g., electrical resistivity, electromagnetic induction, and nuclear magnetic resonance) offer insight into soil moisture, but data‐analysis tools are needed to “translate” geophysical results into estimates of soil moisture, consistent with (1) the uncertainty of this translation and (2) direct measurements of moisture. Although geostatistical frameworks exist for this purpose, straightforward and user‐friendly tools are required to fully capitalize on the potential of geophysical information for soil‐moisture estimation. Here, we present MoisturEC, a simple R program with a graphical user interface to convert measurements or images of electrical conductivity (EC) to soil moisture. Input includes EC values, point moisture estimates, and definition of either Archie parameters (based on experimental or literature values) or empirical data of moisture vs. EC. The program produces two‐ and three‐dimensional images of moisture based on available EC and direct measurements of moisture, interpolating between measurement locations using a Tikhonov regularization approach.

  7. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    Science.gov (United States)

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  8. The role of eye protection in work-related eye injuries.

    Science.gov (United States)

    Fong, L P; Taouk, Y

    1995-05-01

    A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.

  9. The effect of intravitreal injections on dry eye, and proposed management strategies

    Directory of Open Access Journals (Sweden)

    Laude A

    2017-08-01

    Full Text Available Augustinus Laude,1–3 Jimmy WK Lim,1,2 Vishwanath Srinagesh,4 Louis Tong2,5–7 1National Healthcare Group Eye Institute, Tan Tock Seng Hospital, 2Singapore Eye Research Institute, 3Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore; 4Krieger Eye Institute, Baltimore, MD, USA; 5Singapore National Eye Centre, 6Duke NUS Medical School, 7Yong Loo Lin School of Medicine, National University of Singapore, Singapore Abstract: Intravitreal injection of anti-vascular endothelial growth factor (anti-VEGF agents has become a commonly used treatment method for a number of ophthalmic conditions, including age-related macular degeneration. Although anti-VEGF therapy has shown promising results for many patients, there are several aspects of its application that have not been thoroughly investigated. One of these is the development and/or escalation of concurrent dry eye syndrome. Many patients undergoing treatment are already predisposed to dry eye disease due to their age and overall ocular health. As dry eye can have a substantial impact on quality of life, it has become increasingly apparent that the clinical signs and symptoms should be closely monitored and aggressively managed. This will allow for the optimization of patient comfort and visual potential. Here, we discuss the reasons why dry eye may develop during the course of repeated ocular anti-VEGF therapy, highlighting the key concerns about current practices and proposing possible solutions to improve the outcome for the patients. Keywords: age-related macular degeneration, povidone–iodine, toxicity, ocular health, chronic ophthalmic treatment

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  11. Application of the EC eco-audit regulation in the energy industry

    International Nuclear Information System (INIS)

    Schulz, J.

    1994-01-01

    The eco-audit regulation isolates the precision of goals to improve operational environmental protection for observation, particularly with a view to the industrial energy economy. It is not wise without an investigation into the possible repercussions with other EU and national regulatory laws. Keywords here are: design of a heat application regulation according to the BImSchG, discussion over the introduction of an EC CO 2 Energy tax as well as the EC guidelines on reducing CO 2 emissions (SAVE). (orig./HP) [de

  12. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  13. Vibrating makes for better seeing: from the fly's micro eye movements to hyperacute visual sensors

    OpenAIRE

    Stéphane eViollet

    2014-01-01

    Active vision means that visual perception not only depends closely on the subject's own movements, but that these movements actually contribute to the visual perceptual processes. Vertebrates' and invertebrates' eye movements are probably part of an active visual process, but their exact role still remains to be determined. In this paper, studies on the retinal micro-movements occurring in the compound eye of the fly are reviewed. Several authors have located and identified the muscles invo...

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  15. Fractionated stereotactic irradiation by Cyberknife of choroid melanomas: repositioning validation, closed eyelids; Irradiation stereotaxique fractionnee par Cyberknife des melanomes choroidiens: validation du repositionnement, paupieres fermees

    Energy Technology Data Exchange (ETDEWEB)

    Horn, S.; Rezvoy, N.; Lacornerie, T.; Mirabel, X.; Labalette, P.; Lartigau, E. [Centre Oscar-Lambret, Service de Radiotherapie, 59 - Lille (France)

    2009-10-15

    The fractionated stereotactic radiotherapy by Cyberknife is an option in the treatment of eyes tumors. The advantages of the Cyberknife in the choroid melanomas are in its infra-millimetric precision, to the automated repositioning on the skull bones and to the conformity brought by the stereotaxy. The objective of this study was to validate the quality of repositioning and the immobility of the eyes with closed eyelids. Conclusion: the reproducibility of the eye positioning with closed eyelids seems enough to consider the conservative treatment of choroid melanomas by fractionated stereotactic radiotherapy by Cyberknife without implementation of fiducials nor retrobulbar anaesthesia. (N.C.)

  16. Association between dry eye symptoms and suicidal ideation in a Korean adult population.

    Science.gov (United States)

    Um, Sun-Bi; Yeom, Hyungseon; Kim, Na Hyun; Kim, Hyeon Chang; Lee, Hyung Keun; Suh, Il

    2018-01-01

    This study assessed the association of dry eyes with depression and suicidal ideation in a Korean adult population. Data from 16408 participants (6972 men and 9436 women) aged ≥ 19 years included in the fifth Korea National Health and Nutrition Examination Survey, conducted from 2010-2012, were analyzed. For dry eyes, surveys of previous diagnosis of dry eye disease (DED) by an ophthalmologist and experience of subjective dry eye symptoms were separately used. Diagnosis of depression and suicidal ideation were obtained via responses to an interviewer-assisted questionnaire, and questions were asked in a closed-ended response format. Logistic regression was used to examine the associations between dry eyes, depression, and suicidal ideation. DED diagnosis exhibited an odds ratio (OR) of 1.32 (95% confidence interval [CI] 1.11-1.57) for depression and 1.24 (95% CI 1.05-1.48) for suicidal ideation compared to those without DED, after adjusting for sex, age, education, occupation, household income, body mass index, smoking behavior, alcohol consumption, physical activity, hypertension, diabetes, dyslipidemia, thyroid diseases, major cardiovascular disease, and cancer. Similarly, the adjusted OR (95% CI) of dry eye symptoms was 1.50 (95% CI 1.30-1.73) for depression and 1.47 (95% CI 1.27-1.70) for suicidal ideation. Our findings suggest that dry eyes (either DED diagnosis or dry eye symptoms) may be associated with the prevalence of depression and suicidal ideation in the Korean adult population.

  17. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  18. The investigation of cytokine level in peripheral blood of patients with thyroid eye disease

    International Nuclear Information System (INIS)

    Yuan Wenhong; Zhang Yi; Luo Zhihang

    2008-01-01

    Objective: To detect the level of serum interleukin-6 (IL-6) and insulin-lide growth factor-1 (IGF-1) in patients with thyroid eye disease and to seek the relationship between serum level and the outbreak as well as the condition variety. Methods: To measure the level of serum IL-6 and IGF-1 by radioimmunoassay in 30 patients with thyroid eye disease after their clinical expression and activity score have been assessed, 30 patients with hyperthyroidism but without ophthalmopathy, 30 healthy subjects. Results: The level of serum IL-6 and IGF-1 in patients with thyroid eye disease were higher than that of patients with hyperthyroidism but without ophthalmopathy (t=4.20, t=4.00, P<0.01) and healthy subjects (t=4.20, t=4.05, P<0.01). IL-6 and IGF-1 levels tend to elevate with the increase of severity of eye disease. There were significant differences among them. Conclusion: The leve of IL-6, IGF-1 and the cause of thyroid eye disease are closely related, and IL-6 and IGF-1 levels in peripheral blood might reflect the severity of eye disease. (authors)

  19. Inactivation of the Ecs ABC transporter of Staphylococcus aureus attenuates virulence by altering composition and function of bacterial wall.

    Directory of Open Access Journals (Sweden)

    Ing-Marie Jonsson

    2010-12-01

    Full Text Available Ecs is an ATP-binding cassette (ABC transporter present in aerobic and facultative anaerobic gram-positive Firmicutes. Inactivation of Bacillus subtilis Ecs causes pleiotropic changes in the bacterial phenotype including inhibition of intramembrane proteolysis. The molecule(s transported by Ecs is (are still unknown.In this study we mutated the ecsAB operon in two Staphylococcus aureus strains, Newman and LS-1. Phenotypic and functional characterization of these Ecs deficient mutants revealed a defect in growth, increased autolysis and lysostaphin sensitivity, altered composition of cell wall proteins including the precursor form of staphylokinase and an altered bacterial surface texture. DNA microarray analysis indicated that the Ecs deficiency changed expression of the virulence factor regulator protein Rot accompanied by differential expression of membrane transport proteins, particularly ABC transporters and phosphate-specific transport systems, protein A, adhesins and capsular polysaccharide biosynthesis proteins. Virulence of the ecs mutants was studied in a mouse model of hematogenous S. aureus infection. Mice inoculated with the ecs mutant strains developed markedly milder infections than those inoculated with the wild-type strains and had consequently lower mortality, less weight loss, milder arthritis and decreased persistence of staphylococci in the kidneys. The ecs mutants had higher susceptibility to ribosomal antibiotics and plant alkaloids chelerythrine and sanguinarine.Our results show that Ecs is essential for staphylococcal virulence and antimicrobial resistance probably since the transport function of Ecs is essential for the normal structure and function of the cell wall. Thus targeting Ecs may be a new approach in combating staphylococcal infection.

  20. Inactivation of the Ecs ABC transporter of Staphylococcus aureus attenuates virulence by altering composition and function of bacterial wall.

    Science.gov (United States)

    Jonsson, Ing-Marie; Juuti, Jarmo T; François, Patrice; AlMajidi, Rana; Pietiäinen, Milla; Girard, Myriam; Lindholm, Catharina; Saller, Manfred J; Driessen, Arnold J M; Kuusela, Pentti; Bokarewa, Maria; Schrenzel, Jacques; Kontinen, Vesa P

    2010-12-02

    Ecs is an ATP-binding cassette (ABC) transporter present in aerobic and facultative anaerobic gram-positive Firmicutes. Inactivation of Bacillus subtilis Ecs causes pleiotropic changes in the bacterial phenotype including inhibition of intramembrane proteolysis. The molecule(s) transported by Ecs is (are) still unknown. In this study we mutated the ecsAB operon in two Staphylococcus aureus strains, Newman and LS-1. Phenotypic and functional characterization of these Ecs deficient mutants revealed a defect in growth, increased autolysis and lysostaphin sensitivity, altered composition of cell wall proteins including the precursor form of staphylokinase and an altered bacterial surface texture. DNA microarray analysis indicated that the Ecs deficiency changed expression of the virulence factor regulator protein Rot accompanied by differential expression of membrane transport proteins, particularly ABC transporters and phosphate-specific transport systems, protein A, adhesins and capsular polysaccharide biosynthesis proteins. Virulence of the ecs mutants was studied in a mouse model of hematogenous S. aureus infection. Mice inoculated with the ecs mutant strains developed markedly milder infections than those inoculated with the wild-type strains and had consequently lower mortality, less weight loss, milder arthritis and decreased persistence of staphylococci in the kidneys. The ecs mutants had higher susceptibility to ribosomal antibiotics and plant alkaloids chelerythrine and sanguinarine. Our results show that Ecs is essential for staphylococcal virulence and antimicrobial resistance probably since the transport function of Ecs is essential for the normal structure and function of the cell wall. Thus targeting Ecs may be a new approach in combating staphylococcal infection.

  1. Eye Tracker Accuracy: Quantitative Evaluation of the Invisible Eye Center Location

    OpenAIRE

    Wyder, Stephan; Cattin, Philippe C.

    2017-01-01

    Purpose. We present a new method to evaluate the accuracy of an eye tracker based eye localization system. Measuring the accuracy of an eye tracker's primary intention, the estimated point of gaze, is usually done with volunteers and a set of fixation points used as ground truth. However, verifying the accuracy of the location estimate of a volunteer's eye center in 3D space is not easily possible. This is because the eye center is an intangible point hidden by the iris. Methods. We evaluate ...

  2. Efficacy of topical cyclosporine 0.05% eye drops in the treatment of dry eyes

    OpenAIRE

    Haitham Y Al-Nashar

    2015-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of cyclosporine 0.05% in the treatment of dry-eye disease. Patients and methods A total of 35 eyes of 20 patients with dry-eye disease were included in the present study. Ten patients (20 eyes) had dry eyes associated with systemic rheumatologic disease (Sjögren′s syndrome), five patients (10 eyes) had dry eyes after undergoing laser in-situ keratomileusis, and five patients (five eyes) had dry eyes after cataract...

  3. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    Science.gov (United States)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  4. Burning Eye Syndrome: Do Neuropathic Pain Mechanisms Underlie Chronic Dry Eye?

    Science.gov (United States)

    Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Felix, Elizabeth R; Alegret, Ramon; Sarantopoulos, Constantine D

    2016-04-01

    Dry eye is a multi-factorial disorder that manifests with painful ocular symptoms and visual disturbances, which can only be partly attributed to tear dysfunction. This disorder may also involve neuroplasticity in response to neuronal injury. This review will emphasize the key characteristics of dry eye pain and its pathologic mechanisms, making the argument that a subset of dry eye represents a neuropathic pain disorder of the eye, more appropriately called "burning eye syndrome." A literature review was conducted using a PubMed search focusing on dry eye, corneal nociception, and neuropathic pain. Articles were reviewed and those discussing clinical course, pathophysiology, and neuronal regulation of chronic ocular pain as related to dry eye were summarized. We found that there is a discordance between ocular pain and dryness on the ocular surface. Although tear dysfunction may be one of the initial insults, its persistence may be associated with repeated ocular sensory nerve injury leading to an acute-to-chronic pain transition associated with neuropathologic changes (peripheral and central sensitization), neuronal dysfunction, and spontaneous ocular pain. Dry eye is becoming a major health concern due to its increasing incidence, significant morbidity, and economic burden. Recent evidence suggests that a subset of dry eye may be better represented as a chronic neuropathic pain disorder due to its features of dysesthesia, spontaneous pain, allodynia, and hyperalgesia. Future therapies targeted at the underlying neuroplasticity may yield improved efficacy for patients with this subset of dry eye, which we term "burning eye syndrome." © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  6. Provision of dosimeters by official monitoring services for eye lens dose estimation

    International Nuclear Information System (INIS)

    Engelhardt, J.; Martini, E.

    2013-01-01

    Recent epidemiological studies are implying that the radio sensitivity of the eye lens is much higher than supposed in the past. International recommendations and standards demand to lower down the annual limit of the eye lens organ dose to 20 mSv. Since about 10 years German monitoring services offer partial-body dosimeters fixed on the head or on glasses for monitoring the eye lens dose. These dosimeters are optimized to measure the (surface) personal dose equivalent H p (0,07) from 0,5 mSv up to 10 Sv, which clearly overestimate the organ dose of the eye lens. With special features like different calibrations partial-body dosimeters should be applicable for legal dosimetry to avoid the development of special H p (3) dosimeters. Accepting the right way for wearing these dosimeters it is important to get the right results. Practical experiences are shown with measuring results and the difficulties of rounding the exact measuring values to discrete dose steps. Closing this article we point to still missing legal basis and open questions regarding to type testing procedures. (orig.)

  7. Art Across The Curriculum: A (Not-So) Private Eye

    Science.gov (United States)

    Sartorius, Tara Cady

    2010-01-01

    Back in the 18th century, it was popular to give one's lover a locket containing a painted image of one's eye. Possibly this was a way of keeping privacy between two secret lovers. Or it may have been a way of keeping close to the gaze of a loved one while spending time apart. The pendants may have included a lock of hair or other tiny element…

  8. Usefulness of L,L-ethylenedicysteine - 99mTc complex (EC-99mTc) for the kidney investigations

    International Nuclear Information System (INIS)

    Surma, M.J.; Wiewiora, J.; Kapuscinksi, J.; Liniecki, J.

    1992-01-01

    To assess the usefulness of own EC- 99m Tc complex for the kidney function examination, the renoscintigraphy with EC- 99m Tc and clearance determinations were performed. During renoscintigraphy the kidney images were of superb quality, with overlaying organs (liver, spleen) not visualized. Renograms showed typical shapes, their TMAX and T1/2 values being insignificantly different from the obtained with other radiopharmaceuticals, used in renoscintigraphy (MAG 3 , hippuran). Very strict correlations were found between values of EC- 99m Tc and OIH- 131 I clearances (r=0.91) and excretion rate constants (r=0.92) of both radiopharmaceuticals. The correlation enabled formulation of an equation by which ERPF could be established from EC- 99m Tc clearance: ERPF OIH =1.245 x Cl EC +51.52. On the basis of this equation a lower boundary of the normal EC- 99m Tc clearance was established; it amounts to 300 ml/min/1.73 m 2 . (author). 17 refs, 5 figs, 1 tab

  9. Clear hydro-gel, compared to ointment, provides improved eye comfort after brief surgery

    NARCIS (Netherlands)

    Smolle, Michaela; Keller, Christian; Pinggera, Germar; Deibl, Martina; Rieder, Josef; Lirk, Philipp

    2004-01-01

    Anesthesia impairs lid closure and decreases tear secretion and stability. Protection may, in principle, be conveyed by manual eye closure, taping the eyelids closed, and by instillation of protective substances into the conjunctival sac. Both hydro-gels and ointments are used in clinical practice.

  10. Spatial and Temporal Variations of EC and OC Aerosol Combustion Sources in a Polluted Metropolitan Area

    Science.gov (United States)

    Mouteva, G.; Randerson, J. T.; Fahrni, S.; Santos, G.; Bush, S. E.; Ehleringer, J. R.; Czimczik, C. I.

    2015-12-01

    Anthropogenic emissions of carbonaceous aerosols are a major component of fine air particulate matter (PM2.5) in polluted metropolitan areas and in the global atmosphere. Elemental (EC) and organic carbon (OC) aerosols influence Earth's energy balance by means of direct and indirect pathways and EC has been suggested as a better indicator of public health impacts from combustion-related sources than PM mass. Quantifying the contribution of fossil fuel and biomass combustion to the EC and OC emissions and their temporal and spatial variations is critical for developing efficient legislative air pollution control measures and successful climate mitigation strategies. In this study, we used radiocarbon (14C) to separate and quantify fossil and biomass contributions to a time series of EC and OC collected at 3 locations in Salt Lake City (SLC). Aerosol samples were collected on quartz fiber filters and a modified OC/EC analyzer was used with the Swiss_4S protocol to isolate and trap the EC fraction. Together with the total carbon (TC) content of the samples, the EC was analyzed for its 14C content with accelerator mass spectrometry. The 14C of OC was derived as a mass balance difference between TC and EC. EC had an annual average fraction modern of 0.13±0.06 and did not vary significantly across seasons. OC had an annual average FM of 0.49±0.13, with the winter mean (0.43±0.11) lower than the summer mean (0.64±0.13) at the 5% significance level. While the 3 stations were chosen to represent a variety of environmental conditions within SLC, no major differences in this source partitioning were observed between stations. During winter, the major sources of air pollutants in SLC are motor vehicles and wood stove combustion and determining their relative contributions has been the subject of debate. Our results indicated that fossil fuels were the dominant source of carbonaceous aerosols during winter, contributing 87% or more of the total EC mass and 40-75% of the OC

  11. MoisturEC: A New R Program for Moisture Content Estimation from Electrical Conductivity Data.

    Science.gov (United States)

    Terry, Neil; Day-Lewis, Frederick D; Werkema, Dale; Lane, John W

    2018-03-06

    Noninvasive geophysical estimation of soil moisture has potential to improve understanding of flow in the unsaturated zone for problems involving agricultural management, aquifer recharge, and optimization of landfill design and operations. In principle, several geophysical techniques (e.g., electrical resistivity, electromagnetic induction, and nuclear magnetic resonance) offer insight into soil moisture, but data-analysis tools are needed to "translate" geophysical results into estimates of soil moisture, consistent with (1) the uncertainty of this translation and (2) direct measurements of moisture. Although geostatistical frameworks exist for this purpose, straightforward and user-friendly tools are required to fully capitalize on the potential of geophysical information for soil-moisture estimation. Here, we present MoisturEC, a simple R program with a graphical user interface to convert measurements or images of electrical conductivity (EC) to soil moisture. Input includes EC values, point moisture estimates, and definition of either Archie parameters (based on experimental or literature values) or empirical data of moisture vs. EC. The program produces two- and three-dimensional images of moisture based on available EC and direct measurements of moisture, interpolating between measurement locations using a Tikhonov regularization approach. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  12. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  13. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  14. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  15. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  16. Eye absence does not regulate planarian stem cells during eye regeneration

    OpenAIRE

    LoCascio, Samuel A.; Lapan, Sylvain W.; Reddien, Peter W.

    2017-01-01

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, ...

  17. Eye dose to staff involved in interventional and procedural fluoroscopy

    International Nuclear Information System (INIS)

    McLean, D; Hadaya, D; Tse, J

    2016-01-01

    In 2011 the International Commission on Radiological Protection (ICRP) lowered the occupational eye dose limit from 150 to 20 mSv/yr [1]. While international jurisdictions are in a process of adopting these substantial changes, medical physicists at the clinical level have been advising medical colleagues on specific situations based on dose measurements. Commissioned and calibrated TLDs mounted in commercially available holders designed to simulate the measurement of Hp(3), were applied to staff involved in x-ray procedures for a one month period. During this period clinical procedure data was concurrently collected and subject to audit. The use or not of eye personal protective equipment (PPE) was noted for all staff. Audits were conducted in the cardiac catheterisation laboratory, the interventional angiography rooms and the procedural room where endoscopic retrograde cholangiopancreatography (ERCP) procedures are performed. Significant levels of occupational dose were recorded in the cardiac and interventional procedures, with maximum reading exceeding the new limit for some interventional radiologists. No significant eye doses were measured for staff performing ERCP procedures. One outcome of the studies was increased use of eye PPE for operators of interventional equipment with increased availability also to nursing staff, when standing in close proximity to the patient during procedures. (paper)

  18. Comparison of two methods for composite score generation in dry eye syndrome.

    Science.gov (United States)

    See, Craig; Bilonick, Richard A; Feuer, William; Galor, Anat

    2013-09-19

    To compare two methods of composite score generation in dry eye syndrome (DES). Male patients seen in the Miami Veterans Affairs eye clinic with normal eyelid, corneal, and conjunctival anatomy were recruited to participate in the study. Patients filled out the Dry Eye Questionnaire 5 (DEQ5) and underwent measurement of tear film parameters. DES severity scores were generated by independent component analysis (ICA) and latent class analysis (LCA). A total of 247 men were included in the study. Mean age was 69 years (SD 9). Using ICA analysis, osmolarity was found to carry the largest weight, followed by eyelid vascularity and meibomian orifice plugging. Conjunctival injection and tear breakup time (TBUT) carried the lowest weights. Using LCA analysis, TBUT was found to be best at discriminating healthy from diseased eyes, followed closely by Schirmer's test. DEQ5, eyelid vascularity, and conjunctival injection were the poorest at discrimination. The adjusted correlation coefficient between the two generated composite scores was 0.63, indicating that the shared variance was less than 40%. Both ICA and LCA produced composite scores for dry eye severity, with weak to moderate agreement; however, agreement for the relative importance of single diagnostic tests was poor between the two methods.

  19. Selfish genetic elements and the gene’s-eye view of evolution

    Science.gov (United States)

    2016-01-01

    During the last few decades, we have seen an explosion in the influx of details about the biology of selfish genetic elements. Ever since the early days of the field, the gene’s-eye view of Richard Dawkins, George Williams, and others, has been instrumental to make sense of new empirical observations and to the generation of new hypotheses. However, the close association between selfish genetic elements and the gene’s-eye view has not been without critics and several other conceptual frameworks have been suggested. In particular, proponents of multilevel selection models have used selfish genetic elements to criticize the gene’s-eye view. In this paper, I first trace the intertwined histories of the study of selfish genetic elements and the gene’s-eye view and then discuss how their association holds up when compared with other proposed frameworks. Next, using examples from transposable elements and the major transitions, I argue that different models highlight separate aspects of the evolution of selfish genetic elements and that the productive way forward is to maintain a plurality of perspectives. Finally, I discuss how the empirical study of selfish genetic elements has implications for other conceptual issues associated with the gene’s-eye view, such as agential thinking, adaptationism, and the role of fitness maximizing models in evolution. PMID:29491953

  20. GPM GROUND VALIDATION ENVIRONMENT CANADA (EC) RADIOSONDE GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Environment Canada (EC) Radiosonde GCPEx dataset provides measurements of pressure, temperature, humidity, and winds collected by Vaisala...

