WorldWideScience

Sample records for eye study research

  1. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    Science.gov (United States)

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  2. Longitudinal Andhra Pradesh Eye Disease Study: rationale, study design and research methodology.

    Science.gov (United States)

    Khanna, Rohit C; Murthy, Gudlavalleti Vs; Marmamula, Srinivas; Mettla, Asha Latha; Giridhar, Pyda; Banerjee, Seema; Shekhar, Konegari; Chakrabarti, Subhabrata; Gilbert, Clare; Rao, Gullapalli N

    2016-03-01

    The rationale, objectives, study design and procedures for the longitudinal Andhra Pradesh Eye Disease Study are described. A longitudinal cohort study was carried out. Participants include surviving cohort from the rural component of Andhra Pradesh Eye Disease Study. During 1996-2000, Andhra Pradesh Eye Disease Survey was conducted in three rural (n = 7771) and one urban (n = 2522) areas (now called Andhra Pradesh Eye Disease Study 1). In 2009-2010, a feasibility exercise (Andhra Pradesh Eye Disease Study 2) for a longitudinal study (Andhra Pradesh Eye Disease Study 3) was undertaken in the rural clusters only, as urban clusters no longer existed. In Andhra Pradesh Eye Disease Study 3, a detailed interview will be carried out to collect data on sociodemographic factors, ocular and systemic history, risk factors, visual function, knowledge of eye diseases and barriers to accessing services. All participants will also undergo a comprehensive eye examination including photography of lens, optic disc and retina, Optic Coherence Tomography of the posterior segment, anthropometry, blood pressure and frailty measures. Measures include estimates of the incidence of visual impairment and age-related eye disease (lens opacities, glaucoma and age-related macular degeneration) and the progression of eye disease (lens opacities and myopia) and associated risk factors. Of the 7771 respondents examined in rural areas in Andhra Pradesh Eye Disease Study 1, 5447 (70.1%) participants were traced in Andhra Pradesh Eye Disease Study 2. These participants will be re-examined. Andhra Pradesh Eye Disease Study 3 will provide data on the incidence and progression of visual impairment and major eye diseases and their associated risk factors in India. The study will provide further evidence to aid planning eye care services. © 2015 Royal Australian and New Zealand College of Ophthalmologists.

  3. Eye-tracking research in computer-mediated language learning

    NARCIS (Netherlands)

    Michel, Marije; Smith, Bryan

    2017-01-01

    Though eye-tracking technology has been used in reading research for over 100 years, researchers have only recently begun to use it in studies of computer-assisted language learning (CALL). This chapter provides an overview of eye-tracking research to date, which is relevant to computer-mediated

  4. Low Vision Research at the Schepens Eye Research Institute

    National Research Council Canada - National Science Library

    D'Amore, Patricia

    2003-01-01

    This research proposal, Low Vision at the Schepens Eye Research Institute, is a collaborative effort on the part of four Investigators at the Institute whose goal is to advance the studies on low vision...

  5. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    Science.gov (United States)

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  6. NASA supporting studies for microgravity research on eye movements

    Science.gov (United States)

    Cohen, Bernard

    1990-01-01

    The purpose of the work on this project was to provide support for ground-based studies on the effects of gravity on eye movements. The effects of microgravity on the optokinetic eye movements of humans are investigated. OKN was induced by having subjects watch 3.3 deg stripes moving at 35 deg/s for 45 s in a binocular, head-fixed apparatus. The field (hor., 88 deg; vert., 72 deg), was rotated about axes that were upright or tilted 45 deg or 90 deg. The head was upright or tilted 45 deg on the body. Head-horizontal (yaw axis) and head-vertical (pitch axis) components of OKN were recorded with electro-oculography (EOG). Slow phase velocity vectors were determined relative to gravity. With the head upright, the axis of eye rotation during yaw axis OKN was coincident with the stimulus axis and the spatial vertical. With the head tilted 45 deg on the body, a persistent vertical component of eye velocity developed during yaw axis stimulation, and there was an average shift of the axis of eye rotation toward the spatial vertical of approximately 18 deg in six subjects. During oblique optokinetic stimulation with the head upright, the axis of eye rotation shifted 12 deg toward the spatial vertical. When the head was tilted, the axis of eye rotation rotated to the other side of the spatial vertical by 5.4 deg during the same oblique stimulation. This counter-rotation of the axis of eye rotation is similar to the 'Muller (E) effect', in which the perception of the upright counter-rotates to the opposite side of the spatial vertical when subjects are tilted in darkness. The data were simulated by a model of OKN. Despite the short OKAN time constants, strong horizontal to vertical cross-coupling was produced if the horizontal and vertical time constants were in proper ratio, and there was no suppression of nystagmus orthogonal to the stimulus direction. This shows that the spatial orientation of OKN can be due to a restructuring of the system matrix of velocity storage as a

  7. The medical eye: Conclusions from eye tracking research on expertise development in medicine

    NARCIS (Netherlands)

    Jarodzka, Halszka; Jaarsma, Thomas; Dewhurst, Richard; Boshuizen, Els

    2013-01-01

    Jarodzka, H., Jaarsma, T., Dewhurst, R., & Boshuizen, H. P. A. (2012, October). The medical eye: Conclusions from eye tracking research on expertise development in medicine. Paper presented at the New tools and practices for seeing and learning in medicine ’12, University of Turku, Turku, Finland.

  8. The chick eye in vision research: An excellent model for the study of ocular disease.

    Science.gov (United States)

    Wisely, C Ellis; Sayed, Javed A; Tamez, Heather; Zelinka, Chris; Abdel-Rahman, Mohamed H; Fischer, Andy J; Cebulla, Colleen M

    2017-11-01

    The domestic chicken, Gallus gallus, serves as an excellent model for the study of a wide range of ocular diseases and conditions. The purpose of this manuscript is to outline some anatomic, physiologic, and genetic features of this organism as a robust animal model for vision research, particularly for modeling human retinal disease. Advantages include a sequenced genome, a large eye, relative ease of handling and maintenance, and ready availability. Relevant similarities and differences to humans are highlighted for ocular structures as well as for general physiologic processes. Current research applications for various ocular diseases and conditions, including ocular imaging with spectral domain optical coherence tomography, are discussed. Several genetic and non-genetic ocular disease models are outlined, including for pathologic myopia, keratoconus, glaucoma, retinal detachment, retinal degeneration, ocular albinism, and ocular tumors. Finally, the use of stem cell technology to study the repair of damaged tissues in the chick eye is discussed. Overall, the chick model provides opportunities for high-throughput translational studies to more effectively prevent or treat blinding ocular diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Research on Eye Movement Tracking in ESL Reading

    Directory of Open Access Journals (Sweden)

    Wenlian ZHAN

    2014-06-01

    Full Text Available Eye movement behavior in reading can reflect on-line cognitive process. Through the on-line measure of eye movement, under relatively natural reading condition, data of the reader’ s eye movement in the text can be obtained in processing information, and thus help to reveal the internal cognitive mechanisms in reading. With the development of intelligentization, serialization and portable direction in eye tracker, there exist great number of studies on eye movement tracking, but studies on eye movement features in ESL reading are rare. In such circumstances, this paper mainly illustrates eye movement patterns, the relationship between eye movement and perceptual processing, and eye movement control in ESL reading.

  10. The Tromsø Eye Study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Erke, Maja G; von Hanno, Therese

    2013-01-01

    Purpose:  To describe the study design and methodology of the Tromsø Eye Study (TES), and to describe visual acuity and refractive error in the study population. Methods:  The Tromsø Eye Study is a sub-study of the Tromsø Study, a population-based multipurpose longitudinal study in the municipality...... of Tromsø, Norway. The Tromsø Eye Study was a part of the sixth survey of the Tromsø Study, conducted from October 2007 through December 2008. The eye examination included information on self-reported eye diseases, assessment of visual acuity and refractive errors, retinal photography and optical coherence...

  11. Using Eye-Tracking in Applied Linguistics and Second Language Research

    Science.gov (United States)

    Conklin, Kathy; Pellicer-Sánchez, Ana

    2016-01-01

    With eye-tracking technology the eye is thought to give researchers a window into the mind. Importantly, eye-tracking has significant advantages over traditional online processing measures: chiefly that it allows for more "natural" processing as it does not require a secondary task, and that it provides a very rich moment-to-moment data…

  12. Gaps in Current Knowledge and Priorities for Future Research in Dry Eye.

    Science.gov (United States)

    Saldanha, Ian J; Dickersin, Kay; Hutfless, Susan T; Akpek, Esen K

    2017-12-01

    Dry eye, a common yet underrecognized and evolving field, has few recommended treatment algorithms, mostly based on expert consensus rather than robust research evidence. There are high costs associated with managing dry eye and conducting research to identify effective and safe long-term treatments. To support evidence-based management of dry eye, our purpose was to identify and prioritize important clinical research questions for future clinical research. We translated recommendations from the American Academy of Ophthalmology's 2013 Preferred Practice Patterns for dry eye into answerable clinical research questions about treatment effectiveness. Clinicians around the world who manage patients with dry eye rated each question's importance from 0 (not important) to 10 (very important) using a 2-round online Delphi survey. We considered questions as "important" if ≥75% of respondents assigned a rating of 6 or more in round 2. We mapped the identified important clinical research questions to reliable systematic reviews published up to March 2016. Seventy-five clinicians from at least 21 countries completed both Delphi rounds. Among the 58 questions, 24 met our definition of "important": 9/24 and 7/24 addressed topical and systemic treatments, respectively. All 4 questions with the highest 25th percentiles addressed topical treatments. Although 6/24 "important" questions were associated with 4 existing reliable systematic reviews, none of these reviews came to a definitive conclusion about treatment effectiveness. We identified gaps pertaining to treatment options for dry eye. Future clinical research on the management of dry eye should strongly consider these prioritized questions.

  13. Practical Use of the Eye Camera in Pedagogical Research (Processing of Selected Data Using the Eye Tracking Method

    Directory of Open Access Journals (Sweden)

    Škrabánková Jana

    2016-06-01

    Full Text Available The paper deals with author’s pilot experiments using the eye tracking method for the primary school children examination. This method enables to gain a large amount of research data based on the tested people’s eye movements monitoring. In the paper, there are processed chosen research data of four gifted students’ examination in the context of their mathematical and logical intelligence.

  14. An optomechanical model eye for ophthalmological refractive studies.

    Science.gov (United States)

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  15. Different schematic eyes and their accuracy to the in vivo eye: a quantitative comparison study

    OpenAIRE

    Almeida, Marina Storani de; Carvalho, Luis Alberto

    2007-01-01

    Current ophthalmic technology allows the manipulation of eye components, such as anterior cornea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulat...

  16. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy Beth; Ellervik, Christina; Buch, Helena

    2016-01-01

    , Danish Rural Eye Study (DRES). All DRES participants received a comprehensive general health examination preceding their eye examination, including measurement of best-corrected visual acuity (BCVA) for each eye, bilateral 45° retinal fundus photographs and further ophthalmological examination where...... indicated. RESULTS: Overall, 3826 of 3843 participants (99.6%) had bilateral visual acuity measurements. The overall frequency of VI (BCVA eye) was 0.4% (95% confidence interval, CI, 0.2-0.7%; n = 15) among all DRES participants, 0.6% (95% CI 0.3-1.0%; n = 15) among participants...... >50 years and 3.7% (95% CI 2.1-6.5%; n = 11) in participants >80 years. The primary causes of VI in the better-seeing eye were age-related macular degeneration (AMD) in 46.7% (7/15) and cataract in 26.7% (4/15). A total of 43.3% (n = 115) of participants >80 years were pseudophakic in one or both eyes...

  17. Peripheral Retinal Changes Associated with Age-Related Macular Degeneration in the Age-Related Eye Disease Study 2: Age-Related Eye Disease Study 2 Report Number 12 by the Age-Related Eye Disease Study 2 Optos PEripheral RetinA (OPERA) Study Research Group.

    Science.gov (United States)

    Domalpally, Amitha; Clemons, Traci E; Danis, Ronald P; Sadda, SriniVas R; Cukras, Catherine A; Toth, Cynthia A; Friberg, Thomas R; Chew, Emily Y

    2017-04-01

    To compare rates of peripheral retinal changes in Age-Related Eye Disease Study 2 (AREDS2) participants with at least intermediate age-related macular degeneration (AMD) with control subjects without intermediate age-related changes (large drusen). Cross-sectional evaluation of clinic-based patients enrolled in AREDS2 and a prospective study. Participants from prospective studies. The 200° pseudocolor and fundus autofluorescence (FAF) images were captured on the Optos 200 Tx Ultrawide-field device (Optos, Dunfermline, Scotland) by centering on the fovea and then steering superiorly and inferiorly. The montaged images were graded at a reading center with the images divided into 3 zones (zone 1 [posterior pole], zone 2 [midperiphery], and zone 3 [far periphery]) to document the presence of peripheral lesions. Peripheral retinal lesions: drusen, hypopigmentary/hyperpigmentary changes, reticular pseudodrusen, senile reticular pigmentary changes, cobblestone degeneration, and FAF abnormalities. A total of 484 (951 eyes) AREDS2 participants with AMD (cases) and 89 (163 eyes) controls without AMD had gradable color and FAF images. In zones 2 and 3, neovascularization and geographic atrophy (GA) were present, ranging from 0.4% to 6% in eyes of cases, respectively, and GA was present in 1% of eyes of controls. Drusen were detected in 97%, 78%, and 64% of eyes of cases and 48%, 21%, and 9% of eyes of controls in zones 2 and 3 superior and 3 inferior, respectively (P < 0.001 for all). Peripheral reticular pseudodrusen were seen in 15%. Senile reticular pigmentary change was the predominant peripheral change seen in 48% of cases and 16% of controls in zone 2 (P < 0.001). Nonreticular pigment changes were less frequent in the periphery than in the posterior pole (46% vs. 76%) and negligible in controls. Peripheral retinal changes are more prevalent in eyes with AMD than in control eyes. Drusen are seen in a majority of eyes with AMD in both the mid and far periphery, whereas

  18. Enhancing Indigenous Health Promotion Research Through Two-Eyed Seeing: A Hermeneutic Relational Process.

    Science.gov (United States)

    Hovey, Richard B; Delormier, Treena; McComber, Alex M; Lévesque, Lucie; Martin, Debbie

    2017-07-01

    The intention of this article is to demonstrate how Indigenous and allied health promotion researchers learned to work together through a process of Two-Eyed Seeing. This process was first introduced as a philosophical hermeneutic research project on diabetes prevention within an Indigenous community in Quebec Canada. We, as a research team, became aware that hermeneutics and the principles of Haudenosaunee decision making were characteristic of Two-Eyed Seeing. This article describes our experiences while working with each other. Our learning from these interactions emphasized the relational aspects needed to ensure that we became a highly functional research team while working together and becoming Two-Eyed Seeing partners.

  19. An overview of how eye tracking is used in communication research

    NARCIS (Netherlands)

    Bol, N.; Boerman, S.C.; Romano Bergstrom, J.C.; Kruikemeier, S.; Antona, M.; Stephanidis, C.

    2016-01-01

    Eye tracking gives communication scholars the opportunity to move beyond self-reported measures by examining more precisely how much visual attention is paid to information. However, we lack insight into how eye-tracking data is used in communication research. This literature review provides an

  20. Christoph Scheiner's eye studies.

    Science.gov (United States)

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century.

  1. Tromsø eye study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Peto, Tunde; Lindekleiv, Haakon

    2013-01-01

    Purpose:  To determine the prevalence of visual impairment, retinopathy and macular oedema, and assess risk factors for retinopathy in persons with diabetes. Methods:  The present study included 514 participants with diabetes aged 46-87 years from the Tromsø Eye Study, a sub-study of the population......-based Tromsø Study in Norway. Visual acuity was measured using an auto-refractor. Retinal images from both eyes were graded for retinopathy and macular oedema. We collected data on risk factor exposure from self-report questionnaires, clinical examinations, laboratory measurements and case note reviews...

  2. The retina as a window to the brain-from eye research to CNS disorders.

    Science.gov (United States)

    London, Anat; Benhar, Inbal; Schwartz, Michal

    2013-01-01

    Philosophers defined the eye as a window to the soul long before scientists addressed this cliché to determine its scientific basis and clinical relevance. Anatomically and developmentally, the retina is known as an extension of the CNS; it consists of retinal ganglion cells, the axons of which form the optic nerve, whose fibres are, in effect, CNS axons. The eye has unique physical structures and a local array of surface molecules and cytokines, and is host to specialized immune responses similar to those in the brain and spinal cord. Several well-defined neurodegenerative conditions that affect the brain and spinal cord have manifestations in the eye, and ocular symptoms often precede conventional diagnosis of such CNS disorders. Furthermore, various eye-specific pathologies share characteristics of other CNS pathologies. In this Review, we summarize data that support examination of the eye as a noninvasive approach to the diagnosis of select CNS diseases, and the use of the eye as a valuable model to study the CNS. Translation of eye research to CNS disease, and deciphering the role of immune cells in these two systems, could improve our understanding and, potentially, the treatment of neurodegenerative disorders.

  3. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  4. Use of Cognitive and Metacognitive Strategies in Online Search: An Eye-Tracking Study

    Science.gov (United States)

    Zhou, Mingming; Ren, Jing

    2016-01-01

    This study used eye-tracking technology to track students' eye movements while searching information on the web. The research question guiding this study was "Do students with different search performance levels have different visual attention distributions while searching information online? If yes, what are the patterns for high and low…

  5. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    Science.gov (United States)

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  6. Post-destructive eye surgery, associated depression at Sekuru Kaguvi Hospital Eye Unit, Zimbabwe: Pilot Study

    Directory of Open Access Journals (Sweden)

    M. M. Kawome

    2013-12-01

    Full Text Available Destructive eye surgery is associated with more complications than just loss of visual functions of the eye and aesthetics. Currently there is very little published literature on post-destructive eye surgery associated depression. Zimbabwe has been experiencing a surge in the rate of destructive eye surgery done at the National Tertiary Eye Unit. This situation could be churning out lots of unrecognized depressed clients into the community who require assistance in one form or another. Objectives: To determine the prevalence of post-destructive eye surgery associated depression among patients attending Sekuru Kaguvi Hospital Eye Unit and assess if the current management protocol of patients undergoing destructive eye surgery at the Eye Unit addresses the problem adequately. Methods: A cross-sectional study of 28 randomly selected patients who had destructive eye surgeries at Sekuru Kaguvi Hospital was conducted over five months from 1st March 2012 to end of July 2012. A structured questionnaire containing 15 questions on the following items: gender, age, diagnosis, surgical procedure done, expectations before and after surgery, adequacy of counseling given and involvement of family was used to collect data. Nine questions to assess depression were adapted from the Patient Health Questionnaire (PHQ-9. Setting:  The study was conducted at SekuruKaguvi Hospital Eye Unit, Parirenyatwa Group of Hospitals in Harare. Results:  Twenty-eight patients who underwent destructive eye surgery during the study period were selected using systematic random sampling. The gender ratio was 1:1 and the mean age was 38.7 years with a range from 24 to 65 years. Fifty percent of the patients in the study had orbital exenteration while the rest had enucleation (14% and evisceration (36%. Twenty-eight percent of the study population had depression. Conclusion: Destructive eye surgery is frequently associated with depression and our current management protocol of

  7. Study on the transverse chromatic aberration of the individual eye model after LASIK refractive surgery

    Science.gov (United States)

    Zhang, Mei; Wang, Zhao-Qi; Wang, Yan; Zuo, Tong

    2010-10-01

    The aim of this research is to study the properties of the transverse chromatic aberration (TCA) after the LASIK refractive surgery based on the individual eye model involving the angle between visual axis and optical axis. According to the measurements of the corneal surfaces, the optical axis lengths and the wavefront aberrations, the individual eye models before and after LASIK refractive surgery are constructed for 15 eyes by using ZEMAX optic design software, while the angle between the visual axis and optical axis is calculated from the data of the anterior corneal surface. The constructed eye models are then used to investigate the variation of the TCA after the surgery. The statistical distributions of the magnitude of the foveal TCA for 15 eyes over the visible spectrum are provided. Finally, we investigate the influence of the TCA on the visual quality and compare the results with previous research. The TCA is an indispensable criterion to evaluate the performance of the refractive surgery. This research is very meaningful for the studies of not only foveal vision but also the peripheral vision.

  8. A Study on Hospital Admissions For Eye Trauma in Kashan, Iran.

    Science.gov (United States)

    Movahedinejad, Tayebeh; Adib-Hajbaghery, Mohsen; Zahedi, Mohammad Reza

    2016-05-01

    Eye trauma is among the most common reasons for referral to hospital emergency departments and ophthalmologists' offices. It also is a common cause of vision loss worldwide. However, few studies are available on the changes in the epidemiology of eye trauma in Iran in recent years. This study aimed to investigate the characteristics of hospital admissions for eye trauma in Kashan from August 2011 to February 2014. A cross-sectional study was carried out on the hospital records of all patients with eye trauma who were admitted to Kashan's Matini hospital between August 2011 and February 2014. Having an eye trauma and being hospitalized for at least one day was selected as the criteria for inclusion in the study. The data were then recorded on a checklist devised by the researcher. After entering the data into the SPSS software, descriptive statistics (i.e., percentage, frequency, mean, and standard deviation) were calculated for all variables. Chi-square, Fisher's exact test, and Mann-Whitney U test were used to analyze the data. In total, 200 patients with eye trauma had been hospitalized in Matini Hospital between August 2011 and February 2014. Of these patients, 86% were males, 40% were in the age range of 20-39 years, 68% lived in urban areas, and 21% of those in employment were manual and industrial workers. Approximately 38.5% of eye traumas had occurred in the work place; 72.5% of patients had penetrating injuries and 98% of cases were injured in one eye. More injuries occurred in the cornea (25.5%) than elsewhere in the eye, and 75.5% of patients were treated surgically. Among all variables, only the type of trauma (P = 0.009) and cause of trauma (P = 0.004) were significantly related to the patients' gender. Eye trauma was prevalent among males, young people, urban residents, and manual and industrial workers. As the eyes play a vital role in daily life, communication, and work activities, and eye health is so important for individuals to attain high

  9. Use of computerized tomography in the Multibrauch Research and Technology Complex ''Eye microsurgery''

    International Nuclear Information System (INIS)

    Fedorov, S.N.; Ivashina, A.I.; Anisimov, S.I.; Prokopenko, L.N.; Moskvichev, A.L.

    1989-01-01

    The paper is devoted to analysis of the results of computerized tomography (CT) in 1000 patients examined in te Multibranch Research and Technology Complex ''Eye Microsurgery''. The specific feature of CT in this institution is that 52% of all investigations of ophthalmological patients fall to the share of eyeball abnormality and 40% - to a study of the other parts of the organ of vision. CT indications are extended for low tension glaucoma, complicated high myopia, and for monitoring the position of microsurgical implants. The use of CT is such a highly specialized medical institution as the MRTC ''Eye Microsurgery'' is considered indispensable

  10. Nuclear fuel waste management program geotechnical studies of Eye-Dashwa Lakes research area rock properties

    International Nuclear Information System (INIS)

    Chernis, P.J.; Robertson, P.B.

    1992-05-01

    The Eye-Dashwa Lakes pluton near Atikokan Ontario has been used as a study area for the Canadian nuclear fuel waste management research program. The pluton consists predominately of granite. Fractures formed during cooling of the pluton were filled with a succession of different materials at different times. Measurements of a series of geophysical and geotechnical properties of rock samples are published here in this report, including especially microcrack and pore structures. An indication has been found that a larger proportion of the porosity of Whiteshell and Atikokan samples is contained in connecting pores, compared to other rocks. This may seem surprising in view of the finding that approximately 70% of the effective porosity of Atikokan samples is contained in pockets

  11. Research of Digital Interface Layout Design based on Eye-tracking

    Directory of Open Access Journals (Sweden)

    Shao Jiang

    2015-01-01

    Full Text Available The aim of this paper is to improve the low service efficiency and unsmooth human-computer interaction caused by currently irrational layouts of digital interfaces for complex systems. Also, three common layout structures for digital interfaces are to be presented and five layout types appropriate for multilevel digital interfaces are to be summarized. Based on the eye tracking technology, an assessment was conducted in advantages and disadvantages of different layout types through subjects’ search efficiency. Based on data and results, this study constructed a matching model which is appropriate for multilevel digital interface layout and verified the fact that the task element is a significant and important aspect of layout design. A scientific experimental model of research on digital interfaces for complex systems is provided. Both data and conclusions of the eye movement experiment provide a reference for layout designs of interfaces for complex systems with different task characteristics.

  12. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Ellervik, Christina

    2015-01-01

    and older from a Danish rural municipality received a complete general health examination and an ophthalmological interview and examination. This study included a comprehensive ophthalmologic interview, measurement of best corrected visual acuity (BCVA) in each eye, Hirschberg's test for strabismus and two...... 45-degree retinal fundus photographs of each eye. A complete ophthalmologic examination was performed when indicated. RESULTS: The prevalence of monocular visual impairment (MVI) was 4.26% (95% CI, 3.66-4.95, n = 163). Amblyopia was the most common cause, accounting for 33%. The prevalence...

  13. How visual search relates to visual diagnostic performance: a narrative systematic review of eye-tracking research in radiology.

    Science.gov (United States)

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J

    2017-08-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye

  14. NMR spectroscopy applied to the eye: Drugs and metabolic studies

    Energy Technology Data Exchange (ETDEWEB)

    Saether, Oddbjoern

    2005-07-01

    NMR spectroscopy has been extensively applied in biomedical research during the last decades. It has proved to be an analytical tool of great value. From being mainly used in chemistry, technological developments have expanded the application of NMR spectroscopy to a great wealth of disciplines. With this method, biochemical information can be obtained by analysing tissue extracts. Moreover, NMR spectroscopy is increasingly employed for pharmacokinetic studies and analysis of biofluids. Technological progress has provided increased sensitivity and resolution in the spectra, which enable even more of the complexity of biological samples to be elucidated. With the implementation of high-resolution magic angle spinning (HR-MAS) NMR spectroscopy in biomedicine, intact tissue samples or biopsies can be investigated. Thus, NMR spectroscopy has an ever-increasing impact in metabolic screening of human samples and in animal models, and methods are also increasingly realised in vivo. The present work, NMR spectroscopy applied to eye research, consists of two main parts. Firstly, the feasibility to monitor fluorinated ophthalmic drugs directly in the eye was assessed. Secondly, HR-MAS H1 NMR spectroscopy was applied for metabolic profiling of the anterior eye segment, specifically to analyse metabolic changes in intact corneal and lenticular samples after cataractogenic insults. This work included metabonomics with the application of pattern recognition methods to analyse HR-MAS spectra of eye tissues. Optimisation strategies were explored for F19 NMR detection of fluorinated drugs in a phantom eye. S/N gains in F19 NMR spectroscopy were achieved by implementing time-share H1 decoupling at 2.35 T. The method is advantageous for compounds displaying broad spectral coupling patterns, though detection of drugs at concentrations encountered in the anterior eye segment after topical application was not feasible. Higher magnetic fields and technological improvements could enable

  15. NMR spectroscopy applied to the eye: Drugs and metabolic studies

    International Nuclear Information System (INIS)

    Saether, Oddbjoern

    2005-01-01

    NMR spectroscopy has been extensively applied in biomedical research during the last decades. It has proved to be an analytical tool of great value. From being mainly used in chemistry, technological developments have expanded the application of NMR spectroscopy to a great wealth of disciplines. With this method, biochemical information can be obtained by analysing tissue extracts. Moreover, NMR spectroscopy is increasingly employed for pharmacokinetic studies and analysis of biofluids. Technological progress has provided increased sensitivity and resolution in the spectra, which enable even more of the complexity of biological samples to be elucidated. With the implementation of high-resolution magic angle spinning (HR-MAS) NMR spectroscopy in biomedicine, intact tissue samples or biopsies can be investigated. Thus, NMR spectroscopy has an ever-increasing impact in metabolic screening of human samples and in animal models, and methods are also increasingly realised in vivo. The present work, NMR spectroscopy applied to eye research, consists of two main parts. Firstly, the feasibility to monitor fluorinated ophthalmic drugs directly in the eye was assessed. Secondly, HR-MAS H1 NMR spectroscopy was applied for metabolic profiling of the anterior eye segment, specifically to analyse metabolic changes in intact corneal and lenticular samples after cataractogenic insults. This work included metabonomics with the application of pattern recognition methods to analyse HR-MAS spectra of eye tissues. Optimisation strategies were explored for F19 NMR detection of fluorinated drugs in a phantom eye. S/N gains in F19 NMR spectroscopy were achieved by implementing time-share H1 decoupling at 2.35 T. The method is advantageous for compounds displaying broad spectral coupling patterns, though detection of drugs at concentrations encountered in the anterior eye segment after topical application was not feasible. Higher magnetic fields and technological improvements could enable

  16. STUDY OF PREVALENCE OF DRY EYE IN DIABETES

    Directory of Open Access Journals (Sweden)

    Vivek Mahadev Sahasrabudhe

    2017-06-01

    Full Text Available BACKGROUND Diabetes causes blindness in 20-74 year old persons. Blindness in diabetic patients may due to cataract or retinopathy. Dry eye is one of the ocular surface problem increasingly observed in diabetic patients. This study was performed to assess the prevalence of dry eye syndrome in type 2 diabetic patients and their contributing factors. MATERIALS AND METHODS A cross-sectional study was done between April 2016 to September 2016. 70 patients of type 2 diabetes diagnosed at Dr. Shankarrao Chavan Government Hospital, Nanded, were included in this study. Patients were assessed by questionnaire about other diseases and drugs. Dry eye syndrome was assessed with Tear Breakup Time (TBUT, Schirmer's test, lissamine green staining apart from routine ophthalmic examination. RESULTS Out of 60 patients, 32 (53% suffer from dry eye syndrome. CONCLUSION Diabetes and dry eyes appear to have a common association. Further studies need to be undertaken to establish an aetiologic relationship. As routine dilated fundus examination is an integral part of evaluation of diabetic patients in ophthalmic clinics, examination for dry eye should also be an integral part of the assessment of diabetic eye disease.

  17. The research of the style of angel lobster eye x-ray optical system

    Science.gov (United States)

    Cheng, HuaQi; Liu, YuJiao; Zhang, ShaoWei; Hou, LinBao; Li, XingLong

    2018-01-01

    This paper has developed the theory research of wide field Angel lobster eye X-ray optical system based on the principle of entirely incidence. Combine the configuration characteristic of lobster eye, recommend the conclusion of beam of light focus on the half of radius whether point or parallel light. Designed the microchannel through the principle of real ray trace and got the relationship among different parameters about it using numerical value emulation. Got pixels and illumination pictures validated the wide field focus characteristic of Angel lobster eye by simulating the optical system.

  18. In the eye of the beholder: eye contact increases resistance to persuasion.

    Science.gov (United States)

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  19. [Research progress of conscious pain and neurosensory abnormalities in dry eye disease].

    Science.gov (United States)

    Lin, X; Liu, Z L; Wu, J L; Liu, Z G

    2018-02-11

    Dry eye is one of the most common ocular problems in ophthalmology clinic. With the change of social environment and people's life style, the prevalence of dry eye disease is increasing. Currently, the diagnosis criteria for dry eye is controversial, diagnosis of dry eye mainly rely on the comprehensive assessment of symptoms and the presence of associated ocular surface signs. However, previous studies have shown a poor correlation between dry eye symptoms and objective clinical signs in patients. Recent studies have found that neuropathic pain plays an important role in the occurrence of discordance between symptoms and signs in dry eye disease. The purpose of this paper is to present the conception of pain, the distribution and function of sensory nerves in ocular surface, the prevalence and mechanism of neuropathic pain and analgesic treatment in dry eye disease. (Chin J Ophthalmol, 2018, 54: 144-148) .

  20. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  1. On Biometrics With Eye Movements.

    Science.gov (United States)

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  2. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    Directory of Open Access Journals (Sweden)

    J. J. Gu

    2006-01-01

    Full Text Available Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the control system to drive the artificial eye to move with the natural eye. The second generation model removes the impractical usage of the eye glass frame and uses the human brain EOG (electro-ocular-graph signal picked up by electrodes placed on the sides of a person's temple to carry out the same eye movement detection and control tasks as mentioned above. Theoretical issues on sensor failure detection and recovery, and signal processing techniques used in sensor data fusion, are studied using statistical methods and artificial neural network based techniques. In addition, practical control system design and implementation using micro-controllers are studied and implemented to carry out the natural eye movement detection and artificial robotic eye control tasks. Simulation and experimental studies are performed, and the results are included to demonstrate the effectiveness of the research project reported in this paper.

  3. Expertise differences in air traffic control: An eye-tracking study

    NARCIS (Netherlands)

    Van Meeuwen, Ludo; Jarodzka, Halszka; Brand-Gruwel, Saskia; Kirschner, Paul A.; De Bock, Jeano; Van Merriënboer, Jeroen

    2012-01-01

    Van Meeuwen, L. W., Jarodzka, H., Brand-Gruwel, S., Kirschner, P. A., De Bock, J. J. P. R., & Van Merriënboer, J. J. G. (2012, April). Expertise differences in air traffic control: An eye-tracking study. Paper presented at the American Educational Research Association Annual Meeting 2012, Vancouver,

  4. Eye-Tracking Technology and the Dynamics of Natural Gaze Behavior in Sports: A Systematic Review of 40 Years of Research.

    Science.gov (United States)

    Kredel, Ralf; Vater, Christian; Klostermann, André; Hossner, Ernst-Joachim

    2017-01-01

    Reviewing 60 studies on natural gaze behavior in sports, it becomes clear that, over the last 40 years, the use of eye-tracking devices has considerably increased. Specifically, this review reveals the large variance of methods applied, analyses performed, and measures derived within the field. The results of sub-sample analyses suggest that sports-related eye-tracking research strives, on the one hand, for ecologically valid test settings (i.e., viewing conditions and response modes), while on the other, for experimental control along with high measurement accuracy (i.e., controlled test conditions with high-frequency eye-trackers linked to algorithmic analyses). To meet both demands, some promising compromises of methodological solutions have been proposed-in particular, the integration of robust mobile eye-trackers in motion-capture systems. However, as the fundamental trade-off between laboratory and field research cannot be solved by technological means, researchers need to carefully weigh the arguments for one or the other approach by accounting for the respective consequences. Nevertheless, for future research on dynamic gaze behavior in sports, further development of the current mobile eye-tracking methodology seems highly advisable to allow for the acquisition and algorithmic analyses of larger amounts of gaze-data and further, to increase the explanatory power of the derived results.

  5. Eye-Tracking Technology and the Dynamics of Natural Gaze Behavior in Sports: A Systematic Review of 40 Years of Research

    Directory of Open Access Journals (Sweden)

    Ralf Kredel

    2017-10-01

    Full Text Available Reviewing 60 studies on natural gaze behavior in sports, it becomes clear that, over the last 40 years, the use of eye-tracking devices has considerably increased. Specifically, this review reveals the large variance of methods applied, analyses performed, and measures derived within the field. The results of sub-sample analyses suggest that sports-related eye-tracking research strives, on the one hand, for ecologically valid test settings (i.e., viewing conditions and response modes, while on the other, for experimental control along with high measurement accuracy (i.e., controlled test conditions with high-frequency eye-trackers linked to algorithmic analyses. To meet both demands, some promising compromises of methodological solutions have been proposed—in particular, the integration of robust mobile eye-trackers in motion-capture systems. However, as the fundamental trade-off between laboratory and field research cannot be solved by technological means, researchers need to carefully weigh the arguments for one or the other approach by accounting for the respective consequences. Nevertheless, for future research on dynamic gaze behavior in sports, further development of the current mobile eye-tracking methodology seems highly advisable to allow for the acquisition and algorithmic analyses of larger amounts of gaze-data and further, to increase the explanatory power of the derived results.

  6. EDITORIAL: Special issue containing contributions from the Sixth Biennial Research Congress of The Eye and the Chip Special issue containing contributions from the Sixth Biennial Research Congress of The Eye and the Chip

    Science.gov (United States)

    Hessburg, Philip C.

    2011-06-01

    Once again Journal of Neural Engineering is devoting an issue to the field of visual neuro-prosthetics. These papers were presented at the Sixth Biennial Research Congress of The Eye and the ChipA 13 DVD set of all presentations at The Eye and the Chip 2010 is available from Carolyn Barth PhD, Detroit Institute of Ophthalmology, 15415 E Jefferson, Grosse Pointe Park MI 48230, USA, 313.824.4710, clbarth@dioeyes.org, held in Detroit in September 2010. In the last decade this field has metamorphosed from 'in all probability a foolish and impractical dream' to a device approved for implantation in Europe and pending approval in the United States, and from a handful of serious efforts to several dozen on every continent save for Antartica. A recent comprehensive volume, Visual Prosthetics [1], edited by Gislin Dagnelie of Johns Hopkins University School of Medicine, focuses closely on this subject and is a tremendous addition to the literature. In his preface Dr Dagnelie notes as follows. 'In the year 2000, the Detroit Institute of Ophthalmology had the inspiration to foster a new collaboration among visual prosthesis researchers, clinicians, and workers in low vision rehabilitation by creating and sponsoring a series of biennial meetings called 'The Eye and the Chip'. Successful beyond expectations, these meetings have become the premier gathering place for researchers from all parts of the world and from very different backgrounds. Invited speakers are scientists who are advancing the field, yet the scale and atmosphere allow all researchers, patients, and the media to come and be updated about progress over the past two years. More perhaps than at other scientific meetings, where investigators tend to gather within disciplines, participants at The Eye and the Chip are challenged to be open-minded, learn about and critique each other's work, and return home with fresh ideas for interdisciplinary approaches. The interdisciplinary character of this book reflects that

  7. SIDRE: Symptomatic Improvement of Dry Eye Study

    Directory of Open Access Journals (Sweden)

    De Paz CJ

    2017-03-01

    Full Text Available Clarissa J De Paz, Agustin L Gonzalez, Chi Ngo Eye & Vision, Richardson, TX, USA Purpose: The aim of this study was to evaluate the effectiveness of lifitegrast 5% ophthalmic solution in reducing the symptoms of eye dryness using Ocular Surface Disease Index (OSDI questionnaire. Methods: A single-center study was undertaken to evaluate the clinical outcomes. Fourteen subjects (12 female and 2 male with symptoms of dry eye and a positive history of recent use of artificial tears were included in the study. OSDI questionnaire scores on the severity of symptoms, visual functionality, and quality of life related to the condition were recorded pre- and post-therapy. Subsequently, score data were analyzed for statistical significance. Results: The mean age of the 14 subjects was 44.86 (standard deviation [SD] ±3.08 years, with a range of 23–62 years. Mean duration of the evaluation was 28.79 days with a range of 25–34 days. Baseline OSDI mean score was 49.40 (SD ±1.28, and post-therapy mean score was 42.26 (SD ±0.99. Data analysis revealed that the scores were statistically significantly improved post-lifitegrast therapy in comparison to baseline (p=0.00041. Conclusion: Lifitegrast 5% ophthalmic solution may be a beneficial therapeutic option in the management of symptoms associated with dry eye disease. Keywords: dry eye disease, ocular surface disease, dry eye treatment, lifitegrast

  8. Telemedicine and Diabetic Eye Disease

    Centers for Disease Control (CDC) Podcasts

    We know that the leading cause of blindness in working-age adults is eye disease related to poorly managed diabetes. In a prevention research study, telemedicine was shown to increase the number of people getting screened for diabetic eye disease.

  9. Which Eye Tracker is Right for Your Research Performance Evaluation of Several Cost Variant Eye Trackers

    Science.gov (United States)

    2016-09-19

    utilized to study a diverse number of topics such as the patterns of fixations and saccades while reading text (e.g., Rayner, 1998), the workload of...of their accessibility to our laboratory and because they represent a diverse set of relative price points, from low (Eye Tribe Tracker, Tobii EyeX...see Figure 1 for the layout of those systems). At both workstations, task stimuli were presented to observers on 48.26 cm Samsung SyncMaster 940Bx

  10. Eye movements and attention in reading, scene perception, and visual search.

    Science.gov (United States)

    Rayner, Keith

    2009-08-01

    Eye movements are now widely used to investigate cognitive processes during reading, scene perception, and visual search. In this article, research on the following topics is reviewed with respect to reading: (a) the perceptual span (or span of effective vision), (b) preview benefit, (c) eye movement control, and (d) models of eye movements. Related issues with respect to eye movements during scene perception and visual search are also reviewed. It is argued that research on eye movements during reading has been somewhat advanced over research on eye movements in scene perception and visual search and that some of the paradigms developed to study reading should be more widely adopted in the study of scene perception and visual search. Research dealing with "real-world" tasks and research utilizing the visual-world paradigm are also briefly discussed.

  11. A Clinical Study of Subtype-based Prevalence of Dry Eye.

    Science.gov (United States)

    Rege, Aditya; Kulkarni, Varsha; Puthran, Neelam; Khandgave, Tejaswini

    2013-10-01

    Dry Eye is a multifactorial disease of the tearfilm and the ocular surface which may be due to reduced tear production or excessive tear evaporation resulting in discomfort, visual disturbance, and tear film instability with a potential damage to the ocular surface. Various population-based studies have been done to find out the prevalence and the magnitude of the problem. Women Health Study reported prevalence of 7.8% after screening 36995 subjects above 49 years by interview. The prevalence reported by Blue Mountain Study was 15.3% .The Beaver Dam Study and Shiphai Eye studies are other studies reporting prevalence of 14.5% and 33.7% respectively. McMonnies questionnaire is a widely used screening instrument for Dry-Eye syndromes with sensitivity reportedly varying between 87% and 98% and specificity between 87% and 97%. Prevalence studies use McMonnie's questionnaire for screening individuals for Dry Eye, whereafter tests like Schirmer's test, Tear Film Break Up Time test, Rose Bengal test, Lissamine Green test and Meibomian Gland Dysfunction test are useful for further evaluation. While these tests help to differentiate the subtypes of Dry Eye such as Lipid Anomaly Dry Eye, Aqueous Tear Deficiency and Mucin Layer Deficiency, however, their sensitivity and specificity has not been widely studied. Additionally, very few studies have reported the prevalence of the various subtypes of Dry Eye. To determine the subtype-based prevalence of Dry Eye, to study the specificity and sensitivity of clinical tests for Dry Eye and to correlate McMonnies questionnaire with Dry Eye tests results. A prospective, cross-sectional, observational study, duly approved by the Institutional Ethics Committee, was conducted from October 2010 to April 2012. A total of 4750 subjects above 18 yrs of age were screened by the McMonnies questionnaire. Respondents having a score greater than 14.5 were subjected to clinical Dry Eye tests. The data obtained was analyzed using chi-square test. p

  12. WiseEye: Next Generation Expandable and Programmable Camera Trap Platform for Wildlife Research.

    Directory of Open Access Journals (Sweden)

    Sajid Nazir

    Full Text Available The widespread availability of relatively cheap, reliable and easy to use digital camera traps has led to their extensive use for wildlife research, monitoring and public outreach. Users of these units are, however, often frustrated by the limited options for controlling camera functions, the generation of large numbers of images, and the lack of flexibility to suit different research environments and questions. We describe the development of a user-customisable open source camera trap platform named 'WiseEye', designed to provide flexible camera trap technology for wildlife researchers. The novel platform is based on a Raspberry Pi single-board computer and compatible peripherals that allow the user to control its functions and performance. We introduce the concept of confirmatory sensing, in which the Passive Infrared triggering is confirmed through other modalities (i.e. radar, pixel change to reduce the occurrence of false positives images. This concept, together with user-definable metadata, aided identification of spurious images and greatly reduced post-collection processing time. When tested against a commercial camera trap, WiseEye was found to reduce the incidence of false positive images and false negatives across a range of test conditions. WiseEye represents a step-change in camera trap functionality, greatly increasing the value of this technology for wildlife research and conservation management.

  13. Tracking the Mind's Eye: A New Technology for Researching Twenty-First-Century Writing and Reading Processes

    Science.gov (United States)

    Anson, Chris M.; Schwegler, Robert A.

    2012-01-01

    This article describes the nature of eye-tracking technology and its use in the study of discourse processes, particularly reading. It then suggests several areas of research in composition studies, especially at the intersection of writing, reading, and digital media, that can benefit from the use of this technology. (Contains 2 figures.)

  14. Eye tracking and the translation process

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2014-01-01

    Eye tracking has become increasingly popular as a quantitative research method in translation research. This paper discusses some of the major methodological issues involved in the use of eye tracking in translation research. It focuses specifically on challenges in the analysis and interpretation...... of eye-tracking data as reflections of cognitive processes during translation. Four types of methodological issues are discussed in the paper. The first part discusses the preparatory steps that precede the actual recording of eye-tracking data. The second part examines critically the general assumptions...... linking eye movements to cognitive processing in the context of translation research. The third part of the paper discusses two popular eye-tracking measures often used in translation research, fixations and pupil size, while the fourth part proposes a method to evaluate the quality of eye-tracking data....

  15. Dosimetric study of the 15 mm ROPES eye plaque

    International Nuclear Information System (INIS)

    Granero, D.; Perez-Calatayud, J.; Ballester, F.; Casal, E.; Frutos, J.M. de

    2004-01-01

    The main aim of this paper is to make a study of dose-rate distributions obtained around the 15 mm, radiation oncology physics and engineering services, Australia (ROPES) eye plaque loaded with 125 I model 6711 radioactive seeds. In this study, we have carried out a comparison of the dose-rate distributions obtained by the algorithm used by the Plaque Simulator (PS) (BEBIG GmbH, Berlin, Germany) treatment planning system with those obtained by means of the Monte Carlo method for the ROPES eye plaque. A simple method to obtain the dose-rate distributions in a treatment planning system via the superposition of the dose-rate distributions of a seed placed in the eye plaque has been developed. The method uses eye plaque located in a simplified geometry of the head anatomy and distributions obtained by means of the Monte Carlo code GEANT4. The favorable results obtained in the development of this method suggest that it could be implemented on a treatment planning system to improve dose-rate calculations. We have also found that the dose-rate falls sharply along the eye and that outside the eye the dose-rate is very low. Furthermore, the lack of backscatter photons from the air located outside the eye-head phantom produces a dose reduction negligible for distances from the eye-plaque r<1 cm but reaches up to 20% near the air-eye interface. Results showed that the treatment planning system lacks accuracy around the border of the eye (in the sclera and the surrounding area) due to the simplicity of the algorithm used. The BEBIG treatment planning system uses a global attenuation factor that takes into account the effect of the eye plaque seed carrier and the lack of backscatter photons caused by the metallic cover, which in the case of a ROPES eye plaque has a default value of T=1 (no correction). In the present study, a global attenuation factor T=0.96 and an air-interface correction factor which improve on treatment planning system calculations were obtained

  16. The specificity of attentional biases by type of gambling: An eye-tracking study.

    Directory of Open Access Journals (Sweden)

    Daniel S McGrath

    Full Text Available A growing body of research indicates that gamblers develop an attentional bias for gambling-related stimuli. Compared to research on substance use, however, few studies have examined attentional biases in gamblers using eye-gaze tracking, which has many advantages over other measures of attention. In addition, previous studies of attentional biases in gamblers have not directly matched type of gambler with personally-relevant gambling cues. The present study investigated the specificity of attentional biases for individual types of gambling using an eye-gaze tracking paradigm. Three groups of participants (poker players, video lottery terminal/slot machine players, and non-gambling controls took part in one test session in which they viewed 25 sets of four images (poker, VLTs/slot machines, bingo, and board games. Participants' eye fixations were recorded throughout each 8-second presentation of the four images. The results indicated that, as predicted, the two gambling groups preferentially attended to their primary form of gambling, whereas control participants attended to board games more than gambling images. The findings have clinical implications for the treatment of individuals with gambling disorder. Understanding the importance of personally-salient gambling cues will inform the development of effective attentional bias modification treatments for problem gamblers.

  17. The specificity of attentional biases by type of gambling: An eye-tracking study.

    Science.gov (United States)

    McGrath, Daniel S; Meitner, Amadeus; Sears, Christopher R

    2018-01-01

    A growing body of research indicates that gamblers develop an attentional bias for gambling-related stimuli. Compared to research on substance use, however, few studies have examined attentional biases in gamblers using eye-gaze tracking, which has many advantages over other measures of attention. In addition, previous studies of attentional biases in gamblers have not directly matched type of gambler with personally-relevant gambling cues. The present study investigated the specificity of attentional biases for individual types of gambling using an eye-gaze tracking paradigm. Three groups of participants (poker players, video lottery terminal/slot machine players, and non-gambling controls) took part in one test session in which they viewed 25 sets of four images (poker, VLTs/slot machines, bingo, and board games). Participants' eye fixations were recorded throughout each 8-second presentation of the four images. The results indicated that, as predicted, the two gambling groups preferentially attended to their primary form of gambling, whereas control participants attended to board games more than gambling images. The findings have clinical implications for the treatment of individuals with gambling disorder. Understanding the importance of personally-salient gambling cues will inform the development of effective attentional bias modification treatments for problem gamblers.

  18. Eye-Tracking Study of Complexity in Gas Law Problems

    Science.gov (United States)

    Tang, Hui; Pienta, Norbert

    2012-01-01

    This study, part of a series investigating students' use of online tools to assess problem solving, uses eye-tracking hardware and software to explore the effect of problem difficulty and cognitive processes when students solve gas law word problems. Eye movements are indices of cognition; eye-tracking data typically include the location,…

  19. The specificity of attentional biases by type of gambling: An eye-tracking study

    OpenAIRE

    McGrath, Daniel S.; Meitner, Amadeus; Sears, Christopher R.

    2018-01-01

    A growing body of research indicates that gamblers develop an attentional bias for gambling-related stimuli. Compared to research on substance use, however, few studies have examined attentional biases in gamblers using eye-gaze tracking, which has many advantages over other measures of attention. In addition, previous studies of attentional biases in gamblers have not directly matched type of gambler with personally-relevant gambling cues. The present study investigated the specificity of at...

  20. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients.

    Science.gov (United States)

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40-69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008-2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months' supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies.

  1. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  2. A Novel Combination Therapy for Patients With Dry Eye Disease: A Pilot Study.

    Science.gov (United States)

    Smith, Will; McMahon, David; Nymark, Maria

    2018-05-01

    Context • Approximately 25% of the US population suffers from dry eyes or some abnormality of the exposed ocular surface. Investigation of effective modalities for their management is needed. Objective • The study intended to examine the efficacy of a proprietary, daily, Dry Eye Protocol consisting of daily use of a moist, heated, ocular compress and intake of an omega-3 dietary supplement in treatment of ocular surface disease. Design • The research team designed a 4-wk, clinically based, open-label, multicenter cohort study. Setting • The study took place at 6 private eye care practices throughout the United States: Beverly Hills, CA, USA; San Diego, CA, USA; Sunnyvale, CA, USA; Park City, UT, USA; Tarpon Spring, FL, USA; and Kennewick, WA, USA. Participants • Participants were adults between 18 and 75 y of age who had established ocular surface disease based on clinical findings and the results of testing using the ocular surface disease index (OSDI). Intervention • For period of 30 d, participants used a combined daily protocol that included (1) application of a moist, heated, eye compress and (2) a nutritional therapy via an omega-3 supplement in an oral triglyceride form. Outcome Measures • Measures included the OSDI and a test of tear break-up time (TBUT). Results • Of the original 35 participants, 33 completed the 4-wk protocol. The participants using the proprietary Dry Eye Protocol showed significant improvements from baseline, demonstrated by a 49% decrease in OSDI scores (P = .0015); and 46% of participants reported becoming asymptomatic of dry eye symptoms. A significant improvement was also observed in TBUT, increasing from 3.0 to 5.4 s. Conclusions • Daily use of the proprietary Dry Eye Protocol that included a high dosage of triglyceride omega-3 and use of a moist, heated, compress daily showed significant improvement for participants in OSDI and TBUT and should be considered to be a first-line therapy for patients with dry eye

  3. [Research update of effectiveness and mechanism of essential fatty acids in treating dry eye].

    Science.gov (United States)

    Liu, Y; Liang, Q F

    2017-03-11

    Topical anti-inflammatory therapy has become the significant way of treating dry eye so far. However, as the long-term use of routine anti-inflammatory medications are restricted from their side effects, it is inevitable to explore safer and more effective alternatives. Essential fatty acids have proven to be anti-inflammatory systemically, which makes it possible to treat dry eye. Clinical trials have demonstrated that supplementation with either ω-3 or ω-6 essential fatty acids or both has multifactorial efficacies including improvement of subjective symptoms, alleviation of inflammation of ocular surface and eyelid margin, prolongation of tear break-up time and increase of tear flow secretion. Besides anti-inflammation effects, several basic researches have revealed that other mechanisms of essential fatty acids treating dry eye might lie in the corneal epithelial healing and tear secretion promotion. This review puts emphasis on the effectiveness, feasibility and mechanism of treating dry eye with essential fatty acids. (Chin J Ophthalmol, 2017, 53: 225-229) .

  4. Yarbus, Eye Movements, and Vision

    Directory of Open Access Journals (Sweden)

    Benjamin W Tatler

    2010-04-01

    Full Text Available The impact of Yarbus's research on eye movements was enormous following the translation of his book Eye Movements and Vision into English in 1967. In stark contrast, the published material in English concerning his life is scant. We provide a brief biography of Yarbus and assess his impact on contemporary approaches to research on eye movements. While early interest in his work focused on his study of stabilised retinal images, more recently this has been replaced with interest in his work on the cognitive influences on scanning patterns. We extended his experiment on the effect of instructions on viewing a picture using a portrait of Yarbus rather than a painting. The results obtained broadly supported those found by Yarbus.