  1. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  2. Eyes and ears: Using eye tracking and pupillometry to understand challenges to speech recognition.

    Science.gov (United States)

    Van Engen, Kristin J; McLaughlin, Drew J

    2018-05-04

    Although human speech recognition is often experienced as relatively effortless, a number of common challenges can render the task more difficult. Such challenges may originate in talkers (e.g., unfamiliar accents, varying speech styles), the environment (e.g. noise), or in listeners themselves (e.g., hearing loss, aging, different native language backgrounds). Each of these challenges can reduce the intelligibility of spoken language, but even when intelligibility remains high, they can place greater processing demands on listeners. Noisy conditions, for example, can lead to poorer recall for speech, even when it has been correctly understood. Speech intelligibility measures, memory tasks, and subjective reports of listener difficulty all provide critical information about the effects of such challenges on speech recognition. Eye tracking and pupillometry complement these methods by providing objective physiological measures of online cognitive processing during listening. Eye tracking records the moment-to-moment direction of listeners' visual attention, which is closely time-locked to unfolding speech signals, and pupillometry measures the moment-to-moment size of listeners' pupils, which dilate in response to increased cognitive load. In this paper, we review the uses of these two methods for studying challenges to speech recognition. Copyright © 2018. Published by Elsevier B.V.

  3. Plexiform neurofibroma of the eye region occurring in patients without neurofibromatosis type 1

    DEFF Research Database (Denmark)

    Bechtold, Dorte; Hove, Hanne D; Prause, Jan Ulrik

    2012-01-01

    The purpose of the present study was to investigate the correlation between Plexiform Neurofibroma (PN) of the eye region and Neurofibromatosis type 1 (NF1). According to the textbooks of ophthalmology, PN and NF1 are very closely linked. Our clinical experience raised doubts about this, however....

  4. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  5. Electrochemical reduction of graphited materials in LiClO{sub 4}-EC and LiClO{sub 4}-PC media: characterization of interface products by transmission electron microscopy; Reduction electrochimique de materiaux graphites en milieux LiCIO{sub 4}-EC et LiCIO{sub 4}-PC: caracterisation des produits d`interface par microscopie electronique a transmission

    Energy Technology Data Exchange (ETDEWEB)

    Billaud, D.; Naji, A.; Ghanbaja, J. [Universite Henri Poincare Nancy, 54 - Vandoeuvre-les-Nancy (France); Willmann, P. [Centre National d`Etudes Spatiales (CNES), 31 - Toulouse (France)

    1996-12-31

    The electrochemical intercalation of non-solvated lithium in different graphited materials has been performed in LiClO{sub 4}-ethylene carbonate (EC) medium. The irreversible capacity observed during the first output is mainly due to the formation of a passivation layer made of electrolyte reduction products. These products have been characterized for different electrode reduction potentials using transmission electron microscopy (image, diffraction) and electron energy loss spectroscopy (EELS). EC reduction on the electrode surface in presence of LiClO{sub 4} leads to the formation of Li{sub 2}CO{sub 3} for potentials close to 0.8 V vs Li{sup +}/Li. For lower potentials, the electrolyte reduction reaction goes on with the formation of different lithium alkyl-carbonates. In LiClO{sub 4}-propylene carbonate (PC) medium, the interface phenomena are different. The reduction of a graphite electrode is characterized by the exfoliation phenomenon which hinders lithium intercalation. On the contrary, the formation of the passivation layer by graphite reduction in LiClO{sub 4}-EC medium allows the cycling of the electrode in the LiClO{sub 4}-PC electrolyte. In this case, the irreversible capacity observed during the first output depends on the experimental conditions of formation of the passivation layer. Abstract only. (J.S.)

  6. Electrochemical reduction of graphited materials in LiClO{sub 4}-EC and LiClO{sub 4}-PC media: characterization of interface products by transmission electron microscopy; Reduction electrochimique de materiaux graphites en milieux LiCIO{sub 4}-EC et LiCIO{sub 4}-PC: caracterisation des produits d`interface par microscopie electronique a transmission

    Energy Technology Data Exchange (ETDEWEB)

    Billaud, D; Naji, A; Ghanbaja, J [Universite Henri Poincare Nancy, 54 - Vandoeuvre-les-Nancy (France); Willmann, P [Centre National d` Etudes Spatiales (CNES), 31 - Toulouse (France)

    1997-12-31

    The electrochemical intercalation of non-solvated lithium in different graphited materials has been performed in LiClO{sub 4}-ethylene carbonate (EC) medium. The irreversible capacity observed during the first output is mainly due to the formation of a passivation layer made of electrolyte reduction products. These products have been characterized for different electrode reduction potentials using transmission electron microscopy (image, diffraction) and electron energy loss spectroscopy (EELS). EC reduction on the electrode surface in presence of LiClO{sub 4} leads to the formation of Li{sub 2}CO{sub 3} for potentials close to 0.8 V vs Li{sup +}/Li. For lower potentials, the electrolyte reduction reaction goes on with the formation of different lithium alkyl-carbonates. In LiClO{sub 4}-propylene carbonate (PC) medium, the interface phenomena are different. The reduction of a graphite electrode is characterized by the exfoliation phenomenon which hinders lithium intercalation. On the contrary, the formation of the passivation layer by graphite reduction in LiClO{sub 4}-EC medium allows the cycling of the electrode in the LiClO{sub 4}-PC electrolyte. In this case, the irreversible capacity observed during the first output depends on the experimental conditions of formation of the passivation layer. Abstract only. (J.S.)

  7. Contributions from eye movement potentials to stimulus preceding negativity during anticipation of auditory stimulation

    DEFF Research Database (Denmark)

    Engdahl, Lis; Bjerre, Vicky K; Christoffersen, Gert R J

    2007-01-01

    Cognitive anticipation of a stimulus has been associated with an ERP called "stimulus preceding negativity" (SPN). A new auditory delay task without stimulus-related motor activity demonstrated a prefrontal SPN, present during attentive anticipation of sounds with closed eyes, but absent during d...

  8. Driver fatigue alarm based on eye detection and gaze estimation

    Science.gov (United States)

    Sun, Xinghua; Xu, Lu; Yang, Jingyu

    2007-11-01

    The driver assistant system has attracted much attention as an essential component of intelligent transportation systems. One task of driver assistant system is to prevent the drivers from fatigue. For the fatigue detection it is natural that the information about eyes should be utilized. The driver fatigue can be divided into two types, one is the sleep with eyes close and another is the sleep with eyes open. Considering that the fatigue detection is related with the prior knowledge and probabilistic statistics, the dynamic Bayesian network is used as the analysis tool to perform the reasoning of fatigue. Two kinds of experiments are performed to verify the system effectiveness, one is based on the video got from the laboratory and another is based on the video got from the real driving situation. Ten persons participate in the test and the experimental result is that, in the laboratory all the fatigue events can be detected, and in the practical vehicle the detection ratio is about 85%. Experiments show that in most of situations the proposed system works and the corresponding performance is satisfying.

  9. Perceptions of Eye Health and Eye Health Services among Adults Attending Outreach Eye Care Clinics in Papua New Guinea.

    Science.gov (United States)

    Burnett, Anthea; Yu, Mitasha; Paudel, Prakash; Naduvilath, Thomas; Fricke, Tim R; Hani, Yvonne; Garap, Jambi

    2015-01-01

    To determine how people attending outreach eye care clinics in Papua New Guinea (PNG) perceive eye health and eye health services. An interview-based questionnaire was administrated to a convenience sample of 614 adult participants across four provinces and perceptions of eye health and eye health services were recorded. Presenting and near visual acuity were measured and cause of visual impairment (VI) determined. In this sample, 113/614 participants (18.4%) presented with distance VI, 16 (2.6%) with distance blindness, and 221 (47.6%) with near VI. Older participants and those with near VI were more likely to indicate that it is hard to have an eye examination due to travel time, lack of transport and transport costs. Female participants and those from underserved areas were more likely to report shame and fear of jealousy from others when asked about their attitudes towards spectacles. Participants reporting that they were willing to pay higher amounts for testing and spectacles/treatment also reported higher education levels, higher household incomes and were more likely to be male. A quarter of participants (25.9%) indicated that they did not like having an eye examination because their reading and writing was poor. People attending outreach eye care clinics in PNG reported finding it difficult to attend eye health services due to transport difficulties and anticipated high costs. Negative attitudes towards spectacles were also prevalent, and negative perceptions appeared more frequently among older participants and those with less education.

  10. On the robustness of EC-PC spike detection method for online neural recording.

    Science.gov (United States)

    Zhou, Yin; Wu, Tong; Rastegarnia, Amir; Guan, Cuntai; Keefer, Edward; Yang, Zhi

    2014-09-30

    Online spike detection is an important step to compress neural data and perform real-time neural information decoding. An unsupervised, automatic, yet robust signal processing is strongly desired, thus it can support a wide range of applications. We have developed a novel spike detection algorithm called "exponential component-polynomial component" (EC-PC) spike detection. We firstly evaluate the robustness of the EC-PC spike detector under different firing rates and SNRs. Secondly, we show that the detection Precision can be quantitatively derived without requiring additional user input parameters. We have realized the algorithm (including training) into a 0.13 μm CMOS chip, where an unsupervised, nonparametric operation has been demonstrated. Both simulated data and real data are used to evaluate the method under different firing rates (FRs), SNRs. The results show that the EC-PC spike detector is the most robust in comparison with some popular detectors. Moreover, the EC-PC detector can track changes in the background noise due to the ability to re-estimate the neural data distribution. Both real and synthesized data have been used for testing the proposed algorithm in comparison with other methods, including the absolute thresholding detector (AT), median absolute deviation detector (MAD), nonlinear energy operator detector (NEO), and continuous wavelet detector (CWD). Comparative testing results reveals that the EP-PC detection algorithm performs better than the other algorithms regardless of recording conditions. The EC-PC spike detector can be considered as an unsupervised and robust online spike detection. It is also suitable for hardware implementation. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Damage Detection Response Characteristics of Open Circuit Resonant (SansEC) Sensors

    Science.gov (United States)

    Dudley, Kenneth L.; Szatkowski, George N.; Smith, Laura J.; Koppen, Sandra V.; Ely, Jay J.; Nguyen, Truong X.; Wang, Chuantong; Ticatch, Larry A.; Mielnik, John J.

    2013-01-01

    The capability to assess the current or future state of the health of an aircraft to improve safety, availability, and reliability while reducing maintenance costs has been a continuous goal for decades. Many companies, commercial entities, and academic institutions have become interested in Integrated Vehicle Health Management (IVHM) and a growing effort of research into "smart" vehicle sensing systems has emerged. Methods to detect damage to aircraft materials and structures have historically relied on visual inspection during pre-flight or post-flight operations by flight and ground crews. More quantitative non-destructive investigations with various instruments and sensors have traditionally been performed when the aircraft is out of operational service during major scheduled maintenance. Through the use of reliable sensors coupled with data monitoring, data mining, and data analysis techniques, the health state of a vehicle can be detected in-situ. NASA Langley Research Center (LaRC) is developing a composite aircraft skin damage detection method and system based on open circuit SansEC (Sans Electric Connection) sensor technology. Composite materials are increasingly used in modern aircraft for reducing weight, improving fuel efficiency, and enhancing the overall design, performance, and manufacturability of airborne vehicles. Materials such as fiberglass reinforced composites (FRC) and carbon-fiber-reinforced polymers (CFRP) are being used to great advantage in airframes, wings, engine nacelles, turbine blades, fairings, fuselage structures, empennage structures, control surfaces and aircraft skins. SansEC sensor technology is a new technical framework for designing, powering, and interrogating sensors to detect various types of damage in composite materials. The source cause of the in-service damage (lightning strike, impact damage, material fatigue, etc.) to the aircraft composite is not relevant. The sensor will detect damage independent of the cause

  12. Archive of Geosample Data and Information from the U.S. Extended Continental Shelf (ECS) Project.

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Geological samples collected as part of the U.S. Extended Continental Shelf (ECS) Project are curated by the U.S. Geological Survey, a partner in the ECS Project. To...

  13. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  14. ESCAPE: an integrated climate model for the EC

    International Nuclear Information System (INIS)

    Rotmans, J.

    1992-01-01

    A framework has been developed for the evaluation of policy options for climate change, called ESCAPE (Evaluation of Strategies to address Climate change by Adapting to and Preventing Emissions). ESCAPE consists of a suite of linked models which enables scenarios of greenhouse gas emissions to be constructed and their impact on global and regional climate and sea level and sectors of the European economy to be assessed. Conclusions resulting from simulations with the ESCAPE 1.1 model include: the major problem of a climate change for the EC is a sea level rise; Greece, Italy, Portugal and Spain will be faced with higher costs in the agricultural sector; worldwide implementation of an EC carbon tax leads to about 12% lower worldwide CO 2 emissions; to stabilize CO 2 emissions an Ecotax of 18 dollars per barrel would be required; and in all cases the rate of global temperature increase will be above the rate of 0.1 degree C per decade for the coming 40 years. 2 figs

  15. Business-to-business electronic commerce systems and services. Smart EC solution; Kigyoka nrenkei system solution system. Smart EC solution

    Energy Technology Data Exchange (ETDEWEB)

    Setoguchi, T.; Manchu, Y.; Katsumata, M. [Toshiba Corp., Tokyo (Japan)

    2000-04-01

    Toshiba provides a range of information technology (IT) solutions called SmartEC Solution, which includes business-to-business electronic commerce systems and services based on international standards and industrial know-how, especially our electronic data interchange (EDI) know-how as a manufacturer. These IT solutions are supplied as services covering strategy planning, system integration, and application service provider based on five types of business-to-business electronic commerce. (author)

  16. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  17. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life

    DEFF Research Database (Denmark)

    Rasmussen, Marie Louise Roed

    2010-01-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due...... to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. THE PURPOSE OF THE PHD THESIS WAS: To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique...... and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity...

  18. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    Directory of Open Access Journals (Sweden)

    J. J. Gu

    2006-01-01

    Full Text Available Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the control system to drive the artificial eye to move with the natural eye. The second generation model removes the impractical usage of the eye glass frame and uses the human brain EOG (electro-ocular-graph signal picked up by electrodes placed on the sides of a person's temple to carry out the same eye movement detection and control tasks as mentioned above. Theoretical issues on sensor failure detection and recovery, and signal processing techniques used in sensor data fusion, are studied using statistical methods and artificial neural network based techniques. In addition, practical control system design and implementation using micro-controllers are studied and implemented to carry out the natural eye movement detection and artificial robotic eye control tasks. Simulation and experimental studies are performed, and the results are included to demonstrate the effectiveness of the research project reported in this paper.

  19. Knowledge, Attitude, and Perception of Barriers for Eye Care among Diabetic Persons Registered at Employee Health Department of a Tertiary Eye Hospital of Central Saudi Arabia

    Science.gov (United States)

    Al-Alawi, Abeer; Al-Hassan, Arif; Chauhan, Deepti; Al-Futais, Muneera; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the level of knowledge, attitudes, and barriers to diabetic retinopathy (DR) screening among diabetic healthcare staff at a tertiary eye hospital in central Saudi Arabia. Methods: This was a descriptive survey using a closed-ended questionnaire. A. 5-grade. Likert scale was used for responses to each question. Data were collected on patient demographics and the status of diabetes. Survey responses related to knowledge, attitude, and barriers were grouped. Results: The study sample was comprised of 45 diabetics employed at the hospital. The mean age was 49 ± 11 years and 33 diabetics were males. One-third of the study population was referred to the eye clinic for DR screening. DR screening was performed in 25% of diabetics over the previous year. Twenty-nine (64%; 95% confidence intervals: 50–78) participants had excellent knowledge of eyecare for diabetic complications. Thirteen percent of participants had a positive attitude toward periodic eye checkups. Travel distance to an eyecare unit, no referral from family physicians for annual eye checkups and the lack of availability of gender-specific eyecare professionals were the main perceived barriers. Conclusion: Annual DR screening needs to be promoted to primary healthcare providers and diabetic patients. Barriers should be addressed to improve the uptake of DR screening. PMID:26957842

  20. Knowledge, Attitude, and Perception of Barriers for Eye Care among Diabetic Persons Registered at Employee Health Department of a Tertiary Eye Hospital of Central Saudi Arabia.

    Science.gov (United States)

    Al-Alawi, Abeer; Al-Hassan, Arif; Chauhan, Deepti; Al-Futais, Muneera; Khandekar, Rajiv

    2016-01-01

    To evaluate the level of knowledge, attitudes, and barriers to diabetic retinopathy (DR) screening among diabetic healthcare staff at a tertiary eye hospital in central Saudi Arabia. This was a descriptive survey using a closed-ended questionnaire. A. 5-grade. Likert scale was used for responses to each question. Data were collected on patient demographics and the status of diabetes. Survey responses related to knowledge, attitude, and barriers were grouped. The study sample was comprised of 45 diabetics employed at the hospital. The mean age was 49 ± 11 years and 33 diabetics were males. One-third of the study population was referred to the eye clinic for DR screening. DR screening was performed in 25% of diabetics over the previous year. Twenty-nine (64%; 95% confidence intervals: 50-78) participants had excellent knowledge of eyecare for diabetic complications. Thirteen percent of participants had a positive attitude toward periodic eye checkups. Travel distance to an eyecare unit, no referral from family physicians for annual eye checkups and the lack of availability of gender-specific eyecare professionals were the main perceived barriers. Annual DR screening needs to be promoted to primary healthcare providers and diabetic patients. Barriers should be addressed to improve the uptake of DR screening.

  1. Does sound structure affect word learning? An eye-tracking study of Danish learning toddlers

    DEFF Research Database (Denmark)

    Trecca, Fabio; Bleses, Dorthe; Madsen, Thomas O.

    2018-01-01

    closely related languages. In support of this hypothesis, recent work has shown that the phonetic properties of Danish negatively affect online language processing in young Danish children. In this study, we used eye-tracking to investigate whether the challenges associated with processing Danish also...

  2. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  3. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  4. Lunar Module ECS (Environmental Control System) - Design Considerations and Failure Modes. Part 1

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    Design considerations and failure modes for the Lunar Module (LM) Environmental Control System (ECS) are described. An overview of the the oxygen supply and cabin pressurization, atmosphere revitalization, water management and heat transport systems are provided. Design considerations including reliability, flight instrumentation, modularization and the change to the use of batteries instead of fuel cells are discussed. A summary is provided for the LM ECS general testing regime.

  5. Experimental Study on Performance of EC-120 Wet-mixing Modified Asphalt Cementing Materials%EC-120温拌改性沥青胶结料性能试验研究

    Institute of Scientific and Technical Information of China (English)

    周刚; 唐江; 谭昆华; 谭巍

    2012-01-01

    This paper carries out experimental study on rotational viscosity, normal performance indices and rheological properties, etc. of EC-120 organic viscosity reducing and wet-mixing modified asphalt, the experiment shows that EC-120 as an organic additive with the melting point at approximate 100 t is well compatible with asphalt and easy to prepare without problem of isolation. The experiment also shows EC-120 in wet-mixing modified asphalt can reduce high-temperature viscosity and increase medium and low-temperature viscosity of asphalt so as to decrease mixing and compacting temperature of asphalt mixtures; can reduce needle penetration and increase softening point and anti-rutting factor so as to improve high-temperature stability of asphalt remarkably; and will enable reduction of ductility, increase of fatigue factor, increase of creepage stiffness and reduction of deformation rate of wet-mixing modified asphalt, which slightly have negative influence on anti-fatigue and low-temperature cracking properties of asphalt.%对EC-120有机降粘温拌改性沥青进行旋转粘度、常规性能指标、流变特性等试验研究,试验表明,EC- 120作为一种熔点在100℃左右的有机添加剂,与沥青相容性好,制备容易,不存在离析问题.试验还表明在温拌改性沥青中,EC-120可降低沥青的高温粘度,提高中低温粘度,从而降低沥青混合料的拌和和压实温度;可降低沥青针入度,提高软化点和抗车辙因子,从而大幅改善沥青的高温稳定性;会使温拌改性沥青的延度降低,疲劳因子增大,蠕变劲度增大,变形速率减小,对沥青的抗疲劳和低温抗开裂性能略有消极影响.

  6. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  7. Herpetic Eye Disease in a Public Eye Hospital in Nigeria | Nwosu ...

    African Journals Online (AJOL)

    Objective: To determine the aetiology, pattern and complications of herpetic eye disease seen at the Guinness Eye Centre, Onitsha, Nigeria. Materials and Methods: The case files of all patients with herpetic eye disease who presented at the centre between January 1998 and December 2003 were reviewed. Information on ...

  8. Normal human serum (HS) prevents oxidant-induced lysis of cultured endothelial cells (ECs)

    International Nuclear Information System (INIS)

    Callahan, K.S.; Harlan, J.M.

    1986-01-01

    Most studies demonstrating oxidant lysis of cultured ECs are performed in serum-free media or media containing low concentrations of bovine serum. The authors found that HS protects human and bovine ECs from lysis caused by reagent H 2 O 2 or glucose/glucose oxidase (GO)-generated H 2 O 2 . EC injury was assessed by 51 Cr release, cell detachment, or trypan blue dye exclusion. Protective HS activity was dose-dependent with concentrations greater than or equal to 25% preventing lethal injury. Cytotoxicity at 24 hrs, induced by 20 mU/ml GO, was 90.1 +/- 5.2% without HS vs 1.7 +/- 4.6% with 25% HS present (20 exp). Similar protection was observed with heparinized plasma. Of note, comparable concentrations of bovine serum were devoid of protective activity. Addition of fatty acid-free albumin to the media was also without protective effect. Preliminary characterization showed HS activity was stable to 60 0 C for 30 min, non-dialyzable at 25,000 MW cutoff, and retained in delipidated serum. The HS protection was not merely due to scavenging of exogenous H 2 O 2 as A23187-induced EC lysis was also prevented by HS. Protective activity was not reproduced by purified cerruloplasmin or transferrin. In conclusion, unidentified factor(s) present in HS protect cultured ECs from oxidant-induced lysis. Since endothelium is normally exposed to 100% plasma, the authors suggest that in vitro studies of oxidant-mediated injury be performed in the presence of HS. Factor(s) in HS may play an important role in modulating oxidant-induced vascular injury in vivo

  9. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  10. Patient satisfaction regarding eye care services at tertiary hospital of central India

    Directory of Open Access Journals (Sweden)

    Anand Sudhan

    2011-01-01

    Study Design : Descriptive study. Materials and Methods : This study was conducted between September 2005 and June 2006. Patients attending the eye clinic of Sadguru Netra Chikitsalaya, Chitrakoot, Madhya Pradesh, India, and admitted as in-patients in this hospital were our study population. Randomly selected patients were interviewed by trained staff. Close-ended questionnaire was used to conduct these structured interviews. Their responses were grouped into one of five categories and evaluated to determine satisfaction for different components of eye care services. Results : Three hundred and twenty persons were interviewed. The satisfaction was of excellent grade among 77 (48.1% patients attending clinic and 156 (97.5% patients who were admitted in the hospital. The participants expressed dissatisfaction for the long waiting period in clinics, poor cleanliness, and insufficient toilet facilities. Those admitted in the hospital felt that food facilities were less than the expected quality. Child-friendly facilities received high satisfaction scores. Conclusion : Although eye care services both in clinics and in the wards were satisfactory according to the end-users, there are scopes for improvement. Patient satisfaction surveys should be encouraged in hospitals for better accountability and also for strengthening the quality of eye care services.

  11. Degeneration of rapid eye movement sleep circuitry underlies rapid eye movement sleep behavior disorder.

    Science.gov (United States)

    McKenna, Dillon; Peever, John

    2017-05-01

    During healthy rapid eye movement sleep, skeletal muscles are actively forced into a state of motor paralysis. However, in rapid eye movement sleep behavior disorder-a relatively common neurological disorder-this natural process is lost. A lack of motor paralysis (atonia) in rapid eye movement sleep behavior disorder allows individuals to actively move, which at times can be excessive and violent. At first glance this may sound harmless, but it is not because rapid eye movement sleep behavior disorder patients frequently injure themselves or the person they sleep with. It is hypothesized that the degeneration or dysfunction of the brain stem circuits that control rapid eye movement sleep paralysis is an underlying cause of rapid eye movement sleep behavior disorder. The link between brain stem degeneration and rapid eye movement sleep behavior disorder stems from the fact that rapid eye movement sleep behavior disorder precedes, in the majority (∼80%) of cases, the development of synucleinopathies such as Parkinson's disease, dementia with Lewy bodies, and multiple system atrophy, which are known to initially cause degeneration in the caudal brain stem structures where rapid eye movement sleep circuits are located. Furthermore, basic science and clinical evidence demonstrate that lesions within the rapid eye movement sleep circuits can induce rapid eye movement sleep-specific motor deficits that are virtually identical to those observed in rapid eye movement sleep behavior disorder. This review examines the evidence that rapid eye movement sleep behavior disorder is caused by synucleinopathic neurodegeneration of the core brain stem circuits that control healthy rapid eye movement sleep and concludes that rapid eye movement sleep behavior disorder is not a separate clinical entity from synucleinopathies but, rather, it is the earliest symptom of these disorders. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and

  12. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    Directory of Open Access Journals (Sweden)

    Xiangjun Chen

    Full Text Available PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs were calculated. Univariate analysis of covariance (ANCOVA was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP, central corneal thickness (CCT and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90 in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88. The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05 and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05 in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05 and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05. CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  13. The JCMT Transient Survey: Detection of Submillimeter Variability in a Class I Protostar EC 53 in Serpens Main

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hyunju; Cho, Jungyeon [Department of Astronomy and Space Science, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134 (Korea, Republic of); Lee, Jeong-Eun [School of Space Research, Kyung Hee University, 1732, Deogyeong-Daero, Giheung-gu Yongin-shi, Gyunggi-do 17104 (Korea, Republic of); Mairs, Steve; Johnstone, Doug [Department of Physics and Astronomy, University of Victoria, Victoria, BC, V8P 1A1 (Canada); Herczeg, Gregory J. [Kavli Institute for Astronomy and Astrophysics, Peking University, Yiheyuan 5, Haidian Qu, 100871 Beijing (China); Kang, Sung-ju; Kang, Miju, E-mail: jeongeun.lee@khu.ac.kr [Korea Astronomy and Space Science Institute, 776 Daedeokdae-ro, Yuseong-gu, Daejeon 34055 (Korea, Republic of); Collaboration: JCMT Transient Team

    2017-11-01

    During the protostellar phase of stellar evolution, accretion onto the star is expected to be variable, but this suspected variability has been difficult to detect because protostars are deeply embedded. In this paper, we describe a submillimeter luminosity burst of the Class I protostar EC 53 in Serpens Main, the first variable found during our dedicated JCMT/SCUBA-2 monitoring program of eight nearby star-forming regions. EC 53 remained quiescent for the first six months of our survey, from 2016 February to August. The submillimeter emission began to brighten in 2016 September, reached a peak brightness of 1.5 times the faint state, and has been decaying slowly since 2017 February. The change in submillimeter brightness is interpreted as dust heating in the envelope, generated by a luminosity increase of the protostar of a factor of ≥4. The 850 μ m light curve resembles the historical K -band light curve, which varies by a factor of ∼6 with a 543 period and is interpreted as accretion variability excited by interactions between the accretion disk and a close binary system. The predictable detections of accretion variability observed at both near-infrared and submillimeter wavelengths make the system a unique test-bed, enabling us to capture the moment of the accretion burst and to study the consequences of the outburst on the protostellar disk and envelope.

  14. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  15. Choosing Wisely When It Comes to Eye Care: Antibiotics for Eye Injections

    Science.gov (United States)

    ... Antibiotics for eye injections; and Punctal plugs for dry eye . This is the fourth in a series of ... why patients and their ophthalmologists should discuss treating dry eye with punctal plugs only after other treatment options ...

  16. Test of ring, eye lens and whole body dosemeters for the dose quantity Hp(3) to be used in interventional radiology

    Science.gov (United States)

    Szumska, A.; Budzanowski, M.; Kopeć, R.

    2017-11-01

    In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).

  17. Spectacle-related eye injuries, spectacle-impact performance and eye protection.

    Science.gov (United States)

    Hoskin, Annette K; Philip, Swetha; Dain, Stephen J; Mackey, David A

    2015-05-01

    The aim was to review the prevalence of spectacle-related ocular trauma and the performance of currently available spectacle materials and to identify the risk factors associated with spectacle-related ocular trauma. A literature review was conducted using Medline, Embase and Google with the keywords 'eyeglasses' OR 'spectacles' AND 'ocular injury' / 'eye injury'/ 'eye trauma' / 'ocular trauma'. Articles published prior to 1975 were excluded from this review because of advances in spectacle lens technology and Food and Drug Administration legislative changes requiring impact resistance of all prescription spectacle lenses in the United States. Six hundred and ninety-five individual ocular traumas, for which spectacles contributed to or were the main cause of injury, were identified in the literature. Eye injuries occurred when spectacles were worn in sports, in which medium- to high-impact energies were exerted from balls, racquets or bats and/or as a result of a collision with another player. Frame, lens design and product material choice were found to be associated with ocular injury, with polycarbonate lenses cited as the material of choice in the literature. International, regional and national standards for spectacle lenses had a wide range of impact requirements for prescription spectacle lenses, sports eye protection and occupational eye protection. Spectacle-related injury represents a small but preventable cause of ocular injury. With the increasing numbers of spectacle wearers and calls to spend more time outdoors to reduce myopia, spectacle wearers need to be made aware of the potential risks associated with wearing spectacles during medium- to high-risk activities. At particular risk are those prone to falls, the functionally one-eyed, those who have corneal thinning or have had previous eye surgery or injury. With increased understanding of specific risk factors, performance guidelines can be developed for prescription spectacle eye

  18. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    OpenAIRE

    J. J. Gu; M. Meng; A. Cook; P. X. Liu

    2006-01-01

    Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the contro...

  19. Development of EC technology in JAERI

    International Nuclear Information System (INIS)

    Sakamoto, Keishi; Takahashi, Koji; Kasugai, Atsushi; Hayashi, Kenichi; Ikeda, Yoshitaka; Kajiwara, Ken; Fujii, Tsuneyuki; Imai, Tsuyoshi; Kariya, Tsuyoshi; Mitsunaka, Yoshika

    2003-01-01

    Recent progress of electron cyclotron (EC) heating and current drive technologies in JAERI is reported. In 170 GHz gyrotron development, 0.9 MW/9.2 sec (efficiency: 43%), 0.5 MW/30 sec (46%), etc, have been demonstrated. As for 110 GHz gyrotron, 1 MW/5 sec and 1.2 MW/4.1 sec were obtained. Using four 110 GHz gyrotrons, a 3 MW power injection into JT- 60U plasma was carried out. In parallel, a launcher design and its development that includes neutron irradiation of the launcher components and a remote steering launcher are underway for ITER application. (authors)

  20. System and Method for Eye Tracking

    DEFF Research Database (Denmark)

    2017-01-01

    A method and system for monitoring the motion of one or both eyes, includes capturing a sequence of overlapping images of a subject's face including an eye and the corresponding non-eye region; identifying a plurality of keypoints in each image; mapping corresponding keypoints in two or more images...... of the sequence; assigning the keypoints to the eye and to the corresponding non-eye region; calculating individual velocities of the corresponding keypoints in the eye and the corresponding non-eye region to obtain a distribution of velocities; extracting at least one velocity measured for the eye and at least...... one velocity measured for the corresponding non-eye region; calculating the eye-in-head velocity for the eye based upon the measured velocity for the eye and the measured velocity for the corresponding non-eye region; and calculating the eye-in-head position based upon the eye- in-head velocity....

  1. On- and off-eye spherical aberration of soft contact lenses and consequent changes of effective lens power.

    Science.gov (United States)

    Dietze, Holger H; Cox, Michael J

    2003-02-01

    Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.

  2. Organization of eye bank

    International Nuclear Information System (INIS)

    Reddy, S.C.

    1999-01-01

    Comeal transplantation is the only method of combating the blindness due to corneal opacity caused by infections, malnutrition, trauma and hereditary diseases. Comeal blindness is more prevalent in the developing countries. The availability of the donor cornea, trained ophthalmic surgeons and microsurgery facilities are the key factors in restoring vision in-patients with comeal blindness. The eye bank organization is somewhat similar to that of blood bank. The eye bank should be located in a hospital or a medical centre in which a laboratory may be established for the evaluation and storage of donor tissue. The medical director (Ophthalmologist), technician, secretary and public relation officer are the persons who play an important role in the successful organization of eye bank. The function of the eye bank are procurement, assessment, processing, distribution of donor eyes/corneas, training of technicians/doctors, and conducting research related to storage of donor tissue and corneal transplantation. The necessary infrastructure required for the organization of an eye bank include separate accommodation area for the personnel and the laboratory, telephone, computer, refrigerator, laminar air flow hood. Slitlamp, specular microscope, storage media and equipment, instrument for enucleation of donor eyes, and a motor vehicle. The details of responsibilities of the staff of eye bank, source of donor eyes, suitability of donor material, procurement of the donor cornea, tissue assessment, storage and preservation, distribution of donor tissue, and limitation of eye bank will be discussed at the time of presentation

  3. SerpinE2, a poor biomarker of endometrial cancer, promotes the proliferation and mobility of EC cells.

    Science.gov (United States)

    Shen, Yuan; Wang, Xiaoyu; Xu, Jianping; Lu, Lin

    2017-07-04

    The SerpinE2 pathway is evolutionarily conserved and plays an important role in tumorigenesis. SerpinE2 (a small ubiquitin-related modifier), like ubiquitin, conjugates SerpinE2 proteins onto lysine residues of target proteins. SerpinE2 over-expression has been found in several tumors. Here, we detected the level of SerpinE2 in 72 samples of EC tissue using immunohistochemistry to assess the role of SerpinE2 in EC prognosis. Meanwhile, we knocked down SerpinE2 by siRNA in the HTB-111 and Ishikawa EC cell lines and analyzed the viability and mobility change using an MTT assay, an annexin V/PI apoptosis assay, a wound scratch test and a transwell assay. A Kaplan-Meier analysis indicated a negative correlation between the level of SerpinE2 and the EC prognosis. Silencing SerpinE2 induced cell apoptosis and reduced the migration ability. Our data suggest SerpinE2 works as an oncogene in EC.

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On ... Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms Causes of ...

  5. PRODUCTION OF BACTERIOCIN EC2 AND ITS INTERFERENCE IN THE GROWTH OF SALMONELLA TYPHI IN A MILK MATRIX

    Directory of Open Access Journals (Sweden)

    Yuri de Jesus Lopes de Abreu

    2013-08-01

    Full Text Available Bacterial interference can occur through various mechanisms, including the production of peroxides, acids, ammonia, bacteriolytic enzymes or bacteriocins. The strain Escherichia coli EC2 produces the antimicrobial substance (AMS EC2, able to inhibit different strains of Gram-negative bacteria isolated from food, as E. coli and Salmonella sp. The activity of AMS EC2 was lost after treatment with proteolytic enzymes, indicating the presence of an active proteinaceous compound, suggesting that it is a bacteriocin. The substance, renamed bacteriocin EC2, has its better production when the producer strain is grown on Casoy medium, at 37ºC and pH 6.0, without NaCl addition, but it is also able to be produced in milk. When co-cultivated in UHT milk with the producer strain E. coli EC2, the growth of the indicator strain Salmonella Typhi is totally inhibited within the first 4 hours of incubation, suggesting a potential application of bacteriocin EC2 in the control of Salmonella sp. e.g. in foods.

  6. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  7. Clinical comparison of technetium-99m-EC, technetium-99-m-MAG3 and Iodine-131-OIH in renal disorders

    International Nuclear Information System (INIS)

    Kabasakal, L.; Turoglu, T.; Oensel, C.

    1995-01-01

    Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of 99m Tc-EC were studied by constant infusion technique and compared with 99m Tc-MAG3 and 131 I-OIH in 11 patients with various renal disorders. After giving a 7.4 MBq 131 I-OIH and 90-110 MBq 99m Tc-EC or 99m Tc-MAG3 bolus, a constant infusion (MBq/ml) 99m Tc--agent and 0.07 MBq/m 131 I-OIH was started. Sixteen blood and five urine samples were obtained over three hr. The renal clearance of 99m Tc-EC was higher than than of 99m Tc-MAG3. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH ratios were 0.75 ± 0.05 and 0.55 ± 0.10 (p=0.00087), respectively. The distribution volume of 99m Tc-EC was also higher than that of 99m Tc-MAG3 (15722 ± 4644 and 9509 ± 2788 ml/1.73m 2 , respectively; p=0.072). The 99m Tc-EC/OIH and 99m Tc-MAG/OIH distribution volume ratios were 1.03 ± 0.14 and 0.55 ± 0.10, respectively (p = 0.0003). The 60-min excretion values of 99m Tc-EC and 99m Tc-MAG3 were compared to that of OIH. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH excretion ratios were 0.96 ± 0.06 and 1.07 ± 0.10, respectively (p=0.162). The protein binding of 99m -EC and OIH were found to be 34% ±4 and 66% ±5, respectively (p 99m Tc-EC was negligible (3% ±1.2) in comparison to OIH (27% ±3; p 99m Tc-EC. This agent has good potential for renal function evaluation. 32 refs., 5 tabs

  8. Vibrating makes for better seeing: from the fly's micro eye movements to hyperacute visual sensors

    Directory of Open Access Journals (Sweden)

    Stéphane eViollet

    2014-04-01

    Full Text Available Active vision means that visual perception not only depends closely on the subject's own movements, but that these movements actually contribute to the visual perceptual processes. Vertebrates' and invertebrates' eye movements are probably part of an active visual process, but their exact role still remains to be determined. In this paper, studies on the retinal micro-movements occurring in the compound eye of the fly are reviewed. Several authors have located and identified the muscles involved in these small retinal movements. Others have established that these retinal micro-movements occur in walking and flying flies, but their exact functional role still remains to be determined. Many robotic studies have been performed in which animals' (flies' and spiders' miniature eye movements have been modelled, simulated and even implemented mechanically. Several robotic platforms have been endowed with artificial visual sensors performing periodic micro-scanning movements. Artificial eyes performing these active retinal micro-movements have some extremely interesting properties, such as hyperacuity and the ability to detect very slow movements (motion hyperacuity. The fundamental role of miniature eye movements still remains to be described in detail, but several studies on natural and artificial eyes have advanced considerably toward this goal.

  9. Achievements and bottlenecks in humanitarian demining EU-funded research: final results from the EC DELVE project

    Science.gov (United States)

    Sahli, Hichem; Bruschini, Claudio; Van Kempen, Luc; Schleijpen, Ric; den Breejen, Eric

    2008-04-01

    The EC DELVE Support Action project has analyzed the bottlenecks in the transfer of Humanitarian Demining (HD) technology from technology development to the use in the field, and drawn some lessons learned, basing itself on the assessment of the European Humanitarian Demining Research and Technology Development (RTD) situation from early 1990 until 2006. The situation at the European level was analyzed with emphasis on activities sponsored by the European Commission (EC). This was also done for four European countries and Japan, with emphasis on national activities. The developments in HD during the last 10 years underline the fact that in a number of cases demining related developments have been terminated or at least put on hold. The study also showed that the funding provided by the EC under the Framework Program for RTD has led directly to the creation of an extensive portfolio of Humanitarian Demining technology development projects. The latter provided a range of research and supporting measures addressing the critical issues identified as a result of the regulatory policies developed in the field of Humanitarian Demining over the last ten years. However, the range of instruments available to the EC to finance the necessary research and development were limited, to pre-competitive research. The EC had no tools or programs to directly fund actual product development. As a first consequence, the EC funding program for development of technology for Humanitarian Demining unfortunately proved to be largely unsuitable for the small-scale development needed in a field where there is only a very limited market. As a second consequence, most of the research has been demonstrator-oriented. Moreover, the timeframe for RTD in Humanitarian Demining has not been sufficiently synchronized with the timeframe of the EC policies and regulations. The separation of the Mine Action and RTD funding streams in the EC did also negatively affect the take-up of new technologies. As a

  10. The biodistribution and radiation dosimetry of 99Tcmm-EC-DG in normal volunteers

    International Nuclear Information System (INIS)

    Tang Jun; Yang Yi; Liu Zengli; Shi Yizhen

    2010-01-01

    The objective of this study is to evaluate the biodistribution of technetium-99m labeled ethylenedicysteine-deoxyglucose ( 99 Tc m -EC-DG) and to calculate its internal radiation absorbed dose in normal volunteers. 740 MBq 99 Tc m -EC-DG was injected into the antecubital vein. 2 ml blood were sampled from the contralateral antecubital vein at different time after the injection, and its radioactivity was measured. The bi-exponential curve of time-radioactivity of blood and the dynamic parameters were obtained by using ORIGIN 5.0. Urine was collected in 24 hours after the injection and the percentage of Radioactivity excreted by urine to the total injected radioactivity was calculated. The anterior and posterior whole body imaging were acquired at different time after the injection of 740 MBq 99 Tc m -EC-DG. The region of interest of these referring organs and tissues was drawn, their radioactivity at different time was calculated. The bi-exponential curve of time-radioactivity of every organ was obtained by using ORIGIN 5.0, and then cumulated radioactivity and retaining time of 99 Tcm-EC-DG were calculated and input into the software MIRDOSE 3.0 to obtain the radiation absorbed dose of every organ and tissue. The heart rate, blood pressure and breathing frequency is normal after the injection. The male volunteer's T1/2α is 39 seconds, T1/2β is 59 minutes and that of female volunteer is 21 seconds and 61 minutes. 99 Tc m -EC-DG imaging is safe, and its characteristic of biodistribution in normal volunteer makes it easy to accumulate in tumor. Brain is not imaged, the uptake of muscle is low. The absorbed dose of every organ is far lower than that of the public annual average limitation. (authors)

  11. In the eye of the beholder: eye contact increases resistance to persuasion.

    Science.gov (United States)

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  12. Expression of a finger millet transcription factor, EcNAC1, in tobacco confers abiotic stress-tolerance.

    Directory of Open Access Journals (Sweden)

    Venkategowda Ramegowda

    Full Text Available NAC (NAM, ATAF1-2, and CUC2 proteins constitute one of the largest families of plant-specific transcription factors and have been shown to be involved in diverse plant processes including plant growth, development, and stress-tolerance. In this study, a stress-responsive NAC gene, EcNAC1, was isolated from the subtracted stress cDNA library generated from a drought adapted crop, finger millet, and characterized for its role in stress-tolerance. The expression analysis showed that EcNAC1 was highly induced during water-deficit and salt stress. EcNAC1 shares high amino acid similarity with rice genes that have been phylogenetically classified into stress-related NAC genes. Our results demonstrated that tobacco transgenic plants expressing EcNAC1 exhibit tolerance to various abiotic stresses like simulated osmotic stress, by polyethylene glycol (PEG and mannitol, and salinity stress. The transgenic plants also showed enhanced tolerance to methyl-viologen (MV induced oxidative stress. Reduced levels of reactive oxygen species (ROS and ROS-induced damage were noticed in pot grown transgenic lines under water-deficit and natural high light conditions. Root growth under stress and recovery growth after stress alleviation was more in transgenic plants. Many stress-responsive genes were found to be up-regulated in transgenic lines expressing EcNAC1. Our results suggest that EcNAC1 overexpression confers tolerance against abiotic stress in susceptible species, tobacco.

  13. Modulation of biosynthesis and regulatory action of 24(S),25-epoxycholesterol (S-EC) in cultured cells by progesterone (PG)

    International Nuclear Information System (INIS)

    Panini, S.R.; Gupta, A.K.; Sexton, R.C.; Parish, E.J.; Rudney, H.

    1987-01-01

    Treatment of IEC-6 cells with PG caused a strong inhibition of cholesterol biosynthesis at the level of desmosterol reductase. In addition, two new products were observed in PG-treated cells. The first compound was designated as cholesta-5,7,24-trien-3β-ol based on its HPLC chromatographic properties. The second compound was identified as S-EC based on (1) a comparison of its chromatographic properties with those of authentic EC and (2) by its conversion to 25-hydroxycholesterol (HC) upon reduction with LiAlH 4 . In spite of cellular accumulation of S-EC in the presence of PG, the activity of HMG-CoA reductase (HMGR) which is known to be sensitive to oxysterols, was elevated rather than suppressed. On the other hand, when PG-treated cells were refed fresh medium without PG, HMGR activity was suppressed. Exogenous S-EC was a potent suppressor of HMGR in untreated IEC-6 cells. Suppression of HMGR by S-EC but not by HC could be prevented by progesterone. Exogenous [ 3 H]S-EC was not metabolized by IEC-6 cells. These results support the hypothesis that S-EC plays a normal regulatory role in sterol biosynthesis and indicate that enhanced S-EC synthesis observed in the presence of PG may be due to interference with this regulatory action

  14. Estimation of the chemical-induced eye injury using a Weight-of-Evidence (WoE) battery of 21 artificial neural network (ANN) c-QSAR models (QSAR-21): part II: corrosion potential.

    Science.gov (United States)

    Verma, Rajeshwar P; Matthews, Edwin J

    2015-03-01

    This is part II of an in silico investigation of chemical-induced eye injury that was conducted at FDA's CFSAN. Serious eye damage caused by chemical (eye corrosion) is assessed using the rabbit Draize test, and this endpoint is an essential part of hazard identification and labeling of industrial and consumer products to ensure occupational and consumer safety. There is an urgent need to develop an alternative to the Draize test because EU's 7th amendment to the Cosmetic Directive (EC, 2003; 76/768/EEC) and recast Regulation now bans animal testing on all cosmetic product ingredients and EU's REACH Program limits animal testing for chemicals in commerce. Although in silico methods have been reported for eye irritation (reversible damage), QSARs specific for eye corrosion (irreversible damage) have not been published. This report describes the development of 21 ANN c-QSAR models (QSAR-21) for assessing eye corrosion potential of chemicals using a large and diverse CFSAN data set of 504 chemicals, ADMET Predictor's three sensitivity analyses and ANNE classification functionalities with 20% test set selection from seven different methods. QSAR-21 models were internally and externally validated and exhibited high predictive performance: average statistics for the training, verification, and external test sets of these models were 96/96/94% sensitivity and 91/91/90% specificity. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Inter-comparison of NIOSH and IMPROVE protocols for OC and EC determination: implications for inter-protocol data conversion

    Science.gov (United States)

    Wu, Cheng; Huang, X. H. Hilda; Ng, Wai Man; Griffith, Stephen M.; Zhen Yu, Jian

    2016-09-01

    Organic carbon (OC) and elemental carbon (EC) are operationally defined by analytical methods. As a result, OC and EC measurements are protocol dependent, leading to uncertainties in their quantification. In this study, more than 1300 Hong Kong samples were analyzed using both National Institute for Occupational Safety and Health (NIOSH) thermal optical transmittance (TOT) and Interagency Monitoring of Protected Visual Environment (IMPROVE) thermal optical reflectance (TOR) protocols to explore the cause of EC disagreement between the two protocols. EC discrepancy mainly (83 %) arises from a difference in peak inert mode temperature, which determines the allocation of OC4NSH, while the rest (17 %) is attributed to a difference in the optical method (transmittance vs. reflectance) applied for the charring correction. Evidence shows that the magnitude of the EC discrepancy is positively correlated with the intensity of the biomass burning signal, whereby biomass burning increases the fraction of OC4NSH and widens the disagreement in the inter-protocol EC determination. It is also found that the EC discrepancy is positively correlated with the abundance of metal oxide in the samples. Two approaches (M1 and M2) that translate NIOSH TOT OC and EC data into IMPROVE TOR OC and EC data are proposed. M1 uses direct relationship between ECNSH_TOT and ECIMP_TOR for reconstruction: M1 : ECIMP_TOR = a × ECNSH_TOT + b; while M2 deconstructs ECIMP_TOR into several terms based on analysis principles and applies regression only on the unknown terms: M2 : ECIMP_TOR = AECNSH + OC4NSH - (a × PCNSH_TOR + b), where AECNSH, apparent EC by the NIOSH protocol, is the carbon that evolves in the He-O2 analysis stage, OC4NSH is the carbon that evolves at the fourth temperature step of the pure helium analysis stage of NIOSH, and PCNSH_TOR is the pyrolyzed carbon as determined by the NIOSH protocol. The implementation of M1 to all urban site data (without considering seasonal specificity

  16. Improved Balance Confidence and Stability for Elderly After 6 Weeks of a Multimodal Self-Administered Balance-Enhancing Exercise Program

    Directory of Open Access Journals (Sweden)

    Anna Hafström MD, PhD

    2016-04-01

    Full Text Available Objective: To develop and assess the efficacy of a multimodal balance-enhancing exercise program (BEEP designed to be regularly self-administered by community-dwelling elderly. The program aims to promote sensory reweighting, facilitate motor control, improve gaze stabilization, and stimulate continuous improvement by being constantly challenging. Method: Forty participants aged 60 to 80 years performed 6 weeks of BEEP training, on average for 16 min four times weekly, in a randomized one-arm crossover design. Results: One-leg standing time improved 32% with eyes open (EO, 206% with eyes closed (EC on solid surface, and 54% EO on compliant surface ( p < .001. Posturography confirmed balance improvements when perturbed on solid and compliant surfaces with EO and EC ( p  ≤ .033. Walking, step stool, and Timed Up and Go speeds increased ( p  ≤ .001, as did scores in Berg Balance and balance confidence scales ( p  ≤ .018. Discussion: Multimodal balance exercises offer an efficient, cost-effective way to improve balance control and confidence in elderly.