  5. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    Directory of Open Access Journals (Sweden)

    Ping Xie

    Full Text Available To construct a life-sized eye model using the three-dimensional (3D printing technology for fundus viewing study of the viewing system.We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs. Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D printing. Together with the main printed structure, polymethyl methacrylate(PMMA aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy.In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value.The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  6. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    Science.gov (United States)

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  7. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    Science.gov (United States)

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Background Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Methods Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. Results The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40–69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008–2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months’ supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Conclusion Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies. PMID:24179335

  8. The National Basketball Association eye injury study.

    Science.gov (United States)

    Zagelbaum, B M; Starkey, C; Hersh, P S; Donnenfeld, E D; Perry, H D; Jeffers, J B

    1995-06-01

    To investigate the epidemiology of eye injuries sustained by professional basketball players in the National Basketball Association (NBA). A prospective study involving all NBA athletes who sustained eye injuries between February 1, 1992, and June 20, 1993, was conducted. Twenty-seven NBA team athletic trainers, physicians, and ophthalmologists were provided data forms to complete for any player examined for an eye injury. Practice and game exposures during the preseason, regular season, playoffs, and championships were included. Of the 1092 injuries sustained by NBA players during the 17-month period, 59 (5.4%) involved the eye and adnexa. Eighteen (30.5%) of the injuries occurred while the player was in the act of rebounding, and 16 (27.1%) while the player was on offense. The most common diagnoses included 30 abrasions or lacerations to the eyelid (50.9%), 17 contusions (edema and/or ecchymosis) to the eyelid or periorbital region (28.8%), and seven corneal abrasions (11.9%). There were three orbital fractures (5.1%). Most injuries were caused by fingers (35.6%) or elbows (28.8%). Nine players (15.3%) missed subsequent games because of their injury. Fifty-seven players (96.6%) were not wearing protective eyewear at the time of injury. The incidence of eye injuries in NBA players during the 17-month period was 1.44 per 1000 game exposures. Frequent physical contact in professional basketball players leaves them at great risk for sustaining eye injuries. To prevent these injuries, protective eyewear is recommended.

  9. Molecular Genetic Studies of Some Eye Diseases Affecting the ...

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Molecular Genetic Studies of Some Eye Diseases Affecting the Indian Population. Single gene disorders. Complex eye diseases. Genotype-phenotype correlation. Molecular diagnostics.

  10. A Multi-Center Diabetes Eye Screening Study in Community Settings: Study Design and Methodology.

    Science.gov (United States)

    Murchison, Ann P; Friedman, David S; Gower, Emily W; Haller, Julia A; Lam, Byron L; Lee, David J; McGwin, Gerald; Owsley, Cynthia; Saaddine, Jinan; Insight Study Group

    2016-01-01

    Diabetes is the leading cause of new cases of blindness among adults aged 20-74 years within the United States. The Innovative Network for Sight Research group (INSIGHT) designed the Diabetic Eye Screening Study (DESS) to examine the feasibility and short-term effectiveness of non-mydriatic diabetic retinopathy (DR) screening for adults with diabetes in community-based settings. Study enrollment began in December 2011 at four sites: an internal medicine clinic at a county hospital in Birmingham, Alabama; a Federally-qualified community healthcare center in Miami-Dade County, Florida; a university-affiliated outpatient pharmacy in Philadelphia, Pennsylvania; and a medical home in Winston-Salem, North Carolina. People 18 years or older with previously diagnosed diabetes were offered free DR screening using non-mydriatic retinal photography that was preceded by a brief questionnaire addressing demographic information and previous eye care use. Visual acuity was also measured for each eye. Images were evaluated at a telemedicine reading center by trained evaluators using the National Health System DR grading classification. Participants and their physicians were sent screening report results and telephoned for a follow-up survey 3 months post-screening to determine whether participants had sought follow-up comprehensive eye care and their experiences with the screening process. Target enrollment at each site was a minimum of 500 persons. Three of the four sites met this enrollment goal. The INSIGHT/DESS is intended to establish the feasibility and short-term effectiveness of DR screening using non-mydriatic retinal photography in persons with diabetes who seek services in community-based clinic and pharmacy settings.

  11. How to Research People's First Impressions of Websites? Eye-Tracking as a Usability Inspection Method and Online Focus Group Research

    Science.gov (United States)

    Herendy, Csilla

    The visual surface of the Hungarian governmental portal - magyarorszag.hu - was inspected in 2007 with two different inspection methods: Eye tacking research and Online focus group research. Both methods help to understand and to chart not only the usability of different websites but also the affective imp ressions associated with the websites. In this study, an Experimental and a Control-group were tested to assess the usability of the site and the emotional re actions to it. The results reveal that the Hungarian government website is too complicated, dull and difficult to apprehend at a glance.

  12. Ecological Validity in Eye-Tracking: An Empirical Study

    Science.gov (United States)

    Spinner, Patti; Gass, Susan M.; Behney, Jennifer

    2013-01-01

    Eye-trackers are becoming increasingly widespread as a tool to investigate second language (L2) acquisition. Unfortunately, clear standards for methodology--including font size, font type, and placement of interest areas--are not yet available. Although many researchers stress the need for ecological validity--that is, the simulation of natural…

  13. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    Directory of Open Access Journals (Sweden)

    Stonecipher KG

    2013-10-01

    Full Text Available Karl G Stonecipher,1 Jenny Chia,2 Ahunna Onyenwenyi,2 Linda Villanueva,2 David A Hollander2 1TLC Laser Eye Centers, Greensboro, NC, 2Allergan, Inc., Irvine, CA, USA Background: Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis® use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Methods: Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. Results: The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40-69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008–2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months’ supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Conclusion: Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies. Keywords: corticosteroids, cyclosporine, dry eye syndromes

  14. Retinal vessel caliber and myopic retinopathy: the blue mountains eye study.

    Science.gov (United States)

    Li, Haitao; Mitchell, Paul; Rochtchina, Elena; Burlutsky, George; Wong, Tien Y; Wang, Jie Jin

    2011-12-01

    To evaluate changes in the retinal vasculature in eyes with myopic retinopathy. Population-based, cross-sectional study. Emmetropic and myopic participants from the Blue Mountains Eye Study baseline survey were included in this study. Myopia was defined as a refractive error of less than -1.00 diopter. Myopic retinopathy was defined if either staphyloma, lacquer crack, Fuchs' spot or chorioretinal atrophy were present in myopic eyes. Retinal vascular caliber was measured from fundus photographs using standardized methods. The association of retinal vascular caliber with myopic retinopathy was assessed using generalized estimating equation models. A total of 2598 eyes of 1409 subjects were selected from 3654 baseline participants, with 2076 emmetropic eyes (normal controls), 486 myopic eyes without myopic retinopathy (myopic controls) and 36 myopic eyes with myopic retinopathy (cases). After adjusting for age, gender, height, body mass index and blood pressure, eyes with myopic retinopathy had significantly narrower mean arteriolar (166.6μm) and venular caliber (213.3μm), compared to normal (188.1μm and 226.9μm, respectively) or myopic control eyes (190.4μm and 227.0μm, respectively) (all P retinopathy and the two control groups remained significant after additional adjustment for refraction (all P retinopathy is associated with attenuation of retinal vessels.

  15. In the Eye of the Beholder-  A Survey of Models for Eyes and Gaze

    DEFF Research Database (Denmark)

    Witzner Hansen, Dan; Ji, Qiang

    2010-01-01

    Despite active research and significant progress in the last 30 years, eye detection and tracking remains challenging due to the individuality of eyes, occlusion, variability in scale, location, and light conditions. Data on eye location and details of eye movements have numerous applications and...

  16. About the Eye

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  17. Biosocial profile of New Zealand prosthetic eye wearers.

    Science.gov (United States)

    Pine, Keith R; Sloan, Brian; Jacobs, Robert J

    2012-10-12

    To describe the biosocial profile of New Zealand (NZ) artificial eye wearers and establish a basis for future research and international comparison. This retrospective study surveyed 431 NZ artificial eye wearers to investigate their ethnicity, gender, age, causes of eye loss, age of current prosthesis, ocular prosthetic maintenance regimes and the extent and severity of discharge associated with prosthesis wear. Approximately 3000 people wear artificial eyes in NZ. Accidents were the main cause of eye loss prior to 1990 and medical conditions have been the main cause since. In the 1960s, the ratio of men to women losing an eye from accidents was 5:1, but during the past decade the ratio was 1.4:1. Socket discharge occurred at least twice daily for one-third of the study group. Approximately 1 in 1440 people wear artificial eyes in NZ. Decline of eye loss due to accidents is consistent with decreasing workplace and traffic accidents and may be due to improved medical management, workplace safety standards and safer roads. Mucoid discharge is prevalent in the anophthalmic population of NZ and an evidence based treatment protocol for discharge associated with prosthesis wear is needed. Research into this distressing condition is planned.

  18. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  19. About the Eye

    Medline Plus

    Full Text Available ... Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  20. About the Eye

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  1. An Open Conversation on Using Eye-Gaze Methods in Studies of Neurodevelopmental Disorders

    Science.gov (United States)

    Venker, Courtney E.; Kover, Sara T.

    2015-01-01

    Purpose: Eye-gaze methods have the potential to advance the study of neurodevelopmental disorders. Despite their increasing use, challenges arise in using these methods with individuals with neurodevelopmental disorders and in reporting sufficient methodological detail such that the resulting research is replicable and interpretable. Method: This…

  2. Levels of processing and Eye Movements: A Stimulus driven approach

    DEFF Research Database (Denmark)

    Mulvey, Fiona Bríd

    2014-01-01

    movements can be controlled either by bottom up stimulus properties or by top down cognitive control, studies have compared eye movements in real world tasks and searched for indicators of cognitive load or level of attention when task demands increase. Extracting the effects of cognitive processing on eye......The aim of this research is to investigate the explication of levels of attention through eye movement parameters. Previous research from disparate fields have suggested that eye movements are related to cognitive processing, however, the exact nature of the relationship is unclear. Since eye...... to investigate individual differences in levels of processing within the normal population using existing constructs and tests of cognitive style. Study 4 investigates these stimuli and the eye movements of a clinical group with known interruption to the dorsal stream of processing, and subsequent isolated...

  3. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, D. [Toshiba America Medical Systems (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  4. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    International Nuclear Information System (INIS)

    Zhang, D.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  5. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and ...

  6. Eye tracking and nutrition label use

    DEFF Research Database (Denmark)

    Graham, Dan J.; Orquin, Jacob Lund; Visschers, Vivianne H.M.

    2012-01-01

    cameras monitoring consumer visual attention (i.e., eye tracking) has begun to identify ways in which label design could be modified to improve consumers’ ability to locate and effectively utilize nutrition information. The present paper reviews all published studies of nutrition label use that have...... utilized eye tracking methodology, identifies directions for further research in this growing field, and makes research-based recommendations for ways in which labels could be modified to improve consumers’ ability to use nutrition labels to select healthful foods....

  7. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow

    OpenAIRE

    Fogt JS; Jones-Jordan LA; Barr JT

    2018-01-01

    Jennifer S Fogt, Lisa A Jones-Jordan, Joseph T Barr The Ohio State University College of Optometry, Columbus, OH, USA Introduction: New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Materials ...

  8. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  9. The Experimental Study of Safety and Efficacy in Using Bovis Calculus Pharmacopuncture Solution as Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeongsik Seo

    2009-09-01

    rabbits, but dosen't have antibacterial effects on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

  10. Emerging applications of eye-tracking technology in dermatology.

    Science.gov (United States)

    John, Kevin K; Jensen, Jakob D; King, Andy J; Pokharel, Manusheela; Grossman, Douglas

    2018-04-06

    Eye-tracking technology has been used within a multitude of disciplines to provide data linking eye movements to visual processing of various stimuli (i.e., x-rays, situational positioning, printed information, and warnings). Despite the benefits provided by eye-tracking in allowing for the identification and quantification of visual attention, the discipline of dermatology has yet to see broad application of the technology. Notwithstanding dermatologists' heavy reliance upon visual patterns and cues to discriminate between benign and atypical nevi, literature that applies eye-tracking to the study of dermatology is sparse; and literature specific to patient-initiated behaviors, such as skin self-examination (SSE), is largely non-existent. The current article provides a review of eye-tracking research in various medical fields, culminating in a discussion of current applications and advantages of eye-tracking for dermatology research. Copyright © 2018 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  11. Pioneering Studies on Cephalopod's Eye and Vision at the Stazione Zoologica Anton Dohrn (1883-1977).

    Science.gov (United States)

    Dröscher, Ariane

    2016-01-01

    From the late nineteenth century onwards, the phenomena of vision and the anatomy and physiology of the eye of marine animals induced many zoologists, ethologists, physiologists, anatomists, biochemists, and ophthalmologists to travel to the Zoological Station in Naples. Initially, their preferred research objects were fish, but it soon became evident that cephalopods have features which make them particularly suited to research. After the first studies, which outlined the anatomical structure of cephalopods' eyes and optic nerves, the research rapidly shifted to the electrophysiology and biochemistry of vision. In the twentieth century these results were integrated with behavioral tests and training techniques. Between 1909 and 1913 also the well-known debate on color vision between ophthalmologist Carl von Hess and zoologist Karl von Frisch took place in Naples. Largely unknown is that the debate also concerned cephalopods. A comparative historical analysis of these studies shows how different experimental devices, theoretical frameworks, and personal factors gave rise to two diametrically opposing views.

  12. Study of isodose curves of an eye brachytherapy plaque

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Marcos R.O.; Mourao, Arnaldo P., E-mail: marcos.robertto@hotmail.com, E-mail: seg@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Grynberg, Suely E., E-mail: aprata@des.cefetmg.br [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar

    2015-07-01

    The use eye plaque brachytherapy for intraocular tumors treatment is a process designed to protect healthy eye structures, as well as visual functions. It replaces enucleation when possible. The knowledge of the dose spatial distribution inside the eyeball and adjacent structures is very important to obtain the therapeutic dose, minimize the side effects and ensure efficiency in the process. Small variations in positioning the plaque on the ocular surface may generate a less effective treatment. Thus, in this work an eyeball phantom and a seed accommodation system similar to a commercially eye plaque model ROPES with diameter of 15 mm, were developed both in solid water Gammex 457 to conduct the study of the possible variation in the dose deposition inside the eye phantom. Radiochromic films were used to record isodose curves of two orthogonal plans within the simulator. The results showed that there is a difference in the dose deposition for the two orthogonal plans studied. This difference is 8.33% higher for the maximum dose value. Thus, a difference in dose that occurs due to the asymmetrical distribution of seeds on the eye plaque may interfere with the treatment, making it less effective. (author)

  13. Study of isodose curves of an eye brachytherapy plaque

    International Nuclear Information System (INIS)

    Costa, Marcos R.O.; Mourao, Arnaldo P.; Grynberg, Suely E.

    2015-01-01

    The use eye plaque brachytherapy for intraocular tumors treatment is a process designed to protect healthy eye structures, as well as visual functions. It replaces enucleation when possible. The knowledge of the dose spatial distribution inside the eyeball and adjacent structures is very important to obtain the therapeutic dose, minimize the side effects and ensure efficiency in the process. Small variations in positioning the plaque on the ocular surface may generate a less effective treatment. Thus, in this work an eyeball phantom and a seed accommodation system similar to a commercially eye plaque model ROPES with diameter of 15 mm, were developed both in solid water Gammex 457 to conduct the study of the possible variation in the dose deposition inside the eye phantom. Radiochromic films were used to record isodose curves of two orthogonal plans within the simulator. The results showed that there is a difference in the dose deposition for the two orthogonal plans studied. This difference is 8.33% higher for the maximum dose value. Thus, a difference in dose that occurs due to the asymmetrical distribution of seeds on the eye plaque may interfere with the treatment, making it less effective. (author)

  14. Comparison of novel lipid-based eye drops with aqueous eye drops for dry eye: a multicenter, randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Simmons PA

    2015-04-01

    Full Text Available Peter A Simmons, Cindy Carlisle-Wilcox, Joseph G Vehige Ophthalmology Research and Development, Allergan, Inc., Irvine, CA, USA Background: Dry eye may be caused or exacerbated by deficient lipid secretion. Recently, lipid-containing artificial tears have been developed to alleviate this deficiency. Our study compared the efficacy, safety, and acceptability of lipid-containing eye drops with that of aqueous eye drops.Methods: A non-inferiority, randomized, parallel-group, investigator-masked multicenter trial was conducted. Subjects with signs and symptoms of dry eye were randomized to use one of two lipid-containing artificial tears, or one of two aqueous artificial tears. Subjects instilled assigned drops in each eye at least twice daily for 30 days. The primary efficacy analysis tested non-inferiority of a preservative-free lipid tear formulation (LT UD to a preservative-free aqueous tear formulation (AqT UD for change in Ocular Surface Disease Index (OSDI score from baseline at day 30. Secondary measures included OSDI at day 7, tear break-up time (TBUT, corneal and conjunctival staining, Schirmer’s test, acceptability and usage questionnaires, and safety assessments.Results: A total of 315 subjects were randomized and included in the analyses. Subjects reported instilling a median of three doses of study eye drops per day in all groups. At days 7 and 30, all groups showed statistically significant improvements from baseline in OSDI (P<0.001 and TBUT (P≤0.005. LT UD was non-inferior to AqT UD for mean change from baseline in OSDI score at day 30. No consistent or clinically relevant differences for the other efficacy variables were observed. Acceptability was generally similar across the groups and there was a low incidence of adverse events.Conclusion: In this heterogeneous population of dry eye subjects, there were no clinically significant differences in safety, effectiveness, and acceptability between lipid-containing artificial tears

  15. Treatment outcomes in the DRy Eye Amniotic Membrane (DREAM study

    Directory of Open Access Journals (Sweden)

    McDonald MB

    2018-04-01

    Full Text Available Marguerite B McDonald,1 Hosam Sheha,2–5 Sean Tighe,2,3 Susan B Janik,6 Frank W Bowden,7 Amit R Chokshi,8 Michael A Singer,9 Seema Nanda,10 Mujtaba A Qazi,11 Damon Dierker,12 Adam T Shupe,13 Brittany J McMurren14 1Ophthalmic Consultants of Long Island, Lynbrook, NY, USA; 2Ocular Surface Center and TissueTech, Inc., Miami, FL, USA; 3Florida International University Herbert Wertheim College of Medicine, Miami, FL, USA; 4Hofstra University School of Medicine, Hempstead, NY, USA; 5Research Institute of Ophthalmology, Cairo, Egypt; 6Solinsky Eye Care, Kensington, CT, USA; 7Bowden Eye & Associates, Jacksonville, FL, USA; 8Florida Eye Specialists, Jacksonville, FL, USA; 9Medical Center Ophthalmology Associates, San Antonio, TX, USA; 10TX Eye Institute, Houston, TX, USA; 11Pepose Vision Institute, Chesterfield, MO, USA; 12Eye Surgeons of Indiana, Indianapolis, IN, USA; 13Royo Eye Care, Marysville, CA, USA; 14Gordon and Weiss Vision Institute, San Diego, CA, USA Purpose: To evaluate the efficacy of cryopreserved amniotic membrane (CAM in reducing signs and symptoms of dry eye disease (DED in a large patient population. Methods: A retrospective chart review at 10 clinical sites was done of patients with refractory DED who received CAM and completed at least 3 months of follow-up. Data collected were demographics; medical history including previous and current ocular treatment, diagnosis, clinical presentations, comorbidity, duration and frequency of treatment with CAM; and concomitant medications. The primary outcome was the change in dry eye workshop (DEWS score after treatment. Results: A total of 97 eyes of 84 patients exhibited severe dry eye despite maximal medical treatments including topical artificial tears, cyclosporine-A, serum, antibiotics, and steroids. Patients manifested with superficial punctate keratitis (86%, filamentary keratitis (13%, exposure keratitis (19%, neurotrophic keratitis (2%, and corneal epithelial defect (7%. After CAM

  16. How Visual Search Relates to Visual Diagnostic Performance: A Narrative Systematic Review of Eye-Tracking Research in Radiology

    Science.gov (United States)

    van der Gijp, A.; Ravesloot, C. J.; Jarodzka, H.; van der Schaaf, M. F.; van der Schaaf, I. C.; van Schaik, J. P.; ten Cate, Th. J.

    2017-01-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology…

  17. Treatment of Sjögren's syndrome dry eye using 0.03% tacrolimus eye drop: Prospective double-blind randomized study.

    Science.gov (United States)

    Moscovici, Bernardo Kaplan; Holzchuh, Ricardo; Sakassegawa-Naves, Fernando Eiji; Hoshino-Ruiz, Diego Ricardo; Albers, Marcos Bottene Villa; Santo, Ruth Miyuki; Hida, Richard Yudi

    2015-10-01

    To describe the clinical efficacy of the treatment of Sjögren's syndrome dry eye using 0.03% tacrolimus eye drop. Prospective double-blind randomized study. Institutional outpatient clinic. Forty-eight eyes of twenty-four patients with dry eye related to Sjögren syndrome were enrolled in this study. The patients were randomized in 2 groups: tacrolimus (n=14) and vehicle (n=10) group. The tacrolimus group received a vial containing tacrolimus 0.03% (almond oil as vehicle) and the other group received the almond oil vehicle. All patients were instructed to use the eye drops every 12h in the lower conjunctival sac. Schirmer I test, break-up-time (BUT), corneal fluorescein and Rose Bengal staining scores were evaluated in all patients one day before the treatment (baseline), 7, 14, 28 and 90 days after treatment with the eye drops. The average fluorescein and Rose Bengal scores improved statistically after 7 days of treatment and even more after 90 days. The average Schirmer I and BUT values were unchanged after 7, 14 and 21 days but did show an improvement relative to baseline after 28 days of treatment. Schirmer I, BUT, fluorescein and Rose Bengal did not show any statistical significance in the vehicle group. Topical 0.03% tacrolimus eye drop improved tear stability and ocular surface status in cases of inflammatory or SS-related dry eye. ClinicalTrials.gov Identifier: NCT01850979. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Corneal permeability changes in dry eye disease: an observational study.

    Science.gov (United States)

    Fujitani, Kenji; Gadaria, Neha; Lee, Kyu-In; Barry, Brendan; Asbell, Penny

    2016-05-13

    Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. Dry eye patients who have had established signs or symptoms for at least 6 months were included in this observational study. Normal subjects with no symptoms of dry eyes served as controls. Each eye had a baseline fluorescein scan prior to any fluorescein dye. Fluorescein dye was then placed into both eyes, rinsed with saline solution, and scanned at 5, 10, 15, and 30 min. Patients were administered the following diagnostic tests to correlate with fluorophotometry: OSDI, TBUT, fluorescein, and lissamine. Standard protocols were used. P eyes from 25 patients (DED = 22 eyes, 11 patients; Normal = 28 eyes, 14 patients) were included. Baseline scans of the dry eye and control groups did not show any statistical difference (p = 0.84). Fluorescein concentration of DED and normal patients showed statistical significance at all time intervals (p eyes up to 30 min after fluorescein dye instillation. There may be an aspect of DED that is missed in the current regimen of DED tests and only captured with fluorophotometry. Adding fluorophotometry may be useful in screening, diagnosing, and monitoring patients with DED.

  19. Quantitative Assessment of Eye Phenotypes for Functional Genetic Studies Using Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Janani Iyer

    2016-05-01

    Full Text Available About two-thirds of the vital genes in the Drosophila genome are involved in eye development, making the fly eye an excellent genetic system to study cellular function and development, neurodevelopment/degeneration, and complex diseases such as cancer and diabetes. We developed a novel computational method, implemented as Flynotyper software (http://flynotyper.sourceforge.net, to quantitatively assess the morphological defects in the Drosophila eye resulting from genetic alterations affecting basic cellular and developmental processes. Flynotyper utilizes a series of image processing operations to automatically detect the fly eye and the individual ommatidium, and calculates a phenotypic score as a measure of the disorderliness of ommatidial arrangement in the fly eye. As a proof of principle, we tested our method by analyzing the defects due to eye-specific knockdown of Drosophila orthologs of 12 neurodevelopmental genes to accurately document differential sensitivities of these genes to dosage alteration. We also evaluated eye images from six independent studies assessing the effect of overexpression of repeats, candidates from peptide library screens, and modifiers of neurotoxicity and developmental processes on eye morphology, and show strong concordance with the original assessment. We further demonstrate the utility of this method by analyzing 16 modifiers of sine oculis obtained from two genome-wide deficiency screens of Drosophila and accurately quantifying the effect of its enhancers and suppressors during eye development. Our method will complement existing assays for eye phenotypes, and increase the accuracy of studies that use fly eyes for functional evaluation of genes and genetic interactions.

  20. Moving eyes and naming objects

    NARCIS (Netherlands)

    Meulen, F.F. van der

    2001-01-01

    The coordination between eye movements and speech was examined while speakers were naming objects. Earlier research has shown that eye movements reflect on the underlying visual attention. Also, eye movements were found to reflect upon not only the visual and conceptual processing of an object, but

  1. 1st Workshop on Eye Tracking and Visualization

    CERN Document Server

    Chuang, Lewis; Fisher, Brian; Schmidt, Albrecht; Weiskopf, Daniel

    2017-01-01

    This book discusses research, methods, and recent developments in the interdisciplinary field that spans research in visualization, eye tracking, human-computer interaction, and psychology. It presents extended versions of papers from the First Workshop on Eye Tracking and Visualization (ETVIS), which was organized as a workshop of the IEEE VIS Conference 2015. Topics include visualization and visual analytics of eye-tracking data, metrics and cognitive models, eye-tracking experiments in the context of visualization interfaces, and eye tracking in 3D and immersive environments. The extended ETVIS papers are complemented by a chapter offering an overview of visualization approaches for analyzing eye-tracking data and a chapter that discusses electrooculography (EOG) as an alternative of acquiring information about eye movements. Covering scientific visualization, information visualization, and visual analytics, this book is a valuable resource for eye-tracking researchers within the visualization community.

  2. Eye Movement Indices in the Study of Depressive Disorder.

    Science.gov (United States)

    Li, Yu; Xu, Yangyang; Xia, Mengqing; Zhang, Tianhong; Wang, Junjie; Liu, Xu; He, Yongguang; Wang, Jijun

    2016-12-25

    Impaired cognition is one of the most common core symptoms of depressive disorder. Eye movement testing mainly reflects patients' cognitive functions, such as cognition, memory, attention, recognition, and recall. This type of testing has great potential to improve theories related to cognitive functioning in depressive episodes as well as potential in its clinical application. This study investigated whether eye movement indices of patients with unmedicated depressive disorder were abnormal or not, as well as the relationship between these indices and mental symptoms. Sixty patients with depressive disorder and sixty healthy controls (who were matched by gender, age and years of education) were recruited, and completed eye movement tests including three tasks: fixation task, saccade task and free-view task. The EyeLink desktop eye tracking system was employed to collect eye movement information, and analyze the eye movement indices of the three tasks between the two groups. (1) In the fixation task, compared to healthy controls, patients with depressive disorder showed more fixations, shorter fixation durations, more saccades and longer saccadic lengths; (2) In the saccade task, patients with depressive disorder showed longer anti-saccade latencies and smaller anti-saccade peak velocities; (3) In the free-view task, patients with depressive disorder showed fewer saccades and longer mean fixation durations; (4) Correlation analysis showed that there was a negative correlation between the pro-saccade amplitude and anxiety symptoms, and a positive correlation between the anti-saccade latency and anxiety symptoms. The depression symptoms were negatively correlated with fixation times, saccades, and saccadic paths respectively in the free-view task; while the mean fixation duration and depression symptoms showed a positive correlation. Compared to healthy controls, patients with depressive disorder showed significantly abnormal eye movement indices. In addition

  3. Eye Disease and Development

    DEFF Research Database (Denmark)

    Andersen, Thomas Barnebeck; Dalgaard, Carl-Johan Lars; Selaya, Pablo

    This research advances the hypothesis that cross-country variation in the historical incidence of eye disease has influenced the current global distribution of per capita income. The theory is that pervasive eye disease diminished the incentive to accumulate skills, thereby delaying the fertility...... transition and the take-off to sustained economic growth. In order to estimate the influence from eye disease incidence empirically, we draw on an important fact from the field of epidemiology: Exposure to solar ultraviolet B radiation (UVB-R) is an underlying determinant of several forms of eye disease...

  4. [Pathogenetic relationship between pterygium and dry eye syndrome (clinical and cytological study)].

    Science.gov (United States)

    Petraevskiĭ, A V; Trishkin, K S

    2014-01-01

    To study the prevalence of dry eye syndrome in patients with initial primary pterygium for determination of a possible pathogenetic role of dry eye syndrome in the development of pterygium. 30 patients with initial primary pterygium; besides conventional ophthalmic assessment, cytological examination of bulbar conjunctiva was performed in all cases. Signs of dry eye syndrome, of similar severity in both eyes, were found in 100% of patients. Dry eye can be one of the precipitating factors of primary pterygium.

  5. Challenges in horizontal integration of eye care services into the pre-existing rural primary care structure: an operations research perspective from Nigeria

    Directory of Open Access Journals (Sweden)

    Chinyere Nkemdilim Ezisi

    2017-12-01

    Full Text Available Background . The provision of population-wide, accessible, affordable, acceptable and evenly distributed qualitative eye care services remains a recurrent challenge to eye care organizations worldwide. Objectives . To report the challenges encountered in setting up eye care service in a pre-existing primary health care facility in rural Nigeria and also audit the common causes of eye disorders in rural setting southeast of Nigeria. Material and methods . The study was an operations research study conducted at Akpuoga-Nike between February and April 2011. Demographic and ophthalmic clinical data were collected. Health system-, community- and patient-determined challenges were catalogued and analyzed using Epi Info Statistical software for Windows, version 6. Univariate analysis was performed for data distribution testing. Analytical statistics were performed, with p < 0.05 considered statistically significant. Results . A total of 481 (males, 144 (29.9%; females, 377(70.1% patients aged 42.3 ± 20.2 SD years (range 4–80 years were seen. The leading eye disorders were refractive error – 28.9%, and cataract – 16.4%. The operations challenges encountered included difficulties with community sensitization/advocacies, inadequate infrastructure and mobile equipment, as well as lack of eye care manpower, consumables and funding deficits. Conclusions . Health system-related issues were the main challenges encountered. Recruitment of an adequate number of rural eye care workforce, provision of needed material resources, adequate funding and engendering community participation in rural eye care delivery through grass roots advocacy and health service public education would overcome the challenges.

  6. Sex differences in a virtual water maze: an eye tracking and pupillometry study.

    Science.gov (United States)

    Mueller, Sven C; Jackson, Carl P T; Skelton, Ron W

    2008-11-21

    Sex differences in human spatial navigation are well known. However, the exact strategies that males and females employ in order to navigate successfully around the environment are unclear. While some researchers propose that males prefer environment-centred (allocentric) and females prefer self-centred (egocentric) navigation, these findings have proved difficult to replicate. In the present study we examined eye movements and physiological measures of memory (pupillometry) in order to compare visual scanning of spatial orientation using a human virtual analogue of the Morris Water Maze task. Twelve women and twelve men (average age=24 years) were trained on a visible platform and had to locate an invisible platform over a series of trials. On all but the first trial, participants' eye movements were recorded for 3s and they were asked to orient themselves in the environment. While the behavioural data replicated previous findings of improved spatial performance for males relative to females, distinct sex differences in eye movements were found. Males tended to explore consistently more space early on while females demonstrated initially longer fixation durations and increases in pupil diameter usually associated with memory processing. The eye movement data provides novel insight into differences in navigational strategies between the sexes.

  7. Morphological study of the eye and adnexa in capuchin monkeys (Sapajus sp..

    Directory of Open Access Journals (Sweden)

    Danielle Nascimento Silva

    Full Text Available The objective of this study was to describe the anatomic and histologic features of the Sapajus sp. eye, comparing similarities and differences of humans and other species of non-human primates for biomedical research purposes. Computed tomography (CT of adnexa, eye and orbit live animal, as well as formolized pieces of the same structures of Sapajus sp. for anatomical and histological study were also performed. The anatomical description of the eye and adnexa was performed using the techniques of topographic dissection and exenteration. Histological fragments were fixated in buffered formalin 10%, processed by the routine paraffin inclusion technique, stained with hematoxylin-eosin and special stains. CT scan evaluation showed no differences between the live animal and the formolized head on identification of visual apparatus structures. Anatomic and histologic evaluation revealed rounded orbit, absence of the supraorbital foramen and frontal notch, little exposure of the sclera, with slight pigmentation of the exposed area and marked pigmentation at the sclerocorneal junction. Masson's Trichrome revealed the Meibomian glands, the corneal epithelium and Bowman's membrane; in the choroid, melanocytes and Bruch's membrane were observed; and in the retina, cones and rods as well as, optic nerve, the lamina cribrosa of the nerve fibers bundles. Toluidine blue highlighted the membranes: Bowman, Descemet and the endothelium; in the choroid: melanocytes; and in the retina: nuclear layers and retinal pigment epithelium. In view of the observed results Sapajus sp. is an important experimental model for research in the ophthalmology field, which has been shown due to the high similarity of its anatomical and histological structures with the human species.

  8. Dry eyes: etiology and management.

    Science.gov (United States)

    Latkany, Robert

    2008-07-01

    Until recently, the cause of dry eye syndrome was uncertain and the treatment was palliative. Since discovering that dry eyes are caused by inflammation, there has been an abundance of research focusing on anti-inflammatory therapies, other contributing causes, and better diagnostic testing. This review summarizes some of the interesting published research on ocular surface disease over the past year. The definition of dry eye now highlights the omnipresent symptom of blurry vision. The re-evaluation of ocular surface staining, tear meniscus height, and visual change will allow for a better diagnosis and understanding of dry eyes. Punctal plugs, and oral and topical anti-inflammatory use will strengthen our arsenal against ocular surface disease. Major progress has occurred in the past few years in gaining a better understanding of the etiology of dry eye syndrome, which will inevitably lead to more effective therapeutic options.

  9. Gonioscopy in adult Chinese: the Liwan Eye Study.

    Science.gov (United States)

    He, Mingguang; Foster, Paul J; Ge, Jian; Huang, Wenyong; Wang, Dandan; Friedman, David S; Khaw, Peng T

    2006-11-01

    To assess gonioscopic characteristics of the drainage angle in adult Chinese in an urban area of southern China. Clustered random sampling was used to select adults aged 50 years and older in Liwan District, Guangzhou. Gonioscopy was performed on all the subjects. The geometric angle width was graded in the superior and inferior quadrants, according to the Spaeth system. In addition, apparent and true iris insertion was classified in four quadrants with static and dynamic gonioscopy. The peripheral iris profile was described as steep, regular, concave, and plateau. Data are presented for all phakic right eyes. Secondary or iatrogenic cases were excluded in the analysis of peripheral anterior synechiae (PAS). Among 1405 participants in the study, data from 1330 (95%) right eyes were available for analysis. Iridotrabecular angles (ITA) < or =20 degrees were present in 36.9% (95% CI: 34.3%-40.0%) of eyes superiorly and in 27.9% (95% CI: 25.5%-30.4%) inferiorly. Narrower ITAs were more common in the older people (sex-adjusted odds ratio [OR] = 1.1 per year of life; P < 0.001) and the women (age-adjusted OR = 2.5, P < 0.001). Apparent iris insertion of grade A or B (with pigmented trabecular meshwork not visible) by quadrant was observed in 27.2% superiorly, 12.0% nasally, 7.7% inferiorly, and 14.2% temporally. Narrow angles (in which pigmented trabecular meshwork was not visible in three or more quadrants) were identified in 11.0% (95% CI: 9.3%-12.7%) of right eyes. Overall, 33.3% of eyes had a steep iris profile, 54.2% were normal, 2.7% were concave, and 10.1% were graded plateau. PAS were seen in 30 of 146 (20.5%) eyes with narrow angles and in 7 (0.6%) of 1184 eyes with angles that did not meet criteria for narrow angles. PAS were more likely with narrower angles, with 0%, 0.3%, and 1.9% of eyes with a mean ITA of 40 degrees, 30 degrees, and 20 degrees, respectively, having PAS as opposed to 12.6% and 27.5% for those with ITA 10 degrees and 0 degrees , respectively

  10. Wave study of compound eyes for efficient infrared detection

    Science.gov (United States)

    Kilinc, Takiyettin Oytun; Hayran, Zeki; Kocer, Hasan; Kurt, Hamza

    2017-08-01

    Improving sensitivity in the infrared spectrum is a challenging task. Detecting infrared light over a wide bandwidth and at low power consumption is very important. Novel solutions can be acquired by mimicking biological eyes such as compound eye with many individual lenses inspired from the nature. The nature provides many ingenious approaches of sensing and detecting the surrounding environment. Even though compound eye consists of small optical units, it can detect wide-angle electromagnetic waves and it has high transmission and low reflection loss. Insects have eyes that are superior compared to human eyes (single-aperture eyes) in terms of compactness, robustness, wider field of view, higher sensitivity of light intensity and being cheap vision systems. All these desired properties are accompanied by an important drawback: lower spatial resolution. The first step to investigate the feasibility of bio-inspired optics in photodetectors is to perform light interaction with the optical system that gather light and detect it. The most common method used in natural vision systems is the ray analysis. Light wave characteristics are not taken into consideration in such analyses, such as the amount of energy at the focal point or photoreceptor site, the losses caused by reflection at the interfaces and absorption cannot be investigated. In this study, we present a bio-inspired optical detection system investigated by wave analysis. We numerically model the wave analysis based on Maxwell equations from the viewpoint of efficient light detection and revealing the light propagation after intercepting the first interface of the eye towards the photoreceptor site.

  11. From basic to applied research to improve outcomes for individuals who require augmentative and alternative communication: potential contributions of eye tracking research methods.

    Science.gov (United States)

    Light, Janice; McNaughton, David

    2014-06-01

    In order to improve outcomes for individuals who require AAC, there is an urgent need for research across the full spectrum--from basic research to investigate fundamental language and communication processes, to applied clinical research to test applications of this new knowledge in the real world. To date, there has been a notable lack of basic research in the AAC field to investigate the underlying cognitive, sensory perceptual, linguistic, and motor processes of individuals with complex communication needs. Eye tracking research technology provides a promising method for researchers to investigate some of the visual cognitive processes that underlie interaction via AAC. The eye tracking research technology automatically records the latency, duration, and sequence of visual fixations, providing key information on what elements attract the individual's attention (and which ones do not), for how long, and in what sequence. As illustrated by the papers in this special issue, this information can be used to improve the design of AAC systems, assessments, and interventions to better meet the needs of individuals with developmental and acquired disabilities who require AAC (e.g., individuals with autism spectrum disorders, Down syndrome, intellectual disabilities of unknown origin, aphasia).

  12. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies.

    Science.gov (United States)

    Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  13. Study on the distribution of the dominant eye in people with myopia and astigmatism and the relationship between dominant eye and the two

    Directory of Open Access Journals (Sweden)

    Wen-Li Duan

    2015-11-01

    Full Text Available AIM:To study the distribution of the dominant eye in people with myopia and astigmatism and the relationship between dominant eye and the two. METHODS:Three hundred and eighty patients who went our hospital for optometry consecutively were enrolled, using hole-in-card method to detect the dominant eye. The records of age, gender, vision acuity and other related information were analyzed by SPSS 11.0 software. RESULTS: 1Most of the dominant eyes were right eyes which accounted for 66.84%, and the ametropia degree on right eyes was relatively higher; 2Dominant eyes had no significant association with gender, age and uncorrected vision acuity(P>0.05; 3There was no significant correlation between the dominant eyes and ametropia degree(P>0.05. But in the group which the difference of cylinder degree between two eyes were ≥1D, only 20% of the dominant eyes had higher ametropia degree, which was different from the other two groups. CONCLUSION:High cylinder of anisometropia may affect the choice of the dominant eye. High sphere of anisometropia may be the result of the choice of dominant eye.

  14. The study of myocardial ischemic quality with weighted-subtraction-bull's-eye analysis

    International Nuclear Information System (INIS)

    Chen Wuduan; Tian Jiahe; Hou Qingtian

    1993-01-01

    Weighted-Subtraction-Bull's-eye analysis was studied in 33 normal subjects and 58 patients with coronary artery disease after dipyridamole 99m Tc-MIBI myocardial SPECT imaging. Two kinds of Bull's-eye were produced: (1) subtract rest from 1.2 times dipyridamole from 1.2 times rest Bull's-eye; (2) subtract dipyridamole Bull's-eye. The results showed that the weighted-subtraction-Bull's-eye could clearly displayed the location and puality of ischemic myocardium. And also 74% segments showed so called combined ischemic i.e the blood perfusion reduced, increased and sustained simultaneously after dipyridamole. Therefore weighted-subtraction-Bull's-eye analysis had provided a new method for determination of the quality of ischemia

  15. Enhancing a CAVE with Eye Tracking System for Human-Computer Interaction Research in 3D Visualization

    National Research Council Canada - National Science Library

    Hix, Deborah

    1999-01-01

    The objective of this award was to purchase and install two ISCAN Inc. Eye Tracking Systems and associated equipment to create a unique set-up for research in fully immersive virtual environments (VEs...

  16. SyntEyes KTC: higher order statistical eye model for developing keratoconus.

    Science.gov (United States)

    Rozema, Jos J; Rodriguez, Pablo; Ruiz Hidalgo, Irene; Navarro, Rafael; Tassignon, Marie-José; Koppen, Carina

    2017-05-01

    To present and validate a stochastic eye model for developing keratoconus to e.g. improve optical corrective strategies. This could be particularly useful for researchers that do not have access to original keratoconic data. The Scheimpflug tomography, ocular biometry and wavefront of 145 keratoconic right eyes were collected. These data were processed using principal component analysis for parameter reduction, followed by a multivariate Gaussian fit that produces a stochastic model for keratoconus (SyntEyes KTC). The output of this model is filtered to remove the occasional incorrect topography patterns by either an automatic or manual procedure. Finally, the output of this keratoconus model is matched to that of the original model for normal eyes using the non-corneal biometry to obtain a description of keratoconus development. The synthetic data generated by the model were found to be significantly equal to the original data (non-parametric Mann-Whitney equivalence test; 145/154 passed). The variability of the synthetic data, however, was often significantly less than that of the original data, especially for the higher order Zernike terms of corneal elevation (non-parametric Levene test; p eyes with incorrect topographies. Interpolation between matched pairs of normal and keratoconic SyntEyes appears to provide an adequate model for keratoconus progression. The synthetic data provided by the proposed keratoconus model closely resembles actual clinical data and may be used for a range of research applications when (sufficient) real data is not available. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  17. Pioneering Studies on Cephalopod's Eye and Vision at the Stazione Zoologica Anton Dohrn (1883-1977)

    OpenAIRE

    Dr?scher, Ariane

    2016-01-01

    From the late nineteenth century onwards, the phenomena of vision and the anatomy and physiology of the eye of marine animals induced many zoologists, ethologists, physiologists, anatomists, biochemists, and ophthalmologists to travel to the Zoological Station in Naples. Initially, their preferred research objects were fish, but it soon became evident that cephalopods have features which make them particularly suited to research. After the first studies, which outlined the anatomical structur...

  18. Eye tracking in user experience design

    CERN Document Server

    Romano Bergstorm, Jennifer

    2014-01-01

    Eye Tracking for User Experience Design explores the many applications of eye tracking to better understand how users view and interact with technology. Ten leading experts in eye tracking discuss how they have taken advantage of this new technology to understand, design, and evaluate user experience. Real-world stories are included from these experts who have used eye tracking during the design and development of products ranging from information websites to immersive games. They also explore recent advances in the technology which tracks how users interact with mobile devices, large-screen displays and video game consoles. Methods for combining eye tracking with other research techniques for a more holistic understanding of the user experience are discussed. This is an invaluable resource to those who want to learn how eye tracking can be used to better understand and design for their users. * Includes highly relevant examples and information for those who perform user research and design interactive experi...

  19. A HOSPITAL-BASED STUDY ON THE PREVALENCE OF DRY EYES IN A TERTIARY CARE HOSPITAL

    Directory of Open Access Journals (Sweden)

    Prashant V. Solanke

    2017-06-01

    Full Text Available BACKGROUND Dry eye syndrome is a common eye disease. Dry Eye Syndrome (DES, also known as Keratoconjunctivitis Sicca (KCS, is the condition of having dry eyes. Other associated symptoms include irritation, redness, discharge and easily fatigued eyes. Blurred vision may also occur. The symptoms can range from mild and occasional to severe and continuous. Scarring of the cornea may occur in some cases without treatment. Dry eye occurs when either the eye does not produce enough tears or when the tears evaporate too quickly. Tobacco smoke exposure or infection may also lead to the condition. Diagnosis is mostly based on the symptoms, though a number of other tests may be used. Prevalence of dry eyes are commoner in females than males. There is a positive relationship between glaucoma and ocular dryness as well as diabetic retinopathy and ocular dryness. Dry eye is a multifactorial disease of the tears and ocular surface. Ocular symptoms such as pain, irritation and poor vision can result from dry eye. The aim of the study is to study the prevalence, symptomatology and distribution of dry eyes. MATERIALS AND METHODS A cross-sectional study was conducted during July 2016 to March 2017. Study place was Outpatient Department of Ophthalmology at Sree Mookambika Institute of Medical Sciences, Kulasekharam. Sample size was calculated by 4PQ/d², which was 132. Systemic random sampling was used for the study. RESULTS Prevalence of dry eyes - 17.8%. Dry eyes in males - 16.8% and in females - 24.6%. Dry eyes in age 40 yrs. - 21.8%. Prevalence of dry eyes in contact lens wearers - 36.5%. Prevalence of dry eyes in glaucoma cases - 38.2%. Prevalence of dry eyes in farmers - 27.3%, in smokers - 36.7%. Dry eyes in emmetropes - 12.8% in myopes - 17.2% in hypermetropes - 28.6%. CONCLUSION Dry eyes prevalence obtained was 17.8%. Dry eyes were seen more in females. As age increases, prevalence of dry eyes increases. Ocular surface dryness was observed more in contact

  20. The Growing Need for Validated Biomarkers and Endpoints for Dry Eye Clinical Research.

    Science.gov (United States)

    Roy, Neeta S; Wei, Yi; Kuklinski, Eric; Asbell, Penny A

    2017-05-01

    Biomarkers with minimally invasive and reproducible objective metrics provide the key to future paradigm shifts in understanding of the underlying causes of dry eye disease (DED) and approaches to treatment of DED. We review biomarkers and their validity in providing objective metrics for DED clinical research and patient care. The English-language literature in PubMed primarily over the last decade was surveyed for studies related to identification of biomarkers of DED: (1) inflammation, (2) point-of-care, (3) ocular imaging, and (4) genetics. Relevant studies in each group were individually evaluated for (1) methodological and analytical details, (2) data and concordance with other similar studies, and (3) potential to serve as validated biomarkers with objective metrics. Significant work has been done to identify biomarkers for DED clinical trials and for patient care. Interstudy variation among studies dealing with the same biomarker type was high. This could be attributed to biologic variations and/or differences in processing, and data analysis. Correlation with other signs and symptoms of DED was not always clear or present. Many of the biomarkers reviewed show the potential to serve as validated and objective metrics for clinical research and patient care in DED. Interstudy variation for a given biomarker emphasizes the need for detailed reporting of study methodology, including information on subject characteristics, quality control, processing, and analysis methods to optimize development of nonsubjective metrics. Biomarker development offers a rich opportunity to significantly move forward clinical research and patient care in DED. DED is an unmet medical need - a chronic pain syndrome associated with variable vision that affects quality of life, is common with advancing age, interferes with the comfortable use of contact lenses, and can diminish results of eye surgeries, such as cataract extraction, LASIK, and glaucoma procedures. It is a worldwide

  1. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    Directory of Open Access Journals (Sweden)

    Anna K. Nowinska

    2015-01-01

    Full Text Available Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT in eyes with corneal dystrophies (CDs. Methods. Fifty healthy volunteers (50 eyes and 54 patients (96 eyes diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT, anterior chamber depth (ACD, and nasal and temporal trabecular iris angle (nTIA, tTIA were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  2. The Nine-Step Minnesota Grading System for Eyebank Eyes With Age Related Macular Degeneration: A Systematic Approach to Study Disease Stages.

    Science.gov (United States)

    Olsen, Timothy W; Liao, Albert; Robinson, Hershonna S; Palejwala, Neal V; Sprehe, Nicholas

    2017-10-01

    To refine the Minnesota Grading System (MGS) using definitions from the Age-Related Eye Disease Studies (AREDS) into a nine-step grading scale (MGS-9). A nine-step grading scale descriptive analysis using three key phenotypic features (total drusen area, increased, and decreased pigmentation) of human eyebank eyes that were graded according to definitions from the AREDS criteria in order to harmonize studies of disease progression for research involving human tissue. From 2005 through February 2017, we have analyzed 1159 human eyes, procured from two eyebanks. Each macula was imaged using high-resolution, stereoscopic color fundus photography with both direct- and transillumination. Fundus images were digitally overlaid with a grading template and triangulated for foveal centration. We documented and stratified risk for each globe by applying the AREDS nine-step grading scale to the key clinical features from the MGS-9. We found a good distribution within the MGS categories (1-9) with few level eight globes. Eyes were processed within 12.1 ± 6.3, hours from the time of death through imaging, dissection, and freezing or fixation. Applying the MGS-9 to 331 pairs (662 eyes were simultaneously graded), 84% were within one-grading step and 93% within two steps of the fellow eye. We also document reticular pseudodrusen, basal laminar drusen, and pattern dystrophy. The MGS nine-step grading scale enables researchers using human tissue to refine the risk assessment of donor tissue. This analysis will harmonize results among researchers when grading human tissue using MGS criteria. Most importantly, the MGS-9 links directly to the known risk for progression from the AREDS.

  3. Efficacy of topical cyclosporine 0.05% eye drops in the treatment of dry eyes

    OpenAIRE

    Haitham Y Al-Nashar

    2015-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of cyclosporine 0.05% in the treatment of dry-eye disease. Patients and methods A total of 35 eyes of 20 patients with dry-eye disease were included in the present study. Ten patients (20 eyes) had dry eyes associated with systemic rheumatologic disease (Sjögren′s syndrome), five patients (10 eyes) had dry eyes after undergoing laser in-situ keratomileusis, and five patients (five eyes) had dry eyes after cataract...

  4. Application of eye-tracking in the testing of drivers: A review of research

    Directory of Open Access Journals (Sweden)

    Bronisław Kapitaniak

    2015-12-01

    Full Text Available Recording and analyzing eye movements provide important elements for understanding the nature of the task of driving a vehicle. This article reviews the literature on eye movement strategies employed by drivers of vehicles (vehicle control, evaluation of the situation by analyzing essential visual elements, navigation. Special focus was placed on the phenomenon of conspicuity, the probability of perceiving an object in the visual field and the factors that determine it. The article reports the methods of oculographic examination, with special emphasis on the non-invasive technique using corneal reflections, and the criteria for optimal selection of the test apparatus for drivers in experimental conditions (on a driving simulator and in real conditions. Particular attention was also paid to the helmet – or glass-type devices provided with 1 or 2 high definition (HD camcorders recording the field of vision and the direction of gaze, and the non-contact devices comprising 2 or 3 cameras and an infrared source to record eye and head movements, pupil diameter, eye convergence distance, duration and frequency of eyelid blinking. A review of the studies conducted using driver eye-tracking procedure was presented. The results, in addition to their cognitive value, can be used with success to optimize the strategy of drivers training.

  5. Insights into numerical cognition: considering eye-fixations in number processing and arithmetic.

    Science.gov (United States)

    Mock, J; Huber, S; Klein, E; Moeller, K

    2016-05-01

    Considering eye-fixation behavior is standard in reading research to investigate underlying cognitive processes. However, in numerical cognition research eye-tracking is used less often and less systematically. Nevertheless, we identified over 40 studies on this topic from the last 40 years with an increase of eye-tracking studies on numerical cognition during the last decade. Here, we review and discuss these empirical studies to evaluate the added value of eye-tracking for the investigation of number processing. Our literature review revealed that the way eye-fixation behavior is considered in numerical cognition research ranges from investigating basic perceptual aspects of processing non-symbolic and symbolic numbers, over assessing the common representational space of numbers and space, to evaluating the influence of characteristics of the base-10 place-value structure of Arabic numbers and executive control on number processing. Apart from basic results such as reading times of numbers increasing with their magnitude, studies revealed that number processing can influence domain-general processes such as attention shifting-but also the other way round. Domain-general processes such as cognitive control were found to affect number processing. In summary, eye-fixation behavior allows for new insights into both domain-specific and domain-general processes involved in number processing. Based thereon, a processing model of the temporal dynamics of numerical cognition is postulated, which distinguishes an early stage of stimulus-driven bottom-up processing from later more top-down controlled stages. Furthermore, perspectives for eye-tracking research in numerical cognition are discussed to emphasize the potential of this methodology for advancing our understanding of numerical cognition.

  6. Design of a population-based study of visual impairment in India : The Andhra Pradesh eye disease study

    Directory of Open Access Journals (Sweden)

    Dandona Rakhi

    1997-01-01

    Full Text Available Reliable population-based epidemiologic data regarding vision and ocular morbidity, as well as those about the perceptions of people regarding visual impairment and eye care, are lacking for the most part in the developing world including India. These data are the basis on which effective eye care services can be developed. To meet this need we designed the Andhra Pradesh Eye Disease Study, a population-based epidemiology study of 10,000 people in the Indian state of Andhra Pradesh. The design of this study is described in this paper. Various options for the sample size, study areas, sampling procedure, and recruitment of subjects were considered. A sample size of 10,000 people, 5,000 each in the < or = 30 and > 30 years age groups, was determined to obtain reasonable confidence in estimating the prevalence of diseases and odds ratios for risk factors of interest. A multistage sampling strategy was chosen for the study which was assumed to give a design effect of 1.5 for the estimates. One urban area, Hyderabad, and three rural areas, West Godavari, Adilabad and Mahbubnagar districts, were selected in Andhra Pradesh. Interview instruments were developed to obtain detailed information about demographic data, diet, ocular and systemic history, risk factors for eye diseases, visual function, quality of life, barriers to eye care, and knowledge about eye diseases. A detailed examination procedure was devised to obtain a broad range of normative and abnormal data related to eyes and vision. A protocol was developed for doing automated visual fields, slitlamp and fundus photography. Computer databases were made in FoxPro for data entry and subsequent analysis with SPSS. Pilot studies were done to test the instruments, procedures, and logistics of the study in urban and rural areas. Information from the Andhra Pradesh Eye Disease Study is expected to help in planning and implementation of effective long-term preventive, curative, and

  7. Greek mythology: the eye, ophthalmology, eye disease, and blindness.

    Science.gov (United States)

    Trompoukis, Constantinos; Kourkoutas, Dimitrios

    2007-06-01

    In distant eras, mythology was a form of expression used by many peoples. A study of the Greek myths reveals concealed medical knowledge, in many cases relating to the eye. An analysis was made of the ancient Greek texts for mythological references relating to an understanding of vision, visual abilities, the eye, its congenital and acquired abnormalities, blindness, and eye injuries and their treatment. The Homeric epics contain anatomical descriptions of the eyes and the orbits, and an elementary knowledge of physiology is also apparent. The concept of the visual field can be seen in the myth of Argos Panoptes. Many myths describe external eye disease ("knyzosis"), visual disorders (amaurosis), and cases of blinding that, depending on the story, are ascribed to various causes. In addition, ocular motility abnormalities, congenital anomalies (cyclopia), injuries, and special treatments, such as the "licking" method, are mentioned. The study of mythological references to the eye reveals reliable medical observations of the ancient Greeks, which are concealed within the myths.