  17. Postural control in restless legs syndrome with medication intervention using pramipexole.

    Science.gov (United States)

    Ahlgrén-Rimpiläinen, Aulikki; Lauerma, Hannu; Kähkönen, Seppo; Aalto, Heikki; Tuisku, Katinka; Holi, Matti; Pyykkö, Ilmari; Rimpiläinen, Ilpo

    2014-02-01

    Central dopamine regulation is involved in postural control and in the pathophysiology of restless legs syndrome (RLS) and Parkinson's disease (PD). Postural control abnormalities have been detected in PD, but there are no earlier studies with regard to RLS and postural control. Computerized force platform posturography was applied to measure the shift and the velocity (CPFV) of center point of forces (CPF) with eyes open (EO) and eyes closed (EC) in controls (n = 12) and prior and after a single day intervention with pramipexole in RLS subjects (n = 12). CPFV (EO) was significantly lower in the RLS group (p < 0.05) than in controls. After pramipexole intake, the difference disappeared and the subjective symptom severity diminished. Pramipexole did not significantly influence CPFV (EC) or CPF shift direction. Subjects with RLS used extensively visual mechanisms to control vestibule-spinal reflexes to improve or compensate the postural stability. Further research is needed to clarify altered feedback in the central nervous system and involvement of dopamine and vision in the postural control in RLS.

  18. EC tells Bonn let in UK coal

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-23

    The European Commission has told the German federal government to open the door for coal imports from other EC member countries. As an initial step, the Commission is suggesting that some of the power station coal which was to be sourced from German stockpiles under the November 1991 agreement between Rurhkohle AG, the state mining company and the generators, be supplied by other member states such as the UK. The implications of this move for the German coal industry are discussed. 2 tabs.

  19. Acupuncture for dry eye: a randomised controlled trial protocol

    Directory of Open Access Journals (Sweden)

    Kim Ae-Ran

    2009-12-01

    Full Text Available Abstract Background Dry eye is usually managed by conventional medical interventions such as artificial tears, anti-inflammatory drugs and surgical treatment. However, since dry eye is one of the most frequent ophthalmologic disorders, safer and more effective methods for its treatment are necessary, especially for vulnerable patients. Acupuncture has been widely used to treat patients with dry eye. Our aim is to evaluate the effectiveness and safety of acupuncture for this condition. Methods/Design A randomised, patient-assessor blinded, sham (non-acupuncture point, shallow acupuncture controlled study was established. Participants allocated to verum acupuncture and sham acupuncture groups will be treated three times weekly for three weeks for a total of nine sessions per participant. Seventeen points (GV23; bilateral BL2, GB4, TE23, Ex1 (Taiyang, ST1 and GB20; and left SP3, LU9, LU10 and HT8 for men, right for women have been selected for the verum acupuncture; for the sham acupuncture, points have been selected that do not coincide with a classical acupuncture point and that are located close to the verum points, except in the case of the rim of the eye. Ocular surface disease index, tear film breakup time, the Schirmer I test, medication quantification scale and general assessment of improvement will be used as outcome variables for evaluating the effectiveness of acupuncture. Safety will also be assessed at every visit. Primary and secondary outcomes will be assessed four weeks after screening. All statistical analyses will be performed using analysis of covariance. Discussion The results of this trial will be used as a basis for clarifying the efficacy of acupuncture for dry eye. Trial registration ClinicalTrials.gov NCT00969280.

  20. Creation of nano eye-drops and effective drug delivery to the interior of the eye

    Science.gov (United States)

    Ikuta, Yoshikazu; Aoyagi, Shigenobu; Tanaka, Yuji; Sato, Kota; Inada, Satoshi; Koseki, Yoshitaka; Onodera, Tsunenobu; Oikawa, Hidetoshi; Kasai, Hitoshi

    2017-03-01

    Nano eye-drops are a new type of ophthalmic treatment with increased potency and reduced side effects. Compounds in conventional eye-drops barely penetrate into the eye because the cornea, located at the surface of eye, has a strong barrier function for preventing invasion of hydrophilic or large-sized materials from the outside. In this work, we describe the utility of nano eye-drops utilising brinzolamide, a commercially available glaucoma treatment drug, as a target compound. Fabrication of the nanoparticles of brinzolamide prodrug increases the eye penetration rate and results in high drug efficacy, compared with that of commercially available brinzolamide eye-drops formulated as micro-sized structures. In addition, the resulting nano eye-drops were not toxic to the corneal epithelium after repeated administration for 1 week. The nano eye-drops may have applications as a next-generation ophthalmic treatment.

  1. Foam pad of appropriate thickness can improve diagnostic value of foam posturography in detecting postural instability.

    Science.gov (United States)

    Liu, Bo; Leng, Yangming; Zhou, Renhong; Liu, Jingjing; Liu, Dongdong; Liu, Jia; Zhang, Su-Lin; Kong, Wei-Jia

    2018-04-01

    The present study investigated the effect of foam thickness on postural stability in patients with unilateral vestibular hypofunction (UVH) during foam posturography. Static and foam posturography were performed in 33 patients (UVH group) and 30 healthy subjects (control group) with eyes open (EO) and closed (EC) on firm surface and on 1-5 foam pad(s). Sway velocity (SV) of center of pressure, standing time before falling (STBF) and falls reaction were recorded and analyzed. (1) SVs had an increasing tendency in both groups as the foam pads were added under EO and EC conditions. (2) STBFs, only in UVH group with EC, decreased with foam thickness increasing. (3) Significant differences in SV were found between the control and UVH group with EO (except for standing on firm surface, on 1 and 2 foam pad(s)) and with EC (all surface conditions). (4) Receiver operating characteristic curve analysis showed that the SV could better reflect the difference in postural stability between the two groups while standing on the 4 foam pads with EC. Our study showed that diagnostic value of foam posturography in detecting postural instability might be enhanced by using foam pad of right thickness.

  2. Lenses matching of compound eye for target positioning

    Science.gov (United States)

    Guo, Fang; Zheng, Yan Pei; Wang, Keyi

    2012-10-01

    Compound eye, as a new imaging method with multi-lens for a large field of view, could complete target positioning and detection fastly, especially at close range. Therefore it could be applicated in the fields of military and medical treatment and aviation with vast market potential and development prospect. Yet the compound eye imaging method designed use three layer construction of multiple lens array arranged in a curved surface and refractive lens and imaging sensor of CMOS. In order to simplify process structure and increase the imaging area of every sub-eye, the imaging area of every eye is coved with the whole CMOS. Therefore, for several imaging point of one target, the corresponding lens of every imaging point is unkonown, and thus to identify. So an algorithm was put forward. Firstly, according to the Regular Geometry relationship of several adjacent lenses, data organization of seven lenses with a main lens was built. Subsequently, by the data organization, when one target was caught by several unknown lenses, we search every combined type of the received lenses. And for every combined type, two lenses were selected to combine and were used to calculate one three-dimensional (3D) coordinate of the target. If the 3D coordinates are same to the some combine type of the lenses numbers, in theory, the lenses and the imaging points are matched. So according to error of the 3D coordinates is calculated by the different seven lenses numbers combines, the unknown lenses could be distinguished. The experimental results show that the presented algorithm is feasible and can complete matching task for imaging points and corresponding lenses.

  3. BullsEye

    DEFF Research Database (Denmark)

    Klokmose, Clemens Nylandsted; Kristensen, Janus Bager; Bagge, Rolf

    2014-01-01

    implemented primarily in shaders on the GPU. The techniques are realized in the BullsEye computer vision software. We demonstrate experimentally that BullsEye provides sub-pixel accuracy down to a tenth of a pixel, which is a significant improvement compared to the commonly used reacTIVision software....

  4. Registration of eye reflection and scene images using an aspherical eye model.

    Science.gov (United States)

    Nakazawa, Atsushi; Nitschke, Christian; Nishida, Toyoaki

    2016-11-01

    This paper introduces an image registration algorithm between an eye reflection and a scene image. Although there are currently a large number of image registration algorithms, this task remains difficult due to nonlinear distortions at the eye surface and large amounts of noise, such as iris texture, eyelids, eyelashes, and their shadows. To overcome this issue, we developed an image registration method combining an aspherical eye model that simulates nonlinear distortions considering eye geometry and a two-step iterative registration strategy that obtains dense correspondence of the feature points to achieve accurate image registrations for the entire image region. We obtained a database of eye reflection and scene images featuring four subjects in indoor and outdoor scenes and compared the registration performance with different asphericity conditions. Results showed that the proposed approach can perform accurate registration with an average accuracy of 1.05 deg by using the aspherical cornea model. This work is relevant for eye image analysis in general, enabling novel applications and scenarios.

  5. GPM GROUND VALIDATION ENVIRONMENT CANADA (EC) VAISALA CEILOMETER GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Environment Canada (EC) VAISALA Ceilometer GCPEx dataset was collected during the GPM Cold-season Precipitation Experiment (GCPEx) in...

  6. Technique charts for EC film: direct optical measurements to account for the effects of X-ray scatter

    International Nuclear Information System (INIS)

    Munro, Peter; Jordan, Kevin; Lewis, Craig; Heerema, Tim

    2001-01-01

    Purpose: To develop a method of measuring technique charts for enhanced contrast (EC) film, to demonstrate how X-ray scatter changes the response of EC film, and to generate technique charts for general use. Methods and Materials: We have developed a 'digital cassette' - consisting of a metal plate/phosphor screen, a light guide, a photodiode sensor, and an electrometer - that can be used to measure the light generated in the phosphor screen of the film cassette. In turn, these measurements can be used to generate technique charts for EC film. The digital cassette has been used to measure technique charts for 4-MV and 6-MV X-ray beams for a variety of different phantom thicknesses, field sizes, and phantom-to-cassette air gaps. Results and Discussion: We have observed that the signals generated in an ionization chamber located 9.4 cm behind a 30-cm-thick water-equivalent phantom increase by a factor of 1.9 when the field size is increased from 4x4 cm 2 to 40x40 cm 2 when irradiated by a 6-MV X-ray beam. However, the change in EC film response is a factor of 3.5 under the same conditions. Irradiations to optimally expose the EC film predicted by the digital cassette differ by up to 82% compared to those predicted by ion chamber measurements. Nevertheless, the technique charts measured using the digital cassette predict the response of the EC film to ±0.2 optical density. The overresponse of the EC film is most likely due to low-energy scattered photons, which interact with the high atomic number (Z=64) phosphor screen of the enhanced contrast localization cassette. Therefore, simple solutions, such as placing a high atomic number material above the enhanced contrast localization cassette, can reduce this contribution by scattered photons to the signal generated in the cassettes. Conclusions: We have developed a digital cassette that can make more accurate measurements of the technique charts for EC films. Our measurements show that under some conditions, X

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  8. Recognizing and Treating Eye Injuries

    Science.gov (United States)

    ... Eye Injuries First Aid for Eye Scratches Protective Eyewear Children’s Eye Injuries: Prevention and Care Eye Injuries ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  9. Comparison of novel lipid-based eye drops with aqueous eye drops for dry eye: a multicenter, randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Simmons PA

    2015-04-01

    Full Text Available Peter A Simmons, Cindy Carlisle-Wilcox, Joseph G Vehige Ophthalmology Research and Development, Allergan, Inc., Irvine, CA, USA Background: Dry eye may be caused or exacerbated by deficient lipid secretion. Recently, lipid-containing artificial tears have been developed to alleviate this deficiency. Our study compared the efficacy, safety, and acceptability of lipid-containing eye drops with that of aqueous eye drops.Methods: A non-inferiority, randomized, parallel-group, investigator-masked multicenter trial was conducted. Subjects with signs and symptoms of dry eye were randomized to use one of two lipid-containing artificial tears, or one of two aqueous artificial tears. Subjects instilled assigned drops in each eye at least twice daily for 30 days. The primary efficacy analysis tested non-inferiority of a preservative-free lipid tear formulation (LT UD to a preservative-free aqueous tear formulation (AqT UD for change in Ocular Surface Disease Index (OSDI score from baseline at day 30. Secondary measures included OSDI at day 7, tear break-up time (TBUT, corneal and conjunctival staining, Schirmer’s test, acceptability and usage questionnaires, and safety assessments.Results: A total of 315 subjects were randomized and included in the analyses. Subjects reported instilling a median of three doses of study eye drops per day in all groups. At days 7 and 30, all groups showed statistically significant improvements from baseline in OSDI (P<0.001 and TBUT (P≤0.005. LT UD was non-inferior to AqT UD for mean change from baseline in OSDI score at day 30. No consistent or clinically relevant differences for the other efficacy variables were observed. Acceptability was generally similar across the groups and there was a low incidence of adverse events.Conclusion: In this heterogeneous population of dry eye subjects, there were no clinically significant differences in safety, effectiveness, and acceptability between lipid-containing artificial tears

  10. Vitrectomy with internal limiting membrane peeling for macular hole in high myopia eyes

    Directory of Open Access Journals (Sweden)

    Chun-Mei Deng

    2015-08-01

    Full Text Available AIM: To compare the clinical effects between pars plana vitrectomy(PPVand PPV with internal limiting membrane peeling(ILMPfor macular hole in high myopia eyes. METHODS:The clinical data of 33 high myopia with macular hole patients(36 eyeswith or without retinal detachment caused by macular hole were retrospectively analyzed. The patients were divided into two groups according to different operation methods: 15 eyes in groupⅠhad undergone PPV; 21 eyes in groupⅡhad undergone PPV with ILMPP peeling. According to different conditions of patients,different auxiliary methods were accepted, such as silicone oil tamponade, C3F8 tamponade, photocoagulation, condensation, etc. The follow-up period was 3~12mo. Best corrected visual acuity(BCVA, macular hole closure rate and retinal reattachment rate were continuous checked after operation. Then we evaluated the outcome in the two groups by statistical analysis.RESULTS: The postoperative mean BCVA increased by 0.167 in group Ⅰand 0.456 in group Ⅱ than preoperative, the difference was significant(t=2.46,6.753; P=0.027,0.000. And the difference of BCVA improvement was significant between those two groups(t=-2.943, P=0.006. The macular hole closed in 7 eyes(46.67%in group Ⅰ,and 18 eyes(85.71%in group Ⅱ; The difference was significant between those two groups(χ2=6.287,P=0.025.Retinal reattachment was found in 11 eyes(91.67%in group Ⅰ and 19 eyes(94.73%in group Ⅱ. The difference was not significant between the two groups(χ2=0.856, P=0.418. CONCLUSION: PPV with ILMPP peeling for macular hole in high myopia eyes can obviously improve closure of macular hole and postoperative visual acuity. But the difference of retinal reattachment rate was not significant between peeling and unpeeling of ILMP.

  11. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    Science.gov (United States)

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  12. Uncertainty in CH4 and N2O emission estimates from a managed fen meadow using EC measurements

    International Nuclear Information System (INIS)

    Kroon, P.S.; Hensen, A.; Van 't Veen, W.H.; Vermeulen, A.T.; Jonker, H.

    2009-02-01

    The overall uncertainty in annual flux estimates derived from chamber measurements may be as high as 50% due to the temporal and spatial variability in the fluxes. As even a large number of chamber plots still cover typically less than 1% of the total field area, the field-scale integrated emission necessarily remains a matter of speculation. High frequency micrometeorological methods are a good option for obtaining integrated estimates on a hectare scale with a continuous coverage in time. Instrumentation is now becoming available that meets the requirements for CH4 and N2O eddy covariance (EC) measurements. A system consisting of a quantum cascade laser (QCL) spectrometer and a sonic anemometer has recently been proven to be suitable for performing EC measurements. This study analyses the EC flux measurements of CH4 and N2O and its corrections, like calibration, Webb-correction, and corrections for high and low frequency losses, and assesses the magnitude of the uncertainties associated with the precision of the measurement instruments, measurement set-up and the methodology. The uncertainty of one single EC flux measurement, a daily, monthly and 3-monthly average EC flux is estimated. In addition, the cumulative emission of C-CH4 and N-N2O and their uncertainties are determined over several fertilizing events at a dairy farm site in the Netherlands. These fertilizing events are selected from the continuously EC flux measurements from August 2006 to September 2008. The EC flux uncertainties are compared by the overall uncertainty in annual flux estimates derived from chamber measurements. It will be shown that EC flux measurements can decrease the overall uncertainty in annual flux estimates

  13. Uncertainty in CH4 and N2O emission estimates from a managed fen meadow using EC measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kroon, P.S.; Hensen, A.; Van ' t Veen, W.H.; Vermeulen, A.T. [ECN Biomass, Coal and Environment, Petten (Netherlands); Jonker, H. [Delft University of Technology, Delft (Netherlands)

    2009-02-15

    The overall uncertainty in annual flux estimates derived from chamber measurements may be as high as 50% due to the temporal and spatial variability in the fluxes. As even a large number of chamber plots still cover typically less than 1% of the total field area, the field-scale integrated emission necessarily remains a matter of speculation. High frequency micrometeorological methods are a good option for obtaining integrated estimates on a hectare scale with a continuous coverage in time. Instrumentation is now becoming available that meets the requirements for CH4 and N2O eddy covariance (EC) measurements. A system consisting of a quantum cascade laser (QCL) spectrometer and a sonic anemometer has recently been proven to be suitable for performing EC measurements. This study analyses the EC flux measurements of CH4 and N2O and its corrections, like calibration, Webb-correction, and corrections for high and low frequency losses, and assesses the magnitude of the uncertainties associated with the precision of the measurement instruments, measurement set-up and the methodology. The uncertainty of one single EC flux measurement, a daily, monthly and 3-monthly average EC flux is estimated. In addition, the cumulative emission of C-CH4 and N-N2O and their uncertainties are determined over several fertilizing events at a dairy farm site in the Netherlands. These fertilizing events are selected from the continuously EC flux measurements from August 2006 to September 2008. The EC flux uncertainties are compared by the overall uncertainty in annual flux estimates derived from chamber measurements. It will be shown that EC flux measurements can decrease the overall uncertainty in annual flux estimates.

  14. Epidemiological and occupational profile of eye trauma at a referral center in Espírito Santo, Brazil

    Directory of Open Access Journals (Sweden)

    Miquele Milanez

    Full Text Available ABSTRACT Objective: To draw an epidemiological and occupational profile of eye trauma at a Brazilian referral center, make comparisons with the literature and provide subsidies for the adoption of adequate prevention and enforcement measures. Methods: Descriptive and prospective epidemiological study using a standardized questionnaire to collect data from 60 patients presenting with eye trauma at an ophthalmology service (HUCAM between 1 april 2013 and 1 october 2013. Results: The male gender was predominant (80%. Ages ranged from 8 to 60 years. Most accidents (56.7% occurred in the workplace, followed by the home (28.3%. Most injuries were closed, predominantly contusions, followed by foreign body on the external eye. Importantly, 82.9% of the victims of work-related trauma wore no eye protection at the time of the accident. Conclusions: Eye trauma in the workplace and elsewhere is an important problem of public health as it affects primarily the economically active population and may have serious consequences. A considerable proportion of eye trauma is easily avoidable by using personal protective equipment. To minimize the incidence of eye trauma, more attention should be given to instruction in and enforcement of the use of such equipment, supported by frequent prevention campaigns.

  15. Immunology of the eye

    OpenAIRE

    Weronika Ratajczak; Beata Tokarz-Deptuła; Wiesław Deptuła

    2018-01-01

    The eye is an organ of sight characterized by unusual immunological properties, resulting from its anatomical structure and physiology, as well as the presence of specific elements that, through the mechanisms of innate and adaptive immunity, provide homeostasis of the eyeball. This article reviews the defensive elements of individual eye structures: conjunctiva, cornea, lacrimal gland, anterior chamber of the eye, uvea, retina and eye-associated lymphoid tissue (EALT), where we distinguish a...

  16. Choosing Wisely When It Comes to Eye Care: Punctal Plugs for Dry Eye

    Science.gov (United States)

    ... of Our 5-Part Series: Punctal Plugs for Dry Eye Making healthy lifestyle choices can help you protect ... discuss each item in detail. Punctal Plugs for Dry Eye Dry eye is a condition that millions of ...

  17. A Population-Based Assessment of the Agreement Between Grading of Goniophotographic Images and Gonioscopy in the Chinese-American Eye Study (CHES).

    Science.gov (United States)

    Murakami, Yohko; Wang, Dandan; Burkemper, Bruce; Lin, Shan C; Varma, Rohit

    2016-08-01

    To compare grading of goniophotographic images and gonioscopy in assessing the iridocorneal angle. In a population-based, cross-sectional study, participants underwent gonioscopy and goniophotographic imaging during the same visit. The iridocorneal angle was classified as closed if the posterior trabecular meshwork could not be seen. A single masked observer graded the goniophotographic images, and each eye was classified as having angle closure based on the number of closed quadrants. Agreement between the methods was analyzed by calculating kappa (κ) and first-order agreement coefficient (AC1) statistics and comparison of area under receiver operating characteristic curves (AUC). A total of 4149 Chinese Americans (3994 eyes) were included in this study. The agreement for angle closure diagnosis between gonioscopy and EyeCam was moderate to excellent (κ = 0.60, AC1 0.90, AUC 0.76-0.80). Detection of iridocorneal angle closure based on goniophotographic imaging shows moderate to very good agreement with angle closure assessment using gonioscopy.

  18. Eye Injuries at Work

    Science.gov (United States)

    ... National Standards Institute (ANSI) to meet their eye protection standards. If an eye injury occurs, see an ophthalmologist or go to the emergency room immediately, even if the eye injury appears minor. Delaying medical attention can result in permanent vision ...

  19. Transcriptome Analysis of the Planarian Eye Identifies ovo as a Specific Regulator of Eye Regeneration

    Directory of Open Access Journals (Sweden)

    Sylvain W. Lapan

    2012-08-01

    Full Text Available Among the millions of invertebrate species with visual systems, the genetic basis of eye development and function is well understood only in Drosophila melanogaster. We describe an eye transcriptome for the planarian Schmidtea mediterranea. Planarian photoreceptors expressed orthologs of genes required for phototransduction and microvillus structure in Drosophila and vertebrates, and optic pigment cells expressed solute transporters and melanin synthesis enzymes similar to those active in the vertebrate retinal pigment epithelium. Orthologs of several planarian eye genes, such as bestrophin-1 and Usher syndrome genes, cause eye defects in mammals when perturbed and were not previously described to have roles in invertebrate eyes. Five previously undescribed planarian eye transcription factors were required for normal eye formation during head regeneration. In particular, a conserved, transcription-factor-encoding ovo gene was expressed from the earliest stages of eye regeneration and was required for regeneration of all cell types of the eye.