  8. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation.

    Science.gov (United States)

    Abdul, Latif; Abdul, Razique; Sukul, R R; Nazish, Siddiqui

    2010-01-01

    The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and antiallergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  9. Genetic Testing and Eye Disease

    Science.gov (United States)

    ... condition called Cogan’s syndrome. Google AI May Reveal Health Risks Through Your Eyes FEB 20, 2018 By Ari Soglin Researchers at Google say a new application of artificial intelligence shows whether a patient’s eyes point to high ...

  10. Phantom Eye Syndrome: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    Agda M. Andreotti

    2014-01-01

    Full Text Available The purpose of this literature review was to describe the main features of phantom eye syndrome in relation to their possible causes, symptoms, treatments, and influence of eye amputation on quality of life of anophthalmic patients. For this, a bibliographical research was performed in Pubmed database using the following terms: “eye amputation,” “eye trauma,” “phantom eye syndrome,” “phantom pain,” and “quality of life,” associated or not. Thirteen studies were selected, besides some relevant references contained in the selected manuscripts and other studies hallowed in the literature. Thus, 56 articles were included in this review. The phantom eye syndrome is defined as any sensation reported by the patient with anophthalmia, originated anophthalmic cavity. In phantom eye syndrome, at least one of these three symptoms has to be present: phantom vision, phantom pain, and phantom sensations. This syndrome has a direct influence on the quality of life of the patients, and psychological support is recommended before and after the amputation of the eyeball as well as aid in the treatment of the syndrome. Therefore, it is suggested that, for more effective treatment of phantom eye syndrome, drug therapy should be associated with psychological approach.

  11. Eye movement identification based on accumulated time feature

    Science.gov (United States)

    Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua

    2017-06-01

    Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.

  12. Eye-closure increases children’s memory accuracy for visual material

    NARCIS (Netherlands)

    Mastroberardino, S.; Vredeveldt, A.

    2014-01-01

    Research shows that closing the eyes during retrieval can help both adults and children to remember more about witnessed events. In this study, we investigated whether the eye-closure effect in children is explained by general cognitive load, modality-specific interference, or a combination. 120

  13. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for ...

  14. Psychophysiological Responsivity to Script-Driven Imagery: An Exploratory Study of the Effects of Eye Movements on Public Speaking Flashforwards.

    Science.gov (United States)

    Kearns, Michelle; Engelhard, Iris M

    2015-01-01

    A principle characteristic of public speaking anxiety relates to intrusive mental images of potential future disasters. Previous research has found that the self-reported emotionality of such "flashforwards" can be reduced by a cognitively demanding, dual-task (e.g., making eye movements) performed whilst holding the mental image in-mind. The outcome measure in these earlier studies was participants' self-reported emotional intensity of the mental image. The current study (N = 34) explored whether an objective measure of emotionality would yield similar results in students with public speaking anxiety. A script-driven imagery procedure was used to measure psychophysiological responsivity to an audio script depicting a feared (public speaking) scenario before and after an eye movement intervention. Relative to the control condition (imagery only), those who made eye movements whilst holding a mental image of this scenario in-mind demonstrated a significant decrease in heart rate, which acted as a measure of emotionality. These findings add to a previous body of research demonstrating the beneficial qualities of dual-tasks and their potential for treatment of both past and future-oriented anxieties.

  15. Clinical features and prognosis of eyeball rupture: eye injury vitrectomy study.

    Science.gov (United States)

    Feng, Kang; Wang, Chang-guan; Hu, Yun-tao; Yao, Yi; Jiang, Yan-rong; Shen, Li-jun; Pang, Xiu-qin; Nie, Hong-ping; Ma, Zhi-zhong

    2015-01-01

    The objective of the study was to delineate clinical characteristics, surgical interventions, anatomic and visual outcomes of ruptured eye balls after trauma, and establish the prognostic indicators, which can assist clinicians in making correct surgical decisions during globe exploration for ruptured eyes. The study design used was a multicentre prospective cohort study, including six university-affiliated tertiary hospitals. We selected 242 cases of ruptured globe from the Eye Injury Vitrectomy Study database, until 31 December 2012. All selected cases underwent vitreoretinal surgery, enucleation or evisceration, and were followed up for at least 6 months. Age, visual acuity (VA) after injury, ocular trauma zone, time to surgery, corneal laceration, scleral wound, extrusion of iris or lens, ciliary body damage, intraocular haemorrhage, retinal detachment or defect, proliferative vitreoretinopathy (PVR) and choroidal damage were the predisposing factors evaluated by logistic regression models. We compared the pre-surgical indicators between cases of anatomically restored eyes with VA of 4/200 or better, or eyes with initial no light perception restored light perception or better, and cases of VA worse than 4/200, silicone oil-sustained eyes, phthisis or enucleation. Nearly 40% of cases with ruptured globe were anatomically restored through vitreoretinal surgery. The closed-funnel retinal detachment or extensive retinal loss (odds ratio [OR] = 3.38, P = 0.026), PVR-C (OR = 3.45, P = 0.008), and choroidal damage (OR = 4.20, P = 0.004) were correlated with poor outcomes. The closed-funnel retinal detachment or extensive retinal loss, PVR-C, and choroidal damage are the risk factors for unfavourable outcomes in globe ruptures. © 2015 Royal Australian and New Zealand College of Ophthalmologists.

  16. Diquafosol ophthalmic solution for dry eye treatment.

    Science.gov (United States)

    Nakamura, Masatsugu; Imanaka, Takahiro; Sakamoto, Asuka

    2012-07-01

    There has been rapid progress in our understanding of dry eye pathogenesis, as well as the development of improved diagnostic clinical tests. Various types of dry eye treatment drugs have been developed. This review summarizes the basic and clinical research carried out in the development of diquafosol for ophthalmic use. Diquafosol is a dinucleotide, purinoreceptor P2Y(2) receptor agonist. Basic pharmacological studies have shown that it acts on P2Y(2) receptors at the ocular surface, to promote tear and mucin secretion via elevated intracellular Ca(2+) concentrations. Diquafosol also improves tear and mucin secretion in experimental dry eye models. Based on the results of laboratory experiments, the authors conducted a series of clinical studies in patients with dry eye disease. Diquafosol was effective in the treatment of dry eye disease at an optimal dose of 3% six times a day. In comparison to commercially available 0.1% sodium hyaluronate ophthalmic solution, 3% diquafosol ophthalmic solution showed non-inferiority in improving corneal fluorescein staining scores and superiority in improving keratoconjunctival Rose Bengal staining scores. Diquafosol ophthalmic solution has a novel mechanism of action that is characterized by its stimulatory effects on tear and mucin secretion. This drug has the potential to be effective in patients with tear film instability and short break-up time type of dry eye, which are essential factors in dry eye pathogenesis.

  17. USING EYE TRACKING TO MEASURE ONLINE INTERACTIVITY: A THEORETICAL FRAMEWORK

    Directory of Open Access Journals (Sweden)

    Adriana-Emilia ROBU

    2013-06-01

    Full Text Available Notwithstanding that each and every company, even the sweetshop around the corner has found its way to the Internet, some customers still hesitate to shop online or to shop from one site and ignore the other. In order to build an online effective communication between the participants, one of the most important factors is interactivity. In the last decade it received extensive attention in the marketing literature, but few are the studies which have seen new methods to measure it. Eye tracking technology has been broadly used in the cognitive sciences. The purpose of this study is to investigate the existing literature in order to give insights into the eye tracking methodology when measuring the online interactivity. It also describes the eye tracking technology in general, extracts various examples from the eye tracking research field, with different applications, highlights its importance when analyzing the online consumer behavior, giving examples from various studies and finds the key points of the methodological difficulties. Finally, this work has an important merit for the future studies when taking into consideration the eye tracking technology in the online interactivity research and further, it is relevant for marketers, regarding the enhancement of online interactive interfaces and web or mobile applications.

  18. Organization of eye bank

    International Nuclear Information System (INIS)

    Reddy, S.C.

    1999-01-01

    Comeal transplantation is the only method of combating the blindness due to corneal opacity caused by infections, malnutrition, trauma and hereditary diseases. Comeal blindness is more prevalent in the developing countries. The availability of the donor cornea, trained ophthalmic surgeons and microsurgery facilities are the key factors in restoring vision in-patients with comeal blindness. The eye bank organization is somewhat similar to that of blood bank. The eye bank should be located in a hospital or a medical centre in which a laboratory may be established for the evaluation and storage of donor tissue. The medical director (Ophthalmologist), technician, secretary and public relation officer are the persons who play an important role in the successful organization of eye bank. The function of the eye bank are procurement, assessment, processing, distribution of donor eyes/corneas, training of technicians/doctors, and conducting research related to storage of donor tissue and corneal transplantation. The necessary infrastructure required for the organization of an eye bank include separate accommodation area for the personnel and the laboratory, telephone, computer, refrigerator, laminar air flow hood. Slitlamp, specular microscope, storage media and equipment, instrument for enucleation of donor eyes, and a motor vehicle. The details of responsibilities of the staff of eye bank, source of donor eyes, suitability of donor material, procurement of the donor cornea, tissue assessment, storage and preservation, distribution of donor tissue, and limitation of eye bank will be discussed at the time of presentation

  19. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation

    Directory of Open Access Journals (Sweden)

    Latif Abdul

    2010-01-01

    Full Text Available The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and antiallergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  20. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation

    Directory of Open Access Journals (Sweden)

    Latif Abdul

    2010-03-01

    Full Text Available The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and anti- allergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  1. Management of digital eye strain.

    Science.gov (United States)

    Coles-Brennan, Chantal; Sulley, Anna; Young, Graeme

    2018-05-23

    Digital eye strain, an emerging public health issue, is a condition characterised by visual disturbance and/or ocular discomfort related to the use of digital devices and resulting from a range of stresses on the ocular environment. This review aims to provide an overview of the extensive literature on digital eye strain research with particular reference to the clinical management of symptoms. As many as 90 per cent of digital device users experience symptoms of digital eye strain. Many studies suggest that the following factors are associated with digital eye strain: uncorrected refractive error (including presbyopia), accommodative and vergence anomalies, altered blinking pattern (reduced rate and incomplete blinking), excessive exposure to intense light, closer working distance, and smaller font size. Since a symptom may be caused by one or more factors, a holistic approach should be adopted. The following management strategies have been suggested: (i) appropriate correction of refractive error, including astigmatism and presbyopia; (ii) management of vergence anomalies, with the aim of inducing or leaving a small amount of heterophoria (~1.5 Δ Exo); (iii) blinking exercise/training to maintain normal blinking pattern; (iv) use of lubricating eye drops (artificial tears) to help alleviate dry eye-related symptoms; (v) contact lenses with enhanced comfort, particularly at end-of-day and in challenging environments; (vi) prescription of colour filters in all vision correction options, especially blue light-absorbing filters; and (vii) management of accommodative anomalies. Prevention is the main strategy for management of digital eye strain, which involves: (i) ensuring an ergonomic work environment and practice (through patient education and the implementation of ergonomic workplace policies); and (ii) visual examination and eye care to treat visual disorders. Special consideration is needed for people at a high risk of digital eye strain, such as computer

  2. Advocacy for eye care

    Directory of Open Access Journals (Sweden)

    Thulasiraj D Ravilla

    2012-01-01

    Full Text Available The effectiveness of eye care service delivery is often dependant on how the different stakeholders are aligned. These stakeholders range from the ministries of health who have the capacity to grant government subsidies for eye care, down to the primary healthcare workers who can be enrolled to screen for basic eye diseases. Advocacy is a tool that can help service providers draw the attention of key stakeholders to a particular area of concern. By enlisting the support, endorsement and participation of a wider circle of players, advocacy can help to improve the penetration and effectiveness of the services provided. There are several factors in the external environmental that influence the eye care services - such as the availability of trained manpower, supply of eye care consumables, government rules and regulations. There are several instances where successful advocacy has helped to create an enabling environment for eye care service delivery. Providing eye care services in developing countries requires the support - either for direct patient care or for support services such as producing trained manpower or for research and dissemination. Such support, in the form of financial or other resources, can be garnered through advocacy.

  3. Eye tracking for visual marketing

    NARCIS (Netherlands)

    Wedel, M.; Pieters, R.

    2008-01-01

    We provide the theory of visual attention and eye-movements that serves as a basis for evaluating eye-tracking research and for discussing salient and emerging issues in visual marketing. Motivated from its rising importance in marketing practice and its potential for theoretical contribution, we

  4. Eye cosmetic usage and associated ocular comfort.

    Science.gov (United States)

    Ng, Alison; Evans, Katharine; North, Rachel; Purslow, Christine

    2012-11-01

    Eye cosmetics usage is commonplace and whilst some products such as eyeliner are applied with close proximity to the ocular surface, there is little knowledge of the short- and long-term ocular effects of eye cosmetic formulations. This study aimed to investigate the use of eye cosmetics and identify any relationships between ocular comfort and cosmetic usage. Results were collated from an online survey comprising 23 questions that recorded demographics, Ocular Surface Disease Index (OSDI) score, extent and range of eye cosmetic use and perceived comfort differences with and without eye cosmetics. The 1360 female respondents (median age 25, interquartile range 20-34 years) completed the survey; 83% reported using eye cosmetics regularly (≥ 3 times per week) with mascara being most commonly used. Fifty three per cent used at least three different eye cosmetics products regularly. OSDI scores of cosmetics users were similar to non-users (p = 0.083), but perceived comfort was greater when cosmetics were not used (p cosmetics users (use of products cosmetics were used. Median OSDI scores suggested a trend towards reduced comfort amongst eyeliner users (p = 0.07) although frequency and type of cosmetic products used did not appear to influence OSDI scores. This study shows the use of multiple eye cosmetics is extensive and associated with the perception of ocular discomfort. With such widespread use of these products, more research is required to assess the effect on the ocular surface and tear film, which may be underestimated. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

  5. Randomized, Multicenter, Double-Blind Study of the Safety and Efficacy of 1%D-3-Hydroxybutyrate eye drops for Dry Eye Disease.

    Science.gov (United States)

    Kawakita, Tetsuya; Uchino, Miki; Fukagawa, Kazumi; Yoshino, Kenichi; Shimazaki, Seika; Toda, Ikuko; Tanaka, Mari; Arai, Hiroyuki; Sakatani, Keiko; Hata, Seiichiro; Okano, Takashi; Tsubota, Kazuo

    2016-02-11

    In a previous study, we demonstrated that topical D-beta-hydroxybutyrate ameliorates corneal epithelial erosion and superficial punctate keratopathy in a rat model of dry eye disease. In the current investigation, we performed a prospective, randomized, multicentre, double-blind, placebo-controlled study to assess the safety and efficacy of 1% D-3-hydroxybutyrate eye drops in patients with dry eye disease. A total of 65 patients were randomly assigned to either the placebo group or the 1% D-3-hydroxybutyrate group, and the treatments were administered 6 times a day for 4 weeks. We then evaluated corneal fluorescein staining, corneal and conjunctival rose Bengal staining, tear film break-up time (BUT), Schirmer score, and subjective symptoms. At both 2 and 4 weeks, the corneal rose Bengal score was significantly better in the 1% D-3-hydroxybutyrate group than in the placebo group. Among patients with an initial Schirmer score of ≤5 mm, the corneal fluorescein staining score was significantly better in the 1% D-3-hydroxybutyrate group than in the placebo group at two weeks. Mild ocular symptoms occurred in both groups, and these spontaneously resolved. The present study suggested that 1% D-3-hydroxybutyrate eye drops are safe and effective in treating ocular surface disorders in patients with tear-deficient dry eye disease.

  6. EEG Eye State Identification Using Incremental Attribute Learning with Time-Series Classification

    Directory of Open Access Journals (Sweden)

    Ting Wang

    2014-01-01

    Full Text Available Eye state identification is a kind of common time-series classification problem which is also a hot spot in recent research. Electroencephalography (EEG is widely used in eye state classification to detect human's cognition state. Previous research has validated the feasibility of machine learning and statistical approaches for EEG eye state classification. This paper aims to propose a novel approach for EEG eye state identification using incremental attribute learning (IAL based on neural networks. IAL is a novel machine learning strategy which gradually imports and trains features one by one. Previous studies have verified that such an approach is applicable for solving a number of pattern recognition problems. However, in these previous works, little research on IAL focused on its application to time-series problems. Therefore, it is still unknown whether IAL can be employed to cope with time-series problems like EEG eye state classification. Experimental results in this study demonstrates that, with proper feature extraction and feature ordering, IAL can not only efficiently cope with time-series classification problems, but also exhibit better classification performance in terms of classification error rates in comparison with conventional and some other approaches.

  7. Public Awareness regarding Common Eye Diseases among Saudi Adults in Riyadh City: A Quantitative Study

    Directory of Open Access Journals (Sweden)

    Waleed A. Al Rashed

    2017-01-01

    Full Text Available Aim. The current study aimed to evaluate the knowledge of eye disease and awareness of eye care among the Saudi adults and to explore existing eye-related misconceptions in the community. Methods. A cross-sectional study was conducted in Riyadh city during May and June 2016. A self-administered anonymous online questionnaire was used to explore the most common misconceptions related to eye diseases and eye care. Results. Out of 1000 individuals, only 711 (71.1% participant responses were received. The participants’ acceptable knowledge (score ≥50% was high about the eye problem in diabetes (88.6%, ocular trauma (81.2%, and other general eye diseases (91.3%, whereas low about refractive errors (63%, pediatric eye problems (51.5%, and glaucoma (14.8%. The variation in knowledge about specific ocular morbidities was significant (p<0.001. The majority of participants reported sources of information about the common eye diseases and eye care encountered from the community, internet-based resources, and social media. Conclusions. The majority of the participants had awareness about the common eye diseases, whereas low percentage of participant’s awareness about specific condition of eye diseases. Public eye health awareness should be more focused on social media and the internet to be able to cover the younger individuals of the community.

  8. Associations between subjective happiness and dry eye disease: a new perspective from the Osaka study.

    Science.gov (United States)

    Kawashima, Motoko; Uchino, Miki; Yokoi, Norihiko; Uchino, Yuichi; Dogru, Murat; Komuro, Aoi; Sonomura, Yukiko; Kato, Hiroaki; Kinoshita, Shigeru; Mimura, Masaru; Tsubota, Kazuo

    2015-01-01

    Dry eye disease has become an important health problem. A lack of concordance between self-reported symptoms and the outcome of dry eye examinations has raised questions about dry eye disease. To explore the association between subjective happiness and objective and subjective symptoms of dry eye disease. The study adopted a cross-sectional design. All the employees of a company in Osaka, Japan. 672 Japanese office workers using Visual Display Terminals (age range: 26-64 years). The dry eye measurement tools included the Schirmer test, conjunctivocorneal staining, the tear film break-up time, as well as the administration of a dry eye symptoms questionnaire. Happiness was measured by the Subjective Happiness Scale. Dry eye examination parameters, dry eye symptoms questionnaires, and the Subjective Happiness Scale score. Of the 672 workers, 561 (83.5%) completed the questionnaires and examinations. The mean Subjective Happiness Scale score was 4.91 (SD = 1.01). This score was inversely correlated with the dry eye symptom score (r = -0.188, p happiness was the lowest in the group without objective results, but reported subjective symptoms of dry eyes (p happiness and self-reported symptoms of dry eyes. Findings of this study revealed a new perspective on dry eye disease, including the potential for innovative treatments of a specific population with dry eye disease.

  9. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., Scientific Director David ...

  10. Searching for Chaos Evidence in Eye Movement Signals

    Directory of Open Access Journals (Sweden)

    Katarzyna Harezlak

    2018-01-01

    Full Text Available Most naturally-occurring physical phenomena are examples of nonlinear dynamic systems, the functioning of which attracts many researchers seeking to unveil their nature. The research presented in this paper is aimed at exploring eye movement dynamic features in terms of the existence of chaotic nature. Nonlinear time series analysis methods were used for this purpose. Two time series features were studied: fractal dimension and entropy, by utilising the embedding theory. The methods were applied to the data collected during the experiment with “jumping point” stimulus. Eye movements were registered by means of the Jazz-novo eye tracker. One thousand three hundred and ninety two (1392 time series were defined, based on the horizontal velocity of eye movements registered during imposed, prolonged fixations. In order to conduct detailed analysis of the signal and identify differences contributing to the observed patterns of behaviour in time scale, fractal dimension and entropy were evaluated in various time series intervals. The influence of the noise contained in the data and the impact of the utilized filter on the obtained results were also studied. The low pass filter was used for the purpose of noise reduction with a 50 Hz cut-off frequency, estimated by means of the Fourier transform and all concerned methods were applied to time series before and after noise reduction. These studies provided some premises, which allow perceiving eye movements as observed chaotic data: characteristic of a space-time separation plot, low and non-integer time series dimension, and the time series entropy characteristic for chaotic systems.

  11. 77 FR 63845 - National Eye Institute; Notice of Closed Meetings

    Science.gov (United States)

    2012-10-17

    ... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI-RFA Stem Cell... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300... Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300...

  12. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    OpenAIRE

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical ...

  13. Eye-hand laterality and right thoracic idiopathic scoliosis.

    Science.gov (United States)

    Catanzariti, Jean-François; Guyot, Marc-Alexandre; Agnani, Olivier; Demaille, Samantha; Kolanowski, Elisabeth; Donze, Cécile

    2014-06-01

    The adolescent idiopathic scoliosis (AIS) pathogenesis remains unknown. Certain studies have shown that there is a correlation between manual laterality and scoliotic deviation. A full study of manual laterality needs to be paired with one for visual dominance. With the aim of physiopathological research, we have evaluated the manual and visual laterality in AIS. A retrospective study from prospective data collection is used to evaluate the distribution of eye-hand laterality (homogeneous or crossed) of 65 right thoracic AIS (mean age 14.8 ± 1.8 years; mean Cobb angle: 32.8°) and a control group of 65 sex and age-matched (mean age 14.6 ± 1.8 years). The manual laterality was defined by the modified Edinburgh Handedness Inventory. The evaluation of the visual laterality is done using three tests (kaleidoscope test, hole-in-the-card test, distance-hole-in-the-card test). The group of right thoracic AIS presents a significantly higher frequency of crossed eye-hand laterality (63 %) than the control group (63 vs. 29.2 %; p laterality is "right hand dominant-left eye dominant" (82.9 %). There is no relationship with the Cobb angle. Those with right thoracic AIS show a higher occurrence of crossed eye-hand laterality. This could point physiopathological research of AIS towards functional abnormality of the optic chiasma through underuse of cross visual pathways, and in particular accessory optic pathways. It would be useful to explore this by carrying out research on AISs through neuroimaging and neurofunctional exploration.

  14. Loneliness and hypervigilance to social cues in females: an eye-tracking study.

    Directory of Open Access Journals (Sweden)

    Gerine M A Lodder

    Full Text Available The goal of the present study was to examine whether lonely individuals differ from nonlonely individuals in their overt visual attention to social cues. Previous studies showed that loneliness was related to biased post-attentive processing of social cues (e.g., negative interpretation bias, but research on whether lonely and nonlonely individuals also show differences in an earlier information processing stage (gazing behavior is very limited. A sample of 25 lonely and 25 nonlonely students took part in an eye-tracking study consisting of four tasks. We measured gazing (duration, number of fixations and first fixation at the eyes, nose and mouth region of faces expressing emotions (Task 1, at emotion quadrants (anger, fear, happiness and neutral expression (Task 2, at quadrants with positive and negative social and nonsocial images (Task 3, and at the facial area of actors in video clips with positive and negative content (Task 4. In general, participants tended to gaze most often and longest at areas that conveyed most social information, such as the eye region of the face (T1, and social images (T3. Participants gazed most often and longest at happy faces (T2 in still images, and more often and longer at the facial area in negative than in positive video clips (T4. No differences occurred between lonely and nonlonely participants in their gazing times and frequencies, nor at first fixations at social cues in the four different tasks. Based on this study, we found no evidence that overt visual attention to social cues differs between lonely and nonlonely individuals. This implies that biases in social information processing of lonely individuals may be limited to other phases of social information processing. Alternatively, biased overt attention to social cues may only occur under specific conditions, for specific stimuli or for specific lonely individuals.

  15. An eye tracking study of bloodstain pattern analysts during pattern classification.

    Science.gov (United States)

    Arthur, R M; Hoogenboom, J; Green, R D; Taylor, M C; de Bruin, K G

    2018-05-01

    Bloodstain pattern analysis (BPA) is the forensic discipline concerned with the classification and interpretation of bloodstains and bloodstain patterns at the crime scene. At present, it is unclear exactly which stain or pattern properties and their associated values are most relevant to analysts when classifying a bloodstain pattern. Eye tracking technology has been widely used to investigate human perception and cognition. Its application to forensics, however, is limited. This is the first study to use eye tracking as a tool for gaining access to the mindset of the bloodstain pattern expert. An eye tracking method was used to follow the gaze of 24 bloodstain pattern analysts during an assigned task of classifying a laboratory-generated test bloodstain pattern. With the aid of an automated image-processing methodology, the properties of selected features of the pattern were quantified leading to the delineation of areas of interest (AOIs). Eye tracking data were collected for each AOI and combined with verbal statements made by analysts after the classification task to determine the critical range of values for relevant diagnostic features. Eye-tracking data indicated that there were four main regions of the pattern that analysts were most interested in. Within each region, individual elements or groups of elements that exhibited features associated with directionality, size, colour and shape appeared to capture the most interest of analysts during the classification task. The study showed that the eye movements of trained bloodstain pattern experts and their verbal descriptions of a pattern were well correlated.

  16. Eye tracking a comprehensive guide to methods and measures

    CERN Document Server

    Holmqvist, Kenneth; Andersson, Richard; Dewhurst, Richard; Jarodzka, Halszka; Weijer, Joost van de

    2011-01-01

    We make 3-5 eye movements per second, and these movements are crucial in helping us deal with the vast amounts of information we encounter in our everyday lives. In recent years, thanks to the development of eye tracking technology, there has been a growing interest in monitoring and measuring these movements, with a view to understanding how we attend to and process the visual information we encounter Eye tracking as a research tool is now more accessible than ever, and is growing in popularity amongst researchers from a whole host of different disciplines. Usability analysts, sports scientists, cognitive psychologists, reading researchers, psycholinguists, neurophysiologists, electrical engineers, and others, all have a vested interest in eye tracking for different reasons. The ability to record eye-movements has helped advance our science and led to technological innovations. However, the growth of eye tracking in recent years has also presented a variety of challenges - in particular the issue of how to d...

  17. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  18. About the Eye

    Medline Plus

    Full Text Available ... Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs ... Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and ...

  19. A case-crossover study on transient risk factors of work-related eye injuries.

    Science.gov (United States)

    Chen, S-Y; Fong, P-C; Lin, S-F; Chang, C-H; Chan, C-C

    2009-08-01

    To investigate modifiable risk and preventive factors of work-related eye injuries. A case-crossover study conducted to explore the associations between transient risk factors and work-related eye injuries. Patients seen at seven medical centres in Taiwan with work-related eye injuries over a 4-year period were enrolled in the study. Clinical information was collected from medical charts and detailed information on exposure to eight potentially modifiable factors during the 60 minutes prior to the occurrence of each injury, as well as during the same time interval on the last work day prior to the injury, were obtained using questionnaire surveys. Matched-pair interval analysis was adopted to assess the odds ratios (ORs) for work-related eye injuries given exposure to the eight modifiable factors. A total of 283 subjects were interviewed. Most of these injured workers were young, male, and self-employed or small enterprise workers. The most common injury type was photokeratitis (33.2%), mainly caused by welding (30.4%). The OR for a work-related eye injury was increased with the performance of an unfamiliar task (57.0), operation of a faulty tool or piece of equipment (48.5), distractions (24.0), being rushed (13.0), or fatigued (10.0), and a poor work environment (4.3). Wearing eye protection devices was found to have a significant protective effect on workers who might otherwise have been exposed to eye injuries (OR = 0.4; 95% CI 0.2 to 0.7). Potential modifiable risk and preventive factors for work-related eye injuries were identified using a case-crossover study. This information should be helpful in the development of preventive strategies.

  20. Lateralization for visual processes: eye preference in Campbell's monkeys (Cercopithecus c. campbelli).

    Science.gov (United States)

    Chapelain, Amandine S; Blois-Heulin, Catherine

    2009-01-01

    Brain lateralization has been the matter of extensive research over the last centuries, but it remains an unsolved issue. While hand preferences have been extensively studied, very few studies have investigated laterality of eye use in non-human primates. We examined eye preference in 14 Campbell's monkeys (Cercopithecus c. campbelli). We assessed eye preference to look at a seed placed inside a tube using monocular vision. Eye use was recorded for 100 independent and non-rewarded trials per individual. All of the 14 monkeys showed very strong preferences in the choice of the eye used to look inside the tube (mean preference: 97.6%). Eight subjects preferred the right eye and six subjects preferred the left eye. The results are discussed in light of previous data on eye preference in primates, and compared to data on hand preference from these subjects. Our findings would support the hypothesis for an early emergence of lateralization for perceptual processes compared to manual motor functions.

  1. Radiation protection to the eye and thyroid during diagnostic cerebral angiography: a phantom study.

    LENUS (Irish Health Repository)

    Shortt, C P

    2008-08-01

    We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  2. Radiation protection to the eye and thyroid during diagnostic cerebral angiography : a phantom study

    International Nuclear Information System (INIS)

    Shortt, C. P.; Malone, L.; Thornton, J.; Brennan, P.; Lee, M. J.

    2008-01-01

    Full text: We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  3. Eye Movements When Viewing Advertisements

    Directory of Open Access Journals (Sweden)

    Emily eHiggins

    2014-03-01

    Full Text Available In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads, before turning to a consideration of advertisements in dynamic media (television and the Internet. Finally, we propose topics and methodological approaches that may prove to be useful in future research.

  4. About the Eye

    Medline Plus

    Full Text Available ... Office of the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the ...

  5. Nutrients for the aging eye

    Directory of Open Access Journals (Sweden)

    Rasmussen HM

    2013-06-01

    Full Text Available Helen M Rasmussen,1 Elizabeth J Johnson2 1Educational Studies, Lesley University, Cambridge, MA, USA; 2Carotenoid and Health Laboratory, Jean Mayer US Department of Agriculture Human Nutrition Research Center on Aging at Tufts University, Boston, MA, USA Abstract: The incidence of age-related eye diseases is expected to rise with the aging of the population. Oxidation and inflammation are implicated in the etiology of these diseases. There is evidence that dietary antioxidants and anti-inflammatories may provide benefit in decreasing the risk of age-related eye disease. Nutrients of interest are vitamins C and E, β-carotene, zinc, lutein, zeaxanthin, and the omega-3 fatty acids eicosapentaenoic acid and docosahexaenoic acid. While a recent survey finds that among the baby boomers (45–65 years old, vision is the most important of the five senses, well over half of those surveyed were not aware of the important nutrients that play a key role in eye health. This is evident from a national survey that finds that intake of these key nutrients from dietary sources is below the recommendations or guidelines. Therefore, it is important to educate this population and to create an awareness of the nutrients and foods of particular interest in the prevention of age-related eye disease. Keywords: nutrition, aging, eye health

  6. Clinical characterisation and cytological study of dry eye in patients with autoimmune disease.

    Science.gov (United States)

    Guannan, Huang; Long, Su; Xia, Hua; Dong, Wang; Shaozhen, Zhao

    2018-03-01

    To assess the clinical characteristics and changes in ocular surface cytology of dry eye in patients with systemic autoimmune disease. The case-control study was conducted in the Second Hospital of Tianjin Medical University, Tianjin, China, from February 2016 to January 2017, and comprised systemic autoimmune disease patients and healthy controls. Schirmer's I test, tear breakup time test, and fluorescein staining were performed on all subjects. Both groups were evaluated for dry eye with the current diagnostic criteria. Conjunctival impression cytology and the morphology of epithelial cells were observed in both groups of subjects. Flow cytometry was used to identify the amount of apoptosis. SPSS 15 was used to analyse the data. Each of the two groups had 60(50%) subjects each. The morbidity of dry eye in the control group was 17(28.3%), while it was 31(51.7%) in the patients (pdry eye, the severity level of cells obtained by conjunctival impression sampling was significantly higher in patients than in controls (pdry eye than in patients without dry eye in each group, and among patients with dry eye, the percentage of conjunctival epithelial cells undergoing apoptosis was higher in the patients than in controls (pdry eye in systemic autoimmune disease than in subjects with dry eye in healthy controls.

  7. Eye gaze tracking based on the shape of pupil image

    Science.gov (United States)

    Wang, Rui; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is an important instrument for research in psychology, widely used in attention, visual perception, reading and other fields of research. Because of its potential function in human-computer interaction, the eye gaze tracking has already been a topic of research in many fields over the last decades. Nowadays, with the development of technology, non-intrusive methods are more and more welcomed. In this paper, we will present a method based on the shape of pupil image to estimate the gaze point of human eyes without any other intrusive devices such as a hat, a pair of glasses and so on. After using the ellipse fitting algorithm to deal with the pupil image we get, we can determine the direction of the fixation by the shape of the pupil.The innovative aspect of this method is to utilize the new idea of the shape of the pupil so that we can avoid much complicated algorithm. The performance proposed is very helpful for the study of eye gaze tracking, which just needs one camera without infrared light to know the changes in the shape of the pupil to determine the direction of the eye gazing, no additional condition is required.

  8. Visual Complaints and Eye Problems in Orchestral Musicians.

    Science.gov (United States)

    Beckers, Henny Jm; van Kooten-Noordzij, Marina Aw; de Crom, Ronald Mpc; Schouten, Jan Sag; Webers, Carroll Ab

    2016-09-01

    To study visual complaints and eye diseases among professional and amateur orchestral musicians in the Netherlands. In this observational study, members from professional and amateur symphony or wind orchestras were asked to complete a questionnaire collecting demographic data, musical, medical, and family history, and data on present visual complaints and/or eye diseases. Questions about playing in the orchestra were also asked. Data from 70 professionals and 48 amateurs showed that most musicians needed glasses or contact lenses for playing in the orchestra (61% of the professionals, 63% of the amateurs). A majority (66% of professionals, 71% of amateurs) had visited an ophthalmologist at least once during their lifetime, and 10% of the professionals and 23% of the amateurs were currently under treatment of an ophthalmologist. Visual complaints while playing in the orchestra were quite common and included poor lighting conditions, problems with reading small notes, blurred vision, tired eyes, and itching or burning eyes. Professional musicians especially reported adverse effects of eye complaints encountered in the orchestra for daily life; 35% got tired earlier and 33% felt that they could not adequately perform their tasks in the orchestra. The results show that visual complaints and eye problems probably are quite common among orchestral musicians and therefore warrant further interest and research.

  9. Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data.

    Science.gov (United States)

    Ying, Gui-Shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard

    2017-04-01

    To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field in the elderly. When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI -0.03 to 0.32D, p = 0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, p = 0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller p-values, while analysis of the worse eye provided larger p-values than mixed effects models and marginal models. In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision.

  10. Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeong-sik Seo

    2008-06-01

    Full Text Available Objective : This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results : 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn’t physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn’t eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions : I suggested that Bovis Calculus pharmacopuncture solution didn’t induced eye irritation in rabbits.

  11. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  12. Continuous Auditory Feedback of Eye Movements: An Exploratory Study toward Improving Oculomotor Control

    Directory of Open Access Journals (Sweden)

    Eric O. Boyer

    2017-04-01

    Full Text Available As eye movements are mostly automatic and overtly generated to attain visual goals, individuals have a poor metacognitive knowledge of their own eye movements. We present an exploratory study on the effects of real-time continuous auditory feedback generated by eye movements. We considered both a tracking task and a production task where smooth pursuit eye movements (SPEM can be endogenously generated. In particular, we used a visual paradigm which enables to generate and control SPEM in the absence of a moving visual target. We investigated whether real-time auditory feedback of eye movement dynamics might improve learning in both tasks, through a training protocol over 8 days. The results indicate that real-time sonification of eye movements can actually modify the oculomotor behavior, and reinforce intrinsic oculomotor perception. Nevertheless, large inter-individual differences were observed preventing us from reaching a strong conclusion on sensorimotor learning improvements.

  13. Development of the New Zealand White Rabbit Eye: I. Pre- and Postnatal Development of Eye Tunics.

    Science.gov (United States)

    Abdo, M; Haddad, S; Emam, M

    2017-10-01

    The New Zealand white (NZW) rabbit has been and is right now regularly utilized in ophthalmic surgery evaluation. Inside NZW rabbit eye, the visibility of ocular structures throughout surgical procedure is fantastic. Younger rabbits are used in different ages for the evaluation of ophthalmic surgery. Complete studies of ocular development in the NZW rabbits have not been reported previously. The aim of the present investigation was to describe the major landmarks and the time course of the pre- and post-natal development of the complete eye tunics of the NZW rabbit to give a superb model as well as a fruitful area for further ophthalmological investigations. Serial histological sections of NZW rabbit prenatal (E13-E28) and post-natal (P1-P14) stages were examined, respectively. The eye of the NZW rabbit developed in a similar manner to that of the human and domestic animals eyes; the principal differences were at the time of occurrence of certain developmental events, absence of pigmentation which represent an exploited benefit for ophthalmic surgery, remarkable Bowman's membrane at E25, poor developed ciliary stroma and juvenile retinal layer until P9. In human, the basic morphogenetic processes of the development of eye tunics are completed towards the end of the first half of gestation period. However, the latter represents the beginning stage of the development of eye tunics in the rabbit. Thus, allowing various extensive ophthalmic researches to be performed. © 2017 Blackwell Verlag GmbH.

  14. Research on direct calibration method of eye-to-hand system of robot

    Science.gov (United States)

    Hu, Xiaoping; Xie, Ke; Peng, Tao

    2013-10-01

    In the position-based visual servoing control for robot, the hand-eye calibration is very important because it can affect the control precision of the system. According to the robot with eye-to-hand stereovision system, this paper proposes a direct method of hand-eye calibration. The method utilizes the triangle measuring principle to solve the coordinates in the camera coordinate system of scene point. It calculates the estimated coordinates by the hand-eye calibration equation set which indicates the transformational relation from the robot to the camera coordinate system, and then uses the error of actual and estimated coordinates to establish the objective function. Finally the method substitutes the parameters into the function repeatedly until it converged to optimize the result. The related experiment compared the measured coordinates with the actual coordinates, shows the efficiency and the precision of it.

  15. Generating and Describing Affective Eye Behaviors

    Science.gov (United States)

    Mao, Xia; Li, Zheng

    The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.

  16. The effect of human image in B2C website design: an eye-tracking study

    Science.gov (United States)

    Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo

    2014-09-01

    On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.

  17. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  18. The Eyes Are the Windows to the Mind: Direct Eye Gaze Triggers the Ascription of Others' Minds.

    Science.gov (United States)

    Khalid, Saara; Deska, Jason C; Hugenberg, Kurt

    2016-12-01

    Eye gaze is a potent source of social information with direct eye gaze signaling the desire to approach and averted eye gaze signaling avoidance. In the current work, we proposed that eye gaze signals whether or not to impute minds into others. Across four studies, we manipulated targets' eye gaze (i.e., direct vs. averted eye gaze) and measured explicit mind ascriptions (Study 1a, Study 1b, and Study 2) and beliefs about the likelihood of targets having mind (Study 3). In all four studies, we find novel evidence that the ascription of sophisticated humanlike minds to others is signaled by the display of direct eye gaze relative to averted eye gaze. Moreover, we provide evidence suggesting that this differential mentalization is due, at least in part, to beliefs that direct gaze targets are more likely to instigate social interaction. In short, eye contact triggers mind perception. © 2016 by the Society for Personality and Social Psychology, Inc.

  19. The top 100 papers in dry eye - A bibliometric analysis.

    Science.gov (United States)

    Schargus, Marc; Kromer, Robert; Druchkiv, Vasily; Frings, Andreas

    2018-01-01

    Citation analysis represents one of the best currently available methods for quantifying the impact of articles. Bibliometric studies list the ''best sellers'' in a single field of interest. The purpose of the present study was to identify and analyze the most frequently cited papers in dry eye research that may be of high interest for researchers and clinicians. We reviewed the database of the Institute for Scientific Information to identify articles published from 1900 to September 2016. All dry eye articles published in 59 ophthalmology journals were identified. The top 100 articles were selected for further analysis of authorship, source journal, number of citations, citation rate, geographic origin, article type, and level of evidence. The 100 most-cited articles were published between 1983 and 2011, with most of them in the 2000s. The number of citations per article ranged from 96 to 610, and was greatest for articles published in the 2000s. Each of these articles was published in one of 15 journals. Most articles represented Level-III evidence, followed by Levels II and I. The present study focusing on dry eye research revealed that 55% of the most-cited articles came from the U.S. and 18% from Japan. Diagnostics and therapy were the areas of focus of most of the clinical articles; 13% of the most cited papers were review articles. This analysis provides researchers and clinicians with a detailed overview on the most cited dry eye papers over the past decades. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Prophylactic treatment of the fellow eye of patients with retinal detachment: a retrospective study.

    Science.gov (United States)

    Avitabile, Teresio; Bonfiglio, Vincenza; Reibaldi, Michele; Torrisi, Benedetto; Reibaldi, Alfredo

    2004-03-01

    Controversy exists over the prophylactic treatment of predisposing lesions to prevent retinal detachment. Seven hundred sixty consecutive phakic fellow eyes with rhegmatogenous retinal detachment in the first eye were examined by the same vitreoretinal surgeon before detachment surgery and for a follow-up period ranging from 1 to 72 months, with a mean of 36 months. During this period, in 305 fellow eyes (40.1%) predisposing retinal lesions were present and prophylactic treatments (photocoagulation, cryotherapy or scleral buckle) were performed independently of vitreous status. The results were then compared with the incidence of bilateral RD without prophylaxis reported in Folk and Burton's study of 1982; the two study's data were well matched and showed no significant difference in regards to age, sex, incidence myopia > or =-2.5 and incidence of lattice degeneration. The objective was to investigate whether or not prophylactic treatment is able to avert retinal detachment in the fellow eye. The age of the patients with peripheral retinal lesions was correlated inversely with the presence of myopia. Nine eyes out of 305 eyes treated (2.9%) developed a retinal detachment, reducing the rate of bilateral retinal detachment to 1.2% (9 eyes out of 760). This incidence of bilaterality (1.2%) was lower than the incidence of retinal detachment in fellow eyes not prophylactically treated as reported in the literature, and there exists a highly statistically significant difference between this study's data of 1.2% after prophylaxis and a 13.4% rate of bilaterality as reported by Folk without prophylaxis (P=0.0000).

  1. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  2. Systemic medication and intraocular pressure in a British population: the EPIC-Norfolk Eye Study.

    Science.gov (United States)

    Khawaja, Anthony P; Chan, Michelle P Y; Broadway, David C; Garway-Heath, David F; Luben, Robert; Yip, Jennifer L Y; Hayat, Shabina; Wareham, Nicholas J; Khaw, Kay-Tee; Foster, Paul J

    2014-08-01

    To determine the association between systemic medication use and intraocular pressure (IOP) in a population of older British men and women. Population-based, cross-sectional study. We included 7093 participants from the European Prospective Investigation into Cancer-Norfolk Eye Study. Exclusion criteria were a history of glaucoma therapy (medical, laser, or surgical), IOP asymmetry between eyes of >5 mmHg, and missing data for any covariables. The mean age of participants was 68 years (range, 48-92) and 56% were women. We measured IOP using the Ocular Response Analyzer. Three readings were taken per eye and the best signal value of the Goldmann-correlated IOP value considered. Participants were asked to bring all their medications and related documentation to the health examination, and these were recorded by the research nurse using an electronic case record form. The medication classes examined were angiotensin-converting enzyme inhibitors, angiotensin-receptor blockers, α-blockers, β-blockers, calcium channel blockers, diuretics, nitrates, statins, insulin, biguanides, sulfonylureas, aspirin, and other nonsteroidal anti-inflammatory drugs. We examined associations between medication use and IOP using multivariable linear regression models adjusted for age, sex, and body mass index. Models containing diabetic medication were further adjusted for glycosylated hemoglobin levels. Mean IOP of the right and left eyes. Use of systemic β-blockers (-0.92 mmHg; 95% CI, -1.19, -0.65; Pnitrates (-0.63 mmHg; 95% CI, -1.12, -0.14; P = 0.011) were independently associated with lower IOP. The observed associations between statin or aspirin use with IOP were no longer significant after adjustment for β-blocker use. This is the first population-based study to demonstrate and quantify clinically significant differences in IOP among participants using systemic β-blockers or nitrates. Lower IOP observed in participants using statins or aspirin was explained by concurrent

  3. Clinical study of 3g/L sodium hyaluronate eye drops with bromhexine hydrochloride tablets for dry eye

    Directory of Open Access Journals (Sweden)

    Hui-Qun Xu

    2018-04-01

    Full Text Available AIM:To investigate the clinical efficacy of 3g/L sodium hyaluronate eye drops combined with bromhexine hydrochloride tablets on the treatment of dry eye. METHODS:Totally 200 patients with dry eye were randomly divided into the control group(n=100and observation group(n=100. Patients in two groups were given 3g/L sodium hyaluronate eye drops and physiotherapy. On the basis of this, the observation group were treated with bromhexine hydrochloride tablets. The inflammatory factors(IL-6, IL-10, TNF-α and IL-1βlevels and ocular symptom scores(OSDI, BUT, SⅠt, FLin the two groups were compared between before and after treatment. And the clinical efficacy and adverse reactions were evaluated. RESULTS: After treatment, the IL-6, IL-10, TNF-α, IL-1β, OSDI and FL scores in two groups were significantly lower than those before treatment, and BUT and SⅠt were significantly higher than those before treatment. Moreover, the improvement degree of the above indexes in the observation group were better than those in the control group, showing statistically significant difference(Pχ2=5.531, P=0.019, but there was no significant difference in the incidence of adverse reactions between the two groups(χ2=0.307, P=0.579. CONCLUSION:As for the patients with dry eye, the combination of 3g/L sodium hyaluronate eye drops with bromhexine hydrochloride tablets can significantly decrease the level of inflammatory factors, improve the eye symptoms and the clinical total efficiency, without increasing treatment-related adverse effects.

  4. Singapore Indian Eye Study-2: methodology and impact of migration on systemic and eye outcomes.

    Science.gov (United States)

    Sabanayagam, Charumathi; Yip, Wanfen; Gupta, Preeti; Mohd Abdul, Riswana Bb; Lamoureux, Ecosse; Kumari, Neelam; Cheung, Gemmy Cm; Cheung, Carol Y; Wang, Jie Jin; Cheng, Ching-Yu; Wong, Tien Yin

    2017-11-01

    Asian Indians are the fastest growing migration groups in the world. Studies evaluating the impact of migration on disease outcomes in this population are rare. We describe the methodology of the Singapore Indian Eye Study-2 (SINDI-2) aimed to evaluate the impact of migration status on diabetic retinopathy and other major age-related eye diseases in Asian Indians living in an urban environment. Population-based cohort study. A total of 2200 adults had participated in baseline SINDI (2007-2009, mean age [range] = 57.8 [42.7-84.1] years) and SINDI-2 (2013-2015, 56.5 [48.4-90.2] years). Participants were classified as 'first generation' if they were Indian residents born outside of Singapore and as 'second-generation' immigrants (59.7% in SINDI vs. 63.6% in SINDI-2) if they were born in Singapore. Response rate, participant characteristics and prevalence of systemic diseases were stratified by migration status. Of the 2914 eligible SINDI participants invited to participate, 2200 participated in SINDI-2 (response rate of 75.2%). In both SINDI and SINDI-2, compared with first-generation immigrants, second-generation immigrants were younger, less likely to have income <1000 SGD, had lower levels of pulse pressure, higher levels of high-density lipoprotein cholesterol, had lower prevalence of hypertension and chronic kidney disease and had higher prevalence of current smoking and obesity (all P < 0.05). In both SINDI and SINDI-2, second-generation immigrants had lower prevalence of cardiovascular risk factors except smoking and obesity compared with first-generation immigrants. The final report will confirm if these differences between generations are evident with regard to eye diseases. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  5. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  6. About the Eye

    Medline Plus

    Full Text Available ... Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  7. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  8. A cross-sectional study of pediatric eye care perceptions in Ghana, Honduras, and India.

    Science.gov (United States)

    Ramai, Daryl; Elliott, Ryan; Goldin, Shoshanna; Pulisetty, Tejas

    2015-06-01

    Of the more than 1.4 million blind children worldwide, 75% live in developing countries. To reduce the prevalence of childhood blindness and associated diseases, attention is given to understanding the perceptions and level of awareness held by caregivers. This understanding can enable tailored health programs to reduce the global prevalence of blindness with increased efficiency. This study, which took place in Ghana, Honduras, and India, found that 95% of caregivers believed in the importance of eye exams for children, yet 66% of caregivers said that none of their children had ever received an eye exam. Participants' major reasons for not bringing their children included the belief that their child had no eye problems along with similar and unique socio-economic barriers. Further information was gained through the use of a five-question test on basic child eye care symptoms, which showed that out of the three country locations, the studied population in India had the least understanding about pediatric eye symptoms. Further analysis revealed significant gaps in understanding of general eye health while detected knowledge barriers provide evidence that fundamental misconceptions appear to be inhibiting caregivers' competence in facilitating their children's eye health. Copyright © 2014 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  9. About the Eye

    Medline Plus

    Full Text Available ... Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research ... iris adjusts the size of the pupil and controls the amount of light that can enter the ...

  10. About the Eye

    Medline Plus

    Full Text Available ... Campus Mission Statement As part of the federal government’s National Institutes of Health (NIH), the National Eye ... Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science ...

  11. A Case-Control Study on the Oxidative Balance of 50% Autologous Serum Eye Drops

    Directory of Open Access Journals (Sweden)

    Patrícia Ioschpe Gus

    2016-01-01

    Full Text Available Importance. Autologous serum (AS eye drops are recommended for severe dry eye in patients with ocular surface disease. No description of the antioxidant balance of AS eye drops has been reported in the literature. Objective. This study sought to evaluate the total reactive antioxidant potential (TRAP and concentration of reactive oxygen species (ROS in samples of 50% AS eye drops and their correlations with the demographic characteristics and lifestyle habits of patients with ocular surface disease and healthy controls. Design. This was a case-control study with a 3-month follow-up period. Participants. 16 patients with severe dry eye disease of different etiologies and 17 healthy controls matched by age, gender, and race were included. Results. TRAP and ROS were detected at all evaluated times. There were no differences in the mean ROS (p=0.429 or TRAP (p=0.475 levels between cases and controls. No statistically significant differences in the concentrations of ROS or TRAPs were found at 0, 15, or 30 days (p for ROS = 0.087 and p for TRAP = 0.93. Neither the demographic characteristics nor the lifestyle habits were correlated with the oxidative balance of the 50% AS eye drops. Conclusions and Relevance. Both fresh and frozen 50% AS eye drops present antioxidant capacities and ROS in an apparently stable balance. Moreover, patients with ocular surface disease and normal controls produce equivalent AS eye drops in terms of oxidative properties.

  12. About the Eye

    Medline Plus

    Full Text Available ... Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  13. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  14. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  15. Objective eye-gaze behaviour during face-to-face communication with proficient alaryngeal speakers: a preliminary study.

    Science.gov (United States)

    Evitts, Paul; Gallop, Robert

    2011-01-01

    There is a large body of research demonstrating the impact of visual information on speaker intelligibility in both normal and disordered speaker populations. However, there is minimal information on which specific visual features listeners find salient during conversational discourse. To investigate listeners' eye-gaze behaviour during face-to-face conversation with normal, laryngeal and proficient alaryngeal speakers. Sixty participants individually participated in a 10-min conversation with one of four speakers (typical laryngeal, tracheoesophageal, oesophageal, electrolaryngeal; 15 participants randomly assigned to one mode of speech). All speakers were > 85% intelligible and were judged to be 'proficient' by two certified speech-language pathologists. Participants were fitted with a head-mounted eye-gaze tracking device (Mobile Eye, ASL) that calculated the region of interest and mean duration of eye-gaze. Self-reported gaze behaviour was also obtained following the conversation using a 10 cm visual analogue scale. While listening, participants viewed the lower facial region of the oesophageal speaker more than the normal or tracheoesophageal speaker. Results of non-hierarchical cluster analyses showed that while listening, the pattern of eye-gaze was predominantly directed at the lower face of the oesophageal and electrolaryngeal speaker and more evenly dispersed among the background, lower face, and eyes of the normal and tracheoesophageal speakers. Finally, results show a low correlation between self-reported eye-gaze behaviour and objective regions of interest data. Overall, results suggest similar eye-gaze behaviour when healthy controls converse with normal and tracheoesophageal speakers and that participants had significantly different eye-gaze patterns when conversing with an oesophageal speaker. Results are discussed in terms of existing eye-gaze data and its potential implications on auditory-visual speech perception. © 2011 Royal College of Speech

  16. Eye-size variability in deep-sea lanternfishes (Myctophidae): an ecological and phylogenetic study.

    Science.gov (United States)

    de Busserolles, Fanny; Fitzpatrick, John L; Paxton, John R; Marshall, N Justin; Collin, Shaun P

    2013-01-01

    One of the most common visual adaptations seen in the mesopelagic zone (200-1000 m), where the amount of light diminishes exponentially with depth and where bioluminescent organisms predominate, is the enlargement of the eye and pupil area. However, it remains unclear how eye size is influenced by depth, other environmental conditions and phylogeny. In this study, we determine the factors influencing variability in eye size and assess whether this variability is explained by ecological differences in habitat and lifestyle within a family of mesopelagic fishes characterized by broad intra- and interspecific variance in depth range and luminous patterns. We focus our study on the lanternfish family (Myctophidae) and hypothesise that lanternfishes with a deeper distribution and/or a reduction of bioluminescent emissions have smaller eyes and that ecological factors rather than phylogenetic relationships will drive the evolution of the visual system. Eye diameter and standard length were measured in 237 individuals from 61 species of lanternfishes representing all the recognised tribes within the family in addition to compiling an ecological dataset including depth distribution during night and day and the location and sexual dimorphism of luminous organs. Hypotheses were tested by investigating the relationship between the relative size of the eye (corrected for body size) and variations in depth and/or patterns of luminous-organs using phylogenetic comparative analyses. Results show a great variability in relative eye size within the Myctophidae at all taxonomic levels (from subfamily to genus), suggesting that this character may have evolved several times. However, variability in eye size within the family could not be explained by any of our ecological variables (bioluminescence and depth patterns), and appears to be driven solely by phylogenetic relationships.

  17. Eye safe laser range finders

    International Nuclear Information System (INIS)

    Snir, M.; Margaliot, M.; Amitzi, A.

    2004-01-01

    During the 1970's, Ruby (Q switched) laser based range finders with a wavelength of 694nm were first used. These lasers operated in a pulse mode within the visible light range and produced a risk for the eye retina. The laser beam striking the macula could damage the eye and might cause blindness. Over the years, Nd:YAG (Q switched) lasers were developed (operating at 1064nm) for range finding and designation uses. The wavelength of these lasers, operating in the near Infra-Red range (invisible), is also focused tightly on the retina. The human eye does not respond to the invisible light so there is no natural protection (eye blink reflex) as in the visible light. The operation of these lasers worldwide, especially when the laser beam is exposed, causes occasional eye accidents. Another risk is stemming from the use of observation systems with a high optical gain, in the laser operation areas, which enlarge the range of risk quite significantly. Therefore, research and development efforts were invested in order to introduce eye safe lasers. One of the solutions for this problem is presented in following document

  18. Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.

    Science.gov (United States)

    Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr

    2014-03-01

    In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. About the Eye

    Medline Plus

    Full Text Available ... of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., ... David M. Schneeweis, Ph.D., Deputy Scientific Director Office of the Clinical Director Brian P. Brooks, M. ...

  20. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is ...

  1. Integrating eye tracking in virtual reality for stroke rehabilitation

    OpenAIRE

    Alves, Júlio Miguel Gomes Rebelo

    2014-01-01

    This thesis reports on research done for the integration of eye tracking technology into virtual reality environments, with the goal of using it in rehabilitation of patients who suffered from stroke. For the last few years, eye tracking has been a focus on medical research, used as an assistive tool  to help people with disabilities interact with new technologies  and as an assessment tool  to track the eye gaze during computer interactions. However, tracking more complex gaze behavio...

  2. Eye-movements and ongoing task processing.

    Science.gov (United States)

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory.

  3. A generalised porous medium approach to study thermo-fluid dynamics in human eyes.

    Science.gov (United States)

    Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal

    2018-03-22

    The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.

  4. How visual search relates to visual diagnostic performance : a narrative systematic review of eye-tracking research in radiology

    NARCIS (Netherlands)

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; ten Cate, Olle

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review

  5. Neuroimaging in the Diagnostic Evaluation of Eye Pain.

    Science.gov (United States)

    Szatmáry, Gabriella

    2016-09-01

    Ocular or eye pain is a frequent complaint encountered not only by eye care providers but neurologists. Isolated eye pain is non-specific and non-localizing; therefore, it poses significant differential diagnostic problems. A wide range of neurologic and ophthalmic disorders may cause pain in, around, or behind the eye. These include ocular and orbital diseases and primary and secondary headaches. In patients presenting with an isolated and chronic eye pain, neuroimaging is usually normal. However, at the beginning of a disease process or in low-grade disease, the eye may appear "quiet," misleading a provider lacking familiarity with underlying disorders and high index of clinical suspicion. Delayed diagnosis of some neuro-ophthalmic causes of eye pain could result in significant neurologic and ophthalmic morbidity, conceivably even mortality. This article reviews some recent advances in imaging of the eye, the orbit, and the brain, as well as research in which neuroimaging has advanced the discovery of the underlying pathophysiology and the complex differential diagnosis of eye pain.

  6. Are better eye movements an advantage in ball games? A study of prosaccadic and antisaccadic eye movements

    NARCIS (Netherlands)

    Lenoir, M.; Crevits, L.; Goethals, M.; Wildenbeest, J.; Musch, E.

    2000-01-01

    The aim of this study was to compare prosaccadic and antisaccadic eye movements of experts in ball sports and controls. In the prosaccadic and antisaccadic task, subjects made saccades respectively towards and away from a suddenly appearing stimulus. By means of infrared-oculography, we compared

  7. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  8. Addendum report of the JHPS expert committee on radiation protection of the lens of the eye (1). Eye lens dosimetry R and D, and radiation management and estimated eye-lens exposure for workers in Japanese nuclear power plants

    International Nuclear Information System (INIS)

    Akahane, Keiichi; Tatsuzaki, Hideo; Iimoto, Takeshi; Ichiji, Takeshi; Hamada, Nobuyuki; Iwai, Satoshi; Ohguchi, Hiroyuki; Ohno, Kazuko; Katoh, Masahiro; Kurosawa, Tadahiro; Kawaura, Chiyo; Tsujimura, Norio; Hayashida, Toshiyuki; Hotta, Yutaka; Yamasaki, Tadashi; Yokoyama, Sumi

    2015-01-01

    The Expert Committee on Radiation Protection of the Lens of the Eye was established under the Japan Health Physics Society in April, 2013 (completed, March, 2015). The Committee looked at new/revised documents and standards related to the eye lens published by international organizations such as the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). The Committee also examined recent and previous studies related to eye-lens radiation exposure and dosimetry in Japan. These findings were published in this journal as the Interim Report of the Committee. Since then, the Committee expanded its activity to give an overview the current progress of eye-lens dosimetry R and D at the National Institute of Advanced Industrial Science and Technology, along with research related to radiation management and estimated eye-lens exposure of Japanese nuclear-power-plant workers (including those at Fukushima Daiichi Nuclear Power Plant) for publishing an addendum Committee report. These additional findings are reported here. (author)

  9. Sorption studies of uranium in sediment-groundwater systems from the natural analogue sites of Needle's Eye and Broubster

    International Nuclear Information System (INIS)

    Higgo, J.J.; Falck, W.E.; Hooker, P.J.

    1990-01-01

    This report describes the results of sorption experiments designed to provide essential data for migration modelling. Sorption of 233 U from natural ground-water onto peat from Broubster and silt from Needle's Eye was studied under atmospheric conditions and different pH regimes. The temperature was maintained at 10 0 C and, in the case of Needle's Eye silt, the kinetics of sorption were followed. The results were analyzed in conjunction with speciation modelling in an attempt to understand the sorption mechanisms and to extrapolate the findings to cover the range of conditions likely to be met in the field. This work is part of the CEC project Mirage - Second phase, research area 'Natural analogues'

  10. Social attention in ASD: A review and meta-analysis of eye-tracking studies.

    Science.gov (United States)

    Chita-Tegmark, Meia

    2016-01-01

    Determining whether social attention is reduced in Autism Spectrum Disorder (ASD) and what factors influence social attention is important to our theoretical understanding of developmental trajectories of ASD and to designing targeted interventions for ASD. This meta-analysis examines data from 38 articles that used eye-tracking methods to compare individuals with ASD and TD controls. In this paper, the impact of eight factors on the size of the effect for the difference in social attention between these two groups are evaluated: age, non-verbal IQ matching, verbal IQ matching, motion, social content, ecological validity, audio input and attention bids. Results show that individuals with ASD spend less time attending to social stimuli than typically developing (TD) controls, with a mean effect size of 0.55. Social attention in ASD was most impacted when stimuli had a high social content (showed more than one person). This meta-analysis provides an opportunity to survey the eye-tracking research on social attention in ASD and to outline potential future research directions, more specifically research of social attention in the context of stimuli with high social content. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. More to it than meets the eye: how eye movements can elucidate the development of episodic memory.

    Science.gov (United States)

    Pathman, Thanujeni; Ghetti, Simona

    2016-07-01

    The ability to recognise past events along with the contexts in which they occurred is a hallmark of episodic memory, a critical capacity. Eye movements have been shown to track veridical memory for the associations between events and their contexts (relational binding). Such eye-movement effects emerge several seconds before, or in the absence of, explicit response, and are linked to the integrity and function of the hippocampus. Drawing from research from infancy through late childhood, and by comparing to investigations from typical adults, patient populations, and animal models, it seems increasingly clear that eye movements reflect item-item, item-temporal, and item-spatial associations in developmental populations. We analyse this line of work, identify missing pieces in the literature and outline future avenues of research, in order to help elucidate the development of episodic memory.

  12. Eye contact perception in the West and East: a cross-cultural study.

    Directory of Open Access Journals (Sweden)

    Shota Uono

    Full Text Available This study investigated whether eye contact perception differs in people with different cultural backgrounds. Finnish (European and Japanese (East Asian participants were asked to determine whether Finnish and Japanese neutral faces with various gaze directions were looking at them. Further, participants rated the face stimuli for emotion and other affect-related dimensions. The results indicated that Finnish viewers had a smaller bias toward judging slightly averted gazes as directed at them when judging Finnish rather than Japanese faces, while the bias of Japanese viewers did not differ between faces from their own and other cultural backgrounds. This may be explained by Westerners experiencing more eye contact in their daily life leading to larger visual experience of gaze perception generally, and to more accurate perception of eye contact with people from their own cultural background particularly. The results also revealed cultural differences in the perception of emotion from neutral faces that could also contribute to the bias in eye contact perception.

  13. Eye contact perception in the West and East: a cross-cultural study.

    Science.gov (United States)

    Uono, Shota; Hietanen, Jari K

    2015-01-01

    This study investigated whether eye contact perception differs in people with different cultural backgrounds. Finnish (European) and Japanese (East Asian) participants were asked to determine whether Finnish and Japanese neutral faces with various gaze directions were looking at them. Further, participants rated the face stimuli for emotion and other affect-related dimensions. The results indicated that Finnish viewers had a smaller bias toward judging slightly averted gazes as directed at them when judging Finnish rather than Japanese faces, while the bias of Japanese viewers did not differ between faces from their own and other cultural backgrounds. This may be explained by Westerners experiencing more eye contact in their daily life leading to larger visual experience of gaze perception generally, and to more accurate perception of eye contact with people from their own cultural background particularly. The results also revealed cultural differences in the perception of emotion from neutral faces that could also contribute to the bias in eye contact perception.

  14. Intact unconscious processing of eye contact in schizophrenia

    Directory of Open Access Journals (Sweden)

    Kiley Seymour

    2016-03-01

    Full Text Available The perception of eye gaze is crucial for social interaction, providing essential information about another person’s goals, intentions, and focus of attention. People with schizophrenia suffer a wide range of social cognitive deficits, including abnormalities in eye gaze perception. For instance, patients have shown an increased bias to misjudge averted gaze as being directed toward them. In this study we probed early unconscious mechanisms of gaze processing in schizophrenia using a technique known as continuous flash suppression. Previous research using this technique to render faces with direct and averted gaze initially invisible reveals that direct eye contact gains privileged access to conscious awareness in healthy adults. We found that patients, as with healthy control subjects, showed the same effect: faces with direct eye gaze became visible significantly faster than faces with averted gaze. This suggests that early unconscious processing of eye gaze is intact in schizophrenia and implies that any misjudgments of gaze direction must manifest at a later conscious stage of gaze processing where deficits and/or biases in attributing mental states to gaze and/or beliefs about being watched may play a role.

  15. Annual direct cost of dry eye in Japan

    Directory of Open Access Journals (Sweden)

    Mizuno Y

    2012-05-01

    Full Text Available Yoshinobu Mizuno, Masakazu Yamada, Chika ShigeyasuDivision for Vision Research, National Institute of Sensory Organs, National Tokyo Medical Center, Tokyo, JapanOn behalf of The Dry Eye Survey Group, National Hospital Organization of JapanBackground: This study was performed to estimate the annual direct cost incurred by dry eye patients, which includes expenses for treatment and drugs, as well as the cost of punctal plugs.Methods: The study group consisted of 118 dry eye patients aged 20 years or older who visited any of the 15 medical care facilities that participated in this prospective cohort dry eye study. We estimated annual direct costs from outpatient medical records and survey questionnaires obtained from patients. Results: Of the total patients enrolled, 10 were men and 108 women, and their average age was 64.1 ± 11.2 years. The number of hospital visits made by patients was 5.8 ± 3.6 per year. Among those who used ophthalmic solutions, the numbers of bottles used per year were as follows: 32.1 ± 20.8 bottles of hyaluronic acid ophthalmic solution (87 patients, 53.1 ± 42.2 bottles of artificial tears (40 patients, and 33.2 ± 23.2 bottles of over-the-counter eyedrops (15 patients. In patients with punctal plugs, 4.1 ± 3.9 plugs were used annually. The annual drug cost was 32,000 ± 21,675 Japanese yen (323 ± 219 US dollars. The clinical cost was 16,318 ± 9961 Japanese yen (165 ± 101 US dollars. The total direct costs including punctal plug treatment amounted to 52,467 ± 38,052 Japanese yen (530 ± 384 US dollars. Conclusion: Although treatment modalities for dry eye in Japan were different from those in the US and in European countries, the direct cost of dry eye patients in Japan was comparable with that reported in those countries. Considering the high prevalence of dry eye, the direct cost of this chronic condition may be significant.Keywords: burden of disease, cost, dry eye, eyedrops, quality of life

  16. The technology study on irradiation sterilization of the eye health care paste

    International Nuclear Information System (INIS)

    Yang Mingcheng; Zhu Jun; Zhao Huidong; Song Weidong; Zhang Hongna; Li Kunhao

    2009-01-01

    The effect of radiation on appearance,color and active ingredients of products has been studied in irradiation sterilization of eye healthy care paste by use of 60 Co γ-rays. The results show that irradiation is very effective on killing the microorganisms in eye healthy care paste, and the D 10 of the aerobic bacterial count is determined to be 3.16kGy. The process adopts the irradiation static stacking mode, and the suitable absorbed dose has been selected to be 7-8kGy. It has been found that irradiation with 7-8kGy does not affect appearance, color and active ingredients of the eye healthy care paste. (authors)

  17. Results of a Multicenter, Randomized, Double-Masked, Placebo-Controlled Clinical Study of the Efficacy and Safety of Visomitin Eye Drops in Patients with Dry Eye Syndrome.

    Science.gov (United States)

    Brzheskiy, Vladimir V; Efimova, Elena L; Vorontsova, Tatiana N; Alekseev, Vladimir N; Gusarevich, Olga G; Shaidurova, Ksenia N; Ryabtseva, Alla A; Andryukhina, Olga M; Kamenskikh, Tatiana G; Sumarokova, Elena S; Miljudin, Eugeny S; Egorov, Eugeny A; Lebedev, Oleg I; Surov, Alexander V; Korol, Andrii R; Nasinnyk, Illia O; Bezditko, Pavel A; Muzhychuk, Olena P; Vygodin, Vladimir A; Yani, Elena V; Savchenko, Alla Y; Karger, Elena M; Fedorkin, Oleg N; Mironov, Alexander N; Ostapenko, Victoria; Popeko, Natalia A; Skulachev, Vladimir P; Skulachev, Maxim V

    2015-12-01

    This article presents the results of an international, multicenter, randomized, double-masked, placebo-controlled clinical study of Visomitin (Mitotech LLC, Moscow, Russian Federation) eye drops in patients with dry eye syndrome (DES). Visomitin is the first registered (in Russia) drug with a mitochondria-targeted antioxidant (SkQ1) as the active ingredient. In this multicenter (10 sites) study of 240 subjects with DES, study drug (Visomitin or placebo) was self-administered three times daily (TID) for 6 weeks, followed by a 6-week follow-up period. Seven in-office study visits occurred every 2 weeks during both the treatment and follow-up periods. Efficacy measures included Schirmer's test, tear break-up time, fluorescein staining, meniscus height, and visual acuity. Safety measures included adverse events, slit lamp biomicroscopy, tonometry, blood pressure, and heart rate. Tolerability was also evaluated. This clinical study showed the effectiveness of Visomitin eye drops in the treatment of signs and symptoms of DES compared with placebo. The study showed that a 6-week course of TID topical instillation of Visomitin significantly improved the functional state of the cornea; Visomitin increased tear film stability and reduced corneal damage. Significant reduction of dry eye symptoms (such as dryness, burning, grittiness, and blurred vision) was also observed. Based on the results of this study, Visomitin is effective and safe for use in eye patients with DES for protection from corneal damage. Mitotech LLC.

  18. Inter-eye comparison of retinal oximetry and vessel caliber between eyes with asymmetrical glaucoma severity in different glaucoma subtypes

    Directory of Open Access Journals (Sweden)

    Cheng CS

    2016-07-01

    Full Text Available Clarissa Shu Ming Cheng,1,2 Yi Fang Lee,2 Charles Ong,3 Zhu Li Yap,2 Andrew Tsai,2 Aditi Mohla,2 Monisha E Nongpiur,4 Tin Aung,2,4 Shamira A Perera2,4 1Department of Ophthalmology, Tan Tock Seng Hospital, 2Department of Ophthalmology, Singapore National Eye Centre, 3Yong Loo Lin School of Medicine, National University of Singapore, 4Singapore Eye Research Institute, Singapore National Eye Centre, Singapore Background: To compare retinal vessel oxygenation and vessel caliber in primary angle-closure glaucoma (PACG, primary open-angle glaucoma (POAG, normal-tension glaucoma (NTG, and normal controls, as well as between eyes of asymmetrical glaucoma severity.Methods: This was a prospective, cross-sectional study. The 159 subjects (PACG, n=39; POAG, n=41; NTG, n=41; normal controls, n=38 underwent retinal oxygen saturation measurements using the Oxymap T1 Retinal Oximeter, optical coherence tomography, and Humphrey visual field testing. Retinal oxygen saturation and vessel diameter were compared between the glaucoma groups and normal controls, as well as between eyes of asymmetrical glaucoma severity. Kruskal–Wallis test was performed for comparison among different subtypes of glaucoma. Wilcoxon signed-rank test was used to compare the inter-eye differences.Results: Compared to normal controls, arteriolar oxygen saturation was increased in PACG eyes (P=0.048 but not in POAG or NTG eyes. There were no significant differences in oxygen saturation in venules or arteriovenous (AV difference in all three glaucoma groups. Venular diameter was significantly reduced in all glaucoma groups compared to normal controls (P<0.001, but no such change was observed in arteriolar diameter (P=0.10. When comparing between eyes of asymmetrical glaucoma severity, arteriolar oxygen saturation (P=0.03 and AV difference (P=0.04 were significantly higher, while arteriolar diameter was significantly lower (P=0.001 in the worse eye in PACG group. There were no significant

  19. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    OpenAIRE

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Karl G Stonecipher,1 Jenny Chia,2 Ahunna Onyenwenyi,2 Linda Villanueva,2 David A Hollander2 1TLC Laser Eye Centers, Greensboro, NC, 2Allergan, Inc., Irvine, CA, USA Background: Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based o...

  20. Comprehensive eye evaluation algorithm

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.

    2016-03-01

    In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.

  1. Inconsistencies Exist in National Estimates of Eye Care Services Utilization in the United States

    Directory of Open Access Journals (Sweden)

    Fernando A. Wilson

    2015-01-01

    Full Text Available Background. There are limited research and substantial uncertainty about the level of eye care utilization in the United States. Objectives. Our study estimated eye care utilization using, to our knowledge, every known nationally representative, publicly available database with information on office-based optometry or ophthalmology services. Research Design. We analyzed the following national databases to estimate eye care utilization: the Medical Expenditure Panel Survey (MEPS, National Health Interview Survey (NHIS, Joint Canada/US Survey of Health (JCUSH, Behavioral Risk Factor Surveillance System (BRFSS, and the National Ambulatory Medical Care Survey (NAMCS. Subjects. US adults aged 18 and older. Measures. Self-reported utilization of eye care services. Results. The weighted number of adults seeing or talking with any eye doctor ranges from 87.9 million to 99.5 million, and the number of visits annually ranges from 72.9 million to 142.6 million. There were an estimated 17.2 million optometry visits and 55.8 million ophthalmology visits. Conclusions. The definitions and estimates of eye care services vary widely across national databases, leading to substantial differences in national estimates of eye care utilization.

  2. Aerosol container-related eye injuries in the United States: 1997-2009.

    Science.gov (United States)

    Seidman, Carly J; Linakis, James G; Mello, Michael J; Greenberg, Paul B

    2011-06-01

    To quantify and characterize eye injuries related to aerosol container consumer products treated in United States hospital emergency departments (EDs) from 1997 through 2009. Retrospective study. Descriptive analysis of aerosol container-related eye injury data derived from the National Electronic Injury Surveillance System, a stratified probability sample of hospital-affiliated United States EDs. Data collected included demographic variables (gender and age), locale, diagnoses, and hospital disposition associated with aerosol container-related eye injuries treated in United States EDs from 1997 through 2009. Products associated with injury and mechanisms of injury also were extracted and analyzed. There were an estimated 10 765 (95% confidence interval [CI], 9842 to 11 688) visits to United States EDs for aerosol container-related eye injuries during the study period; 6756 (95% CI, 5771 to 7742; 63%) patients were male; 5927 (95% CI, 4956 to 6897; 55%) injuries occurred in children (age container-related eye injuries in the United States occur in men and children and that self-inflicted spray to the eye is the most common mechanism of injury. Further research is needed to devise effective prevention strategies for these types of injuries. Published by Elsevier Inc.

  3. Managing eye injuries

    Directory of Open Access Journals (Sweden)

    Dorothy Mutie

    2016-01-01

    Full Text Available Based on what you found during the eye examination, classify the injury as a non-mechanical injury (chemical or thermal injury, a non-globe injury (orbital or adnexal injury or as a mechanical globe injury. In the case of mechanical globe injuries, it is important to classify the injury according to the Birmingham Eye Trauma Terminology System (BETTS and write it down in the patient’s notes; this will help to ensure that everyone involved in caring for the patient will have a consistent understanding of the type of injury. The resulting uniformity of terminology also helps with research, making it possible to compare data and do audits of injuries – which is essential for prevention.

  4. Six-year clinical study of firework-related eye injuries in North China.

    Science.gov (United States)

    Kong, Yichun; Tang, Xin; Kong, Baohuan; Jiang, Hao; Chen, Ying

    2015-01-01

    To analyse the demographic data, clinical characteristics, management and prognosis of patients with firework-related eye injuries. A retrospective review was performed of patients with eye injuries related to fireworks referred to TianJin Eye Hospital in North China from 2008 to 2013. Demographic information, clinical features, management and visual outcome were analysed and prognosis factors were evaluated. Ninety-nine patients (86 men) with 118 eye injuries were enrolled in the study. The average age of the patients was 32.0±20.5 years; 70/99 (70.7%) were aged >20 years. Eighty-one of the patients had been lighting the fireworks while the rest were bystanders. The main ophthalmic manifestations were hyphaema, vitreous haemorrhage, corneal/sclera/corneoscleral open globe injury, eyelid laceration, traumatic cataract, retinal/choroid detachment, endophthalmitis and intraocular foreign body (IOFB). Ninety patients required surgical intervention including repair of open globe injury, vitrectomy, cataract extraction and enucleation. 56/118 eyes (47.5%) received multiple operations. After treatment, final best-corrected visual acuity (BCVA) significantly improved (p=0.015). Some factors were significantly correlated with better final BCVA, including initial BCVA (p=0.036), closed globe injury (p=0.031), absence of endophthalmitis (p=0.014), absence of IOFB (p=0.024) and absence of retinal detachment (p=0.046). Firework-related eye injuries mainly occur in adult men and result in severe visual damage. The most common clinical manifestations are hyphaema and vitreous haemorrhage. Better initial BCVA and closed globe injury have a better visual result while endophthalmitis, IOFB and retinal detachment have a negative visual outcome. Improved eye protection, along with enhanced public education and legal ban on fireworks, could reduce the incidence of eye injuries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  5. Towards understanding addiction factors of mobile devices: An eye tracking study on effect of screen size.

    Science.gov (United States)

    Wibirama, Sunu; Nugroho, Hanung A

    2017-07-01

    Mobile devices addiction has been an important research topic in cognitive science, mental health, and human-machine interaction. Previous works observed mobile device addiction by logging mobile devices activity. Although immersion has been linked as a significant predictor of video game addiction, investigation on addiction factors of mobile device with behavioral measurement has never been done before. In this research, we demonstrated the usage of eye tracking to observe effect of screen size on experience of immersion. We compared subjective judgment with eye movements analysis. Non-parametric analysis on immersion score shows that screen size affects experience of immersion (pmobile devices addiction. Our experimental results are also useful to develop a guideline as well as intervention strategy to deal with smartphone addiction.

  6. Estimation of the mechanical properties of the eye through the study of its vibrational modes.

    Directory of Open Access Journals (Sweden)

    M Á Aloy

    Full Text Available Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral analysis of the eyeball vibrational modes has not been performed yet. Here we develop a new finite difference method to compute both the spheroidal and, specially, the toroidal eigenfrequencies of the human eye. Using this numerical model, we show that the vibrational eigenfrequencies of the human eye fall in the interval 100 Hz-10 MHz. We find that compressible vibrational modes may release a trace on high frequency changes of the intraocular pressure, while incompressible normal modes could be registered analyzing the scattering pattern that the motions of the vitreous humour leave on the retina. Existing contact lenses with embebed devices operating at high sampling frequency could be used to register the microfluctuations of the eyeball shape we obtain. We advance that an inverse problem to obtain the mechanical properties of a given eye (e.g., Young's modulus, Poisson ratio measuring its normal frequencies is doable. These measurements can be done using non-invasive techniques, opening very interesting perspectives to estimate the mechanical properties of eyes in vivo. Future research might relate various ocular pathologies with anomalies in measured vibrational frequencies of the eye.

  7. Attentional bias to betel quid cues: An eye tracking study.

    Science.gov (United States)

    Shen, Bin; Chiu, Meng-Chun; Li, Shuo-Heng; Huang, Guo-Joe; Liu, Ling-Jun; Ho, Ming-Chou

    2016-09-01

    The World Health Organization regards betel quid as a human carcinogen, and DSM-IV and ICD-10 dependence symptoms may develop with heavy use. This study, conducted in central Taiwan, investigated whether betel quid chewers can exhibit overt orienting to selectively respond to the betel quid cues. Twenty-four male chewers' and 23 male nonchewers' eye movements to betel-quid-related pictures and matched pictures were assessed during a visual probe task. The eye movement index showed that betel quid chewers were more likely to initially direct their gaze to the betel quid cues, t(23) = 3.70, p betel quid chewers' attentional bias. The results demonstrated that the betel quid chewers (but not the nonchewers) were more likely to initially direct their gaze to the betel quid cues, and spent more time and were more fixated on them. These findings suggested that when attention is directly measured through the eye tracking technique, this methodology may be more sensitive to detecting attentional biases in betel quid chewers. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  8. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  9. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  10. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  11. Awareness and eye health-seeking practices for cataract among urban slum population of Delhi: The North India eye disease awareness study.

    Science.gov (United States)

    Misra, Vasundhra; Vashist, Praveen; Singh, Senjam Suraj; Malhotra, Sumit; Gupta, Vivek; Dwivedi, S N; Gupta, Sanjeev K

    2017-12-01

    The objective of the study was to assess the awareness and health-seeking practices related to cataract in urban slums of Delhi. This study design was a population-based cross-sectional study. Participants aged 18-60 years were recruited from randomly selected five slums of South Delhi. They were interviewed using a semi-structured interview schedule on awareness and eye health-seeking practices related to cataract. The practices were recorded if the respondents themselves or any other member of the family was diagnosed with cataract in previous 2 years. A total of 1552 respondents participated in the study, of which, 89.9% had heard of cataract but only (42%) were aware of any symptom of cataract. The common symptoms of cataract reported by the participants were white opacity in eyes (25.9%) and loss of vision (20.6%). Surgery as a treatment of cataract was known to only 559 (40.1%) participants. Awareness about surgery as treatment of cataract was significantly higher among people aged 45-60 years (adjusted odds ratio = 2.89, 95% confidence interval = 2.11-3.97) and in educated people (adjusted OR = 3.69 95% CI = 2.37-5.73). Out of 84 respondents who had been diagnosed with cataract, the health-seeking practices were observed by 70 (83.3%) participants. Among them, 51 (72.9%) had undergone surgery and another 19 (27.1%) had been advised to wait for surgery. Most of the operated patients 48 (94.1%) attended the postoperative follow-up. The study findings suggest the majority of participants have heard of cataract, but there is low awareness of its symptoms and treatment, and good eye health-seeking practices observed for cataract in urban slum population. Gaps in awareness observed can be filled up by implementing proper eye health education programs.

  12. Human eye localization using the modified Hough transform

    Czech Academy of Sciences Publication Activity Database

    Dobeš, M.; Martínek, J.; Skoupil, D.; Dobešová, Z.; Pospíšil, Jaroslav

    2006-01-01

    Roč. 117, - (2006), s. 468-473 ISSN 0030-4026 Institutional research plan: CEZ:AV0Z10100522 Keywords : human eye localization * modified Hough transform * eye iris and eyelid shape determination Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.585, year: 2006

  13. Exploring Text and Icon Graph Interpretation in Students with Dyslexia: An Eye-tracking Study.

    Science.gov (United States)

    Kim, Sunjung; Wiseheart, Rebecca

    2017-02-01

    A growing body of research suggests that individuals with dyslexia struggle to use graphs efficiently. Given the persistence of orthographic processing deficits in dyslexia, this study tested whether graph interpretation deficits in dyslexia are directly related to difficulties processing the orthographic components of graphs (i.e. axes and legend labels). Participants were 80 college students with and without dyslexia. Response times and eye movements were recorded as students answered comprehension questions about simple data displayed in bar graphs. Axes and legends were labelled either with words (mixed-modality graphs) or icons (orthography-free graphs). Students also answered informationally equivalent questions presented in sentences (orthography-only condition). Response times were slower in the dyslexic group only for processing sentences. However, eye tracking data revealed group differences for processing mixed-modality graphs, whereas no group differences were found for the orthography-free graphs. When processing bar graphs, students with dyslexia differ from their able reading peers only when graphs contain orthographic features. Implications for processing informational text are discussed. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Speaking and Listening with the Eyes: Gaze Signaling during Dyadic Interactions.

    Science.gov (United States)

    Ho, Simon; Foulsham, Tom; Kingstone, Alan

    2015-01-01

    Cognitive scientists have long been interested in the role that eye gaze plays in social interactions. Previous research suggests that gaze acts as a signaling mechanism and can be used to control turn-taking behaviour. However, early research on this topic employed methods of analysis that aggregated gaze information across an entire trial (or trials), which masks any temporal dynamics that may exist in social interactions. More recently, attempts have been made to understand the temporal characteristics of social gaze but little research has been conducted in a natural setting with two interacting participants. The present study combines a temporally sensitive analysis technique with modern eye tracking technology to 1) validate the overall results from earlier aggregated analyses and 2) provide insight into the specific moment-to-moment temporal characteristics of turn-taking behaviour in a natural setting. Dyads played two social guessing games (20 Questions and Heads Up) while their eyes were tracked. Our general results are in line with past aggregated data, and using cross-correlational analysis on the specific gaze and speech signals of both participants we found that 1) speakers end their turn with direct gaze at the listener and 2) the listener in turn begins to speak with averted gaze. Convergent with theoretical models of social interaction, our data suggest that eye gaze can be used to signal both the end and the beginning of a speaking turn during a social interaction. The present study offers insight into the temporal dynamics of live dyadic interactions and also provides a new method of analysis for eye gaze data when temporal relationships are of interest.

  15. Speaking and Listening with the Eyes: Gaze Signaling during Dyadic Interactions.

    Directory of Open Access Journals (Sweden)

    Simon Ho

    Full Text Available Cognitive scientists have long been interested in the role that eye gaze plays in social interactions. Previous research suggests that gaze acts as a signaling mechanism and can be used to control turn-taking behaviour. However, early research on this topic employed methods of analysis that aggregated gaze information across an entire trial (or trials, which masks any temporal dynamics that may exist in social interactions. More recently, attempts have been made to understand the temporal characteristics of social gaze but little research has been conducted in a natural setting with two interacting participants. The present study combines a temporally sensitive analysis technique with modern eye tracking technology to 1 validate the overall results from earlier aggregated analyses and 2 provide insight into the specific moment-to-moment temporal characteristics of turn-taking behaviour in a natural setting. Dyads played two social guessing games (20 Questions and Heads Up while their eyes were tracked. Our general results are in line with past aggregated data, and using cross-correlational analysis on the specific gaze and speech signals of both participants we found that 1 speakers end their turn with direct gaze at the listener and 2 the listener in turn begins to speak with averted gaze. Convergent with theoretical models of social interaction, our data suggest that eye gaze can be used to signal both the end and the beginning of a speaking turn during a social interaction. The present study offers insight into the temporal dynamics of live dyadic interactions and also provides a new method of analysis for eye gaze data when temporal relationships are of interest.

  16. Research on moving object detection based on frog's eyes

    Science.gov (United States)

    Fu, Hongwei; Li, Dongguang; Zhang, Xinyuan

    2008-12-01

    On the basis of object's information processing mechanism with frog's eyes, this paper discussed a bionic detection technology which suitable for object's information processing based on frog's vision. First, the bionics detection theory by imitating frog vision is established, it is an parallel processing mechanism which including pick-up and pretreatment of object's information, parallel separating of digital image, parallel processing, and information synthesis. The computer vision detection system is described to detect moving objects which has special color, special shape, the experiment indicates that it can scheme out the detecting result in the certain interfered background can be detected. A moving objects detection electro-model by imitating biologic vision based on frog's eyes is established, the video simulative signal is digital firstly in this system, then the digital signal is parallel separated by FPGA. IN the parallel processing, the video information can be caught, processed and displayed in the same time, the information fusion is taken by DSP HPI ports, in order to transmit the data which processed by DSP. This system can watch the bigger visual field and get higher image resolution than ordinary monitor systems. In summary, simulative experiments for edge detection of moving object with canny algorithm based on this system indicate that this system can detect the edge of moving objects in real time, the feasibility of bionic model was fully demonstrated in the engineering system, and it laid a solid foundation for the future study of detection technology by imitating biologic vision.

  17. Trends and topics in eye disease research in PubMed from 2010 to 2014.

    Science.gov (United States)

    Boudry, Christophe; Denion, Eric; Mortemousque, Bruno; Mouriaux, Fréderic

    2016-01-01

    The purpose of this study is to provide a report on scientific production during the period 2010-2014 in order to identify the major topics as well as the predominant actors (journals, countries, continents) involved in the field of eye disease. A PubMed search was carried out to extract articles related to eye diseases during the period 2010-2014. Data were downloaded and processed through developed PHP scripts for further analysis. A total of 62,123 articles were retrieved. A total of 3,368 different journals were found, and 19 journals were identified as "core journals" according to Braford's law. English was by far the predominant language. A total of 853,182 MeSH terms were found, representing an average of 13.73 (SD = 4.98) MeSH terms per article. Among these 853,182 MeSH terms, 14,689 different MeSH terms were identified. Vision Disorders, Glaucoma, Diabetic Retinopathy, Macular Degeneration, and Cataract were the most frequent five MeSH terms related to eye diseases. The analysis of the total number of publications showed that Europe and Asia were the most productive continents, and the USA and China the most productive countries. Interestingly, using the mean Five-Year Impact Factor, the two most productive continents were North America and Oceania. After adjustment for population, the overall ranking positions changed in favor of smaller countries (i.e. Iceland, Switzerland, Denmark, and New Zealand), while after adjustment for Gross Domestic Product (GDP), the overall ranking positions changed in favor of some developing countries (Malawi, Guatemala, Singapore). Due to the large number of articles included and the numerous parameters analyzed, this study provides a wide view of scientific productivity related to eye diseases during the period 2010-2014 and allows us to better understand this field.

  18. Influence of eye diseases on the mortality rate of the population

    Directory of Open Access Journals (Sweden)

    Andrey V. Zolotarev

    2018-03-01

    Full Text Available Evaluating of the correlation between quality of life, life expectancy and mortality rate is an important problem of modern ophthalmology. Many researchers note that eye pathology, which leads to a visual acuity decrease and blindness, has a significant impact on the mortality rate of the population. This review of literature is dedicated to studies examining the impact of eye diseases on the mortality rate of the population.

  19. Fluid Mixing in the Eye Under Rapid Eye Movement

    Science.gov (United States)

    Huang, Jinglin; Gharib, Morteza

    2017-11-01

    Drug injection is an important technique in certain treatments of eye diseases. The efficacy of chemical mixing plays an important role in determining pharmacokinetics of injected drugs. In this study, we build a device to study the chemical mixing behavior in a spherical structure. The mixing process is visualized and analyzed qualitatively. We hope to understand the chemical convection and diffusion behaviors in correlation with controlled rapid mechanical movements. The results will have potential applications in treatment of eye diseases. Resnick Institute at Caltech.

  20. Intense pulsed light therapy for the treatment of evaporative dry eye disease.

    Science.gov (United States)

    Vora, Gargi K; Gupta, Preeya K

    2015-07-01

    Evaporative dry eye disease is one of the most common types of dry eye. It is often the result of chronic meibomian gland dysfunction (MGD) and associated ocular rosacea. Evaporative dry eye and MGD significantly reduce patient's quality of life. Traditional treatments, such as artificial tears, warm compresses, and medications, such as topical cyclosporine, azithromycin, and oral doxycycline, provide some relief; however, many patients still suffer from dry eye symptoms. Intense pulsed light (IPL) therapy, which has been used extensively in dermatology to treat chronic skin conditions, is a relatively new treatment in ophthalmology for patients with evaporative dry eye disease. There are very few studies published on the use of IPL in patients with dry eye disease. The present review describes the theoretical mechanisms of IPL treatment of MGD and ocular rosacea. Personal clinical experience and recently presented data are reported as well. IPL therapy has promising results for evaporative dry eye patients. There are statistically significant improvements in clinical exam findings of dry eye disease. More importantly, patients report subjective improvement in their symptoms. More research is needed in this area to help understand the mechanism of dry eye disease and how it can be effectively treated.

  1. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    Science.gov (United States)

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Eye surface temperature detects stress response in budgerigars (Melopsittacus undulatus).

    Science.gov (United States)

    Ikkatai, Yuko; Watanabe, Shigeru

    2015-08-05

    Previous studies have suggested that stressors not only increase body core temperature but also body surface temperature in many animals. However, it remains unclear whether surface temperature could be used as an alternative to directly measure body core temperature, particularly in birds. We investigated whether surface temperature is perceived as a stress response in budgerigars. Budgerigars have been used as popular animal models to investigate various neural mechanisms such as visual perception, vocal learning, and imitation. Developing a new technique to understand the basic physiological mechanism would help neuroscience researchers. First, we found that cloacal temperature correlated with eye surface temperature. Second, eye surface temperature increased after handling stress. Our findings suggest that eye surface temperature is closely related to cloacal temperature and that the stress response can be measured by eye surface temperature in budgerigars.

  3. Improving eye safety in citrus harvest crews through the acceptance of personal protective equipment, community-based participatory research, social marketing, and community health workers.

    Science.gov (United States)

    Tovar-Aguilar, J Antonio; Monaghan, Paul F; Bryant, Carol A; Esposito, Andrew; Wade, Mark; Ruiz, Omar; McDermott, Robert J

    2014-01-01

    For the last 10 years, the Partnership for Citrus Workers Health (PCWH) has been an evidence-based intervention program that promotes the adoption of protective eye safety equipment among Spanish-speaking farmworkers of Florida. At the root of this program is the systematic use of community-based preventive marketing (CBPM) and the training of community health workers (CHWs) among citrus harvester using popular education. CBPM is a model that combines the organizational system of community-based participatory research (CBPR) and the strategies of social marketing. This particular program relied on formative research data using a mixed-methods approach and a multilevel stakeholder analysis that allowed for rapid dissemination, effective increase of personal protective equipment (PPE) usage, and a subsequent impact on adoptive workers and companies. Focus groups, face-to-face interviews, surveys, participant observation, Greco-Latin square, and quasi-experimental tests were implemented. A 20-hour popular education training produced CHWs that translated results of the formative research to potential adopters and also provided first aid skills for eye injuries. Reduction of injuries is not limited to the use of safety glasses, but also to the adoption of timely intervention and regular eye hygiene. Limitations include adoption in only large companies, rapid decline of eye safety glasses without consistent intervention, technological limitations of glasses, and thorough cost-benefit analysis.

  4. Scleral lens use in dry eye syndrome.

    Science.gov (United States)

    Bavinger, J Clay; DeLoss, Karen; Mian, Shahzad I

    2015-07-01

    Dry eye syndrome can be difficult to manage in severe or refractory cases. In patients in whom traditional treatments have limited efficacy, alternative treatments may be considered for dry eye syndrome, including scleral lenses. The present review summarizes the evidence regarding scleral lens use in dry eye syndrome. Scleral lenses have become a viable option for severe dry eye syndrome, and have been shown to be efficacious and well tolerated, with most reports citing improved visual acuity and relief of symptoms. Currently, there are 18 manufacturers of scleral lenses, although published reports on scleral lenses primarily focus on the BostonSight PROSE and the Jupiter Lens. Scleral lenses are efficacious and well tolerated for use in severe dry eye syndrome. Further research is needed to compare different sizes and types of lenses, and to standardize outcome measures.

  5. What do your eyes say? Bridging eye movements to consumer behavior

    Directory of Open Access Journals (Sweden)

    Pedro Rosa

    2015-07-01

    Full Text Available Eye tracking (ET is a technique that has been progressively employed to study the influence of visual stimuli on attentional processes and consumer behavior. The goals of the present theoretical article are fourfold and are based on an extensive literature revision. First, a brief historical review of ET methodology is introduced, presenting the evolution of ET techniques from the ancient proto-eye trackers to the “fresh” state-of-theart eye ET devices. Second, the basics of ET are clarified through a simplified technical and mathematical explanation. Third, the triad eye movement-attention-consumer behavior is made clear, grounded on attention, interest, desire, and action (AIDA theoretical model. Fourth, the most used oculometrics in marketing studies are explained and distinguished The present article addresses a number of technical and methodological issues by discussing challenges involved in ET systems and giving some guidelines for those who intend to apply ET to infer cognitive and emotional processes.

  6. What checkers actually check: an eye tracking study of inhibitory control and working memory.

    Directory of Open Access Journals (Sweden)

    Ben Harkin

    Full Text Available Not only is compulsive checking the most common symptom in Obsessive Compulsive Disorder (OCD with an estimated prevalence of 50-80% in patients, but approximately ∼15% of the general population reveal subclinical checking tendencies that impact negatively on their performance in daily activities. Therefore, it is critical to understand how checking affects attention and memory in clinical as well as subclinical checkers. Eye fixations are commonly used as indicators for the distribution of attention but research in OCD has revealed mixed results at best.Here we report atypical eye movement patterns in subclinical checkers during an ecologically valid working memory (WM manipulation. Our key manipulation was to present an intermediate probe during the delay period of the memory task, explicitly asking for the location of a letter, which, however, had not been part of the encoding set (i.e., misleading participants. Using eye movement measures we now provide evidence that high checkers' inhibitory impairments for misleading information results in them checking the contents of WM in an atypical manner. Checkers fixate more often and for longer when misleading information is presented than non-checkers. Specifically, checkers spend more time checking stimulus locations as well as locations that had actually been empty during encoding.We conclude that these atypical eye movement patterns directly reflect internal checking of memory contents and we discuss the implications of our findings for the interpretation of behavioural and neuropsychological data. In addition our results highlight the importance of ecologically valid methodology for revealing the impact of detrimental attention and memory checking on eye movement patterns.

  7. Perceptions of elementary school teachers of their pupils\\' eye ...

    African Journals Online (AJOL)

    Perceptions of elementary school teachers of their pupils\\' eye health in ilorin, nigeria. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... roles that school teachers are expected to play in school eye health programmes, their perceptions ...

  8. Study design and baseline findings from the progression of ocular findings (PROOF) natural history study of dry eye.

    Science.gov (United States)

    McDonnell, Peter J; Pflugfelder, Stephen C; Stern, Michael E; Hardten, David R; Conway, Taryn; Villanueva, Linda; Hollander, David A

    2017-12-28

    The aim of this research is to initiate a 5-year natural history study of dry eye disease (DED) using objectively assessed and patient-reported outcomes, to explore the hypothesis that DED is a progressive condition that has substantive and measurable impacts not only on the ocular surface, but on quality of life and visual functioning. Our objective for this report is to examine the baseline data. A multicenter, prospective, controlled, observational study of Level 2 (mild-to-moderate) DED patients based on International Task Force Delphi Panel severity grading, and controls, documented baseline measures (including tear film biomarkers and quality of life). Tear cytokine concentrations were also measured in the tear film. Patients were using artificial tears as needed. Two hundred seventeen DED patients and 67 gender- and age-matched controls were enrolled. A majority were females and Caucasian and groups did not differ significantly in terms of gender, race, or age. Differences between DED and matched controls, at baseline, included mean scores for Ocular Surface Disease Index (31.7 vs 4.1, P eye care practitioners in mild to moderate DED patients compared to normal subjects of similar ages and genders. ClinicalTrials.gov NCT00833235 on January 30, 2009.

  9. Treatment of Dry Eye Disease.

    Science.gov (United States)

    Marshall, Leisa L; Roach, J Michael

    2016-02-01

    Review of the etiology, clinical manifestations, and treatment of dry eye disease (DED). Articles indexed in PubMed (National Library of Medicine), Iowa Drug Information Service (IDIS), and the Cochrane Reviews and Trials in the last 10 years using the key words "dry eye disease," "dry eye syndrome," "dry eye and treatment." Primary sources were used to locate additional resources. Sixty-eight publications were reviewed, and criteria supporting the primary objective were used to identify useful resources. The literature included practice guidelines, book chapters, review articles, original research articles, and product prescribing information for the etiology, clinical manifestations, diagnosis, and treatment of DED. DED is one of the most common ophthalmic disorders. Signs and symptoms of DED vary by patient, but may include ocular irritation, redness, itching, photosensitivity, visual blurring, mucous discharge, and decreased tear meniscus or break-up time. Symptoms improve with treatment, but the condition is not completely curable. Treatment includes reducing environmental causes, discontinuing medications that cause or worsen dry eye, and managing contributing ocular or systemic conditions. Most patients use nonprescription tear substitutes, and if these are not sufficient, other treatment is prescribed. These treatments include the ophthalmic anti-inflammatory agent cyclosporine, punctal occlusion, eye side shields, systemic cholinergic agents, and autologous serum tears. This article reviews the etiology, symptoms, and current therapy for DED.

  10. Symptomatic Dry Eye and Its Associated Factors: A Study of University Undergraduate Students in Ghana.

    Science.gov (United States)

    Asiedu, Kofi; Kyei, Samuel; Boampong, Frank; Ocansey, Stephen

    2017-07-01

    To estimate the prevalence and risk factors of symptomatic dry eye disease (DED) among undergraduate students in a Ghanaian university. This cross-sectional study included 700 undergraduate students of the University of Cape Coast, aged 18 to 34 years. Participants completed questionnaires delivered directly to randomly and systematically selected subjects to detect symptomatic dry eye and its predictive factors. Symptomatic dry eye was defined as any reported symptom on the Standard Patient Evaluation Eye Dryness (SPEED) questionnaire reported as often or constant or if any symptom on the Ocular Surface Disease Index (OSDI) was reported as most of the time or all of the time. Furthermore, OSDI ≥13 and SPEED ≥6 were used to defined symptomatic dry eye and prevalence were also estimated with these criteria as secondary measures. Current symptoms of dry eye and possible risk factors such as age, gender, current alcohol drinking, use of oral contraceptives, use of computer more than an hour daily, environmental conditions, allergies, and self-medication with over-the-counter eye drops were the main outcome measures. We used logistic regression analysis to examine the associations between dry eye and its predictive factors. Of the 700 participants, 650 completed the questionnaire. The prevalence of symptomatic dry eye was 44.3% (95% confidence interval [CI], 40.6%-48.2%). There was a significant association between symptomatic dry eye and discomfort with eyes in windy conditions (χ=110.1; df=4; Peye drops (OR 4.20; 95% CI, 2.61-6.74; Pdry eye. Sex was predictive in univariate analysis but was not significantly associated in multivariate analysis. The prevalence of symptomatic dry eye among undergraduate students in Ghana is high and it is associated with self-medication with over-the-counter eye drops, allergies, use of oral contraceptive, windy conditions, very low humid areas, air-conditioned rooms, and sex. Relevant input directed against modifiable risks

  11. A comparative study of Bilvadi Yoga Ashchyotana and eye drops in Vataja Abhishyanda (Simple Allergic Conjunctivitis).

    Science.gov (United States)

    Udani, Jayshree; Vaghela, D B; Rajagopala, Manjusha; Matalia, P D

    2012-01-01

    Simple allergic conjunctivitis is the most common form of ocular allergy (prevalence 5 - 22 %). It is a hypersensitivity reaction to specific airborne antigens. The disease Vataja Abhishyanda, which is due to vitiation of Vata Pradhana Tridosha is comparable with this condition. The management of simple allergic conjunctivitis in modern ophthalmology is very expensive and it should be followed lifelong and Ayurveda can provide better relief in such manifestation. This is the first research study on Vataja Abhishyanda. Patients were selected from the Outpatient Department (OPD), Inpatient Department (IPD), of the Shalakya Tantra Department and were randomly divided into two groups. In Group-A Bilvadi Ashchyotana and in Group-B Bilvadi eye drops were instilled for three months. Total 32 patients were registered and 27 patients completed the course of treatment. Bilvadi Ashchyotana gave better results in Toda, Sangharsha, Parushya, Kandu and Ragata as compared with Bilvadi Eye Drops in Vataja Abhishyanda.

  12. A clinical study of the efficacy of topical corticosteroids on dry eye

    OpenAIRE

    Yang, Chong-qing; Sun, Wen; Gu, Yang-shun

    2006-01-01

    Objective: To evaluate the effect of topical corticosteroid for treatment of moderate or severe dry eye. Methods: Sixty eyes of 30 patients with moderate or severe dry eye, who were not sensitive to artificial tears, were treated with 0.1% fluorometholone eye drops. Subjective symptom and objective tests were used to evaluate the efficacy of treatment before and after application of 0.1% fluorometholone eye drops for 1 week and 1 month. Side effects were also evaluated. Results: After 1 week ...

  13. Effect of Autologous Serum Eye Drops in Patients with Sjögren Syndrome-related Dry Eye: Clinical and In Vivo Confocal Microscopy Evaluation of the Ocular Surface.

    Science.gov (United States)

    Semeraro, Francesco; Forbice, Eliana; Nascimbeni, Giuseppe; Taglietti, Marco; Romano, Vito; Guerra, Germano; Costagliola, Ciro

    To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thickness, tear film, break-up time, corneal and conjunctival staining, Schirmer's test and corneal confocal microscopy were investigated. Tear production, tear stability, corneal staining, inflammation, and central corneal thickness, Langherans cells, activated keratocytes, intermediate epithelial cell density, nerve tortuosity, number of sub-basal nerve branches, and number of bead-like formations differed between patients and controls (peye drops improve symptoms and confocal microscopy findings in SS-related dry eyes. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  14. How are learning strategies reflected in the eyes? Combining results from self-reports and eye-tracking.

    Science.gov (United States)

    Catrysse, Leen; Gijbels, David; Donche, Vincent; De Maeyer, Sven; Lesterhuis, Marije; Van den Bossche, Piet

    2018-03-01

    Up until now, empirical studies in the Student Approaches to Learning field have mainly been focused on the use of self-report instruments, such as interviews and questionnaires, to uncover differences in students' general preferences towards learning strategies, but have focused less on the use of task-specific and online measures. This study aimed at extending current research on students' learning strategies by combining general and task-specific measurements of students' learning strategies using both offline and online measures. We want to clarify how students process learning contents and to what extent this is related to their self-report of learning strategies. Twenty students with different generic learning profiles (according to self-report questionnaires) read an expository text, while their eye movements were registered to answer questions on the content afterwards. Eye-tracking data were analysed with generalized linear mixed-effects models. The results indicate that students with an all-high profile, combining both deep and surface learning strategies, spend more time on rereading the text than students with an all-low profile, scoring low on both learning strategies. This study showed that we can use eye-tracking to distinguish very strategic students, characterized using cognitive processing and regulation strategies, from low strategic students, characterized by a lack of cognitive and regulation strategies. These students processed the expository text according to how they self-reported. © 2017 The British Psychological Society.

  15. Attitudes and Perception Towards Eye Donation in Patients with Corneal Disease: A Case-controlled Population-based Study.

    Science.gov (United States)

    Noopur, Gupta; Praveen, Vashist; Radhika, Tandon; Sanjeev K, Gupta; Mani, Kalaivani; Deepak, Kumar

    2018-06-01

    To assess awareness, barriers, and misconceptions related to eye donation in people with corneal disease as compared to controls in a population setting. A population-based study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India, as part of the CORE (Cornea Opacity Rural Epidemiological) study. In addition to ophthalmic examination, knowledge and perceptions regarding eye donation were assessed through a validated questionnaire. The questionnaire captured the sociodemographic factors influencing awareness regarding eye donation in participants with corneal disease and twice the number of age- and gender-matched controls recruited from the same study clusters. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for awareness of eye donation. In the CORE study, 452 participants had corneal opacities on ocular examination. Of these, 442 were assessed for eye donation awareness. Additionally, 884 age- and gender-matched controls were recruited. The mean age of cases and controls was 60.9 ± 15.5 and 59.6 ± 14.3 years, respectively. Awareness of eye donation in cases and controls was 46.4% (n = 205 of 442) and 52.3% (n = 462 of 884), respectively (P = 0.044). Educational status was an important factor determining knowledge about eye donation in both cases and controls (P = donated before death or even after 24 h of death and that any type of blindness could be treated with corneal transplantation were prevalent. The study demonstrated that although there is substantial awareness about eye donation, there are numerous barriers in this population that need to be resolved to improve donation rates. Additional efforts are needed to translate this awareness into actual eye donation in both cases with corneal disease and controls.