  20. Transcriptome analysis of the planarian eye identifies ovo as a specific regulator of eye regeneration.

    Science.gov (United States)

    Lapan, Sylvain W; Reddien, Peter W

    2012-08-30

    Among the millions of invertebrate species with visual systems, the genetic basis of eye development and function is well understood only in Drosophila melanogaster. We describe an eye transcriptome for the planarian Schmidtea mediterranea. Planarian photoreceptors expressed orthologs of genes required for phototransduction and microvillus structure in Drosophila and vertebrates, and optic pigment cells expressed solute transporters and melanin synthesis enzymes similar to those active in the vertebrate retinal pigment epithelium. Orthologs of several planarian eye genes, such as bestrophin-1 and Usher syndrome genes, cause eye defects in mammals when perturbed and were not previously described to have roles in invertebrate eyes. Five previously undescribed planarian eye transcription factors were required for normal eye formation during head regeneration. In particular, a conserved, transcription-factor-encoding ovo gene was expressed from the earliest stages of eye regeneration and was required for regeneration of all cell types of the eye. Copyright © 2012 The Authors. Published by Elsevier Inc. All rights reserved.

  1. A laser-based eye-tracking system.

    Science.gov (United States)

    Irie, Kenji; Wilson, Bruce A; Jones, Richard D; Bones, Philip J; Anderson, Tim J

    2002-11-01

    This paper reports on the development of a new eye-tracking system for noninvasive recording of eye movements. The eye tracker uses a flying-spot laser to selectively image landmarks on the eye and, subsequently, measure horizontal, vertical, and torsional eye movements. Considerable work was required to overcome the adverse effects of specular reflection of the flying-spot from the surface of the eye onto the sensing elements of the eye tracker. These effects have been largely overcome, and the eye-tracker has been used to document eye movement abnormalities, such as abnormal torsional pulsion of saccades, in the clinical setting.

  2. Extracted facial feature of racial closely related faces

    Science.gov (United States)

    Liewchavalit, Chalothorn; Akiba, Masakazu; Kanno, Tsuneo; Nagao, Tomoharu

    2010-02-01

    Human faces contain a lot of demographic information such as identity, gender, age, race and emotion. Human being can perceive these pieces of information and use it as an important clue in social interaction with other people. Race perception is considered the most delicacy and sensitive parts of face perception. There are many research concerning image-base race recognition, but most of them are focus on major race group such as Caucasoid, Negroid and Mongoloid. This paper focuses on how people classify race of the racial closely related group. As a sample of racial closely related group, we choose Japanese and Thai face to represents difference between Northern and Southern Mongoloid. Three psychological experiment was performed to study the strategies of face perception on race classification. As a result of psychological experiment, it can be suggested that race perception is an ability that can be learn. Eyes and eyebrows are the most attention point and eyes is a significant factor in race perception. The Principal Component Analysis (PCA) was performed to extract facial features of sample race group. Extracted race features of texture and shape were used to synthesize faces. As the result, it can be suggested that racial feature is rely on detailed texture rather than shape feature. This research is a indispensable important fundamental research on the race perception which are essential in the establishment of human-like race recognition system.

  3. Signalling properties of identified deep cerebellar nuclear neurons related to eye and head movements in the alert cat.

    Science.gov (United States)

    Gruart, A; Delgado-García, J M

    1994-07-01

    1. The spike activity of deep cerebellar nuclear neurons was recorded in the alert cat during spontaneous and during vestibularly and visually induced eye movements. 2. Neurons were classified according to their location in the nuclei, their antidromic activation from projection sites, their sensitivity to eye position and velocity during spontaneous eye movements, and their responses to vestibular and optokinetic stimuli. 3. Type I EPV (eye position and velocity) neurons were located mainly in the posterior part of the fastigial nucleus and activated antidromically almost exclusively from the medial longitudinal fasciculus close to the oculomotor complex. These neurons, reported here for the first time, increased their firing rate during saccades and eye fixations towards the contralateral hemifield. Their position sensitivity to eye fixations in the horizontal plane was 5.3 +/- 2.6 spikes s-1 deg-1 (mean +/- S.D.). Eye velocity sensitivity during horizontal saccades was 0.71 +/- 0.52 spikes s-1 deg-1 s-1. Variability of their firing rate during a given eye fixation was higher than that shown by abducens motoneurons. 4. Type I EPV neurons increased their firing rate during ipsilateral head rotations at 0.5 Hz with a mean phase lead over eye position of 95.3 +/- 9.5 deg. They were also activated by contralateral optokinetic stimulation at 30 deg s-1. Their sensitivity to eye position and velocity in the horizontal plane during vestibular and optokinetic stimuli yielded values similar to those obtained for spontaneous eye movements. 5. Type II neurons were located in both fastigial and dentate nuclei and were activated antidromically from the restiform body, the medial longitudinal fasciculus close to the oculomotor complex, the red nucleus and the pontine nuclei. Type II neurons were not related to spontaneous eye movements. These neurons increased their firing rate in response to contralateral head rotation and during ipsilateral optokinetic stimulation, and

  4. Setting up a child eye care centre: the Mercy Eye Hospital, Abak ...

    African Journals Online (AJOL)

    Aim: To document and share our experience in setting up a Child Eye Care Centre within a rural mission eye hospital and document subsequent development of services. Method: The location of the project was Mercy Eye Hospital (MEH) Abak, Akwa Ibom State in the South South zone of Nigeria). Consent to commence ...

  5. The role of the IGF-1 Ec in myoskeletal system and osteosarcoma pathophysiology.

    Science.gov (United States)

    Armakolas, Nikolaos; Armakolas, Athanasios; Antonopoulos, Athanasios; Dimakakos, Andreas; Stathaki, Martha; Koutsilieris, Michael

    2016-12-01

    Growth hormone (GH) regulated mainly liver-produced insulin-like growth factor 1 (IGF-1) is a key molecule in embryonic & post embryonic development that is also involved in cancer biology. Herein we review new insights of the role of igf-1 gene products and of the IGF-1Ec isoform in muscle and bone development/repair and its role in osteosarcoma pathophysiology, underlying the possible role of the Ec peptide as a future therapeutic target. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. socio-ec(h)o: Ambient Intelligence and Gameplay

    OpenAIRE

    Wakkary, Ron

    2005-01-01

    The socio-ec(h)o project aims to research a generalized ambient intelligent software platform and design models for responsive environments based on the concept of ambient intelligent "ecologies" and group gameplay. The benefits of the research include a software-architecture, ambient intelligence inference engine, and interaction design models for gameplay and responsive environments. The paper will discuss the results of our prototypes for games in responsive environments. These prototypes ...

  7. Trustworthy-looking face meets brown eyes.

    Directory of Open Access Journals (Sweden)

    Karel Kleisner

    Full Text Available We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the effect for female faces not being significant. To determine whether perception of trustworthiness was being influenced primarily by eye color or by face shape, we recolored the eyes on the same male facial photos and repeated the test procedure. Eye color now had no effect on perceived trustworthiness. We concluded that although the brown-eyed faces were perceived as more trustworthy than the blue-eyed ones, it was not brown eye color per se that caused the stronger perception of trustworthiness but rather the facial features associated with brown eyes.

  8. Characteristics of eye-position gain field populations determine geometry of visual space

    Directory of Open Access Journals (Sweden)

    Sidney R Lehky

    2016-01-01

    Full Text Available We have previously demonstrated differences in eye-position spatial maps for anterior inferotemporal cortex (AIT in the ventral stream and lateral intraparietal cortex (LIP in the dorsal stream, based on population decoding of gaze angle modulations of neural visual responses (i.e., eye-position gain fields. Here we explore the basis of such spatial encoding differences through modeling of gain field characteristics. We created a population of model neurons, each having a different eye-position gain field. This population was used to reconstruct eye-position visual space using multidimensional scaling. As gain field shapes have never been well established experimentally, we examined different functions, including planar, sigmoidal, elliptical, hyperbolic, and mixtures of those functions. All functions successfully recovered positions, indicating weak constraints on allowable gain field shapes. We then used a genetic algorithm to modify the characteristics of model gain field populations until the recovered spatial maps closely matched those derived from monkey neurophysiological data in AIT and LIP. The primary differences found between model AIT and LIP gain fields were that AIT gain fields were more foveally dominated. That is, gain fields in AIT operated on smaller spatial scales and smaller dispersions than in LIP. Thus we show that the geometry of eye-position visual space depends on the population characteristics of gain fields, and that differences in gain field characteristics for different cortical areas may underlie differences in the representation of space.

  9. [Characteristics and sources apportionment of OC and EC in PM1.1 from Nanjing].

    Science.gov (United States)

    Jiang, Wen-juan; Guo, Zhao-bing; Liu, Feng-ling; Rui, Mao-ling; Shi, Lei; Zeng, Gang; Guo, Zi-yan

    2015-03-01

    The concentrations of OC and EC in PM1.1 collected from Nanshi (NS) and Nanhua (NH) in 2011 were analyzed using DRI Model 2001A Thermal Optical Carbon Analyzer. In addition, source apportionment was simultaneously evaluated. The results showed that the annual average concentrations of OC and EC in PM1.1 were 10. 10 μg x m(-3) and 2.52 μg x m(-3) in NS area, and 11.22 μg x m(-3) and 3.12 μg x m(-3) in NH area, respectively. This result indicated that OC and EC pollution in NH was more serious than that in NS area. Meanwhile, the concentrations of OC and EC in winter and spring were obviously higher compared to those in summer in these two sampling sites, which was mainly ascribed to the increased coal combustion and the unfavorable emission condition of air pollutants in summer and spring. We noted that the SOC/TOC value was the highest in summer and the lowest in winter. In addition, the SOC concentration was observed to show a positive correlation with ozone concentrations, which indicated that the photochemical reaction was a main way of SOC formation in autumn.

  10. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  11. Acute and repeated ECS treatment increases CRF, POMC and PENK gene expression in selected regions of the rat hypothalamus.

    Science.gov (United States)

    Garcia-Garcia, L; Llewellyn-Jones, V; Fernandez Fernandez, I; Fuentes, J A; Manzanares, J

    1998-01-05

    The purpose of this study was to investigate the effects of acute and repeated electroconvulsive shock (ECS) on corticotropin releasing factor (CRF), proopiomelanocortin (POMC) and proenkephalin (PENK) gene expression in selected regions of the brain and pituitary of the rat. Acute ECS increased CRF gene expression in the paraventricular nucleus (PVN) by 20%, an effect that was further enhanced to 38% when rats received repeated ECS treatment. Acute and repeated ECS increased POMC gene expression in the arcuate nucleus (ARC) by 49-59% but failed to alter these mRNA levels in the anterior lobe (AL) of the pituitary gland. PENK gene expression was increased by 35% in the nucleus accumbens (NA) and by 180% the ventromedial nucleus (VMN) after acute or repeated ECS treatment but no significant changes were found in the PVN or striatum (ST). Taken together, these results indicate a differential CRF and opioid gene expression regulation after acute or repeated ECS treatment that may be relevant to their therapeutic or side effects in depression.

  12. Advocacy for eye care

    Directory of Open Access Journals (Sweden)

    Thulasiraj D Ravilla

    2012-01-01

    Full Text Available The effectiveness of eye care service delivery is often dependant on how the different stakeholders are aligned. These stakeholders range from the ministries of health who have the capacity to grant government subsidies for eye care, down to the primary healthcare workers who can be enrolled to screen for basic eye diseases. Advocacy is a tool that can help service providers draw the attention of key stakeholders to a particular area of concern. By enlisting the support, endorsement and participation of a wider circle of players, advocacy can help to improve the penetration and effectiveness of the services provided. There are several factors in the external environmental that influence the eye care services - such as the availability of trained manpower, supply of eye care consumables, government rules and regulations. There are several instances where successful advocacy has helped to create an enabling environment for eye care service delivery. Providing eye care services in developing countries requires the support - either for direct patient care or for support services such as producing trained manpower or for research and dissemination. Such support, in the form of financial or other resources, can be garnered through advocacy.

  13. Daily changes of structure, function and rhodopsin content in the compound eye of the crab Hemigrapsus sanguineus.

    Science.gov (United States)

    Arikawa, K; Kawamata, K; Suzuki, T; Eguchi, E

    1987-08-01

    The compound eye of the crab hemigrapsus sanguineus undergoes daily changes in morphology as determined by light and electron microscopy, both in the quantity of chromophore substances studied by HPLC and in visual sensitivity as shown by electrophysiological techniques. 1. At a temperature of 20 degrees C, the rhabdom occupation ratio (ROR) of an ommatidial retinula was 11.6% (maximum) at midnight, 8.0 times larger than the minimum value at midday (1.4%). 2. Observations by freeze-fracture revealed that the densities of intra-membranous particles (9-11 nm in diameter) of rhabdomeric membrane were ca. 2000/microns 2 and ca. 3000/microns 2 for night and daytime compound eyes, respectively. 3. Screening pigment granules migrated longitudinally and aggregated at night, but dispersed during the day. Reflecting pigment granules migrate transversally in the proximal half of the reticula layer i.e. cytoplasmic extensions containing reflecting pigment granules squeeze between neighbouring retinula cells causing optical isolation (Fig. 4). Thus the screening pigment granules within the retinula cells show longitudinal migration and radial movement so that the daytime rhabdoms are closely surrounded by the pigment granules. 4. At 20 degrees C, the total amount of chromophore of the visual pigment (11-cis and all-trans-retinal) was 1.4 times larger at night than during the day i.e. 46.6 pmol/eye at midnight and 33.2 pmol/eye at midday. Calculations of the total surface area of rhabdomeric membrane, total number of intra-membranous particles in rhabdomeric membrane and the total number of chromophore molecules in a compound eye, indicate that a considerable amount of chromophore-protein complex exists outside the rhabdom during the day. 5. The change in rhabdom size and quantity of chromophore were highly dependent on temperature. At 10 degrees C both rhabdom size and amount of chromophore stayed close to daytime levels throughout the 24 hours. 6. The intracellularly

  14. Prevention of Eye Injuries

    OpenAIRE

    Pashby, Tom

    1981-01-01

    In Canada 30,000 people are registered as blind; in one third of these, blindness might have been avoided. Prevention is the key to reducing the number of eye injuries and blind eyes. The role of the family physician in early identification of treatable conditions and in the education of patients is discussed, but responsibility for prevention belongs to all physicians. The success of prevention is seen in the great reduction in eye injuries in industry and sports since eye protectors have be...

  15. About the Eye

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  16. Penetrating eye injury in war.

    Science.gov (United States)

    Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L

    1999-11-01

    The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons.

  17. Warm-Core Intensification Through Horizontal Eddy Heat Transports into the Eye

    Science.gov (United States)

    Braun, Scott A.; Montgomery, Michael T.; Fulton, John; Nolan, David S.; Starr, David OC. (Technical Monitor)

    2001-01-01

    The mechanism for the formation and intensification of the hurricane warm core is not well understood. The generally accepted explanation is that the warm core forms as a result of gentle subsidence of air within the eye that warms as a result of adiabatic compression. Malkus suggested that this subsidence is part of a deep circulation in which air begins descent at high levels in the eye, acquires cyclonic angular momentum as it descends to lower levels, and then diverges at low levels, where it is entrained back into the eyewall. Inward mixing from the eyewall is hypothesized to force the subsidence and maintain the moisture and momentum budgets of the subsiding air. Willoughby suggested that air within the eye has remained so since it was first enclosed during the formation of the eyewall and that it subsides at most only a few kilometers rather than through the depth of the troposphere. He relates the subsidence to the low-level divergence and entrainment into the eyewall noted by Malkus, but suggests that shrinkage of the eye's volume is more than adequate to account for the air lost to the eyewall or converted to cloudy air by turbulent mixing across the eye boundary. Smith offered an alternative view of the subsidence forcing, suggesting that vertical motion in a mature hurricane eye is generated largely by imbalances between the downward vertical pressure gradient force and the upward buoyancy force. The vertical pressure gradient force is associated with the decay and/or radial spread of the tangential wind field with height at those levels were the winds are in approximate gradient wind balance. The rate of subsidence is just that required to warm the air sufficiently such that the buoyancy remains in close hydrostatic balance with an increasing vertical pressure gradient force. In this study, a very high-resolution simulation of Hurricane Bob using a cloud-resolving grid scale of 1.3 km is used to examine the heat budget within the storm with particular

  18. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy Beth; Ellervik, Christina; Buch, Helena

    2016-01-01

    , Danish Rural Eye Study (DRES). All DRES participants received a comprehensive general health examination preceding their eye examination, including measurement of best-corrected visual acuity (BCVA) for each eye, bilateral 45° retinal fundus photographs and further ophthalmological examination where...... indicated. RESULTS: Overall, 3826 of 3843 participants (99.6%) had bilateral visual acuity measurements. The overall frequency of VI (BCVA eye) was 0.4% (95% confidence interval, CI, 0.2-0.7%; n = 15) among all DRES participants, 0.6% (95% CI 0.3-1.0%; n = 15) among participants...... >50 years and 3.7% (95% CI 2.1-6.5%; n = 11) in participants >80 years. The primary causes of VI in the better-seeing eye were age-related macular degeneration (AMD) in 46.7% (7/15) and cataract in 26.7% (4/15). A total of 43.3% (n = 115) of participants >80 years were pseudophakic in one or both eyes...

  19. Clinical observation of Qiming granule combined with Dextran and Hypromellose eye drops for dry eye

    Directory of Open Access Journals (Sweden)

    Jin-Lan Wan

    2013-09-01

    Full Text Available AIM: To observe the efficacy of Qiming granule combined with Dextran and Hypromellose eye drops in treatment of dry eye.METHODS: A randomized, parallel-control approach was adopted, 100 cases of dry eye patients were divided into treatment group and control group equally, observation on the treatment of 3 months. The treatment group was applied Dextran and Hypromellose eye drops combined with oral Qiming granule, simply Dextran and Hypromellose eye drops for control group. Before and after treatment, tear secretion volume, break-up time, corneal fluorescein staining and symptom were observed.RESULTS: After treatment, there was statistical significance for the break-up time, SⅠt and corneal fluorescein staining in both groups when compared with before treatment(PPCONCLUSION: The combined Dextran and Hypromellose eye drops and Qiming granule perform better than Dextran and Hypromellose eye drops only in treatment of dry eye.

  20. Preventing Eye Injuries

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  1. Cancer cells cause vascular endothelial cell (vEC) retraction via 12(S)HETE secretion; the possible role of cancer cell derived microparticle.

    Science.gov (United States)

    Uchide, Keiji; Sakon, Masato; Ariyoshi, Hideo; Nakamori, Syouji; Tokunaga, Masaru; Monden, Morito

    2007-02-01

    Cancer cell mediated vascular endothelial cell (vEC) retraction plays a pivotal role in cancer metastasis. The aim of this study is to clarify the biochemical character of vEC retraction factor derived from human breast cancer cell line, MCF-7. In order to estimate vEC retracting activity, transwell chamber assay system was employed. We first tested the effects of trypsin digestion as well as lipid extraction of culture medium (CM). Trypsin digestion of CM resulted in approximately 40% loss of vEC retracting activity and lipid extraction of CM by Brigh and Dyer methods recovered approximately 60% of vEC retracting activity, suggesting that approximately 60% of vEC retracting activity in MCF-7 derived CM is due to lipid. Although Nordihydroguaiaretic acid (NDGA), the specific lipoxygenase inhibitor, suppressed vEC retracting activity in CM, Acetyl salicylic acid (ASA), a specific cyclooxygenase inhibitor, did not affect the activity, suggesting that lipid exerting vEC retracting activity in CM belongs to lipoxygenase mediated arachidonate metabolites. Thin layer chromatography clearly demonstrated that Rf value of lipid vEC retracting factor in CM is identical to 12HETE. Authentic 12(S)HETE, but not 12(R)HETE, showed vEC retracting activity. After the ultracentrifugation of CM, most lipid vEC retracting activity was recovered from the pellet fraction, and flow cytometric analysis using specific antibody against 12(S)HETE clearly showed the association of 12(S)HETE with small particle in CM. These findings suggested the principal involvement of 12(S)HETE in cancer cell derived microparticles in cancer cell mediated vEC retraction.

  2. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  3. Impact of First Eye versus Second Eye Cataract Surgery on Visual Function and Quality of Life.

    Science.gov (United States)

    Shekhawat, Nakul S; Stock, Michael V; Baze, Elizabeth F; Daly, Mary K; Vollman, David E; Lawrence, Mary G; Chomsky, Amy S

    2017-10-01

    To compare the impact of first eye versus second eye cataract surgery on visual function and quality of life. Cohort study. A total of 328 patients undergoing separate first eye and second eye phacoemulsification cataract surgeries at 5 veterans affairs centers in the United States. Patients with previous ocular surgery, postoperative endophthalmitis, postoperative retinal detachment, reoperation within 30 days, dementia, anxiety disorder, hearing difficulty, or history of drug abuse were excluded. Patients received complete preoperative and postoperative ophthalmic examinations for first eye and second eye cataract surgeries. Best-corrected visual acuity (BCVA) was measured 30 to 90 days preoperatively and postoperatively. Patients completed the National Eye Institute Visual Functioning Questionnaire (NEI-VFQ) 30 to 90 days preoperatively and postoperatively. The NEI-VFQ scores were calculated using a traditional subscale scoring algorithm and a Rasch-refined approach producing visual function and socioemotional subscale scores. Postoperative NEI-VFQ scores and improvement in NEI-VFQ scores comparing first eye versus second eye cataract surgery. Mean age was 70.4 years (±9.6 standard deviation [SD]). Compared with second eyes, first eyes had worse mean preoperative BCVA (0.55 vs. 0.36 logarithm of the minimum angle of resolution (logMAR), P < 0.001), greater mean BCVA improvement after surgery (-0.50 vs. -0.32 logMAR, P < 0.001), and slightly worse postoperative BCVA (0.06 vs. 0.03 logMAR, P = 0.039). Compared with first eye surgery, second eye surgery resulted in higher postoperative NEI-VFQ scores for nearly all traditional subscales (P < 0.001), visual function subscale (-3.85 vs. -2.91 logits, P < 0.001), and socioemotional subscale (-2.63 vs. -2.10 logits, P < 0.001). First eye surgery improved visual function scores more than second eye surgery (-2.99 vs. -2.67 logits, P = 0.021), but both first and second eye surgeries resulted in similar

  4. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.

  5. Reading paths, eye drawings, and word islands: Movement in Un coup de dés.

    Science.gov (United States)

    Loos, Ruth

    2012-01-01

    In the framework of an artistic-scientific project on eye-movements during reading, my collaborators from the psychology department at the KU Leuven and I had a close look at the poem "Un coup de dés jamais n'abolira le hasard" ("A throw of the dice will never abolish chance") by Stéphane Mallarmé. The poem is an intriguing example of nonlinear writing, of a typographic game with white and space, and of an interweaving of different reading lines. These specific features evoke multiple reading methods. The animation, Movement in Un coup de dés, created during the still-ongoing collaboration interweaves a horizontal and a vertical reading method, two spontaneous ways of reading that point at the poem's intriguing ambiguity. Not only are we interested in different methods of reading; the scientific representations of eye movements themselves are a rich source of images with much artistic potential. We explore eye movements as "eye drawings" in new images characterized both by a scientific and by an artistic perspective.

  6. Reading Paths, Eye Drawings, and Word Islands: Movement in Un coup de dés

    Directory of Open Access Journals (Sweden)

    Ruth Loos

    2012-01-01

    Full Text Available In the framework of an artistic–scientific project on eye-movements during reading, my collaborators from the psychology department at the KU Leuven and I had a close look at the poem “Un coup de dés jamais n'abolira le hasard” (“A throw of the dice will never abolish chance” by Stéphane Mallarmé. The poem is an intriguing example of nonlinear writing, of a typographic game with white and space, and of an interweaving of different reading lines. These specific features evoke multiple reading methods. The animation, Movement in Un coup de dés, created during the still-ongoing collaboration interweaves a horizontal and a vertical reading method, two spontaneous ways of reading that point at the poem's intriguing ambiguity. Not only are we interested in different methods of reading; the scientific representations of eye movements themselves are a rich source of images with much artistic potential. We explore eye movements as “eye drawings” in new images characterized both by a scientific and by an artistic perspective.