  16. Biocompatibility and biodegradation studies of subconjunctival implants in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Yan Peng

    Full Text Available Sustained ocular drug delivery is difficult to achieve. Most drugs have poor penetration due to the multiple physiological barriers of the eye and are rapidly cleared if applied topically. Biodegradable subconjunctival implants with controlled drug release may circumvent these two problems. In our study, two microfilms (poly [d,l-lactide-co-glycolide] PLGA and poly[d,l-lactide-co-caprolactone] PLC were developed and evaluated for their degradation behavior in vitro and in vivo. We also evaluated the biocompatibility of both microfilms. Eighteen eyes (9 rabbits were surgically implanted with one type of microfilm in each eye. Serial anterior-segment optical coherence tomography (AS-OCT scans together with serial slit-lamp microscopy allowed us to measure thickness and cross-sectional area of the microfilms. In vitro studies revealed bulk degradation kinetics for both microfilms, while in vivo studies demonstrated surface erosion kinetics. Serial slit-lamp microscopy revealed no significant inflammation or vascularization in both types of implants (mean increase in vascularity grade PLGA50/50 12±0.5% vs. PLC70/30 15±0.6%; P = 0.91 over a period of 6 months. Histology, immunohistochemistry and immuno-fluorescence also revealed no significant inflammatory reaction from either of the microfilms, which confirmed that both microfilms are biocompatible. The duration of the drug delivery can be tailored by selecting the materials, which have different degradation kinetics, to suit the desired clinical therapeutic application.

  17. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  18. An Eye-tracking Study of Feature-based Choice in One-shot Games

    DEFF Research Database (Denmark)

    Devetag, Giovanna; Di Guida, Sibilla; Polonio, Luca

    2016-01-01

    for a subset of game outcomes. We analyze subjects’ eye movements while playing a series of two-person, 3x3 one-shot games in normal form. Games within each class differ by a set of descriptive features (i.e., features that can be changed without altering the game equilibrium properties). Data show......Previous experimental research suggests that individuals apply rules of thumb to a simplified mental model of the "real" decision problem. We claim that this simplification is obtained either by neglecting the other players' incentives and beliefs or by taking them into consideration only...... that subjects on average perform partial or non-strategic analysis of the payoff matrix, often ignoring the opponent´s payoffs and rarely performing the necessary steps to detect dominance. Our analysis of eye-movements supports the hypothesis that subjects use simple decision rules such as "choose the strategy...

  19. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  20. Coping with dry eyes: a qualitative approach.

    Science.gov (United States)

    Yeo, Sharon; Tong, Louis

    2018-01-16

    Dry eye is a common problem that affects many people worldwide, reducing quality of life and impacting daily activities. A qualitative approach often used in medicine and other disciplines is used to evaluate how people with dry eye cope with this impact. Six focus group sessions were conducted at the Singapore National Eye Centre (SNEC), premises of an eye research institute. These focus groups consist of a spectrum of dry eye sufferers (30 women, 8 men, aged 61 ± 11.8 years). Standard methods of coding followed by determination of themes were adhered to. Where classification was difficult, consensus was made between 3 assessors. Audio-recorded transcripts were coded in 10 themes by 3 assessors independently. Four of the themes involved traditional measures such as lid warming, cleansing, lubrication and oral dietary supplements. The other themes discovered were Traditional Chinese Medicine, modification of eye-care habits (e.g. wearing sunglasses), environmental humidity, lifestyle (e.g. sleeping habits), psychological attitude, and lastly sharing and communication. Holistic coping strategies were found to be prominent in dry eye sufferers from these focus groups, and people tend to find personalised ways of coping with the impact of dry eye on daily living.

  1. Challenges in horizontal integration of eye care services into the pre-existing rural primary care structure: an operations research perspective from Nigeria

    OpenAIRE

    Chinyere Nkemdilim Ezisi; Boniface Ikenna Eze; Obiekwe Okoye; Chimdi Memnofu Chuka-Okosa; Jude Obinna Shiweobi

    2017-01-01

    Background . The provision of population-wide, accessible, affordable, acceptable and evenly distributed qualitative eye care services remains a recurrent challenge to eye care organizations worldwide. Objectives . To report the challenges encountered in setting up eye care service in a pre-existing primary health care facility in rural Nigeria and also audit the common causes of eye disorders in rural setting southeast of Nigeria. Material and methods . The study was an operations ...

  2. Combining user logging with eye tracking for interactive and dynamic applications.

    Science.gov (United States)

    Ooms, Kristien; Coltekin, Arzu; De Maeyer, Philippe; Dupont, Lien; Fabrikant, Sara; Incoul, Annelies; Kuhn, Matthias; Slabbinck, Hendrik; Vansteenkiste, Pieter; Van der Haegen, Lise

    2015-12-01

    User evaluations of interactive and dynamic applications face various challenges related to the active nature of these displays. For example, users can often zoom and pan on digital products, and these interactions cause changes in the extent and/or level of detail of the stimulus. Therefore, in eye tracking studies, when a user's gaze is at a particular screen position (gaze position) over a period of time, the information contained in this particular position may have changed. Such digital activities are commonplace in modern life, yet it has been difficult to automatically compare the changing information at the viewed position, especially across many participants. Existing solutions typically involve tedious and time-consuming manual work. In this article, we propose a methodology that can overcome this problem. By combining eye tracking with user logging (mouse and keyboard actions) with cartographic products, we are able to accurately reference screen coordinates to geographic coordinates. This referencing approach allows researchers to know which geographic object (location or attribute) corresponds to the gaze coordinates at all times. We tested the proposed approach through two case studies, and discuss the advantages and disadvantages of the applied methodology. Furthermore, the applicability of the proposed approach is discussed with respect to other fields of research that use eye tracking-namely, marketing, sports and movement sciences, and experimental psychology. From these case studies and discussions, we conclude that combining eye tracking and user-logging data is an essential step forward in efficiently studying user behavior with interactive and static stimuli in multiple research fields.

  3. Anti-inflammatory and antioxidant effects of Tualang honey in alkali injury on the eyes of rabbits: Experimental animal study

    Directory of Open Access Journals (Sweden)

    Sirajudeen KNS

    2011-10-01

    Full Text Available Abstract Background Alkali injury is one of the most devastating injuries to the eye. It results in permanent unilateral or bilateral visual impairment. Chemical eye injury is accompanied by an increase in the oxidative stress. Anti-inflammatory and antioxidant agents play a major role in the treatment of chemical eye injuries. The purpose of this study is to evaluate the anti-inflammatory (clinical and histopathological and antioxidant effects of Tualang honey versus conventional treatment in alkali injury on the eyes of rabbits. Methods A preliminary study was carried out prior to the actual study to establish the alkali chemical injury on rabbit's cornea and we found that alkali chemical injury with 2 N NaOH showed severe clinical inflammatory features. In actual study, alkali injury with 2 N NaOH was induced in the right eye of 10 New Zealand White rabbits' cornea. The rabbits were divided into two groups, Group A was given conventional treatment and Group B was treated with both topical and oral Tualang honey. Clinical inflammatory features of the right eye were recorded at 12 hours, 24 hours, 72 hours, 5th day and 7th day post induction of alkali burn on the cornea. The histopathological inflammatory features of the right corneas of all rabbits were also evaluated on day-7. The level of total antioxidant status and lipid peroxidation products in the aqueous humour, vitreous humour and serum at day-7 were estimated biochemically. Fisher's Exact, Chi-Square and Mann-Whitney test were used to analyse the data. Results There was no statistically significant difference in clinical inflammatory features (p > 0.05 between honey treated and the conventional treated group at different times of examination. Histopathological examination of the cornea showed the number of polymorphonuclear leucocytes was below 50 for both groups (mild grade. There was also no significant difference in the level of total antioxidant status as well as lipid

  4. Anti-inflammatory and antioxidant effects of Tualang honey in alkali injury on the eyes of rabbits: experimental animal study.

    Science.gov (United States)

    Bashkaran, Karuppannan; Zunaina, Embong; Bakiah, Shaharuddin; Sulaiman, Siti Amrah; Sirajudeen, Kns; Naik, Venkatesh

    2011-10-09

    Alkali injury is one of the most devastating injuries to the eye. It results in permanent unilateral or bilateral visual impairment. Chemical eye injury is accompanied by an increase in the oxidative stress. Anti-inflammatory and antioxidant agents play a major role in the treatment of chemical eye injuries. The purpose of this study is to evaluate the anti-inflammatory (clinical and histopathological) and antioxidant effects of Tualang honey versus conventional treatment in alkali injury on the eyes of rabbits. A preliminary study was carried out prior to the actual study to establish the alkali chemical injury on rabbit's cornea and we found that alkali chemical injury with 2 N NaOH showed severe clinical inflammatory features. In actual study, alkali injury with 2 N NaOH was induced in the right eye of 10 New Zealand White rabbits' cornea. The rabbits were divided into two groups, Group A was given conventional treatment and Group B was treated with both topical and oral Tualang honey. Clinical inflammatory features of the right eye were recorded at 12 hours, 24 hours, 72 hours, 5th day and 7th day post induction of alkali burn on the cornea. The histopathological inflammatory features of the right corneas of all rabbits were also evaluated on day-7. The level of total antioxidant status and lipid peroxidation products in the aqueous humour, vitreous humour and serum at day-7 were estimated biochemically. Fisher's Exact, Chi-Square and Mann-Whitney test were used to analyse the data. There was no statistically significant difference in clinical inflammatory features (p > 0.05) between honey treated and the conventional treated group at different times of examination. Histopathological examination of the cornea showed the number of polymorphonuclear leucocytes was below 50 for both groups (mild grade). There was also no significant difference in the level of total antioxidant status as well as lipid peroxidation products in aqueous humour (p = 0.117, p = 0

  5. Anti-inflammatory and antioxidant effects of Tualang honey in alkali injury on the eyes of rabbits: Experimental animal study

    Science.gov (United States)

    2011-01-01

    Background Alkali injury is one of the most devastating injuries to the eye. It results in permanent unilateral or bilateral visual impairment. Chemical eye injury is accompanied by an increase in the oxidative stress. Anti-inflammatory and antioxidant agents play a major role in the treatment of chemical eye injuries. The purpose of this study is to evaluate the anti-inflammatory (clinical and histopathological) and antioxidant effects of Tualang honey versus conventional treatment in alkali injury on the eyes of rabbits. Methods A preliminary study was carried out prior to the actual study to establish the alkali chemical injury on rabbit's cornea and we found that alkali chemical injury with 2 N NaOH showed severe clinical inflammatory features. In actual study, alkali injury with 2 N NaOH was induced in the right eye of 10 New Zealand White rabbits' cornea. The rabbits were divided into two groups, Group A was given conventional treatment and Group B was treated with both topical and oral Tualang honey. Clinical inflammatory features of the right eye were recorded at 12 hours, 24 hours, 72 hours, 5th day and 7th day post induction of alkali burn on the cornea. The histopathological inflammatory features of the right corneas of all rabbits were also evaluated on day-7. The level of total antioxidant status and lipid peroxidation products in the aqueous humour, vitreous humour and serum at day-7 were estimated biochemically. Fisher's Exact, Chi-Square and Mann-Whitney test were used to analyse the data. Results There was no statistically significant difference in clinical inflammatory features (p > 0.05) between honey treated and the conventional treated group at different times of examination. Histopathological examination of the cornea showed the number of polymorphonuclear leucocytes was below 50 for both groups (mild grade). There was also no significant difference in the level of total antioxidant status as well as lipid peroxidation products in aqueous

  6. Antioxidant and inflammatory cytokine in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops.

    Science.gov (United States)

    Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul

    2014-07-03

    To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  7. Adaptive optics scanning laser ophthalmoscope using liquid crystal on silicon spatial light modulator: Performance study with involuntary eye movement

    Science.gov (United States)

    Huang, Hongxin; Toyoda, Haruyoshi; Inoue, Takashi

    2017-09-01

    The performance of an adaptive optics scanning laser ophthalmoscope (AO-SLO) using a liquid crystal on silicon spatial light modulator and Shack-Hartmann wavefront sensor was investigated. The system achieved high-resolution and high-contrast images of human retinas by dynamic compensation for the aberrations in the eyes. Retinal structures such as photoreceptor cells, blood vessels, and nerve fiber bundles, as well as blood flow, could be observed in vivo. We also investigated involuntary eye movements and ascertained microsaccades and drifts using both the retinal images and the aberrations recorded simultaneously. Furthermore, we measured the interframe displacement of retinal images and found that during eye drift, the displacement has a linear relationship with the residual low-order aberration. The estimated duration and cumulative displacement of the drift were within the ranges estimated by a video tracking technique. The AO-SLO would not only be used for the early detection of eye diseases, but would also offer a new approach for involuntary eye movement research.

  8. Baseline risk factors for incidence of blindness in a South Indian population: the chennai eye disease incidence study.

    Science.gov (United States)

    Vijaya, Lingam; Asokan, Rashima; Panday, Manish; Choudhari, Nikhil S; Ramesh, Sathyamangalam Ve; Velumuri, Lokapavani; Boddupalli, Sachi Devi; Sunil, Govindan T; George, Ronnie

    2014-08-07

    To report the baseline risk factors and causes for incident blindness. Six years after the baseline study, 4419 subjects from the cohort underwent a detailed examination at the base hospital. Incident blindness was defined by World Health Organization criteria as visual acuity of less than 6/120 (3/60) and/or a visual field of less than 10° in the better-seeing eye at the 6-year follow-up, provided that the eye had a visual acuity of better than or equal to 6/120 (3/60) and visual field greater than 10° at baseline. For incident monocular blindness, both eyes should have visual acuity of more than 6/120 (3/60) at baseline and developed visual acuity of less than 6/120 (3/60) in one eye at 6-year follow-up. For incident blindness, 21 participants (0.48%, 95% confidence interval [CI], 0.3-0.7) became blind; significant baseline risk factors were increasing age (P = 0.001), smokeless tobacco use (P blindness was found in 132 participants (3.8%, 95% CI, 3.7-3.8); it was significantly more (P blindness and monocular blindness. No history of cataract surgery was a risk factor for blindness and a protective factor for monocular blindness. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  9. Exploring Cultural Variation in Eye Movements on a Web Page between Americans and Koreans

    Science.gov (United States)

    Yang, Changwoo

    2009-01-01

    This study explored differences in eye movement on a Web page between members of two different cultures to provide insight and guidelines for implementation of global Web site development. More specifically, the research examines whether differences of eye movement exist between the two cultures (American vs. Korean) when viewing a Web page, and…

  10. Heritability of the severity of diabetic retinopathy: the FIND-Eye study.

    Science.gov (United States)

    Arar, Nedal H; Freedman, Barry I; Adler, Sharon G; Iyengar, Sudha K; Chew, Emily Y; Davis, Mathew D; Satko, Scott G; Bowden, Donald W; Duggirala, Ravi; Elston, Robert C; Guo, Xiuxing; Hanson, Robert L; Igo, Robert P; Ipp, Eli; Kimmel, Paul L; Knowler, William C; Molineros, Julio; Nelson, Robert G; Pahl, Madeleine V; Quade, Shannon R E; Rasooly, Rebekah S; Rotter, Jerome I; Saad, Mohammed F; Scavini, Marina; Schelling, Jeffrey R; Sedor, John R; Shah, Vallabh O; Zager, Philip G; Abboud, Hanna E

    2008-09-01

    Diabetic retinopathy (DR) and diabetic nephropathy (DN) are serious microvascular complications of diabetes mellitus. Correlations between severity of DR and DN and computed heritability estimates for DR were determined in a large, multiethnic sample of diabetic families. The hypothesis was that (1) the severity of DR correlates with the presence and severity of nephropathy in individuals with diabetes mellitus, and (2) the severity of DR is under significant familial influence in members of multiplex diabetic families. The Family Investigation of Nephropathy and Diabetes (FIND) was designed to evaluate the genetic basis of DN in American Indians, European Americans, African Americans, and Mexican Americans. FIND enrolled probands with advanced DN, along with their diabetic siblings who were concordant and discordant for nephropathy. These diabetic family members were invited to participate in the FIND-Eye study to determine whether inherited factors underlie susceptibility to DR and its severity. FIND-Eye participants underwent eye examinations and had fundus photographs taken. The severity of DR was graded by using the Early Treatment Diabetic Retinopathy Study Classification (ETDRS). Sib-sib correlations were calculated with the SAGE 5.0 program FCOR, to estimate heritability of retinopathy severity. This report summarizes the results for the first 2368 diabetic subjects from 767 families enrolled in FIND-Eye; nearly 50% were Mexican American, the largest single ethnicity within FIND. The overall prevalence of DR was high; 33.4% had proliferative DR; 7.5%, 22.8%, and 9.5% had severe, moderate, and mild nonproliferative DR, respectively; 26.6% had no DR. The severity of DR was significantly associated with severity of DN, both by phenotypic category and by increasing serum creatinine concentration (chi(2) = 658.14, df = 20; P FIND-Eye sample. These data confirm that the severity of DR parallels the presence and severity of nephropathy in individuals with diabetes

  11. The interblink interval in normal and dry eye subjects

    Directory of Open Access Journals (Sweden)

    Johnston PR

    2013-02-01

    Full Text Available Patrick R Johnston,1 John Rodriguez,1 Keith J Lane,1 George Ousler,1 Mark B Abelson1,21Ora, Inc, Andover, MA, USA; 2Schepens Eye Research Institute and Harvard Medical School, Boston, MA, USAPurpose: Our aim was to extend the concept of blink patterns from average interblink interval (IBI to other aspects of the distribution of IBI. We hypothesized that this more comprehensive approach would better discriminate between normal and dry eye subjects.Methods: Blinks were captured over 10 minutes for ten normal and ten dry eye subjects while viewing a standardized televised documentary. Fifty-five blinks were analyzed for each of the 20 subjects. Means, standard deviations, and autocorrelation coefficients were calculated utilizing a single random effects model fit to all data points and a diagnostic model was subsequently fit to predict probability of a subject having dry eye based on these parameters.Results: Mean IBI was 5.97 seconds for normal versus 2.56 seconds for dry eye subjects (ratio: 2.33, P = 0.004. IBI variability was 1.56 times higher in normal subjects (P < 0.001, and the autocorrelation was 1.79 times higher in normal subjects (P = 0.044. With regard to the diagnostic power of these measures, mean IBI was the best dry eye versus normal classifier using receiver operating characteristics (0.85 area under curve (AUC, followed by the standard deviation (0.75 AUC, and lastly, the autocorrelation (0.63 AUC. All three predictors combined had an AUC of 0.89. Based on this analysis, cutoffs of ≤3.05 seconds for median IBI, and ≤0.73 for the coefficient of variation were chosen to classify dry eye subjects.Conclusion: (1 IBI was significantly shorter for dry eye patients performing a visual task compared to normals; (2 there was a greater variability of interblink intervals in normal subjects; and (3 these parameters were useful as diagnostic predictors of dry eye disease. The results of this pilot study merit investigation of IBI

  12. Nordic research in ophthalmology

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Zetterström, Charlotta; Ehlers, Niels

    2003-01-01

    Ophthalmology, eye research, cornea, catarcat, paediatric ophthalmology, glaucoma, diabetic eye disease, age-related macular degeneration, ophthalmic oncology......Ophthalmology, eye research, cornea, catarcat, paediatric ophthalmology, glaucoma, diabetic eye disease, age-related macular degeneration, ophthalmic oncology...

  13. Prevalence of dry eye syndrome and diabetic retinopathy in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Afkhami-Ardekani Mohammad

    2008-06-01

    Full Text Available Abstract Background This study was performed to assess the prevalence of dry eye syndrome and diabetic retinopathy (DR in type 2 diabetic patients and their contributing factors. Methods 199 type 2 diabetic patients referred to Yazd Diabetes Research Center were consecutively selected. All Subjects were assessed by questionnaire about other diseases and drugs. Dry eye syndrome was assessed with Tear break up time tests and Schirmer. All the subjects underwent indirect ophthalmoscopy and retinal color photography. DR was graded according to early Treatment Diabetic Retinopathy (ETDRS criteria. Results Of 199 subjects, 108 patients (54.3% suffer from dry eye syndrome. Although dry eye syndrome was more common in older and female patients, this association was not significant. But there was significantly association between dry eye syndrome and duration of diabetes (P = 0.01. Dry eye syndrome was more frequent in diabetic patients with DR (P = 0.02. DR was found in 140 patients (70.35%, which included 34 patients (17.1% with mild non proliferative DR (NPDR, 34 patients (17.1% with moderate NPDR, 22 patients (11.1% with severe NPDR and 25 patients (25.1% with proliferative DR (PDR. There were significant relation between age, sex and duration of diabetes and DR. Conclusion In this study the prevalence of dry eye syndrome was 54.3%. Diabetes and dry eyes appear to have a common association. Further studies need to be undertaken to establish an etiologic relationship. However, examination for dry eye should be an integral part of the assessment of diabetic eye disease.

  14. Analysis of eye health in the Thai population.

    Science.gov (United States)

    Yospaiboon, Yosanan; Yospaiboon, Kasem; Ratanapakorn, Tanapat; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij

    2012-07-01

    To assess national eye health as a baseline for improving medical education, services and research. Information on eye illness among out- and in-patients was based on hospital claims from the three national health insurance schemes in 2010. The data were analyzed by age groups. In 2010, 4,982,025 out-patient visits and 187,080 in-patient admissions were reported. The five most common outpatient eye conditions were disorders of the (1) conjunctiva (H10-H13) (2) eyelid, lacrimal system and orbit (H00-H06) (3) lens (H25-28) (4) sclera, cornea, iris and ciliary body (H15-H22) and (5) glaucoma (H40-H42). The five most common inpatient eye diseases were (1) disorders of lens (H25-H28) (2) conjunctiva (H10-H13) (3) sclera, cornea, iris and ciliary body (H15-H22) (4) choroid and retina (H30-H35) and (5) glaucoma (H40-H42). Information on the most frequent eye diseases-including the types and frequency of high risk conditions, the diseases causing the most impact on vision and resulting in the highest health expenditures-will be used to (a) revise the curricula for medical education (b) to improve eye care services and (c) to improve access to data for research themes tailored to local and national needs.

  15. EVALUATION OF DRY EYES IN DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Anshu Sharma

    2017-12-01

    Full Text Available BACKGROUND According to the National Eye Institute, dry eye is a condition in which the eye does not produce tears properly. It can also involve tears not having the right consistency or evaporating too quickly. Tears are necessary to help maintain moisture on the surface of the eye and for clear vision. Diabetes is often associated with several significant ocular conditions such as retinopathy, refractive changes, cataracts, glaucoma and macular oedema. However, one of the most common ocular complications associated with diabetes is dry eye. The aim of the study is to study the prevalence of dry eyes in diabetes mellitus and to evaluate ocular and other risk factors relevant to diabetic dry eyes. MATERIALS AND METHODS A hospital-based cross-sectional clinical study of 100 diabetic patients who presented to the Department of Ophthalmology, Santosh Medical College and Hospital, Ghaziabad, between January 2016 to June 2017 was conducted. Detailed diabetic history was recorded. Assessment of anterior segment via slit-lamp biomicroscopy was done. The examinations for dry eyes included Schirmer's test, tear breakup time, fluorescein and rose Bengal staining. RESULTS Sixty two (62% diabetic patients had dry eye. The prevalence in type I was 3% and prevalence in type II was 59%. Dry eye prevalence was maximum in those above 40 years of age. Symptoms like reduced corneal sensation (44% and meibomitis (20% were major attributable risk factors. Ocular surface damage was predominantly superficial punctate keratitis. Retinopathy was not statistically associated with the prevalence of dry eyes. CONCLUSION Diabetes and dry eye appears to be a common association. Reduction in the modifiable risk factors of dry eye is essential to reduce its prevalence. No significant statistical correlation was found between retinopathy and dry eyes. However, examination for dry eyes should be an integral part of the assessment of diabetic eye disease.

  16. Effects of anger and sadness on attentional patterns in decision making: an eye-tracking study.

    Science.gov (United States)

    Xing, Cai

    2014-02-01

    Past research examining the effect of anger and sadness on decision making has associated anger with a relatively more heuristic decision-making approach. However, it is unclear whether angry and sad individuals differ while attending to decision-relevant information. An eye-tracking experiment (N=87) was conducted to examine the role of attention in links between emotion and decision making. Angry individuals looked more and earlier toward heuristic cues while making decisions, whereas sad individuals did not show such bias. Implications for designing persuasive messages and studying motivated visual processing were discussed.

  17. Instruction-based clinical eye-tracking study on the visual interpretation of divergence: How do students look at vector field plots?

    Science.gov (United States)

    Klein, P.; Viiri, J.; Mozaffari, S.; Dengel, A.; Kuhn, J.

    2018-06-01

    Relating mathematical concepts to graphical representations is a challenging task for students. In this paper, we introduce two visual strategies to qualitatively interpret the divergence of graphical vector field representations. One strategy is based on the graphical interpretation of partial derivatives, while the other is based on the flux concept. We test the effectiveness of both strategies in an instruction-based eye-tracking study with N =41 physics majors. We found that students' performance improved when both strategies were introduced (74% correct) instead of only one strategy (64% correct), and students performed best when they were free to choose between the two strategies (88% correct). This finding supports the idea of introducing multiple representations of a physical concept to foster student understanding. Relevant eye-tracking measures demonstrate that both strategies imply different visual processing of the vector field plots, therefore reflecting conceptual differences between the strategies. Advanced analysis methods further reveal significant differences in eye movements between the best and worst performing students. For instance, the best students performed predominantly horizontal and vertical saccades, indicating correct interpretation of partial derivatives. They also focused on smaller regions when they balanced positive and negative flux. This mixed-method research leads to new insights into student visual processing of vector field representations, highlights the advantages and limitations of eye-tracking methodologies in this context, and discusses implications for teaching and for future research. The introduction of saccadic direction analysis expands traditional methods, and shows the potential to discover new insights into student understanding and learning difficulties.

  18. Williams syndrome and its cognitive profile: the importance of eye movements

    Directory of Open Access Journals (Sweden)

    Van Herwegen J

    2015-06-01

    Full Text Available Jo Van Herwegen Department of Psychology, Kingston University London, Surrey, UK Abstract: People with Williams syndrome (WS, a rare neurodevelopmental disorder that is caused by a deletion on the long arm of chromosome 7, often show an uneven cognitive profile with participants performing better on language and face recognition tasks, in contrast to visuospatial and number tasks. Recent studies have shown that this specific cognitive profile in WS is a result of atypical developmental processes that interact with and affect brain development from infancy onward. Using examples from language, face processing, number, and visuospatial studies, this review evaluates current evidence from eye-tracking and developmental studies and argues that domain general processes, such as the ability to plan or execute saccades, influence the development of these domain-specific outcomes. Although more research on eye movements in WS is required, the importance of eye movements for cognitive development suggests a possible intervention pathway to improve cognitive abilities in this population. Keywords: Williams syndrome, eye movements, face processing, language, number, visuospatial abilities

  19. Association for Research in Vision and Ophthalmology (ARVO)--2010 Annual Meeting. For Sight: The Future of Eye and Vision Research--part 2.

    Science.gov (United States)

    Hookes, Livia

    2010-07-01

    The 2010 Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO), held in Fort Lauderdale, FL, USA, included topics covering new therapeutic developments in the field of eye and vision research. This conference report highlights selected presentations on the development of OT-440 (Othera Pharmaceuticals Inc) for the potential treatment of glaucoma, an extended-release implant of brimonidine (pSivida Corp) for ocular hypertension, AR-12286 (Aerie Pharmaceuticals Inc) for ocular hypertension or glaucoma, AC-8 (Calmune Corp/RiboVax Biotechnologies SA) for ocular diseases following HSV infection, and fidarestat (Sanwa Kagaku Kenkyusho Co Ltd) and the recombinant proteins NOV and NOVCter (INSERM/University Rene Descartes) for corneal neovascularization.

  20. Dry Eye Disease Incidence Associated with Chronic Graft-Host Disease: Nonconcurrent Cohort Study (An American Ophthalmological Society Thesis)

    Science.gov (United States)

    Mian, Shahzad I.; De la Parra-Colín, Paola; De Melo-Franco, Rafael; Johnson, Christopher; Barrientos-Gutierrez, Tonatiuh

    2015-01-01

    Purpose: To determine if chronic graft-versus-host disease (cGVHD) after allogeneic hematopoietic stem cell transplantation (HSCT) is associated with stable or progressive dry eye disease and to determine the true incidence in patients with no prior history of dry eye disease. Methods: A nonconcurrent cohort study at a single institution with 136 patients who had no previous history of dry eye disease before HSCT. Survival analysis was used to estimate dry eye disease incidence. The incidence rate was calculated using life tables as the number of observed dry eye disease cases divided by the person-time at risk accumulated by the cohort. Transition probabilities were calculated from time of transplant to time of diagnosis, and then to last recorded visit. Results: Incidence rate was 0.8 cases of dry eye disease per person-year, and half of the population at risk developed dry eye disease during the first 10 months post transplant. Time to develop dry eye disease was 2.5 months for mild dry eye disease, 9.6 months for moderate dry eye disease, and 13.2 months for severe dry eye disease. In terms of cumulative incidence, 73% of subjects developed dry eye disease (50% mild, 16% moderate, and 7% severe) at the time of diagnosis. Conclusions: Our findings suggest that dry eye disease associated with cGVHD is an extremely frequent event and shows a wide spectrum of severity, with a mild form presenting early and a moderate to severe form presenting later after HSCT. These findings need to be studied further to elucidate if these are two different pathophysiological entities or just different expressions of the same pathology. PMID:27507907

  1. Feasibility study on retinal vascular bypass surgery in isolated arterially perfused caprine eye model

    Science.gov (United States)

    Chen, Y; Wu, W; Zhang, X; Fan, W; Shen, L

    2011-01-01

    Purpose To investigate the feasibility of bypassing occluded segments of retinal venous main vessels in isolated, arterially perfused caprine eyes via the closed-sky vitrectomy approach using keratoprosthesis. Methods Isolated caprine eyes were used in this study. For each eye, the retinal vessel was perfused by Krebs solution via ophthalmic artery, and pars plana vitrectomy was performed using temporary keratoprosthesis. All retinal micro-vascular maneuvers were performed in a closed-sky eyeball. The main retinal vein was blocked by endodiathermy at the site of the vessel's first branching. Two openings, several millimeters apart, were created by vascular punctures in both the main vein and its branch vein wall straddling the induced occluded segment. Catheterization was achieved using a flexible polyimide tube, with each end inserted into the vessel wall opening. A sealed connection between the vessel and the tube was obtained by endodiathermy. Bypass of the occluded retinal vein segment was thus achieved, and the patency of this vascular bypass was confirmed by intravascular staining. Results Puncturing, catheterization, and endodiathermy were viable by closed-sky approach using keratoprosthesis. Bypassing of the occluded retinal main vein segment was accomplished with the combination of these maneuvers. Good results were obtained in 23 of 38 (60%) caprine eyes. Conclusions This study demonstrated that bypassing the occluded segment of retinal main vein can be successfully performed in a closed-sky eyeball model of isolated, arterially perfused caprine eye. This early work indicated that the more advanced retinal vascular bypass surgery in in vivo eye may be feasible in the future. PMID:21921946

  2. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  3. The eyes have it: Using eye tracking to inform information processing strategies in multi-attributes choices.

    Science.gov (United States)

    Ryan, Mandy; Krucien, Nicolas; Hermens, Frouke

    2018-04-01

    Although choice experiments (CEs) are widely applied in economics to study choice behaviour, understanding of how individuals process attribute information remains limited. We show how eye-tracking methods can provide insight into how decisions are made. Participants completed a CE, while their eye movements were recorded. Results show that although the information presented guided participants' decisions, there were also several processing biases at work. Evidence was found of (a) top-to-bottom, (b) left-to-right, and (c) first-to-last order biases. Experimental factors-whether attributes are defined as "best" or "worst," choice task complexity, and attribute ordering-also influence information processing. How individuals visually process attribute information was shown to be related to their choices. Implications for the design and analysis of CEs and future research are discussed. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  5. Study of wavefront aberration in DR patients with different degree of dry eye

    Directory of Open Access Journals (Sweden)

    Jin-Ran Fang

    2018-05-01

    Full Text Available AIM: To compare the changes of wavefront aberrations in patients with diabetic retinopathy(DRand with different degrees of dry eye and to explore the reasons of visual quality decline in them. METHODS: We randomly selected 40 eyes in our hospital for treatment with DR and varying degrees of dry eye, and 40 eyes of normal control group. Topcon KR-1W visual quality analyzer was used to record the mean square the total high order corneal aberration, spherical aberration, comatic aberration and trefoil aberration of cornea with pupil diameters of 4mm and 6mm. Analysis of variance were used to compare the wavefront aberrations and the aberration values in the control group and in patients with diabetic retinopathy and with different degrees of dry eye. RESULTS: For 4mm and 6mm pupil diameters, nondiabetic retinopathy(NDRwith dry eye group, the nonproliferative diabetic retinopathy(NPDRwith dry eye group and proliferative diabetic retinopathy(PDRdry eye group had significantly increased tHOA, coma and trefoil compared with the contrast group(PPCONCLUSION: Dry eye of diabetic retinopathy with different degrees is closely related to the increase of wavefront aberration. Increased wavefront aberration may be one of the reasons to reduced visual quality in patients with diabetic retinopathy and with dry eye, and provide the basis for the decline of visual function of diabetic patients with dry eye.

  6. Eye Care Quality and Accessibility Improvement in the Community (EQUALITY) for adults at risk for glaucoma: study rationale and design.

    Science.gov (United States)

    Owsley, Cynthia; Rhodes, Lindsay A; McGwin, Gerald; Mennemeyer, Stephen T; Bregantini, Mary; Patel, Nita; Wiley, Demond M; LaRussa, Frank; Box, Dan; Saaddine, Jinan; Crews, John E; Girkin, Christopher A

    2015-11-18

    Primary open angle glaucoma is a chronic, progressive eye disease that is the leading cause of blindness among African Americans. Glaucoma progresses more rapidly and appears about 10 years earlier in African Americans as compared to whites. African Americans are also less likely to receive comprehensive eye care when glaucoma could be detected before irreversible blindness. Screening and follow-up protocols for managing glaucoma recommended by eye-care professional organizations are often not followed by primary eye-care providers, both ophthalmologists and optometrists. There is a pressing need to improve both the accessibility and quality of glaucoma care for African Americans. Telemedicine may be an effective solution for improving management and diagnosis of glaucoma because it depends on ocular imaging and tests that can be electronically transmitted to remote reading centers where tertiary care specialists can examine the results. We describe the Eye Care Quality and Accessibility Improvement in the Community project (EQUALITY), set to evaluate a teleglaucoma program deployed in retail-based primary eye care practices serving communities with a large percentage of African Americans. We conducted an observational, 1-year prospective study based in two Walmart Vision Centers in Alabama staffed by primary care optometrists. EQUALITY focuses on new or existing adult patients who are at-risk for glaucoma or already diagnosed with glaucoma. Patients receive dilated comprehensive examinations and diagnostic testing for glaucoma, followed by the optometrist's diagnosis and a preliminary management plan. Results are transmitted to a glaucoma reading center where ophthalmologists who completed fellowship training in glaucoma review results and provide feedback to the optometrist, who manages the care of the patient. Patients also receive eye health education about glaucoma and comprehensive eye care. Research questions include diagnostic and management agreement

  7. Study On Technology Based Home Vision Screening And Creating Awareness On Eye Health

    Directory of Open Access Journals (Sweden)

    Nirav Mehta

    2015-08-01

    Full Text Available Introduction Technology is one of most important factor in todays life. IPAD is leading as people can make use of technology by just pressing buttons. Networking technology and education makes communication easier and helps people in easy education and awareness. Aim amp objectives The main aim of the study is to educate and aware among people regarding eye health and the check the visual function of their eye by using Apple I pad. Material and Methodology The following study is a home based vision screening program using IPAD which uses the basic tests like visual acuity color vision contrast sensitivity and amsler tests for checking the basic functions of the eye. The study was performed in many societies moving from one place to another using IPAD as a tool. Reliability of ipad was checked a pilot study on 25 subjects visual acuity colour vision and contrast sensitivity was taken on both ipad and Original chart like snellen ishihara and pellirobson and compared in which the results and the accuracy were same. The study also contains questionnaire on the awareness and education about eye health. The subjects included in the study were an age group of 10 to 70. Subjects like infants and blind were not included in the study. Results During the study it was observed that there is no significant difference in testing of visual acuity between ipad and Snellen standard chart. The subjects responded actively towards screening and that home vision screening can be possible. During the study it was found that 40 subjects out of 100 needed further detailed check-up and were referred in Rotary eye hospital hospital but only 3 out of 40 came for it. This shows that they are less aware and education about their eye health. Software used in IPAD were visual acuity color vision contrast sensitivity and amsler tests A questionnaire was also asked which indicated less awareness among the common people. Conclusion We examined with just an ipad and not an

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  9. A PROSPECTIVE OBSERVATIONAL STUDY REGARDING PREVALENCE OF DRY EYE DISEASE IN POST-OPERATIVE CATARACT SURGERY PATIENTS OF 140 CASES.

    Directory of Open Access Journals (Sweden)

    S. Srinivasan

    2017-02-01

    Full Text Available BACKGROUND Dry eye disease is one of the most common ocular surface disorder with large number of studies carried out in various countries estimate the prevalence of dry eye disease to be between 5-34%. The prevalence of dry eye increases with age. As per Breaver Dam study regarding dry eye the prevalence of DED 13.3%. Dry eye was apparently higher in women than men. Studies have shown that cataract surgery worsen dry eye symptoms in patients with preexisting dry eye symptoms as well as without preexisting DES, mostly dry eye symptoms last for two months of post cataract surgery period. MATERIALS AND METHODS The prospective observational study was conducted in Department of Ophthalmology, Government Vellore Medical College and Hospital, Vellore. The total number of cataract surgery performed cases were 140 in number. The study period was four months, conducted in tertiary eye center. The Cataract patients were preoperatively at normal tear secretions. Post cataract surgery period from first POD, one week POD, four weeks, six weeks, two months and three months POD examined by slit lamp, Schirmer's test I, TBUT and corneal sensitivity test were performed. RESULTS Our study revealed that increased prevalence in female sex with increased age group range from 51-70 years showed post cataract surgery period dryness of eye. The ratio of Post cataract surgery DED in male and female is 13:29. This shows increased female sex prevalence of postoperative DED. In our study, the prevalence of post cataract surgery dry eye disease was 30%. CONCLUSION 73% cataract surgeries is now clear corneal cataract surgery and this procedure cuts a large part of corneal nerves. The nerve essential for tear production gets disturbed leading to dryness and hence decreased visual function. The corneal nerves are important in self-regulation of tears since they provide the sensation in the feedback loop that signals tear production. When the functions of the nerves get blocked

  10. Nutrition and Age-Related Eye Diseases: The ALIENOR (Antioxydants, Lipides Essentiels, Nutrition et Maladies Oculaires) Study.

    OpenAIRE

    Delcourt , Cécile; Korobelnik , Jean-François; Barberger-Gateau , Pascale; Delyfer , Marie-Noëlle; Marie-Bénédicte , Rougier; Le Goff , Mélanie; Malet , Florence; Joseph , Colin; Dartigues , Jean-François

    2010-01-01

    International audience; Background: Worldwide, degenerative eye diseases (age-related maculopathy (ARM), cataract, glaucoma) are the main causes of visual impairment and blindness, which contribute to disability in the elderly. Mainly three types of nutritional factors are investigated for their potential protection against eye ageing: antioxidants; lutein and zeaxanthin (carotenoids which accumulate specifically in the eye); omega 3 polyunsaturated fatty acids. Few epidemiological studies ha...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  12. The Prospective Health Assessment of Cataract Patients’ Ocular Surface (PHACO study: the effect of dry eye

    Directory of Open Access Journals (Sweden)

    Trattler WB

    2017-08-01

    Full Text Available William B Trattler,1 Parag A Majmudar,2 Eric D Donnenfeld,3 Marguerite B McDonald,4 Karl G Stonecipher,5 Damien F Goldberg6 On behalf of the PHACO Study Group 1Center for Excellence in Eye Care, Miami, FL, USA; 2Chicago Cornea Consultants, Chicago, IL, USA; 3Ophthalmic Consultants of Long Island, Garden City, NY, USA; 4Ophthalmic Consultants of Long Island, Lynbrook, NY, USA; 5University North Carolina School of Medicine, Chapel Hill, NC, USA; 6Wolstan & Goldberg Eye Associates, Torrance, CA, USA Purpose: To determine the incidence and severity of dry eye as determined by the International Task Force (ITF scale in patients being screened for cataract surgery.Patients and methods: This was a prospective, multi-center, observational study of 136 patients, at least 55 years of age, who were scheduled to undergo cataract surgery. The primary outcome measure was the incidence of dry eye as evaluated by grade on the ITF scale and secondary outcome measures include tear break-up time (TBUT, ocular surface disease index score, corneal staining with fluorescein, conjunctival staining with lissamine green, and a patient questionnaire to evaluate symptoms of dry eye.Results: Mean patient age was 70.7 years. A total of 73.5% of patients were Caucasian and 50% were female. Almost 60% had never complained of a foreign body sensation; only 13% complained of a foreign body sensation half or most of the time. The majority of patients (62.9% had a TBUT ≤5 seconds, 77% of eyes had positive corneal staining and 50% of the eyes had positive central corneal staining. Eighteen percent had Schirmer’s score with anesthesia ≤5 mm.Conclusion: The incidence of dry eye in patients scheduled to undergo cataract surgery in a real-world setting is higher than anticipated. Keywords: cataract surgery screening, dry eye, International Task Force scale, observational study

  13. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  14. Eye tracking in Library and Information Science

    DEFF Research Database (Denmark)

    Lund, Haakon

    2016-01-01

    Purpose The purpose of this paper is to present a systematic literature review of the application of eye-tracking technology within the field of library and information science. Eye-tracking technology has now reached a level of maturity, which makes the use of the technology more accessible....... Subsequently, a growing interest in employing eye tracking as a methodology within library and information science research must be anticipated. Design/methodology/approach The review follows the guidelines set in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses recommendations. Two...... reference databases are searched for relevant references: Library and Information Science Abstracts and Library, Information Science and Technology Abstracts. The main selection criteria are peer-reviewed literature that describes the experimental setting, including which eye-tracking equipment was used...

  15. 'An eye, for eyes - mission' - From dream to reality

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2013-10-01

    Full Text Available Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global shortage of donor corneas [2]. At this juncture Yokoo et al isolated and expanded corneal endothelial precursors using the sphere forming assay in vitro [3] and demonstrated the in vivo transplantation of these corneal endothelial precursors in a rabbit model of bullous keratopathy [4]. Following this, we studied the transportation of cadaver donor derived corneal endothelial tissue (CET from human cadaver donors in a thermoreversible gelation polymer (TGP (4 based transportation cocktail without cool preservation and demonstrated the viability of human corneal endothelial precursor (HCEP cells isolated from these CETs even after 72 hours of transportation without cool preservation [5]. This was done to suit the conditions existing in developing nations like India where hospitals might be located far from eye banks and maintaining cold chain preservation is relatively difficult. Further, these HCEPs were expanded in vitro using a polymer based expansion protocol [5]. This was the first step in the realisation of the dream of 'Eye for eyes' in a manner suitable for Indian conditions. Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global

  16. Study of the structure of buffalo's eye lens and scleroretinal rim in Tabriz by ultrasonography

    Directory of Open Access Journals (Sweden)

    GH Assadnassab

    2011-05-01

    Full Text Available In this study, ultrasonographic condition of lens and posterior wall of buffalo's eye in Tabriz area were investigated due to their important role in vision and also measurements were made in anterior-posterior axial B-mode display methods. The ultrasonographic images were similar to the images obtained from other particularly the cow. Total thickness of the lens was 1.133 ± 0.052 cm with the thickness being 1.135 ± 0.052 cm in the right eye and 1.132 ± 0.053 cm in the left eye. Thickness of the posterior wall of the right and left eyes were 1.677 ± 0.042 mm and 1.672 ± 0.041 mm respectively with the total thickness of the posterior wall measuring 1.674 ± 0.040 mm. There was no significant difference between the left and right eyes regarding these parameters.

  17. The influence of protein free calf blood extract eye gel on dry eye after pterygium surgery

    Directory of Open Access Journals (Sweden)

    Cai-Ni Ji

    2013-07-01

    Full Text Available AIM: To investigate the influence of protein free calf blood extract eye gel on dry eye after pterygium surgery. METHODS: Thirty six patients(40 eyeswith primary nasal pterygium were enrolled in this study, which were divided into study group and control group randomly, with 20 eyes in each group. All patients received pterygium excision and limbal stem cell autograft surgery and tobramicin dexamethasone eye drops after surgery. Patients of the study group received protein free calf blood extract eye gel while those of the control group received 0.1% sodium hyaluronate eye drops furthermore. Ocular surface disease index(OSDIquestionnaire, tear film break-up time(BUTand Schirmer's Ⅰ test Ⅰ(SⅠtwere carried before and 3 months after surgery to evaluate the dry eye degree of the patients. RESULTS: There was no statistical difference between the age, gender and size of the pterygium of the study and control groups preoperatively. There was no statistical difference between the OSDI(2.33±1.02 vs 2.32±0.93, BUT(8.80±2.48 vs 8.35±2.28seconds and SⅠt(4.30±2.30 vs 4.40±2.44of the two groups preoperatively. There was statistical difference between the OSDI(1.45±0.47 vs 1.81±0.60, BUT(11.20±2.07 vs 9.50±2.40seconds and SⅠt(8.35±3.13 vs 6.35±2.18of the two groups 3 months postoperatively, which was also different from that of the preoperative data correspondingly. CONCLUSION: Protein free calf blood extract eye gel could reduce the dry eye after pterygium surgery.

  18. iTemplate: A template-based eye movement data analysis approach.

    Science.gov (United States)

    Xiao, Naiqi G; Lee, Kang

    2018-02-08

    Current eye movement data analysis methods rely on defining areas of interest (AOIs). Due to the fact that AOIs are created and modified manually, variances in their size, shape, and location are unavoidable. These variances affect not only the consistency of the AOI definitions, but also the validity of the eye movement analyses based on the AOIs. To reduce the variances in AOI creation and modification and achieve a procedure to process eye movement data with high precision and efficiency, we propose a template-based eye movement data analysis method. Using a linear transformation algorithm, this method registers the eye movement data from each individual stimulus to a template. Thus, users only need to create one set of AOIs for the template in order to analyze eye movement data, rather than creating a unique set of AOIs for all individual stimuli. This change greatly reduces the error caused by the variance from manually created AOIs and boosts the efficiency of the data analysis. Furthermore, this method can help researchers prepare eye movement data for some advanced analysis approaches, such as iMap. We have developed software (iTemplate) with a graphic user interface to make this analysis method available to researchers.

  19. Instructional Suggestions Supporting Science Learning in Digital Environments Based on a Review of Eye-Tracking Studies

    Science.gov (United States)

    Yang, Fang-Ying; Tsai, Meng-Jung; Chiou, Guo-Li; Lee, Silvia Wen-Yu; Chang, Cheng-Chieh; Chen, Li-Ling

    2018-01-01

    The main purpose of this study was to provide instructional suggestions for supporting science learning in digital environments based on a review of eye tracking studies in e-learning related areas. Thirty-three eye-tracking studies from 2005 to 2014 were selected from the Social Science Citation Index (SSCI) database for review. Through a…

  20. Dry eye in the beaver dam offspring study: prevalence, risk factors, and health-related quality of life.

    Science.gov (United States)

    Paulsen, Adam J; Cruickshanks, Karen J; Fischer, Mary E; Huang, Guan-Hua; Klein, Barbara E K; Klein, Ronald; Dalton, Dayna S

    2014-04-01

    To estimate dry eye prevalence in the Beaver Dam Offspring Study (BOSS), including a young adult population, and investigate associated risk factors and impact on health-related quality of life. Cohort study. The BOSS (2005-2008) is a study of aging in the adult offspring of the population-based Epidemiology of Hearing Loss Study cohort. Questionnaire data on health history, medication use, risk factors, and quality of life were available for 3275 participants. Dry eye was determined by self-report of frequency of symptoms and the intensity of those symptoms. Associations between dry eye and risk factors were analyzed using logistic regression. The prevalence of dry eye in the BOSS was 14.5%: 17.9% of women and 10.5% of men. In a multivariate model, statistically significant associations were found with female sex (odds ratio [OR], 1.68; 95% confidence interval [CI], 1.33-2.11), current contact lens use (OR, 2.01; 95% CI, 1.53-2.64), allergies (OR, 1.59; 95% CI, 1.22-2.08), arthritis (OR, 1.44; 95% CI, 1.12-1.85), thyroid disease (OR, 1.43; 95% CI, 1.02-1.99), antihistamine use (OR, 1.54; 95% CI, 1.18-2.02), and steroid use (OR, 1.54; 95% CI, 1.16-2.06). Dry eye was also associated with lower scores on the Medical Outcomes Study Short Form 36 (β = -3.9, P < .0001) as well as on the National Eye Institute 25-Item Visual Function Questionnaire (NEI VFQ-25) (β = -3.4, P < .0001) when controlling for age, sex, and comorbid conditions. The prevalence of dry eye and its associated risk factors in the BOSS were similar to previous studies. In this study, dry eye was associated with lower quality of life on a health-related quality-of-life instrument and the vision-specific NEI VFQ-25. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Numerical Analysis on Color Preference and Visual Comfort from Eye Tracking Technique

    Directory of Open Access Journals (Sweden)

    Ming-Chung Ho

    2015-01-01

    Full Text Available Color preferences in engineering are very important, and there exists relationship between color preference and visual comfort. In this study, there are thirty university students who participated in the experiment, supplemented by pre- and posttest questionnaires, which lasted about an hour. The main purpose of this study is to explore the visual effects of different color assignment with subjective color preferences via eye tracking technology. Eye-movement data through a nonlinear analysis detect slight differences in color preferences and visual comfort, suggesting effective physiological indicators as extensive future research discussed. Results found that the average pupil size of eye-movement indicators can effectively reflect the differences of color preferences and visual comfort. This study more confirmed that the subjective feeling will make people have misjudgment.

  2. Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.

    Science.gov (United States)

    Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K

    2010-02-01

    Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.

  3. The eyes don't have it: lie detection and Neuro-Linguistic Programming.

    Directory of Open Access Journals (Sweden)

    Richard Wiseman

    Full Text Available Proponents of Neuro-Linguistic Programming (NLP claim that certain eye-movements are reliable indicators of lying. According to this notion, a person looking up to their right suggests a lie whereas looking up to their left is indicative of truth telling. Despite widespread belief in this claim, no previous research has examined its validity. In Study 1 the eye movements of participants who were lying or telling the truth were coded, but did not match the NLP patterning. In Study 2 one group of participants were told about the NLP eye-movement hypothesis whilst a second control group were not. Both groups then undertook a lie detection test. No significant differences emerged between the two groups. Study 3 involved coding the eye movements of both liars and truth tellers taking part in high profile press conferences. Once again, no significant differences were discovered. Taken together the results of the three studies fail to support the claims of NLP. The theoretical and practical implications of these findings are discussed.

  4. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  5. Computational Models of the Eye and their Applications in Long Duration Space Flight

    Science.gov (United States)

    Chen, Richard; Best, Lauren; Mason, Kyle; Mulugeta, Lealem

    2011-01-01

    Astronauts are exposed to cephalad fluid shift, increased carbon dioxide levels and other environmental factors during space flight. As a result of these conditions, it is believed that they are at risk of developing increased intracranial pressure (ICP) and intraocular pressure (IOP), which in turn may cause papilledema and other disorders of the eye that can lead to temporary or permanent changes in vision. However, the mechanisms behind this risk are not fully understood. Ground analog and flight studies pose challenges because there are limited non-invasive methods that can be used to study the eye and intracranial space. Therefore it is proposed that computational models can be applied to help address this gap by providing a low cost method for studying the effects of IOP, ICP and various properties of the eye on these diseases. The information presented by the authors provides a summary of several models found in literature that could potentially be augmented and applied to inform research. Specifically, finite element models of the optic nerve head, sclera and other structures of the eye can be readily adapted as potential building blocks. These models may also be integrated with a brain/cerebrospinal fluid (CSF) model which will take into account the interaction between the CSF fluid and its pressure on the optic nerve. This integration can enable the study of the effects of microgravity on the interaction between the vasculature system and CSF system and can determine the effects of these changes on the optic nerve, and in turn the eye. Ultimately, it can help pinpoint the influences of long-term exposure to microgravity on vision and inform the future research into countermeasure development. In addition to spaceflight, these models can provide deeper understanding of the mechanisms of glaucoma, papilledema and other eye disorders observed in terrestrial conditions.

  6. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen

    2011-01-01

    Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  7. Perceptions of eye health in schools in Pakistan

    Directory of Open Access Journals (Sweden)

    Qureshi Mohammad

    2006-03-01

    Full Text Available Abstract Background Research exploring children's and their teachers' perceptions of eye health is lacking. This paper reports for the first time on perceptions of primary schoolchildren and their teachers of healthy and diseased eyes, things that keep eyes healthy and damage them, and what actions to be taken in case of an eye injury. Methods Using draw and write technique, 160 boys and girls (9–12 years old attending four primary schools in Abbottabad district, northern Pakistan, were invited to draw pictures in response to a set of semi-structured questions and then label them. Sixteen teachers who were currently teaching the selected students were interviewed one-on-one. Results Analysis of text accompanying 800 drawings and of the interview scripts revealed that most children and teachers perceived healthy eyes to be those which could see well, and diseased eyes to be those which have redness, watering, dirty discharge, pain, and itching; or those which have "weak eyesight" and blindness. Among things that students and teachers thought damage the eyes included sun, television, and sharp pointed objects, particularly pencils. Teachers noted that children with eye problems "have difficulty seeing the blackboard well", "screw up their eyes", and "hold their books too close". Conclusion We conclude that schoolchildren and their teachers had a good knowledge of eye health, but many of them had serious misconceptions e.g., use of kohl, medicines and eye drops keeps eyes healthy. Kohl is an important source of lead and can reduce children's intelligence even at low blood levels. Health education in schools must take into account children's existing knowledge of and misconceptions about various aspects of eye health. Such steps if taken could improve the relevance of eye health education to schoolchildren.

  8. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  9. Survey of eye practitioners' preference of diagnostic tests and treatment modalities for dry eye in Ghana.

    Science.gov (United States)

    Asiedu, Kofi; Kyei, Samuel; Ayobi, Benedict; Agyemang, Frank Okyere; Ablordeppey, Reynolds Kwame

    2016-12-01

    This study sought to provide an evidence-based profile of the diagnosis, treatment and knowledge or opinions on dry eye among optometrists and ophthalmologists in Ghana. This was a cross-sectional survey RESULTS: The responses of 162 participants are included in the analysis. The most commonly used test to diagnosed dry eye disease was tear break-up time followed by patient history. The most common symptom doctors heard from dry eye patients were burning sensation followed by foreign body sensation. The most often prescribed first- line treatment for dry eye was aqueous-based artificial tears followed by lipid-based artificial tears. Most practitioners considered meibomian gland dysfunction as the most common cause of dry eye followed by pterygium. The most often used test to guide or gauge therapeutic effect is patient history followed closely by tear break-up time. Most practitioners reported that 10%-20% of all their patients they see in a day are diagnosed of dry eye. This study showed tear break up time was the main test majority of practitioners in Ghana used to diagnose dry eye but patient history was the main test used to gauge therapeutic effect over time. Burning sensation was the commonest symptom practitioners heard from dry eye patients whilst artificial tears was their main and first-line treatment for dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  10. A clinical study on "Computer vision syndrome" and its management with Triphala eye drops and Saptamrita Lauha.