  7. Real-Time Control of a Video Game Using Eye Movements and Two Temporal EEG Sensors.

    Science.gov (United States)

    Belkacem, Abdelkader Nasreddine; Saetia, Supat; Zintus-art, Kalanyu; Shin, Duk; Kambara, Hiroyuki; Yoshimura, Natsue; Berrached, Nasreddine; Koike, Yasuharu

    2015-01-01

    EEG-controlled gaming applications range widely from strictly medical to completely nonmedical applications. Games can provide not only entertainment but also strong motivation for practicing, thereby achieving better control with rehabilitation system. In this paper we present real-time control of video game with eye movements for asynchronous and noninvasive communication system using two temporal EEG sensors. We used wavelets to detect the instance of eye movement and time-series characteristics to distinguish between six classes of eye movement. A control interface was developed to test the proposed algorithm in real-time experiments with opened and closed eyes. Using visual feedback, a mean classification accuracy of 77.3% was obtained for control with six commands. And a mean classification accuracy of 80.2% was obtained using auditory feedback for control with five commands. The algorithm was then applied for controlling direction and speed of character movement in two-dimensional video game. Results showed that the proposed algorithm had an efficient response speed and timing with a bit rate of 30 bits/min, demonstrating its efficacy and robustness in real-time control.

  8. In the Eye of the Beholder-  A Survey of Models for Eyes and Gaze

    DEFF Research Database (Denmark)

    Witzner Hansen, Dan; Ji, Qiang

    2010-01-01

    Despite active research and significant progress in the last 30 years, eye detection and tracking remains challenging due to the individuality of eyes, occlusion, variability in scale, location, and light conditions. Data on eye location and details of eye movements have numerous applications and...

  9. 哈氏弧菌EcGY020401优化培养%Optimization Culture of Vibrio harveyi EcGY020401

    Institute of Scientific and Technical Information of China (English)

    陶家发; 赖迎迢; 潘厚军; 石存斌; 吴淑勤

    2010-01-01

    目的:为规模化制备弧菌疫苗提供相关数据.方法:利用摇瓶和小型发酵罐培养,通过平板计数测定培养菌液的活菌数.结果:哈氏弧菌(Vibrio harveyi)EcGY020401株最适盐度为20~25g/L,合适的pH为7.5~7.7,葡萄糖浓度最适浓度为2~5g/L,用TSB优化培养基:胰蛋白胨5g/L、蛋白胨15g/L、大豆蛋白胨3g/L、酵母膏1g/L、葡萄糖4g/L、磷酸氢二钾5g/L、氯化钠15g/L、pH 7.5,培养EcGY020401菌株,可达2.95×1010 cfu/mL;小型发酵罐培养,10h可达到生长最大值,菌液浓度为3.46×1010cfu/mL 结论:用优化TSB培养基,采用发酵罐培养弧菌,可降低成本,提搞培养效率.

  10. Function and Evolutionary Origin of Unicellular Camera-Type Eye Structure

    KAUST Repository

    Hayakawa, Shiho

    2015-03-03

    The ocelloid is an extraordinary eyespot organelle found only in the dinoflagellate family Warnowiaceae. It contains retina- and lens-like structures called the retinal body and the hyalosome. The ocelloid has been an evolutionary enigma because of its remarkable resemblance to the multicellular camera-type eye. To determine if the ocelloid is functionally photoreceptive, we investigated the warnowiid dinoflagellate Erythropsidinium. Here, we show that the morphology of the retinal body changed depending on different illumination conditions and the hyalosome manifests the refractile nature. Identifying a rhodopsin gene fragment in Erythropsidinium ESTs that is expressed in the retinal body by in situ hybridization, we also show that ocelloids are actually light sensitive photoreceptors. The rhodopsin gene identified is most closely related to bacterial rhodopsins. Taken together, we suggest that the ocelloid is an intracellular camera-type eye, which might be originated from endosymbiotic origin. © 2015 Hayakawa et al.

  11. Function and Evolutionary Origin of Unicellular Camera-Type Eye Structure

    KAUST Repository

    Hayakawa, Shiho; Takaku, Yasuharu; Hwang, Jung Shan; Horiguchi, Takeo; Suga, Hiroshi; Gehring, Walter; Ikeo, Kazuho; Gojobori, Takashi

    2015-01-01

    The ocelloid is an extraordinary eyespot organelle found only in the dinoflagellate family Warnowiaceae. It contains retina- and lens-like structures called the retinal body and the hyalosome. The ocelloid has been an evolutionary enigma because of its remarkable resemblance to the multicellular camera-type eye. To determine if the ocelloid is functionally photoreceptive, we investigated the warnowiid dinoflagellate Erythropsidinium. Here, we show that the morphology of the retinal body changed depending on different illumination conditions and the hyalosome manifests the refractile nature. Identifying a rhodopsin gene fragment in Erythropsidinium ESTs that is expressed in the retinal body by in situ hybridization, we also show that ocelloids are actually light sensitive photoreceptors. The rhodopsin gene identified is most closely related to bacterial rhodopsins. Taken together, we suggest that the ocelloid is an intracellular camera-type eye, which might be originated from endosymbiotic origin. © 2015 Hayakawa et al.

  12. NASA's "Eyes" Focus on Education

    Science.gov (United States)

    Hussey, K.

    2016-12-01

    NASA's "Eyes on…" suite of products continues to grow in capability and popularity. The "Eyes on the Earth", "Eyes on the Solar System" and "Eyes on Exoplanets" real-time, 3D interactive visualization products have proven themselves as highly effective demonstration and communication tools for NASA's Earth and Space Science missions. This presentation will give a quick look at the latest updates to the "Eyes" suite plus what is being done to make them tools for STEM Education.

  13. Consumption of food in EC countries

    International Nuclear Information System (INIS)

    Ven-Breken, T.J. van de; Brenot, J.; Bonnefous, S.; Noordijk, H.; Leenhouts, H.P.

    1990-08-01

    Annual consumption of 10 classes of food and drink is reported for the total population of each EC-country. National food consumption data are generalized by distinguishing groups of countries with similar diet. Group 1: UK and Ireland (low consumption of fruit, high consumption of potatoes and fresh dairy products). Group 2: Italy and Greece (high consumption of cereals, vegetables and fruit, low consumption of fresh dairy products). Group 3: France, Belgium, Luxembourg, Netherlands, FRG and Spain (intermediate consumption of most foodstuffs). Portugal and Denmark could not be classified in any group. Changes in food consumption related to differences in age, sex, social class, regional habits and level of urbanisation are reported.In some cases, variation of annual food consumption over the different seasons on the relative contribution of food from local origin to the total diet, could be estimated. Differences of region, age and level of urbanisation appear to have the largest influence on consumed amounts. As for age, the values for the different age-groups range from 50 to 80 percent of the adult diet. Regional consumption may diverge from 70-130 percent of the average national consumption, with values of 200 percent for potatoes and fruit. Consumption in urban areas compared with the entire country diverges from 70-100 percent. In rural areas the values diverge from 100-140 percent. Self-support of vegetables and milk seems to be important for most countries. Of the other products, self-support of wheat and cheese is only of importance in the south of the EC. When combining the effects of the different factors, a range of consumed amounts for specific population groups of 50 to 200 percent of the average national consumption was determined. (author). 38 refs.; 13 figs.; 75 tabs

  14. Summary of ANSYS and Strain Gauge Results for the EC Calorimeter OH and MH Modules

    International Nuclear Information System (INIS)

    Wands, R.; Weber, K.; Zurawski, J.

    1987-01-01

    The OH and MH modules of the EC calorimeter consist essentially of metal boxes containing calorimetry plates. These plates can contribute to the module behavior only in compression, with this effect being enhanced if the plates are compressively preloaded against the skin of the box prior to assembly. The finite element method can be applied in the analysis of these modules. Its advantages are: 1. The structural components can be modeled with less simplification than beam theory allows. The angled faces of the OH modules can be represented exactly, and the shear deflections inherent in short, deep beams will be a natural part of the solution. 2. The finite element method can be subjected to any number of realistic loadings. 3. With proper mesh density relevant stresses can be extracted. The disadvantages of the method are that exact modeling of the internal plates is difficult, time consuming, and computationally expensive. It is of interest, then, to verify how well a simple model of the structural components only (i.e., the skin, endplates, and any structural internal plates) predicts deflections and stresses which can be relied on for design purposes. The finite element modeling of the OH and MH EC modules has been under constant review since the technique was first applied to these structures. Early verification attempts were based on comparison of finite element deflection predictions with measured module deflections. These comparisons were not entirely successful, due primarily, in the author's opinion, to the difficulty of measuring the actual module deflections with acceptable accuracy. It was proposed in October, 1986, that verification be based on stress, rather than deflection. The purpose of this report is to summarize the results of four experiments which were conducted to determine the accuracy with which ANSYS finite element models could predict the stresses in the OH and MH EC modules as measured by strain gauges. The three comparisons with actual

  15. annot8r: GO, EC and KEGG annotation of EST datasets

    Directory of Open Access Journals (Sweden)

    Schmid Ralf

    2008-04-01

    Full Text Available Abstract Background The expressed sequence tag (EST methodology is an attractive option for the generation of sequence data for species for which no completely sequenced genome is available. The annotation and comparative analysis of such datasets poses a formidable challenge for research groups that do not have the bioinformatics infrastructure of major genome sequencing centres. Therefore, there is a need for user-friendly tools to facilitate the annotation of non-model species EST datasets with well-defined ontologies that enable meaningful cross-species comparisons. To address this, we have developed annot8r, a platform for the rapid annotation of EST datasets with GO-terms, EC-numbers and KEGG-pathways. Results annot8r automatically downloads all files relevant for the annotation process and generates a reference database that stores UniProt entries, their associated Gene Ontology (GO, Enzyme Commission (EC and Kyoto Encyclopaedia of Genes and Genomes (KEGG annotation and additional relevant data. For each of GO, EC and KEGG, annot8r extracts a specific sequence subset from the UniProt dataset based on the information stored in the reference database. These three subsets are then formatted for BLAST searches. The user provides the protein or nucleotide sequences to be annotated and annot8r runs BLAST searches against these three subsets. The BLAST results are parsed and the corresponding annotations retrieved from the reference database. The annotations are saved both as flat files and also in a relational postgreSQL results database to facilitate more advanced searches within the results. annot8r is integrated with the PartiGene suite of EST analysis tools. Conclusion annot8r is a tool that assigns GO, EC and KEGG annotations for data sets resulting from EST sequencing projects both rapidly and efficiently. The benefits of an underlying relational database, flexibility and the ease of use of the program make it ideally suited for non

  16. Interim report of the JHPS expert committee on radiation protection of the lens of the eye (5). Current occupational radiation exposure of the lens of the eye in Japan

    International Nuclear Information System (INIS)

    Akahane, Keiichi; Tatsuzaki, Hideo; Iimoto, Takeshi; Ichiji, Takeshi; Hamada, Nobuyuki; Fujimichi, Yuki; Iwai, Satoshi; Ohguchi, Hiroyuki; Ohno, Kazuko; Yamauchi-Kawaura, Chiyo; Tsujimura, Norio; Hotta, Yutaka; Yamasaki, Tadashi; Yokoyama, Sumi

    2015-01-01

    For many Japanese radiation workers in the medical, nuclear and other industrial fields, the equivalent dose of the lens of the eye will be sufficiently lower than the new ICRP dose limit. However, the dose of the eye for medical staff members who are engaged in interventional radiology and cardiology may exceed the new ICRP dose limit, especially when they are exposed closely to higher scatter radiation for a long time. In addition, the radiation dosimetry and radiation protection for emergency and recovery workers in the Fukushima Daiichi Nuclear Power Plant (FNPP1) are important issues. Thus gathering information related to the radiation dose and protection for Japanese radiation workers is important to a discussion regarding implementation of the new ICRP dose limit for the lens of the eye for Japanese regulations and planning radiation dose reduction measures. In this paper, recent studies and issues regarding radiation exposure and protection in the medical, nuclear and other industrial fields, as well as for emergency and recovery workers in the FNPP1 were summarized. (author)

  17. Eye Pull, Eye Push: Moving Objects between Large Screens and Personal Devices with Gaze and Touch

    OpenAIRE

    Turner , Jayson; Alexander , Jason; Bulling , Andreas; Schmidt , Dominik; Gellersen , Hans

    2013-01-01

    Part 4: Gaze-Enabled Interaction Design; International audience; Previous work has validated the eyes and mobile input as a viable approach for pointing at, and selecting out of reach objects. This work presents Eye Pull, Eye Push, a novel interaction concept for content transfer between public and personal devices using gaze and touch. We present three techniques that enable this interaction: Eye Cut & Paste, Eye Drag & Drop, and Eye Summon & Cast. We outline and discuss several scenarios in...

  18. Post-destructive eye surgery, associated depression at Sekuru Kaguvi Hospital Eye Unit, Zimbabwe: Pilot Study

    Directory of Open Access Journals (Sweden)

    M. M. Kawome

    2013-12-01

    Full Text Available Destructive eye surgery is associated with more complications than just loss of visual functions of the eye and aesthetics. Currently there is very little published literature on post-destructive eye surgery associated depression. Zimbabwe has been experiencing a surge in the rate of destructive eye surgery done at the National Tertiary Eye Unit. This situation could be churning out lots of unrecognized depressed clients into the community who require assistance in one form or another. Objectives: To determine the prevalence of post-destructive eye surgery associated depression among patients attending Sekuru Kaguvi Hospital Eye Unit and assess if the current management protocol of patients undergoing destructive eye surgery at the Eye Unit addresses the problem adequately. Methods: A cross-sectional study of 28 randomly selected patients who had destructive eye surgeries at Sekuru Kaguvi Hospital was conducted over five months from 1st March 2012 to end of July 2012. A structured questionnaire containing 15 questions on the following items: gender, age, diagnosis, surgical procedure done, expectations before and after surgery, adequacy of counseling given and involvement of family was used to collect data. Nine questions to assess depression were adapted from the Patient Health Questionnaire (PHQ-9. Setting:  The study was conducted at SekuruKaguvi Hospital Eye Unit, Parirenyatwa Group of Hospitals in Harare. Results:  Twenty-eight patients who underwent destructive eye surgery during the study period were selected using systematic random sampling. The gender ratio was 1:1 and the mean age was 38.7 years with a range from 24 to 65 years. Fifty percent of the patients in the study had orbital exenteration while the rest had enucleation (14% and evisceration (36%. Twenty-eight percent of the study population had depression. Conclusion: Destructive eye surgery is frequently associated with depression and our current management protocol of

  19. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid ... Your eyes are made up of many different parts that work together to help you see. Check out the ...

  20. A new verification film system for routine quality control of radiation fields: Kodak EC-L.

    Science.gov (United States)

    Hermann, A; Bratengeier, K; Priske, A; Flentje, M

    2000-06-01

    The use of modern irradiation techniques requires better verification films for determining set-up deviations and patient movements during the course of radiation treatment. This is an investigation of the image quality and time requirement of a new verification film system compared to a conventional portal film system. For conventional verifications we used Agfa Curix HT 1000 films which were compared to the new Kodak EC-L film system. 344 Agfa Curix HT 1000 and 381 Kodak EC-L portal films of different tumor sites (prostate, rectum, head and neck) were visually judged on a light box by 2 experienced physicians. Subjective judgement of image quality, masking of films and time requirement were checked. In this investigation 68% of 175 Kodak EC-L ap/pa-films were judged "good", only 18% were classified "moderate" or "poor" 14%, but only 22% of 173 conventional ap/pa verification films (Agfa Curix HT 1000) were judged to be "good". The image quality, detail perception and time required for film inspection of the new Kodak EC-L film system was significantly improved when compared with standard portal films. They could be read more accurately and the detection of set-up deviation was facilitated.

  1. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Jing Chen

    2017-10-01

    Full Text Available AIM: To compare and analyze the effect of recombinant bovine basic fibroblast growth factor(bFGFeye drops and hydroxyl indican eye drops on the tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: A total of 115 patients(115 affected eyeswith dry eyes after age-related cataract surgery were divided into the bFGF group, the hydroxyl indican group and the blank control group by the random number table method. The blank control group was only given routine anti-inflammatory treatment, and on the basis, the bFGF group and the hydroxyl indican group were treated with bFGF eye drops and hydroxyl indican eye drops respectively. The clinical efficacy, adverse reactions, changes in scores of dry eye symptoms, Schirmer test(SⅠt, tear film break-up time(BUTand corneal fluorescein staining(CFSscores at different time points were compared among the three groups. RESULTS: The total markedly effective rates in the bFGF group(89.5%was higher than that in the hydroxyl indican group(70.3%or the blank control group(47.5%(PPPCONCLUSION: The tear film is unstable in early stage after age-related cataract surgery, and there are dry eye symptoms. The intervention with bFGF eye drops and hydroxyl indican eye drops can effectively restore the tear film stability and significantly relieve dry eye symptoms, and the effect of bFGF eye drops is more significant.

  2. Eye Disease and Development

    DEFF Research Database (Denmark)

    Andersen, Thomas Barnebeck; Dalgaard, Carl-Johan Lars; Selaya, Pablo

    This research advances the hypothesis that cross-country variation in the historical incidence of eye disease has influenced the current global distribution of per capita income. The theory is that pervasive eye disease diminished the incentive to accumulate skills, thereby delaying the fertility...... transition and the take-off to sustained economic growth. In order to estimate the influence from eye disease incidence empirically, we draw on an important fact from the field of epidemiology: Exposure to solar ultraviolet B radiation (UVB-R) is an underlying determinant of several forms of eye disease...

  3. Post-LASIK dry eye

    Science.gov (United States)

    Shtein, Roni M

    2011-01-01

    Laser-assisted in situ keratomileusis (LASIK) is a frequently performed corneal refractive surgery with excellent refractive outcomes. The most common complication of LASIK is dry eyes, with virtually all patients developing some degree of dryness in the immediate postoperative period. Identifying preoperative dry eyes, and conscientious attention and treatment in the perioperative time period, can lead to enhanced patient satisfaction and more accurate visual outcomes. Improved understanding of the development of dry eyes after LASIK will advance our understanding of the complex pathophysiology of dry eye disease. PMID:22174730

  4. Clinical observation of Qiming granule combined with Dextran and Hypromellose eye drops for dry eye

    OpenAIRE

    Jin-Lan Wan; Ming-Chang Zhang

    2013-01-01

    AIM: To observe the efficacy of Qiming granule combined with Dextran and Hypromellose eye drops in treatment of dry eye.METHODS: A randomized, parallel-control approach was adopted, 100 cases of dry eye patients were divided into treatment group and control group equally, observation on the treatment of 3 months. The treatment group was applied Dextran and Hypromellose eye drops combined with oral Qiming granule, simply Dextran and Hypromellose eye drops for control group. Before and after tr...

  5. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  6. Contrast and assimilation in motion perception and smooth pursuit eye movements.

    Science.gov (United States)

    Spering, Miriam; Gegenfurtner, Karl R

    2007-09-01

    The analysis of visual motion serves many different functions ranging from object motion perception to the control of self-motion. The perception of visual motion and the oculomotor tracking of a moving object are known to be closely related and are assumed to be controlled by shared brain areas. We compared perceived velocity and the velocity of smooth pursuit eye movements in human observers in a paradigm that required the segmentation of target object motion from context motion. In each trial, a pursuit target and a visual context were independently perturbed simultaneously to briefly increase or decrease in speed. Observers had to accurately track the target and estimate target speed during the perturbation interval. Here we show that the same motion signals are processed in fundamentally different ways for perception and steady-state smooth pursuit eye movements. For the computation of perceived velocity, motion of the context was subtracted from target motion (motion contrast), whereas pursuit velocity was determined by the motion average (motion assimilation). We conclude that the human motion system uses these computations to optimally accomplish different functions: image segmentation for object motion perception and velocity estimation for the control of smooth pursuit eye movements.

  7. Ankylosing Spondylitis and Posture Control: The Role of Visual Input

    Science.gov (United States)

    De Nunzio, Alessandro Marco; Iervolino, Salvatore; Zincarelli, Carmela; Di Gioia, Luisa; Rengo, Giuseppe; Multari, Vincenzo; Peluso, Rosario; Di Minno, Matteo Nicola Dario; Pappone, Nicola

    2015-01-01

    Objectives. To assess the motor control during quiet stance in patients with established ankylosing spondylitis (AS) and to evaluate the effect of visual input on the maintenance of a quiet posture. Methods. 12 male AS patients (mean age 50.1 ± 13.2 years) and 12 matched healthy subjects performed 2 sessions of 3 trials in quiet stance, with eyes open (EO) and with eyes closed (EC) on a baropodometric platform. The oscillation of the centre of feet pressure (CoP) was acquired. Indices of stability and balance control were assessed by the sway path (SP) of the CoP, the frequency bandwidth (FB1) that includes the 80% of the area under the amplitude spectrum, the mean amplitude of the peaks (MP) of the sway density curve (SDC), and the mean distance (MD) between 2 peaks of the SDC. Results. In severe AS patients, the MD between two peaks of the SDC and the SP of the center of feet pressure were significantly higher than controls during both EO and EC conditions. The MP was significantly reduced just on EC. Conclusions. Ankylosing spondylitis exerts negative effect on postural stability, not compensable by visual inputs. Our findings may be useful in the rehabilitative management of the increased risk of falling in AS. PMID:25821831

  8. Ankylosing Spondylitis and Posture Control: The Role of Visual Input

    Directory of Open Access Journals (Sweden)

    Alessandro Marco De Nunzio

    2015-01-01

    Full Text Available Objectives. To assess the motor control during quiet stance in patients with established ankylosing spondylitis (AS and to evaluate the effect of visual input on the maintenance of a quiet posture. Methods. 12 male AS patients (mean age 50.1 ± 13.2 years and 12 matched healthy subjects performed 2 sessions of 3 trials in quiet stance, with eyes open (EO and with eyes closed (EC on a baropodometric platform. The oscillation of the centre of feet pressure (CoP was acquired. Indices of stability and balance control were assessed by the sway path (SP of the CoP, the frequency bandwidth (FB1 that includes the 80% of the area under the amplitude spectrum, the mean amplitude of the peaks (MP of the sway density curve (SDC, and the mean distance (MD between 2 peaks of the SDC. Results. In severe AS patients, the MD between two peaks of the SDC and the SP of the center of feet pressure were significantly higher than controls during both EO and EC conditions. The MP was significantly reduced just on EC. Conclusions. Ankylosing spondylitis exerts negative effect on postural stability, not compensable by visual inputs. Our findings may be useful in the rehabilitative management of the increased risk of falling in AS.

  9. Studies with the EC-Earth seamless Earth system prediction model

    NARCIS (Netherlands)

    Hazeleger, W.; Bintanja, R.

    2012-01-01

    EC-Earth is a new Earth System Model (ESM) based on the operational seasonal forecast system of the European Centre for Medium-Range Weather Forecasts (ECMWF). Climate and weather forecasting applications share a common ancestry and are build on the same physical principles. The emerging concept of

  10. Impurity analysis in EC-99mTC radiotracer using chromatographic techniques

    International Nuclear Information System (INIS)

    Almeida, E.V.; Fukumori, N.T.O.; Mengatti, J.; Silva, C.P.G.; Matsuda, M.M.N.

    2008-01-01

    The objective of this study was to develop two chromatographic methods of impurity analysis in radiotracer 99m Tc-EC: the Thin Layer Chromatography (TLC) and the High Performance Liquid Chromatography Reversed Phase (HPLC-RP)

  11. Static Balance of Visually Impaired Athletes in Open and Closed Skill Sports

    Directory of Open Access Journals (Sweden)

    Bednarczuk Grzegorz

    2017-03-01

    Full Text Available Introduction. In elite sport, athletes are required to maintain appropriate body posture control despite a number of destabilising factors. The functions of body posture control are monitored by the central nervous system that constantly receives information from the vestibular and somatosensory systems as well as from the visual analyser. Visual impairment may contribute to a decrease in the level of motor abilities and skills; however, it does not prevent visually impaired individuals from taking up physical activity. Therefore, this study sought to assess the static balance of visually impaired goalball players and shooters. Material and methods. The study included 37 goalball players and 20 shooters. A force platform was used to assess static balance. The study participants performed tests: standing on both feet with eyes open (BFEO and closed (BFEC (30 s, single left- and right-leg stance with eyes open (SLEO and SREO as well as single left- and right-leg stance with eyes closed (SLEC and SREC. Statistical analyses were carried out using the following parameters: centre of pressure (CoP path length [cm], CoP velocity [m/s], and the surface area of the stabilogram [cm2]. Results. No significant differences were found between goalball players and shooters in static balance levels. However, such differences were observed after taking into account the number of athletes who were capable of performing particular tests. Conclusions. The findings indirectly confirm that there is a correlation between the type of physical activity and balance levels in visually impaired individuals. Further research ought to include tests performed on an unstable surface.

  12. About the Eye

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  13. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... much as it does on your eyes. ... of Health | USA.gov NIH…Turning Discovery Into Health ®

  14. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI for Kids >> About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  15. About the Eye

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes ...

  16. About the Eye

    Medline Plus

    Full Text Available ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about ...

  17. Serum antibodies and DNA indicate a high prevalence of equine papillomavirus 2 (EcPV2) among horses in Switzerland.

    Science.gov (United States)

    Fischer, Nina M; Favrot, Claude; Birkmann, Katharina; Jackson, Michele; Schwarzwald, Colin C; Müller, Martin; Tobler, Kurt; Geisseler, Marco; Lange, Christian E

    2014-06-01

    The DNA of equine papillomavirus type 2 (EcPV2) is consistently found in equine papillomas and squamous cell carcinomas, indicating a causal association of EcPV2 in the pathogenesis of these tumours; however, little is known about the prevalence of this virus. The aim of this study was to determine the geno- and seroprevalence of EcPV2 in clinically healthy horses in Switzerland. Fifty horses presented to the equine department of the university clinic, displaying no skin or mucous membrane lesions or severe signs of other diseases, were sampled. Cytobrush samples from the penis or vulva and serum samples were collected. To determine the genoprevalence of EcPV2, DNA was extracted from cytobrush samples and tested for viral DNA with a PCR assay amplifying a 338 bp fragment of the E7/E1 region of the viral genome. Seroprevalence was tested using an enzyme-linked immunosorbent assay aimed to detect antibodies against the major capsid protein (L1) of EcPV2. In five of 50 horses (10%), EcPV2-specific DNA was amplified but no antibodies could be detected, whereas in 14 of 50 horses (28%), antibodies against EcPV2 but no DNA were demonstrated. Both antibodies and viral DNA were detected in four of 50 horses (8%). Neither antibodies nor viral DNA were found in 27 of 50 horses (54%). The seroprevalence suggests that EcPV2 is prevalent in the Swiss equine population, while the genoprevalence indicates that currently ongoing infections are less common. The discrepancy between geno- and seroprevalence probably indicates different stages of infection in the tested cohort. © 2014 ESVD and ACVD.

  18. Individual Differences in Spatial Knowledge Acquisition from a Virtual Environment: An Eye-Tracking Study

    Directory of Open Access Journals (Sweden)

    Ryosuke Uenaka

    2011-05-01

    Full Text Available Previous studies have shown that spatial knowledge acquisition differs across individuals in both real and virtual environments. For example, in a real environment, Ishikawa & Montello (2006 showed that some participants had almost perfect configural knowledge of the environment after one or two learning trials, whereas others performed at chance even after repeated learning trials. Using a virtual version of Ishikawa & Montello's layouts, we measured eye movements while participants were learning a layout of a route, as eye movements are shown to be closely linked to performance in spatial navigation tasks. We prepared three different layouts of a route depicted in a desktop virtual environment, along with the locations of four landmarks on that route. After learning each of the routes, we administered three different measures of spatial knowledge: numbering the landmark order, estimation of direction, and map sketching. Self-reported sense-of-direction (SDQ-S was also measured. Behavioral analyses showed positive correlations across the routes in the estimation of direction. However, consistent correlations were not observed between eye movements and performance of the estimation of direction in each route. Those results suggest that eye movements do not predict individual differences in spatial knowledge acquisition.

  19. simEye: computer-based simulation of visual perception under various eye defects using Zernike polynomials

    OpenAIRE

    Fink, Wolfgang; Micol, Daniel

    2006-01-01

    We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set of Zernike polynomials that are fitted to input data for the respective surfaces. A ray-tracing procedure propagates light rays using Snell’s law of refraction from an input objec...

  20. [Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].

    Science.gov (United States)

    Amm, M; Hedderich, J

    2005-01-01

    The Goldmann applanation technique established itself as gold standard for clinical intraocular pressure (IOP) measurement. But the device measures by corneal touch and presupposes corneal conditions within a normal range. So precise determination of IOP is crucial in corneal disorders and after corneal surgery. This pilot study presents tonometry data of normal and postkeratoplasty eyes measured transpalpebrally with a digital tonometer in comparison to Goldmann tonometry. The TGDc-01 tonometer is based on a ballistic principle of measurement. IOP was measured in 50 healthy eyes (group 1) and 40 eyes after penetrating keratoplasty (group 2) first by the TGDc-01 and after 3 minutes by Goldmann tonometry (Haag-Streit). Subjective refraction, keratometry and ultrasonic pachymetry were performed in all eyes. The IOP measurements in the postkeratoplasty eyes were done when corneal epithelium was fully closed and only a medium suture edema could be observed. The Pearson's product-moment correlation was r=0,46 for group 1 and 0,65 for group 2. Using the concordance correlation coefficient the value showed a reproducibility index of r(c)=0,44 in group 1 and r(c)=0,60 in group 2. Following the Bland-Altman-analysis 58% of the cases in group 1 had a difference between the two instruments of maximum 3 mmHg. In group 2, 53,5% of the eyes showed an absolute difference between Goldmann and TDGc-01 of 3 mmHg or less. A transpalpebral measurement technique-avoiding corneal contact-seems to be an alternative choice in patients with corneal pathologies and after corneal surgery. The TGDc-01 tonometer provided mostly similar results compared to the Goldmann device, but with fluctuations. Keeping the deviations between the two methods in mind we recommend, however, the use of the transpalpebral approach only in combination with other techniques (palpation, indentation) to obtain enough reliability of IOP information in problem eyes.

  1. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  2. About the Eye

    Medline Plus

    Full Text Available ... Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  3. About the Eye

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  4. Pink Eye (Conjunctivitis)

    Science.gov (United States)

    ... or child care if you're not able to take time off — just stay consistent in practicing good hygiene. Preventing pink eye in newborns Newborns' eyes are susceptible to bacteria normally present in the mother's birth canal. ...

  5. About the Eye

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ...

  6. Humor in the eye tracker: attention capture and distraction from context cues.

    Science.gov (United States)

    Strick, Madelijn; Holland, Rob W; Van Baaren, Rick; Van Knippenberg, Ad

    2010-01-01

    The humor effect refers to a robust finding in memory research that humorous information is easily recalled, at the expense of recall of nonhumorous information that was encoded in close temporal proximity. Previous research suggests that memory retrieval processes underlie this effect. That is, free recall is biased toward humorous information, which interferes with the retrieval of nonhumorous information. The present research tested an additional explanation that has not been specifically addressed before: Humor receives enhanced attention during information encoding, which decreases attention for context information. Participants observed humorous, nonhumorous positive, and nonhumorous neutral texts paired with novel consumer brands, while their eye movements were recorded using eye-tracker technology. The results confirmed that humor receives prolonged attention relative to both positive and neutral nonhumorous information. This enhanced attention correlated with impaired brand recognition.

  7. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists

  8. About the Eye

    Medline Plus

    Full Text Available ... Home » NEI for Kids » About the Eye Listen All About Vision About the Eye Ask a Scientist ... you can see and make sense of the world around you. Did You Know? Vision depends on ...

  9. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI for Kids » About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  10. A 16-Channel Nonparametric Spike Detection ASIC Based on EC-PC Decomposition.

    Science.gov (United States)

    Wu, Tong; Xu, Jian; Lian, Yong; Khalili, Azam; Rastegarnia, Amir; Guan, Cuntai; Yang, Zhi

    2016-02-01

    In extracellular neural recording experiments, detecting neural spikes is an important step for reliable information decoding. A successful implementation in integrated circuits can achieve substantial data volume reduction, potentially enabling a wireless operation and closed-loop system. In this paper, we report a 16-channel neural spike detection chip based on a customized spike detection method named as exponential component-polynomial component (EC-PC) algorithm. This algorithm features a reliable prediction of spikes by applying a probability threshold. The chip takes raw data as input and outputs three data streams simultaneously: field potentials, band-pass filtered neural data, and spiking probability maps. The algorithm parameters are on-chip configured automatically based on input data, which avoids manual parameter tuning. The chip has been tested with both in vivo experiments for functional verification and bench-top experiments for quantitative performance assessment. The system has a total power consumption of 1.36 mW and occupies an area of 6.71 mm (2) for 16 channels. When tested on synthesized datasets with spikes and noise segments extracted from in vivo preparations and scaled according to required precisions, the chip outperforms other detectors. A credit card sized prototype board is developed to provide power and data management through a USB port.

  11. GPM GROUND VALIDATION ENVIRONMENT CANADA (EC) MANUAL PRECIPITATION MEASUREMENTS GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Environment Canada (EC) Manual Precipitation Measurements GCPEx dataset was collected during the GPM Cold-season Precipitation Experiment...

  12. Inflammation in dry eye.

    Science.gov (United States)

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  13. ECONOMIC AND LEGAL ASPECTS OF THE PLANNED DAMAGES ACTIONS FOR THE BREACHES OF EC ANTITRUST LAW

    Directory of Open Access Journals (Sweden)

    Elena Isac

    2010-09-01

    Full Text Available This paper investigates the planned damages actions for breaches of EC antitrust law in order to assess their impact on consumer welfare. It first examines the current legal situation and concurs that the European Union needs to regulate damages actions for breaches of EC antitrust law so that a higher number of consumers could be compensated for their losses. This paper then discusses the main legal provisions proposed by the Commission in the Green and in the White paper on damages actions for breaches of EC antitrust law. The analysis of these proposed legal provisions is done using arguments specific to the economic analysis of law. It is demonstrated that most of these proposed legal provisions will enhance consumer welfare but that there are also proposed legal provisions which will damage consumer welfare. The paper concludes that the planned damages actions for breaches of the EC law will be an improvement compared to the current situation. However, the Commission should amend some of the proposed legal provisions in order to help consumers further.

  14. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and ...

  15. Q and A. Why the EC's PINC has failed Europe's nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Kraev, Kamen [NucNet, Brussels (Belgium)

    2016-12-15

    The European Economic and Social Committee (EESC) has called for a more comprehensive strategy to be incorporated in a revised version of the European Commission's (EC) Illustrative Programme for Nuclear Energy (PINC). EESC member Brian Curtis tells NucNet why the PINC has failed to address key issues for nuclear and why he believes the EC has become side-tracked by renewables. The EESC is a consultative body which represents the interests of civil society organisations and stakeholders at the EU. Its opinions are forwarded to the EC, the European Council, and the European Parliament and are considered in the EU's decision-making process. Brian Curtis was rapporteur on the committee's opinion paper.

  16. 'An eye, for eyes - mission' - From dream to reality

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2013-10-01

    Full Text Available Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global shortage of donor corneas [2]. At this juncture Yokoo et al isolated and expanded corneal endothelial precursors using the sphere forming assay in vitro [3] and demonstrated the in vivo transplantation of these corneal endothelial precursors in a rabbit model of bullous keratopathy [4]. Following this, we studied the transportation of cadaver donor derived corneal endothelial tissue (CET from human cadaver donors in a thermoreversible gelation polymer (TGP (4 based transportation cocktail without cool preservation and demonstrated the viability of human corneal endothelial precursor (HCEP cells isolated from these CETs even after 72 hours of transportation without cool preservation [5]. This was done to suit the conditions existing in developing nations like India where hospitals might be located far from eye banks and maintaining cold chain preservation is relatively difficult. Further, these HCEPs were expanded in vitro using a polymer based expansion protocol [5]. This was the first step in the realisation of the dream of 'Eye for eyes' in a manner suitable for Indian conditions. Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global

  17. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    Science.gov (United States)

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  18. Towards Coleoptera-specific high-throughput screening systems for compounds with ecdysone activity: development of EcR reporter assays using weevil (Anthonomus grandis)-derived cell lines and in silico analysis of ligand binding to A. grandis EcR ligand-binding pocket.

    Science.gov (United States)

    Soin, Thomas; Iga, Masatoshi; Swevers, Luc; Rougé, Pierre; Janssen, Colin R; Smagghe, Guy

    2009-08-01

    Molting in insects is regulated by ecdysteroids and juvenile hormones. Several synthetic non-steroidal ecdysone agonists are on the market as insecticides. These ecdysone agonists are dibenzoylhydrazine (DBH) analogue compounds that manifest their toxicity via interaction with the ecdysone receptor (EcR). Of the four commercial available ecdysone agonists, three (tebufenozide, methoxyfenozide and chromafenozide) are highly lepidopteran specific, one (halofenozide) is used to control coleopteran and lepidopteran insects in turf and ornamentals. However, compared to the very high binding affinity of these DBH analogues to lepidopteran EcRs, halofenozide has a low binding affinity for coleopteran EcRs. For the discovery of ecdysone agonists that target non-lepidopteran insect groups, efficient screening systems that are based on the activation of the EcR are needed. We report here the development and evaluation of two coleopteran-specific reporter-based screening systems to discover and evaluate ecdysone agonists. The screening systems are based on the cell lines BRL-AG-3A and BRL-AG-3C that are derived from the weevil Anthonomus grandis, which can be efficiently transduced with an EcR reporter cassette for evaluation of induction of reporter activity by ecdysone agonists. We also cloned the almost full length coding sequence of EcR expressed in the cell line BRL-AG-3C and used it to make an initial in silico 3D-model of its ligand-binding pocket docked with ponasterone A and tebufenozide.

  19. Integration of IC/EC systems in ITER

    International Nuclear Information System (INIS)

    Gassmann, T.; Beaumont, B.; Baruah, U.K.; Bonicelli, T.; Chiocchio, S.; Cox, D.; Darbos, C.; Decamps, H.; Denisov, G.; Henderson, M.; Kazarian, F.; Lamalle, P.U.; Mukherjee, A.; Rasmussen, D.; Saibene, G.; Sartori, R.; Sakamoto, K.; Tanga, A.

    2010-01-01

    The RF heating and current drive (H and CD) systems that are to be installed in ITER during the construction phase, are the electron cyclotron (EC) and ion cyclotron (IC) systems. They are complex assemblies of high voltage power supplies (HVPS), RF generators, transmission lines and antennas. Their design and integration are constrained by many interfaces, both internal, between the subsystems, and external, with the other ITER systems. In addition, some components must be compatible with a nuclear environment and are classified as Safety Important Component. This paper describes the processes implemented in ITER to ensure proper integration.

  20. Renewables in Transport: Directive 2009/28/EC - Devils in its Details

    International Nuclear Information System (INIS)

    Wilkin, S.

    2009-01-01

    As part of the 3*20 targets reached in December 2008, the EC decided that the EU should, by 2020, source 20% of its Final Energy Consumption (FEC) renewably. Working towards this aim should in general contribute to the primary objective of reducing emissions, but there are two major issues with the implementation of the target in the Transport sector which run the risk of being irrelevant or even counterproductive. Firstly, the constraining stipulation that all Member States should source 10% of their Transport sector FEC renewably will be a struggle for some Member States to achieve, forcing them to invest large amounts of money which would be better spent elsewhere. Secondly, the relevant legislation gives unrepresentative weight to the benefits of Electric Vehicles (EVs), meaning that Member States which invest in EVs may give the illusion of having reached their national renewable targets without actually having done so. This paper is based on EC Directive 2009/28/EC (henceforth referred to as 'the Directive') and the National Renewable Energy Action Plans of Denmark, France, Germany, Italy, Spain, and the UK which were submitted in response. Each EU Member State has an individual target for the proportion of its FEC which is to come from renewable sources in 2020. The targets are based on the countries? existing renewable shares (as shown in Table 1 below) and their supposed capacity for improvement. Together, they give an average EU-wide target of 20% across the 27 Member States. (author)

  1. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Yu Ling

    2018-01-01

    Full Text Available AIM: To investigate the effect of recombinant bovine basic fibroblast growth factor(rb-bFGFeye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: Totally 80 patients with 80 affected eyes undergoing age-related cataract surgery in our hospital from January 2015 to October 2016 were selected as study subjects, and they were randomly divided into control group and experimental group with 40 patients(40 affected eyesin each group. The two groups were treated with hydroxyl indican eye drops and rb-bFGF eye drops, respectively. The clinical curative effect, inflammation related factors \\〖interleukin 6(IL-6, tumor necrosis factor α(TNF-α\\〗, Schirmer test(SⅠt, break-up time(BUTof tear film, corneal sodium fluorescein staining(FLand scores of dry eye symptoms in the two groups were observed. RESULTS: The total treatment effective rate of experimental group after treatment was significantly higher than that of the control group(90.0% vs 72.5%; χ2=4.021, PP>0.05. After treatment, IL-6, TNF-α, SⅠt, FL score and scores of dry eye symptoms in two groups significantly decreased while BUT significantly increased(PPCONCLUSION: In the treatment of patients after age-related cataract after surgery, rb-bFGF eye drops has more advantages over hydroxyl indican eye drops in regulating the expression of inflammatory factors, improving the tear film stability and relieving dry eye symptoms.

  2. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of Hp(3) monitoring. A 2015 review

    International Nuclear Information System (INIS)

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O’Connor, Una

    2015-01-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended. (review)

  3. Dry eye syndrome

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000426.htm Dry eye syndrome To use the sharing features on this page, ... second-hand smoke exposure Cold or allergy medicines Dry eye can also be caused by: Heat or ... Symptoms may include: Blurred vision Burning, itching, ...

  4. Occult intraocular trauma: evaluation of the eye in an austere environment.

    Science.gov (United States)

    Sweet, Patrick H

    2013-03-01

    Physicians deployed to austere environments often encounter the challenge of needing to make clinical decisions based upon rudimentary history and physical examination. These skills, however, can be difficult for many to rely on, with the many subtleties of examining the eye, when they are normally accustomed to relying on sophisticated modalities to establish diagnosis. This case is a model for evaluating eye trauma in an austere or hostile environment. A 25-year-old male U.S. Marine was fired upon at a Mexican Army checkpoint where he sustained glass shrapnel injuries, the most serious being to his right eye. He was taken from a detention facility to a Mexican hospital, where he was evaluated and given the diagnosis of corneal laceration. Twelve hours later, a U.S. Navy physician arrived to evaluate the patient; he was allowed limited access to the patient. His ophthalmologic examination revealed a closed corneal laceration on the right eye, worse than 20/800 vision, absent red reflex, and obscured funduscopic examination. These findings made it impossible to rule out globe penetration. The patient was released 48 h later to a U.S. Naval Hospital, where intraocular foreign bodies were confirmed by imaging and he was taken to emergency surgery. This case illustrates that even under austere conditions, a focused history and evaluation can reveal the likelihood of occult intraocular foreign body, thereby triaging the patient for emergency surgery. Published by Elsevier Inc.

  5. The Tromsø Eye Study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Erke, Maja G; von Hanno, Therese

    2013-01-01

    Purpose:  To describe the study design and methodology of the Tromsø Eye Study (TES), and to describe visual acuity and refractive error in the study population. Methods:  The Tromsø Eye Study is a sub-study of the Tromsø Study, a population-based multipurpose longitudinal study in the municipality...... of Tromsø, Norway. The Tromsø Eye Study was a part of the sixth survey of the Tromsø Study, conducted from October 2007 through December 2008. The eye examination included information on self-reported eye diseases, assessment of visual acuity and refractive errors, retinal photography and optical coherence...

  6. [Knockdown of NEDD9 inhibits the proliferation, invasion and migration of esophageal carcinoma EC109 cells].

    Science.gov (United States)

    Zhang, Wen; Li, Shaojun; Zhao, Yunlong; Guo, Nannan; Li, Yingjie

    2016-12-01

    Objective To observe the expression of the neural precursor cell expressed, developmentally down-regulated 9 (NEDD9) in esophageal cancer, to investigate the impact of decreased expression of NEDD9 on invasion and migration, and to explicit the function of NEDD9 in EC109 human esophageal cancer cell line. Methods Immunohistochemical staining was used to detect the expression of NEDD9 in human esophageal cancer tissues and paracancerous normal tissues. RNA interfering (RNAi) was used to knockdown NEDD9 in EC109 cells. The interference efficiency was detected by reverse transcription PCR (RT-PCR) and Western blot analysis. Cell proliferation was determined by MTT assay and the invasion and migration abilities of EC109 cells were monitored by Transwell TM assay. The protein levels of proliferating cell nuclear antigen (PCNA), Bax and Bcl-2 were tested by Western blotting. Results The positive expression rate of NEDD9 in esophageal carcinoma tissues was significantly higher compared with that in the paracancerous tissues. After NEDD9 expression was successfully downregulated in EC109 cells by siRNA, the proliferation, invasion and migration rates in transfection group were significantly lower than those in control group; meanwhile, the expression of Bcl-2 was reduced and Bax expression was enhanced. Conclusion The protein expression level of NEDD9 is higher in esophageal carcinoma tissues than that in adjacent normal tissues. Knockdown of NEDD9 expression can restrain the proliferation, invasion and migration of EC109 cells.

  7. (EC+β+) decay of 130Ce

    International Nuclear Information System (INIS)

    Xu Shuwei; Zhang Tianmei; Xie Yuanxiang; Ma Ruichang; Ge Yuanxiu; Guo Yingxiang; Wang Chunfang; Li Zhankui; Guo Bing; Xing Jianping; Guo Tianrui; Zhu Shaofei; Xu Wang; Du Jinzhou

    1996-01-01

    The nuclide 130 Ce was produced by a ( 16 O, 4n) reaction on an enriched 118 Sn target. Reaction products were transported to a shielded location by using a helium-jet tape transport system. A 22.9 min activity in chemically separated cerium sample was identified as 130 Ce. The (EC+β + ) decay scheme of 130 Ce was proposed for the first time. This scheme includes 108 γ-lines, 107 γ-lines among them being new. More than 13 1 + low-lying states of 130 La are populated in the decay of 130 Ce. Two new isomers with half-life of 77±10 ns and 17±5 ns were observed by means of delayed γ-γ coincidence measurements. (orig.). With 5 figs., 3 tabs

  8. Effects of ballates, step aerobics, and walking on balance in women aged 50-75 years.

    Science.gov (United States)

    Clary, Sarah; Barnes, Cathleen; Bemben, Debra; Knehans, Allen; Bemben, Michael

    2006-01-01

    This study examined the effectiveness of Ballates training (strengthening of the central core musculature by the inception of balance techniques) compared to more traditional exercise programs, such as step aerobics and walking, on balance in women aged 50- 75 years. Participants were randomly assigned to one of three supervised training groups (1 hour/day, 3 days/week, 13 weeks), Ballates (n = 12), step aerobics (n = 17), or walking (n =15). Balance was measured by four different methods (modified Clinical Test for the Sensory Interaction on Balance - mCTSIB; Unilateral Stance with Eyes Open - US-EO or Eyes Closed - US-EC; Tandem Walk - TW; Step Quick Turn - SQT) using the NeuroCom Balance Master. A 2-way (Group and Trial) repeated measures ANOVA and post-hoc Bonferroni Pair-wise Comparisons were used to evaluate changes in the dependent variables used to describe stability and balance (sway velocity, turn sway, speed, and turn time). Measures of static postural stability and dynamic balance were similar for the three groups prior to training. Following the different exercise interventions, sway velocity on firm and foam surfaces (mCTSIB) with eyes closed (p risk of fall.

  9. A new verification film system for routine quality control of radiation fields: Kodak EC-L

    International Nuclear Information System (INIS)

    Hermann, A.; Bratengeier, K.; Priske, A.; Flentje, M.