    Science.gov (United States)

    Gangamma, M P; Poonam; Rajagopala, Manjusha

    2010-04-01

    American Optometric Association (AOA) defines computer vision syndrome (CVS) as "Complex of eye and vision problems related to near work, which are experienced during or related to computer use". Most studies indicate that Video Display Terminal (VDT) operators report more eye related problems than non-VDT office workers. The causes for the inefficiencies and the visual symptoms are a combination of individual visual problems and poor office ergonomics. In this clinical study on "CVS", 151 patients were registered, out of whom 141 completed the treatment. In Group A, 45 patients had been prescribed Triphala eye drops; in Group B, 53 patients had been prescribed the Triphala eye drops and SaptamritaLauha tablets internally, and in Group C, 43 patients had been prescribed the placebo eye drops and placebo tablets. In total, marked improvement was observed in 48.89, 54.71 and 06.98% patients in groups A, B and C, respectively.

  11. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  12. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  13. Use of traditional eye medicine and self-medication in rural India: A population-based study.

    Science.gov (United States)

    Gupta, Noopur; Vashist, Praveen; Tandon, Radhika; Gupta, Sanjeev K; Kalaivani, Mani; Dwivedi, S N

    2017-01-01

    To determine the type and nature of traditional eye medicine (TEM), their sources and use and practices related to self-medication for ophthalmic diseases in a rural Indian population. A population-based, cross-sectional study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India as part of CORE (Cornea Opacity Rural Epidemiological) study. In addition to comprehensive ophthalmic examination, health-seeking behavior and use of self-medication and TEM was assessed in the adult population using a semi-structured questionnaire. Physical verification of available ophthalmic medications in the enumerated households was conducted by the study team. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for use of self-medication and TEM. Of the 2160 participants interviewed, 396 (18.2%) reported using ophthalmic medications without consulting an ophthalmologist, mainly for symptoms like watering (37.1%), redness (27.7%), itching (19.2%) and infection (13.6%). On physical verification of available eye drops that were being used without prescription, 26.4% participants were practicing self-medication. Steroid, expired/unlabeled and indigenous eye drops were being used by 151(26.5%), 120(21.1%) and 75 (13.2%) participants respectively. Additionally, 25.7% (529) participants resorted to home remedies like 'kajal'(61.4%), honey (31.4%), ghee (11.7%) and rose water (9.1%). Use of TEM is prevalent in this population. The rampant use of steroid eye drops without prescription along with use of expired or unlabelled eye drops warrants greater emphasis on safe eye care practices in this population. Public awareness and regulatory legislations must be implemented to decrease harmful effects arising due to such practices.

  14. An eye movement study for identification of suitable font characters for presentation on a computer screen.

    Science.gov (United States)

    Banerjee, Jayeeta; Majumdar, Dhurjati; Majumdar, Deepti; Pal, Madhu Sudan

    2010-06-01

    We are experiencing a shifting of media: from the printed paper to the computer screen. This transition is modifying the process of how we read and understand a text. It is very difficult to conclude on suitability of font characters based upon subjective evaluation method only. Present study evaluates the effect of font type on human cognitive workload during perception of individual alphabets on a computer screen. Twenty six young subjects volunteered for this study. Here, subjects have been shown individual characters of different font types and their eye movements have been recorded. A binocular eye movement recorder was used for eye movement recording. The results showed that different eye movement parameters such as pupil diameter, number of fixations, fixation duration were less for font type Verdana. The present study recommends the use of font type Verdana for presentation of individual alphabets on various electronic displays in order to reduce cognitive workload.

  15. Prevalence and risk factors associated with dry eye symptoms: a population based study in Indonesia

    Science.gov (United States)

    Lee, A J; Lee, J; Saw, S-M; Gazzard, G; Koh, D; Widjaja, D; Tan, D T H

    2002-01-01

    Aim: To determine the prevalence and identify associated risk factors for dry eye syndrome in a population in Sumatra, Indonesia. Methods: A one stage cluster sampling procedure was conducted to randomly select 100 households in each of the five rural villages and one provincial town of the Riau province, Indonesia, from April to June 2001. Interviewers collected demographic, lifestyle, and medical data from 1058 participants aged 21 years or over. Symptoms of dry eye were assessed using a six item validated questionnaire. Presence of one or more of the six dry eye symptoms often or all the time was analysed. Presence of pterygium was documented. Results: Prevalence of one or more of the six dry eye symptoms often or all the time adjusted for age was 27.5% (95% confidence interval (CI) 24.8 to 30.2). After adjusting for all significant variables, independent risk factors for dry eye were pterygium (p<0.001, multivariate odds ratio (OR) 1.8; 95% CI 1.4 to 2.5) and a history of current cigarette smoking (p=0.05, multivariate OR 1.5; 95% CI 1.0 to 2.2). Conclusions: This population based study provides prevalence rates of dry eye symptoms in a tropical developing nation. From our findings, pterygium is a possible independent risk factor for dry eye symptoms. PMID:12446361

  16. Visual acuity, self-reported vision and falls in the EPIC-Norfolk Eye study

    OpenAIRE

    Yip, Jennifer L Y; Khawaja, Anthony P; Broadway, David; Luben, Robert; Hayat, Shabina; Dalzell, Nichola; Bhaniani, Amit; Wareham, Nicholas; Khaw, Kay-Tee; Foster, Paul J

    2013-01-01

    Purpose To examine the relationship between visual acuity (VA) and self-reported vision (SRV) in relation to falls in 8317 participants of the European Prospective Investigation into Cancer-Norfolk Eye study. Methods All participants completed a health questionnaire that included a question regarding SRV and questions regarding the number of falls in the past year. Distance VA was measured using a logMAR chart for each eye. Poor SRV was defined as those reporting fair or poor distance vision....

  17. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  18. Eye-closure increases children’s memory accuracy for visual material

    Directory of Open Access Journals (Sweden)

    Serena eMastroberardino

    2014-03-01

    Full Text Available Research shows that closing the eyes during retrieval can help both adults and children to remember more about witnessed events. In this study, we investigated whether the eye-closure effect in children is explained by general cognitive load, modality-specific interference, or a combination. 120 children (60 female aged between 8 and 11 years viewed a 5-minute clip depicting a theft and were questioned about the event. During the cued-recall interview, children either viewed a blank screen (blank-screen condition, kept their eyes closed (eye-closure condition, were exposed to visual stimuli (visual-distraction condition, or were exposed to auditory stimuli (auditory-distraction condition. Children in the blank-screen and eye-closure conditions provided significantly more correct and fewer incorrect responses about visual details than children in the visual- and auditory-distraction conditions. No advantage was found for auditory details. These results support neither a pure cognitive-load explanation (in which the effect is expected to be observed for recall of both visual and auditory details, nor a pure modality-specific account (in which recall of visual details should only be disrupted by visual distractions. Practical implications of the findings are discussed.

  19. Effects of Watching Eyes and Norm Cues on Charitable Giving in a Surreptitious Behavioral Experiment

    Directory of Open Access Journals (Sweden)

    Moe Fathi

    2014-04-01

    Full Text Available A series of experimental studies by multiple groups of researchers have found that displaying images of watching eyes causes people to behave more prosocially. It is not yet clear whether watching eyes increase prosocial motivation per se, or whether they simply make people's behavior more normative. Here, we report results from a surreptitious behavioral experiment examining the impacts of watching eye images and cues to local norms on charitable donations in a controlled setting. Eye images significantly increased average donations. Eye images did not make people conform more closely to the apparent norm overall. Instead, there were different patterns according to the apparent norm. For an apparent norm of small donations, eye images made many participants more generous than the norm. For an apparent norm of large donations, there was an excess of participants giving zero in the no-eyes treatment, which was abolished in the eyes treatment. Our results can be explained by a combination of watching eyes increasing prosocial motivation and reluctance to leave a donation visibly less generous than the norm.

  20. Clinical Study on the Eye Changes in the Goiter Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ku, In Soo; Lee, Jung Sang; Lee, Kyung Ja; Choi, Kuen Chul; Ahn, Soo Byuk; Lee, Chang Kyu; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1969-03-15

    742 cases of thyroid diseases treated at Radio-isotope Clinic, Seoul National University Hospital since October 1965 through July 1968 were analyzed. The patients were classified according to eye findings, as to Infiltrative, Non-infiltrative and No ophthalmopathy. Correlations between ophthalmo-logical findings and symptoms, BMR values and {sup 131}I uptake rate as well as response to medical treatment were carefully reviewed. Results obtained were as follows: 1) Among goitrous patients 44.5% with infiltrative ophthalmopathy, 24.1% with non-infiltrative ophthalmopathy totaling 68.6% of patients with one or more eye findings were found. Exophthalmos (44%) and visual disturbances (44%) comprised the highest incidence among eye signs. Most frequent eye symptoms were lid swelling (17.1%). 2) Female patients were predominant (91%). 3) Of cases with hyperthyroidism, after treatment with antithyroid drugs and radio-iodine therapy, general symptoms were improved in over 74%, whereas ophthalmopathy was not changed and in some cases the eye signs were aggravated. This tendency was more apparent in infiltrative ophthalmopathy. 4) Significant correlations between exophthalmos, BMR values and {sup 131}I uptake rate were found. Among the patients of same degree of exophthalmos, BMR values and {sup 131}I uptake rate showed the highest in non-infiltrative ophthalmos, BMR values and {sup 131}I uptake rate showed the highest in non-infiltrative ophthalmopathy, moderate in infiltrative ophthalmopathy and the lowest in no ophthalmopathy.

  1. Clinical Study on the Eye Changes in the Goiter Patients

    International Nuclear Information System (INIS)

    Ku, In Soo; Lee, Jung Sang; Lee, Kyung Ja; Choi, Kuen Chul; Ahn, Soo Byuk; Lee, Chang Kyu; Lee, Mun Ho

    1969-01-01

    742 cases of thyroid diseases treated at Radio-isotope Clinic, Seoul National University Hospital since October 1965 through July 1968 were analyzed. The patients were classified according to eye findings, as to Infiltrative, Non-infiltrative and No ophthalmopathy. Correlations between ophthalmo-logical findings and symptoms, BMR values and 131 I uptake rate as well as response to medical treatment were carefully reviewed. Results obtained were as follows: 1) Among goitrous patients 44.5% with infiltrative ophthalmopathy, 24.1% with non-infiltrative ophthalmopathy totaling 68.6% of patients with one or more eye findings were found. Exophthalmos (44%) and visual disturbances (44%) comprised the highest incidence among eye signs. Most frequent eye symptoms were lid swelling (17.1%). 2) Female patients were predominant (91%). 3) Of cases with hyperthyroidism, after treatment with antithyroid drugs and radio-iodine therapy, general symptoms were improved in over 74%, whereas ophthalmopathy was not changed and in some cases the eye signs were aggravated. This tendency was more apparent in infiltrative ophthalmopathy. 4) Significant correlations between exophthalmos, BMR values and 131 I uptake rate were found. Among the patients of same degree of exophthalmos, BMR values and 131 I uptake rate showed the highest in non-infiltrative ophthalmos, BMR values and 131 I uptake rate showed the highest in non-infiltrative ophthalmopathy, moderate in infiltrative ophthalmopathy and the lowest in no ophthalmopathy.

  2. Quality indicators for eye bank.

    Science.gov (United States)

    Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta

    2018-03-01

    The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  3. Small Drusen and Age-Related Macular Degeneration: The Beaver Dam Eye Study

    Directory of Open Access Journals (Sweden)

    Ronald Klein

    2015-03-01

    Full Text Available We tested the hypothesis that large areas of small hard drusen (diameter <63 µm and intermediate drusen (diameter 63–124 µm are associated with the incidence of age-related macular degeneration (AMD. Eyes of 3344 older adults with at least two consecutive visits spaced five years apart over a 20-year period were included. A 6-level severity scale, including no drusen, four levels of increasing area (from minimal (<2596 µm² to large (>9086 µm² of only small hard drusen, and intermediate drusen, was used. The five-year incidence of AMD was 3% in eyes at the start of the interval with no, minimal, small, and moderate areas of only small drusen and 5% and 25% for eyes with large area of only small drusen and intermediate drusen, respectively. Compared to eyes with a moderate area of small drusen, the odds ratio (OR of developing AMD in eyes with a large area of only small drusen was 1.8 (p < 0.001. Compared to eyes with large area of only small drusen, eyes with intermediate drusen had an OR of 5.5 (p < 0.001 of developing AMD. Our results are consistent with our hypothesis that large areas of only small drusen are associated with the incidence of AMD.

  4. Implicit prosody mining based on the human eye image capture technology

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  5. Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye study.

    Science.gov (United States)

    Cerviño, Alejandro; Bansal, Dheeraj; Hosking, Sarah L; Montés-Micó, Robert

    2008-07-01

    To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessions: 2 without realigning between measurements, 1 with realignment, and 1 with an angular shift of 6 degrees from the instrument axis. Three measurements were made in the human eyes with the C-Quant straylight meter (Oculus) to obtain psychometric and objective measures of retinal straylight. Analysis of variance, intraclass correlation coefficients, coefficient of repeatability (CoR), and correlations were used to determine intrasession and intersession repeatability and the relationship between measures. No significant differences were found between the sessions in the model eye (P=.234). The mean CoR was less than 10% in all model- and human-eye sessions. After incomplete patterns were removed, good correlation was achieved between psychometric and objective scatter measurements despite the small sample size (n=6; r=-0.831; P=.040). The methodology was repeatable in model and human eyes, strong against realignment and misalignment, and sensitive. Clinical application would benefit from effective use of the sensor's dynamic range.

  6. Analysis of Ocular Firework-Related Injuries and Common Eye Traumata: a 5-year Clinical Study.

    Science.gov (United States)

    Frimmel, S; Theusinger, O M; Kniestedt, C

    2017-04-01

    Background A comparative study of eye injuries related to fireworks or acts of violence around New Year's Eve and the Swiss National Day on August 1st. The two groups were compared with respect to the overall numbers of eye accidents within the period of review. Patients and Methods Retrospective analysis of emergency consultations at the Department of Ophthalmology, University Hospital Zurich with eye accidents around the Swiss National Day on August 1st and New Year's Eve over the last 5 years. Two subgroups were formed: (1) Firework-related eye traumata, (2) Eye injuries due to acts of violence. The groups were analysed by age, gender, active participant or bystander, eye involved, severity of trauma (from clinical findings), surgical interventions, time of follow-up and visits, visual acuity and outcome. Results The study included 97 patients (100 eyes) with 74 male (76 %) and 23 female (24 %) victims. After filtering out 67 common traumata cases (all unilateral), 17 patients (18 eyes) with firework-related injuries and 13 patients (15 eyes) with damage due to an act of violence remained. Firework injuries accounted for 18 % of cases (65 % men); eye injuries caused by an act of violence accounted for 15 % of cases (92 % men). In the fireworks group, women were significantly older than men (mean age men 32 ± 14 years versus women 38 ± 16 years, p = 0.002). 65 % of cases were bystanders. The two subgroups contained 30 patients (33 eyes) with 22 left eyes (67 %, p fireworks group (28 %), than in the violence group (13 %). 87 % of the victims in the group of common traumata were mild trauma, 10 % moderate and 3 % severe. In the fireworks group the distribution was 53 % mild, 12 % moderate and 35 % severe, in the violence group 46 %, 23 % and 31 % respectively. Severe trauma cases occurred significantly more often around the New Year, with 36 % versus August 1st with 18 % (p = 0.0028). They are more often

  7. Postural And Eye-Positional Effects On Human Biting Force: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Altay Tabancacı

    2012-06-01

    Full Text Available Muscle groups affected on biting force are called temporal muscle as a major and masseter muscle as a minor. According to the human posture stability, forces of these muscles vary with the force directions. In this case, experimental investigation is strictly important such that biting force under different postural and eye- positional situations is changed. In this study, seven-male and seven-female within the age-range of 17-24 are considered corresponding to having with restorated molar tooth and without that type of tooth. With the help of specially designed biting fork, different posture- and eye-positions are investigated for experimental biting force analysis. Changes in eye-positions are not indicated significant difference for all postural positions. On one hand, it is obtained that biting force of no-filling tooth in men becomes maximum if facial muscles give full effort to biting. On the other hand, effect of facial muscles for women is not clearly noticed depending on the postural differences.

  8. The Added Value of Eye-tracking in Diagnosing Dyscalculia: A Case Study

    Directory of Open Access Journals (Sweden)

    Sietske eVan Viersen

    2013-10-01

    Full Text Available The present study compared eye movements and performance of a nine-year-old girl with Developmental Dyscalculia (DD on a series of number line tasks to those of a group of typically developing (TD children (n = 10, in order to answer the question whether eye-tracking data from number line estimation tasks can be a useful tool to discriminate between TD children and children with a number processing deficit. Quantitative results indicated that the child with dyscalculia performed worse on all symbolic number line tasks compared to the control group, indicated by a low linear fit (R2 and a low accuracy measured by mean percent absolute error. In contrast to the control group, her magnitude representations seemed to be better represented by a logarithmic than a linear fit. Furthermore, qualitative analyses on the data of the child with dyscalculia revealed more unidentifiable fixation patterns in the processing of multi-digit numbers and more dysfunctional estimation strategy use in one third of the estimation trials as opposed to approximately 10% in the control group. In line with her dyscalculia diagnosis, these results confirm the difficulties with spatially representing and manipulating numerosities on a number line, resulting in inflexible and inadequate estimation or processing strategies. It can be concluded from this case study that eye-tracking data can be used to discern different number processing and estimation strategies in TD children and children with a number processing deficit. Hence, eye-tracking data in combination with number line estimation tasks might be a valuable and promising addition to current diagnostic measures.

  9. The added value of eye-tracking in diagnosing dyscalculia: a case study.

    Science.gov (United States)

    van Viersen, Sietske; Slot, Esther M; Kroesbergen, Evelyn H; Van't Noordende, Jaccoline E; Leseman, Paul P M

    2013-01-01

    The present study compared eye movements and performance of a 9-year-old girl with Developmental Dyscalculia (DD) on a series of number line tasks to those of a group of typically developing (TD) children (n = 10), in order to answer the question whether eye-tracking data from number line estimation tasks can be a useful tool to discriminate between TD children and children with a number processing deficit. Quantitative results indicated that the child with dyscalculia performed worse on all symbolic number line tasks compared to the control group, indicated by a low linear fit (R (2)) and a low accuracy measured by mean percent absolute error. In contrast to the control group, her magnitude representations seemed to be better represented by a logarithmic than a linear fit. Furthermore, qualitative analyses on the data of the child with dyscalculia revealed more unidentifiable fixation patterns in the processing of multi-digit numbers and more dysfunctional estimation strategy use in one third of the estimation trials as opposed to ~10% in the control group. In line with her dyscalculia diagnosis, these results confirm the difficulties with spatially representing and manipulating numerosities on a number line, resulting in inflexible and inadequate estimation or processing strategies. It can be concluded from this case study that eye-tracking data can be used to discern different number processing and estimation strategies in TD children and children with a number processing deficit. Hence, eye-tracking data in combination with number line estimation tasks might be a valuable and promising addition to current diagnostic measures.

  10. Airbag deployment-related eye injuries.

    Science.gov (United States)

    Koisaari, Tapio; Leivo, Tiina; Sahraravand, Ahmad; Haavisto, Anna-Kaisa; Sulander, Pekka; Tervo, Timo M T

    2017-07-04

    We studied the correlation between airbag deployment and eye injuries using 2 different data sets. The registry of the Finnish Road Accident (FRA) Investigation Teams was analyzed to study severe head- and eyewear-related injuries. All fatal passenger car or van accidents that occurred during the years 2009-2012 (4 years) were included (n = 734). Cases in which the driver's front airbag was deployed were subjected to analysis (n = 409). To determine the proportion of minor, potentially airbag-related eye injuries, the results were compared to the data for all new eye injury patients (n = 1,151) recorded at the Emergency Clinic of the Helsinki University Eye Hospital (HUEH) during one year, from May 1, 2011, to April 30, 2012. In the FRA data set, the unbelted drivers showed a significantly higher risk of death (odds ratio [OR] = 5.89, 95% confidence interval [CI], 3.33-10.9, P = 2.6E-12) or of sustaining head injuries (OR = 2.50, 95% CI, 1.59-3.97, P = 3.8E-5). Only 4 of the 1,151 HUEH patients were involved in a passenger car accident. In one of the crashes, the airbag operated, and the belted driver received 2 sutured eye lid wounds and showed conjunctival sugillation. No permanent eye injuries were recorded during the follow-up. The calculated annual airbag-related eye injury incidence was less than 1/1,000,000 people, 4/100,000 accidents, and 4/10,000 injured occupants. Airbag-related eye injuries occurred very rarely in car accidents in cases where the occupant survived and the restraint system was appropriately used. Spectacle use did not appear to increase the risk of eye injury in restrained occupants.

  11. Topical administration of regorafenib eye drops: phase I dose-escalation study in healthy volunteers.

    Science.gov (United States)

    Zimmermann, Torsten; Höchel, Joachim; Becka, Michael; Boettger, Michael K; Rohde, Beate; Schug, Barbara; Kunert, Kathleen S; Donath, Frank

    2018-05-01

    Regorafenib is a multikinase inhibitor under investigation for use in neovascular age-related macular degeneration. In this phase I study, regorafenib eye drops were administered to healthy volunteers to provide information on safety, tolerability and systemic exposure. This was a single-centre, randomized, double-masked, parallel-group, dose-escalation, placebo-controlled study. Subjects received regorafenib eye drops (30 mg ml -1 , 25 μl) as a 0.75 mg single dose (Cohort 1), 0.75 mg twice daily (bid) or thrice daily (tid) over 14 days (Cohorts 2 and 3, respectively), 1.5 mg tid unilaterally for 3 days, then bilaterally for up to 14 days (Cohort 4), or placebo. Plasma samples were taken to estimate systemic exposure. Safety and functional assessments were performed throughout the study. Thirty-six subjects received regorafenib and 12 received placebo. Regorafenib was safe and well tolerated over the dose range. No pathological changes occurred in the anterior, vitreous or posterior eye compartments. Mild eyelid redness, oedema and conjunctival hyperaemia were observed across all regorafenib cohorts; these were comparable with the effects seen with placebo. Predominant symptoms were blurred vision in the active and placebo groups. Systemic safety evaluations showed no clinically relevant findings. Absolute systemic exposure after multiple administrations of regorafenib eye drops at a dose of 0.75 mg was 600-700-fold lower than after multiple oral administration of 160 mg day -1 , the dose approved in cancer indications. These results indicate a favourable safety and tolerability profile of regorafenib eye drops up to 30 mg ml -1 tid for use in clinical studies. © 2018 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.

  12. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  13. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  14. I spy, I spy with my little eye

    NARCIS (Netherlands)

    Ribbers, J.; Keuten, M.G.A.; van Rompay, T.

    2017-01-01

    Aims
    The basis of this study lies in hygiene of swimming pools, where it is argued that taking a pre-swim shower would lead to a decrease in release of pollutants in the swimming pool, which in the end would lead to the decrease of health issues as red eyes and asthma. However, previous research

  15. Body-centred map in parietal eye fields - functional MRI study

    International Nuclear Information System (INIS)

    Brotchie, P.; Chen, D.Y.; Bradley, W.G.

    2002-01-01

    Full text: In order for us to interact with our environment we need to know where objects are around us, relative to our body. In monkeys, a body-centred map of visual space is known to exist within the parietal eye fields. This map is formed by the modulation of neuronal activity by eye and head position (Brotchie et al, Nature 1995; Synder et al, Nature 1998). In humans no map of body centred space has been demonstrated. By using functional MRI we have localised a region along the intraparietal sulcus which has properties similar to the parietal eye fields of monkeys (Brotchie et al, ISMRM, 2000). The aim of this study was to determine if activity in this region is modulated by head position, consistent with a body centered representation of visual space. Functional MRI was performed on 6 subjects performing simple visually guided saccades using a 1.5 Tesla GE Echospeed scanner. 10 scans were performed on the 6 subjects at left and right body orientations. Regions of interest were selected around the intraparietal sulcus proper (IPSP) of both hemispheres and voxels with BOLD signal which correlated with the paradigm (r>0.35) were selected for further analysis. Comparisons of percentage signal change were made between the left and right IPSP using Student t test. Of the 10 MRI examinations, 6 demonstrated statistically significant differences in the amount of signal change between left and right IPSP. In each of these 6 cases, the signal change was greater within the IPSP contralateral to the direction of head position relative to the body. This indicates a modulation of activity within the IPSP related to head position, most likely reflecting modulation of the underlying neuronal activity and suggests the existence of a body-centred encoding of space within the parietal eye fields of humans. Copyright (2002) Blackwell Science Pty Ltd

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  17. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  18. Indigenous practices among Palestinians for healing eye diseases and inflammations.

    Science.gov (United States)

    Abu-Rabia, Aref

    2005-01-01

    This paper briefly describes the state health services in general, and eye care in particular for Palestinian Arabs under the British Mandate (1917-1948). The paper will also discuss the environmental and cultural origins of the prevalence of eye diseases among Palestinian Arabs. The second part of the research describes in detail indigenous practices of traditional medicine for healing trachoma and other eye diseases, inflammation that were prevalent in Mandatory Palestine.

  19. Protecting the ocular surface and improving the quality of life of dry eye patients: a study of the efficacy of an HP-guar containing ocular lubricant in a population of dry eye patients.

    Science.gov (United States)

    Rolando, Maurizio; Autori, Silvia; Badino, Francesco; Barabino, Stefano

    2009-06-01

    The aim of this study was to evaluate the efficacy of a non-Newtonian tear substitute containing 0.4% polyethylene glycol 400 (PEG 400) and 0.3% propylene glycol in an 0.18% hydroxypropyl-guar (HPG) containing vehicle (Systane Lubricant Eye Drops; Alcon) in reducing the signs and symptoms of dry eye, as well as its effect on ocular protection. Twenty patients with moderate to severe dry eye were enrolled in a 28-day prospective, randomized, controlled study. Subjects self-administered the HPG containing ocular lubricant four times daily (QID) over the study duration. After 28 days, the effect of the HPG containing ocular lubricant was evaluated by means of the Global Staining Score (a measure of the corneal and conjunctival staining), inter-blink tear film stability, Ocular Protection Index (OPI), and subjective symptoms. The HPG containing ocular lubricant produced statistically significant improvements compared with baseline in dry eye symptoms (P eye symptoms with the HPG containing ocular lubricant -- evident as early as the first follow-up visit (Day 7) and continued throughout the 28 days of the study with a concurrent, increase in OPI to a level greater than unity -- indicate that this preparation is a fast-acting, long-lasting, and effective treatment for dry eye. In concurrence with the results from previously published clinical studies, the HPG containing ocular lubricant has shown efficacy in alleviating the signs and symptoms of dry eye as well as affording improved ocular surface protection.

  20. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Yu Ling

    2018-01-01

    Full Text Available AIM: To investigate the effect of recombinant bovine basic fibroblast growth factor(rb-bFGFeye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: Totally 80 patients with 80 affected eyes undergoing age-related cataract surgery in our hospital from January 2015 to October 2016 were selected as study subjects, and they were randomly divided into control group and experimental group with 40 patients(40 affected eyesin each group. The two groups were treated with hydroxyl indican eye drops and rb-bFGF eye drops, respectively. The clinical curative effect, inflammation related factors \\〖interleukin 6(IL-6, tumor necrosis factor α(TNF-α\\〗, Schirmer test(SⅠt, break-up time(BUTof tear film, corneal sodium fluorescein staining(FLand scores of dry eye symptoms in the two groups were observed. RESULTS: The total treatment effective rate of experimental group after treatment was significantly higher than that of the control group(90.0% vs 72.5%; χ2=4.021, PP>0.05. After treatment, IL-6, TNF-α, SⅠt, FL score and scores of dry eye symptoms in two groups significantly decreased while BUT significantly increased(PPCONCLUSION: In the treatment of patients after age-related cataract after surgery, rb-bFGF eye drops has more advantages over hydroxyl indican eye drops in regulating the expression of inflammatory factors, improving the tear film stability and relieving dry eye symptoms.

  1. Functional magnetic resonance imaging of the frontal eye fields during saccadic eye movements

    International Nuclear Information System (INIS)

    Miki, Atsushi; Takagi, Mineo; Abe, Haruki; Nakajima, Takashi; Miyauchi, Satoru.

    1996-01-01

    We evaluated activity-induced signal intensity changes in the human cerebral cortex during horizontal saccadic eye movements using functional magnetic resonance imaging (fMRI) based on the blood-oxygenation-level-dependent (BOLD) contrast method. Compared with central fixation, significant signal increases were observed bilaterally in the middle frontal gyrus (Brodmann area 8) during saccadic conditions. The location of the activated area was consistent with that of previously reported frontal eye fields (FEF). These results suggest that fMRI has potential merit for the study of cortical control of eye movements in humans. (author)

  2. The role of interword spacing in reading Japanese: an eye movement study.

    Science.gov (United States)

    Sainio, Miia; Hyönä, Jukka; Bingushi, Kazuo; Bertram, Raymond

    2007-09-01

    The present study investigated the role of interword spacing in a naturally unspaced language, Japanese. Eye movements were registered of native Japanese readers reading pure Hiragana (syllabic) and mixed Kanji-Hiragana (ideographic and syllabic) text in spaced and unspaced conditions. Interword spacing facilitated both word identification and eye guidance when reading syllabic script, but not when the script contained ideographic characters. We conclude that in reading Hiragana interword spacing serves as an effective segmentation cue. In contrast, spacing information in mixed Kanji-Hiragana text is redundant, since the visually salient Kanji characters serve as effective segmentation cues by themselves.

  3. Development of Text Reading in Japanese: An Eye Movement Study

    Science.gov (United States)

    Jincho, Nobuyuki; Feng, Gary; Mazuka, Reiko

    2014-01-01

    This study examined age-group differences in eye movements among third-grade, fifth-grade, and adult Japanese readers. In Experiment 1, Japanese children, but not adults, showed a longer fixation time on logographic kanji words than on phonologically transparent hiragana words. Further, an age-group difference was found in the first fixation…

  4. Dosimetry studies with 32P source and correlation of skin and eye lens doses

    International Nuclear Information System (INIS)

    Kumar, Munish; Gaonkar, U.P.; Koul, D.K.; Datta, D.; Saxena, S.K.; Kumar, Yogendra; Dash, A.

    2018-01-01

    Beta particles are one of the major contributors toward skin and eye lens doses at facilities handling beta sources. These sources find applications in industry, pharmaceuticals as well as in brachytherapy applications. The beta particles having maximum (E max ) energy > 0.07 MeV are capable of delivering skin dose whereas beta particles having maximum (E max ) energy > 0.7 MeV may also contribute towards dose to eye lens. Studies are performed using 32 P beta source as its maximum beta energy (E max ) is such that for sources having (E max ) of 1.71 MeV or beyond, there can be substantial contribution towards dose to eye lens even the dose limit recommended for skin is followed

  5. Eye gazing direction inspection based on image processing technique

    Science.gov (United States)

    Hao, Qun; Song, Yong

    2005-02-01

    According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.

  6. Histological study on the effect of He-Ne laser on the compound eyes of the locust Schistocerca Gregaria Forsk (Orthoptera-Acridiidae)

    International Nuclear Information System (INIS)

    Abd El-Meguid, A.; El-Gundi, A.M.; Osiris, W.G.; El-Kes, N.

    1996-01-01

    In the present study, the effect of the He-Ne laser beam at different exposure periods (10,30 and 60 minutes) on the histological structure of the compound eyes of Schistocerca Gregaria Forsk is investigated. This study shows that various remarkable changes occurred in the histological structure of the right exposed eye (R) as in the left eye (L) (unexposed eye of the same insect), which may be due to a change in the micro-environment of the compound eyes, affected by the laser beam, furthermore, damage in the photoreceptors of the compound eyes of the insect was observed. 23 figs

  7. When Art Moves the Eyes: A Behavioral and Eye-Tracking Study

    Science.gov (United States)

    Massaro, Davide; Savazzi, Federica; Di Dio, Cinzia; Freedberg, David; Gallese, Vittorio; Gilli, Gabriella; Marchetti, Antonella

    2012-01-01

    The aim of this study was to investigate, using eye-tracking technique, the influence of bottom-up and top-down processes on visual behavior while subjects, naïve to art criticism, were presented with representational paintings. Forty-two subjects viewed color and black and white paintings (Color) categorized as dynamic or static (Dynamism) (bottom-up processes). Half of the images represented natural environments and half human subjects (Content); all stimuli were displayed under aesthetic and movement judgment conditions (Task) (top-down processes). Results on gazing behavior showed that content-related top-down processes prevailed over low-level visually-driven bottom-up processes when a human subject is represented in the painting. On the contrary, bottom-up processes, mediated by low-level visual features, particularly affected gazing behavior when looking at nature-content images. We discuss our results proposing a reconsideration of the definition of content-related top-down processes in accordance with the concept of embodied simulation in art perception. PMID:22624007

  8. NEUROMARKETING IN MARKET RESEARCH

    Directory of Open Access Journals (Sweden)

    Dijana Ćosić

    2016-03-01

    Full Text Available Neuromarketing is a fairly new discipline that combines behavioural psychology, economics and consumer neuroscience. With the help of different techniques, such as functional magnetic resonance, electroencephalography, positron emission tomography, eye tracker etc., it measures respondent’s reaction to different stimuli. It allows the researchers to gain insight into unconscious drivers of choice and preference which they would not be able to discover with traditional methods (focus groups, in depth interviews and questionnaires. In market research, most widely used neuromarketing technique is eye tracker. Me and my associates conducted a typical market research study of a TV commercial with a help of a stationary eye tracker and “Gazepoint” software. 21 respondents participated in the study. The study discovered that one scene in the commercial drew attention much more than the others. As neuromarketing raises ethical issues I reviewed the literature related to these issues and presented an overview of neuromarketing and neuromarketing techniques as well.

  9. [Macroeconomic costs of eye diseases].

    Science.gov (United States)

    Hirneiß, C; Kampik, A; Neubauer, A S

    2014-05-01

    Eye diseases that are relevant regarding their macroeconomic costs and their impact on society include cataract, diabetic retinopathy, age-related maculopathy, glaucoma and refractive errors. The aim of this article is to provide a comprehensive overview of direct and indirect costs for major eye disease categories for Germany, based on existing literature and data sources. A semi-structured literature search was performed in the databases Medline and Embase and in the search machine Google for relevant original papers and reviews on costs of eye diseases with relevance for or transferability to Germany (last research date October 2013). In addition, manual searching was performed in important national databases and information sources, such as the Federal Office of Statistics and scientific societies. The direct costs for these diseases add up to approximately 2.6 billion Euros yearly for the Federal Republic of Germany, including out of the pocket payments from patients but excluding optical aids (e.g. glasses). In addition to those direct costs there are also indirect costs which are caused e.g. by loss of employment or productivity or by a reduction in health-related quality of life. These indirect costs can only be roughly estimated. Including the indirect costs for the eye diseases investigated, a total yearly macroeconomic cost ranging between 4 and 12 billion Euros is estimated for Germany. The costs for the eye diseases cataract, diabetic retinopathy, age-related maculopathy, glaucoma and refractive errors have a macroeconomic relevant dimension. Based on the predicted demographic changes with an ageing society an increase of the prevalence and thus also an increase of costs for eye diseases is expected in the future.

  10. Omega-3 fatty acid supplementation improves dry eye symptoms in patients with glaucoma: results of a prospective multicenter study

    Directory of Open Access Journals (Sweden)

    Tellez-Vazquez J

    2016-04-01

    Full Text Available Jesús Tellez-Vazquez On behalf of the Dry Eye In Glaucoma Study Group (DEIGSG Glaucoma Section, Ophthalmology Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain Purpose: The purpose of this study is to assess the effectiveness and tolerability of a dietary supplement with a combination of omega-3 fatty acids and antioxidants on dry eye symptoms caused by chronic instillation of antihypertensive eye drops in patients with glaucoma. Patients and methods: A total of 1,255 patients with glaucoma and dry eye symptoms related to antiglaucoma topical medication participated in an open-label, uncontrolled, prospective, and multicenter study and were instructed to take three capsules a day of the nutraceutical formulation (Brudypio® 1.5 g for 12 weeks. Dry eye symptoms (graded as 0–3 [none to severe, respectively], conjunctival hyperemia, tear breakup time, Schirmer I test, Oxford grading scheme, and intraocular pressure were assessed. Results: After 12 weeks of administration of the dietary supplement, all dry eye symptoms improved significantly (P<0.001 (mean 1.3 vs 0.6 for scratching, 1.4 vs 0.7 for stinging sensation, 1.6 vs 0.7 for grittiness, 1.0 vs 0.4 for tired eyes, 1.1 vs 0.5 for grating sensation, and 0.8 vs 0.3 for blurry vision. The Schirmer test scores and the tear breakup time also increased significantly. There was an increase in the percentage of patients grading 0–I in the Oxford scale and a decrease in those grading IV–V. Compliance was recorded in 62.5% of patients. In compliant patients, the mean differences at 12 weeks vs baseline of dry eye symptoms were statistically significant as compared to noncompliant patients. Conclusion: Dietary supplementation with Brudypio® may be a clinically valuable additional option for the treatment of dry eye syndrome in patients with glaucoma using antiglaucoma eye drops. These results require confirmation with an appropriately designed randomized controlled study

  11. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  12. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  13. Rapid eye movement sleep behavior disorder

    DEFF Research Database (Denmark)

    Schenck, C H; Montplaisir, J Y; Frauscher, B

    2013-01-01

    We aimed to provide a consensus statement by the International Rapid Eye Movement Sleep Behavior Disorder Study Group (IRBD-SG) on devising controlled active treatment studies in rapid eye movement sleep behavior disorder (RBD) and devising studies of neuroprotection against Parkinson disease (PD...

  14. Impact of First Eye versus Second Eye Cataract Surgery on Visual Function and Quality of Life.

    Science.gov (United States)

    Shekhawat, Nakul S; Stock, Michael V; Baze, Elizabeth F; Daly, Mary K; Vollman, David E; Lawrence, Mary G; Chomsky, Amy S

    2017-10-01

    To compare the impact of first eye versus second eye cataract surgery on visual function and quality of life. Cohort study. A total of 328 patients undergoing separate first eye and second eye phacoemulsification cataract surgeries at 5 veterans affairs centers in the United States. Patients with previous ocular surgery, postoperative endophthalmitis, postoperative retinal detachment, reoperation within 30 days, dementia, anxiety disorder, hearing difficulty, or history of drug abuse were excluded. Patients received complete preoperative and postoperative ophthalmic examinations for first eye and second eye cataract surgeries. Best-corrected visual acuity (BCVA) was measured 30 to 90 days preoperatively and postoperatively. Patients completed the National Eye Institute Visual Functioning Questionnaire (NEI-VFQ) 30 to 90 days preoperatively and postoperatively. The NEI-VFQ scores were calculated using a traditional subscale scoring algorithm and a Rasch-refined approach producing visual function and socioemotional subscale scores. Postoperative NEI-VFQ scores and improvement in NEI-VFQ scores comparing first eye versus second eye cataract surgery. Mean age was 70.4 years (±9.6 standard deviation [SD]). Compared with second eyes, first eyes had worse mean preoperative BCVA (0.55 vs. 0.36 logarithm of the minimum angle of resolution (logMAR), P < 0.001), greater mean BCVA improvement after surgery (-0.50 vs. -0.32 logMAR, P < 0.001), and slightly worse postoperative BCVA (0.06 vs. 0.03 logMAR, P = 0.039). Compared with first eye surgery, second eye surgery resulted in higher postoperative NEI-VFQ scores for nearly all traditional subscales (P < 0.001), visual function subscale (-3.85 vs. -2.91 logits, P < 0.001), and socioemotional subscale (-2.63 vs. -2.10 logits, P < 0.001). First eye surgery improved visual function scores more than second eye surgery (-2.99 vs. -2.67 logits, P = 0.021), but both first and second eye surgeries resulted in similar

  15. From the eyes and the heart: a novel eye-gaze metric that predicts video preferences of a large audience

    OpenAIRE

    Christoforou, Christoforos; Christou-Champi, Spyros; Constantinidou, Fofi; Theodorou, Maria

    2015-01-01

    Eye-tracking has been extensively used to quantify audience preferences in the context of marketing and advertising research, primarily in methodologies involving static images or stimuli (i.e., advertising, shelf testing, and website usability). However, these methodologies do not generalize to narrative-based video stimuli where a specific storyline is meant to be communicated to the audience. In this paper, a novel metric based on eye-gaze dispersion (both within and across viewings) that ...

  16. Quality indicators for eye bank

    Directory of Open Access Journals (Sweden)

    Manisha Acharya

    2018-01-01

    Full Text Available Purpose: The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Methods: Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions – “result quality” and “process quality.” The indicators were measured and tracked as part of quality assurance (QA program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011–2016. Results: Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%, discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. Conclusion: These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  17. Effects of diquafosol sodium eye drops on tear film stability in short BUT type of dry eye.

    Science.gov (United States)

    Shimazaki-Den, Seika; Iseda, Hiroyuki; Dogru, Murat; Shimazaki, Jun

    2013-08-01

    To investigate the effects of diquafosol sodium (DQS) eye drops, a purinergic P2Y2 receptor agonist, on tear film stability in patients with unstable tear film (UTF). Two prospective studies were conducted. One was an exploratory nonrandomized trial on 39 eyes with dry eye symptoms and short tear film break-up time (BUT), but without epithelial damage. Changes in symptoms, BUT, Schirmer value, and ocular surface fluorescein staining (FS) scores were studied for 3 months. The other was a randomized clinical trial of DQS and artificial tears (AT) in 17 eyes with short BUT. Eyes with decreased Schirmer values (≤ 5 mm) were excluded. Changes in symptoms, BUT, FS scores, and tear film stability using continuous corneal topographic analysis were studied for 4 weeks. In the exploratory study, while Schirmer values were not significantly increased, significant improvements in symptoms and BUT were noted at both 1 and 3 months. In the randomized clinical trial, significant improvements in symptoms were noted in the DQS group, but not in the AT group, at 2 weeks. BUT was significantly prolonged in the DQS group at 4 weeks but not in the AT group. No significant changes were noted in FS scores or tear film stability. DQS improved subjective symptoms and prolonged BUT in eyes with UTF not associated with low tear secretion and ocular surface epithelial damage. Because many patients who have UTF are refractory to conventional treatments, DQS may offer benefits in the treatment of dry eyes.

  18. Influence on ocular surface after cataract surgery and effect of topical diquafosol on postoperative dry eye: a multicenter prospective randomized study

    Directory of Open Access Journals (Sweden)

    Miyake K

    2017-03-01

    Full Text Available Kensaku Miyake,1 Norihiko Yokoi2 On behalf of Dry Eye After Cataract Surgery Investigational Study Group (DASIS group 1Miyake Eye Hospital, Nagoya, 2Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan Purpose: To investigate influences of 3% diquafosol sodium ophthalmic solution (DQS on ocular surface after cataract surgery and effects on postoperative dry eye. Design: This study had two consecutive prospective study phases. The former was an observational study from before cataract surgery to 4 weeks after surgery and the latter was a randomized open-label study from 4 to 8 weeks after surgery. Methods: Subjects were 433 eyes of 433 patients undergoing cataract surgery with intraocular lens implantation. Dry eye examination of tear breakup time (BUT, corneal and conjunctival fluorescein staining scores, total subjective symptom score (12 symptoms, and Schirmer I test were conducted before surgery and 4 weeks after surgery. Patient demographics and these examination results were used to analyze risk factors to predict postoperative dry eye. In a randomized study, 154 eyes diagnosed with dry eye postoperatively were applied either DQS or artificial tears (AT six times daily for 4 weeks. The data of the examinations were compared. Results: At 4 weeks after surgery, BUT was shortened significantly (P=0.036, fluorescein staining score increased significantly (P=0.012, but total subjective symptom score was significantly improved (P<0.001. The majority of postoperative dry eye was shortened BUT type (53.1%. The dry eye prevalence after surgery decreased (55.7% compared with before surgery (69.7%. Females and the patient with dry eye symptoms before surgery had significant risk factors for postoperative dry eye. In a randomized study, BUT was significantly prolonged in the DQS group (P=0.015, but not in the AT group. Fluorescein staining score was significantly improved in both groups (P<0.001. Total subjective symptom

  19. Snapshots of the EYES project

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Evers, L.; Wu Jian, W.J.; Karl, H.; Kopke, A.; Handziski, V.; Zorzi, M.

    2004-01-01

    The EYES project (IST-2001-34734) is a three years European research project on self-organizing and collaborative energy-efficient sensor networks. It addresses the convergence of distributed information processing, wireless communications, and mobile computing. The goal of the project is to develop

  20. EYES -- Energy Efficient Sensor Networks

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Etalle, Sandro; Karl, Holger; Petrioli, Chiara; Zorzi, Michele; Kip, Harry; Lentsch, Thomas; Conti, M.; Giordano, S.; Gregori, E.; Olariu, S.

    The EYES project (IST-2001-34734) is a three years European research project on self-organizing and collaborative energy-efficient sensor networks. It will address the convergence of distributed information processing, wireless communications, and mobile computing. The goal of the project is to

  1. BirdsEyeView (BEV: graphical overviews of experimental data

    Directory of Open Access Journals (Sweden)

    Zhang Lifeng

    2012-09-01

    Full Text Available Abstract Background Analyzing global experimental data can be tedious and time-consuming. Thus, helping biologists see results as quickly and easily as possible can facilitate biological research, and is the purpose of the software we describe. Results We present BirdsEyeView, a software system for visualizing experimental transcriptomic data using different views that users can switch among and compare. BirdsEyeView graphically maps data to three views: Cellular Map (currently a plant cell, Pathway Tree with dynamic mapping, and Gene Ontology http://www.geneontology.org Biological Processes and Molecular Functions. By displaying color-coded values for transcript levels across different views, BirdsEyeView can assist users in developing hypotheses about their experiment results. Conclusions BirdsEyeView is a software system available as a Java Webstart package for visualizing transcriptomic data in the context of different biological views to assist biologists in investigating experimental results. BirdsEyeView can be obtained from http://metnetdb.org/MetNet_BirdsEyeView.htm.

  2. Exploring the Predisposition of the Asian Eye to Development of Dry Eye.

    Science.gov (United States)

    Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min

    2016-07-01

    To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all Pdry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all Pdry eye. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A HOSPITAL-BASED STUDY ON THE PREVALENCE OF DRY EYES IN A TERTIARY CARE HOSPITAL

    OpenAIRE

    Prashant V. Solanke; Preeti Pawde; A. Vinolin Maria Sebastina

    2017-01-01

    BACKGROUND Dry eye syndrome is a common eye disease. Dry Eye Syndrome (DES), also known as Keratoconjunctivitis Sicca (KCS), is the condition of having dry eyes. Other associated symptoms include irritation, redness, discharge and easily fatigued eyes. Blurred vision may also occur. The symptoms can range from mild and occasional to severe and continuous. Scarring of the cornea may occur in some cases without treatment. Dry eye occurs when either the eye does not produce enough...

  4. Comparative study of eye dose and chest dose received during radiopharmaceutical production processes

    International Nuclear Information System (INIS)

    Chindarkar, A.S.; Chavan, S.V.; Sawant, D.K.; Sahoo, L.; Gopalakrishnan, R.K.; Sneha, C.; Sachdev, S.S.; Dey, A.C.

    2018-01-01

    Radiopharmaceutical laboratory, BRIT, Vashi produces different radiopharmaceuticals of 131 I, 153 Sm, 99 Mo/ 99m Tc and 177 Lu. Principle gamma energies of these isotopes vary from 103 to 740 KeV and their maximum beta energies vary from 384 to 1214 KeV. In the light of the revised eye lens dose limit recommended in IAEA Basic Safety Standard Interim Edition No. GSR Part 3 (IAEA-2011), the study of radiation dose for eye lens was carried out using CaSO 4 : Dy based Thermo luminescence dosimeter (TLD). This TLD was worn at center of the forehead to measure eye lens dose. This TLD dose was then compared with chest TLD dose to deduce any correlation between these TLD doses. These TLD doses were assessed on quarterly basis. Eight quarter data of these TLD doses were compared

  5. An Eye-Tracking Study of How Color Coding Affects Multimedia Learning

    Science.gov (United States)

    Ozcelik, Erol; Karakus, Turkan; Kursun, Engin; Cagiltay, Kursat

    2009-01-01

    Color coding has been proposed to promote more effective learning. However, insufficient evidence currently exists to show how color coding leads to better learning. The goal of this study was to investigate the underlying cause of the color coding effect by utilizing eye movement data. Fifty-two participants studied either a color-coded or…

  6. Studies of cytotoxic antibodies against eye muscle antigens in patients with thyroid-associated ophthalmopathy

    International Nuclear Information System (INIS)

    Zhang, Z.-G.; Hiromatsu, Y.; Salvi, M.; Triller, H.; Bernard, N.; Wall, J.R.; Medeiros-Neto, G.; Iacona, A.; Lima, N.

    1989-01-01

    We have studied the prevalence and significance of cytotoxic antibodies against human eye muscle cells, as detected in antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-mediated antibody-dependent cytotoxicity (CMAC) in 51 Cr release assays, in patients with Graves' ophthalmopathy or Hashimoto's thyroiditis. A high prevalence of positive ADCC tests was found in all groups of patients with ophthalmopathy tested. Tests were positive in 64% of patients with Graves' ophthalmopathy from an area of severe iodine deficiency (Sao Paulo) and in 64% of such patients from an iodine replete area (Montreal). In patients with so-called ''euthyroid ophthalmopathy'', i.e. eye disease associated with thyroiditis, ADCC tests were positive in 75 and 38% of patients from the two areas, respectively, while tests were positive in 40 and 22%, respectively, of patients with Graves' hyperthyroidism without evident eye disease. In normal subjects, levels of 51 Cr release was always at background levels. In a group of patients from the high-iodine area, levels of antibodies in ADCC correlated positively with the intraocular pressure (mmHg) in primary position as a parameter of eye muscle dysfunction. In patients with ophthalmopathy, positive ADCC tests were assciated with antibodies to eye muscle membrane antigens of 55,65 and 95 kD as detected by immunoblotting, although the correlation was not close for any antigen. in contrast, CMAC tests were negative in all patients with ophthalmopathy. We also tested 9 mouse and 10 human monoclonal antibodies, reactive with orbital antigens in an enzyme-linked immunosorbent assay, for cytotoxic activity, in ADCC and CMAC, against eye muscle and thyroid cells. All monoclonal antibodies were of the IgM class and negative in ADCC assays. When tested in CMAC against eye muscle cells, one of 9 mouse and 5 of 8 human monoclonal antibodies showed significant activity while tests were positive in one of 9 and one of 10 monoclonal antibodies

  7. Eye dosimetry and protective eye wear for interventional clinicians

    International Nuclear Information System (INIS)

    Martin, C.J.; Magee, J.S.; Sandblom; Almen, A.; Lundh, C.

    2015-01-01

    Doses to the eyes of interventional clinicians can exceed 20 mSv. Various protective devices can afford protection to the eyes with the final barrier being protective eye wear. The protection provided by lead glasses is difficult to quantify, and the majority of dosimeters are not designed to be worn under lead glasses. This study has measured dose reduction factors (DRFs) equal to the ratio of the dose with no protection, divided by that when lead glasses are worn. Glasses have been tested in X-ray fields using anthropomorphic phantoms to simulate the patient and clinician. DRFs for X-rays incident from the front vary from 5.2 to 7.6, while values for orientations reminiscent of clinical practice are between 1.4 and 5.2. Results suggest that a DRF of two is a conservative factor that could be applied to personal dosimeter measurements to account for the dose reduction provided by most types of lead glasses. (authors)

  8. Pseudoexfoliation Glaucoma in the National Eye Center, Cicendo Eye Hospital, January–October 2012

    Directory of Open Access Journals (Sweden)

    Rizki Fasa Ramdhani

    2015-03-01

    Full Text Available Background: Pseudoexfoliation syndrome is characterized by the deposition of a distinctive fibrillar material in the anterior segment of the eye. This condition is a major risk factor for development of glaucoma, termed pseudoexfoliation glaucoma (PEXG. The aim of this study was to describe the characteristic and management of PEXG in the National Eye Center Cicendo Eye Hospital. Methods: A descriptive retrospective study was conducted in October–November 2012 using medical records of PEXG patients in the National Eye Center Cicendo Eye Hospital during January–October 2012. Results: There were 32 patients (43 eyes diagnosed as PEXG, most of them were male (78.1%, age 70–74 years old (34.4% and followed by those in the range of age 65–69 years old (21.9%. Most of the cases were unilateral (65.6% decrease of visual acuity less than 3/60 (76.7%, increase of intraocular pressure (IOP with majority in the range of 31–40 mmHg (32.6% and 41–50 mmHg (32.6%, Cup/Disc Ratio 0.9–1.0 (46.51% and followed by those classified as majority which were hard to assess because of the presence of opaque media (34.89%. The type of glaucoma was open angle glaucoma (88.4%. The treatment received was a combination of two types of antiglaucoma medication and surgery IOP Conclusion: PEXG is mostly found in elderly patients. While most of the patients come with high IOP and late stage of the disease IOP

  9. The role of eye protection in work-related eye injuries.

    Science.gov (United States)

    Fong, L P; Taouk, Y

    1995-05-01

    A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.

  10. Timing of Pars Plana Vitrectomy in Management of Gunshot Perforating Eye Injury: Observational Study

    Directory of Open Access Journals (Sweden)

    Hammouda Hamdy Ghoraba

    2016-01-01

    Full Text Available The aim of this study is to report the difference in either anatomical or functional outcome of vitreoretinal intervention in cases of gunshot perforating eye injury if done 2–4 weeks or after the 4th week after the original trauma. Patients were treated with pars plana vitrectomy and silicon oil. Surgeries were performed in the period from February 2011 until the end of December 2014. 253 eyes of 237 patients were reviewed. 46 eyes were excluded. 207 eyes of 197 patients were analyzed. The included eyes were classified based on the timing of vitrectomy in relation to the initial trauma into two groups: 149 eyes (the first group operated on between the 3rd and the 4th week and 58 eyes (the second group operated on after the 4th week after the trauma. Following one surgical intervention, in the first group, attached retina was achieved in 93.28% of patients. In the second group, attached retina was achieved in 96.55% of patients. All RD cases could be attached by a second surgery. Visual acuity improved in 81.21% of patients, did not change in 15.43% of patients, and declined in 3.35% of patients. In the second group, visual acuity improved in 81.03% of patients, did not change in 12.06% of patients, and worsened in 6.89% of patients. There was no statistically significant difference between the two groups in either anatomical or functional results. We recommend interfering before the 5th week after the trauma as retinal detachment is encountered more in cases operated on after the 4th week. The visual outcome depends on the site of entry and exit (the route of gunshot.

  11. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life.

    Science.gov (United States)

    Rasmussen, Marie Louise Roed

    2010-12-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity and frequency among EA patients. We attempted to identify patients with increased risk of developing pain after EA and investigated if preoperative pain is a risk factor for a later development of phantom pain (paper III); In addition we wanted to investigate the health related quality of life, perceived stress, self rated health, job separation due to illness or disability and socio-economic position of the EA in comparison with the general Danish population (paper IV). Records on 431 EA patients, clinical ophthalmological examination and an interview study of 173 EA patients and a questionnaire answered by 120 EA patients. The most frequent indications for EA in Denmark were painful blind eye (37%) and neoplasm (34%). During the study period 1996-2003, the annual number of eye amputations was stable, but an increase in bulbar eviscerations was noticed. Orbital implants were used with an increasing tendency until 2003. The Phantom eye syndrome is frequent among EA patients. Visual hallucinations were described by 42% of the patients. The content were mainly elementary visual hallucinations, with white or colored light as a

  12. [Study on A White-Eye Pattern in Dielectric Barrier Discharge by Optical Emission Spectrum].

    Science.gov (United States)

    Zhu, Ping; Dong, Li-fang; Yang, Jing; Zhang, Yu; Zhang, Chao

    2015-06-01

    The white-eye pattern was firstly observed and investigated in a dielectric barrier discharge system in the mixture of argon and air whose content can be varied whenever necessary, and the study shows that the white-eye cell is an interleaving of three different hexagonal sub-structures: the center spot, the halo, and the ambient spots. The white-eye pattern is observed at a lower applied voltage. In this experiment, the heat capacity of water is high so that the water in water electrode is good at absorbing heat. In the process of pattern discharging the gas gap didn't increase its temperature, and the discharging phenomenon of this pattern has not changed. The temperature of the water electrodes almost keeps unchanged during the whole experiment, which is advantageous for the long-term stable measurement. Pictures recorded by ordinary camera with long exposure time in the same argon content condition show that the center spot, the halo, and the ambient spots og the white-eye pattern have different brightness, which may prove that their plasma states are different. And, it is worth noting that there are obvious differences of brightness not only on the center spot, the halo, and the ambient spots at the same pressure but also at the different pressure, which shows that its plasma state also changed with the variation of the pressure. Given this, in this experiment plasma temperatures of the central spot, halo, and ambient spots in a white-eye pattern at different gas pressure were studied by using optical emission spectra. The molecular vibration temperature is investigated by the emission spectra of nitrogen band of second positive system ( C3Πu --> B3Πg ). The electron excitation temperature is researched by the relative intensity ratio method of spectral lines of Ar I 763. 51 nm (2P6 --> 1S5) and Ar I 772. 42 nm (2P2 --> 1S3). The electronic density is investigated by the broadening of spectral line 696.5 nm. Through the analysis of experimental results, it

  13. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  14. Effect of school eye health promotion on children's eye health literacy in Vietnam.

    Science.gov (United States)

    Paudel, Prakash; Yen, Phung Thi; Kovai, Vilas; Naduvilath, Thomas; Ho, Suit May; Giap, Nguyen Viet; Holden, Brien A

    2017-10-06

    Health promotion intervention in schools is a useful strategy to improve students' health awareness. The purpose of this study was to assess the effect of eye health promotion interventions on eye health literacy in school children in Vietnam. A piloted questionnaire was administered to 300 children from five secondary schools in Ba Ria-Vung Tau, Vietnam at baseline and re-administered after the eye health promotion interventions. McNemar chi-square and logistic regression were used for statistical analysis. A total of 300 children aged 12-15 years (mean, 13.3 ± 1.3 years; 60% female) participated in the baseline survey. The participation rate in the post-health promotion survey was 94.7%. After the health promotion interventions, number of children who had correct eye health knowledge increased by 10-20% (60-75% to 70-95%), more children reported having had an eye examination (63.3% to 84.7%; p promotion interventions significantly improve eye health knowledge, attitudes and practices of school children. Additionally, participation of parents and teachers as change agents may further improve children's health literacy. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Evaluation of treatment for dry eye with 2-hydroxyestradiol using a dry eye rat model.

    Science.gov (United States)

    Higuchi, Akihiro; Oonishi, Erina; Kawakita, Tetsuya; Tsubota, Kazuo

    2016-01-01

    2-hydroxy estradiol (2-OHE2) is a catechol derivative of 17β -Estradiol (E2) and it is synthesized from E2 catalyzed by cytochrome P4501A1. Previous studies reported that 2-OHE2 is a physiologic antioxidant in lipoproteins, liver microsomes, and the brain. Catechol derivatives show an anti-inflammatory effect through the inhibition of prostaglandin endoperoxide synthase (PGS) activity. Corneal erosion caused by dry eye is related to an increase in oxidative stress and inflammation in ocular surface cells. We investigated the therapeutic effects of 2-OHE2 on corneal damage caused by dry eye. Steroidal radical scavenging activity was confirmed through the electron spin resonance (ESR) method. PGS activity was measured using the COX Fluorescent Activity Assay Kit. To evaluate the effect of 2-OHE2 on the treatment for dry eye, 2-OHE2 was applied as an eye drop experiment using dry eye model rats. 2-OHE2 scavenged tyrosyl radical and possibly suppressed oxidative stress in corneal epithelial cells. In addition, 2-OHE2 inhibited PGS activity, and 2-OHE2 is probably a competitive inhibitor of PGS. Corneal PGS activity was upregulated in the dry eye group. Therefore, 2-OHE2 eye drops improved corneal erosion in dry eye model rats. 2-OHE2 is a candidate for the treatment of dry eye through the suppression of inflammation and oxidative stress in the cornea.

  16. Ultraviolet damage to the eye revisited: eye-sun protection factor (E-SPF®), a new ultraviolet protection label for eyewear

    Science.gov (United States)

    Behar-Cohen, Francine; Baillet, Gilles; de Ayguavives, Tito; Garcia, Paula Ortega; Krutmann, Jean; Peña-García, Pablo; Reme, Charlotte; Wolffsohn, James S

    2014-01-01

    Ultraviolet (UV) radiation potentially damages the skin, the immune system, and structures of the eye. A useful UV sun protection for the skin has been established. Since a remarkable body of evidence shows an association between UV radiation and damage to structures of the eye, eye protection is important, but a reliable and practical tool to assess and compare the UV-protective properties of lenses has been lacking. Among the general lay public, misconceptions on eye-sun protection have been identified. For example, sun protection is mainly ascribed to sunglasses, but less so to clear lenses. Skin malignancies in the periorbital region are frequent, but usual topical skin protection does not include the lids. Recent research utilized exact dosimetry and demonstrated relevant differences in UV burden to the eye and skin at a given ambient irradiation. Chronic UV effects on the cornea and lens are cumulative, so effective UV protection of the eyes is important for all age groups and should be used systematically. Protection of children’s eyes is especially important, because UV transmittance is higher at a very young age, allowing higher levels of UV radiation to reach the crystalline lens and even the retina. Sunglasses as well as clear lenses (plano and prescription) effectively reduce transmittance of UV radiation. However, an important share of the UV burden to the eye is explained by back reflection of radiation from lenses to the eye. UV radiation incident from an angle of 135°–150° behind a lens wearer is reflected from the back side of lenses. The usual antireflective coatings considerably increase reflection of UV radiation. To provide reliable labeling of the protective potential of lenses, an eye-sun protection factor (E-SPF®) has been developed. It integrates UV transmission as well as UV reflectance of lenses. The E-SPF® compares well with established skin-sun protection factors and provides clear messages to eye health care providers and to

  17. Looking at vision : Eye/face/head tracking of consumers for improved marketing decisions

    NARCIS (Netherlands)

    Wedel, M.; Pieters, R.; Moutinho, L.; Bigné, E.; Manrai (eds.), A.K.

    Against the backdrop of the rapid growth of the use eye tracking and facial recognition methodology, this chapter discusses the measurement of eye movements, facial expression of emotions, pupil dilation, eye blinks and head movements. After discussing some of the main research findings in the

  18. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  20. Is eye damage caused by stereoscopic displays?

    Science.gov (United States)

    Mayer, Udo; Neumann, Markus D.; Kubbat, Wolfgang; Landau, Kurt

    2000-05-01

    A normal developing child will achieve emmetropia in youth and maintain it. Thereby cornea, lens and axial length of the eye grow astonishingly coordinated. In the last years research has evidenced that this coordinated growing process is a visually controlled closed loop. The mechanism has been studied particularly in animals. It was found that the growth of the axial length of the eyeball is controlled by image focus information from the retina. It was shown that maladjustment can occur by this visually-guided growth control mechanism that result in ametropia. Thereby it has been proven that e.g. short-sightedness is not only caused by heredity, but is acquired under certain visual conditions. It is shown that these conditions are similar to the conditions of viewing stereoscopic displays where the normal accommodation convergence coupling is disjoint. An evaluation is given of the potential of damaging the eyes by viewing stereoscopic displays. Concerning this, different viewing methods for stereoscopic displays are evaluated. Moreover, clues are given how the environment and display conditions shall be set and what users shall be chosen to minimize the risk of eye damages.

  1. Processing of Written Irony in Autism Spectrum Disorder: An Eye-Movement Study.

    Science.gov (United States)

    Au-Yeung, Sheena K; Kaakinen, Johanna K; Liversedge, Simon P; Benson, Valerie

    2015-12-01

    Previous research has suggested that individuals with Autism Spectrum Disorders (ASD) have difficulties understanding others communicative intent and with using contextual information to correctly interpret irony. We recorded the eye movements of typically developing (TD) adults ASD adults when they read statements that could either be interpreted as ironic or non-ironic depending on the context of the passage. Participants with ASD performed as well as TD controls in their comprehension accuracy for speaker's statements in both ironic and non-ironic conditions. Eye movement data showed that for both participant groups, total reading times were longer for the critical region containing the speaker's statement and a subsequent sentence restating the context in the ironic condition compared to the non-ironic condition. The results suggest that more effortful processing is required in both ASD and TD participants for ironic compared with literal non-ironic statements, and that individuals with ASD were able to use contextual information to infer a non-literal interpretation of ironic text. Individuals with ASD, however, spent more time overall than TD controls rereading the passages, to a similar degree across both ironic and non-ironic conditions, suggesting that they either take longer to construct a coherent discourse representation of the text, or that they take longer to make the decision that their representation of the text is reasonable based on their knowledge of the world. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.

  2. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  3. Intense pulsed light treatment for dry eye disease due to meibomian gland dysfunction; a 3-year retrospective study.

    Science.gov (United States)

    Toyos, Rolando; McGill, William; Briscoe, Dustin

    2015-01-01

    The purpose of this study was to determine the clinical benefits of intense-pulsed-light therapy for the treatment of dry-eye disease caused by meibomian gland dysfunction (MGD). MGD is the leading cause of evaporative dry eye disease. It is currently treated with a range of methods that have been shown to be only somewhat effective, leading to the need for advanced treatment options. A retrospective noncomparative interventional case series was conducted with 91 patients presenting with severe dry eye syndrome. Treatment included intense-pulsed-light therapy and gland expression at a single outpatient clinic over a 30-month study. Pre/post tear breakup time data were available for a subset of 78 patients. For all patients, a specially developed technique for the treatment of dry eye syndrome was applied as a series of monthly treatments until there was adequate improvement in dry eye syndrome symptoms by physician judgment, or until patient discontinuation. Primary outcomes included change in tear breakup time, self-reported patient satisfaction, and adverse events. Physician-judged improvement in dry eye tear breakup time was found for 68 of 78 patients (87%) with seven treatment visits and four maintenance visits on average (medians), and 93% of patients reported post-treatment satisfaction with degree of dry eye syndrome symptoms. Adverse events, most typically redness or swelling, were found for 13% of patients. No serious adverse events were found. Although preliminary, study results of intense-pulsed-light therapy treatment for dry eye syndrome caused by meibomian gland dysfunction are promising. A multisite clinical trial with a larger sample, treatment comparison groups, and randomized controlled trials is currently underway.

  4. Influence on ocular surface after cataract surgery and effect of topical diquafosol on postoperative dry eye: a multicenter prospective randomized study

    Science.gov (United States)

    Miyake, Kensaku; Yokoi, Norihiko

    2017-01-01

    Purpose To investigate influences of 3% diquafosol sodium ophthalmic solution (DQS) on ocular surface after cataract surgery and effects on postoperative dry eye. Design This study had two consecutive prospective study phases. The former was an observational study from before cataract surgery to 4 weeks after surgery and the latter was a randomized open-label study from 4 to 8 weeks after surgery. Methods Subjects were 433 eyes of 433 patients undergoing cataract surgery with intraocular lens implantation. Dry eye examination of tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, total subjective symptom score (12 symptoms), and Schirmer I test were conducted before surgery and 4 weeks after surgery. Patient demographics and these examination results were used to analyze risk factors to predict postoperative dry eye. In a randomized study, 154 eyes diagnosed with dry eye postoperatively were applied either DQS or artificial tears (AT) six times daily for 4 weeks. The data of the examinations were compared. Results At 4 weeks after surgery, BUT was shortened significantly (P=0.036), fluorescein staining score increased significantly (P=0.012), but total subjective symptom score was significantly improved (Pdry eye was shortened BUT type (53.1%). The dry eye prevalence after surgery decreased (55.7%) compared with before surgery (69.7%). Females and the patient with dry eye symptoms before surgery had significant risk factors for postoperative dry eye. In a randomized study, BUT was significantly prolonged in the DQS group (P=0.015), but not in the AT group. Fluorescein staining score was significantly improved in both groups (P<0.001). Total subjective symptom score was significantly decreased in the AT group (P<0.001), but not in the DQS group. Conclusion Our study suggests that cataract surgery has harmful effects on tear film stability and ocular surface, and DQS has a capability to improve them. PMID:28360509

  5. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2015-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  6. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2014-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  7. A prospective, contralateral eye study comparing thin-flap LASIK (sub-Bowman keratomileusis) with photorefractive keratectomy.

    Science.gov (United States)

    Slade, Stephen G; Durrie, Daniel S; Binder, Perry S

    2009-06-01

    To determine the differences in the visual results, pain response, biomechanical effect, quality of vision, and higher-order aberrations, among other parameters, in eyes undergoing either photorefractive keratectomy (PRK) or thin-flap LASIK/sub-Bowman keratomileusis (SBK; intended flap thickness of +/-100 microm and 8.5-mm diameter) at 1, 3, and 6 months after surgery. A contralateral eye pilot study. Fifty patients (100 eyes) were enrolled at 2 sites. The mean preoperative spherical refraction was -3.66 diopters (D) and the mean cylinder was -0.66 D for all eyes. Eyes in the PRK group underwent 8.5-mm ethanol-assisted PRK, whereas in eyes in the SBK group, an 8.5-mm, (intended) 100-microm flap was created with a 60-kHz IntraLase femtosecond laser (Advanced Medical Optics, Santa Ana, CA). All eyes underwent a customized laser ablation using an Alcon LADARVision 4000 CustomCornea excimer laser (Alcon Laboratories, Fort Worth, TX). Preoperative and postoperative tests included best spectacle-corrected visual acuity, uncorrected visual acuity (UCVA), corneal topography, wavefront aberrometry, retinal image quality, and contrast sensitivity. Patients completed subjective questionnaires at each visit. One- and 3-month UCVA results showed a statistically significant difference: SBK, 88% 20/20 or better vs. 48% 20/20 or better for PRK. At 6 months, UCVA was 94% 20/20 or better for PRK and 92% for SBK. At 1 and 3 months, the SBK group had lower higher-order aberrations (coma and spherical aberration; PPRK group. By 3 months, the vision in the 2 groups had begun to equalize, although the SBK eyes continued to have better vision. At 6 months, there were no statistical differences between the 2 groups. Proprietary or commercial disclosure may be found after the references.

  8. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  9. Eye Tracker Accuracy: Quantitative Evaluation of the Invisible Eye Center Location

    OpenAIRE

    Wyder, Stephan; Cattin, Philippe C.

    2017-01-01

    Purpose. We present a new method to evaluate the accuracy of an eye tracker based eye localization system. Measuring the accuracy of an eye tracker's primary intention, the estimated point of gaze, is usually done with volunteers and a set of fixation points used as ground truth. However, verifying the accuracy of the location estimate of a volunteer's eye center in 3D space is not easily possible. This is because the eye center is an intangible point hidden by the iris. Methods. We evaluate ...

  10. Are higher blood mercury levels associated with dry eye symptoms in adult Koreans? A population-based cross-sectional study

    Science.gov (United States)

    Chung, So-Hyang

    2016-01-01

    Objectives The purpose of this study was to investigate whether blood mercury concentrations associated with the presence of dry eye symptoms in a nationally representative Korean population. Methods Population-based prospective cross-sectional study using the heavy metal data set of the 2010–2012 Korean National Health and Nutrition Examination Survey (KNHANES). A total of 4761 adult Koreans were the eligible population in this study. Of the 7162 survey participants, 2401 were excluded because they were mercury levels were measured on the day the participants completed a questionnaire regarding the presence of dry eye symptoms (persistent dryness or eye irritation). The population was divided into low and high groups by median level (4.26 and 2.89 µg/L for males and females, respectively). Results Self-reported dry eye symptoms were present in 13.0% of the cohort. Participants with dry eye symptoms were significantly more likely to have blood mercury levels exceeding the median than those without dry eye symptoms (45.7% vs 51.7%, p=0.021). Logistic regression analysis showed that, after adjusting for age, gender, education, total household income, smoking status, heavy alcohol use, sleep time, perceived stress status, total cholesterol levels and atopy history, dry eye symptoms were significantly associated with blood mercury levels that exceeded the median (reference: lower mercury group; OR, 1.324; 95% CI 1.059 to 1.655; pmercury levels were associated with dry eye symptoms in a nationally representative Korean population. PMID:27121705

  11. Prevalence and Associations of Incomplete Posterior Vitreous Detachment in Adult Chinese: The Beijing Eye Study

    Science.gov (United States)

    Shao, Lei; Xu, Liang; You, Qi Sheng; Wang, Ya Xing; Chen, Chang Xi; Yang, Hua; Zhou, Jin Qiong; Jonas, Jost B.; Wei, Wen Bin

    2013-01-01

    Purpose To determine prevalence and associations of incomplete posterior vitreous detachment (PVD). Methods The population-based cross-sectional Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range: 50–93 years). A detailed ophthalmic examination was performed including spectral-domain optical coherence tomography (SD-OCT). Incomplete PVD was differentiated into type 1 (shallow PVD with circular perifoveal vitreous attachment), type 2 (PVD reaching fovea but not foveola), type 3 (shallow PVD with pinpoint vitreous attachment at the foveola), and type 4 (PVD completely detached from the macula, attached to the optic disc). Results An incomplete PVD was detected in 3948 eyes (prevalence: 60.5±0.6%; 95% Confidence Interval (CI): 59.3%,61.7%) of 2198 subjects (67.1±0.8%;95%CI: 65.6%,68.7%). Type 1 PVD was seen in 3090 (78.3%) eyes, type 2 PVD in 504 (12.8%) eyes, type 3 PVD in 70 (1.8%) eyes, and type 4 PVD in 284 (7.2%) eyes. Prevalence of incomplete PVD was associated with younger age (PPVD was associated with higher age (PPVD (detected in 67.1% subjects) was associated with younger age, male gender, rural region of habitation, larger corneal diameter, better best corrected visual acuity and hyperopic refractive error. PMID:23544043

  12. Narrative comprehension and production in children with SLI: An eye movement study

    Science.gov (United States)

    ANDREU, LLORENÇ; SANZ-TORRENT, MONICA; OLMOS, JOAN GUÀRDIA; MACWHINNEY, BRIAN

    2014-01-01

    This study investigates narrative comprehension and production in children with specific language impairment (SLI). Twelve children with SLI (mean age 5; 8 years) and 12 typically developing children (mean age 5; 6 years) participated in an eye-tracking experiment designed to investigate online narrative comprehension and production in Catalan- and Spanish-speaking children with SLI. The comprehension task involved the recording of eye movements during the visual exploration of successive scenes in a story, while listening to the associated narrative. With regard to production, the children were asked to retell the story, while once again looking at the scenes, as their eye movements were monitored. During narrative production, children with SLI look at the most semantically relevant areas of the scenes fewer times than their age-matched controls, but no differences were found in narrative comprehension. Moreover, the analyses of speech productions revealed that children with SLI retained less information and made more semantic and syntactic errors during retelling. Implications for theories that characterize SLI are discussed. PMID:21453036

  13. Clinical effect of 1g/L anthocyanin eye-patch for mild and moderate dry eye

    Directory of Open Access Journals (Sweden)

    Ke-Hua Wang

    2018-05-01

    Full Text Available AIM:To evaluate the clinic efficacy of 1g/L anthocyanin eye-patch for mild and moderate dry eye. METHODS: In this prospective and multicenter study, a total of 320 cases(640 eyeswith mild and moderate dry eye were enrolled from 8 Aier Eye Hospitals in Changsha, Chongqing, Wuhan and so on from October 2016 to April 2017. The patients were assigned to eye patch group(160 casesand artificial tears group(160 casesbased on random number table. The patients in eye-patch group used 1g/L of anthocyanin eye-patch for more than 6h during night sleep, while the patients in artificial tears group used polyvinyl alcohol eye drops for 4 times per day. The evaluation of symptoms and signs were conducted on 1d before the treatment and 14d after the treatment. The evaluation of symptoms adopted the Ocular Surface Disease Index(OSDI, while the observation of signs included tear secretion test(Schirmer Ⅰ test, SⅠt, first noninvasive tear breakup time(NITBUTfas well as average noninvasive tear breakup time(NITBUTavmeasured by Oculus ocular surface analyser. RESULTS: OSDI score, NITBUTf and NITBUTav in the two groups after treatment were significantly improved compared with that before treatment, and the difference had a statistical significance(PP>0.05. There was no significant difference in OSDI score, NITBUTf, NITBUTav and SⅠt between the two groups after treatment(P>0.05.CONCLUSION: The 1g/L anthocyanin eye-patch has similar efficacy with artificial tears for mild and moderate dry eye, which can effectively improve the symptoms and tear film stability.

  14. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    Science.gov (United States)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  15. Integrated model of primary and secondary eye care for underserved rural areas: The L V Prasad Eye Institute experience

    Directory of Open Access Journals (Sweden)

    Gullapalli N Rao

    2012-01-01

    Full Text Available Blindness is a major global public health problem and recent estimates from World Health Organization (WHO showed that in India there were 62 million visually impaired, of whom 8 million are blind. The Andhra Pradesh Eye Disease Study (APEDS provided a comprehensive estimate for prevalence and causes of blindness for the state of Andhra Pradesh (AP. It also highlighted that uptake of services was also an issue, predominantly among lower socio-economic groups, women, and rural populations. On the basis of this analysis, L V Prasad Eye Institute (LVPEI developed a pyramidal model of eye care delivery. This article describes the LVPEI eye care delivery model. The article discusses infrastructure development, human resource development, and service delivery (including prevention and promotion in the context of primary and secondary care service delivery in rural areas. The article also alludes to opportunities for research at these levels of service delivery and the amenability of the evidence generated at these levels of the LVPEI eye health pyramid for advocacy and policy planning. In addition, management issues related to the sustainability of service delivery in rural areas are discussed. The article highlights the key factors required for the success of the LVPEI rural service delivery model and discusses challenges that need to be overcome to replicate the model. The article concludes by noting the potential to convert these challenges into opportunities by integrating certain aspects of the existing healthcare system into the model. Examples include screening of diabetes and diabetic retinopathy in order to promote higher community participation. The results of such integration can serve as evidence for advocacy and policy.

  16. The genetics of eye colours in an Italian population measured with an objective method for eye colour quantification

    DEFF Research Database (Denmark)

    Pietroni, C.; Andersen, J.D.; Johansen, P.

    2013-01-01

    Brown and blue eye colours are primarily explained by the single nucleotide polymorphism (SNP) HERC2 rs12913832. However, the genetics of eye colours that appear to be neither blue nor brown are not well understood. In this study, 230 unrelated Italian individuals were typed for 32 SNP loci...... in the iris region and calculated a Pixel Index of the Eye (PIE-score) that described the eye colours quantitatively. The PIE-score ranged from _1 to 1 (brown to blue). We investigated the association of the PIE-scores extracted from the eye images with the genotypes of the 32 pigmentary SNPs. We observed...

  17. Burning Eye Syndrome: Do Neuropathic Pain Mechanisms Underlie Chronic Dry Eye?

    Science.gov (United States)

    Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Felix, Elizabeth R; Alegret, Ramon; Sarantopoulos, Constantine D

    2016-04-01

    Dry eye is a multi-factorial disorder that manifests with painful ocular symptoms and visual disturbances, which can only be partly attributed to tear dysfunction. This disorder may also involve neuroplasticity in response to neuronal injury. This review will emphasize the key characteristics of dry eye pain and its pathologic mechanisms, making the argument that a subset of dry eye represents a neuropathic pain disorder of the eye, more appropriately called "burning eye syndrome." A literature review was conducted using a PubMed search focusing on dry eye, corneal nociception, and neuropathic pain. Articles were reviewed and those discussing clinical course, pathophysiology, and neuronal regulation of chronic ocular pain as related to dry eye were summarized. We found that there is a discordance between ocular pain and dryness on the ocular surface. Although tear dysfunction may be one of the initial insults, its persistence may be associated with repeated ocular sensory nerve injury leading to an acute-to-chronic pain transition associated with neuropathologic changes (peripheral and central sensitization), neuronal dysfunction, and spontaneous ocular pain. Dry eye is becoming a major health concern due to its increasing incidence, significant morbidity, and economic burden. Recent evidence suggests that a subset of dry eye may be better represented as a chronic neuropathic pain disorder due to its features of dysesthesia, spontaneous pain, allodynia, and hyperalgesia. Future therapies targeted at the underlying neuroplasticity may yield improved efficacy for patients with this subset of dry eye, which we term "burning eye syndrome." © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Evaluation of a community-based participatory farmworker eye health intervention in the "black dirt" region of New York state.

    Science.gov (United States)

    Earle-Richardson, Giulia; Wyckoff, Lynae; Carrasquillo, Marilyn; Scribani, Melissa; Jenkins, Paul; May, John

    2014-09-01

    Eye irritation is a constant hazard for migrant and seasonal farmworkers, but there are few studies of the problem or how to address it. Researchers evaluated the effect of a community-based participatory eye health intervention on farmworker eye symptoms in the Hudson Valley, NY. A randomized pre-post intervention with 2, 4-week follow-up periods was implemented with a sample of 97 farmworkers. Five eye symptoms were measured, along with utilization of protective eyewear and eye drops. Leading baseline eye symptoms were redness (49%), blurred vision (43%), itching (43%), and eye pain (29%). Significant reductions in eye pain (P = 0.009), and non-significant reductions in redness were observed for the intervention group while controls experienced increases in both. The intervention was effective in significantly reducing eye pain, and to a lesser extent, redness. Future eyewear promotion programs should offer a range of eye wear, tailor offerings to local climate and tasks, evaluate eyewear durability, and include eye drops. © 2014 Wiley Periodicals, Inc.

  19. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  20. Are higher blood mercury levels associated with dry eye symptoms in adult Koreans? A population-based cross-sectional study.

    Science.gov (United States)

    Chung, So-Hyang; Myong, Jun-Pyo

    2016-04-27

    The purpose of this study was to investigate whether blood mercury concentrations associated with the presence of dry eye symptoms in a nationally representative Korean population. Population-based prospective cross-sectional study using the heavy metal data set of the 2010-2012 Korean National Health and Nutrition Examination Survey (KNHANES). A total of 4761 adult Koreans were the eligible population in this study. Of the 7162 survey participants, 2401 were excluded because they were eye surgery. Blood mercury levels were measured on the day the participants completed a questionnaire regarding the presence of dry eye symptoms (persistent dryness or eye irritation). The population was divided into low and high groups by median level (4.26 and 2.89 µg/L for males and females, respectively). Self-reported dry eye symptoms were present in 13.0% of the cohort. Participants with dry eye symptoms were significantly more likely to have blood mercury levels exceeding the median than those without dry eye symptoms (45.7% vs 51.7%, p=0.021). Logistic regression analysis showed that, after adjusting for age, gender, education, total household income, smoking status, heavy alcohol use, sleep time, perceived stress status, total cholesterol levels and atopy history, dry eye symptoms were significantly associated with blood mercury levels that exceeded the median (reference: lower mercury group; OR, 1.324; 95% CI 1.059 to 1.655; pdry eye symptoms in a nationally representative Korean population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Ultraviolet radiation and the eye: an epidemiologic study.

    Science.gov (United States)

    Taylor, H R

    1989-01-01

    Circumstantial evidence from biochemical, animal, and epidemiologic studies suggests an association between exposure to UV-B radiation (290 nm to 320 nm) and cataract. Such an association had not been proven because it had not been possible to quantify ocular UV-B exposure of individuals or to reliably grade the type and severity of cataract in field studies. We undertook an epidemiologic survey of cataract among 838 watermen who work on the Chesapeake Bay. Their individual ocular UV-B exposure was quantified for each year of life over the age of 16, on the basis of a detailed occupational history combined with laboratory and field measurements of ocular UV-B exposure. Cataracts were graded by both type and severity through clinical and photographic means. SMD changes were ascertained by fundal photography. A general medical history was taken to discover potentially confounding factors. This study showed that people with cortical lens opacities had a 21% higher UV-B exposure at each year of life than people without these opacities. A doubling in lifetime UV-B exposure led to a 60% increase in the risk of cortical cataract, and those with a high annual UV-B exposure increased their risk of cortical cataract over threefold. Corneal changes, namely pterygium and CDK, were also strongly associated with high UV-B exposure. No association was found between nuclear lens opacities or macular degeneration and UV-B exposure. This study also indicated several simple, practical measures, such as wearing spectacles or a hat, that effectively protect the eye from UV-B exposure. Thus it is easily within the power of individuals to protect their eyes from excessive UV-B exposure and reduce their risk of cortical cataract. A program of public education in this area could be a cost-effective means of reducing this important disease. PMID:2562534

  2. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  3. Prevalence and clinical characteristics of dry eye disease in community-based type 2 diabetic patients: the Beixinjing eye study.

    Science.gov (United States)

    Zou, Xinrong; Lu, Lina; Xu, Yi; Zhu, Jianfeng; He, Jiangnan; Zhang, Bo; Zou, Haidong

    2018-05-10

    This study was performed to evaluate the prevalence and clinical characteristics of dry eye disease (DED) in community-based type 2 diabetic patients and to identify the associated factors related with DED. A total of 1360 type 2 diabetic patients in the Beixinjing community were randomly selected. All participants were given a questionnaire that assessed basic information and subjective symptoms.DED was diagnosed using the revised Japanese DED diagnostic criteria. All subjects underwent a routine ophthalmic examination, corneal sensitivity test, tear film break-up time(BUT) test, Schirmer I test, fluorescein and lissamine green staining(FL) and fundus photography. Diabetic retinopathy (DR) was graded according to the International severity scale of diabetic retinopathy and diabetic macular edema. Of the 1360 subjects, 238 (17.5%) were diagnosed with DED. There was a significant association between the presence of DED and higher blood glucose (P dry eye examination should be added to the routine screening of diabetes.

  4. A portable device for measuring donor corneal transparency in eye banks.

    Science.gov (United States)

    Parekh, Mohit; Ferrari, Stefano; Ruzza, Alessandro; Pugliese, Mariarosaria; Ponzin, Diego; Salvalaio, Gianni

    2014-03-01

    To develop a portable device for measuring the donor corneal transparency and validate its efficacy for corneal evaluation in the eye-banks and for research. The transparency device (TD) has a light source, a detachable system for corneal insertion and a base for light transmission. The probe detects the transmitted light which is measured by a lux-meter. A contact lens was set as 'control' to reduce the light scattering concern, an empty petri-plate as 'blank' and the cornea as 'sample'. Two experts and non-experts (masked) observed the corneas for subjective analysis which was then compared using the TD. The parameters observed were scars, foreign-body, stromal-deformities, folds, thickness and opacity which were then converted to a relative overall percentage by the observer. Twenty corneas were evaluated for correlation, five tissues to obtain standard-deviation and twenty-four pairs for a comparative study. Experts mimicked the eye-banks with long-term experience while non-experts mimicked the emerging eye-banks. Subjective values by the experts closely resembled the measurements by TD. The average correlation between the experts and the non-experts to TD was 0.985 and 0.960 respectively. TD showed higher reproducibility than experts followed by the non-experts. The comparative study showed that increase in thickness reduces the transparency. TD is portable, easy, efficient, maintains sterility and less expensive hence the emerging eye-banks and researchers can use to raise their standards and evaluate the transparency for in vitro tests and comparative studies. The suitable transparency for the cornea deemed for clinical applications was found to be >75 %.

  5. Expanding Boundaries: Current and New Directions in Study Abroad Research and Practice

    Science.gov (United States)

    Marijuan, Silvia; Sanz, Cristina

    2018-01-01

    In spite of advances in the understanding of the effects of the immersion experience on language and cultural development in the last three decades, many questions in study abroad (SA) research remain unanswered. The present article offers a close examination of the field as it is today with an eye toward future trends and gaps in the literature.…

  6. Impact of dry eye on work productivity.

    Science.gov (United States)

    Yamada, Masakazu; Mizuno, Yoshinobu; Shigeyasu, Chika

    2012-01-01

    The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism. A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years) were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed. The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P work productivity loss associated with dry eye was estimated to be USD 741 per person. Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.

  7. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  8. Comparison for aphasic and control subjects of eye movements hypothesized in neurolinguistic programming.

    Science.gov (United States)

    Dooley, K O; Farmer, A

    1988-08-01

    Neurolinguistic programming's hypothesized eye movements were measured independently using videotapes of 10 nonfluent aphasic and 10 control subjects matched for age and sex. Chi-squared analysis indicated that eye-position responses were significantly different for the groups. Although earlier research has not supported the hypothesized eye positions for normal subjects, the present findings support the contention that eye-position responses may differ between neurologically normal and aphasic individuals.

  9. Inferring eye position from populations of lateral intraparietal neurons.

    Science.gov (United States)

    Graf, Arnulf Ba; Andersen, Richard A

    2014-05-20

    Understanding how the brain computes eye position is essential to unraveling high-level visual functions such as eye movement planning, coordinate transformations and stability of spatial awareness. The lateral intraparietal area (LIP) is essential for this process. However, despite decades of research, its contribution to the eye position signal remains controversial. LIP neurons have recently been reported to inaccurately represent eye position during a saccadic eye movement, and to be too slow to support a role in high-level visual functions. We addressed this issue by predicting eye position and saccade direction from the responses of populations of LIP neurons. We found that both signals were accurately predicted before, during and after a saccade. Also, the dynamics of these signals support their contribution to visual functions. These findings provide a principled understanding of the coding of information in populations of neurons within an important node of the cortical network for visual-motor behaviors.DOI: http://dx.doi.org/10.7554/eLife.02813.001. Copyright © 2014, Graf and Andersen.

  10. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  11. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  12. Eye absence does not regulate planarian stem cells during eye regeneration

    OpenAIRE

    LoCascio, Samuel A.; Lapan, Sylvain W.; Reddien, Peter W.

    2017-01-01

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, ...

  13. 3D Dynamic Modeling of the Head-Neck Complex for Fast Eye and Head Orientation Movements Research

    Directory of Open Access Journals (Sweden)

    Daniel A. Sierra

    2011-01-01

    Full Text Available A 3D dynamic computer model for the movement of the head-neck complex is presented. It incorporates anatomically correct information about the diverse elements forming the system. The skeleton is considered as a set of interconnected rigid 3D bodies following the Newton-Euler laws of movement. The muscles are modeled using Enderle's linear model, which shows equivalent dynamic characteristics to Loeb's virtual muscle model. The soft tissues, namely, the ligaments, intervertebral disks, and facet joints, are modeled considering their physiological roles and dynamics. In contrast with other head and neck models developed for safety research, the model is aimed to study the neural control of the complex during fast eye and head movements, such as saccades and gaze shifts. In particular, the time-optimal hypothesis and the feedback control ones are discussed.

  14. Measuring miniature eye movements by means of a SQUID magnetometer

    NARCIS (Netherlands)

    Peters, M.J.; Dunajski, Z.; Meijzssen, T.E.M.; Breukink, E.W.; Wevers-Henke, J.J.

    1982-01-01

    A new technique to measure small eye movements is reported. The precise recording of human eye movements is necessary for research on visual fatigue induced by visual display units.1 So far all methods used have disadvantages: especially those which are sensitive or are rather painful.2,3 Our method

  15. Eye dose assessment and management: overview

    International Nuclear Information System (INIS)

    Rehani, M.M.

    2015-01-01

    Some publications have shown that Hp( 0.07 ) or even Hp( 10 ) can be used as good operational quantities for X-rays in view of difficulties with Hp( 3 ). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 1808 plus cone angle of the X-ray tube and with tube under scan arcs. (authors)

  16. The role of eye fixation in memory enhancement under stress - An eye tracking study.

    Science.gov (United States)

    Herten, Nadja; Otto, Tobias; Wolf, Oliver T

    2017-04-01

    In a stressful situation, attention is shifted to potentially relevant stimuli. Recent studies from our laboratory revealed that participants stressed perform superior in a recognition task involving objects of the stressful episode. In order to characterize the role of a stress induced alteration in visual exploration, the present study investigated whether participants experiencing a laboratory social stress situation differ in their fixation from participants of a control group. Further, we aimed at shedding light on the relation of fixation behaviour with obtained memory measures. We randomly assigned 32 male and 31 female participants to a control or a stress condition consisting of the Trier Social Stress Test (TSST), a public speaking paradigm causing social evaluative threat. In an established 'friendly' control condition (f-TSST) participants talk to a friendly committee. During both conditions, the committee members used ten office items (central objects) while another ten objects were present without being used (peripheral objects). Participants wore eye tracking glasses recording their fixations. On the next day, participants performed free recall and recognition tasks involving the objects present the day before. Stressed participants showed enhanced memory for central objects, accompanied by longer fixation times and larger fixation amounts on these objects. Contrasting this, fixation towards the committee faces showed the reversed pattern; here, control participants exhibited longer fixations. Fixation indices and memory measures were, however, not correlated with each other. Psychosocial stress is associated with altered fixation behaviour. Longer fixation on objects related to the stressful situation may reflect enhanced encoding, whereas diminished face fixation suggests gaze avoidance of aversive, socially threatening stimuli. Modified visual exploration should be considered in future stress research, in particular when focussing on memory for a

  17. Modelling human eye under blast loading.

    Science.gov (United States)

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues.

  18. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.; Rice, B.

    2017-05-01

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

  19. Further Evaluation of a Practitioner Model for Increasing Eye Contact in Children With Autism.

    Science.gov (United States)

    Rapp, John T; Cook, Jennifer L; Nuta, Raluca; Balagot, Carissa; Crouchman, Kayla; Jenkins, Claire; Karim, Sidrah; Watters-Wybrow, Chelsea

    2018-02-01

    Cook et al. recently described a progressive model for teaching children with autism spectrum disorder (ASD) to provide eye contact with an instructor following a name call. The model included the following phases: contingent praise only, contingent edibles plus praise, stimulus prompts plus contingent edibles and praise, contingent video and praise, schedule thinning, generalization assessments, and maintenance evaluations. In the present study, we evaluated the extent to which modifications to the model were needed to train 15 children with ASD to engage in eye contact. Results show that 11 of 15 participants acquired eye contact with the progressive model; however, eight participants required one or more procedural modifications to the model to acquire eye contact. In addition, the four participants who did not acquire eye contact received one or more modifications. Results also show that participants who acquired eye contact with or without modifications continued to display high levels of the behavior during follow-up probes. We discuss directions for future research with and limitations of this progressive model.

  20. Improving College Students English Learning with Dr. Eye Android Mid

    Science.gov (United States)

    Yang, Ju Yin; Che, Pei-Chun

    2015-01-01

    This paper investigates college students' English language learning through use of Dr. Eye Android handheld mobile Internet device (MID). Compared to related studies, students' English learning using MIDs has not been evaluated and fully understood in the field of higher education. Quantitatively, the researchers used TOEIC pretest and posttest to…

  1. Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers

    Science.gov (United States)

    Nakajima, Masashi; Hiraoka, Takahiro; Yamamoto, Toshiya; Takagi, Seiu; Hirohara, Yoko; Oshika, Tetsuro

    2016-01-01

    Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with XY-1 (HOYA Corp.), was the same as that of phakic eyes. The LCA of eyes with ZCB00V (AMO Inc.) was smaller than that of phakic eyes. The LCA of eyes implanted with Alcon’s and HOYA’s IOLs, but not the LCA of eyes implanted with AMO’s IOLs, was positively correlated with the powers of the IOLs. We also performed simulations to verify the impacts of LCA on visual performance for 4-mm pupil diameter; the simulations were a polychromatic modulation transfer function (MTF) and a visual Strehl ratio computed on the basis of an optical transfer function (VSOTF). We concluded that the differences between the LCA of different manufacturers do not affect visual performances when some extent of higher-order aberration (HOA) exists. The smaller HOA of AMO IOLs may enhance visual performance. PMID:27258141

  2. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  3. Dry eye disease: pathophysiology, classification, and diagnosis.

    Science.gov (United States)

    Perry, Henry D

    2008-04-01

    Dry eye disease (DED) is a multifactorial disorder of the tear film and ocular surface that results in eye discomfort, visual disturbance, and often ocular surface damage. Although recent research has made progress in elucidating DED pathophysiology, currently there are no uniform diagnostic criteria. This article discusses the normal anatomy and physiology of the lacrimal functional unit and the tear film; the pathophysiology of DED; DED etiology, classification, and risk factors; and DED diagnosis, including symptom assessment and the roles of selected diagnostic tests.

  4. A Pilot Study: The Efficacy of Virgin Coconut Oil as Ocular Rewetting Agent on Rabbit Eyes

    Directory of Open Access Journals (Sweden)

    Haliza Abdul Mutalib

    2015-01-01

    Full Text Available Purpose. An open-label pilot study of virgin coconut oil (VCO was conducted to determine the safety of the agent as ocular rewetting eye drops on rabbits. Methods. Efficacy of the VCO was assessed by measuring NIBUT, anterior eye assessment, corneal staining, pH, and Schirmer value before instillation and at 30 min, 60 min, and two weeks after instillation. Friedman test was used to analyse any changes in all the measurable variables over the period of time. Results. Only conjunctival redness with instillation of saline agent showed significant difference over the period of time (P0.05. There were no changes in the NIBUT, limbal redness, palpebral conjunctiva redness, corneal staining, pH, and Schirmer value over the period of time for each agent (P>0.05. Conclusion. VCO acts as safe rewetting eye drops as it has shown no significant difference in the measurable parameter compared to commercial brand eye drops and saline. These study data suggest that VCO is safe to be used as ocular rewetting agent on human being.

  5. Image system analysis of human eye wave-front aberration on the basis of HSS

    Science.gov (United States)

    Xu, Ancheng

    2017-07-01

    Hartmann-Shack sensor (HSS) has been used in objective measurement of human eye wave-front aberration, but the research on the effects of sampling point size on the accuracy of the result has not been reported. In this paper, point spread function (PSF) of the whole system mathematical model was obtained via measuring the optical imaging system structure of human eye wave-front aberration measurement. The impact of Airy spot size on the accuracy of system was analyzed. Statistics study show that the geometry of Airy spot size of the ideal light source sent from eye retina formed on the surface of HSS is far smaller than the size of the HSS sample point image used in the experiment. Therefore, the effect of Airy spot on the precision of the system can be ignored. This study theoretically and experimentally justifies the reliability and accuracy of human eye wave-front aberration measurement based on HSS.

  6. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  7. Real-time sharing of gaze data between multiple eye trackers-evaluation, tools, and advice.

    Science.gov (United States)

    Nyström, Marcus; Niehorster, Diederick C; Cornelissen, Tim; Garde, Henrik

    2017-08-01

    Technological advancements in combination with significant reductions in price have made it practically feasible to run experiments with multiple eye trackers. This enables new types of experiments with simultaneous recordings of eye movement data from several participants, which is of interest for researchers in, e.g., social and educational psychology. The Lund University Humanities Laboratory recently acquired 25 remote eye trackers, which are connected over a local wireless network. As a first step toward running experiments with this setup, demanding situations with real time sharing of gaze data were investigated in terms of network performance as well as clock and screen synchronization. Results show that data can be shared with a sufficiently low packet loss (0.1 %) and latency (M = 3 ms, M A D = 2 ms) across 8 eye trackers at a rate of 60 Hz. For a similar performance using 24 computers, the send rate needs to be reduced to 20 Hz. To help researchers conduct similar measurements on their own multi-eye-tracker setup, open source software written in Python and PsychoPy are provided. Part of the software contains a minimal working example to help researchers kick-start experiments with two or more eye trackers.

  8. Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements

    Science.gov (United States)

    Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung

    2014-01-01

    With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315

  9. Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements

    Directory of Open Access Journals (Sweden)

    Jae Won Bang

    2014-09-01

    Full Text Available With the development of 3D displays, user’s eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs, biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR, facial temperature (FT, and a subjective evaluation (SE score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively.

  10. Three-Dimensional Eye Tracking in a Surgical Scenario.

    Science.gov (United States)

    Bogdanova, Rositsa; Boulanger, Pierre; Zheng, Bin

    2015-10-01

    Eye tracking has been widely used in studying the eye behavior of surgeons in the past decade. Most eye-tracking data are reported in a 2-dimensional (2D) fashion, and data for describing surgeons' behaviors on stereoperception are often missed. With the introduction of stereoscopes in laparoscopic procedures, there is an increasing need for studying the depth perception of surgeons under 3D image-guided surgery. We developed a new algorithm for the computation of convergence points in stereovision by measuring surgeons' interpupillary distance, the distance to the view target, and the difference between gaze locations of the 2 eyes. To test the feasibility of our new algorithm, we recruited 10 individuals to watch stereograms using binocular disparity and asked them to develop stereoperception using a cross-eyed viewing technique. Participants' eye motions were recorded by the Tobii eye tracker while they performed the trials. Convergence points between normal and stereo-viewing conditions were computed using the developed algorithm. All 10 participants were able to develop stereovision after a short period of training. During stereovision, participants' eye convergence points were 14 ± 1 cm in front of their eyes, which was significantly closer than the convergence points under the normal viewing condition (77 ± 20 cm). By applying our method of calculating convergence points using eye tracking, we were able to elicit the eye movement patterns of human operators between the normal and stereovision conditions. Knowledge from this study can be applied to the design of surgical visual systems, with the goal of improving surgical performance and patient safety. © The Author(s) 2015.

  11. Acidic mammalian chitinase in dry eye conditions.

    Science.gov (United States)

    Musumeci, Maria; Aragona, Pasquale; Bellin, Milena; Maugeri, Francesco; Rania, Laura; Bucolo, Claudio; Musumeci, Salvatore

    2009-07-01

    An acidic mammalian chitinase (AMCase) seems to be implicated in allergic asthma and allergic ocular pathologies. The aim of this work was to investigate the role of AMCase during Sjögren's Syndrome (SS) and Meibomian Gland Dysfunction (MGD) dry eye diseases. Six patients with MGD dry eye (20-58 years, median 40) and six patients with dry eye associated to SS (32-60 years, median 47) were enrolled in this study. AMCase activity was measured in tears and AMCase mRNA expression was evaluated by real-time polymerase chain reaction from RNA extracted from epithelial cells of the conjunctiva. Six healthy adult subjects of the same age (34-44 years, median 39) were also studied as the control group. AMCase activity was significantly increased in patients affected by MGD dry eye (18.54 +/- 1.5 nmol/ml/h) and SS dry eye (8.94 +/- 1.0 nmol/ml/h) respectively, compared to healthy controls (1.6 +/- 0.2 nmol/ml/h). AMCase activity was higher in the tears of subjects with MGD dry eye (P < 0.001). AMCase mRNA was detected in conjunctival epithelial cells and the expression was significantly higher in MGD dry eye than SS dry eye. A significant correlation between AMCase activity in the tears and mRNA in conjunctival epithelial cells was found. AMCase may be an important marker in the pathogenesis of dry eye, suggesting the potential role of AMCase as a therapeutic target in these frequent pathologies.

  12. Molecular restrictions for human eye irritation by chemical vapors

    International Nuclear Information System (INIS)

    Cometto-Muniz, J. Enrique; Cain, William S.; Abraham, Michael H.

    2005-01-01

    Previous research showed a cut-off along homologous volatile organic compounds (VOCs) in their ability to produce acute human mucosal irritation. The present study sought to specify the particular cut-off homolog for sensory eye irritation in an acetate and n-alcohol series. A 1900-ml glass vessel system and a three-alternative forced-choice procedure served to test nonyl, decyl, and dodecyl acetate, and 1-nonanol, 1-decanol, and 1-undecanol. Flowrate to the eye ranged from 2 to 8 L/min and time of exposure from 3 to 24 s. Decyl acetate and 1-undecanol were the shortest homologs that failed to produce eye irritation under all conditions, producing a cut-off effect. Increasing the vapor concentration of decyl acetate and 1-undecanol by 3 and 8 times, respectively, via heating them to 37 deg C made either or both VOCs detectable to only half of the 12 subjects tested, even though the higher vapor concentration was well above a predicted eye irritation threshold. When eye irritation thresholds for homologous acetates and n-alcohols were plotted as a function of the longest unfolded length of the molecule, the values for decyl acetate and 1-undecanol fell within a restricted range of 18 to 19 A. The outcome suggests that the basis for the cut-off is biological, that is, the molecule lacks a key size or structure to trigger transduction, rather than physical, that is, the vapor concentration is too low to precipitate detection

  13. The Way Dogs (Canis familiaris Look at Human Emotional Faces Is Modulated by Oxytocin. An Eye-Tracking Study

    Directory of Open Access Journals (Sweden)

    Anna Kis

    2017-10-01

    Full Text Available Dogs have been shown to excel in reading human social cues, including facial cues. In the present study we used eye-tracking technology to further study dogs’ face processing abilities. It was found that dogs discriminated between human facial regions in their spontaneous viewing pattern and looked most to the eye region independently of facial expression. Furthermore dogs played most attention to the first two images presented, afterwards their attention dramatically decreases; a finding that has methodological implications. Increasing evidence indicates that the oxytocin system is involved in dogs’ human-directed social competence, thus as a next step we investigated the effects of oxytocin on processing of human facial emotions. It was found that oxytocin decreases dogs’ looking to the human faces expressing angry emotional expression. More interestingly, however, after oxytocin pre-treatment dogs’ preferential gaze toward the eye region when processing happy human facial expressions disappears. These results provide the first evidence that oxytocin is involved in the regulation of human face processing in dogs. The present study is one of the few empirical investigations that explore eye gaze patterns in naïve and untrained pet dogs using a non-invasive eye-tracking technique and thus offers unique but largely untapped method for studying social cognition in dogs.

  14. Natural history of drusenoid pigment epithelial detachment in age-related macular degeneration: Age-Related Eye Disease Study Report No. 28.

    Science.gov (United States)

    Cukras, Catherine; Agrón, Elvira; Klein, Michael L; Ferris, Frederick L; Chew, Emily Y; Gensler, Gary; Wong, Wai T

    2010-03-01

    To describe the natural history of eyes with drusenoid pigment epithelial detachments (DPEDs) associated with age-related macular degeneration (AMD). Multicenter, clinic-based, prospective cohort study. Among 4757 participants enrolled in the Age-Related Eye Disease Study (AREDS), 255 were identified as having DPED in at least 1 eye and having 5 or more years of follow-up after the initial detection of the DPED. Baseline and annual fundus photographs were evaluated for the evolution of the fundus features and the development of advanced AMD in the forms of central geographic atrophy (CGA) or neovascular (NV) AMD. Kaplan-Meier analyses of progression to advanced AMD and of moderate vision loss (> or =15 letters compared with baseline) were performed. Rate of progression to advanced AMD and change in visual acuity from baseline (in terms of mean letters lost and proportion losing > or =15 letters). A total of 311 eyes (from 255 participants) with DPED were followed for a median follow-up time of 8 years subsequent to the initial detection of a DPED. Of the 282 eyes that did not have advanced AMD at baseline, advanced AMD developed within 5 years in 119 eyes (42%) (19% progressing to CGA and 23% progressing to NV-AMD). In the remaining eyes that did not develop advanced AMD (n=163), progressive fundus changes, typified by the development of calcified drusen and pigmentary changes, were detected. Visual decline was prominent among study eyes, with approximately 40% of all eyes decreasing in visual acuity by > or =15 letters at 5 years follow-up. Mean visual acuity decreased from 76 letters ( approximately 20/30) at baseline to 61 letters ( approximately 20/60) at 5 years. Five-year decreases in mean visual acuity averaged 26 letters for eyes progressing to advanced AMD and 8 letters for non-progressing eyes. The natural history of eyes containing DPED is characterized by a high rate of progression to both CGA and NV-AMD. Among eyes not progressing to advanced AMD

  15. Impact of dry eye on work productivity

    Directory of Open Access Journals (Sweden)

    Yamada M

    2012-10-01

    Full Text Available Masakazu Yamada, Yoshinobu Mizuno, Chika ShigeyasuNational Institute of Sensory Organs, National Hospital Organization Tokyo Medical Center, Tokyo, JapanBackground: The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism.Methods: A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed.Results: The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P < 0.05. The annual cost of work productivity loss associated with dry eye was estimated to be USD 741 per person.Conclusion: Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.Keywords: burden of disease, dry eye, presenteeism, quality of life

  16. Perceptions of Eye Health and Eye Health Services among Adults Attending Outreach Eye Care Clinics in Papua New Guinea.