    2000-01-01

    Background: The use of modern irradiation techniques requires better verification films for determining set-up deviations and patient movements during the course of radiation treatment. This is an investigation of the image quality and time requirement of a new verification film system compared to a conventional portal film system. Material and Methods: For conventional verifications we used Agfa Curix HT 1000 films which were compared to the new Kodak EC-L film system. 344 Agfa Curix HT 1000 and 381 Kodak EC-L portal films of different tumor sites (prostate, rectum, head and neck) were visually judged on a light box by 2 experienced physicians. Subjective judgement of image quality, masking of films and time requirement were checked. Results: In this investigation 68% of 175 Kodak EC-L ap/pa-films were judged 'good', only 18% were classified 'moderate' or 'poor' 14%, but only 22% of 173 conventional ap/pa verification films (Agfa Curix HT 1000) were judged to be 'good'. Conclusions: The image quality, detail perception and time required for film inspection of the new Kodak EC-L film system was significantly improved when compared with standard portal films. They could be read more accurately and the detection of set-up deviation was facilitated. (orig.) [de

  10. CLOSING MACULAR HOLES WITH "MACULAR PLUG" WITHOUT GAS TAMPONADE AND POSTOPERATIVE POSTURING.

    Science.gov (United States)

    Chakrabarti, Meena; Benjamin, Preethi; Chakrabarti, Keya; Chakrabarti, Arup

    2017-03-01

    To investigate the surgical results of macular hole surgery without gas tamponade or postoperative posturing in patients with Stage 3 and Stage 4 macular holes with ≥500 μm mean base diameter. Retrospective interventional case series. Twenty-six patients with Stage 3 and Stage 4 macular holes. Twenty-six eyes of 26 patients with Stage 3 and Stage 4 macular holes and a mean base diameter of 892.8 ± 349 μm underwent pars plana 23-gauge vitrectomy with broad internal limiting membrane peel (ILM peel), inverted ILM flap repositioning (ILMR), and use of autologous gluconated blood clumps as a macular plug to close the macular hole. No fluid-air exchange, endotamponade, or postoperative posturing was used. The subjects were followed up for 12 months. The anatomical outcome of the procedure was evaluated by fundus examination and optical coherence tomography. Spectral domain optical coherence tomography was used to study the restoration of the outer retinal layer integrity in the postoperative period. The preoperative and postoperative best-corrected visual acuities in logMAR units were compared to evaluate functional outcome. Macular hole closure and best-corrected visual acuity before and after surgery. Twenty-six patients with mean age 62.8 ± 7.3 years, preoperative median best-corrected visual acuity 6/60 (1.0 logMAR units), and a mean base diameter of 892.8 ± 349 μm underwent surgery to close macular holes without gas tamponade or postoperative posturing. Twenty patients (76.9%) were phakic. Twenty eyes (76.92%) had Stage 3 macular holes and 6 eyes (23.10%) had Stage 4 macular holes. After a single surgery, hole closure was achieved in 100% of eyes. The median best-corrected visual acuity improved from 6/60 (1.0 logMAR units) to 6/18 (0.50 logMAR units) (P hole closure with statically significant functional improvement for large Stage 3 and Stage 4 macular holes.

  11. Influence of gap and overlap paradigms on saccade latencies and vergence eye movements in seven-year-old children.

    Science.gov (United States)

    Bucci, Maria Pia; Pouvreau, Nathalie; Yang, Qing; Kapoula, Zoï

    2005-07-01

    The latency of eye movements is influenced by the fixation task; when the fixation stimulus is switched off before the target presentation (gap paradigm) the latency becomes short and express movements occur. In contrast, when the fixation stimulus remains on when the target appears (overlap paradigm), eye movement latency is longer. Several previous studies have shown increased rates of express saccades in children; however the presence of an express type of latency for vergence and combined movements in children has never been explored. The present study examines the effects of the gap and the overlap paradigms on horizontal saccades at far (150 cm) and at close (20 cm) viewing distances, on vergence along the median plane, and on saccades combined with convergence or divergence in 15 normal seven-year-old children. The results show that the gap paradigm produced shorter latency for all eye movements than the overlap paradigm, but the difference was only significant for saccades at close viewing distances, for divergence (pure and combined), and for saccades combined with vergence. The gap paradigm produced significantly higher rates of express latencies for saccades at close viewing distances, for divergence, and for saccades combined with divergence; in contrast, the frequencies of express latencies for saccades at far viewing distances and for convergence (pure or combined) were similar in the gap and the overlap paradigms. Interestingly, the rate of anticipatory latencies (gap paradigm. Our collective findings suggest that the initiation of saccades at close viewing distances and of divergence is more reflexive, particularly in the gap paradigm. The finding of frequent anticipatory divergence that occurs at similar rates for seven-year-old children (this study) and for adults (Coubard et al., 2004, Exp Brain Res 154:368-381) indicates that predictive initiation of divergence is dominant.

  12. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  13. Eye-movements and ongoing task processing.

    Science.gov (United States)

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory.

  14. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    2010-10-12

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.  Created: 10/12/2010 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 10/13/2010.

  15. Neuropathic pain and dry eye.

    Science.gov (United States)

    Galor, Anat; Moein, Hamid-Reza; Lee, Charity; Rodriguez, Adriana; Felix, Elizabeth R; Sarantopoulos, Konstantinos D; Levitt, Roy C

    2018-01-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. Its epidemiology and clinical presentation have many similarities with neuropathic pain outside the eye. This review highlights the similarities between dry eye and neuropathic pain, focusing on clinical features, somatosensory function, and underlying pathophysiology. Implications of these similarities on the diagnosis and treatment of dry eye are discussed. Published by Elsevier Inc.

  16. 620 ASSESSMENT OF HEAVY METALS, pH AND EC IN EFFLUENT ...

    African Journals Online (AJOL)

    Osondu

    evaluated metals were Cu, Fe, Ni, Mn, Cr, Zn, Cd, Co, and Ag. The pH, EC, TDS, DO ... heavy metals, but the high heavy metal concentrations in the soil could seriously ... Key words: Heavy metals, AAS, contamination, floriculture and effluents.

  17. Girls with generalized joint hypermobility display changed muscle activity and postural sway during static balance tasks

    DEFF Research Database (Denmark)

    Juul-Kristensen, B; Johansen, Kl; Hendriksen, P

    2016-01-01

    OBJECTIVES: To study knee muscle activity and static postural sway in girls with generalized joint hypermobility (GJH). METHOD: Sixteen girls with GJH and 11 girls with non-GJH (NGJH) aged 14 years, randomly recruited among schoolchildren, participated in this study. GJH inclusion criteria were......: Beighton score minimum 6/9 and one hypermobile knee; for NGJH: Beighton score maximum 5/9 and no knees with hypermobility. The participants performed a static two-legged balance test with eyes open (2EO) and eyes closed (2EC) and a one-legged stance test with eyes open (1EO). Postural sway (centre......) of Q, H, and G muscle activity was calculated. Knee function was self-reported using the Knee Injury and Osteoarthritis Outcome Score for children (KOOS-Child). RESULTS: GJH had a significantly lower lateral HQ CCI and a higher medial/lateral HQ CCI ratio in all balance tasks. Group mean EMG varied...

  18. Effects of resting state condition on reliability, trait specificity, and network connectivity of brain function measured with arterial spin labeled perfusion MRI.

    Science.gov (United States)

    Li, Zhengjun; Vidorreta, Marta; Katchmar, Natalie; Alsop, David C; Wolf, Daniel H; Detre, John A

    2018-06-01

    Resting state fMRI (rs-fMRI) provides imaging biomarkers of task-independent brain function that can be associated with clinical variables or modulated by interventions such as behavioral training or pharmacological manipulations. These biomarkers include time-averaged regional brain function as manifested by regional cerebral blood flow (CBF) measured using arterial spin labeled (ASL) perfusion MRI and correlated temporal fluctuations of function across brain networks with either ASL or blood oxygenation level dependent (BOLD) fMRI. Resting-state studies are typically carried out using just one of several prescribed state conditions such as eyes closed (EC), eyes open (EO), or visual fixation on a cross-hair (FIX), which may affect the reliability and specificity of rs-fMRI. In this study, we collected test-retest ASL MRI data during 4 resting-state task conditions: EC, EO, FIX and PVT (low-frequency psychomotor vigilance task), and examined the effects of these task conditions on reliability and reproducibility as well as trait specificity of regional brain function. We also acquired resting-state BOLD fMRI under FIX and compared the network connectivity reliabilities between the four ASL conditions and the BOLD FIX condition. For resting-state ASL data, EC provided the highest CBF reliability, reproducibility, trait specificity, and network connectivity reliability, followed by EO, while FIX was lowest on all of these measures. PVT demonstrated lower CBF reliability, reproducibility and trait specificity than EO and EC. Overall network connectivity reliability was comparable between ASL and BOLD. Our findings confirm ASL CBF as a reliable, stable, and consistent measure of resting-state regional brain function and support the use of EC or EO over FIX and PVT as the resting-state condition. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  19. The Eyes Are the Windows to the Mind: Direct Eye Gaze Triggers the Ascription of Others' Minds.

    Science.gov (United States)

    Khalid, Saara; Deska, Jason C; Hugenberg, Kurt

    2016-12-01

    Eye gaze is a potent source of social information with direct eye gaze signaling the desire to approach and averted eye gaze signaling avoidance. In the current work, we proposed that eye gaze signals whether or not to impute minds into others. Across four studies, we manipulated targets' eye gaze (i.e., direct vs. averted eye gaze) and measured explicit mind ascriptions (Study 1a, Study 1b, and Study 2) and beliefs about the likelihood of targets having mind (Study 3). In all four studies, we find novel evidence that the ascription of sophisticated humanlike minds to others is signaled by the display of direct eye gaze relative to averted eye gaze. Moreover, we provide evidence suggesting that this differential mentalization is due, at least in part, to beliefs that direct gaze targets are more likely to instigate social interaction. In short, eye contact triggers mind perception. © 2016 by the Society for Personality and Social Psychology, Inc.

  20. Analysis of Well ER-EC-7 Testing, Western Pahute Mesa - Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-7 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program was documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-7 Data Report for Development and Hydraulic Testing.

  1. Analysis of Well ER-EC-8 testing, Western Pahute Mesa-Oasis Valley FY 2000 testing program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-8 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa-Oasis Valley, Well ER-EC-8 Data Report for development and Hydraulic Testing.

  2. Analysis of Well ER-EC-4 Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-4 during the Western Pahute Mesa-Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-4 Data Report for Development and Hydraulic Testing.

  3. Analysis of Well ER-EC-5 Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-5 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-5 Data Report for Development and Hydraulic Testing.

  4. Analysis of Well ER-EC-6 Testing, Western Pahute Mesa - Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-6 during the Western Pahute Mesa-Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa-Oasis Valley, Well ER-EC-6 Data Report for Development and Hydraulic Testing.

  5. Analysis of Well ER-EC-1 Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-1 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-1 Data Report for Development and Hydraulic Testing.

  6. About the Eye

    Medline Plus

    Full Text Available ... luh) is the small, sensitive area of the retina needed for central vision. It contains the fovea. Lens is the clear part of the eye behind the iris that helps to focus light on the retina. It allows the eye to focus on both ...

  7. Capability and limits of EC policy and instruments for protection of the environment

    International Nuclear Information System (INIS)

    Jarass, H.D.; Neumann, L.F.; Pastowski, A.; Ruhr, H.J. von der; Schreiber, F.

    1994-01-01

    The authors who contributed to this compilation of studies start from different points of view in their approaches towards describing the existing (or desirable) balance between centralised and decentralised frameworks and instruments of the EC policy for protection of the environment: A total harmonisation of environmental protection standards would be inconsistent with the principles of competition and, in terms of environmental protection, would rather foster a climate tending to be hostile to innovation. The impetus given by the EC in support of free mobility in the transport sector of the internal market on the other hand ought to be flanked by mandatory ecological standards. Adhering to the economic theory of federalism would mean to decide for a high degree of decentralisation, which in turn does not seem to be altogether appropriate in view of the large scope of impact of environmental damage and the mutual ecological dependence of EC member states. A more centralised regulatory competence has to be accompanied by correspondingly strong, democratic institutions in order to fulfill the principles of constitutional law. The priority given to the principle of subsidiarity in the compromise laid down in the Treaty of Maastricht needs to be given concrete shape [de

  8. Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    S. Catalan

    2016-01-01

    Full Text Available Purpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n=22 and normal fellow eyes (n=22 in patients with asymmetric keratoconus and normal eyes (n=104 in healthy subjects. Areas under the curve (AUC of receiver operator characteristic (ROC curves for each variable were compared across groups to indicate their discrimination capacity. Results. Three variables were found to differ significantly between fellow eyes and normal eyes (all p<0.05: minimum corneal thickness, thinnest corneal point, and central corneal thickness. These variables combined showed a high discrimination power to differentiate fellow eyes from normal eyes indicated by an AUC of 0.840 (95% CI: 0.762–0.918. Conclusions. Our findings indicate that topographically normal fellow eyes in patients with very asymmetric keratoconus differ from the eyes of healthy individuals in terms of their corneal epithelial and pachymetry maps. This type of information could be useful for an early diagnosis of keratoconus in topographically normal eyes.

  9. Radioactivity of neutron-irradiated cat's-eye chrysoberyls

    Energy Technology Data Exchange (ETDEWEB)

    Tang, S.M. E-mail: phytsm@leonis.nus.edu.sg; Tay, T.S

    1999-04-02

    The recent report of marketing of radioactive chrysoberyl cat's-eyes in South-East Asian markets has led us to use an indirect method to estimate the threat to health these color-enhanced gemstones may pose if worn close to skin. We determined the impurity content of several cat's-eye chrysoberyls from Indian States of Orissa and Kerala using PIXE, and calculated the radioactivity that would be generated from these impurities and the constitutional elements if a chrysoberyl was irradiated by neutrons in a nuclear reactor for color enhancement. Of all the radioactive nuclides that could be created by neutron irradiation, only four ({sup 46}Sc, {sup 51}Cr, {sup 54}Mn and {sup 59}Fe) would not have cooled down within a month after irradiation to the internationally accepted level of specific residual radioactivity of 2 nCi/g. The radioactivity of {sup 46}Sc, {sup 51}Cr and {sup 59}Fe would only fall to this safe limit after 15 months and that of {sup 54}Mn could remain above this limit for several years.

  10. Estrutura de comunidades em transições ambientais : lagartos no ecótono Cerrado-Amazônia

    OpenAIRE

    Dantas, Pedro Tourinho

    2014-01-01

    Os limites ecológicos desempenham um papel crucial no fluxo de espécies, de genes e 2 nutrientes entre áreas adjacentes. Os limites não apenas separam, mas também conectam 3 estas áreas, agindo como filtros de permeabilidade variável. A estrutura das comunidades 4 varia com a proximidade do ecótono e a riqueza de espécies no ecótono pode ser maior que, 5 menor que, ou intermediária entre as áreas adjacentes. Aqui, eu investigo como o ecótono 6 isola a Amazônia e o Cerrado, atuando como um fil...

  11. Stability of the Gel Electrolyte PAN : EC : PC : LICF3SO3 towards Lithium

    DEFF Research Database (Denmark)

    Perera, Kumudu; Dissanayake, M.A.K.L.; Skaarup, Steen

    2006-01-01

    The stability of the gel electrolyte consisting of polyacrylonitrile (PAN), ethylene carbonate (EC), propylene carbonate (PC) and lithium trifluoromethanesulfonate (LiCF3SO3 – LiTF) towards metallic lithium was investigated using the time evolution of impedance plots. Symmetric cells of the form Li...... / PAN : EC : PC: LiTF / Li were assembled and impedance data were collected at room temperature for one week. A clear indication of growth of a resistive layer could be seen. The electrolyte resistance remained constant. The growth of the passivation layer became constant after first two days...

  12. Automated classifiers for early detection and diagnosis of retinopathy in diabetic eyes.

    Science.gov (United States)

    Somfai, Gábor Márk; Tátrai, Erika; Laurik, Lenke; Varga, Boglárka; Ölvedy, Veronika; Jiang, Hong; Wang, Jianhua; Smiddy, William E; Somogyi, Anikó; DeBuc, Delia Cabrera

    2014-04-12

    Artificial neural networks (ANNs) have been used to classify eye diseases, such as diabetic retinopathy (DR) and glaucoma. DR is the leading cause of blindness in working-age adults in the developed world. The implementation of DR diagnostic routines could be feasibly improved by the integration of structural and optical property test measurements of the retinal structure that provide important and complementary information for reaching a diagnosis. In this study, we evaluate the capability of several structural and optical features (thickness, total reflectance and fractal dimension) of various intraretinal layers extracted from optical coherence tomography images to train a Bayesian ANN to discriminate between healthy and diabetic eyes with and with no mild retinopathy. When exploring the probability as to whether the subject's eye was healthy (diagnostic condition, Test 1), we found that the structural and optical property features of the outer plexiform layer (OPL) and the complex formed by the ganglion cell and inner plexiform layers (GCL + IPL) provided the highest probability (positive predictive value (PPV) of 91% and 89%, respectively) for the proportion of patients with positive test results (healthy condition) who were correctly diagnosed (Test 1). The true negative, TP and PPV values remained stable despite the different sizes of training data sets (Test 2). The sensitivity, specificity and PPV were greater or close to 0.70 for the retinal nerve fiber layer's features, photoreceptor outer segments and retinal pigment epithelium when 23 diabetic eyes with mild retinopathy were mixed with 38 diabetic eyes with no retinopathy (Test 3). A Bayesian ANN trained on structural and optical features from optical coherence tomography data can successfully discriminate between healthy and diabetic eyes with and with no retinopathy. The fractal dimension of the OPL and the GCL + IPL complex predicted by the Bayesian radial basis function network provides better

  13. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen

    2011-01-01

    Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  14. Comparing search patterns in digital breast tomosynthesis and full-field digital mammography: an eye tracking study.

    Science.gov (United States)

    Aizenman, Avi; Drew, Trafton; Ehinger, Krista A; Georgian-Smith, Dianne; Wolfe, Jeremy M

    2017-10-01

    As a promising imaging modality, digital breast tomosynthesis (DBT) leads to better diagnostic performance than traditional full-field digital mammograms (FFDM) alone. DBT allows different planes of the breast to be visualized, reducing occlusion from overlapping tissue. Although DBT is gaining popularity, best practices for search strategies in this medium are unclear. Eye tracking allowed us to describe search patterns adopted by radiologists searching DBT and FFDM images. Eleven radiologists examined eight DBT and FFDM cases. Observers marked suspicious masses with mouse clicks. Eye position was recorded at 1000 Hz and was coregistered with slice/depth plane as the radiologist scrolled through the DBT images, allowing a 3-D representation of eye position. Hit rate for masses was higher for tomography cases than 2-D cases and DBT led to lower false positive rates. However, search duration was much longer for DBT cases than FFDM. DBT was associated with longer fixations but similar saccadic amplitude compared with FFDM. When comparing radiologists' eye movements to a previous study, which tracked eye movements as radiologists read chest CT, we found DBT viewers did not align with previously identified "driller" or "scanner" strategies, although their search strategy most closely aligns with a type of vigorous drilling strategy.

  15. 76 FR 30987 - Termination of Action and Further Monitoring in Connection With the EC-Beef Hormones Dispute

    Science.gov (United States)

    2011-05-27

    ... Connection With the EC-Beef Hormones Dispute AGENCY: Office of the United States Trade Representative. ACTION... Hormones dispute. In January 2009, the Trade Representative announced a determination to modify the list of...) in the EC-Beef Hormones dispute. The MOU provides for the EU to make phased increases in market...

  16. Real-Time Control of a Video Game Using Eye Movements and Two Temporal EEG Sensors

    Directory of Open Access Journals (Sweden)

    Abdelkader Nasreddine Belkacem

    2015-01-01

    Full Text Available EEG-controlled gaming applications range widely from strictly medical to completely nonmedical applications. Games can provide not only entertainment but also strong motivation for practicing, thereby achieving better control with rehabilitation system. In this paper we present real-time control of video game with eye movements for asynchronous and noninvasive communication system using two temporal EEG sensors. We used wavelets to detect the instance of eye movement and time-series characteristics to distinguish between six classes of eye movement. A control interface was developed to test the proposed algorithm in real-time experiments with opened and closed eyes. Using visual feedback, a mean classification accuracy of 77.3% was obtained for control with six commands. And a mean classification accuracy of 80.2% was obtained using auditory feedback for control with five commands. The algorithm was then applied for controlling direction and speed of character movement in two-dimensional video game. Results showed that the proposed algorithm had an efficient response speed and timing with a bit rate of 30 bits/min, demonstrating its efficacy and robustness in real-time control.

  17. Molecular characterization of EcCIPK24 gene of finger millet (Eleusine coracana) for investigating its regulatory role in calcium transport.

    Science.gov (United States)

    Chinchole, Mahadev; Pathak, Rajesh Kumar; Singh, Uma M; Kumar, Anil

    2017-08-01

    Finger millet grains contain exceptionally high levels of calcium which is much higher compared to other cereals and millets. Since calcium is an important macronutrient in human diet, it is necessary to explore the molecular basis of calcium accumulation in the seeds of finger millet. CIPK is a calcium sensor gene, having role in activating Ca 2+ exchanger protein by interaction with CBL proteins. To know the role of EcCIPK24 gene in seed Ca 2+ accumulation, sequence is retrieved from the transcriptome data of two finger millet genotypes GP1 (low Ca 2+ ) and GP45 (high Ca 2+ ), and the expression was determined through qRT-PCR. The higher expression was found in root, shoot, leaf and developing spike tissue of GP45 compared to GP1; structural analysis showed difference of nine SNPs and one extra beta sheet domain as well as differences in vacuolar localization was predicted; besides, the variation in amino acid composition among both the genotypes was also investigated. Molecular modeling and docking studies revealed that both EcCBL4 and EcCBL10 showed strong binding affinity with EcCIPK24 (GP1) compared to EcCIPK24 (GP45). It indicates a genotypic structural variation, which not only affects the affinity but also calcium transport efficiency after interaction of CIPK-CBL with calcium exchanger ( Ec CAX1b) to pull calcium in the vacuole. Based on the expression and in silico study, it can be suggested that by activating EcCAX1b protein, EcCIPK24 plays an important role in high seed Ca 2+ accumulation.

  18. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Cour, Morten la

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling...

  19. Clinical effect of 1g/L anthocyanin eye-patch for mild and moderate dry eye

    Directory of Open Access Journals (Sweden)

    Ke-Hua Wang

    2018-05-01

    Full Text Available AIM:To evaluate the clinic efficacy of 1g/L anthocyanin eye-patch for mild and moderate dry eye. METHODS: In this prospective and multicenter study, a total of 320 cases(640 eyeswith mild and moderate dry eye were enrolled from 8 Aier Eye Hospitals in Changsha, Chongqing, Wuhan and so on from October 2016 to April 2017. The patients were assigned to eye patch group(160 casesand artificial tears group(160 casesbased on random number table. The patients in eye-patch group used 1g/L of anthocyanin eye-patch for more than 6h during night sleep, while the patients in artificial tears group used polyvinyl alcohol eye drops for 4 times per day. The evaluation of symptoms and signs were conducted on 1d before the treatment and 14d after the treatment. The evaluation of symptoms adopted the Ocular Surface Disease Index(OSDI, while the observation of signs included tear secretion test(Schirmer Ⅰ test, SⅠt, first noninvasive tear breakup time(NITBUTfas well as average noninvasive tear breakup time(NITBUTavmeasured by Oculus ocular surface analyser. RESULTS: OSDI score, NITBUTf and NITBUTav in the two groups after treatment were significantly improved compared with that before treatment, and the difference had a statistical significance(PP>0.05. There was no significant difference in OSDI score, NITBUTf, NITBUTav and SⅠt between the two groups after treatment(P>0.05.CONCLUSION: The 1g/L anthocyanin eye-patch has similar efficacy with artificial tears for mild and moderate dry eye, which can effectively improve the symptoms and tear film stability.

  20. Evaluation of treatment for dry eye with 2-hydroxyestradiol using a dry eye rat model.

    Science.gov (United States)

    Higuchi, Akihiro; Oonishi, Erina; Kawakita, Tetsuya; Tsubota, Kazuo

    2016-01-01

    2-hydroxy estradiol (2-OHE2) is a catechol derivative of 17β -Estradiol (E2) and it is synthesized from E2 catalyzed by cytochrome P4501A1. Previous studies reported that 2-OHE2 is a physiologic antioxidant in lipoproteins, liver microsomes, and the brain. Catechol derivatives show an anti-inflammatory effect through the inhibition of prostaglandin endoperoxide synthase (PGS) activity. Corneal erosion caused by dry eye is related to an increase in oxidative stress and inflammation in ocular surface cells. We investigated the therapeutic effects of 2-OHE2 on corneal damage caused by dry eye. Steroidal radical scavenging activity was confirmed through the electron spin resonance (ESR) method. PGS activity was measured using the COX Fluorescent Activity Assay Kit. To evaluate the effect of 2-OHE2 on the treatment for dry eye, 2-OHE2 was applied as an eye drop experiment using dry eye model rats. 2-OHE2 scavenged tyrosyl radical and possibly suppressed oxidative stress in corneal epithelial cells. In addition, 2-OHE2 inhibited PGS activity, and 2-OHE2 is probably a competitive inhibitor of PGS. Corneal PGS activity was upregulated in the dry eye group. Therefore, 2-OHE2 eye drops improved corneal erosion in dry eye model rats. 2-OHE2 is a candidate for the treatment of dry eye through the suppression of inflammation and oxidative stress in the cornea.