    Science.gov (United States)

    Burnett, Anthea; Yu, Mitasha; Paudel, Prakash; Naduvilath, Thomas; Fricke, Tim R; Hani, Yvonne; Garap, Jambi

    2015-01-01

    To determine how people attending outreach eye care clinics in Papua New Guinea (PNG) perceive eye health and eye health services. An interview-based questionnaire was administrated to a convenience sample of 614 adult participants across four provinces and perceptions of eye health and eye health services were recorded. Presenting and near visual acuity were measured and cause of visual impairment (VI) determined. In this sample, 113/614 participants (18.4%) presented with distance VI, 16 (2.6%) with distance blindness, and 221 (47.6%) with near VI. Older participants and those with near VI were more likely to indicate that it is hard to have an eye examination due to travel time, lack of transport and transport costs. Female participants and those from underserved areas were more likely to report shame and fear of jealousy from others when asked about their attitudes towards spectacles. Participants reporting that they were willing to pay higher amounts for testing and spectacles/treatment also reported higher education levels, higher household incomes and were more likely to be male. A quarter of participants (25.9%) indicated that they did not like having an eye examination because their reading and writing was poor. People attending outreach eye care clinics in PNG reported finding it difficult to attend eye health services due to transport difficulties and anticipated high costs. Negative attitudes towards spectacles were also prevalent, and negative perceptions appeared more frequently among older participants and those with less education.

  17. A Study of Deep CNN-Based Classification of Open and Closed Eyes Using a Visible Light Camera Sensor

    Directory of Open Access Journals (Sweden)

    Ki Wan Kim

    2017-06-01

    Full Text Available The necessity for the classification of open and closed eyes is increasing in various fields, including analysis of eye fatigue in 3D TVs, analysis of the psychological states of test subjects, and eye status tracking-based driver drowsiness detection. Previous studies have used various methods to distinguish between open and closed eyes, such as classifiers based on the features obtained from image binarization, edge operators, or texture analysis. However, when it comes to eye images with different lighting conditions and resolutions, it can be difficult to find an optimal threshold for image binarization or optimal filters for edge and texture extraction. In order to address this issue, we propose a method to classify open and closed eye images with different conditions, acquired by a visible light camera, using a deep residual convolutional neural network. After conducting performance analysis on both self-collected and open databases, we have determined that the classification accuracy of the proposed method is superior to that of existing methods.

  18. Analysis of Eye Care Services in Yemen

    OpenAIRE

    Saleh A. Al-Akily; Mutahar Y. Al-Shaer; Mahfouth A. Bamashmus; Abdulmoghni O. Al-Barrag; Tawfik K. Alkhatib; Hisham A. Al-Akhlee

    2017-01-01

    Purpose: The objective of this study was to undertake an analysis of the eye care services situation in Yemen and to assess ophthalmic human resources, eye units’ ownership and ophthalmic equipments. Methods: Eye care providers were surveyed by a standardized questionnaire which was sent to the 184 eye units in governmental, university, military, private and charity clinics and hospitals in Yemen and covered the period between 01 January to 31 December 2012. The questionnaire determined l...

  19. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  20. New Eye Cleansing Product Improves Makeup-Related Ocular Problems.

    Science.gov (United States)

    Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  1. Individual Differences in Spatial Knowledge Acquisition from a Virtual Environment: An Eye-Tracking Study

    Directory of Open Access Journals (Sweden)

    Ryosuke Uenaka

    2011-05-01

    Full Text Available Previous studies have shown that spatial knowledge acquisition differs across individuals in both real and virtual environments. For example, in a real environment, Ishikawa & Montello (2006 showed that some participants had almost perfect configural knowledge of the environment after one or two learning trials, whereas others performed at chance even after repeated learning trials. Using a virtual version of Ishikawa & Montello's layouts, we measured eye movements while participants were learning a layout of a route, as eye movements are shown to be closely linked to performance in spatial navigation tasks. We prepared three different layouts of a route depicted in a desktop virtual environment, along with the locations of four landmarks on that route. After learning each of the routes, we administered three different measures of spatial knowledge: numbering the landmark order, estimation of direction, and map sketching. Self-reported sense-of-direction (SDQ-S was also measured. Behavioral analyses showed positive correlations across the routes in the estimation of direction. However, consistent correlations were not observed between eye movements and performance of the estimation of direction in each route. Those results suggest that eye movements do not predict individual differences in spatial knowledge acquisition.

  2. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  3. Using eye movements as an index of implicit face recognition in autism spectrum disorder.

    Science.gov (United States)

    Hedley, Darren; Young, Robyn; Brewer, Neil

    2012-10-01

    Individuals with an autism spectrum disorder (ASD) typically show impairment on face recognition tasks. Performance has usually been assessed using overt, explicit recognition tasks. Here, a complementary method involving eye tracking was used to examine implicit face recognition in participants with ASD and in an intelligence quotient-matched non-ASD control group. Differences in eye movement indices between target and foil faces were used as an indicator of implicit face recognition. Explicit face recognition was assessed using old-new discrimination and reaction time measures. Stimuli were faces of studied (target) or unfamiliar (foil) persons. Target images at test were either identical to the images presented at study or altered by changing the lighting, pose, or by masking with visual noise. Participants with ASD performed worse than controls on the explicit recognition task. Eye movement-based measures, however, indicated that implicit recognition may not be affected to the same degree as explicit recognition. Autism Res 2012, 5: 363-379. © 2012 International Society for Autism Research, Wiley Periodicals, Inc. © 2012 International Society for Autism Research, Wiley Periodicals, Inc.

  4. Bilateral saccadic eye movements and tactile stimulation, but not auditory stimulation, enhance memory retrieval

    NARCIS (Netherlands)

    Nieuwenhuis, S.; Elzinga, B.M.; Ras, P.H.; Berends, F.; Duijs, P.; Samara, Z.; Slagter, H.A.

    2013-01-01

    Recent research has shown superior memory retrieval when participants make a series of horizontal saccadic eye movements between the memory encoding phase and the retrieval phase compared to participants who do not move their eyes or move their eyes vertically. It has been hypothesized that the

  5. Attention and choice: a review on eye movements in decision making.

    Science.gov (United States)

    Orquin, Jacob L; Mueller Loose, Simone

    2013-09-01

    This paper reviews studies on eye movements in decision making, and compares their observations to theoretical predictions concerning the role of attention in decision making. Four decision theories are examined: rational models, bounded rationality, evidence accumulation, and parallel constraint satisfaction models. Although most theories were confirmed with regard to certain predictions, none of the theories adequately accounted for the role of attention during decision making. Several observations emerged concerning the drivers and down-stream effects of attention on choice, suggesting that attention processes plays an active role in constructing decisions. So far, decision theories have largely ignored the constructive role of attention by assuming that it is entirely determined by heuristics, or that it consists of stochastic information sampling. The empirical observations reveal that these assumptions are implausible, and that more accurate assumptions could have been made based on prior attention and eye movement research. Future decision making research would benefit from greater integration with attention research. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  7. Classification of visual and linguistic tasks using eye-movement features.

    Science.gov (United States)

    Coco, Moreno I; Keller, Frank

    2014-03-07

    The role of the task has received special attention in visual-cognition research because it can provide causal explanations of goal-directed eye-movement responses. The dependency between visual attention and task suggests that eye movements can be used to classify the task being performed. A recent study by Greene, Liu, and Wolfe (2012), however, fails to achieve accurate classification of visual tasks based on eye-movement features. In the present study, we hypothesize that tasks can be successfully classified when they differ with respect to the involvement of other cognitive domains, such as language processing. We extract the eye-movement features used by Greene et al. as well as additional features from the data of three different tasks: visual search, object naming, and scene description. First, we demonstrated that eye-movement responses make it possible to characterize the goals of these tasks. Then, we trained three different types of classifiers and predicted the task participants performed with an accuracy well above chance (a maximum of 88% for visual search). An analysis of the relative importance of features for classification accuracy reveals that just one feature, i.e., initiation time, is sufficient for above-chance performance (a maximum of 79% accuracy in object naming). Crucially, this feature is independent of task duration, which differs systematically across the three tasks we investigated. Overall, the best task classification performance was obtained with a set of seven features that included both spatial information (e.g., entropy of attention allocation) and temporal components (e.g., total fixation on objects) of the eye-movement record. This result confirms the task-dependent allocation of visual attention and extends previous work by showing that task classification is possible when tasks differ in the cognitive processes involved (purely visual tasks such as search vs. communicative tasks such as scene description).

  8. Autologous serum eye drops for dry eye

    Science.gov (United States)

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  9. Prevalence of dry eye syndrome at patients with diabetus melitus tip 2, one year retrospective study May 2011-June 2012

    Directory of Open Access Journals (Sweden)

    Nora Burda

    2012-01-01

    Conclusions: In our study the Dry Eye Syndrome showed to have a high correlation with Diabetes Mellitus Tip II (about 52.9%. Prevalence of Dry Eye was significantly higher at patients with longer duration of diabetes. Dry Eye seems to be an important contributing factor related to corneal abnormalities. Age and sex not seem to play any important role in this condition. Good glycemic control is important for prevention and control of Dry Eye Syndrome.

  10. Are Serum Vitamin D Levels Associated With Dry Eye Disease? Results From the Study Group for Environmental Eye Disease

    Directory of Open Access Journals (Sweden)

    Da-Hye Jeon

    2017-11-01

    Full Text Available Objectives Dry eye disease (DED is an increasingly important public health problem in Korea. Previous studies conducted in Korea have reported inconsistent results regarding the protective effects of vitamin D on DED, and these discrepancies may be related to the relatively simple questionnaire that has been used. Thus, we evaluated the association of serum vitamin D levels with DED using the ocular surface disease index (OSDI. Methods The present study evaluated data from participants in the Study Group for Environmental Eye Disease (2014-2015. This group included data from 752 participants, and data from 740 participants (253 men and 487 women were analyzed in the present study. DED severity was evaluated using the OSDI. Results Higher serum vitamin D levels were associated with a non-significantly reduced risk of DED in the crude analysis (odds ratio [OR], 0.991; 95% confidence interval [CI], 0.971 to 1.011 and in the adjusted analysis (OR, 0.988; 95% CI, 0.966 to 1.010. In the crude analysis of no/mild DED vs. moderate/severe DED, men exhibited a decreased risk with increasing serum vitamin D levels (OR, 0.999; 95% CI, 0.950 to 1.051, while women exhibited an increased risk (OR, 1.003; 95% CI, 0.979 to 1.027. In these analyses, we found no significant associations. Conclusions The findings of the present study support previous reports that serum vitamin D levels are not associated with DED.

  11. Studies of cytotoxic antibodies against eye muscle antigens in patients with thyroid-associated ophthalmopathy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z.-G.; Hiromatsu, Y.; Salvi, M.; Triller, H.; Bernard, N.; Wall, J.R. (Thyroid Research Unit, The Montreal General Hospital Research Institute, Montreal, Quebec (Canada)); Medeiros-Neto, G.; Iacona, A.; Lima, N. (Thyroid Clinic, Hospital das Clinicas, Sao Paulo (Brazil))

    1989-01-01

    We have studied the prevalence and significance of cytotoxic antibodies against human eye muscle cells, as detected in antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-mediated antibody-dependent cytotoxicity (CMAC) in {sup 51}Cr release assays, in patients with Graves' ophthalmopathy or Hashimoto's thyroiditis. A high prevalence of positive ADCC tests was found in all groups of patients with ophthalmopathy tested. Tests were positive in 64% of patients with Graves' ophthalmopathy from an area of severe iodine deficiency (Sao Paulo) and in 64% of such patients from an iodine replete area (Montreal). In patients with so-called ''euthyroid ophthalmopathy'', i.e. eye disease associated with thyroiditis, ADCC tests were positive in 75 and 38% of patients from the two areas, respectively, while tests were positive in 40 and 22%, respectively, of patients with Graves' hyperthyroidism without evident eye disease. In normal subjects, levels of {sup 51}Cr release was always at background levels. In a group of patients from the high-iodine area, levels of antibodies in ADCC correlated positively with the intraocular pressure (mmHg) in primary position as a parameter of eye muscle dysfunction. In patients with ophthalmopathy, positive ADCC tests were assciated with antibodies to eye muscle membrane antigens of 55,65 and 95 kD as detected by immunoblotting, although the correlation was not close for any antigen. in contrast, CMAC tests were negative in all patients with ophthalmopathy. We also tested 9 mouse and 10 human monoclonal antibodies, reactive with orbital antigens in an enzyme-linked immunosorbent assay, for cytotoxic activity, in ADCC and CMAC, against eye muscle and thyroid cells. All monoclonal antibodies were of the IgM class and negative in ADCC assays. (Abstract Truncated)

  12. An exploratory study on the driving method of speech synthesis based on the human eye reading imaging data

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2016-10-01

    With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.

  13. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  14. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life

    DEFF Research Database (Denmark)

    Rasmussen, Marie Louise Roed

    2010-01-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due...... to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. THE PURPOSE OF THE PHD THESIS WAS: To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique...... and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity...

  15. Eye shape and the nocturnal bottleneck of mammals.

    Science.gov (United States)

    Hall, Margaret I; Kamilar, Jason M; Kirk, E Christopher

    2012-12-22

    Most vertebrate groups exhibit eye shapes that vary predictably with activity pattern. Nocturnal vertebrates typically have large corneas relative to eye size as an adaptation for increased visual sensitivity. Conversely, diurnal vertebrates generally demonstrate smaller corneas relative to eye size as an adaptation for increased visual acuity. By contrast, several studies have concluded that many mammals exhibit typical nocturnal eye shapes, regardless of activity pattern. However, a recent study has argued that new statistical methods allow eye shape to accurately predict activity patterns of mammals, including cathemeral species (animals that are equally likely to be awake and active at any time of day or night). Here, we conduct a detailed analysis of eye shape and activity pattern in mammals, using a broad comparative sample of 266 species. We find that the eye shapes of cathemeral mammals completely overlap with nocturnal and diurnal species. Additionally, most diurnal and cathemeral mammals have eye shapes that are most similar to those of nocturnal birds and lizards. The only mammalian clade that diverges from this pattern is anthropoids, which have convergently evolved eye shapes similar to those of diurnal birds and lizards. Our results provide additional evidence for a nocturnal 'bottleneck' in the early evolution of crown mammals.

  16. Prevalence and risk factors for visual impairment in preschool children the sydney paediatric eye disease study.

    Science.gov (United States)

    Pai, Amy Shih-I; Wang, Jie Jin; Samarawickrama, Chameen; Burlutsky, George; Rose, Kathryn A; Varma, Rohit; Wong, Tien Yin; Mitchell, Paul

    2011-08-01

    To assess the prevalence and associations of visual impairment (VI) in preschool children. Cross-sectional, population-based study. A total of 2461 children (73.8% participation rate), aged 6 to 72 months, were examined in the Sydney Paediatric Eye Disease Study during 2007-2009; of whom 1188, aged 30 to 72 months, with complete visual acuity (VA) data in both eyes, were included in this report. Measurement of VA was attempted on all children using the Electronic Visual Acuity (EVA) system or a logarithm of the minimum angle of resolution (logMAR) chart. Visual impairment was defined as presenting VA children aged ≥48 months and Visual impairment prevalence and its associations with child demographic factors and birth parameters. Visual impairment was found in 6.4% of the worse eye and 2.7% of the better eye in our sample. Refractive errors (69.7%) and amblyopia (26.3%) were the principal causes of VI in the worse eye. Astigmatism (51.3%) and hyperopia (28.9%) were the main refractive errors causing VI. In regression analysis controlling for other factors, VI was independently associated with low birthweight of 0.05). Visual impairment in at least 1 eye was found in 6.4% of Australian preschool children, with bilateral VI found in 2.7%. Uncorrected refractive errors and amblyopia were the principal ocular conditions associated with VI. Low birthweight was a significant risk factor independent of age, gender, and ethnicity. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Constraining eye movement in individuals with Parkinson's disease during walking turns.

    Science.gov (United States)

    Ambati, V N Pradeep; Saucedo, Fabricio; Murray, Nicholas G; Powell, Douglas W; Reed-Jones, Rebecca J

    2016-10-01

    Walking and turning is a movement that places individuals with Parkinson's disease (PD) at increased risk for fall-related injury. However, turning is an essential movement in activities of daily living, making up to 45 % of the total steps taken in a given day. Hypotheses regarding how turning is controlled suggest an essential role of anticipatory eye movements to provide feedforward information for body coordination. However, little research has investigated control of turning in individuals with PD with specific consideration for eye movements. The purpose of this study was to examine eye movement behavior and body segment coordination in individuals with PD during walking turns. Three experimental groups, a group of individuals with PD, a group of healthy young adults (YAC), and a group of healthy older adults (OAC), performed walking and turning tasks under two visual conditions: free gaze and fixed gaze. Whole-body motion capture and eye tracking characterized body segment coordination and eye movement behavior during walking trials. Statistical analysis revealed significant main effects of group (PD, YAC, and OAC) and visual condition (free and fixed gaze) on timing of segment rotation and horizontal eye movement. Within group comparisons, revealed timing of eye and head movement was significantly different between the free and fixed gaze conditions for YAC (p  0.05). In addition, while intersegment timings (reflecting segment coordination) were significantly different for YAC and OAC during free gaze (p training programs for those with PD, possibly promoting better coordination during turning and potentially reducing the risk of falls.

  18. Searching for the prototypic eye genetic network: Sine oculis is essential for eye regeneration in planarians

    Science.gov (United States)

    Pineda, D.; Gonzalez, J.; Callaerts, P.; Ikeo, K.; Gehring, W. J.; Salo, E.

    2000-01-01

    We have identified a sine oculis gene in the planarian Girardia tigrina (Platyhelminthes; Turbellaria; Tricladida). The planarian sine oculis gene (Gtso) encodes a protein with a sine oculis (Six) domain and a homeodomain that shares significant sequence similarity with so proteins assigned to the Six-2 gene family. Gtso is expressed as a single transcript in both regenerating and fully developed eyes. Whole-mount in situ hybridization studies show exclusive expression in photoreceptor cells. Loss of function of Gtso by RNA interference during planarian regeneration inhibits eye regeneration completely. Gtso is also essential for maintenance of the differentiated state of photoreceptor cells. These results, combined with the previously demonstrated expression of Pax-6 in planarian eyes, suggest that the same basic gene regulatory circuit required for eye development in Drosophila and mouse is used in the prototypic eye spots of platyhelminthes and, therefore, is truly conserved during evolution. PMID:10781056

  19. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  20. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  1. Directionality of large-scale resting-state brain networks during eyes open and eyes closed conditions

    NARCIS (Netherlands)

    Zhang, Delong; Liang, Bishan; Wu, Xia; Wang, Zengjian; Xu, Pengfei; Chang, Song; Liu, Bo; Liu, Ming; Huang, Ruiwang

    2015-01-01

    The present study examined directional connections in the brain among resting-state networks (RSNs) when the participant had their eyes open (E0) or had their eyes closed (EC). The resting state fMRI data were collected from 20 healthy participants (9 males, 20.17 +/- 2.74 years) under the EO and EC

  2. Eye movements during listening reveal spontaneous grammatical processing.

    Science.gov (United States)

    Huette, Stephanie; Winter, Bodo; Matlock, Teenie; Ardell, David H; Spivey, Michael

    2014-01-01

    Recent research using eye-tracking typically relies on constrained visual contexts in particular goal-oriented contexts, viewing a small array of objects on a computer screen and performing some overt decision or identification. Eyetracking paradigms that use pictures as a measure of word or sentence comprehension are sometimes touted as ecologically invalid because pictures and explicit tasks are not always present during language comprehension. This study compared the comprehension of sentences with two different grammatical forms: the past progressive (e.g., was walking), which emphasizes the ongoing nature of actions, and the simple past (e.g., walked), which emphasizes the end-state of an action. The results showed that the distribution and timing of eye movements mirrors the underlying conceptual structure of this linguistic difference in the absence of any visual stimuli or task constraint: Fixations were shorter and saccades were more dispersed across the screen, as if thinking about more dynamic events when listening to the past progressive stories. Thus, eye movement data suggest that visual inputs or an explicit task are unnecessary to solicit analog representations of features such as movement, that could be a key perceptual component to grammatical comprehension.

  3. Eye movements during listening reveal spontaneous grammatical processing

    Directory of Open Access Journals (Sweden)

    Stephanie eHuette

    2014-05-01

    Full Text Available Recent research using eye-tracking typically relies on constrained visual contexts in particular goal-oriented contexts, viewing a small array of objects on a computer screen and performing some overt decision or identification. Eyetracking paradigms that use pictures as a measure of word or sentence comprehension are sometimes touted as ecologically invalid because pictures and explicit tasks are not always present during language comprehension. This study compared the comprehension of sentences with two different grammatical forms: the past progressive (e.g., was walking, which emphasizes the ongoing nature of actions, and the simple past (e.g., walked, which emphasizes the end-state of an action. The results showed that the distribution and timing of eye movements mirrors the underlying conceptual structure of this linguistic difference in the absence of any visual stimuli or task constraint: Fixations were shorter and saccades were more dispersed across the screen, as if thinking about more dynamic events when listening to the past progressive stories. Thus, eye movement data suggest that visual inputs or an explicit task are unnecessary to solicit analogue representations of features such as movement, that could be a key perceptual component to grammatical comprehension.

  4. An Eye-tracking Study of Notational, Informational, and Emotional Aspects of Learning Analytics Representations

    DEFF Research Database (Denmark)

    Vatrapu, Ravi; Reimann, Peter; Bull, Susan

    2013-01-01

    This paper presents an eye-tracking study of notational, informational, and emotional aspects of nine different notational systems (Skill Meters, Smilies, Traffic Lights, Topic Boxes, Collective Histograms, Word Clouds, Textual Descriptors, Table, and Matrix) and three different information states...... (Weak, Average, & Strong) used to represent student's learning. Findings from the eye-tracking study show that higher emotional activation was observed for the metaphorical notations of traffic lights and smilies and collective representations. Mean view time was higher for representations...... of the "average" informational learning state. Qualitative data analysis of the think-aloud comments and post-study interview show that student participants reflected on the meaning-making opportunities and action-taking possibilities afforded by the representations. Implications for the design and evaluation...

  5. SPECTRUM OF CHILDHOOD EYE DISEASES IN A RURAL MEDICAL COLLEGE- A RETROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Vinayaga Murthy K

    2017-05-01

    Full Text Available BACKGROUND Eye disorders in children with different presentations come to Ophthalmology OPD. Early detection and treatment of ocular morbidity is important. This study aimed to detect the prevalence and pattern of common ophthalmic problems in paediatric age group, in a rural based tertiary care hospital. MATERIALS AND METHODS Study design was observational, retrospective review of all children less than 12 yrs. old, who came to the rural based Chengalpattu Government medical college Ophthalmology OPD, between September 2015 and May 2016. Data collection and analysis was based on the age of presentation of both sexes (newborn (0-28 days, infants (1 year, preschool (1-5 years, school going (above 5 years from rural and semi-rural areas and diagnosis were analysed using graph pad prism 5.0. 'P value' less than 0.05 was considered statistically significant. RESULTS During the study period, out of total 2520 OP cases (100%, 230 children (10.95% were evaluated. The male: Female ratio was 1.1:1. The children from school going age constituted the largest group, male (48 .4% & Female (51.5% (p<0.001. Children from semi-rural area constituted (55% and rural area constituted (45%. Defective vision (26% was the common complaint, eye discharge accounts for (20%, and lid swelling accounts for (11.3 %. Common conditions were refractive error (26%, Conjunctivitis (20%, Lid Inflammations (11.3%, and Injuries for (10.3%. Refractive Error was common in females (53.3% and in school going children (60 %. Myopia (85% was the common refractive error. Conjunctivitis was seen more in males (52.17% and less in females (47.8%. In pre-school age group conjunctivitis was common. CONCLUSION The common childhood eye diseases observed in our study is refractive error. This has led to poor scholastic performance in school and absenteeism. Health Education & Environmental Hygiene will help in managing most of these eye disorders.

  6. New Eye Cleansing Product Improves Makeup-Related Ocular Problems

    Directory of Open Access Journals (Sweden)

    Masako Okura

    2015-01-01

    Full Text Available Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  7. Automatic emotional expression analysis from eye area

    Science.gov (United States)

    Akkoç, Betül; Arslan, Ahmet

    2015-02-01

    Eyes play an important role in expressing emotions in nonverbal communication. In the present study, emotional expression classification was performed based on the features that were automatically extracted from the eye area. Fırst, the face area and the eye area were automatically extracted from the captured image. Afterwards, the parameters to be used for the analysis through discrete wavelet transformation were obtained from the eye area. Using these parameters, emotional expression analysis was performed through artificial intelligence techniques. As the result of the experimental studies, 6 universal emotions consisting of expressions of happiness, sadness, surprise, disgust, anger and fear were classified at a success rate of 84% using artificial neural networks.

  8. New Perspectives on Dry Eye Definition and Diagnosis: A Consensus Report by the Asia Dry Eye Society.

    Science.gov (United States)

    Tsubota, Kazuo; Yokoi, Norihiko; Shimazaki, Jun; Watanabe, Hitoshi; Dogru, Murat; Yamada, Masakazu; Kinoshita, Shigeru; Kim, Hyo-Myung; Tchah, Hung-Won; Hyon, Joon Young; Yoon, Kyung-Chul; Seo, Kyoung Yul; Sun, Xuguang; Chen, Wei; Liang, Lingyi; Li, Mingwu; Liu, Zuguo

    2017-01-01

    For the last 20 years, a great amount of evidence has accumulated through epidemiological studies that most of the dry eye disease encountered in daily life, especially in video display terminal (VDT) workers, involves short tear film breakup time (TFBUT) type dry eye, a category characterized by severe symptoms but minimal clinical signs other than short TFBUT. An unstable tear film also affects the visual function, possibly due to the increase of higher order aberrations. Based on the change in the understanding of the types, symptoms, and signs of dry eye disease, the Asia Dry Eye Society agreed to the following definition of dry eye: "Dry eye is a multifactorial disease characterized by unstable tear film causing a variety of symptoms and/or visual impairment, potentially accompanied by ocular surface damage." The definition stresses instability of the tear film as well as the importance of visual impairment, highlighting an essential role for TFBUT assessment. This paper discusses the concept of Tear Film Oriented Therapy (TFOT), which evolved from the definition of dry eye, emphasizing the importance of a stable tear film. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  9. Investigation of extended blinks and interblink intervals in subjects with and without dry eye

    Directory of Open Access Journals (Sweden)

    Rodriguez JD

    2013-02-01

    Full Text Available John D Rodriguez,1 George W Ousler III,1 Patrick R Johnston,1 Keith Lane,1 Mark B Abelson1,21Ora, Inc, Andover, MA, 2Schepens Eye Research Institute and Harvard Medical School, Boston, MA, USABackground: The purpose of this study was to investigate the occurrence and duration of extended blinks ≥ 70 msec and their associated interblink intervals in normal subjects and in subjects with mild to moderate dry eye.Methods: This single-center, prospective, double-blind study included 11 subjects with dry eye and eight subjects with normal eyes. Extended blinks were defined as lid closure in at least two successive video frames (≥ 70 msec. Digital video imaging of each subject's eyes was recorded while the subject viewed a 10-minute documentary. The subjects did not know that blink was the outcome being measured. Following capture, the videos were manually analyzed in a masked fashion for the occurrence of extended blinks. The length of the interblink interval (ie, time between blinks before and after these extended blinks (the interblink interval ratio was calculated, as well as differences in lid contact times.Results: The dry eye group had a median extended blink duration which was 2.53 times longer than that of the normal group. For subjects with dry eye, interblink intervals post-extended blink were significantly longer than interblink intervals pre-extended blink (P < 0.001. Interblink intervals did not lengthen significantly in normal subjects. In both groups, the duration of the extended blink was significantly (P = 0.001 and positively correlated with interblink interval ratio (post-extended to pre-extended blink interblink interval, such that for each doubling of extended blink duration, the interblink interval ratio increased by 10%. Blinks longer than one second in duration occurred almost exclusively in subjects with dry eye.Conclusion: This study reports three central findings: blink duration tended to be longer in subjects with dry

  10. Efficiency of optical-electronic systems: methods application for the analysis of structural changes in the process of eye grounds diagnosis

    Science.gov (United States)

    Saldan, Yosyp R.; Pavlov, Sergii V.; Vovkotrub, Dina V.; Saldan, Yulia Y.; Vassilenko, Valentina B.; Mazur, Nadia I.; Nikolaichuk, Daria V.; Wójcik, Waldemar; Romaniuk, Ryszard; Suleimenov, Batyrbek; Bainazarov, Ulan

    2017-08-01

    Process of eye tomogram obtaining by means of optical coherent tomography is studied. Stages of idiopathic macula holes formation in the process of eye grounds diagnostics are considered. Main stages of retina pathology progression are determined: Fuzzy logic units for obtaining reliable conclusions regarding the result of diagnosis are developed. By the results of theoretical and practical research system and technique of retinal macular region of the eye state analysis is developed ; application of the system, based on fuzzy logic device, improves the efficiency of eye retina complex.

  11. Herpetic Eye Disease in a Public Eye Hospital in Nigeria | Nwosu ...

    African Journals Online (AJOL)

    Objective: To determine the aetiology, pattern and complications of herpetic eye disease seen at the Guinness Eye Centre, Onitsha, Nigeria. Materials and Methods: The case files of all patients with herpetic eye disease who presented at the centre between January 1998 and December 2003 were reviewed. Information on ...

  12. Research of Digital Interface Layout Design based on Eye-tracking

    OpenAIRE

    Shao Jiang; Xue Chengqi; Wang Fang; Wang Haiyan; Tang Wencheng; Chen Mo; Kang Mingwu

    2015-01-01

    The aim of this paper is to improve the low service efficiency and unsmooth human-computer interaction caused by currently irrational layouts of digital interfaces for complex systems. Also, three common layout structures for digital interfaces are to be presented and five layout types appropriate for multilevel digital interfaces are to be summarized. Based on the eye tracking technology, an assessment was conducted in advantages and disadvantages of different layout types through subjects’ ...

  13. Eyes wide shut: amygdala mediates eyes-closed effect on emotional experience with music.

    Science.gov (United States)

    Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma

    2009-07-15

    The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, 'low', visceral-, and 'high', cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. 'low') and cognitive (i.e. 'high') related processes of emotions.

  14. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  15. Rapid eye movement-sleep is reduced in patients with acute uncomplicated diverticulitis—an observational study

    Directory of Open Access Journals (Sweden)

    Chenxi Huang

    2015-08-01

    Full Text Available Introduction. Sleep disturbances are commonly found in patients in the postoperative period. Sleep disturbances may give rise to several complications including cardiopulmonary instability, transient cognitive dysfunction and prolonged convalescence. Many factors including host inflammatory responses are believed to cause postoperative sleep disturbances, as inflammatory responses can alter sleep architecture through cytokine-brain interactions. Our aim was to investigate alteration of sleep architecture during acute infection and its relationships to inflammation and clinical symptoms.Materials & Methods. In this observational study, we included patients with acute uncomplicated diverticulitis as a model to investigate the isolated effects of inflammatory responses on sleep. Eleven patients completed the study. Patients were admitted and treated with antibiotics for two nights, during which study endpoints were measured by polysomnography recordings, self-reported discomfort scores and blood samples of cytokines. One month later, the patients, who now were in complete remission, were readmitted and the endpoints were re-measured (the baseline values.Results. Total sleep time was reduced 4% and 7% the first (p = 0.006 and second (p = 0.014 nights of diverticulitis, compared to baseline, respectively. The rapid eye movement sleep was reduced 33% the first night (p = 0.016, compared to baseline. Moreover, plasma IL-6 levels were correlated to non-rapid eye movement sleep, rapid eye movement sleep and fatigue.Conclusion. Total sleep time and rapid eye movement sleep were reduced during nights with active diverticulitis and correlated with markers of inflammation.

  16. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom.

    Science.gov (United States)

    Lesperance, Marielle; Inglis-Whalen, M; Thomson, R M

    2014-02-01

    To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with(125)I, (103)Pd, or (131)Cs seeds, and to investigate doses to ocular structures. An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20-30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%-10% and 13%-14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%-17% and 29%-34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model

  17. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    International Nuclear Information System (INIS)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-01-01

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with 125 I, 103 Pd, or 131 Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up

  18. Characterisation of the porcine eyeball as an in-vitro model for dry eye.

    Science.gov (United States)

    Menduni, Francesco; Davies, Leon N; Madrid-Costa, D; Fratini, Antonio; Wolffsohn, James S

    2018-02-01

    To characterise the anatomical parameters of the porcine eye for potentially using it as a laboratory model of dry eye. Anterior chamber depth and angle, corneal curvature, shortest and longest diameter, endothelial cell density, and pachymetry were measured in sixty freshly enucleated porcine eyeballs. Corneal steepest meridian was 7.85±0.32mm, corneal flattest meridian was 8.28±0.32mm, shortest corneal diameter was 12.69±0.58mm, longest corneal diameter was 14.88±0.66mm and central corneal ultrasonic pachymetry was 1009±1μm. Anterior chamber angle was 28.83±4.16°, anterior chamber depth was 1.77±0.27mm, and central corneal thickness measured using OCT was 1248±144μm. Corneal endothelial cell density was 3250±172 cells/mm 2 . Combining different clinical techniques produced a pool of reproducible data on the porcine eye anatomy, which can be used by researchers to assess the viability of using the porcine eye as an in-vitro/ex-vivo model for dry eye. Due to the similar morphology with the human eye, porcine eyeballs may represent a useful and cost effective model to individually study important key factors in the development of dry eye, such as environmental and mechanical stresses. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Degeneration of rapid eye movement sleep circuitry underlies rapid eye movement sleep behavior disorder.

    Science.gov (United States)

    McKenna, Dillon; Peever, John

    2017-05-01

    During healthy rapid eye movement sleep, skeletal muscles are actively forced into a state of motor paralysis. However, in rapid eye movement sleep behavior disorder-a relatively common neurological disorder-this natural process is lost. A lack of motor paralysis (atonia) in rapid eye movement sleep behavior disorder allows individuals to actively move, which at times can be excessive and violent. At first glance this may sound harmless, but it is not because rapid eye movement sleep behavior disorder patients frequently injure themselves or the person they sleep with. It is hypothesized that the degeneration or dysfunction of the brain stem circuits that control rapid eye movement sleep paralysis is an underlying cause of rapid eye movement sleep behavior disorder. The link between brain stem degeneration and rapid eye movement sleep behavior disorder stems from the fact that rapid eye movement sleep behavior disorder precedes, in the majority (∼80%) of cases, the development of synucleinopathies such as Parkinson's disease, dementia with Lewy bodies, and multiple system atrophy, which are known to initially cause degeneration in the caudal brain stem structures where rapid eye movement sleep circuits are located. Furthermore, basic science and clinical evidence demonstrate that lesions within the rapid eye movement sleep circuits can induce rapid eye movement sleep-specific motor deficits that are virtually identical to those observed in rapid eye movement sleep behavior disorder. This review examines the evidence that rapid eye movement sleep behavior disorder is caused by synucleinopathic neurodegeneration of the core brain stem circuits that control healthy rapid eye movement sleep and concludes that rapid eye movement sleep behavior disorder is not a separate clinical entity from synucleinopathies but, rather, it is the earliest symptom of these disorders. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and

  20. Two Eyes, 3D: A New Project to Study Stereoscopy in Astronomy Education

    Science.gov (United States)

    Price, Aaron; SubbaRao, M.; Wyatt, R.

    2012-01-01

    "Two Eyes, 3D" is a 3-year NSF funded research project to study the educational impacts of using stereoscopic representations in informal settings. The project funds two experimental studies. The first is focused on how children perceive various spatial qualities of scientific objects displayed in static 2D and 3D formats. The second is focused on how adults perceive various spatial qualities of scientific objects and processes displayed in 2D and 3D movie formats. As part of the project, two brief high-definition films about variable stars will be developed. Both studies will be mixed-method and look at prior spatial ability and other demographic variables as covariates. The project is run by the American Association of Variable Star Observers, Boston Museum of Science and the Adler Planetarium and Astronomy Museum with consulting from the California Academy of Sciences. Early pilot results will be presented. All films will be released into the public domain, as will the assessment software designed to run on tablet computers (iOS or Android).

  1. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  2. Choosing Wisely When It Comes to Eye Care: Antibiotics for Eye Injections

    Science.gov (United States)

    ... Antibiotics for eye injections; and Punctal plugs for dry eye . This is the fourth in a series of ... why patients and their ophthalmologists should discuss treating dry eye with punctal plugs only after other treatment options ...

  3. The analysis of the influence of fractal structure of stimuli on fractal dynamics in fixational eye movements and EEG signal

    Science.gov (United States)

    Namazi, Hamidreza; Kulish, Vladimir V.; Akrami, Amin

    2016-05-01

    One of the major challenges in vision research is to analyze the effect of visual stimuli on human vision. However, no relationship has been yet discovered between the structure of the visual stimulus, and the structure of fixational eye movements. This study reveals the plasticity of human fixational eye movements in relation to the ‘complex’ visual stimulus. We demonstrated that the fractal temporal structure of visual dynamics shifts towards the fractal dynamics of the visual stimulus (image). The results showed that images with higher complexity (higher fractality) cause fixational eye movements with lower fractality. Considering the brain, as the main part of nervous system that is engaged in eye movements, we analyzed the governed Electroencephalogram (EEG) signal during fixation. We have found out that there is a coupling between fractality of image, EEG and fixational eye movements. The capability observed in this research can be further investigated and applied for treatment of different vision disorders.

  4. Spectacle-related eye injuries, spectacle-impact performance and eye protection.

    Science.gov (United States)

    Hoskin, Annette K; Philip, Swetha; Dain, Stephen J; Mackey, David A

    2015-05-01

    The aim was to review the prevalence of spectacle-related ocular trauma and the performance of currently available spectacle materials and to identify the risk factors associated with spectacle-related ocular trauma. A literature review was conducted using Medline, Embase and Google with the keywords 'eyeglasses' OR 'spectacles' AND 'ocular injury' / 'eye injury'/ 'eye trauma' / 'ocular trauma'. Articles published prior to 1975 were excluded from this review because of advances in spectacle lens technology and Food and Drug Administration legislative changes requiring impact resistance of all prescription spectacle lenses in the United States. Six hundred and ninety-five individual ocular traumas, for which spectacles contributed to or were the main cause of injury, were identified in the literature. Eye injuries occurred when spectacles were worn in sports, in which medium- to high-impact energies were exerted from balls, racquets or bats and/or as a result of a collision with another player. Frame, lens design and product material choice were found to be associated with ocular injury, with polycarbonate lenses cited as the material of choice in the literature. International, regional and national standards for spectacle lenses had a wide range of impact requirements for prescription spectacle lenses, sports eye protection and occupational eye protection. Spectacle-related injury represents a small but preventable cause of ocular injury. With the increasing numbers of spectacle wearers and calls to spend more time outdoors to reduce myopia, spectacle wearers need to be made aware of the potential risks associated with wearing spectacles during medium- to high-risk activities. At particular risk are those prone to falls, the functionally one-eyed, those who have corneal thinning or have had previous eye surgery or injury. With increased understanding of specific risk factors, performance guidelines can be developed for prescription spectacle eye

  5. Bilateral Saccadic Eye Movements and Tactile Stimulation, but Not Auditory Stimulation, Enhance Memory Retrieval

    Science.gov (United States)

    Nieuwenhuis, Sander; Elzinga, Bernet M.; Ras, Priscilla H.; Berends, Floris; Duijs, Peter; Samara, Zoe; Slagter, Heleen A.

    2013-01-01

    Recent research has shown superior memory retrieval when participants make a series of horizontal saccadic eye movements between the memory encoding phase and the retrieval phase compared to participants who do not move their eyes or move their eyes vertically. It has been hypothesized that the rapidly alternating activation of the two hemispheres…

  6. Maxwellian Eye Fixation during Natural Scene Perception

    Directory of Open Access Journals (Sweden)

    Jean Duchesne

    2012-01-01

    Full Text Available When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell’s law for each participant and for each scene condition (normal or scrambled. The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes.

  7. Maxwellian Eye Fixation during Natural Scene Perception

    Science.gov (United States)

    Duchesne, Jean; Bouvier, Vincent; Guillemé, Julien; Coubard, Olivier A.

    2012-01-01

    When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF) of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell's law for each participant and for each scene condition (normal or scrambled). The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes. PMID:23226987

  8. The development of eye tracking in aviation (ETA) technique to investigate pilot's cognitive processes of attention and decision-making

    OpenAIRE

    Li, Wen-Chin; Lin, John J. H.; Braithwaite, Graham; Greaves, Matt

    2016-01-01

    Eye tracking device had provided researchers a promising way to investigate what pilot‘s cognitive processes when they see information present on the flight deck. There are 35 participants consisted by pilots and avionics engineers participated in current research. The research apparatus include an eye tracker and a flight simulator divided by five AOIs for data collection. The research aims are to develop cost-efficiency of eye tracking technique in order to facilitate scientific research of...

  9. The effect of emotionally valenced eye region images on visuocortical processing of surprised faces.

    Science.gov (United States)

    Li, Shuaixia; Li, Ping; Wang, Wei; Zhu, Xiangru; Luo, Wenbo

    2018-05-01

    In this study, we presented pictorial representations of happy, neutral, and fearful expressions projected in the eye regions to determine whether the eye region alone is sufficient to produce a context effect. Participants were asked to judge the valence of surprised faces that had been preceded by a picture of an eye region. Behavioral results showed that affective ratings of surprised faces were context dependent. Prime-related ERPs with presentation of happy eyes elicited a larger P1 than those for neutral and fearful eyes, likely due to the recognition advantage provided by a happy expression. Target-related ERPs showed that surprised faces in the context of fearful and happy eyes elicited dramatically larger C1 than those in the neutral context, which reflected the modulation by predictions during the earliest stages of face processing. There were larger N170 with neutral and fearful eye contexts compared to the happy context, suggesting faces were being integrated with contextual threat information. The P3 component exhibited enhanced brain activity in response to faces preceded by happy and fearful eyes compared with neutral eyes, indicating motivated attention processing may be involved at this stage. Altogether, these results indicate for the first time that the influence of isolated eye regions on the perception of surprised faces involves preferential processing at the early stages and elaborate processing at the late stages. Moreover, higher cognitive processes such as predictions and attention can modulate face processing from the earliest stages in a top-down manner. © 2017 Society for Psychophysiological Research.

  10. Parent Perception of Two Eye-Gaze Control Technology Systems in Young Children with Cerebral Palsy: Pilot Study.

    Science.gov (United States)

    Karlsson, Petra; Wallen, Margaret

    2017-01-01

    Eye-gaze control technology enables people with significant physical disability to access computers for communication, play, learning and environmental control. This pilot study used a multiple case study design with repeated baseline assessment and parents' evaluations to compare two eye-gaze control technology systems to identify any differences in factors such as ease of use and impact of the systems for their young children. Five children, aged 3 to 5 years, with dyskinetic cerebral palsy, and their families participated. Overall, families were satisfied with both the Tobii PCEye Go and myGaze® eye tracker, found them easy to position and use, and children learned to operate them quickly. This technology provides young children with important opportunities for learning, play, leisure, and developing communication.

  11. Effects of Punctal Occlusion on Clinical Signs and Symptoms and on Tear Cytokine Levels in Patients with Dry Eye.

    Science.gov (United States)

    Tong, Louis; Beuerman, Roger; Simonyi, Susan; Hollander, David A; Stern, Michael E

    2016-04-01

    To investigate changes in signs, symptoms, and tear cytokines following punctal plug occlusion in patients with dry eye. A single-center study was conducted at Singapore Eye Research Institute. Nonabsorbable punctal plugs were inserted in the lower punctum of both eyes in patients with moderate dry eye. Over 3 weeks, in the more severe eye, dry eye symptoms, fluorescein corneal staining, Schirmer I (without topical anesthesia) test, tear film breakup time (TFBUT), and safety were assessed. Cytokine and matrix metalloproteinase-9 (MMP-9) levels in tear samples were measured. Twenty-nine patients (mean age 49.8 years) with moderate dry eye were evaluated. At baseline, mean (standard deviation) global symptoms score was 53.8 (26.5), Schirmer I test score was 5.1 (2.8) mm, and TFBUT was 2.2 (0.6) seconds. After 3 weeks, punctal occlusion significantly reduced global irritation symptoms score (Pdry eye disease. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Evaluation of Color Settings in Aerial Images with the Use of Eye-Tracking User Study

    Science.gov (United States)

    Mirijovsky, J.; Popelka, S.

    2016-06-01

    The main aim of presented paper is to find the most realistic and preferred color settings for four different types of surfaces on the aerial images. This will be achieved through user study with the use of eye-movement recording. Aerial images taken by the unmanned aerial system were used as stimuli. From each image, squared crop area containing one of the studied types of surfaces (asphalt, concrete, water, soil, and grass) was selected. For each type of surface, the real value of reflectance was found with the use of precise spectroradiometer ASD HandHeld 2 which measures the reflectance. The device was used at the same time as aerial images were captured, so lighting conditions and state of vegetation were equal. The spectral resolution of the ASD device is better than 3.0 nm. For defining the RGB values of selected type of surface, the spectral reflectance values recorded by the device were merged into wider groups. Finally, we get three groups corresponding to RGB color system. Captured images were edited with the graphic editor Photoshop CS6. Contrast, clarity, and brightness were edited for all surface types on images. Finally, we get a set of 12 images of the same area with different color settings. These images were put into the grid and used as stimuli for the eye-tracking experiment. Eye-tracking is one of the methods of usability studies and it is considered as relatively objective. Eye-tracker SMI RED 250 with the sampling frequency 250 Hz was used in the study. As respondents, a group of 24 students of Geoinformatics and Geography was used. Their task was to select which image in the grid has the best color settings. The next task was to select which color settings they prefer. Respondents' answers were evaluated and the most realistic and most preferable color settings were found. The advantage of the eye-tracking evaluation was that also the process of the selection of the answers was analyzed. Areas of Interest were marked around each image in the

  13. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    OpenAIRE

    J. J. Gu; M. Meng; A. Cook; P. X. Liu

    2006-01-01

    Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the contro...

  14. Reasoning strategies with rational numbers revealed by eye tracking.

    Science.gov (United States)

    Plummer, Patrick; DeWolf, Melissa; Bassok, Miriam; Gordon, Peter C; Holyoak, Keith J

    2017-07-01

    Recent research has begun to investigate the impact of different formats for rational numbers on the processes by which people make relational judgments about quantitative relations. DeWolf, Bassok, and Holyoak (Journal of Experimental Psychology: General, 144(1), 127-150, 2015) found that accuracy on a relation identification task was highest when fractions were presented with countable sets, whereas accuracy was relatively low for all conditions where decimals were presented. However, it is unclear what processing strategies underlie these disparities in accuracy. We report an experiment that used eye-tracking methods to externalize the strategies that are evoked by different types of rational numbers for different types of quantities (discrete vs. continuous). Results showed that eye-movement behavior during the task was jointly determined by image and number format. Discrete images elicited a counting strategy for both fractions and decimals, but this strategy led to higher accuracy only for fractions. Continuous images encouraged magnitude estimation and comparison, but to a greater degree for decimals than fractions. This strategy led to decreased accuracy for both number formats. By analyzing participants' eye movements when they viewed a relational context and made decisions, we were able to obtain an externalized representation of the strategic choices evoked by different ontological types of entities and different types of rational numbers. Our findings using eye-tracking measures enable us to go beyond previous studies based on accuracy data alone, demonstrating that quantitative properties of images and the different formats for rational numbers jointly influence strategies that generate eye-movement behavior.

  15. A Biologically Realistic Cortical Model of Eye Movement Control in Reading

    Science.gov (United States)

    Heinzle, Jakob; Hepp, Klaus; Martin, Kevan A. C.

    2010-01-01

    Reading is a highly complex task involving a precise integration of vision, attention, saccadic eye movements, and high-level language processing. Although there is a long history of psychological research in reading, it is only recently that imaging studies have identified some neural correlates of reading. Thus, the underlying neural mechanisms…

  16. System and Method for Eye Tracking

    DEFF Research Database (Denmark)

    2017-01-01

    A method and system for monitoring the motion of one or both eyes, includes capturing a sequence of overlapping images of a subject's face including an eye and the corresponding non-eye region; identifying a plurality of keypoints in each image; mapping corresponding keypoints in two or more images...... of the sequence; assigning the keypoints to the eye and to the corresponding non-eye region; calculating individual velocities of the corresponding keypoints in the eye and the corresponding non-eye region to obtain a distribution of velocities; extracting at least one velocity measured for the eye and at least...... one velocity measured for the corresponding non-eye region; calculating the eye-in-head velocity for the eye based upon the measured velocity for the eye and the measured velocity for the corresponding non-eye region; and calculating the eye-in-head position based upon the eye- in-head velocity....

  17. Early caries naked-eyed examination

    International Nuclear Information System (INIS)

    Bakhmutov, D; Gonchukov, S; Voytenok, O; Kharchenko, O; Zubov, B

    2008-01-01

    In view of its potential for dental diagnostics, noninvasive optical methods have been the object of research for the last years. Different techniques (spectroscopy, microscopy, and tomography) are used to discriminate between caries and sound enamel. The main aim of this paper is to determine a simple way to see incipient caries with the naked eye

  18. Degenerative effects in rat eyes after experimental ocular hypertension

    Directory of Open Access Journals (Sweden)

    G. Scarsella

    2012-10-01

    Full Text Available This study was used to evaluate the degenerative effects on the retina and eye-cup sections after experimental induction of acute ocular hypertension on animal models. In particular, vascular events were directly focused in this research in order to assess the vascular remodeling after transient ocular hypertension on rat models. After local anaesthesia by administration of eye drops of 0.4% oxibuprocaine, 16 male adult Wistar rats were injected in the anterior chamber of the right eye with 15 µL of methylcellulose (MTC 2% in physiological solution. The morphology and the vessels of the retina and eye-cup sections were examined in animals sacrificed 72 h after induction of ocular hypertension. In retinal fluorescein angiographies (FAGs, by means of fluorescein isothiocyanate-coniugated dextran (FITC, the radial venules showed enlargements and increased branching, while the arterioles appeared focally thickened. The length and size of actually perfused vessels appeared increased in the whole superficial plexus. In eye-cup sections of MTC-injected animals, in deep plexus and connecting layer there was a bigger increase of vessels than in controls. Moreover, the immunolocalization of astrocytic marker glial fibrillary acidic protein (GFAP revealed its increased expression in internal limiting membrane and ganglion cell layer, as well as its presence in Müller cells. Finally, the pro-angiogenic factor vascular endothelial growth factor (VEGF was found to be especially expressed by neurones of ganglion cell layer, both in control and in MTC-injected eyes. The data obtained in this experimental model on the interactions among glia, vessels and neurons should be useful to evaluate if also in glaucomatous patients the activation of vessel-adjacent glial cells might play key roles in following neuronal dysfunction.

  19. Degenerative effects in rat eyes after experimental ocular hypertension.

    Science.gov (United States)

    Scarsella, G; Nebbioso, M; Stefanini, S; Pescosolido, N

    2012-10-08

    This study was used to evaluate the degenerative effects on the retina and eye-cup sections after experimental induction of acute ocular hypertension on animal models. In particular, vascular events were directly focused in this research in order to assess the vascular remodeling after transient ocular hypertension on rat models. After local anaesthesia by administration of eye drops of 0.4% oxibuprocaine, 16 male adult Wistar rats were injected in the anterior chamber of the right eye with 15 µL of methylcellulose (MTC) 2% in physiological solution. The morphology and the vessels of the retina and eye-cup sections were examined in animals sacrificed 72 h after induction of ocular hypertension. In retinal fluorescein angiographies (FAGs), by means of fluorescein isothiocyanate-coniugated dextran (FITC), the radial venules showed enlargements and increased branching, while the arterioles appeared focally thickened. The length and size of actually perfused vessels appeared increased in the whole superficial plexus. In eye-cup sections of MTC-injected animals, in deep plexus and connecting layer there was a bigger increase of vessels than in controls. Moreover, the immunolocalization of astrocytic marker glial fibrillary acidic protein (GFAP) revealed its increased expression in internal limiting membrane and ganglion cell layer, as well as its presence in Müller cells. Finally, the pro-angiogenic factor vascular endothelial growth factor (VEGF) was found to be especially expressed by neurones of ganglion cell layer, both in control and in MTC-injected eyes. The data obtained in this experimental model on the interactions among glia, vessels and neurons should be useful to evaluate if also in glaucomatous patients the activation of vessel-adjacent glial cells might play key roles in following neuronal dysfunction.

  20. Does the 'P300' speller depend on eye gaze?

    Science.gov (United States)

    Brunner, P.; Joshi, S.; Briskin, S.; Wolpaw, J. R.; Bischof, H.; Schalk, G.

    2010-10-01

    Many people affected by debilitating neuromuscular disorders such as amyotrophic lateral sclerosis, brainstem stroke or spinal cord injury are impaired in their ability to, or are even unable to, communicate. A brain-computer interface (BCI) uses brain signals, rather than muscles, to re-establish communication with the outside world. One particular BCI approach is the so-called 'P300 matrix speller' that was first described by Farwell and Donchin (1988 Electroencephalogr. Clin. Neurophysiol. 70 510-23). It has been widely assumed that this method does not depend on the ability to focus on the desired character, because it was thought that it relies primarily on the P300-evoked potential and minimally, if at all, on other EEG features such as the visual-evoked potential (VEP). This issue is highly relevant for the clinical application of this BCI method, because eye movements may be impaired or lost in the relevant user population. This study investigated the extent to which the performance in a 'P300' speller BCI depends on eye gaze. We evaluated the performance of 17 healthy subjects using a 'P300' matrix speller under two conditions. Under one condition ('letter'), the subjects focused their eye gaze on the intended letter, while under the second condition ('center'), the subjects focused their eye gaze on a fixation cross that was located in the center of the matrix. The results show that the performance of the 'P300' matrix speller in normal subjects depends in considerable measure on gaze direction. They thereby disprove a widespread assumption in BCI research, and suggest that this BCI might function more effectively for people who retain some eye-movement control. The applicability of these findings to people with severe neuromuscular disabilities (particularly in eye-movements) remains to be determined.